CLARiiON Performance Monitoring Scripting
|
|
|
- Amelia Cross
- 10 years ago
- Views:
Transcription
1 CLARiiON Performance Monitoring Scripting EMC Proven Professional Knowledge Sharing September, 2007 Derek (Yang) Yu Senior Consultant Bell Canada 1
2 Table of Contents CLARiiON Performance Monitoring Scripting... 1 Abstract... 3 Navisphere Analyzer Overview... 3 CLARiiON Performance Monitoring Requirements... 4 SP performance metrics... 4 LUN performance metrics... 5 DISK performance metrics... 5 Scripting Functional Design... 6 Scripting running environment... 6 Primary functions... 6 Other considerations... 7 Script operation guide... 8 Script Adjustment Considerations... 8 Professional Biography... 9 Reference... 9 Disclaimer: The views, processes or methodologies published in this compilation are those of the author. They do not necessarily reflect EMC Corporation s views, processes or methodologies. 2
3 Abstract We all agree that CLARiiON Navisphere Analyzer is a great performance monitoring tool for CLARiiON array. It gathers storage-system performance statistics and presents them in various types of charts. It helps to identify bottlenecks in the storage-system, but you have to access it through web-based Navisphere manager and view each CLARiiON array separately. Based on a large-scale enterprise s request, we have crafted and implemented a scripted approach that has been well accepted. This CLARiiON performance monitoring solution is based on Navisphere Analyzer. It consists of 3 major functions: Retrieve CLARiiON performance raw data Extract specific SP/LUN/DISK performance metrics Generate a daily CLARiiON performance report Average and Maximum values of all selected CLARiiON performance metrics are provided for a quick at-a-glance overview. Daily CLARiiON performance reports will be kept indefinitely for performance trending analysis. And the raw performance data (NAR files) can be retained for the longer term, in case further investigation or reference by specific time frame is required. It is a centralized monitoring solution, running on a single monitoring server. It can be easily scaled to include multiple CLARiiON arrays at the same or different locations. It can also be expanded to be application aware, i.e. SQL server database, Exchange storage groups and Oracle database, etc. Navisphere Analyzer Overview Navisphere Analyzer works within storage domains that Navisphere Manager administers. It gathers storage-system performance statistics and presents them in an assortment of charts. It illustrates bottlenecks in the storage system. You can install the Analyzer enabler on any storage system you want to analyze. It controls, accumulates, and manages access to SP, LUN and DISK performance information, with new information displacing the old. The stored information spans the previous 26 hours (approximately). You can also use the Analyzer GUI to directly display performance data (in real-time mode) or as a file containing past performance data (in archive mode). It can display real-time and archive file data simultaneously. This article focuses on automating Analyzer performance data collection and extraction. 3
4 Navisphere Analyzer requires the following: 1. Navisphere Manager must be installed and enabled on at least one of the storage systems in the storage system domain you want to analyze. 2. Analyzer must be enabled on the storage system you want to analyze. 3. JRE (Java Runtime Environment) must be on the client from which you run the browser. 4. Enable statistics logging on the CLARiiON Storage system. 5. Enable advanced characteristics on the CLARiiON Storage system. With CLARiiON Flare code Release 12 or later, I/O performance is not affected by enabling or disabling statistics logging on a CLARiiON Storage Processor (SP). The effect is less then 5% even on a high object count array (large number of LUNs). So, data collection has little effect on the CLARiiON system and host visible response times. CLARiiON Performance Monitoring Requirements The Storage Processor (SP) processes all I/Os, host requests, management and maintenance tasks, as well as operations related to replication or migration features. In Navisphere Analyzer, the statistics for an SP are based on the I/O workload from its attached hosts. It reflects the overall performance of CLARiiON storage system. The following Performance Metrics will be monitored for each CLARiiON storage system. A LUN is an abstract object whose performance depends on various factors. The primary consideration is whether a host I/O can be satisfied by the cache. A cache hit does not require disk access; a cache miss requires one or more disk accesses to complete the data request. As the slowest devices in a storage system, disk drives are often responsible for performance-related issues. Therefore, we recommend that you pay close attention to disk drives when analyzing performance problems. SP performance metrics Utilization (%) The percentage of time during which the SP is servicing any request. Total Throughput (I/O/sec) The average number of host requests that are passed through the SP per second, including both read and write requests. Read Throughput (I/O/sec) The average number of host read requests that are passed through the SP per second. Write Throughput (I/O/sec) The average number of host write requests that are passed through the SP per second. 4
5 Read Bandwidth (MB/s) The average amount of host read data in Mbytes that is passed through the SP per second. Write Bandwidth (MB/s) The average amount of host write data in Mbytes that is passed through the SP per second. LUN performance metrics Response Time (ms) The average time, in milliseconds, that a request to a LUN is outstanding, including waiting time. Total Throughput (I/O/sec) The average number of host requests that are passed through the LUN per second, including both read and write requests. Read Throughput (I/O/sec) The average number of host read requests passed through the LUN per second. Write Throughput (I/O/sec) The average number of host write requests passed through the LUN per second. Read Bandwidth (MB/s) The average amount of host read data in Mbytes that is passed through the LUN per second. Write Bandwidth (MB/s) The average amount of host write data in Mbytes that is passed through the LUN per second. Average Busy Queue Length The average number of outstanding requests when the LUN was busy. This does not include idle time. Utilization (%) The fraction of an observation period during which a LUN has any outstanding requests. DISK performance metrics Utilization (%) The percentage of time that the disk is servicing requests. Response Time (ms) The average time, in milliseconds, that it takes for one request to pass through the disk, including any waiting time. 5
6 Total Throughput (I/O/sec) The average number of requests to the disk on a per second basis. Total throughput includes both read and write requests. Read Throughput (I/O/sec) The average number of read requests to the disk per second. Write Throughput (I/O/sec) The average number of write requests to the disk per second. Read Bandwidth (MB/s) The average amount of data read from the disk in Mbytes per second. Write Bandwidth (MB/s) The average amount of data written to the disk in Mbytes per second. Average Busy Queue Length The average number of requests waiting at a busy disk to be serviced, including the request that is currently in service. CLARiiON SP, LUN and DISK performance data is retrieved and processed daily. Raw performance data is kept for a longer term, i.e. 180 days, and CLARiiON performance reports are kept indefinitely for performance trend analysis. Scripting Functional Design Scripting running environment For performance monitoring scripts to run, one Windows server is required. OS version: Network: Windows 2003 server standard Edition with SP1 IP connectivity to multiple CLARiiON storage systems at different sites TCP/UDP ports allowed: , 80/443, 5414/7338, 23 Scripting language: ActivePerl EMC software: Navisphere CLI 6.19 Java: JRE Scheduling: Microsoft Scheduled Tasks Navisphere Account: username/ password; privilege: monitor; domain: local Primary functions Retrieve raw performance data from multiple CLARiiON storage systems Extract required SP, LUN and DISK performance metrics Process SP, LUN and DISK temp data, generate daily CLARiiON performance report for all sites, and calculate Average and Maximum values. 6
7 1. Retrieve performance raw data Run this script daily to retrieve the last 26 hours of analyzer history data from each CLARiiON. IP addresses of SPA on CLARiiON storage systems are stored in a text file cx_list. Script name: retr_nar_daily.pl Input file: C:\cx_list Log file: C:\log\retr_log Output files: Raw performance data will be stored in directory C:\narData\ Raw data file name will follow the naming convention as: YYYY_ MM_DD_ <Array_SN>_SPA.nar 2. Extract performance metrics from the raw data, and stored in directory C:\narData\; Object and perf_metric_code specification are stored in text file C:\obj_metric_list; temp files will be stored in C:\Temp\ directory. Script name: extract_perf_metric_daily.pl Input file: C:\narData\*.nar C:\obj_metric_list C:\cx_list Log file: C:\Log\extr_log Output file: temporary performance data will be stored in directory C:\Temp\ Temp data file name will follow the naming convention as: YYYY_ MM_DD_ <Array_SN>_temp_s (SP) YYYY_ MM_DD_ <Array_SN>_temp_l (LUN) YYYY_ MM_DD_ <Array_SN>_temp_d (DISK) 3. Concatenate 3 temp files for each CLARiiON storage array (one for sp, one for lun and one for disk) into a single file for each array. Process each concatenated file to generate a daily report for each array, and store in./report/ directory. Since there are more than 140 entries for each object, we calculate only maximum and average values instead of listing all entries. Script name: cat_files_daily.pl Input file: C:\Temp\<Array_SN> temp_s (SP) C:\Temp\<Array_SN> temp_l (LUN) C:\Temp\<Array_SN> temp_d (DISK) Log file: C:\Log\cat_log Output file: performance report will be stored in directory C:\Report\, Report file name will follow the naming convention as: YYYY_ MM_DD_ <Array_SN> Other considerations All applications running on CLARiiON utilize a number of LUNs. So, if we know how many LUNs are being used by an application, we can aggregate related LUN performance metrics to calculate application level performance metrics. CLARiiON performance monitoring scripts can easily be made application-aware (i.e. SQL server database, Exchange storage groups and Oracle database, etc.) by using an extra layer of mapping. 7
8 Script operation guide 1. Retrieve each CLARiiON nar files for the last 24 hours, run script: C:\retr_nar_daily.pl, 2. Extract required performance metrics from each nar file, generate temp files( 3 files for each array, ending temp_s, temp_l and temp_d, run script: C:\extract_perf_metric_daily.pl, 3. Generate CLARiiON performance daily report, saved in./report/directory, run script: C:\cat_files_daily.pl 4. Schedule first task starting at 1:00am daily, second task starting at 1:05am, and the third one at 1:10am Script Adjustment Considerations 1. Add new storage array Append the array serial number and SP A IP address in one line to file cx_list, the CLARiiON array will be polled as long as there is IP connectivity between the script server and the new CLARiiON array, and a proper security setting. 2. Remove decommissioned storage array Remove the array serial number and SP A IP address in one line from file cx_list, the decommissioned array will no longer be polled. 3. Change performance metrics Add/remove performance metric codes in file obj_metric_list, adjust script cat_file_daily.pl for report formatting. 4. File management can be added later to prevent unmanaged log or nar files from using all available disk space. 8
9 Professional Biography Derek is a Senior Consultant at Bell Canada with more than 15 years experiences in the IT industry. He gained extensive experience with design and implementation of major aspects of Enterprise Storage Network, specializes in enterprise storage systems, including enterprise storage implementation and data migration in SAN and NAS environments, and Enterprise high availability systems solutions. Derek also holds various EMC Proven Professional certifications (IE expert or TA specialist in different disciplines, including CLARiiON, Symmetrix and NAS.) Reference 1. Navisphere Analyzer Administrator s Guide, P/N REV A08 9
Navisphere Quality of Service Manager (NQM) Applied Technology
Applied Technology Abstract Navisphere Quality of Service Manager provides quality-of-service capabilities for CLARiiON storage systems. This white paper discusses the architecture of NQM and methods for
eg Enterprise v5.2 Clariion SAN storage system eg Enterprise v5.6
EMC Configuring Clariion and SAN and Monitoring Monitoring storage an system EMC an eg Enterprise v5.2 Clariion SAN storage system eg Enterprise v5.6 Restricted Rights Legend The information contained
EMC Navisphere Manager ADMINISTRATOR S GUIDE P/N 069001125 REV A12
EMC Navisphere Manager ADMINISTRATOR S GUIDE P/N 069001125 REV A12 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508 -435-1000 www.emc.com Copyright 2003-2005 EMC Corporation. All
Reference Architecture. EMC Global Solutions. 42 South Street Hopkinton MA 01748-9103 1.508.435.1000 www.emc.com
EMC Backup and Recovery for SAP with IBM DB2 on IBM AIX Enabled by EMC Symmetrix DMX-4, EMC CLARiiON CX3, EMC Replication Manager, IBM Tivoli Storage Manager, and EMC NetWorker Reference Architecture EMC
Domain Management with EMC Unisphere for VNX
White Paper Domain Management with EMC Unisphere for VNX EMC Unified Storage Solutions Abstract EMC Unisphere software manages EMC VNX, EMC Celerra, and EMC CLARiiON storage systems. This paper discusses
EMC Unisphere for VMAX Database Storage Analyzer
EMC Unisphere for VMAX Database Storage Analyzer Version 8.1.0 Online Help (PDF version) Copyright 2014-2015 EMC Corporation. All rights reserved. Published in USA. Published September, 2015 EMC believes
EMC NetWorker VSS Client for Microsoft Windows Server 2003 First Edition
EMC NetWorker VSS Client for Microsoft Windows Server 2003 First Edition Installation Guide P/N 300-003-994 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com
Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments
Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments Applied Technology Abstract This white paper introduces EMC s latest groundbreaking technologies,
AX4 5 Series Software Overview
AX4 5 Series Software Overview March 6, 2008 This document presents an overview of all software you need to configure and monitor any AX4 5 series storage system running the Navisphere Express management
Enterprise Manager. Version 6.2. Installation Guide
Enterprise Manager Version 6.2 Installation Guide Enterprise Manager 6.2 Installation Guide Document Number 680-028-014 Revision Date Description A August 2012 Initial release to support version 6.2.1
Performance Impact on Exchange Latencies During EMC CLARiiON CX4 RAID Rebuild and Rebalancing Processes
Performance Impact on Exchange Latencies During EMC CLARiiON CX4 RAID Rebuild and Applied Technology Abstract This white paper discusses the results of tests conducted in a Microsoft Exchange 2007 environment.
TRACE PERFORMANCE TESTING APPROACH. Overview. Approach. Flow. Attributes
TRACE PERFORMANCE TESTING APPROACH Overview Approach Flow Attributes INTRODUCTION Software Testing Testing is not just finding out the defects. Testing is not just seeing the requirements are satisfied.
Enable Connectivity for 3PAR Storage:
Enable Connectivity for 3PAR Storage: Call Home Benefit: Periodically, the Service Processor transfers the diagnostic information such as system health information, configuration data, performance data,
MEGA Web Application Architecture Overview MEGA 2009 SP4
Revised: September 2, 2010 Created: March 31, 2010 Author: Jérôme Horber CONTENTS Summary This document describes the system requirements and possible deployment architectures for MEGA Web Application.
Monitoring FibreCAT CX systems with ServerView Operations Manager
User Guide - English FUJITSU Software ServerView Suite Monitoring FibreCAT CX systems with ServerView Operations Manager Edition May 2009 Comments Suggestions Corrections The User Documentation Department
EMC VNX-F ALL FLASH ARRAY
EMC VNX-F ALL FLASH ARRAY Purpose-built for price, density & speed ESSENTIALS Incredible scale & density with up to 172 TB usable flash capacity in 6U @ 28.63 TB/U Consistent high performance up to 400K
Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems
Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems Applied Technology Abstract This white paper investigates configuration and replication choices for Oracle Database deployment with EMC
The EMC CLARiiON Navisphere Command Line Interface (CLI): History and Best Practices
The EMC CLARiiON Navisphere Command Line Interface (CLI): History and Best Practices A Detailed Review Abstract This white paper describes the EMC Navisphere Command Line Interface (CLI). It describes
The Effect of Priorities on LUN Management Operations
Abstract This white paper describes the effect of each of the four Priorities (ASAP, High, Medium, and Low) on overall EMC CLARiiON performance in executing. The LUN Management Operations are migrate,
TANDBERG MANAGEMENT SUITE 10.0
TANDBERG MANAGEMENT SUITE 10.0 Installation Manual Getting Started D12786 Rev.16 This document is not to be reproduced in whole or in part without permission in writing from: Contents INTRODUCTION 3 REQUIREMENTS
Performance White Paper
Sitecore Experience Platform 8.1 Performance White Paper Rev: March 11, 2016 Sitecore Experience Platform 8.1 Performance White Paper Sitecore Experience Platform 8.1 Table of contents Table of contents...
EMC EXAM - E20-611. CLARiiON Installation and Troubleshooting Specialist Exam. Buy Full Product. http://www.examskey.com/e20-611.
EMC EXAM - E20-611 CLARiiON Installation and Troubleshooting Specialist Exam Buy Full Product http://www.examskey.com/e20-611.html Examskey EMC E20-611 exam demo product is here for you to test the quality
Performance Counters. Microsoft SQL. Technical Data Sheet. Overview:
Performance Counters Technical Data Sheet Microsoft SQL Overview: Key Features and Benefits: Key Definitions: Performance counters are used by the Operations Management Architecture (OMA) to collect data
EMC Replication Manager for Virtualized Environments
EMC Replication Manager for Virtualized Environments A Detailed Review Abstract Today s IT organization is constantly looking for ways to increase the efficiency of valuable computing resources. Increased
StreamServe Persuasion SP4
StreamServe Persuasion SP4 Installation Guide Rev B StreamServe Persuasion SP4 Installation Guide Rev B 2001-2009 STREAMSERVE, INC. ALL RIGHTS RESERVED United States patent #7,127,520 No part of this document
Oracle Database Scalability in VMware ESX VMware ESX 3.5
Performance Study Oracle Database Scalability in VMware ESX VMware ESX 3.5 Database applications running on individual physical servers represent a large consolidation opportunity. However enterprises
Avatier Identity Management Suite
Avatier Identity Management Suite Migrating AIMS Configuration and Audit Log Data To Microsoft SQL Server Version 9 2603 Camino Ramon Suite 110 San Ramon, CA 94583 Phone: 800-609-8610 925-217-5170 FAX:
Hitachi Path Management & Load Balancing with Hitachi Dynamic Link Manager and Global Link Availability Manager
Hitachi Data System s WebTech Series Hitachi Path Management & Load Balancing with Hitachi Dynamic Link Manager and Global Link Availability Manager The HDS WebTech Series Dynamic Load Balancing Who should
Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010
Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010 This document describes the different types of Unisphere management stations and tells how to install
The IntelliMagic White Paper: SMI-S for Data Collection of Storage Performance Metrics. December 2010
The IntelliMagic White Paper: SMI-S for Data Collection of Storage Performance Metrics December 2010 Summary: This paper examines the fundamentals of SMI-S by providing a definition of SMI-S, an overview
Installing Management Applications on VNX for File
EMC VNX Series Release 8.1 Installing Management Applications on VNX for File P/N 300-015-111 Rev 01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
White Paper. Recording Server Virtualization
White Paper Recording Server Virtualization Prepared by: Mike Sherwood, Senior Solutions Engineer Milestone Systems 23 March 2011 Table of Contents Introduction... 3 Target audience and white paper purpose...
DELL EMC solutions for Microsoft: Maximizing your Microsoft Environment. by Philip Olenick, DELL Solutions
DELL EMC solutions for Microsoft: Maximizing your Microsoft Environment by Philip Olenick, DELL Solutions The PLATFORM Blade power PowerEdge 1955 Chassis w Dual Core and Quad Core processors!!! Port for
Monitoring the Hitachi Storage Devices
Monitoring the Hitachi Storage Devices eg Enterprise Version 6.0 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part of this
EMC Unified Storage for Microsoft SQL Server 2008
EMC Unified Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON and EMC FAST Cache Reference Copyright 2010 EMC Corporation. All rights reserved. Published October, 2010 EMC believes the information
StreamServe Persuasion SP5 Control Center
StreamServe Persuasion SP5 Control Center User Guide Rev C StreamServe Persuasion SP5 Control Center User Guide Rev C OPEN TEXT CORPORATION ALL RIGHTS RESERVED United States and other international patents
HP Storage Essentials Storage Resource Management Software end-to-end SAN Performance monitoring and analysis
HP Storage Essentials Storage Resource Management Software end-to-end SAN Performance monitoring and analysis Table of contents HP Storage Essentials SRM software SAN performance monitoring and analysis...
Installation and Configuration Guide for Windows and Linux
Installation and Configuration Guide for Windows and Linux vcenter Operations Manager 5.7 This document supports the version of each product listed and supports all subsequent versions until the document
Virtualized Exchange 2007 Archiving with EMC EmailXtender/DiskXtender to EMC Centera
EMC Solutions for Microsoft Exchange 2007 Virtualized Exchange 2007 Archiving with EMC EmailXtender/DiskXtender to EMC Centera EMC Commercial Solutions Group Corporate Headquarters Hopkinton, MA 01748-9103
Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays. Red Hat Performance Engineering
Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays Red Hat Performance Engineering Version 1.0 August 2013 1801 Varsity Drive Raleigh NC
HP StorageWorks XP Performance Advisor Software Installation Guide
HP StorageWorks XP Performance Advisor Software Installation Guide This guide describes how to install and configure HP StorageWorks XP Performance Advisor Software (XP Performance Advisor). This guide
MONITORING A WEBCENTER CONTENT DEPLOYMENT WITH ENTERPRISE MANAGER
MONITORING A WEBCENTER CONTENT DEPLOYMENT WITH ENTERPRISE MANAGER Andrew Bennett, TEAM Informatics, Inc. Why We Monitor During any software implementation there comes a time where a question is raised
opensm2 Enterprise Performance Monitoring December 2010 Copyright 2010 Fujitsu Technology Solutions
opensm2 Enterprise Performance Monitoring December 2010 Agenda opensm2 Overview INSPECTOR ANALYZER 1 opensm2 Provides a consistent solution for the enterprise-wide performance management Supports the server
Microsoft SQL Server 2005 on Windows Server 2003
EMC Backup and Recovery for SAP Microsoft SQL Server 2005 on Windows Server 2003 Enabled by EMC CLARiiON CX3, EMC Disk Library, EMC Replication Manager, EMC NetWorker, and Symantec Veritas NetBackup Reference
Monitoring EMC CLARiiON
Monitoring EMC CLARiiON eg Enterprise v6 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part of this document may be reproduced
MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX
White Paper MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX Abstract This white paper highlights EMC s Hyper-V scalability test in which one of the largest Hyper-V environments in the world was created.
WHITE PAPER Guide to 50% Faster VMs No Hardware Required
WHITE PAPER Guide to 50% Faster VMs No Hardware Required Think Faster. Visit us at Condusiv.com GUIDE TO 50% FASTER VMS NO HARDWARE REQUIRED 2 Executive Summary As much as everyone has bought into the
EMC CLARiiON PRO Storage System Performance Management Pack Guide for Operations Manager 2007. Published: 04/14/2011
EMC CLARiiON PRO Storage System Performance Management Pack Guide for Operations Manager 2007 Published: 04/14/2011 Copyright EMC2, EMC, and where information lives are registered trademarks or trademarks
Kaseya Server Instal ation User Guide June 6, 2008
Kaseya Server Installation User Guide June 6, 2008 About Kaseya Kaseya is a global provider of IT automation software for IT Solution Providers and Public and Private Sector IT organizations. Kaseya's
Enterprise Manager. Version 6.2. Administrator s Guide
Enterprise Manager Version 6.2 Administrator s Guide Enterprise Manager 6.2 Administrator s Guide Document Number 680-017-017 Revision Date Description A August 2012 Initial release to support version
HP Business Availability Center
HP Business Availability Center for the Windows and Solaris operating systems Software Version: 8.05 Business Process Monitor Administration Document Release Date:September 2010 Software Release Date:
NetApp Storage System Plug-In 12.1.0.1.0 for Oracle Enterprise Manager 12c Installation and Administration Guide
NetApp Storage System Plug-In 12.1.0.1.0 for Oracle Enterprise Manager 12c Installation and Administration Guide Sachin Maheshwari, Anand Ranganathan, NetApp October 2012 Abstract This document provides
Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems
Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems Applied Technology Abstract By migrating VMware virtual machines from one physical environment to another, VMware VMotion can
Performance Validation and Test Results for Microsoft Exchange Server 2010 Enabled by EMC CLARiiON CX4-960
Performance Validation and Test Results for Microsoft Exchange Server 2010 Abstract The purpose of this white paper is to profile the performance of the EMC CLARiiON CX4-960 with Microsoft Exchange Server
EMC CLARiiON Secure Remote Support Solutions Technical Notes P/N 300-006-009 REV A03 October 5, 2010
EMC CLARiiON Secure Remote Support Solutions Technical Notes P/N 300-006-009 REV A03 October 5, 2010 This technical note discusses the benefits, value, and implementation of EMC Secure Remote Support solutions
Windows Server Performance Monitoring
Spot server problems before they are noticed The system s really slow today! How often have you heard that? Finding the solution isn t so easy. The obvious questions to ask are why is it running slowly
System Requirements Table of contents
Table of contents 1 Introduction... 2 2 Knoa Agent... 2 2.1 System Requirements...2 2.2 Environment Requirements...4 3 Knoa Server Architecture...4 3.1 Knoa Server Components... 4 3.2 Server Hardware Setup...5
White paper: Unlocking the potential of load testing to maximise ROI and reduce risk.
White paper: Unlocking the potential of load testing to maximise ROI and reduce risk. Executive Summary Load testing can be used in a range of business scenarios to deliver numerous benefits. At its core,
Optimizing Business Continuity Management with NetIQ PlateSpin Protect and AppManager. Best Practices and Reference Architecture
Optimizing Business Continuity Management with NetIQ PlateSpin Protect and AppManager Best Practices and Reference Architecture WHITE PAPER Table of Contents Introduction.... 1 Why monitor PlateSpin Protect
EMC Business Continuity for VMware View Enabled by EMC SRDF/S and VMware vcenter Site Recovery Manager
EMC Business Continuity for VMware View Enabled by EMC SRDF/S and VMware vcenter Site Recovery Manager A Detailed Review Abstract This white paper demonstrates that business continuity can be enhanced
EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server
White Paper EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server Abstract This white paper addresses the challenges currently facing business executives to store and process the growing
LANDesk White Paper. LANDesk Management Suite for Lenovo Secure Managed Client
LANDesk White Paper LANDesk Management Suite for Lenovo Secure Managed Client Introduction The Lenovo Secure Managed Client (SMC) leverages the speed of modern networks and the reliability of RAID-enabled
WHITE PAPER Guide to 50% Faster VMs No Hardware Required
WHITE PAPER Guide to 50% Faster VMs No Hardware Required WP_v03_20140618 Visit us at Condusiv.com GUIDE TO 50% FASTER VMS NO HARDWARE REQUIRED 2 Executive Summary As much as everyone has bought into the
Installation and Configuration Guide for Windows and Linux
Installation and Configuration Guide for Windows and Linux vcenter Operations Manager 5.0.3 This document supports the version of each product listed and supports all subsequent versions until the document
HIGHLY AVAILABLE MULTI-DATA CENTER WINDOWS SERVER SOLUTIONS USING EMC VPLEX METRO AND SANBOLIC MELIO 2010
White Paper HIGHLY AVAILABLE MULTI-DATA CENTER WINDOWS SERVER SOLUTIONS USING EMC VPLEX METRO AND SANBOLIC MELIO 2010 Abstract This white paper demonstrates key functionality demonstrated in a lab environment
Server Management Tools (ASMT)
1 Auspex Server Management Tools (ASMT) Introduction This module presents the Auspex Server Management Tools, or ASMT. This is a graphical interface which allows you to perform most NetServer system administration
Comprehending the Tradeoffs between Deploying Oracle Database on RAID 5 and RAID 10 Storage Configurations. Database Solutions Engineering
Comprehending the Tradeoffs between Deploying Oracle Database on RAID 5 and RAID 10 Storage Configurations A Dell Technical White Paper Database Solutions Engineering By Sudhansu Sekhar and Raghunatha
VERITAS Software - Storage Foundation for Windows Dynamic Multi-Pathing Performance Testing
January 2003 www.veritest.com [email protected] VERITAS Software - Storage Foundation for Windows Dynamic Multi-Pathing Performance Testing Test report prepared under contract from VERITAS Software Corporation
Running a Workflow on a PowerCenter Grid
Running a Workflow on a PowerCenter Grid 2010-2014 Informatica Corporation. No part of this document may be reproduced or transmitted in any form, by any means (electronic, photocopying, recording or otherwise)
Pearl Echo Installation Checklist
Pearl Echo Installation Checklist Use this checklist to enter critical installation and setup information that will be required to install Pearl Echo in your network. For detailed deployment instructions
StreamServe Persuasion SP5 Microsoft SQL Server
StreamServe Persuasion SP5 Microsoft SQL Server Database Guidelines Rev A StreamServe Persuasion SP5 Microsoft SQL Server Database Guidelines Rev A 2001-2011 STREAMSERVE, INC. ALL RIGHTS RESERVED United
Pcounter Web Report 3.x Installation Guide - v2014-11-30. Pcounter Web Report Installation Guide Version 3.4
Pcounter Web Report 3.x Installation Guide - v2014-11-30 Pcounter Web Report Installation Guide Version 3.4 Table of Contents Table of Contents... 2 Installation Overview... 3 Installation Prerequisites
Configuring and Monitoring HP EVA StorageWorks Array
Configuring and Monitoring HP EVA StorageWorks Array eg Enterprise v5.6 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part
026-1010 Rev 7 06-OCT-2011. Site Manager Installation Guide
026-1010 Rev 7 06-OCT-2011 Site Manager Installation Guide Retail Solutions 3240 Town Point Drive NW, Suite 100 Kennesaw, GA 30144, USA Phone: 770-425-2724 Fax: 770-425-9319 Table of Contents 1 SERVER
EMC VSI for VMware vsphere: Storage Viewer
EMC VSI for VMware vsphere: Storage Viewer Version 5.6 Product Guide P/N 300-013-072 REV 07 Copyright 2010 2013 EMC Corporation. All rights reserved. Published in the USA. Published September 2013 EMC
HP and Mimosa Systems A system for email archiving, recovery, and storage optimization white paper
HP and Mimosa Systems A system for email archiving, recovery, and storage optimization white paper Mimosa NearPoint for Microsoft Exchange Server and HP StorageWorks 1510i Modular Smart Array Executive
EMC Invista: The Easy to Use Storage Manager
EMC s Invista SAN Virtualization System Tested Feb. 2006 Page 1 of 13 EMC Invista: The Easy to Use Storage Manager Invista delivers centrally managed LUN Virtualization, Data Mobility, and Copy Services
Dell One Identity Manager Scalability and Performance
Dell One Identity Manager Scalability and Performance Scale up and out to ensure simple, effective governance for users. Abstract For years, organizations have had to be able to support user communities
Oracle Enterprise Manager
Oracle Enterprise Manager System Monitoring Plug-in Installation Guide for EMC Symmetrix DMX System Release 12.1.0.2.0 E27543-03 February 2014 This document provides installation and configuration instructions
VirtualCenter Database Performance for Microsoft SQL Server 2005 VirtualCenter 2.5
Performance Study VirtualCenter Database Performance for Microsoft SQL Server 2005 VirtualCenter 2.5 VMware VirtualCenter uses a database to store metadata on the state of a VMware Infrastructure environment.
NETWRIX FILE SERVER CHANGE REPORTER
NETWRIX FILE SERVER CHANGE REPORTER ADMINISTRATOR S GUIDE Product Version: 3.3 April/2012. Legal Notice The information in this publication is furnished for information use only, and does not constitute
Maximize Your Virtual Environment Investment with EMC Avamar. Rob Emsley Senior Director, Product Marketing
1 Maximize Your Virtual Environment Investment with EMC Avamar Rob Emsley Senior Director, Product Marketing 2 Private Cloud is the Vision Virtualized Data Center Internal Cloud Trusted Flexible Control
Capacity planning for IBM Power Systems using LPAR2RRD. www.lpar2rrd.com www.stor2rrd.com
Capacity planning for IBM Power Systems using LPAR2RRD Agenda LPAR2RRD and STOR2RRD basic introduction Capacity Planning practical view CPU Capacity Planning LPAR2RRD Premium features Future STOR2RRD quick
Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study
White Paper Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study 2012 Cisco and/or its affiliates. All rights reserved. This
The IntelliMagic White Paper on: Storage Performance Analysis for an IBM San Volume Controller (SVC) (IBM V7000)
The IntelliMagic White Paper on: Storage Performance Analysis for an IBM San Volume Controller (SVC) (IBM V7000) IntelliMagic, Inc. 558 Silicon Drive Ste 101 Southlake, Texas 76092 USA Tel: 214-432-7920
Best practices for operational excellence (SharePoint Server 2010)
Best practices for operational excellence (SharePoint Server 2010) Published: May 12, 2011 Microsoft SharePoint Server 2010 is used for a broad set of applications and solutions, either stand-alone or
Rebasoft Auditor Quick Start Guide
Copyright Rebasoft Limited: 2009-2011 1 Release 2.1, Rev. 1 Copyright Notice Copyright 2009-2011 Rebasoft Ltd. All rights reserved. REBASOFT Software, the Rebasoft logo, Rebasoft Auditor are registered
FileNet System Manager Dashboard Help
FileNet System Manager Dashboard Help Release 3.5.0 June 2005 FileNet is a registered trademark of FileNet Corporation. All other products and brand names are trademarks or registered trademarks of their
DocuShare Installation Guide
DocuShare Installation Guide Publication date: May 2009 This document supports DocuShare Release 6.5/DocuShare CPX Release 6.5 Prepared by: Xerox Corporation DocuShare Business Unit 3400 Hillview Avenue
Storage I/O Control: Proportional Allocation of Shared Storage Resources
Storage I/O Control: Proportional Allocation of Shared Storage Resources Chethan Kumar Sr. Member of Technical Staff, R&D VMware, Inc. Outline The Problem Storage IO Control (SIOC) overview Technical Details
Using Multipathing Technology to Achieve a High Availability Solution
Using Multipathing Technology to Achieve a High Availability Solution Table of Contents Introduction...3 Multipathing Technology...3 Multipathing I/O Implementations...5 Storage Redundancy...5 Infortrend
Scalable NAS for Oracle: Gateway to the (NFS) future
Scalable NAS for Oracle: Gateway to the (NFS) future Dr. Draško Tomić ESS technical consultant, HP EEM 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change
Novell ZENworks Asset Management 7.5
Novell ZENworks Asset Management 7.5 w w w. n o v e l l. c o m October 2006 INSTALLATION GUIDE Table Of Contents 1. Installation Overview... 1 If you are upgrading... 1 Installation Choices... 1 ZENworks
HP LeftHand SAN Solutions
HP LeftHand SAN Solutions Support Document Applications Notes Best Practices for Using SolarWinds' ORION to Monitor SANiQ Performance Legal Notices Warranty The only warranties for HP products and services