Sika CarboDur Product Data Sheet
|
|
|
- Angelina Ray
- 9 years ago
- Views:
Transcription
1 Page 1 of 8 Product Data Sheet Sika CarboDur Heavy-Duty CFRP Strengthening System Description Heavy-duty CFRP strengthening system for reinforced concrete, masonry, stonework, steel, aluminum and timber. System components: CFRP plates Sikadur-30 adhesive for bonding reinforcement prestressing systems NEW! Uses As a result of intensive research work at the Federal Materials Testing and Research Centre (EMPA) in Dübendorf, it is now possible to make bonded reinforcement for reinforced concrete, masonry, stonework, steel, aluminum and timber structures with corrosion-resistant plates made of carbon fibre reinforced polymers (CFRP). Economically development work by Sika AG was made so that it is possible to apply the CarboDur system, after preparation of the surface, without any other installations. To strengthen structures for: Loading increase Increasing the live loads Increased traffic loads Installation of heavy machinery in industrial buildings Changes of building utilization Damage to structural parts Ageing of construction materials Steel reinforcement corrosion Vehicle impact Fire Earth quakes Serviceability improvement Decrease of deformation Stress reduction in steel reinforcement Crack width reduction Change in structural system Removal of walls or columns Removal of slab sections for openings Change of specifications Earth quakes Adjustment to changed design philosophy Design or construction defects Insufficient reinforcement Insufficient structural depth The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika s current knowledge and experience of the products when properly stored, Shandled and applied under normal conditions within their shelflife. In practice, the differences in materials, substrates and actual site conditions are such, that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users should always refer to the most recent issue of the Technical Data Sheet for the product concerned, copies of which will be supplied on request or can be accessed in the Internet under 1
2 Page 2 of 8 Advantages Low in weight Available in any length, no joints required Low overall thickness Easy to transport (rolls) Laminate intersections are simple Economical application - no heavy handling and installation equipment Very high strength Available in various moduli of elasticity Outstanding fatigue resistance High alkali resistance No corrosion Clean edges without exposed fibers General construction approval in many countries Test reports/ approvals EMPA, Report No /1, 1994: Static loading tests on concrete beams strengthened with EMPA, Report No , 1994: Testing the Sika roll-on process on voids by infrared thermography EMPA, Report No , 1994: Fire test with strengthened RC beams -EMPA, Report No e-1, 1999: Application of plates under dynamic load EMPA, Report No E/2, 1999: Fatigue and Failure Test B1/B2 EMPA, Report No /2, 1998: Testing of prestressed CarboDur CFRP plate, beam V1 UCSD, SSRP Report, 2000: Post-strengthening of concrete slabs with externally bonded CarboDur CFRP plates-analytical approach and design recommendation NTNV, Report No. R-9-00, 2000: Strengthening prestressed concrete beams with CarboDur CFRP plates Deutsches Institut für Bautechnik Z , 1997: General construction Authorisation for SOCOTEC, Rapport No. HX0823, 2000: Rapport d enquete technique / cahier des charges - / SikaWrap (French) Literature Bänziger H., Steiner W., 1989: Epoxy adhesives for load bearing jointing. Schweizer Baublatt No. 64, August Deuring M., 1993: (German) Strengthening reinforced concrete with prestressed composite fibre materials. Federal Materials Testing and Research Centre (EMPA), EMPA Report No. 224, Deuring M., 1994: CFRP laminates in the construction industry. Strengthening concrete structures. Swiss Engineer and Architect No. 26, 23. June Meier, U., 1994: (German) Strengthening structures with composite fibre materials. VDI Report No. 1080, 1994, Ps SIA/EMPA: (German) Reinforcement of structures with CarboDur-laminates. Documentation D 0128, Sika 1997 (German) Strengthening of structures with CFRP strips. Convention Okt./ Nov Kropf W., Meier H., 1999: (German) Reinforcement of existing timber constructions with CFRP-plates. SAH-Education Bearing bond constructions with timber, Nov. 1999, Weinfelden. Andrä H.-P., 1999: (German) Strengthening of bridges using bonded, prestressed carbon fiber plates. Bridge construction seminar, Bavarian Road Construction Administration, Kulmbach, September Seim W., Karbhari V., Seible F., 1999: (German) Post Strengthening of concrete slabs using Externally Bonded Fiber Reinforced Polymers. Beton- und Stahlbetonbau 94 (1999), No. 11 Meier H., 2000: (German) Reinforced structure with composite fibre materials: Examples of use. Specialist event Composite fibre materials for engineering structures: Changed utility and new buildings. TFB Wildegg, March
3 Page 3 of 8 Availability XS Tensile E-Modulus N/mm 2 Type Width [mm] Thickness [mm] Cross sectional area [mm²] XS XS XS XS S Tensile - E-Modulus N/mm² Type Width [mm] Thickness [mm] Cross sectional area [mm²] S S S S S S S S S S M (steel equivalent) Tensile - E-Modulus N/mm² Type Width [mm] Thickness [mm] Cross sectional area [mm²] M M M M M UH Tensile - E-Modulus N/mm² Type Width [mm] Thickness [mm] Cross sectional area [mm²] UH Packaging plates: - Cut to size according parts list in reusable packaging - Supply in rolls of 250m in reusable packaging Sikadur-30 adhesive: - Pre-dosed units (Comp. A+B) at 5 kg - Pallets at 400 kg (80 x 5 kg) - Not pre-dosed industrial packaging: Comp. A 30 kg pails, Comp. B 10 kg pails - Pallets at 560kg (14 x 30 kg Comp. A and 14 x 10 kg Comp. B) Colma Cleaner: - In 1 and 5 kg pails, 20 kg mini drum and 160 kg drum Sika Carbodur Rubber Roller: - sales unit 1 pce. Sika Mixing Spindle: - sales unit 1 pce. 3
4 Page 4 of 8 Technical Data plates Shelf life Base Colour Unlimited (no exposure to direct sunlight) Carbon fiber reinforced polymer with an Epoxy matrix. Black Fiber volumetric content > 70 % XS S M UH E-Modulus *(mean value) N/mm² N/mm² N/mm² N/mm² E-Modulus *(min. value) > N/mm² > N/mm² > N/mm² > N/mm² Tensile strength * (min. value) > N/mm² > N/mm² > N/mm² > N/mm² Mean value of tensile strength at break* N/mm² N/mm² N/mm² N/mm² (mean value) strain at break* (min. value) >1.35 % >1.70 % >1.35 % >0.45 % * Mechanical values obtained from longitudinal direction of fibers. Sikadur-30 adhesive for bonding reinforcement Appearance Comp. A: White paste Comp. B: Black paste Comp. A+B: Light grey when mixed Mix ratio Comp. A : Comp. B = 3 : 1 (parts by weight) Exact mixing ratio to be safeguarded by using scales. Consistency Shelf life Application temperature Density Pot life Open time Sag flow Comp. A + B mixed : creamy, pasty In original packing stored at + 5 C to + 25 C: 24 months from date of production. Substrate and ambient + 10 C to + 35 C kg/l (A+B) 120 minutes (at +10 C) 40 minutes (at +35 C) 30 minutes (at +35 C) 3-5 mm (at +35 C) 4
5 Page 5 of 8 Compressive strength (to EN 196) Development of compressive strength N/mm Hours N/mm Hours Shrinkage Glass transition temperature Heat distortion resistance (to ASTM D 648) Static E-modulus Adhesive strength (wet) 0.04 % +62 C Curing: HDT: 7d, +10 C : +36 C 7d, +35 C : +53 C 6h, +60 C +53 C 3h, +80 C +53 C N/mm² Concrete failure (approx. 4 N/mm²) Shear strength Thermal coefficient of expansion (to Sika) Concrete failure (approx. 15 N/mm²) per C (-10 C to +40 C) * Fédération Internationale de la Précontrainte Note The values given may vary according to the mixing intensity and amount of air entrained (through mixing). 5
6 Page 6 of 8 Pre-tensioned plates (For detailed information and application please contact your local Sika company) Uses Advantages Longitudinal and transversal strengthening of bridges Seismic strengthening of masonry and concrete walls Strengthening of industrial and commercial buildings and halls Strengthening in all climatic conditions Increase of durability simple prestressing of existing structural elements low weight for easy handling low loss of prestress due to higher initial tensile strain not bulky because of thin section comparable stress level for CFRP plates and prestressing steel no stress corrosion cracking risk non-corrodable tendon optimal use of the high mechanical strengths of the CFRP plates 30% to 50% less plates than non pre-tensioned. optimal price/performance ratio for strengthening of reinforced concrete increased serviceability: reduction of crack width, tensile steel strain and corrosion strengthening effect can also be "activated" for dead weight reduction of tensile strain of existing steel reinforcements possibility of structural strengthening at low substrate temperatures and high humidity without the need of heating plate thickness up to 2,4 mm Short end-anchors of the plates SYSTEMS: Sika LCII Sika-StressHead : V 914 V 624 Cross section: 126 mm2 144 mm2 Presstress load: 200 kn 220 kn Pretensioning tensile strain: 9.5 / 9.5 / Tensioning anchor: Leoba LCII StressHead 220 Notes on design General remarks Procedure for assessing the condition of the structure Verifications A -plate has no plastic deformation reserve. Therefore the maximum bending resistance of a strengthened section is reached when plate failure occurs during steel yield and before concrete failure. The mode of failure is influenced by the plate cross-section. To limit crack widths and deformation the yield point should not be reached in the reinforcing bars under service conditions. Any shear cracks which occur must be prevented from causing displacement on the strengthened surface and shearing off the laminate. Stress and deformation calculations can be made by the normal methods. They should be verified in accordance with standards SIA 160 (1989) and 162 (1989). Dimensions (geometry, reinforcement, evenness of surface to be strengthened), quality of existing construction materials, ambient climatic conditions, agreed conditions of service. Loading safety: Non-strengthened structure (with allowance for a reduced total safety factor > 1.0) Strengthened structure (with the mode of failure described above, check on the strains) Shearing of plate Anchorages Fatigue resistance:. Check on concrete and steel stresses Serviceability: Deformation (with average strains, assuming elastic behaviour of the structure and time-based strain changes in the concrete) Steel stresses (no plastic deformation in service conditions) Crack widths (by limiting the steel stresses under service conditions) 6
7 Page 7 of 8 Application Important notes Substrate Medium adhesive tensile strength of the prepared concrete substrate is 2.0 N/mm², min. 1.5 N/mm². The system must be protected from permanent exposure to direct sunlight. Maximum admissible service temperature is +50 C. When using Heating device together with Sikadur-30 LP it may be increased to max C. Max. substrate moisture content 4 %. Min. application temp C. Ambient and substrate temperature during application must be min. 3 C above dew point. The instructions in the Technical Data Sheet must be followed when applying Sikadur-30 adhesive. Reinforced concrete: Clean, free from grease and oil, dry, no loose particles or laitance. Preparation: Sandblast or grind. Timber, brickwork: Clean, free from grease and oil, no loose particles. Preparation: Sandblast, plane or grind. Steel: Clean, free from grease and oil, no rust Preparation: Sandblast or grind, Primer Icosit-277 or Sikagard-63N. After preparation, remove all dust from the surface with an industrial vacuum cleaner. The surface to be coated must be level, with steps and form work marks not greater than 0.5 mm. Planeness of substrate to be checked with a metal batten. Tolerance for 2 m length max. 10 mm. Mixing Sikadur-30 Pre-dosed packs: Add component B to component A and stir with a mixing spindle fitted to an electric low speed mixer (max. 500 rpm) to avoid entrapping of air. Mix thoroughly for about 3 minutes to uniform appearance. Then, pour the whole mix into a clean container and stir again for approx. 1 more minute at low speed to keep air entrapment at a minimum. Bulk packing, not pre-dosed: Stir the material well in the containers. Add the components in the correct proportion using a scale. Pour them into a suitable mixing container and stir correctly using an electric low speed mixer as indicated for ready to use pre-dosed packs. The pot life begins when the resin and hardener are mixed. It is shorter at high temperatures and longer at low temperatures. The greater the quantity mixed, the shorter the pot life. To obtain longer workability at high temperatures, the mixed adhesive may be divided into portions. Another method is to chill components A and B before mixing them. Application of Sika CarboDur CFRP-plates If there are large blowholes or honey combs on the concrete surface, these must first be filled with a repair mortar. The Sikadur-30 adhesive must be used as a bonding layer to ensure a good bond with the concrete substrate. As repair mortar use Sikadur-41 or Sikadur-30 adhesive, filled max. 1 : 1 by weight with Sikadur-501 quartz sand. Place the plate on a table and clean the blank side with Colma Cleaner using a white rag. Apply the Sikadur-30 adhesive with a roof shaped spatula onto the CarboDur laminate. Apply the well-mixed Sikadur-30 adhesive carefully to the properly prepared, dustfree substrate with a spatula to form a very thin layer. Within the open time of the adhesive, depending on temperature, place the coated Sika CarboDur plate onto the prepared concrete surface. Using a Sika rubber roller, press the plate into the epoxy adhesive until the material is forced out on both sides of the laminate. Remove surplus epoxy adhesive. Samples should be made up on site to check the adhesive used in respect of curing rate and final strength. Measure the compressive and flexural tensile strength after curing. Average Standard values are: Curing 7d at + 23 C - Compressive strength > 75 N/mm 2 - Flexural tensile strength > 35 N/mm 2 In case of plate intersections the first applied plate is to be degreased with Colma Cleaner. If more than one plate is bonded together, they have to be cleaned on both sides with Colma Cleaner (every contact plate-adhesive). Sikadur-330 is suggested in this case. 7
8 Page 8 of 8 If required plates may be protected with fire resistant material. When the Sikadur-30 adhesive has cured, the plate has to be checked for hollows by tapping lightly or impuls-thermography. The exposed plate-surface can be painted with a coating material such as Sikagard-550 W Elastic or Sikagard-ElastoColor W. Consumption Width of plate Sikadur mm 0.35 kg/m 60 mm 0.40 kg/m 80 mm 0.55 kg/m 90 mm 0.70 kg/m 100 mm 0.80 kg/m 120 mm 1.00 kg/m 150 mm 1.20 kg/m Depending on plane- and roughness of substrate as well as plate crossings, actual consumption of adhesive may be higher. Cleaning Clean tools immediately with Colma cleaner. Wash hands and skin thoroughly in warm soap water. Cured material can only be removed mechanically. Recommendations for plates Cutting Protection measures The cutting to length of plates is preferably done with a diamond cutting disk. During cutting of plates wear goggles and dustmasks with filter for finest dust, as well as one way gloves. Safety Instructions Sikadur-30 Safety precautions Ecology The product can cause skin irritation (dermatose)! Apply barrier cream to hands and unprotected skin before starting work. Wear protective clothing (gloves, safety glasses). In contact with eyes or mucous membranes rinse immediately with clean warm water and seek medical attention without delay. Uncured components are contaminating of water and may therefore not be discharged into drains, waterways or the ground. Leftovers of the Colma-Cleaner and Sikadur-30 must be disposed of according to local regulations. Toxicity Comp. A: Please observe indications on packing. Comp. B: Non-toxic. Transport Comp. A: Non-hazardous. Comp. B: 8/65 c), free quantity: 500 kg For particulars please demand the material safety data sheet. SSika Schweiz AG P.O. Box 1300 CH-8048 Zürich Phone Telefax [email protected] Sika - Construction Chemicals from Switzerland - For the World 8
Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests
Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS May 29, 2013 Revision B Structural Guideline for Design and Installation Holes in Composite Floor Slab Terminal 3, Departure Level
High-performance, 2-part epoxy anchoring adhesive
Product Data Sheet Edition 27/04/2009 Revision no: 0 Identification no: 01 04 02 06 001 0 000030-3+ -3+ High-performance, 2-part epoxy anchoring adhesive Construction Product Description Uses Solvent-free,
Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION
Sikadur-Combiflex REVISED JULY 2002 Sealing system for cracks and problem joints with large movements Construction DESCRIPTION USES ADVANTAGES The Sikadur-Combiflex joint sealing system consists of two
Shear Strengthening. Sika CarboDur Composite Systems
Solutions with Sika Systems Shear Strengthening Sika CarboDur Composite Systems Long term tested and approved systems High strength composite systems Corrosion resistant Easy application No maintenance
PRODUCT DATA SHEET Sika Cable System
PRODUCT DATA SHEET Corrosion protection for bridge cables of steel and galvanized steel PRODUCT DESCRIPTION The Sika Cable System consists of coating materials as well as a sealing respectively injection
Low viscosity, solvent free elastic adhesive for wood flooring
Product Data Sheet Edition 25/06/2012 Identification no: 01 05 02 01 250 0 000009 SikaBond -54 54 Wood Floor Low viscosity, solvent free elastic adhesive for wood flooring Construction Product Description
2-part Epoxy primer, levelling mortar and intermediate layer
Product Data Sheet Edition 07/08/2008 Identification no: 01 08 01 02 007 0 000004 2-part Epoxy primer, levelling mortar and intermediate layer Construction Product Description Sikafloor -161 is an economic,
Two component epoxy paste adhesive
Advanced Materials Araldite 2015 Structural Adhesives TECHNICAL DATA SHEET Araldite 2015 Two component epoxy paste adhesive Key properties Toughened paste Ideal for bonding GRP, SMC and dissimilar substrates
Two component epoxy paste adhesive. Ideal for bonding GRP, SMC and dissimilar substrates
Advanced Materials Araldite 2015 Structural Adhesives TECHNICAL DATA SHEET Araldite 2015 Two component epoxy paste adhesive Key properties Toughened paste Ideal for bonding GRP, SMC and dissimilar substrates
Black epoxy paste adhesive system
Advanced Materials Araldite 2031 Structural Adhesives Araldite 2031 Black epoxy paste adhesive system Key properties Thixotropic non slumping Toughened adhesive, resilient bond Suitable for metal and composite
WATERPROOFING OF WET ROOMS
WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof
APE T CFRP Aslan 500
Carbon Fiber Reinforced Polymer (CFRP) Tape is used for structural strengthening of concrete, masonry or timber elements using the technique known as Near Surface Mount or NSM strengthening. Use of CFRP
Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.
Advanced Materials Araldite AV 170 Structural Adhesives Araldite AV 170 One component epoxy adhesive Key properties Cures at 140-180 C Heat resistant to 120 C Very good peel strength Good chemical resistance
Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
SC2000 CEMENT BONDING PROCEDURES
Pg.1 SC2000 CEMENT BONDING PROCEDURES Widely recognized as the world s finest cold vulcanizing cement REMA SC2000 is the solution to your industrial bonding problems. By using REMA UTR20 hardener with
Chapter 5 Bridge Deck Slabs. Bridge Engineering 1
Chapter 5 Bridge Deck Slabs Bridge Engineering 1 Basic types of bridge decks In-situ reinforced concrete deck- (most common type) Pre-cast concrete deck (minimize the use of local labor) Open steel grid
2009-12-23 ICS: 93.160. Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics)
36888 ежглеяис тгс йубеямгсеыс (теувос еутеяо) 20091223 ICS: 93160 150114010801:2009 H HELLENIC CHNICAL SPECIFICATION (FRP ) Strengthening retrofitting of reinforced concrete structures by gluing of fibre
CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS
AN ERGONARMOR COMPANY TECHNICAL INFORMATION SPECIFICATION FOR INSTALLATION 07/11 SUPERSEDES 04/00 PAGE 1 OF 6 CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS 1. SCOPE 1.1 This specification
Elastic, 1-part-polyurethane, liquid waterproofing membrane
Product Data Sheet Edition 15.04.2008 Revision no.: 1 Identification no: 01 07 02 03 002 0 000005 Sikalastic -450 Elastic, 1-part-polyurethane, liquid waterproofing membrane Construction Product Description
Construction. Structural Strengthening with SikaWrap Fabric Systems
Construction Structural Strengthening with SikaWrap Fabric Systems Strengthening Fibers, SikaWrap Fabrics and Sikadur Resins Strengthening Fiber Types Three different main types of fibers are suitable
Wecryl Waterproofing System under surfacing supplied by others
Brief description The Wecryl waterproofing system allows a high-quality, seamless and crack-bridging waterproofing layer to be installed under loose-laid or bonded surfacing supplied by others (stone slabs,
Temperature C 10 15 23 40. Cure time to reach hours - - - - LSS > 1MPa minutes 20 12 8 2
Advanced Materials Araldite 2021 Structural Adhesives TECHNICAL DATA SHEET Araldite 2021 Two component toughened methacrylate adhesive system Key properties Rapid curing High peel strength Multi purpose
Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, 2016. Product Description
3 Scotch-Weld TM 1838 1838 1838-L Technical Data February, 2016 Description 3M TM Scotch-Weld TM s 1838 and are controlled flow products; Scotch-Weld 1838-L is flowable. These epoxy adhesives are two-part,
SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND.
SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. 623.10.1 Description. This work shall consist of preparing the surface,
Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form
Construction Product Data Sheet Edition 15/07/2013 Identification no: 01 07 05 04 001 0 000001 Sika 1 Pre-Bagged Structural Waterproofing System Product Description Pre-Bagged Structural Waterproofing
Technical Data Sheet February 2014
Scotch-Weld Technical Data Sheet February 2014 Product Description s are high performance, two-part acrylic adhesives that offer excellent shear, peel, and impact performance. These toughened products
ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.
Two-component flexible, waterproofing and protective cementitious grout. 1504-2 PI-MC-IR Technical features Two-component grout, based on cements, selected aggregates, special additives and synthetic polymers
Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013
Scotch-Weld TM Product Data Sheet Acrylic Adhesives Date: Supersedes: August 2013 Product Description 3M TM Scotch-Weld Acrylic Adhesives are high performance, twopart acrylic adhesives that offer good
Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated
Scotch-Weld TM Product Data Sheet DP410 Off-White Supersedes: October 2001 Product Description DP410 epoxy adhesive is a low flow, two-part epoxy based structural adhesive. It is designed for use where
SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY
BS 40 M6 MuCis mono SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY LE CE LE type: "expansive binder which allows the production of extremely fluid concrete
3-part cement and epoxy combination mortar for self-smoothing floor screeds of 3 to 7 mm
Product Data Sheet Edition 17/08/2011 Identification no: 02 08 02 01 002 0 000001 Sikafloor -82 EpoCem 3-part cement and epoxy combination mortar for self-smoothing floor screeds of 3 to 7 mm Construction
Mold Preventing I nterior System
interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal
Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)
Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Gyproc Plasters The cracks in cement sand plaster are an inherent feature which cannot be completely prevented but can only be controlled and
SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS
Fracture Mechanics of Concrete Structures Proceedings FRAMCOS-3 AEDIFICA TIO Publishers, D-79104 Freiburg, Germany SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS H.
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
Division 9. SignaFlor Pad and Pour Flooring System
Division 9 SignaFlor Pad and Pour Flooring System SPECIFICATIONS Page 1. General... 2 1.1 Description 2 1.2 Quality Assurance 2 1.3 Submittals 2 1.4 Delivery and Storage 3 1.5 Warranty 3 1.6 Working Conditions
(T indicates a Tropicalised version with extended workability. No change has been made to the formulation)
928 T (T indicates a Tropicalised version with extended workability. No change has been made to the formulation) High strength, non-shrink cementitious grout Description 928 T is a ready to use product
Tecnoepo Flooring System 185
Certificate ICMQ 1305-CPD-0808 Approved Standard EN 1504-2 prospect ZA.1f Direttive 89/106/CEE TECNOCHEM E LEED LEED Leadership Energy Environmental Design THE PRODUCTS: Primer TECNOFIX EP 110 Primer two-component
Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete
Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete Ming-Gin Lee 1,a, Yi-Shuo Huang 1,b 1 Department of Construction Engineering, Chaoyang University of Technology,Taichung
738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted 02-20-14)
POLYMERIC CONCRETE BRIDGE DECK OVERLAY (Adopted 02-20-14) Description The polymeric concrete bridge deck overlay shall consist of an epoxy polymer that acts together with special aggregate to form an overlay
Araldite LY 3505* / Hardeners XB 3403* / Hardener XB 3404-1* / Aradur 3405*
Advanced Materials Araldite * / Hardeners * / Hardener * / Aradur 3405* WARM CURING EPOXY SYSTEMS Araldite is an epoxy resin Hardeners, and Aradur 3405 are based on aliphatic polyamines APPLICATIONS PROPERTIES
Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14
Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318
Epoxy Crack Injection (the basics)
Epoxy Crack Injection (the basics) John Bors ChemCo Systems Introduction Overview of pressure crack injection Practical and technical issues Choose a primary repair technique Epoxy properties ChemCo Systems
SPECIAL NOTE FOR ASPHALT WATERPROOFING MIX FOR BRIDGE-DECK OVERLAYS AND ADJACENT APPROACHES
SPECIAL NOTE FOR ASPHALT WATERPROOFING MIX FOR BRIDGE-DECK OVERLAYS AND ADJACENT APPROACHES 1. DESCRIPTION. Asphalt Waterproofing Mix (AWM) is a highly elastomeric, polymermodified, impermeable asphalt
1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE
1..1 1.1.8 PRODUCTBLADEN SHEETS GT page 1 to 6 Rockpanel Structure is a very durable panel with a lightly textured finish, specially developed for use in cladding, fascia, soffit applications. The basic
Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
WATERPROOFING SikaFuko INJECTION HOSE SYSTEMS UNIQUE WATERPROOFING SOLUTIONS FOR CONSTRUCTION JOINTS
WATERPROOFING SikaFuko INJECTION HOSE SYSTEMS UNIQUE WATERPROOFING SOLUTIONS FOR CONSTRUCTION JOINTS SikaFuko PROVEN INJECTION HOSE SYSTEMS INTRODUCTION SikaFuko is a range of specially designed, hollow-core,
Mineral waterproof coating PCI Dichtschlämme
Mineral waterproof coating PCI Dichtschlämme 305 for basement walls, swimming pools and potable water tanks With official test certificate. FIELDS OF For indoor and outdoor use. For walls and floors. For
VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised
Page 1 of 6 instructions VC 104+ Rigid Grade / VC 104+ Rigid Grade Imagine / (for the rest of this document referred to as VC 104) can be applied to new and used trucks and trailers with painted rigid
Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)
Approved 402;2521 1 2521 zinc epoxy ^(ValidationDate). 1 Product description This is a two component polyamide cured zinc rich epoxy coating. It is a very high zinc dust containing product. It conforms
2-part epoxy textured roller and seal coat
Construction Product Data Sheet Edition 3 December 2014 Sikafloor -264 T 2-part epoxy textured roller and seal coat Product Description Uses Characteristics / Advantages Sikafloor -264 T is a thixotropic
Sikagard -203 W (Steridex)
Product Data Sheet Edition 03/10/2011 Identification no: 020807010010000001 Sikagard-203 W (Steridex) Single component, waterborne modified acrylic resin surface coating Product Description Uses Characteristics
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
SIKA AT WORK THE KAENG KRACHAN ELEPHANT HOUSE AT ZURICH ZOO
SIKA AT WORK THE KAENG KRACHAN ELEPHANT HOUSE AT ZURICH ZOO SIKA SYSTEMS FROM BASEMENT TO ROOF BASEMENT TO ROOF SOLUTIONS FOR ELEPHANT HOUSE AT ZURICH ZOO PROJECT DESCRIPTION The Kaeng Krachan Elephant
3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data March, 2002
3 Scotch-Weld TM Technical Data March, 2002 Product Description 3M TM Scotch-Weld TM 3532 B/A, 3535 B/A and 3549 B/A are two-component, polyurethane adhesives which cure at room temperature or with heat
3 Scotch-Weld TM. Epoxy Adhesive DP110 Translucent and Gray. Technical Data December, 2009
3 TM Technical Data December, 2009 Product Description 3M are two-part epoxy adhesives which combine a fast cure with flexibility. Features Controlled flow 20 minute handling strength Duo-Pak cartridge
INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA
INDUSTRIAL FLOORING INSTALLATION CHALLENGES James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA Abstract: Specifier's and contractors not only need to properly evaluate the
Polymeric membrane for roof waterproofing
Product Data Sheet Edition 09.2008 Revision no: 0 Identification no: 01 09 01 02 200 0 120000 Sarnafil TS 77-12 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics
ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials
ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials SECTION 03 92 50 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings,
BLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)
408;21800;21820;21740;21760;21840 1,2 408 unsaturated vinyl ester ^(ValidationDate). 1 Product description This is a glass flake reinforced unsaturated vinyl ester coating. It is an ultra high build, extremely
SIKA BRIDGE DECK WATERPROOFING SYSTEM SIKALASTIC -851 BRIDGE DECK WATERPROOFING SYSTEM
H A P A S Sika Services AG Speckstrasse 22 8330 Pfäffikon Switzerland Tel: +49 (0)711 8009-0 Fax: +49 (0)711 8009-1251 e-mail: [email protected] website: www.sika.com SIKA BRIDGE DECK WATERPROOFING
REPAIR AND STRENGTHENING OF HISTORICAL CONCRETE BRIDGE OVER VENTA RIVER IN LATVIA
1 REPAIR AND STRENGTHENING OF HISTORICAL CONCRETE BRIDGE OVER VENTA RIVER IN LATVIA Verners Straupe, M.sc.eng., Rudolfs Gruberts, dipl. eng. JS Celuprojekts, Murjanu St. 7a, Riga, LV 1024, Latvia e-mail:
Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)
Approved 735;739 1 735 phenolic/novolac epoxy ^(ValidationDate) 1 Product description This is a two component polyamine cured phenolic/novolac epoxy coating. It is a specially designed tank lining with
Concrete Repair. Applications and Procedures
Concrete Repair Applications and Procedures Objectives Identify what surface preparation is needed Identify typical modes of failure and testing methods How to choose the correct material for the repair
Detailing of Reinforcment in Concrete Structures
Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For
weber.floor 4660 Marine Elastic (EN)
Product advantages For marine and offshore installations inside in living quarters, wet areas and other light traffic areas - mainly foot traffic. Pumpable High elasticity Smooth surface Rapid drying and
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
Technical Notes 3B - Brick Masonry Section Properties May 1993
Technical Notes 3B - Brick Masonry Section Properties May 1993 Abstract: This Technical Notes is a design aid for the Building Code Requirements for Masonry Structures (ACI 530/ASCE 5/TMS 402-92) and Specifications
cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement
cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement Lafarge in North America The Lafarge Group is the world leader
SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING. 16.1 General...16-1. 16.2 Materials...16-1. 16.3 Equipment...
SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING TABLE OF CONTENTS 16.1 General...16-1 16.2 Materials...16-1 16.3 Equipment...16-1 16.4 Installation...16-2 16.4.1 Traffic Restrictions...16-2
Hilti HIT-HY 200 with rebar
Hilti HIT-HY 200 Injection mortar system Benefits Hilti HIT- HY 200-A 500 ml foil pack (also available as 330 ml) Hilti HIT- HY 200-R 500 ml foil pack (also available as 330 ml) Static mixer rebar BSt
BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:
412.1 DESCRIPTION BRIDGE FIELD PAINTING, REPAINTING, 412 This specification contains the requirements for the removal, containment, and disposal of existing paint on steel surfaces, preparing the steel
Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment
Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment Whatever You Rebuild, Repair and Protect...... Find the Right Solution! Henkel's Solutions for all Surface Engineering Needs
Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1. 212 F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)
Not approved 2063;2064 1,2 2063 ^(ValidationDate) 1 Product description This is a two component solvent free polyamine cured coating. It is a general purpose tank lining with good chemical resistance.
CA-48 TECHNICAL SPECIFICATION
CA-48 TECHNICAL SPECIFICATION SafeLane surface overlay Pavement Substrate A Cargill Deicing Technology Product Providing customers with deicing solutions that save lives and enhance commerce. Helping to
FM 300-2 FILM ADHESIVE
FM 3002 FILM ADHESIVE DESCRIPTION FM 3002 film adhesive is a cure version of Cytec Engineered Materials widely used FM 300 film adhesive. It delivers the same superior high temperature performance, toughness
GigaCrete Specification PlasterMax
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
Resurfacing Concrete. Page 1 of 5
Resurfacing Concrete Materials List QUIKRETE Concrete Resurfacer (No. 1131) (see calculator on page 5 for quantity needed) QUIKRETE Concrete and Stucco Wash (No. 8601) QUIKRETE Concrete Sealer (No. 8800)
PanelTack HM. for the bonding of SVK Ornimat SKG 08.08.056.02
PanelTack HM for the bonding of SVK Ornimat Product Simson PanelTack HM is a moisture curing, elastic adhesive based on SMP (Silyl Modified Polymer). PanelTack HM is solvent- and isocyanate free. s Bonding
Waterproofing construction Joints
WaterproofingSystems Waterproofing construction Joints Area waterproofing Backing rod KÖSTER Joint Sealant FS-H KÖSTER FS Primer Contents Basics Connective, loadable and resilient: Joints in building construction
Field Damage Inspection and Static Load Test Analysis of Jiamusi Highway Prestressed Concrete Bridge in China
Advanced Materials Research Vols. 163-167 (2011) pp 1147-1156 Online available since 2010/Dec/06 at www.scientific.net (2011) Trans Tech Publications, Switzerland doi:10.4028/www.scientific.net/amr.163-167.1147
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
SikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,
DESIGN OF SLABS Dr. G. P. Chandradhara Professor of Civil Engineering S. J. College of Engineering Mysore 1. GENERAL A slab is a flat two dimensional planar structural element having thickness small compared
kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.
kalox-pool draft 231 KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete. repairing refurbishing and finishing 8-30 C Trowel / Spray 4 mm kalox-pool EN 1504-2 MAIN FEATURES
How To Test A Base Axe
Scotch-Weld DP760 Product Data Sheet Updated : February 2009 Supersedes: June 2001 Product Description DP760 epoxy adhesive is a non-sag, two-part room temperature curing adhesive designed for use when
Roofing. Sarnafil S 327-15EL. Polymeric membrane for roof waterproofing. Product Description
Roofing Product Data Sheet Edition 02.2015 Identification no: 02 09 01 01 201 0 150000 Version no. 04 Sarnafil S 327-15EL Polymeric membrane for roof waterproofing Product Description Sarnafil S 327-15EL
INTERIM ADVICE NOTE 96 /07 Revision 1 GUIDANCE ON IMPLEMENTING RESULTS OF RESEARCH ON BRIDGE DECK WATERPROOFING
Interim Advice Note 96/07 INTERIM ADVICE NOTE 96 /07 Revision 1 GUIDANCE ON IMPLEMENTING RESULTS OF RESEARCH ON BRIDGE DECK WATERPROOFING Summary This interim advice note provides guidance on improving
Green Thread Product Data
Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using
Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps
Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning May 7th 2013: Dominique Deschamps Scope of the paper Presentation of the project Cause of cracks
Numerical modelling of shear connection between concrete slab and sheeting deck
7th fib International PhD Symposium in Civil Engineering 2008 September 10-13, Universität Stuttgart, Germany Numerical modelling of shear connection between concrete slab and sheeting deck Noémi Seres
PC-Concrete Injectable Concrete Anchoring and Repair System
PC-Concrete Injectable Concrete Anchoring and Repair System DESCRIPTION: PC-Concrete is a two component (1:1 ratio), 100% solids, high modulus, structural epoxy paste. PC-Concrete is a solvent free, no
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
DECLARATION OF PERFORMANCE
Flooring Declaration of Performance Edition 01.07.2013 Identification no. Version no. 01 EN 1504-2: 2004 08 0921 EN 13813: 2002 DECLARATION OF PERFORMANCE Declaration of performance 1. Product Type Unique