Specifications for Rotating Anode X-ray Tube Ass y. Model : M125S20X. Maximum X-ray Tube Voltage kV. Focal Spot Size (Small/Large) /2.

Size: px
Start display at page:

Download "Specifications for Rotating Anode X-ray Tube Ass y. Model : M125S20X. Maximum X-ray Tube Voltage kV. Focal Spot Size (Small/Large) /2."

Transcription

1 Specifications for Rotating Anode X-ray Tube Ass y Model : Maximum X-ray Tube Voltage kV Focal Spot Size (Small/Large) /2.0mm Anode Heat Content kJ(140kHU) X-ray Tube Ass y Heat Content kJ(1,250kHU) Min. Anode Rotation Speed(60Hz)... Min. 3,200rpm DOC no Date Rev RD

2 GENERAL SPECIFICATION 1. Product Information 1.1 Short Description Intended use: X-ray tube assembly with double-focus rotating anode X-ray tube is intended to be used for diagnostic X-ray equipment. 125kV, 140kHU rotating anode insert tube which is designed for general radiographic procedures. - Tungsten-rhenium alloy faced TZM target of 16º and 74mm diameter - Available in the 1.0mm / 2.0mm focal spot combinations - Stator of min. 3200rpm rotation speed 900kJ heat content of X-ray tube ass y Accommodated with IEC60526 type high voltage cable receptacles. 1.2 Designation of each part of tube assembly Page 2

3 2. General Data 2.1 Electrical Data Nominal X-ray Tube Voltage kv Operating X-ray Tube Voltage kV Nominal Focal Spot Size Large mm Small mm Anode Rotating Speed 50Hz... Min. 2,700 rpm 60Hz... Min. 3,200 rpm Stator Resistance Main Winding Ω Auxiliary Winding Ω Stator Capacitor μf Resistance Between Housing and Low Voltage Terminals... Min. 2 MΩ Nominal Anode Input Power Focus 50 Hz 60 Hz Large 43 kw 47 kw Small 21 kw 22.5 kw Normal Housing Operating Temperature Page 3

4 2.2 Mechanical Data Overall length mm Detail Dimensions... See page 8 Approximate Weight kg Target Diameter mm Anode Angle degree Material... Tungsten-Rhenium faced TZM Filtration Permanent Filtration mm Al / 75 kv Radiation Protection Leakage Technique Factor kv, 4 ma X-ray Coverage (at SID 750 mm ) mm High Voltage Receptacle... To meet requirements of IEC60526 Cooling Method... Natural air 2.3 Environmental Limits Operating Limits Temperature Humidity % Atmospheric Pressure kpa Shipping and Storage Limits Temperature Humidity % Atmospheric Pressure kpa Page 4

5 3. Max. and Min. Ratings (Maximum Design Value) Max. X-ray Tube Voltage kv Max. Voltage to Ground kv Min. X-ray Tube Voltage kv Max X-ray Tube Current Large ma Small ma Max. Filament Current A Filament Voltage (at max. filament current 5.1A) Large V Small V Filament Frequency Limits khz Thermal Characteristics Anode Heat Content kj (140 khu) Max. Anode Heat Dissipation W (667 HU/s) X-ray Tube Ass y Heat Content kj (1250 khu Max. Continuous Heat Dissipation Without Air-circulator W (15 khu/min) Page 5

6 4. Max. Rating Charts 4.1 Stator Frequency : 60 Hz [Focal Spot : 1.0mm ] [Focal Spot : 2.0mm ] Tube Current ( ma ) 70kV 60kV 50kV kV 90kV 40kV kV kV 125kV Tube Current ( ma ) 100kV kV 80kV 70kV 60kV 50kV 110kV kV 125kV Exposure Time (sec) Exposure Time (sec) 4.2 Stator Frequency : 50 Hz [Focal Spot : 1.0 mm ] [Focal Spot : 2.0 mm ] kV 60kV 50kV kV 80kV 70kV 60kV 50kV kV 90kV 40kV kV 110kV 40kV Tube Current ( ma ) kV 110kV 125kV Tube Current ( ma ) kV Exposure Time (sec) Exposure Time (sec) Page 6

7 5. Emission and Filament Characteristics 5.1 Focal Spot : 2.0 mm Tube Current ( ma ) Filament Voltage (V) Filament Current (A) 5.2 Focal Spot : 1.0 mm Tube Current ( ma ) Filament Voltage (V) Filament Current (A) Page 7

8 6. Thermal Characteristics 6.1 Anode Heating and Cooling Curves Heat Storage (kj) Time (minutes) 6.2 X-ray Tube Ass y Heating and Cooling Curve Heat Storage (kj) Time (minutes) Page 8

9 7. Detail Dimensions [Unit : mm ] Anode Central Ray and Reference Axis Large Small Cathode Common Central X-ray Terminal Connections E Focal Spot A A : ±1.5 mm, B : ±1.5 mm Center of Focal Spot B Non-connection Temperature Relay (Normally Closed) C M A C : Common M : Main Winding of the Stator A : Auxiliary Winding of the Stator Earth Terminal Non-connection [Note] Do not connect terminal No.1 and No.5 or 6 in series circuit. Page 9

10 8. Symbols 8.1 Symbols marked on Symbol Description CE Marking of Conformity Serial Number: This symbol means serial number of product. Manufacturer information: The manufacturer s information shows with this symbol. Made Date: The made date of the product shows with this symbol Protective earth symbol: This symbol means Protective earth terminal Representatives information: The manufacturer s EU representative information shows with this symbol.! Warning or Caution: This symbol indicates hazard. Electronics Disposal Information: This symbol means that the product should be recycled separately from household waste. When this product reaches its end of life, follow the local laws and regulations of disposal. The improper disposal of waste electronic equipment from the consumer may be subject to fines. Page 10

11 8.2 Symbols on the Packaging of Symbol Description KEEP DRY: This symbol means keep away from Rain Fragile : This symbol means do not drop of product. UP: This symbol means "This way up". Page 11

12 9. Label Location 9.1 Front Page 12

13 9. Label Location 9.2 Rear Page 13

14 10. Cautions 1) Caution for Installation, Adjustment and Maintenance Qualified Persons : Only qualified persons who have technical training and professional knowledge can handle X-ray tube assembly. Fragile Glass : X-ray tube is assembled with glass, therefore, it can be broken with the mechanical vibration or pulsed shock over 19.6m/(2G). Careful handling is required to treat or transport. Ground Terminal : X-ray tube assembly has ground terminal. Ground cable should be connected. High Voltage : All X-ray tubes operate at voltages high enough to kill through electric shock. Never touch the high voltage delivered plugs or terminals. When direct access to such parts is required, the primary circuit should be disabled and high voltage capacitors/cables discharged. High Voltage Plug : High voltage plug should be cleaned up and free from any physical damages. Silicon compound application is required for high voltage stability. Rotating Anode - Test rotation of the anode with the large focus filament at the preheat condition. At this time, do not supply the tube voltage. - When the hand switch READY button is pressed, the filament will become brighter and the anode target will start rotating. The anode for normal speed will reach the predetermined number of revolution in 0.4 to 1 sec., and it will continue rotation for some time after the stator drive input is cut off. The anode for high speed shall be automatically braked to reduce speed and continue coasting after the drive input to the stator is cut off. - Ensure that the anode target rotates in the proper direction. X-ray tube should always rotate counter-clockwise, viewing from the cathode side. Operation Atmosphere : X-ray tube assembly is not allowed to use in the atmosphere of flammable or corrosive gas. Protective Cover : X-ray tube assembly is not allowed to use without the protective cover Handling : Appropriate jigs or tools are required for tube installation to avoid physical damages. Returning Tube : X-ray tube assembly should be repacked with the original material when it is returned back for quality examination in our factory. Be careful to put the tube upside cathode. If the packaging is not proper, the tube may not be correctly examined. Page 14

15 2) Caution to interface with X-ray Generator Over Rating : X-ray tube assembly can be broken with applying just one over rated shot. Please read the specification sheets carefully and follow the instructions. Permanent Filtration : The total filtration and the distance between X-ray focal spot and human body are regulated legally. They should be complied with the regulation. Safety Thermal Switch : X-ray tube assembly has safety thermal switch to prohibit further input power when the tube housing reaches to the temperature of switch-open. The switch should be hooked up with the X-ray generator which control output power to X-ray tube assembly. The switch is not recommended connecting stator coil in series circuit. Even if the switch works, never turn the system power off. The cooling unit should be activated if used with the system. Safety Plate : The Safety Plate is mounted on anode housing wall. When external cover is removed, it is visibly recognized as labeled with label 8 in Caution Labels page. Followings are important notice of the Safety Plate: - Function : When housing inner pressure reaches to the working pressure of the Safety Plate, the Safety Plate collapses and vaporized oil and hot oil flow through the collapsed Safety Plate. The external cover can protect the initial impact of oil flow, however, it can not protect oil drop or oil leakage. - Caution : Never touch the Safety Plate or remove the label and the screws. Otherwise, it could cause collapse of Safety Plate. Please note the Safety Plate is not the device to protect X-ray tube from destruction when over-rated power input but just to reduce the impact of housing rupture. Unexpected Malfunction : X-ray tube assembly may have the risk to be unexpectedly malfunctioning due to life termination or failure. If the serious problems caused by the above risk are expected, you are requested to have a contingency plan to avoid such a case. New Application : If you use the product with new application not to be mentioned in this specification or with different type of X-ray generator, please contact to us for confirming its availability. Page 15

16 3) Periodical Inspection To maintain long-time stable operation and service life, perform the periodical inspection at every regular intervals (at least once a year) in accordance with the items described on the following page. For any inspection items, if necessary, instruct LUCEM Co.. Ltd. personnel to carry out the periodical always operation the silicone compound may become dry, the coated state changed or the withstand voltage performance degraded. Insulation oil leakage from tube housing Thermal switch operation of the tube assembly High voltage cable connection part - Looseness of cable plug camping part - Silicone compound leakage and state of coating Roughness and bulb spatter on the target surface of the X-ray tube. Extremely abnormal noise and or vibration due to X-ray tube anode rotation Abnormal rotation of the air circulator of the tube assembly. Grounding wire and grounding resistance. Indication of tube voltage meter, tube current meter, and other meters. Timing phase deviation and time accuracy of the exposure timer. Operation of the starter for the tube assembly. Brightness and image quality of X-ray image intensifier. 4) Others X-ray tube ass y should have the -ray X limiting equipment mounted on the X-ray port to protect unnecessary radiation. X-ray tube ass y is not allowed is not allowed to use in the atmosphere of flammable or corrosive gas. If the input power exceeds X-ray tube ass`y specification, it cause the over temperature of anode, insert tube glass shatter, housing sealing parts rupture, human injury including burns due to hot oil escape and fire accident due to flaming anode target. The X-ray generator should have a protective function which manages input power to be within X-ray tube ass y specification. X-ray tube ass y is covered with lead inside tube housing to protect unnecessary radiation. The lead is harmful for human health. Dispose the scrapped products according to the requirement of local regulation. Page 16

17 X-ray tube ass y has insulation oil contained for high voltage stability. The insulation oil is poisonous for human health. If it is exposed to the non-restricted area, it should be disposed as following to the local regulation. According to the operating conditions, the filament characteristics might be changed to lead to the over rate exposure to X-ray tube ass y. To prevent the X-ray tube ass y from being damaged, please adjust the tube current regularly. Please don t touch on X-ray tube ass y just after operation due to high temperature. X-ray tube assembly is not allowed to lift more than 1 meter during transportation. X-ray tube assembly is not allowed to stack more than 2 stories. If any malfunction of the X-ray tube ass y is noticed, please contact to us immediately. Avoid fire and explosion hazard. An explosion hazard may result from the use of flammable anesthetics, skin cleansing agents and disinfectants. When cleaning the device, pay special attention so that cleaning liquid or any liquid may not soak into the inside of device. If any liquid soak into the inside of device, do not connect power line, do not use device, and contact service center. This equipment produces ionizing radiation. Observe proper safety practices during operation. The requirement to wear personal protective equipment such as lead aprons, dosimetry badges etc is governed by individual states and may vary from state to state. Other safety information follows the product-mounting system information. The tube assembly contains a high-vacuum product that can implode on incorrect handling, such as by impact, striking, dropping down. Use of the X-ray tube assembly is forbidden if signs of mechanical, electrical or radiation-related defects are present. WARNING: To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth. Page 17

Voltage nominal maximum for test. Inverse voltage. nominal maximum for test. Focal spots (IEC 60336:2005) small large

Voltage nominal maximum for test. Inverse voltage. nominal maximum for test. Focal spots (IEC 60336:2005) small large TECHNICAL DATA GENERAL INFORMATIONS Voltage nominal maximum for test 1 135 kv When mounting tube inserts adopt proper caution, in order to avoid glass bulb breaking and fragments projection. Please use

More information

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the discussion on the major components of the x-ray machine. Today

More information

X-ray Imaging Systems

X-ray Imaging Systems Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures

More information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall

More information

X-ray Imaging Systems

X-ray Imaging Systems Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures

More information

MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W

MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the

More information

UV100A Ultraviolet Air Treatment System

UV100A Ultraviolet Air Treatment System UV100A Ultraviolet Air Treatment System INSTALLATION INSTRUCTIONS APPLICATION When installed in forced air heating and cooling systems, the UV100A Ultraviolet Air Treatment System kills airborne microorganism

More information

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual

More information

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase User s Guide Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase of the FLAVORCHEF cooking system, which will provide you with healthy and tasty meals for

More information

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018 USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and

More information

Spec. No. ICR18650-26C Version No. 0.0

Spec. No. ICR18650-26C Version No. 0.0 1. Scope This product specification has been prepared to specify the rechargeable lithium-ion cell 2. Description and Model 2.1 Description Cell (lithium-ion rechargeable cell) 2.2 Model ICR18650-26C 3.

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual Instruction Manual Option Card for Frequency Divider Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual and understand the description

More information

WSD130 SOLDERING STATION

WSD130 SOLDERING STATION NOTES S2032ACH 8/98 Rev. 11/01 WSD130 SOLDERING STATION 1. Power Switch 2. Digital Display 3. UP Button 4. DOWN Button 5. Optical Regulator, Right 6. Connection for Soldering Iron, Right 7. Selection Switch

More information

AIR-CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY DIAGNOSTIC (VETERINARY) SECTION 1:

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

=============================== WARNING

=============================== WARNING =============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that

More information

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

15GAL STEEL OIL DRAIN WITH 110V PUMP

15GAL STEEL OIL DRAIN WITH 110V PUMP 15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

How To Use A Power Supply Unit (Upu)

How To Use A Power Supply Unit (Upu) BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING PLEASE READ AND SAVE THESE INSTRUCTIONS - 2 - INTRODUCTION TO THE BIG

More information

Infrarot-Bewegungsmelder IP44

Infrarot-Bewegungsmelder IP44 Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion

More information

Ultrasonic support removal tank

Ultrasonic support removal tank Ultrasonic support removal tank User guide and safety manual See inside for use and safety information. The Ultrasonic support removal tank automatically removes PLA support material from a printed ABS

More information

3 WATT LED SPOTLIGHT Model No. SLM - 3801

3 WATT LED SPOTLIGHT Model No. SLM - 3801 3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging

More information

Model 1756 Test Lead Kit

Model 1756 Test Lead Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you

More information

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important

More information

Specification Approval Sheet

Specification Approval Sheet GUANGZHOU MARKYN BATTERY CO., LTD. Specification Approval Sheet FOR LIPO BATTERY Product Name Model SPEC Company Name Document Number Li-ion Polymer Battery 062025/250mAh/3.7V GMB POWER GMB1102150615 Sample

More information

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

12V Portable Diaphragm Compressor Operating and Maintenance Instructions 12V Portable Diaphragm Compressor Operating and Maintenance Instructions (Part No. DC2) Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Guidelines for Product Use...2 Operation

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

Installation and safety instructions for AC/DC built-in devices

Installation and safety instructions for AC/DC built-in devices The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further

More information

National- Spencer Inc.

National- Spencer Inc. 9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum

More information

LITHIUM BATTERY CR123A SPECIFICATION

LITHIUM BATTERY CR123A SPECIFICATION LITHIUM BATTERY CR123A SPECIFICATION Date: April 24, 2012 Approved by: Scotty Scott PANASONIC ENERGY CORPORATION OF AMERICA LITHIUM BATTERY DIVISION 1. Designation : CR123A 2. Nominal Voltage : 3 V 3.

More information

Kolorlux. GE Lighting DATA SHEET

Kolorlux. GE Lighting DATA SHEET GE Lighting Kolorlux High pressure Mercury lamps Kolorlux Standard 50W, 80W, 125W, 250W and 400W Kolorlux Deluxe 50W, 80W, 125W, 250W and 400W DATA SHEET Product information Kolorlux Mercury vapor lamps

More information

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC. BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1 UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping

More information

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE m Before Use Please read IMPORTANT SAFETY INSTRUCTIONS on page 10 before use. It is important

More information

Achat 115MA full-range speaker. user manual

Achat 115MA full-range speaker. user manual Achat 115MA full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION: Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do

More information

Operating Instructions Bedienungsanleitung Mode d emploi

Operating Instructions Bedienungsanleitung Mode d emploi Operating Instructions Bedienungsanleitung Mode d emploi DW 400 www.bron-kobold.com Operating instructions DW 400 Before use Please read all the information contained in these operating instructions carefully.

More information

User s Manual AURORA 1.2K/2.2K

User s Manual AURORA 1.2K/2.2K User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable

More information

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1 No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

VACUUM CLEANER INSTRUCTION MANUAL

VACUUM CLEANER INSTRUCTION MANUAL VACUUM CLEANER INSTRUCTION MANUAL MODEL: SVC9702 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING AND KEEP IT PROPERLY FOR FUTURE USE 1 Safety Cautions: WARNING: To reduce the risk of fire, electrical shock,

More information

1. Scope This specification is applied to ICR18650. 2. Product Specification Table 1 No. Item Rated Performance Remark

1. Scope This specification is applied to ICR18650. 2. Product Specification Table 1 No. Item Rated Performance Remark 1. Scope This specification is applied to ICR18650. 2. Product Specification Table 1 No. Item Rated Performance Remark 1 Rated Capacity Typical Minimum 2 Nominal Voltage 3.7V 3 Voltage at end of Discharge

More information

CELO5. User & Installation Manual. www.audac.eu

CELO5. User & Installation Manual. www.audac.eu CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt

More information

Pet hair clipper. Model 96822. Diagrams within this manual may not be drawn proportionally.

Pet hair clipper. Model 96822. Diagrams within this manual may not be drawn proportionally. Pet hair clipper Model 96822 Cleaning And Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the

More information

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR

More information

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MOBILE RADIOGRAPHY)

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

SMD Rework Station TABLE OF CONTENTS

SMD Rework Station TABLE OF CONTENTS SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating

More information

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger. Battery-Powered Mower NEUTON 24-Volt Charger Instructions Booklet Dear Neuton Owner, In order for you to get the most out of your Neuton Mower, we recently reviewed and revised our battery-charging instructions.

More information

EVERGREEN (C.P.) USA INC. TEL: (650) 952-8091 FAX: (650) 952-3629 E-MAIL: sales@evergreencpusa.com. SPECIFICATIONS Lithium Battery CR123A- 1700mAh

EVERGREEN (C.P.) USA INC. TEL: (650) 952-8091 FAX: (650) 952-3629 E-MAIL: sales@evergreencpusa.com. SPECIFICATIONS Lithium Battery CR123A- 1700mAh Voltage (V) Voltage (V) Voltage (V) EVERGREEN (C.P.) USA INC. SPECIFICATIONS Lithium Battery CR123A- 1700mAh Temperature characteristics(20ma) (mah) Pulse discharge characteristics Model CR123A Nominal

More information

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual A Regal Brand TABLE OF CONTENTS INTRODUCTION 2 General Data 2 Initial Inspection 2 SAFETY 2 INSTALLATION 3 Location / Environment

More information

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly

More information

aseries A13B Mini Bullet Camera User Manual

aseries A13B Mini Bullet Camera User Manual aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView

More information

Power supply unit Model: PAC-SC50KUA

Power supply unit Model: PAC-SC50KUA Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.

More information

Single Phase Soft Starter

Single Phase Soft Starter Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (BIOPSY) SECTION

More information

Li Battery Pack & Charger Safety & Operating Instructions

Li Battery Pack & Charger Safety & Operating Instructions Li Battery Pack & Charger Safety & Operating Instructions NEUTON Power Equipment 75 Meigs Road Vergennes, VT 05491 Toll-Free phone: 1-866-NEUTON1 (638-8661) Fax: 1-802-877-1213 Website: www.neutonpower.com

More information

804 Ti Stand. Manual 8.804.8001EN

804 Ti Stand. Manual 8.804.8001EN 804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware

More information

Lithium Ion Battery Specifications

Lithium Ion Battery Specifications Lithium Ion Battery Specifications Type: Cylindrical Lithium Iron Phosphate Battery Mode: LFP-26650-3300 AA Portable Power Corp. Prepared by Checked by Approved by 1 . Product Specifications Type ------------

More information

V94 BULK TAPE DEGAUSSER

V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Operating and Maintenance Instructions for V94 BULK TAPE DEGAUSSER V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Document No. M000208 Production Standard ZZ 009 415 WARNING To help minimise

More information

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

NOTE: Additional user information for your printer may be available in the Manuals section at support.dell.com. CAUTION: General Safety Instructions Use the following safety guidelines to help ensure your own personal safety and to help protect your equipment and working environment from potential damage. NOTE:

More information

li-ion Polymer Battery Specification

li-ion Polymer Battery Specification Customer: li-ion Polymer Battery Specification MODEL: GMB042035 Prepared By/Date Checked By/Date Approved By/Date Note:1.Kindly please sign on the above and send it back to us if the sample is approved.

More information

Rexroth Hydraulic Pump A10VO Series User Manual

Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MOBILE RADIOSCOPY)

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

Antenna Splitter ASA 1. Instruction manual

Antenna Splitter ASA 1. Instruction manual Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...

More information

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified

More information

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Wine Cooler with Thermo-Electric Cooling & Heating Technology Wine Cooler with Thermo-Electric Cooling & Heating Technology Model number: WC-0888H (8-bottles capacity) Instruction Manual Please read carefully and follow all safety rules and operating instructions.

More information

Achat 208 HL / 208 HR passive mid-range speaker. user manual

Achat 208 HL / 208 HR passive mid-range speaker. user manual Achat 208 HL / 208 HR passive mid-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet:

More information

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent

More information

Seven function digital multimeter

Seven function digital multimeter Seven function digital multimeter 98025 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com

More information

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR CAUTION! Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR NOTE: read the manual prior to commencement of use. For safety reasons, the pump can only be operated by

More information

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in

More information

AC-DC Converter Application Guidelines

AC-DC Converter Application Guidelines AC-DC Converter Application Guidelines 1. Foreword The following guidelines should be carefully read prior to converter use. Improper use may result in the risk of electric shock, damaging the converter,

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

GF SERIES 1-TANK/2-TANK ELECTRIC FRYER USER S MANUAL

GF SERIES 1-TANK/2-TANK ELECTRIC FRYER USER S MANUAL GF SERIES 1-TANK/2-TANK ELECTRIC FRYER USER S MANUAL Thank you for purchasing and using GF series Electric Fryer. In order to make full use of functions of this product and minimize unnecessary loss and

More information

Single-Phase AC Synchronous Generator

Single-Phase AC Synchronous Generator ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

Mounting Instructions. Torque Transducer. A0329 3.2 en

Mounting Instructions. Torque Transducer. A0329 3.2 en Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................

More information

Cisco TelePresence MCU 4500 Series safety and compliance information

Cisco TelePresence MCU 4500 Series safety and compliance information Cisco TelePresence MCU 4500 Series safety and compliance information On this page: Safety information symbols Operating guidelines Safety warnings Technical specifications Compliance information WEEE information

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Wood pellet and biomass system ceramic igniter

Wood pellet and biomass system ceramic igniter Wood pellet and biomass system ceramic igniter Specification Data Product name: Ceramic Igniter PSx-2-120-W Drawing number: IBA-HH020A Revised on: 2015.12.20 1. Application This engineering specification

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

UT202A Operating Manual. Contents

UT202A Operating Manual. Contents Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into

More information

19 LED Tube Controller ORDERCODE 41003

19 LED Tube Controller ORDERCODE 41003 19 LED Tube Controller ORDERCODE 41003 Congratulations! You have bought a great, innovative product from Showtec. The Showtec 19 LED Tube Controller brings excitement to any venue. Whether you want simple

More information

Specification of 5 Wire Analog Touch Panel

Specification of 5 Wire Analog Touch Panel Specification of 5 Wire Analog Touch Panel 5 WIRE ANALOG RESISTIVE TOUCH PANEL A. Application This specification applies to the 5 Wire Analog Resistive Touch Panel. B. Environmental Conditions 1. Operating

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3 2 Phase Stepping Motor Driver 2M542 OPEATING MANUAL Table of contents Introduction page 2 Specifications page 2 Timing chart page 3 Setting page 4 Current set page 4 educe current function page 4 Micro

More information