Defluoridation of water using Activated Alumina Technology: Studies carried out at IIT Kanpur *
|
|
|
- Dorcas Clark
- 10 years ago
- Views:
Transcription
1 Defluoridation of water using Activated Alumina Technology: Studies carried out at IIT Kanpur * 1. BACKGROUND Groundwater has become a source of drinking water since last few decades, due to the scarcity, non-availability and bacteriological pollution of surface waters in many developing and underdeveloped countries. Millions of handpumps and deep tubewells have been installed in India since 1970, to provide safe drinking water to rural population, as groundwater is generally free of bacteriological contamination. Although this drastically reduced the incidence of water borne diseases, it has led to the emergence of chronic health effects in many parts of the country due to the excessive presence of chemical constituents like fluoride and arsenic in groundwater in some parts of the country. These have become major geo-environmental issues (1, 2). Not much attention was given in the initial stages to the presence of these chemical constituents, as clinical manifestations appear after a prolonged intake of contaminated water. Fluoride is a normal constituent of natural waters. Its concentration, however, varies depending on the water source. Surface waters seldom have fluoride concentrations beyond 0.3mg/L, except in isolated cases. Weathering of fluoride bearing minerals, volcanic and fumarolic processes as well as hydrogeological conditions can lead to higher fluoride levels in groundwater in certain areas, which become endemic for fluorosis. It is essential to consider remedial measures to control fluorosis, if fluoride levels of potable water are consistently beyond permissible levels. One possibility is to search for a safe water source locally or transport from a distant safe source through a piped water supply system. Another emerging option is rain water harvesting. Defluoridation of water should be considered only, where other options are not feasible or as an interim measure, if the other options take a long time for planning and implementation. Defluoridation methods can be broadly divided into following categories (3). 1. Chemical addition/precipitation 2. Adsorption/ion exchange 3. Membrane based technologies. Each of these methods has its own merits and limitations. By mid 1980's, it was evident that excess fluoride was present in groundwaters in many parts of the country. In 1987, Rajiv Gandhi National Drinking Water Mission estimated that about 25 million people in 8700 villages were drinking water with excess fluoride. As per recent estimates, this figure has been quoted to be 62 million (2).A Sub-Mission to control fluorosis was set up with a plan to overcome the problem. Testing of all water sources for fluoride and technology interventions were initiated in many states, Technology option considered was mainly Nalgonda technique. * Prepared by Dr. Lela Iyenger, Indian Institute of Technology, Kanpur in March 2005, for UNICEF, New Delhi
2 NEERI scientists had developed "Nalgonda Technique" for the defluoridation of drinking water. This involved the addition of alum and lime to water, followed by settling and filtration. The first report on this method was published in Based on this technology, community level (fill and draw type), handpump attachable and domestic defluoridation units were developed. Many community and hand pump defluoridation units were installed in various states. Pilot studies on domestic defluoridation units were also initiated. Activated Alumina (AA) technology is one of the widely used adsorption/ ion exchange methods for the defluoridation of potable water and many reports are available on large-scale installations (4, 5). Defluoridation in such units is carried out under supervision of skilled personnel and treated water is supplied to townships. The quality of treated water from such facilities is assured. However, this approach is not immediately feasible in developing countries, especially in rural areas. Treatment may only be possible at a community level i.e. handpump installations or at the 'point of use', i.e. domestic level. Reports on the adaptation of AA technology at handpump or home units were scarce till 1990's as this technology was rarely used in developing countries. During , use of indigenously manufactured activated alumina for fluoride removal was reported by few laboratories, including IIT Kanpur. Activated Alumina manufactured by Associated Cement Company and Indian PetroChemicals Ltd. (IPCL.) were used in most of these studies (6, 7). Venkateswara Rao and Mahajan (8) reported the development and evaluation of domestic and handpump units where activated alumina was used as the defluoridation medium. Kartikeyan et. al. (9) screened three different grades of activated alumina (particle size, < 0.4 mm) for fluoride uptake capacity as well as designed and evaluated domestic defluoridation unit. Studies carried out on defluoridation of drinking water at IIT Kanpur since 1991, using AA technology, are presented briefly in this report. Financial assistance from UNICEF during this entire period is gratefully acknowledged. 2. MAJOR AREAS OF STUDY: The initial intention of the research project in 1993 was to develop and field test a handpump based defluoridation unit that could be maintained by local communities. Around 1996, the focus of the research changed to finding solutions for domestic defluoridation. At the same time, the discontinuation of the grade of AA used (manufactured by IPCL) during , led to the screening of other grades indigenously manufactured of activated alumina for defluoridation application. Following are the major areas of study: 1. Development of handpump attached defluoridation unit. 2. Screening of indigenous activated alumina grades in domestic defluoridation units. 3. Development of Domestic Defluoridation Units. 4. Regeneration procedure for exhausted AA and the reuse potential of AA. 5. Safe disposal of spent regenerants. 2
3 2.1. Development of handpump attached defluoridation units: A cylindrical defluoridation unit was fabricated from MS sheet with the dimension of 0.5 m diameter and 1.5 m height. The unit was designed to operate in the upflow mode. 110 Kg of AA of grade G-87 (IPCL), having a particle size range of mm, was taken in the unit. This gave a bed depth around 55 cm. This unit was field tested at Makkur village, Unnao district U.P. For experimental study, a shallow India Mark II hand pump ( 35 ft depth) was installed. The defluoridation unit installation was in1993. It required the raising of hand pump discharge level with an addition to its normal pedestal and construction of an elevated platform. Users had to go up few steps to operate the handpump. A by-pass was provided to draw the water directly from the handpump for washing and bathing. The unit was maintained by lit Kanpur. Raw water fluoride concentration was in the range of 6-7 mg/l. Regeneration of exhausted activated alumina was carried out 'in situ i.e. within the column. This procedure required 8-10 hrs. Average yield of the safe water (<1.5 mg/l fluoride) per cycle was around 25,000 litres. Seventeen defluoridation cycles were completed in a span of 4 years. There was no major maintenance problem during this period. There was no complaint from the users either regarding the design or the palatability of treated water. However; community help during regeneration was minimal. The unit was dismantled in 1998, as village community got an access to piped water supply. With this installation, there was no provision for spent regenerant disposal. During this period, UNICEF approach changed from community based to domestic defluoridation unit. Hence further modifications, like incorporating provision for disposal of regenerants, were not taken up. Similar defluoridation units were fabricated and installed by M/s Gudimani for few handpumps in Shivpuri, MP. No performance details are available. As per our knowledge, six different models (designs) of handpump attachable units (which include two different models developed by PHED Rajasthan and DST Rajasthan) have been evaluated for the defluoridation of drinking water (10-14). All these are either experimental units or under the supervision of PHED and / or NGOs. Out of these, one unit has been evaluated with a specific grade of Activated Alumina, AAFS - 50, manufactured by Alcal Chemicals Limited, UK. As per the manufacturers, this product has five times higher uptake capacity as compared to normal Activated Alumina (15). This would make it cost effective for one time use and disposal in a landfill, instead of "regeneration and reuse" required for normal Activated Alumina systems. Most of the field studies, with this grade, are for arsenic removal either in handpump installations or the domestic unit. PHED, West Bengal seems to have installed many handpump units (15). Trials on Fluoride removal have been 3
4 conducted on PHED handpump sites near Bhopal at various locations. Evaluation of their performance has been carried out by Regional Research Laboratory, Bhopal (14). Comparison of performances of these handpump defluoridation unit as well as their limitations can lead to a better design. Another aspect to be considered, with handpump units, is the mode of regeneration of Activated Alumina. If in situ regeneration is to be carried out, then there should be a provision for the proper disposal of spent regenerants in the vicinity. A second option can be to collect exhausted activated alumina from the unit and regenerate at a central location 2.2. Screening of different grades of AA: The search for solutions for domestic defluoridation and the discontinuation of the grade of AA used during , mentioned earlier, led to the development of Domestic defluoridation Units (DDUs) and to the screening of indigenously manufactured grades of activated alumina for defluoridation application. Two parameters were considered as important for the field application of activated alumina. One was fluoride uptake capacity (FUC) expressed as milligrams of fluoride removed per Kg of AA and the second was reuse potential of AA in multiple defluoridation cycles. (a) Screening in DDU: Since water alkalinity was known to decrease fluoride uptake capacity by AA, most of the screening studies were carried out with test water prepared by spiking ground water (IITK borewell water) with NaF. Test water fluoride concentration was generally maintained at 10 ± 0.5 mg/l. All screening tests were performed with 3 Kg AA in a IITK fabricated domestic units, (details given in a separated section). During , more than 15 grades of indigenously manufactured AA have been screened. Many of them are tested upto 10 defluoridation cycles, i.e. regenerating exhausted AA and reusing the same AA for the next cycle. Under these experimental conditions used, FUC of indigenous AA grades ranged from 1500 mg/kg AA and 2200 mg/kg AA Studies have also been carried out on the effect of raw water characteristics as well as AA particle size, empty bed contact time on FUC, with selected grades of AA Presently AA grade AAFS-50 (Alcal Chemicals Co. U.K.) is being evaluated in our laboratory for fluoride uptake capacity. As mentioned earlier, this grade is reported to exhibit high FUC as compared to ordinary AA thus making it cost effective for one time use. The main outcomes from these studies are the improvement of indigenous AA grades and their availability of in the desired particle size range. b) General Screening procedure A uniform testing procedure for the screening AA grades is needed, if the results from different laboratories are to be compared. Further manufactures need to test their own products for improving AA quality. UNICEF specification also required that AA manufacturer / suppliers quote fluoride uptake capacity (FUC) of their product. 4
5 Determining FUC, using fluoride spiked distilled water as test water, has no significance as other ions present in groundwater that would affect the binding of fluoride to AA, would be absent. Groundwater quality varies from place to place. Hence, a simulated groundwater, prepared by adding required chemical components, has to be used for a uniform screening procedure by different manufactures With this view, a screening procedure was developed in our laboratory. Simulated test water was prepared by adding known quantities of NaHCO 3, Na 2 SO 4, CaCl 2 Na 2 SiO 4, MgCl 2 and NaF to distilled water and adjusting the ph to 7.8± 0.2 Screening was performed in a PVC/ Perspex column with 500 gm of AA. Details of experimental setup and procedure are given in Annual report, Jan-Dec 2004 (contract no.ssa/indq/2004/ ). This procedure can be used by (a) by manufacturers for FUC determination of their products. (b) For comparing different AA grades in any laboratory. (c) For comparing FUC of the same AA grade in two different laboratories i.e. for interlaboratory comparison of results. Such an approach of using simulated groundwater, for comparing different AA grades (including AAFS-50) for arsenic removal, has been recently reported by Clifford et.al. (16) Presently column screening procedure involves intermittent flow of raw water, which simulates feed conditions. Time required for screening can be further decreased by continuously passing raw water through the column. FUC under these conditions may be less as compared to intermittent addition. However this procedure can be used for quick comparison of different grades Development of Domestic Defluoridation Units - DDUs: DDUs were initially designed on the assumption that 20 litres of treated water was the daily requirement for cooking and drinking for a family. With this criterion, it was expected that 3 Kg. activated alumina would be exhausted in 2 to 3 months if fluoride concentration in water was around 4 mg/l. DDU fabricated in the laboratory consisted of two chambers, fabricated from GI sheet. 3 Kg of AA was taken in the upper chamber (24 cm dia. x 27 cm height), which gave a bed depth of 9 cm. A flow control device was fixed at the bottom of the upper chamber so as to have a flow rate of 8-10 liters per hour. From this starting point, different versions of DDUs have emerged. The quantity of activated alumina has generally become 4 Kg to 5 Kg and materials used for filter unit 5
6 include SS, HDPE (Sintex), PVC, and Terracota pots. Size of these containers is decided based on the volume of water. FUC depends on various factors such as raw water fluoride concentration, alkalinity, ph, as well as AA grade, particle size, contact time of raw water with the sorbent and AA depth. Raw water characteristic change from location to location. AA grade, particle size ( mm) and flow rate (8-10L/hr) had already been specified by UNICEF for DDU. Hence studies were carried out on the effect of AA amount and depth on specific safe water yield (SSY). SSY is defined as liters of safe water yield per kg AA Result of these studies showed: 3 kg AA: SSY : 117L-183L AA depth: 5cm-9cm 4 kg AA: SSY : 94L-206L AA depth: 6.5cm-11.5cm 5 kg AA: SSY : 133L-210L AA depth: 8.5cm-13.5cm (Experimental details in Annual Report, Jan Dec, 2004, contract no. SSA/INDQ/2004/934-0) These observations clearly indicate the importance of AA depth in safe water yield. Atleast minimum of 9cm depth is to be maintained in DDU although higher depth is preferable. Presently prototype domestic defluoridation units sent by UNICEF are being evaluated for their performance. These units have different AA grades, vary in AA amount as well as AA depth Regeneration of Exhausted Activated Alumina: Regeneration of exhausted AA and its reuse for multiple cycles is one of the main advantages of using AA for defluoridation. Extensive studies were carried out on this aspect. Different regenerants used included alum, HCI, H 2 SO 4 and NaOH. The results clearly indicated that efficient regeneration could be achieved with a combination of 1% NaOH and 0.4N H 2 SO 4 ' Some screened AA grades showed less than 20% loss during 10 defluoridation cycles. A simple 'dip regeneration procedure', appropriate for a rural set up, was developed. This required the transfer of activated alumina from domestic units to a nylon bag, dipping the bag in 10L 1 % NaOH for 8 hours (or overnight) with intermittent mixing. After washing once with raw water to remove excess alkali, the bag with AA was dipped in 10L of 0.4NH 2 SO 4 for 8 hrs. This was followed by washing with raw water to raise the ph to 6. The regenerated activated alumina was ready for the next cycle. The Dip regeneration method has been adapted in many pilot project areas in Rajasthan, A.P and UP. Main limitation of this method appeared to be intermittent mixing and the long time required for regeneration. Presently 'Bucket regeneration' procedure' has been developed which addresses the two disadvantages of the Dip method. A plastic bucket with flow control device is used to continuously pass the regenerant over the exhausted activated alumina bed. Studies indicated 6
7 the time required for regeneration decreases substantially and changes by changing the flow rate of the regenerants. This method is more user friendly and can be easily adapted in rural setups. Initially the regeneration procedure was optimized for 3 Kg activated alumina in the domestic unit. However, since 4 Kg to 5 Kg of AA is commonly being used, studies are being conducted to arrive at the optimal weight of AA (keeping depth of the AA bed constant) and the corresponding optimal regeneration procedure. Results have indicated that the efficiency of reuse steeply decreases with 5 Kg AA, if only 10 L of 1 % NaOH is used for regeneration Disposal of Spent Regenerants: Regeneration of activated alumina generates spent alkali and acid having extreme ph values. Spent alkali regenerant would also have high fluoride concentration. Safe disposal of these regenerants is thus essential. Different methods were tried for spent regenerant disposal. They included: 1. The addition of CaCI 2 to spent alkali regenerant to precipitate fluoride and then mix the supernatant with acid regenerant. 2. Simple mixing of spent alkali/acid regenerants. 3. Mixing alkali /acid regenerants and using certain additives like alum or lime to remove fluoride as well as to improve settling properties of the sludge. Results indicated that overall fluoride removal of more than 85% could be achieved using option 3. Based on these findings, it was recommended that the disposal of spent regenerants can be carried out by mixing spent alkali and acid regenerants, checking ph, adding enough lime to adjust the ph and settling the sludge for 24 hr. The supernatant solution, with low fluoride and near neutral ph, could then be drained off. It is to be however mentioned that the drain water will have high TDS, hardness and sulphate. Sludge could to be collected periodically, and used for brick making at the village level itself. This procedure has been adopted in UNICEF assisted pilot project villages in AP and Rajasthan, for the disposal of spent regenerants. 3. HANDPUMP AND DOMESTIC DEFLUORIDATION UNITS FOR RURAL AREAS, PROS AND CONS: Extensive literature is available on the application of Activated Alumina technology for defluoridation of drinking water in large treatment units (17,18). As mentioned earlier, this approach may not be feasible in developing countries, especially in rural areas and defluoridation solutions are needed only at the handpump or domestic levels. Advantages of this approach are: 1. Lower cost for treatment, as only the volume of water required for cooking and drinking, which is less than 20% of total requirement, can be treated. 2. Any chemical treatment is bound to generate waste, which needs safe disposal. As lesser volume is treated, lower will be the sludge/waste production. However success of these approaches depend upon the treatment reliability and motivation of consumers to use only the treated water for cooking and drinking, (as the untreated water is also available) as well as on various other factors. 7
8 Presently all handpump defluoridation installations, based on AA technology, are either experimental units or under the supervision of PHED. Past experience with other community units, such as iron removal, defluoridation using the Nalgonda technology, have not been generally encouraging. This is mainly due to lack of ownership by user communities and the consequent reluctance to take over management responsibility, leading to a lack of maintenance at local level by users. Other related issues are funding for maintenance, community involvement and awareness in creation of the defluoridation facility and the degree if institutional willingness to relinquish control over the installation. Under the circumstances, the sustainability of these systems under community management does not appear very encouraging. There are six different designs for handpump attachable defluoridation units. Comparison of performance of these different units as well as their limitations may lead to a better defluoridation unit design. Activated alumina in a handpump unit has to be periodically regenerated depending upon raw water characteristics, its fluoride concentration and amount of AA taken in the unit. There are two alternatives for the regeneration of activated alumina. One is "in situ" regeneration and the other option is by removing AA from the unit and transporting it to a regeneration centre. Regeneration of activated alumina leads to 6 to 8 bed volumes of wastewater. If the first option is chosen there should be a facility near the handpump for collecting the wastewater and its proper disposal. Hence the second option of centralized regeneration may be attractive, only if many handpump units are in close proximity. However, such a facility would have to be institutionally operated. Convenience of access plays a major part in water source preference of users, even disregarding considerations of source potablity. Handpump units may not be popular, where aquifer level is not deep (as in Makkur, UP). In such places users would be having shallow hand pumps within their homesteads and they would not prefer to get the treated water from the community hand pump. Domestic units are the "point of use" units with a higher degree of individual ownership as DDUs have to wholly or partly paid for. This might ensure better maintenance of these units if adequate regeneration facilities are simultaneously set up at the village level. However, as in the case of handpump based units, sustenance of the technology depends on the effective back-up facility for regeneration. Awareness creation is still necessary for users to be convinced of the importance of periodical regeneration. Since regeneration will be carried out at a central place, wastewater handling and disposal can be better managed. Regeneration is a very critical factor in AA based defluoridation, However, this position may change radically if it were possible to identifying a grade of AA with has a very high yield of treated water (as claimed by Alcal) so as to make it cost-effective enough to make regeneration unnecessary 8
9 References: 1. Chakraborty, D, et al. "Arsenic Calamity in the India Subcontinent what lesson have been learned", Talanta, 58,3 (2002). 2. Susheela, AK "Fluorosis Management Programme in India", Current Science, 77, 1250, (1999). 3. Killedar, DJ and Bhargava, DS "An overview of defluoridation methods (Part 1 )", J. IPHE, 2, 6 (1988).. 4. Clifford DA "Ion exchange and inorganic adsorption in water quality and treatment", Water Quality and Treatment,4 th edition, ed. Pontius, FW, McGraw- Hill Publication, 522,(1990). 5. Rubble, F Wooseley and Dale, RD, "The Removal of excess fluoride from drinking water by Activated Alumina", J. AWWA,71,45 (1979). 6. Sharma M.R., M. Tech thesis submitted to the Department of Civil Engg., lit Kanpur (1997). 7. Bulusu, KR and Nawalakhe, WG, " Defluoridation of water with Activated alumina in continuous contacting system", Indian J. Environ. Health, 32, 197, (1990). 8. Rao, VK and Mahajan, Cl, "Defluoridation of drinking water in developing countries Alternative and innovative technologies", Proc. 20th Mid Atlantic Industrial Waste conference, p 55, (1988). 9. Karthikeyan, G ; Menasha, S, and Apparel, BV, "Defluoridation technology based on activated alumina", 20thWEDC conference, Colombo, Sri Lanka, 167, (1994). 10. Mishra, K.K. "Development and performance of Handpump attachable units for defluoridation of water. M. Tech thesis. Submitted to Dept. Civil Engg. IIT Kanpur (1995) 11. Venkateswara Rao, K. "Defluoridation of drinking water by Prasanthi technique" Proc. National Workshop on defluoridation technologies for Fluorosis control organized by Sri Krishnadevaraya University, Anantapur, p. 28 (1997) 12. Dhindsa, S.S. and Davenda, H.S. "A cost effective and simple handpump attachable defluoridation unit". Proc. National Workshop on Control and Mitigation of excess Fluoride in drinking water. Jaipur (India) 5-7 th Feb. T2-8 (2004) 13. Kartikeyan, G. and Shunmuga Sundarraj, A. "Development of a handpump attachable defluoridation model based on Activated Alumina Technology" Proc. National Workshop on Control and Mitigation of excess Fluoride in drinking water. Jaipur (India) 5-7 th Feb. T - 2(56) (2004) 14. MAGC Technologies- information) 15. Alcal Chemicals-Current News(web information) 16. Clifford, D. Arsenic Treatment Technology Demonstration, Demonstration Summary, Montana University Sys tem Water Center, Montana State University Montana,( March Ruble, F, "Design Manual and removal of fluoride from drinking water supplied by activated alumina", EPA-600/2-84/134 (1984). 18. Frankel, I and Jorgen s, E "Removal of fluoride from industrial waste waters using activated alumina", EPA-600/ (1980). 9
TOXICITY OF FLUORIDE IN PARTS OF INDIAN SUBSURFACE WATER
Dr. S. K. SHARMA 24 National Road, Dehradun 248001, India E-mail: [email protected] ABSTRACT Endemic fluorosis related with the presence of fluoride in water is a public health problem in most of the
Granular Ferric Hydroxide for Elimination of Arsenic from Drinking Water
Pal : Granular Ferric Hydroxide for Elimination of Arsenic from drinking Water 59 Granular Ferric Hydroxide for Elimination of Arsenic from Drinking Water B. N. Pal M/S Pal Trockner [P] Ltd. 25/1B Ibrahimpur
Corrosivity of Water Supplies
WD-DWGB-3-4 2009 Corrosivity of Water Supplies What is meant by Corrosivity? Corrosive water can be defined as a condition of water quality which will dissolve metals from metallic plumbing at an excessive
REMOVAL OF PHOSPHATE FROM WASTEWATER USING LOW-COST ADSORBENTS
International Journal of Engineering Inventions ISSN: 2278-7461, www.ijeijournal.com Volume 1, Issue 7 (October2012) PP: 44-50 REMOVAL OF PHOSPHATE FROM WASTEWATER USING LOW-COST ADSORBENTS Dr. C.R.Ramakrishnaiah
Complete. Water Solutions. for Rural India
Complete Water Solutions for Rural India More precious than gold. That s what safe drinking water is to India s rural population. Arsenic, iron, fluoride, nitrate, brackishness and pathogens in ground
Table 1.1: Typical Characteristics of Anaerobically Digested Wastewater
Solar Detoxification of Distillery Waste Anil K. Rajvanshi and Nandini Nimbkar Nimbkar Agricultural Research Institute (NARI), P.O. Box 44, PHALTAN-415523, Maharashtra E-mail : [email protected] Introduction
Ground Water Contamination by Leachate
Ground Water Contamination by Leachate Manoj P. Wagh, Piyush K. Bhandari, Swapnil Kurhade Assistant Professor, Department of Civil Engineering, P. D. V. V. P. College of Engineering, Ahmednagar, India.
GROUND WATER CONTAMINATION INFORMATION
Ohio Department of Natural Resources Division of Oil and Gas Resources Management GROUND WATER CONTAMINATION INFORMATION Presence of Salty Water The salt that is normally found in contaminated water wells
Feasibility study of crystallization process for water softening in a pellet reactor
International A. H. Mahvi, Journal et al. of Environmental Science & Technology Feasibility study of crystallization... Vol. 1, No. 4, pp. 1-4, Winter 5 Feasibility study of crystallization process for
Ion Exchange Softening
Ion Exchange Softening Ion-exchange is used extensively in small water systems and individual homes. Ion-exchange resin, (zeolite) exchanges one ion from the water being treated for another ion that is
Ion Exchange Design Hand calculation. Brian Windsor (Purolite International Ltd)
Ion Exchange Design Hand calculation Brian Windsor (Purolite International Ltd) Introduction Before design programmes were introduced, every engineer had to calculate the design by hand using resin manufacturers
TREATMENT OPTIONS FOR REMOVAL OF SPECIFIC IMPURITIES FROM WATER. S. Vigneswaran Faculty of Engineering, University of Technology, Sydney, Australia
TREATMENT OPTIONS FOR REMOVAL OF SPECIFIC IMPURITIES FROM WATER S. Vigneswaran Faculty of Engineering, University of Technology, Sydney, Australia C. Visvanathan Asian Institute of Technology, Bangkok,
Comparative Studies for Selection of Technologies for Arsenic Removal from Drinking Water
76 Technologies for Removal of Arsenic from Drinking Water Comparative Studies for Selection of Technologies for Arsenic Removal from Drinking Water J. C. Saha Development Design Consultants Limited DDC
SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE
SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE Let us help! Free professional site visit with friendly support and advice. [email protected] to make the right decision or call
Chemistry at Work. How Chemistry is used in the Water Service
Chemistry at Work How Chemistry is used in the Water Service WATER TREATMENT Everyday, more than 100 water treatment works in Northern Ireland put approximately 680 million litres of water into the supply
A SMALL-SCALE ARSENIC AND IRON REMOVAL PLANT
A SMALL-SCALE ARSENIC AND IRON REMOVAL PLANT Introduction Groundwater is the main source of water supply in Bangladesh. Groundwater abstracted from tubewells was considered to be the best option for water
A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER
A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER ABSTRACT Leonard P. Seed, M.Sc., P.Eng., Enpar Technologies Inc. * Daren D. Yetman, A.Sc.T., Enpar Technologies
Remediation of VOC Contaminated Groundwater
Remediation of VOC Contaminated Groundwater Background Contaminated groundwater has become an ever-increasing problem in the United States and around the world. Treatment and disposal of waste is a serious
ION EXCHANGE FOR DUMMIES. An introduction
ION EXCHANGE FOR DUMMIES An introduction Water Water is a liquid. Water is made of water molecules (formula H 2 O). All natural waters contain some foreign substances, usually in small amounts. The water
Dissolved Mineral Radioactivity in Drinking Water
WD-WSEB-3-11 2004 Dissolved Mineral Radioactivity in Drinking Water General New Hampshire's bedrock contains naturally occurring radioactivity. A few examples with health importance include radon, radium
Phosphate Recovery from Municipal Wastewater through Crystallization of Calcium Phosphate
Phosphate Recovery from Municipal Wastewater through Crystallization of Calcium Phosphate A. Alamdari, Ph.D. * and S. Rohani, M.Sc. * Department of Chemical Engineering, School of Engineering, Shiraz University,
Enhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media
Enhanced Organic Precursor Removals Using Aged Media Page 1 Enhanced Organic Precursor Removals Using Aged Media O b j e c t i v e s The main goals of this project was to evaluate the dissolved organic
WASTEWATER TREATMENT OBJECTIVES
WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater
Treatment options for hydrogen sulfide. Testing for hydrogen sulfide
Sometimes hot water will have a sour smell, similar to that of an old damp rag. This smell often develops when the thermostat has been lowered to save energy or reduce the potential for scalding. Odor-causing
2. PREPARATION OF TEST SPECIMENS
Leaching of Cement Lining in Newly-Laid Water Mains (Part II) Ong Tuan Chin and Dr. Wong Sook Fun School of Civil and Environmental Engineering, Nanyang Technological University, 5 Nanyang Avenue, Singapore
q = 6.74x1 =6.74 10-1 mg/l x 3.78x10 L/d = 3.4x10 mg / day a) Single CMFR mg/g C Organic Load = Carbon requirement = 6.74 mg 1000 g C inf = 10 mg/l
Example An industrial wastewater contains 10 mg/l chlorophenol, and is going to be treated by carbon adsorption. 90% removal is desired. The wastewater is discharged at a rate of 0.1 MGD. Calculate the
QUANTITATIVE ASSESSMENT OF PHYSICOCHEMICAL CONSTITUENTS AS FLUORIDE, IRON AND NITRATE CONTAMINATED DRINKING GROUNDWATER
QUANTITATIVE ASSESSMENT OF PHYSICOCHEMICAL CONSTITUENTS AS FLUORIDE, IRON AND NITRATE CONTAMINATED DRINKING GROUNDWATER K. T. Bharati* N.D. Phatangare* Dr.D.B.Gujarathi* IN NASHIK DISTRICT, MAHARASHTRA,
IMPACT OF CHEMICALS ADDITION IN WATER/WASTEWATER TREATMENT ON TDS CONCENTRATION AND SLUDGE GENERATION Jurek Patoczka, PhD, PE Hatch Mott MacDonald 27 Bleeker Str., Millburn, NJ 07041 (973) 912 2541 [email protected]
How To Get Water To Urban Slums
Access to Safe Water for the Bottom of Pyramid: Strategies for Disseminating Technology Research Benefits Second Half Yearly Progress Report Submitted to Abercrombie House, Eaglesham Road, East Kilbride,
GUIDELINES FOR LEACHATE CONTROL
GUIDELINES FOR LEACHATE CONTROL The term leachate refers to liquids that migrate from the waste carrying dissolved or suspended contaminants. Leachate results from precipitation entering the landfill and
Using Magnesium Hydroxide
Industrial Wastewater Neutralization Using Magnesium Hydroxide May 15, 2012 Steve Leykauf, Presenter Discussion Topics What is Magnesium Hydroxide? Technical Benefits of Magnesium Hydroxide Economic Benefits
Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness
Water Softening for Removal 1 in Water High concentration of calcium (Ca2+) and magnesium (Mg2+) ions in water cause hardness Generally, water containing more than 100 mg/l of hardness expressed as calcium
How To Remove Iron From Water
ISR IRON REMOVAL MEDIA Description INDION ISR is a special media designed to provide excellent catalytic properties to remove dissolved iron from ground water. INDION ISR is an insoluble media which oxidizes
Water remediation: Passive Treatment Technologies
Presenter: Jacques Meyer Project design: Adrian Haagner, Piet Smit & Jacques Meyer Water remediation: Passive Treatment Technologies Using a sub-surface flow wetland on a rehabilitated decommissioned coal
Comparison of natural radioactivity removal methods for drinking water supplies: A review
Comparison of natural radioactivity removal methods for drinking water supplies: A review E. Esmeray, M. E. Aydin Selcuk University Environmental Engineering Department, Konya Turkey e-mail: [email protected]
Wastewater Reuse. Typical treated wastewater is:
Wastewater Reuse Most metal finishing industries have in-house wastewater treatment to economically dispose of the acids, alkali, oils, and dissolved metals in the rinse water and occasional tank solution
Krishna (Dist), Andhra Pradesh, India. Krishna (Dist). Andhra Pradesh, India *E-mail: [email protected]
http://www.rasayanjournal.com Vol.3, No.2 (2010), 341-346 ISSN: 0974-1496 CODEN: RJCABP A SURVEY ON FLUORIDE CONCENTRATION IN DRINKING WATER OF TIPPARTHY REVENUE SUB-DIVISION, NALGONDA DISTRICT, ANDHRA
How To Water System
Mid-Monroe Water System: Soluble Iron and Manganese Removal via Oxidation & Filtration Daniel Rickard, P.E. Engineering Project Manager Pennsylvania-American Water Company Who Is American Water We are
Evaluation of Alternatives to Domestic Ion Exchange Water Softeners. Mara Wiest Dr. Peter Fox Dr. Lee Wontae, HDR Tim Thomure, HDR
Evaluation of Alternatives to Domestic Ion Exchange Water Softeners Mara Wiest Dr. Peter Fox Dr. Lee Wontae, HDR Tim Thomure, HDR April 26, 2011 OUTLINE Water Quality and reuse in the Southwest US Ion
TRADITIONAL AND HOUSEHOLD WATER PURIFICATION METHODS OF RURAL COMMUNITIES IN DEVELOPING COUNTRIES
TRADITIONAL AND HOUSEHOLD WATER PURIFICATION METHODS OF RURAL COMMUNITIES IN DEVELOPING COUNTRIES S. Vigneswaran Faculty of Engineering, University of Technology, Sydney, Australia M. Sundaravadivel Graduate
Iron and manganese are two similar elements
L-5451 2-04 Drinking Water Problems: Iron and Manganese Mark L. McFarland, Associate Professor and Extension Soil Fertility Specialist Monty C. Dozier, Assistant Professor and Extension Water Resources
Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater
Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters
Coagulation and Flocculation
Coagulation and Flocculation Groundwater and surface water contain both dissolved and suspended particles. Coagulation and flocculation are used to separate the suspended solids portion from the water.
Environmental Technology March/April 1998
Treating Metal Finishing Wastewater Sultan I. Amer, Ph.D. AQUACHEM INC. Environmental Technology March/April 1998 Wastewater from metal finishing industries contains high concentrations of contaminants
LANDSCAPING AQUA SPORT. Rainwater treatment using filter substrate channel. DIBt approval applied for
CIVILS LANDSCAPING AQUA SPORT Drainfix Clean Rainwater treatment using filter substrate channel DIBt approval applied for CIVILS LANDSCAPING AQUA SPORT Drainfix Clean Application areas For the treatment
Saudi Aramco Project Development
Saudi Aramco Project Development Wastewater Treatment Facilities Jeddah Refinery And Marine Area December 2007 Facilities Planning Dept. OBJECTIVE: Provide an overview of the complexities of developing
Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water
technical article Document Ref: 0411001-NFPT-text-RevG Status: Re-issued to Elsevier Science Company: Amiad Filtration Systems Limited Issue Date: 10 February 2006 Copy Deadline: 10 February 2006 Publication:
Strength and Workability Characteristics of Concrete by Using Different Super Plasticizers
International Journal of Materials Engineering 12, 2(1): 7-11 DOI: 1.923/j.ijme.11.2 Strength and Workability Characteristics of Concrete by Using Different Super Plasticizers Venu Malagavelli *, Neelakanteswara
Treatment of Arsenic Residuals from Drinking Water Removal Processes
EPA/6/R/33 June 2 Treatment of Arsenic Residuals from Drinking Water Removal Processes by Michael J. MacPhee Gail E. Charles David A. Cornwell Environmental Engineering & Technology, Inc. Newport News,
CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM
CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM OTCO Water Workshop March, 2011 Frank Woyma Plant Manager Nick Pizzi Vice-President EE&T ENVIRONMENTAL ENGINEERING & TECHNOLOGY, INC. Objectives Review the
4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES
4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES Sl. No. Contents Preamble 4.1 Aim 4.2 Introduction 4.2.1 Environmental Significance 4.3 Principle 4.4 Materials Required 4.4.1 Apparatus Required 4.4.2 Chemicals
COST AND PERFORMANCE REPORT
COST AND PERFORMANCE REPORT Pump and Treat of Contaminated Groundwater at the United Chrome Superfund Site Corvallis, Oregon September 1998 Prepared by: SITE INFORMATION Identifying Information: United
DURABILITY OF MORTAR LININGS IN DUCTILE IRON PIPES Durability of mortar linings
DURABILITY OF MORTAR LININGS IN DUCTILE IRON PIPES Durability of mortar linings I. S. MELAND SINTEF Civil and Environmental Engineering, Cement and Concrete, Trondheim, Norway Durability of Building Materials
HEXAVALENT CHROMIUM REMOVAL FROM INDUSTRIAL WATSEWATER BY CHEMICAL PRECIPITATION METHOD
HEXAVALENT CHROMIUM REMOVAL FROM INDUSTRIAL WATSEWATER BY CHEMICAL PRECIPITATION METHOD Dr. C.R.Ramakrishnaiah P.G-Environmental Engineering Dept of Civil Engineering, B.M.S. College of Engineering Bull
Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies
Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies Yasar Avsar 1, Hussein Tarabeah 2, Shlomo Kimchie 3, Izzet Ozturk 4, Hadi Naamneh 2 1 Yildiz Technical
REMOVAL OF ANTIMONY FROM WATER BY SORPTION MATERIALS
2008/2 PAGES 1 6 RECEIVED 15.3.2008 ACCEPTED 26.4.2008 J. ILAVSKÝ REMOVAL OF ANTIMONY FROM WATER BY SORPTION MATERIALS JÁN ILAVSKÝ, PhD. Assistant Professor at the Department of Sanitary and Environmental
CHEMICAL PRECIPITATION: WATER SOFTENING
CHEMICAL PRECIPITATION: WATER SOFTENING Submitted to: Dr. Hashsham Research Complex Engineering Department of Civil and Environmental Engineering Michigan State University East Lansing, MI 4884 Authors
Available online at www.scholarsresearchlibrary.com. Scholars Research Library. Archives of Applied Science Research, 2011, 3 (1): 175-179
Available online at www.scholarsresearchlibrary.com Scholars Research Library Archives of Applied Science Research, 2011, 3 (1): 175-179 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-508X
Florida Department of Environmental Protection
Florida Department of Environmental Protection Background Mobile vehicle and equipment washing involves washing at a location where vehicles are based (such as a trucking company, warehouse, bus station,
CERTIFICATION TO OPERATE WATER AND WASTEWATER TREATMENT SYSTEMS APPLICATION INSTRUCTIONS
COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION STATE BOARD FOR CERTIFICATION OF WATER AND WASTEWATER SYSTEMS OPERATORS CERTIFICATION TO OPERATE WATER AND WASTEWATER TREATMENT SYSTEMS
Removal of ammonia by natural clay minerals using fixed and fluidised bed column reactors
Removal of ammonia by natural clay minerals using fixed and fluidised bed column reactors M.S. Çelik*, B. Özdemir*, M. Turan**, I. Koyuncu**, G. Atesok* and H.Z. Sarikaya** * Istanbul Technical University,
Attachment G-1: Pit Latrine Diagram. Fig E.1a: Pit Latrine. Fig E.1b: Plan View of Twin Pits
Attachment G-1: Pit Latrine Diagram Fig E.1a: Pit Latrine Fig E.1b: Plan View of Twin Pits Fig E.1c: Section of a water-sealed pan Fig E.1d: 3D view of Overflow Pipe Fig E.1e: 2D view of Overflow Pipe
Practice Tests Answer Keys
Practice Tests Answer Keys COURSE OUTLINE: Module # Name Practice Test included Module 1: Basic Math Refresher Module 2: Fractions, Decimals and Percents Module 3: Measurement Conversions Module 4: Linear,
Natural and Advanced Treatment Systems for Wastewater Management at Municipal Solid Waste Disposal Site in Developing Countries
Natural and Advanced Treatment Systems for Wastewater Management at Municipal Solid Waste Disposal Site in Developing Countries C. Chiemchaisri Department of Environmental Engineering, Kasetsart University
ION EXCHANGE RESINS INTRODUCTION
ION EXANGE RESINS Ion exchange resins are polymers that are capable of exchanging particular ions within the polymer with ions in a solution that is passed through them. This ability is also seen in various
Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors
s Control Analysis Fabrication A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors Eductors Ensure Thorough Mixing to Improve Product Quality and Reduce Maintenance Time Tank mixing eductors
Swamp Area Passive Treatment System Kettle Creek Watershed, Clinton County, PA
Swamp AMD Chemistry Swamp Area Passive Treatment System Kettle Creek Watershed, Clinton County, PA A Technical Report for Trout Unlimited and the Kettle Creek Watershed Association Prepared by Hedin Environmental
Chemical Decontamination and Fluid Handling Services
Chemical Decontamination and Fluid Handling Services Westinghouse is a global industry expert in decontamination and fluid handling processes, with proven abilities in decontamination and remediation work.
Subject: Technical Letter 22 April 1977 Removal of Water Supply Contaminants -- Copper and Zinc
STATE OF ILLINOIS Department of Registration and Education JOAN G. ANDERSON DIRECTOR. SPRINGFIELD BOARD OF NATURAL RESOURCES AND CONSERVATION JOAN G. ANDERSON CHAIRMAN BIOLOGY THOMAS PARK CHEMISTRY H.
Chemical nutrient analysis of different composts (Vermicompost and Pitcompost) and their effect on the growth of a vegetative crop Pisum sativum
Available online at www.pelagiaresearchlibrary.com Asian Journal of Plant Science and Research, 2011, 1 (1):116-130 Chemical nutrient analysis of different composts (Vermicompost and Pitcompost) and their
STATE OF VERMONT AGENCY OF NATURAL RESOURCES DEPARTMENT OF ENVIRONMENTAL CONSERVATION WASTE MANAGEMENT DIVISION SOLID WASTE MANAGEMENT PROGRAM
STATE OF VERMONT AGENCY OF NATURAL RESOURCES DEPARTMENT OF ENVIRONMENTAL CONSERVATION WASTE MANAGEMENT DIVISION SOLID WASTE MANAGEMENT PROGRAM Solid Waste Management Program Waste Management Division 103
TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa
TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa Tallinn is the capital of Estonia. It has approximately 450,000 inhabitants and the town area is about 150 km 2. Tallinn Water Ltd., owned by the City
A Low Cost Chemical Remediation Technology for Heavy Metals in Shipyard Stormwater. SBIR Topic N06 133
A Low Cost Chemical Remediation Technology for Heavy Metals in Shipyard Stormwater SBIR Topic N06 133 1 Normal Ave, CSAM RI 121A Montclair, NJ 07043 973 655 7385 SIROM TECHNOLOGY SIROM has developed a
Characterizing Beauty Salon Wastewater for the Purpose of Regulating Onsite Disposal Systems
Characterizing Beauty Salon Wastewater for the Purpose of Regulating Onsite Disposal Systems Fred Bowers 1,2, Ph.D. New Jersey Department of Environmental Protection Division of Water Quality August 14,
Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media
Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media ASME Research Committee Power Plant and Environmental Chemistry Overland Park, Kansas April 2-4, 2007 Prepared by: W. H. Stroman Primary
Specifications For Rehabilitation Hudson #1A Hudson #2 Foster Island Well #41
Specifications For Rehabilitation Hudson #1A Hudson #2 Foster Island Well #41 ITEM #6 1) Scope of Work The scope of this proposal is: Hudson Street Well #1A and Hudson Street Well #2 - clean and rehabilitate,
Evaluation of Site-Specific Criteria for Determining Potability
Evaluation of Site-Specific Criteria for Determining Potability and Cleanup Goals for Impacted Groundwater This paper presents considerations used to evaluate site-specific criteria for determining groundwater
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
Type of Sewer Systems. Solomon Seyoum
Type of Sewer Systems Solomon Seyoum 0 Learning objectives Upon completion of this lecture, the participants will be able to differentiate between types of sewer systems and discuss different aspects of
Guidelines For Sealing Groundwater Wells
Guidelines For Sealing Groundwater Wells Government of Newfoundland and Labrador Department of Environment and Conservation Water Resources Management Division Government of Newfoundland and Labrador Department
Residuals Management Somersworth Drinking Water Treatment Facility. Ian Rohrbacher, Treatment Operator IV
Residuals Management Somersworth Drinking Water Treatment Facility A HISTORICAL OVERVIEW OF SURFACE WATER TREATMENT RESIDUALS HANDLING Ian Rohrbacher, Treatment Operator IV Background We are a Grade III
DATA COLLECTION FOR DESIGN OF WASTEWATER TREATMENT FACILITIES
United States Agency for International Development Ministry of Water Resources and Irrigation LIFE Integrated Water Resources Management Task Order No. 802 EPIQ II: Contract No. EPP-T-802-03-00013-00 Global
How To Conduct An Environmental Impact Assessment
Proposed Terms of Reference for EIA studies 1. Introduction The proposed expansion of Bulk Drugs & Intermediates manufacturing unit by M/s. Sri Krishna Pharmaceuticals Limited (Unit V). is located at Plot
Routine Maintenance and Inspection
THE CORPORATION OF THE VILLAGE OF WARFIELD POLICY TITLE: Sanitary Sewer Operations POLICY: #5435 PURPOSE: This policy is to provide the Village of Warfield s procedures for maintaining its sanitary sewer
WASTE WATER TREATMENT for surface treatment applications
WASTE WATER TREATMENT for surface treatment applications Effluent an important cost factor Effluent cannot be avoided Water and compound are essential for vibratory mass finishing. During the finishing
SOURCE WATER PROTECTION DRINKING WATER SYSTEMS ISSUES EVALUATION
SOURCE WATER PROTECTION DRINKING WATER SYSTEMS ISSUES EVALUATION OXFORD COUNTY PUBLIC WORKS DEPARTMENT OCTOBER 2009 TABLE OF CONTENTS 1. INTRODUCTION...1 1.1. CLEAN WATER ACT AND THE ISSUES IDENTIFICATION/EVALUATION
MNIT Jaipur and University of Illinois Partnership Provides International Service-Learning Opportunities for LINC Students
MNIT Jaipur and University of Illinois Partnership Provides International Service-Learning Opportunities for LINC Students By Valeri Werpetinski, Shikhank Sharma, and Rohit Goyal An innovative educational
7. Chemical Waste Disposal Procedures
7. Chemical Waste Disposal Procedures Substances that Can and Cannot be Disposed of via Sink Drains or in Regular Solid Refuse Containers 1. It is prohibited to pour down a sink or floor drain, or place
Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains
1 P age Module 7: Hydraulic Design of Sewers and Storm Water Drains Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains 2 P age 7.1 General Consideration Generally, sewers are laid at steeper
Removing Heavy Metals from Wastewater
Removing Heavy Metals from Wastewater Engineering Research Center Report David M. Ayres Allen P. Davis Paul M. Gietka August 1994 1 2 Removing Heavy Metals From Wastewater Introduction This manual provides
Solar Desalination Using Distillation
Solar Desalination Solar Desalination Using Distillation S&T August Proposal 28, 2015 No. 4850 San Diego, CA USA Mitch Haws Project Manager Water Agreements Planner Program Development Division Phoenix
Septic System Owner s Manual
Septic System Owner s Manual Sponsored by: copyright 2013 No part of this publication may be reproduced without our consent. www.callbrownies.com Brownie s Septic and Plumbing has provided quality service
