1 Dell EqualLogic Multipathing Extension Module Installation and User Guide Version 1.1 For vsphere Version 5.0
2 Copyright 2011 Dell Inc. All rights reserved. EqualLogic is a registered trademark of Dell Inc. Dell is a trademark of Dell Inc. All trademarks and registered trademarks mentioned herein are the property of their respective owners. Information in this document is subject to change without notice. Reproduction in any manner whatsoever without the written permission of Dell is strictly forbidden. November 2011 Part Number: EN-R2
3 Table of Contents 1 Overview 1 EqualLogic MEM Architecture 1 EqualLogic MEM Configuration Model 2 Related Documentation 3 2 Installing the EqualLogic MEM 5 Obtaining the EqualLogic Multipathing Extension Module 5 Software iscsi Configuration Requirements 5 Using the Setup Script for Network Configuration 7 Configuring Your Network for the MEM Plugin 7 Installation Considerations 9 Installing Or Upgrading the EqualLogic MEM On Your VMware ESXi Host 9 Verifying the Installation 11 Enabling and Disabling the EqualLogic Plugin 12 Using the EqualLogic MEM With AutoDeploy 12 3 Configuring the EqualLogic MEM 15 EHCM Configuration 15 EHCM Configuration File 15 EqualLogic MEM Configuration Using ESX CLI Commands 15 EqualLogic MEM Configuration Using Host Profiles 18 4 Troubleshooting 19 Log Files 19 Troubleshooting Common Issues 19 A Sample Configuration Commands 21 Configuring a 4-Port Nic Using the VMware Software iscsi Initiator 21 Configuring a Two-Port Broadcom Enabled For iscsi Offload 22 B Technical Support and Customer Service 25 Online Services 25 Index 27 iii
4
5 1 Overview VMware vsphere provides the Pluggable Storage Architecture (PSA), which enables you to configure multipathing for high availability and increased performance. The modular design of the architecture accepts third-party multipathing plugins that enable enhanced functionality specific to storage device models. The EqualLogic Multipathing Extension Module (MEM) provides the following enhancements to the existing VMware multipathing functionality: Automatic connection management Automatic load balancing across multiple active paths Increased bandwidth Reduced network latency EqualLogic MEM Architecture The EqualLogic Multipathing Extension Module consists of: The EqualLogic kernel mode Path Selection Plugin (PSP) driver A kernel mode plugin that is used by the VMware Native Multipathing Plugin (NMP) to select the best path for each I/O to EqualLogic storage devices. The EqualLogic Host Connection Manager (EHCM) A user mode process that runs in a CIM provider and manages the iscsi sessions to EqualLogic storage devices. The PSP provides load balancing capabilities that enable you to maximize I/O throughput. The PSP uses its knowledge of the distributed nature of volumes on the PS Series group to route each I/O packet on the optimal path to the volume. EHCM simplifies management by creating the appropriate number of sessions to an EqualLogic volume. The number of paths created by EHCM depends on the topology of your SAN and the MPIO settings on the VMware ESXi host. Every volume is distributed across one or more members in the PS Series group. The portion of a volume that is located on a single member is referred to as a volume slice. The default EHCM behavior is to create two sessions per volume slice, with a maximum of six sessions per volume. However, you can alter this behavior (see EHCM Configuration File on page 15). When you use the EqualLogic MEM, EHCM distributes iscsi sessions across all configured adapters and PS Series group Ethernet ports. EHCM does not establish entirely redundant paths (iscsi sessions that have identical server and array endpoints). Therefore, in configurations that have limited numbers of VMware ESXi and array Ethernet ports, the actual number of sessions created may be less than you specify for the configuration. EHCM monitors the topology of the SAN. If you change the configuration by modifying the number of Ethernet interfaces, or by moving a PS Series volume, or if there is a network outage that affects some of the iscsi sessions, EHCM automatically reconfigures the iscsi sessions. 1
6 EqualLogic MEM Installation and User Guide 1 Overview EqualLogic MEM Configuration Model Figure 1 shows the logical path configuration used by the EqualLogic MEM. Figure 1: EqualLogic MEM Logical Path Configuration Table 1 describes the components shown in this figure. Callout Table 1: EqualLogic MEM Logical Path Configuration Details Description 1 VMware virtual machines with guest operating system 2 Virtual machine disk format (VMDK) 3 Raw device mapping (RDM) disk 4 VMware file system (VMFS) 5 CIM provider, which hosts EqualLogic Host Connection Management 6 EqualLogic Routed PSP 7 VMware native multipathing, hosting the PSP driver 8 VMkernel, the ESX hypervisor, including network and storage stacks 9 Host Bus Adapter (HBA) or software initiator 10 Network 11 PS Series group members 2
7 EqualLogic MEM Installation and User Guide 1 Overview Related Documentation It is beyond the scope of this document to provide VMware conceptual information or detailed instructions on configuring VMware vsphere. See the following related documentation. VMware Documentation See the VMware documentation web site: Specifically, refer to the following documents: Installing and Administering vsphere Update Manager vsphere Installation and Setup Guide iscsi SAN Configuration Guide Dell EqualLogic Tech Report For information about the benefits of the Dell Multipathing Extension Module, see the Dell EqualLogic technical report number 1074, entitled Configuring and Installing the EqualLogic Multipathing Extension Module for VMware vsphere 5.0 and PS Series SANs. This report is available in the Tech Reports section under Resources on the Dell EqualLogic customer support site. 3
8
9 2 Installing the EqualLogic MEM Installation topics for the EqualLogic Multipathing Extension Module include the following: Obtaining the EqualLogic Multipathing Extension Module on page 5 Software iscsi Configuration Requirements on page 5 Using the Setup Script for Network Configuration on page 7 Configuring Your Network for the MEM Plugin on page 7 Installation Considerations on page 9 Tasks Performed During the Installation Process on page 1 Installing Or Upgrading the EqualLogic MEM On Your VMware ESXi Host on page 9 Removing the EqualLogic Plugin on page 11 Verifying the Installation on page 11 Enabling and Disabling the EqualLogic Plugin on page 12 Using the EqualLogic MEM With AutoDeploy on page 12 See the Dell EqualLogic Multipathing Extension Module Release Notes for installation requirements and information, including: Minimum software and firmware prerequisites Unsupported VMware environments Notes about using the EqualLogic plugin with HBAs Obtaining the EqualLogic Multipathing Extension Module The EqualLogic MEM is available from the Technical Support website, packaged as a zip file. The zip file has the following contents: setup.pl A configuration script. To use this script, copy it to a vsphere CLI or vsphere Management Assistant (vma) v.5.0. dell-eql-mem-<version>.zip The offline VMware Infrastructure Bundle (VIB) to be installed on an ESX server. This bundle should not be unzipped, as the installation tools expect it in.zip format. This bundle can be installed through vcenter Update Manager or from a vma with the ESX CLI command esxcli software vib install. Software iscsi Configuration Requirements Before you can use the EqualLogic MEM, you must configure VMware ESX iscsi networking on your server. You must ensure that you complete the configuration tasks identified in Table 2. 5
10 EqualLogic MEM Installation and User Guide 2 Installing the EqualLogic MEM EqualLogic has provided a configuration tool to automate this process. See Configuring Your Network for the MEM Plugin on page 7. Table 2: Software iscsi Configuration Requirements Task Action Description 1 Create a vswitch 2 Enable jumbo frames Create a vswitch to use for iscsi traffic. Assign physical NICs that will be used for iscsi traffic to this vswitch. If you intend to use jumbo frames, you must enable them for each vswitch and each VMkernel port (virtual network interface that is used by the VMkernel) interface. You must use the command line to create a VMkernel port with jumbo frames enabled. You can verify that jumbo frames are enabled on the vswitch and VMkernel ports by using the commands esxcfg-vswitch -l and esxcfg-vmknic -l. 3 Decide on VMkernel ports 4 Create VMkernel ports 5 Remove extra uplinks 6 Enable VMware iscsi Initiator 7 Bind the VMkernel ports Before enabling Jumbo Frames, check with your hardware vendors to ensure your physical network adapter and other network equipment support Jumbo Frames. For MPIO, the iscsi daemon uses the VMkernel ports. You can have ports on multiple vswitches, but each port must be mapped to a single uplink. Create VMkernel ports for the iscsi daemon to use. You should create one VMkernel port per physical NIC that will be used for iscsi multipathing. If you have multiple VMkernel ports sharing the same uplink, only one of them will be used by EHCM, and the excess VMkernel ports will be ignored. You can use multiple NICs per vswitch, but each VMkernel port must be mapped to a single uplink (physical NIC). You can verify this by using the command esxcfg-vswitch -l, and you can remove extra uplinks with the esxcfg-vswitch -N command. Enable VMware iscsi Initiator. You must add the PS Series group address to the iscsi Initiator discovery list. You must bind the VMkernel ports to the iscsi daemon with the esxcli iscsi networkportal add command. It is necessary to rescan for storage devices after you bind VMkernel ports to the iscsi daemon. See the Setting Up Software iscsi Initiators section in the iscsi SAN Configuration Guide.The VMware vsphere ESX 5.0 documentation is available at this website: 6
11 EqualLogic MEM Installation and User Guide 2 Installing the EqualLogic MEM Note: See the PS Series documentation for group limits on total iscsi sessions. It may be necessary to reduce the number of sessions created per volume in large configuration. Using the Setup Script for Network Configuration The Dell EqualLogic installation script setup.pl can be used for network configuration operations. Prerequisites for setup.pl Script The setup.pl script is designed to be run from the VMware Management Assistant (vma) virtual appliance. It can also be run from a Linux or Windows host that has the vsphere CLI 5.0 installed. Older versions of the vsphere CLI are not supported. Note: Dell recommends that you configure vi-fastpass on the vma. Once vi-fastpass is configured, it is not necessary to specify the username and password when running the setup script, though it is still necessary to identify the ESX server. See the vsphere Management Assistant Guide, available from VMware, for more details on configuring vi-fastpass authentication. Table 3 describes the setup.pl script parameters that are common to multiple operations. Parameter --server --username --password --vihost --viusername --vipassword --chapuser --chapsecret Table 3: Commonly Used Parameters with the setup.pl Script Description ESX/ESXi host or vcenter server on which to run the command. Administrative user account on host. Not necessary if running on a VMA with vi-fastpass configured. Password for administrative account on host. Not necessary if running on a VMA with vi-fastpass configured. To install on an ESXi host, it must be configured with an administrative password. ESX/ESXi host. This parameter is required if --server refers to a vcenter server. Administrative user account for the vihost. Not necessary if running on a vma with vi-fastpass configured. Password for administrative account for the vihost. Not necessary if running on a vma with vi-fastpass configured. CHAP user name to be used for connecting volumes on the PS Series group IP. CHAP secret to be used for connecting volumes on the PS Series group IP. Configuring Your Network for the MEM Plugin Use the following syntax to configure your network for the EqualLogic MEM plugin: setup.pl --configure --server="hostname" [--username= username ] [--password=password] --nics=nic1,nic2,... --ips=ip1,ip2,... 7
12 EqualLogic MEM Installation and User Guide 2 Installing the EqualLogic MEM [--vswitch=vswitchname] [--mtu=mtu] [--vmkernel=vmkernel_prefix ] [--netmask=subnet_mask] [--enableswiscsi] [--nohwiscsi] [--groupid=ps group IP] [--vds] [--logfile] [--heartbeat] Table 4 describes the configuration parameters. Table 4: Parameters for Configuration Parameter Description Default --nics --ips --vswitch --mtu --vmkernel --netmask --enableswiscsi --nohwiscsi --groupip --vds --logfile --heartbeat Comma separated list of vmnics to use for none multipathing. Comma separated list of IP addresses to assign to none VMkernel ports used for multipathing. Name of vswitch to create. Will use existing vswitchiscsi vswitch if one is found. MTU to use for VMkernel ports and vswitch used 1500 for multipathing. Prefix to use for VMkernel ports created for iscsi multipathing. Subnet mask used for VMkernel ports created for multipathing. Enable the VMware software iscsi initiator if not not set already enabled. Ignore any supported hardware adapters, and use only the VMware software iscsi initiator. If the configuration script detects both software and not set hardware initiators, it will use the hardware initiator by default unless this flag is set. Sets the specified IP address as a Send Targets discovery address for all iscsi initiators that were none used to bind vmknics. Use a vnetwork Distributed Switch instead of a not set standard vswitch. Specify a file to use ro record a log of network setup.log configuration actions. IP address to use for a highly available VMkernel port on the iscsi subnet. This VMkernel port will be configured to use all physical NICs on the none vswitch, so it will remain online in the event of a single NIC failure. Note: The --configure operation can be run in an interactive mode by specifying only the server name parameter. The script then interactively asks the user a series of questions to gather the necessary information for network configuration. For example: setup.pl --configure --server= xxxx.xxx 8
13 EqualLogic MEM Installation and User Guide 2 Installing the EqualLogic MEM Installation Considerations Installation of the EqualLogic MEM requires you to put the ESXi host in maintenance mode using VMware management tools. Configuration through the setup.pl script requires connecting directly to the ESXi host. For ESXi hosts this requires you to disable lockdown mode. Because installation requires putting the ESXi host in maintenance mode, it is not possible to perform the installation from a vcenter Server, vcenter Update Manager, or VMware Management Assistant that is running as a VM on the ESXi host. The VMs must first be migrated to another ESXi host so they can continue running during the installation. For a clean installation of MEM on ESXi, you do not need to reboot ESXi. However, if you upgrade or uninstall MEM, you must reboot the ESXi host for the changes to take effect. Installing Or Upgrading the EqualLogic MEM On Your VMware ESXi Host The EqualLogic MEM is packaged as a VMware Infrastructure Bundle (VIB). There are two methods for installing this VIB, as described in Table 5. Table 5: Installation Methods Method Description Refer To VMware Update Manager (vum) ESX CLI install command from vsphere Load the VIB using the Import Patch option. Use the esxcli software vib install command. Installing the MEM Using vcenter Update Manager on page 10 Installing the MEM Plugin Using the ESX CLI on page 10 Note: You are required to put the VMware ESXi host in maintenance mode when installing the EqualLogic MEM, unless performing an operation that requires a reboot, such as an upgrade install. vcenter Update Manager automatically puts the ESXi host in maintenance mode as part of the installation process. For network configuration, see Configuring Your Network for the MEM Plugin on page 7. To modify the EHCM configuration, see Chapter 3, Configuring the EqualLogic MEM. For instructions on uninstallation, see Removing the EqualLogic Plugin on page 11. Tasks Performed During the Installation Process The installation of the EqualLogic MEM performs the following tasks: Registers the PSP. Configures EHCM to automatically start when VMware ESX is booted. Sets the EqualLogic PSP as the active PSP for all VMware EQLOGIC iscsi disk devices. 9
14 EqualLogic MEM Installation and User Guide 2 Installing the EqualLogic MEM Sets the EqualLogic PSP as the default for any new VMware EQLOGIC iscsi disk devices. Installing the MEM Using vcenter Update Manager Use the following steps to install the MEM using the vsphere Update Manager (vum): 1. Install and configure vum, according to VMware instructions. 2. Import the MEM offline bundle into the vum package repository by selecting the Import Patches option and browsing to the dell-eql-mem-<version>.zip. 3. Create a baseline containing the MEM bundle. Be sure to choose a Host Extension type for the baseline. 4. Optionally add the new baseline to a baseline group. 5. Attach the baseline or baseline group to one or more hosts. 6. Scan and remediate to install the MEM on the desired hosts. Update Manager will put the hosts in maintenance mode and reboot if necessary as part of the installation process. For complete instructions on using vsphere Update Manager, see the Installing and Administering VMware vsphere Update Manager documentation available from VMware. Note: When importing the patch, be sure to import it as a third-party host extension. Installing the MEM Plugin Using the ESX CLI Use the following ESX CLI command syntax to install the EqualLogic MEM plugin: esxcli --server="hostname" software vib install -d bundle The -d parameter specifies the path to the offline bundle file containing multipathing plugin (dell-eql-mem-<version>.zip). Note: To install the offline bundle, you must first copy it to a location that is accessible from the ESXi host. The install command can then be run from any esxcli client, giving the full path to the bundle on the host. For example, if you upload the bundle to a datastore named datastore1, it can then be installed with the following command: C:\>esxcli --server XXX.XXX software vib install --depot /vmfs/ volumes/datastore1/dell-eql-mem zip Enter username: root Enter password: Installation Result Message: Operation finished successfully. Reboot Required: false 10
15 EqualLogic MEM Installation and User Guide 2 Installing the EqualLogic MEM VIBs Installed: Dell_bootbank_dell-eql-host-connection-mgr_ ,Dell_ bootbank_dell-eql-hostprofile_ , Dell_bootbank_dell-eql-routed-psp_ VIBs Removed: VIBs Skipped: Notes: This bundle should not be unzipped, as the installation tools expect it in.zip format. Make sure that the path to the bundle you specify is relative to the the ESXi host. Removing the EqualLogic Plugin Use the following ESX CLI command syntax to remove the EqualLogic plugin vibs: esxcli --server="hostname" software vib remove -n [bundle] For example: # esxcli software vib list grep dell Name Version Vendor Acceptance Level Install Date dell-eql-host-connection-mgr Dell VMwareCertified dell-eql-hostprofile Dell VMwareCertified dell-eql-routed-psp Dell VMwareCertified To remove the MEM, you must specify all the vibs on the command line: # esxcli software vib remove -n dell-eql-host-connection-mgr -n dell-eql-hostprofile -n dell-eql-routed-psp Enter username: root Enter password: Removal Result Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective. Reboot Required: true VIBs Installed: VIBs Removed: Dell_bootbank_dell-eql-host-connection-mgr_ , Dell_bootbank_delleql-hostprofile_ , Dell_bootbank_dell-eql-routed-psp_ VIBs Skipped: Verifying the Installation To verify that the installation was successful, use the setup.pl --query command. 11
16 EqualLogic MEM Installation and User Guide 2 Installing the EqualLogic MEM For example: $./setup.pl --server= xx.xxx --query Found Dell EqualLogic multipathing package installed: DELL-eql-mem Default PSP for EqualLogic devices is DELL_PSP_EQL_ROUTED No supported iscsi adapters found. Enabling and Disabling the EqualLogic Plugin Use the setup.pl script to enable and disable the EqualLogic MEM plug-in. Enabling the EqualLogic Plugin Enabling the plugin sets the PSP as the active PSP for all existing EqualLogic disk devices, and sets it as the default PSP for all new EqualLogic disk devices. Use the following syntax to enable the EqualLogic MEM plugin: setup.pl --disable --server="hostname" [--username=username] [--password=password] The plugin is automatically enabled when it is installed. Disabling the EqualLogic Plugin Disabling the plugin sets VMW_PSP_FIXED as the active PSP for all existing EqualLogic disk devices, and sets it as the default PSP for all new EqualLogic disk devices. Use the following syntax to disable the EqualLogic MEM plugin: setup.pl --enable --server="hostname" [--username=username] [--password=password] Using the EqualLogic MEM With AutoDeploy The Dell EqualLogic MEM supports the new AutoDeploy feature in ESX 5 that allows building images for automatically deploying ESX hosts. In order to add the MEM to the boot image you must perform the following additional steps while preparing the image profile using the PowerCLI: 1. Import the MEM offline bundle using the Add-EsxSoftwareDepot command. For example, Add-EsxSoftwareDepot <depot>.zip 2. Add the three VIBs in the MEM to the image profile. For example: Add-EsxSoftwarePackage -imageprofile <name> -SoftwarePackage dell-eql-routed-psp Add-EsxSoftwarePackage -imageprofile <name> -SoftwarePackage dell-eql-host-connection-mgr Add-EsxSoftwarePackage -imageprofile <name> -SoftwarePackage dell-eql-hostprofile 12
17 EqualLogic MEM Installation and User Guide 2 Installing the EqualLogic MEM See the vsphere Installation and Setup documentation available from VMware for more information about AutoDeploy. 13
18
19 3 Configuring the EqualLogic MEM EHCM Configuration The runtime behavior of EHCM is controlled by several configuration values. Table 6 describes these configuration values. Table 6: EHCM Configuration Parameters Value Default Maximim Minimum Description TotalSessions VolumeSessions MemberSessions MinAdapterSpeed Maximum total sessions created to all EqualLogic volumes. You can lower this limit in large configurations to keep the session count within VMware ESX and PS group limits. Maximum number of sessions created to each EqualLogic volume. You can lower this limit in large configurations to keep the session count within VMware ESX and PS group limits. Maximum number of sessions created to each volume slice (portion of a volume on a single member). Minimum adapter speed (in Mb/s) used for MPIO sessions. When determining how many sessions to create to a volume, EHCM chooses a value that meets all constraints specified by the totalsessions, volumesessions and membersessions values. See the PS Series documentation for group limits on total iscsi sessions. It may be necessary to reduce the number of sessions created per volume in large configurations. EHCM Configuration File The configuration file, located on the ESX host at /etc/cim/dell/ehcmd.conf, stores the configuration parameters. The preferred method of making changes is through the esxcli command esxcli equallogic param set, but this file can also be edited directly. Each line in the file uses the format param=<value>. Table 6 shows available options and their values. EqualLogic MEM Configuration Using ESX CLI Commands You can use the ESX CLI to configure and inspect the EqualLogic MEM. 15
20 EqualLogic MEM Installation and User Guide 3 Configuring the EqualLogic MEM For a full description of the ESX CLI commands, see the VMware documentation. Viewing Configuration Values To view the current configuration parameters, use the following ESX CLI command syntax: esxcli equallogic param list For example: $esxcli equallogic param list Listing Statistics To view statistics, use the following ESX CLI command syntax: esxcli equallogic stat {detail summary} [--device=<device>] [--path] The following options can be used: The device parameter allows filtering to display just stats for one device. The path parameter will cause stats to be reported for each path. The detail parameter will cause detailed statistics to be reported instead of summary statistics. For example: $ esxcli equallogic stat summary Listing Adapters To view adapters, use the following ESX CLI command syntax: esxcli equallogic adapters For example: 16
21 EqualLogic MEM Installation and User Guide 3 Configuring the EqualLogic MEM $ esxcli equallogic adapters VMKernel: vmk1 Ip: xxx.xx Status: Normal NIC: vmnic1 Speed: 1000 MAC: 00:1e:c9:b5:04:75 HBA: vmhba33 Vendor: VMware:iSCSI Software Adapter VMKernel: vmk2 Ip: xxx.xx Status: Normal NIC: vmnic2 Speed: 1000 MAC: 00:1b:21:23:61:00 HBA: vmhba33 Vendor: VMware:iSCSI Software Adapter Listing Sessions To list sessions, use the following ESX CLI command syntax: esxcli equallogic sessions For example: $esxcli equallogic sessions VolumeName SrcIp TgtIp esx5datastore XXX XX.212 esx5datastore XXX XX.221 esx5datastore XXX XX.211 esx5datastore XXX XX.222 esx5vm XXX XX.222 esx5vm XXX XX.221 esx5vm XXX XX.212 esx5vm XXX XX.211 esx5vm XXX XX.221 esx5vm XXX XX.211 esx5vm XXX XX.222 esx5vm XXX XX.212 esx5vm XXX XX.212 esx5vm XXX XX.211 esx5vm XXX XX.222 esx5vm XXX XX.222 esx5vm XXX XX.221 esx5vm XXX XX.222 esx5vm XXX XX.212 esx5vm XXX XX.221 esx5vm XXX XX.211 esx5vm XXX XX.221 esx5vm XXX XX.212 esx5vm XXX XX
22 EqualLogic MEM Installation and User Guide 3 Configuring the EqualLogic MEM Setting Configuration Values To configure the EqualLogic MEM, use the following ESX CLI command syntax: esxcli equallogic param set --name="parameter_name" --value="parameter_value" For example: $ esxcli equallogic param set -n=volumesessions -v=3 EqualLogic MEM Configuration Using Host Profiles In vsphere 5.0, Host Profiles are extended to support third party providers. The EqualLogic MEM contains such a host profile provider, that allows management of some MEM configuration parameters through the Host Profile framework. Support Host Profile operations include: Extract current MEM configuration from a host Edit the configuration settings in an existing host profile Check compliance of a host against a host profile Apply a host profile to one or more hosts See the vsphere Host Profiles documentation available from VMware for more information about using Host Profiles. 18
23 4 Troubleshooting This chapter discusses topics relating to troubleshooting the Dell EqualLogic MEM. Log Files Table 7 shows the log file used by the EqualLogic MEM. Log File Name /var/log/equallogic/ehcmd.log /var/log/vmkernel.log Error messages are also sent to syslog. Table 7: Log Files Description Contains EHCMD log messages for ESX and ESXi Includes PSP log messages (ESX) To produce a dump of the details of the current MPIO configuration to a file, use the following command from the ESX CLI service console: /usr/sbin/ehcmcli -d -o <filename> Troubleshooting Common Issues Table 8 identifies common issues for the Dell EqualLogic MEM. 19
24 EqualLogic MEM Installation and User Guide 4 Troubleshooting Problem Cannot install the MEM bundle Table 8: Troubleshooting the Dell EqualLogic MEM iscsi logins cannot be seen from any vmknics iscsi logins cannot be seen from all vmknics Array limits of iscsi sessions exceeded Logins from Broadcom NIC with iscsi offload cannot be seen Do not see the expected number of sessions for Broadcom NIC with iscsi offload esxcli equallogic commands are not recognized Possible Cause/Solution The VIB was unzipped before installation The VIB was not first copied to the ESXi location Do not bind vmknics to the iscsi initiator. See Software iscsi Configuration Requirements on page 5. Volume access is not properly set for all vmknics to login. Note: Broadcom iscsi offload uses a different IQN for each port. Session limits on ESX server need to be lowered, using esxcli equallogic param set n totalsessions. See Setting Configuration Values on page 18. The Broadcom iscsi offload does not support jumbo frames. vmknic and vswitch MTU must be set to The Broadcom iscsi offload has a low limit on iscsi sessions (64 or 128). In addition, the EHCM will leave two empty slots so additional iscsi targets can be discovered. The hostd daemon was not restarted after the plugin installation. 20
25 A Sample Configuration Commands This appendix provides examples of using the setup.pl script to configure networking for multipathing. Configuring a 4-Port Nic Using the VMware Software iscsi Initiator $./setup.pl --server= xxx configure --ips= xxx.131, xxx.132, xxx.133, xxx nics=vmnic2,vmnic3,vmnic4,vmnic5 --enableswiscsi --nohwiscsi Configuring networking for iscsi multipathing: vswitch = vswitchiscsi mtu = 1500 nics = vmnic2 vmnic3 vmnic4 vmnic5 ips = XXX XXX XXX XXX.134 netmask = vmkernel = iscsi enableswiscsi = 1 Creating vswitch vswitchiscsi. Setting vswitch MTU to Creating portgroup iscsi0 on vswitch vswitchiscsi. Assigning IP address XXX.131 to iscsi0. Creating portgroup iscsi1 on vswitch vswitchiscsi. Assigning IP address XXX.132 to iscsi1. Creating portgroup iscsi2 on vswitch vswitchiscsi. Assigning IP address XXX.133 to iscsi2. Creating portgroup iscsi3 on vswitch vswitchiscsi. Assigning IP address XXX.134 to iscsi3. Creating new bridge. Adding uplink vmnic2 to vswitchiscsi. Adding uplink vmnic3 to vswitchiscsi. Adding uplink vmnic4 to vswitchiscsi. Adding uplink vmnic5 to vswitchiscsi. Setting new uplinks for vswitchiscsi. Setting uplink for iscsi0 to vmnic2. 21
26 EqualLogic MEM Installation and User Guide A Sample Configuration Commands Setting uplink for iscsi1 to vmnic3. Setting uplink for iscsi2 to vmnic4. Setting uplink for iscsi3 to vmnic5. Enabling SW initiator. Enabled SW initiator. Bound vmk0 to vmhba35. Bound vmk1 to vmhba35. Bound vmk3 to vmhba35. Bound vmk4 to vmhba35. Configuration finished. Resulting configuration: $ esxcfg-vswitch -l --server XXX username root --password <secret> Switch Name Num Ports Used Ports Configured Ports MTU Uplinks vswitch vmnic0 PortGroup Name VLAN ID Used Ports Uplinks VM Network 0 0 vmnic0 Service Console 0 1 vmnic0 Switch Name Num Ports Used Ports Configured Ports MTU Uplinks vswitchiscsi vmnic2,vmnic3, vmnic4, vmnic5 PortGroup Name VLAN ID Used Ports Uplinks iscsi3 0 1 vmnic5 iscsi2 0 1 vmnic4 iscsi1 0 1 vmnic3 iscsi0 0 1 vmnic2 Configuring a Two-Port Broadcom Enabled For iscsi Offload $./setup.pl --server= xxx configureips= xxx.161, xxx nics=vmnic4,vmnic5 Configuring networking for iscsi multipathing: vswitch = vswitchiscsi mtu = 1500 nics = vmnic4 vmnic5 22
27 EqualLogic MEM Installation and User Guide A Sample Configuration Commands ips = XXX XXX.162 netmask = vmkernel = iscsi Creating vswitch vswitchiscsi. Setting vswitch MTU to Creating portgroup iscsi0 on vswitch vswitchiscsi. Assigning IP address XXX.161 to iscsi0. Creating portgroup iscsi1 on vswitch vswitchiscsi. Assigning IP address XXX.162 to iscsi1. Creating new bridge. Adding uplink vmnic4 to vswitchiscsi. Adding uplink vmnic5 to vswitchiscsi. Setting new uplinks for vswitchiscsi. Setting uplink for iscsi0 to vmnic4. Setting uplink for iscsi1 to vmnic5. Bound vmk0 to vmhba34. Bound vmk1 to vmhba35. Configuration finished. Resulting configuration: $ esxcfg-vswitch -l --server XXX username root --password <secret> Switch Name Num Ports Used Ports Configured Ports MTU Uplinks vswitch vmnic0 PortGroup Name VLAN ID Used Ports Uplinks VM Network 0 0 vmnic0 Service Console 0 1 vmnic0 Switch Name Num Ports Used Ports Configured Ports MTU Uplinks vswitchiscsi vmnic4,vmnic5 PortGroup Name VLAN ID Used Ports Uplinks iscsi1 0 1 vmnic5 iscsi0 0 1 vmnic4 23
28
29 B Technical Support and Customer Service Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services might not be available in your area. For customers in the United States, call Note: If you do not have access to an Internet connection, contact information is printed on your invoice, packing slip, bill, or Dell product catalog. Use the following procedure to contact Dell for sales, technical support, or customer service issues: 1. Visit support.dell.com or the Dell support URL specified in information provided with the Dell product. 2. Select your locale. Use the locale menu or click on the link that specifies your country or region. 3. Select the required service. Click the Contact Us link, or select the Dell support service from the list of services provided. 4. Choose your preferred method of contacting Dell support, such as or telephone. Online Services You can learn about Dell products and services using the following procedure: 1. Visit (or the URL specified in any Dell product information). 2. Use the locale menu or click on the link that specifies your country or region. 25
30
31 Index A adapters listing 16 AutoDeploy 12 C configuration file 15 configuration parameters viewing 16 configuration values setting 18 configuring the EqualLogic MEM 15 E EHCM 1, 15 ehcmd 15 EqualLogic Host Connection Manager 1 ESX CLI commands 16 H host profiles 18 I installation N NIC teaming 6 P Pluggable Storage Architecture 1 PSP 1 S sessions listing 17 stateless boot 12 statistics listing 16 V vcenter Update Manager 10 VIB 5 VMkernel 6 VMkernel port 6 binding 6 VMware ESX configuration 5 VMware iscsi Initiator 6 vswitch 6 vum 10 EqualLogic MEM 9 tasks performed 9 iscsi sessions 15 J jumbo frames 6 M Multipathing Extension Module 1 27
32
Multipathing Configuration for Software iscsi Using Port Binding
Multipathing Configuration for Software iscsi Using Port Binding Technical WHITE PAPER Table of Contents Multipathing for Software iscsi.... 3 Configuring vmknic-based iscsi Multipathing.... 3 a) Configuring
Configuring iscsi Multipath
CHAPTER 13 Revised: April 27, 2011, OL-20458-01 This chapter describes how to configure iscsi multipath for multiple routes between a server and its storage devices. This chapter includes the following
VMware vsphere-6.0 Administration Training
VMware vsphere-6.0 Administration Training Course Course Duration : 20 Days Class Duration : 3 hours per day (Including LAB Practical) Classroom Fee = 20,000 INR Online / Fast-Track Fee = 25,000 INR Fast
Deploying and updating VMware vsphere 5.0 on HP ProLiant Servers
Deploying and updating VMware vsphere 5.0 on HP ProLiant Servers Integration Note Introduction... 2 Deployment... 2 ESXi 5.0 deployment location options... 2 ESXi 5.0 image options... 2 VMware ESXi Image
Cisco Nexus 1000V Virtual Ethernet Module Software Installation Guide, Release 4.0(4)SV1(1)
Cisco Nexus 1000V Virtual Ethernet Module Software Installation Guide, Release 4.0(4)SV1(1) September 17, 2010 Part Number: This document describes how to install software for the Cisco Nexus 1000V Virtual
Best Practices when implementing VMware vsphere in a Dell EqualLogic PS Series SAN Environment
Technical Report Best Practices when implementing VMware vsphere in a Dell EqualLogic PS Series SAN Environment Abstract This Technical Report covers Dell recommended best practices when configuring a
Configuring VMware vsphere Software iscsi With Dell EqualLogic PS Series Storage
TECHNICAL REPORT Configuring VMware vsphere Software iscsi With Dell EqualLogic PS Series Storage ABSTRACT This Technical Report will explain how to configure and connect a Dell EqualLogic PS Series SAN
vsphere Networking vsphere 5.5 ESXi 5.5 vcenter Server 5.5 EN-001074-02
vsphere 5.5 ESXi 5.5 vcenter Server 5.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more
Installing and Administering VMware vsphere Update Manager
Installing and Administering VMware vsphere Update Manager Update 1 vsphere Update Manager 5.1 This document supports the version of each product listed and supports all subsequent versions until the document
VMware for Bosch VMS. en Software Manual
VMware for Bosch VMS en Software Manual VMware for Bosch VMS Table of Contents en 3 Table of contents 1 Introduction 4 1.1 Restrictions 4 2 Overview 5 3 Installing and configuring ESXi server 6 3.1 Installing
Storage Protocol Comparison White Paper TECHNICAL MARKETING DOCUMENTATION
Storage Protocol Comparison White Paper TECHNICAL MARKETING DOCUMENTATION v 1.0/Updated APRIl 2012 Table of Contents Introduction.... 3 Storage Protocol Comparison Table....4 Conclusion...10 About the
Bosch Video Management System High availability with VMware
Bosch Video Management System High availability with VMware en Technical Note Bosch Video Management System Table of contents en 3 Table of contents 1 Introduction 4 1.1 Restrictions 4 2 Overview 5 3
ESX Configuration Guide
ESX 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions
Dell PowerVault MD32xx Deployment Guide for VMware ESX4.1 Server
Dell PowerVault MD32xx Deployment Guide for VMware ESX4.1 Server A Dell Technical White Paper PowerVault MD32xx Storage Array www.dell.com/md32xx THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND
vsphere Networking vsphere 6.0 ESXi 6.0 vcenter Server 6.0 EN-001391-01
vsphere 6.0 ESXi 6.0 vcenter Server 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more
What s New in VMware vsphere 5.0 Platform
What s New in VMware vsphere 5.0 Platform VMware vsphere 5.0 Technical WHITE PAPER v 1/Updated May 2011 Table Of Contents Introduction... 3 Virtual Machine Enhancements... 3 Virtual Machine Scalability
VMware vsphere 4.1 with ESXi and vcenter
VMware vsphere 4.1 with ESXi and vcenter This powerful 5-day class is an intense introduction to virtualization using VMware s vsphere 4.1 including VMware ESX 4.1 and vcenter. Assuming no prior virtualization
Drobo How-To Guide. Deploy Drobo iscsi Storage with VMware vsphere Virtualization
The Drobo family of iscsi storage arrays allows organizations to effectively leverage the capabilities of a VMware infrastructure, including vmotion, Storage vmotion, Distributed Resource Scheduling (DRS),
Setup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service ESX 4.0 ESXi 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the
VMware vsphere: Fast Track [V5.0]
VMware vsphere: Fast Track [V5.0] Experience the ultimate in vsphere 5 skills-building and VCP exam-preparation training. In this intensive, extended-hours course, you will focus on installing, configuring,
Migrating to ESXi: How To
ILTA Webinar Session Migrating to ESXi: How To Strategies, Procedures & Precautions Server Operations and Security Technology Speaker: Christopher Janoch December 29, 2010 Migrating to ESXi: How To Strategies,
VMware vsphere 5.0 Boot Camp
VMware vsphere 5.0 Boot Camp This powerful 5-day 10hr/day class is an intensive introduction to VMware vsphere 5.0 including VMware ESX 5.0 and vcenter. Assuming no prior virtualization experience, this
Deploying Dell OpenManage Server Administrator on VMware ESXi Using Dell Online Depot and VMware Update Manager
Deploying Dell OpenManage Server Administrator on VMware ESXi Using Dell Online Depot and VMware Update Manager July 2013 Deepti Madhu Krishnaprasad K Deploying Dell OpenManage Server Administrator on
VMware vsphere Reference Architecture for Small Medium Business
VMware vsphere Reference Architecture for Small Medium Business Dell Virtualization Business Ready Configuration b Dell Virtualization Solutions Engineering www.dell.com/virtualization/businessready Feedback:
VMware vsphere 5.1 Advanced Administration
Course ID VMW200 VMware vsphere 5.1 Advanced Administration Course Description This powerful 5-day 10hr/day class is an intensive introduction to VMware vsphere 5.0 including VMware ESX 5.0 and vcenter.
VM-Series Firewall Deployment Tech Note PAN-OS 5.0
VM-Series Firewall Deployment Tech Note PAN-OS 5.0 Revision A 2012, Palo Alto Networks, Inc. www.paloaltonetworks.com Contents Overview... 3 Supported Topologies... 3 Prerequisites... 4 Licensing... 5
Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN
Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN A Dell EqualLogic best practices technical white paper Storage Infrastructure and Solutions Engineering Dell Product Group November 2012 2012
Set Up a VM-Series Firewall on an ESXi Server
Set Up a VM-Series Firewall on an ESXi Server Palo Alto Networks VM-Series Deployment Guide PAN-OS 6.0 Contact Information Corporate Headquarters: Palo Alto Networks 4401 Great America Parkway Santa Clara,
ESXi Configuration Guide
ESXi 4.1 vcenter Server 4.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions
Dell EqualLogic Best Practices Series
Dell EqualLogic Best Practices Series Scaling and Best Practices for Implementing VMware vsphere Based Virtual Workload Environments with the Dell EqualLogic FS7500 A Dell Technical Whitepaper Storage
VMware vsphere 5.0 Evaluation Guide
VMware vsphere 5.0 Evaluation Guide Auto Deploy TECHNICAL WHITE PAPER Table of Contents About This Guide.... 4 System Requirements... 4 Hardware Requirements.... 4 Servers.... 4 Storage.... 4 Networking....
vsphere Upgrade vsphere 6.0 EN-001721-03
vsphere 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions of this document,
E-SPIN's Virtualization Management, System Administration Technical Training with VMware vsphere Enterprise (7 Day)
Class Schedule E-SPIN's Virtualization Management, System Administration Technical Training with VMware vsphere Enterprise (7 Day) Date: Specific Pre-Agreed Upon Date Time: 9.00am - 5.00pm Venue: Pre-Agreed
How to Create a Virtual Switch in VMware ESXi
How to Create a Virtual Switch in VMware ESXi I am not responsible for your actions or their outcomes, in any way, while reading and/or implementing this tutorial. I will not provide support for the information
Set Up a VM-Series Firewall on an ESXi Server
Set Up a VM-Series Firewall on an ESXi Server Palo Alto Networks VM-Series Deployment Guide PAN-OS 6.1 Contact Information Corporate Headquarters: Palo Alto Networks 4401 Great America Parkway Santa Clara,
vsphere Networking ESXi 5.0 vcenter Server 5.0 EN-000599-01
ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions
vsphere Host Profiles
ESXi 5.1 vcenter Server 5.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions
ESX 4 Patch Management Guide ESX 4.0
ESX 4 Patch Management Guide ESX 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent
How to Configure an Initial Installation of the VMware ESXi Hypervisor
How to Configure an Initial Installation of the VMware ESXi Hypervisor I am not responsible for your actions or their outcomes, in any way, while reading and/or implementing this tutorial. I will not provide
Setup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service Update 1 ESX 4.0 ESXi 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until
DELL 3-2-1 REFERENCE CONFIGURATIONS: HIGH-AVAILABILITY VIRTUALIZATION WITH DELL POWEREDGE R720 SERVERS
DELL 3-2-1 REFERENCE CONFIGURATIONS: HIGH-AVAILABILITY VIRTUALIZATION WITH DELL POWEREDGE R720 SERVERS A Principled Technologies configuration guide commissioned by Dell Inc. TABLE OF CONTENTS Table of
Khóa học dành cho các kỹ sư hệ thống, quản trị hệ thống, kỹ sư vận hành cho các hệ thống ảo hóa ESXi, ESX và vcenter Server
1. Mục tiêu khóa học. Khóa học sẽ tập trung vào việc cài đặt, cấu hình và quản trị VMware vsphere 5.1. Khóa học xây dựng trên nền VMware ESXi 5.1 và VMware vcenter Server 5.1. 2. Đối tượng. Khóa học dành
s@lm@n VMware Exam 2V0-621D VMware Certified Professional 6 Data Center Virtualization Delta Beta Exam Version: 6.0 [ Total Questions: 221 ]
s@lm@n VMware Exam 2V0-621D VMware Certified Professional 6 Data Center Virtualization Delta Beta Exam Version: 6.0 [ Total Questions: 221 ] Question No : 1 Which three traffic types can be configured
Exinda How to Guide: Virtual Appliance. Exinda ExOS Version 6.3 2012 Exinda, Inc
Exinda How to Guide: Virtual Appliance Exinda ExOS Version 6.3 2 Virtual Appliance Table of Contents Part I Introduction 4 1 Using... this Guide 4 Part II Overview 6 Part III Deployment Options 8 Part
ISRX207VE11-1. NEC Storage PathManager for VMware Installation Guide
NEC Storage PathManager for VMware Installation Guide Preface This document describes about the installation of the program products in the CD labeled as: NEC Storage PathManager for VMware English Version
Host Integration Tools
Host Integration Tools Installation and User Guide Version 3.4 Copyright 2010 Dell, Inc. All rights reserved. EqualLogic is a registered trademark of Dell, Inc. Dell is a trademark of Dell, Inc. All trademarks
Using Dell EqualLogic and Multipath I/O with Citrix XenServer 6.2
Using Dell EqualLogic and Multipath I/O with Citrix XenServer 6.2 Dell Engineering Donald Williams November 2013 A Dell Deployment and Configuration Guide Revisions Date November 2013 Description Initial
Dell High Availability Solutions Guide for Microsoft Hyper-V
Dell High Availability Solutions Guide for Microsoft Hyper-V www.dell.com support.dell.com Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer.
VMWARE VSPHERE 5.0 WITH ESXI AND VCENTER
VMWARE VSPHERE 5.0 WITH ESXI AND VCENTER CORPORATE COLLEGE SEMINAR SERIES Date: April 15-19 Presented by: Lone Star Corporate College Format: Location: Classroom instruction 8 a.m.-5 p.m. (five-day session)
ClearPass Policy Manager 6.3
ClearPass Policy Manager 6.3 Tech Note: Installing or Upgrading on a Virtual Machine This document describes the procedures for installing and upgrading ClearPass Policy Manager 6.3 on a Virtual Machine.
MIGRATING LEGACY PHYSICAL SERVERS TO VMWARE VSPHERE VIRTUAL MACHINES ON DELL POWEREDGE M610 BLADE SERVERS FEATURING THE INTEL XEON PROCESSOR 5500
MIGRATING LEGACY PHYSICAL SERVERS TO VMWARE VSPHERE VIRTUAL MACHINES ON DELL POWEREDGE M610 BLADE SERVERS FEATURING THE INTEL XEON PROCESSOR 5500 SERIES Table of contents... 1 Table of contents... 2 Introduction...
vsphere Auto Deploy Update 1 ESXi 5.0 vcenter Server 5.0 EN-000847-01
Update 1 ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent
SAN Implementation Course SANIW; 3 Days, Instructor-led
SAN Implementation Course SANIW; 3 Days, Instructor-led Course Description In this workshop course, you learn how to connect Windows, vsphere, and Linux hosts via Fibre Channel (FC) and iscsi protocols
ESX Server 3 Configuration Guide Update 2 and later for ESX Server 3.5 and VirtualCenter 2.5
ESX Server 3 Configuration Guide Update 2 and later for ESX Server 3.5 and VirtualCenter 2.5 This document supports the version of each product listed and supports all subsequent versions until the document
vrealize Operations Manager Customization and Administration Guide
vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.0.1 This document supports the version of each product listed and supports all subsequent versions until
SonicWALL SRA Virtual Appliance Getting Started Guide
COMPREHENSIVE INTERNET SECURITY SonicWALL Secure Remote Access Appliances SonicWALL SRA Virtual Appliance Getting Started Guide SonicWALL SRA Virtual Appliance5.0 Getting Started Guide This Getting Started
VMware vcenter Update Manager Administration Guide
VMware vcenter Update Manager Administration Guide vcenter Update Manager 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced
Altor Virtual Network Security Analyzer v1.0 Installation Guide
Altor Virtual Network Security Analyzer v1.0 Installation Guide The Altor Virtual Network Security Analyzer (VNSA) application is deployed as Virtual Appliance running on VMware ESX servers. A single Altor
EMC Data Domain Management Center
EMC Data Domain Management Center Version 1.1 Initial Configuration Guide 302-000-071 REV 04 Copyright 2012-2015 EMC Corporation. All rights reserved. Published in USA. Published June, 2015 EMC believes
Virtual Appliance Setup Guide
The Virtual Appliance includes the same powerful technology and simple Web based user interface found on the Barracuda Web Application Firewall hardware appliance. It is designed for easy deployment on
Setup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service Update 1 ESXi 5.1 vcenter Server 5.1 This document supports the version of each product listed and supports all subsequent versions until the
vsphere Private Cloud RAZR s Edge Virtualization and Private Cloud Administration
Course Details Level: 1 Course: V6PCRE Duration: 5 Days Language: English Delivery Methods Instructor Led Training Instructor Led Online Training Participants: Virtualization and Cloud Administrators,
Setup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service ESX 4.1 ESXi 4.1 vcenter Server 4.1 This document supports the version of each product listed and supports all subsequent versions until the
Study Guide. Professional vsphere 4. VCP VMware Certified. (ExamVCP4IO) Robert Schmidt. IVIC GratAf Hill
VCP VMware Certified Professional vsphere 4 Study Guide (ExamVCP4IO) Robert Schmidt McGraw-Hill is an independent entity from VMware Inc. and is not affiliated with VMware Inc. in any manner.this study/training
Cedric Rajendran VMware, Inc. Security Hardening vsphere 5.5
Cedric Rajendran VMware, Inc. Security Hardening vsphere 5.5 Agenda Security Hardening vsphere 5.5 ESXi Architectural Review ESXi Software Packaging The ESXi Firewall ESXi Local User Security Host Logs
VMware vsphere Examples and Scenarios
VMware vsphere Examples and Scenarios ESXi 5.1 vcenter Server 5.1 vsphere 5.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced
Network Troubleshooting & Configuration in vsphere 5.0. 2010 VMware Inc. All rights reserved
Network Troubleshooting & Configuration in vsphere 5.0 2010 VMware Inc. All rights reserved Agenda Physical Network Introduction to Virtual Network Teaming - Redundancy and Load Balancing VLAN Implementation
Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide
Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
Drobo How-To Guide. Use a Drobo iscsi Array as a Target for Veeam Backups
This document shows you how to use a Drobo iscsi SAN Storage array with Veeam Backup & Replication version 5 in a VMware environment. Veeam provides fast disk-based backup and recovery of virtual machines
Business-Ready Configurations for VMware vsphere 4 with PowerEdge R810 Servers and EqualLogic PS6010 Storage Arrays Utilizing iscsi Boot Technology
Business-Ready Configurations for VMware vsphere 4 with PowerEdge R810 Servers and EqualLogic PS6010 Storage Arrays Utilizing iscsi Boot Technology A Solution Guide Vishvesh Sahasrabudhe Dell Virtualization
Enterprise. ESXi in the. VMware ESX and. Planning Deployment of. Virtualization Servers. Edward L. Haletky
VMware ESX and ESXi in the Enterprise Planning Deployment of Virtualization Servers Edward L. Haletky PRENTICE HALL Upper Saddle River, NJ Boston Indianapolis San Francisco New York Toronto Montreal London
Sizing and Best Practices for Deploying Microsoft Exchange Server 2010 on VMware vsphere and Dell EqualLogic Storage
Dell EqualLogic Best Practices Series Sizing and Best Practices for Deploying Microsoft Exchange Server 2010 on VMware vsphere and Dell EqualLogic Storage A Dell Technical Whitepaper Ananda Sankaran Storage
Vmware VSphere 6.0 Private Cloud Administration
To register or for more information call our office (208) 898-9036 or email [email protected] Vmware VSphere 6.0 Private Cloud Administration Class Duration 5 Days Introduction This fast paced,
Setup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the document
How to Setup and Configure ESXi 5.0 and ESXi 5.1 for OpenManage Essentials
How to Setup and Configure ESXi 5.0 and ESXi 5.1 for OpenManage Essentials This Dell technical white paper provides step-by-step instructions to set up and configure ESXi for OpenManage Essentials. BBenjamin
iscsi SAN Configuration Guide
ESX 4.1 ESXi 4.1 vcenter Server 4.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent
VMware vcenter Support Assistant 5.1.1
VMware vcenter.ga September 25, 2013 GA Last updated: September 24, 2013 Check for additions and updates to these release notes. RELEASE NOTES What s in the Release Notes The release notes cover the following
Remote PC Guide Series - Volume 1
Introduction and Planning for Remote PC Implementation with NETLAB+ Document Version: 2016-02-01 What is a remote PC and how does it work with NETLAB+? This educational guide will introduce the concepts
BLACK BOX. Quick Start Guide. Virtual Central Management System (VCMS) Works with LES Series Console Servers. LES-VCMS. Customer Support Information
LES-VCMS Virtual Central Management System (VCMS) Quick Start Guide Works with LES Series Console Servers. BLACK BOX Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside
Deploying Microsoft Hyper-V with Dell EqualLogic PS Series Arrays
TECHNICAL REPORT Deploying Microsoft Hyper-V with Dell EqualLogic PS Series Arrays ABSTRACT This technical report details information and best practices for deploying Microsoft Hyper-V with Dell EqualLogic
Configuring VMware vsphere 5.1 with Oracle ZFS Storage Appliance and Oracle Fabric Interconnect
An Oracle Technical White Paper October 2013 Configuring VMware vsphere 5.1 with Oracle ZFS Storage Appliance and Oracle Fabric Interconnect An IP over InfiniBand configuration overview for VMware vsphere
Patch Management. Module 13. 2012 VMware Inc. All rights reserved
Patch Management Module 13 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks Configuring and Managing
Windows Host Utilities 6.0.2 Installation and Setup Guide
Windows Host Utilities 6.0.2 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
ASM Educational Center (ASM) Est. 1992. VMS-ICM v5.5 - VMware vsphere: Install, Configure, Manage Training Program
VMS-ICM v5.5 - VMware vsphere: Install, Configure, Manage Training Program Course Outline Chapter 01 - Course Introduction and Methodology Learn IT! Do IT! Know IT! Certified Virtualization Expert (CVE)
Dell Networking Solutions Guide for Microsoft Hyper-V
Dell Networking Solutions Guide for Microsoft Hyper-V www.dell.com support.dell.com Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
Install Guide for JunosV Wireless LAN Controller
The next-generation Juniper Networks JunosV Wireless LAN Controller is a virtual controller using a cloud-based architecture with physical access points. The current functionality of a physical controller
vshield Quick Start Guide
vshield Manager 5.0 vshield App 5.0 vshield Edge 5.0 vshield Endpoint 5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by
Building a Penetration Testing Virtual Computer Laboratory
Building a Penetration Testing Virtual Computer Laboratory User Guide 1 A. Table of Contents Collaborative Virtual Computer Laboratory A. Table of Contents... 2 B. Introduction... 3 C. Configure Host Network
Installing and Using the vnios Trial
Installing and Using the vnios Trial The vnios Trial is a software package designed for efficient evaluation of the Infoblox vnios appliance platform. Providing the complete suite of DNS, DHCP and IPAM
Aerohive Networks Inc. Free Bonjour Gateway FAQ
Aerohive Networks Inc. Free Bonjour Gateway FAQ 1. About the Product... 1 2. Installation... 2 3. Management... 3 4. Troubleshooting... 4 1. About the Product What is the Aerohive s Free Bonjour Gateway?
PassTest. Bessere Qualität, bessere Dienstleistungen!
PassTest Bessere Qualität, bessere Dienstleistungen! Q&A Exam : VCP510 Title : VMware Certified Professional on VSphere 5 Version : Demo 1 / 7 1.Which VMware solution uses the security of a vsphere implementation
VMware vcenter Update Manager Administration Guide
VMware vcenter Update Manager Administration Guide Update 1 vcenter Update Manager 4.0 This document supports the version of each product listed and supports all subsequent versions until the document
VMware Auto Deploy Administrator s Guide
VMware Auto Deploy Administrator s Guide VMware Auto Deploy Administrator s Guide You can find the most up-to-date technical documentation on the VMware Web site at: http://www.vmware.com/support/ The
Thinspace deskcloud. Quick Start Guide
Thinspace deskcloud Quick Start Guide Version 1.2 Published: SEP-2014 Updated: 16-SEP-2014 2014 Thinspace Technology Ltd. All rights reserved. The information contained in this document represents the
Certification Guide. The Official VCP5. vmware* press. Bill Ferguson. Upper Saddle River, NJ Boston Indianapolis San Francisco.
The Official VCP5 Certification Guide Bill Ferguson vmware* press Upper Saddle River, NJ Boston Indianapolis San Francisco New York Toronto Montreal London Munich Paris Madrid Cape Town Sydney Tokyo Singapore
Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance
Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance This white paper compares the performance of blade-to-blade network traffic between two enterprise blade solutions: the Dell
VMware ESXi 5.0 Installation and RWC2 Tips and Tricks
VMware ESXi 5.0 Installation and RWC2 Tips and Tricks This document introduces the details of how to install VMware ESXi 5.0 Operating System onto an Intel RAID controller and how to use Intel RAID Web
Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server
Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server How to deploy Converged Networking with VMware ESX Server 3.5 Using Emulex FCoE Technology Table of Contents Introduction...