Validation Methodology to Allow Simulated Peak Reduction and Energy Performance Analysis of Residential Building Envelope with Phase Change Materials
|
|
|
- Geraldine Wood
- 10 years ago
- Views:
Transcription
1 Validation Methodology to Allow Simulated Peak Reduction and Energy Performance Analysis of Residential Building Envelope with Phase Change Materials Preprint P.C. Tabares-Velasco, C. Christensen, and M. Bianchi Presented at the 2012 ASHRAE Annual Conference San Antonio, Texas June 23-27, 2012 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Conference Paper NREL/CP August 2012 Contract No. DE-AC36-08GO28308
2 NOTICE The submitted manuscript has been offered by an employee of the Alliance for Sustainable Energy, LLC (Alliance), a contractor of the US Government under Contract No. DE-AC36-08GO Accordingly, the US Government and Alliance retain a nonexclusive royalty-free license to publish or reproduce the published form of this contribution, or allow others to do so, for US Government purposes. This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof. Available electronically at Available for a processing fee to U.S. Department of Energy and its contractors, in paper, from: U.S. Department of Energy Office of Scientific and Technical Information P.O. Box 62 Oak Ridge, TN phone: fax: mailto:[email protected] Available for sale to the public, in paper, from: U.S. Department of Commerce National Technical Information Service 5285 Port Royal Road Springfield, VA phone: fax: [email protected] online ordering: Cover Photos: (left to right) PIX 16416, PIX 17423, PIX 16560, PIX 17613, PIX 17436, PIX Printed on paper containing at least 50% wastepaper, including 10% post consumer waste.
3 Validation Methodology to Allow Simulated Peak Reduction and Energy Performance Analysis of Residential Building Envelope with Phase Change Materials Paulo Cesar Tabares-Velasco, PhD Craig Christensen Marcus V. A. Bianchi, PhD, PE Associate Member ASHRAE Member ASHRAE ABSTRACT Phase change materials (PCMs) represent a potential technology to reduce peak loads and HVAC energy consumption in residential buildings. This paper summarizes NREL s efforts to obtain accurate energy simulations when PCMs are modeled in residential buildings: the overall methodology to verify and validate conduction finite difference (CondFD) and PCM algorithms in EnergyPlus is presented in this study. It also shows preliminary results of three residential building enclosure technologies containing PCM: PCM-enhanced insulation, PCMimpregnated drywall, and thin PCM layers. The results are compared based on predicted peak reduction and energy savings using the PCM and CondFD algorithms in EnergyPlus. INTRODUCTION Energy can be stored in buildings by sensible, latent, or chemical means. From these three types, latent storage using phase change materials (PCMs) has been the focus of multiple studies and considerations because it may be capable of greater thermal energy storage per volume than sensible storage. Several PCMs are commercially available that vary in type (salts, paraffins, fatty acids), encapsulation technology (micro and macro encapsulation), and melting temperatures (covering a range that is useful for building wallboard and enclosure applications, o F [18-40 o C]). Previous PCM studies have shown that there are important benefits related to thermal comfort, energy savings, and the potential for HVAC downsizing when thermal storage is added into buildings (Zhu et al. 2009). These benefits are achieved through the appropriate design and selection of PCMs, because PCMs can reduce temperature fluctuations and shift heating and cooling demand (Khudhair and Farid 2004). Early building energy simulations efforts in this area focused on wallboards impregnated with PCMs (Drake 1987; Peippo et al. 1991; Solomon 1979; Stovall and Tomlinson 1995; Tomlinson and Heberle 1990). Later building simulation studies focused on various PCM applications: PCM impregnated in fiber insulation (Kosny et al. 2010a; Shrestha et al. 2011), macro-encapsulated PCMs in walls (Kosny et al. 2010b), and floor heating systems that utilize shape-stabilized PCMs (Lin et al. 2004; Zhang et al. 2006). PCM energy modeling is a complex task that requires sophisticated building energy simulation programs that can accurately simulate PCMs for different applications in homes: attics, walls, and floors. There have also been efforts to benchmark PCM models with whole-building field data using a house with PCM distributed in the attic and wall insulation (Shrestha et al. 2011). However, the ability to reproduce the experimental results in EnergyPlus was limited because of issues with the software code in multi-zone buildings. Paulo Cesar Tabares-Velasco is a Postdoctoral Researcher, Residential Buildings Research Group, National Renewable Energy Laboratory (NREL). Craig Christensen is Principal Engineer, Residential Buildings Research Group, NREL. Marcus Bianchi was a Senior Engineer, Residential Buildings Research Group, NREL. He presently is Building Science Program Leader at Owens Corning. 1
4 However, the ability to reproduce the experimental results in EnergyPlus was limited because of issues with the software code in multi-zone buildings. The objective of this study was to validate the EnergyPlus conduction finite difference (CondFD) algorithm for multizone buildings and to investigate the potential benefits when PCMs are installed in homes. This study also summarizes NREL validation efforts to conduct accurate energy simulations with PCMs, as this is part of an ongoing investigation with the overall goal of optimizing PCMs in buildings. VERIFICATION AND VALIDATION METHODOLOGY EnergyPlus can simulate PCMs only with the CondFD solution algorithm. CondFD discretizes walls, floors, and ceilings into several nodes and uses an implicit finite difference scheme to numerically solve the appropriate heat transfer equations (EnergyPlus 2011). To model PCMs, the CondFD method is coupled with an enthalpy-temperature function that users input to account for enthalpy changes during phase change. This function is used to develop an equivalent specific heat at each time step that inputs the CondFD equations (EnergyPlus 2011). Thus, accurate modeling of PCMs requires validation of the PCM and CondFD algorithms. This validation work was completed at NREL following ASHRAE Standard 140 and NREL validation methodologies, which consist of analytical verification, comparative testing, and empirical validation (Judkoff and Neymark 2006). Overall, the process is divided in two levels (wall or building) and the two algorithms (CondFD and PCM), as shown in Table 1. The wall-level tests were detailed tests that focused on a single wall subjected to particular boundary conditions on both sides for a relatively short period of time. Thus, the wall level validation tested the ability of only the specific CondFD and PCM algorithms to accurately model building envelope applications. The wall-level tests for CondFD and PCM algorithms were presented in previous studies (Tabares-Velasco and Griffith 2012; Tabares-Velasco et al. 2012). This was an important step, but it did not guarantee that the algorithms would work with more realistic situations and different HVAC systems. Verification/ Validation Level Wall Building Table 1. Verification and Validation CondFD Analytical: Variable k Composite wall Const heat flux (2) Periodic BC Symmetry Comparative: H7.3 transient variable k H7.3 transient multilayer wall Comparative: ASHRAE 140 Case 600 BEopt 1 retrofit house BEopt new house PCM Analytical: Stefan Problem Comparative: Heating 7.3 Empirical: DuPont Hotbox Evaluation: ASHRAE 140 Case 600 BEopt retrofit house BEopt new house In contrast, the whole-house tests of this study focus on an entire building, considering interactions between the weather, building envelope, HVAC, and internal loads for periods of time that vary from a few days to a year. Building-level validation tests single-zone or multi-zone houses and is mainly a comparison between conduction transfer functions (CTFs) and CondFD. Building-level verification compares hourly surface temperatures, average zone temperatures, hourly heating 1 Building Energy Optimization (BEopt) is residential building energy optimization software. See 2
5 and cooling energy, and total heating and cooling energy between CondFD and CTFs. A building-level evaluation of the PCM algorithm is presented in another study (Tabares-Velasco et al. 2012). However, PCM results could not be compared to the CTF 2 results because PCMs cannot be modeled using the CTF algorithm. Thus, this work was called evaluation instead of verification (see Table 1). Nevertheless, the evaluation compared the run time and number of iterations required for CondFD to converge for various PCM applications as a measure to confirm models were converging without previous stability problems detected. All simulations had similar run times and required similar numbers of iterations, which was consistent with the wall-level verification for PCMs (Tabares-Velasco et al. 2012). Overall the PCM model is now validated after wall-level validation and building-level evaluation. Thus, this paper presents the comparative verification for CondFD using the whole-building test (lower-left quadrant of Table 1). WHOLE-BUILDING COMPARATIVE VERIFICATION OF CONDFD The comparative building level verification for CondFD without PCMs consisted of: 1. ASHRAE Standard 140 Case 600: a simple single-zone building with lightweight construction (ASHRAE 2004). 2. BEopt retrofit house: a one-story, 1,280-ft 2 (120-m 2 ), 1960s-era house with three bedrooms, two bathrooms, and an unconditioned attic modeled in six of the eight original U.S. cities considered in previous retrofit analysis efforts (Polly et al. 2011). 3. BEopt new house: a two-story, 2500-ft 2 (231-m 2 ) house with three bedrooms, two bathrooms, a garage, and an unconditioned attic. The new homes were developed in BEopt according to the 2010 Building America Simulation Protocols, which represent a house built according to the 2009 International Energy Conservation Code (IECC) and federal appliance standards in effect as of January 1, 2010 (Hendron and Engebrecht 2010). More details about the house can be found in the literature (Casey and Booten 2011). BEopt houses were created in BEopt version 1.1; the simulation files (idf) were later modified outside of BEopt to allow comparison between CTF and CondFD. The foundation type of the homes varied according to location, as shown in Figure 1. The verification was done using 1-minute time step (shortest allowed in EnergyPlus; default time step for CTFs is 10 minutes) for CondFD as well as for CTFs and other time steps. We have found that CondFD users should use time steps 3 minutes or shorter. However, future research is necessary to address time step sensitivity more fully. The retrofit and new house validation consisted of three-day summer and winter tests (instead of full annual tests) to reduce the run times. Initial findings from this procedure helped identify multiple problems in EnergyPlus that resulted in average energy use differences of up to 30%. The problems were related to the modeling of 1) walls between zones (e.g., walls between living space and garage/attic) and 2) adiabatic walls and massless walls. In both cases, CondFD was not correctly distinguished between external and internal boundary conditions when adiabatic walls were presented (among other minor bugs). We worked with the EnergyPlus development team to resolve the issues; the next release EnergyPlus in 2012 (version 7.1) will have a more reliable model. The corrected EnergyPlus model was used to conduct all simulations presented in this study. Figure 1 shows the cooling energy calculated using the CTF and CondFD algorithms for the BEopt new houses. The green line represents the percent difference (on the right axis) between CTF and CondFD; all were less than 0.4%. Additional annual simulations for Chicago and Phoenix houses showed that the annual percent energy differences were even smaller than those calculated by the three-day tests. All tests showed very close agreement between CTF and CondFD. 2 The default CTF solution algorithm in EnergyPlus cannot simulate materials with variable properties such as PCMs (EnergyPlus 2011). 3
6 150 3-DAY Cooling Energy Use CTF CondFD %Diff 0.4% Cooling Energy (kwh) Basement Crawlspace Slab Chicago Seattle Atlanta LA Houston Phoenix Location Figure 1. Three-Day Cooling Energy use calculated with EnergyPlus using the CTF and CondFD algorithms for BEopt new houses without PCMs. The green line represents differences between the algorithms, with values displayed on the right-y axis. DETAILED DIAGNOSTICS AVAILABLE WITH WHOLE BUILDING ANALYSIS FOR PCM SYSTEMS WITH VALIDATED PCM MODEL Once the CondFD and PCM algorithms were validated, a similar house to the BEopt new house was analyzed in more detail in EnergyPlus for the Phoenix location and weather data using 2010 Building America Simulation Protocols (Hendron and Engebrecht 2010). Thus, the house has natural ventilation as long as it can meet the cooling load and the indoor temperature stays above the heating set point. Cooling and heating set points were 76 o F (24.4 o C) and 71 o F (21.7 o C), respectively, with a COP of 3.9. The intent of this analysis is to show how the whole-building analysis of a PCM system can produce information that is useful for selecting the type, amount, and location of PCMs for improved energy performance. However, it is not the intention of this study to perform a parametric analysis of PCMs or show the potential energy savings from PCMs. The original building model generated in BEopt was modified to accommodate PCMs: walls and attic were assumed to be studless and trussless. This assumption was necessary, as BEopt cannot model PCMs at this time. BEopt calculates equivalent material layers for stud and cavity using the parallel path method; therefore, there is currently no easy way to correctly model PCM materials in parallel with other materials using BEopt. These assumptions resulted in R- values for the studless wall of RSI-2.7 (RIP-15.3) and RSI-6.7 (RIP-40) for the trussless attic. Table 2 shows the properties of the PCM aggregate materials analyzed in this study: PCM distributed in insulation, PCM distributed in drywall, and concentrated PCM layer. These three cases represent products that are already on the market or that have been previously investigated (Kedl 1990; Kosny et al. 2010a; Kosny et al. 2010b). From these three materials, concentrated PCM has more thermal storage capacity (in Btu/ft 2 or kj/m 2 ), as it is the only concentrated application analyzed in this study. Figure 2 shows predicted monthly cooling electric energy reduction for the analyzed PCM applications. All monthly savings were divided by the annual energy use for the building without PCMs. The PCM applications analyzed are: PCM distributed in drywall on the ceiling (DW_Ceil) and walls (DW_Walls), PCM distributed in wall insulation (Walls), PCM concentrated at the middle of the wall cavity insulation (RCRWall) and a combination of RCRWall with PCM distributed in Drywall (RCRWall-DW). The last application was selected because the two PCM applications showed the best performance during cooling season. Thus, it is added here to show the potential savings when multiple PCM applications are used within a single building. For this particular case, the combination of RCRWall with RCRWall-DW achieved the highest annual percentage savings, which were around 4% or approximately 716 kbtu (210 kwh). However, more in-depth parametric analysis is needed before any conclusions can be made, as this study did not analyze several melting temperatures or storage capacities to optimize energy and/or peak load savings. 0.3% 0.2% 0.1% 0.0% -0.1% Difference (%) 4
7 Table 2. Properties of PCM Strategies Analyzed Properties PCM Distributed PCM Distributed Concentrated PCM Insulation Drywall Layer % Weight of PCM in Wall Layer 40% 30% 100% Equivalent Latent Heat 9.5 Btu/lb (68 kj/kg) 14 Btu/lb (33 kj/kg) 56 Btu/lb (130 kj/kg) Melting Temperature Range o F ( o C) o F ( o C) o F ( o C) Thermal Conductivity Btu in/(h ft R) 1.595Btu in/(h ft R) Btu in/(h ft R) ( W/m K) (0.23 W/m K) (0.16 W/m K) Density 4.4 lb/ft 3 (70 kg/m 3 ) 62.4 lb/ft 3 (1000 kg/m 3 ) 53.1 lb/ft 3 (850 kg/m 3 ) Specific Heat 0.229Btu/lb R Btu/lb R Btu/lb R (960 J/kg K) (1400 J/kg K) (2500 J/kg K) Thickness Wall 3.5in (0.089m) 0.5in (0.0127m) 0.2in (0.005m) Walls Latent Storage 37.2 Btu/ft 2 (423 kj/m 2 ) 36.8 Btu/ft 2 (420 kj/m 2 ) 48.6 Btu/ft 2 (550 kj/m 2 ) Amount of PCM 0.5 lb/ft 2 (2.5 kg/m 2 ) 0.8 lb/ft 2 (3.8kg/m 2 ) 0.9 lb/ft 2 (4.2kg/m 2 ) Energy Savings (Month savings / year energy use) DW_Ceil Walls RCRWall Drywall DW_Walls RCRWall_DW 0.8% % % % % % % % 5 0.0% 0 Mar Apr May Jun Jul Aug Sep Oct Nov Figure 2. Predicted cooling energy savings for PCM strategies. It is also interesting to see the seasonal performance variability of the PCM applications: all PCM-drywall applications performed the best during the swing seasons; the system with the concentrated application offered more continuous benefits. Moreover, the results show only small differences between installing the PCM drywall in the walls and the ceiling (DW_Walls and. DW_Ceil). Figure 3 shows the peak cooling reduction benefits for the same house and PCM applications. Similar to energy savings, the PCM application with the highest reduction was the combination of RCRWall and RCRWall-DW. However, the highest peak reduction was achieved during April and May, months when electricity peak demand typically is not a concern, as July and August are typically the months when local utilities struggle to meet the cooling demand. Figure 4 shows the predicted hourly cooling energy savings from four of the six PCM applications analyzed for four sunny days in April with diurnal temperature variations of o F (15-35 o C). Energy savings from installing PCMs are shown in the left Y-axis. The cooling energy use of the house without PCM (CoolingEnerg) is shown in the right Y-axis as a reference. During these days, PCM savings peak at the same time when the cooling energy use peaks. This is due to the large temperature variation that went below and above the melting temperature range of the PCMs. Thus, allowing them to melt and solidify daily. Day-to-day variations are due to weather change: outdoor air temperatures were slightly warmer for the last two days. Overall PCM locations have an important role that need to be considered when designing PCMs. Energy Savings (kwh) 5
8 DW_Ceil Walls RCRWall Drywall DW_Walls RCRWall_DW Peak Reduction (Month energy ) 8% 6% 4% 2% 0% -2% -4% Mar Apr May Jun Jul Aug Sep Oct Nov Figure 3. Predicted peak cooling reduction from PCM strategies. Cooling Energy Savings and Use: 4/05-4/ Peak Reduction (kw) Cooling Energy Savings (kwh) RCRWall Walls DW_walls RCRWall_DW CoolingEner (kwh) 1.0 Peak Demand Time (hrs) Figure 4. Predicted hourly energy savings from PCM wall applications in April in Phoenix. Right Y-axis shows hourly energy use for house without PCMs (CoolingEner). Figure 5 shows the predicted hourly cooling energy savings for the same PCM applications shown in Figure 4, but for four days in July with diurnal temperature variations of o F (30-45 o C). During these days, PCM energy savings peak earlier than the peak cooling demand and overall energy savings are smaller than in April. This is due to the mismatch between the thermal properties for the selected PCMs and the outdoor temperatures during the warm summer weather; the PCMs selected melt between o F (28-30 o C), so the outdoor temperature is above the melting range for most of the four-day period. Thus, the chosen PCMs were not able to melt and solidify daily, which limited their ability to store additional heat. Higher savings could be obtained if a PCM with higher melting temperature and/or storage capacity is selected. Overall, these results show strong seasonal variations for energy savings and peak load reductions, which suggests that the characteristics of optimal PCM solutions depend strongly on the user s energy goals. Figure 6 shows predicted monthly heating energy savings for the analyzed PCM applications. For the heating season, the PCM application with drywall in the interior of the house obtained the best performance, with 25% predicted annual savings. These savings might be improved if PCM properties are optimized in future studies. Similar to the cooling case, there were only small changes between PCM drywall installed in the ceiling and walls. For this particular climate and building for these selected PCMs, percent heating energy savings were higher than percent cooling energy savings. Despite the fact that annual onsite heating energy use represented about 1/2 of the total cooling onsite energy, the predicted Cooling Energy Use (kwh) 6
9 absolute heating energy savings were almost 3 times higher than cooling energy savings for this particular house, climate, and PCM selection. RCRWall Walls DW_walls RCRWall_DW CoolingEner (kwh) 0.30 Peak Demand Time (hrs) 0 Figure 5. Predicted hourly energy savings from PCM wall applications in July in Phoenix. Right Y-axis shows hourly energy use for house without PCMs (CoolingEner). CONCLUSION Cooling Energy Savings (kwh) Enenrgy Savings (Month savings/ year energy use) Cooling Energy Savings and Use: 7/16-7/19 DW_Ceil Walls RCRWall Drywall_All DW_Walls RCRWall-DW a 8% 180 7% 160 6% 140 5% 120 4% % 60 2% 40 1% 20 0% 0 Jan Feb Mar Apr Nov Dec Figure 6. Predicted heating energy savings from PCM strategies. This paper summarizes the approach to validate the CondFD and PCM algorithms in EnergyPlus. This study also shows how the whole-building analysis of a PCM system can produce information that is useful for selecting the type, amount, and location of PCMs for improved energy performance. This application of whole-building analysis is demonstrated for three residential building envelope technologies containing specific PCMs: PCM distributed in insulation, PCM distributed in drywall, and concentrated PCM layer between insulation in the walls. These technologies are compared based on peak reduction and energy savings using the CondFD algorithm in EnergyPlus. Preliminary results suggest that considerable annual energy savings could be achieved using PCMs in residential buildings, but that careful design is needed to optimize PCM solutions according to the specific user goals for peak demand and energy use reductions. Future research will include more detailed parametric analyses to optimize PCM wall strategies as well as analyzing cooling and heating control strategies. Energy Savings (kwh) Cooling Energy Use (kwh) 7
10 ACKNOWLEDGMENTS This work was supported by the U.S. Department of Energy under Contract No. DE-AC36-08-GO28308 with the National Renewable Energy Laboratory. The authors would like to thank Marc LaFrance, for supporting research on phase change materials. The authors would like to thank Ben Polly of NREL for his critical reviews and Brent Griffith and Linda Lawrie from the EnergyPlus development team for their technical support. REFERENCES ASHRAE ANSI/ASHRAE Standard Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Atlanta, GA, ASHRAE: 151. Casey, S. and C. Booten Energy Savings Measure Packages: New Homes. Golden, National Renewable Energy Laboratory: 205. Drake, J. B A study of the optima; transition temperature of PCM wallboard for solar energy storage, Oak Ridge National Laboratory. ORNL\TM EnergyPlus EnergyPlus Engineering Reference: The Reference to EnergyPlus Calculations, Ernest Orlando Lawrence Berkeley National Laboratory: Hendron, R. and C. Engebrecht Building America House Simulation Protocols Golden, CO, National Renewable Energy Laboratory: 80. Judkoff, R. and J. Neymark Model Validation and Testing: The Methodological Foundation of ASHRAE Standard 140; Preprint. Kedl, R. J Conventional wallboard with latent heat storage for passive solar applications. Khudhair, A. M. and M. M. Farid A review on energy conservation in building applications with thermal storage by latent heat using phase change materials. Energy Conversion and Management 45(2): Kosny, J., S. Shrestha, D. Yarbrough, P. Childs, W. Miller, M. Bianchi, J. Smith, T. Fellinger, E. Kossecka and E. Lee. 2010a. Theoretical and Experimental Thermal Performance Analysis of Building Shell Components Containing Blown Fiberglass Insulation Enhanced with Phase-Change Materials (PCM). Thermal Performance of the Exterior Envelopes of Whole Buildings XI International Conference. Clearwater Beach, Florida: 13. Kosny, J., S. Shrestha, T. Stovall and D. Yarbrough. 2010b. Theoretical and Experimental Thermal Performance Analysis of Complex Thermal Storage Membrane Containing Bio-base Phase Change Material (PCM). Thermal Performance of The Exterior Envelopes of Whole Buildings XI International Conference. Clearwater Beach, FL: 11. Lin, K., Y. Zhang, X. Xu, H Di, R. Yang, and P Qin Modeling and simulation of under-floor electric heating system with shape-stabilized PCM plates. Building and Environment 39(12): Peippo, K., P. Kauranen, and P.D. Lund Multicomponent PCM wall optimized for passive solar heating. Energy and Buildings 17(4): Polly, B., M. Gestwick, M. Bianchi, R. Anderson, S. Horowitz, C. Christensen, and R Judkoff A Method for Determining Optimal Residential Energy Efficiency Retrofit Packages NREL Technical Report DOE/GO Golden, CO, National Renewable Energy Laboratory: 79. Shrestha, S., W. Miller, T. Stovall, A. Desjarlais, K. Childs, W. Porter, M. Bhandari and S Coley Modeling PCM- Enhanced Insulation System and Benchmarking EnergyPlus against Controlled Data Field Building Simulation 2011: 12th Conference of International Building Performance Simulation Association Sidney. Solomon, A. D Design criteria in PCM wall thermal storage. Energy 4(4): Stovall, T. K. and J. J. Tomlinson What are the potential benefits of including latent storage in common wallboard? Journal of Solar Energy Engineering, Transactions of the ASME 117(4): Tabares-Velasco, P. C., C. Christensen, M. Bianchi Verification and Validation of EnergyPlus Phase Change Material Model for Opaque Wall Assemblies. Building and Environment DOI: /j.buildenv Tabares-Velasco, P. C. and B. Griffith Diagnostic test cases for verifying surface heat transfer algorithms and boundary conditions in building energy simulation programs. Journal of Building Performance Simulation: DOI: / Tomlinson, J. J. and D. D. Heberle Analysis of wallboard containing a phase change material, Reno, NV, Publ by IEEE. Zhang, Y., K. Lin, Q. Zhang and H Di Preparation, thermal performance and application of shape-stabilized PCM in energy efficient buildings. Energy and Buildings 38(10): Zhu, N., Z. Ma, S Wang Dynamic characteristics and energy performance of buildings using phase change materials: A review. Energy Conversion and Management 50(12):
Early Fuel Cell Market Deployments: ARRA and Combined (IAA, DLA, ARRA)
Technical Report NREL/TP-56-588 January 3 Early Fuel Cell Market Deployments: ARRA and Combined (IAA, DLA, ARRA) Quarter 3 Composite Data Products Jennifer Kurtz, Keith Wipke, Sam Sprik, Todd Ramsden,
THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS
THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS James L. Hoff, VP of Research Center for Environmental Innovation in Roofing Tools and Models Tools require models
Small PV Systems Performance Evaluation at NREL's Outdoor Test Facility Using the PVUSA Power Rating Method
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Small PV Systems Performance
NREL Job Task Analysis: Crew Leader
NREL Job Task Analysis: Crew Leader Chuck Kurnik National Renewable Energy Laboratory Cynthia Woodley Professional Testing Inc. NREL is a national laboratory of the U.S. Department of Energy, Office of
Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls
PCA R&D Serial No. 415 Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls by John Gajda and Martha VanGeem 000 Portland Cement Association KEYWORDS Concrete,
Regional Field Verification Operational Results from Four Small Wind Turbines in the Pacific Northwest
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Regional Field Verification Operational
THERMAL STORAGE WITH PCM VS. THERMAL INSULATION IN WARM AND HOT CLIMATES
THERMAL STORAGE WITH PCM VS. THERMAL INSULATION IN WARM AND HOT CLIMATES G. C HRISTOPH SPAEH, PE, LEED BD+C SUTTON KENNERLY & ASSOC., INC. 300 Pomona Dr., Greensboro, NC 27403 Phone: 336-855-0993 Fax:
PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation
PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation INTRODUCTION As the use of spray polyurethane foam (SPF) insulation is increasing in both
Residential HVAC System Sizing
Residential HVAC System Sizing William P. Goss University of Massachusetts, Amherst, Massachusetts, USA Corresponding email: [email protected] SUMMARY Heating, ventilating and air-conditioning (HVAC)
Strategy Guideline: HVAC Equipment Sizing
Strategy Guideline: HVAC Equipment Sizing Arlan Burdick IBACOS, Inc. February 2012 This report received minimal editorial review at NREL NOTICE This report was prepared as an account of work sponsored
Market Potential Study for Water Heater Demand Management
Market Potential Study for Water Heater Demand Management Rebecca Farrell Troutfetter, Frontier Associates LLC, Austin, TX INTRODUCTION Water heating represents between 13 and 17 percent of residential
Sensitivity of Forced Air Distribution System Efficiency to Climate, Duct Location, Air Leakage and Insulation
LBNL 43371 Sensitivity of Forced Air Distribution System Efficiency to Climate, Duct Location, Air Leakage and Insulation Iain S. Walker Energy Performance of Buildings Group Indoor Environment Department
Energy Systems Integration
Energy Systems Integration A Convergence of Ideas Ben Kroposki, Bobi Garrett, Stuart Macmillan, Brent Rice, and Connie Komomua National Renewable Energy Laboratory Mark O Malley University College Dublin
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Dept. Building Environment Science &Technologies Politecnico di Milano Italy Research funded
Cost Analysis of Simple Phase Change Material-Enhanced Building Envelopes in Southern U.S. Climates
Cost Analysis of Simple Phase Change Material-Enhanced Building Envelopes in Southern U.S. Climates Jan Kosny, Nitin Shukla, and Ali Fallahi Fraunhofer CSE January 2013 NOTICE This report was prepared
Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates
Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates Arthur Rosenfeld, California Energy Commission Gregory Rosenquist, Lawrence Berkeley National Laboratory C. Keith Rice,
FINAL REPORT LIFE-CYCLE COST STUDY OF A GEOTHERMAL HEAT PUMP SYSTEM BIA OFFICE BLDG., WINNEBAGO, NE
FINAL REPORT LIFE-CYCLE COST STUDY OF A GEOTHERMAL HEAT PUMP SYSTEM BIA OFFICE BLDG., WINNEBAGO, NE February 2006 FINAL REPORT LIFE-CYCLE COST STUDY OF A GEOTHERMAL HEAT PUMP SYSTEM BIA OFFICE BLDG., WINNEBAGO,
Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues
LBNL-6129E ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues Liping Wang, Tianzhen Hong Environmental
A Study of the Energy-Saving Potential of Metal Roofs Incorporating Dynamic Insulation Systems
A Study of the Energy-Saving Potential of Metal Roofs Incorporating Dynamic Insulation Systems Kaushik Biswas, PhD Associate Member ASHRAE Scott Kriner William Miller, PhD Member ASHRAE Gary Manlove ABSTRACT
Drury B. Crawley U.S. Department of Energy Washington, DC 20585 USA
TESTING AND VALIDATION OF A NEW BUILDING ENERGY SIMULATION PROGRAM Michael J. Witte, Robert H. Henninger, and Jason Glazer GARD Analytics, Inc. Park Ridge, IL 668 USA Drury B. Crawley U.S. Department of
Cost Estimation for Materials and Installation of Hot Water Piping Insulation
Cost Estimation for Materials and Installation of Hot Water Piping Insulation Prepared for Pacific Northwest National Laboratory Under Contract Number: 18O9O2 By Gary Klein, Managing Partner Affiliated
Energy Efficiency: Integrated Design and HVAC Systems HEALTHCARE - TOP 5 GREEN BUILDING STRATEGIES
EPA Publication 909-F-07-001 What? Energy use in healthcare facilities is higher than nearly all other building types. With rising energy costs and climate change concerns energy efficiency is financially
EXPERIMENTAL INVESTIGATION OF A BIO-BASED PHASE-CHANGE MATERIAL TO IMPROVE BUILDING ENERGY PERFORMANCE
Proceedings of ASME 2010 4 th International Conference on Energy Sustainability ES2010 May 17-22, 2010 Phoenix, Arizona, USA ES2010-90035 EXPERIMENTAL INVESTIGATION OF A BIO-BASED PHASE-CHANGE MATERIAL
Exploring the Building Energy Impacts of Green Roof Design Decisions - A Modeling Study of Buildings in 4 Distinct Climates
Final version for publication: Exploring the Building Energy Impacts of Green Roof Design Decisions - A Modeling Study of Buildings in 4 Distinct Climates David J. Sailor 1, Timothy B. Elley 2, and Max
Use of Microencapsulated Phase Change Materials in Building Applications
Use of Microencapsulated Phase Change Materials in Building Applications C. Castellón M. Medrano, PhD J. Roca, PhD M. Nogués, PhD A. Castell L.F. Cabeza, PhD ABSTRACT Phase Change Materials (PCMs) have
Residential Duct Systems for New and Retrofit Homes
Residential Duct Systems for New and Retrofit Homes Why it is important to properly design and install high quality, efficient ducted air systems? The efficiency of air distribution systems has been found
Diego Ibarra Christoph Reinhart Harvard Graduate School of Design
Building Performance Simulation for Designers - Energy DesignBuilder // EnergyPlus Tutorial #2 Load Schedules GEOMETRY LOADS RESULTS Diego Ibarra Christoph Reinhart Harvard Graduate School of Design OVERVIEW
Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer
Residential HVAC Load Sizing Training October 14, 2015 David Kaiser Green Code Plan Reviewer DCRA - Green Building Division Regulations of green codes including: Green Building Act Green Construction Code
Maximizing the Benefits of Residential Pre-Cooling
Maximizing the Benefits of Residential Pre-Cooling Alea German, Marc Hoeschele and David Springer, Davis Energy Group ABSTRACT Residential air conditioning represents a challenging load for many electric
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating
MICROENCAPSULATED PHASE CHANGE MATERIALS (PCM) FOR BUILDING APPLICATIONS
MICROENCAPSULATED PHASE CHANGE MATERIALS (PCM) FOR BUILDING APPLICATIONS C. Castellón, M. Nogués, J. Roca, M. Medrano, L. F. Cabeza Departament d Informàtica i Eng. Industrial, Universitat de Lleida Pere
Computer Simulations of Edge Effects in a Small-Area Mesa N-P Junction Diode
Computer Simulations of Edge Effects in a Small-Area Mesa N-P Junction Diode Preprint Conference Paper NREL/CP-520-45002 February 2009 J. Appel and B. Sopori National Renewable Energy Laboratory N.M. Ravindra
Energy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
Wind Forecasting stlljectives for Utility Schedule and Energy Traders
NREUCP 500 24680 UC Category: 1210 Wind Forecasting stlljectives for Utility Schedule and Energy Traders Marc N. Schwartz National Renewable Energy Laboratory Bruce H. Bailey A WS Scientific, Inc. Presented
Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.
Codes and High Performance Hot Water Systems Gary Klein Affiliated International Management, LLC 916 549 7080 [email protected] Annual Energy Use for Heating Water Natural Gas Gallons Per Day
Potential of Energy Efficiency and Renewable Energy Savings To Impact Florida s Projected Energy Use in 2014
Potential of Energy Efficiency and Renewable Energy Savings To Impact Florida s Projected Energy Use in 2014 Author Fairey, Philip Publication Number FSEC-RR-58-06 Copyright Copyright Florida Solar Energy
CFD Analysis of Application of Phase Change Material in Automotive Climate Control Systems
CFD Analysis of Application of Phase Change Material in Automotive Climate Control Systems Vijayakumar Nachimuthu 1, Prabhu Mani 2, Muthukumar. P 3 1 Flowxplore, Coimbatore, India., 2 Kathir College of
NILM Applications for the Energy-Efficient Home
NILM Applications for the Energy-Efficient Home D. Christensen, L. Earle, and B. Sparn NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated
Could a European Super Energy Efficient Standard Be Suitable for the U.S.?
Could a European Super Energy Efficient Standard Be Suitable for the U.S.? John Broniek, IBACOS Inc., Pittsburgh, PA Abstract The European Passive House residential energy efficiency standard has produced
Effects of Solar Photovoltaic Panels on Roof Heat Transfer
Effects of Solar Photovoltaic Panels on Roof Heat Transfer A. Dominguez, J. Kleissl, & M. Samady, Univ of California, San Diego J. C. Luvall, NASA, Marshall Space Flight Center Building Heating, Ventilation
Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving
346 2nd PALENC Conference and 28th AIVC Conference on Building Low Energy Cooling and Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving S. Ferrari Politecnico
RELEASE NOTES EG USA 3.0.0
RELEASE NOTES EG USA 3.0.0 Version 3.0 has a multitude of changes from version 2.8.05. One of the major changes is the ability to break up a home into Blocks with different HVAC systems. This includes
IECC Compliance Guide for Homes in Virginia
IECC Compliance Guide for Homes in Virginia Amended Version of 2012 International Energy Conservation Code July 14, 2014 Climate Zone Since the entire state of Virginia falls in the IECC Climate Zone 4,
Rate Analysis of Two Photovoltaic Systems in San Diego
Rate Analysis of Two Photovoltaic Systems in San Diego Technical Report NREL/TP-6A2-43537 July 2009 Elizabeth Doris, Sean Ong, and Otto Van Geet Rate Analysis of Two Photovoltaic Systems in San Diego Technical
A New Empirical Relationship between Thrust Coefficient and Induction Factor for the Turbulent Windmill State
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy A New Empirical Relationship
Building Energy Codes 101 October 23, 2013. Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance
Building Energy Codes 101 October 23, 2013 Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance OVERVIEW 1. Introduction 2. Energy Code Development 3. Adoption Process 4. Elements
Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Kansas City, Missouri
PNNL-20699 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Kansas City, Missouri
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
Laboratory Test Report for Fujitsu 12RLS and Mitsubishi FE12NA Mini-Split Heat Pumps
Laboratory Test Report for Fujitsu 12RLS and Mitsubishi FE12NA Mini-Split Heat Pumps Jon Winkler, Ph.D. September 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the
Measurement of BET Surface Area on Silica Nanosprings
PNNL-17648 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Measurement of BET Surface Area on Silica Nanosprings AJ Karkamkar September 2008 DISCLAIMER This report was prepared
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY Benson Kwong, CVS, PE, CEM, LEED AP, CCE envergie consulting, LLC Biography Benson Kwong is an independent consultant providing
Energy Savings in High-Rise Buildings Using High-Reflective Coatings
Energy Savings in High-Rise Buildings Using High-Reflective Coatings Executive Summary: Nevertheless, the simulation analyses showed that when designing a building for low energy consumption, even in cold
Moisture Content in Insulated Basement Walls
Moisture Content in Insulated Basement Walls Peter Blom,PhD, SINTEF Building and Infrastructure; [email protected], www.sintef.no/byggforsk Sverre B. Holøs M.Sc. SINTEF Building and Infrastructure;
COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*
COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) 2 Fixed Rates Variable Rates FIXED RATES OF THE PAST 25 YEARS AVERAGE RESIDENTIAL MORTGAGE LENDING RATE - 5 YEAR* (Per cent) Year Jan Feb Mar Apr May Jun
COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*
COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) 2 Fixed Rates Variable Rates FIXED RATES OF THE PAST 25 YEARS AVERAGE RESIDENTIAL MORTGAGE LENDING RATE - 5 YEAR* (Per cent) Year Jan Feb Mar Apr May Jun
Software Development for Cooling Load Estimation by CLTD Method
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN: 2278-1684Volume 3, Issue 6 (Nov. - Dec. 2012), PP 01-06 Software Development for Cooling Load Estimation by CLTD Method Tousif Ahmed Department
Ducts in the Attic? What Were They Thinking?
Ducts in the Attic? What Were They Thinking? Preprint Conference Paper NREL/CP-550-48163 August 2010 David Roberts and Jon Winkler National Renewable Energy Laboratory Presented at ACEEE Summer Study Pacific
Passive Solar Design and Concepts
Passive Solar Design and Concepts Daylighting 1 Passive Solar Heating Good architecture? The judicious use of south glazing coupled with appropriate shading and thermal mass. Summer Winter Passive solar
Introduction to Energy Codes & Green Building Programs
Introduction to Energy Codes & Green Building Programs David Neiger B.S. Arch, LEED AP Homes, Certified HERS Rater Principal Populus Sustainable Design Consulting Why green homes? The Building Sector:
ENERGY STAR Data Verification Checklist
ENERGY STAR Data Verification Checklist 86 ENERGY STAR Score 1 Sample Property Primary Function: Office Gross Floor Area (ft²): 200,000 Built: 1980 For Year Ending: 04/30/2013 Date Generated: 06/28/2013
Technical Support for ENERGY STAR Windows Version 6.0 Specification Revision. Gregory K. Homan, Christian Kohler, Emily Zachery* and Dariush Arasteh
Technical Support for ENERGY STAR Windows Version 6.0 Specification Revision Gregory K. Homan, Christian Kohler, Emily Zachery* and Dariush Arasteh Lawrence Berkeley National Laboratory 1 Cyclotron Road
Mississippi. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC
BUILDING TECHNOLOGIES PROGRAM Mississippi Energy and Cost Savings for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC 1 2009 AND 2012 IECC AS COMPARED TO THE 2006 IECC
Simulations of Sizing and Comfort Improvements for Residential Forced-Air Heating and Cooling Systems
Simulations of Sizing and Comfort Improvements for Residential Forced-Air Heating and Cooling Systems May 2002 Walker, I., Degenetais, G. and Siegel, J. Energy Performance of Buildings Group Lawrence Berkeley
Comparison of Building Energy Modeling Programs: Building Loads
LBNL-6034E ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Comparison of Building Energy Modeling Programs: Building Loads Dandan Zhu 1, Tianzhen Hong 2, Da Yan 1, Chuang Wang 1 1 Tsinghua University,
research highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
HVAC Calculations and Duct Sizing
PDH Course M199 HVAC Calculations and Duct Sizing Gary D. Beckfeld, M.S.E., P.E. 2007 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com An
Energy Analysis for Internal and External Window Film Applications for Existing Homes in Florida
Energy & Environmental Solutions Energy Analysis for Internal and External Window Film Applications for Existing Homes in Florida PREPARED FOR: INTERNATIONAL WINDOW FILM ASSOCIATION P.O. BOX 3871 MARTINSVILLE,
Investigation into the energy consumption of a data center with a thermosyphon heat exchanger
Article Mechanical Engineering July 2011 Vol.56 No.20: 2185 2190 doi: 10.1007/s11434-011-4500-5 SPECIAL TOPICS: Investigation into the energy consumption of a data center with a thermosyphon heat exchanger
Heat and cold storage with PCM
Harald Mehling Luisa F. Cabeza Heat and cold storage with PCM An up to date introduction into basics and applications With 208 Figures and 28 Tables 4y Springer Contents 1 Basic thermodynamics of thermal
Design issues For Net Zero Energy Buildings. Laura Aelenei 26 de Junho de 2012
Design issues For Net Zero Energy Buildings Laura Aelenei 26 de Junho de Summary 1.Context Building regulation/policy requirements Scientific advancements 2. Design issues for NZEB General ideas Solar
Models and Methods in Applied Sciences
Energy consumption and energy saving in Malaysian office buildings S.Sadrzadehrafiei, K.Sopian S.Mat, C.Lim Solar Energy Research Institute University Kebangsaan Malaysia 43600, Bangi, Malaysia [email protected],
Heating Load Calculation
Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of
Quality of Building Performance Simulation Predictions - Quality Assurance
Quality of Building Performance Simulation Predictions - Quality Assurance Overview what do we mean by QA? quality assuring the tools what about the user? Quality Assurance (QA)? QA is all about developing
AT&T Global Network Client for Windows Product Support Matrix January 29, 2015
AT&T Global Network Client for Windows Product Support Matrix January 29, 2015 Product Support Matrix Following is the Product Support Matrix for the AT&T Global Network Client. See the AT&T Global Network
Low temperature solar assisted (heating) system based on slurry PCM
ANNEX 59 - High emperature Cooling & Low emperature Heating in Buildings Riqualificazione di edifici esistenti con elevati standard energetici: metodi e tecnologie ENEA - Via G. Romano 41, 00196 Roma -
Sea Water Heat Pump Project
Sea Water Heat Pump Project Alaska SeaLife Center, Seward, AK Presenter: Andy Baker, PE, YourCleanEnergy LLC Also Present is ASLC Operations Manager: Darryl Schaefermeyer ACEP Rural Energy Conference Forum
Elastomer Compatibility Testing of Renewable Diesel Fuels
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Elastomer Compatibility Testing
System Advisor Model, SAM 2014.1.14: General Description
System Advisor Model, SAM 2014.1.14: General Description Nate Blair, Aron P. Dobos, Janine Freeman, Ty Neises, and Michael Wagner National Renewable Energy Laboratory Tom Ferguson, Paul Gilman, and Steven
Whole House Dehumidification for Occupant Comfort and Energy Savings
Downloaded from www.rsrews.com. Since 1968, RS Andrews has proudly served Atlanta's Heating, Air Conditioning & Plumbing Needs. Whole House Dehumidification for Occupant Comfort Energy Savings June 2009
Strategy Guideline: Accurate Heating and Cooling Load Calculations
Strategy Guideline: Accurate Heating and Cooling Load Calculations Arlan Burdick IBACOS, Inc. June 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United States
Comfort Conditioning & Indoor Air Quality
This article was published in ASHRAE Journal, May 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Reprinted here by permission from ASHRAE at www.newellinstruments.com.
Advanced Strategy Guideline: Air Distribution Basics and Duct Design
Advanced Strategy Guideline: Air Distribution Basics and Duct Design Arlan Burdick IBACOS, Inc. December 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
Case Studies: Infrared Heating in Industrial Applications
Case Studies: Infrared Heating in Industrial Applications Chao Chen, Puget Sound Energy ABSTRACT Puget Sound Energy (PSE) is a utility which serves more than one million electric customers and over 700,000