RF SAFETY CATALOG EMF MEASUREMENT AND MONITORING TOOLS
|
|
|
- Darren Stewart
- 9 years ago
- Views:
Transcription
1 RF SAFETY CATALOG EMF MEASUREMENT AND MONITORING TOOLS
2 Quick Guide of MVG's RF Safety Solutions System name EME Guard XS EME Guard FlashRad EME Spy 200 INSITE Free Product range Worker Safety Worker Safety Worker / Public Safety Public Safety Public Safety Key feature Accurate measurement with Tri-axis isotropic sensor Preset Alarm threshold Affordable solution Accurate measurement with Tri-axis isotropic sensor User definable alarm thresholds Data storage Software Real time transmission of the measurement Broadband sensor Cover frequencies of all cellular networks including short pulsed signals Dedicated software for FlashRad network management Frequency selective portable system Independent measurement on Uplink and Downlink for cellular network bands Real time monitoring on PC or Smartphone (Android Application) Frequency selective system for in-situ spot measurement Compatible with most spectrum analyzers available on the market Fully automatic measurement process Utilisation mode Portable Portable Stationary Portable Portable Selectivity Broadband Broadband Broadband Selectivity per services Selectivity per channel Frequency bands 80 MHz to 6 GHz 27 MHz to 40 GHz Probe dependent: 900 MHz to 11 GHz 700 MHz to 6 GHz 700 MHz to 3 GHz 20 selected frequency bands from 88 MHz to 5850 MHz 100 KHz to 6 GHz Audio alarm Visual alarm Monitoring Data storage Software NA EME Guard Analysis FlashRad software EME Spy Analysis INSITE Free software Industries/ Users Antenna installer & maintenance companies Operators (cellular network, broadcast, PMR, radar, ) Military/Defense RF laboratory workers Local and national authorities Antenna installer & maintenance companies Operators (cellular network, broadcast, PMR, radar, ) Military/Defense RF laboratory workers Military/Defense Telecom Regulators RF laboratory Local and national authorities Operators (cellular network, broadcast, PMR, radar, ) Local and national authorities Telecom Regulators Research agencies, R&D labs, universities RF laboratory workers Real estate pre certification Certification agencies Telecom Regulators Operators (cellular, network, broadcast, PMR, radar, ) Research agencies, R&D labs, universities Military/Defense Page P 8 P 10 P 13 P 18 P 21 2 MVG 2015 Product specifications and descriptions in this catalog are subject to change without notice. Actual products may differ in appearance from images shown.
3 The Smart Choice for RF Safety Since its creation in 1986, Microwave Vision Group (MVG) has developed a unique expertise in the visualization of electromagnetic waves. The Group's mission is to extend this unique technology to all sectors where it will bring strong added value. Year after year, the Group develops a complete range of Radio Frequency (RF) instruments to measure the level of exposure to the electromagnetic field and to address the following needs: To continuously record the electromagnetic field level and alerts the user to potential overexposure To monitor actual levels and compare them to the regulatory limits To address public concern through appropriate communication To simulate EMF radiation in real environments 3
4 Why do we measure exposure levels? Electromagnetic fields are increasingly present in our living environment. For this reason they arouse ever more concern and raise questions about the possible harmful effects of these fields on health. As part of its public heath charter and in response to growing concerns, the World Health Organization (WHO) introduced the International Electromagnetic Fields Project in This Project aims to assess the health and environmental effects caused by static or variable electric and magnetic fields in frequencies from 0 to 300 GHz. Wherever there is electricity (voltage or current), there is electromagnetic field (EMF). All types of wireless transmissions (radio/tv broadcasting, voice/data wireless communication) use electromagnetic fields. The generated field propagates in the form of waves and is all around us even if we cannot see it or hear it. The electromagnetic field has two components: the Electric E Field and Magnetic H Field, and they are proportional to each other in far field measurement. H ICNIRP - Reference levels for exposure to electric fields Field (V/m) [logarithmic scale] E Occupational Wave length Frequency (MHz) [logarithmic scale] General public Z BASIC RESTRICTIONS AND REFERENCE LEVELS To protect individuals from the potential health effects of radio waves, protection levels known as basic restrictions were recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP - icnirp.org). The ICNIRP is the non-governmental organization officially recognized by the WHO and the International Labor Organization (ILO) in the field of Non-Ionizing Radiation. These basic restrictions were established based on published biomedical studies and relative to the health effects of electromagnetic waves. In the area of high frequencies, they are expressed in terms of Specific Absorption Rate (SAR) and the biological effects appear above 4 Watts per kilogram for the entire body (increase in body temperature of more than one degree) and above 100 watts per kilogram locally. The basic restrictions are set so as to take into account uncertainties related to personal sensitivity, environmental conditions and diversity in the age and state of health of the populations concerned. The protection levels for workers were established at one tenth of these exposure levels producing an impact, and fifty times lower for the general public. For the general public, the basic restrictions thus require that the power absorbed per kilogram (SAR) be at 0.08 W/kg maximum for the entire body and 2 W/kg maximum for 10 grams of tissue. Given the complexity of measuring the SAR in situ, the ICNIRP (based on the studies carried out to find the relation between a plane wave power surface density and the power absorbed by an ellipsoid representing a human body) has defined reference levels deduced from basic restrictions and expressed in Volts per meter or Watts per square meter. Compliance with all the recommended reference levels will ensure that the basic restrictions are observed. If the measured values are higher than the reference levels, this does not necessarily mean that the basic restrictions have been exceeded. In this case, check whether these levels of exposure are lower than the basic restrictions. 4
5 REGULATION LINKED TO THE EXPOSURE LEVELS In Europe, the exposure limits follow the European Union Council Recommendation 1999/519/CE of July 12 th 1999 regarding the public exposure to electromagnetic fields. The exposure limit values are revised periodically if needed. The last report from the Scientific Committee on Emerging and Newly Identified Health Risks (SCENIHR), an independent European Commission body, on the health effects of electromagnetic fields, came out in January The conclusions of this report do not challenge the exposure limit values proposed by the above-mentioned European recommendation. The great majority of European Union member countries follow this recommendation either by incorporating it into national regulations (Austria, Czech Republic, Estonia, Finland, France, Germany, Hungary, Portugal, Romania, Slovakia, Spain) or in the form of recommendations (Denmark, Ireland, Latvia, Malta, Netherlands, Sweden, United Kingdom). However, different approaches are applied in certain member states with the introduction of more restrictive limits in "living areas" (Belgium, Bulgaria, Greece, Italy, Lithuania, Luxembourg, Poland, Slovenia). The same goes for Switzerland and Liechtenstein. The values chosen by these States are based on the application of the principle of precaution related to potential health risks related to exposure to electromagnetic fields and the exposure limit values were in most cases set in an arbitrary manner. Concerning workers, as part of the European directive on exposure of workers to the risks arising from electromagnetic fields (directive 2013/35/EU of 26 June 2013), all employers must now determine the exposure (levels, duration), assess risks and take the necessary measures to ensure safety and protect the health of workers from the risks arising from professional exposure to these electromagnetic fields. In particular, they must: measure and/or calculate the electromagnetic field levels to which workers are exposed, via the appropriate departments at regular intervals record the results of this assessment on a reliable medium that can be consulted subsequently Other information concerning the regulation throughout the world may be found directly on the WHO website: Worldmap5.htm. MEASUREMENT PROTOCOLS AND STANDARDS In order to compare the exposure levels measured at the established limits, measuring protocols have been established by the main standardization bodies. Some examples are the ECC/REC/(02)04 recommendation and the EN50383, EN50413, EN50492, EN62311 standards in Europe and the IEEE Std.C95.3 standard in North America. WHY MEASURE ELECTROMAGNETIC FIELDS? Measuring the electromagnetic field is essential to check that exposure levels respect the regulatory limits established in each country, and thus ensure the safety of individuals exposed, whether members of the general public or workers. For individuals who work in proximity to high frequency emmiters, the measurement ensures that the emitter is switched off when the intervention takes place and/or that the electromagnetic fields are well below the recommended levels. It thus reassures these individuals who can then complete their work without worry. The introduction of a Monitoring network on the work site allows this exposure to be constantly monitored. In either case, the measurement allows the employer to check that employees have not been over-exposed during their assignments. Unlike a simulation or calculation, a measurement is concrete. Communicating the measured exposure levels, which are mostly very low as compared to the reference levels, provides reassurance for the concerned public. If the measurement reveals high levels of exposure, it then allows remedial actions to be implemented. Here again, the measurement can be occasional in time and space: an exposure meter can be lent to an administration official, who for a given period can check the levels to which he/she is exposed in the home or workplace, or it can be performed via a Monitoring network, with each probe sending these measurements over time to a database or eventually to a website, which can then be used by the authoroties (muincipality for example) to communicate the overall exposure of a city to the public. The measurement taken by scientists by lending an exposure meter to a representative panel also allows us to find out the average exposure for a given population, and potentially the change in this exposure according to the technology (television broadcast, 2G, 3G, 4G mobile communications, domestic networks). 5
6 6 Finally, the measurements can be used to confirm and/or calibrate a propagation model. An appropriate combination of simulation and measurement allows us to obtain a precise mapping of exposure in a large geographic area, and to monitor changes to this exposure over time, in quasi-real time mode. HOW TO MEASURE EXPOSURE TO ELECTROMAGNETIC FIELDS Exposure to electromagnetic fields is generally measured using a probe and a receiver (Volt meter or power meter). An electromagnetic field probe is an "antenna" that has been optimized to measure exposure to electromagnetic fields. There are two types of probe for measuring exposure to electromagnetic fields: "broadband" probes and "frequency selective" probes. A broadband probe generally comprises a dipole and a diode connected directly between the two poles of the antenna. Using this type of probe, the voltage proportional to the field level is measured. The quality of this type of probe will therefore depend on its ability to provide the same voltage for the same field and regardless of the frequency (frequency is of course within the usage bandwidth) of the field to be measured. These "broadband" probes provide information on the level of exposure, but do not indicate the frequency of the field to which the user is exposed. They are mostly used in warning products (worker exposure meter) or for a quick measurement of compliance when measured levels remain low. This type of probe is defined by its isotropy, its bandwidth, its sensitivity, its measurement dynamic, its frequency flatness and its linearity. The second type of probe, depending on the recevier topology used with it, provides information regarding the frequency and the amplitude of the measured field, as well as information on the level. They are incorporated into more refined compliance or information measuring products. They are defined by their isotropy, their bandwidth, and their antenna gain or factor: the dynamic, sensitivity and linearity in this case are dependent on the receiver topology used with a given probe. Isotropy: The isotropy characterizes the ability of the field measuring probe to always provide the same response to a given field level, regardless of the direction of arrival of this field or its polarizations. It is a parameter required by most of the current measurement standards. There is no single naturally isotropic antenna: for electromagnetic field probes, this isotropy is thus obtained by combining the radiation pattern of three elementary antennae (dipole or monopole) appropriately placed with respect to each other. Bandwidth: The performances of an electromagnetic field measurement probe vary according to the frequency of the field to be measured. They are thus defined to be used over a limited frequency range, known as the usage bandwidth. Sensitivity: The sensitivity of an electromagnetic field measurement probe or system is the minimum level of the field that can be measured with this tool. Dynamic: The dynamic of an electromagnetic field measurement probe or system is the difference between the maximum and minimum field that can be measured with this tool. It is generally expressed in db. Frequency flatness: This parameter characterizes the quality of a broadband probe. It represents the variations of the measured E-field at a fixed frequency, when the level of the E-field is varied over the dynamic range of the probe. Linearity: This parameter characterizes the quality of a broadband probe. It represents the variations in the levels measured, with fixed frequency and making the level of the field measured over the probe's measuring range vary. Antenna Gain and/or Factor: An antenna gain (respectively of an electromagnetic field measuring probe) characterizes its ability to emit (respectively receive) in a specified direction. It is generally expressed in dbi, taking as a reference an isotropic antenna, meaning a fictitious antenna that radiates uniformly in all directions. The gain of this antenna is thus 1, or 0 dbi (dbi for decibel-isotropic). The role of an electromagnetic field probe is to transform the recieved electromagnetic field level into RF power. The antenna factor is defined as the ratio of the electromagnetic field captured by this antenna to the voltage measured at the antenna terminals. AF = E V r The antenna factor (expressed in db) is linked to its gain by the following equation: AF = 20 Log(F) G 29,78 In this equation, F is the frequency in MHz, and G is the gain in dbi. The power received by an antenna capturing an electromagnetic field can easily be found using the following formula: P r = 20 * Log(E) AF + 13 In this equation, Pr is expressed in dbm, E in V/m and the antenna factor in db.
7 Worker Safety 7
8 EME Guard XS + Accurate measurement with tri-axis sensors Instant audio and visual alarm Robust, reliable and user-friendly Main features User profile Persons working near antennas including installation and maintenance workers, broadcast, PMR and mobile phone operators or regulatory body employees Measurement capabilities Continuous monitoring of Electromagnetic Field levels with isotropic tri-axis E-field sensors EMF Level indicated by a LED color scale Audio and visual alarms triggered when EMF exceeds the reference level Frequency bands 80 MHz 6 GHz Safety recommendations ICNIRP FCC Safety Code /35/UE New EU Directive Alarm threshold can be adjusted at MVG factory upon request Product Configuration Equipment EME Guard XS MVG Case Wirst strap Lanyard Connecting adapter Armband 2 x 1.5 V Size N Alkaline batteries Instructions for use Services Initial calibration Additional calibration Extended warranty 8 Included Optional
9 I EME Guard XS TECHNICAL CHARACTERISTICS Probe Frequency range Lower detection limit Upper detection limit Isotropic 3-axes probe 80 MHz - 6 GHz 5 V/m 350 V/m MEASUREMENT UNCERTAINTY Frequency (MHz) Frequency response Axial isotropy / +4 db +/- 0.5 db / +5 db +/- 0.7 db / +7 db +/- 0.9 db ALARM & CONFIGURATION Reference threshold Visual alarm Audio alarm Low battery indicator Alarm threshold can be adjusted at MVG factory upon request 7 LEDs 2 tones (activated from 5 to 350 V/m) Orange flashing LED MEASUREMENT CONFIGURATION Measurement period 1 sec CONDITIONS FOR USE Temperature, humidity Battery -10 C to 50 C, 85% max humidity 2 x 1.5 V Size N Alkaline removable batteries Battery life > 1000 hours (> 50 days) (1) MECHANICAL CHARACTERISTICS Dimensions Weight (1) If no alarm is triggered x 48.5 x 28.7 mm (LxWxH) without connecting adapter 120 g with batteries 9
10 EME Guard + Accurate measurement with triaxial isotropic probe Customization of alarm thresholds Data storage software Robust, all weather design Main features User profile Anyone working close to emitting antennas (broadcast, base station, radars ) Installation and maintenance staff, broadcast, PMR and mobile phone operators or regulatory bodies employees Measurement capabilities Continuously records the electromagnetic field level and alerts user to potential over-exposure Frequency bands 27 MHz to 40 GHz Related recommendations FCC ICNIRP Safety Code /35/UE New EU Directive Exposure thresholds are user-definable and can be adapted to any recommendation System Configuration Software EME Guard Analysis Equipment Case Belt clip USB cable Battery charger Accessories Holster Services Calibration report Initial calibration Additional calibration Training Extended warranty 10 Included Optional
11 I EME Guard A user friendly and flexible instrument The EME Guard Analysis software defines two user profiles: STEP 3: Define the recording period. STEP 4: Start the device (ON/OFF button) and perform measurements. STEP 5: Import the measurements in the form of secure files using a USB cable and display the results. ➊ Administrator mode, gives additional rights to configure the device to requirements (threshold definition). ➋ User mode, enables download and visualization of measurements recorded in the embedded memory of the device. The Administrator can customize the device according to the thresholds defined by his own guidelines. > Only the Administrator is given right of access to device configuration and customize. STEP 1: Define the reference threshold that will trigger the visual alarm. The 4 warning lights are activated as soon as exposure level attains 25%, 50%, 75% and 100% of the chosen reference threshold. STEP 2: Define the thresholds that will trigger the audio and vibrating alarms: Over a 6 minute mean: the alarm is triggered as soon as the mean calculated over the preceding 6 minutes exceeds the predetermined threshold. This 6 minute calculation is the reference duration which conforms to the ICNIRP recommendations. Or: Instantaneous: as soon as a measurement exceeds the threshold, the alarms are triggered. High performance probe for accurate measurements The EME Guard is equipped with a triaxial probe which guarantees measurement isotropy. Each device comes with a calibration report. The performance of this sensor has been optimized to ensure maximum isotropy. The measurement files are downloaded on the PC s hard disc as binary files, thus ensuring the safety of historical data. Isotropy at 1400 MHz Isotropy at 2100 MHz Alarm front view 11
12 A robust product The device is equipped with an auto-test system which is launched when the device is switched on. This test ensures that the EME Guard is functioning normally and that battery level is sufficient. In any case, if the battery level is too low, an orange warning light alerts the user immediately. The case is metallic and ensures an IP55 Ingress Protection level, ideal for outdoor use. TECHNICAL CHARACTERISTICS Frequency range Upper detection limit Lower detection limit Damage Level (CW) : MEASUREMENT UNCERTAINTY Axial isotropy Frequency response ALARM & CONFIGURATION Reference threshold Alarm mode Visual alarm Audio alarm Vibrator Low battery indicator 27 MHz 40 GHz 200 V/m 5 V/m > 4000 V/m (> 29 db above standard) +/- 1 db at 1400 MHz +/- 2 db at 2100 MHz 27 MHz GHz : +/- 3 db 2.5 GHz - 6 GHz : + 6/0 db 6 GHz - 10 GHz : + 12/+ 6 db 10 GHz - 20 GHz : + 10/0 db 20 GHz - 40 GHz : + 8/- 3 db Configurable by the user 20, 40, 60, 80, 100 or 140 V/m Instantaneous or 6 min. mean 4 LEDs 25%, 50%, 75% and 100% of the reference threshold Activated (from 5 V/m to 137 V/m) or de-activated Activated (from 5 V/m to 137 V/m) or de-activated Orange LED CONDITIONS FOR USE Temperature, humidity Power supply of battery charger Battery Battery life Type of link MECHANICAL CHARACTERISTICS -10 to 50 C, 85% max. humidity VAC, Hz Lithium-Ion > 100 hours USB Dimensions 172 x 60 x 35 mm (H, L, W) without belt clip Weight 320 g Protection IP 55 HARDWARE REQUIREMENTS Processor Cable link Operating system Memory Free space on hard disk PC Pentium 500 MHz or equivalent USB XP / WIN7 / WIN8 256 MB RAM 100 MB MEASUREMENT CONFIGURATION Update period for display and alarms Measurement recording Recording capacity Recording period 1 sec Activated or de-activated measurements MAX sec Duration of recording min. 1 mn max. Duration in mn = points X recording period (sec) 60 12
13 FlashRad + Alert users with sound and light Cover frequencies of all cellular networks including short pulsed signals NEW Monitor low EMF levels in public areas Main features User profile Companies situated near antennas or radar transmitters, who wish to protect their employees from questionable EMF levels (military bases, airports, etc.) Measurement capabilities Continuous measurement of EMF levels. Each monitor detects signals and then transmits the data to the surveillance PC to be processed individually Data is collected separately from each monitor in place Frequency bands 900 MHz 11 GHz; higher or lower frequencies possible Safety recommendations EMF exposure limits can be defined by users and adjusted to any regulation or recommendation Product Configuration Software FlashRad software on CD Rom Equipment External connectors (mounted on cable or not) Ground or wall support Accessories Case LEDs box with alarm + USB cable Services Initial calibration Calibration report Ground or wall installation Training Additional calibration Extended warranty Included Optional 13
14 FlashRad is a safety wideband exposure monitoring system that performs continuous measurements of electromagnetic field (EMF) levels. It detects all kinds of pulsed signals, including short pulsed radar, emitted from various sources outside a building. When predetermined EMF levels are exceeded, the FlashRads monitor sounds and flashes a warning in its immediate surroundings while sending a signal to the surveillance PC for action. Overview of FlashRad systems network Antenna Ethernet network LEDs Box (alarms) optional Surveillance PC USB Link FlashRads are connected to a PC via Ethernet. Continuous EMF level measurements are sent to the PC where the FlashRad monitoring system software collects and displays the incoming data. If the FlashRads detect excessive RF levels, a signal is sent to the PC indicating which monitor is detecting the overexposed area. The technician can then take action. Note that each monitor can be stopped or started as necessary. The PC will send a signal to trigger the alarms in the FlashRads when the EMF levels exceed the predetermined levels. A LED light box is available as an option to allow monitoring in multiple areas. It is connected to the PC by a USB cable of up to 10 meters. 14
15 I FlashRad TECHNICAL CHARACTERISTICS HIGH LEVEL PULSED WORKERS AREA PUBLIC AREA SIGNALS (RADAR...) (BTS, TEST...) Probe reference FR100 FR200 FR300 Probe Isotropic 3-axes probe Isotropic 3-axes probe Isotropic 3-axes probe Frequency range 900 MHz 11 GHz 700 MHz 6 GHz 700 MHz 3 GHz Lower detection limit 50 V/m 10 V/m 0.5 V/m Upper detection limit 1000 V/m 200 V/m TBD Destruction limit > 1500 V/m > 300 V/m TBD Minimum pulse 1 µs 50 µs TBD width measurement Mechanical installation MEASUREMENT UNCERTAINTY Axial isotropy 900 MHz 6 GHz 700 MHz 6 GHz TBD (@150 V/m) : +/-1 db (@50 V/m) : +/-1 db 6 GHz 11 GHz (@150 V/m) : +/-2.2 db Frequency response 900 MHz 1 GHz 700 MHz 2 GHz TBD (@150 V/m) : +3.8/-1.2 db (@50 V/m) : +/-3 db 1 GHz 8 GHz (@150 V/m) : 2 GHz 6 GHz (@50 V/m) : +/-2 db +3/+1 db 8 GHz 11 GHz (@150 V/m) : +5/+3 db Linearity +/-0.5 db +/-1 db TBD ( V/m) ( V/m) Ground Installation ALARM & CONFIGURATION Alarms Reference threshold Measurement records Measurement interval Audio & visual Configurable from lower until upper detection limits of the probe On PC 1-60 sec CONDITIONS FOR USE Temperature, humidity Power supply Type of network connection -15 C - 50 C, 95% max humidity VAC, Hz Ethernet Wall installation SOFTWARE REQUIREMENTS Processor PC Pentium 500 MHz or equivalent Network connection Ethernet Operating system Windows XP 7/8 Memory 256 MB RAM Free space on hard disk 100 MB MECHANICAL CHARACTERISTICS Dimensions Weight Height = 570 mm Diameter = 100 mm 3.6 kg Protection IP 55 FlashRad 15
16 16
17 Public Safety
18 EME Spy LTE 800 MHz / 2600 MHz frequency bands included Independent measurement on Uplink and Downlink for cellular network bands Real time monitoring on PC (USB) or Smartphone (Bluetooth) Android Application now available Watch a success story of EME Spy 140 Main features User profile Municipalities, governmental agencies, regulatory bodies, research laboratories, universities, broadcast, PMR, and mobile phone operators Measurement capabilities Continuous monitoring of personal exposure to electromagnetic fields and identification of the contributors Frequency bands 20 selected frequency bands from 88 MHz 5850 MHz Safety recommendations Measurements can be compared with the reference levels advised by ICNIRP Real time visualization kit (optional) The field level for each frequency band is displayed as it is measured Exports data to the EME Spy Analysis software for post processing and backup Product Configuration Equipment EME Spy analysis software User manual USB cable 4 rechargeable batteries Battery charger Case Real time visualisation kit Services Initial calibration Calibration report Installation Training Additional calibration Extended warranty 18 Included Optional
19 I EME Spy 200 TECHNICAL CHARACTERISTICS FREQUENCY Frequency Frequency RANGES MIN (MHz) MAX (MHz) FM TV TETRA I TETRA II TETRA III TV4& LTE 800 (DL) LTE 800 (UL) GSM + UMTS 900 (UL) GSM + UMTS 900 (DL) GSM 1800 (UL) GSM 1800 (DL) DECT UMTS 2100 (UL) UMTS 2100 (DL) WiFi 2G LTE 2600 (UL) LTE 2600 (DL) WiMax WiFi 5G PROBE CHARACTERISTICS Probe Sensitivity Dynamic MEASUREMENT CONFIGURATION Number of data points Logging intervals Tri-axial E-field probe 80 MHz 6 GHz FM, TV3, TETRA, TV4 & 5, WiFi 5G = 0,01 V/m LTE 800, GSM, DCS, DECT, UMTS, WiFi 2G, LTE 2600, WiMax = 0,005 V/m 61.6 db (up to 6 V/m) (1) Uplink: Sending of information from the mobile station to the BTS (2) Downlink: Sending of information from the BTS to the mobile station max From 1 to 4 bands: s From 5 to 10 bands: s From 11 to 20 bands: s 3,0 2,5 2,0 1,5 Differentiating uplink (1) 1,0 and downlink (2) is 0,5 not only useful to assess the contribution 0,0 of each transmitter, but also to avoid discrepancy in the results by phones emitting close to the dosimeter. EME Spy Analysis main window OPERATING CONDITIONS 3,0 2,5 2,0 1,5 1,0 0,5 0,0 3,0 2,5 2,0 1,5 1,0 0,5 0,0 Temperature, humidity Battery life* -10 to 50 C, 85% of humidity Recording mode: > 15 hours with a recording period of 10 sec > 6 hours with a recording period of 4 sec BlueTooth mode: > 10 hours of recording * 2 rechargeable batteries Vertical Polarization 3,0 2,5 2,0 1,5 1,0 0,5 0,0 Horizontal Polarization MECHANICAL CHARACTERISTICS Dimensions x 79 x 49.7 mm (H x L x W) Weight 440 g Protection IP 55 HARDWARE REQUIREMENTS Processor PC Pentium 500 MHz Cable link USB Port Operating system XP / WIN7 / WIN8 Free space on hard disc 200 MB 19
20 EME Spy 200 Real Time Kit A streamlined and ergonomic screen allows the visualization of only the most useful information in real time on a small laptop PC, tablet or smartphone via a ferrite USB cable (for Windows) or BlueTooth (for Android) ON WINDOWS PC OR TABLET ON ANDROID SMARTPHONE OR TABLET Real-time visualization of results via USB. Real-time visualization of results via BlueTooth. EME Spy Android Application NEW Viewing real-time measurements of electromagnetic field of the EME Spy. View this at Google Earth*! Measurements of EME Spy are transmitted by a Bluetooth link to an Android smartphone to display the exposure levels generated by the main radio services (FM, TV, Cellular Networks, Wifi...). BASIC MODE PRO MODE Real-time display X X Backup + post-processing of measurements for compatibility with the EME Spy Analysis software Geo-location of the measurements with GPS position Generation of *.kmz files for compatibility with Google Earth The EME Spy Android APP is certified for Smartphones below: - Galaxy S series (Samsung) - Xperia Neo (Sony Ericsson) - Slim Cink (Wiko) - XT925 (Motorola) X X X Geolocalized measurements in Paris * Google Earth installation required. Visit our website for more information. Real-time Visualization Google Map View 20
21 INSITE Free + Compatible with most spectrum analyzers available on the market Tri-axial probes with excellent isotropic measurement Compatible with WIN7/WIN8 Additional option for ANFR V3 protocols Main features Measurement capabilities Performs in situ spot measurements User profile Regulation agencies, certification offices, municipalities, broadcast, PMR and mobile phone operators, installers, research laboratories, administrative bodies and more Frequency bands 100 KHz to 6 GHz Related recommendations ECC/REC/(02)04, EN50383 and EN Compatible with most spectrum analyzers ANRITSU: MT8212B, MT8220A, MT8222A, MS2711A/D, MS2661B, MS2721B, MS2665C, MS2724B, MS2713E, S332D, S362E WILLTEK: 9101/9102 Rohde & Schwarz: FSH3/6, FSH4/8, ZVL3, FSHP, FSV3, FSL6 AGILENT: E7495B, ESA series, 856xEC series, N9912A BIRD: Signal Hawk System Configuration Software INSITE Free on CD Rom with dongle key INSITE Free/ANFR on CD Rom with dongle key Equipment 100 KHz to 3 GHz probe 700 MHz to 6 GHz probe Spectrum analyzer Switch box (with battery charger) Probe holder Wooden tripod Accessories Cables Services Initial probe and cable calibration Additional calibration Training Extended warranty Included Optional Required 21
22 INSITE Free is composed of a probe connected to a switch/amplification box. The system also requires a spectrum analyzer. These elements can be operated either manually or remotely through INSITE Free software. The software enables the user to define measurement scenarios, analyze measurements, review the results graphically and automatically generate reports in Excel format. The switch enables successive selections of the three measurement axes to obtain an isotropic result without changing the position of the probe. Equipped with an amplifier, the switch also improves the sensitivity of the system over the 100 KHz to 30 MHz frequency bands. RF link Spectrum analyzer Switch Probe Computer Description of the measurement chain with a 6 GHz measurement probe Measurement scenarios can be defined by the user to fit specific requirements ➊ INSITE Free SW is a flexible tool that can be configured by the user to perform measurements and generate reports according to specific measurement protocols, in particular those recommended by ECC. ➋ In addition, for the French market, INSITE Free/ ANFR SW follows the protocol v3 of the French National Agency of Frequencies (ANFR) step by step. STEP 1: Choose hardware configuration In this first phase, the user programs the measurement session according to his own hardware configuration: spectrum analyzer, GPS, probe, cable, UMTS scanner and switch. For this purpose, the probes, cable and switch calibration files are selected and loaded. A selection of several probes is possible. INSITE Free works with all of the most frequently used spectrum analyzers. STEP 2: Define measurement scenario Once the hardware has been configured, the user can program the measurement scenarios: Choose frequency bands to be measured from a list or create user-defined bands Define the channels or specific carriers Define channel width Choose attenuation mode Choose analysis mode (peaks, TDMA or W-CDMA) Choose automatic or manual definition of RBW/VBW 22
23 I INSITE Free STEP 4: Visualize results The results can be visualized with the following functions: Full scan or per frequency band Zoom in with peak identification threshold 3 types of scales for a better high and low band visualization Quick view of element s properties Selection of BCCH for TDMA Analysis STEP 3: Perform measurement analysis. The data collected for each band is presented on the main window of the software. Measurements corresponding to each of the three axes can be displayed in order to check the polarisation of the electric field. Depending on the characteristics of the spectrum analyzer, the user can repeat the following analysis modes: CW Analysis: selection of peaks according to predefined threshold TDMA analysis: extrapolation of BCCH value W-CDMA analysis: UMTS decoding (measurement and extrapolation of the CPICH value) The user can re-launch measurements using specific detection modes (positive peak, negative peak, sample ) and measurement modes (Max. hold, Min. hold, and average) available with the spectrum analyzer. Sessions are saved in XML and results can be exported to Excel. The results can be compared to the reference levels given by specific guidelines. Two guidelines are available by default: ICNIRP Safety Code 6 (Other reference levels can be added upon request). High performance isotropic probes to cover the 100 KHz to 6 GHz frequency ranges Two probes are available: from 100 KHz to 3 GHz and from 700 MHz to 6 GHz. Both probes are made of three orthogonal monopoles. The patented shape of each monopole optimizes the functioning and isotropy of the probe over the entire frequency range. MECHANICAL CHARACTERISTICS / 100 KHz - 3 GHz PROBE Dimension (without cable) Weight RF cable length Connector 406 mm 980 gr 2 m 3N Protection IP 44 Conditions for use (temperature, humidity) -10 to 50 c, 85 % humidity ELECTRICAL CHARACTERISTICS / 100 KHz - 3 GHz PROBE TDMA Analysis CW Analysis W-CDMA Analysis Sensitivity at 900 MHz (Given for a spectrum analyzer sensitivity of -90 dbm) (Cable loss taken into account) Max. E-field/900 MHz Isotropy at 900 MHz Isotropy at 1800 MHz 1 mv/m 200 V/m ± 1 db ± 1,7 db 23
24 100 KHz - 3 GHz probe antenna factor Axial Isotropy at 900 MHz 100 KHz - 3 GHz probe sensitivity without amplifier 100 KHz - 30 MHz probe sensitivity with amplifier 100 KHz - 3 GHz Axial Isotropy with horizontal polarization 100 KHz - 3 GHz Axial Isotropy with vertical polarization 24
25 I INSITE Free E (mv/m) MECHANICAL CHARACTERISTICS / 700 MHz - 6 GHz PROBE Dimension (without 8 cable) 70 mm Weight RF cable length Connector gr 2 m 3N Protection 2 IP 44 Conditions for use (temperature, humidity) 10 to 50 c, 85 % humidity Frequency (MHz) ELECTRICAL CHARACTERISTICS / 700 MHz - 6 GHz PROBE Sensitivity at 900 MHz (Given for a spectrum analyzer sensitivity of -90 dbm) (Cable loss taken into account) Max. E-field/900 MHz Isotropy at 900 MHz Isotropy at 1800 MHz 3,5 mv/m 200 V/m +/- 1,6 db +/- 2,5 db 700 MHz - 6 GHz probe antenna factor Axial Isotropy 3.6 GHz AF (db) Frequency (MHz) 90 deg deg deg deg deg 0 deg 270 deg F1 F2 F3 700 MHz - 6 GHz probe sensitivity E (mv/m) Axial Isotropy 5.6 GHz deg deg deg deg deg 0 deg 270 deg Frequency (MHz) PV PH V/m 270 deg PV PH V/m AF (db) Frequency (MHz) 25 F1 F2 F3
26 Perform isotropic measurements without changing the position of the probe INSITE Free System performs a measurement for each axis and all predefined bands. The power value measured on each axis is then converted into field value. FOR EACH BAND One scan for each axis X Y Z Conversion in field value [E] (db V/m) = Pmes (dbm) 13 + loss + AF (db m-1) AF: Antenna Factor loss: cable loss, switch loss Isotropic value calculation [E TOT ] (V/m) = ( [Ex] 2 (V/m) + [Ey] 2 (V/m) + [Ez] 2 (V/m) ) 1/2 SWITCH BOX CHARACTERISTICS Dimensions 100 mm x 200 mm x 50 mm Frequency range 100 KHz 6 GHz Battery life 4 hours Immunity 200 V/m Protection IP55 Frequency range amplifier 100 KHz 30 MHz N connections Output : 1 female Max power input for amplifier -30 dbm Input : 3 female Interface USB Amplifier gain 32 db Working conditions -10 to 50 C, 85% humidity Intermodulation dbm dbm Sketch of the switch Transmission loss 26
27 I INSITE Free Antenna factor with or without amplifier Amplifier gain HARDWARE REQUIREMENTS Computer Processor 2 GHz Cable link* 3 USB Ports Operating system XP / WIN7 / WIN8 Memory 2 GB RAM Free space 500 MB free space on hard disc * Serial port, USB, Ethernet or GPIB may be necessary depending on the analyzer 27
28 CONTACT US: About Microwave Vision Group (MVG) Since its creation in 1986, The Microwave Vision Group (MVG) has developed a unique expertise in the visualization of electromagnetic waves. These waves are at the heart of our daily lives: Smartphones, computers, tablets, cars, trains, planes - all these devices and vehicles would not work without them. Year after year, the Group develops and markets systems that allow for the visualization of these waves, while evaluating the characteristics of antennas, and helping speed up the development of products using microwave frequencies. The Group's mission is to extend this unique technology to all sectors where it will bring strong added value. Since 2012, MVG is structured around 4 departments: AMS (Antenna Measurement Systems), EMC (Electro-Magnetic Compatibility), EIC (Environmental & Industrial Control), and NSH (National Security & Healthcare). MVG is present in 12 countries, and generates 90% of sales from exports. The Group has over 350 employees and a loyal customer base of international companies. MVG s customer satisfaction program The RF Safety/EMF products are designed and produced by MVG s dedicated center based in Brest. The local team is supported by a network of regional offices in North America, Asia and Europe. Our presence close to our customers is essential to ensure high quality sales services. MVG is ISO 9001:V2008 certified. MANCHESTER Production site Office Contact your local sales representative for more information [email protected] NEW DELHI HYDERABAD Support center North America ORBIT/FR Corporate Headquarters 506 Prudential Road Horsham, PA 19044, USA Tel: Fax: MVG Inc Barrett Park Dr., Suite 104 Kennesaw, GA 30144, USA Tel: Fax: AEMI 1320 Air Wing Road, San Diego (Otay Mesa), CA92154, USA Tel: Fax: EMEA MVG (SATIMO) Industries Headquarters 17, avenue de Norvège Villebon Sur Yvette, FRANCE Tel: +33 (0) Fax : +33 (0) MVG (SATIMO) Industries Bretagne Technopole Brest Iroise Z.I. du Vernis 225 rue Pierre Rivoalon Brest, FRANCE Tel: +33 (0) Fax: +33 (0) MICROWAVE VISION Italy Via Castelli Romani, Pomezia (Rome), ITALY Tel: Fax: ORBIT/FR Germany Johann-Sebastian-Bach-Str. 11 Vaterstetten 85591, GERMANY Tel: +49 (0) Fax: +49 (0) MICROWAVE VISION Sweden PO Box Alingsas Gothenburg, SWEDEN Tel: Fax: ORBIT/FR Israel 1 Gesher Ha-Ets St., P.O. Box 12096, Emek Hefer Industrial Park, ISRAEL Tel: Fax: MICROWAVE VISION Corporate Headquarters 47, Boulevard St Michel Paris, FRANCE Tel: +33 (0) Fax: +33 (0) Asia MICROWAVE VISION LIMITED Hong Kong Suite 702, 7 th floor Cyberport Cyberport Road Pok Fu Lam, HONG KONG Tel: Fax: MICROWAVE VISION Japan #101 Confort Murashi-Nakahara, , Shimokodanaka, Nakahara-ku, Kawasaki-city KANAGAWA, JAPAN Tel: Fax: MVG Graphic design: pictures: Istock morfous, hansenn, bunhill - Fotolia Richtfunk - All rights reserved.
Continuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057-03/G Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total EMF values Electric field monitoring
IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz
International Electrotechnical Commission IEC TC106 Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz R. C. Petersen Chairman Secretariat and
RF safety at base station sites
RF safety at base station sites CONTENTS 1 Purpose and scope................................................. 2 2 Introduction........................................................ 2 3 Basic information...................................................
Nardalert S3 Non-Ionizing Radiation Monitor
Patent Pending Non-Ionizing Radiation Monitor Field Replaceable Sensor Modules Color LCD Display Multi-Color Alarm LED s USB Interface for Data and Charging Interchangeable Lanyard or Belt Clips Comprehensive
Frequency selective monitoring and logging of environmental electromagnetic fields
FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser
Continuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057 Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total emf values Magnetic fields monitoring from
Annex to the joint statement: Exposure of the general public to radiofrequency fields
16 November 2009 Annex to the joint statement: Exposure of the general public to radiofrequency fields 1. Introduction This document presents typical exposure of the general public to radiofrequency (RF)
The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz
The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz J. Klima, R. Ščehovič Department of Physics, Faculty of Natural Sciences, University of Mathias Bel, Tajovského
How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)
1 2 The range of RF spans 3 KHz (3000 Hz) to 300 GHz (300 million Hz) Frequencies of RF devices range from the low frequency AM broadcasts (80 MHz) to higher frequency mobile phones (1900 MHz) smart meters
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and coniguration requirements
RF EXPOSURE LIMITS AND TESTING REQUIREMENTS
RF EXPOSURE LIMITS AND TESTING REQUIREMENTS Jay Moulton Vice President March 12, 2013 1 OVERVIEW Specific Absorption Rate (SAR) and Maximum Permissible Exposure (MPE) Standards and Limits Evaluation Methods
CONTENTS --------------------------------------------------------------------------------------
en WiFi USB DONGLE CONTENTS -------------------------------------------------------------------------------------- 9 SAFETY AND SET-UP 10 WiFi USB DONGLE 10 Packing contents 10 Special features 10 Connection
Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules
Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers
Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform
Application Note Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform By: Richard Komar Introduction With the rapid development of wireless technologies, it has become
Human Exposure Limits
Human Exposure Limits Session 3 0 Version December 2014 Learning objectives In this session we will: Learn about the international exposure limits for workers and the public Learn about methods for assessing
Selected Radio Frequency Exposure Limits
ENVIRONMENT, SAFETY & HEALTH DIVISION Chapter 50: Non-ionizing Radiation Selected Radio Frequency Exposure Limits Product ID: 94 Revision ID: 1736 Date published: 30 June 2015 Date effective: 30 June 2015
EMR-300 Broadband RF Survey Meter
Electric d Magnetic Field Measurement EMR-300 Broadbd RF Survey Meter Available with Isotropic Probes to cover 3 khz to 60 GHz Easy-to-Use Design Lightweight d Rugged Cost Effective Fully Automatic Zeroing
Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual
Field Analyzer FA106 and FA306 Users Manual 1 Contents Contents...2 Preface...3 Chapter 1 Basic Functions...4 1.1 Turning on/off...4 1.2 Choosing the required measuring mode...4 1.3 Picture of front panel...5
Measuring electric and magnetic fields
NARDA BROADBAND FIELD METER NBM-520 Measuring electric and magnetic fields ranging from high frequency to microwaves Non-directional measurement using isotropic probes for applications in the frequency
Wireless Broadband: Health & Safety Information
Wireless Broadband: Health & Safety Information Introduction The increasing use of mobile phones and other wireless technology has been accompanied by public debate about possible adverse effects on health.
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
R&S TS-EMF EMF Measurement System Easy, frequency- selective measurement of EMF emissions
Test & Measurement Data Sheet 03.00 R&S TS-EMF EMF Measurement System Easy, frequency- selective measurement of EMF emissions R&S TS-EMF EMF Measurement System At a glance In combination with Rohde & Schwarz
Raptor RXi Ultra-fast scanning Countersurveillance Receiver
data sheet RAPTOR RXi DATA SHEET A MATTER A MATTER OF OF NATIONAL SECURITY Raptor RXi Ultra-fast scanning Countersurveillance Receiver Features + Scans 26GHz in less than 4 seconds at 3kHz resolution (approx.
WIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
PHOENIX CONTACT - 03/2007
PSI-WL-PLUG-USB/ Bluetooth USB Adapter INTERFACE Data Sheet 103170_00_en PHOENIX CONTACT - 03/2007 Description The Bluetooth USB adapter provides an easy wireless connection between devices with a USB
LTE: Technology and Health. 4G and Mobile Broadband
LTE: Technology and Health 4G and Mobile Broadband LTE Technology and Health Mobile Broadband typically refers to providing customers with high speed data while on the move. There are several technologies
Mobile Phone Base-Station Audit
Mobile Phone Base-Station Audit Audit site: Aylesbury Road Wing Leighton Buzzard Beds LU7 0NY The Office of Communications (Ofcom) is responsible for management of the civil radio spectrum in the UK. Following
Non-ionizing electromagnetic radiation monitoring in Greece
Non-ionizing electromagnetic radiation monitoring in Greece Antonis Gotsis, Nikolaos Papanikolaou, Dimitris Komnakos, Agamenon Yalofas, and Dr Philip Constantinou Mobile Radio-Communications Laboratory,
Noise Monitoring Software, version 7.0 Types 7802 and 7840
PRODUCT DATA Noise Monitoring Software, version 7.0 Types 7802 and 7840 The basic software packages Noise Monitoring Software Types 7802 and 7840 are the central point in any Brüel & Kjær noise monitoring
Product Information S N O. Portable VIP protection CCTV & Alarm System 2
Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to
iva Cable & Antenna Analyzer
iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return
Wireless Broadband Access
Wireless Broadband Access (Brought to you by RMRoberts.com) Mobile wireless broadband is a term used to describe wireless connections based on mobile phone technology. Broadband is an electronics term
Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets
Ministry of Environmental Protection Ministry of Communications Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets Based on author s PhD thesis/book- An analysis of regulatory
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors GSM Timeslot Burst Power Measurement Product Note Table of Content Introduction 2 Measuring GSM Timeslot 4 Signal Overview of Agilent U2000 5 Series USB Power Sensors
Agilent E6832A W-CDMA Calibration Application
Agilent E6832A W-CDMA Calibration Application For the E6601A Wireless Communications Test Set Data Sheet The next generation of mobile phone manufacturing test. E6601A is the newest test set from Agilent
Automated Meter Reading Frequently Asked Questions. What is AMR?
Automated Meter Reading Frequently Asked Questions What is AMR? AMR stands for Automated Meter Reading. It is a method of using advanced communications technology to read meters remotely. It reduces human
SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012
1 (34) Report issued by an Accredited Laboratory Rapport utfärdad av ett ackrediterat laboratorium This laboratory is accredited to SS-EN ISO/IEC 17025 (SWEDAC accreditation no. 1761). SAR Test Report:
Bluetooth: Global Certification Requirements
Bluetooth: Global Certification Requirements Paul G. Didcott Understanding certification requirements can speed time to market for Bluetooth products. Bluetooth is a low-power wireless technology deployed
Measurements of radiofrequency fields from a WEL Networks Smart Meter
Measurements of radiofrequency fields from a WEL Networks Smart Meter Report 2012/36 This report was prepared for: WEL Networks Ltd P O Box 925 Hamilton Report prepared by: Martin Gledhill Finalised: 7
Antenna Trainer EAN. www.edibon.com. Technical Teaching Equipment INTRODUCTION
Antenna Trainer EAN Technical Teaching Equipment Products Products range Units 3.-Communications INTRODUCTION Antennas are the main element of aerial communications. They are the transition between a transmission
FB-500A User s Manual
Megapixel Day & Night Fixed Box Network Camera FB-500A User s Manual Quality Service Group Product name: Network Camera (FB-500A Series) Release Date: 2011/7 Manual Revision: V1.0 Web site: Email: www.brickcom.com
Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.
Targus Wireless Remote Presenter Making Your Mobile Life Easier. Visit our Web site at: www.targus.com Features and specifications are subject to change without notice. 2003 Targus Corp. 400-0110-001B
M2M Connectivity T: 08456 200 200 W: www.2circles.com
Product Profile M2M Connectivity Number of devices in billions 2 Circles M2M at a glance Partnered with Telefónica, one of the largest mobile network operators in the world, we can offer M2M connectivity
Agilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP
Department of Electrical and Computer Engineering Ben-Gurion University of the Negev LAB 1 - Introduction to USRP - 1-1 Introduction In this lab you will use software reconfigurable RF hardware from National
R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface
R&S UMS12 Monitoring System Modular monitoring system with open programming interface Radiomonitoring & Radiolocation Data Sheet 01.00 R&S UMS12 Monitoring System At a glance The R&S UMS12 is a new member
External Hard Drive esata & USB 2.0 Combo. User Guide English
External Hard Drive esata & USB 2.0 Combo User Guide English Contents Introduction 3 Controls, Connectors and Indicators 3 Front Panel Area 3 Rear Panel Area 3 About the Hard Drive 4 Locating the Drive
AN1200.04. Application Note: FCC Regulations for ISM Band Devices: 902-928 MHz. FCC Regulations for ISM Band Devices: 902-928 MHz
AN1200.04 Application Note: FCC Regulations for ISM Band Devices: Copyright Semtech 2006 1 of 15 www.semtech.com 1 Table of Contents 1 Table of Contents...2 1.1 Index of Figures...2 1.2 Index of Tables...2
TekSmartLab TBX3000A, TSL3000B Datasheet
TekSmartLab TBX3000A, TSL3000B Datasheet TekSmartLab is the industry's first network-based instrument management solution for teaching labs that brings a more efficient lab experience. With the TekSmartLab,
802.11ac Power Measurement and Timing Analysis
802.11ac Power Measurement and Timing Analysis Using the 8990B Peak Power Analyzer Application Note Introduction There are a number of challenges to anticipate when testing WLAN 802.11ac [1] power amplifier
AirMax2. 802.11g High Powered Outdoor CPE. PoE. Simple All-In-One Solution. Long Distance Radio. Clear. 10dBi
AirMax2 802.11g High Powered Outdoor CPE Wireless-G Outdoor CPE Built-in 10dBi Weather-Proof Housing ClearSignal Anti-Interference Technology Client, AP, Bridge, AP Router, WISP Router, WDS, and Universal
Disclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
AirTight C-55 Access Point
AirTight C-55 Access Point Dual radio, dual concurrent 2x2:2 Wi-Fi access or 24/7 wireless intrusion prevention. Designed for High Performance The AirTight C-55 is an enterprise grade dual radio, dual
Microwave Exposure from Mobile Phones and Base Stations in Sweden
Microwave Exposure from Mobile Phones and Base Stations in Sweden Prof. Dr. Yngve Hamnerius and Thomas Uddmar Chalmers University of Technology, Department of Electromagnetics, SE 41 96 Goteborg, Sweden,
Wireless Day / Night Cloud Camera TV-IP751WIC (v1.0r)
(v1.0r) TRENDnet s Wireless Day / Night Cloud Camera, model, takes the work out of viewing video over the internet. Previously to view video remotely, users needed to perform many complicated and time
Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)
Issue 3 June 2009 Spectrum Management and Telecommunications Radio Standards Specification Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Aussi disponible
Body SAR and EU. B. Derat
Body SAR and EU B. Derat Overview / Outline New Approach: Directive / Standards Current applicable standard IEC/EN 62209-2:2010 Tablet case study Future of EU body SAR testing Maintenance of IEC 62209-2
How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab
How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab For questions and details contact Dennis at [email protected] Introduction The CE mark (an acronym for the French
Measurement, analysis, and monitoring of RF signals
NRA-2500, NRA-3000 and NRA-6000 Narda Remote Spectrum Analyzer Measurement, analysis, and monitoring of RF signals 19" rack mountable Spectrum Analyzer for remote controlled measurements and analysis of
ACRS 2.0 User Manual 1
ACRS 2.0 User Manual 1 FCC Regulatory Information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
Radio waves and health. Mobile communications
Radio waves and health Mobile communications Mobile communications and health Mobile telephony Radio communications have been used for more than a hundred years in various sorts of applications. Already
R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz
Test & Measurement Data Sheet 02.00 R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz R&S R-Line Compact Test Chamber At a glance The R-Line
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
Analysis of Immunity by RF Wireless Communication Signals
64 PIERS Proceedings, Guangzhou, China, August 25 28, 2014 Analysis of Immunity by RF Wireless Communication Signals Hongsik Keum 1, Jungyu Yang 2, and Heung-Gyoon Ryu 3 1 EletroMagneticwave Technology
CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer
CellAdvisor JD725A Dual-Port Cable and Antenna Analyzer Many modern wireless base stations are a complex system of multiple RF components, such as low-noise amplifiers (LNA), duplexers, and tower-mounted
Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015
Report Of Shielding Effectiveness Test For SafeSleeve Radiation Shielding Technology Test Date(s): June 07 June 09, 2015 Issue Date: June 10, 2015 UST Project No: 15-0137 Total Number of Pages Contained
iva Cable & Antenna Analyzer
iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return
Jabra LINK 220 Jabra LINK 220a
Jabra LINK 220 Jabra LINK 220a USER MANUAL www.jabra.com 1 2009 GN Netcom A/S. All Rights Reserved. This user guide is published by GN Netcom A/S. The information in this user guide is furnished for informational
1.5 GHz Active Probe TAP1500 Datasheet
1.5 GHz Active Probe TAP1500 Datasheet Easy to use Connects directly to oscilloscopes with the TekVPI probe interface Provides automatic units scaling and readout on the oscilloscope display Easy access
Avaya WLAN 9100 External Antennas for use with the WAO-9122 Access Point
Avaya WLAN 9100 External Antennas for use with the WAO-9122 Access Point Overview To optimize the overall performance of a WLAN in an outdoor deployment it is important to understand how to maximize coverage
Impedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
PRO 5000 CPE 1D Quick Installation Guide
PRO 5000 CPE 1D Quick Installation Guide Introduction This Quick Installation Guide covers the basic installation of the PRO 5000 CPE. For more information, refer to the relevant sections in the Product
Selective measurement of high frequency electromagnetic
Selective Radiation Meter SRM-3006 Selective measurement of high frequency electromagnetic fields Complete, easy to use test system, consisting of a base unit and measuring antennas, for non-directional
Agilent 8762/3/4A,B,C Coaxial Switches
Agilent 8762/3/4A,B,C Coaxial Switches Technical Overview High performance switches for microwave and RF instrumentation and systems Agilent Technologies offers a ver satile line of multiport coaxial switches.
PSM 900 and PSM 1000 Personal Monitor Systems TWO SYSTEMS. INFINITE POSSIBILITIES.
PSM 900 and PSM 1000 Personal Monitor Systems TWO SYSTEMS. INFINITE POSSIBILITIES. PSM 900 AND PSM 1000 PERSONAL MONITOR SYSTEMS. ONLY FROM SHURE. PSM 900 PSM 1000 PSM 900 and PSM 1000 Personal Monitor
R&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
Keysight N6854A Geolocation System. Configuration Guide
Keysight N6854A Geolocation System Configuration Guide 02 Keysight N6854A Geolocation System - Configuration Guide This guide will help you configure a geolocation system that meets your needs and includes
Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator
Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator Application Note 1 Summary Introduction As a part of the certification
R&S ZNBT8 Vector Network Analyzer Specifications
ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4
The Salzburg Model: A Precautionary Strategy for Siting of Base Stations
The Salzburg Model: A Precautionary Strategy for Siting of Base Stations Dr. Gerd Oberfeld, Dr. Christoph König Federal State of Salzburg, Public Health Department, Environmental Health P.O. Box 527, A-5010
Next Generation Test Chambers. Bluetest AB
Next Generation Test Chambers Bluetest Background Founded in 2001 by Professor Kildal at Chalmers University, Gothenburg, Sweden The vision was to perform tests: - Fast - Easy - Cost effectively 2006:
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER System for flow measurement, data acquisition and transmission for wastewater with long battery life With Long Life Battery Open Channel Flow Meter
Aspects of remote monitoring and recording system of non-ionizing electromagnetic radiation
Aspects of remote monitoring and recording system of non-ionizing electromagnetic radiation D. S. Šuka*, M. I. Simić**, P. V. Pejović** *Faculty of Electrical Engineering, University of East Sarajevo,
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
MEASUREMENT AND ANALYSIS OF RF EME LEVELS FROM MOBILE TELEPHONE BASE STATIONS LOCATED AT LEICHHARDT, NSW
AUSTRALIAN RADIATION PROTECTION AND NUCLEAR SAFETY AGENCY A R P N S A Lower Plenty Road YALLAMBIE VIC 3085 Phone 61 3 9433 2211 Fax 61 3 9432 1835 E-mail: [email protected] Web: www.arpansa.gov.au
Wireless PTZ Cloud Camera TV-IP851WC (v1.0r)
(v1.0r) TRENDnet s Wireless PTZ Cloud Camera, model, takes the work out of viewing video over the internet. Previously to view video remotely, users needed to perform many complicated and time consuming
EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5
EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA
This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples.
Antenna Basics This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples. What Do Antennas Do? Antennas transmit radio
GPS/GSM monitoring and security of vehicles Remote control and protection of premises and buildings Rail transport solutions Personal tracking
GPS/GSM monitoring and security of vehicles Remote control and protection of premises and buildings Rail transport solutions Personal tracking solutions COMPANY HISTORY ACHIEVEMENTS CERTIFICATES Company
Understanding Range for RF Devices
Understanding Range for RF Devices October 2012 White Paper Understanding how environmental factors can affect range is one of the key aspects to deploying a radio frequency (RF) solution. This paper will
QuickSpecs. HP ipaq 300 Series Travel Companion. Overview. 1. Power button 1. High-capacity SD slot 2. Bluetooth indicator. 1. Speaker 1.
Overview Front Left side 1. Power button 1. High-capacity SD slot 2. Bluetooth indicator Back 1. Speaker 1. Scroll wheel 2. Right Side Connectors (covered): GPS antenna, headphone, mini- USB 3. Reset DA
Electromagnetic Field Safety
SAR A Basic Restriction for Electromagnetic Field Safety David Baron, PE Consulting Engineer Electromagnetic Field Safety [email protected] NOTE. CENAM is not responsible for the content of this document.
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
QuickSpecs. HP Wireless Keyboard and Mouse. Models
Overview 1. Wireless Keyboard 2. USB Wireless Transceiver 3. Wireless Mouse Models QY449AA Introduction The combine a cordless keyboard, cordless laser mouse, and USB wireless receiver in a single package.
ARIB TR-T12-34.925 V3.0.0. Specific Absorption Rate (SAR) requirements and regulations in different regions
ARIB TR-T12-34.925 V3.0.0 Specific Absorption Rate (SAR) requirements and regulations in different regions Refer to "Notice" in the preface of ARIB TR-T12 for Copyrights. Technical Report 3rd Generation
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet