percutaneous coronary intervention PCI PCI 1 PCI coronary rotational atherectomy 1 CT coronary computed tomographic angiography CCTA Agatston 100

Size: px
Start display at page:

Download "percutaneous coronary intervention PCI PCI 1 PCI coronary rotational atherectomy 1 CT coronary computed tomographic angiography CCTA Agatston 100"

Transcription

1 Chin J Intervent Cardiol, 2014, Vol 22, No.2 69 R541.4 percutaneous coronary interventionpci coronary rotational atherectomy % DOI /j. issn [1-2] PCI 1 PCI 2 3 [3-4] CT 1 CT coronary computed tomographic angiographyccta Agatston % 95% 79% 0 50% 96% 100%

2 Chin J Intervent Cardiol, 2014, Vol 22, No %89% 98% X 3 intravascular ultrasound IVUSIVUS 90% 100% IVUS IVUS IVUS IVUS 4 optical coherence tomographyoct 96% 97% IVUS OCT PCI 1 CCTA 2 PCI CCTA IVUS OCT IVUS OCT 3 4 PCI 5 16 atm1 atm=101.3 kpa 16 atm 6 IVUS atm 2noncompliant balloon NB 3cutting ballooncb [5-7] IVUS 12 atm 1 2 mm2 20 mm % mm 80 David Auth 1988 Bertrand 1993 FDA 90% 95% drug eluting stentsdes 1 burr

3 Chin J Intervent Cardiol, 2014, Vol 22, No.2 71 DES [8-16] CTO [8,17] mm7 4 1 [18-19] 15 s 2 / / [18-19] 15 s b/ a PCI 1 2 CABG PCI IVUS CABG mm5 6

4 Chin J Intervent Cardiol, 2014, Vol 22, No.2 CCTAIVUSOCT DES IVUS PCI DES 1 Alexopoulos N, Raggi P. Calcification in atherosclerosis. Nat Rev Cardiol, 2009, Williams M, Shaw LJ, Raggi P, et al. Prognostic value of number and site of calcified coronary lesions compared with the total score. J Am Coll Cardiol Img, 2008, Tanigawa J, Barlis P, Di Mario C. Heavily calcified coronary lesions preclude strut apposition despite high pressure balloon dilation and rotational atherectomy: in-vivo demonstration with optical conherence tomography. Circ J, 2008, Reimers B, von Birgelen C, van der Giessen WJ, et al. A word of caution on optimizing stent deployment in calcified lesions: acute coronary rupture with cardiac tamponade. Am Heart J, 1996, Mauri L, Bonan R, Weiner BH, et al. Cutting balloon angioplasty for the prevention of restenosis: Results of the cutting Balloon Global Randomized Trial. Am J Cardiol, 2002, Albiero R, Silber S, Di Mario C, et al. Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis: Result of the restenosis cutting balloon evaluation trial (RESCUT). J Am Coll Cardiol, 2004, Levine GN, Bates ER, Blankenship JC, et al ACCF/AHA/ SCAI Guideline for Percutaneous Coronary Intervention: A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions. Circulation, 2011, 124 e Moussa I, Di Mario C, Moses J, et al. Coronary stenting after

5 Chin J Intervent Cardiol, 2014, Vol 22, No.2 73 rotational atherectomy in calcified and complex lesions Angiographic and clinical follow-up results. Circulation, 1997, Ellis SG, Popma JJ, Buchbinder M, et al. Relation of clinical presentation, stenosis morphology, and operator technique to the procedural results of rotational atheretomy and rotational atherectomy-facilitated angioplasty. Circulation, 1994, Kobayashi Y, Teirstein P, Linnemeier T, et al. Rotational atherectomy (stentablation) in a lesion with stent underexpansion due to heavily calcified plaque. Catheter Cardiovasc Interv, 2001, Khattab AA, Otto A, Hochadel M, et al. Drug-eluting stents versus bare metal stents following rotational atherectomy for heavily calcified coronary lesions: late angiographic and clinical follow-up results. J Interv Cardiol, 2007, Hoffmann R, Mintz GS, Kent KM, et al. Comparative early and nine-month results of rotational atherectomy, stents, and the combination of both for calcified lesions in large coronary arteries. Am J Cardiol, 1998, Clavijo LC, Steinberg DH, Torguson R, et al. Sirolimus-eluting stents and clacified lesions: clinical outcomes of patients treated with and without rotational atherectomy. Catheter Cardiovasc Interv, 2006, Mezilis N, Dardas P, Ninios V, et al. Rotablation in the Drug Eluting Era: Immediate and Long-Term Results from a Single Center Experience. J Interv Cardiol, 2012, Benezet J, Diaz de la Llera LS, Cubero JM, et al. Drug-eluting stents following rotational atherectomy for heavily calcified coronary lesions: long-term clinical outcomes. J Invasive Cardiol, 2011, Rathore S, Matsuo H, Terashima M, et al. Rotational atherectomy for fibro-calcific coronary artery disease in drug eluting stent era: Procedural outcomes and angiographic follow-up results. Catheter Cardiovasc Interv, 2010, Cavusoglu E, Kini AS, Marmur JD, et al. Current Status of Rotational Atherectomy. Catheter Cardiovasc Interv, 2004, Safian RD, Feldman T, Muller DW, et al. Coronary angioplasty and Rotablator atherectomy trial (CARAT): immediate and late results of a prospective multicenter randomized trial. Catheter Cardiovasc Interv, 2001, Whitlow PL, Bass TA, Kipperman RM, et al. Results of the study to determine rotablator and transluminal angioplasty strategy (STRATAS). Am J Cardio, 2001, 87: GB/T et al Index Medicus

Clinical Research Intracoronary Stenting with Crushing in Coronary Artery Bifurcation Lesions: Initial Results and Medium-Term Follow Up

Clinical Research Intracoronary Stenting with Crushing in Coronary Artery Bifurcation Lesions: Initial Results and Medium-Term Follow Up Hellenic J Cardiol 45: 379-383, 2004 Clinical Research Intracoronary Stenting with Crushing in Coronary Artery Bifurcation Lesions: Initial Results and Medium-Term Follow Up PETROS S. DARDAS, DIMITRIS

More information

Rotational Atherectomy for the Treatment of In-Stent Restenosis

Rotational Atherectomy for the Treatment of In-Stent Restenosis Home SVCC Area: English - Español - Português Rotational Atherectomy for the Treatment of In-Stent Restenosis Steven L. Goldberg, MD Cardiac Catheterization Laboratory, University of Washington Medical

More information

European Heart Journal (1999) 20, 1014 1019 Article No. euhj.1998.1395, available online at http://www.idealibrary.com on

European Heart Journal (1999) 20, 1014 1019 Article No. euhj.1998.1395, available online at http://www.idealibrary.com on European Heart Journal (1999) 20, 1014 1019 Article No. euhj.1998.1395, available online at http://www.idealibrary.com on Working Group Report Indications for intracoronary stent placement: the European

More information

OCT ASSESSMENT OF CUTTING BALLOON ANGIOPLASTY FOR IN-STENT RESTENOSIS

OCT ASSESSMENT OF CUTTING BALLOON ANGIOPLASTY FOR IN-STENT RESTENOSIS OCT ASSESSMENT OF CUTTING BALLOON ANGIOPLASTY FOR IN-STENT RESTENOSIS Division of Cardiology, Mount Sinai Hospital, New York, NY, USA Yuliya Vengrenyuk, PhD; and Annapoorna Kini, MD OCT ASSESSMENT OF CUTTING

More information

MEDICAL POLICY No. 91580-R1 DRUG-ELUTING STENTS FOR ISCHEMIC HEART DISEASE

MEDICAL POLICY No. 91580-R1 DRUG-ELUTING STENTS FOR ISCHEMIC HEART DISEASE DRUG-ELUTING STENTS FOR ISCHEMIC HEART DISEASE Effective Date: October 1, 2015 Review Dates: 10/11, 10/12, 10/13, 8/14, 8/15 Date Of Origin: October 12, 2011 Status: Current Summary of Changes Clarifications:

More information

Drug-Eluting Balloons. Klaus Bonaventura Department of Cardiology and Angiology Heart Thorax Vascular Center, Klinikum Ernst von Bergmann, Potsdam

Drug-Eluting Balloons. Klaus Bonaventura Department of Cardiology and Angiology Heart Thorax Vascular Center, Klinikum Ernst von Bergmann, Potsdam Drug-Eluting Balloons Klaus Bonaventura Department of Cardiology and Angiology Heart Thorax Vascular Center, Klinikum Ernst von Bergmann, Potsdam Potential conflicts of interest Speaker s name: Klaus Bonaventura

More information

Evolu'on of Balloon Angioplasty From POBA to newer technologies NCVH May 26, 2015

Evolu'on of Balloon Angioplasty From POBA to newer technologies NCVH May 26, 2015 Evolu'on of Balloon Angioplasty From POBA to newer technologies NCVH May 26, 2015 Cezar Staniloae, MD Heart and Vascular Ins7tute New York University Medical Center Overview 1. Physics of balloon angioplasty

More information

Ostial LAD: Single stent approach is the best. Antonio A. Pocoví, MD, FSCAI, MTSAC, Advisory Council Member, CACI

Ostial LAD: Single stent approach is the best. Antonio A. Pocoví, MD, FSCAI, MTSAC, Advisory Council Member, CACI Ostial LAD: Single stent approach is the best Antonio A. Pocoví, MD, FSCAI, MTSAC, Advisory Council Member, CACI Chair, Interventional Cardiology Sanatorio San Lucas Instituto Alexander Fleming Buenos

More information

Editorial. Adult Cardiology - Meta-analysis

Editorial. Adult Cardiology - Meta-analysis Editorial Adult Cardiology - Meta-analysis Simple Versus Complex Bifurcation Stenting Strategies A Meta Analysis of Randomized Controlled Trials in the Drug Eluting Stent Era Ana Beatriz R. Medrano, MD

More information

ORIGINAL ARTICLES: Morphology and Location of Restenosis Following Bare Metal Coronary Stenting

ORIGINAL ARTICLES: Morphology and Location of Restenosis Following Bare Metal Coronary Stenting Page 1 / 7 ORIGINAL ARTICLES: Morphology and Location of Restenosis Following Bare Metal Coronary Stenting - Marc J. Schweiger, MD, Ehsan Ansari, MD, Gregory R. Giugliano, MD, *James Mathew, MD, Ashequl

More information

Review of Intracoronary Radiation for In-Stent Restenosis

Review of Intracoronary Radiation for In-Stent Restenosis Review of Intracoronary Radiation for In-Stent Restenosis Robert Lew, MBBS, FRACP, Andrew Ajani, MD, Ron Waksman, MD, FACC Vascular Brachytherapy using beta and gamma radiation is the standard care for

More information

Intracoronary Stenting and. Robert A. Byrne, Julinda Mehilli, Salvatore Cassese, Franz-Josef Neumann, Susanne Pinieck, Tomohisa Tada,

Intracoronary Stenting and. Robert A. Byrne, Julinda Mehilli, Salvatore Cassese, Franz-Josef Neumann, Susanne Pinieck, Tomohisa Tada, Prospective, Randomized Trial of Paclitaxel-Eluting Balloon versus Paclitaxel-Eluting Stent versus Balloon Angioplasty for Treatment of Coronary Restenosis in Limus- Eluting Stents Intracoronary Stenting

More information

Optical Coherence Tomography Versus Intravascular Ultrasound to Evaluate Coronary Artery Disease and Percutaneous Coronary Intervention

Optical Coherence Tomography Versus Intravascular Ultrasound to Evaluate Coronary Artery Disease and Percutaneous Coronary Intervention JACC: CARDIOVASCULAR INTERVENTIONS VOL. 6, NO. 3, 2013 2013 BY THE AMERICAN COLLEGE OF CARDIOLOGY FOUNDATION ISSN 1936-8798/$36.00 PUBLISHED BY ELSEVIER INC. http://dx.doi.org/10.1016/j.jcin.2012.09.017

More information

The Bioresorbable Vascular Stent Dr Albert Ko

The Bioresorbable Vascular Stent Dr Albert Ko The Bioresorbable Vascular Stent Dr Albert Ko Dr Albert Ko MB BS, FRACP, FCSANZ Interventional/General Cardiologist Ascot Cardiology Symposium 2013 Treatment Goals for Coronary Artery Disease Relieve of

More information

California Health and Safety Code, Section 1256.01

California Health and Safety Code, Section 1256.01 California Health and Safety Code, Section 1256.01 1256.01. (a) The Elective Percutaneous Coronary Intervention (PCI) Pilot Program is hereby established in the department. The purpose of the pilot program

More information

Duration of Dual Antiplatelet Therapy After Coronary Stenting

Duration of Dual Antiplatelet Therapy After Coronary Stenting Duration of Dual Antiplatelet Therapy After Coronary Stenting C. DEAN KATSAMAKIS, DO, FACC, FSCAI INTERVENTIONAL CARDIOLOGIST ADVOCATE LUTHERAN GENERAL HOSPITAL INTRODUCTION Coronary artery stents are

More information

STONY BROOK UNIVERSITY HOSPITAL VASCULAR CENTER CREDENTIALING POLICY

STONY BROOK UNIVERSITY HOSPITAL VASCULAR CENTER CREDENTIALING POLICY STONY BROOK UNIVERSITY HOSPITAL VASCULAR CENTER CREDENTIALING POLICY Per Medical Board decision March 18, 2008: These credentialing standards do NOT apply to peripheral angiography performed in the context

More information

SAMPLE. Asia-Pacific Interventional Cardiology Procedures Outlook to 2020. Reference Code: GDMECR0061PDB. Publication Date: May 2014

SAMPLE. Asia-Pacific Interventional Cardiology Procedures Outlook to 2020. Reference Code: GDMECR0061PDB. Publication Date: May 2014 Asia-Pacific Interventional Cardiology Procedures Outlook to 2020 Reference Code: GDMECR0061PDB Publication Date: May 2014 Page 1 1 Table of Contents 1 Table of Contents... 2 1.1 List of Tables... 4 1.2

More information

Coronary Bifurcation Treatment: Update from the European Bifurcation Club. Remo Albiero, MD Ist. Clinico S. Rocco Brescia (Italy)

Coronary Bifurcation Treatment: Update from the European Bifurcation Club. Remo Albiero, MD Ist. Clinico S. Rocco Brescia (Italy) Coronary Bifurcation Treatment: Update from the European Bifurcation Club Remo Albiero, MD Ist. Clinico S. Rocco Brescia (Italy) Disclosure Statement of Financial Interest Within the past 12 months, I

More information

PRECOMBAT Trial. Seung-Whan Lee, MD, PhD On behalf of the PRECOMBAT Investigators

PRECOMBAT Trial. Seung-Whan Lee, MD, PhD On behalf of the PRECOMBAT Investigators Premier of Randomized Comparison of Bypass Surgery versus Angioplasty Using Sirolimus-Eluting Stent in Patients with Left Main Coronary Artery Disease PRECOMBAT Trial Seung-Whan Lee, MD, PhD On behalf

More information

Status of Drug-Eluting Coronary Stents

Status of Drug-Eluting Coronary Stents Status of Drug-Eluting Coronary Stents EVOLUTION OF PERCUTANEOUS CORONARY INTERVENTIONAL TECHNOLOGIES The introduction of percutaneous transluminal coronary angioplasty (PTCA) in the late1970s provided

More information

Corporate Medical Policy

Corporate Medical Policy Corporate Medical Policy Computed Tomography to Detect Coronary Artery Calcification File Name: computed_tomography_to_detect_coronary_artery_calcification Origination: 3/1994 Last CAP Review 11/2014 Next

More information

Experience of Direct Coronary Stenting at National Institute of Cardiovascular Diseases

Experience of Direct Coronary Stenting at National Institute of Cardiovascular Diseases Experience of Direct Coronary Stenting at National Institute of Cardiovascular Diseases T. Masood,T. Sagheer,D. Jan,N. Qamar,A.M.A. Faruqui ( National Institute of Cardiovascular Diseases (NICVD), Karachi.

More information

INTRODUCTION. Key Words:

INTRODUCTION. Key Words: Case Report Acta Cardiol Sin 2014;30:485 489 Successful Revascularization of Chronic Total Occlusion in Native Coronary Arteries through an Occluded Saphenous Bypass Vein Graft: A Retrograde Alternative

More information

NOVOSTE BETA-CATH SYSTEM

NOVOSTE BETA-CATH SYSTEM HOSPITAL INPATIENT AND OUTPATIENT BILLING GUIDE FOR THE NOVOSTE BETA-CATH SYSTEM INTRAVASCULAR BRACHYTHERAPY DEVICE This guide is intended solely for use as a tool to help hospital billing staff resolve

More information

CORONARY ARTERY BYPASS GRAFTS, STENTS, AND EXTRACORONARY CARDIAC DZ. Charles White MD

CORONARY ARTERY BYPASS GRAFTS, STENTS, AND EXTRACORONARY CARDIAC DZ. Charles White MD CORONARY ARTERY BYPASS GRAFTS, STENTS, AND EXTRACORONARY CARDIAC DZ Charles White MD Director of Thoracic Imaging Department of Radiology University of Maryland CORONARY ARTERY BYPASS GRAFTS First performed

More information

Repeat Coronary Revascularization Procedures after Successful Bare-Metal or Drug-Eluting Stent Implantation

Repeat Coronary Revascularization Procedures after Successful Bare-Metal or Drug-Eluting Stent Implantation Original Contribution Repeat Coronary Revascularization Procedures after Successful Bare-Metal or Drug-Eluting Stent Implantation Cynthia A. Yock, MS, J. Michael Isbill, MS, Spencer B. King III, MD, Mark

More information

Fundación Favaloro. Fundación Favaloro

Fundación Favaloro. Fundación Favaloro Superficial Femoral Artery: Which h Factors Influence Patency? Oscar A. Mendiz.MD.FACC.FSCAI Chairman hi of Interventional Cardiology dil March 2010 Name: Oscar A. Mendiz Disclosure I have the following

More information

A Post-market Study to Assess the STENTYS Self-exPanding COronary Stent In AcuTe myocardial InfarctiON in Real Life APPOSITION III

A Post-market Study to Assess the STENTYS Self-exPanding COronary Stent In AcuTe myocardial InfarctiON in Real Life APPOSITION III A Post-market Study to Assess the STENTYS Self-exPanding COronary Stent In AcuTe myocardial InfarctiON in Real Life APPOSITION III Gilles Montalescot, MD, PhD Pitié-Salpêtrière Hospital, Paris, France

More information

LEADERS: 5-Year Follow-up

LEADERS: 5-Year Follow-up LEADERS: -Year Follow-up from a Prospective, Randomized Trial of Biolimus A9-eluting Stents with a Biodegradable Polymer vs. Sirolimus-eluting Stents with a Durable Polymer : Final Report of the LEADERS

More information

Measuring ROI Based on Procedure and Reimbursement Rate

Measuring ROI Based on Procedure and Reimbursement Rate Measuring ROI Based on Procedure and Reimbursement Rate Dee Whittington RN BSN CNOR Clinical Supply Consultant Gregg Lauder MBA CMRP Senior Capital Director www.acesummitandexpo.com Topics to Cover Analyze

More information

INTERVENTION IN OSTIAL CORONARY LESIONS:

INTERVENTION IN OSTIAL CORONARY LESIONS: INTERVENTION IN OSTIAL CORONARY LESIONS: Antony (92), le 18 septembre 2013 JEAN MARC PERNES Hopital Privé Antony FRANCE Perfection of Precise Ostial Stent Placement Ostial lesions, including aorta ostial

More information

Coronary angiogram : An author view Patwary MSR

Coronary angiogram : An author view Patwary MSR The ORION Medical Journal 2008 Sep;31:599-601 Coronary angiogram : An author view Patwary MSR Abstract It is relatively safe, though minimally invasive, test. Coronary angiogram is an x-ray of the coronary

More information

Christopher M. Wright, MD, MBA Pioneer Cardiovascular Consultants Tempe, Arizona

Christopher M. Wright, MD, MBA Pioneer Cardiovascular Consultants Tempe, Arizona Christopher M. Wright, MD, MBA Pioneer Cardiovascular Consultants Tempe, Arizona Areas to be covered Historical, current, and future treatments for various cardiovascular disease: Atherosclerosis (Coronary

More information

έΰζβν αππ έκυ,νσϊίία κν1γν πλδζέκυνβί1γ π ηία δεόμνκαλ δκζόΰκμ, θν δ υγυθ άμνγνκαλ /εάμ ΚζδθδεάμΝ υλωεζδθδεάμν

έΰζβν αππ έκυ,νσϊίία κν1γν πλδζέκυνβί1γ π ηία δεόμνκαλ δκζόΰκμ, θν δ υγυθ άμνγνκαλ /εάμ ΚζδθδεάμΝ υλωεζδθδεάμν ΝΠθ ζζάθδκνσθϋ λδκν έΰκ μνεδν ιωθκ κεκη δεάμνι λδεάμ έΰζβν έκ,νσϊίί κν1γν λδζέκνβί1γ Α Α φ ; έζ δκμννένσθόμ ηί δεόμνκλ δκζόΰκμ, θν δ γθ άμνγνκλ /εάμ ΚζδθδεάμΝ λωεζδθδεάμν ένivus Scientific Director, Mediolanum

More information

The Elective Percutaneous Coronary Intervention (PCI) Pilot Program. Report to the Legislature

The Elective Percutaneous Coronary Intervention (PCI) Pilot Program. Report to the Legislature State of California Health and Human Services Agency California Department of Public Health RON CHAPMAN, MD, MPH Director & State Health Officer EDMUND G. BROWN, JR. Governor The Elective Percutaneous

More information

AND SYLLABUS FOR INTERVENTIONAL CARDIOLOGY SUBSPECIALITY TRAINING IN EUROPE

AND SYLLABUS FOR INTERVENTIONAL CARDIOLOGY SUBSPECIALITY TRAINING IN EUROPE CURRICULUM AND SYLLABUS FOR INTERVENTIONAL CARDIOLOGY SUBSPECIALITY TRAINING IN EUROPE Document prepared by: Carlo Di Mario, FESC Germano Di Sciascio, FESC Jean-Luc Dubois-Rande,FESC Rolf Michels, FESC

More information

GUIDELINES ON MEDICAL DEVICES EVALUATION OF CLINICAL DATA - A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES -

GUIDELINES ON MEDICAL DEVICES EVALUATION OF CLINICAL DATA - A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES - EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Consumer goods Cosmetics and Medical Devices MEDDEV 2.7.1 Appendix 1 December 2008 GUIDELINES ON MEDICAL DEVICES EVALUATION OF CLINICAL DATA

More information

Three-dimensional coronary reconstruction from routine single-plane coronary angiograms: in vivo quantitative validation

Three-dimensional coronary reconstruction from routine single-plane coronary angiograms: in vivo quantitative validation International Journal of Cardiovascular Interventions. 2005; 7: 141 145 ORIGINAL ARTICLE Three-dimensional coronary reconstruction from routine single-plane coronary angiograms: in vivo quantitative validation

More information

Validation of a Risk Score for Target Vessel Revascularization after Coronary Stent Implantation

Validation of a Risk Score for Target Vessel Revascularization after Coronary Stent Implantation Original Contribution Validation of a Risk Score for Target Vessel Revascularization after Coronary Stent Implantation a Alexandre S. Quadros, MD, PhD, b Fabiane Diemer, RN, b Dulce Welter, RN, Thais Modkowski,

More information

Is Stenting or Coronary Artery By-pass Grafting the Better Treatment for This Patient?

Is Stenting or Coronary Artery By-pass Grafting the Better Treatment for This Patient? Is Stenting or Coronary Artery By-pass Grafting the Better Treatment for This Patient? --- NIRS-IVUS TVC Imaging Adds Additional Information for the Heart Team Dr. Luis Tami Memorial Regional Hospital

More information

Understanding Coronary Artery Disease, Cardiac Catheterization, and Treatment Options. A Guide for Patients

Understanding Coronary Artery Disease, Cardiac Catheterization, and Treatment Options. A Guide for Patients Understanding Coronary Artery Disease, Cardiac Catheterization, and Treatment Options A Guide for Patients Coronary Artery Disease If you or a member of your family has been diagnosed with coronary artery

More information

Effects of Statins on Restenosis After Coronary Stent Implantation

Effects of Statins on Restenosis After Coronary Stent Implantation Angiology Volume 58, Number 1, 2007 55 Effects of Statins on Restenosis After Coronary Stent Implantation Hirotoshi Kamishirado, MD, *Teruo Inoue, MD, FACC,* Masashi Sakuma, MD, Tatsuhiro Tsuda, MD, Terumi

More information

The Minvasys Amazonia Pax & Nile Pax Polymer Free Paclitaxel Eluting Stent Program

The Minvasys Amazonia Pax & Nile Pax Polymer Free Paclitaxel Eluting Stent Program The Minvasys Amazonia Pax & Nile Pax Polymer Free Paclitaxel Eluting Stent Program Jean Fajadet, MD, FESC Clinique Pasteur - Toulouse - France Disclosure statement Nothing to disclose Dedicated Delivery

More information

Coding Updates for 2013: Cardiology

Coding Updates for 2013: Cardiology Coding Updates for 2013: Cardiology Presented by: David Dunn, MD, FACS CIRCC, CPC-H, CCVTC, CCC, CCS, RCC National Coding Standards Sources of information Centers for Medicare and Medicare (CMS) Provider

More information

List of Publications. Evaluation of stents and grafts. de Graaf FR, Schuijf JD. EuroIntervention 2010; 6 Suppl G: G48-56.

List of Publications. Evaluation of stents and grafts. de Graaf FR, Schuijf JD. EuroIntervention 2010; 6 Suppl G: G48-56. ist of Publications Diagnostic performance of 320-slice multidetector computed tomography coronary angiography in patients after coronary artery bypass grafting. de Graaf FR, van Velzen JE, Witkowska AJ,

More information

Drug-Eluting Coronary Stents. Paul Montero PGY-II University of Colorado Health Sciences Center Surgical Grand Rounds Resident Debate

Drug-Eluting Coronary Stents. Paul Montero PGY-II University of Colorado Health Sciences Center Surgical Grand Rounds Resident Debate Drug-Eluting Coronary Stents Paul Montero PGY-II University of Colorado Health Sciences Center Surgical Grand Rounds Resident Debate Outline Coronary Artery Disease Evolution of Percutaneous Coronary Intervention

More information

FY2015 Final Hospital Inpatient Rule Summary

FY2015 Final Hospital Inpatient Rule Summary FY2015 Final Hospital Inpatient Rule Summary Interventional Cardiology (IC) Peripheral Interventions (PI) Rhythm Management (RM) On August 4, 2014, the Centers for Medicare & Medicaid Services (CMS) released

More information

Coronary Stents. What is a Coronary Artery stent?

Coronary Stents. What is a Coronary Artery stent? What is a Coronary Artery stent? Coronary Stents A coronary stent is stainless tube with slots. It is mounted on a balloon catheter in a "crimped" or collapsed state. When the balloon of is inflated, the

More information

Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials

Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials José Albuquerque de Figueiredo Neto 1, Iara Antonia Lustosa Nogueira 1, Mabel Fernandes Figueiro 2, Anna Maria

More information

Cardiac Rehab. Home. www.homecareforyou.com. Do you suffer from a cardiac condition that is limiting your independence in household mobility?

Cardiac Rehab. Home. www.homecareforyou.com. Do you suffer from a cardiac condition that is limiting your independence in household mobility? TM Nightingale Home Cardiac Rehab Do you suffer from a cardiac condition that is limiting your independence in household mobility? Such as, 1. A recent heart attack 2. A heart condition coronary artery

More information

Early And Late Outcome For Single Versus Double Stenting For Bifurcational Coronary Artery Lesions

Early And Late Outcome For Single Versus Double Stenting For Bifurcational Coronary Artery Lesions ORIGINAL CONTRBUTION / CLINICAL INVESTIGATION Early And Late Outcome For Single Versus Double Stenting For Bifurcational Coronary Artery Lesions Aram J. Mirza Correspondence: Dr. Aram J.Mirza Interventional

More information

For the NXT Investigators

For the NXT Investigators Diagnostic performance of non-invasive fractional flow reserve derived from coronary CT angiography in suspected coronary artery disease: The NXT trial Bjarne L. Nørgaard, Jonathon Leipsic, Sara Gaur,

More information

Polymer-Based, Paclitaxel-Eluting TAXUS Liberté Stent in De Novo Lesions: The Pivotal TAXUS ATLAS Trial

Polymer-Based, Paclitaxel-Eluting TAXUS Liberté Stent in De Novo Lesions: The Pivotal TAXUS ATLAS Trial Polymer-Based, Paclitaxel-Eluting Stent in De Novo Lesions: The Pivotal TAXUS ATLAS Trial Mark A. Turco, John A. Ormiston, Jeffrey J. Popma, Lazar Mandinov, Charles D. O'Shaughnessy, Tift Mann, Thomas

More information

The left internal mammary artery (LIMA) is the

The left internal mammary artery (LIMA) is the Case Report 925 Direct Stenting of a Transradial Left Internal Mammary Artery Graft Wei-Chin Hung, MD; Bih-Fang Guo, MD, PhD; Chiung-Jen Wu, MD; Chien-Jen Chen, MD; Chih-Yuan Fang, MD Taking the transfemoral

More information

SeQuent Please balloon catheter for in-stent coronary restenosis. NICE medical technology guidance 1. Issue date: December 2010

SeQuent Please balloon catheter for in-stent coronary restenosis. NICE medical technology guidance 1. Issue date: December 2010 Issue date: December 2010 SeQuent Please balloon catheter for in-stent coronary restenosis NICE medical technology guidance 1 1 NICE medical technology guidance 1 NICE medical technology guidance 1 SeQuent

More information

SCORM. For more patient education, please visit www.cypherusa.com

SCORM. For more patient education, please visit www.cypherusa.com Attach Label Understanding Coronary Artery Disease, Cardiac Catheterization, and Treatment Options Stent Implant Card CYPHER Sirolimus-eluting Coronary Stent SCORM P.O. Box 025700 Miami, FL 33102-5700,

More information

Automatic Detection of Coronary Stent Struts in Intravascular OCT imaging

Automatic Detection of Coronary Stent Struts in Intravascular OCT imaging Automatic Detection of Coronary Stent Struts in Intravascular OCT imaging Kai Pin Tung a, Wen Zhe Shi a, Luis Pizarro a, Hiroto Tsujioka b, Hai-Yan Wang a, Ricardo Guerrero a, Ranil De Silva b, Philip

More information

Clinical Results of Unprotected Left Main Coronary Stenting

Clinical Results of Unprotected Left Main Coronary Stenting Original Articles IMAJ VOL 11 MARCH 2009 Clinical Results of Unprotected Left Main Coronary Stenting Itsik Ben-Dor MD, Hana Vaknin-Assa MD, Eli Lev MD, David Brosh MD, Shmuel Fuchs MD, Abid Assali MD and

More information

INVESTIGATION OF METALLIC SURFACE AREA OF CORONARY STENTS

INVESTIGATION OF METALLIC SURFACE AREA OF CORONARY STENTS INVESTIGATION OF METALLIC SURFACE AREA OF CORONARY STENTS Dóra Károly 1, Miksa Kovács 1, Andrew Attila Terdik 1, Eszter Bognár 1,2 1Department of Materials Science and Engineering, Faculty of Mechanical

More information

Interventional Cardiology Peripheral Interventions Rhythm Management

Interventional Cardiology Peripheral Interventions Rhythm Management FY2016 Hospital Inpatient Rule (IPPS) Interventional Cardiology Peripheral Interventions Rhythm Management On April 17, 2015 the Centers for Medicare and Medicaid Services (CMS) released the Hospital Inpatient

More information

FFR CT : Clinical studies

FFR CT : Clinical studies FFR CT : Clinical studies Bjarne Nørgaard Department Cardiology B Aarhus University Hospital Skejby, Denmark Disclosures: Research grants: Edwards and Siemens Coronary CTA: High diagnostic sensitivity

More information

CARDIAC RISKS OF NON CARDIAC SURGERY

CARDIAC RISKS OF NON CARDIAC SURGERY CARDIAC RISKS OF NON CARDIAC SURGERY N E W S T U D I E S & N E W G U I D E L I N E S W. B. C A L H O U N, M D, F A C C 2014 ACC/AHA Guideline on perioperative cardiovascular evaluation and management

More information

Payment policies are potentially a strong driver of diffusion of

Payment policies are potentially a strong driver of diffusion of Medical Devices Diffusion Of New Technology And Payment Policies: Coronary Stents The implementation of a higher payment rate for stenting did not drive the acceleration of the technology s diffusion,

More information

Cardiovascular disease has become a dominant cause of

Cardiovascular disease has become a dominant cause of Abstract Immediate and Six-month Clinical Outcome of Percutaneous Coronary Intervention in a Tertiary Hospital in the Sultanate of Oman Panduranga Prashanth, Mohamed Mukhaini, Abdulla A. Riyami, Kadhim

More information

The Pantera Lux Paclitaxel DEB Device Description and Clinical Studies. Christoph Hehrlein, University Clinic Freiburg i.br.

The Pantera Lux Paclitaxel DEB Device Description and Clinical Studies. Christoph Hehrlein, University Clinic Freiburg i.br. The Pantera Lux Paclitaxel DEB Device Description and Clinical Studies Christoph Hehrlein, University Clinic Freiburg i.br. Germany Disclosure Statement of Financial Interest Within the past 12 months,

More information

Purpose Members of the Department of Cardiology will provide cardiology services to patients of McLaren Greater Lansing.

Purpose Members of the Department of Cardiology will provide cardiology services to patients of McLaren Greater Lansing. Purpose Members of the Department of Cardiology will provide cardiology services to patients of McLaren Greater Lansing. Qualifications To be eligible for core privileges in the Department of Cardiology,

More information

OPINION OPtical frequency domain imaging vs. INtravascular ultrasound in percutaneous coronary InterventiON

OPINION OPtical frequency domain imaging vs. INtravascular ultrasound in percutaneous coronary InterventiON OPINION OPtical frequency domain imaging vs. INtravascular ultrasound in percutaneous coronary InterventiON - Baseline preliminary results - Takashi Akasaka, MD, PhD, FESC Wakayama Medical University,

More information

TAXUS Express 2. Paclitaxel-Eluting Coronary Stent System. Patient Information Guide

TAXUS Express 2. Paclitaxel-Eluting Coronary Stent System. Patient Information Guide TAXUS Express 2 Paclitaxel-Eluting Coronary Stent System Patient Information Guide 1 Table of Contents Coronary Artery Disease...2 Who Is at Risk?...3 Diagnosis of Coronary Artery Disease...3 Treatment

More information

2014 Procedural Reimbursement Guide Select Percutaneous Coronary Interventions

2014 Procedural Reimbursement Guide Select Percutaneous Coronary Interventions 2014 Procedural Reimbursement Guide Select Percutaneous Coronary Interventions IC-221010-AA Jan 2014 Page 1 of 10 Interventional Cardiology This for interventional cardiology procedures provides coding

More information

Diagnostic and Therapeutic Procedures

Diagnostic and Therapeutic Procedures Diagnostic and Therapeutic Procedures Diagnostic and therapeutic cardiovascular s are central to the evaluation and management of patients with cardiovascular disease. Consistent with the other sections,

More information

Pre-procedural ACE-activity does not predict in-stent restenosis

Pre-procedural ACE-activity does not predict in-stent restenosis A CE- ACTIVITY DOES NOT PREDICT IN- STENT RESTENOSIS Chapter 4 Pre-procedural ACE-activity does not predict in-stent restenosis Lodewijk J. Wagenaar, Braim M. Rahel, Ad J. van Boven, Adriaan A. Voors,

More information

Advances in Stent Technology

Advances in Stent Technology Nurse/Technologist Symposium Advances in Stent Technology Antonietta Tolentino, CCRN, MSN, ANP-C Adult Nurse Practitioner, Cardiac Catheterization Laboratory The Zena and Michael A. Weiner Cardiovascular

More information

Press. Siemens solutions support diagnosis and treatment of cardiovascular diseases

Press. Siemens solutions support diagnosis and treatment of cardiovascular diseases Press Healthcare Erlangen, August 29, 2015 ESC 2015: ExCel London Exhibition and Convention Center, Booth #G700 Siemens solutions support diagnosis and treatment of cardiovascular diseases New cardiovascular

More information

The Cardiac Society of Australia and New Zealand

The Cardiac Society of Australia and New Zealand The Cardiac Society of Australia and New Zealand Guidelines on Support Facilities for Coronary Angiography and Percutaneous Coronary Intervention (PCI) including Guidelines on the Performance of Procedures

More information

StentViz Enhanced Stent Visualization

StentViz Enhanced Stent Visualization GE Healthcare StentViz Enhanced Stent Visualization Dr. Morice, Dr. Lefèvre, Dr. Hovasse, Dr. Chevalier, Dr. Louvard Institut Cardiovasculaire Paris Sud, Massy, France Assessing the deployment of stents

More information

Cardiac Rehabilitation An Underutilized Class I Treatment for Cardiovascular Disease

Cardiac Rehabilitation An Underutilized Class I Treatment for Cardiovascular Disease Cardiac Rehabilitation An Underutilized Class I Treatment for Cardiovascular Disease What is Cardiac Rehabilitation? Cardiac rehabilitation is a comprehensive exercise, education, and behavior modification

More information

Will Stents of New Technology Replace Coronary Artery Bypass Surgery?

Will Stents of New Technology Replace Coronary Artery Bypass Surgery? HOSPITAL CHRONICLES 2006, SUPPLEMENT: 123 127 CARDIOLOGY UPDATE 2006 Will Stents of New Technology Replace Coronary Artery Bypass Surgery? Manolis Vavuranakis, MD A B S T R A C T Hippokration University

More information

Percutaneous coronary interventions in Europe 1992-2003

Percutaneous coronary interventions in Europe 1992-2003 Working Group 10 column Percutaneous coronary interventions in Europe 1992-2003 Stéphane Cook, Mario Togni, Nazan Walpoth, Willibald Maier, Volker Muehlberger, Victor Legrand, Davor Milicic, Costakis Zambartas,

More information

Credentials for Peripheral Angioplasty: Comments on Society of Cardiac Angiography and Intervention Revisions

Credentials for Peripheral Angioplasty: Comments on Society of Cardiac Angiography and Intervention Revisions Credentials for Peripheral Angioplasty: Comments on Society of Cardiac Angiography and Intervention Revisions David Sacks, MD, Gary J. Becker, MD, and Terence A.S. Matalon, MD J Vasc Interv Radiol 2003;

More information

Appendix. Costing Case Samples for OOHCA

Appendix. Costing Case Samples for OOHCA Appendix Costing Case Samples for OOHCA The patient (ICD-1) Treatment Codes (OPCS 4) Patient 27 Admitted to ICU following percutaneous cardiac intervention (PCI) with 2 drugeluting stents following a VF

More information

2015 European Coronary Stent New Product Innovation Award

2015 European Coronary Stent New Product Innovation Award 2015 European Coronary Stent New Product Innovation Award 2015 Contents Background and Company Performance... 3 Industry Challenges... 3 New Product Attributes and Customer Impact... 3 Conclusion... 4

More information

A Patient Information Guide for the CYPHER Sirolimus-eluting Coronary Stent

A Patient Information Guide for the CYPHER Sirolimus-eluting Coronary Stent bringing evidence to life Understanding Coronary Artery Disease, Cardiac Catheterization, and Treatment Options A Patient Information Guide for the CYPHER Sirolimus-eluting Coronary Stent Patient s Name

More information

Renovascular Disease. Renal Artery and Arteriosclerosis

Renovascular Disease. Renal Artery and Arteriosclerosis Other names: Renal Artery Stenosis (RAS) Renal Vascular Hypertension (RVH) Renal Artery Aneurysm (RAA) How does the normal kidney work? The blood passes through the kidneys to remove the body s waste.

More information

GRAFTMASTER RX Coronary Stent Graft System PPL2082232 (2/1/13)

GRAFTMASTER RX Coronary Stent Graft System PPL2082232 (2/1/13) GRAFTMASTER RX Coronary Stent Graft System PPL2082232 (2/1/13) Graphical Symbols for Medical Device Labeling Manufacturer Sterilized using ethylene oxide Catalogue number Batch code French size Outer diameter

More information

World class academic leadership for your clinical trials

World class academic leadership for your clinical trials World class academic leadership for your clinical trials 1-1000 Clinical Sites 1-45 Countries >150,000 Patients Enrolled What is C5Research? C5Research is an academic research organization (ARO) which

More information

Samir B. Pancholy, MD, FACC, FSCAI 570-840-9852

Samir B. Pancholy, MD, FACC, FSCAI 570-840-9852 Samir B. Pancholy, MD, FACC, FSCAI 570-840-9852 Medical School: B.J. Medical College, Ahmedabad, India 6-1981 to 5-1987. Residency: State University of New York at Stony Brook, Stony Brook, NY, Internal

More information

Cilostazol versus Clopidogrel after Coronary Stenting

Cilostazol versus Clopidogrel after Coronary Stenting Cilostazol versus Clopidogrel after Coronary Stenting Seong-Wook Park, MD, PhD, FACC Division of Cardiology, Asan Medical Center University of Ulsan College of Medicine Seoul, Korea AMC, 2004 Background

More information

Review Article CORONARY STENTS - PAST, PRESENT AND FUTURE.

Review Article CORONARY STENTS - PAST, PRESENT AND FUTURE. Review Article CORONARY STENTS - PAST, PRESENT AND FUTURE. VV JAIN*, S YELWATKAR**, OP GUPTA*** Introduction The advent of period of angioplasty has revolutionized the practice of interventional cardiology.

More information

2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention

2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention J_ID: Z7V Customer A_ID: 2011_PCI_Guideline Cadmus Art: CCD23390 Date: 3-November-11 Stage: Page: 1 ID: kandasamy.d I Black Lining: [ON] I Time: 12:16 I Path: N:/3b2/CCD#/Vol00000/110478/APPFile/JW-CCD#110478

More information

TECHNOLOGICAL INNOVATION FOR CORONARY STENTS Francesco Migliavacca

TECHNOLOGICAL INNOVATION FOR CORONARY STENTS Francesco Migliavacca LABORATORY OF BIOLOGICAL STRUCTURE MECHANICS www.labsmech.polimi.it TECHNOLOGICAL INNOVATION FOR CORONARY STENTS Francesco Migliavacca Erice, 1 maggio 2015 International School of Cardiac Surgery Introduction

More information

Ch. 138 CARDIAC CATHETERIZATION SERVICES 28 138.1 CHAPTER 138. CARDIAC CATHETERIZATION SERVICES GENERAL PROVISIONS

Ch. 138 CARDIAC CATHETERIZATION SERVICES 28 138.1 CHAPTER 138. CARDIAC CATHETERIZATION SERVICES GENERAL PROVISIONS Ch. 138 CARDIAC CATHETERIZATION SERVICES 28 138.1 CHAPTER 138. CARDIAC CATHETERIZATION SERVICES Sec. 138.1 Principle. 138.2. Definitions. GENERAL PROVISIONS PROGRAM, SERVICE, PERSONNEL AND AGREEMENT REQUIREMENTS

More information

Future of the Coronary Stent Market: Who Will Win and Why? Jiny Kim Nimish Parikh Rebecca White

Future of the Coronary Stent Market: Who Will Win and Why? Jiny Kim Nimish Parikh Rebecca White Future of the Coronary Stent Market: Who Will Win and Why? Jiny Kim Nimish Parikh Rebecca White May 11, 2005 Executive Summary Heart disease and heart failure are two of the most prevalent health conditions

More information

PATIENT INFORMATION BOOKLET

PATIENT INFORMATION BOOKLET PATIENT INFORMATION BOOKLET Wingspan Stent System with Gateway PTA Balloon Catheter TABLE OF CONTENTS Definitions... 2 What is the Purpose of This Booklet?... 3 What is an Intracranial Lesion?... 3 Who

More information

First Experience With Drug-Eluting Balloons in Infrapopliteal Arteries

First Experience With Drug-Eluting Balloons in Infrapopliteal Arteries Journal of the American College of Cardiology Vol. 58, No. 11, 2011 2011 by the American College of Cardiology Foundation ISSN 0735-1097/$36.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2011.05.034

More information

Division of Cardiology and Cardiac Surgery, Kofu Johnan Hospital, 753-1 Kamichou, Kofu, Yamanashi, Japan

Division of Cardiology and Cardiac Surgery, Kofu Johnan Hospital, 753-1 Kamichou, Kofu, Yamanashi, Japan Yamanashi Med. J. 14(2), 43~ 49, 1999 Adjunctive Coronary Stenting Improves the Six-Month Rate of Stenosis in Patients with Acute Myocardial Infarction vs. Direct Balloon Angioplasty Alone and Adjunctive

More information

Antonio Colombo MD on behalf of the SECURITY Investigators

Antonio Colombo MD on behalf of the SECURITY Investigators Second Generation Drug-Eluting Stents Implantation Followed by Six Versus Twelve-Month - Dual Antiplatelet Therapy - The SECURITY Randomized Clinical Trial Antonio Colombo MD on behalf of the SECURITY

More information

MYOCARDIAL PERFUSION COMPUTED TOMOGRAPHY PhD course in Medical Imaging. Anne Günther Department of Radiology OUS Rikshospitalet

MYOCARDIAL PERFUSION COMPUTED TOMOGRAPHY PhD course in Medical Imaging. Anne Günther Department of Radiology OUS Rikshospitalet MYOCARDIAL PERFUSION COMPUTED TOMOGRAPHY PhD course in Medical Imaging Anne Günther Department of Radiology OUS Rikshospitalet CORONARY CT ANGIOGRAPHY (CTA) Accurate method in the assessment of possible

More information

TAXUS Express2 Paclitaxel-Eluting Coronary Stent System TAXUS Liberté Paclitaxel-Eluting Coronary Stent System. A Patient s Guide

TAXUS Express2 Paclitaxel-Eluting Coronary Stent System TAXUS Liberté Paclitaxel-Eluting Coronary Stent System. A Patient s Guide TAXUS Express2 Paclitaxel-Eluting Coronary Stent System TAXUS Liberté Paclitaxel-Eluting Coronary Stent System A Patient s Guide Table of Contents Coronary Artery Disease... 2 Who Is at Risk?... 3 Diagnosis

More information