Smartec S CLD134. Technical Information
|
|
|
- Ross Sullivan
- 9 years ago
- Views:
Transcription
1 Technical Information Smartec S CLD134 Hygienic measuring system for conductivity and concentration for applications in the food, beverage and pharmaceutical industries as well as in biotechnology 6 8 Application The inductive conductivity measuring system is specifically intended for use in hygienic applications in the food, beverage and pharmaceutical industries and in biotechnology. Thanks to its food-grade virgin PEEK body, its jointless and creviceless design and its hygienic certificates, it meets the extremely exacting demands of these industries. Compact versions and separate versions are available. The CLD134 is especially suitable for the following applications: Phase separation of product/water and product/product mixtures in pipe systems Control of CIP (cleaning in place) processes in the return channel Concentration control in remaking of CIP cleaning agents Product monitoring in pipe systems, bottling plants, quality assurance Leakage monitoring in the following industries Dairies Breweries Beverages (water, juices, soft drinks) Pharmaceuticals and biotechnology R Your benefits Unique hygienic design, thus no risk of recontamination With all hygienic certificates required in hygienic applications Transmitter housing made of stainless steel Durable thanks to encapsulated, jointless design Fast measurement with temperature response time t 90 under 26 s enables safe and efficient phase separations Various operating possibilities: Keys HART hand-held terminal PROFIBUS PA/DP PC with software FieldCare (with FDT/DTM technology) Standard version extendable by function extension with remote parameter set switching (measuring range switching) Standard Number With quality certificate TI401C/07/en/
2 Function and system design Measuring principle Inductive conductivity measurement A generator (1) generates an alternating magnetic field in the primary coil (2) which induces a current in the medium (3). The strength of the induced current depends on the conductivity and thus the ion concentration of the medium. The current flow in the medium generates another magnetic field in the secondary coil (4). The resulting current induced in the coil is measured by the receiver (5) and processed to determine the conductivity. 1 5 Inductive conductivity measurement 1 Generator 2 Primary coil 3 Current flow in the medium 4 Secondary coil 5 Receiver 2 4 Benefits of inductive conductivity measurement No electrodes, therefore no polarisation Accurate measurement in media or solutions with a high soiling degree and a tendency to deposition Complete galvanic separation of measurement and medium 3 a Important properties of Smartec S CLD134 Hygiene The injection-molded sensor is made of highly chemically, mechanically and thermally resistant PEEK. It does not have joints or crevices and is therefore hygienically safe. The exclusive use of virgin PEEK as material in contact with medium guarantees highest biological safety for the food, beverage and pharmaceutical areas. The sensor has been designed according to the effective guidelines of ASME BPE (The American Society of Mechanical Engineers - Bioprocessing Equipment). Certified hygiene The sensor has all necessary listings and approvals for hygienic areas, such as exclusive use of FDA-listed materials for surfaces in contact with medium and certification from 3-A. The sensor CLS54 has been certified by EHEDG (European Hygienic Engineering and Design Group) regarding in-place cleanability. A certificate on the biological reactivity test according to USP part <87> and <88> class VI including lot tracing back to compounding is available as option. Process connections The sensor is available with all process connections commonly used in hygienic applications. The most common connections are available as standard. Further process connections can be ordered as special versions. Process temperature, process pressure The use of special components and materials makes the sensor suitable for continuous exposure to temperatures of +125 C (275 F). Short-time (max. 60 min.), it may be exposed to +150 C (300 F) for sterilisation. The sensor is pressure-resistant up to 12 bar (174 psi) up to 90 C (194 F). At higher temperatures, its pressure resistance is always higher than the respective steam pressure. The sensor is suitable for underpressure applications. Temperature measurement The sensor has an integrated temperature sensor with a temperature response time t 90 < 26 s. This enables economically efficient phase separations at varying and quickly changing process temperatures. The temperature sensor is embedded into the PEEK body eliminating the need for seals which ensures a long service life. Temperature compensation Smartec S CLD134 offers the following types of temperature compensation: Linear compensation with freely selectable temperature coefficient α Compensation according to IEC for NaCl Compensation with freely programmable coefficient table with 10 elements maximum 2 Endress+Hauser
3 ENDRESS+HAUSER SMARTEC S CAL ALARM Smartec S CLD134 Concentration measurement The transmitter can be switched from conductivity operating mode to concentration operating mode. The concentration operating mode provides one freely programmable as well as various predefined concentration curves, especially for common CIP solutions. This enables a direct display of the concentration in %. Remote parameter set switching Smartec S CLD134 can be ordered with remote parameter set switching (measuring range switching, MRS) enabling you to cover a wide measuring range to adjust temperature compensation when changing the product to switch between concentration curves. Models The measuring system Smartec S CLD134 is available as: compact version for simple installation separate version (sensor and transmitter are connected via cable) Furthermore the transmitter can be ordered separately without sensor. Measuring system A complete measuring system comprises: the Smartec S CLD134 transmitter (separate version) the CLS54 conductivity sensor with integrated temperature sensor and fixed cable or the CLD134 compact version with integrated CLS54 conductivity sensor Optional for the separate version: CLK5 extension cable, VBM junction box, mounting kit for pipe mounting B + E A C Complete measuring systems Smartec S CLD134 as separate transmitter and compact version A CLS54 conductivity sensor B Smartec S CLD134 transmitter C Smartec S CLD134 compact version with integrated CLS54 a Endress+Hauser 3
4 Input Measured variables Measuring range Conductivity Concentration Temperature Conductivity: recommended range: 100 μs/cm to 2000 ms/cm (uncompensated) Concentration: NaOH: 0 to 15 % HNO 3 : 0 to 25 % H 2 SO 4 : 0 to 30 % H 3 PO 4 : 0 to 15 % User 1 (to 4): (4 tables available in versions with remote parameter set switching) Temperature: 35 to +250 C (-31 to +482 F) Temperature measurement Pt 1000 switchable to Pt 100 Sensor cable max. cable length 55 m ( ft) with CLK5 cable (separate version) Binary inputs 1 and 2 Voltage: Current consumption: 10 to 50 V DC max. 10 ma at 50 V Output Output signal Conductivity, concentration: Temperature (optional second current output) 0 / 4 to 20 ma, galvanically isolated Signal on alarm Load 2.4 ma or 22 ma error current max. 500 Ω Output range Conductivity: Temperature: adjustable adjustable Signal resolution Separation voltage max. 700 digits/ma max. 350 V RMS / 500 V DC Minimum distance of output signal Conductivity: Measured value 0 to μs/cm: Measured value 20 to μs/cm: Measured value 200 to 1999 μs/cm: Measured value 0 to ms/cm: Measured value 20 to 200 ms/cm: Measured value 200 to 2000 ms/cm: Concentration: Temperature: 2 μs/cm 20 μs/cm 200 μs/cm 2 ms/cm 20 ms/cm 200 ms/cm no minimum distance 15 C (27 F) Overvoltage protection acc. to EN :1995 Auxiliary voltage output Output voltage: Output current: 15 V ± 0.6 V max. 10 ma 4 Endress+Hauser
5 Contact outputs Switching current with ohmic load (cos ϕ = 1): Switching current with inductive load (cos ϕ = 0.4): Switching voltage: Switching power with ohmic load (cos ϕ = 1): Switching power with inductive load (cos ϕ = 0.4): max. 2 A max. 2 A max. 250 V AC, 30 V DC max. 500 VA AC, 60 W DC max. 500 VA AC Limit contactor Pickup / dropout delay: (versions with remote parameter set switching only) 0 to 2000 s Alarm Function (switchable): Alarm delay: steady / fleeting contact 0 to 2000 s (min) Electrical connection Power supply A ma Lf F B ma optional S G C V D V H E V ~ ~ I PE Electrical connection of CLD134 A Signal output 1 conductivity B Signal output 2 temperature C Auxiliary voltage output D Binary input 2 (MRS 1+2) E Binary input 1 (hold / MRS 3+4) F G H I MRS: a Conductivity sensor Temperature sensor Alarm (contact position: no current) Power supply Remote parameter set switching (measuring range switching) Endress+Hauser 5
6 Sensor connection The conductivity sensor of the separate version is connected using the shielded multi-core fixed cable. Use the junction box VBM and the CLK5 extension cable (see Accessories) to extend the cable length. S GN WH YE BU RD RD BU RD WH CLK5 J Electrical connection of CLS54 a Supply voltage Depending on ordered version: 100 / 115 / 230 V AC +10 / -15 %, 48 to 62 Hz 24 V AC/DC +20 / -15 % Cable entries A B Terminal assignments of cable glands on Smartec S CLD134 A Separate version B Compact version Plug, analog output, binary input Cable gland for alarm contact Cable gland for power supply Housing ground Pressure comp. element PCE (Goretex filter) Cable gland for sensor connection, M16x Plug, analog output, binary input Cable gland for alarm contact Cable gland for power supply Housing ground Pressure comp. element PCE (Goretex filter) a Power consumption Mains fuse max. 7.5 VA Fine-wire fuse, medium time lag, 250 V / 3.15 A 6 Endress+Hauser
7 Performance characteristics Measured value resolution Temperature: 0.1 C (0.18 F) Temperature response time t 90 26s Measured error of the sensor a Conductivity ± (0.5 % of measured value + 10 μs/cm) after calibration (plus inaccuracy of the conductivity of the calibration solution) Temperature: Pt 1000 class A acc. to IEC 751 Measured error of the transmitter a Conductivity: Display: Conductivity signal output: Temperature Display: Temperature signal output: max. 0.5 % of measured value ± 4 digits max % of current output range max. 0.6 % of measuring range max % of current output range Repeatability a Conductivity: max. 0.2% of measured value ± 2 digits Cell constant 6.3 cm -1 Measuring frequency (oscillator) 2 khz Temperature compensation Reference temperature Range: Compensation types: Minimum distance for table: 25 C (77 F) 10 to +150 C (14 to 302 F) none linear with freely selectable temperature coefficient α one freely programmable coefficient table (four tables available in versions with remote parameter set switching) NaCl acc. to IEC K Temperature offset adjustable, ± 5 C (9 F), for temperature display adjustment a) acc. to IEC part 1, at nominal operating conditions Endress+Hauser 7
8 Installation Installation instructions! Note! For use in hygienic applications only use materials that comply with 3-A standards and the FDA requirements. The cleanability of a sensor also depends on the way of installation. To install the sensor in a pipe system use the appropriate and EHEDG certified flow assembly for the respective process connection. The sensor has to be immersed completely into the media. Avoid bubbles in the area of the sensor. A Installation positions of conductivity sensors A Installation position is not useable for hygienic applications. a The media should flow through the bore of the sensor (see indicator arrow of the sensor body). The symmetrical measuring channel allows a flow in both directions. In narrow installation conditions, the ion flow in the medium is affected by the pipe walls. This effect is compensated by the so-called installation factor. The installation factor can be entered in the transmitter or the cell constant can be corrected by multiplication with the installation factor to ensure correct measurement. The value of the installation factor depends on the diameter and the conductivity of the pipe as well as the sensor s distance from the wall. If the distance from the wall is sufficient (a > 15 mm, from DN 65), it is not necessary to consider the installation factor (f = 1.00). If the distance from the wall is smaller, the installation factor increases in case of electrically insulating pipes (f > 1) and decreases in case of electrically conductive pipes (f < 1). The installation factor can be measured using calibration solutions or it can be approximately determined from the diagram below. Installation of CLS54 a Wall distance a a Endress+Hauser
9 f a [mm] Dependance of installation factor f on wall distance a 1 Conductive pipe 2 Insulating pipe a [inch] a Air set To compensate residual coupling in the cable and between the two sensor coils, you must perform a zero calibration in air ("air set") before installing the sensor. Endress+Hauser 9
10 Mounting CLD134 separate version 142 / / 8.86 Ø 7 / / / / / 3.74 CLD134 wall mounting mm /inch a ! Note! Wall mounting is not recommended for hygienic sensitive areas. 109 / 4.29 Ø max. 60 / Ø max / / 3.74 mm / inch CLD134 mounting on pipes (Ø 60 mm / 2.36") using the pipe mounting kit (see Accessories) a ! Note! For use in hygienic sensitive areas, shorten the threads as much as possible. 10 Endress+Hauser
11 Mounting CLD134 compact version 225/ / / /5.59 *** Ø9/ / / /3.74 mm/inch 28.5/1.12 Dimensions CLD134 compact version *** depending on ordered process connection a ! Note! The symmetrical measuring channel allows a flow in both directions. The housing can be rotated against the sensor to allow comfortable viewing of the display in any mounting position. Endress+Hauser 11
12 Ambient temperature Environment Compact version or electronics box: Sensor separately: 0 to +55 C (32 to 131 F) -20 to +60 C (-4 to +140 F) Ambient temperature limits Storage temperature 10 to +70 C (14 to 158 F) (separate version and separate transmitter) 10 to +55 C (14 to 131 F) (compact version) See figure "Permissible temperature ranges of Smartec S CLD134". 25 to +70 C (-13 to 158 F) Electromagnetic compatibility Interference emission and interference resistance acc. to EN 61326: 1997 / A1: 1998 Ingress protection IP 67 Relative humidity Vibration resistance acc. to IEC and IEC to 95%, non-condensing Oscillation frequency: 10 to 500 Hz Deflection (peak value): 0.15 mm (0.01") Acceleration (peak value): 19.6 m/s 2 (64.3 ft/s 2 ) Impact resistance Display window: 9 J Process Process temperature Sterilisation Process pressure CLS54 sensor with separate version: max. 125 C (257 F) at 70 C (158 F) ambient temperature Compact version: max. 125 C (257 F) at 35 C (95 F) ambient temperature max. 55 C (131 F) at 55 C ambient temperature CLS54 sensor with separate version: 150 C (302 F) at 70 C (158 F) ambient temperature, 5 bar (72.5 psi), max. 60 min Compact version: 150 C (302 F) at 35 C (95 F) ambient temperature, 5 bar (72.5 psi), max. 60 min max. 12 bar (174 psi) up to 90 C (194 F) underpressure down to 0.1 bar (1.45 psi) absolute Permissible temperature ranges of Smartec S CLD134 Ambient temperature [ F] [ C] A B C Medium temperature Permissible temperature ranges of Smartec S CLD134 A CLS54 sensor with separate version B Compact version C Short-term for sterilisation (< 60 min) [ C] [ F] a en 12 Endress+Hauser
13 Pressure-temperature load curve of CLS54 sensor [psi] [bar] A [ C] Permissible pressure and temperature ranges of CLS54 sensor A Short-term for sterilisation (< 60 min) [ F] a Mechanical construction Dimensions Separate transmitter with mounting plate: L x W x D: 225 x 142 x 109 mm (8.86 x 5.59 x 4.29 ") Compact transmitter: MV5, CS1, AA5, SMS versions: L x W x D: 225 x 142 x 255 mm (8.86 x 5,59 x ") VA4, BC5 versions: L x W x D: 225 x 142 x 213 mm (8.86 x 5.59 x 8.39 ") Weight Separate version: Transmitter: CLS54 sensor: Compact version with CLS54 sensor: approx. 2.5 kg (5.5 lb.) depending on version 0.3 to 0.5 kg (0.66 to 1.1 lb.) approx. 3 kg (6.6 lb.) Surface roughness R a 0.8 μm (smooth, injection-molded PEEK surface) for the surfaces in contact with medium Materials of the sensor In contact with medium: Not in contact with medium: Virgin PEEK PPS-GF40 Stainless steel (AISI 316L) Screws: (AISI 304) FKM, EPDM (seal) PVDF (cable gland - separate version only) TPE (cable - separate version only) Materials of the transmitter Chemical durability of the sensor Housing: stainless steel Front window: polycarbonate Medium Concentration PEEK Caustic soda NaOH 0 to 15 % 20 to 90 C (68 to 194 F) Nitric acid HNO 3 0 to 25 % 20 to 90 C (68 to 194 F) Phosphoric acid H 3 PO 4 0 to 15 % 20 to 80 C (68 to 176 F) Sulphuric acid H 2 SO 4 0 to 30 % 20 C (68 F) Peracetic acid H 3 C-CO-OOH 0.2 % 20 C (68 F) No responsibility is taken for the correctness of this information. Endress+Hauser 13
14 Process connections Dairy pipe fitting DIN 11851, DN 50 a) Aseptic fitting DIN form A, for pipe according to DIN 11850, DN 50 Clamp ISO 2852 (also for TriClamp, DIN 32676), 2" b) SMS 2" c) Varivent N DN NEUMO BioControl D50 Additional process connections are available on request. a) Dairy pipe fitting DIN is generally not considered hygienic. With the adapter SKS Siersma, it meets the 3-A standards requirements. b) Clamp connection is only hygienic in connection with Hyjoin PEEK/stainless steel ring from Hyjoin Ltd., UK, and Kalrez seal from Dupont. c) Process connection is not considered hygienic according to the requirements of EHEDG. Process connections of CLD134 compact version (short) A NEUMO BioControl D50 B Varivent N DN a Endress+Hauser
15 Process connection of CLD134 compact version (long) A Dairy pipe fitting DIN 11851, DN 50 (union nut is included, but not shown) B SMS 2" (union nut is included, but not shown) C Clamp ISO 2852, 2" D Aseptic fitting DIN form A, for pipe according to DIN 11850, DN 50 a Process connections CLS54 (short) A NEUMO BioControl D50 B Varivent N DN a Endress+Hauser 15
16 Process connections CLS54 (long) A Dairy pipe fitting DIN 11851, DN50 (union nut is included, but not shown) B SMS 2" (union nut is included, but not shown) C Clamp ISO 2852, 2" D Aseptic fitting DIN form A, for pipe according to DIN 11850, DN 50 a Endress+Hauser
17 Human interface Display and operating elements ms/cm O ma ENDRESS+HAUSER SMARTEC S CAL + ALARM 4 2 E 3 Display and keys of CLD134 1 LC display showing measured values and configuration data 2 Four operating keys for calibration and instrument configuration 3 Field for user labeling 4 LED indicator for alarm function a Operation You have the following options of operating Smartec S CLD134: Local operation via operating keys The four keys are located underneath the housing cover. For operation, open the housing cover by removing the four screws. Via HART interface HART hand-held terminal PC with HART modem and the FieldCare software (with FDT/DTM technology) Via PROFIBUS PA/DP using a PC with a corresponding interface and the FieldCare software (with FDT/DTM technology) or via programmable logical controller (PLC) Endress+Hauser 17
18 Calibration and configuration functions All calibration and configuration functions are arranged in a logical menu structure. The individual parameters can only be modified after entering the access code. The current position within the menu structure is displayed. Overview of the Smartec S CLD134 menu, showing all options that can be installed * Menus not available in standard version C07-CLD132xx en-001.eps 18 Endress+Hauser
19 Hygienic certificates Product structure! Note! Certificates and approvals FDA All materials in contact with medium are listet at FDA. EHEDG The sensor CLS54 has been certified for in-place cleanability according to EHEDG document 2. The cleanability of a sensor also depends on the way of installation. To install the sensor in a pipe system use the appropriate and EHEDG certified flow assembly for the respective process connection. 3-A Certified according to 3-A Standard ("3-A Sanitary Standards for Sensor and Sensor Fittings and Connections Used on Milk and Milk Products Equipment"). Biological reactivity (USP class VI) (optional) Certificate on biological reactivity tests according to USP (United States Pharmacopeia) part <87> and part <88> class VI with traceability of the materials in contact with medium. Ordering information CLD134- Housing E Transmitter only (without sensor) P Compact version W Separate transmitter, cable length 5 m / ft X Separate transmitter, cable length 10 m / ft S Separate transmitter, cable length 20 m / ft Process connection 000 Not selected (transmitter only) MV5 Dairy fitting DIN 11851, DN 50 a) AA5 Aseptic fitting DIN form A, pipe DIN 11850, DN 50 CS1 Clamp ISO 2852, 2" (long) b) SMS SMS 2" c) VA4 Varivent N DN 40 to 125 BC5 NEUMO BioControl D50 Cable entry 3 Cable gland M 20 x Conduit adapter NPT ½ " Power supply V AC V AC V AC 8 24 V AC / DC Current output / communication AA Current output conductivity, without communication AB Current output conductivity and temperature, without communication HA HART, current output conductivity HB HART, current output conductivity and temperature PE PROFIBUS-PA, no current output PF PROFIBUS-PA, M 12 connector, no current output PP PROFIBUS-DP, no current output Additional features 1 Basic version 2 Remote parameter set switching 3 Biological reactivity tests according to USP <87>, <88> class VI 4 Remote parameter set switching and biological reactivity tests according to USP <87>, <88> class VI complete order code a) Dairy pipe fitting DIN is generally not considered hygienic. With the adapter SKS Siersma, it meets the 3-A standards requirements. b) Clamp connection is only hygienic in connection with Hyjoin PEEK/stainless steel ring from Hyjoin Ltd., UK, and Kalrez seal from Dupont. c) Process connection is not considered hygienic according to the requirements of EHEDG. Endress+Hauser 19
20 Scope of delivery The scope of delivery of the compact version inlcudes: Smartec S CLD134 compact measuring system with integrated sensor Terminal strip set Operating Instructions BA401C/07/en Versions with HART communication only: Operating Instructions Field communication with HART, BA212C/07/en Versions with PROFIBUS interface only: Operating Instructions Field communication with PROFIBUS, BA213C/07/en M12 connector (-******PF* versions only) The scope of delivery of the separate version includes: Smartec S CLD134 transmitter CLS54 inductive sensor with fixed cable Terminal strip set Operating Instructions BA401C/07/en Versions with HART communication only: Operating Instructions Field communication with HART, BA212C/07/en Versions with PROFIBUS interface only: Operating Instructions Field communication with PROFIBUS, BA213C/07/en M12 connector (-******PF* versions only) The scope of delivery of version "transmitter without sensor" includes: Smartec S CLD134 transmitter Terminal strip set Operating Instructions BA401C/07/en Versions with HART communication only: Operating Instructions Field communication with HART, BA212C/07/en Versions with PROFIBUS interface only: Operating Instructions Field communication with PROFIBUS, BA213C/07/en M12 connector (-******PF* versions only) Basic version and function extensions Functions of the basic version Measurement Calibration of cell constant Calibration of residual coupling Calibration of installation factor Read instrument parameters Linear current output Current output simulation Service functions Temperature compensation selectable (e.g. 1 free coefficient table) Concentration measurement selectable (4 defined curves, 1 free table) Relay as alarm contact Options and their functions Second current output for temperature (hardware option) HART communication PROFIBUS communication Remote parameter set switching (software option): Remote switching of max. 4 parameter sets (measuring ranges) Temperature coefficients can be determined Temperature compensation selectable (e.g. 4 free coefficient tables) Concentration measurement selectable (4 defined curves, 4 free tables) Check of measuring system by PCS alarm (live check) Relay can be configured as alarm or limit contact Biological reactivity according to USP <87>, <88> class VI 20 Endress+Hauser
21 Accessories Cable extension CLK5 measuring cable Extension cable for connecting CLS52/54 and transmitter via the VBM junction box, sold by the meter; order no Junction box VBM for extension of measuring cable connection between sensor and instrument, material cast aluminium, ingress protection 65; order no.: ! Note! The desiccant bag must be checked and replaced at regular intervals which depend on ambient conditions in order to prevent inaccurate measurement due to moisture bridges in the measuring line. 10 / 0.39 approx. 136 / / / / / / / 2.17 mm / inch 26.8 / 1.06 a en Desiccant bag with color indicator for VBM junction box; order no Pipe mounting kit Mounting kit for installation of Smartec S CLD132/CLD134 on horizontal or vertical pipes and posts (max. Ø 60 mm (2.36")), material stainless steel ; order no.: C07-CLD132xx eps Mounting kit for installing CLD132/CLD134 separate version on posts or pipes (base plate belongs to the scope of delivery of the transmitter) Endress+Hauser 21
22 Software upgrade Optoscope Calibration solutions Software upgrade Remote parameter set switching (measuring range switching, MRS) and determination of temperature coefficient; order no.: Serial number of instrument must be specified with order. Optoscope Interface between transmitter and PC / laptop for service purposes. The Windows software "Scopeware" required for the PC or laptop is supplied with the Optoscope. The Optoscope is supplied in a sturdy plastic case with all the accessories required. Order no Precision solutions, traceable to SRM (standard reference material) by NIST, for qualified calibration of conductivity measurement systems according to ISO 9000, with temperature table CLY11-B μs/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order no CLY11-C ms/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order no CLY11-D ms/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order no CLY11-E ms/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order no Documentation Smartec S CLD134, Operating Instructions BA401C/07/en Indumax H CLS54, Technical Information TI400C/07/en 22 Endress+Hauser
23 Endress+Hauser 23
24 Instruments International Endress+Hauser Instruments International AG Kaegenstrasse Reinach Switzerland Tel Fax [email protected] TI401C/07/en/ Printed in Germany / FM+SGML 6.0 / DT
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
ph/redox Measurement MyPro CPM 431
Technical Information TI 173C/07/en/06.02 50088309 ph/redox Measurement MyPro CPM 431 Two-wire transmitter for ph and redox with Hart and PROFIBUS-PA communication for use in Ex and non-ex areas Application
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
RTD Temperature Probe for the Food/Pharmaceutical Industry
[email protected] Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules
0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Conductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
Wahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
Liquisys M CCM223/253
Technical Information Liquisys M CCM22/25 Measurement of free chlorine/chlorine dioxide/total chlorine Transmitter for chlorine sensors Application The modular design of the Liquisys M CCM22/25 allows
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
Features. Picture. Specifications
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
SMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
SINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
2.24. Pump Controller 704. Data Sheet
Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with
J TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space
PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm
Electronic pressure measurement Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm WIKA data sheet PE 86.11 Applications Process engineering Pharmaceutical industry
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
DS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Flow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S
Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and
Temperature Switch Thermophant T TTR 31, TTR 35
Technical Information Temperature Switch Thermophant T TTR 3, TTR 35 Temperature switch for the safe measurement, monitoring and control of process temperatures Application Temperature switch for the monitoring,
S300 Series Dust Monitors
S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and
SITRANS F flowmeters SITRANS F M. Transmitter MAG 5000/6000. 4/32 Siemens FI 01 2010. Overview
Overview Design The transmitter is designed as either IP67 NEMA X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP20/NEMA
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
Differential Charge Amplifier
Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Relative and absolute pressure switch type 529
Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Stainless steel process fittings
Page 1/6 Stainless steel process fittings Installation in pipe systems Installation in tanks and vessels Hygienic version FDA conformity of materials Probe length 120 mm 120 mm Availability of various
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
Reaction Torque Sensor
Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and