INDEX 02 : CABLE LADDERS

Size: px
Start display at page:

Download "INDEX 02 : CABLE LADDERS"

Transcription

1 02-01 INDEX 02 : CABLE LADDERS Part No. Part No. Part No. Part No. Part No. ACS ORIGINALSTRUT ; CABLE LADDER - STEEL GENERAL INFORMATION LGBE8O LGTE LGER LGLR5O Cable Tray System LGBE8O LGTE LGER LGLR5O General Info LGBE8O LGTE LGER LGLR5O General Info LGBE8O LGTE8O LGER General Info LGBE8O LGTE8O LGER LGLR Accessory Supports CROSS 12B 16A 20B 20C LGTE8O LGER8O LGLR Accessory Supports LGCE LGTE8O LGER8O LGLR NEMA 12B LADDER - STEEL LGCE LGTE8O LGER8O LGLR LGST LGCE IN. RISER 12B 16A 20B 20C LGER8O LGLR LGST LGCE LGIR LGER8O LGLR LGST LGCE LGIR STR. REDUCER 12B 16A 20B 20C LGLR9O LGST LGCE4O LGIR LGSR LGLR9O LGST LGCE4O LGIR LGSR LGLR9O NEMA 16A LADDER - STEEL LGCE4O LGIR LGSR LGLR9O LGST50RI LGCE4O LGIR4O LGSR LGLR9O LGST5200RI LGCE4O LGIR4O LGSR LGLR9O LGST5300RI LGIR4O LGSR LGST5450RI LGCE LGIR4O LGSR4O LGLR LGST5600RI LGCE LGIR4O LGSR4O LGLR LGST50RO LGCE LGSR4O LGLR LGST5200RO LGCE LGIR LGSR4O LGLR LGST5300RO LGCE LGIR LGSR4O LGLR LGST5450RO LGCE5O LGIR LGSR4O LGLR LGST5600RO LGCE5O LGIR LGLR8O NEMA 20B LADDER - STEEL LGCE5O LGIR LGSR LGLR8O LGST90RI LGCE5O LGIR5O LGSR LGLR8O LGST9200RI LGCE5O LGIR5O LGSR LGLR8O LGST9300RI LGIR5O LGSR LGLR8O LGST9450RI LGCE LGIR5O LGSR LGLR8O LGST9600RI LGCE LGIR5O LGSR R REDUCERS 12B 16A 20B 20C LGST90RO LGCE LGSR5O LGRR LGST9200RO LGCE LGIR LGSR5O LGRR LGST9300RO LGCE LGIR LGSR5O LGRR LGST9450RO LGCE9O LGIR LGSR5O LGRR LGST9600RO LGCE9O LGIR LGSR5O LGRR NEMA 20C LADDER - STEEL LGCE9O LGIR LGSR5O LGRR LGST80RI 02 - LGCE9O LGIR9O LGRR4O LGST8200RI 02 - LGCE9O LGIR9O LGSR LGRR4O LGST8300RI 02 - LGIR9O LGSR LGRR4O LGST8450RI 02 - LGCE LGIR9O LGSR LGRR4O LGST8600RI 02 - LGCE LGIR9O LGSR LGRR4O LGST80RO 02 - LGCE LGSR LGRR4O LGST8200RO 02 - LGCE LGIR LGSR LGST8300RO 02 - LGCE LGIR LGSR9O LGRR LGST8450RO 02 - LGCE8O LGIR LGSR9O LGRR LGST8600RO 02 - LGCE8O LGIR LGSR9O LGRR BEND 12B 16A 20B 20C LGCE8O LGIR LGSR9O LGRR LGBE LGCE8O LGIR8O LGSR9O LGRR LGBE LGCE8O LGIR8O LGSR9O LGRR LGBE TEE 12B 16A 20B 20C LGIR8O LGRR5O LGBE LGTE LGIR8O LGSR LGRR5O LGBE LGTE LGIR8O LGSR LGRR5O LGBE4O LGTE EX. RISER 12B 16A 20B 20C LGSR LGRR5O LGBE4O LGTE LGER LGSR LGRR5O LGBE4O LGTE LGER LGSR LGRR5O LGBE4O LGTE4O LGER LGSR LGBE4O LGTE4O LGER LGSR8O LGRR LGTE4O LGER LGSR8O LGRR LGBE LGTE4O LGER4O LGSR8O LGRR LGBE LGTE4O LGER4O LGSR8O LGRR LGBE LGER4O LGSR8O LGRR LGBE LGTE LGER4O LGSR8O LGRR LGBE LGTE LGER4O L REDUCERS 12B 16A 20B 20C LGRR9O LGBE5O LGTE LGLR LGRR9O LGBE5O LGTE LGER LGLR LGRR9O LGBE5O LGTE LGER LGLR LGRR9O LGBE5O LGTE5O LGER LGLR LGRR9O LGBE5O LGTE5O LGER LGLR LGRR9O LGTE5O LGER LGLR LGBE LGTE5O LGER5O LGLR4O LGRR LGBE LGTE5O LGER5O LGLR4O LGRR LGBE LGER5O LGLR4O LGRR LGBE LGTE LGER5O LGLR4O LGRR LGBE LGTE LGER5O LGLR4O LGRR LGBE9O LGTE LGLR4O LGRR LGBE9O LGTE LGER LGRR8O LGBE9O LGTE LGER LGLR LGRR8O LGBE9O LGTE9O LGER LGLR LGRR8O LGBE9O LGTE9O LGER LGLR LGRR8O LGTE9O LGER LGLR LGRR8O LGBE LGTE9O LGER9O LGLR LGRR8O LGBE LGTE9O LGER9O LGLR LGBE LGER9O LGLR5O LGBE LGTE LGER9O LGLR5O LGBE LGTE LGER9O LGLR5O T: +66(38) F: +66(38) info@niedax.co.th ACS ORIGINALSTRUT ; Reserves the right to change product designs or specifications without prior notice

2 02-02 INDEX 02 : CABLE LADDERS Part No. Part No. Part No. Part No. Part No. ACS ORIGINALSTRUT ; CABLE LADDER - STEEL & ALUMINIUM COVER STR.12B 16A 20B 20C OLD DON BRACKET INTERFACE SPACER CLGST CLGERO LGDB12B LGINFSPC LAL8ST CLGST CLGERO LGDB16A DROP-OUT STR.COVER-ALUMINIUM CLGST CLGERO LGDB20B J OOK COVER CLAMP CLALST CLGST CLGERO LGDB20C LGJC CLALST CLGST CLGERO NEMA LADDER ACCESSORIES- LGJC CLALST CLGST0RO STR.REDUCERS COVER S LGJC CLALST CLGST200RO CLGSR S LGJC CLALST CLGST300RO CLGSR P LGJC COVER PKD. STR.-ALUMINIUM CLGST450RO CLGSR RMSM LGJC CLALPK CLGST600RO CLGSR F LGJC CLALPK COVER PKD. STR. CLGSR P LGJC CLALPK CLGPK CLGSRO CB LGJC CLALPK CLGPK CLGSRO N LGJC CLALPK CLGPK CLGSRO S LGJC VENTILATED COVER-ALUMINIUM CLGPK CLGSRO P LGJC CLALVS CLGPK CLGSRO RMSM LGJC CLALVS CLGPK0RO L REDUCERS COVER F LGJC CLALVS CLGPK200RO CLGLR P LGJC CLALVS CLGPK300RO CLGLR BLIND END PLATE LGJC CLALVS CLGPK450RO CLGLR LGEP LGJC CABLE LADDER ACCESSORIES CLGPK600RO CLGLR LGEP LGJC ALUMINIUM VENTILATED COVER CLGLR LGEP LGJC BEND-AL CLGVS CLGLRO LGEP LGJC LALBE CLGVS CLGLRO LGEP COVER CLIPS LALBE CLGVS CLGLRO LGEP LS6CVC12B LALBE CLGVS CLGLRO LGEP LS6CVC16A LALBE CLGVS CLGLRO LGEP LS6CVC20B LALBE CLGVS0RO R REDUCERS COVER LGEP LS6CVC20C LALBE CLGVS200RO CLGRR LGEP Z OLD DON CLAMP LALBE CLGVS300RO CLGRR LGEP LGZC LALBE CLGVS450RO CLGRR LGEP LGZC LALBE CLGVS600RO CLGRR LGEP LGZC LALBE BEND COVER CLGRR LGEP LGZC LALBE CLGBE CLGRRO LGEP LALBE CLGBE CLGRRO LGEP SQ.OLD DON LALBE CLGBE CLGRRO LGEP LGSQ LALBE CLGBE CLGRRO LGEP LALBE CLGBE CLGRRO LGEP COVER STRAPS COVER BEND-AL CLGBEO REDUCERS PLATE LGEP LGCVS CLALBE CLGBEO LGRP STR. SPLICE PLATE LGCVS CLALBE CLGBEO LGRP LGSSP LGCVS CLALBE CLGBEO LGRP LGSSP LGCVS CLALBE CLGBEO LGRP LGSSP LGCVS CLALBE CROSS COVER LGRP LGSSP CROSS-AL CLGCE LADDER SEPARATOR LGCVS LALCE CLGCE LGRP LGSEP LGCVS LALCE CLGCE LGRP LGSEP LGCVS LALCE CLGCE LGRP LGSEP LGCVS LALCE CLGCE LGRP LGSEP LGCVS LALCE CLGCEO LGRP LADDER SEPARATOR LALCE CLGCEO IT CLAMP LGCVS LALCE CLGCEO LGRP LGSEPCP LGCVS LALCE CLGCEO LGRP INSTRUMENT OODS LGCVS LALCE CLGCEO LGRP INSTRUMENT - LGCVS LALCE TEE COVER LGRP STANCIONS LGCVS LALCE CLGTE LGRP LADDER ACCESSORIES LALCE CLGTE CONNECTOR LGCVS LALCE CLGTE LGRP OR SPLICE PLATE LGCVS LALCE CLGTE LGRP LGSP LGCVS LALCE CLGTE LGRP LGSP LGCVS COVER CROSS-AL CLGTEO LGRP LGSP LGCVS CLALCE CLGTEO LGRP LGSP CLALCE CLGTEO SPLICE PLATE SPLICE PLATE 90 o CABLE LADDER ALUMINIUM CLALCE CLGTEO LGSSP12B LG90S GENERAL INFO CLALCE CLGTEO LGSSP16A LG90S CABLE LADDER ALUMINIUM CLALCE INTERNAL RISER COVER LGSSP20B LG90S CLGIR LGSSP20C LG90S LAL5ST TEE-AL CLGIR INGED VERTICAL SPLICE VER SPLICE PLATE LAL5ST LALTE CLGIR LGVSP12B LGVSP LAL5ST LALTE CLGIR LGVSP16A LGVSP LAL5ST LALTE CLGIR LGVSP20B LGVSP LAL5ST LALTE CLGIRO LGVSP20C LGVSP LALTE CLGIRO INGED ORIZONTAL SPLICE EXP SPLICE PLATE LAL7ST LALTE CLGIRO LGSP12B LGESP LAL7ST LALTE CLGIRO LGSP16A LGESP LAL7ST LALTE CLGIRO LGSP20B LGESP LAL7ST LALTE EXTERNAL RISER COVER LGSP20C LGESP LAL7ST LALTE CLGER DIVIDER STRIP DIVIDER STRIP 150 LALTE CLGER LGDVS12B LGDVS LAL8ST LALTE CLGER LGDVS16A LGDVS LAL8ST LALTE CLGER LGDVS20B LGDVS LAL8ST LALTE CLGER LGDVS20C LGDVS LAL8ST LALTE T: +66(38) F: +66(38) info@niedax.co.th ACS ORIGINALSTRUT ; Reserves the right to change product designs or specifications without prior notice

3 02-03 INDEX 02 : CABLE LADDERS Part No. Part No. Part No. Part No. Part No. ACS ORIGINALSTRUT ; CABLE LADDER - STEEL & ALUMINIUM COVER TEE-AL CLALTE CLALRR LALRP USL USLR CLALTE LALRP USL USLR CLALTE L REDUCER - AL LALRP USL USLR CLALTE LALLR LALRP USL USLR CLALTE LALLR LALRP USL USLR IN. RISER-AL LALLR LALRP USL USLR LALIR LALLR USL USLR LALIR LALLR LALRP USL USLR LALIR LALLR LALRP USL USLR LALIR LALLR LALRP USL USLR LALIR LALLR LALRP VERTICAL TEE (USLE) TEE (USLT) LALIR LALLR LALRP USLE USLT LALIR LALLR USLE USLT LALIR LALLR COVER CLAMP USLE USLT LALIR LALLR USLE USLT LALIR COVER REDUCER L. - AL LALCVC USLE USLT LALIR CLALLR USLE USLT LALIR CLALLR LALCVC USLE USLT LALIR CLALLR USLE USLT LALIR CLALLR LALCVC USLE USLT LALIR Z OLD DON CAMP USLE USLT COVER IN. RISER-AL ACCESSORIES AND 0 USLE USLT CLALIR FASTENERS - ALUMUNIUM LALZC USLE USLT CLALIR USLE USLT CLALIR BLIND END PLATE - AL LALZC USLE USLT CLALIR LALEP USLE USLT CLALIR LALEP LALZC USLE USLT EX. RISER-AL LALEP USLE USLT LALER LALEP DIVIDER STRIP USLE USLT LALER LALEP LALDVS USLE USLT LALER LALEP LALDVS USLE USLT LALER LALEP LALDVS USLE USLT LALER LALEP COVER CLIPS USLE USLT LALER LALEP LS6CVC12A USLE USLT LALER LALEP LS6CVC16A USLE USLT LALER LALEP LS6CVC20A USLE USLT LALER LALEP USLE USLT LALER LALEP SQ.OLD DON-AL USLE USLT LALER LALEP LALSQ O BEND (USLB) LALER LALEP USLB Straight Coupler LALER RIGID OLD DON BRACKET-AL USLB USLSC LALER LADDER-ALUMUNIUM LALRG USLB USLSC LALER ACCESSORIES USLB USLSC Vertical inged ST. SPLICE PLATE COVER EX. RISER-AL INTERFACE SPACER-AL USLB coupler CLALER LALINFSPC USLB USLVC CLALER USLB USLVC CLALER LALSSP COVER STRAPS USLB USLVC CLALER LS6CVS USLB OLD DON CLAMP CLALER LALSSP LS6CVS USLB USLDC STR. REDUCER - AL LADDER SEPARATOR LS6CVS USLB USLDC LALSR LS6CVS USLB USLDC LALSR LALSEP LS6CVS USLB DIVIDER STRIP LALSR USLB USLDIV LALSR LALSEP LS6CVS USLB USLDIV LALSR LS6CVS USLB USLDIV LALSR LALSEP LS6CVS USLB ROUND EAD BOLT LALSR SPLICE PLATE 90 O LS6CVS USLB NBPM LALSR LS6CVS USLB NBPM LALSR LAL90S USLB NBPM LALSR LS6CVS USLB NBPM LALSR LAL90S LS6CVS USLB NM LALSR LS6CVS USLB FM COVER STR.REDUCER -AL LAL90S LS6CVS USLB SM CLALSR ORI. SPLICE PLATE LS6CVS USLB CLALSR USLB FRP CABLE LADDER & CLALSR LALSP MARINE LADDER - STEEL USLB ACCESSORIES CLALSR MARINE LADDER (USL) 90 O RISER (USLR) CABLE LADDER STR R REDUCER - AL LALSP USL USLR CABLE LADDER STR. LALRR USL USLR IT COVER LALRR LALSP USL USLR ORI. BEND LALRR USL USLR ORI. TEE LALRR VER.SPLICE PLATE USL USLR IN.VER. BEND LALRR USL USLR OUT.VER. BEND LALRR LALVSP USL USLR ORI. CROSS LALRR USL USLR STR. REDUCER LALRR LALVSP USL USLR L/R REDUCER LALRR USL USLR SPLICE PLATE LALRR LALVSP USL USLR LALRR USL USLR LALRR REDUCER PLATE USL USLR COVER R REDUCER - AL LALRP USL USLR CLALRR LALRP USL USLR CLALRR LALRP USL USLR CLALRR LALRP USL USLR T: +66(38) F: +66(38) info@niedax.co.th ACS ORIGINALSTRUT ; Reserves the right to change product designs or specifications without prior notice

4 02-01 ACS ORIGINALSTRUT ; CABLE LADDER, CABLE TRAY, DUCT & TRUNKING SYSTEMS Straight Length (Cable Ladder) o orizontal Elbow 21 Adj. Vertical Connector 2 Straight Length (Cable Ladder) o Internal Vertical Elbow 22 Adj. orizontal Connector 3 Straight Length (Cable Tray) o External Vertical Elbow 23 Reducer Plate 4 Straight Length (Duct & Trunking) 14 orizontal Tee 24 Offset Reducer 5 Flat Covers 15 Cable Duct Tee Connector o Splice Plate 6 Internal 90 o Vertical Elbow 16 orizontal Tee 26 Straight Divider 7 External 90 o Vertical Elbow 17 orizontal Cross 27 Cover Connector Clip 8 Cable Duct 90 o Internal Elbow 18 Straight Reducers 28 Cover Connector Strap 9 Cable Duct 90 o External Elbow 19 Splice Plate 29 Dropout 45 o orizontal Elbow 20 Expansion Connector 30 Blind End.

5 02-02 ACS ORIGINALSTRUT ;CABLE LADDER GENERAL INFORMATION ACS ORIGINALSTRUT ; manufacture and market the largest range of cable ladder systems for the global Electrical Industry, this extensive range of cable ladder support systems includes a comprehensive range of steel, aluminium and FRP cable ladders load rated to NEMA Standard VE1-2009, steel cable ladders can be manufactured to side-rail in or side-rail out configuration depending on project requirements In cases where extremely high corrosion resistance is required, stainless steel and FRP cable ladder systems are available, all our cable ladder systems are complemented with a complete range of accessories: orizontal Bends, Internal and External Risers, Tees, Crosses, Reducers, inged orizontal and Vertical Splices, Adjustable Risers, Covers, Divider Strip, Dropouts, Adjustable Cantilever Support, Brackets and Cable Clamps ACS ORIGINALSTRUT ; Cable Ladder - STEEL eight Cable laying depth Length idths 75, 0, 130, 150 MM 54, 79, 9, 129 MM 3 M or 6 M 0,200,300,450,600,900 MM ACS ORIGINALSTRUT ; Cable Ladder - ALUMINIUM eight Cable laying depth Length idths 0, 125, 150 MM 77,0,129 MM 3 M or 6 M 0,200,300,450,600,900 MM PRODUCT CABLE LADDER These ladders carry large cables with high voltage power carrying capacity, used on all major industrial sites. Ladders come in various strengths depending on loading capacity and in either 3 or 6m lengths, materials used, Steel ot Dipped Galvanised, Aluminium, Stainless steel SS304 / SS316, Epoxy painted steel

6 02-03 ACS ORIGINALSTRUT ; CABLE LADDER NEMA RATED GENERAL INFORMATION The following notes are presented in order to assist users to achieve maximum economy and convenience with the installation of cable support systems, as each application will have its own particular conditions and requirements it is recommended that the services of ACS ORIGINALSTRUT ; sales personnel and engineering team be engaged, especially in the early stages of any major project, so that the best overall result can be achieved Standard Sizes Standard ladder widths are 0mm,200mm, 300mm,450mm, 600mm and 900mm, being the inside dimension between side-rails and is the maximum width available for carrying cables. Straight lengths are 3m or 6m long. Standard rung spacing on all systems is 300mm nominal Each system includes a full range of standard accessories, with a nominal radius of 300mm, 450mm and 600mm, depending on the system load class. Non-standard ladder widths and accessory radii can be manufactured against order Load Capacity a) Cable Load - Because cable density remains fairly constant in a total installation, the widest ladders carry the most load, and each smaller width carries proportionately less load however, the load carrying capacity of any class of ladder is independent of the width For details on how safe working loads are determined, refer to the NEMA VE Standard and to published load graphs for allowable loads of each ladder type b) Fixed Ladder Spans - It is commonly found that the building structure supporting cable ladders will dictate the span, but it is still possible to exercise some choice. here the cabling is heaviest, and this is not usually extensive, it is possible to use (say) two 300mm wide ladders side by side instead of one 600mm wide, in order to select a lighter category of ladder for the total project, it is often inconvenient to use more than one ladder category in the same installation c) Varying the Spans - here the structure does not dictate the ladder span, the heaviest cable runs could be supported more frequently, again enabling a lighter category of ladder to be chosen Cable Laying Depth Each of the cable and tray systems has a different cable laying depth, it is a general rule that the shallower the ladder, the lower cost per metre and the more frequently it needs supports. It is sometimes found that the lightest, most economical ladders are excluded from consideration solely because a particular minimum cable laying depth is required and has been specified accordingly Deflection Cable ladders are essentially structural members designed to strength requirements only and are required to support pliable load elements therefore, the control of deflection is not necessary for durability or stability reasons and can probably only be justified on purely aesthetic grounds. If normally accepted deflection limits such as 1/360th of span are imposed, the resultant cable ladder will be grossly overdesigned and correspondingly expensive There may still be locations where the designer wishes to limit visual deflection for example, prestige areas which may be open to public view or where the ladder is installed at eye level and deflection is accentuated, if these conditions exist, it is recommended that closer support spacings be used only in those important locations (to control visual deflection) and normal support spacings elsewhere (for economy). A maximum of 1/180th of span, when deflection is determined from the graphs published in this catalogue, should prove a satisfactory limit for visual deflection Otherwise, wherever overall economy is the principal consideration, no limits should be placed on deflection, this does not mean that deflection will be excessive but simply that a typically acceptable installation will result and optimum economy will be attained

7 02-04 ACS ORIGINALSTRUT ; CABLE LADDER NEMA RATED GENERAL INFORMATION Material Selection Often the most difficult decision to be made is the selection of material, because it involves the most costsensitive of compromises, material choice is directly related to service life and the longer the required life the more expensive will be the materials, the cost of these materials also must be considered as an equation of initial investment versus maintenance costs and eventual replacement Because service conditions for cable ladders can vary over an enormously wide range, even within a single installation, it is impossible to write down any hard and fast rules on the subject of corrosion and expected lifespan, the following may be considered a guide as to what can be expected from the various materials and finishes currently available for cable support systems a) Galvanised Steel ot-dipped galvanised steel (after fabrication) is a common selection, as it is economical to purchase and suitable for most conditions of outdoor exposure, for indoor applications, or anywhere that is essentially free from moisture, galvanised ladders can be considered to have an indefinite life. That is, they should last as long as the plant, building, cabling or equipment which they service On a typical industrial or processing plant installation, exposed to weather, moisture and airborne industrial pollution, a basic life of approximately twenty to twenty five years can be expected. This is not to say that the ladder will be completely corroded in that time but it is the probable life of the corrosion protecton finish, beyond that time rapid decay can be expected and maintenance costs will increase substantially in order to keep the ladders serviceable The twenty to twenty five years life quoted here should be adjusted up or down depending on the circumstances, for example if installed near the coast, the effect of salt laden air may shorten the expected life, also galvanising is sensitive to some chemicals, especially sulphurous compounds, which may be intrinsic to plant operations where the ladder is installed. Correspondingly, a longer life will be expected in lighter industrial situations and if drier conditions exist b) Aluminium Aluminium is also a popular choice of material for cable ladders, most frequently it is selected because of its excellent performance in marine environments such as is found on wharves, coal loaders or similar Port Facilities where salt spray or salt laden atmosphere is present. Another reason for using aluminium is that it offers a long maintenance free life which is important in cases where access for future painting or repairs may be costly and difficult For any given load class or capacity, aluminium cable ladders are more expensive than their galvanised steel counterparts, aluminium ladders can also be expected to have a greater deflection than an equivalent steel system. On the other hand, they are lighter, more readily handled and are easy to work with, resulting in faster installation and therefore lower installation cost Aluminium cable ladders can be expected to have a lifespan well in excess of twenty five years in most industrial or marine applications, the exception would be in the case of a local concentration of chemicals which are detrimental to aluminium, alkaline compounds or fumes is a common example but if any doubt exists, the advice of aluminium suppliers should be sought c) Stainless Steel Stainless Steel is sometimes considered as a material for cable ladders, usually where extremely high corrosion resistance, coupled with difficulty of servicing after installation and a high degree of reliability are essential requirements, offshore oil & gas platforms may be one example where these conditions exist

8 02-05 ACS ORIGINALSTRUT ; NEMA CABLE LADDER - ACCESSORY SUPPORTS Accessories for all Unistrut cable ladder systems are available in six standard widths-0, 200, 300, 450, 600 or 900mm, System Std. Radius 12B SCL and 12A ACL 300mm 16A SCL and 20A ACL 450mm 20B, 20C SCL and 20C ACL 600mm Fixed bends and Internal or External Risers are readily avilable with a 90 o angle, other angles (30 o,45 o or 60 o ) and other radii (300,450,600 or 900mm) can be supplied on special request, the radii also applies to Tees and Crosses All support locations below are in accordance with NEMA standard VE TEES & CROSSES For smaller radius accessories and / or lighter loaded ladders, the support methods shown may be reduced or even eliminated This is best determined at the point of installation or consult your local Unistrut Service Centre RISER & BENDS For narrower ladders and smaller angles, the bend centre support may be deleted STRAIGT OR OFFSET REDUCER Staight Reducer plus left and right hand offset reducers are available for all Unistrut Cable Ladder systems Major idth:a 200,300,450,450,600,900 Minor idth:b 0,200,300,450 Reducer splice plates are available for all ladder systems

9 02-06 ACS ORIGINALSTRUT ; NEMA CABLE LADDER - ACCESSORY SUPPORTS CABLE LADDER ACCESSORY SUPPORTS - FASTENERS Fasteners required for fixing of steel and aluminium cable ladder systems: Fastener Quantities - Steel Cable Ladders Splice Plates Description Part No. Quantity Straight, Reducer,/,/V 12B Splice Screw (EZP) S16 2 per Splice Plate 16A, 16A-RI, 20B, 20B-RI Splice Screw (DG) CB20 4 per Splice Plate Splice Nut (DG) N 20C, 20C-RI Splice Screw (DG) CB20 8 per Splice Plate Splice Nut (DG) N Accessories 12B Splice Screw (EZP) S16 4 per Bend, Riser or Reducer 6 per Tee, 8 per Cross 16A, 16A-RI, 20B, 20B-RI Splice Screw (DG) CB20 8 per Bend, Riser or Reducer Splice Nut (DG) N 12 per Tee, 24 per Cross 20C, 20C-RI Splice Screw (DG) CB20 16 per Bend, Riser or Reducer Splice Nut (DG) N 24 per Tee, 32 per Cross Fastener Quantities - Aluminium Cable Ladders Splice Plates Description Part No. Quantity 16A, 20B Splice Screw (SS316) S16 4 per Splice Plate 20C Splice Screw (SS316) CB20 4 per Splice Plate Splice Nut (Nyloc SS316) N Accessories 20A Splice Screw (SS316) S16 8 per Bend, Riser or Reducer 12 per Tee, 16 per Cross 20C Splice Screw (SS316) CB20 8 per Bend, Riser or Reducer Splice Nut (Nyloc SS316) N 12 per Tee, 16 per Cross

10 02-07 ACS ORIGINALSTRUT ; NEMA 12B CABLE LADDER - STEEL Technical Data Cable Laying Depth 54mm Loading Data Basic Load Capacity 131kg/lin.m on 3.6m span 424 kg/lin.m on 2.0m span Length 3m & 6m Rung Spacing 300mm nominal Finish ot Dipped Galvanised, Stainless Steel 304 / 316 or painted Parts List 6000 Dim Part No / 300 "" SAP Des. 0 LGST40RI 200 LGST4200RI 300 LGST4300RI LGST4450RI LGST4600RI 1 0 LGST40RO 200 LGST4200RO LGST4300RO LGST4450RO LGST4600RO Note : Fire Rated to AS/NZS3013:1995 Appendix B - Classification S5X. Refer to your local Service Centre for load ratings and correct installation procedures. Allowable Load Graph * Splice plate & Fixing screws are not included (order separately) Deflection Graph Allowable loads are determined generally in accordance with NEMA Standard VE1 and verified by testing Safety Factor = 1.5 on collapse load for single span Deflections shown apply to the end-bays (ie.worst case) of a continuous ladder run, to find deflection of a single span multiply by 2.5

11 02-08 ACS ORIGINALSTRUT ; NEMA 16B CABLE LADDER - STEEL Technical Data Cable Laying Depth 79mm Loading Data Basic Load Capacity 79 kg/lin.m on 6m span 470 kg/lin.m on 3m span Length 3m & 6m Rung Spacing 300mm nominal Finish ot Dipped Galvanised, Stainless Steel 304 / 316 or Painted Parts List Dim Type Part No / "" SAP Des. 0 Rail In LGST50RI 200 Rail In LGST5200RI 300 Rail In LGST5300RI 450 Rail In LGST5450RI 600 Rail In LGST5600RI "RI"-Rail In Series 0 Rail Out LGST50RO 200 Rail Out LGST5200RO 300 Rail Out LGST5300RO 450 Rail Out LGST5450RO 600 Rail Out LGST5600RO "RO"-Rail Out Series Note : Fire rated to AS/NZS3013:1995 Appendix B - Classification S5X. Refer to your local Service Centre for load ratings and correct installation procedures. * Splice plate & Fixing screws are not included (order separately) 0 79 Allowable Load Graph Deflection Graph Allowable loads are determined generally in accordance with NEMA Standard VE1 and verified by testing. Safety Factor = 1.5 on collapse load for single span Deflections shown apply to the end-bays (ie.worst case) of a continuous ladder run. To find deflection of a single span, multiply by 2.5

12 02-09 ACS ORIGINALSTRUT ; NEMA 20B CABLE LADDER - STEEL Technical Data Cable Laying Depth 9 mm Loading Data Basic Load Capacity kg/lin.m on 6m span 573 kg/lin.m on 3m span Length 3m & 6m Rung Spacing 300mm nominal Finish ot Dipped Galvanised, "RI"-Rail In Series Stainless Steel 304 / 316 or Painted Parts List Dim Type Part No / "" SAP Des. 0 Rail In LGST90RI 200 Rail In LGST9200RI 300 Rail In LGST9300RI 450 Rail In LGST9450RI 600 Rail In LGST9600RI Rail Out LGST90RO 200 Rail Out LGST9200RO 300 Rail Out LGST9300RO 450 Rail Out LGST9450RO 600 Rail Out LGST9600RO Note : Fire rated to AS/NZS3013:1995 "RO"-Rail Out Series Appendix B - Classification S5X. Refer to your local Service Centre for load ratings and correct installation procedures * Splice plate & Fixing screws are not included (order separately) 32 Allowable Load Graph Deflection Graph Allowable loads are determined generally in accordance with NEMA Standard VE1 and verified by testing. Safety Factor = 1.5 on collapse load for single span Deflections shown apply to the end-bays (ie.worst case) of a continuous ladder run. To find deflection of a single span, multiply by 2.5

13 02 - ACS ORIGINALSTRUT ; NEMA 20C CABLE LADDER - STEEL Technical Data Cable Laying Depth 129 mm Loading Data Basic Load Capacity 168 kg/lin.m on 6m span 653 kg/lin.m on 3m span Length 3m & 6m Rung Spacing 300mm nominal Finish ot Dipped Galvanised, Stainless Steel 304 / 316 or Painted Parts List Dim Type Part No / "" SAP Des. 0 Rail In LGST80RI 200 Rail In LGST8200RI 300 Rail In LGST8300RI 450 Rail In LGST8450RI 600 Rail In LGST8600RI Rail Out LGST80RO 200 Rail Out LGST8200RO 300 Rail Out LGST8300RO 450 Rail Out LGST8450RO 600 Rail Out LGST8600RO Note : Fire rated to AS/NZS3013:1995 Appendix B - Classification S5X. Refer to your local Service Centre for load ratings and correct installation procedures. * Splice plate & Fixing screws are not included (ordered separately) Allowable Load Graph Deflection Graph Allowable loads are determined generally in accordance with NEMA Standard VE1 and verified by testing. Safety Factor = 1.5 on collapse load for single span Deflections shown apply to the end-bays (ie.worst case) of a continuous ladder run. To find deflection of a single span, multiply by 2.5

14 02-11 ACS ORIGINALSTRUT ; NEMA CABLE LADDER ACCESSORIES- STEEL Steel Shaped Accessories - BENDS, CROSSES with Cover FLAT BEND 90 o ith Flange FLAT BEND 90 o ithout Flange Radius idth eight R FLAT BEND 90 O LGBE40 LGBE4O ith Flange LGBE4200 LGBE4O LGBE4300 LGBE4O LGBE4450 LGBE4O LGBE4600 LGBE4O LGBE50 LGBE5O LGBE5200 LGBE5O LGBE5300 LGBE5O LGBE5450 LGBE5O O R 150 LGBE5600 LGBE5O LGBE90 LGBE9O LGBE9200 LGBE9O LGBE9300 LGBE9O ithout Flange LGBE9450 LGBE9O LGBE9600 LGBE9O LGBE80 LGBE8O LGBE8200 LGBE8O LGBE8300 LGBE8O LGBE8450 LGBE8O LGBE8600 LGBE8O O R 150 Radius idth eight FLAT COSS 90 o ith Flange FLAT COSS 90 o ithout Flange R LGCE40 LGCE4O LGCE4200 LGCE4O LGCE4300 LGCE4O LGCE4450 LGCE4O LGCE4600 LGCE4O FLAT CROSS 90 O ith Flange LGCE50 LGCE5O LGCE5200 LGCE5O LGCE5300 LGCE5O LGCE5450 LGCE5O LGCE5600 LGCE5O LGCE90 LGCE9O LGCE9200 LGCE9O LGCE9300 LGCE9O LGCE9450 LGCE9O LGCE9600 LGCE9O LGCE80 LGCE8O LGCE8200 LGCE8O LGCE8300 LGCE8O LGCE8450 LGCE8O LGCE8600 LGCE8O ithout Flange O R idths over 600mm Degree is 30,45,60 also available on request - Fixing ardware for cable ladder systems must be ordered O R 150 separately Finish ot Dip Galanvised, Stainless Steel 304 / 316 or Painted

15 02-12 ACS ORIGINALSTRUT ; NEMA CABLE LADDER ACCESSORIES- STEEL Steel Shaped Accessories - TEES, RISER with COVER TEE 90 o ith Flange Radius idth eight TEE 90 o ithout Flange R LGTE40 LGTE4O LGTE4200 LGTE4O LGTE4300 LGTE4O LGTE4450 LGTE4O LGTE4600 LGTE4O ORIZONTAL TEE 90 o ith Flange LGTE50 LGTE5O LGTE5200 LGTE5O LGTE5300 LGTE5O LGTE5450 LGTE5O O R 150 LGTE5600 LGTE5O LGTE90 LGTE9O ithout Flange LGTE9200 LGTE9O LGTE9300 LGTE9O LGTE9450 LGTE9O LGTE9600 LGTE9O LGTE80 LGTE8O LGTE8200 LGTE8O LGTE8300 LGTE8O LGTE8450 LGTE8O LGTE8600 LGTE8O R O 150 INT. RISER 90 o ith Flange INT. RISER 90 o ithout Flange Radius idth eight R INTERNAL RISER - 90 O LGIR40 LGIR4O LGIR4200 LGIR4O ith Flange R 150 LGIR4300 LGIR4O LGIR4450 LGIR4O O LGIR4600 LGIR4O LGIR50 LGIR5O LGIR5200 LGIR5O LGIR5300 LGIR5O LGIR5450 LGIR5O LGIR5600 LGIR5O LGIR90 LGIR9O LGIR9200 LGIR9O ithout Flange LGIR9300 LGIR9O LGIR9450 LGIR9O LGIR9600 LGIR9O LGIR80 LGIR8O LGIR8200 LGIR8O O R LGIR8300 LGIR8O LGIR8450 LGIR8O LGIR8600 LGIR8O idths over 600mm Degree is 30,45,60 also available on request - Fixing ardware for cable ladder systems must be ordered separately - Finish ot Dip Galanvised, Stainless Steel 304 / 316 or Painted

16 02-13 ACS ORIGINALSTRUT ; CABLE LADDER ACCESSORIES- STEEL Steel Shaped Accessories - RISERS & COVER EXT. RISER 90 o ith Flange EXT. RISER 90 o ithout Flange Radius idth eight R EXTERNAL RISER - 90 O LGER40 LGER4O LGER4200 LGER4O LGER4300 LGER4O LGER4450 LGER4O ithout Flange ith Flange LGER4600 LGER4O LGER50 LGER5O LGER5200 LGER5O LGER5300 LGER5O LGER5450 LGER5O LGER5600 LGER5O LGER90 LGER9O LGER9200 LGER9O O R O R 150 LGER9300 LGER9O LGER9450 LGER9O LGER9600 LGER9O LGER80 LGER8O LGER8200 LGER8O LGER8300 LGER8O LGER8450 LGER8O LGER8600 LGER8O STR. REDUCER ith Flange idth idth eight STR. REDUCER ithout Flange a b STRAIGT REDUCER LGSR LGSR4O ith Flange LGSR LGSR4O LGSR LGSR4O LGSR LGSR4O b LGSR LGSR4O LGSR LGSR4O LGSR LGSR5O LGSR LGSR5O LGSR LGSR5O LGSR LGSR5O LGSR LGSR5O a LGSR LGSR5O ithout Flange LGSR LGSR9O LGSR LGSR9O LGSR LGSR9O b LGSR LGSR9O LGSR LGSR9O LGSR LGSR9O LGSR LGSR8O LGSR LGSR8O LGSR LGSR8O LGSR LGSR8O LGSR LGSR8O a LGSR LGSR8O idths over 600mm Degree is 30,45,60 also available on request - Fixing ardware for cable ladder systems must be ordered separately - Finish ot Dip Galanvised, Stainless Steel 304 / 316 or Painted

17 02-14 ACS ORIGINALSTRUT ; CABLE LADDER ACCESSORIES - STEEL Steel Shaped Accessories - REDUCERS & COVER L-REDUCER ith Flange L-REDUCER ithout Flange idth idth eight a b LGLR LGLR4O LGLR LGLR4O LGLR LGLR4O LGLR LGLR4O LGLR LGLR4O LGLR LGLR4O L - REDUCER ith Flange b LGLR LGLR5O LGLR LGLR5O LGLR LGLR5O LGLR LGLR5O LGLR LGLR5O LGLR LGLR5O ithout Flange a LGLR LGLR9O LGLR LGLR9O LGLR LGLR9O LGLR LGLR9O LGLR LGLR9O LGLR LGLR9O b LGLR LGLR8O LGLR LGLR8O LGLR LGLR8O LGLR LGLR8O LGLR LGLR8O LGLR LGLR8O R-REDUCER ith Flange R-REDUCER ithout Flange idth idth eight a b R - REDUCER ith Flange a LGRR LGRR4O LGRR LGRR4O b LGRR LGRR4O LGRR LGRR4O LGRR LGRR4O LGRR LGRR4O LGRR LGRR5O LGRR LGRR5O LGRR LGRR5O a LGRR LGRR5O LGRR LGRR5O ithout Flange LGRR LGRR5O LGRR LGRR9O b LGRR LGRR9O LGRR LGRR9O LGRR LGRR9O LGRR LGRR9O LGRR LGRR9O LGRR LGRR8O LGRR LGRR8O LGRR LGRR8O a LGRR LGRR8O LGRR LGRR8O LGRR LGRR8O idths over 600mm Degree is 30,45,60 also available on request - Fixing ardware for cable ladder systems must be ordered separately - Finish ot Dip Galanvised, Stainless Steel 304 / 316 or Painted

18 02-15 ACS ORIGINALSTRUT ; NEMA CABLE LADDER COVER - STEEL Ladder Cover - STRAIGT LENGTS STR.COVER Rail In STR.COVER Rail Out idth eight COVER STRAIGT CLGST0 CLGST0RO 0 CLGST200 CLGST200RO 200 CLGST300 CLGST300RO 300 CLGST450 CLGST450RO 450 CLGST600 CLGST600RO 600 Type 1 L = 3000mm Note Type 1. > Use for Cover idth 0 to 200 Type 2. > Use for Cover idth 300 to 00 - idths over 600mm available for side Rail In only - Fixing ardware for cable ladder systems must be ordered separately Finish ot Dip Galvanised, Stainless Steel 304 / 316 or Painted Type 2 L = 3000mm Rail In + 5 Rail Out + 45 COVER PEAKED STRAIGT COVER PEAKED Rail In COVER PEAKED Rail Out idth eight COVER PEAKED STRAIGT CLGPK0 CLGPK0RO 0 CLGPK200 CLGPK200RO 200 CLGPK300 CLGPK300RO 300 CLGPK450 CLGPK450RO 450 L = 3000 mm CLGPK600 CLGPK600RO 600 COVER VENTILATED STRAIGT COVER VENTILATED COVER VENTILATED Rail In Rail Out idth eight Rail In Rail Out 15 O O CLGVS0 CLGVS0RO 0 CLGVS200 CLGVS200RO 200 CLGVS300 CLGVS300RO 300 CLGVS450 CLGVS450RO 450 COVER VENTILATED STRAIGT + 45 CLGVS600 CLGVS600RO 600 L = 3000 mm - idths over 600mm available on request - Fixing ardware for cable ladder systems must be ordered separately Finish ot Dip Galvanised, Stainless Steel 304 / 316 or Painted +5 Rail In Rail Out

19 02-16 ACS ORIGINALSTRUT ; NEMA CABLE LADDER COVER - STEEL Ladder Covers Accessories COVER ith Flang COVER ithout Flang BEND COVER idth eight CLGBE0 CLGBEO0 0 CLGBE200 CLGBEO CLGBE300 CLGBEO CLGBE450 CLGBEO CLGBE600 CLGBEO CROSS COVER CLGCE0 CLGCEO0 0 CLGCE200 CLGCEO CLGCE300 CLGCEO CLGCE450 CLGCEO CLGCE600 CLGCEO TEE COVER CLGTE0 CLGTEO0 0 CLGTE200 CLGTEO CLGTE300 CLGTEO CLGTE450 CLGTEO CLGTE600 CLGTEO INTERNAL RISER COVER CLGIR0 CLGIRO0 0 CLGIR200 CLGIRO CLGIR300 CLGIRO CLGIR450 CLGIRO CLGIR600 CLGIRO EXTERNAL RISER COVER CLGER0 CLGERO0 0 CLGER200 CLGERO CLGER300 CLGERO CLGER450 CLGERO CLGER600 CLGERO STRAIGT REDUCER COVER CLGSR0 CLGSRO0 0 CLGSR200 CLGSRO CLGSR300 CLGSRO CLGSR450 CLGSRO CLGSR600 CLGSRO L REDUCER COVER CLGRL0 CLGRLO0 0 CLGRL200 CLGRLO CLGRL300 CLGRLO CLGRL450 CLGRLO CLGRL600 CLGRLO R REDUCER COVER CLGRR0 CLGRRO0 0 CLGRR200 CLGRRO CLGRR300 CLGRRO CLGRR450 CLGRRO CLGRR600 CLGRRO (+5) (+5) FLAT CROSS 90 O COVER ORIZONTAL TEE 90 o COVER FLAT BEND 90 O COVER (+5) (+5) (+5) INTERNAL RISER 90 O COVER (+5) (+5) (+5) STRAIGT REDUCER COVER (+5) (+5) EXTERNAL RISER 90 O COVER (+5) L REDUCER COVER (+5) (+5) R REDUCER COVER - idths over 600mm available on request - Fixing ardware for cable ladder systems must be ordered separately Finish ot Dip Galvanised, Stainless Steel 304 / 316 or Painted (+5) L = 3000mm

20 02-17 ACS ORIGINALSTRUT ; NEMA CABLE LADDER ACCESSORIES - STEEL Steel Shaped Accessories - Reducers REDUCER SPLICE OLD DON BRACKET 16A / 20B / 20C 12B SPLICE PLATES DIVIDER STRIP 12B 16A / 20B 20C INGED ORIZONTAL SPLICE INGED VERTICAL SPLICE Type idth (mm) eight'" Part No. / SPLICE PLATE INGED ORIZONTAL SPLICE REDUCER SPLICE SAP Des. Type Type 12B 0 60 LGRP40 12B LGSSP12B 12B 12B LGRP A LGSSP16A 16A 12B LGRP B LGSSP20B 20B 12B LGRP C LGSSP20C 20C 12B LGRP A 0 84 LGRP50 INGED VERTICAL SPLICE OLD DON BRACKET 16A LGRP5200 Type Type 16A LGRP B LGVSP12B 12B 16A LGRP A LGVSP16A 16A 16A LGRP B LGVSP20B 20B 20B LGRP90 20C LGVSP20C 20C 20B LGRP B LGRP9300 DIVIDER SRTIP 20B LGRP9450 Type 20B LGRP B LGDVS12B 20C LGRP80 16A LGDVS16A 20C LGRP B LGDVS20B 20C LGRP C LGDVS20C 20C LGRP C LGRP8600 Fixing ardware for cable ladder systems must be ordered separately * Finish ot Dip Galvanised, Stainless Steel 304 / 316 or Painted LGSP12B LGSP16A LGSP20B LGSP20C LGDB12B LGDB16A LGDB20B LGDB20C

21 02-18 ACS ORIGINALSTRUT ; NEMA CABLE LADDER ACCESSORIES - STEEL Steel Shaped Accessories - Fasteners SPLICE PLATES Screws and nuts must be ordered separately 12B 16A & 20B 20C OLD DON BRACKET DIVIDER STRIP 12B 3m 16A, 20B & 20C 12B Positioned at any point along ladder length. Brackets provide rigid clamping for all steel systems Used to separate cables of different voltages or circuits. The notched base permits forming to the required shape. Fix at 1m centres Fasteners Type Description 12B Splice Screw S16 12B old Down Bracket Screw S B old Down Bracket Nut P07 12B Divider Strip Screw RMSM B Divider Strip asher F08 12B Divider Strip Nut P06 16A, 20B, 20C Splice Screw CB20 16A, 20B, 20C Splice Nut N 16A, 20B, 20C old Down Bracket Screw S A, 20B, 20C old Down Bracket Nut P 16A, 20B, 20C Divider Strip Screw RMSM A, 20B, 20C Divider Nut asher F08 16A, 20B, 20C Divider Strip Nut P06 Fixing ardware for cable ladder systems must be ordered separately Finish ot Dip Galvanised, Stainless Steel 304 / 316 or Painted

22 02-19 ACS ORIGINALSTRUT ; CABLE LADDER ACCESSORIES Ladder Accessories - END PLATE, SEPARATOR, CONNECTOR, STANCIONS, OODS LADDER BLIND END PLATE LADDER STRAIGT SPLICE PLATE TYP/CAL TYP/CAL 25 LADDER SEPARATOR Round ead Bolt M8x20 SEPARATOR IT CLAMP 3000 L Flat washer M8 300 ex Nut M TYP/CAL 150 TYP/CAL INSTRUMENT STANCIONS INSTRUMENT OODS REQUIRE L PIPE 2" SC.40 SECTION VIE idth eight BLIND END PLATE STRAIGT SPLICE PLATE LADDER SEPARATOR 0 75 LGEP LGEP4200 LGSSP075 LGSEP LGEP LGEP4450 LGSSP0 LGSEP LGEP LGEP50 LGSSP130 LGSEP LGEP LGEP5300 LGSSP150 LGSEP LGEP LGEP LGEP90 INSTRUMENT OODS INSTRUMENT STANCIONS LGEP9200 As per Require As per Require LGEP9300 (Make to order) (Make to order) LGEP LGEP9600 LADDER SEPARATOR IT CLAMP LGEP LGEP8200 LGSEPCP LGEP LGEP8450 Fixing ardware for cable ladder systems must be ordered separately LGEP8600 * Finish ot Dip Galvanised, Stainless Steel 304 / 316 or Painted

23 02-20 ACS ORIGINALSTRUT ; CABLE LADDER ACCESSORIES Ladder Accessories - CONNECTOR ORIZONTAL SPLICE PLATE SPLICE PLATE 90 O A fast and economical method of changing ladder direction where exact site dimensions must be met, Especially suitable where the angle is less that 45 o or larger angles where the cable bending radius is not important, Also provides a flexible alternative to standard accessory sizes and radii, suits all ACS ORIGINALSTRUT ; aluminium cable ladder systems TYP/CAL VERTICAL SPLICE PLATE TYP/CAL 25 EXPANSION SPLICE PLATE Ideal for making changes in vertical level or direction, Easily adapts to exact site dimensions which may otherwise be difficult to achieve with fixed risers, Cables form their own bending radius spanning between adjacent end-rungs, Also used to form adjustable risers providing flexibility to adjust to any site restrictions DIVIDER STRIP INTERFACE SPACER TYP/CAL Divider Strip is used to separate cables of different voltages or circuits, The notched base permits forming to the required shape Used to separate cable ladder and supports in corrosive environments DROP-OUT t 30 Øx20 Slot R150 DROP-OUT for Ladder To suit ladder width 90 O dimensions 60 eight OR SPLICE PLATE SPLICE PLATE 90 O VER SPLICE PLATE EXP SPLICE PLATE eight Part No. / SAP Des. Part No. / SAP Des. Part No. / SAP Des. Part No. / SAP Des. 75 LGSP075 LG90S075 LGVSP075 LGESP LGSP0 LG90S0 LGVSP0 LGESP LGSP130 LG90S130 LGVSP130 LGESP LGSP150 LG90S150 LGVSP150 LGESP DIVIDER STRIP Part No. / SAP Des. LGDVS075 LGDVS0 LGDVS130 LGDVS150 INTERFACE SPACER Part No. / SAP Des. All Systems LGINFSPC DROP-OUT Part No. / SAP Des. To suit ladder width dimensions Fixing ardware for cable ladder systems must be ordered separately * Finish ot Dip Galvanised, Stainless Steel 304 / 316 or Painted

24 02-21 ACS ORIGINALSTRUT ; CABLE LADDER ACCESSORIES Ladder Accessories - CLAMPS Cover Clips Cover Fixing Recommended Spacing For Cover Clips Service Conditions Design ind Ladder width, mm velocity, Vz (AS1170) Up to and including 50m/s 1.2m 1.2m 1.2m 1.2m exposed external locations Cyclonic Areas 65m/s 0.6m 0.8m 1.2m 1.2m Covers are retained in position by means of cover clips as illustrated. Manufactured from high strength steel, these unique clips, which have no thread components to freeze up, are very quickly installed and are also easily removed or replaced at a later date One size of clip for each ladder system suits both straight and accessory covers Cover Straps Z OLD DON CLAMP 26 Application with J-ook M J OOK COVER CLAMP ex Bolt Mx30 SQ. OLD DON CLAMP L1 Flat asher M L ole Ø 12mm Spring Nut M Type COVER CLIPS Part No. / SAP Des. idth eight J OOK COVER CLAMP 12B LS6CVC12B Part No. / SAP Des. 16A LS6CVC16A 0 75 LGJC40 20B LS6CVC20B LGJC C LS6CVC20C LGJC4300 COVER STRAPS LGJC4450 Type Ladder idth LGJC B LGJC50 12B LGJC B LGJC B LGJC B LGJC A LGJC90 16A LGJC A LGJC A LGJC A LGJC B LGJC80 20B LGJC B LGJC B LGJC B LGJC C 0 SQ.OLD DON 20C 200 Part No. / SAP Des. LGSQ C C 450 Fixing ardware for cable ladder systems must be ordered separately 20C 600 Finish ot Dip Galvanised, Stainless Steel 304 / 316, or Aluminium Z OLD DON CLAMP Part No. / SAP Des. LGZC075 LGZC0 LGZC130 LGZC150 Part No. / SAP Des. LGCVS40 LGCVS4200 LGCVS4300 LGCVS4450 LGCVS4600 LGCVS50 LGCVS5200 LGCVS5300 LGCVS5450 LGCVS5600 LGCVS90 LGCVS9200 LGCVS9300 LGCVS9450 LGCVS9600 LGCVS80 LGCVS8200 LGCVS8300 LGCVS8450 LGCVS8600

SECTION 4: Cable Ladder Stainless Steel & Aluminium

SECTION 4: Cable Ladder Stainless Steel & Aluminium SECTION 4: Cable Ladder & Aluminium Type 3/50 (NEMA 6A) Type 4/70L Type 5/112 (NEMA 20C) > 4:3 > 4:4 > 4:5 Aluminium Type 4/70A (NEMA 16B) Ladder Splice Plates > 4:7 > 3:18 Page 4:1 Cable Ladder General

More information

CT-02 CABLE TRAY SYSTEMS

CT-02 CABLE TRAY SYSTEMS CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry

More information

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia Exel Composites Cable Support Systems offer engineers a structural product for solving many design and plant engineering problems, enabling long term reliable support of expensive and often critical cables.

More information

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough Tray Bottom Types Ladder Extra wide aluminum rungs are welded to extruded aluminum I-beam siderails. Every second rung is reversed to allow for easy top or bottom mounting of cable ties and clamps. All

More information

Cable Support Solutions

Cable Support Solutions Cable Support Solutions B-Line by Eaton Technology Day Japan 2013 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved.

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

Flextray - Installation. Installation

Flextray - Installation. Installation 50 Flextray Cutters Part Qty./Box Wt./Box Number lbs. kg CLEANSHEAR Cleanshear 1 4.3 1.95 Cutting Tool Exclusive, patented Cleanshear cuts tray fast No sharp edges Designed specifically for cutting Flextray

More information

GLOBAL STANDARDS LOCAL EXCELLENCE

GLOBAL STANDARDS LOCAL EXCELLENCE GLOBAL STANDARDS LOCAL EXCELLENCE INDUSTRIAL CABLE LADDER CATALOGUE Light duty H = 50 mm, Medium duty H = 100 mm, Heavy duty H = 125 mm, Extra heavy duty H = 150 mm INDUSTRIAL CABLE LADDER CATALOGUE Introduction

More information

Session 14 Cable Support Systems

Session 14 Cable Support Systems Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load

More information

INSTALLATION. General. Important Note. Design. Transport

INSTALLATION. General. Important Note. Design. Transport General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No.

More information

CABLE TRAY. Introduction

CABLE TRAY. Introduction Introduction BLE TRAY ICMS cable tray system including Fittings and accessories is manufactured with return flange in a standard length of 2.44Mtr, according to the following specifications and standards:

More information

SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but

More information

Series 1 Steel Cable Ladder

Series 1 Steel Cable Ladder able Straight Sections See pages LDS-3 & LDS-4 Straight Section overs See page LDS-10 ccessories See pages LDS-5 - LDS-9 Fittings See pages LDS-11 - LDS-17 Fitting overs See page LDS-10 LDS-1 able Support

More information

EMI/RFI Shielded Cable Tray

EMI/RFI Shielded Cable Tray EMI/RFI Cable Tray Chalfant began supplying industry cable tray in 1948 and designed and developed the first RF Tray for NS in 196 when it became imperative to protect instrument and control cabling from

More information

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER Page 1 of 6 FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER 0 Issued for Review & Comments Rev. Date Description Eng. A.H Prepared by Checked by Approved by Page 2 of 6 REVISION CONTROL SHEET REV. NO. DATE

More information

This attractive cover system has been designed to complement the Pipe Cover and Skirting Cover product ranges.

This attractive cover system has been designed to complement the Pipe Cover and Skirting Cover product ranges. Box Cover This attractive cover system has been designed to complement the Pipe Cover and Skirting Cover product ranges. Talon Box Cover profile is offered in a range of sizes and is ideal in situations

More information

The RIGHT SOLUTIONS for Canada s Oil and Gas Industry. T&B Cable Tray Systems

The RIGHT SOLUTIONS for Canada s Oil and Gas Industry. T&B Cable Tray Systems The RIGHT SOLUTIONS for Canada s Oil and Gas Industry T&B Cable Tray Systems What if you could get all the right solutions from one reliable Canadian source? Engineers, contractors and end-users working

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

Best Practice Guide to Cable Ladder and Cable Tray Systems

Best Practice Guide to Cable Ladder and Cable Tray Systems Best Practice Guide to Cable Ladder and Cable Tray Systems Channel Support Systems and other Associated Supports November 2012 BEAMA Best Practice Guide to Cable Ladder and Cable Tray Systems Including

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

Cable Runways & Accessories

Cable Runways & Accessories SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

Dock Hardware & Accessory Products Catalog

Dock Hardware & Accessory Products Catalog Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set

More information

Stainless steel cable fixing solutions for critical environments

Stainless steel cable fixing solutions for critical environments Stainless steel cable fixing solutions for critical environments BAND-IT-IDEX is the world s leading manufacturer in quality clamping and banding systems. Since its inception in 1937, BAND-IT bands and

More information

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow

More information

Marine Type Cable Support Systems

Marine Type Cable Support Systems Material options: Stainless steel ISI 304 () (2) / ISI 316 () (4), S-37-42 Mild Steel, Corten, Pregalvanized steel, luminum Finish options : Hot ip Galvanized to 1461, Electrogalvanized to S 149, Electrostatic

More information

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200

More information

Cable Trays Technical Instructions & Specifications

Cable Trays Technical Instructions & Specifications Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased

More information

Cable/Conduit Conversion

Cable/Conduit Conversion Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits

More information

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.

More information

CABLE SUPPORT SYSTEMS

CABLE SUPPORT SYSTEMS CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder

More information

NEMA Standards Publication VE 2-2000. Cable Tray Installation Guidelines

NEMA Standards Publication VE 2-2000. Cable Tray Installation Guidelines NEMA Standards Publication VE 2-2000 Cable Tray Installation Guidelines Published by: National Electrical Manufacturers Association 1300 North 17th Street Rosslyn, VA 22209 Approved by: Cable Tray Institute

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

XL PREMIUM OIL COOLER KIT

XL PREMIUM OIL COOLER KIT -J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English

More information

Preformed Metal Roofing and Siding

Preformed Metal Roofing and Siding Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision

More information

Colonnade Security Pipe

Colonnade Security Pipe Description: Round & Square downpipe formed from extruded 6060 T4 aluminium in various sizes (Ø83mm, Ø108mm, 83x83 mm & 108x108mm*) & supplied with a complete range of accessories i.e. Offsets, bends,

More information

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

PRO PANELS. 1-800-525-4159 www.propanels.com. the artist s choice in display designed by artists, for artists. voice: 214-350-5765 fax: 214-350-7372

PRO PANELS. 1-800-525-4159 www.propanels.com. the artist s choice in display designed by artists, for artists. voice: 214-350-5765 fax: 214-350-7372 PRO PANELS by MD Enterprises the artist s choice in display designed by artists, for artists 1-800-525-4159 www.propanels.com voice: 214-350-5765 fax: 214-350-7372 MD Enterprises 1-800-525-4159 voice:

More information

GUARDRAIL INNOVATION FLOWS FROM HERE

GUARDRAIL INNOVATION FLOWS FROM HERE INNOVATION FLOWS FROM HERE ENSURING SAFETY ON CANADIAN HIGHWAYS The economics, versatility, and performance of Guardrail surpass all other roadside barrier systems. Guardrail provides highly-visible protection

More information

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET

More information

Embedded Parts Introduction - Anchors

Embedded Parts Introduction - Anchors In the plant construction or process plants such as chemical, petrochemical, gas or power plants various disciplines are brought into contact and built on each other. Civil, mechanical, electro technical

More information

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Isover ULTIMATE TM Protect - Fire protection

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

Safely Installing, Maintaining and Inspecting Cable Trays

Safely Installing, Maintaining and Inspecting Cable Trays Purpose U.S. Department of Labor Occupational Safety and Health Administration Directorate of Technical Support & Emergency Management Office of Technical Programs and Coordination Activities Safely Installing,

More information

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

Power Cube Open Source Ecology Page 1. Power Cube. Version 4 Power Cube Open Source Ecology Page 1 Power Cube Version 4 Power Cube Open Source Ecology Page 2 Contents Table of Contents Power Cube... 1 Contents...2 Introduction... 3 Bill Of Materials...4 Discrete

More information

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa Profiles in stock Standard catalogue Discover the possibilities with aluminium from Sapa You can create your own profile or you can choose from a wide selection of standard. Delivery: 1 2 weeks for standard

More information

R310EN 2225 (2011.04) The Drive & Control Company

R310EN 2225 (2011.04) The Drive & Control Company Ball Rail Systems Resist NRII R310EN 5 (011.04) he Drive & Control Company R310EN 5 (011.04) Ball Rail Systems Resist NR II Bosch Rexroth AG 3 Ball Rail Systems Resist NRII General Product Description

More information

SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS

SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications

More information

PW Cable Tray Ladder, Trough & Solid Bottom

PW Cable Tray Ladder, Trough & Solid Bottom PW Cable ray adder, rough & Solid Bottom Metallic Covers & Cover Connectors Covers protect and contain cables. hey are highly recommended to avoid damage to the tray contents and to protect against the

More information

Uncovered Decks & Porches

Uncovered Decks & Porches Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed

More information

Installation Guide 2010 BMW S1000RR Full Exhaust System

Installation Guide 2010 BMW S1000RR Full Exhaust System Installation Guide 2010 BMW S1000RR Full Exhaust System!! THIS PRODUCT IS DESIGNED FOR USE IN CLOSED COURSE RACING AND IS NOT INTENDED FOR HIGHWAY USE!! Congratulations on the purchase of your new TaylorMade

More information

MGB Chrome Bumper Conversion

MGB Chrome Bumper Conversion MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different

More information

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to

More information

Comparative study for cables and busbars

Comparative study for cables and busbars Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary

More information

270526-TC Grounding and Bonding for Telecommunications Systems

270526-TC Grounding and Bonding for Telecommunications Systems 270526-TC Grounding and Bonding for Telecommunications Systems Part 1 - General Related Documents The following related sections of the OT standards shall also be applicable to this section. OT Engineer

More information

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig. 7.21 some of the trusses that are used in steel bridges

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig. 7.21 some of the trusses that are used in steel bridges 7.7 Truss bridges Fig. 7.21 some of the trusses that are used in steel bridges Truss Girders, lattice girders or open web girders are efficient and economical structural systems, since the members experience

More information

Specialist Fixings. Your first fix experts

Specialist Fixings. Your first fix experts Specialist Fixings Your first fix experts Giving you what you want, when you want it... At Newey & Eyre, we are committed to provide you with all the product support you ll need. Whatever your requirement

More information

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC.

AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY. (The following code explanations are to be used with a copy of the 2011 NEC. AN IN-DEPTH LOOK AT 2011 NEC ARTICLE 392 - CABLE TRAY (The following code explanations are to be used with a copy of the 2011 NEC.) To obtain a copy of the NEC contact: National Fire Protection Association

More information

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Whitepaper Modular Substation Cable Termination Design Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Abstract The methods for cable penetrations into modular industrial substations are

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

STB Series Enclosures

STB Series Enclosures STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard

More information

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS TABLE OF CONTENTS I. RULES AND REGULATIONS A. TABLE OF CONTENTS... 2 B. TERMS AND DEFINITIONS... 3 C. DEVELOPER S/CONTRACTOR S RESPONSIBILITIES...

More information

NATIONAL INSTITUTE OF BIOLOGICALS

NATIONAL INSTITUTE OF BIOLOGICALS Short Term Notice Inviting Quotations Quotations No. S.1-36/07/NIB/Engg. (Civil) Invitation to short term quotations for Repairing of damaged gypsum board false ceiling and painting with epoxy paint in

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

Timber Decks. Technical Note. March 2007

Timber Decks. Technical Note. March 2007 Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.

More information

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard

More information

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping. BOQ SPECIFICATIONS VERTICAL BLINDS Vertical Blinds made of glass fibre fabrics in width 5 (or 4 ). Minimum overlapping of ¾ in fabric. Top aluminium anodized rail of 1.4 mm thickness. 2 inch wide channel

More information

Cable drag chain, type MP 41.2

Cable drag chain, type MP 41.2 2 nd Generation Damaskus Maskinskydd AB Anläggarvägen 2 SE-136 44 Handen SWEDEN Phn: +46 (0)8 556 505 20 www.damaskus.se Properties and application areas The MP 41.2 of the PowerLine series is a plastic

More information

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers.. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 04, Issue 01 (January. 2014), V6 PP 01-12 www.iosrjen.org Paper on Basbar Trunking System for Electrical Supply to Industrial

More information

Safety Grating GSSG-13R GRIP STRUT. safety grating

Safety Grating GSSG-13R GRIP STRUT. safety grating Safety Grating GSSG-13R safety grating Table of Contents & Advantages Advantages.................................................... 2 Proof Of Performance...................................... 3 General

More information

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume)

Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume) Code No. LIT-1921710 Issued July 25, 2011 T-4000 Series Accessories Selection Chart T-4000 Series Accessories (Part 1 of 5) ( or Volume) F-100-20 F-300-30 F-300-34 F-300-31 F-300-35 F-500-45 F-300-30 Coupler,

More information

Cable Tray Straight Sections Pages 5-11. Fittings Pages 10-17. Inside Vertical Bends. 90 Page 1-12 60 Page 1-13 45 Page 1-14 30 Page 1-15

Cable Tray Straight Sections Pages 5-11. Fittings Pages 10-17. Inside Vertical Bends. 90 Page 1-12 60 Page 1-13 45 Page 1-14 30 Page 1-15 Tray When metal ladder cable trays came of age, they were used to support the new armored shielded power cables that were permitted outside the conduit environment. Utilities and industrial companies initiated

More information

Heating Cable. Construction

Heating Cable. Construction Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

BIS Metal Pipe Clamps with Lining

BIS Metal Pipe Clamps with Lining A BIS Metal Pipe Clamps with Lining BIS Clamps BISMAT Flash BISMAT 2000 Ø ¼ - 2" BISMAT 2000 Ø 2½ - 4" 2 3 4 BIS Industrial Clamps BIS Heavy Duty Clamps HD1501 (1/2") (BUP1000) 5 BIS Clamps for Plastic

More information

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems. Breezway Altair Powerlouvre Window 35 Breezway Altair Powerlouvre Window The Powerlourve Window motor is neatly concealed within the Easyscreen TM Frame or the Component Powerlouvre Head Section. Automated

More information

Scepter PVC Molded Junction Boxes

Scepter PVC Molded Junction Boxes Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW

More information

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique EXTeR US G L A S S - With patented design, able to join technology and quality of materials with a charming shape. Unique thanks to its outstanding loading capability with 150 kg maximum weight and height

More information

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529) Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

Ladder. Ladder Style Cable Tray. Typical Installations. Chalfant Cable Trays

Ladder. Ladder Style Cable Tray. Typical Installations. Chalfant Cable Trays Style Cable Tray Typical Installations Chalfant Cable Trays Tray When metal ladder cable trays came of age, they were used to support the new armored shielded power cables that were permitted outside the

More information

PVC-U Domestic and general trunking

PVC-U Domestic and general trunking PVC-U Domestic and general trunking w w w. m a r s h a l l - t u f f l e x. c o m A range of cost-effective PVC-U cable containment for domestic and general wiring installations. 146 Introduction PVC-U

More information

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number Fiber Optic Cleaver D6 For Single- and Multimode Fibers Diamond blade for highest cleave quality and long life (typically > 10,000 cleaves) Fiber cleave length: 3.5 to 15 mm Fiber diameter: 125 µm nominal

More information

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1 C. S. I. Spec 03500 Page 1 PART 1 - GENERAL 1.01 SUMMARY:.01 Provide special glassfiber reinforced cement (GRC) shapes in accordance with the requirements of the contract documents..02 The installing contractor

More information

Stainless steel grade chart

Stainless steel grade chart Stainless steel grade chart ATLAS STEELS METAL DISTRIBUTION Chemical analysis (%) specified C Si Mn P S Cr Mo Ni Other Austenitic stainless steels 253MA S30815 0.05 1.1-2.0 0.8 0.040 0.030 20.0-22.0 10.0-12.0

More information

HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING

HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING ENGINEERING LTD. HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING Member of PF Group Guardrail Engineering Limited Manders Industrial Estate Old Heath Road Wolverhampton

More information

SSG PRODUCTS FOR SHIPS AND OFFSHORE

SSG PRODUCTS FOR SHIPS AND OFFSHORE 6.1 SSG PRODUCTS FOR SHIPS AND OFFSHORE SSG workshop cabinets, tables and shelving system specially adapted to be used on-board ships and offshore. Developed in close cooperation with users from these

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS

San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by

More information

LHD LINEAR HEAT D ETECTIONN

LHD LINEAR HEAT D ETECTIONN Tri-Metallic Core: Steel provides tensile strength Copper increase conductivity Tin for corrosion resistance LHD LINEAR HEAT D ETECTIONN TECHNICAL DATA Temperature Rating: 155 F (68 C) (typical temperature)

More information

RAIL FREE SOLAR ROOF MOUNT

RAIL FREE SOLAR ROOF MOUNT RAIL FREE SOLAR ROOF MOUNT Utilizes EcoFasten Solar s patented technology Rock-it system Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are the easiest

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers SnapStak Hangers New design increases stack height SnapStak hangers have become the industry standard for maximizing space utilization on crowded towers and now that utility is further expanded with the

More information