Sara Operating and Product Care Instructions. KKX US Issue 1 June 2003
|
|
|
- Bryan Daniel Lloyd
- 9 years ago
- Views:
Transcription
1 TM Sara 3000 Operating and Product Care Instructions KKX US Issue 1 June 2003
2 Introduction The vertical and horizontal lines printed in the margins adjacent to the text/illustrations in these instructions are for ARJO use only and should be disregarded by the reader. Some of the information contained in these instructions may become outdated, due to future product improvements. If you have any questions regarding these instructions or your lift, please contact ARJO or its approved distributor. ARJO Med. AB LTD ARJO products are patented or patent pending. Patent information is available by contacting ARJO Med. AB LTD. ARJO s policy is one of continuous development. ARJO therefore reserves the right to change specifications without notice. The content of this publication may not be copied either whole or in part without the consent of ARJO Med. AB LTD. ARJO Med. AB LTD. strongly advises and warns that only ARJO Company Designated Parts, which are designed for the purpose, should be used on equipment and other appliances supplied by ARJO, to avoid injuries attributable to the use of inadequate parts. Unauthorized modifications on any ARJO Med. AB LTD. equipment may affect its safety and are in breach of any equipment warranty. ARJO Med. AB LTD. will not be held responsible for any accidents, incidents or lack of performance that occur as a result of any unauthorized modifications to its products. The ARJO Company s Conditions of Sale make specific provision confirming no liability in such circumstances. Sara 3000 is a trademark of the ARJO Group. 2
3 Contents SECTION Page No. Foreword... 4 Safety Instructions... 5 Product Description/Function Parts referred to in this manual 6 Controls and Features... 7 Control Handset 7 Stop Button (red) 7 Automatic Cut-out: 7 Automatic Stop Function 7 System Failure Lower Override 8 Battery Discharge Indicator 8 Hour Meter 8 Chassis Castor Brakes 8 Foot Support 8 Lower Leg Straps 8 Adjustable Width Chassis Legs 8 Using Your Sara Using the Sara 3000 for Toileting and Transporting... 9 Standing Sling Battery Charging Care of Your Sara General Lift Care Enviromental Advice Periodic Testing Automatic Stop Function 16 Stop Button (red) 16 Adjustable Width Chassis Function 16 General Lift Condition 16 Servicing Advice Labels Technical Specification
4 Foreword Thank you for purchasing ARJO equipment. Your Sara 3000 is one of a series of quality products designed especially for hospitals, nursing homes and other health care uses. ARJO is dedicated to serving your needs and providing the best products available, together with training that will bring your staff the maximum benefit from every ARJO product. Please contact us if you have any questions about the operation or maintenance of your ARJO equipment. The letter (i) shown on the open book icon indicates information, and is an instruction to always read the operating instructions before use (see Fig. 14). The expected operational life of the ARJO lift is 10 (ten) years from the date of manufacture, providing that the following conditions are adhered to: Conditions The unit is regularly cared for and serviced in accordance with recommended, published Operating and Product Care Instructions and the Preventive Maintenance Schedule. The unit is maintained to the minimum requirements as published in the Preventive Maintenance Schedule. The servicing and product care, in accordance with ARJO requirements, must begin with the customer s first use of the unit. The equipment is used for its intended purpose only and is operated within the published limitations. Only ARJO designated spare parts should be used. The date of manufacture can be found in the second set of 4 digits of the serial number, for example STLA 0309 A (STLA = manufacturers code, 03 = year 2003, 09 = month September, A = charger country code). The remaining digits are the machine identification number. The expected life for other consumable products, such as batteries, fuses, lamps, safety belts, padded covers, and straps is dependent on the care and usage of the equipment concerned. Consumables must be maintained in accordance with the published Operating and Product Care Instructions and the Preventive Maintenance Schedule. All references to the patient in these instructions refer to the person being lifted, and references to the attendant refer to the person who operates the lift. References to left and right of the lift in these instructions are as viewed when you are standing at the rear of the Sara 3000, facing forward, as viewed from the control panel (see Fig. 1). Lifting operations in these instructions are described as if lifting a patient from a chair. The same operations can be performed effectively when lifting a patient from a wheelchair or sitting position on a bed, although a second attendant should support the patient if the patient lacks sitting balance. All operations in these instructions are described as if the attendant were using the control handset. Consumables The expected operational life for fabric slings is approximately 2 years from the date of manufacture. This life expectancy only applies if the slings have been cleaned, maintained and inspected in accordance with the ARJO Sling Information documents, the Operating and Product Care Instructions and the Preventive Maintenance Schedule. 4
5 Safety Instructions Before using your Sara 3000, familiarize yourself with the various parts and controls as illustrated in Fig. 1 and other illustrations. Then please read this whole manual thoroughly before operating your Sara Information in the manual is crucial to the proper operation and maintenance of the equipment, and will help protect the product and ensure that the equipment performs to your satisfaction. Some of the information in this booklet is important for your safety and must be read and understood to help prevent injury. If anything in the manual is confusing or difficult to understand, please call ARJO or its appointed distributor (the telephone number appears on the last page of this manual). Symbols used adjacent to the text in these instructions: Danger: Means: electrical hazard warning. Failure to understand and obey this warning may result in electrical shock. Warning: Means: failure to understand and obey this warning may result in injury to you or to others. Caution: Means: failure to follow these instructions may cause damage to all or part of the system or equipment. Note: Means: this information is important for the correct use of this system or equipment. This product has been designed and manufactured to provide you with trouble-free use. However, this product does contain components that, with regular use, are subject to wear. Warning: SOME OF THESE PARTS ARE CRITICAL TO ENSURE THE SAFETY IN OPERATING THE LIFT. THEY WILL NEED EXAMINING AND SERVICING ON A REGULAR BASIS AND MUST BE REPLACED AS NEEDED. Also, see the section entitled Care of Your Sara Warning: Use only ARJO slings that have been specifically designed for the Sara Warning: Do not overload the Sara 3000 beyond its approved lifting capacity. The Sara 3000 may be used on gentle slopes with caution. Do not attempt to manually lift the complete lift. Caution: Although it is manufactured to a high standard, the Sara 3000 and its accessories should not be left for extended periods in humid or wet areas. Do not under any circumstances spray the Sara 3000 or accessories (excluding slings or ARJO approved wet environment equipment) with water, such as under the shower. Warning: Before lifting a patient, it is advisable to familiarize yourself with and understand the operation of the various controls and features of the Sara 3000 and to carry out any action or inspection procedure before lifting a patient. Warning: The Sara 3000 has been designed as a mobile lift for raising and transporting patients in hospitals and care facility environments, and should only be used for this purpose. This product is intended to be operated entirely by an attendant. The patient should not perform any function relating to the control of this product. A second attendant may be required with certain patients. 5
6 Product Description/Function Parts referred to in this manual Control Panel 7 Fig Clip Attachment Points 2. Battery Pack 3. Steering Handgrips 4. Control Handset 5. Motor/Actuator 6. Knee Support 7. Foot Support with Anti-skid Material 8. Rear Castors with Brake 9. Stop Button (red) and Reset Button 10. Dual Up/Down Control 11. System Failure Lower Override 12. Battery Discharge Indicator and Hour Meter 6
7 Product Description/Function Unpack the battery pack supplied, and fully charge it as described in the section titled Battery Charging. When the battery pack is fully charged, disconnect the electric power, remove the pack from the charger, and insert it fully back into the Sara 3000 battery compartment. An electrical connection is made automatically. Ensure that the green button (located on the control panel above the battery) is pushed in. Ensure that the sling is available. Controls and Features Control Handset: A semi-remote control unit attached to the lift by an extending cable. The handset controls are for the lift/lower and chassis leg opening/closing functions. Direction arrows adjacent to the buttons indicate each function (see Fig. 2). If pressure is released from any button during use, the powered movement will stop immediately. Automatic Cutout: (not an operator control but a function built into the lift electronics): If the lift is inadvertently overloaded (by trying to lift a patient that is too heavy), an automatic cutout function operates to prevent the lift from raising a weight in excess of one and a half times the maximum rated load. This will stop the lift motion automatically. If this occurs, release the pressure from the control handset button or control panel switch immediately. The electronics will reset so that the patient can only be lowered when either of the Lower buttons is pressed. Remove the patient from the lift. Automatic Stop Function: Great care should be taken not to lower the patient support arms onto the patient or any other obstruction. If this should happen, the motor will continue to run but downward movement will be blocked by the obstruction. If this occurs, release pressure from the lower button immediately and operate the raise button until the lift is clear. Then remove the obstruction. Raise button Lower button P1396a Chassis legs open button Chassis legs close button Fig. 2 Stop Button (red) (see Fig. 1): If you have to immediately stop any powered movement, (other than by releasing pressure on the button on the control handset), press the red stop button located on the control panel above the battery. This function can also be used to ensure that powered operation cannot accidently start when either transporting the lift, or leaving it in storage or unattended. Once the red Stop Button has been pushed, the green reset button will have to be reset before the Sara 3000 can be operated again. 7
8 Product Description/Function System failure lower override: This can be used in the event of main control failure. If the control handset fails to operate the lift with a patient still supported by the sling, a provision for lowering has been made using the lower override knob located on the right hand side of the motor/actuator (see Fig. 3). To operate the lower override, pull the knob upward. To halt lowering, release the knob. Only use the knob if there is a normal control failure. Do not use it for normal function lowering. Chassis Castor Brakes: The chassis rear castors have brakes which can be foot operated if required (see Fig. 4), such as when leaving a patient unattended, or to keep the Sara 3000 in position. P1341a, b Caution: Before operating the lower override to lower a patient, always ensure that a chair or suitable support is underneath ready to accept the patient. Fig. 4 Fig. 3 The lower override will operate whether or not the emergency stop button has been pressed. Battery Discharge Indicator: This is a small LED display, located on the battery pack holder, which shows the charge condition of the lift battery (see Fig. 1). Hour Meter: This is a small LCD display which shows the total duration of powered operation (in hours see Fig. 1). This is primarily intended as an aid to service engineers and to help the attendant calculate maintenance intervals. Foot Support: For positioning the patient s feet when lifting and transporting. Lower Leg Straps: Accessory used to ensure that the lower parts of the patient s legs stay close to the knee support. They pass around the knee supports, then around the patient s lower calves. To fasten, overlap and press the ends together. Ensure that the straps are firm but comfortable for the patient. Adustable Width Chassis Legs: To open the chassis legs to any variable width, press the appropriate button on the control handset. When pressure is released from the button, movement will stop and the chassis legs will remain securely in position. Note: The lift should be transported with the chassis legs closed, as this will be easier to maneuver through doorways, etc. Warning: The patient and/or operator should never place their feet or any other part of their body in the area between the foot support and chassis legs when the chassis legs are closing. 8
9 Using Your Sara 3000 Using the Sara 3000 for Toileting and Transporting Before approaching the patient, the attendant should always tell the patient what they are going to do, and have the correct size sling ready. Although a patient can be put into the sling with the Sara 3000 close by, it may be easier to do so with the Sara 3000 moved away. Once the sling has been fitted (see the following sections), the Sara 3000 may be brought close to the patient as follows: Adjust the height of the Patient Support arms to avoid approaching the patient at eye level. Make allowances for the patient s arms and any obstructions, such as chair arms, etc. Approach the patient from the front with the lift. Stop before the foot support and knee support come in contact with the patient. (See Fig. 5). When the patient is ready, help or allow the patient to place his/her feet on the foot support. Push the Sara 3000 toward the patient to easily assist with this. (See Fig. 6). Fig. 6 Carefully push the lift in closer to make full lower leg contact with the knee support. Fig. 5 Note: Press the appropriate button on the control handset if the chassis legs need to be opened to go around the chair. 9
10 Using Your Sara 3000 Standing Sling Caution: An assessment must be made as to whether the patient requires the lower leg straps. Apply these if necessary. Use if necessary. Encourage the patient to lean forward slightly to enable the sling to be placed around his/her lower back (see Fig. 7). Position the sling around the patient s back so that the bottom of the sling lies horizontally about two inches above the patient s waistline, with the patient s arms outside the sling. Ensure that the support strap is separated and brought loosely around the body, and is not twisted or trapped behind the patient s back. Fig. 8 If the Sara 3000 is not already close to the patient, bring it to the patient as described previously. Apply the clips to the attachment points, and secure them for safety. Fig. 7 To fasten the support strap securely, press the buckles together. The strap should be tight, but comfortable for the patient. Note: As stated previously, the comfort sling may be applied before the Sara 3000 is brought into position, as shown in Fig. 6. Fig. 9 Note: The patient should be supported by the sling, but not pulled forward too much. Caution: The support strap must always be applied when using the sling. Note: The support strap will help to support the patient in the sling during the lifting procedure. The strap also retains the sling in the correct position around the patient. 10
11 Using Your Sara 3000 Fig. 10 If possible, the patient should then hold on to the Patient Support grips with one or both hands. The patient is then ready to be lifted. Note: If the control handset button is released during the lifting or lowering procedure, powered motion will stop immediately. If the patient is able to offer some assistance to stand, this may be beneficial for patient confidence and muscular exercise. Encourage the patient to give as much assistance as possible to raise from the chair and/or steady themselves. Use the lift button on the control handset to raise the patient to a suitable and comfortable height for the particular function. (See Fig. 11). Fig. 11 Caution: The patient s feet should always remain in full contact with the foot support. When lifting, check to ensure that the patient s feet do not lift from the the support or floor. If this should happen, lower the patient immediately until his/ her feet fully reach the support or floor. 11
12 Using Your Sara 3000 IMPORTANT: Always check that the sling adjustment clips are locked into position before and during the lifting cycle, and in tension as the patient s weight is gradually taken up. Note: If patients can stand sufficiently well and lock their knees in the normal way when fully raised, their knees will come away from the Proactive Pad and they will be able to lean back into the sling. Patients who can only hold on with one hand, such as those who have suffered a stroke, may still be lifted with the Sara 3000, but their disabled arm should be held down in front of the body during the lift by the attendant (or a second attendant), while their functioning hand holds the patient support arm in the normal way. To remove the sling when the patient is seated in the new position. Open the buckle to remove the support strap. Warning: Do not attempt to release the support strap while the patient is supported by the sling. Caution: If the patient lacks sitting balance and has been returned to sit on the side of the bed, a second attendant may be needed to support the patient while the sling is being removed. Caution: Only use this or other methods after a satisfactory professional assessment has been carried out on the individual patient. Transfer the patient to the required position, such as the toilet, wheelchair, chair, bed, etc. Note: Transportation should be performed with the chassis legs closed, as this will be easier when maneuvering through doorways, etc. While the patient is raised, make any necessary adjustments to clothing, incontinence pads, etc., before lowering again. Use the control handset to carefully lower the patient. Caution: Apply the chassis brakes if leaving the patient at the toilet, or if leaving the patient unattended. 12
13 Battery Charging The Sara 3000 uses a battery discharge indicator, located on the cover above the battery. (See Fig. 1). It is recommended that the battery be removed from the lift and recharged when the battery discharge indicator displays amber. To prolong the battery pack life, recharge it before it reaches a low state of battery charge, and certainly before it is totally discharged. Your lift is equipped with an audible warning device which will sound when the battery discharge indicator reaches the red light range. To ensure that the Sara 3000 is always ready for use, it is recommended that a fully charged battery pack always be available. Do this by having additional battery packs available and keeping one charging while the other is in use. It may be considered good protocol to have a fully charged battery ready for the start of every work shift. Note: When a fully charged battery is inserted into the lift the display will return to the green fully charged position, regardless of the level the indicator had reached previously. However, if a partially charged battery is inserted, the previous indicator level will be maintained, even though the recently inserted battery may be in a better state of charge than indicated. To achieve a true indication of battery condition, a fully charged battery must be inserted into the lift. This will reset the indicator. Place the battery pack on the charger as follows: Place the battery pack on the charger as follows: Insert the battery pack into the charger unit in a manner similar to installing it in the Sara 3000 and push it firmly in. The charging connector will automatically couple. Then switch on the power. A green light and an orange light will then be displayed. The green light indicates that the power is connected, and will stay on until the main power is disconnected. The orange light indicates the battery condition and will go out when the battery pack is fully charged (see Fig. 13). Green Light Charger Unit Orange Light P1184e/2 Fig. 12 P1189b Warning: Ensure that the electric power to the charger unit is switched off before connecting the battery. Note: The cable that connects the power supply to the charger is supplied as a separate item. If using the battery charger for the first time, or if the cable has been unplugged from the charger, connect the cable fully into the charger before connecting to the main electrical socket. When the LEDs on the battery discharge indicator display amber, complete the lift/lower cycle. Then take the lift to a convenient location and remove the battery pack by holding it securely, depressing the button at the top of the battery pack then pulling it out carefully. Fig. 13 A discharged battery should be left approximately 8 hours to totally recharge. Caution: Hold the pack firmly to ensure that it does not drop and become damaged or cause personal injury. Note: The battery pack may be left connected to the charger unit when it is fully charged without being damaged. 13
14 Battery Charging When the battery pack is fully charged, disconnect the power, remove the pack from the charger, and insert it back into the Sara An electrical connection is made automatically. Ensure the green Reset Button is pressed in. The Sara 3000 is now ready for use. Warnings Warning: Always disconnect the main supply before disconnecting the battery from the charger unit. Warning: Never charge the battery near a patient environment. The charger is for indoor use only. Only use the charger unit in a dry environment. Do not use it in a bathroom. Do not expose the charger unit or battery pack to rain or spray and do not soak it. Do not expose the charger unit to dust. Do not cover the charger while in use, as it can overheat. Do not smoke or allow open flames in the vicinity of the battery. The battery charger is for use only with batteries that are supplied by ARJO for use with the Sara Use the battery chager for sealed lead acid batteries only. Under no circumstances should the charger be used to recharge nonrechargeable batteries. Do not attempt to open or tamper with the charger in any way. Send the charger to the manufacturer for any repairs. The power socket must be easily accessible. If a fault condition occurs, switch off the power and remove the connection plug from the socket. When charging batteries, only use ARJO components that have been specifically designed for this purpose. General Battery Safety Practices Warning: Only use the ARJO battery that is supplied for use with the Sara Only use the ARJO charger unit supplied with the Sara Do NOT charge batteries in a sealed container. Do NOT place batteries near or dispose of them in a fire. Do NOT short-circuit a battery. Do NOT store batteries at temperatures in excess of 60 C (140 F). Do NOT crush, puncture, open, dismantle or otherwise mechanically interfere with batteries. Warning: If the battery casing becomes cracked, and electrolyte comes into contact with skin or clothing, wash immediately with water. If the electrolyte contacts the eyes, wash them immediately with copious amounts of water and seek medical attention. When disposing of batteries, contact the appropriate local authority for advice. The abbreviation Pb shown adjacent to the recycling and trash bin symbols on the battery pack label is the element symbol for lead. It indicates that the battery contains lead and should therefore not be disposed of in the normal manner but must be recycled. Note: If the lift is not going to be used for an extended period of time, remove the batteries. 14
15 Care of Your Sara 3000 General Lift Care Caution: All slings should be checked, and, if necessary, washed according to instructions on the sling. Slings should not be classified as linen, but as an accessory to a patient transfer lift and, therefore, are classified as a medical device. Slings should be cleaned and disinfected only in strict accordance with the manufacturer s instructions. Mechanical pressure, such as rolling or pressing, should be avoided during the washing and drying procedure as this can damage parts that are vital to the safe and comfortable operation of the sling. Washing and drying temperatures must not exceed 80 C (176 F). Wash using normal detergents. Do not iron. It is recommended that ARJO Patient lifts, equipment, accessories and slings are regularly cleaned. If the slings, lift and equipment need cleaning, or you suspect them of being contaminated, follow the cleaning and/or disinfection procedures recommended below before re-using the equipment. This is especially important when using the same equipment for another patient, to minimize the risk of cross-infection. To clean the lift, wipe it down with a damp cloth using warm water to which an appropriate ARJO disinfectant cleaner has been added, such as ARJO Clean. Note: These products are available from ARJO or its authorized distributors. Caution: Do not soak the product as this could damage electrical components and cause internal corrosion. If a hot air dryer is used to dry the lift, the temperature should not exceed 80ºC (176ºF). Do not use petroleum-based solvents, as these may damage plastic parts. To disinfect contaminated lifts and accessories, use the preferred method of wiping the product completely with hard surface disinfectant wipes which are supplied impregnated with a 70% v/v solution of Isopropyl Alcohol. Note: A rubbing action will be necessary when using the wipes, to effectively disinfect the surfaces. IMPORTANT: Cleaning and disinfection products must be used in accordance with the manufacturer s instructions. Wear the appropriate eye, hand and clothing protection at all times when handling disinfectants. Note: 70% v/v Isopropyl Alcohol wipes have been proved to be effective against MRSA and several other microorganisms under light soiling conditions. Ensure that the battery pack is always fully charged. Environmental Advice When disposing of any items associated with the lift, contact the appropriate local authority for advice. 15
16 Care of Your Sara 3000 Check that the lift can be moved normally, and ensure that the castors move freely, as they can be clogged by hair and fluff. Also make sure that the tread of the castor is not damaged. Caution: Ensure that the castors are firmly secured to the chassis. Carefully inspect all parts, in particular where there is personal contact with the patient s body. Ensure that no cracks or sharp edges have developed which could injure the patient s skin or become unhygienic. It is essential that the clips and slings are carefully inspected before each and every use. If the slings are frayed, or the clips are damaged, do not use the sling and replace it immediately. Check that all external fittings are secure and that all screws and nuts are tight. Ensure that all the instruction labels are firmly attached and in a readable condition. Periodic Testing For normal operation - use the control handset to raise and lower the Patient Support. This is to test for full and efficient movement. Automatic Stop Function: With the Patient Support arms raised well above their lowest position, use the control handset to lower them and, at the same time, with your other hand, hold the Patient Support arms up briefly. The motor will continue to run while the Patient Support arms weight is held. This is quite normal. Release the button and carefully lower the Patient Support Arms. Use the Lower button on the control panel to repeat this check. This is to accurately check that the automatic stop functions. Stop Button (red): To test the Emergency Stop function, use the control handset to lift or lower the Patient Support arms. While using the handset, press the red Stop button. Powered movement should stop immediately. Repeat this check for the chassis leg opening/ closing function, and reset the button. Adjustable Width Chassis Function: Use the control handset to open and close the chassis legs to check for full and efficient movement. General Lift Condition: Carry out a general visual inspection of all external parts, and test all functions for correct operation, to ensure that no damage has occurred during use. Caution: If in doubt about the correct operation of the Sara 3000, do not use it and contact the ARJO Service Department. Servicing Advice Warning: ARJO recommends that the Sara 3000 be maintained at regular intervals. See Sara 3000 Preventive Maintenance Schedule (ARJO Literature Part No. KKX81011.US/Sara 3000). With regular use, the following items are subject to wear: slings, batteries, straps, castors. These items must be regularly checked as described previously, and replaced as needed. Warning: UK LIFTS ONLY: Important legislation came into force on 5th December 1998, which has an impact on the schedule of service for your patient lift(s), variable height baths and other raising and lowering equipment. The Lifting Operations and Lifting Equipment Regulations (LOLER) 1998 and The Provision and Use of Work Equipment Regulations (PUWER 98) must be satisfied by the owner. A schedule of thorough examinations every six months has been developed to comply with the law and details can be obtained from ARJO Service UK. Parts lists and circuit diagrams are available on request from ARJO or its approved distributors. Warning: Spare parts, if required, are available from ARJO or its approved distributors. Special tools are required for certain component replacement. Warning: The simplest, safest and most effective way to maintain your product is to have it methodically and professionally serviced by an ARJO approved representative using ARJO approved spare parts. For information on service and maintenance contracts, please contact your local ARJO distributor. 16
17 Labels Fig Product Name 2. Safe Working Load kg (350 lb) 3. Battery Information 4. Emergency Stop and Reset Button Identification 5. Battery Discharge Indicator and Hour Meter 6. ARJO logo 7. Attention: Read Operating Instructions 17
18 Technical Specification Component Weights kg lbs Sara 3000 complete (134) Battery Pack (8.4) Maximum Lifting Capacities Basic Lift (350) All slings (350) Electrical Battery Type... (Rechargable - sealed lead acid) Battery Part Number... NDA Battery capacity... 24V 4Ah Lift - Protection Class... IPX4 Lift nominal voltage... 24V Fuse - Overload... 5A (thermal cutout) Fuse - PCB... 10A (time delay) Battery Charger Part Number (suffix is country code)... NDA2100-EU... NDA2100-GB... NDA2100-CH... NDA2100-US... NDA2100-AU Medical Equipment:- type protection against electrical shock in accordance with IEC 601-1) ARJO Patient Handling products meet the requirements of Electromagnetic Compatibility (EMC) as stated in clause 12.5 of the Medical Devices Directive 93/42/EEC. Although compliant with EMC requirements, there is a remote chance that close proximity usage may affect overly sensitive electrical equipment Duty cycle Max volts Max amps Mast Lift Actuator... 10% - 6 min/hr 24 5 V Chassis Actuator... 10% - (6 min/hr) 24 1 Environment Air Humidity/Storage C (68 F) Usage temperature range (ambient) C (41 F) to +35 C (95 F) Optimum Usage Temperature (ambient) C (68 F) to +25 C (77 F) Storage and transportation temperature (ambient) C (14 F) to +45 C (113 F) Maximum sound power level In accordance with ISO dB (db re 1pW ± 3dB) 18
19 Technical Specification Total Length (A) : 1,000 mm Min.Working Height (B) : 930 mm Max. Working Height (C) : 1,730 mm Height Chassis (E) : 115 mm External Width, legs closed (F) : 650 mm Internal Width, legs open (G) : 900 mm Total Height (D) : 1,185 mm Weight : 61 kg (134 lbs) Technical specifications may be revised and changed without prior notice. Fig
20 AUSTRALIA ARJO Hospital Equipment Pty. Ltd. 154 Lytton Road Bulimba Brisbane QLD, 4171 Tel. (61) Fax. (61) SVERIGE ARJO SCANDINAVIA AB Box 61, Eslöv Tel Fax E-post: [email protected] DANMARK ARJO SCANDINAVIA Postboks 51, 4632 Bjæverskov Tel Fax E-post: [email protected] Internet: NORGE ARJO SCANDINAVIA Enebakkveien 117 d, 0680 Oslo Tel Fax E-post: [email protected] Internet: BELGIQUE / BELGIË ARJO Hospital Equipment nv/sa Ternesselei Wommelgem Belgium Tel Fax [email protected] CANADA ARJO Canada Inc South Gateway Road Unit C Mississauga, ONTARIO L4W 5J1 Tel Fax CESKÁ REPUBLIKA ARJO Hospital Equipment s.r.o. Strmá 35 CZ BRNO Tel Fax DEUTSCHLAND ARJO Systeme für Rehabilitation GmbH Christof-Ruthof-Weg Mainz-Kastel Tel.: Fax: [email protected] ESPAÑA ARJO SPAIN, S.A. C/ San Rafael, nº ALCOBENDAS (MADRID) SPAIN Tel Fax FRANCE ARJO Equipements Hospitaliers sa 45 Avenue de l'europe Eurocit BP Roncq Cedex Tél Fax [email protected] GREAT BRITAIN ARJO St. Catherine Street Gloucester, GL1 2SL ENGLAND U.K. Tel. (08702) Fax. (01452) HONG KONG ARJO Far East Ltd APEC Plaza, 49 Hoi Yuen Road, Kwun Tong, Kowloon, HONG KONG Tel Fax ITALIA ARJO Italia S.p.A. Via Poggio Verde, ROMA Tel Fax [email protected] NEDERLAND ARJO NEDERLAND B.V. De Blomboogerd BX TIEL Postbus HC TIEL Tel Fax [email protected] ÖSTERREICH ARJO GmbH Föhrenweg 5 A-6065 THAUR Tel Fax ARJO Poland Sp. z o.o. ul. Lirowa Warsaw Poland Tel./fax office: Tel./fax service: SCHWEIZ / SVIZZERA ARJO-Sic AG Florenzstrasse 1d Postfach Basel SCHWEIZ Tél Fax [email protected] USA ARJO, Inc. 50 North Gary Avenue Roselle, IL Tel Fax ARJO(2756) Printed in Great Britain. If your country is not listed here, please contact your local distributor, or ARJO International, Florenzstrasse 1d, Postfach Basel, SWITZERLAND. Tel Fax ARJO Med. AB LTD FM ISO 9001 IS ARJO GLOUCESTER U.K.
SARA 3000TM Parts list KKX81208-00-M issue 3 March 2008
SARA 3000 TM Parts list KKX81208-00-M issue 3 March 2008 Introduction ArjoHuntleigh ArjoHuntleigh products are patented or patent pending. Patent information is available by contacting ArjoHuntleigh. The
SARA PLUS THE ADVANCED STANDING AND RAISING AID
SARA PLUS THE ADVANCED STANDING AND RAISING AID OPERATING AND PRODUCT CARE INSTRUCTIONS KKX52180M-EN Issue 2 October 2006 ARJO ARJO products are patented or patent pending. Patent information is available
Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Vax model number: Version 1.0
VRS5W Powermax User Guide V1.0.qxd:V1.0 23/7/10 15:35 Page 1 Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308 Carpet Washer Vax model number: VRS5W instruction manual Version 1.0 Please read carefully
Instruction Manual. Window Wiper AFW900. (Read carefully before use)
Instruction Manual Window Wiper AFW900 (Read carefully before use) When using electrical appliances, basic precautions should always be followed, including the fact READ ALL INSTRUCTIONS IN THIS MANUAL
OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle
OWNER S MANUAL US Permolock C3 Docking system for Power wheelchair in vehicle How to contact Permobil Head Office of the Permobil group Permolock C3 Docking system for electric wheelchair in vehicle Produced
Contact Details. Please note that some of the contact details on this PDF document may not be current.
Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: [email protected]
- 2 - IMPORTANT SAFETY REMINDERS
USER MANUAL IMPORTANT SAFETY REMINDERS This appliance should only be used for domestic cleaning, as described in this user guide. Please ensure that this guide is fully understood before operating the
GoFit Platinum Power Vibe
GoFit Platinum Power Vibe GFVT011 GoFit Platinum Pty Ltd Phone 1800 446 348 fax 1300 446 348 www.gofit.com.au IMPORTANT PRECAUTIONS When using an electrical appliance, the basic following precautions
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.
Battery-Powered Mower NEUTON 24-Volt Charger Instructions Booklet Dear Neuton Owner, In order for you to get the most out of your Neuton Mower, we recently reviewed and revised our battery-charging instructions.
Luna/200. Luna/275. Ceiling hoist. User instruction. Important - warning. This manual must be read before the Luna is used
Luna/200 Luna/275 Ceiling hoist User instruction! Important - warning This manual must be read before the Luna is used This manual is intended for technicians, installers, therapists and other personnel,
TT TOYS TOYS - OWNER S MANUAL. We are delighted that you have decided to purchase this TT Toys Toys children s car.
TT TOYS TOYS - OWNER S MANUAL We are delighted that you have decided to purchase this TT Toys Toys children s car. This owner s manual contains important information for the safe assembly, handling and
IMPORTANT SAFETY RULES TO FOLLOW
WARNING FLOOR & CARPET CLEANER Any piece of equipment can be dangerous if not operated properly. YOU are responsible for the safe operation of this equipment. The operator must carefully read and follow
Li Battery Pack & Charger Safety & Operating Instructions
Li Battery Pack & Charger Safety & Operating Instructions NEUTON Power Equipment 75 Meigs Road Vergennes, VT 05491 Toll-Free phone: 1-866-NEUTON1 (638-8661) Fax: 1-802-877-1213 Website: www.neutonpower.com
OPERATING INSTRUCTIONS AQUAJOY PREMIER PLUS AND AQUAJOY JUNIOR PLUS
OPERATING INSTRUCTIONS AQUAJOY PREMIER PLUS AND AQUAJOY JUNIOR PLUS First point of contact is always as follows unless supplied by a Local Authority or Dealer. AQUAJOY BATHLIFTS LTD CONSETT BUSINESS PARK
Max load: 450/625lbs, 205/285kg
Rise450/625M 450/625T Manual Max load: 450/625lbs, 205/285kg The ceiling track lift Rise 450/625 has been developed for use in combination with the correct lifting accessories for convenient and trouble-free
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.
ZAPPY 3 OWNER S MANUAL Read this manual completely before riding your Electric ZAPPY 3. TECHNICAL INFORMATION Model No. : ZAPPY 3 Product size Type of motor Motor power Battery type Battery Charger Charging
DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd. 2012 Dream Swing - 1 -
DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd. 2012 Dream Swing - 1 - DREAM SWING THESE INSTRUCTIONS ARE IMPORTANT. PLEASE READ CAREFULLY AND RETAIN FOR FUTURE REFERENCE. Read the entire instruction before
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
400 Amp Rechargeable Jump Start System RAC-HP082
400 Amp Rechargeable Jump Start System RAC-HP082 MAINTENANCE Always inspect the tool before use to ensure the cables are in good condition and the clamps are clean and free from corrosion. Keep clean by
VACUUM CLEANER INSTRUCTION MANUAL
VACUUM CLEANER INSTRUCTION MANUAL MODEL: SVC9702 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING AND KEEP IT PROPERLY FOR FUTURE USE 1 Safety Cautions: WARNING: To reduce the risk of fire, electrical shock,
Magnetek MLTX, SLTX and Pendant Battery Charger. Instruction Manual. NiMH Battery Charger (Smart Charger) For use in:
Magnetek MLTX, SLTX and Pendant Battery Charger NiMH Battery Charger (Smart Charger) Instruction Manual For use in: E10670, E10757 and E10759 Battery Charger Assemblies October 2011 Part Number: 178-00204-1000_R00
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase
User s Guide Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase of the FLAVORCHEF cooking system, which will provide you with healthy and tasty meals for
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK
FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992
ELECTRIC BICYCLE OWNER S MANUAL
ELECTRIC BICYCLE OWNER S MANUAL For Owners of EG Athens 250 Electric Bicycle Table of Contents Descriptions: Page Installation Instructions 2 How to install the bicycle out of the box 2 Operation Instructions
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
15GAL STEEL OIL DRAIN WITH 110V PUMP
15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
EVAPORATIVE AIR COOLER INSTRUCTION MANUAL
EVAPORATIVE AIR COOLER INSTRUCTION MANUAL Model: SF-614P Please read this manual thoroughly before using this product. Keep in a safe place for future reference. CONTENTS A. PRODUCT INTRODUCTION 2 B. TECHNICAL
User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. White series
C88-VW-B UG [Update 10.05.12]_User guide 10/05/2012 09:40 Page 1 User Guide Vax Careline: (UK) 0844 412 8455 Bagless Cylinder White Get Cleaning... What s your Vax model number? (Located on the top flap
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly
DIMENSION ELECTRIC RANGE
DIMENSION ELECTRIC RANGE DREAM DIMENSION PETRUS DIMENSION 08/52282/0 (UK) Issue 2 The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility
CHILD BOOSTER SEAT. Instructions for Installation & Use Series No. 4050/A/2013 IMPORTANT: KEEP THIS BOOK IN THE PLACE PROVIDED ON THE CHILD RESTRAINT
CHILD BOOSTER SEAT Instructions for Installation & Use Series No. 4050/A/2013 IMPORTANT: KEEP THIS BOOK IN THE PLACE PROVIDED ON THE CHILD RESTRAINT INDEX PAGE 3 4 6 7 9 10 14 19 21 22 INTRODUCTION WARNINGS
Patient Slings. Owner s Operator and Maintenance Manual. DEALER: This manual must be given to the user of the product.
Owner s Operator and Maintenance Manual Patient Slings DEALER: This manual must be given to the user of the product. USER: BEFORE using this product, read this manual and save for future reference. For
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
Uno 102. Product Description. Instruction Guide
Uno 102 Instruction Guide English 7EN150104-04 2013-08-22 Applies to the following models: Uno 102 EE Prod. No. 2010004 Product Description Uno 102 is a mobile lift with electric raising and lowering of
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1
REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com
ELECTRIC BICYCLE OWNER S MANUAL
ELECTRIC BICYCLE OWNER S MANUAL For Owners of EG Bali 500EX and EG Milan 500EX Electric Bicycle Table of Contents Descriptions: Page Installation Instructions 2 How to install the bicycle out of the box
Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger
Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger The Nucleus Freedom BTE Rechargeable Battery (A25) is designed for use with your Nucleus Freedom BTE Controller (3 Zinc
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
User s Manual XXL Care Lift, Electrically Elevating Shower-, Commode- & Care Lift with Tilt-in-Space Seat Unit
User s Manual XXL Care Lift, Electrically Elevating Shower-, Commode- & Care Lift with Tilt-in-Space Seat Unit 12B99, UK Rev 4, 2015. 09 User s Manual XXL Care Lift, Electrically Elevating Shower-, Commode-
Operations Manual Blast Chiller
Operations Manual Blast Chiller ADE- 2039-A Page 1 of 14 Contents Page 1 What is the Adande System 3 2 Adande Technology Explained 3 3 EC Declaration of Conformity 4 4 Storage of Product 5 5 Operating
TOOLS, LUBRICATION, SEALANTS AND LOCKINGS
TOOLS, LUBRICATION, SEALANTS AND LOCKINGS Reference Copy For internal use only! 09.NE.00/2GB September 2002 Reference Copy Arjo Hospital Equipment AB 2002 Arjo products are patented or patent pending.
FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions
FJ2 2 Ton Trolley Floor Jack Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.
RESTWELL RISE & RECLINE ARMCHAIRS BORG - OWNER S HANDBOOK PARTS DESCRIPTION
RESTWELL RISE & RECLINE ARMCHAIRS BORG - OWNER S HANDBOOK CONTENTS 1. Introduction 2. Model Description 3. Parts Description 4. Personal Safety 5. Installation Instructions 6. Backrest Removal 7. Operating
19 LED Tube Controller ORDERCODE 41003
19 LED Tube Controller ORDERCODE 41003 Congratulations! You have bought a great, innovative product from Showtec. The Showtec 19 LED Tube Controller brings excitement to any venue. Whether you want simple
SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair
SERVICE MANUAL US Corpus 3G Seat system for electric wheelchair How to contact Permobil Head Office of the Permobil group Produced and published by Permobil AB, Sweden Version 4, 2014-07 Item No.: 205260-US-0
REARWARD- & FORWARD-FACING USER MANUAL ECE R44 04. GROUP WEIGHT AGE 0+/1 0-18 kg 6m-4y
REARWARD- & FORWARD-FACING USER MANUAL ECE R44 04 GROUP WEIGHT AGE 0+/1 0-18 kg 6m-4y 1 Thank you for choosing BeSafe izi Combi ISOfix. BeSafe has developed this seat with much care, to protect your child
harbor cub Electric Remote Control Airplane Model 92906 assembly & Operating Instructions
harbor cub Electric Remote Control Airplane Model 92906 assembly & Operating Instructions IMPORTANT: If damage is caused due to a crash, your warranty is void. Visit our website at: http://www.harborfreight.com
ELECTRIC BICYCLE USER MANUAL
ELECTRIC BICYCLE USER MANUAL 1 Main Technical Parameters and Specification Weight: 23 kg Wheel size: 20 Maximum speed: 25 km/h E BIKE URBAN Range: Up to 45km (with pedal assist) Type: lithium Voltage:
Battery charger. Art.no Model 18-2692 CB5-5L-BS1 ENGLISH SVENSKA NORSK SUOMI. Ver. 201209 Original instructions
Important! Read the entire instruction manual carefully and make sure that you fully understand it before you use the equipment. Keep the manual for future reference. ENGLISH Battery charger SVENSKA SUOMI
UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video
UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video http://bit.ly/9ywwh! CAUTION MAKE SURE NO OBSTACLES ARE IN THE DESK S PATH AND ALL
Vacuum Hair Clipper. 10,000 prize draw. Register online for HC6550. EXTRA year guarantee FREE rewards gallery
Vacuum Hair Clipper HC6550 Register online for 10,000 prize draw EXTRA year guarantee FREE rewards gallery Visit www.remington.co.uk/productregister You must register within 28 days of purchase. Thank
Get Cleaning... User Guide Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Multifunction. vax.co.uk. 6131 Series. What s your Vax model number?
6131 Series User Guide v1.1-06.09.10:user guide 09/09/2010 11:42 Page 1 User Guide Vax Careline: (UK) 0844 412 8455 Multifunction Get Cleaning... What s your Vax model number? 6 1 3 1 What s your serial
1000-LB. TRAILER JACK OWNER S MANUAL
1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
POP Pushchair. Instructions
POP Pushchair Instructions Important: Keep for future reference Please read these instructions carefully before using your new pushchair Keep them in a safe place so that you may use them in the future
Operating instructions in the back. www.blackanddecker.co.uk PD1020L
Operating instructions in the back www.blackanddecker.co.uk PD1020L 2 ENGLISH (Original instructions) Intended use Your Black & Decker Dustbuster handheld vacuum cleaner has been designed for vacuum cleaning
Digital Photo Picture Frame. Operation Manual
Digital Photo Picture Frame Operation Manual 20070309 CONGRATULATIONS on your purchase of a Polaroid 7 LCD Digital Photo Picture Frame. Please read carefully and follow all warnings and instructions in
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
HAIR CLIPPER. Model No. HC5150 HC5150 2. 3.
All technical modifications reserved. 09/08. TSC 08.0634 HAIR CLIPPER 2. 3. 1. Model No. HC5150 4. 10/UK/HC5150 Version 03/10 Part No. T22-29458 REMINGTON is a Registered Trade Mark of Spectrum Brands,
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
Operating instructions Cordless K 10253 impact wrench
Operating instructions Cordless K 10253 impact wrench Operational precautions General safety instructions warning! 1. Consider work area environment. Do not expose tools to rain. Do not use tools in damp
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
User manual. Videomatic VERDE MF
User manual Videomatic VERDE MF EN Contents Product information.......................................... 6 I. General information....................................... 6 Notes on the electromagnetic
MIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar
Wolflite Safety Handlamp H-251E
Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
Operating instructions. SCORP 220 Plus SCORP 360. Pipe Cutter. Code 790 014 762 Machine-no.:
precision. power. simplicity. Operating instructions Pipe Cutter SCORP 220 Plus SCORP 360 Code 790 014 762 Machine-no.: All rights reserved, in particular the rights of duplication and distribution as
National- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
CAR SEAT/ STROLLER INSTRUCTION MANUAL
CAR SEAT/ STROLLER INSTRUCTION MANUAL English PM-0624AB 3/98 Do not use this 4-in-1 System until you read and understand these instructions! IMPORTANT INFORMATION Thank you for selecting this 4-in-1 System
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
Dual Cushion User Manual. Specialist Suppliers to the Healthcare Industry
Dual Cushion User Manual Specialist Suppliers to the Healthcare Industry Thank you for purchasing this Shelden Healthcare pressure relieving cushion system. PLEASE READ THIS USER MANUAL CAREFULLY BEFORE
Model UT201/202: OPERATING MANUAL. Table of Contents
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness
BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.
BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1 UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping
CompacVideo Otoscope. Model 23120 (NTSC) and 23120P (PAL) Operating Instruction Manual
CompacVideo Otoscope Model 23120 (NTSC) and 23120P (PAL) Operating Instruction Manual Thank you for purchasing the Welch Allyn CompacVideo Otoscope System for ear care professionals. The operating and
Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE
Portable Evaporative Air Cooler for Indoor Use OWNER S MANUAL Read and save these instructions before use Model: CL25AE Power rating: 230 Watts Voltage rating: 120 Volt AC, 60Hz For product inquiries or
Model UT33A: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons LCD Display Measurement Operation
SIBIR MANUAL V110 KE. English page 5 RKE - 1D 822 70 66-02
SIBIR MANUAL RKE - 1D V110 KE English page 5 822 70 66-02 2 1 A. Flue tube E. Adapter I. Thermostat B. Flue baffle F. Burner base J. Lever arm C. Control knob G. Lamp glass D. Fuel gauge H. Lamp glass
CappController Pipette Controller. Operation Manual Version: 1.2. www.capp.dk
CappController Pipette Controller Operation Manual Version: 1.2 www.capp.dk skal vises her. Table of Content 1. Safety Precautions... 1 2. General Description... 2 3. Getting Started... 4 3.1. Recharging
Sport Ice Elektro 124
Sport Ice Elektro 124 Operation Manual 2007/4 V2.1 Introduction The Sport Ice Elektro 124 is an ice resurfacing machine designed to be used on small ice surfaces. The machine has been designed to produce
3000W Power Inverter
3000W Power Inverter OWNER S MANUAL Model number-4573000 TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions
SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important
MAXI MOVE A MOBILE PASSIVE LIFTER FOR DEMANDING CARE ENVIRONMENTS. ...with people in mind
MAXI MOVE A MOBILE PASSIVE LIFTER FOR DEMANDING CARE ENVIRONMENTS...with people in mind 2 Maxi Move A PROVEN ASSET FOR ALL CARE ENVIRONMENTS Maxi Move, the most complete mobile lifter system available,
Nokia Bluetooth Headset BH-800 User Guide. 9246974 Issue 2
Nokia Bluetooth Headset BH-800 User Guide 9246974 Issue 2 DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product HS-24W is in conformity with the provisions
MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions
06/2011 MBSAW Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper
Thank you for your recent purchase of the Exerciser 2000. Exerciser 2000 Elite Platinum Series. Own e r s Ma n u a l
Exerciser 2000 Elite Platinum Series Own e r s Ma n u a l LED Timer Thank you for your recent purchase of the Exerciser 2000 Elite MultiSpeed. The Exerciser 2000 Elite is ETL approved, which insures you
IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS. For use with a Power Wheels vehicle that requires a 12-Volt 9.5 Amp/Hr lead acid battery.
74777 12-Volt 9.5 Amp/Hr Battery IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS. For use with a Power Wheels vehicle that requires a 12-Volt 9.5 Amp/Hr lead acid battery. WARNING ELECTRICAL HAZARD
