2 STRUCTURIX Film Systems GE exclusively offers a solution with all components designed to work together seamlessly, start to finish. In bringing you integrated film systems, we re assuring you improved quality and safety, greater ease, savings in time and costs and the peace of mind that comes with a proven, end-to-end solution. In offering you renowned STRUCTURIX film systems, we re providing you the films and solutions most widely used in industrial radiography. IMAGE QUALITY Agfa was a pioneer in recognizing the importance of monitoring film systems, ensuring better image quality performance. The result is higher quality and safety of the inspected equipment and components. PROVEN TRACK RECORD STRUCTURIX film systems are proven in the very demanding field of non-destructive testing. Our customers worldwide are enthusiastic about our extensive assortment of products featuring superior reliability and guaranteed intrinsic quality. COMPLIANCE INVESTMENT IN INNOVATION Due to continuous investments in R&D, STRUCTURIX film systems enjoy an excellent reputation. Improvement of the NDT film Systems meets your economical and environmental needs better than ever before. An example of our coitment is the introduction of our STRUCTURIX Eco Film Systems, rendering less chemistry consumption, higher film throughput and lower energy usage. The system has been awarded certification by BAM. Approach TO ENVIRONMENTAL POLICY The STRUCTURIX ECO System combines both economy in use and ecological responsibility. This advanced film system minimizes its impact on the environment with less chemistry consumption, higher film throughput and lower energy usage. Our film systems are fully compliant with standards issued by the independent German Federal Institute for Materials Research and Testing, BAM. This designation proves STRUCTURIX capability to not only produce consistently but also to invest in quality systems which control and measure system parameters. This assures compliance with the Industrial Film Systems Classification Standards.
3 STRUCTURIX Films Advantages The STRUCTURIX film family has two key advantages of great importance in non-destructive testing image quality and consistent rugged behavior. Both result from Agfa s advanced emulsion technology and ultramodern high-tech coating processes. Speed (Rel LogE) % % % Film Density Optimum Image Quality All STRUCTURIX films benefit from an Agfa emulsion breakthrough that provides increased contrast and maximum detail perceptibility. In fact, it results in the highest intrinsic defect recognition for each speed range. Even the smallest details can be interpreted with ease. The finished X-ray film has a high quality with a brilliant surface, and the image has a pleasant blue tint. Protective Coating Film Batches An important feature of the STRUCTURIX films is a special protective top coating resulting directly from Agfa s Split Antistress Layer (SAL) technology. This top coat gives the films unique high resistance to pressure, scratching and creasing. Another advantage of the top coat is that surface roughness has been optimized for problem free processing in automatic feeders such as the FEEDER.
4 Technological Axis of STRUCTURIX D family Optimization of Contrast STRUCTURIX Quality Rugged performance Better Image Quality Faster D D D D D D Speed Better Local Contrast Faster D D D Theoretical Maximum for linear detection Speed Contrast (signal) of all films is optimized to approach the maximum contrast for a linear detector (industrial X-ray Film), thereby optimizing image quality and perceptibility. An exception to the rule is D, a super linear detector, where image quality is optimized through more than linear (extremely high) contrast in combination with very low noise. D D D Split Anti-stress Layer Emulsion Layer Base Emulsion Layer Split Anti-stress Layer Cubic Grain Plus Matting Agent The emulsion coatings are covered by two separate antistress layers ( + ). To achieve a rugged surface, the top layer has received the matting agent. High image quality and perceptibility through optimization of the signal to noise ratio for every STRUCTURIX film. Consistent Production Quality STRUCTURIX films are manufactured in large quantities. To ensure they meet the most rigorous worldwide quality standards, they are produced at a single facility under tightly controlled conditions in an ultramodern coating room. Agfa s Total Quality Management approach, certified by the ISO label, is the foundation of the system leading to this exceptional performance in production consistency. People, production equipment, and organization all become one system, geared to consistency and continuous improvement. It s what we call the moving target quality philosophy. Moving target means that to meet the increasing needs of our customers, quality has to be built into our products, not by additional testing, but by design. Agfa s emulsion technology, for example, helps to provide a highly homogeneous emulsion over the total coating area. Not only do the STRUCTURIX films have outstanding quality, they also have an exceptionally high level of batch to batch uniformity. Consistent Processing Quality STRUCTURIX films have a reputation for providing consistent and excellent results over a wide range of operating conditions. The Cubic Grain Plus technology is at the base of this consistent stable behavior. The extremely narrow grain size distribution, in combination with the cubic shape, assures that all exposed grains (latent image) will simultaneously develop the same density over a wide range of processing conditions. Moreover, they will do so rendering the very high contrast that is responsible for the high image quality. Darkroom Light Sensitivity STRUCTURIX films may be exposed to darkroom safelight conditions longer without sensitometric fogging (ANSI PH.). This means that brighter safelight illumination can be used, resulting in more ergonomic and efficient working conditions.
5 Image Quality and Film System Classifications Every application and every object require a specific class of industrial radiographic film or film system class which includes complementary film and film processing. A New Film System Classification The introduction of the Industrial Film Systems Classification Standards EN -, ASTM E-, ISO - and JIS-K provides an important means to assign film systems to the appropriate film system class. These standards identify the various types of industrial X-ray film systems and classify them based on objectively quantified parameters that are the foundation of film imaging performance. The standards for control of film processing EN - and ISO - provide the means to control the processing at the processor user level. The objective is to make sure that a classified system will produce the expected capabilities in daily use. As a result of being able to objectively determine the performance of a specific Film System (Film + Chemistry + Processing), film radiography remains the number one and most widely used NDT technique. The classification system classifies a film inclusive of film processing (type and chemicals). This illustrates the importance of processing in relation to imaging. The parameters are: G (contrast) Net density: D = G (contrast) Net density: D = D (noise) Net density: D = G/σD Net density: D = These parameters are selected based on the insight into imaging theory applied to the industrial X-ray film systems. G is a measure of the signal gain factor and σd indicates the noise, so that G/σd represents the signal/ noise ratio. In the context of growing quality awareness, the new perception of film system classification, described in EN, ASTM, ISO and JIS-K, gradually became norm for the industry. Technical Specifications Image Quality & Film System Classes A/Automatic Gradient G σd G/σd ISO SPEED DOSE m Type CEN EN - ASTM E - ISO - JIS- K D C special C T D C I C T D C I C T D C I C T D C II C T D C III C T Type CEN ASTM E - ISO - Chemicals G /G - development iersion time : sec. Developing temperature: C DENS= DENS= DENS= DENS= S D = D C special C D C I C D C I C D C I C D C II C D C III C Gy B/Manual Type CEN ASTM E - ISO - Chemicals G /G - development iersion time : 00 sec. Developing temperature: 0 C Gradient G σd G/σd ISO SPEED DOSE m Gy DENS= DENS= DENS= DENS= S D = D C special C D C I C D C I C D C I C D C II C D C III C
6 BAM Certification ISO Certification Agfa was the first company in the world that can boast certification by BAM, the German Federal Institute for Materials Research and Testing. In addition to semi-annual product testing (design approval) and round robin tests recognizing the competence of the Agfa film lab, the certification process involves a quarterly production monitoring and an annual audit at the Agfa plant. The results are recorded in the corresponding certificates. The most coonly used STRUCTURIX film systems based on the film types D, D and D combined with G developer and G fixer are BAM certified. The German Federal Institute BAM conducted a thorough study and awarded the STRUCTURIX Eco Film System ( min. cycle) the certificate of compliance to International Film System Classification Standards. GE s approach to quality control in the NDT industry At GE s Inspection Technologies business, we contend that obtaining an ISO certificate is only the beginning. Agfa was the first radiographic film manufacturer to achieve ISO certification for its STRUCTURIX films in 0. Since then, we have continued the legacy of quality, assuring you that our entire film system films, chemistry and equipment is produced under a strict Quality Management System approved to ISO 000. It s your guarantee of the superior quality of GE Measurement & Control products.
7 Characteristics and Applications STRUCTURIX D Extremely fine grain film with very high contrast. Ideal for exposures requiring the finest possible detail rendering. STRUCTURIX D Ultra fine grain film with very high contrast. This film obtains a very high detail perceptibility, which meets the requirements of the most critical NDT applications. For exposure with lead screens, using either X-ray, gaa rays or radiation from megavolt equipment. STRUCTURIX D Extra fine grain film with very high contrast. Suitable for a wide variety of critical applications. For exposure with lead screens, using either X-ray, gaa rays or radiation from megavolt equipment. STRUCTURIX D Very fine grain film with high contrast. Excellent for visualization of discontinuities. This film is intended for use with lead screens, using either X-ray or gaa rays. STRUCTURIX D Fine grain film with high contrast and high speed. Designed for direct exposure or with lead screens. For exposure with lead screens, using either X-ray or gaa rays. STRUCTURIX D Medium grain film with high contrast and very high speed. Suitable for a variety of applications. This film can be used for direct exposure or with lead screens. It gives good image quality with short exposure times. If even higher speed is required, fluorescent screens, in combination with F (not D), should be used. STRUCTURIX Wide Latitude films The wide latitude films are specially designed for in-house radiography and to inspect wide range thickness objects such as castings. STRUCTURIX DW An extra fine grain film with medium contrast and very high speed. The film can be used for direct exposure techniques or with lead screens. STRUCTURIX DW A high contrast, fine grain film with medium contrast combining good image quality and wide latitude. Electronic components Composite materials Castings (light metals and alloys) Multiple film techniques Electronic components Composite materials Castings Very high quality welds Nuclear quality Aerospace and aircraft industry Multiple film techniques Electronic components Composite materials Castings Very high quality welds Defense and nuclear industry Aerospace and aerospace industry Multiple film techniques Welding Castings Shipbuilding Aerospace and aircraft industry Multiple film techniques Welding Castings Shipbuilding Aerospace and aircraft industry Multiple film techniques Welding and casting Defense industry Aerospace and aircraft industry Composite materials Multiple film techniques Concrete and heavy construction work Castings Multiple film techniques Castings and other multi-thickness objects Ferrous and non ferrous castings Non-critical welds All non-classified materials inspection
8 Performance Characteristics Sensitometric Curves Sensitometric Curves D D D D D D D s.c Blue-base Log. rel. exp Density STRUCTURIX D, D s.c., D, D, D, D, D Exposure and processing parameters: 00, Pb screens, autom. proc., min. cycle, devel G, C Relative Exposure Factors Type 00 Se Ir Co 0 Linac/MeV Contrast STX D STX D s.c...0. STX D., STX D STX D STX D STX D
9 Exposure Diagrams Exposure diagrams can be very useful for setting the correct exposure. The diagrams shown here are meant only as a guide, as the correct exposure will mainly depend on the variations of the object,the exposure equipment used and on the processing conditions. Structurix D Structurix D Steel (Fe) Structurix D Structurix D Type of X-ray tube: constant potential Pb-screens Density: FFD: m Autom. proc.: min. cycle, G, C Structurix D Structurix D
10 Structurix D Structurix D Aluminum (AI) Type of X-ray tube: constant potential Density: FFD: m Autom. proc.: min. cycle, G, C Structurix D Structurix D Structurix D Structurix D
11 Exposure Diagrams GBq.h Ci.h 0 00 Selenium Pb Screens: Density, SFD m 0 D D D D D D Fe GBq.h Ci.h 0 00 Iridium Pb Screens: Density, SFD m 0 D D D D D D Fe GBq.h Ci.h 0 00 Cobalt 0 Pb Screens: Density, SFD m 0 D D D D D D Fe
12
13 Special Applications STRUCTURIX F As a result of further improvements in its core business of radiographic film for all applications, Agfa introduced a better product for rapid access radiography. STRUCTURIX F is specially designed for offshore pipelines or similar applications. Such areas need short exposure time through the use of fluorometalic screens and fast processing cycles. This F film type is mainly blue sensitive. All UV and blue-emitting screens can be used, but for industrial use, fluorometallic screens (cfr. STRUCTURIX RCF) based on CaWO provide good quality. Manual processing can be used but without the advantage of consistent rapid processing. This should only be used as an emergency solution. Sensitometric curves with RCF fluorometallic screens (00 ) Density F + RCF* D with Pb Screen Relative Log (dose) STRUCTURIX F Relative Exposure Image Quality Film System 00 Ir STX F + RCF Screens, 0 sec., Dry to Dry, G, C STX D Pb Screens*, min., Dry to Dry, G, C *D is considered not sensitive for fluorescent screens (no significant gain in exposure time) Wire IQI (En -) Double Wire IQI (EN -) STRUCTURIX F Medium speed, high contrast fine grain film, preferably suited for use in combination with fluorometallic (RCF) or similar fluorescent screens. To be preferably processed in short cycle (0 sec.). If needed standard min. cycle can be used alternatively for: Offshore pipelines Fast processing requirements
14 Special Applications STRUCTURIX F Designed as a high quality film for fluorometallic (RCF) screen exposure when the speed obtainable with Pb screen system is insufficient or radiation safety is of prime importance. Sensitive to all UV and blue-emitting screens. Calcium tungstate with lead or lead oxide backing, so called fluorometallic screens (STRUCTURIX RCF Screens), are most suited for industrial applications. When maximum speed is important the use of very fast screens such as the STRUCTURIX 00 screen can further reduce the exposure time by a factor of three to six compared to RCF screens. F is the ideal fast, high contrast, high definition film for fluorescent screen applications. When higher sharpness is required we advise the use of D with Pb screens. Sensitometric curves with RCF fluorometallic screens ( 00 ) Density F + RCF D + Pb Log. rel. exp F with fluorescent screens is used in a variety of heavy construction applications, concrete, on stream examination of processing piping where X-ray energy has to be limited, flash radiography and microfocus enlargement techniques. Blue base Relative exposure factor with fluorometallic screens depends on: temperature radiation energy exposure time STRUCTURIX F High speed, high contrast fine grain film, for exposures in combination with RCF fluorometallic screens or fluorescent screens. High system speed is main requirement On stream corrosion/erosion radiography Concrete and heavy constructions Low dosage output, e.g. microfocus
15
16 STRUCTURIX Intensifying Screens The STRUCTURIX range offers two intensifying screens: the RCF fluorometallic screen and the high speed 00 fluorescent screen. Advantages The STRUCTURIX RCF fluorometallic and fluorescent 00 screens, based on the conventional phosphor material calcium tungsten (CaWO), diminish radiation exposure and/or the necessary level of radiation energy. They enable the radiographic penetration of thick objects. A more productive and effective testing method, the STRUCTURIX RCF and 00 screens reduce the exposure equipment load. The flexible screens enable radiography of curved objects. Features When excited by X-rays or gaa-rays, the STRUCTURIX RCF fluorometallic screen becomes blue emitting. The screen has an incorporated filter of lead oxide for scattered radiation. The emission spectrum is matched to the spectral sensitivity of the STRUCTURIX F type films. The strong fluorescent RCF screen offers the ideal compromise between detail perceptibility and working efficiency. The extra strong Electron-Beam-Cured (EBC) protective coating and the polyester support make the screen particularly durable. One of the most important applications of the STRUCTURIX RCF screens lies in the inspection of offshore pipelines. Combining the screen sensitivity and rapid processing of the STRUCTURIX F film provides an ideal film-screen system. In the on-stream as well, the use of the RCF-screen, in combination with the F film, leads to considerable time savings. The blue emitting STRUCTURIX 00 fluorescent screen has an extremely high absorption and conversion efficiency, together with acceptable detail perceptibility. Combined with a STRUCTURIX F or even a F film, this film-screen system becomes convenient for high-energy applications, such as the non-destructive testing of heavy construction and the examination of large concrete structures (bridges and buildings). The STRUCTURIX 00 screen can also be a solution for flash radiography in which exposure times are extremely short and for microfocus-enlargement techniques in which radiation doses are very low. Treatment of STRUCTURIX intensifying screens The STRUCTURIX screens should be protected from moisture, heat and ultra-violet radiation. Dust and marks should be removed from the screen iediately, using an approved screen cleaner. In addition to cleaning the screen, the Agfa Screen Cleaner contains an anti-static element, which prevents dirt and dust caused by static electricity from adhering to the screen.
17 STRUCTURIX Intensifying Screens Relative exposure factor Spectogram When making exposures with fluorescent screens, it is important to understand the potential impact of variables such as temperature, exposure energy and exposure time: Intensifying screens fluoresce more brilliantly at low temperature. Therefore, the screen efficiency will drop with increasing temperature With increasing energy, the absorption of fluorescent screens is reduced and, as a result, the intensifying effect is diminished Due to the reciprocity effect with fluorescent screen systems, the gain in exposure time compared to lead screen systems, diminishes with increasing exposure length S = ( uj cm ) Spectral sensitivity of Agfa Structurix F (for density.0 above fog) Relative emission spectrum of intensifying screens Relative Exposure F F D NDT RCF No screen NDT 00 + Pb RCF Pb.000 Ir NDT 00 + Pb RCF Pb.000 Co 0 NDT 00 + Pb RCF Pb.000
18 The Right Packaging for Every STRUCTURIX Film GE offers different forms of packaging. Whatever the application of industrial radiography, there is a right STRUCTURIX film available, in the right packaging. No object is too large or too small. An X-ray film of the appropriate size is available for every exposure. STRUCTURIX films are supplied in all standard sheet and roll sizes (special sizes on demand) and in darkroom or daylight packaging. SHEET FILM IN DAYLIGHT PACKAGING Pb VACUPAC PRACTICAL DAYLIGHT PACKAGING Time saving STRUCTURIX film are packed on ultramodern packaging machines. This ready-to-use packaging can be placed directly on the object to be X-rayed, which saves valuable time that would otherwise be used to manually place the film in cassettes in the darkroom. Improved quality To guarantee optimal packaging quality, all films are packed automatically in an ISO environment, using new lead screens for each. By excluding all so-called film faults, such as dust in the packaging and faults caused by the lead, the need for reshoots is eliminated, saving you time and money. More economical Ease of use, both during exposure and in the darkroom, and the avoidance of reshoots combine to provide maximum productivity. Completely light-tight, airtight and moisture proof Pb VACUPAC is the perfect daylight packaging. The STRUCTURIX X-ray films with Pb screens have a standard thickness of 0.0 and are vacuum-packed in a completely light tight, airtight and moisture proof foil complex. The foil, a spin off from space technology, is a metallic polymer involving the deposition of vaporized aluminum under vacuum. The synthetic foil ensures that VACUPAC can be used under extremely dirty and damp conditions. Pb VACUPAC is ideal for applications with energies higher than. Optimal image quality The vacuum between the STRUCTURIX film and the lead screens guarantees optimal image definition. Film/screen contact is retained fully, even when VACUPAC is placed around a spherical or curved work piece. Easy to use Either side of the wrapper can be placed on the object to be tested. A center cross on the envelope allows easy positioning. In addition, VACUPAC can be opened in one simple movement, thanks to the easy peel-off feature. Easy identification The film type is clearly marked on all daylight film packages. Pb means the film is sandwiched between lead screens (0.0 ). Daylight packed sheets have a center cross on the envelope to allow for easy positioning. Sheets are provided in a strong and easy-to-use, flip-top box. Rolls come in a rigid dispenser box. Extra vacuum protection. Each pack of sheets is supplied in vacuo to preserve the vacuum well beyond the expiration date.
19 The Right Packaging for Every STRUCTURIX Film Pb ETE (Edge-To-Edge) Edge-to-edge Pb versions are available for sheet sizes for that lack a VACUPAC version. A specific advantage of the edge-to-edge is its double-sided edge. This feature makes it possible to place the film against or between elements of a work piece easily and accurately. Opening the edge-to-edge packaging is as simple as tearing open the wrapper using the thread included for this purpose, then removing the film via the long side. The Pb edge-to-edge version is designed for exposures with energies higher than and isotopes. DW ETE (Edge-To-Edge) This light-tight, moisture proof and greaseproof packaging without Pb screen is ideal for exposures using radiation energy lower than. The envelopes can be cut easily and taped for use with odd-shaped angles and corners. The envelopes are also easy to tape to the work piece. ROLLS IN DAYLIGHT PACKAGING Whether you X-ray pipelines, pressure vessels, airplanes or storage tanks, with roll film packaging you can determine the length of film yourself so that your radiographs can be made in one piece. Easy to use Cassettes are unnecessary with ROLLPAC packaging. The film is packed in accordance with the edge-to-edge system. ROLLPAC can be placed accurately on the object to be tested (i.e., a long weld) or right into the corner of a flange. ROLLPAC is placed around the object and attached with adhesive tape. Identification of the exposure needs to occur only once. This time saving ROLLPAC packaging is supplied in a practical dispenser box. Opens quickly and easily The special design of the ROLLPAC wrapper allows quick and easy opening. The film is removed by taking the non-printed wrapper, together with the lead screen and the film in one hand and the printed wrapper and the other lead screen in the other. In this way, the film can be stripped easily from the packaging. ROLLPAC in wider formats (>cm) has a tear strip on either side of the wrapper. This enables the film to be removed from the packaging easily and quickly. Length indication on the wrapper This feature allows you to easily determine where to cut the film and also to see how much film is left. The film can be cut to any length. Cutting should be done in the darkroom. Pb ROLLPAC Light-tight, moisture proof and greaseproof The film is sandwiched between two 0.0 lead screens. ROLLPAC packaging is completely light-tight. The packaging is resistant to moisture and grease. Optimal image quality Our unique packaging ROLLPAC ensures that excellent contact between the film and lead foil is retained when the media is applied to spherical or tubular objects, even those with a small diameter. Because the screens are only used once, optimal results are guaranteed.
20 For testing at higher radiation energy levels (> ), i.e., welding in boilers, storage tanks and pipelines, Pb ROLLPAC is used. DW ROLLPAC DW ROLLPAC packaging is specifically intended for material testing using low to very low radiation energy (< ). Widths up to cm are available. ROLLPAC PRECUT Highly economical Films in ROLLPAC packaging can be supplied in precut lengths from 0 cm by special order only. This exclusive form of packaging is ideal for pipeline projects, which generally consist of large series of pipes of the same diameter. We can supply ROLLPAC precut in the length required for your project, saving you a considerable amount of time and money. 0
21 The Right Packaging for Every STRUCTURIX Film SHEET FILM IN DARKROOM PACKAGING These films are for use with reloadable metal or plastic cassettes and exposure holders. The high level of darkroom lighting tolerated by STRUCTURIX D films allows more comfortable loading and unloading conditions. Because of its low cost, darkroom packaging appears to be the most economical solution for certain applications. However, the total radiography cost must be considered. For example, film handling costs in the darkroom and the cost of reshoots are important factors in figuring your investment. The added expense of cassettes and screens should also be taken into consideration. Local conditions must be considered and, most importantly, the cost of quality (the you get what you pay for theory). Simply put, low cost does not always equate to your best decision or best value. VACUPAC image quality cannot be obtained with the standard cassette system. NIF (Non Interleaved Films) This is the most economical way to buy sheet film. The intrinsic film quality is the same as that of pre-packed film. Sheets of film are packed per (except extremely large sizes) in a paalpo bag inside a cardboard box. The paalpo bags allow for easy film removal and re-closure. FW (Folder Wrapped) Each film is wrapped in a paper folder to prevent handling faults in the darkroom. The paper folders make it easy to store and protect the films after processing. Folder wrapped packaging is an ideal solution for boxes that, after opening, remain in use for a period of time in areas of high humidity and temperature, as the folder prevents the films from sticking together. Sheets of film are packed per in a sealed bag and placed in a strong cardboard box.
22 Optimal Storage Of STRUCTURIX Films Handling and storage of X-ray film is an important aspect of the radiographical process. Guidelines are given in several international standards, i.e., ASTM E-. Following are the recoendations for unexposed X-ray film. ROLLS IN DARKROOM PACKAGING BLR (Bulk Load Roll) BLR is packaging with bare film on a cardboard core. This film can be cut to any length and loaded with or without lead screens in reloadable cassettes in the darkroom. Available in a standard width of 0 and in lengths of. m (0 ft.) and 0 m (,000 ft.). TAILOR MADE PACKAGING In addition to our standard products, special orders are available. These can include non-standard sheet sizes and other forms of packaging, such as Bi and Tri Packs. For special orders, please contact your Agfa agent. Bipack is an ETE daylight packaging containing two films. Tripack contains three films in one envelope. Combinations with lead screens are possible. Bipacks can also be supplied in DW ROLLPAC packaging. First, storage facilities for unexposed X-ray films should provide adequate protection from any penetrating radiation. If the films are stored for longer than three months, background radiation may not exceed 0 ngy/h ( x - C/Kg/h). Films in containers sealed by the manufacturer should be stored with the films on edge, whenever possible. Storage temperature should be between. C and. C at a relative humidity range of 0 to 0 percent. As higher temperatures accelerate certain physicochemical processes in the emulsion, STRUCTURIX films should always be stored in a cool place (within the above mentioned temperature range). While films in opened packages are also affected by humidity, it is advisable to ensure that the relative humidity in the storage room remains under 0 percent. It is also recoended that the films are not stored in the iediate vicinity of X-ray chemicals. If STRUCTURIX films are handled and stored in accordance with the directions noted above, we guarante their good quality at least until the expiration date on the box.
23 GEIT-000EN (0/) 0 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.
Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes
Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes Radiographic Image Production X-ray photons emitted from the x-ray tube interact with the body, exit the patient (exit beam) and interact
X-ray 100KV. Speed as compared to that of type IX100 used as a standard 100 under each exposure conditions.
DATA SHEET INDUSTRIAL RADIOGRAPHIC SYSTEMS RADIOGRAPHIC FILM IX20, IX25, IX50, IX80, IX, IX, IX29 AND IX59 Fujifilm industrial X-ray films feature revolutionary new film technology. The combination of
INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer
INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer X-rays were discovered by W.C. Roentgen because of their ability to cause fluorescence. X-ray photons cannot be seen. The image produced
Standard Test Method for Classification of Film Systems for Industrial Radiography 1
Designation: E 1815 96 (Reapproved 2001) Standard Test Method for Classification of Film Systems for Industrial Radiography 1 This standard is issued under the fixed designation E 1815; the number immediately
Cutting Edge Digital Radiography Technology in Daily NDT Use
Cutting Edge Digital Radiography Technology in Daily NDT Use Ron PINCU, Eli DAYAN, Ofra KLEINBERGER Vidisco Ltd. Or-Yehuda, Israel 60375 Tel: +972 (3) 533-3001 Email: [email protected] ABSTRACT Digital Radiography
Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project
IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project U. Ewert, U.
KODAK PLUS-X AEROGRAPHIC Film 2402
AS-45 KODAK PLUS-X AEROGRAPHIC Film 2402 KODAK PLUS-X AEROGRAPHIC Film 2402 is a panchromatic, negative camera film with medium speed, medium-high contrast, and extended red sensitivity for the reduction
KODAK INDUSTREX Products
KODAK INDUSTREX Products Contact your local Kodak Area Manager or visit our site on the Internet at www.kodak.com/go/ndtproducts for more information about this and other KODAK INDUSTREX Products. Eastman
Tractor Painting Tips
Keeping your tractor or equipment well kept & free from rust & corrosion will extend the life of your investment & help retain its value for a longer period of time. It can be difficult, in many cases,
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
KODAK PANATOMIC-X AEROGRAPHIC II Film 2412 KODAK PANATOMIC-X AERECON II Film 3412
AS-112 KODAK PANATOMIC-X AERECON II Film 3412 and KODAK PANATOMIC-X AERECON II Film 3412 are panchromatic, black-and-white aerial camera films with extended red sensitivity and intermediate speed. Both
Dimensional Change Characteristics for Printed Circuit Board Films
TECHNICAL DATA / PRINTED CIRCUIT BOARD FILM Dimensional Change Characteristics for Printed Circuit Board Films High Complexity PCB Starts With the Right Phototools October 2010 TI-2530 INTRODUCTION Kodak
Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral
Dental Radiography X-rays for dental radiography are produced by high voltages of electricity within an x-ray head and come out through a metal tube called a collimator. This ensures the x-rays only come
ISO 400/27 BLACK AND WHITE PROFESSIONAL FILM FOR HIGH PRINT QUALITY AND FLEXIBILITY IN USE
TECHNICAL INFORMATION o ISO 400/27 BLACK AND WHITE PROFESSIONAL FILM FOR HIGH PRINT QUALITY AND FLEXIBILITY IN USE ILFORD HP5 Plus is a fast black and white film. It is ideal for action, available light
Agfa Materials Printed Circuit Boards. High Resolution Film. HRR & HRO Technical Information
ab Agfa Materials Printed Circuit Boards High Resolution Film HRR & HRO Technical Information April 27 HRR AND HRO Technical Information HRR is a red-sensitive line film. It is especially designed for
NON-DESTRUCTIVE TESTING OF PIPELINES. L. Annila. Abstract
NON-DESTRUCTIVE TESTING OF PIPELINES L. Annila Abstract This paper shall present different, contemporarily available non-destructive testing (NDT) methods of pipelines and compare them to each other from
COATED CARBIDE. TiN. Al 2 O 3
COATED CARBIDE GENERAL INFORMATION CVD = Chemical Vapour Deposition coated grades GC2015, GC2025, GC2135, GC235, GC3005, GC3015, GC3020, GC3025, GC3115, GC4015, GC4025, GC4035, S05F, and CD1810. PVD =
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
Application of Welding Standards in Hong Kong. S. K. Babu Laboratory Manager - Foundation Techniques Ltd
Application of Welding Standards in Hong Kong S. K. Babu Laboratory Manager - Foundation Techniques Ltd Introduction: This paper summarizes the current welding standards practiced in Hong Kong & also outlines
COATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
Digital radiography conquers the veterinary world
Digital radiography conquers the veterinary world Author: Dirk De Langhe Increasingly, veterinarians are using medical imaging to diagnose their patients. There is a corresponding tendency towards replacing
proper way. Therefore operator training and certification is key in every inspection program to ensure compliance and improve quality and integrity.
SGS NDT Training & Examination Centre Professional Services for Your Safety and Reputation ABOUT NON DESTRUCTIVE TESTING (NDT) About NDT NDT plays a key role in assessing conformity and reliability of
Coating Thickness and Composition Analysis by Micro-EDXRF
Application Note: XRF Coating Thickness and Composition Analysis by Micro-EDXRF www.edax.com Coating Thickness and Composition Analysis by Micro-EDXRF Introduction: The use of coatings in the modern manufacturing
Peel & Seal Self-Stick Roofing Solutions
Peel & Seal Self-Stick Roofing Solutions Ideal for Low Slope Applications Waterproof and Weatherproof Energy Efficient Tough and Durable Versatile, Effective Sealing Around Protrusions Perfect for Vents,
BENTLEY ELEMENTS COLLECTION LVT
This document refers to the following products: Product Size Installation direction Seams treatment Elements Tiles See specifications 90 None Elements Planks See specifications Stair Step None Note: This
Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers
Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers Universal container K 470 the original since 1950 Often copied but never equalled or bettered
B&W PAPER DEVELOPERS DEVELOPERS FOR THE DISH/TRAY PROCESSING OF BLACK AND WHITE PHOTOGRAPHIC PAPERS
TECHNICAL INFORMATION B&W PAPER DEVELOPERS DEVELOPERS FOR THE DISH/TRAY PROCESSING OF BLACK AND WHITE PHOTOGRAPHIC PAPERS ILFORD MULTIGRADE developer MULTIGRADE is a rapid liquid concentrate dimezone-s/hydroquinone
FLEXIBLE CIRCUITS MANUFACTURING
IPC-DVD-37 FLEXIBLE CIRCUITS MANUFACTURING Below is a copy of the narration for DVD-37. The contents of this script were developed by a review group of industry experts and were based on the best available
INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles
INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier
FUJICOLOR CRYSTAL ARCHIVE DIGITAL PAPER TYPE DPII
AF3-212E COLOR NEGATIVE PAPERS FUJICOLOR CRYSTAL ARCHIVE DIGITAL PAPER TYPE DPII 1. FEATURES AND USES FUJICOLOR CRYSTAL ARCHIVE DIGTAL PAPER TYPE DPII is a silver halide color paper designed exclusively
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
High-strength and ultrahigh-strength. Cut sheet from hot-rolled steel strip and heavy plate. voestalpine Steel Division www.voestalpine.
High-strength and ultrahigh-strength TM steels Cut sheet from hot-rolled steel strip and heavy plate Josef Elmer, Key account manager voestalpine Steel Division www.voestalpine.com/steel Weight savings
Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
TECHNICAL INFORMATION DELTA 400 PROFESSIONAL ISO 400/27º, FINE GRAIN, BLACK AND WHITE PROFESSIONAL FILM FOR SUPERB PRINT QUALITY
TECHNICAL INFORMATION DELTA 400 PROFESSIONAL ISO 400/27º, FINE GRAIN, BLACK AND WHITE PROFESSIONAL FILM FOR SUPERB PRINT QUALITY ILFORD DELTA 400 PROFESSIONAL is a fast, fine grain, black and white professional
peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11
CONTENT peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11 PEEL ADHESION Testing the peel adhesion on stainless steel 1. Definition Peel adhesion - The
Technical Data Sheet February 2014
Scotch-Weld Technical Data Sheet February 2014 Product Description s are high performance, two-part acrylic adhesives that offer excellent shear, peel, and impact performance. These toughened products
DELTA PROFESSIONAL TECHNICAL INFORMATION EI 3200/36, HIGH SPEED, BLACK AND WHITE PROFESSIONAL FILM FOR SUPERB PRINT QUALITY
TECHNICAL INFORMATION DELTA PROFESSIONAL EI 3200/36, HIGH SPEED, BLACK AND WHITE PROFESSIONAL FILM FOR SUPERB PRINT QUALITY LFORD DELTA 3200 PROFESSIONAL is a high speed, black and white professional film
SCREEN PRINTING INSTRUCTIONS
SCREEN PRINTING INSTRUCTIONS For Photo-Imageable Solder Masks and Idents Type 5600 Two Part Solder Masks and Idents Mega Electronics Ltd., Mega House, Grip Industrial Estate, Linton, Cambridge, ENGLAND
Premium Tubular Solutions Super Duplex Welded Tubes for Umbilical Applications
Premium Tubular Solutions Super Duplex Welded Tubes for Umbilical Applications Premium Tubular Solutions Innovative Tubes for Umbilical Applications Over 35 years of experience in Premium welded t ubular
Fundamentals of Extrusion
CHAPTER1 Fundamentals of Extrusion The first chapter of this book discusses the fundamentals of extrusion technology, including extrusion principles, processes, mechanics, and variables and their effects
Designed for comfort and built to last.
Designed for comfort and built to last. Inter IKEA Systems B.V. 2015 Whether we work in an office or at home, many of us spend the majority of the day at a desk. A comfortable workspace is therefore essential
Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.
Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc. Abstract The technology for connecting lead and magnet wires for electric motors and electro mechanical devices
Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION
Sikadur-Combiflex REVISED JULY 2002 Sealing system for cracks and problem joints with large movements Construction DESCRIPTION USES ADVANTAGES The Sikadur-Combiflex joint sealing system consists of two
Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth
Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth Bulk deformation forming (rolling) Rolling is the process of reducing
Chapter 2 Basis of design and materials
Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural
FUJICOLOR PRO 800Z PROFESSIONAL
AF3-177E COLOR NEGATIVE FILMS FUJICOLOR PRO 800Z PROFESSIONAL 1. FEATURES AND USES FUJICOLOR PRO 800Z PROFESSIONAL is an ISO 800 high-speed color negative film that is especially suitable for portrait,
Eddy-current testing - Non-destructive testing for flaw detection of metals, coatings and carbon fibres
Technology Offer Eddy-current testing - Non-destructive testing for flaw detection of metals, coatings and carbon fibres Summary A German SME offers the development of task specific eddy-current based
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
RTV162. Electronic Grade Silicone Adhesive Sealant
RTV162 Product Description Electronic Grade Silicone Adhesive Sealant RTV162 adhesive sealant from GE Silicones is one-component, readyto-use electronic grade silicone sealant. It cures to a tough, resilient
Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.
Double Glazing Glass Energy Saving Solutions Harris Silicones & Glass (Pvt.) Company Introduction Pioneers of Silicone Sealants in Pakistan Manufacturing in collaboration with Momentive Performance Materials
3 Single-Coated Foam Tapes
3 Single-Coated Foam Tapes Technical Data May, 2008 Product Description 3M Single-Coated Foam Tapes will adhere to a variety of substrates, including latex-painted wood, lacquered wood, enameled steel,
OR Technology. Non Destructive Testing (RT) Strong Workmate for
OR Technology Strong Workmate for Non Destructive Testing (RT) Who We Are What We Do OR Technology Digital X-ray and Imaging Solutions producing digital X-ray technology and developing image management
Aluminium foil properties: Applications of aluminium foils and thin gauge strips in thickness below 0,50 mm:
1 ALUMINIUM FOILS AND THIN GAUGE STRIPS The year 2010 has been celebrated as the 100th anniversary of aluminium foil. Ever since the beginning in 1910 the usage of foil has been growing and products developed
Basic Properties and Application of Auto Enamels
Basic Properties and Application of Auto Enamels Composition of Ceramic Automotive Glass Enamels Ceramic automotive glass colours are glass enamels that fire on to the glass during the bending process
DIRECT PRINTING NYLON JACKETS. The Basics
DIRECT PRINTING NYLON JACKETS The Basics . The Nylon Jacket Types of Nylon There are three basic weaves that are commonly used to manufacture nylon jackets or outerwear. These are Taffeta, Satin and Oxford.
Phosphoric Acid Anodized Aluminum Honeycomb
Phosphoric Acid Anodized Aluminum Honeycomb Description 02 and 06 expanded aerospace grade aluminum honeycomb materials are available in a wide selection of cell sizes and foil gauges. The HexWeb CR-PAA
PAAM COMMERCIAL PRIVATE LIMITED
METAL PACKAGING We at Paam Group have been providing vast range of packaging products to our customers based on their preferences, needs and specifications. We provide all the materials required in metal
Trace Gas Exchange Measurements with Standard Infrared Analyzers
Practical Environmental Measurement Methods Trace Gas Exchange Measurements with Standard Infrared Analyzers Last change of document: February 23, 2007 Supervisor: Charles Robert Room no: S 4381 ph: 4352
Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9
Module 9 This module presents information on what X-rays are and how they are produced. Introduction Module 9, Page 2 X-rays are a type of electromagnetic radiation. Other types of electromagnetic radiation
SUPPLIER QUALITY ASSURANCE REQUIREMENTS
SUPPLIER QUALITY ASSURANCE REQUIREMENTS The following supplier quality assurance requirements, referenced by number on the Purchase Order, are an integral part of each order placed by Continental Disc
HexWeb CR III Corrosion Resistant Specification Grade Aluminum Honeycomb
Corrosion Resistant Specification Grade Aluminum Honeycomb Description 5052 and 5056 expanded aerospace grade aluminum honeycomb materials are available in a wide selection of cell sizes and foil gauges.
Non-destructive testing of steel forgings - Part 2: Penetrant testing (BS EN 10228-2:1998)
Non-destructive testing of steel forgings - Part 2: Penetrant testing (BS EN 10228-2:1998) 1 Scope This part of EN 10228 describes the method and acceptance criteria to be used for the penetrant testing
Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes
Naue GmbH&Co.KG Quality Control and Quality Assurance Manual For Geomembranes July 2004 V.O TABLE OF CONTENTS 1. Introduction 2. Quality Assurance and Control 2.1 General 2.2 Quality management acc. to
Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.
Self-Cleaning The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Conservatories bringing the outside in. Pilkington Activ has made
STABILITY TESTING: PHOTOSTABILITY TESTING OF NEW DRUG SUBSTANCES AND PRODUCTS
INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE STABILITY TESTING: PHOTOSTABILITY TESTING OF NEW
FUJI INSTANT COLOR FILM New FP-100C / FP-100C SILK
AF3-129E INSTANT PHOTO SYSTEMS FUJI INSTANT COLOR FILM New FP-100C / FP-100C SILK 1. FEATURES AND USES The New FUJI INSTANT COLOR FILM FP-100C/FP- 100C SILK is a peel-apart-type instant color film with
Applications and Benefits of Multi-Walled Carbon Nanotubes (MWCNT)
I Applications and Benefits of Multi-Walled Carbon Nanotubes (MWCNT) Table of Content 1 Introduction...1 2 Improved Properties...1 3 Potential Applications...1 3.1 Current / short-term applications...3
MAKING A BETTER MARK WITH INK JET As substrates, industry regulations and customer demands change, fluids are also evolving
MAKING A BETTER MARK WITH INK JET As substrates, industry regulations and customer demands change, fluids are also evolving By Dan Laird, technical support chemist, Videojet Technologies Inc. On the surface,
Non-Destructive Testing
Non-Destructive Testing Bureau Veritas is one of the largest Testing, Inspection and Certification service providers in the world. First established in 1828, Bureau Veritas now spans the globe with a network
Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis
Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis David Bernard & Steve Ainsworth Dage Precision Industries Abstract Non-destructive testing during the manufacture of
Reach Higher with Inspection Academy GE s Inspection Technologies Global Knowledge Center. www.geinspectionacademy.com
Reach Higher with Inspection Academy GE s Inspection Technologies Global Knowledge Center www.geinspectionacademy.com Sharing knowledge. Shaping technology. At GE, we know the value of investing in your
SikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
The ColorMatrix quick guide to liquid color. for plastics and silicones
The ColorMatrix quick guide to liquid color for plastics and silicones 1 Colorant selection Understanding which colorant technology best suits your particular product application will help ensure you gain
Non- Carbon Fiber Electrical Heating Textile Introduction:
Non- Carbon Fiber Electrical Heating Introduction: This Heating is a new generation electrical heating system which is specially designed for mobile heating, energy saving and safety orientated requirements
Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013
Scotch-Weld TM Product Data Sheet Acrylic Adhesives Date: Supersedes: August 2013 Product Description 3M TM Scotch-Weld Acrylic Adhesives are high performance, twopart acrylic adhesives that offer good
Vacuum Evaporation Recap
Sputtering Vacuum Evaporation Recap Use high temperatures at high vacuum to evaporate (eject) atoms or molecules off a material surface. Use ballistic flow to transport them to a substrate and deposit.
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves
Pilkington Activ self-cleaning glass. The clear choice for your conservatory.
Pilkington Activ self-cleaning glass. The clear choice for your conservatory. The Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories bringing
Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory
FIELD APPLICATION REPORT UV/Vis/NIR Spectroscopy Author: Frank Padera Shelton, CT Contributor: Chris Lynch Shelton, CT Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR
Bafl-Sorb Sound Absorbing Ceiling Baffles
Bafl-Sorb Sound Absorbing Ceiling Baffles INC offers a complete line of Sound Absorbing Ceiling Baffles to compliment any environment. Our ceiling baffles are among the most cost-effective method of adding
Types Name Description. Films Polyethylene 4 and 6 mil Regular UV. Rigid Plastics Fiberglass" Fiber reinforced. "Plexiglass" or equal
Greenhouse Coverings One of the most important parts of a greenhouse facility is the covering. Since sunlight is generally the limiting factor in wintertime greenhouse production, a covering that transmits
DELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
Double Coated Urethane Foam Tapes
3 Double Coated Urethane Foam Tapes 4004 4008 4016 4026 4032 4052 4056 4085 Technical Data April, 2009 Product Description 3M Double Coated Urethane Foam Tapes are conformable foams that offer high shear
T5 LongLast. GE Lighting DATA SHEET
GE Lighting T5 LongLast DATA SHEET Linear Fluorescent Lamps T5 LongLast High Efficiency 14W, 21W, 28W, 35W T5 LongLast High Output 24W, 39W, 49W, 54W, 8W Product information T5 LongLast lamps are triphosphor
POLYURETHANE FOAM CONCEPT
POLYURETHANE FOAM CONCEPT Scandinavian Product Range (Now with Nordic Product Labels) In General Selena FM has become the second largest polyurethane manufacturer in the world in under 30 years of operations
Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids
Principles of Imaging Science II (RAD 120) Radiographic Grids 1 Image-Forming X-Rays Four X-ray paths a. X-rays interact with patient and scatter away from the receptor b. X-rays interact and are absorbed
Roofing. Sarnafil S 327-15EL. Polymeric membrane for roof waterproofing. Product Description
Roofing Product Data Sheet Edition 02.2015 Identification no: 02 09 01 01 201 0 150000 Version no. 04 Sarnafil S 327-15EL Polymeric membrane for roof waterproofing Product Description Sarnafil S 327-15EL
FUJICHROME 64T TYPE II Professional [RTPII]
AF3-024E COLOR REVERSAL FILMS FUJICHROME 64T TYPE II Professional [RTPII] 1. FEATURES AND USES FUJICHROME 64T TYPE II Professional [RTP II] is an ISO 64 speed tungsten-type high image quality color reversal
An Overview of Digital Imaging Systems for Radiography and Fluoroscopy
An Overview of Digital Imaging Systems for Radiography and Fluoroscopy Michael Yester, Ph.D. University of Alabama at Birmingham Outline Introduction Imaging Considerations Receptor Properties General
Cutting Tool Materials
Training Objectives After watching the video and reviewing this printed material, the viewer will gain knowledge and understanding of cutting tool metallurgy and specific tool applications for various
Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)
Approved 402;2521 1 2521 zinc epoxy ^(ValidationDate). 1 Product description This is a two component polyamide cured zinc rich epoxy coating. It is a very high zinc dust containing product. It conforms
ISO 125/22º BLACK AND WHITE PROFESSIONAL FILM FOR HIGH PRINT QUALITY AND FLEXIBILITY IN USE
FACT SHEET April 2004 ISO 125/22º BLACK AND WHITE PROFESSIONAL FILM FOR HIGH PRINT QUALITY AND FLEXIBILITY IN USE ILFORD FP4 Plus is an exceptionally fine grain, medium speed, black and white film. It
Specification MBT801-S
Specification MBT801S Drawn SSC Approval 고객명 Approval.com MBT801S 1. Features 2. Absolute Maximum Ratings 3. Electro Characteristics 4. Optical characteristics 5. Outline Dimension 6. Packing 7. Soldering
Engine Bearing Materials
Engine Bearing Materials Dr. Dmitri Kopeliovich (Research & Development Manager) The durable operation of an engine bearing is achieved if its materials combine high strength (load capacity, wear resistance,
GEOMETRY OF SINGLE POINT TURNING TOOLS
GEOMETRY OF SINGLE POINT TURNING TOOLS LEARNING OBJECTIVES Introduction to Features of single point cutting tool. Concept of rake and clearance angle and its importance System of description of Tool geometry
QUALITY ASSURANCE IN DENTAL RADIOGRAPHY. Part of the Ionising Radiation Regulations Section 4 (3) IR(ME)R 2000
QUALITY ASSURANCE IN DENTAL RADIOGRAPHY Part of the Ionising Radiation Regulations Section 4 (3) IR(ME)R 2000 Quality Assurance (QA) Ensure consistently adequate diagnostic information whilst keeping doses
Handbook on the Ultrasonic Examination. Austenitic Welds
Handbook on the Ultrasonic Examination Austenitic Welds The International Institute of Welding Edition Handbook On the Ultrasonic Examination of Austenitic Welds Compiled by COMMISSION V Testing, Measurement,
NON DESTRUCTIVE TESTING & ASNT WELD INSPECTION & AWS
NON DESTRUCTIVE TESTING & ASNT WELD INSPECTION & AWS What is ASNT? What is ASNT? The American Society for Nondestructive Testing, Inc. What is ASNT? ASNT is the world's largest technical society for nondestructive
Welding of Plastics. Amit Mukund Joshi. (B.E Mechanical, A.M.I.Prod.E)
Welding of Plastics Amit Mukund Joshi (B.E Mechanical, A.M.I.Prod.E) Introduction Mechanical fasteners, adhesives, and welding processes can all be employed to form joints between engineering plastics.