Service/Part Manual. Self-Contained Electronic Ice Maker A Version: Scotsman-webshop.nl
|
|
|
- Jonah Thomas
- 9 years ago
- Views:
Transcription
1 Service/Part Manual Self-Contained Electronic Ice Maker A Version:
2 - 1 - Content Table of Contents Ice Maker Instruction 2-3 Product Specifications Introduction 4 Unpacking and Inspection 4 Location and Levelling 4 Electrical Connections 4 Water Supply and Drain Connections 4 Final Check List 5 Page Operating Inspection Start Up 6 Operating Inspection 6-7 Principle of Operation Freezing Cycle 8 Defrost cycle 8-9 Components Description Circuit Diagram 13 Adjustment Ice Cube Thickness Adjustment 14 Water Drain Adjustment 14 Water Level Adjustment 14 Maintenance and Cleaning General Ice-making System Maintenance Description 15 Water System Cleaning 15 Fault Analysis Fault Analysis Form 1 16 Fault Analysis Form 2 17 Service Spare Parts Sketch and List Frame Assembly Refrigerating system (air cooled type) Component List Water system PC Board Control System B1-B2 B3-B4 B5-B6 B7
3 - 2 - Ice Maker Instruction BL Series Electronic Ice Maker Important Operating Requirements Air temperature Water temperature Water pressure MIN. MAX. BL105 Making Capacity Voltage variations from voltage rating specified on nameplate BL75 Making Capacity ambient temperature ice produced per 24 hrs ambient temperature ice produced per 24 hrs water temperature BL55 Making Capacity water temperature ambient temperature ice produced per 24 hrs BL45 Ice Making Capacity water temperature BL25 Making Capacity ambient temperature ice produced per 24 hrs ambient temperature ice produced per 24 hrs water temperature water temperature Notes: With the unit is inside the cabinet, the ice production is gradually reduced in respect to the levels shown in the graph, up to a maximum of 10% at room temperatures higher than 32(90). The daily ice-making capacity is directly related to the condenser inlet air temperature, water temperature and age of the machine. To keep your ice maker at peak performance levels, periodic maintenance checks must be carried out as indicated on this manual.
4 - 3 - Product Specifications Left View Rear View 20mm outflo w drain 3/4 water inlet cord set Model Unit Front View Total height (with legs) Dime nsions Net weight Gross weight Model Type of Condensation External Surface Bin Capacity Power Supply Electric Current Starting Current Connection Size Air cooling Epoxy resin powder injection housing Model Power of Compressor Water Demand Fuse Power Electricity Consumption
5 A. Introduction This manual provides the specifications and the step-by-step procedures for the installation, startup and operation, maintenance and cleaning for the SCOTSMAN BL5 series icemakers. These icemakers are strictly designed and manufactured by strict control of process. Their ice making systems are thoroughly tested providing the utmost in flexibility to fit the needs of a particular user. These products are designed in strict accordance with the safety requirement and performance standard. To retain the safety and performance built into this icemaker, it is important that installation and maintenance be conducted in the manner outlined in this manual. B. Unpacking and Inspection 1. Call your authorized SCOTSMAN Distributor or Dealer for proper way of installation 2. Visually inspect the exterior of the packing and skid. Any severe damage noted should be reported to the delivering carrier and a damage claim form filled in subject to inspection of the contents with the carrier s representative present. 3. a) Cut off the wrapping strip securing the carton box to the wood skid. b) Unpack the top of the carton and remove the polystyrene protection sheet. c) Pull out the polystyrene posts from the corners and then remove the carton. 4. Remove the front and back panels of the unit and inspect for any interior damage. Notify carrier and distributor of damage and claim for that as stated in step 2 above. 5. Check that refrigerant lines do not rub against or touch other lines or surfaces, and that the fan blade moves freely. 6. Check that the compressor fits snugly onto all its mounting pads. 7. Remove all internal support packing and masking tape. 8. Use clean cloth to wipe the surfaces inside the storage bin and the outside of the cabinet. 9. See data plate on the rear side of the unit and check that local main voltage corresponds with the voltage specified on it. Incorrect voltage supplied to the icemaker will void your parts replacement program. 10. Take the Manufacturer s registration card out from the inside of the material package and fill in all parts including: Model and Serial Number taken from the data plate. Forward the complete self-addressed registration card to SCOTSMAN after service department. 11. If necessary, install the four legs in the leg support of the unit and adjust them to make the unit level.. C. Location and Levelling Warning: This Ice Maker is designed for indoor installation only. The loss or warranties and claims caused by operation at temperatures exceeding the following limitations will be out of the range of terms of the SCOTSMAN Manufacturer s Limited Warranty. 1. Select installation position. Criteria for selection of location include: a. Room temperatures: Minimum temperature 10 (50) Overview and Installation Maximum temperature 40 (100 ). b. Water inlet temperatures: Minimum temperature 5 (40 ); Maximum temperature 35 (90 ) c. Well ventilated location for air cooled ice makers. d. Working Place: Leave sufficient space helpful to carry out installment and maintenance. Leave at least 15cm (6") space at all sides of the unit to ensure ventilation and condensation effect of the air cooling ice maker. 2. Level the unit in both the left to right and front to rear directions. 3. Guarantee repair will be provided by the authorized distributor where you bought the ice maker. Refer to the Warranty for details. Use standard part for part replacement. D. Electrical Connections See data plate for current requirements to determine wire size to be used for electrical connections. All SCOTSMAN icemakers require a solid earth wire. All SCOTSMAN ice makers are supplied from the factory completely pre-wired and require only electrical power connections to the wire cord provided at rear of the unit. Make sure that the ice machine is connected to its own circuit and individually fused (see data plate for fuse size). The maximum allowable voltage variation should not exceed -10% and + 10% of the data plate rating. Low voltage can cause faulty functioning and may be responsible for serious damage to the overload switch and motor windings. All external wiring should conform to national, state and local standards and regulations. Check consistency between voltage on the line and the ice maker s data plate before connecting the unit (power supply). E. Water Supply and Drain Connections General When choosing the water supply for the ice maker, consideration should be given to: a. Length of run b. Water clarity and purity c. Adequate water supply pressure Since water is the most important single ingredient in producing ice you cannot ignore three items listed above. Water pressure below 1 bar (14psi) may cause malfunction of the ice maker. Water containing excessive Minerals will tend to produce cloudy ice cubes, plus scale build-up on parts of the water system. Water Supply Water supply-air cooled ice maker Connect the 3/4" male thread connector of water inlet solenoid valve with supply line connector and install a water supply valve in an accessible position between the water supply line and the unit. If water contains a high level of impurities, it is advisable to consider the use an appropriate water filter or treatment facility.
6 Water Drain The recommended drain tube is a plastic or flexible tube with 18 mm (3/4") I.D. which runs to an open sewer. The water supply and the water drain must be installed to conform to the local code. In some case a licensed plumber or a plumbing permit is required. F. Final Check List Is the unit in a room where ambient temperatures are within a Minimum of 10 (50 ) even in winter months? 2. Is there at least a 15 cm (6") clearance around the unit for proper air circulation? 3. Is the unit level? (IMPORTANT) 4. Have all the electrical and plumbing connections been made, and is the water supply valve open? 5. Has the voltage been tested and checked against the data plate rating? 6. Has the water supply pressure been checked to ensure a water pressure of at least 1 bar (14 psi). 7. Check all refrigerant lines and conduit lines to guard against come-off by vibrations and possible damage. 8. Have the bolts holding the compressor down been checked to ensure that the compressor is snugly fitted onto the mounting pads? 9. Have the bin liner and cabinet been wiped clean? 10. Has the user been given the Manual and been instructed on the importance of periodic maintenance checks? 11. Has the Manufacturer s registration card been filled in properly? Check for correct model and serial number against the serial plate and mail the registration card to the factory. 12. Has the user been given the name and the phone number of the authorized SCOTSMAN Service Agent? 1. Hand shut-off valve 2. Water filter 3. Water supply line (flexible hose) 4. 3/4" male fitting 5. Vented drain 6. Open trapped vented drain 7. Drain fitting 8. Main switch 9. Power line Warning: This icemaker is not designed for outdoor installation and will not function in ambient temperatures below 10 (50 ) or above 40 (100 ).The icemaker will malfunction with water temperatures below 5 (40 ) or above 35 (90 ).
7 Operating Inspection Start Up After having correctly installed the ice maker and completed the plumbing and electrical connections, perform the following Start-up procedure. A. Connect the main power switch and start the unit. Every time the unit returns under power after having been switched off, the water supply valve, defrost valve, water pump and the water drain valve get energized for a period of 3 Minutes, thus to admit new water to the machine sump reservoir to fill it up and eventually, to wash-off any dirt that can have deposited in it during the unit off period. B. During the cleaning operation, check and see that the incoming water flows through the inlet pipe above the sump reservoir into the drain line. During the water filling phase the components energized are: Water inlet solenoid valve Defrost solenoid valve Water drain solenoid valve Water pump If within 3 Minutes of the water filling phase, the machine sump reservoir does not get filled with water from the inlet pipe, it is advisable to check: 1. The water pressure of the water supply line that must be at least 1 bar (14 psi). Max 5 bar(70 psi). 2. The filtering device installed in the water line that may reduce the water pressure below the Minimum value of 1 bar (14 psi). 3. Any clogging situation occurs to the inlet water strainer and/or the flow controller of the inlet valve. C. At completion of the water filling phase, the unit passes automatically into the freezing cycle with the start up of: compressor, while water level of the water tank get into the control state. The water pump started to work 40 seconds after the startup of compressor. Fan Motor (air cooled model) is controlled by the temperature sensor of the condenser. Operating Inspection D. Install, if required, the refrigerant service gauges on both the high voltage side and low voltage side to check discharge and suction pressures of the compressor. (Only applicable to ice maker with service valve) BL series are the ice maker series with no service valve. If the user need ice maker with service valve, describe when ordering from the sales department of our company. E. Check to see the front face of the evaporator that the spray system is correctly seated and that the water jets uniformly reach the surface of the evaporator, and also make sure that there is no excessive water spilling from icesliding plate into ice bin. F. The ice making process takes place with the water uniformly flowing through the surface of evaporator, and end with the molds getting gradually refrigerated by the heat exchange with the refrigerant flowing into the evaporator serpentine. During the freezing process, when the evaporator temperature falls below an established value, the evaporator temperature sensor supplies a low voltage power signal in order to activate an electronic timer. This one takes over the control of the freezing cycle up to the complete formation of the ice cubes. The electronic components in operation during the ice making cycles are: Compressor Water pump Fan Motor (air cooled model) is controlled by the temperature sensor of the condenser. The length of the entire freezing cycle is governed by the temperature sensor installed which is installed on with the evaporator serpentine and the electronic timer (adjustable) installed on the PC board. If room temperature is below 15, the ice making cycle will be shorter (about Minutes). If room temperature is above 30, the ice making cycle will be longer (about Minutes). G. The defrost cycle takes place with the water inlet and water drain valves simultaneously activated. The electronic components in operation during defrost cycle are: Compressor Defrost valve Water drain valve (controlled by PC board and can be set as 3 models: not drain, drain 1 time after 10 cycles and drain 1 time after 30 cycles). Fan Motor (air cooled model) is controlled by the temperature sensor of the condenser. The length of the defrost cycle is automatically controlled by the program of the PC board, depending on the ice required thickness and ambient condition. H. Inspection during defrost cycle Check if the water drain's operation is normal (if water drain function is set), and that water in the sump reservoir is correctly drained. I. Check the texture of ice cubes just released. If it does reach the requirement, some adjustment should be carried out (See adjustment procedure). If the ice cubes are shallow and cloudy, it is possible that the ice maker runs short of water and the quality of the supplied water is not good, requiring the use of an appropriate water filter or treatment unit. J. To be sure of the correct operation of ice level control device, use your hand press the ice sliding plate down which seems the bin is full while the ice cube can not go through the ice sliding plate and fall into the ice bin. After 40 seconds, the unit stops with the Bin Full indicator light on the display plate of PC board. Take hand out to allow the resumption of the ice sliding plate. After 3 Minutes, the ice maker resume its ice making cycle.
8 K. Remove the refrigerant service gauges (if fitted) and refit the unit panels previous removed after adjustment. L. Instruct the user on the general operation of the ice maker and about the cleaning and maintenance.
9 Principle of Operation In the SCOTSMAN ice makers, the water used to make the ice is injected into the spray nozzles by a water pump. After flowing out from a small hole of the spray nozzle, the water flows through the surface of mold cups of the evaporator. A small quantity of the sprayed water freezes into ice; the rest of it flows by gravity into the sump assembly below for recirculation. Freezing Cycle The refrigerant hot gas discharged out from the compressor reaches the condenser where, being cooled down, condenses into liquid. Flowing into the liquid line it passes through the drier filter, then it goes all the way through the capillary tube where, due to the heat exchanging action, it looses some of its heat content so that its pressure and temperature are lowered as well. Next the refrigerant enters into the evaporator serpentine (which has a larger I.D. than the capillary) and starts to boil off; this reaction is emphasized by the heat transferred by the sprayed water. The refrigerant then increases in volume and changes entirely into vapor. The refrigerant vapor then passes through the suction accumulator (used to prevent that any small amount of liquid refrigerant may reach the compressor) at the suction line and flow through the suction line. In both the accumulator and the suction line, it exchanges heat with the refrigerant flowing into the capillary tube (warmer), before to be sucked in the compressor and to be re-circulated as hot vapor. 40 seconds before the start of freezing cycle is pre-cooled area, during which the compressor is running, water pump is not running, fan is funning (controlled by temperature sensor of condenser) and inlet valve is working (controlled by the water-level sensor in the sump reservoir.) The freezing cycle is controlled by the evaporator temperature sensor (which has its probe in contact with the evaporator serpentine) that determines the length of its first portion of the cycle. When the temperature of the evaporator serpentine drops to a pre-set value, the evaporator sensor probe changes its electrical resistance allowing a low voltage current to flow to the PC BOARD which in turn activates an electronic timer. The timer, which is built-in the PC BOARD, is controlled by the evaporator temperature sensor and controls the freezing cycle. The length of the second phase of the freezing cycle is pre-set (can be adjusted by the SIZE electrical potential on PC) and is related to the air temperature. Due to the sensing temperature change of the evaporator sensor, when the electronic timer is working, ice making indicator light on the PC board display-zb green light will be illuminating at the start of ice making and will be blinking at the start of the second phase. If defrost cycle does not start 45 Minutes after the starting of freezing cycle, the unit will automatically identify as freezing overtime and automatically enter into the defrost cycle. If the freezing overtime occurs to the ice maker 10 times in a row (caused by short of refrigerant, abnormal operation of defrost valve, etc.), freezing indicator light-zb green light will be blinking. However it will not stop automatically. At this time, the user needs to disconnect the unit and contact with after service agent. During refrigeration cycle, the pressure range of refrigeration high-pressure end: BL 105/75: 8.5~17bar (119psi~238psi) BL 55/45/25: 7~11bar (98psi~154psi) The pressure of the high-pressure end is controlled by the condensation temperature sensor located at the condenser fin. For air-cooled ice maker, when the condensation temperature senor is higher than the preset limits of condensation temperature, it will feed back to the PC board which will control the operation of fan. Contrarily, when the condensation temperature senor is lower than the preset limits of condensation temperature, it will feed back to the PC board which will control the outage of fan. Notes: If condensation temperature probe sense the temperature is higher than 70(160 F), the unit will stop caused by the startup of protection device, while the R1 and R2 red light will be simultaneously illuminating, warning user of too high condensation temperature. After the condensation temperature is lower than 70 (160 F), remove the power plug before the unit restart, and plug in the plug after waiting 3 Minutes. After 3 Minutes of water injection, the ice maker is working normally. Reasons for abnormal operation as follows: Condenser is clogging Air temperature is higher than 40 (100 F) To avoid abnormal operation and risk of the unit, the user should cut off the power upon one of the above reasons. At the start of freezing cycle, pressure of refrigeration suction end or low-pressure end rapidly is rapidly reduced to: BL 105/75/55/45/25: 0.7~1.8bar (9.8psi~25.2psi) The pressure will be gradually reduced as the ice thickness increases. When the ice cube is completely formed in the ice cup, pressure reaches: BL 105/75: 0.2~0.8bar (2.8psi~11.2psi) BL 55/45/25: 0.01~0.8bar (0.14psi~11.2psi) Overall length of freezing cycle is between Minutes. Defrost cycle The defrost cycle starts after the completion of second phase of the freezing cycle by electronic time control system. Refrigerant hot gas discharged from the compressor flows into the evaporator serpentine though defrost valve. Refrigerant circulated in the evaporator serpentine heats the mold cup to melt the ice cube. Ice cube fall off from the mold cup, into declining ice sliding plate by gravity and finally fall into the ice bin. Defrost indicator light TB yellow indicator is illuminating at the start of defrost. After the end of defrost cycle, hot gas valve, drain valve (equipped as per PC board) closed. The unit starts its new ice making cycle.
10 Operation Features Ice making cycle Average discharge pressure: BL105/75: 8.5~15bar(119psi~210psi) BL55/45/25: 8.5~10bar(119psi~140psi) Suction pressure at the end of ice making BL105/75: 0.2~0.8bar(2.8psi~11.2psi) BL55/45/25: 0.01~0.8bar(0.14psi~11.2psi) Refrigerant flow control (throttling) device Capillary tube Refrigerant injection quantity Refrigerant type: R134a Injection quantity: BL105/BL75: 450g BL55: 310g BL45: 290g BL25: 260g
11 Components Description A. Evaporator Temperature Sensor The evaporator sensor is located at the outlet of the serpentine. During freezing cycle, the temperature of the evaporator serpentine is converted into electric signal, which is transmitted to the PC board. The PC board controls the time of the first phase of freezing cycle based on the electric signal received. The time of the second phase is pre-fixed through adjusting the potentiometer according to the ambient temperature and the ice thickness. B. Condenser Temperature Sensor The condenser temperature sensor probe, located in the condenser fins, detects the condenser temperature variations and signals them to the PC board. In case the condenser temperature probe detects that the condenser temperature is above 70 (160), the PC board will stop the operation of the machine immediately. C. Ice Bin Full Controller The ice full controller is divided into two parts: one part is a magnet injected in the ice slide plate, and the other part is a sensor, which is installed on the plastic frame of the evaporator. In case the ice chute is not re-set and the magnetism is not sensed by the magnetic sensor within 40 seconds, it means that the ice cubes made in the last freezing cycle cannot drop into the ice storage bin, the ice storage bin is full and the Bin Full BM Red LED indicates. When the ice in the storage bin is taken out or moved, the ice chute is re-set, the magnetic sensor detects the magnetism, the state of ice bin full is released and enter into the freezing cycle. If the state of ice bin full is released within 3 minutes, the Bin Full BM Red LED blinks, 3 minutes later enter into freezing cycle automatically. If the state of ice bin full is released at the time of more than 3 minutes, the machine will enter into freezing cycle upon it is started. D. Water Level Sensor The water level sensor is located at the top of the water tank. When water level reaches a certain level during water filling, the magnetic sensor of the water level sensor detects the magnetism and signals it to the PC board. Upon receiving the signal, the PC board powers off the water inlet valve and water filling is stopped. The water level sensor is installed on the support of water level sensor and can be adjusted. When the water level in the water tank is considered to be too low and cannot supply enough water needed for one freezing cycle, the position of the water level sensor can be adjusted higher. When the water level in the water tank is considered to be too high and water overflows whenever water is filled, it is means that the water level sensor cannot control the water inlet valve, the position of the water level sensor can be adjusted lower. If the position of the water level sensor is adjusted low and the problem is not solved, it means that the water level sensor is failure and should be replaced. E. Name and Meaning of LED and Push Button LED on the over plate of the PC board BM Ice bin full LED ZB Ice-making LED TB Defrosting LED SW Water level LED R1 Water-Lacking LED R2 High temperature alarm LED MODE State adjustment mode key The functions of the Mode key: Power up / filling water/pre-cooling/ice-making/defrosting/ice bin full detecting. Press it each time, it enters into the next state. Only professional maintenance personnel are allowed to press the MODE key. F. PC Board (Data processor) The PC board, fitted in its plastic box located in the front of the unit, consists of one power-in high voltage transformer, one PC board with both high and low voltage and a display panel connected with the PC board. The PC board is the brain of the ice maker, through its micro processor, the signals received from the four sensors in order to control the operation of the different electrical components of the ice maker (such as compressor, Fan, defrosting valve, water inlet valve, drain valve, water pump).
12 Condenser sensor Evaporator sensor Water level switch Pressure switch shor-circuit Printed Circuit Board (PCB) 6 Water drain valve 5 Water inlet valve 4 Fan 3 Water pump 2 Defrost valve 1 compressor Ice thickness thick detection mode jumper wire Ice thickness adjustment potentiometer Drain jumper wire State adjustment MODE Ice bin full sensor BM: Ice bin full LED (red) ZB: Ice-making LED (green) TB: Defrost LED (yellow) SW: Water level LED (white) R1: Water-lacking LED (red) R2: High temperature LED (red) State adjustment Fuse Fuse Transformer G. Vertical Type Water Spray System The water pump spray out the water sucked from the water tank. The water flow into the spray tube through the PVC tube, then pass the pinholes on the water tube, and then flow evenly through the ice module of the evaporator, thus ice cubes are made. It is cycled continually. H. Vertical Type Water Spray System The water pump spray out the water sucked from the water tank. The water flow into the spray tube through the PVC tube, then pass the pinholes on the water tube, and then flow evenly through the ice module of the evaporator, thus ice cubes are made. It is cycled continually. I. Vertical Type Water Spray System The water pump spray out the water sucked from the water tank. The water flow into the spray tube through the PVC tube, then pass the pinholes on the water tube, and then flow evenly through the ice module of the evaporator, thus ice cubes are made. It is cycled continually. J. Water pump The water pump operates continually throughout the freezing cycle and keeps water flowing continually through the ice module of the evaporator and produces ice cubes. Recommendation: The water pump should be checked at least every 3 months. K. Water Inlet Solenoid valve - 3/4" Male Fitting The water inlet solenoid valve is located on the up and down water support. The incoming water is controlled by the PC board, among which one water flow controller is used to control the water flow incoming the water tank per unit time. L. Defrost Solenoid Valve The defrosting solenoid valve, located at the hot gas bypass pipe, is consisted of two parts of valve body and coil. During defrosting and water filling phase, operation is controlled by the PC board.
13 During the defrost cycle, the defrost solenoid valve is energized and sucks the push rod of the valve body in order to let the hot gas discharged from the compressor to flow directly into the evaporator pipe to melt the formed ice cubes. M. Fan The Fan is controlled through the PC board to draw cooling air through the condenser fins, thus lower discharge temperature of the compressor. Normally it operates at intermittence only during the freezing phase to keep the condenser pressure between two corresponding pressure values. N Compressor The hermetic compressor is the heart of the refrigerant system of the ice maker and it is used to circulate and retrieve the refrigerant throughout the entire system. It compresses the low pressure refrigerant vapor causing its temperature to rise and become high pressure hot vapor which is then released through the discharge valve. O. Water Drain Solenoid Valve The water drain solenoid valve is controlled by the PC board. (no water drain, drain after 10 freeze cyeles and after 30 freeze cycles) Based on the different configuration of the PC board, it starts operating for 2 minutes so that all remaining water containing minerals in the water tank drains out.
14 Circuit Diagram BL 105/75/55/45/25 6 Drain valve 5 Water inlet valve 4 Fan 3 Water pump 2 Defrost valve 1 Compressor Water level switch Pressure switch shor-circuit Condenser sensor Evaporator sensor Printed Circuit Board (PCB) Thick Ice bin full sensor State adjustment MODE R: Red W: White O: Orange P: Pink GR: Gray BK: Black BL: Blue BR: Brown G/Y: Kelly BM: Ice bin full LED (red) ZB: Ice-making LED (green) TB: Defrost LED (yellow) SW: Water level LED (white) R1: Water-lacking LED (red) R2: High temperature LED (red) State adjustment MODE: Power up/filling water/pre-cooling/ice-making/de-icin g/ice bin full detecting. Press it each time, it enters into the next state Transformer Power 230V QX2 (BH): If the jumper wire plug-in unit is located at this position, the controller executes the ice thickness detection mode (The ice is detected by the ice thickness detector). QX3 (WK): If the jumper wire plug-in unit is located at this position, the controller executes the ice thickness detection mode (The ice is detected by the ice thickness detector, which is pre-set at the factory.) QX1: The 0 position represents that no auto water drain function is available. The 10 position represents that water drain is done automatically every 10 cycle. The 30 position represents that water drain is done automatically every 30 cycle. The factory pre-set position is B Ice thickness adjustment (size): To make ice cubes thicker, adjust it clockwise.
15 Adjustment Procedure 1. Ice Cube Thickness Adjustment The ice-maker is adjusted to the best state at the factory. Usually users do not need to adjust it any more. If it really needs adjustment, adjust the SIZE potentiometer on the PC board to change ice cube thickness. To make ice cubes thicker, turn it clockwise. To make ice cubes thinner, turn it counter-clockwise. If adjust the SIZE potentiometer, do not adjust too much, adjust it about 15 degree every time. If ice cube thickness still cannot reach the required thickness after the completion of three cycles, adjust it one more time. Adjust it several times repeatedly, the satisfied ice thickness can be obtained. 2. Water Drain Adjustment The frequency of water drain of the ice-maker should be adjusted based on the water quality. After the short circuit plug-in unit is plugged in the QX plug-in unit of the PC board, no water drain, water drain once after 10 freezing cycles and water drain once after 30 freezing cycles can be selected. Recommendation: It is recommended that the water drain configuration is set for water drain after 10 freezing cycles to obtain clearer ice cubes and keep the water tank clean. 3. Water Level Adjustment The water level in the water tank can be adjusted by the water level sensor to obtain the best water level to achieve the best ice-making effect. After the support of the water level sensor is adjusted, should fasten the screws. It is set to the best position at the factory. Do not adjust it unless it is really necessary.
16 Maintenance and Cleaning A. General The periods and the procedures for maintenance and cleaning can be changed. Cleaning, especially, will vary depending upon local water and ambient conditions and the ice volume produced. Each ice maker must be maintained individually in accordance with it particular location requirements. B. Ice-making System Maintenance Description The following maintenance should be scheduled at least two times per year on these icemakers. 1. Check and clean the water line strainer. 2. Check that the icemaker is leveled in side to side and in front to rear directions. 3. Use special icemaker cleaning liquid to clean water system, evaporator and Ice bin. Reference to procedure C (Description of Cleaning), cleaning frequency and procedure should be decided based on the local conditions. Cleaning should be varied according the local water quality and the operating condition of each icemaker. Check frequently cleanliness of ice cubes and the components of the water system before and after cleaning to determine the cleaning frequency and procedures needed. 4. When air cooled icemaker stops, use cleaner, small hair brush or non-metal brush to clean condenser. Avoid to damage the condenser and condenser temperature sensor. 5. Check for water leaks and tighten drain line connections. Pour water down bin drain line to be sure that drain line is open and lean. 6. Check size, condition and texture of ice cubes. Perform adjustment of cube size control as requidred. 7. Check for refrigerant leaks. C. Water System Cleaning 1. Remove the front and top panels to gain access either to the control box and to the evaporator. 2. When the defrost cycle is completed, unplug the power plug. Cleaning 3. Prepare cleaning solution special for icemaker in a plastic container. Warming: Before opening cleaning solution, must check the instruction of the cleaning solution in order to avoid damage. 4. Scoop out all the ice cubes stored into the bin in order to prevent them from being contaminated with the cleaning solution, then remove the erect overflow pipe to let water outflow from the water tank (remember to insert the overflow pipe back). 5. Use a brush to take some cleaning solution to dissolve the impurity material on the ice module of the evaporator and clean scale deposit. 6. Plug in the power plug, let the machine remain in the Cleaning mode for about 3 minutes. And then unplug the power plug. 7. Then remove the erect overflow pipe (remember to insert the overflow pipe back) to let water outflow from the water tank. Then pour clean water into the water tank. Remove the water spray pipe and the water tank to wash them separately (if necessary). 8. Plug in the power plug again. Follow steps 6 and 7, use clean water to circulate to clean the whole water system. If necessary, clean more than one time. 9. Unplug the power plug, release the water used in the water tank, and then plug the power plug again. The icemaker starts freezing cycle. Sanitation 10. Prepare a plastic container, use warm water of ( ) to dilute the cleaning solution. Warming: Never mix the cleaning with the sanitising solution. 11. Follow procedures of 4-19 to sterilize the water system. 12. Reinstall the front plate and the top panel. 13. At completion of the freezing an defrost cycle, make sure of proper texture and cleaness of the ice cubes and that, they do not have any acid taste. If cloudy and sour ice cubes are available, use hot water to dissolve them and pour them to the safety place appointed in order to avoid eating by mistake which may cause injury. 14. Wipe clean and rinse the inner surfaces of the storage bin. To prevent the accumulation of undesirable bacterial, it is necessary to sanitize every week the interior of the storage bin. Cleaning solution for icemaker has corrosivity. In case it sprays on your mouth, it will burn your mount, care should be taken to avoid cleaning solution to spray. In case cleaning solution sprays on your mouth or eyes, use a lot of water or milk to wash and should go to hospital immediately. When washing the external surface, children are not allowed to close. Cleaning solution should be kept away from children.
17 Fault Analysis Symptom Possible Cause Suggested Correction Unit does not run Abnormal power supply Blown power in fuse in PC board Check power supply voltage, if no voltage, check power supply line Check power supply voltage, if it is low, contact power supply company Replace the fuse. If the fuse is broken again, check the cause. The machine is stopped abnormally (such as high temperature protection) Press the MODE key on the PC board to reset, the machine starts or starts automatically 2 hours later or unplug the power plug, plug it again 3 minutes later, the machine starts. At the state of ice bin full Adjust the position of the ice cubes in the storage box to let the ice chute reset and then start the machine Water supply abnormal See the processing method for water-lacking Compressor intermittently cycles Low votage Non-condensable gas in system Compressor starting device with loose wires Mechanical problem Check circuit for overloading Check power supply voltage, if it is low, contact power supply company Purge the system Check for loose wires in starting device Replace compressor Cubes too small Freezing cycle too short Capillary tube partially restricted Moisture in the system Shortage of water Shortage of refrigerant Check the PC board setting Purge the system Same as above See the processing method for water-lacking Check for leaks in the refrigerating system & recharge Cloudy ice Shortage of water Dirty water supply Accumulated impurities See the processing method for water-lacking Use water softener or water filter Clean as per cleaning procedure Shortage of water Water spilling out through ice chute Water inlet solenoid valve not opening Water leak in water tank Water inlet valve flow control plugged Leak of water drain valve Tighten the screws on the clamping plate of the PVC pipe to reduce water fitting Check, if damage, replace it Check for the leaking points and repair it. If necessary, replace it. Replace the water inlet valve Check, if damage, replace it
18 Fault Analysis Symptom Possible Cause Suggested Correction Irregular cubes size & some cloudy Some jets plugged Shortage of water Unit unlevel Clean the jet See the processing method for water-lacking Level as required Decreased ice capacity inefficient compressor Leaky water valve or Water filling pipe or small holes of jet pipe plugged Non-condensable gas in system Bad ventilation Capillary tube partially restricted Defrost valve leaking Shortage of refreigerant Shortage of refrigerant Discharge pressure too high or too low Defrost valve plugged or not openning Replace compressor Check, if damage, replace it Check, if blocked, unblock it. Purge the system Rotate again or improve ventilation Purge the system Check, if damage, replace it Change filling volume, release slowly As per the mark on the nameplate, purge it. Check for the cause of incorrect discharge pressure Check, if damage, replace it Unit won't harvest Inoperative PC board Defrost valve not opening Water inlet solenoid valve not opening Check, if damage, replace it Check, if damage, replace it Check, if damage, replace it Incorrect discharge pressure Inoperative condenser sensor Inoperative PC board Check, if damage, replace it Check, if damage, replace it Excessive water in unit base Water system leaking Check for the leaking points and repair it. If necessary, replace it. Important: The machine should be maintained by authorized professional maintenance personnel. If power supply cord is damaged, it should be replaced by authorized professional maintenance personnel to avoid danger.
19 Frame assembly
20 Frame Assembly Component List Item Name BL105 BL75 BL55 BL45 BL25 1 Bottom plate Leg support Ornamental ring Leg main body Adjustment leg Left side panel Center spacer Ice bin foaming bin assembly Right side panel Front decorating plate Left slide 13 Right slide Front upper beam Door assembly Door guide roller 17 Brand LOGO Model plate Ice bin cover Ice bin isolation Top panel Left plastic corner 23 Right plastic corner Water in-outlet bracket Back plate upper Back plat lower Front pane
21 Refrigerating system
22 Refrigerating System (air cooled type) Component List Item Name BL105 BL75 BL55 BL45 BL25 2 Compressor * Protector * Starting relay * Start capacitor Condenser Blade Fan Mechanical filter Copper tee Defrost valve Capillary tube Accumulator Dry filter Fan bracket J1/J Condenser separator * No mark
23 Water system
24 Water system Component List Item Name BL105 BL75 BL55 BL45 BL25 2 Water Inlet valve Water Inlet tube Water Inlet copper tube Water sump Over flow base PVC tube Water Pump Water Pump bracket PVC tube assembly Water distribute tube Evaporator Ice slide board Over flow tube PVC tube assembly Discharge valve PVC tube Drain T tube Plastic nut Water sensor bracket
25
26 Scotsman Ice Systems (Shanghai) Co., Ltd. 85 YangChuan Rd. JiaDing Industrial Development Region Shanghai, China Postcode: Fax: Telephone: / Website: A
How To Check A Freezer
SERVICE AND INSTALLATION MANUAL ICE UNDERCOUNTER SERIES CUBERS MODEL-ICEU070A Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081374-01 Date10/08 ICEU070A INTRODUCTION This manual
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
F20, F40, F60, F85 & FCI20, FCI30, FCI40 FCI60, FCI85 Cube Ice Maker
F20, F40, F60, F85 & FCI20, FCI30, FCI40 FCI60, FCI85 Cube Ice Maker S e r v i c e M a n u a l Foster Ice Cuber Machine CONTENTS Page 1. General Information and Installation Instructions 2 1.1 Introduction
REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: [email protected] Website: www.centrair.ca
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
CU50 Service Manual Introduction:
Introduction: This ice machine is the result of Scotsman s decades of experience as an industry leader in the design and manufacture of both commercial and residential ice machines. This manual includes
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
Compressor Service & Maintenance Manual
Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Hoshizaki America, Inc.
Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-1301SAH/3, SWH/3, SRH/3 KM-1400SWH-M, SWH3-M KM-1601SAH/3, SWH/3, SRH/3 KM-1900SAH/3, SWH/3, SRH/3 KM-2100SWH3, SRH3 KM-2500SWH3, SRH3 KMH-2000SWH/3,
AC 45 AC 55 AC 85 AC 105 AC 125 AC 175 AC 225
Page 1 Page 1 SERVICE MANUAL AC 45 AC 55 AC 85 AC 5 AC 125 AC 175 AC 225 Electronic cubers with storage New PC Board version MS 00.81 REV. 07/2002 Page 2 Page 2 INDICE Table of contents Specifications
PC1130 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
COMPRESSED AIR DRYER
COMPRESSED AIR DRYER Model 40211 ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2002 by Harbor Freight Tools.
ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t. www.ice-air.com
80 Hartford Avenue Mount Vernon New York 10553 Tel: 914-668-4700 EXT. 203 Fax: 914-668-5643 www.ice-air.com Wo r l d C l a s s C o m f o r t Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE
PC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100] PLEASE READ BEFORE INSTALLATION TO PREVENT DAMAGE TO THE COOLER HOT WATER TANK STEAM EXAUST VENT (CAUTION!)
Table Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps Troubleshooting Submersible Pumps Fuse overload or circuit breaker trips when motor is started 1. Incorrect line voltage. Check the line
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
800-292-3279 916 638-0828
800-292-3279 916 638-0828 http://easycleansystems.com/heaters/heater-parts.html VAL6 KBE5S and KBE5L Service manual KBE5S 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Heat Pump Water Heater IOM Manual
Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump
SECTION ONE INSTALLATION CONSIDERATIONS
SECTION ONE INSTALLATION CONSIDERATIONS LOCATION The ice maker may be closed in on the top, rear and two sides. The front MUST BE unobstructed for proper air circulation and operation. Installation should
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH
ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH The original design of the 03 Alpine Coaches (and perhaps other years as well) did not include any kind of engine fan engage mechanism
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
Page 1. Page 1 SERVICE MANUAL EC 106 EC 126 EC 176. Electronic cubers with storage
Page 1 Page 1 SERVICE MANUAL EC 106 EC 126 EC 176 Electronic cubers with storage MS 1000.98 REV. 07/2006 Page 2 Page 2 INDICE Table of contents Specifications EC 106 Specifications EC 126 Specifications
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL
BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL Drawing : - TPC337 Issue : - 2 Date : - 24/01/12 UNPACKING Thank you for deciding to purchase an EIPL Industrial dehumidifier. Like the many tens of thousands
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
Nexus FS Point of Use Installation Guide
Nexus FS Point of Use Installation Guide Nexus FS POU Install Guide:12152011:rev-12152011 Technical Specifications Dimensions: Height: 43.5 Width: 11.65 Depth: 15 Weight: 34.39 LBS Electrical Specs: Voltage:
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
Geyser-R Heat pump water heater Installation manual
Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed
Miami Heat Pump HP Series Installation Guide
CAUTION- THIS UNIT IS FOR INDOOR USE ONLY!! WARNING BEFORE ANY INSTALLATION OR MAINTANCE IS STARTED PLEASE READ COMPLETE INSTLLATION GUIDE. INSTALLATION START-UP AND SERVICE INSTRUCTION- The HP Water Source
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
ON-VEHICLE INSPECTION
Sight Glass I11244 ONVEHICLE INSPECTION 1. INSPECT REFRIGERANT VOLUME Observe the sight glass on the liquid tube. AC3 AC22F05 Test conditions: Running engine at 1,500 rpm Blower speed control switch: HI
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)
OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12) Revision 1.0 Page 1 of 50 THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE SOLE PROPERTY OF INTERNATIONAL THERMAL RESEARCH, LTD. ANY REPRODUCTION
WALL MOUNTED SPLIT TYPE AIR CONDITIONER
WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
Not required for most applications Not required for most applications High pressure (12-803 provided) High pressure (12-803 provided)
ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 712-802-1, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-803, 12-501, 12-804, 12-500, & 15812NOS Installation Instructions THESE INSTRUCTIONS
WINDOW ROOM AIR CONDITIONER
WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please
floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL
floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL WHAT IS AN ECO AIR COOLER? The ECO AIR COOLER uses evaporative cooling to provide an airflow that is cooler than the
HEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
MDT5N25 & MTD5N40 SERVICE PARTS
MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts
Thermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.
Pellet Heater Owner's Manual Installation and Operating Instructions Please read this entire manual before installation. Save these instructions. SAFETY NOTICE HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED
Water Tec of Tucson Water Systems
Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment
Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine
Installation Guide 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Table of Contents Warnings & Important Safety Instructions 3 Dimensions (Professional) 5 Dimensions (Custom Panel) 6 Specifications
OWNER S Manual PRINTED IN CANADA 10/2009
OWNER S Manual PRINTED IN CANADA 10/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing
USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172
Model # 900172: Page 1 USER MANUAL Bottom Loading Bottled Water Dispenser Model # 900172 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING
Engineering Recommendation on: Accumulators Revised 6-17-99 Issued January 10, 1979 Page 1 of 7
Issued January 10, 1979 Page 1 of 7 Accumulators have long been recognized by the industry as an effective means of maintaining good system balance by storing excess refrigerant as the condenser or evaporator
PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/
CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
MP-4000 Alarm List (Software version 2.4.3 or later)
Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
User's Manual for Residential Ice Machine Model DCE33
User's Manual for Residential Ice Machine Model DCE33 INTRODUCTION The Scotsman DCE33 is a restaurant type ice machine designed for home use. It produces the same high quality ice as large Scotsman commercial
OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)
OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F
Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.
R Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL for SPLIT SYSTEM Bus Air Conditioning Units T--326 Rev -- OPERATOR S MANUAL BUS AIR CONDITIONING UNITS GEN IV & GEN V CONTENTS
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.
High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output. Modular Design for Easy, Cost Effective Maintenance. Standardized Interface Allows Interchangeable Control Modules
NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS
INFORMATION INFORMATION ON THE TECHNOLOGY The -Frost refrigerators are different from the other static refrigerators in terms of their operational system. In normal refrigerators, in the freezing section,the
AFE424 SERVICE PARTS
This is the parts list for the AFE. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
Line to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101 By Jim VanderGiessen Jr, Pro Refrigeration Inc. There is a good chance your glycol chiller system is often completely forgotten about, until that dreaded day you
ALL IN ONE. Heat Pump Water Heater
ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------
Taurus Series YORK Window Air Conditioners
Taurus Series YORK Window Air Conditioners IOM IOWRCAG50220711A1 Warning 1. Before using the Air conditioner please read the instructions carefully. They contain important advise about the installation,
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
BERMAD Fire Protection
400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad
