THE SOFTWARE PRODUCTS FOR WATER NETWORKS MANAGEMENT THE CONTROL TECHNOLOGY GROUP. The AQUASOFT family solutions allow to perform:

Size: px
Start display at page:

Download "THE SOFTWARE PRODUCTS FOR WATER NETWORKS MANAGEMENT THE CONTROL TECHNOLOGY GROUP. The AQUASOFT family solutions allow to perform:"

Transcription

1 THE SOFTWARE PRODUCTS FOR WATER NETWORKS MANAGEMENT FAST SpA introduces the AQUASOFT family applications, dedicated to water networks complete supervision. The products are essential for unified management of the entire cycle of water thanks to an articulated and detailed knowledge of the sector. The Fast wide proposal consists of several software packages specially designed and realized to perform specific tasks of water networks management. Besides the software packages integrate in a simple and functional manner to the different RTU belonging to the AQUALOG family. The AQUASOFT family solutions allow to perform: Networks local and remote supervision Water supply efficiency evaluation Leak detection Pressures, flows and tank levels control Management of pumping station Coordination of geographically distributed equipment Management of service and maintenance Water Hammer investigation Integration of communications and databases from other vendors THE CONTROL TECHNOLOGY GROUP

2 The possibility to check, monitor and supervise remotely the technological installations using standard communications vectors and networks allows the optimization of systems performance, the improvement of their efficiency and safety and the reduction of the operational costs drastically. The constant access to the most innovative technologies allows to reformulate the TELEMANAGEMENT concept which, from product oriented, becomes company oriented, granting wide flexibility, availability and huge opening towards existing systems. The products of the AQUASOFT family deliver technology services closely related to the management of water resources. The field s data collected using RTU, stored and analysed through AQUASOFT products form an unitary knowledge platform shared by the company s different subjects, either if they are operative or managing departments or decentralized locations, which can use the information and the system in general, in efficient and effective manner. AQUASOFT Family: the software products for water networks management AQUAWORKS PLANT VIEW OVERLAND SCADA SYSTEM OVERLAND ADVANCED ALARM MESSENGER SERVER MAINTENANCE COMMUNICATION LAYER Application software specialized in the leak detection and pressure control. Supervision software for water networks and systems connected. Usable with any HMI device connected to Internet. Software for water networks monitoring based on WEB technologies. Usable by any terminal connected to Internet. Virtual Call center for the management of the 24-hour technical service and maintenance. Equipment maintenance managing system. Software for managing communications and databases. Able to operate with devices and software from other vendors. FAST SpA - Via Talete, 2/ Rubiera (RE) ITALY Tel. (+39) Fax (+39) info@fastautomation.it

3 AQUAWORKS The instrument for leakage detection and pressure control ACTIVE PRESSURE MANAGEMENT AQUAWORKS is a specialized software that assists the operator to immediately capture the most important events in water network: from the DMAs creation to the leak detection. Using the operator language it helps to evaluate the network efficiency and to practice a leakage management more effective. The PMZ management becomes particularly effective and the manager can verify network performance using real data and IWA indicators. AQUAWORKS is a powerful analysis tool able to identify and capture every critical event by presenting it clearly to the management service. Even in very extended and complex networks, the manager can evaluate in real-time the network efficiency, estimating the leakage, monitoring pressure values and performing any intervention / maintenance / configuration action at the right time. DMAS ORGANIZATION The districts are topologically identified and organized through the water balance calculated thanks to the values taken from the instrumentation and from statistical and theoretical assessments. Each district is characterized by the data acquired from aqueduct, users and instrumentation applied. FUNCTIONS Graphical analysis show the trend of flows and pressures with special reference to nocturnal behaviors Comparisons between different periods in the same district or different districts Loss estimation in accordance with IWA indicators Evaluation of fault repair and operation recovery effects Evaluation of improvement convenience Efficiency evaluation and reporting Alarm in case of exceeding thresholds Pressure transient notification THE CONTROL TECHNOLOGY GROUP

4 AQUAWORKS The AQUAWORKS software main functions are: DISTRICTS MANAGEMENT Each district is associated to its own detection instruments set installed (also temporarily) in order to be able to evaluate the leakage, making easier their calculation both by methods provided by the Italian legislation (decree 99/97) and those developed by the technicians of IWA Water Losses Specialist Group, the world association born on a problem known everywhere: the water leaks. VARIABLES CALCULATED ELABORATION The trace is the sequence of values corresponding to a variable. The traces can be natural, that is reflecting exactly the variable in field, or calculated (variables linked by arithmetic operations, derived, minimal, maximal, medium), flow derivations from a tank level s trend. TRACES VISUALIZATION BY ADVANCED GRAPHIC FUNCTIONS A powerful graphic display shows the trend of the variables, aggregated according to the customer needs. This function supplies a clear image of the situation and its evolution. Each trace is supported by a line of statistics enclosing: minimum, maximum, medium, volumes integration (in case of FLOWS). STATISTIC TRACES VISUALIZATION data representation s interval variation starting from 5 min. up to 24 hours: corresponding to the data average within the 24 hours corresponding to the minimum within the 24 hours corresponding to the maximum within the 24 hours related to the time interval selected, i.e. minimum from to representation scale variation, i.e. from l/s up to m3/hour, from bar to m.c.a. TARGET SETTING In order to give objectivity to the information recorded, the traces are compared with target lines corresponding to the minimum and maximum dispersion level in each district. IDENTIFICATION AND REPORTING OF LEAKAGE Based on the investigation strategy, generally deviation or remarkable discontinuities, reports of such interceptions are provided. The reports are graphic type or as alarm message transmitted via e- mail or SMS. EVALUATION OF INTERVENTIONS At last it is possible to evaluate the actual effectiveness of any localization and repair intervention and the recovery of dispersed volumes. FAST SpA - Via Talete, 2/ Rubiera (RE) ITALY Tel. (+39) Fax (+39) info@fastautomation.it

5 PLANT VIEW OVERLAND Technological Areas General Management WEB Supervision Maintenance Teams THE SCADA SYSTEM FOR TERRITORY TELEMANAGEMENT Plant View Overland is the SCADA (Supervisory, Control and Data Acquisition) graphic package wholly realized by Fast, specialized for the technological networks remote management. Thanks to Plant View Overland the issues related to on territory distribution of several operational sites, equipped with RTU dedicated to different tasks, linked by the most different transmission and different communication protocols systems, are solved in a transparent and unitary operative platform able to standardize all the information to great benefit of the manager. Plant View Overland is a Company-Oriented SCADA, that means designed for considering the needs of a company submitted to the management of distribution networks of utilities. The different Company departments find a common support to perform at the best their own duties in a synergetic and rewarding context. Regardless of the transmission means used, any information contributes to form a knowledge unitary and shared platform in order that the different company subjects, either if they are operative or managing departments or decentralized locations, can use the information and the system in general, in efficient and effective manner. THE CONTROL TECHNOLOGY GROUP

6 PLANT VIEW OVERLAND The Company Departments to which is devoted the Plant View Overland attention are: Operations Room The persons in charge of the operations room keep the whole company plant site under control using monitors and wide range synoptic panels. Their duty is strongly facilitated by video synoptics reporting overall and detailed situations, where the anomalies onset is clearly reported and diagnosed. All the remote control standard functions are available in an easy and effective manner. Maintenance and 24 hour-repair Service Teams management Mobile devices in use by the maintenance teams were joined by the communication services discharging diagnostic messages about the status of the plants. Any emergencies are promptly reported and dealt with, ensuring a lean and efficient service to the end user. Thanks to the Web connections operable from any PC equipped with Internet Explorer, the maintenance teams have all the information needed to perform their activities in shared mode with the control center. Technological Areas The plant trend database forms a precious knowledge consolidation support for the company technologists. The information can be consulted in a simple and practical manner by the most popular market instruments. The distribution networks higher analysis capability and study forms the fundamental lever to improve the systems technological management and for the industrial asset maintenance. From this derive applications for networks mapping, networks modelling help, energy saving studies, maintenance, asset life cycle extension, etc. Company Management The system stores the operational data on database, whose content is made available to the General Management. Using simple common instruments, the GM obtains important information, in order to estimate the efficiency level and to evaluate economic, managing and administrative factors. This availability becomes a particularly useful instrument for the evaluation of the company assets and for the planning of future investments. FUNCTIONAL FEATURES: Multi-media communication The system transmits with all the communication standard: TCP/IP, ADSL, Wi-Fi, GPRS, GSM, PSTN, Radio, etc. Communication protocols wide availability There is a wide range of communication protocols available for the devices of the most important players in the sector. Fast develops also protocols upon customer s requirement. Web Interoperability Thanks to the Web Client function the information are distributed via Web. On duty staff management The system forecasts an advanced management for on duty staff call, with possibility of sending SMS and/or voice messages. Integrability with existing systems Thanks to the standard OPC use the system integrates itself with other SCADA systems eventually present. Security Users and passwords management protects the system from unauthorised access. Reliability and Availability The system is fault tolerant thanks to the redundancy management with hot-backup. Scaling It is possible to start from a small size architecture and then expand in following steps the system s implementation. Engineering oriented towards the distributed installations The peripherals configuration and their integration uses an advanced model methodology based on an internal automation high level. FAST SpA - Via Talete, 2/ Rubiera (RE) ITALY Tel. (+39) Fax (+39) info@fastautomation.it COMMUNICATION CLOUD

7 OVERLAND ADVANCED MONITORING VIA WEB OF THE WATER NETWORK Overland Advanced is the web-based software package designed to monitor the water network. The system collects the data acquired by the Data Loggers geographically distributed, saves them to a database located in a management center and displays them via web pages. FUNCTIONS Integration into GIS system Management of all plants in the distribution network by dividing it into zones. Monitoring of data, such as pressure input and output, and reporting of all abnormal situations and plant alarms for every system. View the data collected by the RTUs in tabular form or by trends. You can also download the data to your PC for further processing through spreadsheets. The system manages the alarm signaling to the staff responsible by sending /sms or voice calls, in order to allow the quick and decisive action on the system in alarm. This is possibile thanks to Fast Alarm Messenger Server application. THE CONTROL TECHNOLOGY GROUP

8 OVERLAND ADVANCED ARCHITECTURE The hardware and software system includes: The geographic distribution of remote control devices Data Logger dedicated to the acquisition of the necessary data to monitor plant The software modules necessary for the management of remote devices A central database for data recording (the database can be installed on a server of the Client or End User, or managed directly by Fast hosting service) A Web Server portal resides on the site of the user interface application (in this case, the support can be provided by Fast hosting service) The user interface software in WEB mode The WEB interface software allows the user to access data everywhere, just to have an Internet connection, without the need to install additional software on the PC. Alarm Management Assistance & Maintenance Users Data Servers GLOBAL NETWORK FAST SpA - Via Talete, 2/ Rubiera (RE) ITALY Tel. (+39) Fax (+39) info@fastautomation.it

9 FAST ALARM MESSENGER SERVER ALARM Operators and maintenance men TO WHOM Voice calls FAST ALARM MESSENGER SERVER HOW SMS ALARM REPORTING BY SENDING MESSAGES Messenger Server is the software package designed and developed by Fast for reporting promptly the occurrence of an alarm condition to one or more operators. The program provides: a configuration section where it is possible to set, for each signal coming from the field, the parameters and logics according to which the datum must activate an alarm (available also a scripting language for complex logics); an application section which elaborates in real time the data coming from the field and, if the conditions are met for an alarm activation, it proceeds to deliver the signalling to the operators involved. The message fundamental typologies managed are: Voice calls SMS sending sending The signals activating the alarm/event come from external control devices both local (like PLC, terminals, computerized systems) and remote (like RTU, remotely controlled measurements instruments) and they are acquired through the use of communication drivers based on the OPC protocol. This world standard allows to connect and use systems of different manufacturers in a transparent and open manner. THE CONTROL TECHNOLOGY GROUP

10 FAST ALARM MESSENGER SERVER The message delivery to the operator can be configurated considering an availability calendar and subdividing the alarms/events into a belonging group. In this way the reporting management is optimized granting an immediate and effective answer, even maintaining the messages transmission centralization also in wide dimensions plants and/or geographically distributed. <STAZIONE><DATA/ORA><DESCRIZIONE ALLARME> Based on the alarm seriousness it is possible to request the operator to confirm the message reception. In case the operator has no way to do so, the system will provide to send the signalling to another operator, until when a designated person will take care it interrupting the calls sequence. If the system is attended it is possible to produce a video document (.doc,.pdf) and to ring the PC speaker together with the alarm. All the communications are stored on database in order to produce detailed reports which can be visualized also through WEB pages. Functional features: Acquisition of alarm/alert signals coming from remote plants through SMS, data call, or anything else Acquisition of field signals reading through OPC industrial protocol Complex logics creation (by programming language) to determine an alarm activation Reporting by different messages typologies (voice calls, SMS, ) also at the same time Transparent managing of several communication devices with the chance to limit the resources for alarm group Involved operators configuration with different priority levels and based on availability calendar Possibility to request the operator (based on the type of message and its importance) an answer to communicate the signalling handling WEB reporting FAST SpA - Via Talete, 2/ Rubiera (RE) ITALY Tel. (+39) Fax (+39) info@fastautomation.it

11 MAINTENANCE FOR MAINTENANCE MANAGEMENT AND CONTROL Maintenance is the software package for the maintenance managing of instruments, machines and equipment installed in a large territory. It focuses on the activities of the main critical equipment to program properly the preventive maintenance operations. The package allows to: define the layout of the installations geographically distributed, such as plant s datasheet; for each plant s datasheet, define the parts or components which require preventive maintenance; acquire from field the information regarding the equipment activity to update the maintenance program; get an overview of the entire park installed under the maintenance aspect; historicize the maintenance operations performed; visualize informative documents (layouts, manuals) regarding the specific parts. THE CONTROL TECHNOLOGY GROUP

12 MAINTENANCE Configuration Tool it allows to represent schematically the plant and, for each critical component, to plan the preventive maintenance operations needed for the plant s good functioning. Plant Manager it allows to keep under control the plant status, the maintenance operations already performed, the maintenance operations to be performed. FAST SpA - Via Talete, 2/ Rubiera (RE) ITALY Tel. (+39) Fax (+39) info@fastautomation.it

13 COMMUNICATION LAYER HMI SCADA Applications GLOBAL NETWORK Communication Layer Communication lines Telephone line, SMS, GPRS, TCP/IP, Radio Other vendor databases System database FOR MANAGING COMMUNICATIONS AND DATABASES Communication Layer is an advanced communication driver characterized by a wide configurability and a highest interoperability. Using standard communication interfaces it manages the communication both to the field, by connecting a wide range of RTU, both to the supervision center, by interfacing to different SCADA systems and to multiple SQL databases. Communication Layer works with the abstract concepts of RTU and CommDevice: its functionality is indipendent from the hardware model of remote devices or from the type of communication equipment used in the supervision and remote control system. The features are: continuous-time connectivity ( always on line ) or discrete-time ( dial-up ) of the supervision software from and to the remote devices acquisition of remote plant's status and trends of the variables that measure its functioning acquisition of alarm events sent spontaneously or historicized by the device sending remote commands or modifying device operating parameters acquisition data from other vendor databases THE CONTROL TECHNOLOGY GROUP

14 COMMUNICATION LAYER The peculiar combinations of RTU (especially their data protocol) and CommDevice in the system help to determine the specific "Communication Layer", i.e. all the moods and tenses with which communication occurs between the control center and the periphery: Continuous connection started from the center Continuous connection started from the periphery Dial-up connection started from center on operator request Dial-up connection started from center on cyclic scheduling ( ronda ) Dial-up connection started from periphery FAST SpA - Via Talete, 2/ Rubiera (RE) ITALY Tel. (+39) Fax (+39) info@fastautomation.it

AutoLog ControlMan. Remote Monitoring & Controlling Service

AutoLog ControlMan. Remote Monitoring & Controlling Service AutoLog 1 AutoLog ControlMan Remote Monitoring & Controlling Service Web browser based HMI / SCADA interface Server is hosted by Internet server hosting company Control units communicate wirelessly via

More information

HMS Industrial Networks

HMS Industrial Networks HMS Industrial Networks Putting industrial applications on the cloud Whitepaper Best practices for managing and controlling industrial equipment remotely. HMS Industrial Networks AB Stationsgatan 37 30245

More information

HMS Industrial Networks. Putting industrial applications on the cloud

HMS Industrial Networks. Putting industrial applications on the cloud HMS Industrial Networks Putting industrial applications on the cloud Whitepaper Best practices for managing and controlling industrial equipment remotely. HMS Industrial Networks Inc 35 E Wacker Drive,

More information

EDL-Portal. Energiedienstleistung

EDL-Portal. Energiedienstleistung Energiedienstleistung EDL-Portal EDL-Portal 2.0 Energiedienstleistung EDL stands for energy services (EnergieDienstLeistung). The EDL internet portal, www.edl.ch, provides a user-friendly platform for

More information

Monitoring & Control of Small-scale Renewable Energy Sources

Monitoring & Control of Small-scale Renewable Energy Sources Small Scale Renewable Energy Sources and Energy Saving: 6-17 th July 2009 Monitoring & Control of Small-scale Renewable Energy Sources Dr G A Taylor Brunel Institute of Power Systems Brunel University,

More information

Semaphore T BOX Applications in Data Center Facilities

Semaphore T BOX Applications in Data Center Facilities Semaphore T BOX Applications in Data Center Facilities Introduction Data centers must reliably provide 24/7/365 operation. For automation and monitoring of the facility, use of a rugged, reliable RTU is

More information

Introduction To SCADA and Telemetry

Introduction To SCADA and Telemetry Introduction To SCADA and Telemetry Joe Mullaney Senior I&C Engineer MSE Technology Applications, Inc. Tetragenics Division joe.mullaney@mse-ta.com Overview Definitions What is SCADA? What is Telemetry?

More information

Efficient remote access to machines and plants with SIMATIC

Efficient remote access to machines and plants with SIMATIC Efficient remote access to machines and plants with SIMATIC Telecontrol and teleservice solutions modular, flexible and secure SIMATIC NET siemens.com/industrial-remote-access Industrial remote access

More information

PROFINET IO Diagnostics 1

PROFINET IO Diagnostics 1 PROFINET IO is a very cost effective and reliable technology. However, extensive installations can have thousands of PROFINET IO devices operating on many networks. The reliable operation of these networks

More information

Off-the-shelf Packaged Software Systems And Custom Software Analysis By Gamal Balady MASS Group, Inc.

Off-the-shelf Packaged Software Systems And Custom Software Analysis By Gamal Balady MASS Group, Inc. Off-the-shelf Packaged Software Systems And Custom Software Analysis By Gamal Balady MASS Group, Inc. April 1, 2004 1 Presentation Overview I. Packaged Software Systems vs. Custom Software Systems II.

More information

CONTROL LEVEL NETWORK RESILIENCY USING RING TOPOLOGIES. Joseph C. Lee, Product Manager Jessica Forguites, Product Specialist

CONTROL LEVEL NETWORK RESILIENCY USING RING TOPOLOGIES. Joseph C. Lee, Product Manager Jessica Forguites, Product Specialist CONTROL LEVEL NETWORK RESILIENCY Written by: Joseph C. Lee, Product Manager Jessica Forguites, Product Specialist DANGER 65 65 65 65 65 65 65 65 EtherNet/IP 1 3 4 5 6 LINK 1 LINK MOD NET 15 14 13 1 11

More information

NETWORK MONITORING. Network Monitoring. Product brief. NETWORK MONITORING Logger Only

NETWORK MONITORING. Network Monitoring. Product brief. NETWORK MONITORING Logger Only Network Monitoring 1 Network Monitoring Product brief Logger Only CONTENTS 1 Page 1. Introduction 2-3 2. Network Structure 4 3. Data Collection 5 4. Data Visualisation 6 5. Dashboard 7 6. Alarm Management

More information

Radiological Assessment Display and Control System

Radiological Assessment Display and Control System Features Fast, real-time data acquisition and control Highly reliable communication with remote terminal units Collecting, converting, integrating and analyzing data from all monitors Detecting, annunciating

More information

PLCs and SCADA Systems

PLCs and SCADA Systems Hands-On Programmable Logic Controllers and Supervisory Control / Data Acquisition Course Description This extensive course covers the essentials of SCADA and PLC systems, which are often used in close

More information

Water Services Corporation SCADA A Tool for Efficient Resource Management

Water Services Corporation SCADA A Tool for Efficient Resource Management Water Services Corporation SCADA A Tool for Efficient Resource Management The experience of Water Service Corporation Malta for the Water/WasteWater Management Systems Ing. Antoine Psaila Sig. Corrado

More information

Alert ALARM MANAGEMENT

Alert ALARM MANAGEMENT by Alert ALARM MANAGEMENT Alert To inform and to alert Alert is able to treat alarms or intervention demand coming from different sources: Supervisor software (SCADA), via DDE, OPC or dedicated interface

More information

CNG IN A BOX: Cloud Based Enterprise Historian w\dash Boarding Solution for CNG Fueling Stations

CNG IN A BOX: Cloud Based Enterprise Historian w\dash Boarding Solution for CNG Fueling Stations CNG IN A BOX: Cloud Based Enterprise Historian w\dash Boarding Solution for CNG Fueling Stations Project: CNG in a BOX: Cloud Based Enterprise Historian w\dash boarding for CNG Fueling Stations. 1. INTRODUCTION

More information

Kepware Whitepaper. Enabling Big Data Benefits in Upstream Systems. Steve Sponseller, Business Director, Oil & Gas. Introduction

Kepware Whitepaper. Enabling Big Data Benefits in Upstream Systems. Steve Sponseller, Business Director, Oil & Gas. Introduction Kepware Whitepaper Enabling Big Data Benefits in Upstream Systems Steve Sponseller, Business Director, Oil & Gas Introduction In the Oil & Gas Industry, shifting prices mean shifting priorities. With oil

More information

KPI, OEE AND DOWNTIME ANALYTICS. An ICONICS Whitepaper

KPI, OEE AND DOWNTIME ANALYTICS. An ICONICS Whitepaper 2010 KPI, OEE AND DOWNTIME ANALYTICS An ICONICS Whitepaper CONTENTS 1 ABOUT THIS DOCUMENT 1 1.1 SCOPE OF THE DOCUMENT... 1 2 INTRODUCTION 2 2.1 ICONICS TOOLS PROVIDE DOWNTIME ANALYTICS... 2 3 DETERMINING

More information

Improving city infrastructure resilience capacity: water-supply network case study

Improving city infrastructure resilience capacity: water-supply network case study mproving city infrastructure resilience capacity: -supply network case study O. Jukić,. Heđi,. Špeh Virovitica College, Virovitica, Republic of Croatia {oliver.jukic ivan.hedi ivan.speh}@vsmti.hr Abstract

More information

DATAWORX32 V9.2 REDUNDANCY. An ICONICS Whitepaper

DATAWORX32 V9.2 REDUNDANCY. An ICONICS Whitepaper 2010 DATAWORX32 V9.2 REDUNDANCY An ICONICS Whitepaper CONTENTS 1 ABOUT THIS DOCUMENT 1 1.1 SCOPE OF THE DOCUMENT... 1 1.2 REVISION HISTORY... 1 1.3 DEFINITIONS... 1 2 DATAWORX 32 V9 REDUNDANCY 2 2.1 DATAWORX32

More information

Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)

Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System) Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System) Aye Min Zaw 1, Hla Myo Tun 2 Department of Electronic Engineering, Mandalay Technological

More information

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS The proposal shall be for supplying pre-wired cellular ready to install field

More information

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited (Rev. 1.0) China Aerospace Telecommunications Limited Contents 1. Introduction......3 2. Specifications...4 2.1 External Interface... 4 2.2 Status Indicator...... 5 2.3 Technical Parameters... 6 3. Device

More information

INTELLIGENT DISTRIBUTION NETWORK ANALYSIS AND INFORMATION ARCHITECTURE DESIGN

INTELLIGENT DISTRIBUTION NETWORK ANALYSIS AND INFORMATION ARCHITECTURE DESIGN INTELLIGENT DISTRIBUTION NETWORK ANALYSIS AND INFORMATION ARCHITECTURE DESIGN Yun CHEN SMEPC,State Grid China daddygirl@126.com ABSTRACT From the background of intelligent distribution network construction,

More information

SCADA Questions and Answers

SCADA Questions and Answers SCADA Questions and Answers By Dr. Jay Park SCADA System Evaluation Questions Revision 4, October 1, 2007 Table of Contents SCADA System Evaluation Questions... 1 Revision 4, October 1, 2007... 1 Architecture...

More information

Introduction to Network Management

Introduction to Network Management Introduction to Network Management Chu-Sing Yang Department of Electrical Engineering National Cheng Kung University Outline Introduction Network Management Requirement SNMP family OSI management function

More information

SPPA-T3000 Control System The Benchmark in Controls

SPPA-T3000 Control System The Benchmark in Controls Instrumentation, Controls & Electrical SPPA-T3000 Control System The Benchmark in Controls Siemens Power & Process Automation Answers for energy. The benchmark for Distributed Control Systems Developed

More information

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW I/A Series SOFTWARE Product Specifications Logo I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 The I/A Series Intelligent SCADA Platform takes the traditional SCADA Master Station to a new

More information

Solutions using our software products

Solutions using our software products SAE Automation, s.r.o. Nová Dubnica Solid And Effective partner at development of your products and industrial automation Solutions using our software products OpcDbGateway, SAEAUT SNMP OPC Server, SAEAUT

More information

A Proposed Integration of Hierarchical Mobile IP based Networks in SCADA Systems

A Proposed Integration of Hierarchical Mobile IP based Networks in SCADA Systems , pp. 49-56 http://dx.doi.org/10.14257/ijsh.2013.7.5.05 A Proposed Integration of Hierarchical Mobile IP based Networks in SCADA Systems Minkyu Choi 1 and Ronnie D. Caytiles 2 1 Security Engineering Research

More information

Dream Report vs MS SQL Reporting. 10 Key Advantages for Dream Report

Dream Report vs MS SQL Reporting. 10 Key Advantages for Dream Report Dream Report vs MS SQL Reporting 10 Key Advantages for Dream Report Page 2 of 15 Table of Contents INTRODUCTION 3 PROFESSIONAL SOFTWARE FOR NON-PROGRAMMING USERS 4 CONSIDERABLE DIFFERENCE IN ENGINEERING

More information

F454. Web Server. User Manual 05/12-01 PC

F454. Web Server. User Manual 05/12-01 PC F454 Web Server User Manual 05/2-0 PC 2 Web Server Contents Introduction and basic functions 5. Connection modes 6.. Connection to the data network 6..2 Remote connection 6.2 Using the Web Server with

More information

Having full access to real-time production data enables you to detect and anticipate weak spots in the production system and to make the right

Having full access to real-time production data enables you to detect and anticipate weak spots in the production system and to make the right Lean Manufacturing: Performance, OEE and Downtime Analysis 2 Having full access to real-time production data enables you to detect and anticipate weak spots in the production system and to make the right

More information

OpenControl. Utilization

OpenControl. Utilization Developed By Buraq Integrated Solutions www.buraq.com Funded By National ICT R&D Fund www.ictrdf.org.pk/ 1 Development of Open Source HMI HMI Human Machine Interface - HMI The Human Machine Interface is

More information

OPC COMMUNICATION IN REAL TIME

OPC COMMUNICATION IN REAL TIME OPC COMMUNICATION IN REAL TIME M. Mrosko, L. Mrafko Slovak University of Technology, Faculty of Electrical Engineering and Information Technology Ilkovičova 3, 812 19 Bratislava, Slovak Republic Abstract

More information

THEME Competence Matrix - Electrical Engineering/Electronics with Partial competences/ Learning outcomes

THEME Competence Matrix - Electrical Engineering/Electronics with Partial competences/ Learning outcomes COMPETENCE AREAS STEPS OF COMPETENCE DEVELOPMENT 1. Preparing, planning, mounting and installing electrical for buildings and industrial applications He/She is able to prepare and carry out simple electrical

More information

SHORT TRAINING COURSES

SHORT TRAINING COURSES Post Office Box SR 95, Spintex Road, Ghana Tel: +233 302 812680, Fax: +233 302 814709 E mail: contact@automationghana.com Website: www.automationghana.com SHORT TRAINING COURSES Equipping industries with

More information

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation Nokia E70 Configuring connection settings Nokia E70 Configuring connection settings Legal Notice Copyright Nokia 2006. All

More information

of The New England Water Works Association

of The New England Water Works Association Journal Our 132nd Year of The New England Water Works Association Volume 127 No. 2 June 2013 PUTNAM WATER TREATMENT PLANT AQUARION WATER COMPANY OF CONNECTICUT GREENWICH, CONNECTICUT New England Water

More information

SCADA AND SECURITY DISPATCHES ACCORDING TO PRESENT LEGISLATION IN ROMANIA

SCADA AND SECURITY DISPATCHES ACCORDING TO PRESENT LEGISLATION IN ROMANIA Cristian Silviu BANACU Bucharest University of Economic Studies Emilian Cristian IRIMESCU Bucharest University of Economic Studies SCADA AND SECURITY DISPATCHES ACCORDING TO PRESENT LEGISLATION IN ROMANIA

More information

CYBER SECURITY: SYSTEM SERVICES FOR THE SAFEGUARD OF DIGITAL SUBSTATION AUTOMATION SYSTEMS. Massimo Petrini (*), Emiliano Casale TERNA S.p.A.

CYBER SECURITY: SYSTEM SERVICES FOR THE SAFEGUARD OF DIGITAL SUBSTATION AUTOMATION SYSTEMS. Massimo Petrini (*), Emiliano Casale TERNA S.p.A. 21, rue d Artois, F-75008 PARIS D2-102 CIGRE 2012 http : //www.cigre.org CYBER SECURITY: SYSTEM SERVICES FOR THE SAFEGUARD OF DIGITAL SUBSTATION AUTOMATION SYSTEMS Massimo Petrini (*), Emiliano Casale

More information

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution System integration oriented data center planning In terms of ATEN's eco Sensors DCIM solution 1. Introduction The reliability of an enterprise data center servicing either external or internal clients

More information

Trains crossing at Toronto s Old Mill Station 2009 TTC. Train Control

Trains crossing at Toronto s Old Mill Station 2009 TTC. Train Control Trains crossing at Toronto s Old Mill Station 2009 TTC 76 An Advance Communication Based System for Toronto Resignaling for Higher Performance The Yonge-University-Spadina Line (YUS) in Toronto had been

More information

Reducing operating costs of power generators with cloud-based remote management

Reducing operating costs of power generators with cloud-based remote management Reducing operating costs of power generators with cloud-based remote management Whitepaper How remote management can be used to cut costs and improve maintenance. HMS Industrial Networks AB Stationsgatan

More information

Technical Training Module ( 30 Days)

Technical Training Module ( 30 Days) Annexure - I Technical Training Module ( 30 Days) Section 1 : Programmable Logic Controller (PLC) 1. Introduction to Programmable Logic Controller - A Brief History, Need and advantages of PLC, PLC configuration,

More information

Rosemount TankMaster So advanced that it s easy to use

Rosemount TankMaster So advanced that it s easy to use Rosemount TankMaster So advanced that it s easy to use The Emerson logo is a trademark and servicemark of Emerson Electric Co. Rosemount TankMaster is a trademark of Rosemount Tank Radar AB. IFIX is a

More information

Frédéric Tardieu, IBITEK Group, details the company s business intelligence tool and how it can be used to help decision-making from the plant up.

Frédéric Tardieu, IBITEK Group, details the company s business intelligence tool and how it can be used to help decision-making from the plant up. Frédéric Tardieu, IBITEK Group, details the company s business intelligence tool and how it can be used to help decision-making from the plant up. Introduction Information technologies have become an important

More information

SCADAvantage Network Topology System software products

SCADAvantage Network Topology System software products Data sheet DS/2101193-EN Rev. AD SCADAvantage Network Topology System software products Basic elements of a SCADAvantage system SCADAvantage has three distinct parts: the, the RTRDB, and the Client. Diagram

More information

How can I manage all automation software tasks in one engineering environment?

How can I manage all automation software tasks in one engineering environment? How can I manage all automation software tasks in one engineering environment? With Totally Integrated Automation Portal: One integrated engineering framework for all your automation tasks. Answers for

More information

METERS Data Collection CONTROL. Dialog3G. AMR/AMI Solutions

METERS Data Collection CONTROL. Dialog3G. AMR/AMI Solutions METERS Data Collection CONTROL Dialog3G AMR/AMI Solutions The Arad Group of affiliated companies and independent distributors around the world offers its customers a fully integrated source for a complete

More information

Movicon in energy efficiency management: the ISO 50001 standard

Movicon in energy efficiency management: the ISO 50001 standard Movicon in energy efficiency management: the ISO 50001 standard The importance of energy consumption within the company reflects the importance of the world energy crisis due to a growing demand and the

More information

Flexy-ble M2M router for remote access and data services. Industrial M2M Router. www.ewon.biz

Flexy-ble M2M router for remote access and data services. Industrial M2M Router. www.ewon.biz -ble M2M router for remote access and data services Industrial M2M Router www.ewon.biz -ble Industrial M2M Router FLEXY PRICE SAVE INVESTMENT 2 product families 3 base modules 20x, the M2M Router The 20x

More information

CHAPTER 12 MONITORING AND CONTROL SYSTEMS

CHAPTER 12 MONITORING AND CONTROL SYSTEMS CHAPTER 12 MONITORING AND CONTROL SYSTEMS To manage onsite wastewater treatment systems properly, monitoring of process operation and performance is necessary. Because of the increasing number and complexity

More information

Wireless Communications for SCADA Systems Utilizing Mobile Nodes

Wireless Communications for SCADA Systems Utilizing Mobile Nodes , pp. 1-8 http://dx.doi.org/10.14257/ijsh.2013.7.5.01 Wireless Communications for SCADA Systems Utilizing Mobile Nodes Minkyu Choi Security Engineering Research Support Center, Daejon, Republic of Korea

More information

Using Cellular RTU Technology for Remote Monitoring and Control in Pipeline and Well Applications

Using Cellular RTU Technology for Remote Monitoring and Control in Pipeline and Well Applications Using Cellular RTU Technology for Remote Monitoring and Control in Pipeline and Well Applications Steve Frank Business Development Manager Moxa Inc. Introduction Cellular technology minimizes site visits

More information

GSM ATT Modules Simply effective remote control

GSM ATT Modules Simply effective remote control GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential

More information

MM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure.

MM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure. MM8000 safety and security with smart danger management A scalable and flexible management station for any requirement Answers for infrastructure. Sophisticated technology for comprehensive safety Safety

More information

Your remote sites at your fingertips?

Your remote sites at your fingertips? www.klinkmann.com Your remote sites at your fingertips? Industrial M2M Router & Data gateway The ewon is the first industrial modular M2M router and data gateway designed for OEMs and system integrators.

More information

Crow Limited Warranty. Print Version 017

Crow Limited Warranty. Print Version 017 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose

More information

How To Monitor A Photovoltaic Plant Remotely

How To Monitor A Photovoltaic Plant Remotely 15P0701B100 REMOTE MONITORING SERVICES USER MANUAL Issued on 18/04/12 R.00 English This manual is integrant and essential to the services and the products described herein. Carefully read the instructions

More information

QUICK REFERENCE GUIDE MOBILE HUMAN MACHINE INTERFACE (HMI): INNOVATION THAT EMPOWERS THE MOBILE OPERATOR

QUICK REFERENCE GUIDE MOBILE HUMAN MACHINE INTERFACE (HMI): INNOVATION THAT EMPOWERS THE MOBILE OPERATOR MOBILE HUMAN MACHINE INTERFACE (HMI): INNOVATION THAT EMPOWERS THE MOBILE OPERATOR Mobile operators are critical to ensuring the overall efficiency and uptime of the production line and play a critical

More information

User manual Compact Web PLC WP240 series IEC-line

User manual Compact Web PLC WP240 series IEC-line User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys

More information

SPPA-D3000 Plant Monitor Technical Description

SPPA-D3000 Plant Monitor Technical Description SPPA-D3000 Plant Monitor Technical Description Model-based monitoring and early fault detection for components and processes May 2008 Answers for energy. 1 Siemens AG 2008. All Rights Reserved Contents

More information

The KNX visualization software

The KNX visualization software 01 The KNX visualization software Visualization software pre-installed in an industrial embedded Linux PC. Available in different hardware versions to match the requirements of any type of installation:

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency

Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency SUMMARY Recent advances in real-time water sensing technology have enabled new opportunities for improved assessment and management

More information

Flygt Aquaview SCADA Software. Safer monitoring and simpler at a glance

Flygt Aquaview SCADA Software. Safer monitoring and simpler at a glance Flygt Aquaview SCADA Software Safer monitoring and simpler at a glance Effective control, reduced operational costs Precise and easy control through the user-friendly interface. Innovative solutions from

More information

Reference report Oil & Gas

Reference report Oil & Gas Central control system for gas distribution pipelines SIMATIC WinCC Open Architecture real time data managing corporate platform implementation Until 2010, EDP Naturgas Energia had four different SCADA

More information

Failsafe Protection for Utility Critical Infrastructure

Failsafe Protection for Utility Critical Infrastructure Failsafe Protection for Utility Critical Infrastructure Introduction PUCs maintain a crucial part of the nation s CI that provide essential services to the public, business and government. Reliable CI

More information

EUROPASS DIPLOMA SUPPLEMENT

EUROPASS DIPLOMA SUPPLEMENT EUROPASS DIPLOMA SUPPLEMENT TITLE OF THE DIPLOMA (ES) Técnico Superior en Sistemas de Telecomunicaciones e Informáticos TRANSLATED TITLE OF THE DIPLOMA (EN) (1) Higher Technician in Telecommunications

More information

ACE3600 HIGH PERFORMANCE MONITORING & CONTROL REMOTE TERMINAL UNIT

ACE3600 HIGH PERFORMANCE MONITORING & CONTROL REMOTE TERMINAL UNIT HIGH PERFORMANCE MONITORING & CONTROL REMOTE TERMINAL UNIT PAGE 1 EMPOWER YOUR SCADA NETWORK Utilities, now more than ever, are facing newer and greater hurdles. Multiple wired and wireless communication

More information

INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME. Ján Cigánek, Martin Janáček, Stanislav Števo

INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME. Ján Cigánek, Martin Janáček, Stanislav Števo INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME Ján Cigánek, Martin Janáček, Stanislav Števo Slovak University of Technology Ilkovičova 3, 812 19 Bratislava, Slovak Republic Tel.: +421 2 60291111 Fax: +421 2

More information

Enabling the SmartGrid through Cloud Computing

Enabling the SmartGrid through Cloud Computing Enabling the SmartGrid through Cloud Computing April 2012 Creating Value, Delivering Results 2012 eglobaltech Incorporated. Tech, Inc. All rights reserved. 1 Overall Objective To deliver electricity from

More information

Wireless Video Best Practices Guide

Wireless Video Best Practices Guide Wireless Video Best Practices Guide Using Digital Video Manager (DVM) with the OneWireless Universal Mesh Network Authors: Annemarie Diepenbroek DVM Product Manager Soroush Amidi OneWireless Product Manager

More information

Real Time Remote Monitoring over Cellular Networks. Wayne Chen Marketing Specialist

Real Time Remote Monitoring over Cellular Networks. Wayne Chen Marketing Specialist Real Time Remote Monitoring over Cellular Networks Wayne Chen Marketing Specialist Introduction For distribution infrastructures located in remote, isolated areas, unmanned monitoring systems have long

More information

WinCon-8000. Programmable Automation. Controller

WinCon-8000. Programmable Automation. Controller Programmable Automation Controller Introduction The is a leading edge embedded platform with Intel Strong ARM CPU running the Windows CE.NET operating system. When compared to the standard Windows OS,

More information

Remote Services. Managing Open Systems with Remote Services

Remote Services. Managing Open Systems with Remote Services Remote Services Managing Open Systems with Remote Services Reduce costs and mitigate risk with secure remote services As control systems move from proprietary technology to open systems, there is greater

More information

Optical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance

Optical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance Optical Network Management System Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance JDSU Enabling Broadband and Optical Innovation Improving the

More information

MicroSCADA Pro. System Configuration. Configuration Manual

MicroSCADA Pro. System Configuration. Configuration Manual SYS 600 9.2 1MRS756112 Issued: 31.12.2007 Version: B/31.12.2007 SYS 600 9.2 Contents Copyrights... 9 1. Introduction...11 1.1. This manual...11 1.2. Use of symbols...11 1.3. Intended audience...11 1.4.

More information

Monitoring Underground Power Networks

Monitoring Underground Power Networks Monitoring Underground Power Networks By Mark Stiles Merve Cankaya ABSTRACT Underground electric distribution systems are common in large cities throughout the United States. Power usage for the entire

More information

Trådløs forbindelse. Juni 2011. Peter Fuglsang Product Application Engineer Automation

Trådløs forbindelse. Juni 2011. Peter Fuglsang Product Application Engineer Automation Trådløs forbindelse Juni 2011 Peter Fuglsang Product Application Engineer Automation Trådløs kommunikation Definition af netværk Trådløse produkter fra Schneider Electric RTU moduler Trådløse Løsninger

More information

Operations Manager Comprehensive, secure remote monitoring and management of your entire digital signage network infrastructure

Operations Manager Comprehensive, secure remote monitoring and management of your entire digital signage network infrastructure Network monitoring, management and maintenance 3M TM Network Operations Manager Comprehensive, secure remote monitoring and management of your entire digital signage network infrastructure Provides real-time

More information

File Replication plus NAS enables Server-Less Remote Site Backup

File Replication plus NAS enables Server-Less Remote Site Backup LinkPro Technologies File Replication plus NAS enables Server-Less Remote Site Backup "Storage acquisition and management is undergoing great changes, stimulated by new applications, a growing need for

More information

VISUALFLEET Software Overview

VISUALFLEET Software Overview soft-in VISUALFLEET Software Overview SOFTWARE PER SISTEMI INDUSTRIALI - Strada Antica di None 2/4A - 10092 BEINASCO (TO) - ITALY Tel.: +39-011-39.87.711 - Fax: +39-011-39.87.727 1 INTRODUCTION The VisualFleet

More information

Ultimate Server Client Software

Ultimate Server Client Software Ultimate Server Client Software GPRS NET Data Logger Ul mate Server is dedicatedly developed for high volume data applica on. 1. Receive data from Data Loggers in UDP or TCP via GPRS, Ethernet and SMS

More information

Introduction. Background

Introduction. Background Predictive Operational Analytics (POA): Customized Solutions for Improving Efficiency and Productivity for Manufacturers using a Predictive Analytics Approach Introduction Preserving assets and improving

More information

EC 350 Simplifies Billing Data Integration in PowerSpring Software

EC 350 Simplifies Billing Data Integration in PowerSpring Software White Paper EC 350 Simplifies Billing Data Integration in PowerSpring Software Executive Summary In the current energy environment, gas-metering data must be collected more frequently and in smaller increments

More information

Nokia E61i Configuring connection settings

Nokia E61i Configuring connection settings Nokia E61i Configuring connection settings Nokia E61i Configuring connection settings Legal Notice Copyright Nokia 2007. All rights reserved. Reproduction, transfer, distribution or storage of part or

More information

A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES

A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES A Roberts, T Berry, W D Wilson Schneider Electric Ltd, UK SYNOPSIS This paper describes the features of a modern Distribution

More information

straton Universal control and strong connections. embedded field bus controller soft-plc scada logic

straton Universal control and strong connections. embedded field bus controller soft-plc scada logic straton Universal control and strong connections. embedded field bus controller soft-plc scada logic SCADA Logic, Soft-PLC, embedded field bus controller: straton is the universal perfect solution, with

More information

Intelligent Network Management System. Comprehensive Network Visibility and Management for Wireless and Fixed Networks

Intelligent Network Management System. Comprehensive Network Visibility and Management for Wireless and Fixed Networks Intelligent System Comprehensive Visibility and for Wireless and Fixed s Performance Analysis Made Easy With the increase in wireless network sizes and network complexities and the inter-operation of diverse

More information

Teldat Security IP & Wireless GSM/GPRS Alarm Communicators

Teldat Security IP & Wireless GSM/GPRS Alarm Communicators Teldat Security IP & Wireless GSM/GPRS Alarm Communicators Taking the alarm industry into the internet world For more than twenty years, Teldat has been at the forefront of technology, launching various

More information

The Research on Industrial Information Monitoring System Based on B/S Structure Xuexuan ZHU1, a

The Research on Industrial Information Monitoring System Based on B/S Structure Xuexuan ZHU1, a 4th National Conference on Electrical, Electronics and Computer Engineering (NCEECE 2015) The Research on Industrial Information Monitoring System Based on B/S Structure Xuexuan ZHU1, a 1 College of Electrical

More information

totalflow SoftwaRE SYStEMS

totalflow SoftwaRE SYStEMS totalflow SOFTWARE SYSTEMS Connect And Control With ABB Totalflow. No matter the size of your operation, there is an ABB Totalflow software system designed to help you collect, configure, manage and distribute

More information

Industrial HiVision Software

Industrial HiVision Software Industrial HiVision Software The Essential Management Tool For All Stages of Your Network Life Cycle Network visibility equals high availability. Industrial HiVision is a state-of-the-art software package

More information

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations 2 One Solution for Monitoring, Control or Both There are many ways to improve the efficiency and reliability of your

More information

Secure access to a water treatment plant s SCADA network

Secure access to a water treatment plant s SCADA network Secure access to a water treatment plant s SCADA network Sharp reduction in maintenance times The systems integrator Morehouse Engineering has helped users operating in many different industries implement

More information

Remote monitoring & control solutions for cathodic protection rectifier

Remote monitoring & control solutions for cathodic protection rectifier G Remote monitoring & control solutions for cathodic protection rectifier FF-Automation Finnish automation manufacturer company Focused on remote monitoring & control solutions AutoLog RTU Series AutoLog

More information

Protection and Substation Automation. Training Programmes

Protection and Substation Automation. Training Programmes Protection and Substation Automation Training Programmes Protection and Substation Automation Training Programme Overview The objective of the Training Program is to provide education and training to make

More information