1 PVG 120 Proportional Valves Technical Information
2 Contents Contents Function Hydraulic Systems Technical Data Electricqal Actuation Modul and Code Numbers Technicals Characteristics Dimensions Systemsafety Other Operating Conditions Conversion Factors Order Specifications Module Selection Chart General...3 Function...5 Hydraulic systems...7 Technical data...9 Electrical actuation Modules and code numbers PVP, pump side modules Accessory modules for PVP PVB, basic modules PVB, Accessories modules for PVB PVLP, shock and suction valve PVLA, suction valve PVBS, main spools PVM, mechanical actuation PVMD, PVH, cover for mechanically or hydraulically operated valve PVE, electrical actuation PVT, tank side modul PVAS, assembly kit Modules for oil flow exceeding 180 l/min [47.6 US gal/min] Technical characteristics Dimensions System safety Other operating conditions conversion factors Order specification Module selection chart Sauer-Danfoss. All rights reserved. Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer -Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without affecting agreed specifications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss, the Sauer-Danfoss logotype, the Sauer-Danfoss S-icon, PLUS+1, What really matters is inside and Know-How in Motion are trademarks of the Sauer-Danfoss Group. Frontpage: P , P , P , P , Drawing 155B L0356 Rev GE GD Mar Jul
3 General General Valve system Load sensing proportional valve type PVG 120 is a combined directional and flow control valve which is supplied as a valve group consisting of modules specified to match particular customer needs. The flexible nature of this valve will allow an existing valve bank to be easily adapted to suit changes in requirements. P General characteristics Load-independent flow control: - Oil flow to an individual function is independent of the load of this function - Oil flow to one function is independent of the load pressure of other functions Good regulation characteristics Central pilot supply built in when the valves are actuated electrohydraulically Energy-saving Up to eight basic modules per valve group Pump side module PVP Built-in pressure relief valve System pressure up to 400 bar [5800 psi] Pressure gauge connection Versions: - Open centre version for systems with fixed displacement pumps - Open centre version prepared for an extra relief module - Closed centre version for systems with variable displacement pumps - Closed centre version without system pressure relief valve for variable displace ment pumps with built-in pressure relief valve. Basic module PVB Integrated pressure compensator in channel P Interchangeable spools Depending on requirements the basic module can be supplied with: - Shock/suction valves - Adjustable LS pressure limiting valve for ports A and B - LS connection - Module for oil flows exceeding 180 l/min [47.6 gpm] - Different spool variants Actuation modules The basic module is always fitted with mechanical actuation PVM, which can be combined with the following as required: Electrical actuation - PVEH- proportional, high performance (11-32 V ) - PVEO - On/off (12 V or 24 V ) Cover for hydraulic remote control, PVH Cover for mechanically actuated valve group, PVMD 520L0356 Rev GE Mar
4 General General Remote controls units PVRE, electrical control unit, 162F Prof 1, 162F PVREL, electrical control unit, 155U PVRES, electrical control unit, 155B PVRH, hydraulic control unit, 155N 155B N N N N N0002 Electronic accessories EHF, low adjustment unit EHR, ramp generator EHS, speed control EHSC, closed loop speed control EHA, alarm logic EHC, closed loop position control 4 520L0356 Rev GE Mar 2009
5 Function PVG 120 with Open Centre PVP When the pump is started and the main spools (1) in the individual basic modules are in neutral position, oil flows from the pump, through connection P, across the pressure adjustment spool (2) to tank. The oil flow led across the pressure adjustment spool determines the pump pressure (stand-by pressure). If a reduced stand-by pressure is required, an extra relief valve PVPH or PVPE can be used in PVP (see characteristics for neutral flow pressure, page 25). When the main spools are actuated the highest load pressure is distributed across the shuttle valve circuit (3) to the spring chamber behind the pressure adjustment spool (2) and completely or partly closes the connection to tank. The pump pressure is applied to the right-hand side of the pressure adjustment spool (2). The pressure relief valve (4) opens when the load pressure exceeds the set value, allowing pump flow to be diverted back to tank. In the basic module the compensator (5) maintains a constant pressure drop across the main spool both when the load changes and when a module with a higher load pressure is activated. Shock and suction valves with a fixed setting (7) and the suction valves (8) on ports A and B are used to protect individual working functions against overload. In the basic module it is possible to build in an adjustable LS pressure relief valve (6) to limit the pressure from each working function. The LS pressure limiting valve saves energy: Without LS pressure limiting valve all the oil flow to the working function will be led across the combined shock and suction valves to tank if the pressure exceeds the fixed setting of the valves. With LS pressure limiting valve an oil flow of only about 2 l/min [0.5 US gal/min] will be led across the LS pressure limiting valve to tank if the pressure exceeds the valve setting. PVG 120 with Closed Centre PVP In the closed centre version an orifice (9) has been fitted instead of the plug. This means that the pressure adjustment spool (2) will only open to tank when the pressure in channel P exceeds the pressure relief valve setting (4). In load sensing systems the load pressure is led to the pump regulator via the LS connection (10). So the orifices (11) have been removed, and a plug (12) has been fitted instead of one of the orifices. In neutral position the pump regulator will set the displacement so that leakage in the system is just compensated for. When a main spool is activated, the pump regulator will adjust the displacement so that the set differential pressure between P and LS is maintained. The pressure relief valve (4) in PVP is set for a pressure of about 30 bar [435 psi] above maximum system pressure (set at the pump or an external pressure relief valve). If the system or the pump regulation has a pressure relief valve, it is possible to use a PVPV pump side module, without integrated pressure adjustment spool and pressure relief valve. 520L0356 Rev GE Mar
6 Function PVG 120 Sectional Drawing 1. Main spool 2. Pressure adjustment spool in PVP 3. Shuttle valve 4. Pressure relief valve in PVP 5. Pressure compensator in PVB 6. LS pressure relief valve in PVB 7. Shock and suction valve PVLP 8. Suction valve PVLA 9. Orifice, closed centre PVP Plug, open centre PVP 10. LS connection 11. Orifice, open centre PVP 12. Plug, closed centre PVP 6 520L0356 Rev GE Mar 2009
7 Hydraulic Systems Examples PVG 120 with fixed displacement pump 520L0356 Rev GE Mar
8 Hydraulic Systems Examples PVG 120 with variable displacement pump 8 520L0356 Rev GE Mar 2009
9 Technical Data PVG 120 Valve Group Port P continuous 350 bar [5075 psi] intermittent 1) 400 bar [5800 psi] Max. pressure Port A/B 400 bar [5800 psi] Port T, static/dynamic 25 bar/40 bar [365/580 psi] Oil flow, (see characteristics page 26) Port P, rated max. 240/300 l/min [63.4/79.3 gpm] 65/95/130/180/ [17.2/25.1/34.3/47.6/ Port A/B 210/240 l/min 2) 55.5/63.4 gpm 2)] Spool travel ± 8 mm [± 0.32 in] Dead band (± 25%) ± 2 mm [± 0.08 in] Max. internal leakage at 100 bar, 21 mm 2 /s Oil temperature (inlet temperature) A/B T, without shockvalve 90 cm 3 /min [5.5 in 3 /min] A/B T, with shockvalve 95 cm 3 /min [5.6 in 3 /min] Recommended temperature 30 to 60 C [86 to 140 F] Min. temperature 30 C [ 22 F] Max. temperature +90 C [+194 F] Ambient temperature 30 to +60 C [ 22 to +140 F] Operating range 12 to 75 mm 2 /s [65 SUS to 347 SUS] Oil viscosity Min. viscosity 4 mm 2 /s [39 SUS] Max. viscosity 460 mm 2 /s [2128 SUS] Filtering (See page 38) Max. contamination (ISO 4406) 23/19/16 Oil consumption in pressure reduction valve for PVT at PVE pilot-oil supply 0.4 l/min [0.1 gpm] 1) Intermittent operation: the permissible values may occur for max. 10% of every minute. 2) See page 24 regarding the ordering or conversion of valve groups for oil flows exceeding 180 l/min [47.6 gpm]. Mechanical Actuation PVM Regulation range, control lever ±19,5 Neutral position Max. spool travel Operating force Possible control lever positions (see page 31) 1) without voltage PVE PVM + PVMD PVM + PVE 1) PVM + PVH 2.8 ± 0.2 N m [24.8 ± 1.8 lbf in] 2.8 ± 0.2 N m [24.8 ± 1.8 lbf in] 4.7 ± 0.2 N m [41.6 ± 1.8 lbf in] Number ± 0.2 N m [35.5 ± 1.8 lbf in] 4.0 ± 0.2 N m [35.5 ± 1.8 lbf in] 12.8 ± 0.2 N m [113.3 ± 1.8 lbf in] Hydraulic Actuation PVH Control range 5 to 15 bar [75 to 220 psi] Max. pilot pressure, static 35 bar [510 psi] Max. pressure on port T 1) 3 bar [45 psi] 1) It is recommended that the tank connection from the hydraulic remote control unit PVRH is taken direct to tank. 520L0356 Rev GE Mar
10 Technical Data PVE Electrical Actuation Actuation PVEO ON/OFF PVEH Proportional High Hysteresis (applies to the electrical actuation only) 1) Typical - 4% Reaction time from neutral position to max. spool travel Typical 250 ms 250 ms Max. 350 ms 280 ms Reaction time from max. spool travel to neutral Typical 240 ms 150 ms position 2) Max. 330 ms 200 ms Pilot oil flow pr. PVE Neutral position without voltage 0 l/min / [US/gal min] Locked with voltage 3) 0 l/min / [US/gal min] Enclosure to IEC 529 IP 65 1) The hysteresis is stated at rated and f = 0,02 Hz for a cycle. One cycle includes the movement from neutral position to max. spool travel direction A, via neutral position to max. spool travel in direction B, and back to neutral position. Further information can be obtained by contacting the Sales Organization for Sauer- Danfoss. 2) Reaction times for PVEH is reduced by 20 by 30 ms if the voltage is not interrupted during the neutral positioning (remote control lever without neutral position switch). 3) Total oil consumtion for a spool movement from N to full A or B: l [ US gal] PVEO PVEO Supply voltage U DC range 11 V to 15 V 22 V to 30 V rated 12 V DC 24 V DC max. ripple 5% Current consumption at rated voltage V V Signal voltage (PVEM) neutral A-port B-port 0.5 x U DC 0.25 U DC to 0.75 U DC Signal current at rated voltage (PVEM) 0.25 ma 0.50 ma Input impedance in relation to 0.5 U DC Power consumption 12 KΩ 8 W PVEH PVEH Supply voltage U DC range 11 V to 32 V rated 11 V to 32 V max. ripple 5% Current consumption at rated voltage 0.57 (0.33) 12 V 0.3 (0.17) 24 V Signal voltage Signal current at rated voltage Input impedance in relation to 0.5 U DC Input capacitor Power consumption neutral A-port B-port 0.5 x U DC 0.25 U DC to 0.75 UDC 0.25 ma to 0.70 ma 12 KΩ 100 ηf 7 (3.5) W Max. load 100 ma 60 ma PVEH Active Passive Reaction time at fault Reaction time at fault 500 ms 250 ms L0356 Rev GE Mar 2009
11 Technical Data PVPE, Electrical Relief Valve, Normally Open Max. operation pressure Max. pressure drop a an flow of 0.20 l/min. [0.053 US gal/min] Oil temperature (inlet temperature) Max. coil surface temperature Ambient temperature Oil viscosity Response time for pressure relief to tank Recommended temperature Min. temperature Max. temperature Operating range Min. viscosity Max. viscosity 350 bar [5085 psi] 1.2 bar [17 psi] 30 to 60 C [86 to 140 F] 30 C [ 22 F] +90 C [+194 F] 155 C [311 F] 30 to +60 C [ 22 to +140 F] 12 to 75 mm2/s [65 to 347 SUS] 4 mm 2 /s [39 SUS] 460 mm 2 /s [2128 SUS] 600 ms Enclosure to. IEC 529 IP 65 Rated voltage 12 V 24 V Max.permissible deviation from rated supply voltage ± 10 % ± 10 % Current consumption at rated voltage at 22 C [72 F] coil temperature 1.55 A 0.78 A at 85 C [230 F] coil temperature 1.00 A 0.50 A Power consumption at 22 C [72 F] coil temperature 19 W 19 W at 85 C [230 F] coil temperature 12 W 12 W 520L0356 Rev GE Mar
12 Electrical Actuation PVEO, ON-OFF Main features of PVEO: Compact Robust operation With Hirschmann or AMP connector Low electrical power PVEH, Proportional High PVEH adjusts the main spool position so that it corresponds to an electrical control signal for example from a remote control unit. The control signal (set-point signal) is converted into a hydraulic pressure which moves the main spool. The position of the main spool is converted in the positional transducer (C) to an electric signal (feed-back signal). This signal is registered by the electronics. The variation between the set-point signal and feed-back signal actuates the solenoid valves. Thus the hydraulic pressure moves the main spool into the correct position. Special features of PVEH: Inductive transducer Integrated pulse width modulation Low hysteresis Fast reaction time Hirschmann or AMP connector Fault monitoring with transistor output for signal source Low electrical power No set-up procedure L0356 Rev GE Mar 2009
13 Electrical Actuation PVEH, LVDT-Transducer LVDT, Inductive transducer (Linear Variable Differential Transformer). When the main spool is moved a voltage is induced proportional to the spool position. The use of LVDT gives contact-free (proximity) registration of the main spool position. This means an extra-long working life and no limitation as regards the type of hydraulic fluid used. In addition, LVDT gives a precise position signal of high resolution. PVEH, Pulse Width Modulation Integrated pulse width modulation Positioning of the main spool in PVEH is based on the pulse width modulation principle. As soon as the main spool reaches the required position, modulation stops and the spool is locked in position. PVEH, Fault Monitoring A fault monitoring system is provided in all PVEA, PVEH and PVES modules. The system is available in two versions: The active fault monitoring type, which provides a warning signal, deactivates the solenoid valves and drives the spool in neutral. The passive fault monitoring type, which provides a warning signal only. Both active and passive fault monitoring systems are triggered by three main events: 1. Input signal monitoring The input signal voltage is continuously monitored. The permissible range is between 15% and 85% of the supply voltage. Outside this range the section will switch into an active error state. 2. Transducer supervision If one of the wires to the LVDT sensor is broken or short-circuited, the section will switch into an active error state. 3. Supervision of the closed loop The actual position must always correspond to the demanded position (input signal). If the actual spool position is further than the demanded spool position (>12%, PVEA: >25%), the system detects an error and will switch into an active error state. On the other hand, a situation where the actual position is closer to neutral than that demanded will not cause an error state. This situation is considered in control. When an active error state occurs, the fault monitoring logic will be triggered: Active fault monitoring A delay of 500 ms (PVEA: 750 ms) before anything happens. The solenoid valve bridge will be disabled and all solenoid valves will be released. An alarm signal is sent out through the appropriate pin connection. This state is memorized and continues until the system is actively reset (by turning off the supply voltage). Passive fault monitoring A delay of 250 ms (PVEA: 750 ms) before anything happens. The solenoid valve bridge will not be disabled but still control the main spool position. An alarm signal is sent out through the appropriate pin connection. This state is not memorized. When the erroneous state disappears, the alarm signal will turn to passive again. However, the signal will always be active for a minimum of 100 ms when triggered. 520L0356 Rev GE Mar
14 Electrical Actuation PVEH, Fault Monitoring (continued) To prevent the electronics from going into an undefined state, a general supervision of the power supply and the internal clock frequency is made. This function applies to PVEH - and will not activate fault monitoring: 1. High supply voltage The solenoid valves are disabled when the supply voltage exceeds 36 V, and the main spool will return/stay in neutral. 2. Low supply voltage: The solenoid valves are disabled when the supply voltage falls below 8.5 V, and the main spool will return/stay in neutral. 3. Internal clock The solenoid valves are disabled when the internal clock frequency fails, and the main spool will return/stay in neutral. WWARNING It s up to the customer to decide on the required degree of safety for the system (see PVE series 4 catalogue DKMH.PK.570.A1.02, page 19). Note: Different degrees of safety are described on pages 33 to 36. The fault monitoring does not work if the supply voltage to PVEH is cut off - for example by a neutral position switch (see page 33). When using PVEH with passive fault monitoring it is up to the customer to decide on the degree of safety required for the system (see page 33). Fault Monitoring Specification Type Fault monitoring Delay before error out Error mode Error output status Fault output on PVE 1) LED light Memory (reset needed) PVEO PVEH No fault monitoring Active Passive Flashing red No fault Low < 2 V Green ms Input signal faults Flashing red Transducer (LVDT) High U DC Yes Constant red Close loop fault No fault Low < 2 V Green ms Input signal faults Transducer (LVDT) High ~U DC No Constant red Close loop fault 1) Measured between fault output pin and ground L0356 Rev GE Mar 2009
15 Electrical Actuation PVEH, Connection to Fault Monitoring Output Green Transistor output function Normal A: External relay B: Solenoid valve (e.g. PVPE) Red Transistor output function Fault A: External relay B: Solenoid valve (e.g. PVPE) Via an external relay pin 3 can be connected to an electrically actuated valve which will relieve pump oil flow to tank, e.g. PVPE. Other connections possible: a valve to relieve the LS signal a signal lamp, an alarm horn pump cut-out, etc. 520L0356 Rev GE Mar
16 Modules and Code Numbers PVP and PVPV, Pump Side Modules Symbol Description Code number Open centre PVP for pumps with fixed displacement. Pressure gauge connection. Open centre PVP for oil flow exceeding 180 l/min. [47.55 US gallon/min] For pumps with fixed displacement. Pressure gauge connection. Metric flange SAE flange O-ring boss Metric flange SAE flange O-ring boss 155G G G G G G5028 Metric flange 155G5020 Closed centre PVP for pumps with variable displacement. Pressure gauge connection. SAE flange 155G5038 O-ring boss 155G5022 Metric flange 155G5030 Closed centre PVPV without pressure relief valve. For pumps with variable displacement. Pressure gauge connection SAE flange O-ring boss 155G G5031 Port connections: P = 1 in SAE flange (415 bar [6020 psi]); MA = G 1 /4; LS = G 3 /8 P = 1 1 /16-12 UN O-ring Boss 6020 psi; MA = 1 /2-20 UNF O-ring Boss; LS = 3 /4-16 UNF O-ring Boss L0356 Rev GE Mar 2009
17 Modules and Code Numbers PVP, Accessories for Open Centre Pump Side Modules Symbol Description Code number Prop, PVPD 155G5041 PVEH, hydraulically actuated relief valve 155G5061* (12 V ) 155G5052 PVPE, electrically actuated relief valve. Normally open solenoid valve (12 V ) 155G5054 * Connection for external pilot pressure: only available with G 1 / 4 thread 520L0356 Rev GE Mar
18 Modules and Code Numbers PVB, Basic Modules Symbol Description Code number No facilities for shock valves A/B (low modules) Facilities for shock valves A/B (high modules) Metric flange 155G G6005 Pressure compensated basic module SAE flange 155G G6007 O-ring boss 155G G6006 Port connections: A/B: 3/4 in SAE flange 415 bar [6020 psi]; A/B: 1 1/16-12 UN O-ring Boss 415 bar [6020 psi] L0356 Rev GE Mar 2009
19 Modules and Code Numbers PVB, Accessories for Basic Modules Symbol Description Code number PVBP, plug 155G6081 PVBU, module for oil flow exceeding 180 l/min [47.6 US gallon/min]. Connection for external LS pressure relief. 155G6035 PVBC, connection for external LS pressure relief. 155G6082 PVBR, LS-pressure relief valve for ports A/B-port 155G6080 Port connections: G 1 /4: only available with G 1 /4 thread 520L0356 Rev GE Mar
20 Modules and Code Numbers PVLP, Shock and Suction Valves for A and B Port Connections Symbol Fixed setting Code number bar [psi] 50 [725] 75 [1100] 100 [1450] 125 [1800] 150 [2200] 175 [2550] 200 [2900] 225 [3240] 250 [3650] 275 [4000] 300 [4350] 325 [4700] 350 [5100] 375 [5450] 400 [5800] 155G G G G G G G G G G G G G G G0400 PVLA, Suction Valve Symbol Code number 155G L0356 Rev GE Mar 2009
21 Modules and Code Numbers PVBS, Main Spools Symbol ISO Symbol Description Code number Size A 65 l/min [17.2 US gal/ min] B 95 l/min [25.1 US gal/ min] C 130 l/min [34.3 US gal/ min] D 1) 180 l/min [47.6 US gal/ min] 4-way, 3-position. Closed neutral position 155G G G G way, 3-position. Throttled, open neutral position 155G G G way, 3-position P B 155G G6478 1) Main spool D is used for oil flow exceeding 180 l/min [47.6 US gal/min] 520L0356 Rev GE Mar
22 Modules and Code Numbers PVM, Mechanical Actuation Symbol Description Code number PVM, standard, spring centered mechanical actuation G3040 Individual oil flow adjustment to ports A and B G3041 PVM, mechanical actuation for hydraulically operated valves. Individual oil flow adjustment to ports A and B G G3051 PVMD, Cover for Mechanical Actuation Symbol Description Code number PVMD, cover for purely mechanically operated valve 155G4061 PVH, Hydraulic Actuation Symbol Description Code number PVH, G 1/4 155G4022 cover for hydraulically operated valve. 1/2 in-20 UNF 155G4021 PVE, Electrical Actuation Symbol Description Code number Hirschmann AMP PVEO, ON/OFF 12 V 155G G V 155G G4284 PVEH, Proportional high. Puls width modulation, short reaction time, low hysteresis, active fault monitoring, inductive transducer 155G G4094 PVEH, Proportional high. Puls width modulation, short reaction time, low hysteresis, passive fault monitoring, inductive transducer 155G G L0356 Rev GE Mar 2009
23 Modules and Code Numbers PVT, Tank Side Modul Symbol Description Code number Upper part Upper part: Metric flange 155G7020 T LS PP LS -> T SAE flange 155G7022 P O-ring boss 155G7021 Upper part Upper part: Metric flange 155G7023 T LX PP LS -> LX-port SAE flange 155G7025 P O-ring boss 155G7024 Lower part Lower part: Mounting thread metric 155G7060 Without active elements Mounting thread UNF 155G7062 Lower part Lower part: Mounting thread metric 155G7040 PVE, pilot oil supply for electrical actuations. Filter mesh: 125µm Mounting thread UNF 155G7042 Lower part: Mounting thread metric 155G7043 PVH, pilot oil supply for hydraulic actuations. Filter mesh: 125µm Mounting thread UNF 155G7044 Port connections: T = 1 in SAE flange 210 bar [3045 psi]; PP = G 3/8 [ 3 /8 in SAE] LX = G 3/8 [ 3 /8 in SAE]. T = 15 /16-12 UN O-ring Boss 3045 psi; PP = 3 /4-16 UNF O-ring Boss; LX = 3 /4-16 UNF O-ring Boss PVAS, Assembly Kit Code number 155G 1 PVB 2 PVB 3 PVB 4 PVB 5 PVB 6 PVB 7 PVB 8 PVB Tie bolts and seals 155G G G G G G G G L0356 Rev GE Mar
24 Modules and Code Numbers Modules for Oil Flow Exceeding 180 l/min [47.6 US gal/min] Pump with fixed displacement l. Ordering: Order accessory module 155G6035, main spool D, and pump side modules 155G5027/155G5028/155G Conversion: In open centre systems a max. oil flow exceeding 180 l/min [47.6 US gal/min] is achieved by changing the following parts in the pump side and basic modules: Open centre pump side module a) Pressure adjustment spool b) The springs behind the pressure adjustment spool c) The plug behind the pressure adjustment spool Parts from kit 155G5035 may be used. Closed centre pump side module A closed centre pump side module can be changed into an upgraded open centre pump side module by means of kit 155G5035. Basic module a) Spring behind pressure compensator b) The plug behind the pressure compensator Spring and plug with code number 155G6035 (PVBU, accessory module). Pump with variable displacement 1. Ordering: Order accessory module 155G6035 and main spool D. 2. Conversion: In closed centre systems a max. oil flow exceeding 180 l/min [47.6 US gal/min] can be achieved by changing the following basic module parts: a) Spring behind pressure compensator b) The plug behind the pressure compensator The code number of the spring and plug is 155G6035 (PVBU, accessory module) L0356 Rev GE Mar 2009
25 Technical Characteristics General All characteristics and values in this are typical measured results. For the hydraulic system a mineral based hydraulic oil with a viscosity of 21mm 2 /s [102 SUS] and a temperature of 50 C [122 F] was used. PVP, Pump Side Module PVP, pressure relief valve characteristic The pressure relief valve is adjustable within the bar [ psi] range by means of a screw. PVP, neutral flow pressure in PVP, open centre U = PVP for PVB oil flow > 180 l/min [47.6 US gal/min] S = PVP, standard 520L0356 Rev GE Mar
26 Technical Characteristics PVB, Basic Module Oil flow characteristics A : 65 l/min [17.2 US gal/min] rated oil flow B : 95 l/min [25.1 US gal/min] rated oil flow C : 130 l/min [34.3 US gal/min] rated oil flow D : 180 l/min [47.6 US gal/min] rated oil flow D.I : 240 l/min [63.4 US gal/min] rated oil flow (Closed centre system with basic module for oil flow > 180 l/min [47.6 US gal/min]) D.II : 210 l/min [55.5 US gal/min] rated oil flow (Open centre system with basic module for oil flow > 180 l/min [47.6 US gal/min] and pump side module 155G5027/155G5028/155G5029). U S = Signal voltage U DC = Supply voltage L0356 Rev GE Mar 2009
27 Technical Characteristics PVB, Basic Module Load independent oil flow Pressure drop (Q) T in neutral position (spools with open neutral position) (p) The oil flow (Q) is shown as a function of the load (p). Pressure drop A/B T at full spool travel Pressure drop A/B T in neutral position (spools with open neutral position) 520L0356 Rev GE Mar
28 Technical Characteristics PVLP, Shock Valve (Pressure Relief Valve in PVLP) The shock valve PVLP is designed to absorb shock effects. Consequently, it shall not be used as a pressure relief valve. PVLP/PVLA, Suction Function PVLP/PVLA, suction function characteristics L0356 Rev GE Mar 2009
29 Dimensions Valve Dimensions C : 1 in SAE flange (210 bar) [1 in SAE flange/1 5 /16-12 UN O-ring Boss (3045 psi)] D : 3 4 in SAE flange (415 bar) [ 3 /4 in SAE flange/1 1 /16-12 UN O-ring Boss (6020 psi)] E : 1 in SAE flange (415 bar) [1 in SAE flange/1 5 /16-12 UN O-ring Boss (6020 psi)] F : G 1 4 [ 1 /2 in - 20 UNF] G : G 3 /8 [ 3 /4 in - 16 UNF] H : M12; 18 mm deep [ 7 /16-14 UNC; 0.7 in deep] J : M10; 17 mm deep [ 3 /8-16 UNC; 0.7 in deep] K : M10; 17 mm deep [ 3 /8-16 UNC; 0.7 in deep] M : M12; 18 mm deep [ 7 /16-14 UNC; 0.7 in deep] N : G 3 /8 [ 3 /4 in - 16 UNF] PVB L L1 L2 mm [in] mm [in] mm [in] 170 [6.69] [10.38] 255 [10.05] 237 [9.33] [13.02] 322 [12.69] 304 [11.97] [15.66] 389 [15.33] 371 [14.61] [18.30] 456 [17.97] 438 [17.24] [20.94] 523 [20.61] 505 [19.88] [23.58] 590 [23.25] 572 [22.51] [26.22] 657 [25.89] 639 [25.16] [28.86] 724 [28.53] 520L0356 Rev GE Mar
30 Dimensions General Dimensions F : G 1 /4 [ 1 /2 in - 20 UNF] * Dimensions in parenthesis apply to high basic modules L0356 Rev GE Mar 2009
31 Lever Positions PVM, Lever Positions Base with an angle of 37.5 Base with an angle of L0356 Rev GE Mar
32 System Safety Building in Safety All makes and all types of directional control valves (incl. proportional valves) can fail. So for each application the necessary protection against the consequences of function failure should be built in. For each application an assessment should be made of the consequences of pressure failure and uncontrolled or blocked movements. To determine the degree of protection that ought to be built into the system, Sauer- Danfoss makes the following distinctions: 1. Maximum safety demands 2. High safety demands 3. Average safety demands 4. Limited safety demands See examples on pages 33, 34, 35 and L0356 Rev GE Mar 2009
33 System Safety 1. Maximum Safety Demands When the fault monitoring system in PVEH is connected, the reaction to electrical and mechanical faults (e.g. a spool seizure) is fast and operator-independent. See page 13 fault monitoring. A system can be protected against many electrical, hydraulic and mechanical faults by building in components as shown in the diagram: R: Alarm logic EHA (or relay) connected to the fault monitoring system in PVEH E: Electrical emergency stop M: Solenoid valve C: Pilot-operated check valve The alarm logic EHA (or relay) cuts off current to the solenoid valve (M) when PVEH monitoring registers a fault. The solenoid valve then leads the oil flow direct from pump to tank. Thus all functions are without operating pressure, i.e. locked in position, because there is no pilot pressure on the pilot operated check valve (C). Activation of the emergency switch (E) cuts off current to the proportional valve and the solenoid valve (M). Activation in this case is manual, but the result is the same as just described. Stopping or disconnecting the pump drive motor is another safety measure, if the system reaction time can be accepted. The neutral position switch in the remote control units should not be used. PVEH with fault monitoring must have a constant voltage supply. 520L0356 Rev GE Mar
34 System Safety 2. High Safety Demands Compared with the safety method previously described (1) this is operator-dependent and includes a neutral position switch (N). The neutral position switch cuts off current to the proportional valve automatically when the remote control lever is in neutral position. At the same time the neutral position switch cuts off fault monitoring in PVEH. So PVEH does not give a fault signal when for example the neutral positioning of the main spool fails L0356 Rev GE Mar 2009
35 System Safety 3. Average Safety Demands The difference in method now is that the LS signal from the proportional valve is led direct to tank when the emergency switch (E) is activated. The diagram shows the method used in a system with a fixed displacement pump, i.e. with open centre version proportional valve. Activation of the emergency switch makes the system pressure drop to bar [ psi]. For valve groups with oil flows > 180 l/min [47.6 US gal/min]) the system pressure drop to (20-26 bar [ psi] All functions requiring a higher operating pressure will stop. In LS systems with a variable displacement pump and closed centre proportional valve, the pressure after the LS relief depends on the pump stand-by pressure. 520L0356 Rev GE Mar
36 System Safety 4. Limited Safety Demands This safety system can consist of an emergency switch (E) and a neutral position switch (N) if protection against electrical failure is the only requirement. Here, there is no protection against hydraulic and mechanical faults (e.g. spool seizure in extreme position) L0356 Rev GE Mar 2009
37 Other Operating Conditions Oil The main duty of the oil in a hydraulic system is to transfer energy; but it must also lubricate the moving parts in hydraulic components, protect them against corrosion, and transport dirt particles and heat out of the system. It is therefore important to choose the correct oil with the correct additives. This gives problem-free operation and long working life. Mineral oil For systems with PVG 120 valves Sauer-Danfoss recommends the use of mineral-based hydraulic oil containing additives: Type H-LP (DIN 51524) or HM (ISO 6743/4). Non-flammable fluids Phosphate-esters (HFDR fluids) can be used without special precautions. However, dynamic seals must be replaced with FPM (Viton) seals. Please contact the Sauer- Danfoss Sales Organisation if the PVG 120 valve is to be used with phosphate-esters. The following fluids should only be used according to agreement with the Sales Organisation for Sauer-Danfoss: Water-glycol mixtures (HFC fluids) Water-oil emulsions (HFB fluids) Oil-water emulsions (HFAE fluids) Biodegradable oils PVG 120 valves can be used in systems using rape-seed oil. The use of rape-seed oil is conditional on - it complying with the demands on viscosity, temperature and filtration etc. (see chapters below and technical data page 9). - the operating conditions being adapted to the recommendations of the oil supplier. Before using other biodegradable fluids, please consult the Sauer-Danfoss Sales Organisation. Particle Content, Degree of Contamination Oil filtration must prevent the particle content from exceeding an acceptable level, i.e. an acceptable degree of contamination. Maximum contamination for PVG 120 is 23/19/16 (see ISO 4406). Calibration in accordance with the ACFTD method. In our experience a degree of contamination of 23/19/16 can be maintained by using a filter fineness as described in the next section. 520L0356 Rev GE Mar
38 Other Operating Conditions Filtering Effective filtration is the most important precondition in ensuring that a hydraulic system performs reliably and has a long working life. Filter manufacturers issue instructions and recommendations. It is advisable to follow them. System filters Where demands for safety and reliability are very high a pressure filter with bypass and indicator is recommended. Experience shows that a 10 µm nominal filter (or finer) or a 20 µm absolute filter (or finer) is suitable. It is our experience that a return filter is adequate in a purely mechanically operated valve system. The fineness of a pressure filter must be selected as described by the filter manufacturer so that a particle level of 23/19/16 is not exceeded. See Particle content, degree of contami-nation. The filter must be fitted with pressure gauge or dirt indicator to make it possible to check the condition of the filter. In systems with differential cylinders or accumulators the return filter must be sized to suit the max. return oil flow. Pressure filters must be fitted to suit max. pump oil flow. Internal filters The filters built into PVG 120 are not intended to filter the system but to protect important components against large particles. Such particles can appear in the system as a result of pump damage, hose fracture, use of quick-couplings, filter damage, starting up, contamination, etc. The filter that protects the pilot supply in the tank side module has a mesh of 125 µm. It is obtainable as a spare part and is easy to replace. The filter protecting the essential PVE parts has a mesh of 125 µm. Conversion Factors 1 Nm = lbf in 1 N = lbf in 1 bar = psi 1 mm = in 1 cm 3 = in 3 1 l = 0.22 gallon, UK 1 l = gallon, US F = 1.8 C L0356 Rev GE Mar 2009
39 Order Specification Order Form An order form for Sauer-Danfoss PVG 120 hydraulic valve is shown on next page. The form can be obtained from the Sauer-Danfoss Sales Organisation. The module selection chart on the next page and the order form are divided into fields. Each module has its own field: 0: PVP, pump side modules d: PVPD, PVPH and PVPE, accessory modules 1-8: PVB, basic modules e: PVBS, main spools f: PVBP, PVBR, PVBU and PVBC, accessory modules a: PVM, mechanical actuation c: PVMD, cover for mechanical operation PVH, cover for hydraulic operation PVEO and PVEH, electrical actuations b: PVLP, shock and suction valve PVLA, suction valve 9: PVT, tank side module 10: PVAS, assembly kit Please state: Code numbers of all modules required Required setting (p) for pump side module Required setting of LS A/B pressure relief valves, if accessory module PVBR is ordered. 520L0356 Rev GE Mar
40 Order Specification Order Form Reordering The space at the top right-hand corner of the form is for Sauer-Danfoss to fill in. The code number for the whole of the specified valve group (PVG No.) is entered here. In the event of a repeat order all you have to do is enter the number Sauer-Danfoss has given on the initial confirmation of order. If PVG 120 is to be used with phosphate-esters this must be stated on the order form (see also page 37, Non-flammable fluids ). Subsidiary / Dealer PVG No. PVG 120 Specification Sheet Customer Customer No. Application Revision No. Function A-Port 0 155G 155G B-Port p = bar a 155G 1 155G 155G e 155G c b 155G f 155G LSAB bar 155G b a 155G 2 155G 155G e 155G c b 155G f 155G LSAB bar 155G b a 155G 3 155G 155G e 155G c b 155G f 155G LSAB bar 155G b a 155G 4 155G 155G e 155G c b 155G f 155G LSAB bar 155G b a 155G 5 155G 155G e 155G c b 155G f 155G LSAB bar 155G b a 155G 6 155G 155G e 155G c b 155G f 155G LSAB bar 155G b a 155G 7 155G 155G e 155G c b 155G f 155G LSAB bar 155G b a 155G 8 155G 155G e 155G c b 155G f 155G LSAB bar 155G b Remarks 9 155G G G Filled in by Date 991L1868 ver L0356 Rev GE Mar 2009
41 Notes Notes 520L0356 Rev GE Mar
42 Module Selection Chart PVB, high basic module SAE O-ring Metric Weight flange Boss flange kg [lb] Facilities for shock valves AB 155G G G [22.5] PVB, low basic module SAE O-ring Metric Weight flange Boss flange kg [lb] No facilities for shock valves AB 155G G G [19.6] Accessory modules for PVB Weight kg [lb] Plug, PVBP 155G [0.9 ] LS A/B press. relief valve, PVBR 155G [0.9 ] External LS connection, PVBC 155G [0.9 ] Module for oil flow > 180 l/min [47.6 US gal/min], PVBU 155G [0.9 ] PVBS, mechanical actuation Oil flow l/min US gal Symbol A 65 [17.2] B 95 [25.1] C 130 [34.3] B 180 [47.6] 155G G G G G G G G G6478 Weight kg 0.35 [lb] [0.8] 0.35 [0.8] 0.35 [0.8] 0.35 [0.8] PVM, mechanical actuation PVM + PVMD or PVM + PVE PVM + PVH PVT, tank side module 155G G G G3051 SAE flange Weight kg [lb] 0.5 [1.1] O-ring Boss Metric flange Weight kg [lb] Upper part excl. LX connection 155G G G [10.1] Upper part incl. LX connection 155G G G [10.1] Lower part incl. pilot oil supply PVE for 155G G [9.7] Lower part excl. pilot oil supply for PVE 155G G [9.7] Lower part incl. pilot oil supply for PVH 155G G [9.7] L0356 Rev GE Mar 2009
43 Module Selection Chart PVP, pump side module Open centre Closed centre O-ring Boss SAE flange Metric flange Weight kg [lb] Excl. PVPD, PVPH, PVPE 155G G G [22.1] For PVB-oil flow > 180 l/ min [47.6 US gal/min] 155G G G [22.1] Excl. PVPD, PVPH, PVPE Incl. pressure relief valve and plug PVPD 155G G G [22.5] Excl. pressure relief valve 155G G G [24.3] Accessory modules for open centre PVP Weight kg [lb] Plug, PVPD 155G [0.9] Hydraulic relief valve, PVH 155G [1.1] Electrical 12 V 155G [1.5] relief valve, PVPE 24 V 155G [1.5] PVAS, assembly kit PVH, cover for PVRHH Weight kg [lb] 1/2 in - 20 UNF 155G [0.9] G 1/4 155G [0.9] Electrical actuation PVE PVMD, cover for PVM Weight kg [lb] 155G [0.7] PVEH Connector V PVEO Fault monitoring Active Passive 12 V 24 V Hirschmann 155G G G G4274 AMP 155G G G G4284 Weight kg [lb] [2.76] [2.76] [2.2] [2.2] PVLA suction valve A/B Weight kg [lb] 155G [0.4] PVB s G G G G G G G G8038 Weight kg [lb] [1.8] [2.2] [2.4] [2.6] [3.1] [3.7] [4.2] [4.6] PVLP, shock and suction valve A/B Pressure setting bar [psi] 50 [725] 155G [1100] 155G G G G G G G G G G G G G G0400 Weight kg [lb] [0.386] 520L0356 Rev GE Mar
44 Our Products Open circuit axial piston pumps Gear pumps and motors Fan drive systems Closed circuit axial piston pumps and motors Bent axis motors Hydrostatic transmissions Transit mixer drives Hydrostatic transaxles Electrohydraulics Integrated systems Microcontrollers and software PLUS+1 GUIDE Displays Joysticks and control handles Sensors Orbital motors Inverters Electrohydraulic power steering Hydraulic power steering Hydraulic integrated circuits (HIC) Cartridge valves Directional spool valves Proportional valves Sauer-Danfoss Hydraulic Power Systems Market Leaders Worldwide Sauer-Danfoss is a comprehensive supplier providing complete systems to the global mobile market. Sauer-Danfoss serves markets such as agriculture, construction, road building, material handling, municipal, forestry, turf care, and many others. We offer our customers optimum solutions for their needs and develop new products and systems in close cooperation and partner ship with them. Sauer-Danfoss specializes in integrating a full range of system components to provide vehicle designers with the most advanced total system design. Sauer-Danfoss provides comprehensive worldwide service for its products through an extensive network of Authorized Service Centers strategically located in all parts of the world. Local address: Sauer-Danfoss (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: Fax: Sauer-Danfoss GmbH & Co. OHG Postfach 2460, D Neumünster Krokamp 35, D Neumünster, Germany Phone: Fax: Sauer-Danfoss ApS DK-6430 Nordborg, Denmark Phone: Fax: Sauer-Danfoss-Daikin LTD Sannomiya Grand Bldg. 8F Isogami-dori, Chuo-ku Kobe, Hyogo , Japan Phone: Fax: L0356 Rev GE Mar
PVG 32 Proportional Valves. Technical Information
PVG 32 Proportional Valves Technical Information Contents General Function Technical Data General...4 Function...7 PVG 32 valve group...7 PVPC, plug for external pilot oil supply...9 PVMR, friction detent...
Joystick PVRES and PVREL. Technical Information
Joystick PVRES and PVREL Technical Information Contents Revision History PVRES General PVRES Accessories PVREL General Table of Revisions Date Page Changed Rev Mar 2003 All First edition AA May 2010 16
Series TMM Axial Piston Motor. Technical Information
Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer
Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
PLUS+1 GUIDE Software. PLUS+1 Compliant H1 Filter Bypass Function Block User Manual COMPLI ANT. 158.2 mm 6.23. 144.5 mm 5.69. 2x 25.2 mm [1.
PLUS+1 GUIDE Software PLUS+1 Compliant H1 Filter Bypass Function Block 158.2 mm 6.23 144.5 mm 5.69 142.0 mm [5.59] 2x 25.2 mm [1.0] 97.0 mm [3.82] TM 2x 7.0 [.28] MOUNTING DIRECTION #2 COMPLI ANT PIN #1
D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05
D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General
The PLUS+1 Control Platform. Productivity and Performance
The PLUS+1 Control Platform Productivity and Performance Taking Mobile Machine Control to the Next Level The OEM design environment continues to become more challenging, every day, every year. Vehicle
Variable Displacement Pump AA10VSO
Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi
DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30
85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08
D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10
D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 OVERVIEW D660 Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Electronics
DSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05)
83 280/112 ED DSE5J DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) p max 320 bar Q max 180 l/min MOUNTING SURFACE OPERATING
Chapter 5: Flow Valves
Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free
RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007
Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid
1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING
1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: [email protected] 1115 4G
Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min
Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device
HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999
CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.
Pressure Relief and Regulating Valves
Pressure Relief and Regulating Valves With blocked center directional valves and variable displacement pumps, or open center directional valves and fixed displacement pumps where fast response, low leakage
Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement
Program Summary Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement 2 Table of content Content Fluid & Motion Control 3 Directional Control Valves, solenoid operated 4 Directional
Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional
"A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type
Single Pump, "OBE" Type Electro-Hydraulic Proportional & Flow Type Input Signal for Safety valve Input Signal for Flow Amplifier Proportional Solenoid Sensor Valve Piston (S Input Voltage L) Performance
Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB.. 1.1 Generals. 1.2 Application examples. 2.2 3-way flow control. 2.1 2-way flow control
Flow Control Valve Series SRCB.. plug-in solenoid for easy coil change flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports energy - optimised
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors
European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for
Displays 2 x 24 Character Serial Display Module
MAKING MODERN LIVING POSSIBLE Technical Information Displays 2 x 24 Character Serial Display Module powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev November 2015 Converted
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications
VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
Smart. Productivity and performance The PLUS+1 control platform. powersolutions.danfoss.com. control systems MAKING MODERN LIVING POSSIBLE
MAKING MODERN LIVING POSSIBLE Productivity and performance The PLUS+1 control platform Smart control systems bring your machines faster, more efficiently to market powersolutions.danfoss.com Taking mobile
SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711
A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.
COUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and
Example. Fluid Power. Circuits
Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) Type 4WRPEH 6 Size (NG) 6 Unit series 2X Maximum working pressure
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
Fixed displacement vane pumps
Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double
KDG3V-5/7/8, 10 Series
Vickers roportional Valves KDG3V-5/7/8, 1 Series Single-Stage with Hydraulic ilot Operation High Flow roportional Directional Control Valves asic Characteristics Max. pressure.......... up to 35 bar (5
Hydraulic Flow Control Valves
Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series
3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
Load-sensing control block in mono and sandwich plate design
Load-sensing control block in mono and sandwich plate design RE 64276/08.2010 Replaces: 08.2008 1/64 Type M4-12 Nominal size 12 Unit series 2X Nominal pressure 350 bar (pump side) Nominal pressure 420
3/2 Solenoid Cartridge Valve, Size 6
/ Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
www.curtisinstruments.com
CANBUS I/O EXPANSION MODULE MODELS 56 / 56P FEATURES Eighteen multi-purpose I/O pins provide simple, flexible vehicle control system expansion. Two high-frequency (A, A) PWM driver outputs support a variety
4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual
Data sheet ECC 12 and 22
Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe
Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division
Parker Piston Pumps Otsego Core Competency... Piston Pumps PAVC Series : 4 displacements from 33-100 cc/r, 207 Bar, 3000 RPM PVP Series : 9 displacements from 16-140 cc/r, 250 Bar, 3000 RPM PV Plus : 12
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS Hydraulic components POCLAIN HYDRAULICS Methodology : This document is intended for manufacturers of machines that incorporate Poclain Hydraulics products.
3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
Multi-function Card. 1 Description. 2 Technical data ESSK 107. 1.1 General. 1.2 Application example
Multi-function Card ESSK 107 semiconductor output stages 3 power outputs 1 current measurement input 2 analogue / digital inputs 1 digital input 5 adjustments power supply 12... 30 V 1 Description 1.1
2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
PRE3G 81 250/212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12
81 250/212 ED PRE3G PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS SUBPLATE MOUNTING ISO 4401-03 (CETOP 03) p max 350 bar Q max 40 l/min MOUNTING SURFACE OPERATING
Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM
Page 1 of 19 Cat Electronic Technician 2015A v1.0 Product Status Report 2:49 PM Product Status Report Parameter Value Product ID WRK00337 Equipment ID WRK00337 Comments A01-52 C9 330D (THX37891) Parameter
Introduction to Process Control Actuators
1 Introduction to Process Control Actuators Actuators are the final elements in a control system. They receive a low power command signal and energy input to amplify the command signal as appropriate to
Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)
Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
scx-180 Control focused technology driven SCX valve series SSL-1000 REV 04/09 - SUPERCEDES REV 01/08
Control focused technology driven SCX valve series scx-18 SSL-1 REV 4/9 - SUPERCEDES REV 1/8 Table of Contents Page Technical Specifications 3 SCX-18 Cut Aways 4 Technical Description, Product Features
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
Dual Path Mobile Pump
Dual Path Mobile Pump Technical Manual 350 Series 350 Series Mobile Pump Introduction Single Assembly* Dual Path Assembly The 350 Series mobile pump is an advanced, closed circuit, servo controlled, axial
Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93
Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
The Professional Choice. LDC With DC motor. OLAER LDC optimized for mobile use
The Professional Choice LDC With DC motor OLAER LDC optimized for mobile use Olaer is a global player specialising in innovative, efficient system solutions for temperature optimisation and energy storage.
2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7
Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: [email protected] Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).
DS3002 1. General Description This data sheet describes the Modular Power (MP) Electro Hydraulic Power Units, which have been designed to provide an advanced and flexible means of brake control. The MP
PART 2 FORKLIFT HYDRAULIC SYSTEM
PART 2 FORKLIFT HYDRAULIC SYSTEM Chapter 1 Description and Operation Component Locations & Circuit Layouts 1 Hydraulic Pump 11 Control Valve 14 Valve Section Oil Flows 15 Anti-Cavitation Valve 22 Velocity
PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT
PM10 VRIBLE DISPLCEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C L C T L O G PM10 - Variable displacement pump POCLIN HYDRULICS OVERVIEW PM10 is a variable displacement, axial piston pump, with swashplate
Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE 92 500/07.00. for open circuits
RE 92 500/07.00 Replaces: 03.97 Variable isplacement Pump A11VO for open circuits izes 40 260 eries 1 Nominal pressure 350 bar Peak pressure 400 bar A11VO Index Features 1 Ordering Code / tandard Program
3/2-way pneumatic cartridge solenoid valve
3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
SOLENOID VALVES 3-4 WAY
SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight
GoTo Europe Focused Delivery Program. Product Overview Hydraulics
GoTo Europe Focused Delivery Program Product Overview Hydraulics 2 GoTo Europe The products I need when I need them In today s global competition every day counts. Fast response times have become an important
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Series PVP Variable Volume Piston Pumps
Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference
The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.
D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these
Electro-hydraulic pressure switches type DG
Electro-hydraulic pressure switches type DG Pressure p max = 700 bar See also: For electronic pressure switches type DG 5 E see D 5440 E Analogous pressure transducer type DT 1 see D 5440 T Analogous pressure
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
PUMP AND MOTOR DIVISION
INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.
Vickers Pressure Relief Pressure Relief and Sequence Valves CG2V-6/8, 1 Series; CG5V-6/8, 2 Series Typical Section CG2V-6*W-1 relief valve Basic Characteristics Maximum pressure.......... 35 bar (5 psi)
Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.
TXV - Presentation pumps with Load Sensing control variable displacement piston pumps ADVANTAGES pumps are variable displacement with pressure-flow control called Load Sensing. They self-regulate to give
Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits
Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
Check Valves Valve locator
Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()
Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation
Industrial Filters Accumulators Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400 Filters for inline installation for continuous operation With integrated pressure equalisation valve Optimised flow
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS
VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS CEMB SPA Via Risorgimento, 9 Mandello del Lario (Lc), Italy [email protected] www.cemb.com INSTRUMENT FOR MONITORING VIBRATIONS OF FANS INSTALLED IN ROAD
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general