Owner s Manual for Dentalaire Prestige Dental Stations
|
|
|
- Donald Bell
- 9 years ago
- Views:
Transcription
1 Owner s Manual for Dentalaire Prestige Dental Stations Toll Free (800) Fax (714) Newhope Street, Suite 407, Fountain Valley, CA 92708
2
3 NOTES Limited Warranty DENTALAIRE warrants it products to be free from defects in materials and workmanship only. No other warranties are expressed or implied. Air Compressors & Portable Dental Units All compressors and portable dental units including wall mount dental units are warranted for one (1) year. High speed turbines are warranted for six (6) months. The High Speed Handpiece is warranted for one (1) year. Slow Speed Handpiece and Ultrasonic Scalers are warranted for two (2) years. The Sonic Air Scaler Handpiece is warranted for one (1) year. Warranty is limited to repair, parts or replacement of item by Dentalaire. WARRANTY IS VOID IF ITEMS ARE CARELESSLY USED OR IMPROPERLY MAINTAINED OR IMPROPERLY INSTALLED. NO CLAIM FOR LABOR OR CONSEQUENTIAL DAMAGES WILL BE ALLOWED. In s t r u m e n t s All DENTALAIRE and Vetcare Dental Instruments are warranted for one (1) year. If any of our instruments break, chip, or bend during any dental procedure, Dentalaire will replace the instrument at no charge. Defective item must be returned to us for exchange. Te r m s Net 30 days on approved accounts. A service charge of 1-1/2% per month (order only) will be charged on past due accounts. All prices subject to change without notice. All prices are FOB Fountain Valley, California or Houston, Texas. 15% handling charge on all returned items, unless deemed defective. Returned items must be shipped prepaid. Items may not be returned without factory authorization. International orders must be accompanied by an irrevocable Letter of Credit. All shipping to be paid by customer. When placing your order please include product number, description and quantity. Also your purchase order number, shipping date required and method of shipping.
4 SET UP PROCEDURE FOR DENTALAIRE DENTAL STATIONS Step 1: Open crate using a large screwdriver. Please check crate for any damages and report them to Dentalaire at (800) immediately or note on paperwork while receiving a damaged unit. Step 2: Loosen the bolts at cross-member with a 7/16 wrench or socket as it should be carefully rolled and gently lifted out of the crate. Step 3: Carefully remove all the packing material that goes around the tubing for the high and low speed handpieces. Also the tubing that goes to the piezo scaler tubing. Please remove all other packing material. Step 4: First remove the three large zip ties off of the compressor. On the side of the compressor opposite the purge valve, connect the Air Intake Filter. This is the black mushroom shaped cap, that screws on where the red cap is. The hole that you can see and feel on the Air Intake Filter should be at 12:00, not 6:00. It you have it at 6:00 oil can leak out. This should be cleaned yearly with soapy water or alcohol, rinsed well and put back on. The Air Intake Filter keeps the compressor running quietly and also keeps foreign debris out of the motor. Step 5: Open the 22 oz. bottle of synthetic compressor oil. At the top of the compressor is the oil fill hole. This is where you are to put the oil. Unscrew and start adding the oil. Go slowly and empty the bottle by about half to two thirds empty. Wait a few minutes as the oil takes some time to go into the compressor. Slowly add some more oil and wait until you see the oil in the glass eye on the side of the compressor and stop when it gets to the mid level (the red line). In most cases you will usually use about 7/8 th of the bottle. Add oil until level in sight glass is half full while motor is not running. The oil level must be half full on the sight glass. On any mobile dental station it is easier to fill the compressor with oil, when the table is at its highest 36 level, not when it is right above the compressor. Please change the oil yearly. Make sure to raise the table before putting in the compressor oil. Step 6: Take the 2 water bottles off of the machine and fill with distilled water leaving about two inches of air space at the top. Step 7: Connect the power cord to 110 V ac grounded receptacle and place compressor power switch in the ON position, which means the switch on top of compressor is turned clockwise. On units that have a scaler or a fiber-optic system, you will also need to hit the switch underneath the table part of the mobile dental station. Step 8: Unpack both handpieces and find the Once A Day Spray Handpiece Lubricant. Lubricate highspeed drill only, the slowspeed polisher is lube free. Insert the spray tip of the Once A Day Spray into the drive port at the base of the handpiece, spray once and then remove. Do this for highspeed drill only. Step 9: Attach the handpieces to the appropriately labeled tubing located on the tubing connectors. Step 10 - Depress the foot control for 5 10 seconds to permit air to purge excess lubricant from the highspeed handpiece. Do not lubricate any other handpiece. The slowspeed is a lube free handpiece. NOTES 2
5 NOTES Lubricating Handpiece Attaching Handpiece CAUTION: Do not operate any handpiece without a bur, prophy angle, contra angle or bur blank tightened securely in place. Permanent Turbine/Chuck damage will result! Step 11: Next open up the bag containing the parts to your piezo electric ultrasonic scaler. There are two blue rubber sleeves, to install simply slip over the handpiece. You have two dental inserts which come with your scaler. One is # 32, which is your flat or wide tip. This is for heavy duty scaling. The other is # 39, which is your fine or universal tip. Typically used for your fine or delicate scaling. Many clinics will use this subgingivally. These tips are screwed into place using one of the two wrenches which come with this unit. Now you gently screw the dental tip into place. Finger tight is all that s required. Dentalaire also carries a true Perio Tip for subgingival scaling. It is a little longer and thinner than the Universal Tip (# 39). DTP00786 is the order number for the Special/Perio Tip (# 33). Dental Inserts Step 12: Please make sure the water switch is on and the water flow control knob is open. Counterclockwise is open (to the left), clockwise is all the way shut (turning all the way to the right). The little button on the foot control activates the piezo electric scaler only. The power setting is usually set at around If you do an enormous amount of dentals, e.g a day, 5 days a week, you could wear these tips out in 3 4 months. 3
6 CAUTION: Never, ever use worn out tips. This will result in severe damage to the handpiece and could cost you a lot to get it repaired. Please routinely check the tips by using the chart provided, which shows expected tip wear. Remember, if you are having to constantly adjust the power setting up, the tips are probably worn and need to be replaced. To clean the tips, do the following: 1. Brush off and rinse the tip with water. Tee Master Unit On/Off Bottle Select HP Coolant Flow HP Select Scaler Water Flow Scaler Control Foot Control /8" Clear 1/4" Clear 1/8" Sterling 1/4" Sterling 1/8" Blue 1/4" Blue Handpiece Pressure Gauge It can be sterilized with a cold sterile solution or put in a ultrasonic cleaner. 3. Autoclave the tips at 275 F for no longer than 15 minutes. Enjoy your new dental unit. Please call us at (800) if you have any questions. We are here to help in any way we can. For High-speed, slowspeed polisher, blue metal airscaler, prophy angles and contra angles questions, ask for Debbie McCullah. Syringe To Syringe Handpiece Flow Adj. Block Shuttle Valve Scaler Control Board To Scaler For Technical Questions on dental machines, call Paul, Daniel and Wes. For all other questions, ask for Daniel Strange. Please note: If you have any kind of damage, please notify Dentalaire right away. We have a two week window where we can make a claim if there are any damages to the dental station. After that, if you get a dental station from us, have it for a month, open it up and then find damages, we cannot get any kind of credit from our shipper. This makes it very difficult for all parties involved. Thanks for your help in this matter. SELECTION OF HANDPIECES Your dental station comes with a high-speed and a Low-speed handpiece. The high-speed is for drilling and sectioning of the teeth. The low speed is used mainly for polishing. It also can have an air scaler or a piezo scaler, which is used to scale (clean) the teeth. OPERATION OF HANDPIECES High-Speed Handpiece operates at pressures of 38 to 40 PSI and attains a speed of 350,000 to 400,000 RPM. The water mist helps to keep the handpiece motor and bur cool, as well as the patient s tooth cool while doing restorations, cutting or rotary prophy scaling procedures. 2 Handpiece Automatic Control J-4300 Lo-Speed HP Illumination To Lo-Speed Handpiece To Hi-Speed Handpiece Non-Retraction Water Relay Valve Mini Regulator Constant preventive maintenance is essential in caring for handpieces. If they are not properly cleaned and lubricated, abrasives such as finely ground tooth, metal will cause excessive wear and undue vibration. When inserting and removing burs from handpieces, use the bur tool by holding it between the thumb and forefinger. Slide the bur tool over the head of the handpiece. Pull the wrench knob away from the head, then push the knob back to engage the chuck. The square tip of the wrench must fit into the square hole inside of the handpiece head (this is the chuck). To remove the bur, rotate the wrench one full turn Counter Clockwise until the bur is free. To tighten, rotate the wrench one full turn Clockwise until the bur is secure. Amdent Scaler Out to Foot Control Air In Illumination Control Board Never overtighten the bur, as serious damage can result to the chuck and bur tool. On units that have a push button bur changer, to insert the bur simply push your thumb on the back cap of the high speed handpiece to engage the chuck. You will feel a click, and then you insert the bur all the way as far as you can. To take out repeat the above step and then pull out the bur. 4 17
7 Push Button Bur Bur Tool Changing If you do not put the bur in all the way it will damage the chuck. You will then need to purchase a new turbine for your high speed handpiece. Slow-Speed Handpiece operates at pressures of 40 PSI and generates speeds from a crawl to 5500 RPM depending on the pressure applied to the foot control. The slow speed should be placed on the right side of the delivery system (dry side), as no coolant is needed for the slow speed procedures. As with the high speed handpiece, always read and follow manufacturer s instructions for operation, lubrication, cleaning, and sterilization for the slow speed motor and attachments. FORWARD/REVERSE RING Slow-Speed Handpiece Nose Portion Swivels 360 To Reduce Hand Fatigue Non-Retraction Water Relay Valve 16 5
8 To attach prophy angles, contra angles, cutting wheels or handpiece burs to the handpiece, simply turn lock ring to unlock position slide in prophy angle then turn to lock position. Please note: If the prophy angle ever gets stuck, once you have removed it you can squirt a little Once A Day Spray Lubricant into the bottom of the prophy angle. This should help resolve the problem. CAUTION: Do not run slow-speed unless an angle or bur is installed as serious chuck damage will result. CLEANING OF HIGH-SPEED and SLOW-SPEED HANDPIECES Before cleaning procedures the bur must be removed from the handpiece. The handpiece must be cleaned with a brush or wiped with alcohol after each patient. Never use any type of chemicals to clean these handpieces. This includes Nolvasan, Roccal D, chemicals used in Ultrasonic cleaners. These cleaners will ruin the turbines and bearings in the handpieces. STERILIZATION OF HIGH and SLOW-SPEED HANDPIECES 1. The handpiece must be sterilized by autoclave for 15 minutes at 135 C (275 F). Do not exceed 275 F when autoclaving. 2. Only use non chlorine products, and no chemical solutions. 3. Do not sterilize the high speed handpiece with the bur inserted. Also, never sterilize the low speed with the prophy angle attached. 4. Always lubricate the handpieces before you autoclave them, then once handpiece has returned to room temperature you should lubricate it again. REPAIR AND REPLACING THE HIGH-SPEED CARTRIDGE Only use the original replacement turbines, for total assurance of quality control and product life. The cartridge is a fragile instrument. Please call our service department if you have questions or need help in replacing this part. DA400RC Standard Type Turbine DA400RCA Push Button Turbine w/cap DASKA485 Push Button Turbine Only 3-Way IC Syringe 6 15
9 Old Diagram Deleted. No New diagram. What would you like to do with this page WATER COOLANT ADDING WATER TO DENTAL SYSTEM Slowly remove water bottle from pressure manifold assembly and add distilled water only. Leave approximately two inches of air space at the top. Replace bottle, tighten until secure. AIR / WATER SYRINGE All of our dental stations come with an air / water syringe installed and ready to use. Depress the left button for water only. Depress the right button for air only. Depress both buttons to get a mist spray. MAINTENANCE OF THE DENTALAIRE DENTAL SYSTEMS COMPRESSOR Oil Change: Please change the oil in the compressor once a year. To change the oil, you want to start by taking the compressor out of the Cart Frame, unplugging the black power cord and main Air line then remove the white cover off of the compressor by removing the six bolts at the bottom. Now tilt the compressor away from you and unscrew the site glass indicator. Tip the compressor forward and pour the oil into a small bucket or coffee can. Next screw the site glass back on. Put the white cover back over the compressor and screw in the six bolts. 7
10 Please refer to our Compressor Maintenance Guide Chart below to help you keep the compressor running in top form. COMPRESSOR MAINTENANCE GUIDE CHART service and maintenance log Service Performed 1. Initial Installation Date Serviced By AIR / WATER SYRINGE Air or water leakage from the syringe is due to either worn or defective O-Rings or button assemblies. To rebuild syringe first remove the pin on the side of the housing, and then simply pull out the button straight out of the syringe head. Remove all water deposits off buttons & cylinders. Lubricate the buttons with a non-petroleum based lubricant. Reinstll the Air/Water buttons. Reinsert the pin through houing. Syringe Rebuild Kit Item # A ORAL ILLUMINATION This refers to the high speed handpieces that have a fiber-optic system. This unit will periodically require a change in the Halogen Light Bulb. Here s how to change the bulb: 1. Please make sure you are wearing gloves (before) handling the new bulb. The oils from your body will ruin the new halogen bulb. 2. Slide both sleeves back from the connector nut exposing bulb on side of housing. 3. Remove old bulb. 4. Install new bulb. 5. Place bulb back into housing 6. Slide sleeve over housing.. 7. Reinstall high speed handpiece. 8 13
11 DA400FOB - Fiber-optic Halogen Replacement Bulb Changing bulb on High-speed Handpiece TROUBLE SHOOTING GUIDE I. NO COOLANT WATER Water bottle empty. Flow control knob is closed. On / Off toggle is off. High speed handpiece is in the low speed position Faulty water relay valve. Plugged coolant port in handpiece II. COOLANT WATER DOES NOT SHUT OFF Faulty water relay valve. Water On / Off toggle left on III. COOLANT WATER LEAKING FROM HANDPIECE Missing or damaged handpiece connector gasket. Faulty water relay valve. Slow speed handpiece is in the high speed position. IV. MORE THAN ONE HANDPIECE RUNS AT THE SAME TIME Handpieces are not positioned all the way down in the holders. Faulty auto block diaphragm. V. AIR / WATER SYRINGE PROBLEMS Water drips from tip. a) Faulty valve core Button blow out. a) Tip is plugged at the end. 9
12 b) Tip is not installed all the way into the into the Air Water Sprayer. (Loosen nut, press tip further into connector and tighten nut while holding the tip in) c) Faulty o-ring in tip adapter. 3. Air or water leaks from buttons when in use. a) Faulty buttons. 4. Low air or water flow cont: a) Improper regulator adjustment b) Empty water bottle c) Kinked supply tubing. d) Plugged tubing. e) Plugged syringe head VI. FOOT CONTROL HISSES 1. Faulty foot control popped valve. 2. Foot control tubing connected backwards. VII. HANDPIECE TUBING BLOWS OFF 1. Handpiece has been over pressurized. VIII. COMPRESSOR WON T TURN ON 1. Check power source. Check tank pressure (compressor will not turn on if tank is fully pressurized). 3. Faulty starting capacitor (replace). 4. Compressor is over-heated and the thermal safety switch is off. (Let unit cool and it will come on automatically, usually in minutes). IX. HANDPIECE LACKS POWER 1. Inadequate tank pressure. 2. Improper regulator pressure (reset regulator). 3. Improper individual handpiece pressure adjustment. 4. Faulty foot control. 5. Handpiece connector gasket is missing. 6. Directional selector ring is not rotated all the way into forward or reverse. (Slow speed handpiece only) 7. Faulty handpiece tubing. X. COMPRESSOR RUNS, BUT WON T PRESSURIZE FULLY 1. Plug is on the air inlet. Replace with air filter. 2. Compressor tank drain valve is leaking air. 3. Faulty check valve between compressor and filter tank. XI. COMPRESSOR OVERHEATS 1. Air inlet is plugged. 2. Handpiece pressure is set too high Handpiece has been run for too long a time and the 50% duty cycle has been exceeded. XII. UNIT IS PRESSURIZED BUT HANDPIECE DOES NOT RUN 1. Regulator pressure is low or off. 2. Supply tubing from regulator to control head is kinked. 3. Faulty foot control. 4. Handpiece directional ring is between forward and reverse (slow speed handpiece only). 5. Faulty handpiece turbine. TROUBLE SHOOTING GUIDE FOR BUILT IN AMDENT PIEZO SCALER I. THE SCALER WON T RUN 1. Check main power, main fuse, On / Off Switch. II. WEAK OR NO TIP VIBRATION 1. Increase the power control setting. 2. Check to see if tip is tightened properly. 3. The tip is worn out, replace with new tip. 4. Change to a new handpiece. 5. Faulty air switch. 6. Change back to the old handpiece and then replace the electronic part. 7. Replace both the handpiece and electronic part. III. INSUFFICIENT WATER SPRAY 1. Turn the knob to full open position. 2. Check / replace water filter. 3. Check all water connections. Be sure there is no leakage or kinked tubing. 4. Remove the tip, if the water is dripping from the handpiece, replace the tip. 5. Check the delivery unit s control block that activates the water out to the scaler handpiece is working properly. FOOT CONTROL TO ULTRASONIC PIEZO SCALER This foot pedal has two buttons, one large and one small. The large button is for operating the high and low speed handpieces. The small button is for operating the piezo scaler only. 11
Dentalaire Owner s Manual for all Dental Stations
Dentalaire Owner s Manual for all Dental Stations DENTALAIRE SET UP PROCEDURE FOR DENTALAIRE DENTAL STATIONS STEP # 1 - Open crate using a large screwdriver. Please check crate for any damages and report
Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09
Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 1402 Congratulations! All of us at Summit Dental Systems want you to know that your 1402 Delivery Unit has been built with the finest
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
Procenter Delivery System* Troubleshooting Charts
1 2 3 4 Procenter Delivery System* Troubleshooting Charts * includes International (Whip) Units Component Page Procenter / Int l. (Whip) Delivery Units*... 2 Assistant s Units...6 Midmark Cuspidor...7
MP-4V Heavy Duty Riveter / 39048
MP-4V Heavy Duty Riveter / 39048 This newly designed heavy-duty air/hydraulic riveter is ergonomically designed with the professional in mind. The light weight 3.7 lbs. well balanced MP-4V includes a Vacuum
Installation Operation Maintenance Troubleshooting
Installation Operation Maintenance Troubleshooting Version 3, 2.1, June/09 Apr/09 1416 1402 Table of Contents Important information 2 Weights & Dimensions 3 Operator s Instructions 4 Flow Diagram 5 Purging
Global Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 6 Tipping Bucket: RG200 02/05/10 01-343 - 1 - Congratulations on your
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
MAC FAUCETS. Owner s Manual. Models: FA444
MAC FAUCETS Owner s Manual Models: FA444 Installation procedure: 1. Take a moment to view drawings and read special Installation note on page 3 of this manual before proceeding with installation. Connect
Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE
NG0M Triple Threat 3-in- Game Table 3 IN GAME TABLE Thank 3 in Y Game Table Thank you for your purchase of our product. We work around the clock and around the globe to ensure that our products maintain
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Cleaning & Sanitisation
Cleaning & Sanitisation Notice: The information and/or procedures presented in the following demonstration(s) should be performed by a trained Water Cooler Service Technician only. Never attempt to service
Compressor Service & Maintenance Manual
Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance
Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA
Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 1607 DAYTONA Congratulations! All of us at Summit Dental Systems want you to know that your 1607 Daytona Cuspidor has been built with
USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172
Model # 900172: Page 1 USER MANUAL Bottom Loading Bottled Water Dispenser Model # 900172 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING
OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks
OWNER S MANUAL for FOOTWORKS tm Faucet Controller Foot Operated Faucet Control Valves for Commercial Sinks - 1 - Introduction Congratulations on your purchase of a FOOTWORKS tm Faucet Controller, an engineered
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
IMPORTANT SAFETY RULES TO FOLLOW
WARNING FLOOR & CARPET CLEANER Any piece of equipment can be dangerous if not operated properly. YOU are responsible for the safe operation of this equipment. The operator must carefully read and follow
SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE
VOLLEYBALL SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL Includes: OPERATION SETUP USE & CARE SERVICE REV032813 SPORTS ATTACK, LLC. 800-717-4251 sportsattack.com WARRANTY STATEMENT
BOWIE PUMPS OPERATION - MAINTENANCE
BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped
2 HP / 4 GALLON AIR COMPRESSOR OWNER'S MANUAL
2 HP / 4 GALLON AIR COMPRESSOR OWNER'S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result
PNEUMATIC PLANISHING HAMMER
PNEUMATIC PLANISHING HAMMER 94847 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. Distributed Exclusively by Harbor
Bottom Loading Water Dispenser
Bottom Loading Water Dispenser Model # 601000 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING DISPENSER. SAVE THIS MANUAL FOR FUTURE
PAINT SPRAY GUN WASHER
PAINT SPRAY GUN WASHER 94996 ASSEMBLY AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious
Multi-Pitch Pitching Machine USER MANUAL
Multi-Pitch Pitching Machine USER MANUAL TABLE OF CONTENTS Thank you for purchasing the Cimarron Multi-Pitch Pitching Machine. The Cimarron Multi-Pitch Pitching Machine is a high performance pitching machine
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping
Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November
Installation Instructions 6028.801
DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
Flat Bottom Long Ram Hydraulic Jack
Flat Bottom Long Ram Hydraulic Jack 3 Ton 8 Ton 36468 36469 ASSEMBLY & OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com TO PREVENT SERIOUS
Operator s Instructions
Operator s Instructions A-Series Dental Units Document 90070 Rev C 0/0 Operator s Instructions A-Series Dental Units Table of Content Operating Conditions... Storage & Shipping Conditions... Classifications...
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
FLUSHMATE FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual 503 and 504 Series
Owner s Service Manual 503 and 504 Series FLUSHMATE FLUSHOMETER - TANK SYSTEM 503 504 FLUSHMATE A Division of Sloan Valve Company 30075 Research Drive New Hudson, MI 48165 800-533-3460 248-446-5300 http://www.flushmate.com
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
Dive Rite 200 & 300 Bar Isolator Manifold Service Manual
Dive Rite 200 & 300 Bar Isolator Manifold Service Manual Principal Photography and Text by Pete Nawrocky Copyright 2003 Lamartek Inc. D/B/A Dive Rite 0 Warning This manual is only to be used as a guide
MODEL #12006. Introduction
THE ORIGINAL PECO POWER SPRAYER PECO OWNER S MANUAL MODEL #12006 (Q0080) Revised: 1/8/2014 PECO POWER SPRAYER MODEL #12006 TABLE OF CONTENTS SECTION PAGE SECTION PAGE INTRODUCTION - - - - - - - - - - -
MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions
06/2011 MBSAW Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper
OWNER S MANUAL Table Tennis Table Patent Pending
OWNER S MANUAL Table Tennis Table Patent Pending Be sure to write your model number and serial number here for future reference. You can find these numbers printed on the bottom of the table. MODEL # T8179
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
Arctic Leash Instruction Manual Alaskan Products Company LLC.
Retractable Cord Reel for Engine Block Heaters Arctic Leash Instruction Manual Alaskan Products Company LLC. INSTALLATION INSTRUCTIONS This instruction manual is a reference guide for installing and operating
Step-by-step instructions:
Spark plug thread repair for Ford Triton cylinder heads Step-by-step instructions: Identification Installation Verification Specifically designed and tested for 4.6L, 5.4L, and 6.8L 2 and 4 valve heads,
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
FLUSHOMETER - TANK SYSTEM
Owner s Service Manual 501-A Series FLUSHOMETER - TANK SYSTEM 501-A Series FLUSHMATE 501-A SERIES (D) (E) (C) 2 3 (B) 1 4 (F) (A) 6 5 List of Components for 501-A Series*: 1. Lower Supply Group w/hose
INSTALLATION MANUAL MODEL RP-100
INSTALLATION MANUAL FOR 24 VALVE 5.9L CUMMINS POWERED DODGE TRUCKS 2003 THROUGH 2004.5 MODEL RP-100 READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION 5400 BUSINESS 50 WEST SUITE 8 573 635-0555
Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930
Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930 WARNING Ultraviolet light is harmful to eyes and skin. Never look at light produced by this lamp. Unplug lamp before servicing. Electrical
Ozone Generator Manual
ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 Ozone Generator Manual 80003-118 MCN-282, 05/14/04 Table of Contents 1.0 INTRODUCTION... 1 1.1 Unpack...1 1.2 Check Order...1 1.3 Serial Numbers...1
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100] PLEASE READ BEFORE INSTALLATION TO PREVENT DAMAGE TO THE COOLER HOT WATER TANK STEAM EXAUST VENT (CAUTION!)
HYDRAULIC LIFT TABLE CART 2200-LB.
HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
Instruction Manual. www.aromaco.com AWK-115S
Hot H2O X-Press Electric Water Kettle Instruction Manual www.aromaco.com AWK-115S Congratulations on your purchase of the Aroma Hot H20 X-Press Kettle. This handy appliance provides more speed and convenience
SAFETY & OPERATING INSTRUCTIONS
SAFETY & OPERATING INSTRUCTIONS EDLUND TOMATO LASER, Models ETL -316, -140 & -380 READ AND UNDERSTAND THIS MANUAL AND ALL INSTRUCTIONS BEFORE OPERATING THIS SLICER. 159 Industrial Parkway, Burlington,
Manual for GlobePharma Mini-Press II Rotary Tablet Press
1 of 13 Preparing the Rotary Press 1. Make sure the rotary press is unplugged. 2. Open the bottom cabinet of the rotary press and take out the grey tool kit, and the beige box of punches and dies. 3. Take
accidents which arise due to nonobservance and the safety information herein.
20 GALLON COMPRESSOR Model: 7342 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry. This
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Troubleshooting Guide for Dispenser Model #900172
Troubleshooting Guide for Dispenser Model #900172 Q. The cold water is room temperature. A. There is a cold water thermostat control mounted to the back of the majority of our appliances. Simply unplug
tire inflator with pressure gauge
tire inflator with pressure gauge Model 95583 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks
ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.
ZAPPY 3 OWNER S MANUAL Read this manual completely before riding your Electric ZAPPY 3. TECHNICAL INFORMATION Model No. : ZAPPY 3 Product size Type of motor Motor power Battery type Battery Charger Charging
Auto-belay Cable Replacement Process
Auto-belay Cable Replacement Process Version 2.00 WARNING: The air pressure in the auto-belay system is what causes the cable to be retracted when releasing the cable or climbing the wall with the cable
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
20 GALLON WET DRY VACUUM
20 Gallon Wet & Dry Vacuum 110" Water Lift Vac Motor 24" Front Mount Squeegee Assembly 50' Cord Special Tip Pour Feature Warranty Contractor Tool Kit Includes: Wet p/u Tool, Dry p/u Tool, Crevice Tool,
MODEL E-AF. Drain Cleaning Machine. Operator s Manual
MODEL E-AF Drain Cleaning Machine Operator s Manual!!!! FOR YOUR SAFETY Before you operate or maintenance this equipment, READ this manual carefully and completely! Purchase Date: Serial Number: ELECTRIC
USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2
Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
IMPACT SPRINKLER TROUBLESHOOTING GUIDE
RAIN USE AND OPERATION BIRD IMPACT SPRINKLER TROUBLESHOOTING GUIDE The diagrams below depict typical Rain Bird sprinklers with all available controls. Your particular model may have only some of these
PEDAL CAR - GO CART ASSEMBLY & OPERATING INSTRUCTIONS
PEDAL CAR - GO CART 42822 ASSEMBLY & OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com Copyright 2000 by Harbor Freight Tools. All
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
APM HDC-4000 O PTICAL FIBER P OLISHING M ACHINE
Domaille Engineering LLC APM HDC-4000 O PTICAL FIBER P OLISHING M ACHINE USER S GUIDE Domaille Engineering, LLC 7100 Dresser Drive NE Rochester, MN 55906 Phone 507.281.0275 Fax 507.281.5694 www.domailleengineering.com
Model 854/856. Operating and Assembly Manual. Palmor Products Inc. 5225 Serum Plant Road Thorntown, IN 46071
Model 854/856 Operating and Assembly Manual Palmor Products Inc. 55 Serum Plant Road Thorntown, IN 46071 3/31/2015 SAFETY RULES Remember, any power equipment can cause injury if operated improperly or
Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function
Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless
Operator Manual 100 Series Coffee Grinders
Operator Manual 100 Series Coffee Grinders Models 100 and 190SS Model 100 Model 190SS Specifications...2 Safety Information...2 Installation...3 Operation...3 Table of Contents Cleaning & Maintenance...6
OPERATING INSTRUCTIONS FOR THE MODEL 210B-2 SRA
OPERATING INSTRUCTIONS FOR THE MODEL 210B-2 SRA SAFETY PRECAUTIONS FOR THE MODEL 210B-2 SRA System Under Pressure: Shut off air supply and disconnect air hose before disassembling or disconnecting parts.
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Line to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
Read This Before Operating The BaseHit
Read This Before Operating The BaseHit IMPORTANT OPERATING INSTRUCTIONS THE ACCURACY OF THE BASEHIT PITCHING MACHINE DEPENDS ON THE QUALITY, HARDNESS AND TYPE OF BALLS USED WITH THIS PRODUCT! TREND SPORTS
ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST
ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST Model 3-1.5B Model 45C Model 33B LORTONE 12130 Cyrus Way Mukilteo, WA 98275 (425) 493-1600 SETTING UP YOUR MACHINE For 45C Unit Only (33B & 3-1.5B already assembled)
Air Sleeve Maintenance
Air Sleeve Maintenance and Stuck-Down Troubleshooting Tools required: Safety glasses, gloves, strap wrench, shop towel, 1/4 -diameter 6 breaker bar, FOX High Pressure Pump, dental pick, hex wrench(es)
STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.
TABLE OF CONTENTS STAINLESS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 & JACKET ASSEMBLY... 4 SST Section 052506 1 Troubleshooting performed by untrained personnel could result in electrical
Watts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
GPS AutoSteer System Installation Manual
GPS AutoSteer System Installation Manual Supported Vehicles John Deere Sprayers 4720 4630 4730 4830 AutoTrac Ready PN: 602-0227-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS 106, 106-L 107, 107-L 108, 108-L 109-L ELEMENTARY
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions
LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment
Service Manual Rol-Lift
R 2000 Service Manual Rol-Lift Series: T and E Developed by Generic Parts Service This manual is intended for basic service and maintenance of the Rol-Lift pallet jack. The pallet jacks you are servicing
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Extra Tall Wide Span Gate
Extra Tall Wide Span Gate MODEL NO: 1154 Owner s Manual 11/19/2013_BL READ ALL INSTRUCTIONS BEFORE ASSEMBLY AND USE OF GATE. KEEP INSTRUCTIONS FOR FUTURE USE. www.regalo-baby.com... Regalo International,
Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas
Cleaning Instructions, Pilot Replacement and Valve Change Model No.: 233010 Natural Gas 8mm open-end wrench 9mm open-end wrench 10mm open-end wrench 12mm open-end wrench 13mm open-end wrench Phillips screw
ClearView 100. Instruction Manual
ClearView 100 Instruction Manual Important Safeguards This appliance is not intended for use by children or infirm persons without supervision. Young children should be supervised to ensure that they do
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Chapter 7 Hydraulic System Troubleshooting
Chapter 7 Hydraulic System Troubleshooting General The following troubleshooting information is provided as a general guide to identify, locate and correct problems that may be experienced with the hydraulic
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No: 0816407 Rev. 4 (07/12)
SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY
SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY 82-13-1 O-Ring (Rear) The Lead Screw Assembly is shipped separately. Note: Install Electrical and Pneumatic Circuitry. Be Sure electrical and pneumatic
User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:
User Manual Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included: 1: Display Console 1: Control Box 2: Encoder (Wires attached) (Not Shown) 1: 5v Power Supply
12-Volt Negative Ground Installation Instructions
12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for
STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES
GATE VALVE O.S. & Y 1.0 Periodic Inspections 1.1 The valve stem packing should be inspected at least monthly. If the stem packing shows signs of leakage, simply tighten the adjusting nuts to compress the
SMD Rework Station TABLE OF CONTENTS
SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating
Model MS-41BP 4G/ 15L. WARNING Carefully Read These Instructions Before Use 013529 R0514
Backpack Sprayer Use and Care Manual Model MS-41BP 4G/ 15L WARNING Carefully Read These Instructions Before Use 013529 R0514 WARNING WARNING: Improper use or failure to follow instructions can result in