PRODUCT DATA Observer
|
|
|
- Godfrey McCormick
- 9 years ago
- Views:
Transcription
1 PRODUCT DATA Modular Precision Sound Analyzer 2260 Observer Including BZ 7219 Sound Analysis Software and BZ 7220 Room Acoustics Software 2260 Observer is a state-of-the-art sound level meter and sound analyzer. It's a hand-held instrument capable of doing all the measurements and analyses that are typically used when assessing community noise and noise at the work place Observer complies with the new sound level meter standard IEC as well as the previous IEC standards (60651 and 60804), and the latest ANSI standards. All broadband parameters and statistical values are measured in parallel, so you will never miss a beat: all parameters are there you just choose what you want to examine, now or later. Additionally, and simultaneously, real-time analysis in 1/1- or 1/3-octave bands is carried out. Broadband and spectral data can all be logged to obtain a time history (profile) for later analyses. As an option to these standard facilities, you can add measurements of reverberation time. Using this option, acceptance test of rooms, noise reduction in workplaces and similar tasks are carried out conveniently. Reverberation time can be measured using impulsive noise (e.g., using a starting pistol), or you can use the built-in generator and a sound source Observer can be upgraded to include the full range of advanced applications from the 2260 Investigator range of products, for example sound intensity, two-channel building acoustics, and FFT analysis Observer
2 USES FEATURES Environmental noise assessment Octave or 1/3-octave band analyses Noise monitoring Appraisal of sound reduction efforts Gathering field data for further analyses Research and development Reveration time measurement (BZ 7220 only) IEC and ANSI Type 1 /Class 1 sound level meter 6.3 Hz 20 khz frequency range in 1/3-octave band analysis On-line annotation and data exclusion Control of sound recording on a PC Remote operation via modem link Measures reverberation time with impulse or interrupted noise excitation (BZ 7220 only) Displays reverberation time and decay curves (BZ 7220 only) Calculates broadband average reverberation time (BZ 7220 only) Introduction Fig. 1 Typical 2260 spectrum display using BZ 7219 software 2260 Observer is based on a versatile hand-held analyzer platform. As standard, the analyzer is delivered with software that makes the instrument very well suited for most of the tasks relevant to assessment of environmental noise. This software is also useful in any other contexts where broadband level measurements or 1/1- or 1/3-octave band analyses of sound is needed. The frequency range covered in 1/3-octaves is 6.3 Hz to 20 khz Observer can be extended to allow measurements of reverberation time in 1/1- or 1/3-octaves. Additionally, as described later, it is even possible to upgrade the instrument to cover advanced two-channel applications such as intensity measurements and building acoustics. Making Measurements Basically, making measurements is a simple matter of starting, pausing, stopping and storing. However, with the plethora of parameters and setup options offered by 2260 Observer, you will enjoy the ability to define setups and store them under a name of your choice. This is useful for recurring tasks as well as special assignments Observer also lets you define your own displays, that is, you define which of the many parameters you want to see on-screen and which you will only need for later analyses. Whenever a measurement is stored, all parameters are stored, except those you have explicitly deselected. 2
3 Many measurements are made with an operator on-site. Documenting measurement conditions and acquiring representative samples, requires an operator in most cases, as does the visual identification of sound sources. With 2260 Observer you can make on-line annotations of your measurement by attaching named markers to a profile. Furthermore, the actual sound can be recorded on a PC for identification and attached to the profile, when the profile is transferred to a PC. Markers and Sound Recording Fig Observer screen showing three of the markers Markers are set on the fly. There are four markers that can be named, for example to identify sound sources, and an additional exclude marker to mark unwanted sound and exclude it from later processing. Markers can be selected in any order and for any duration. You can set all the markers to finish automatically after a predefined time or set to continue until you stop each one. The markers are saved with the measurement and are transferred with the measurement to post-processing software on a PC. If sound recording is activated, using 7820 Evaluator, 7825 Protector or 7815 Noise Explorer, a.wav file can be recorded on the PCs hard disk at the same time as a marker is set. The recording is controlled from 2260 Observer. When, at a later stage, the measurement is transferred to the PC, the recordings are merged with the profile. The sound recordings are then marked in the profile display and can be replayed. You use the cursor position in the profile display to decide which part of the recording you want to hear. See Fig. 8. Remote Access Fig. 3 Outdoor Gear Type 3592 Noise monitoring in out-of-the-way places no longer needs to be a problem. Outdoor Gear Type 3592 offers security and weather protection for 2260 Observer. Safe and dry in its robust, heat reflecting, bright yellow case, the analyzer will operate unattended for more than 3 days. For longer periods, the battery can be changed without interrupting measurements. You can also save yourself a site visit by using the modem dial-up facility to collect your results. The system consists of a weatherproof case, outdoor microphone kit, microphone extension cable, microphone tripod or mast, sealed lead-acid battery, and battery charger. The Outdoor Gear Type 3592 system is modular, allowing you to assemble a monitoring system that meets your exact requirements. Evaluator Type 7820 software on your PC controls the communication process and allows measurement files to be downloaded directly to your PC's hard disk, thus freeing space for more results. The modem 3
4 interface is standard RS-232. You can connect either a land-line modem or a mobile phone with a digital interface. The Type 3592 case has a space for the modem/mobile phone, and is transparent to radio waves. Measurement Parameters Fig. 4 Screen showing real-time simultaneous display of broadband parameters and Elapsed Time Fig. 5 Statistics screen showing a level distribution curve. The cursor is at the 69 db to 70 db interval, showing there are 1.9% of the samples in the interval However many sound parameters (discrete, spectral and statistical) you select to measure with 2260 Observer, they will all be measured concurrently. Serial measurements, which are expensive and time consuming, are not necessary. While viewing a spectrum, you can switch over to see how any of the other parameters are developing, for example, the current values of L N or L Ceq L Aeq. Such analysis techniques are advantageous when the sound source is complex and you need on-the-spot tonal information, for example, when choosing hearing protection aids. When you ve made your measurements, you can store the final results in a file to view or analyse later. Measurements can be started manually or automatically. The automatic mode uses Observer s nine timers, clock and calendar. You simply select how often the analyzer is to be woken up to make and store the required measurement data and the analyzer does the rest. You can see from the specifications that 2260 Observer can measure an impressive array of parameters based on various combinations of time and frequency weightings, filtering, and detection of peaks, etc. During measurements, the A-weighted, and C- or L-weighted sound signals are sampled and processed by the real-time DSP. The DSP continuously calculates the current values for the whole array of selected sound parameters, which you can display immediately and store later when the measurement is completed. Reverberation Time Measurements Measurements of reverberation time are often used for noise reduction in the workplace and determination of room corrections Observer s optional reverberation time module BZ 7220 is an ideal solution for these applications. Fig. 6 Decay curve as shown on 2260 Observer s display The reverberation time can be measured using the impulsive noise method. In this case you need only to carry the 2260 Observer and a starting pistol to, for example, a factory hall. Impulse decays are computed in all frequency bands simultaneously by backwards integration (Schroeder method). Alternatively, the built-in generator can be used in combination with a power amplifier and a loudspeaker source, thus allowing measure- 4
5 ments using the interrupted noise method. In conditions of high background noise, serial measurements are supported. A broadband average reverberation time can be computed from the bands you select and viewed on-screen. Post-processing Software Fig. 7 Spectrum graphs from different measurement files displayed by Noise Explorer Type 7815 With its 32 MB internal memory, 2260 Observer can store a large amount of data. To make it easy and efficient for you to examine the results of the measurements, and to make further analyses such as rating level or exposure calculations, Brüel & Kjær offers a number of Windows -based software application packages. Each of the software packages is described in a separate product data sheet. Noise Explorer Type 7815 Noise Explorer is software for displaying and reporting noise measurements made with a number of Brüel & Kjærhand-held instruments, including 2260 Observer. As well as displaying the data as graphs, spectra or statistics curves, Noise Explorer has a range of export features allowing you to export your measurement data to other programs or send to a printer. Noise Explorer has the facility to let the operator record and replay sound events to aid post-processing. Evaluator Type 7820 Evaluator has similar display options to Noise Explorer. It is specifically designed to calculate Rating Levels (a single figure evaluation of environmental noise normally based on the L Aeq with various penalties) according to the standards and legislation you follow. Using Evaluator with measurement data produced by 2260 Observer, you can quickly arrive at Rating Level figures. For noise reduction analysis, noise levels can be edited to give you on-screen indications of what if situations. The facility to record sound events is also available with this software. 5
6 Fig. 8 Evaluator Type 7820 calculating the rating level Fig. 9 Protector Type 7825 can show the noise exposure from an entire plant Protector Type 7825 Protector is software for post-processing, simulating and archiving noise exposure data. Protector works with the family of Brüel & Kjær dose meters, sound level meters and analyzers including 2260 Observer. Protector allows you to quickly download sample noise profiles for specific locations or persons, which Protector can then use to calculate noise exposure for people or positions under investigation. Protector calculates noise exposure according to ISO For situations where only work point noise measurements are available, and workers move about, Protector can combine workpoint measurements with a profile of the persons movements, to simulate their personal noise exposure. Qualifier Type 7830/31 Qualifier Type 7831 is for post-processing of reverberation time data. When data are transferred from 2260 Observer you see the same results as in the instrument, including selected standard and the setup parameters. Reverberation times can be modified by drawing a new slope line across a displayed decay curve. Reverberation-time measurements can be averaged in two ways: Averaging of reverberation times (T20 and T30) or Averaging of decay curves (multispectra), also called ensemble averaging. This method produces an average decay curve (multispectrum) for each frequency band 6
7 Fig. 10 Qualifier Type 7830 documenting reverberation time measurements Upgrade Path 2260 Observer always comes with Sound Analysis Software BZ 7219 pre-installed. The Room Acoustics Software BZ 7220 is an option that can be installed on the Observer at a later time by the user. In addition, 2260 Observer can be upgraded to a 2260 Investigator (described in separate data sheets). Investigator is a 2-channel platform for which a range of additional applications is available: Enhanced Sound Analysis, including event detection and event logging (100 ms intervals) as well 10 ms logging of L AF Building Acoustics, including measurements of airborne and impact sound insulation in one or two channels Sound Intensity measurements for sound power measurements and noise source location Narrow-band analyses (Fast Fourier Transform (FFT)) of sound and vibration with built-in pure tone detection according to several standards Noise Profile Software for logging noise parameters within a 110 db dynamic range 7
8 Compliance with Standards, CE-mark indicates compliance with: EMC Directive and Low Voltage Directive. C-Tick mark indicates compliance with the EMC requirements of Australia and New Zealand Safety EMC Emission EMC Immunity Temperature Humidity Mechanical EN and IEC : Safety requirements for electrical equipment for measurement, control and laboratory use. UL : Standard for Safety Electrical measuring and test equipment EN : Generic emission standard. Part 1: Residential, commercial and light industry. CISPR 22: Radio disturbance characteristics of information technology equipment. Class B Limits. FCC Class B Limits. Note: the above is only guaranteed using accessories listed in this Product Data Sheet. EN : Residential, commercial and light industry. RF immunity implies that sound level indications of 40 db or greater will be affected by no more than ±0.5dB. EN (1995): Industrial environment. RF immunity implies that sound level indications of 55 db or greater will be affected by no more than ±0.5dB. Note: the above is only guaranteed using accessories listed in this Product Data Sheet. IEC & IEC : Environmental Testing. Cold and Dry Heat. Operating Temperature: <0.5 db 10 C to +50 C (+14 F to +122 F) Storage Temperature: 25 C to +70 C ( 13 F to +158 F) IEC : Damp Heat: 90% RH (non-condensing at 40 C (104 F)) Effect of Humidity: <0.5 db for 30% < RH < 90% (at 40 C (104 F) and 1 khz) Non-operating: IEC : Vibration: 0.3 mm, 20 m/s 2, Hz, IEC : Shock: 1000 m/s 2 IEC : Bump: 1000 bumps at 250 m/s 2 Calibration Initial factory calibration traceable in conjunction with ISO 9001 Specifications Type 2260 Observer with BZ 7219 Software Specifications apply to 2260 Observer fitted with the supplied microphone and input stage, and running BZ7219 software STANDARDS Conforms with the following: IEC (1979) Type 1 plus Amendments 1 and 2 IEC (2000) Type 1 IEC (Draft March 2001) Class 1 IEC (1995) Octave Bands and 1/3-octave Bands Class 0 ANSI S Type 1 plus ANSI S1.4A 1985 Amendment ANSI S Type 1 ANSI S Octave Bands and 1/3-octave Bands, Order 3, Type 0-C, Optional Range SUPPLIED MICROPHONE Type 4189: Prepolarized Free-field 1/2 Microphone Nominal Sensitivity: 26dB±1.5dB re 1V/Pa Capacitance: 14 pf (at 250 Hz) INPUT STAGE ZC 0026 Extension Cables: Up to 100 m between the input stage and the Type 2260 can be driven by the input stage CALIBRATION Initial calibration is stored for comparison with later calibrations. Acoustic: Using Sound Level Calibrator Type 4231, Multifunction Acoustic Calibrator Type 4226 or Pistonphone Type 4228 Electrical (internal): Uses internally generated electrical signal combined with a keyed-in value of microphone sensitivity MEASURING RANGES Linear Operating Range: 80 db adjustable to give full-scale readings from 80 db to 130 db in 10 db steps Max. Peak Level: 3 db above full scale reading Upper Limit (RMS) for Crest Factor = 10: 17 db below full scale reading Passive Attenuation: Microphone attenuator ZF 0023 (included) effectively increases all full-scale readings by 20 db OCTAVE and 1/3-OCTAVE BAND FILTERS Octave Band Centre Frequencies: 8 Hz to 16 khz 1/3-octave Band Centre Frequencies: 6.3 Hz to 20 khz DETECTORS Overload detector which monitors the overload outputs of all the frequency weighted channels Parallel detectors on every measurement: A-weighted broadband detector channel with three exponential time weightings (Fast, Slow, Impulse), one linearly averaging detector and one peak detector C- or L-weighted (switchable) as above for A-weighted Octave band filters, pre-weighted either A-, C- or L-, each with a detector channel containing one linearly averaging detector and one exponentially averaging detector switchable between Slow or Fast INHERENT NOISE LEVEL (Combination of electrical noise and microphone thermal noise at 20 C). Typical values with supplied microphone of nominal sensitivity: Weighting Electrical Noise (2260) Thermal Noise (4189) Combined Noise A 12.3 db 14.6 db 16.6 db C 14.0 db 15.3 db 17.7 db Lin. 5Hz 20kHz 19.2dB 15.3dB 20.7dB Lin. 3 Hz 20 khz 26.4 db 15.3 db 26.7 db CORRECTION FILTERS Sound Incidence: Built-in filters for correction of frontal/random sound incidence 8
9 Windscreens: Built-in filters for correcting the influence of Protective Cover UA 1236, Windscreen UA 0459 (65 mm) and UA 0237 (90 mm) MEASUREMENTS V = frequency weightings C or L X = frequency weightings A, C or L Y = time weightings S, F N = number For Display and Storage (Broadband) Start Date Start Time Measurem. No. Stop Date Stop Time Overload % Elapsed Time No. of Pauses Underrange % Level Distribution Cumulative Distribution L Apk(MaxP) L Vpk(MaxP) #Peaks A>L # PeaksV>L L AE(ASEL) L Aeq L Veq L AIm L VIm L Veq-LAeq L AIm- L Aeq L ASTm3 L AFTm3 L AITm3 L VSTm3 L VFTm3 L VITm3 L ASTm5 L AFTm5 L AITm5 L VSTm5 L VFTm5 L VITm5 L ASMax L AFMax L AIMax L ASMin L AFMin L AIMin L VSMax L VFMax L VIMax L VSMin L VFMin L VIMin L XYN1 L XYN2 L XYN3 L XYN4 L XYN5 L AEP,d For Display and Storage (Spectrum) L Xeq L XYMax L XYMin Only for Display as Numbers or Bargraphs (Broadband) L AS(SPL) L AF(SPL) L AI(SPL) L VS(SPL) L VF(SPL) L VI(SPL) L AS(Inst) L AF(Inst) L AI(Inst) L VS(Inst) L VF(Inst) L VI(Inst) L AST3 L AFT3 L AIT3 L VST3 L VFT3 L VIT3 L AST5 L AFT5 L AIT5 L VST5 L VFT5 L VIT5 L Apk(Peak) L Vpk(Peak) For Storage During Logging (Broadband) Nothing or All parameters or All parameters without statistics or 6 Major Parameters: L Aeq L Cpk(MaxP) (or L Lpk(MaxP) if L is selected) L AFMax L Ceq (or L Leq if L is selected) L AFMin L AIm For Storage during Logging (Spectrum) Nothing or All Parameters or L eq (pre-weighting A,C, or L as selected) Only for Display as Numbers or Spectra (Spectrum Bands) L XY(SPL) L XY(Inst) The Broadband Level Distribution, Cumulative Distribution and Statistics LXYN1-5 are based upon sampling L XY(Inst) every 10 ms into 0.2 db wide classes over 80 db MEASUREMENT CONTROL Measurement Types: Manual manually controlled single measurement Automatic with preset measurement time Logging a single measurement with a selectable duration of 1 s to 100 days in 1 s steps. Logging duration divided into logging intervals of 1 s to 100 hours in 1 s steps Elapsed Time: When not in Logging mode, elapsed time resets/ starts and pauses/continues according to the respective command. In Logging Mode, elapsed time continues in real-time, regardless of pauses in a measurement GPS DATA A position can be attached to a measurement job by inputting data from a GPS (Global Positioning System) receiver via the Serial Interface Receiver Standards Supported: NMEA 0183 ver. 2.20, optional corrected to Differential GPS using RTCM 104 ver. 2.1 Baud Rate: 4800 bps TIMERS Up to nine independent timers can be specified. Each timer wakes-up the analyzer at a specified date and time and initiates a measurement in accordance with predefined setups. Timed measurement can be repeated up to 999 times. Timers from different software applications can be mixed BACK ERASE Up to the last 15 s of data can be erased, except when logging MARKERS One data exclusion marker and four user-definable markers for on-line annotation of sound categories heard during the measurement (logging only) CONTROL OF SOUND RECORDING Sound recording (.wav files on a PC using Type 7815, 7820 or 7825) can be controlled from 2260 via RS-232 interface and Aux output connected to the sound card on the PC MEASUREMENT DISPLAYS SLM: One main and five secondary parameters can be specified plus one analog bar with zoom facilities Cumulative Distribution: Broadband plus one analogue bar Level Distribution: Broadband. Class width can be specified. Also with one analogue bar. Zoom facilities provided Profile: The last 15 s of L AF(Inst) plus one analog bar for manual measurement or the last 60 s with markers for logging measurements Spectrum: Spectrum + two broadband bars plus one peak bar. Zoom facilities provided. The four graphical displays also have cursor read-out facilities STORAGE SYSTEM Internal Hard Disk: Up to 32 MB for application software, user setups and data External Memory Card for store/recall of measurement data (SRAM or SanDisk ATA Flash Cards) MS-DOS compatible file system (from ver. 3.3) SERIAL PRINTER/OUTPUT Set-ups and measurement data can be printed on an IBM Proprinter (or compatible), Portable Printer Type 2322 or The formats can be screen dumps, tables or graphs Measurement data can be output in spreadsheet format or as a binary file for post-processing on a PC HELP AND USER LANGUAGES Concise context-sensitive help throughout in English, German, French, Italian, Spanish or Czech CLOCK Back-up battery powered clock. Accuracy better than 1 minute per month INPUT STAGE CONNECTION Connector: 10-pin LEMO AUX OUTPUTS (2 independent) Can be set to: L AF(Inst.) : 0 to 4 V DC signal updated every 100 ms Reference: 4 V square-wave for output calibration Meas. Status for triggering external devices Signal from amplified frequency weighted signal (A, C/L) 9
10 AC INPUTS/OUTPUTS (2) As Output: Buffered, unweighted microphone signal Output Impedance: Maximum Load: 47 k 200 pf (short-circuit protected) As Input: Alternative to microphone input Connector: 3-pin LEMO (balanced input) SERIAL INPUT/OUTPUT Conforms to EIA ITIA 574 (RS 232), coupled as data terminal equipment (DTE) Connector: 9-pin D-type male Baud Rates: 1200, 2400, 4800, 9600, 19200, 38400, Word Length: 8 bits, no parity or stop bits Handshake: None, XON/XOFF, RTS/CTS SETTLING TIME From Power On: approximately 35 s BATTERIES Type: 6 LR14/C-size 1.5 V alkaline Lifetime (at 20 C): 5 to 9 hours continuous operation EXTERNAL DC POWER SUPPLY Voltage: regulated or smoothed 10 to 14 V, max. ripple 100 mv Power: 3.5 W, current: 300 ma, Inrush current: 1000 ma Socket: Ø 5.5 mm with Ø 2 mm pin (positive) WEIGHT AND DIMENSIONS 1.2 kg (2.6 lb.) with batteries mm ( ) PCMCIA INPUT/OUTPUT Computer with PCMCIA/JEIDA standards release 1.0 Specifications Type 2260 Observer with BZ 7220 Software Specifications apply to 2260 Observer fitted with the supplied microphone and input stage, and running BZ7220 software SOUND LEVEL METER STANDARDS Conforms with the following: IEC (1979) Type 1 plus Amendments 1 and 2 IEC (1995) Octave Bands and 1/3-octave Bands Class 0 ANSI S Type 1 plus ANSI S1.4A 1985 Amendment ANSI S Octave Bands and 1/3-octave Bands, Order 3, Type 0-C, Optional Range MEASUREMENT AND CALCULATION STANDARDS Measurement and calculations can be made according to the following standards: ISO (3382, 354), DIN (52212), BS, NBE, SS, Sia, ÖNORM, NF, UNI, ASTM and NEN (5077) UNDERRANGE INDICATION Octave and 1/3-octave: 90dB below upper limit for each range setting, corresponding to less than 0.5 db error FREQUENCY WEIGHTING Lin frequency weighting A-weighting Instantaneous Fast (displayed, not stored) OCTAVE AND 1/3-OCTAVE BAND FILTERS Octave Band Centre Frequencies: 63 Hz to 8 khz 1/3-Octave Band Centre Frequencies: 50 Hz to 10 khz Real-time Frequency Range: 50 Hz to 10 khz centre frequencies INHERENT NOISE LEVEL (Inherent noise is the combination of the electrical noise and the thermal noise from the microphone at 20 C.) Typical values using a microphone Type 4189 with a nominal sensitivity: 1/3-octaves: 2 db at 1 khz, 8 db at 10 khz 1/1-octaves: 6dB at 1kHz, 12dB at 8kHz DETECTORS The analyzer contains several detectors working in parallel on every measurement: Octave Band Filters (8) or 1/3-octave Band Filters (24): Preweighted by Lin., each with a detector channel containing one linear averaging detector Overload Detector: Monitors the overload condition A-weighted: Broadband detector channel with Fast exponential time weighting INTERNAL GENERATOR Built-in pseudo-random noise generator Spectrum: Selectable between Pink and White Crest Factor: Pink noise: 4.4 (13 db) White noise: 3.6 (11 db) Bandwidth: Follows measurement bandwidth Lower limit: 50 Hz (1/3-Oct.) or 63 Hz (Oct.), Upper limit: 10 khz (1/3-Oct.) or 8 khz (Oct.) Output Level: Independent of bandwidth Max.: 1V rms (0 db) May be set in 1 db steps 0 60 db When bandwidth is changed, the level for all bands is automatically adjusted to comply with the set output level Turn-on time and Turn-off time: Equivalent to RT = 70 ms Repetition Period: 175 s Output Connector: Auxiliary 1 output Control: See Measurement Control EXTERNAL GENERATOR Selectable as alternative to Internal Generator For controlling external noise generator Levels: 0 V (Generator off), 4.5 V (Generator on) Rise-time and Fall-time: 10 s Control: See Measurement Control. MEASUREMENTS Instantaneous: For display, no storage Live spectrum L eq with a short averaging time Range: Follows setting in Levels and Reverberation Time Generator: Turned on and off manually Reverberation Time: T20 and T30 in octave or 1/3-octave bands Decays are measured and stored, using averaging times between 8 and 96 ms, depending on bandwidth and decay time Manual entry: After measurement, the value in each band, for each position, may be changed by user entry Broadband average: The arithmetic average of the Reverberation Time for selected bands is calculated and displayed (not stored) Impulse excitation: When level (say from starter pistol) exceeds user selected trigger level, the decay is recorded and backwards integration performed (Schroeder method) Generator: Controlled automatically Repetition: Decays can be repeated automatically up to 99 times (ensemble averaging) Averaging: up to 25 T20 and T30 measurements can be averaged (arithmetic averaging) T20 and T30 calculation: From slope in evaluation range Slope estimation: Least squares approximation 10
11 Status indications: Overload, underrange, start time, T20 T30% Correlation Coefficient; extensive list of Status codes RT range: Max s, min s, depending on bandwidth MEASUREMENT CONTROL Manual or semi-automatic. Measurements are started manually and can be automatically stored on completion of measurement. The noise generator is turned on and off automatically With Inst. spectrum on display, the generator can be turned on and off manually for checking Selected frequency bands can be measured serially, i.e., one by one in automatic sequence MEASUREMENT DISPLAYS T2: Shows the spectrum of reverberation times (T20 or T30) measured in the receiving room. Also, decay curve can be shown for each centre frequency Spectrum: Octave or 1/3-octave band spectrum. Y-axis can be zoomed db(a): Instantaneous level is shown as a column next to the spectrum, with cursor readout.the graphical displays have cursor read-out facilities DISPLAY RESOLUTION Levels: 0.1 db Reverberation Time: 0.01 s DISPLAY Update Rate: Instantaneous typically 5 times per second AUXILIARY OUTPUTS Aux. 1: noise generator output Aux. 2: Input signal monitor output can be set to either monitor Input signal with variable attenuation from 0 to 80 db in 1 db steps, or can be switched Off to reduce power consumption HELP AND USER LANGUAGES Concise context-sensitive Help throughout in English, German, French, Italian, Spanish or Czech 11
12 Ordering Information Note: for upgrades and kit options, contact your Brüel & Kjær representative Type 2260 I Type 2260 J BZ 7220 Modular Precision Sound Analyzer with Sound Analysis Software BZ 7219 Modular Precision Sound Analyzer with Sound Analysis Software BZ 7219 and Reverberation Time Software BZ 7220 Reverberation Time Software Accessories Included with Type 2260 I BZ 7219 Sound Analysis Software Type 4189 Prepolarized Free-field ½ Microphone ZC 0026 Input Stage ZF db Capacitive Attenuator UA 1236 Protective Cover DH 0696 Wrist Strap KE 0342 Shoulder Bag (with room for 2260 and 4231) 6 QB V LR 14/C size alkaline cells UA 0237 Large Round Windscreen AO pin to 25-pin PC or Serial Interface Cable Optional Accessories CALIBRATION Type 4226 Multifunction Acoustic Calibrator Type 4228 Pistonphone Type 4231 Sound Level Calibrator 2260 CAI Accredited Initial Calibration of Type CAF Accredited calibration of Type CAP Accredited calibration with pre-calibration of Type 2260 INTERFACING Type 7815 Noise Explorer data viewing software Type 7820 Evaluator data viewing and calculation software Type 7825 Protector software for calculation of Personal Noise Exposure Type 7830 Qualifier Reverberation Time Viewing and Calculation Software Type 2322 Portable Printer AO pin to 25-pin PC or serial printer interface cable UL MB ATA Flash Memory Card MAINS POWER SUPPLIES ZG 0386 EU Version ZG 0387 UK Version ZG 0388 US Version MEASURING Type 3592 Outdoor Measuring Gear (see Product Data BP 1744) AO 0440 AC input/output cable AO m Microphone Ext. Cable AO m Microphone Ext. Cable AO to Jack Cable AO 0586 Cable from 2260 to Audio input on a PC KE 0371 Carrying Case for 2260 and accessories UA 0237 Large Round Windscreen UA 0459 Small Round Windscreen UA 1317 Microphone Holder UA 1404 Outdoor Microphone Kit UA 0522 Headphones Adaptor UA 0587 Tripod UA 0801 Small Tripod Type 4295 Omnisource Type 4296 OmniPower Sound Source with Tripod Type 2716 Power Amplifier KE 0358 Flight Case AO m Cable from 2260 to 2716 AQ 0621 Bridging Cable for 2716 output AQ m Cable from 2716 to 4296 TRADEMARKS Windows and MS-DOS are registered trademarks of Microsoft Corporation in the United States and/or other countries IBM and Proprinter are registered trademarks of International Business machines (IBM) Corporation Brüel & Kjær reserves the right to change specifications and accessories without notice. BP /02 Rosendahls Bogtrykkeri HEADQUARTERS: DK-2850 Nærum Denmark Telephone: Fax: [email protected] Australia (02) Austria Brazil (011) Canada (514) China (86) Czech Republic Finland (0) France (01) Germany 06103/ Hong Kong Hungary (1) Ireland (01) Italy Japan Republic of Korea (02) Netherlands (31) Norway Poland (22) Portugal (1) Singapore (65) Slovak Republic Spain (91) Sweden (08) Switzerland (0) Taiwan (02) United Kingdom (0) USA Local representatives and service organisations worldwide
PRODUCT DATA 2260/BZ 7206/BZ 7210. Modular Precision Sound Analyzer 2260 Investigator including BZ 7206 and BZ 7210 Sound Analysis Software
PRODUCT DATA Modular Precision Sound Analyzer 2260 Investigator including BZ 7206 and BZ 7210 Sound Analysis Software 2260 Investigator is a battery-operated, hand-held, programmable sound analyzer. Its
PRODUCT DATA. 2238 Mediator Class 1 Integrating Sound Level Meters
PRODUCT DATA 2238 Mediator Class 1 Integrating Sound Level Meters When it comes to investing in a sound level meter, it s important to get an instrument that can keep up with you as your measurement requirements
Noise Monitoring Software, version 7.0 Types 7802 and 7840
PRODUCT DATA Noise Monitoring Software, version 7.0 Types 7802 and 7840 The basic software packages Noise Monitoring Software Types 7802 and 7840 are the central point in any Brüel & Kjær noise monitoring
Product Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301
Product Data Thermal Comfort Data Logger Type 1221 Including Application Software Type 7301 USES: For measuring all physical parameters necessary to evaluate heat stress and thermal comfort For evaluating
SC-30 INTEGRATING SOUND LEVEL METER REAL TIME FREQUENCY ANALYZER
SC-30 INTEGRATING SOUND LEVEL METER REAL TIME FREQUENCY ANALYZER Type 1 integrating sound level meter meeting ANSI S1.4:83 (A1 :85), ANSI S1.43:97 standards. Octave band spectrum analyser 31,5 Hz 16 khz.
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
PRODUCT DATA. PULSE WorkFlow Manager Type 7756
PRODUCT DATA PULSE WorkFlow Manager Type 7756 PULSE WorkFlow Manager Type 7756 provides a range of tools for automating measurement and analysis tasks performed with Brüel & Kjær PULSE. This makes it particularly
APPLICATION NOTE. Ear Simulator for Telephonometry. Use of Wideband Ear Simulator Type 4195
APPLICATIO OTE Ear Simulator for Telephonometry Use of Wideband Ear Simulator Type 4195 Wideband Ear Simulator Type 4195 has been designed to match the ear simulators in Head and Torso Simulator Type 4128-C
Sound Level Meters Nor131 & Nor132
Product Data Sound Level Meters Nor131 & Nor132 Applications Noise hazards in the workplace Prescription of hearing protection Environmental noise investigations Product noise testing Noise labeling Features
PRODUCT DATA. Uses and Features
2250 Light has been developed specifically for measuring occupational, environmental and product noise, while complying fully with all the relevant national and international standards. Extensive user
Integrating Sound Level Meter and Datalogger
USER GUIDE Integrating Sound Level Meter and Datalogger Model 407780A Introduction Thank you for selecting the Extech Instruments Model 407780A. This device is shipped fully tested and calibrated and,
CASE STUDY. Sarakasi Theatre Nairobi, Kenya Room Acoustical Measurements and Modelling. Africa Room Acoustics DIRAC and ODEON
CASE STUDY Sarakasi Theatre Nairobi, Kenya Room Acoustical Measurements and Modelling Africa Room Acoustics DIRAC and ODEON In November 2008, room acoustical measurements were performed inside the Sarakasi
PRODUCT DATA. Human Vibration Analyzer Type 4447
PRODUCT DATA Human Vibration Analyzer Type 4447 Brüel & Kjær's Human Vibration Analyzer Type 4447 is a portable system designed for those who work with human vibration and require quick and reliable results
Bosch Rexroth The Drive and Control Company. Telehandlers Mobile concrete mixers Cranes Drilling equipment Surface repair machinery Pavers
CASE STUDY Bosch Rexroth AG Hydraulics for the Automotive Industry Sound and Vibration R&D Germany Automotive PULSE, customised software, transducers Bosch Rexroth AG is a 100% subsidiary of Robert Bosch
www.burntec.com User's Guide Integrating Sound Level Datalogger Model 407780
User's Guide Integrating Sound Level Datalogger Model 407780 Introduction Congratulations on your purchase of the Extech 407780 Integrating Sound Level Meter. The 407780 with programmable integrating time
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
CASE STUDY. Automotive Components. Bosch Drancy, France Brake NVH Testing. Braking Systems. France. Automotive. PULSE, Transducers
CASE STUDY Bosch Drancy, France Brake NVH Testing France Automotive PULSE, Transducers The world-renowned Bosch group is a major producer of a vast range of automotive components. The company is an OEM
CASE STUDY. History. National Renewable Energy Laboratory Testing Wind Turbine Power Generators using PULSE. United States of America
CASE STUDY National Renewable Energy Laboratory Testing Wind Turbine Power Generators using PULSE United States of America Industrial Products PULSE The National Renewable Energy Laboratory (NREL) is operated
CASE STUDY. Environnement S.A. Industrial Site Noise Monitoring
CASE STUDY Environnement S.A. Industrial Site Noise Monitoring France Environmental Noise Monitoring Terminals Environnement S.A., based outside Paris, France, is a cutting edge company in the environmental
APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS
APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS Conditioning Amplifier by Claus Lindahl and Bernard Ginn, Brüel&Kjær When making vibration measurements,
User Manual. CEL-63x Environmental Noise Meter HB3356-02. User Manual
User Manual CEL-63x Environmental Noise Meter HB3356-02 User Manual CASELLA MEASUREMENT Regent House, Wolseley Road, Kempston, Bedford, MK42 7JY, U.K. Phone: +44 (0) 1234 844 100 Fax: +44 (0) 1234 841
Agilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment
AUROLEX Plug and Play Monitoring The best ways to achieve a cleaner, safer environment R AUROLEX MONITORING SYSTEEM The flexible Aurolex Monitoring System offers users the ability to simultaneously measure
2398 9 khz to 2.7 GHz Spectrum Analyzer
Spectrum Analyzers 2398 9 khz to 2.7 GHz Spectrum Analyzer A breakthrough in high performance spectrum analysis, combining cost effectiveness and portability in a new lightweight instrument 9 khz to 2.7
1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
Agilent 8762/3/4A,B,C Coaxial Switches
Agilent 8762/3/4A,B,C Coaxial Switches Technical Overview High performance switches for microwave and RF instrumentation and systems Agilent Technologies offers a ver satile line of multiport coaxial switches.
FREJA 300 Relay Testing System
Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
CASE STUDY. The Company and its History. Outils WOLF EU Directive and Production-line Testing, R&D. France. Consumer Products
CASE STUDY Outils WOLF EU Directive and Production-line Testing, R&D France Consumer Products Sound Level Meters, Transducers, Software Outils WOLF group, based at Wissembourg, in northern France, manufactures
Sound level meters and accessories
PRODUCT OVERVIEW Sound level meters and accessories US customers: buy online at store.bksv.com CONTENTS INTRODUCTION Introduction 3 Sound Calibrator 4231 4 Noise Dose Meter 4448 5 Integrating-averaging
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
CASE STUDY. Mazda Motor Corporation. Mazda Motor Corporation. Operational Modal Analysis. Japan. Automotive. PULSE, Software, Transducers
CASE STUDY Mazda Motor Corporation Operational Modal Analysis Japan Automotive PULSE, Software, Transducers Mazda Motor Corporation, based in Hiroshima, Japan, commenced automobile production in 1931.
Distributed by TestEquity LLC 800-950-3457 http://www.testequity.com
Meters Meters Extech sound meters include all the features/functions needed for basic noise level surveys or to meet the requirements for OSHA compliance, community noise ordinances or machine noise evaluation.
How To Use A Detector 2
Technical Information TI No. WL 80-62 E January 2003 Detector II the mobile phone among the data collectors Maintenance Products Application Condition-based maintenance Principle of operation Application
CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
AC3200 INTELLIGENT BROADBAND AMPLIFIER
Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both
Physical Specifications (Custom design available.)
Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given
FFT Spectrum Analyzers
FFT Spectrum Analyzers SR760 and SR770 100 khz single-channel FFT spectrum analyzers SR760 & SR770 FFT Spectrum Analyzers DC to 100 khz bandwidth 90 db dynamic range Low-distortion source (SR770) Harmonic,
3M Occupational Health & Environmental Safety Division 3M SoundPro Sound Level Meters SE/DL Series. Easy. Functionality
3M Occupational Health & Environmental Safety Division 3M SoundPro Sound Level Meters SE/DL Series Easy to Use Functionality Advanced Sound Level Monitoring The 3M SoundPro Sound Level Meters SE/DL provides
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
1.5 GHz Active Probe TAP1500 Datasheet
1.5 GHz Active Probe TAP1500 Datasheet Easy to use Connects directly to oscilloscopes with the TekVPI probe interface Provides automatic units scaling and readout on the oscilloscope display Easy access
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
Handheld portable appliance testers
PAT100 SERIES Handheld portable appliance testers PAT100 SERIES Handheld portable appliance testers Simple Tick/Cross, pass/fail indication plus measurement Battery powered with rechargeable options Includes
NoiseMeters. www.noisemeters.com. dosebadge. Monitoring Personal Noise Exposure
NoiseMeters dosebadge Monitoring Personal Noise Exposure Small size and weight with simple operation No cables or controls on the dosebadge Reduces damage and tampering Very strong construction Meets IEC
Inspired Partnership. Software Support Directed by You
Inspired Partnership Software Support Directed by You PARTNERSHIP YOUR GUARANTEE Investing in new test and measurement equipment in today s fast-moving, competitive world is serious business. In addition
BASIC SOUND LEVEL METERS
BASIC SOUND LEVEL METERS Typical Applications: Occupational Noise Measurements Noise Ordinance Enforcement Community Noise Assessment Fire & Emergency Notification Alarm Testing Maintenance Inspections
Sound Level Meters. Product Overview. www.bksv.com
Sound Level Meters & Accessories Product Overview www.bksv.com CONTENTS 3 Introduction 4 Sound Calibrator 4231 5 Noise Dose Meter 4448 6 Integrating-averaging Sound Level Meter 2240 7 Integrating Sound
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
LMS Test.Xpress Powering personal productivity
LMS Test.Xpress Powering personal productivity LMS Test.Xpress Powering personal productivity Traditional analyzers have proven to be one of the most flexible tools to qualify a product s noise and vibration
NI USB-6008/6009 OEM USER GUIDE
USER GUIDE NI USB-6008/6009 OEM This document provides information about the dimensions, connectors, and other components of the National Instruments USB-6008/6009 OEM device. For more information about
CLIO 8 CLIO 8 CLIO 8 CLIO 8
CLIO 8, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure: - electrical networks - electronic equipment - loudspeaker
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
TORKEL 820 Battery Load Unit
TORKEL 820 Lightweight Expandable system Rugged and reliable for field use Test without disconnecting the battery from the equipment it serves Description During a power outage, crucial telecommunication
Agilent Automotive Power Window Regulator Testing. Application Note
Agilent Automotive Power Window Regulator Testing Application Note Abstract Automotive power window regulator tests require the use of accurate data acquisition devices, as they cover a wide range of parameters
Agilent E6832A W-CDMA Calibration Application
Agilent E6832A W-CDMA Calibration Application For the E6601A Wireless Communications Test Set Data Sheet The next generation of mobile phone manufacturing test. E6601A is the newest test set from Agilent
802.11ac Power Measurement and Timing Analysis
802.11ac Power Measurement and Timing Analysis Using the 8990B Peak Power Analyzer Application Note Introduction There are a number of challenges to anticipate when testing WLAN 802.11ac [1] power amplifier
PRODUCT DATA. Measurement Partner Suite BZ-5503 from software version 4.6. Uses, Benefits and Features
PRODUCT DATA Measurement Partner Suite BZ-5503 from software version 4.6 Modular and optimized for the post-processing of measurement data, Measurement Partner Suite provides essential postprocessing tools
www.64817.com www.64817.com www.64817.com Integrating Sound Level Meters LA-5570/5560/2560
www.64817.com www.64817.com www.64817.com Integrating Sound Level Meters LA-5570/5560/2560 High-functionality Integrating Sound Level Meters Type1Sound Level Meters High sensitivity Wide band LA-5570/5560
Everything you need for protection scheme testing
Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full
5000V Graphical Megohmmeter Model 5070
5000V Graphical Megohmmeter Model 5070 The Model 5070, the latest design in 5000V Megohmmeters, is the most innovative product in its class on the market today. The features and functions incorporated
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer Application Note Introduction In a pulsed radar system, one of the key transmitter-side components
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
Frequency selective monitoring and logging of environmental electromagnetic fields
FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser
Impedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits
TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet TCA-N TekConnect-to-N DC to 11 GHz (Instrument Dependent) 50 Ω Input (Only) TCA-SMA TekConnect-to-SMA DC to 18 GHz (Instrument Dependent)
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Soundbook. The 2nd generation of our Soundbook acoustics analyzer - now based on the new 24 bit Apollo hardware platform
Soundbook TM The 2nd generation of our Soundbook acoustics analyzer - now based on the new 24 bit Apollo hardware platform Sound level measurement Frequency analysis Signal recording Human vibration measurement
TDA2003 10W CAR RADIO AUDIO AMPLIFIER
TDA2003 10W CAR RADIO AUDIO AMPLIFIER DESCRIPTION The TDA 2003 has improved performance with the same pin configuration as the TDA 2002. The additional features of TDA 2002, very low number of external
PRODUCT INFORMATION. Insight+ Uses and Features
PRODUCT INFORMATION Insight+ Traditionally, CAE NVH data and results have been presented as plots, graphs and numbers. But, noise and vibration must be experienced to fully comprehend its effects on vehicle
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
PHONE MANAGER INDEX. page
PHONE MANAGER INDEX page 1 HARDWARE... 4 1.1 Requirements... 4 1.2 Indicators... 4 1.3 Hardware Configuration... 5 1.4 Hardware Installation... 5 2 SOFTWARE... 7 2.1 Software Installation... 7 2.2 Use
R&S ZVA Vector Network Analyzer Specifications
www.atecorp.com 8-44-ATEC (2832) R&S ZVA Vector Network Analyzer Specifications ZVA_dat-sw_en_523-568-22_v_cover.indd Data Sheet. E stablished 98 Advanced Test Equipment Rentals Test & Measurement 4.5.22
Continuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057 Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total emf values Magnetic fields monitoring from
MINIMAT-EC-Servo Screwdriver Spindles
Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range
NI USB-5681 RF Power Meter Specifications
NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour
PRODUCT DATA. PULSE Data Manager Types 7767-A, -B and -C. Uses and Features
PRODUCT DATA PULSE Data Manager Types 7767-A, -B and -C PULSE Data Manager is a family of data management solutions that enables measurements from PULSE or any of its applications to be labelled with metadata
Acoustic Terms, Definitions and General Information
Acoustic Terms, Definitions and General Information Authored by: Daniel Ziobroski Acoustic Engineer Environmental and Acoustic Engineering GE Energy Charles Powers Program Manager Environmental and Acoustic
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Intensity Component Analysis: Theory
PRODUCT DATA PULSE In Situ Absorption BZ-5642 PULSE Intensity Component Analysis BZ-5641 PULSE Panel Contribution BZ-5640 PULSE In Situ Absorption BZ-5642, PULSE Intensity Component Analysis BZ-5641 and
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
W- Series. Features: WOB. Mechanical Data Case : Moulded plastic. Lead : Solder plated. Weight : 1.10 grams. Page <1> 15/07/08 V1.
Features: Surge overload ratings to 40 amperes peak. Ideal for printed circuit board. Reliable low cost construction. High temperature soldering guaranteed: 260 C/10 seconds/0.375inch (9.5mm) lead lengths
Vibration analysis and monitoring Compact. Powerful. Modern technology.
Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device
Agilent E363xA Series Programmable DC Power Supplies. Data Sheet
Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation
PRODUCT DATA. Uses and Features
PRODUCT DATA Acoustic Test Consultant Type 7761 with Robot Option BZ-5370, PULSE Position Detection Option for Acoustic Test Consultant BZ-5611 and Noise Source Identification Type 7752 Acoustic Test Consultant
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks
R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks Broadcasting Product Brochure 01.00 R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage
Measuring electric and magnetic fields
NARDA BROADBAND FIELD METER NBM-520 Measuring electric and magnetic fields ranging from high frequency to microwaves Non-directional measurement using isotropic probes for applications in the frequency
AN1991. Audio decibel level detector with meter driver
Rev. 2.1 20 March 2015 Application note Document information Info Keywords Abstract Content SA604A, LM358, RSSI, cellular radio The SA604A can provide a logarithmic response proportional to the input signal
TDA2040. 20W Hi-Fi AUDIO POWER AMPLIFIER
20W Hi-Fi AUDIO POWER AMPLIFIER DESCRIPTION The TDA2040 is a monolithic integrated circuit in Pentawatt package, intended for use as an audio class AB amplifier. Typically it provides 22W output power
