Powersonic. Ultrasonic Table Top Cleaners
|
|
|
- William Lynch
- 9 years ago
- Views:
Transcription
1 Powersonic Ultrasonic Table Top Cleaners
2 Common features off all POWERSONIC Table Tops Type D/D-HF Digital display is showing: - Chosen operation time in standby mode - Remaining operating time - Operating time adjustable from 1 min up to 99 min - Continuous operating mode - Chosen liquid temerature in standby/operating mode - Adjustable temp. from 1 degree up to 80 degrees - Heaters protected against overheating - Degas mode Chosen ultrasonic power: - power is adjustable from 10 % up to 100 % power - Constant ultrasonic power independent of liquid level, liquid temperature and load - Double wave ultrasonic for perfect cleaning results
3 Power cord with mains plug for Europe (EU/F); plug für CH, DK, UK on request Housing and tank are made of stainless steel CN 18/10 EN 631 Special heat and noise protection Model S to D have an ultrasonic frequency of 45 khz Model D/HF has an ultrasonic frequency of 132 khz Mains voltage 230 V 50/60 Hz single phase 24 month warranty from delivery date
4 Price list/technical Data POWERSONIC Table Top
5 Price list / Technical Data POWERSONIC Table Tops accessories
6 Powersonic Industrial Line Ultrasonic Cleaning - Baths Either side-wall mounting or bottom mounting of the ultrasound Digital adjustable cleaning time, heating and power Special heat isolation and noise protection External Generator Capacity from 40 to 360 l Frequency 25 khz, 40 khz Made out of stainless steel / Rinsing bath with the same design Other capacities or frequencies on request
7 Common features of all POWERSONIC Industrial Line Cleaners Digital Display is showing: - chosen operation time in standby mode - Remaining operation time - Operating time adjustable from 1 min up to 99 min - Continuous operating mode - Chosen liquid temprature in standby/operating mode - Adjustable temp. from 1 degree up to 80 degrees - Heaters protected against overheating with liquid sensor - Degas mode Chosen ultrasonic power: - adjustable from 40% to 100% power - Constant ultrasonic power independent of liquid lever, liquid temperature and load - Double wave ultrasonic for perfect cleaning results - Standart cable length between tank an external generator 5 m
8 - Available with ultrasonic power from the bottom or the side walls - All models have an external generator - All models are available in a frequency of 25 khz and 40 khz, others on request - Skimming on request - Housing and tank made of stainless steel / Units have special heat isolation and noise protection - Main voltage: - Model 1218 and 1810 AC 230V (1ph.L/N/PE) - Model 2210 up to 2446 AC 230/400V (3ph.L/N/PE) Waranty: - 12 months from delivery for traders - 24 months from delivery for end users
9 Technical Data Powersonic Industrial- Line Ultrasonic baths
10 Technical Data Powersonic Industrial-Line Rinsing bath without Ultrasonic
11 Powersonic Industrial-Line External Controll Common features of all POWERSONIC Tanks: - operationg status output signals (Potential free relays contacts) ULTRASOUND ON / OFF HEATING ON / OFF HEATING ACTIVE / STAND-BY LIQUID LEVEL OK / LOW LEVEL - Input signal binary, potential free optocoupler input, 24 V-logic for: Ultrasonic on/off Heating on/off - Input signal analog (control signal 10V or 20 ma referring to GND) for: Ultrasonic power adjustment 40% to 100% Liquid temperature adjustment 20 C to 80 C - Output signal analog (control signal 10V referring to GND for: Actual value of liquid temerature
12 Common features of all POWERSONIC heated rinsing tanks: - Output signal analog for (Potential free relays contacts) HEATING on / off HEATING ACTIVE / STAND-BY LIQUID LEVEL OK / LOW LEVEL - Input signal binary, Potential free optocoupler input, 24 V-logic for: Heating on/off - Input signal analog (Control signal 10V or 20 ma reffering to GND) for: Liquid temerature adjustment 20 C to 80 C - Output signal analog (control signal 10V referring to GND) for: Actual value of liquid temerature
13 OPERATING MANUAL Powersonic MW-GT/GTI/GPI/GPS Ultrasonic Cleaning Systems Ultrasonic Transducers and Modular Ultrasonic Generators
14 Saftey Information Please read the following saftey information carefully before operating the Ultrasonic components - The correct use and Technical Specification of the ultrasonic components are described in this documentation and must be followed - Installation of the ultrasonic generator must be done by a skilled and qualified electrician. You have to comply with the relevant national standards for safety and mechanical and electrical installation. - Operation ot he ultrasonic generator must be done by trained staff. Inadeqaute operation can result in non-repairable damages or injury. - The technical details of the ultrasonic components must be respected. - Adequate ventilation of the ultrasonic generator has to be guaranteed. - The ultrasonic power supplied to the bath liquid ist transformed into heat. With insufficient heat dissipation, it can result in hot steam or ignition, depending on the cleaning agent.
15 Danger of fire or explosion! Do never operate the ultrasonic generator and the transducer without bath liquid. The immersible transducer must be completely immersed also the membrane of the plate type transducer. The liquid must be able to absorb and dissipate the power (heat). Only use bath liquids permitted for use with ultrasonic technology, regarding their possible enviromental effects and their inflammability. Unplug and disconnect the system properly before maintenace or repair of the system. Mechanical shock or thermal displacement of the ultrasonic transducer can generate static voltages if not connected (>1000V). Before handling, short terminals. Follow the national standards and keep contact to your application manufacturer or/and cleaning agent supplier.
16 Installation Direction of Power Dissipation: Immersible- and plate type transducers are dissipating the ultrasonic power vertically to the surface, PushPull transducers are dissipating the ultrasonic power radial from resonator rod. Minimum distance to cleaning goods: 25 / 30 khz transducer: Bmin = 200mm 40 / 45 khz transducer: Bmin = 200mm
17 PushPull and SinglePush Transducers Bottom Mounting: Min. distance to bottom: For all frequencies: Amin = 120 mm Vertical, horizontal, wall Mounting: Min. distance to side walls: Amin = 120 mm Min. distance to cleaning goods: Bmin = 200 mm Min. distance to other transducers: Cmin = 120 mm Free hanging installation possible. Transducer must be fixed at the driver heads with one fixed bearing and one moving bearing. SinglePush drivers only need to be fixed with one bearing.please note that SinglePush transducer with a length of 495 mm and more must be mounted vertical.
18 Optimized Reflexion oh the Sonic Waves Max. reflexion of the sonic waves expansion space Overflow tank, fittings or similar acoustic damping objects harm the ultrasonic effect The transducers are to be installed staggered so that the individual waves can overlap 25 khz transducer: D = 50 mm 30 khz transducer: D = 40 mm 40 khz transducer: D = 30 mm 45 khz transducer: D = 30 mm
19 Sample of documents
20 Sample of documents
21 Sample of documents
22 Sample of documents
23 The PushPull
24 Dimensional drawing
25 Data scheet PushPull Transducer 25 khz
26 Data scheet PushPull Transducer 30 khz
27 Data scheet PushPull Transducer 40 khz
28
29
30 Appendix PushPull and SinglePush Transducers
31 The SinglePush
32 SinglePush 25 khz
33 Data sheet SinglePush 25 khz
34 SinglePush 30 khz
35 Data sheet SinglePush 30 khz
36 MW Generators Measurement: 28 TE : 194 x 184 x 397 mm ( H x W x D) 42 TE : 222 x 236 x 411 mm ( H x W x D) 63 TE: 222 x 342 x 411 mm ( H x W x D) 84 TE : 222 x 449 x 411 mm ( H x W x D) Power supply : 28 TE : AC 230V, 16A 42 TE : AC 230V, 16A 63 TE : AC 230/400V, 3 x 16 A 84 TE : AC 230/400V, 3 x 32 A
37 OPERATING MANUAL POWERSONIC MW-GT/GTI/GPI/GPS Ultrasonic Cleaning Systems Ultrasonic Transducers and Modular Ultrasonic Generators
38 Controls and Indicators *1) only with generator version GPI, *2) only with connected level sensor (Option), *3) not with external power setting (Option)
39 Technical Data The technical data are valid for a single module. Connected to the power supply, the total power consumption per housing has to be considered. Application: Ultrasonic cleaning, mixing and separating applications for industrial use, special applications Design: Module 14TE resp. 28TE / 4HE for mounting in corresponding 19 -housing Output: HF-Voltage for operation of matched ultrasonic transducers frequency approx.: 25 khz, 30 khz, 40 khz, 45 khz, 58 khz, 132 khz, 192 khz
40 Interface analog / binary (DSUB 25 pole socket) - input/output protected up to DC30V - Non-listed connections resp. The connections of non-assembled modules are not connected - Ground potential GND is connected to protective earth (PE) Pin no. With assembly of 84TE-5 cases equipped with generator modules series MW 3000 GTI (module with 28 TE). Pin no. With assembly of the 28TE-1, 42TE-2, 63TE-3 and 84TE-5 cases equipped width generator modules series MW GT/GTI/GPI/GPS (module width 14TE) and assembly of 42TE-2 cases with generator modules series MW 3000 GTI (module width 28TE)
41 Service Information Modul Generators MW GT / GTI / GPI / GPS & MW 3000 GTI-Series
42 Top view control board: NOTES: Unit is out of warranty, if settings of the controlboard were changed! Only skilled persons were allowed to make changes, generator or transducer damages can occur!
43 Controls and Indicators
44 Interface for Connection to Host System (SPS, PLC, etc.) RS485 (default): Parameter: 19200, N, 8, 1 Protocol: MW-internal Cable length: approx. max. 1200m (with shield cable and proper bus termination) Mode: half duplex No. of Units: 247 units per bus 32 per bus segment, can be extended with off-the-shelfrepeaters RS232 Parameter: 19200, N, 8, 1 (option, instead Protocol: MW-internal RS485) Cable length: approx. max. 15m (with shield cable) Available wit h 28TE-1 and 42TE-2 housing only, no bus operation possible, each module needs an own interface.
45 Information The names of the interface lines A and B of the RS485 are not standardized, it is possbile, that these names were interchanged or named differently at other RS485-components depending on manufacturer. If a communication does not work between the units, the wires A and B should be interchanged. This is applicable only, if all A bus termination should also be added generally.
46 Identification of Circuits / Isolation Power supply: Output: Interfaces: primary circuit secondary circuit ELV-cricuits Galvanic isolation between - power supply and output isolation voltage AC1000V - Interfaces and output, isolation voltage AC250V - Power supply and interfaces isolation voltage AC250V Moisture degree: 2 Over voltage catgory: III Information: The minus-pin of output and GND of interfaces are connected to protection earth (PE).
47 Technical Information Ultrasonic Generator: DANGER: A loadable neutral line is absolutely needed! Environment Conditions: Max. ambient temperature: Humidity: IP-class according IEC 529 / IP: +40 C (104F) max. 70% non condensing module without housing IP00 module installed in housing IP20 A clearance of min. 150mm behind the housing must be provided, do not cover the air inlet and outlet.
48 Technical Information Interface RS232 (9-pole DSUB plug, only for TMI/PMI/SMI/HMI) Information: for connection to a standard RS232 PCinterface a direct cable 1:1 socket/socket can be used. Interface RS485 (9-pole DSUB socket, only for TMI/PMI/SMI/HMI) Information: for connecting several housings and PLC, only the lines A, B and GND have to be used. The naiming of the lines A and B are not standardized. Therefore it is possible, that these markings of RS485.compenents of third party suppliers are interchanged or named completely different.
49 HF-Cable details Max. cables length: 30m The HF-cables must not wired bundled, sufficient heat dissipation must be guaranteed (single layer at wall, floor, cable, trough or cable tray). The HF-Cables of the generator moduls MW3000TMI/GTI-25kHz, MW2000TMI/GTI-25kHz and MW2000TMI/GTI-40kHz have to be wired at wall, floor, puched cable trough or cable tray single layer with gap distance same as diameter only.
50 Ultrasonic transducer Installation and Operation details, recommended distances, environment conditions
51 Recommended Circuit of RS485-Interface (according recommendation of ModBus-Organisation, Aug-2004)
52 Menu Structure User Level ( stand-by & sonic on mode)
53 Connection Plan Immersible- and Plate Type Transducer
54 Connection Plan PushPull - and SinglePush transducer:
55 Appendix HF-Cable Length / Cable Width Information: - the HF-cables must not wired bundled, sufficient heat dissipation must be guaranteed (single layer at wall, floor, cable trough or cable tray) - The HF-Cables of the generator modules MW3000GTI-25kHz and MW2000GTI- 40kHz have to be wired at wall, floor, punched cable trough or cable tray single layer with gab distance same as diameter only. - To avoid noise interference, the HFcables must not be wired together with line or signal cables. - Different cable lengths or layer systems are eventually possbile after consulting the manufacturer.
56 Installation Placing and Mounting: - The generator has to be installed on a flat surface, placed in an area not exposed to humidity, contamination and / or aggressive vapors. - Do not cover the air inlet at the front and the back of the generator. Unrestricted airflow has to be maintained all the time. - Behind the case must be a clearance of min. 150mm - For unsuitable envoironment conditions the generator can be assembled in a cabinet, possibly with an air condition unit (option).
57 Transducer Connection Each generator module can drive one transducer and is factory preset to type and frequency. For higher power immersible transducers or multifrequency transducers, several generator modules can drive one transducer. In this case the transducer has several connections. Generally the transducer outputs have to correlate to the matched generator modules For the electrical connection of the transducers to the generators, only shielded cables and adequate connections must be used.
58 Mounting instruction for corrugated hoses Rmin for DN8: Rmin for DN13: 100mm 140mm The corrugated hoses have to be protected from mechanical damages Don t drag along the ground or over sharp edges. Physical contact with other hoses or surrounding objects must be avoided during operation. The hose should not be bent tighter than the minimum bending radius, kinks and torsion must be voided.
59 Immersible- and Plate Type Transducer
60 PushPull / SinglePush Transducer
POWERSONIC MW-GT/GTI/GPI/GPS Ultrasonic Generator Instruction Manual.
Scotch Road P O BOX 7266 Trenton, NJ 08628. POWERSONIC MW-GT/GTI/GPI/GPS Ultrasonic Generator Instruction Manual. Manufacturing, service and sales: Martin Walter Crest Ultrasonics Corp. Scotch RD Ultraschalltechnik
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution
Table of Contents SAFETY WARNINGS...2 FCC Notice...2 Caution...2 Important Safety Instructions...2 Basic Instructions...3 Equipment checklist...3 Input Voltage...3 Power Indicator Light...3 Function Keys...3
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0
Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
REGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V01.3-2014-7
focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V01.3-2014-7 Thank you for purchasing our product. Please read this manual carefully before operation your set and retain it for future reference. FT55-P10
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
Problem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
Achat 115MA full-range speaker. user manual
Achat 115MA full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: [email protected] Internet: www.thomann.de
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Ultrasonic support removal tank
Ultrasonic support removal tank User guide and safety manual See inside for use and safety information. The Ultrasonic support removal tank automatically removes PLA support material from a printed ABS
CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
15-INCH TFT-LCD MONITOR
15-INCH TFT-LCD MONITOR 15RTV INSTRUCTION MANUAL Please read this manual thoroughly before use, and keep it handy for future reference. SAFETY INSTRUCTION.2-3 CAUTIONS....4 FCC RF INTERFERENCE STATEMENT.5
Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0
The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
SPL 2-00/-01 OPERATION INSTRUCTIONS
SPL 2-00/-01 OPERATION INSTRUCTIONS Powerline Ethernet Adapter 500 Mbps EN Read and keep Operation Instructions SPL 2-00/-01 Safety Notes Do NOT use this product near water, for example, in a wet basement
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
LOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
Wireless Powerlink II Receiver Set Active
Wireless Powerlink II Receiver Set Active Installation Guide Contents 1 General WirelessPowerlink Page 2 Package Contents Safety Instructions Page 3 Disposal of Old Electrical Devices Page 4 Installation
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
Installation Guide. DEVIreg 530. Electronic Thermostat. www.devi.com
Installation Guide DEVIreg 530 Electronic Thermostat www.devi.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive
Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC and 200 V DC
Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 5 V DC, 1 V DC and 2 V DC DESIGNING For more than 2 years Vitramon has supported the automotive industry
KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184
EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
User s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.
MPA-101 WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation. The lightning flash with arrowhead, within an equilateral triangle,
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
24 Wide Screen LED Monitor with HDMI
24 Wide Screen LED Monitor with HDMI USER MANUAL L24LE11B_MANUAL_EN_R1 Please read this manual carefully before using, and keep it for future reference. TABLE OF CONTENTS GETTING STARTED Monitor Stand
BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716
BATHROOM HEATER User's Manual Page 2...A515 Page 9...A716 BATHROOM HEATER User's Manual A515 SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS BEFORE USING THE HEATER. Dear customers, Thank you for selecting
When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.
BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
GSM Door Phone System
GSM Door Phone System System Installation, Setting and Operation Manual User Manual (263-S V1) Please read this user manual completely before operating this system and keep it in a safe place for future
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4
User Manual TABLE OF CONTENTS 1. BEFORE YOU BEGIN... 3 What Is Included... 3 Unpacking Instructions... 3 Claims... 3 Product at a Glance... 3 Safety Instructions... 4 2. INTRODUCTION... 5 Product Overview...
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.
Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
BeoLab 7-1 BeoLab 7-2. Guide
BeoLab 7-1 BeoLab 7-2 Guide CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service personnel. WARNING: To prevent
2.24. Pump Controller 704. Data Sheet
Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with
CR9971 2 Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use
ROBERTS Sound for Generations CR9971 2 Band Auto Set Dual Alarm Clock Radio Please read this manual before use Contents Contents... 1 Controls...2-5 Switching on... 6 Setting the time manually... 6 Setting
Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company
Instruction Manual Ultrasonic Cleaning Tank Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company No 1536, Jalan Perusahaan, Kawasan Perusahaan Bukit Tengah, 13600 Perai, Penang, Malaysia.
PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor
Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor Product Description GP6220 330x 724-US is an ultrasonic sensor with a built-in 3 colour LED indicator and part of the Dupline
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.
MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
WB/WBS 3, 4, 5, 7, 8, 11, 14, 30
INSTRUCTION MANUAL FOR WB/WBS 3, 4, 5, 7, 8, 11, 14, 30 WATER BATH PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 [email protected]
FT-100 Fire Training Fog Machine User Manual English
FT-100 Fire Training Fog Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual - English Safety Information Please read the following safety information carefully before operating
MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.
MX MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest
Remote Control Repeater
Remote Control Repeater Model: 40430 Operation Manual Ver.1.0 Operation Manual Remote Control Repeater Model: 40430 Thank you for purchasing Remote Control Repeater. We recommend that you read this manual
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
ECD 2 High Performance Balanced DAC. 24 Bit /192kHz. Owner's Manual
ECD 2 High Performance Balanced DAC 24 Bit /192kHz Owner's Manual EN Unpacking the ECD 2 Immediately upon receipt of the ECD 2, inspect the carton for possible damage during shipment. If the carton is
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
SES-FA1 USER MANUAL. Sescom SES-FA1 2-Channel Line Level Audio Over Fiber Extender Kit
SES-FA1 USER MANUAL Sescom SES-FA1 2-Channel Line Level Audio Over Fiber Extender Kit Sescom SES-FA1 2-Channel Line Level Audio Over Fiber Extender Kit Perfect for many types of studios, broadcasting,
TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.
High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output. Modular Design for Easy, Cost Effective Maintenance. Standardized Interface Allows Interchangeable Control Modules
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Senses SV series industrial monitor user manual
Industrial Monitors Senses SV series Senses SV19 / SV17 User manual (Issue A) Part No: 85090084 Page 1 of 25 Copyright Copyright 2008 Amplicon Liveline Ltd. All rights reserved. This publication, including
alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG
alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG Safety precautions Safety precautions The DSL modem alpha DSL WTM EG complies with the European norm EN60950 safety of information technology
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
