Operating Instructions & User s Information Manual VITODENS 200 WARNING. IMPORTANT Read and save these instructions for future reference.
|
|
|
- Simon Williamson
- 9 years ago
- Views:
Transcription
1 Operating Instructions & User s Information Manual Please file in Service Binder Vitodens 200 WB2 Series Wall-mounted, gas-fired condensing boiler For natural gas and liquid propane Heating input NG 25 to 230 MBH 7 to 67 kw Heating input LP 25 to 214 MBH 7 to 63 kw VITODENS 200 WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable liquids in the vicinity of this or any other appliance. IMPORTANT Read and save these instructions for future reference. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliances. Do not touch any electrical switches, do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING Improper installation, adjustment, and/or operation could cause carbon monoxide poisoning resulting in injury or loss of life. This product must be installed and serviced by a professional service technician who is experienced and qualified in hot water boiler installation and gas combustion. 07/2007
2 Safety, Installation and Warranty Requirements Safety, Installation and Warranty Requirements Please ensure that these instructions are read and understood before commencing installation. Failure to comply with the instructions listed below and details printed in this manual can cause product/property damage, severe personal injury, and/or loss of life. Ensure all requirements below are understood and fulfilled (including detailed information found in manual subsections). H Licensed professional heating contractor The installation, service, and maintenance of this equipment must be performed by a licensed professional heating contractor. " Please see section entitled Important Regulatory and Installation Requirements in the Installation Instructions. H Product documentation Read all applicable documentation before commencing installation. Store documentation near boiler in a readily accessible location for reference in the future by service personnel. " For a listing of applicable literature, please see section entitled Important Regulatory and Installation Requirements in the Installation Instructions. H Carbon monoxide Improper installation, service and/or maintenance can cause flue products to flow into living space. Flue products contain poisonous carbon monoxide gas. " For information pertaining to the proper installation, service and maintenance of this equipment to avoid formation of carbon monoxide, please see the Installation Instructions of the Vitodens 200 Direct Vent System. WARNING Installers must follow local regulations with respect to installation of carbon monoxide detectors. Follow manufacturer s maintenance schedule of boiler. H Equipment venting Never operate boiler without an installed venting system. An improper venting system can cause carbon monoxide poisoning. H Warranty Information contained in this and related product documentation must be read and followed. Failure to do so renders warranty null and void. H Advice to owner Once the installation work is complete, the heating contractor must familiarize the system operator/ultimate owner with all equipment, as well as safety precautions/requirements, shut-down procedure, and the need for professional service annually before the heating season begins. 2
3 Index Page General Information About these Instructions... 5 Safety For your Safety... 5 Useful Tips Inform Yourself... 9 Getting started Your Vitodens 200 boiler Overview of controls and indicators Quick Reference Ready for Operation The main control options Your heating system comes factory preset Selecting a heating program (winter, summer) Changing room temperature Using Comfort Functions Switching DHW comfort function on/off Setting the party mode Activating the energy saving mode Using the remote programming option Reference Guide Switching On and Off Initial start-up and re-starting the heating system Shutting down the heating system Menu-driven Operation The programming unit is your assistant Space Heating Settings (Switching Times) How switching times work Scanning and changing switching times Domestic Hot Water Supply Settings (Switching Times) How switching times work Scanning and changing switching times Changing the domestic hot water temperature When you go on holidays Setting the energy saving mode for the holiday period 24 Other Settings Changing time and date Scanning temperatures and operating status Selecting the language Changing the heating pattern of the boiler
4 Emission Inspection Override Switch/Emission Test Switch Information Troubleshooting Guide Diagnosis and correction Service Instructions Service instructions for your heating system How to Save Energy Directories Overview of menu structures Lighting and operating instructions Alphabetical index
5 General Information/Safety About these Instructions Take note of all symbols and notations intended to draw attention to potential hazards or important product information. These include WARNING, CAUTION, and IMPORTANT. See below. WARNING Indicates an imminently hazardous situation which, if not avoided, could result in death, serious injury or substantial product/property damage. CAUTION Indicates an imminently hazardous situation which, if not avoided, may result in minor injury or product/property damage. IMPORTANT Warnings draw your attention to the presence of potential hazards or important product information. Cautions draw your attention to the presence of potential hazards or important product information. Helpful hints for installation, operation or maintenance which pertain to the product. This symbol indicates that additional, pertinent information is to be found in column three. This symbol indicates that other instructions must be referenced. For your Safety H Operation H Working on the equipment H Maintenance and cleaning Before operating the boiler, make sure you fully understand its method of operation. Your heating contractor should always perform the initial start-up and explain the system. Any warranty is null and void if these instructions are not followed. All personnel working on the equipment or the heating system must have the proper qualifications and hold all necessary licenses. Ensure main power to equipment, heating system, and all external controls has been deactivated. Close main gas supply valve. Take precautions in all instances to avoid accidental activation of power during service work. Regular inspection and service by a qualified heating contractor is important to the performance of the Viessmann Vitodens 200. Neglected maintenance impacts on warranty; regular inspection ensures clean, environmentally friendly and efficient operation. We recommend a maintenance contract with a qualified heating contractor. H Flue gas smell H Dangerous conditions H Technical information - Deactivate heating equipment. - Open windows and doors. - Inform your heating contractor. - Deactivate main power immediately. - Close gas supply valve. Literature applicable to all aspects of the Vitodens 200: - Technical Data Manual - Installation Instructions - Start-up/Service Instructions - Operating Instructions and User s Information Manual - System Design Guidelines Additional applicable literature: - Accessory manuals 5
6 Safety For your Safety (continued) H Carbon monoxide The U.S. Consumer Product Safety Commission strongly recommends the installation of carbon monoxide detectors in buildings in which gas-burning equipment is installed. Carbon monoxide (CO) is a colorless, odorless gas, which may be produced during incomplete combustion of fuel and/or when the flame does not receive an adequate supply of combustion air. Carbon monoxide can cause severe personal injury or loss of life. Therefore, carbon monoxide detectors that are in compliance with a nationally recognized standard (e.g. ANSI/UL , CSA ) should be installed and maintained in buildings that contain gas-burning equipment. Note: Viessmann does not test any detectors and makes no representation regarding any brand or type of detector. H For safe operation We recommend that you frequently: - Check for debris which could obstruct the flow of flue gases. The vent or chimney must not be blocked. A blocked or partially blocked vent or chimney can cause flue gases to leak into the structure. Flue gases leaking into the house can cause injury or death. Blocked or partially blocked chimneys must have the blockage removed by a qualified heating contractor. - Check pressure gage for correct system (water) pressure. Check for water on the floor from the discharge pipe of the pressure relief valve or any other pipe, pipe joint, valve or air vent. - Check for moisture, water, or appearance of rust on the flue gas pipes, their joints as well as vent dampers, or side wall vent terminals (if so equipped). - Ensure that nothing is obstructing the flow of combustion and ventilation air and no chemicals, garbage, gasoline, combustible materials, flammable vapors and liquids are stored (not even temporarily) in the vicinity of the boiler. -Donot allow unsupervised children near the boiler. Service/inspection of the boiler and the system is recommended once a year. Maintenance, service and cleaning are specified in the Installation Instructions. Before the heating season begins, it is recommended that the boiler and burner be serviced by a qualified heating contractor. Service contracts may be established through gas suppliers or other licensed contractors in your area. WARNING As there are no user-serviceable parts on the boiler, burner or control, the end-user must not perform service activities or adjustments of any kind on system components. Failure to heed this warning can cause property damage, severe personal injury, or loss of life. WARNING Improper installation, adjustment, service, or maintenance can cause flue products to flow into living space. Flue products contain poisonous carbon monoxide gas which can cause nausea or asphyxiation resulting in severe personal injury or loss of life. CAUTION Should overheating occur or the gas supply fail to shut off, do not disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance. WARNING The operator/ultimate owner is required to have the heating boiler, burners, and controls checked, as a minimum once per year, by the original installer or by a competent heating contractor familiar with the equipment. Defects must be corrected immediately. CAUTION Do not use this boiler if any part has been under water. Immediately call a qualified heating contractor to inspect the boiler and to replace any part of the control system and any gas control which has been under water. 6
7 Safety For your Safety (continued) Frozen water pipe hazard WARNING Failure to protect against frozen pipes could result in burst water pipes, serious property damage and/or personal injury. Boiler may shut down. Do not leave your home unattended for long periods of time during freezing weather conditions without turning off the water supply and draining water pipes or otherwise protecting against the risk of frozen pipes. Your heating boiler is designed to provide a warm and comfortable living environment. It is NOT designed to ensure against freezing of water pipes. The boiler is equipped with several safety devices that are designed to shut down the boiler and to prevent it from restarting in the event of various unsafe conditions. If your home will be unattended for an extended period of time during cold weather, you should... H Shut off the water supply to the building, drain the water pipes and add an antifreeze for potable water to drain traps and toilet tanks. Open faucets where appropriate. Or.. H Have someone check the building frequently during cold weather and call a qualified service agency if required. Or... H Install a reliable remote temperature sensor that will notify somebody of freezing conditions within the home. If your boiler remains off for an extended period of time during cold weather, water pipes may freeze and burst, resulting in extensive water damage and conditions in which mold could grow. Certain molds are known to cause respiratory problems, as well as to pose other serious health risks. In case of water damage, immediate measures should be taken to dry out affected areas as quickly as possible to prevent mold from developing. 7
8 Safety For your Safety (continued) If you notice fire coming from the appliance, call the fire department immediately! Do not attempt to extinguish the fire unless qualified to do so. WARNING Fire causes a risk of burns and explosion! H Shut down the boiler H Close fuel shut-off valves H Use a tested fire extinguisher, class ABC. Installation area conditions WARNING Incorrect ambient conditions can lead to damage to the heating system and put safe operation at risk. H Ensure ambient temperatures are higher than 32 F / 0 C and lower than 104 F / 40 C. H Prevent the air from becoming contaminated by halogenated hydrocarbons (e.g. as contained in paints solvents or cleaning fluids) and excessive dust (e.g. through grinding or polishing work). Combustion air for the heating process, and ventilation of the boiler room must be free of corrosive contaminants. To that end, any boiler must be installed in an area that has no chemical exposure. The list to the right indicates the main, currently known sources. H Avoid continuously high levels of humidity (e.g. through frequent drying of laundry). H Never close existing ventilation openings. Replacement components, spare and wear parts IMPORTANT Components which are not tested with the heating system may damage the heating system, or affect its functions. Installation or replacement may only be carried out by a qualified heating contractor. Sources of combustion and ventilation air contaminants Areas likely to contain contaminants: H New building construction H Swimming pools H Remodelling areas, hobby rooms H Garages with workshops H Furniture refinishing areas H Dry cleaning/laundry areas and establishments H Auto body shops H Refrigeration repair shops H Metal fabrication plants H Plastic manufacturing plants H Photo processing plants H Beauty salons Products containing contaminants: H Chlorine-type bleaches, detergents and cleaning solvents found in household laundry rooms H Paint and varnish removers H Hydrochloric acid, muriatic acid H Chlorine-based swimming pool chemicals H Spray cans containing chlorofluorocarbons H Chlorinated waxes and cleaners H Cements and glues H Refrigerant leaks H Calcium chloride used for thawing H Sodium chloride used for water softening salt H Permanent wave solutions H Adhesives used to fasten building products and other similar items H Antistatic fabric softeners used in clothes dryers 8
9 Inform Yourself Getting Started... The timer of the control unit switches between normal room temperature and reduced room temperature at the required times. 1. Normal room temperature for the times you spend at home and require a comfortably warm room temperature (e.g. 68 ºF/20 ºC). 2. Reduced room temperature for the times you are away from home. To save energy, a lower temperature is typically selected (e.g. 57 ºF/14 ºC). Times and duration of the two room temperatures can be set on the programming unit of your control. The temperature settings for both the normal room temperature and reduced room temperature can be set according to your personal preference. The timer of the control unit switches domestic hot water production on and off at the required times. 1. Domestic hot water heating can be set to take place during the times you spend at home and require hot water for your daily DHW requirements (e.g. for showering). 2. Domestic hot water heating can be set not to take place for the times you spend sleeping, for example. Times and duration of the domestic hot water production period can be set on the programming unit of your control. You may select a DHW temperature setting based on your personal preference of up to 140 ºF/60 ºC. The domestic hot water recirculation pump (if installed) ensures that domestic hot water is readily available when domestic hot water is drawn. 9
10 Inform Yourself Your Vitodens 200 Boiler Please ask your heating contractor to check off the appropriate box ( ). j Vitodens 200 without domestic hot water tank The control unit activates and deactivates space heating and supplies rooms with heat. j Vitodens 200 with separate domestic hot water tank Domestic hot water heating has priority over space heating. The control unit switches automatically to space heating when the preset domestic hot water temperature is reached. j Vitodens 200 with integrated DHW plate heat exchanger for instantaneous DHW heating Domestic hot water heating has priority over space heating. The control unit switches automatically to space heating when the heat exchanger temperature is satisfied (with comfort switch on) or when the preset domestic hot water temperature is reached (with comfort switch off). Overview of Controls and Indicators Programming Unit (removable) Pressure gage Display window Heating program selector switch A C B D - + i Burner fault reset button Emission test switch (override switch) Selector knob for normal room temperature Burner operating status indicator Burner fault indicator Boiler on/off switch Party button Energy savings button Selector knob for reduced room temperature Information button Factory default settings button Selector knob Flip-down cover Selector buttons DHW comfort function switch (only operational on Combi heating boiler with integrated instantaneous hot water heating) 10
11 Inform Yourself Overview of Controls and Indicators (continued) MAIN MENU Please select >HTG. CIRCUIT A:... A >HTG. CIRCUIT B:... B >DHW:... C >SYSTEM:... D >EXIT:... CLOSE COVER Operation The is a menu-driven programming unit. Upon opening the flip-down cover of the programming unit, the start menu showing all available adjustment options will appear in the display window. Select your adjustment option by pressing buttons A, B, C or D. An overview of the menu structures available can be found in section entitled Overview of menu structures on page 34 of this manual. 11
12 Ready for Operation The Main Control Options All settings can be adjusted directly on the boiler control or on the remote control (when the programming unit is used as remote control). The programming unit can be removed from the control unit and mounted on a wall-mount base (available as accessory) anywhere in your main living area and used as a remote control. In instances where the programming unit is used as remote control, a temperature indicator (available as accessory) must be installed in place of the programming unit in the control base on the boiler. The control unit is located behind the hinged cover in the front of the boiler. Open hinged cover of the control by exerting slight pressure with your fingertip on top of the cover. Ensure hinged cover is closed after every use to guarantee splash protection. Your heating system comes factory preset... The control unit comes factory preset to a standard operating mode. This means your heating system is ready for operation. All factory default settings can be changed to reflect your personal preferences. Date and time The date and time are factory preset and are updated through the built-in long-life battery. Should time and/or date be incorrect please see section entitled Changing Time and Date on page 25 in this manual. Heating program The heating program is set to Space heating and domestic hot water, i.e. space heating and domestic hot water production take place in accordance with preset switching times. Switching times The switch-on time is set to 6:00 hrs, the switch-off time to 22:00 hrs. Between 6:00 hrs and 22:00 hrs, space heating takes place at normal room temperature with domestic hot water production (if installed) when required. Between 22:00 hrs and 6:00 hrs, space heating takes place at reduced room temperature. Press button D to reset the switching times to their factory default settings. Please note that this will reset all altered values to their original factory default setting. 12
13 Ready for Operation Selecting a Heating Program (winter, summer) Select one of the following heating programs according to your personal requirements. Space heating and domestic hot water H Space heating at normal or reduced room temperature according to preset switching times H Domestic hot water production (with DHW tank installed or with Combi heating boiler) H Freeze-up protection of boiler and the DHW storage tank. Domestic hot water only H No space heating H Domestic hot water production (with DHW tank installed or with Combi heating boiler) H Freeze-up protection of boiler and DHW storage tank. Standby operation H No space heating H No domestic hot water production H Freeze-up protection of boiler and DHW storage tank. e.g. for winter months and transitional periods. e.g. for summer months. e.g. for summer holiday period. IMPORTANT The circulation pumps are switched on for a short time every 24 hours to prevent them from seizing up. 13
14 Ready for Operation/Using Comfort Functions Changing Room Temperature In the Space heating and domestic hot water heating program, space heating takes place at normal room temperature and reduced room temperature depending on preset switching times. You can set the required room temperature as follows. Colder Warmer Normal room temperature (factory default setting: 6:00 hrs to 22:00 hrs) Setting 5 corresponds to a room temperature of approx. 68 ºF/20 ºC with a correctly adjusted heating curve. Normal room temperature can be set between 41 and 95 ºF/ 5 and 35 ºC. Example For the times you spend at home and require a comfortably warm room temperature. Colder Warmer Reduced room temperature (factory setting: 22:00 hrs to 6:00 hrs) Setting e corresponds to a room temperature of approx. 41 ºF/5 ºC with a correctly adjusted heating curve. Reduced room temperature can be set between 41 and 95 ºF/ 5and35ºC. Example At nighttime or when you are away from home. SELECTED ROOM TEMP. PREVIOUS: 20ºC CURRENT: 22ºC INFO: OPEN COVER Changing the room temperature 1. Turn selector knob s or m. The (previous and current) temperature values appear in the display window. 2. Set the (current) temperature required using the selector knob. 3. The display automatically disappears after approx. 5 seconds. The selected temperature is stored. Please reference section Changing the heating pattern of the boiler on page 26 in this manual. Switching DHW Comfort Function On/Off (for Combi Series with integrated instantaneous DHW heat exchanger) When the comfort function is activated, the integrated instantaneous hot water heating function maintains a certain domestic hot water temperature level (standby). Domestic hot water is thus readily available when required. With button / the comfort function can be switched on and off. The DHW comfort function can be deactivated in order to avoid frequent activation of the boiler, i.e. to reduce the energy consumption used for maintaining a certain DHW temperature if no domestic hot water is drawn (e.g. at nighttime). 14
15 Using Comfort Functions Setting the Party Mode Activate the party mode when you require space heating for a short period of time, independent of the preset heating program and outside the preset switching times. You can adjust the room temperature (party temperature) to suit your personal preference. MONDAY, :30 pm PARTY MODE SELECTED: 20ºC CHANGE PARTY TEMP.: OPEN COVER BOILER TEMP.: 53ºC To activate the party mode Press the party button g. The party mode is now displayed together with the preset party temperature. To change the room temperature (party temperature) Open the flip-down cover of the programming unit and follow the instructions in the display window. Ensure cover is closed when change is made. Example Use the party mode option when you wish to stay up longer than usual (e.g. when you have guests) and require space heating without having to change the switching times. To cancel the party mode The party mode is cancelled automatically the next time the preset heating program switches to normal room temperature. If you want to cancel the party mode immediately, press the party button g again. Activating the Energy Saving Mode Activate the energy saving mode when you require particularly economical space heating for a short period of time. In the energy saving mode, the preset room temperature is automatically lowered by approx. 3.6 ºF/2 ºC. TUESDAY, :35 HRS ENERGY SAVING MODE S BOILER TEMP.: 53ºC INFO: OPEN COVER To activate the energy saving mode Press the energy saving button S. The energy saving mode is now displayed. To cancel the energy saving mode The energy saving mode is cancelled automatically the next time the preset heating program switches to reduced room temperature. If you want to cancel the energy saving mode immediately, press the energy saving button S again. Example Use the energy saving mode option when you are not at home for a period of time (e.g. to go shopping) and wish to lower the temperature without having to adjust the temperature selector switch and the switching times. 15
16 Using Comfort Functions/Switching On and Off Using the Remote Programming Option The programming unit provides you with the option of programming your right from your armchair. Simply remove the programming unit from the control base in the front of the boiler or, if used as remote control, from the wall-mount base, and perform your programming from wherever convenient. Be sure to insert the programming unit in the control unit or wall-mount base upon completion of your programming The following options can be programmed: H Time programs H Room temperature values H Heating curves H Time and date Before using the remote programming option for the first time, insert the programming unit in the control unit or in the wall-mount base for approx. 2 minutes. Switch off the heating system switch on the control unit before removing and inserting the programming unit. Initial Start-up and Re-starting the Heating System Initial start-up and adjustment of the control unit to local conditions and the structural characteristics of your building must be performed by your heating contractor. We recommend that you contact your heating contractor before re-starting the heating system if it has been shut down for a long period of time. To start up the system 1. Check heating system pressure on the pressure gage 1. Minimum system pressure 12 psig. If the needle of the pressure gage is below 12 psig, the system pressure is too low, in which case you must contact your heating contractor. 2. Open the gas shutoff valve 2 (field supplied) Switch on line voltage (e.g. at separate fuse/circuit breaker). 4. Switch on the heating system on/off switch 3. Your heating system is now ready for operation. 16
17 Switching On and Off Shutting Down the Heating System In case you are not intending to use your heating system for a period of time, e.g. during your summer holidays, switch your heating system to standby operation (see section entitled Selecting a heating program, page 13). If you do not want to use your heating system for a longer period of time (several months), you should shut it down. We advise you to contact your heating contractor before shutting down the heating system for longer periods of time. Your heating contractor will then take any required action/precautions, e.g. providing freeze-up protection of the system or safeguarding the heat exchanger surfaces. To shut down the heating system 1. Switch off the heating system on/off switch. 2. Close gas shutoff valve and secure against unintentional opening. 3. Switch off line voltage (e.g. at separate fuse/circuit breaker). The power supply to the system is now switched off. There is no freeze-up protection. All settings of the control unit still remain intact. 17
18 Menu-driven Operation The Programming Unit Is Your Assistant With the programming unit you can set the heating system settings according to your personal preferences and requirements by using the various functions and adjustment options offered through the programming unit. Most of the functions offered are easily accessible through the main menu. Thus switching times, temperatures and heating curves can be navigated and adjusted in a straight-forward fashion. MAIN MENU Please PLEASE select SELECT! >HTG. CIRCUIT A: A:... AA >HTG. CIRCUIT B:... B B >DHW:... CC >SYSTEM:... DD >EXIT:... CLOSE COVER Information button D Factory default setting Display window (with cover open) Overview of possible settings G Selector knob Flip-down cover A, B, C, D Selector buttons When you open the cover on the programming unit, the display shows an overview of possible settings. Select the settings you require by using selector buttons A, B, C or D. If the display requests you to enter a numerical value, you can define the value with selector knob G. The steps required to make individual settings are explained in detail on the following pages. You will find an overview of the menu structures (in section entitled Overview of Menu Structures ) on page 34 of this manual. 18
19 Space Heating Settings (Switching Times) How Switching Times Work... By setting the switching times accordingly, space heating can switch up to 4 times a day between normal room temperature and reduced room temperature. In the factory default setting, space heating takes place at normal room temperature between 6:00 hrs until 22:00 hrs every day of the week. When setting switching times, take into account the reaction time required by your heating system. Select earlier switch-on and switch-off times accordingly. Scanning and Changing Switching Times To change switching times for the day displayed Press the following buttons: 1. A for Heating circuit A or B for Heating circuit B 2. A for Timer 3. A for Switching times HC A /ALL DAYS 06:00-22:00 --:-- --:-- --:-- --:-- --:-- --:-- >CHANGE:, THEN A >RETAIN:... B >BACK:... C 4. A for Time schedule 5. Turn the G selector knob to set the switching times 6. A to confirm each setting You can scan the switching times for the day displayed following the same procedure. Exit the switching time setting mode by closing the cover or by pressing the C button to return to menu option Switching times. In each of the 4 input lines of the display window you can enter one switch-on time and one switch-off time at which the normal room temperature is to be switched on/off. In case you inadvertently change a switching time, you can reset it to the original setting by pressing button B, as long as the change has not been confirmed. 19
20 Central Heating Settings (Switching Times) Scanning and Changing Switching Times (continued) To change switching times for other days of the week PLEASE SELECT! /ALL DAYS IDENTICAL/ /MO/TU/WE/TH/FR/ /SA/SU/ /FACTORY SETTING/ >SELECT:...A >CONFIRM:...B >BACK:...C Press the following buttons: 1. A for Heating circuit A or B for Heating circuit B 2. A for Timer 3. A for Switching times 4. B for Different days 5. A continue pressing A until the desired day flashes 6. B to confirm your selection Examples: Select MO if you wish to change the switching times for Monday only. Select ALL DAYS IDENTICAL if you wish to set the same switching times for every day of the week. HC A /ALL DAYS 06:00-22:00 --:-- --:-- --:-- --:-- --:-- --:-- >CHANGE:, THEN A >RETAIN:...B >BACK:...C 7. A for Time schedule 8. Turn the G selector knob to set the switching times 9. A to confirm each setting You can scan the switching times for the day displayed following the same procedure. Exit the switching time setting mode by closing the cover or by pressing the C button to return to menu option Switching times. Please note: In each of the 4 input lines of the display window you can enter one switch-on time and one switch-off time at which the normal room temperature is to be switched on/off. In case you inadvertently change a switching time, you can reset it to the original setting by pressing button B, as long as the change has not been confirmed. 20
21 Domestic Hot Water Supply Settings (Switching Times) How Switching Times Work... On Vitodens 200 boilers equipped with a stand-alone domestic hot water storage tank, domestic hot water production can be switched on and off up to 4 times daily by setting the switching times accordingly. In the factory default setting, domestic hot water production takes place continuously between 6:00 hrs until 22:00 hrs every day of the week. Switching times for the DHW recirculation pump (if installed) can be set separately. When setting switching times, take into account the reaction time required by your heating system. Choose correspondingly earlier switch-on and switch-off times. Scanning and Changing Switching Times To change switching times for the day displayed Press the following buttons: 1. C for DHW 2. A for DHW tank or B for DHW recirc. pump 3. A for Time schedule DHW TANK/ALL DAYS 06:00-22:00 --:-- --:-- --:-- --:-- --:-- --:-- >CHANGE:, THEN A >RETAIN:...B >BACK:...C 4. A for Time schedule 5. Turn the G selector knob to set the switching times 6. A to confirm each setting You can scan the switching times for the day displayed following the same procedure. Exit the switching time setting mode by closing the cover or by pressing the C button to return to menu option Switching times. Please note: In each of the 4 input lines of the display window you can enter one switch-on time and one switch-off time at which domestic hot water production or the DHW recirculation pump is switched on/off. Activation periods for the DHW recirculation pump should be selected for periods when you are at home and require domestic hot water. In case you inadvertently change a switching time, you can reset it to the original setting by pressing button B, as long as the change has not been confirmed. 21
22 Domestic Hot Water Supply Settings (Switching Times) Scanning and Changing Switching Times (continued) To change switching times for other days of the week Press the following buttons: 1. C for DHW 2. A for DHW tank or B for DHW recirculation pump Examples: Select MO if you wish to change the switching times for Monday only. Select ALL DAYS IDENTICAL if you want to set the same switching times for every day of the week. PLEASE SELECT! /ALL DAYS IDENTICAL/ /MO/TU/WE/TH/FR/ /SA/SU/ /FACTORY SETTING/ >SELECT:...A >CONFIRM:...B >BACK:...C 3. A for Time schedule 4. B for Different days 5. A continue pressing until desired day flashes 6. B to confirm your choice DHW TANK / ALL DAYS 06:00-22:00 --:-- --:-- --:-- --:-- --:-- --:-- >CHANGE:, THEN A >RETAIN:...B >BACK:...C 7. A for Time schedule 8. Turn the G selector knob to set the switching times 9. A to confirm each setting You can scan the switching times for the day displayed following the same procedure. Exit the switching time setting mode by closing the cover or by pressing the C button to return to menu option Switching times. Please note: In each of the 4 input lines of the display window you can enter one switch-on time and one switch-off time at which domestic hot water production or the DHW recirculation pump is switched on/off. In case you inadvertently change a switching time, you can reset it to the original setting by pressing button B, as long as the change has not been confirmed. 22
23 Domestic Hot Water Supply Settings (Switching Times) Changing the Domestic Hot Water Temperature Only on boiler with separate DHW tank You can select the domestic hot water temperature according to your personal preference (e.g. for showering). Press the following buttons: 1. C for DHW 2. A for DHW tank 3. B for Temperature DHW TANK/TEMP. DHW TEMP.: PREVIOUS: 55ºC CURRENT: 50ºC >CHANGE:, THEN A >RETAIN:...B 4. A for Change temperature 5. Turn the G selector knob to set the temperature 6. A to confirm each setting Exit the temperature setting mode by closing the cover or by pressing the C button to return to menu option Switching times. In case you inadvertently change a temperature setting, you can reset it to the original setting by pressing button B, as long as the change has not been confirmed. 23
24 When you go on holidays... Setting the Energy Saving Mode for the Holiday Period When going away on a holiday and you wish to reduce the energy consumption of your heating system as much as possible, select one of the following heating programs. Standby operation H No space heating H No domestic hot water heating H Freeze-up protection of the heating system Holiday program H Constant room temperature, can be set between 41 and 95 ºF/ 5and35ºC H No domestic hot water heating H Programmable for 1 to 99 days H Afterwards, space heating and domestic hot water heating automatically take place again based on selected switching times. e.g. for your holiday period. IMPORTANT The circulation pumps are activated for a short period of time every 24 hours to prevent them from seizing up. e.g. to protect house plants during your winter holiday and when you want a warm home to return to. Press the following buttons: 1. A for Heating circuit A or B for Heating circuit B 2. A for Timer 3. B for Holiday program 4. A for Change , 11:06 HC A /HOLIDAY PROG. ON ,00:00 OFF ,24:00 TEMP. 14ºC >CHANGE:...A >DELETE:...B >MAIN MENU:...D To enter the beginning and end of the holiday program 5. A for Time schedule 6. Turn the G selector knob to set the beginning (ON) and end (OFF) of the holiday program. 7. A to confirm each setting Please bear in mind that the holiday program always ends at 24:00 hrs on the last day selected. Therefore set the program to end on the day prior to your return. Your heating system will then be active again on the day you return home. Select Delete if you wish to cancel the holiday program prematurely , 12:50 HC A /HOLIDAY PROG. SELECTED TEMP. PREVIOUS: 14ºC CURRENT: 16ºC >CHANGE:, THEN A >MAINTAIN:...B To change the temperature for the holiday program 8. B for Change temperature 9. Turn the G selector knob to set the temperature. 10. A to confirm your selection 24
25 Other Settings Changing Time and Date (if required) SYSTEM / CLOCK TODAY IS THURSDAY :30 HRS >CHANGE DATE:...A >CHANGE TIME:...B >BACK:...C Press the following buttons: 1. D for System 2. A for Factory setting 3. A for Clock You are now in the Clock menu. Follow the instructions in the menu and set the required date and/or time. Scanning Temperatures and Operating Status HC A / STATUS THE PROGR. UNIT IS ASSIGNED TO: HC A >CONTINUE...A >BACK:...C >MAIN MENU:...D You can access and scan various system temperatures and operating status information as follows. Press the following buttons: 1. A for Heating circuit A or B for Heating circuit B 2. C for Operating status 3. A for Continue to scan the required values Selecting the Language LANGUAGE / LANGUE Press the following buttons: 1. D for System 2. A for Factory setting >ENGLISH:...A >FRANÇAIS:...B 3. C for Language >BACK / RETOUR:...D 25
26 Other Settings Changing the Heating Pattern of the Boiler The heating pattern of your boiler is determined by the outdoor temperature and the settings of the shift and slope of the heating curve. You may change these settings if you feel that the room temperature does not meet your requirements during the heating season over a longer period of time. Should you change these settings, please ensure the difference in heating pattern is observed over a sufficiently long period of time before deciding to alter these again. Short-term changes in room temperature are made with s or m selector knobs (see Changing room temperature on page 14 in this manual). Heating curves represent the relationship between the outdoor temperature and the boiler water or supply temperature. Put simply: The lower the outdoor temperature, the higher the boiler water or supply temperature. Please note: In the factory default setting, the slope is set to 1.4 and the shift to 0. The heating curves shown are based on the following settings: Shift of heating curve = 0 Normal room temperature s = 5 (corresponding to approx. 68 ºF/20 ºC) The slope of the heating curve is usually within the indicated range. High temperature heating system, e.g. fintube radiation, fan coils Medium temperature heating system, e.g. cast iron radiation, staple-up radiant floor heating Low temperature heating system, e.g. radiant floor heating Changing the heating pattern by adjusting the heating curve HC A / HTG. CURVE SLOPE: 1.4 SHIFT: 0 ºC MAX. LIMIT.: 127ºC >CHANGE:, THEN A >MAINTAIN:...B >BACK:...C Press the following buttons: 1. A for Heating circuit A or B for Heating circuit B 2. B for Heating curve 3. A for Change 4. Turn the G selector knob to change the slope and shift and the max. temperature limit 5. A to confirm each setting Please use table on page 27 of this manual ( Change heating pattern if... ) as as reference as to when to change the pattern of your heating system. If an underfloor heating circuit is installed, a max. supply temperature limit of 113 ºF/45 ºC can be selected, for example. 26
27 Other Settings Changing the Heating Pattern of the Boiler (continued) Change heating pattern if... Action Example... your living area is too cold... at cold time of year Adjust slope of heating curve upward by one increment HC A / HTG. CURVE SLOPE: 1.5 SHIFT: 0ºC MAX. LIMIT: 127ºC >CHANGE:, THEN A >MAINTAIN:... B >BACK:... C... your living area is too warm... at cold time of year Adjust slope of heating curve downward by one increment HC A / HTG. CURVE SLOPE: 1.3 SHIFT: 0ºC MAX. LIMIT: 127ºC >CHANGE:, THEN A >MAINTAIN:... B >BACK:... C... your living area is too cold... at transitional time of year and... at cold time of year. Adjust shift of heating curve upward (e.g. +3 ºC) HC A / HTG. CURVE SLOPE: 1.4 SHIFT: +3ºC MAX. LIMIT: 127ºC >CHANGE:, THEN A >MAINTAIN:... B >BACK:... C... your living area is too warm... at transitional time of year and... at cold time of year. Adjust shift of heating curve downward (e.g. 3 ºC) HC A / HTG. CURVE SLOPE: 1.4 SHIFT: -3ºC MAX. LIMIT: 127ºC... your living area is too cold... at transitional time of year, but... warm enough at cold time of year.... your living area is too warm... at transitional time of year, but... warm enough at cold time of year. Adjust shift of heating curve upward (e.g. +3 ºC), and slope downward by one increment Adjust shift of heating curve downward (e.g. 3 ºC), and slope upwards by one increment >CHANGE:, THEN A >MAINTAIN:... B >BACK:... C HC A / HTG. CURVE SLOPE: 1.3 SHIFT: +3ºC MAX. LIMIT: 127ºC >CHANGE:, THEN A >MAINTAIN:... B >BACK:... C HC A / HTG. CURVE SLOPE: 1.5 SHIFT: -3ºC MAX. LIMIT: 127ºC >CHANGE:, THEN A >MAINTAIN:... B >BACK:... C 27
28 Emission Inspection Override Switch/Emission Test Switch The following information is provided for emission inspection purposes, and for temporary override of the outdoor reset control. Override/Emission test switch =Manual operation =Automatic For flue gas measurement at constant boiler water temperature for a short period of time: 1. Open hinged cover on the enclosure panel. 2. Turn the emission test switch S from a to h. 3. Activate heat emitters (e.g. by opening the thermostatic valves). The following functions are triggered when using the emission test switch (manual operation): H The boiler water temperature is limited by a limit aquastat. H The circulation pumps are activated. H The mixing valve (if installed) remains in its control mode. H The burner is switched on (at max. input). 4. After completing the measurement, turn emissions test switch S back to a. 5. Close cover. 28
29 Troubleshooting Guide Diagnosis and Correction If a fault occurs on your heating system, it will be displayed in the display window TUESDAY, with the cover closed. Using the scanning function, you can access the fault 15:20 HRS cause in the display and inform your heating contractor accordingly. PROGRAM SPACE HEATING: ON BOILER TEMP.: 53ºC...FAULT... INFO: OPEN COVER Open cover and press the following buttons: FAULT SEARCH FAULT: OUTDOOR TEMP. SENSOR >HEATG. CONTRACTOR:i >ACKNOWLEDGE: A 1. A for Fault search. The fault cause is displayed in plain language or in form of an error code. 2. i for Heating contractor. The address and telephone number of your heating contractor are displayed (given the information was entered at time of start-up). 3. i to exit the information menu. 4. A for Acknowledge The fault message and corresponding alarm are cancelled. The fault message will re-appear at 0:00 hrs the following day if the fault has not been addressed in the meantime. 29
30 Troubleshooting Guide Diagnosis and Correction (continued) Fault Cause Corrective Action Heating system does not start up Heating system switch turned to OFF on control unit Turn switch to ON on control unit. Circuit breaker or fuse in power Inform heating contractor. supply, in power/pump module or in boiler control unit has blown or tripped Burner does not switch on or only No gas Open gas shut-off valve. intermittently Burner does not start up; red burner fault lamp U is lit on control unit Rooms are cold although burner is operating If mixing valve controller installed: Boiler in operation, but heating circuit cold Control unit incorrectly programmed or set Fault on control unit Faulty start-up Low water level or pressure, water pressure sensor has activated Domestic hot water supply has priority (operation with DHW storage tank only) Mixing valve controller defective Check, and if necessary, correct setting of heating program selector switch and timer programming. Inform heating contractor. After consulting your heating contractor, the boiler can be operated temporarily at constant boiler water temperature by operating the override/emissions test switch S. Press burner fault reset button EU. Should this attempt fail, contact your heating contractor. Inform heating contractor. Wait until the domestic hot water heating is complete. Pull out motor lever and adjust mixing valve lever 1 manually. Inform heating contractor. 1 Fault flashes in display window Faultonheatingsystem Make a note of the fault code and inform heating contractor (see page 29 in this manual). Warning Visually inspect the vent termination for any signs of blockage. Under cold climate conditions (sustained temperatures below 0 F / -18 C) the vent termination may be severely blocked by icicle and frost build-up. The boiler control will automatically shut down the boiler should air or vent be blocked. Remove blockage if possible. Acknowledge the fault and the boiler should attempt to restart. If blockage is not obvious and cannot be removed, contact a qualified service technician. 30
31 Troubleshooting Guide Diagnosis and Correction (continued) Fault Cause Corrective Action Please change batteries appears in display window or Display window fails to illuminate Batteries discharged 1. Switch off heating system on/off switch on the control unit as well as line voltage. 2. Remove the programming unit. 3. Remove battery compartment from rear panel. 4. Change batteries. Use alkaline batteries (AAA). IMPORTANT Insert batteries as illustrated. 5. Insert battery compartment into rear panel. Snap programming unit back into place. 6. Switch on heating system on/off switch and line voltage. IMPORTANT Please be sure to dispose discharged batteries in an environmentally sound manner. Please inquire at local recycling facilities about public recycling programs available. 31
32 Service Instructions Service Instructions for Your Heating System Viessmann strongly recommends inspection/service of the boiler and the system by a licensed professional heating contractor once a year. Before the heating season begins, the boiler with its burner(s) and direct vent system should be serviced by a qualified heating contractor. Service contracts may be established through gas suppliers or other licensed contractors in your area. Regular inspection/service ensures troublefree, energy-efficient and environmentally friendly heating activity of your heating system. Boiler All boilers must be cleaned on a regular basis as debris build-up will result in increased flue gas temperature, and thus in increased energy consumption. Domestic hot water storage tank Inspection and (if necessary) cleaning of the tank must take place within 2 years of initial start-up and as required thereafter. Cleaning of the inside surfaces of the domestic hot water storage tank, including domestic hot water connections, may only be performed by an licensed professional heating contractor. Vitocell 100: Viessmann recommends an annual inspection, and replacement if required, of the consumable anode by a licensed professional heating contractor. The inspection can be carried out during regular operation of the heating system; shut-down is not required. The heating contractor measures the protective current with an anode testing instrument. Drinking water filter (if installed) For hygienic reasons H replace filter element every 6 months on filters which cannot be flushed back, and perform a visual inspection every 2 months, H flush back reversible flow filters every 2 months. Notes on operation: H Ensure boiler room and boiler are clean. H Regularly check heating system pressure on the pressure gage: If the needle of pressure gage is below 12 psig, the system pressure is too low; in this case, please contact your heating contractor. IMPORTANT If the domestic cold water supply to the hot water storage tank has a water treatment device (water softener) installed, ensure its proper working condition is checked regularly by your heating contractor. The same applies if a dirt trap or a water filter is installed in the domestic cold water supply. Any of these devices installed in the domestic cold water supply must be flushed out and serviced on a regular basis. Please follow manufacturer s instructions. 32
33 How to Save Energy How to Save Energy... by heating correctly Apart from taking advantage of the benefits of a modern heating system, there is a lot you can do yourself to achieve additional fuel savings. For instance: H Don t overheat: Aim at a room temperature of 68 ºF/20 ºC. Every degree less in room temperature will reduce your heating bills by up to 6 %. H Close window shutters (if installed) at dusk. H Operate thermostatic valves 2 correctly. H Don t obstruct radiators 3 and thermostatic valves 2. H Make use of individual adjustment options of the control unit 4; e.g. normal room temperature alternating with reduced room temperature. H Set the domestic hot water temperature of the DHW tank 5 on the control unit 4. H Control your consumption of hot water: A shower generally consumes less energy than a bath.... with regular maintenance Regular maintenance check-ups of your heating system 6 by a licensed professional heating contractor will ensure energy savings and environmentally friendly operation.... with effective insulation If you wish to make use of additional energy-saving measures, check the thermal insulation: H of heating and domestic hot water pipes. H of external walls and the roof. H between heated and unheated rooms. H of the windows. 33
34 Directories Overview of Menu Structures The main menu provides you with options which direct you to further functions and information. The overview is displayed upon opening the cover of the programming unit. Menu structure Heating circuits A and B >HEATING CIRCUIT A >HEATING CIRCUIT B A or B >TIMER >HEATING CURVE A B >SWITCHING TIMES A >TIME SCHEDULE >DIFFERENT DAYS >DOMESTIC HOT >OPERATING C >HOLIDAY PROGRAM B WATER STATUS >CHANGE A >TIME SCHEDULE >SYSTEM >DELETE >TEMP. CHANGE >CHANGE A >SLOPE >SHIFT >MAX. LIMIT >IS ASSIGNED TO >ROOM TEMP. A >HC PUMP A MIXING VALVE >SUPPLY TEMP. A When the programming unit is used as remote control 34
35 Directories Overview of Menu Structures (continued) Menu structure Domestic hot water >HEATING CIRCUIT A >DHW TANK A >TIME SCHEDULE A >TIME SCHEDULE >HEATING CIRCUIT B >DHW RECIRC. B >TEMPERATURE B >DIFFERENT DAYS >DOMESTIC HOT C PUMP >OPERATING C WATER >SYSTEM STATUS >CHANGE TEMPERATURE >DHW TANK STATUS >TIME SCHEDULE A >TIME SCHEDULE >OPERATING STATUS B >DIFFERENT DAYS >DHW RECIRC. PUMP (STATUS) Menu structure System >HEATING CIRCUIT A >FACTORY SETTING A >CLOCK A >CHANGE DATE >HEATING CIRCUIT B >OPERATING B >DIFFERENTIAL B >CHANGE TIME >DOMESTIC HOT STATUS TEMP. WATER D >INSTALLER SETUP C >LANGUAGE C >CHANGE TEMP. >SYSTEM >ENGLISH >FRANÇAIS >IS ASSIGNED TO >BOILER TEMP. A >BURNER A >OUTDOOR TEMP. A Must be performed by heating contractor A >FLUE GAS A >RETURN TEMPERATURE A >SCAN CODING CARD It is not possible to display the flue gas temperature. It is not possible to display the return temperature. 35
36 Information Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING WARNING:Ifyoudonotfollowtheseinstructionsexactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. OPERATING INSTRUCTIONS C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 1. STOP! Read the safety information above on this label. 2. Set thermostat or other operating control to lowest setting. 3. Turn off all electric power to the appliance. 4. This device is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. Manual gas shutoff Closed 5. Close main gas shut-off valve. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow B in the safety information above on this label. If you don t smell gas, go to the next step. 7. Open main gas shut-off valve. 8. Turn on all electric power to the appliance. 9. Set thermostat or other operating control to desired setting. 10. If the appliance will not operate, follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier. Open 1. Set thermostat or other operating control to lowest setting. TO TURN OFF GAS TO BOILER 2. Turn off all electric power to the appliance if service is to be performed. 3. Close main gas shut-off valve. 36
37 Directories Alphabetical Index C Changing the batteries, 31 Changing the date, 25 Changing the domestic hot water temperature, 23 Changing the room temperature, 14 Changing the shift of the heating curve, 27 Changing the slope of the heating curve, 27 Changing the switching times, 19 Changing the time, 25 Consumable anode, 32 Controls, 10 Correcting faults, 29 D Dangerous conditions, 5 DHW recirculation pump, 21, 22, 35 Diagnosis, 29 Display window, 10 Domestic hot water, 13 Domestic hot water tank, 10, 32 Domestic hot water only, 13 Domestic hot water temperature, 23 Drinking water filter, 32 E Efficiency directive, 33 Emission test switch, 28 Energy savings mode S, 28 F Factory default setting, 10, 12 Fault messages, 29 Flue gas smell, 5 Freeze-up protection, 13, 17 G Gas shutoff valve, 5, 16 H Heating contractor, 2, 32 Heating curve, 26 Heating pattern, 26 Heating program selector switch, 10 Heating system on/off switch, 10, 17 Holidays, 24 I Index, 3 Individual switching times, 19 Initial start-up, 16 Installer setup, 35 L Language selection, 25 M Maximum supply temperature limit, 26 Menu structure (overview), 34 Minimum system pressure, 16 N Normal room temperature, 9, 14 O Operating instructions in brief, 12 Override switch/emission test switch, 28 Overview of controls and indicators, 10, 18 P Party Mode g, 15 Remote programming option, 16 Pressure gage, 10, 16 S Safety, 5, 2 Saving energy, 33 Scanning the operating status, 25 Scanning the temperature values, 25 Selecting the heating program, 13 Sensor fault display, 29 Service contract, 32 Service instructions, 32 Setting the holiday program, 24 Shutting down the heating system, 17 Smell of fumes, 5 Space heating and domestic hot water, 13 Standby mode, 13 Starting up the heating system, 16 Switching times in factory default settings, 12 T Troubleshooting guide, 29 U Using the programming unit away from the control unit (remote programming option), 16 V Venting, 2 Vitocell 100, 32 W Working on the equipment, 5 R Reduced room temperature, 9, 14 Re-starting, 16 37
38 38
39 39
40 Viessmann Manufacturing Company (U.S.) Inc. 45 Access Road Warwick, Rhode Island USA Tel. (401) Fax (401) Quick Reference C F Viessmann Manufacturing Company Inc. 750 McMurray Road Waterloo, Ontario N2V 2G5 Canada Tel. (519) Fax (519) [email protected] Technical information subject to change without notice Printed on environmentally friendly (recycled and recyclable) paper.
Operating Instructions & User s Information Manual VITODENS 100-W WARNING. IMPORTANT Read and save these instructions for future reference.
Operating Instructions & User s Information Manual Please file in Service Binder Vitodens 100-W WB1A Series Wall-mounted, natural gas-fired condensing boiler For natural gas only Heating input NG 29 to
Operating Instructions & User s Information Manual VITODENS 100-W WARNING WARNING IMPORTANT. Read and save these instructions for future reference.
Operating Instructions & User s Information Manual Vitodens 100-W WB1B Series Wall-Mounted, gas-fired condensing boiler with optional on demand hot water CombiPLUS Kit Heating input: 37 to 118 MBH 10.8
Operating Instructions. VITODENS r 200/222 Series With Vitotronic 200 HO1B Controls WARNING WARNING IMPORTANT
Operating Instructions Vitodens 200-W, B2HA and B2HB Models 19 to 150 Wall-mounted, gas-fired condensing boiler For operation with natural gas and liquid propane gas Heating input: 12 to 530 MBH 3.5 to
Tankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRTNG199 / WGRTLP199 WGRTCNG199 / WGRTCLP199 NOTICE: Westinghouse reserves the right to make product changes or updates without notice and will not
Operating Instructions & User s Information Manual VITODENS 200 WARNING. IMPORTANT Read and save these instructions for future reference.
Operating Instructions & User s Information Manual Please file in Service Binder Vitodens 200-W WB2B Series Wall-mounted, gas-fired condensing boiler For natural gas and liquid propane Heating input 31
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
Operating instructions
Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers
For the owner Instructions for use ecotec Wall hung room sealed fan assisted condensing boilers GB Contents Specified use Notes on these instructions Specified use... Notes on these instructions.... Storage
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
6720646148-11/2010 US/CA
6720646148-11/2010 US/CA (en) For the user User s Instructions Condensing gas boiler Logamax plus GB162- L.B. 80 kw/100 kw Please read thoroughly before operating This manual is available in the English
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Condensing Water Heater Operation Manual Model NPE-180A/ 210A/ 240A NPE-180S/ 210S/ 240S * Lead Free Keep this manual near this water heater for future reference whenever maintenance or service is required.
Baxi Combi 80e & 105e
Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
VIESMANN. Operating instructions VITODENS VITOLADENS VITOPEND. for the system user
Operating instructions for the system user VIESMANN Heating system with the Vitotronic 200 control unit, type HO1B for weather-compensated mode VITODENS VITOLADENS VITOPEND 1/2011 Please keep safe. Safety
DUCT TYPE AIR CONDITIONER
OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES AIR CONDITIONER DUCT TYPE English Deutsch
Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler
User s Operating Instructions Baxi Combi Instant 8e & 15e Gas Fired Wall Mounted Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
User Manual. Gas fired condensing wall hung boiler. G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw)
User Manual Gas fired condensing wall hung boiler G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw) CLAS HE R 12 CLAS HE R 18 CLAS HE R 24 Country of destination GB, IE
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
USER S INFORMATION MANUAL
CONTENTS HOW YOUR SYSTEM WORKS......... 2 COOLING CYCLE....................... 2 HEATING CYCLE (HEAT PUMPS).......... 2 SYSTEM OPERATION................... 2 SETTING THE THERMOSTATS............ 2 THERMOSTATS.....................
Split Type Room Air Conditioner. KSWM units
OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Caution! Observe the safety instructions of this installation and maintenance manual before placing the boiler in operation. Danger!
Caution! Observe the safety instructions of this installation and maintenance manual before placing the boiler in operation. Danger! All installation, burner set-up and adjustment, and maintenance operations
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
User s Operation Manual - contents
User s Operation Manual - contents Safety Instructions Personal Safety Warranty Operating Instructions Maintenance Troubleshooting & Error Code Guide Safety Related Sysmbols 3 Warning Safety Precautions
To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)
OPERATION MANUAL Split System Ducted Air Conditioner To suit Daikin FDY "F" Series and FD "F" Series AIR CONDITIONER A hr o C (and other models incorporating BRC1B62/52 Remote Controller) Dear Owner, Thank
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
OPTIONAL SLENDER REMOTE CONTROL
DAIKIN ROOM AIR CONDITIONER Operation Manual OPTIONAL SLENDER REMOTE CONTROL BRC944A2B READ BEFORE OPERATION Safety Precautions...2 Names of Functions of Parts...4 Preparation before Operation...5 OPERATION
User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler
User Guide and Important Warranty Information Suprima 30L - 100L Wall Mounted Fan Assisted Balanced Flue Gas Boiler These instructions are for use with boilers whose serial numbers end C (or higher) only.
Installation and Service Instructions for use by heating contractor SM1 SOLAR CONTROL MODULE IMPORTANT
Installation and Service Instructions for use by heating contractor Solar Control Module for solar connections to the Vitotronic control SM1 SOLAR CONTROL MODULE Product may not be exactly as shown IMPORTANT
Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Baxi Platinum Combi HE Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house,
Operating instructions
6300 9681 02/2006 GB For the user Operating instructions Logano GE315 Boiler for oil-/gas-fired pressure jet burners Please read thoroughly before use. Operating instructions Logano GE315 Dear Customer,
Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)
Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Luna 3 Comfort Troubleshooting Guide June 2008
Luna 3 Comfort Troubleshooting Guide June 2008 For Technical Assistance Call: (800)461-4657 WARNING! THIS DOCUMENT IS INTENDED ONLY AS AN EDUCATIONAL TOOL This Troubleshooting Guide, and the instructions
REMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
Operating instructions. For the operator. Operating instructions. ecotec plus. Gas-fired wall hung high efficiency boiler GB, IE
Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall hung high efficiency boiler GB, IE Inhaltsverzeichnis Inhaltsverzeichnis 1 Notes on the documentation...3 1.1 Storing
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)
OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F
COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions
COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming
TANKLESS WATER HEATER USE AND CARE MANUAL
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing death, personal injury, or property damage. For Your Safety! Do not store or use gasoline
Operating Instructions Air Conditioner
P07-T10130 Operating Instructions Air Conditioner Indoor Unit CS-F24DD1E5 CS-F28DD1E5 CS-F34DD1E5 CS-F43DD1E5 CS-F50DD1E5 Outdoor Unit Inverter Model (HBE5 Series) CU-YL24HBE5 CU-YL28HBE5 CU-YL34HBE5 CU-YL43HBE5
Heat Pump Water Heater IOM Manual
Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Boiler Preparation, Start-Up and Shutdown
Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.
A Class Air Source Heat Pump User Guide
A Class Air Source Heat Pump User Guide IMPORTANT THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLATION 8/60476/0 Issue 1.03 Contents 1: Introduction 1 2: How the Heat Pump Works 1 2.1 Tips and advice
Owner s Manual 58HDX UPFLOW / HORIZONTAL / DOWNFLOW HIGH EFFICIENCY GAS FURNACE. ama ! WARNING SAFETY CONSIDERATIONS
UPFLOW / HORIZONTAL / DOWNFLOW HIGH EFFICIENCY GAS FURNACE Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: Please read all instructions in the manual and retain
AIR CONDITIONER Duct Type OPERATING MANUAL
AIR CONDITIONER Duct Type OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE P/N9374379460 CONTENTS SAFETY PRECAUTIONS... 1 FEATURES AND FUNCTIONS... 3 NAME OF PARTS... 4 PREPARATORY OPERATION... 5
Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.
Battery-Powered Mower NEUTON 24-Volt Charger Instructions Booklet Dear Neuton Owner, In order for you to get the most out of your Neuton Mower, we recently reviewed and revised our battery-charging instructions.
Air Conditioning System
Owner s Information Manual Air Conditioning ystem NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the space provided. This information,
Product and Safety Information... 2,3 Service and Maintenance Munchkin Operation Primary Water
User Manual TABLE OF CONTENTS Product and Safety Information............................................. 2,3 Service and Maintenance Munchkin Operation Primary Water Section I Combustion Air Prevention
Combi 30 HE. User s Guide and Important Warranty Information
User s Guide and Important Warranty Information Combi 0 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents Natural Gas Main Combi
What you can expect from your Solar Hot Water System
Owner s Manual Your Solar Hot Water System Thank you for your investment in the FAFCO Solar Hot Water System. Since 1969 our goal has been to design, test, and produce solar heating systems that save you
SAFEGUARDING THE ENVIRONMENT
SAFETY PRECAUTIONS Do not install the appliance if it is connected to the power supply. The Installation and service/repair must be performed by a qualified technician, in compliance with the producer's
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs, logs are made
USER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Drayton Digistat +2RF
Drayton Digistat +2RF T Programmable Room Thermostat Wireless 24 Hour Model: RF700/22090 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130
Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split
Multi System 16 SEER, Inverter System 9,000 to 18,000 BTU/Hr Single Split 4MXW8-A 4TXM6-A March2013 42 Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex Version C Single, Dual, Tri or Quad Zone Ductless Mini-Split System Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com
Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
VIESMANN. Installation and service instructions VITOTROL 100. for contractors
Installation and service instructions for contractors VIESMANN Vitotrol 100 Type UTDB-RF2 Room temperature controller with digital time switch and wireless receiver For applicability, see the last page
Operating Instructions Air Conditioner
F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Continuous Flow Water Heaters
Operation Manual Continuous Flow Water Heaters For Rinnai continuous flow water heaters manufactured from 2010 onwards (serial number 09.12 xxxxxx) Internal Rinnai continuous flow water heaters must be
Combi Eco Elite Range. User s Guide and Important Warranty Information
User s Guide and Important Warranty Information Combi Eco Elite Range Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents Natural Gas
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK
FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL Thank you for choosing our Air Conditioner. Please read this OWNER'S MANUAL carefully prior to use and keep it for further reference. CONTENTS Contents
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Contact Details. Please note that some of the contact details on this PDF document may not be current.
Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: [email protected]
Combi 24 HE. User s Guide and Important Warranty Information
User s Guide and Important Warranty Information Combi 4 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd 0 Contents
Fuels Safety Program FS- 072-06 7 DIRECTOR S PUBLIC SAFETY ORDER
Ref. No.: Rev. No.: Fuels Safety Program FS- 072-06 7 DIRECTOR S PUBLIC SAFETY ORDER Date: January 13, 2006 IN THE MATTER OF: THE TECHNICAL STANDARDS AND SAFETY ACT, 2000, S.O. 2000, c. 16 - and - ONTARIO