OPERATING MANUAL MK-367 LASER COMPONENTS KIGRE, INC.
|
|
|
- Basil Stevens
- 8 years ago
- Views:
Transcription
1 OPERATING MANUAL MK-367 LASER COMPONENTS KIGRE, INC. PLEASE READ THE ENTIRE OPERATIONS MANUAL TO FAMILIARIZE YOURSELF WITH THESE COMPONENTS BEFORE SETTING UP AND/OR OPERATING THE KIGRE LASER. IF YOU HAVE ANY QUESTIONS OR COMMENTS REGARDING THE SAFETY, OPERATION, OR MAINTENANCE OF THIS SYSTEM PLEASE CONTACT OUR CUSTOMER SERVICE DEPARTMENT AT: KIGRE INC., 100 MARSHLAND RD, HILTON HEAD ISLAND, SC, PHONE: FAX: WEB: MK367 Laser Components Operating Manual v4 Page 1
2 INITIAL INSPECTION Please inspect the shipment immediately upon delivery. Check the received goods against the packing list to insure that all items were received. If the shipment is missing items, or is damaged in any way, you will need to contact the freight carrier. You should also contact Kigre's Customer Service Department (the address is on the front page) or your local Representative for assistance with your claim. WARRANTY Unless otherwise specified, all laser power system products manufactured by Kigre are warranted to be free from defects in workmanship and materials for a period of one (1) year following delivery of the equipment to the F.O.B. point. Liability under this warranty is limited to, at Kigre's option, repairing or replacing the part or product which is determined by Kigre to be defective during this warranty period, provided prior authorization for such return has been given by an authorized representative of Kigre and the product is returned, prepaid, to Kigre within thirty (30) days from discovery of the defect. Equipment repaired or replaced under warranty are warranted only for the remaining unexpired portion of the original warranty period. This warranty does not apply to laser power system products which upon inspection by Kigre are determined to have been damaged through improper storage or installation, misuse, neglect, accident, or for any cause beyond Kigre's control. Repair or alteration of any part of the laser power system by person other than Kigre authorized personnel immediately voids this warranty. Buyer assumes all risk and liability for the results obtained by the use of any product delivered hereunder and in no event shall Kigre be held responsible for special or consequential damages or charges. When products manufactured by others are used in conjunction with Kigre equipment, this warranty only extends to the equipment manufactured by Kigre. This warranty is in lieu of any and all warranties or representations, expressed or implied, and no agreement or understanding affecting this warranty shall be binding upon Kigre unless in writing and signed by an authorized representative of Kigre. Kigre reserves the right to make changes to its products without incurring the obligation to incorporate such changes in products previously purchased and delivered to the buyer. RETURN PROCEDURE Your Kigre laser system is designed and constructed to provide years of trouble free service. Should your system require service, return it to our service facility by contacting our Customer Service Department for a Return Material Authorization number (RMA#). You will need to provide the model and serial number of the damaged equipment and a brief description of the failure. Return shipments should be made prepaid. Kigre will not accept C.O.D. or collect return shipments. Damages caused by inadequate packaging will not be covered under the warranty. MK367 Laser Components Operating Manual v4 Page 2
3 LASER SAFETY INFORMATION LASER SAFETY WARNING The MK367 laser is a Class IV device and proper eye safety must always be used. As with any laser, never look directly at the laser in the beam path. The laser is too small to accept identification or warning labels so they are located here. It is the responsibility of the end-product manufacturer to create and apply any external labels as required by federal and local laws. In the United States of America (USA), all labels must conform to FDA regulation 21 CFR Ch.1, Only qualified personnel that are trained in solid-state laser applications should operate these systems. The laser should always be operated in a relatively clean environment. LASER HANDLING INFORMATION As with all laser devices, the resonator must be handled carefully. Never touch the optical surfaces of the laser. Check the optical surfaces for cleanliness using a microscope and clean only if needed. The optical surfaces should only be cleaned as a corrective action for marked power decrease or poor mode quality and should not be cleaned unless signs of contamination are clearly visible on the optical surfaces. Unnecessary cleaning will only shorten the life span of the optical coating. Handle laser optics with care. A scratch, trace of dirt, or film will diminish the laser's efficiency. Before cleaning optics insure your hands are clean and a clean work surface is available. Place a drop of Methanol in the center of a lens tissue. Place the wet portion of the lens tissue on the optic surface and slowly drag it across the optic. Make a single swipe across the surface of the optic. The lens tissue and optic should be nearly dry before completing the drag. Do not re-use the lens tissue as particles of dust and other contaminates picked up from the surface of the optic may scratch if dragged across with a second swipe. The laser may need to be held in place during this process. Examine the surface of the optic. If streaks or contamination can be seen, repeat the cleaning process using a fresh lens tissue. MK-367 LASER CHARACTERISTICS The MK-367 (or MK-480) laser was developed primarily for the ophthalmic and range-finder markets as a permanently aligned, reliable, low cost laser requiring minimal service and having a usable life in excess of 300,000 shots. NOMINAL OUTPUT mj WEIGHT 59 grams POLARIZATION... > 99.7 % NOMINAL PULSE WIDTH... < 4 ns BEAM DIAMETER... 3 mm BEAM DIVERGENCE... 20% ~ 1.1 mrad full angle OUTPUT STABILITY... < +/- 10% MAXIMUM REPETITION RATE... 1 Hz BEAM MODE... Low Order. NOMINAL REQUIRED INPUT... 5J/pulse (see Laser Checkout Sheet for details) LIFETIME... > 300,000 shots in single-pulse output mode. Flashlamp lifetime is shortened significantly if the unit is operated in multiple-pulse output mode or fired continuously at external temperatures above 40 o C. MK367 Laser Components Operating Manual v4 Page 3
4 POWER SUPPLY SPECIFICATIONS 1 AC to DC Power Supply Elpac # W VDC, 4A output (2.5mm barrel plug connector) VAC, 1.6A, 50-60Hz input 2 Hand Controller 12VDC input connector ON/OFF toggle (enables HV) Fire toggle HV program adjustment dial HV monitor output (SMA connector). 1/100V scale. External Fire BNC (short BNC contacts to fire; typically used with a footswitch, relay, opencollector transistor, or opto-isolator). BNC part number is Amphenol # DO NOT APPLY VOLTAGE TO THIS BNC. DO NOT GROUND. Use isolated contacts only. 3 PFN and HVPS MK units: 6W, 20uF, 20uH 2.5-9J at V output. 2.5lb (1.13kg) MK units: 6W, 40uH, 40uH 5-11J at V output. 2.8lb (1.26kg) 12VDC 1.5A input (charging) 12VDC 0.3A input (regulating) 4.00" x 6.00" x 1.75" (refer to attached DWG #A1964 Rev1) 4. Trigger Module Mounts directly to MK series lasers. 10KV pulsed output to ionize flashlamp (hard trigger). 3.6 x 0.8 x 0.7 (not including cable) No scheduled maintenance is required. Failure symptoms should be identified to the module if possible. The factory will repair units or sub-assemblies at the prevailing labor and material rates. Please ensure a complete description is given of all symptoms and events leading to failure. This may reduce repair time. MK367 Laser Components Operating Manual v4 Page 4
5 CONTROL I/O PINOUT INFORMATION CONTROL I/O PINOUT (Amphenol #17D-DE-9P, 9pin Dsub connector) 1) 12VDC 1.2A input positive. 2) 12VDC negative (return). Also used as trigger return. 3) Trigger input. 10Kohm input resistance. Requires volt amplitude, 100uS pulsewidth. 4) Charge indication output. 12V signal via a 22Kohm current limiting resistor indicates that the PFN is not fully charged. The laser is ready to fire when this signal goes to 0 volts. 200mA sink. 5) Program voltage input: 10Kohm potentiometer - CW. 6) Program voltage input: 10Kohm potentiometer - WIPER. 7) Program voltage input: 10Kohm potentiometer - CCW. 8) Scaled HV monitor. Output voltage = 1/100 of the actual flashlamp high voltage. 9) Not used. WARNING: A 10Kohm potentiometer must be connected to pins# 5, 6, and 7 before power is applied to pin #1. Otherwise, damage to the unit will result! LASER PINOUT (ITT-Cannon #DEM-5WIS, Combo D-sub connector with HV pin: ITT-Cannon #DM51155) A1) HV OUTPUT volt high voltage output to flashlamp anode (positive) 1) TRIGGER + 300V 100mS pulse to trigger transformer for lamp ionization. 2) OUTPUT RETURN Common return for pins #A1 and 1. CONTROL I/O CONNECTOR LASER CONNECTOR MK367 Laser Components Operating Manual v4 Page 5
6 INSTALLATION 1. Remove power supply, laser, trigger module, and hand controller from the packing material. Carefully unwrap each item and inspect for damage. Please contact Kigre, Inc. immediately if any damage is suspected. 2. Connect the laser head to the trigger module. Align the three pins and gently push together until secure. Mount laser head as desired (refer to laser head mounting drawings on following pages). 3. Connect the trigger module to the HV power supply (unit with PFN). Align the plastic connector, push in and turn to secure. 4. Connect the hand controller to the HV power supply. Align the 9pin D-sub connector and push to secure. Refer to the Control I/O Pinout information above when not using the Kigre hand controller. 5. Attach the hand controller to your DVM meter with the supplied adapter cable and adapter plug as shown. Set the meter to the 20VDC scale or equivalent. The high voltage setting should be monitored via the hand controller s SMA connector. Use the supplied adapter cable to connect the SMA connector to a Digital Volt Meter (DVM). The scale factor is 1/100 (1 volt output = 100 volts actual on the PFN). Please note: An external fire BNC is available on the hand controller. Short the BNC contacts to fire. This connector is typically used with a footswitch, relay, opencollector transistor, or opto-isolator. DO NOT APPLY VOLTAGE TO THIS BNC. DO NOT GROUND. Use isolated contacts only. 6. Connect the AC/DC PS unit (12VDC, >35W, 2.5mm Ø pin, center pin is positive) to the hand controller. The supplied AC-DC power supply unit has a universal input range of VAC and works with both 50 and 60Hz AC input. MK367 Laser Components Operating Manual v4 Page 6
7 INSTALLATION (CONTINUED) HAND CONTROLLER MK367-HC Please note: Proper clamping of the MK367 laser is essential for reliable energy and beam quality, especially over temperature. Uniformly clamp only the flat surfaces in the center of the laser as shown. Do not attempt to clamp the ends of the laser as this will distort the laser beam. Please refer to the following drawings for reference. Please note: The 300,000 to 1,000,000 shot flash-lamp life of these units will be significantly shortened if the unit is operated in multiple-pulse (burst) output mode or fired continuously at external temperatures above 40 o C. MK367 Laser Components Operating Manual v4 Page 7
8 OPERATION 1. Refer to the laser s checkout sheet, included with the laser shipment. Near the bottom right of the checkout sheet (in the Final Burns section) is the recommended operating voltage (input energy) setting required for proper single shot laser output. The voltage value will be listed as the 60% above SP value. EXAMPLE DATA 2. Connect a volt meter (DVM) to the Scaled Voltage Monitor connector using the supplied adapter cable. Set the meter to the 20VDC or similar scale. This meter will be used to set the proper operating voltage (input energy). The Scaled Output monitor has a 1/100 ratio so 557 volts, for example will be 5.57 volts on the DVM meter. 3. Start at a lower energy setting until you are familiar with the unit's operation. Adjust the HV ADJ adjustment knob on the hand controller fully to the left (CCW) to begin. 4. Turn the toggle switch on the hand controller up to enable the high voltage power supply. The DVM should display ~ 0 volts. Gradually turn the HV ADJ knob clockwise (CW) to increase the high voltage value until it equals the recommended 60% above SP setting. SP stands for Single Pulse and is the recommended operating mode for the MK367 laser. Operating the laser at higher voltages (higher input energies) will drastically reduce the laser s lifetime. Specifically, it will reduce the flashlamp lifetime to approximately 30,000 shots well below the normal 300,000 + shot lifetime for the MK367 laser in single output pulse mode. 5. Momentarily press the fire button on the hand controller to fire the laser. WARNING: A sufficient bleed time of at least three (3) minutes should be allowed before handling any high voltage components or connections! MK367 Laser Components Operating Manual v4 Page 8
9 ENGINEERING NOTES 1) Use an energy detector, such as the Molectron Energy Max 500 Display and J25 detector shown, to verify laser output performance before installing these components. An Ophir Vega energy meter with Ophir PE25BF-DIF-C detector with diffuser can also be used. The Kigre MK367 laser uses a passive Q-switch to produce a short pulsewidth, high peak power laser output pulse. The output energy is determined by the Q-switch material and is not user adjustable. Slight variations in output energy are normal and are due to the nature of the passive Q-switch material. 2) These high peak power transmitters should NOT BE FIRED DIRECTLY INTO A HIGHLY REFLECTIVE NEAR FIELD SURFACE! Back reflected radiation may cause damage to the rod and Q-switch. Please call Kigre sales for more information. 3) MK-Series laser are capable of continuous operation at up to 1/3 Hz maximum rep-rate when properly mounted in an equivalent heat sink fixture to Kigre's # MK Up to 1Hz continuous duty operation is possible with the aircooled MK-367AC or when the MK-367 is mounted in a water-cooled mount such as the Kigre MDL# MK The 300,000 to 1,000,000 shot flash-lamp life of these units will be significantly shortened if the unit is operated in multiple-pulse (burst) output mode or fired continuously at external temperatures above 40 o C. MK367 Laser Components Operating Manual v4 Page 9
10 ENGINEERING NOTES (CONTINUED) 4) When holding the laser, use only the two flat mounting surfaces near its middle. The Kigre drawing A1140-A in this manual gives a good example. Gentle, even pressure in this area is best. A small amount of thermal grease helps improve thermal conductivity between the laser and heatsink mount. Never attach anything to the ends of the laser as doing so can move the OC or HR mirrors out of alignment. 5) Each laser is shipped with test data as shown at the end of this manual. Please note the single and double pulse threshold voltages indicated on the test sheet. For reliable single pulse laser output, it is best to operate 50-60% of the way between these two voltage values. You set the high voltage level via the program pins on the power supply's 9-pin D-sub connector. 6) The voltage program pins have a range of volts input = volts output. In other words: 2V=400V; 3V=600V; 3.5V=700V, etc. To determine the proper input voltage for your laser, the best method is to start at about 2V and gradually increase until the laser starts lasing. Due to the passive Q-switch design of this laser, there will be no laser output until the pump energy exceeds the proper threshold. Keep increasing the program voltage until the laser starts to double pulse. You can easily see this using a laser energy meter. Then lower your program voltage until it is 1/2 way between the single and double pulse threshold values. Pin 6 is the program voltage + input and pin 7 is the program voltage return input. An alternative method is to use a 10K-ohm trimpot between pins 5, 6, and 7 as indicated on page 4 of the manual. In either case, never exceed 3.75 volts input (~750V). 7) The actual high voltage setting can be monitored using pin 8 of the D-sub connector. Pin 2 is the return. Pin 8 has a 1/100 volt scale. In other words, a 500 volt setting equals 5.00 volts on this pin. However, you must use a high impedance device to measure this voltage. A DVM meter works best. Do not use a probe or scope with < 50 mega-ohms or it will alter the voltage scale. For example, don't directly use the 1 Mega-ohm scope input to measure this voltage. Rather, use the scope with a 10x logic probe. Once the program voltage is set properly for the laser, you should not need to continually change it. MK367 Laser Components Operating Manual v4 Page 10
11 ENGINEERING NOTES (CONTINUED) The 300,000 to 1,000,000 shot flash-lamp life of these units will be significantly shortened if the unit is operated in multiple-pulse (burst) output mode. MK367 Laser Components Operating Manual v4 Page 11
12 MK367 LASER OUTLINE MK367 Laser Components Operating Manual v4 Page 12
13 LASER MOUNT ASSEMBLY # A1140 MK367 Laser Components Operating Manual v4 Page 13
14 LASER MOUNT DRAWING # A1142 LASER CLAMP DRAWING # A1143 MK367 Laser Components Operating Manual v4 Page 14
15 POST-MOUNT TILT-BASE ASSEMBLY MK367 Laser Components Operating Manual v4 Page 15
16 MK106 POWER SUPPLY OUTLINE MK lb (1.13kg) Potted MK lb (1.26kg) Potted MK lb (224g) Unpotted MK367 Laser Components Operating Manual v4 Page 16
17 MK367HC HAND CONTROLLER OUTLINE MK367TM TRIGGER MODULE OUTLINE MK367-TM Trigger Module 54 grams potted MK HEAT-SINK MOUNT KIGRE DRAWING # A1140 PB-250 POST-MOUNT TILT BASE KIGRE DRAWING # A617 MK367 Laser Components Operating Manual v4 Page 17
18 OPTIONS MKG-367 Laser Head with Frequency Doubled 532nm & 1064nm Output MK367 Laser Components Operating Manual v4 Page 18
19 OPTIONS (CONTINUED) MKG-367 Laser Head with Frequency Doubled 532nm & 1064nm Output MK367 Laser Components Operating Manual v4 Page 19
20 OPTIONS (CONTINUED) MK-367AC Laser Head with Forced Air Cooling Option (example in-line air filter shown) MK367 Laser Components Operating Manual v4 Page 20
21 OPTIONS (CONTINUED) MK-367-M Laser Head with Trigger Transformer in Cable Option REMI-367 Laser Head in Aluminum Enclosure for Coherent Series MK367 Laser Components Operating Manual v4 Page 21
22 TEST DATA, 100 SHOT ENERGY GRAPH SAMPLE MK367 Laser Components Operating Manual v4 Page 22
23 TEST DATA, LASER CHECKOUT SHEET SAMPLE MK367 Laser Components Operating Manual v4 Page 23
Amplified High Speed Fiber Photodetectors
Amplified High Speed Fiber Photodetectors User Guide (800)697-6782 [email protected] www.eotech.com Page 1 of 7 EOT AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified
INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE
INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE VINCENT ASSOCIATES 803 LINDEN AVE. ROCHESTER, NEW YORK 14625 SERVICE/ORDERS (800) 828-6972 In NY State (585) 385-5930 Fax (585) 385-6004
Load Cell Amplifier Module. Instruction Manual LCA210-000
Load Cell Amplifier Module Instruction Manual LCA210-000 Table of Contents 1. General Description...3 2. Specifications...3 2.1 Electrical...3 2.2 Physical...4 3. Installation...4 3.1 Wiring Guidelines...4
OPERATING INSTRUCTIONS
PIPELINE INSPECTION COMPANY LTD. OPERATING INSTRUCTIONS Wet Sponge Holiday Detectors 670,673, and MSRB Wet Sponge Holiday Detectors Portable and In-Plant Detectors Table of Contents General Information.......................3
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:
LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions
LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions Description The LS-1 Series of tungsten halogen light sources are versatile, white-light lamps optimized for use in the
User Manual. CFG253 3 MHz Function Generator 070-8362-04
User Manual CFG253 3 MHz Function Generator 070-8362-04 Copyright Tektronix, Inc. 1993. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information
Quasi-Continuous Wave (CW) UV Laser Xcyte Series
COMMERCIAL LASERS Quasi-Continuous Wave (CW) UV Laser Xcyte Series Key Features 355 nm outputs available Quasi-CW UV output Field-proven Direct-Coupled Pump (DCP ) TEM00 mode quality Light-regulated output
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.
*00151* FEATURES Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. Silicon diodes with inherent surge protection operated at a conservative
PagePac PAGEPAL V-5335700
PagePac Issue 3 by PAGEPAL V-5335700 INTRODUCTION The PagePal unit interfaces most telephone systems (PBX, KTS, Centrex) to virtually any public address audio system. In addition, PagePal furnishes inputs
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
Global Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Solar Panels 2 Watt Solar Panel: SP101 5 Watt Solar Panel: SP102 01-752
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
SX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.
BLWR23MDA Series 24V, 15A Brushless Controller / Motor User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected] (714) 992-6990 fax:
PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790
PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790 Safety Disclaimer Only trained and responsible personnel should
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
User Guide. HDMI Active Cable Extender. DVI-7370c
User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0 CONNECTING
Series AMLDL-Z Up to 1000mA LED Driver
FEATURES: Click on Series name for product info on aimtec.com Series Up to ma LED Driver Models Single output Model Input Voltage (V) Step Down DC/DC LED driver Operating Temperature range 4ºC to 85ºC
PEDAL POWER. User s Manual
PEDAL POWER AC User s Manual Copyright 2005-2008 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by
Global Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 6 Tipping Bucket: RG200 02/05/10 01-343 - 1 - Congratulations on your
NLC 800 Air-Cooled Argon-ion Laser
NLC 800 Air-Cooled Argon-ion Laser User s Manual Complete with Operating Instructions for the 8470 and 2270 Power Supply TABLE OF CONTENTS CHAPTER 1: INTRODUCTION 1 CHAPTER 2: LASER SAFETY 2 CENTER FOR
HVA200 High Voltage Amplifier
HVA200 High Voltage Amplifier Operating Manual Table of Contents Part 1. Important Safety Notice... 3 Part 2. Product Overview... 4 Part 3. Setup and Operation... 5 3.1. HVA200 Controls and Features...
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM
Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed
MDC151-024031 Series
MDC151-024031 Series 24V, 3A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected] (714) 992-6990 fax: (714)
VK-250 WARRANTY REGISTRATION FORM
VK-250 WARRANTY REGISTRATION FORM Unit Serial Number: Customer Name: Address: Date of Purchase: Purchased From: Dealer Name: Address: IMPORTANT NOTE: In order to receive the full five year product warranty,
CONTROL SWITCHER User s Manual (Preliminary)
CONTROL SWITCHER User s Manual (Preliminary) www.voodoolab.com Copyright 2010 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. Voodoo Lab, Control Switcher,
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
SYSTEM 45. C R H Electronics Design
SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual
DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
V-2901 UNIVERSAL DOOR ANSWERING SYSTEM
VSP-V-2901 Issue 6 V-2901 UNIVERSAL DOOR ANSWERING SYSTEM INTRODUCTI The V-2901 is a Universal Door Answering System for use with any single line telephone, electronic or 1A2 key system, or PABX. These
MODEL 2202IQ (1991-MSRP $549.00)
F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR
INSTALLATION & OPERATION MANUAL LED
INSTALLATION & OPERATION MANUAL LED Duo Beam TM Introduction... 2 Lightbar Unpacking & Pre-Installation... 2 Installation & Mounting... 3 Wiring Instructions... 4 Maintenance... 4 Flash Pattern Selection...
user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4
user s manual model #: SPB3200 Charger for Samsung Galaxy S 4 What s Included Unpack the battery case and make sure all accessories are put aside so they will not be lost. hello. USB to Micro USB Cable
Seven function digital multimeter
Seven function digital multimeter 98025 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.
- Easy -wire installation with no external spark box necessary, but can be used with one. - Precision CNC machining and hand assembled construction. This is a premium product. - Accurate super hot spark
AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE
AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified High Speed Fiber Photodetector. This user s guide will help answer any questions you may have regarding the
Instruction Manual. This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E 300-3.5E 50-20E 600-1.7E
DCS-E SERIES POWER SUPPLIES Instruction Manual This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E 300-3.5E 50-20E 600-1.7E SORENSEN Division of Elgar 9250 Brown Deer Road San Diego,
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
7 FUNCTION DIGITAL MULTIMETER
7 FUNCTION DIGITAL MULTIMETER 90899 OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight Tools. All rights
PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS
PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS The end of a fiber optic cable and the inner surface of an optical module lens constitute optical surfaces that should be properly cleaned and maintained
TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4
User Manual TABLE OF CONTENTS 1. BEFORE YOU BEGIN... 3 What Is Included... 3 Unpacking Instructions... 3 Claims... 3 Product at a Glance... 3 Safety Instructions... 4 2. INTRODUCTION... 5 Product Overview...
i410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
Infrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
OPERATING INSTRUCTIONS FOR LED-4 MULTI-SPORT TABLETOP SCOREBOARD
OPERATING INSTRUCTIONS FOR LED-4 MULTI-SPORT TABLETOP SCOREBOARD OVERVIEW The LED-4 is a portable tabletop scoreboard that employs LED (Light Emitting Diode) display technology, offering tens of thousands
PEDAL POWER 4x4. User s Manual. www.voodoolab.com
PEDAL POWER 4x4 User s Manual www.voodoolab.com Copyright 2009-2012 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. Voodoo Lab and Pedal Power are
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
AGS. Owner's Manual. Xantrex Automatic Generator Start Control System
AGS Owner's Manual Xantrex Automatic Generator Start Control System TABLE OF CONTENTS INTRODUCTION...3 Main Features...3 Safety Summary...3 THINGS YOU SHOULD KNOW...4 THEORY OF OPERATION...5 System...5
Laserlyte-Flex Alignment System
Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning
Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS
Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS Operation Manual Read Before Using LUMI-TENS-INS-LAB-RevA08 TABLE OF CONTENTS INTRODUCTION TO TENS INDICATIONS AND CONTRAINDICATIONS WARNINGS
Ultrasonic Distance Meter. Operation Manual
XPROTEC Ultrasonic Distance Meter Operation Manual About XProTec Pro-Installer Tools The XProTec line from XFTP is a comprehensive lineup of professionalgrade technical tools. These full-featured, field-proven,
Lab 9: The Acousto-Optic Effect
Lab 9: The Acousto-Optic Effect Incoming Laser Beam Travelling Acoustic Wave (longitudinal wave) O A 1st order diffracted laser beam A 1 Introduction qb d O 2qb rarefractions compressions Refer to Appendix
AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E
AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E SENS part no: 101314 Document revision: F DCN No. 106811 Date 8/3/15 1840 Industrial Circle Longmont, CO 80501 Fax: (303) 678-7504
GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847 673-5009 email@gaertnerscientific.
7109-C-244E-R1 Field Installation of HeNe Laser in B, C, and D-Type Auto Gain Ellipsometers GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847
WATERBUG@ INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007
WATERBUG@ INSTALLATION / OWNERS MANUAL MODEL WB-200 PN # D-01 l-0007 REV B INTRODUCTION Thank you for your purchase of the Winland WaterBug@ mode I WB-200. The WaterBug@ is completely electronic and is
Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080
Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 FOR SERVICE ASSISTANCE U.S. AND CANADA CALL: 1-877-854-8006 24 HOURS/DAY 7 DAYS/WEEK TABLE OF CONTENTS
Current Probes. User Manual
Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall
Brushless DC Motor Controller Product Specification Assembly 025F0129
Brushless DC Motor Controller Product Specification Assembly 025F0129 September 16, 2009 025F0129 ST B Brushless DC Motor Controller Data Sheet Page 1 Revision History ECN # Date Rev Description By 07058
WARNING: This product contains chemicals known to the state of California to cause cancer, or birth defects or other reproductive harm.
WARNING: This product contains chemicals known to the state of California to cause cancer, or birth defects or other reproductive harm. 9780 SW Freeman Drive Wilsonville, OR 97070 USA Tel: 800-442-2406
SYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
AEROMOTIVE Part # 16302 INSTALLATION INSTRUCTIONS
AEROMOTIVE Part # 16302 INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that this installation be carried
22.302 Experiment 5. Strain Gage Measurements
22.302 Experiment 5 Strain Gage Measurements Introduction The design of components for many engineering systems is based on the application of theoretical models. The accuracy of these models can be verified
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
RX-18B ORDERCODE D3314
RX-18B ORDERCODE D3314 Congratulations! You have bought a great, innovative product from DAP Audio. The DAP Audio RX-18B brings excitement to any venue. Whether you want simple plug-&-play action or a
LASER DIAGRAM TABLE OF CONTENTS. SKY Technologies Inc. www.skytechlasers.com. Laser Diagram. Technical Specifications. Laser Operation.
TABLE OF CONTENTS LASER DIAGRAM Laser Diagram 1 Technical Specifications 2 Laser Operation 3 Laser Safety 5 Maintanence 6 Limitation of Liability 7 Warranty 8 Laser Pointer Series Operations Manual Page
GLOLAB Two Wire Stepper Motor Positioner
Introduction A simple and inexpensive way to remotely rotate a display or object is with a positioner that uses a stepper motor to rotate it. The motor is driven by a circuit mounted near the motor and
el-720 Carbon Dioxide Gas Leak Detector User s Guide
el-720 Carbon Dioxide Gas Leak Detector User s Guide Congratulations on the purchase of the AccuTools el-720 Carbon Dioxide Gas Leak Detector, the most technologically advanced instrument of its kind.
PowerStar Mini Triple Play TM
PowerStar Mini Triple Play TM High Capacity, Quiet Power Distribution for Bag & Small Cart Use Three (3) Power Inputs, each with Up to 5 Amp Capacity Nine (9) Main Power Outputs, One always on 10 Amps
2. Remove rear cover of head lamp if bulbs are covered/sealed within the housings, and remove halogen bulb carefully.
These instructions are designed to address most general installation procedures across vehicles and should not be considered vehicle make, model or year specific. Please contact the vendor directly for
SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II
BLUE SKY RESEARCH The SpectraTec II, two wavelength laser module is a highly integrated system comprised of two lasers, individual driving and temperature control electronics, wavelength combining, and
PEDAL POWER 2 PLUS. User s Manual
PEDAL POWER 2 PLUS User s Manual Please visit our web site at: www.voodoolab.com Copyright 1998-2010 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved.
Example of SOP for IR Laser
Example of SOP for IR Laser Standard Operating Procedures (SOP) for Class 4 HPD semiconductor Laser Manufacturer HPD Building & Room Number EH&S 101 Model Number HPD-1/100/975 Laser Class 4 Serial Number
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams
Research Isometric Transducer 0 to 5 grams and 0 to 50 grams User's Manual Research Isometric Transducer 0 to 5 g and 0 to 50 g, 110 VAC/60 Hz MA1 72-4481 Research Isometric Transducer 0 to 5 g and 0 to
PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Installation Instructions
520 Installation Instructions Thank you very much for purchasing PIAA product. Please read this entire manual before installation and use of this product. For Installers Please give this Installation Manual
Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.
Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver. OWNER'S MANUAL VR36A XC18A XM13A MODEL VK69A (INCLUDES XC18A CAMERA, XM13A
Installation and Operation Guide for PD4100 Series Power Control Centers
Installation and Operation Guide for PD4100 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as
IR Repeater. Operation Manual P8620
IR Repeater Operation Manual P8620 Congratulations on your purchase of the P8620 IR Repeater. This operating manual will provide a guide to installation and operation of the product. Please read thoroughly
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
Weather Radio Alarm Clock
1200093 User s Guide Weather Radio Alarm Clock Thank you for purchasing your Weather Radio Alarm Clock from RadioShack. Please read this user s guide before installing, setting up, and using your new weather
Unattended Answering Device Instruction Manual
Model 3137B Unattended Answering Device Instruction Manual Monroe Electronics 100 Housel Ave Lyndonville NY 14098 800-821-6001 585-765-2254 fax: 585-765-9330 monroe-electronics.com Printed in USA Copyright
Powerware Relay-Serial Card User s Guide
Powerware Relay-Serial Card User s Guide Special Symbols The following are examples of symbols used on the UPS and accessories to alert you to important information: This symbol indicates that you should
Portable Holiday Detectors
PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors Pipeline Inspection Co. Shipping Address: 1919 Antoine Houston, Texas 77055 www.picltd.com Tel: 713/681-5837 Fax: 713/681-4838 E-mail: [email protected]
User and Installation Guide
Connect the AC adapter with the amplifier BEFORE plugging the AC adapter into an outlet to avoid spark generation! User and Installation Guide BlueFIDELITYTM Bluetooth Audio Amplifier Model 300 Contents
AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power
VEC173 ONE YEAR LIMITED WARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, regarding this product.
RADIANT PLASMA 4700 Plasma Spark Generator
RADIANT PLASMA 4700 Plasma Spark Generator Installation Guide / User Manual A S P A R K O F F R E S H A I R Aquapulser.com Contents 1 Introduction 2 1.1 About the Product....................................
Single Photon Counting Module COUNT -Series
Description Laser Components COUNT series of s has been developed to offer a unique combination of high photon detection efficiency, wide dynamic range and ease of use for photon counting applications.
USB 2.0 4-Port Hub with USB Power Cable. User s Manual
USB 2.0 4-Port Hub with USB Power Cable Model: UH2500 User s Manual 251104-109159 Rev. 061107 User s Record: To provide quality customer service and technical support, it is suggested that you keep the
e 1 0 0 I N S T RUC TION M ANU A L
e 1 0 0 I N S T RUC TION M ANU A L The Empire Digital Level Accuracy, Readability, Durability one FEATURES: Easy to read back light Display reads right side up even if the level is upside down Audio beep