PROFIBUS Junctions, Connectors, Accessories
|
|
|
- Rebecca Singleton
- 9 years ago
- Views:
Transcription
1 Contents Data heet PROFIU Junctions, Connectors, ccessories Data heet Rev. D PROFIU Junctions, Connectors, ccessories Ethernet Operate Engineer Control PROFIU DP Linking Device PROFIU P PROFIU P Remote I/O F Field T F PROFIU P Junctions Connectors ccessories PROFIU DP / P ccessories PROFIU DP Junctions Connectors ccessories
2 PROFIU Junctions, Connectors, ccessories The PROFIU P T-Connectors are available as tandard and Ex(Haz.) version. They are used for coupling 1 up to 4 transmitters to the P trunk via spurs. The spurs can optionally be connected by an M12 connection or directly via the EMC cable gland. Non-interrupted U operation when exchanging or extending a P transmitter Easy to use Low installation costs External grounding cable Pressure-compensation element EMC cable gland Tension spring connection luminium (standard) housing Non-Ex design (integrated bus termination, switchable) Ex(Haz.) design acc. to TEX (external bus termination with NPZ100-EX) NPJ120-NO, NPJ130-NO, NPJ420-NO, NPJ460-NO PROFIU P Junctions - Non-Ex version Recommendation of mounting hield is connected to the enclosure via the EMC cable glands. Thread the cable gland onto the seal, on the unprepared fieldbus cable. trip fieldbus cable here Fieldbus cable hielding Draw back the shielding braid 8 over the sheath of the fieldbus cable Use ferrules! M00694 Technical data Temperature range Operating temperature Type of protection Material of housing urface PROFIU P connection Cable bushing Clamping area Measuring instrument connector M12 x 1, 4-pin Installation advice Torques M16 cable gland on housing Coupling ring M16 cable gland Housing lid External earthing cable C IP 66 High-quality aluminium alloy (L-i 12) tove-enamelled RL 7001 Tension spring mm 2 EMC cable gland M mm contacts brass, surface CuZnu 6.25 Nm 4.5 Nm Nm Nm M
3 PROFIU Junctions, Connectors, ccessories NPJ120-NO PROFIU P Junction Non-Ex version, with bus termination The Transmitter (spur, 1-way) are connected using M12 connection 58 off on R1 C1 ocket M12 / P code Wire bridge us terminator 100R off on R1 C1 1uF 50Vdc us terminator 64 off on Enclosure P- (3) hield (4) P+ (1) (2) NPJ130-NO PROFIU P Junction Non-Ex version, with bus termination The Transmitter (spur, 1-way) are connected using cable bushing. M off on R1 C1 Wire bridge us Terminator 100R off on R1 C1 1uF 50Vdc 64 NPJ420-NO PROFIU P Junction Non-Ex version, with bus termination The Transmitter (spurs, 4-way) are connected using M12 connection us terminator P- (3) hielding(4) Enclosure P+ (1) off on (2) M off on R1 C1 125 ocket M12 / P code off on us terminator Wire bridge Enclosure us Terminator pluggable 100R 1uF 63V P- (3) hielding(4) P+ (1) (2) NPJ460-NO PROFIU P Junction Non-Ex version, with bus termination The Transmitter (spurs, 4-way) are connected using cable bushing M Wire bridge us Terminator pluggable 100R 1uF 63V off on R1 125 C1 us terminator off on Enclosure P- (3) hielding(4) P+ (1) (2) M00699 ll drawings not scaled! ll units in millimeter! 3
4 PROFIU Junctions, Connectors, ccessories NPJ120-EX, NPJ130-EX, NPJ420-EX, NPJ460-EX PROFIU P Junctions Ex area Ex (ia) TEX Recommendation of mounting hield is connected to the enclosure via the EMC cable glands. Thread the cable gland onto the seal, on the unprepared fieldbus cable. trip fieldbus cable here Fieldbus cable hielding Draw back the shielding braid 8 over the sheath of the fieldbus cable Use ferrules! M00694 Technical data Temperature range Operating temperature Type of protection Material of housing urface PROFIU P connection Cable bushing Clamping area Measuring instrument connector M12 x 1, 4-pin TEX Certification Installation advice Torques M16 cable gland on housing Coupling ring M16 cable gland Housing lid dapter / spur cable External earthing cable C IP 66 High-quality aluminium alloy (L-i 12) tove-enamelled RL 5015 Tension spring mm 2 EMC cable gland M mm Contacts brass, surface CuZnu II 2 G Ex ia IIC T Nm 4.5 Nm Nm Hand-tight Nm M
5 PROFIU Junctions, Connectors, ccessories NPJ120-EX PROFIU P Junction Ex area Ex (ia) TEX, without bus termination The Transmitter (spur, 1-way) are connected using M12 connection NPJ130-EX PROFIU P Junction Ex area Ex (ia) TEX, without bus termination The Transmitter (spur, 1-way) are connected using cable bushing us terminator: With external NPZ100-EX only ocket M12 / P code Enclosure Wire bridge P- (3) hielding(4) P+ (1) (2) M us terminator: With external NPZ100-EX only Enclosure Wire bridge P- (3) hielding(4) P+ (1) (2) M00702 NPJ420-EX PROFIU P Junction Ex area Ex (ia) TEX, without bus termination The Transmitter (spurs, 4-way) are connected using M12 connection 80 ocket M12 / P code Wire bridge P- (3) hielding(4) P+ (1) (2) 125 us terminator: With external NPZ100-EX only Enclosure M00703 NPJ460-EX PROFIU P Junction Ex area Ex (ia) TEX, without bus termination The Transmitter (spurs, 4-way) are connected using cable bushing 80 ocket M12 / P code Wire bridge P- (3) hielding(4) P+ (1) (2) 125 us terminator: With external NPZ100-EX only Enclosure M00703 ll drawings not scaled! ll units in millimeter! 5
6 PROFIU Junctions, Connectors, ccessories 6
7 PROFIU Junctions, Connectors, ccessories NPZ100-EX PROFIU P us Terminator Ex area Ex (ia) TEX Cable brown T II 2 GD T80 C IP 67 EEx ia IIC T6 EEx m II T6 Ui 17,5 V V Ii 380 m Ta: C KEM 01 TEX 1058 X 0344 Cable white M00705 Technical data Temperature range Operating temperature Type of protection Material of housing urface Connecting cable Cable bushing TEX Certification Installation advice Torques M16 adapter on the housing External earthing cable (if necessary) C IP 66 High-quality aluminium alloy (L-i 12) lack powder coated 2 x 0.14 mm 2 usadapter M16 II 2 G Ex ia IIC T6, II 2 G Ex m II T6 6.0 Nm Nm T II 2 GD T80 C IP 67 EEx ia IIC T6 EEx m II T6 Ui 17,5 V V Ii 380 m Ta: C KEM 01 TEX 1058 X ,5 30,5 M00706 ll drawings not scaled! ll units in millimeter! 7
8 PROFIU Junctions, Connectors, ccessories NPE100-NE PROFIU P Plug - M12, metal case, for Ex (Haz.) and Non-Ex area M00707 Technical data Poles Type of connection Cross-sectional area of connection Connecting thread Contact surface Type of protection Cable diameter Material of housing Inflammability to UL-94 Operating temperature Rated current per contact Nominal voltage Tracking resistance Volume resistivity to IEC512 part 2 Insulation resistance to IEC 512 part 2 Installation advice crew terminals Coupling ring PG cable gland Knurled screw 4 Poles, P code crewed mm 2 M12 CuZnu IP 67 Ø mm (PG9) CuZn V C V KC MΩ Ω Torques 0.4 Nm 4.0 Nm Hand-tight Dimensions Recommendation of mounting ca. 59 M12 x 1,5 Ø Use wire-end ferrules! Put isolating tube over the shield! ll drawings not scaled! ll units in millimeter! Frontview of plug and socket connector 2-pole fieldbuscable with shield (diameter about 8 mm ). Mounting by customer. Pressure screw Terminal clamp Washer hieldring with washer Wreath M16 x 0,75 Coupling sleeve M18 / M16 x 0.75 with mounted sleeve Wreath M18 Pins with screwed connection Wreath M18 outside Fixed screw Revolving screw Wreath M12 x 1 Male wire-colour red not used green bus P+ Pshield referenz equense of mounting: 1. Put the fieldbuscable through pressure screw, terminal clamp, washer, shieldring with washer. 2. Caution: Only for EMV! trip the fieldbuscable here, lay the shield over the shieldring. Cut the rest of the shield. hield can be connected, as drawing, with pin of the plug and socket connector. Prepare the cable as shown in the drawing. 3. Put prepared ends of the cable through the coupling sleeve. It s possible to use an isolating tube for the cable ends. Put shieldring with washer and shield into the coupling sleeve. Put washer, terminal clamp and pressure screw together. Then fix the pressure screw. 4. Fix the cable ends at the pins,, of he plug and socket connector. crew coupling sleeve and part with pins,, together. crew Positionmark! View to connecting piece PROTECTION REMRK TO DIN 34 MUT E OERVED M
9 PROFIU Junctions, Connectors, ccessories NPE300-NE PROFIU P ocket M12, metal case, for Ex (Haz.) and Non-Ex area M00709 Technical data Poles Type of connection Cross-sectional area of connection Connecting thread Contact surface Type of protection Cable diameter Material of housing Inflammability to UL-94 Operating temperature Rated current per contact Nominal voltage Tracking resistance Volume resistivity to IEC512 part 2 Insulation resistance to IEC 512 part 2 Installation advice crew terminals Coupling ring PG cable gland Knurled screw 4 Poles, P code crewed mm 2 M12 CuZnu IP 67 Ø mm (PG9) CuZn V C V KC MΩ Ω Torques 0.4 Nm 4.0 Nm Hand-tight Dimensions Recommendation of mounting 2-pole fieldbuscable with shield (diameter about 8 mm ). Mounted by customer. Pressure screw Terminal clamp Washer Recommendation of mounting: 1. Put the fieldbuscable through pressure screw, terminal clamp, washer, shieldring with washer. 2. Caution: Only for EMV! trip the fieldbuscable here and lay the shield over the shieldring. Cut the rest of the shield. hield can be connected, as drawing, with socket. Prepare the cable as shown in the drawing. ~ 54,5 Ø M12 x Put wire-end ferrule above the wires Put isolating tube over the shield! hieldring with washer Wreath M16 x 0,75 Coupling sleeve M18 / M16 x 0.75 with mounted sleeve Wreath M18 socket for screwed connection Wreath inside M18 Fixed screwl Revolving screw Wreath inside M12 x 1 3. Put prepared wires and perhaps isolated shield through the coupling sleeve. Put shieldring with washer and shield into the coupling shield. Put washer, terminal clamp and pressure screw together. Then fix the pressure screw. 4. Fix the cable ends at the socket pins,,. crew the coupling sleeve and the part with the sockets together. View to connecting piece crew Frontview of the socket Positionmark Male wire-colour red not used green bus P+ Pshield referenz Positionmark ll drawings not scaled! ll units in millimeter! PROTECTION REMRK TO DIN 34 MUT E OERVED M
10 PROFIU Junctions, Connectors, ccessories The PROFIU DP T-Connectors are available as luminium and tainless teel version. They are used for coupling one transmitter to the DP trunk via spurs. The spurs can optionally be connected by an M12 connection or directly via the EMC cable gland (for luminium version only). Non-interrupted U operation when exchanging a DP transmitter, as well as the last DP Transmitter by an active bus termination Easy to use Low installation costs External grounding cable Pressure-compensation element EMC cable gland (for aluminium version only) Tension spring connection tandard design (integrated bus termination) version as active bus termination (integrated power supply) luminum (standard) and stainless steel version NDJ120-NO, NDJ122-NO, NDJ130-NO, NDJ132-NO PROFIU DP Junctions luminium housing Recommendation of mounting hield is connected to the enclosure via the EMC cable glands. Thread the cable gland onto the seal, on the unprepared fieldbus cable. trip fieldbus cable here Fieldbus cable hielding Draw back the shielding braid 8 over the sheath of the fieldbus cable Use ferrules! M00694 Technical data Temperature range Operating temperature Type of protection Material of housing urface PROFIU DP connection Cable bushing Clamping area Transmitter connector M12 x 1, 5-pin, DP code upply voltage Term 24 V Charing rate at supply unit 24 V DC pur lines (L ) until 1500 kit/s! Installation advice Torques M16 cable gland on housing Coupling ring M16 cable gland dapter spur cable Housing cover External earthing connection IP 66 High-quality aluminium alloy (L-i 12) Enamelled RL 7001 Tension spring mm 2 EMC cable gland M mm Contacts brass, surface CuZnu 24 V DC +/- 10 % Ie = 10 m +15 % at bus utilisation until 32 participants per spur max m, max. over-all spur lines 6.60 m per DP segment 6.0 Nm 4.0 Nm 0.5 Nm Nm Nm M
11 PROFIU Junctions, Connectors, ccessories NDJ120-NO PROFIU DP Junction luminium housing, without bus termination The Transmitter (spur, 1-way) are connected using M12 connection ocket M12 / DP code 58 (1) -> (2) -> RxD/TxD-N (3) -> n.c 64 (4) -> RxD/TxD-P (5) -> hield / chirm NDJ122-NO PROFIU DP Junction luminium housing, with active bus termination (24 V DC) The Transmitter (spur, 1-way) are connected using M12 connection M00712 ocket M12 / DP code 58 (1) -> (2) -> RxD/TxD-N 64 (3) -> n.c (4) -> RxD/TxD-P (5) -> hield / chirm NDJ130-NO PROFIU DP Junction luminium housing, without bus termination The Transmitter (spur, 1-way) are connected using cable bushing M NDJ132-NO PROFIU DP Junction luminium housing, with active bus termination (24 V DC) The Transmitter (spur, 1-way) are connected using cable bushing M ll drawings not scaled! ll units in millimeter! M
12 PROFIU Junctions, Connectors, ccessories NDJ120-NO, NDJ122-NO PROFIU DP Junctions tainless steel housing Recommendation of mounting Pressurescrew, rubber washer must be put on the unprepared fieldbus cable tripped fieldbus cable hield will be connected with terminal to the housing Use ferrules! M00716 Technical data Temperature range Operating temperature Type of protection Material of housing urface PROFIU DP connection Cable bushing Clamping area Transmitter connector upply voltage Term 24 V Charing rate at supply unit 24 V DC pur lines (L ) until 1500 kit/s! Installation advice Torques M16 plastic screw cable gland on housing Coupling ring M16 cable gland dapter spur cable Housing cover External earthing connection C IP 66 tainless steel Polished Tension spring mm 2 Plastic screwed cable gland M mm M12 x 1, 5-pin, DP code 24 V DC +/- 10 % Ie = 10 m +15 % at bus utilisation until 32 participants Per spur max m, max. over-all spur lines 6.60 m per DP segment 3.75 Nm 2.5 Nm Hand tight Nm Nm M
13 PROFIU Junctions, Connectors, ccessories NDJ120-NO PROFIU DP Junction tainless steel housing, without bus termination The Transmitter (spur, 1-way) are connected using M12 connection ocket M12 / DP code (1) -> (2) -> RxD/TxD-N (3) -> n.c (4) -> RxD/TxD-P (5) -> hield / chirm NDJ122-NO PROFIU DP Junction tainless steel housing, with active bus termination (24 V DC) The Transmitter (spur, 1-way) are connected using M12 connection M00718 ocket M12 / DP code (1) -> (2) -> RxD/TxD-N (3) -> n.c (4) -> RxD/TxD-P (5) -> hield / chirm M007 ll drawings not scaled! ll units in millimeter! 13
14 PROFIU Junctions, Connectors, ccessories NDE100-NE PROFIU DP Plug M12, metal case, for Ex (Haz.) and Non-Ex area M00720 Technical data Poles Type of connection Cross-sectional area of connection Connecting thread Contact surface Type of protection Cable diameter Material of housing Inflammability to UL-94 Operating temperature Rated current per contact Nominal voltage Tracking resistance Volume resistivity to IEC512 part 2 Insulation resistance to IEC 512 part 2 Installation advice crew terminals Coupling ring PG cable gland Knurled screw 5 Poles, DP code crewed mm 2 M12 CuZnu IP 67 Ø mm (PG9) CuZn V C V KC MΩ Ω Torques 0.4 Nm 4.0 Nm Hand-tight Dimensions approx Ø 4 1 M12 x Frontview of plug and socket connector Male wire-colour not used green not used red bus RxD/TxD-N RxD/TxD-P shield referenz ll drawings not scaled! ll units in millimeter! PROTECTION REMRK TO DIN 34 MUT E OERVED M
15 PROFIU Junctions, Connectors, ccessories PROFIU DP connectors M00722 M00723 M00724 NDE210-NO NDE220-NO NDE230-NO pplication PROFIU DP connector PROFIU DP connector PROFIU DP connector Internet Connector 9-pos. D-U male connector 9-pos. D-U male connector 9-pos. D-U male connector Programming 9-pos. D-U female connector connector Terminal resistance 220 Ω / 390 Ω, resistor can be enabled externally 220 Ω / 390 Ω, resistor can be enabled externally Cable feed electable right or left, 35 electable right or left, 35 electable right or left, 35 Terminal blocks crew-cage crew-cage crew-cage Conductor crosssection olid: mm2, WG flexible: mm2, WG: olid: mm2, WG flexible: mm2, WG: olid: mm2, WG flexible: mm2, WG: Cable diameter Max. / min.: 8 mm (± 0.4 mm) Max. / min.: 8 mm (± 0.4 mm) Max. / min.: 8 mm (± 0.4 mm) us cable The connector is specified for cable type according to EN (see data sheet 10/ ) Temperature range C C C Degree of protection IP 40 IP 40 IP 40 Housing material, metal-plated, metal-plated, metal-plated Connector cycles > 200 > 200 > 200 Explosion protection FICO approval pprovals CE acc. LVD, UL, C-UL, C-ULus CE acc. LVD, UL, C-UL, C-ULus, C CE acc. LVD, UL, C-UL, C-ULus, C Protocol EI 485 (R 485) EI 485 (R 485) EI 485 (R 485) Max. aud rate 12 Mbit/s 12 Mbit/s 12 Mbit/s Nominal voltage U N 50 V DC 50 V DC 50 V DC Nominal current I N 100 m 100 m 100 m Function block diagram Dimensional diagram (NDE210-NO) Dimensional diagram (NDE230-NO) Construction (NDE230-NO) M00725 ll drawings not scaled! ll units in millimeter! 15
16 PROFIU Junctions, Connectors, ccessories NDZ411-NE Protecting Cap for all plugs M12, plastic M00726 NDZ413-NE Protecting Cap for all sockets M12, plastic M
17 PROFIU Junctions, Connectors, ccessories Ordering information PROFIU DP Junctions (IP 66 case) Catalog No. NDJ120-NO (856435) PROFIU DP T (one-way) junction, 2 x cable bushing and 1 x socket M12, without bus termination, aluminum housing NDJ122-NO (856433) PROFIU DP T (one-way) junction, 2 x cable bushing and 1 x socket M12, incl. active fix bus termination (24 V DC supply), aluminum housing NDJ130-NO (856434) PROFIU DP T (one-way) junction, 3 x cable bushing, without bus termination, aluminum housing NDJ132-NO (856429) PROFIU DP T (one-way) junction, 3 x cable bushing, incl. active fix bus termination (24 V DC supply), aluminum housing NDJ120-NO (871427) PROFIU DP T (one-way) junction, 2 x cable bushing (plastic) and 1 x socket M12 (tainless steel), without bus termination, stainless steel housing NDJ122-NO (871425) PROFIU DP T (one-way) junction, 2 x cable bushing (plastic) and 1 x socket M12 (tainless steel), incl. active fix bus termination (24 V DC supply), stainless steel housing PROFIU DP Connectors Catalog No. NDE210-NO ( ) PROFIU DP plug, 9-pos. U-D, IP 40, max. 12 Md, 35 cable outlet, without bus termination NDE220-NO ( ) PROFIU DP plug, 9-pos. U-D, IP 40, max. 12 Md, 35 cable outlet, incl. switchable bus termination NDE230-NO ( ) PROFIU DP plug, 9-pos. U-D, IP 40, max. 12 Md, 35 cable outlet, incl. switchable bus termination, programming connection U-D NDE100-NE (178479) PROFIU DP plug for cable, metal case, M12, for Ex and Non-Ex area PROFIU general - ccessories Catalog No. NDZ411-NE (178152) Preis und estellnummer pro Kappe Protecting cap for all plugs M12, plastic Packing unit 30 pcs., Order quantity: 30, 60, 90,...pcs. NDZ413-NE (945605) Preis und estellnummer pro Kappe Protecting cap for all sockets M12, plastic Packing unit 30 pcs., Order quantity: 30, 60, 90,...pcs. 17
18 PROFIU Junctions, Connectors, ccessories Ordering information PROFIU P Junctions (IP 66 case) Catalog No. NPJ120-NO (856406) PROFIU P T (one-way) junction, IP 66 case, 2 x cable bushing and 1 x socket M12, incl. switchable bus termination NPJ130-NO (856409) PROFIU P / FOUNDTION Fieldbus-H1 T (one-way) junction, IP 66 case, 3 x cable bushing, incl. switchable bus termination NPJ420-NO (856408) PROFIU P four-way junction, IP 66 case, 2 x cable bushing and 4 x socket M12, incl. switchable bus termination NPJ460-NO (856411) PROFIU P / FOUNDTION Fieldbus-H1 four-way junction, IP 66 case, 6 x cable bushing, incl. switchable bus termination NPJ120-EX (856415) PROFIU P T (one-way) junction, IP 66 case, 2 x cable bushing and 1 x socket M12, for the Ex (Haz.) area NPJ130-EX (856418) PROFIU P / FOUNDTION Fieldbus-H1 T (one-way) junction, IP 66 case, 3 x cable bushing, for the Ex (Haz.) area NPJ420-EX (856417) PROFIU P four-way junction, IP 66 case, 2 x cable bushing and 4 x socket M12, for the Ex (Haz.) area NPJ460-EX (856420) PROFIU P / FOUNDTION Fieldbus-H1 four-way junction, IP 66 case, 6 x cable bushing, for the Ex (Haz.) area NPZ100-EX (8606) PROFIU P / FOUNDTION Fieldbus-H1 bus termination for junction modules NPJ 0-EX, IP 66 case for the Ex (Haz.) area PROFIU P Connectors Catalog No. NPE100-NE (945564) P plug for cable, metal case, M12, for Ex (Haz.) and Non-Ex area NPE300-NE (842622) P socket for cable, metal case, M12, for Ex (Haz.) and Non-Ex area 18
19 PROFIU Junctions, Connectors, ccessories Ordering information PROFIU P Junctions (IP 20 modules) NGJ100-NE Fieldbus device coupler: Trunk line module For PROFIU P / FOUNDTION fieldbus-h1. For connecting the trunk line to the spur line modules, incl. overvoltage protection to the trunk line, supply voltage 10.6 / 16.7 up to 32 V DC, rated current 4.5 (trunk to trunk) / 1.0 (trunk to spur) IP 20, II 3G Ex n IIC T4 Gc, for Ex/Haz. (Zone 2) and Non-Ex area, incl. pluggable bus termination and DIN rail connector Dimensions (L x W x H) 99.1 x 17.5 x 70.4 mm Fieldbus device coupler: pur line module For PROFIU P / FOUNDTION fieldbus-h1. 2 channels, max. 12 modules per trunk line module, short circuit protection, supply voltage 9.3 V DC, output (spur line) 45 m (adjustable) IP 20, II 3(3)G Ex n [ic Gc] II T4 Gc, for Ex/Haz. (Zone 2) and Non-Ex area, Dimensions (L x W x H) 89.7 x 17.5 x 70.4 mm Fieldbus device coupler: pur line module intrinsically safe For PROFIU P / FOUNDTION fieldbus-h1. 1 channels, max. 12 modules per trunk line module, short circuit protection, supply voltage 10.0 V DC, output (spur line) 35 m (adjustable) IP 20, II 3(1)GD Ex n [ia Ga Da] IIC T4 Gc, for Ex/Haz. (Zone 2) and Non-Ex area, Dimensions (L x W x H) 89.7 x 17.5 x 70.4 mm Catalog No. ( ) 3KXN623100L0110 ( ) 3KXN623100L0120 ( ) 3KXN623100L0130
20 Contact us utomation GmbH ervice Instrumentation Kallstadter traße Mannheim, Germany Customer service center: +49 (0) * [email protected] * 14 cents/minute from German landlines, max. 42 cents/minute from mobiles. Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of. Rev. D Copyright 2012 ll rights reserved 3KXN640000R1001 ales ervice
PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. [email protected] - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.
egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
Plug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
Feed-through terminal block - SSK 110 KER-EX - 0502058
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
Mounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en
Mounting instructions Junction box VKK2R-8 DIGITAL VKK2R-8 DIGITAL 3 Contents Page Safety instructions... 4 1 Introduction and appropriate use... 7 2 Mechanical construction... 8 2.1 Mounting... 9 3 Electrical
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet 0/-8.5 EN FieldIT Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit)
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
HARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
Field bus connections Link structure CMS link structure CMS, B-design. Brochure
link structure CMS, B-design Brochure 2 link structure CMS, B-design Bus coupler with driver Optional field bus connection with I/O function (CMS), B-design Bus coupler with driver Field bus protocol:
High Power Connectors for Power Supply and Power Circuits
Introduction Silver Plated Power Contacts with Contact Springs for Maximum Performance in Exposed Applications The demand for shortest possible periods of machine shut-downs and assembly times requires
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment
B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space
PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning
HARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
TEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
Threaded resistance thermometer Model TR10-C, with protection tube
Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with protection tube WIKA data sheet TE 60.03 for further approvals see page 2 Applications Machine building, plant and
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
PROCESS AUTOMATION MANUAL R2-SP-N*
PROCE AUTOMATION MANUAL R2-P-N* egment Protectors R2-P-N* With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and
A good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B2325-1.0 en
HLC B1... HLC F1... HLC A1... HLC B1... HLC F1... Load cells Special features -- Hermetically sealed (IP68) -- Max. capacities: 220 kg... 10 t -- Stainless steel -- Low overall height -- Meets EMC/ESD
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
Aluminium Standard. Technical Data. Included in delivery
luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:
Electro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
CAPACITIVE LEVEL METERS CLM 36
CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by
Industrial circular connectors
Industrial circular connectors M 16 M 58 010 CONINVERS - M16 to M58 circular connectors for industrial applications CONINVERS GmbH, an independent company, is the specialist for M16 to M58 circular connectors
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
MNS is Switchgear System Technical Overview
Switchgear System Technical Overview Innovative Design ABB s innovative MNS is concept combines the long term experience, energy efficiency, grid reliability and industrial productivity of the well-known
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
TEIP11-PS I/P signal converter for standard signals. Measurement made easy
Change from one to tw o c olumns Data Sheet 10/18-0.10-EN Rev. C TEIP11-PS I/P signal converter for standard signals Measurement made easy Proven and reliable concept Compact design Small dimensions, low
SOURIAU s discrete wire sealing
SOURIAU s discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTO & UTS connectors with grommet garantie a discrete wire sealing
PBA series Piezo switches
Piezo switches Specifications UG1410 ushing diameter 16 mm, 19 mm or 22 mm Sealed to IP68 and IP69K (switches mounted on panel) Easy to clean metal surface Very long life expectancy Ring or dot illumination
400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
PROFIBUS Links & Coupler
Data Sheet DS/NDL-EN Rev. A PROFIBUS Links & Coupler Measurement made easy PROFIBUS DP/PA Segment coupler Segment coupler (compact) Motherboard for Gateways (simplex) Motherboard for Gateways (redundant)
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
type V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Plug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
7000 Series Buccaneer
The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Subminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
Now Available in Black Zinc Nickel
847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
3-Component Measuring System
Force 3-omponent Measuring System for utting Force Measurement During Turning Modular system for measurement of cutting forces when turning outside and inside diameters on turret lathes. Machine adapters
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T
Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Relative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the