TABLE OF CONTENTS. Table of Contents

Size: px
Start display at page:

Download "TABLE OF CONTENTS. Table of Contents"

Transcription

1

2 TABLE OF CONTENTS Table of Contents 1. Specifications Installation Location A In Humid Area, No Ducting B In Humid Area, Duct Inlet and/or Outlet C In Remote Area, Duct Inlet & Outlet D In Remote Area, Duct Outlet Only E In Remote Area, Duct Inlet Only Electrical Requirements Condensate Removal Ducting A Optional Ducting B Ducting for Dehumidification Dehumidifier Operation Humidity Control On/Off Mode Up/Down Arrows Button Press Tone LED Display Run LED Defrost LED Dehumidify LED Fan LED Digital Display Digital Display Relative Humidity % Digital Display Relative Humidity % Set Point Display Codes Memory/Power Failure Operating Modes Power Up Default Settings After Power Up Dehumidify Mode Changing Modes Fan Mode Standby Mode Protection Functions and Troubleshooting Defrost Protection Defrost Condition Coil Sensor Operating Properly Coil Sensor Malfunction (Digital Display Shows E1) Defrost Cycle Defrost Cycle Complete Conditions A Coil Sensor Operating Properly B Coil Sensor Malfunction (Digital Display Shows E1) C Defrost Cycle LED Dehumidifier Cycle Delayed Start Troubleshooting the Sensors A Coil Sensor B Humidity Sensor Other Functions Control Lock Display Coil Temperature Electromagnetic Compatible Standard EMS Criteria EMC Criteria EMI Criteria Maintenance Air Filter Service Warranty Technical Description Troubleshooting Condensate Pump... 6 Wiring Diagram... 6 Service Parts List... 7 Exploded Parts Diagram... 8 Condensate Pump Installation Instructions... 9 Ductable Inlet Mounting Detail Filter Installation Instructions Warranty Read the installation, operation and maintenance instructions carefully before installing and using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your SaniDry XP dehumidifier. When unpacking, make sure to remove white protective film off of filter rails. 1. Specifications Model: SD109 Blower: " WG Power: F and 60% RH Supply Voltage: 115 volt 1 phase - 60 Hz Current Draw: 6.75 Amps Energy Factor: 2.88 L/kWh Operating Temp.: 40 F Min., 95 F Max. Sized for: 2500 Sq. Ft. - Typical Minimum Performance at 80 F and 60% RH Water Removal: 109 Pints/Day Efficiency: 6.09 Pints/kWh Air Filter: MERV-11 Efficiency: Standard 65% Efficient, ASHRAE Dust Spot Test Size: 16" x 20" x 2" Power Cord: 10', VAC, Ground Drain Hose: 9/16" ID x 8' Direct Gravity Drain Hose SaniDry XP Dimensions Unit With Duct Kit Shipping Width: 19 ¾" 22 ¾" 20¼" Height: 36 ½" 43" 43¼" Depth: 17 ½" 17 ½" 22 5 /8" Weight: 106 lbs 122 lbs 2 SaniDry XP Installer s & Owner s Manual

3 SaniDry XP INSTALLER'S AND OWNER'S MANUAL CAUTION! This symbol means important instructions. Failure to heed them can result in injury or material property damage. 2. Installation 2.1 Location The SaniDry XP is designed to be installed indoors and is ideal for unfinished and finished basements. CAUTION! installation outdoors, or near a pool or spa will void factory warranty. Do not use the dehumidifier as a bench or table. 2.1A In humid area, no ducting. The simplest installation is to place the SaniDry XP in the humid area with no ducting. The air inlet on top & outlet on the side must be at least 1 from walls and other obstructions to air flow. 2.1B In humid area, duct inlet and/or outlet. If the humid area is very large or has high ceilings, dehumidification can be improved by adding an inlet and/or outlet duct to circulate and destratify stagnant areas. For a large area, add inlet or outlet ducting to create flow across the area s greatest length. For areas with ceilings higher than 12, use an inlet duct to draw warm, moist air from near the ceiling. See section 2.4 for attaching duct collars & ducting. 2.1C In A Remote Area, Duct Inlet & Outlet. It is often desirable, in finished areas, to install the SaniDry XP in an adjacent equipment room or unfinished area. Air is transferred between the humid room and the unit via ducting. The factory-mounted humidity control on the SaniDry XP cabinet will sense the humidity in the humid room accurately enough with this installation method. 2.1D In A Remote Area, Duct Outlet Only. A simpler remote installation method than above uses ducting between the SaniDry XP discharge and the humid room; the SaniDry XP inlet draws air from the room in which it s located. This works well if there is an adequate air flow path between the two rooms; i.e. high door undercut, louvered door or wall grill. There are several potential disadvantages to using this method. First, humid air is drawn into the room where the SaniDry XP is located. Second, to accurately sense humidity, the blower in the SaniDry XP may need to run continuously to draw air from the humid room into the SaniDry XP room. Third, a slight negative pressure is created in the room with the SaniDry XP which could backdraft open combustion devices located there. If such devices are present, call the factory for specific instructions before using this installation method or consider the option 2.1E below. 2.1E In A Remote Area, Duct Inlet Only. When the SaniDry XP is located in a room separate from the main area to be dehumidified, it may be desirable to dehumidify and/or slightly pressurize that room. Pressurization assures that open combustion devices do not backdraft. This can be accomplished by installing a duct from the humid room to the SaniDry XP inlet and by allowing the SaniDry XP to discharge dehumidified air into the room in which it s located. An adequate air flow path must exist between the two rooms for this method to work well. 2.2 Electrical Requirements The SaniDry XP plugs into a common grounded outlet on a 15 Amp circuit. It draws between 6 and 7 Amps under normal operating conditions. 2.3 Condensate Removal Condensate drains by gravity via the clear hose extending from the unit. Route hose to a floor drain, sump pump, or drainage system. Use care to keep the hose as flat to the floor as possible. Excessive humps or kinks will prevent proper drainage. If the SaniDry XP is located too far from a floor drain for the attached hose to reach, 1/2" PVC pipe can be used to extend it. It is commonly available in 10 lengths from building supply, plumbing and hardware stores. It will slide tightly inside the end of the drain hose. If more than one length of pipe is required, they can be joined with a short piece cut from the end of the drain hose. 2.4 Ducting 2.4A Optional Ducting An inlet shroud with an 8" round collar and an 8" round exhaust collar are available from the factory that will allow round ducting to be attached to the inlet and/or outlet of the SaniDry XP. 2.4B Ducting for Dehumidification Ducting the SaniDry XP as mentioned in sections 2.1B-2.1E requires consideration of the following points: Duct Sizing: For total duct lengths up to 25 feet, use a minimum 8" diameter round or equivalent rectangular. For longer lengths, use a minimum 10" diameter or equivalent. Grills or diffusers on the duct ends must not excessively restrict air flow. Isolated Areas: Effective dehumidification may require that ducting be branched to isolated, stagnant areas. Use 6" diameter branch ducting to each of two or three areas, use 4" to each of four or more areas. 3. Dehumidifier Operation 3.1 Humidity Control The dehumidifier will run continuously until relative humidity (RH) is reduced to the desired humidity level using the electronic controller. Setting the electronic humidity controller to lower RH levels will NOT increase the unit s dehumidification rate - it will simply run longer to reduce the area s RH to the setting. The SaniDry XP unit (and refrigerant based dehumidifiers in general) will reduce a warm space s RH to a lower level than that of a cool space. For example, the SaniDry XP may reduce an 80 F space to 30% RH. However, if the same space is 65 F, it may only reduce it to 40% RH. It is therefore pointless to set the electronic humidity 3 SaniDry XP Installer s & Owner s Manual

4 SaniDry XP INSTALLER'S AND OWNER'S MANUAL controller to excessively low levels in cool rooms. Doing so will result in long periods of ineffective dehumidifier run time. An ideal setting is 55%, which prevents mold growth. 3.2 ON/OFF: Pressing the ON/OFF button once will power up the control system and illuminate the RED RUN LED. The unit will now operate in either AUTO DEHUMIDIFY or FAN MODE. Pressing the ON/OFF button again will return the unit to STANDBY MODE. The RED RUN LED will flash. 3.3 MODE: Use the MODE button to select AUTO DEHUMIDIFY or FAN mode of operation. 3.4 UP/DOWN ARROWS: Pressing the UP/DOWN arrow buttons will display and change the desired %RH. The selectable %RH range is 26-90%. These buttons will function while in either the AUTO DEHUMIDIFY or FAN MODE. 3.5 BUTTON PRESSING TONE: Pressing any function button will sound a tone. 4. LED DISPLAY 4.1 RUN LED: This RED indicator will flash when in STANDBY MODE. It will remain illuminated while in either AUTO DEHUMIDFY or FAN MODE. 4.2 DEFROST LED: This RED indicator will be illuminated while in the DEFROST MODE, otherwise it will be extinguished. 4.3 AUTO DEHUMIDIFY LED: This GREEN indicator will be illuminated while in the AUTO DEHUMIDIFY MODE, otherwise it will be extinguished. 4.4 FAN LED: This GREEN indicator will be illuminated while in the FAN MODE, otherwise it will be extinguished. 5. DIGITAL DISPLAY 5.1 DIGITAL DISPLAY RELATIVE HUMIDITY %: The digital display will show the current %RH. in the room that the dehumidifier is located while in stand by mode or while running in AUTO DEHUMIDFY or FAN MODES. 5.2 DIGITAL DISPLAY RELATIVE HUMIDITY % SET POINT: The digital display will show the % RH set point when a new setting is selected using the UP/DOWN arrow buttons. 5.3 DISPLAY CODES: E1 indicates that the coil temperature sensor is not functioning properly. E2 indicates that the humidity sensor is not functioning properly. CO indicates that the unit is running in continuous dehumidify mode. 6. MEMORY/POWER FAILURE If a power failure occurs, the unit will store the last selected mode of operation and %RH settings for up to one year. When power returns, the SaniDry XP will resume operation in the mode previously selected. 7. OPERATING MODES: 7.1 POWER UP: When the unit is powered up, it will be in STANDBY MODE indicated by the flashing RED RUN LED. All other LEDs are extinguished. None of the buttons are functional except ON/OFF. The compressor and fan will not run. 7.2 DEFAULT SETTINGS AFTER POWER UP: The control unit displays the current %RH humidity condition of the room and sets the %RH goal to 60%. 7.3 AUTO DEHUMIDIFY MODE: When AUTO DEHUMIDIFY MODE is selected, the GREEN DEHUMIDIFY and RUN RED LED will be lit and the digital display will show the current %RH of the room. The %RH set range is 26-90%. When the set point is lower than the current %RH of the room, the compressor and fan will run. When the current %RH of the room is equal to or less than the set point, the compressor will stop. The fan will continue to run for an additional 30 seconds. When the set point is less than 26%, the digital display will show CO. This indicates that the unit will dehumidify continuously. 7.4 CHANGING MODES: Press the MODE button to change the operating mode from AUTO DEHUMIDIFY to FAN or back to AUTO DEHUMIDIFY. The corresponding LED will be lit to indicate the current operating mode. 7.5 FAN MODE: When the FAN MODE is selected, the fan will run continuously, the GREEN FAN and RED RUN LED'S will be lit, the digital display will show the current %RH of the room. The %RH set range is 26-90%. When the set point is lower than the current %RH of the room, the compressor will run. When the current %RH of the room is equal to or less than the set point, the compressor will stop but the fan will continue to run. 7.6 STANDBY MODE: The unit will return to STANDBY MODE each time the ON/OFF button is pressed to leave the FAN or AUTO DEHUMIDIFY MODES indicated by the flashing RUN RED LED. When running in FAN OR AUTO DEHUMIDIFY MODE and the %RH set point is satisfied, the compressor will shut off, the fan will run for an additional 30 seconds and the defrost timer will be reset. If the ON/OFF button is pressed before the fan shuts off and the unit returns to STANDBY MODE, the compressor will not start when the RUN button is pressed until the this timer has run out. The control unit does not monitor sensor information while in STANDBY MODE. 4 SaniDry XP Installer s & Owner s Manual

5 SaniDry XP INSTALLER'S AND OWNER'S MANUAL 8. PROTECTION FUNCTIONS AND TROUBLESHOOTING CAUTION! electric shock hazard: Maintenance and repairs should be performed by a qualified service person. 8.1 DEFROST PROTECTION 8.2 DEFROST CONDITIONS 8.3 COIL SENSOR OPERATING PROPERLY: While the compressor is running in the AUTO DEHUMIDIFY MODE, the control unit will monitor the coil sensor and measure how much time it sees a coil temperature that is equal to or less than 30 F (-1 C). Once that count reaches 15-minutes, the unit will perform a DEFROST CYCLE. 8.4 COIL SENSOR MALFUNCTIONING (DIGITAL DISPLAY SHOWS E1 ): The unit will perform DEFROST CYCLES after the compressor has run for 53 minutes. 8.5 DEFROST CYCLE: During a DEFROST CYCLE, the compressor will turn off, the fan motor will turn on, the RED DEFROST LED will illuminate and the 15 minute defrost timer will be reset. 8.6 DEFROST CYCLE COMPLETE CONDITIONS 8.6A COIL SENSOR OPERATING PROPERLY: When the coil sensor sees a temperature higher than 37 F (3 C) for 4 minutes, the control unit will exit the DEFROST MODE. 8.6B COIL SENSOR MALFUNCTIONING (DIGITAL DISPLAY SHOWS E1 ): The control unit will execute a DEFROST CYCLE for 6 minutes and then exit the DEFROST MODE. 8.6C The DEFROST CYCLE LED will be extinguished. 8.7 DEHUMIDIFY CYCLE DELAYED START (COMPRESSOR PROTECTION FUNCTION) When the compressor stops running for any reason (%RH set point reached, mode change, power off, power failure, etc.), it will not restart for 3 minutes. When it starts, it will run for a minimum of 5 minutes regardless of the %RH setting. 8.8 TROUBLESHOOTING THE SENSORS CAUTION! electric shock hazard: Maintenance and repairs should be performed by a qualified service person. 8.8A COIL SENSOR: When the coil sensor reports a temperature that is lower than 4 F (-20 C) or higher than 158 F (70 C), the control unit considers it faulty and will display E1 in the digital display. The unit will continue to run in the AUTO DEHUMIDIFY MODE and will perform a DEFROST CYCLE every 53 minutes of operation. 8.8B HUMIDITY SENSOR: When the humidity sensor s output voltage is less than 0.5V or more than 4V, the control unit considers it faulty and will display E2 in the digital display. The unit will run continuously in the AUTO DEHUMIDIFY MODE or FAN MODE and will perform a DEFROST CYCLE as required. 9. OTHER FUNCTIONS 9.1 LOCK: In the RUN mode, pressing the UP/DOWN buttons together for 2 seconds will lock the control. None of the buttons will function except ON/OFF. A decimal point will appear indicating this condition. Pressing the UP/DOWN arrow buttons together for 2 seconds again will unlock the control and restore the all button functions. 9.2 DISPLAY COIL TEMPERATURE: In the RUN mode, pressing the UP arrow button and the MODE button together for 2 seconds will display the coil temperature. Pressing the UP arrow button and the MODE button together for 2 seconds again will return the display to the current %RH of the room. 10. ELECTROMAGNETIC COMPATIBLE STANDARD 10.1 Meets EN electromagnetic compatible EMS criteria 10.2 Meets IEC6100C-4 electromagnetic compatible EMC criteria 10.3 Meets CISPR14 electromagnetic compatible EMI criteria 11. Maintenance 11.1 Air Filter The SaniDry XP is equipped with two (2) air filters. An aluminum/ foam pre-filter followed by a standard MERV-11 65% efficient pleated fabric filter. These should be checked every six months. Operating the unit with dirty filters will reduce dehumidifier capacity and efficiency and may cause the compressor to cycle off and on unnecessarily. If dirty, the aluminum/foam prefilter can be vacuumed or carefully hand washed with warm water and mild detergent then rinsed. The pleated fabric filter can generally be vacuumed clean several times before needing replacement. Replacement filters can be ordered from your local Basement Systems dealer. DO NOT operate the unit without the filters or with a less effective filter. The heat exchange coils inside the unit could become clogged and require disassembly to clean. 5 SaniDry XP Installer s & Owner s Manual

6 SaniDry XP INSTALLER'S AND OWNER'S MANUAL 12. Service CAUTION! Servicing the SaniDry XP with its high-pressure refrigerant system and high-voltage circuitry presents a health hazard which could result in death, serious bodily injury, and/or property damage. Only qualified service people should service this unit Warranty A warranty certificate has been enclosed with this unit. Read it before any repair is initiated. If a warranty repair is required, call the factory first at for warranty claim authorization and technical assistance Technical Description The SaniDry XP uses a refrigeration system similar to an air conditioner s to remove heat and moisture from incoming air and add heat to the air that is discharged (see Figure 1). Hot, high-pressure refrigerant gas is routed from the compressor SaniDry XP WIRING DIAGRAM to the condenser coil (see Figure 1). The refrigerant is cooled and condensed by giving up its heat to the air that is about to be discharged from the unit. The refrigerant liquid then passes through a filter/drier and capillary tubing, which cause the refrigerant pressure and temperature to drop. It next enters the evaporator coil where it absorbs heat from the incoming air and evaporates The evaporator operates in a flooded condition, which means that all the evaporator tubes contain liquid refrigerant during normal operation. A flooded evaporator should maintain constant pressure and temperature across the entire coil, from inlet to outlet. The mixture of gas and liquid refrigerant enter the accumulator after leaving the evaporator coil. The accumulator prevents any liquid refrigerant from reaching the compressor. The compressor evacuates the cool refrigerant gas from the accumulator and compresses it to a high pressure and temperature gas to repeat the process. 13. Condensate Pump The Condensate is automatically pumped to a remote location when the water level in the pump s reservoir rises to close the float switch. Figure 2: Electrical Schematic of the SaniDry XP Dehumidifier 6 SaniDry XP Installer s & Owner s Manual

7 SaniDry XP SERVICE PARTS LIST To order, contact your local Basement Systems Dealer NO DESCRIPTION QTY SPECIFICATIONS 1 Wheel 4 2 Plate, Bottom 1 Galvanized steel (1.5mm) 3 Bracket 4 Galvanized steel (1.0mm) 4 Grommet, rubber compressor 3 Buna N 5 Washer, plate 3 6mm dia. Steel 6 Nut 3 M6 steel 7 Capacitor, compressor 1 35µF/250V 8 Compressor 1 5RS080UAA21 115VAC/60HZ R410A 9 Gasket, cover terminal 1 EPT 10 Spring, hold down 1 SS 11 Overload protector 1 B H 12 Cover, terminal 1 PET 13 Gasket, nut 1 5mm dia PET 14 Cover, terminal nut 1 M5 steel 15 Seal, lower - condenser 1 PU 16 Seal, side condenser 2 PU 17 Condenser 1 18 Seal, upper condenser 1 PU 19 Trough, collection - water 1 SS 20 Probe, temperature 1 21 Evaporator 1 22 Seal, heat exchanger - vertical 4 PU 23 Seal, heat exchanger - horizontal 2 PU 24 Probe, humidity 1 25 Cover, probe - humidity 1 ABS 26 Heat exchanger 1 PP 27 Guide, filter 2 SS (0.6mm) 28 Seal, guide 2 PU 29 Cabinet 1 Powder-coated steel (1.0mm) 30 Bracket, evaporator 1 SS (0.6mm) 31 Tubing, evaporator mm OD x.8mm wall copper tubing 32 Grommet 1 Buna N 33 Capillary 2 2.5mm OD x 1.0mm wall 34 Tubing, discharge mm OD x.8mm wall copper tubing 35 Filter 1 36 Tubing, process mm OD x.8mm wall copper tubing 37 Tubing, condenser mm OD x.8mm wall copper tubing 38 Insulation 1 PE 39 Tubing, suction mm OD x.8mm wall copper tubing 40 Line cord 1 3 wire 16AWG/125V/13A/105 C/300V 41 Cordgrip 1 ABS 42 Grommet 1 Buna N 43 Screen, fan 1 Steel 44 Control unit 1 115V/60Hz 45 Insulation, trough water collection 1 PE 46 Damper, mass 1 47 Housing, fan 1 Powder-coated steel (1.0mm) 48 Motor, fan 1 115V/60Hz 49 Washer, motor - fan 1 Silicon Rubber 97mm OD x 7mm thick 50 Capacitor, fan µF/250V 51 Isolator, vibration - fan 1 PE 52 Rotor, fan 1 Aluminum 53 Deflector, air 1 Powder-coated steel (1.0mm) 54 Wire AWG/105 C/600V/VW-1 55 Clamp, tubing 1 SS 56 Tubing, drain 1 16mm ID x 1.8m PVC 57 Cover, cabinet 1 Powder-coated steel (1.0mm) 58 Insulation, cover - cabinet 1 PE 59 Insulation, cabinet - lower 2 PE 60 Insulation, cabinet - upper 2 PE 61 Filter, pleated paper 1 62 Filter, aluminum 1 7 SaniDry XP Installer s & Owner s Manual

8 SaniDry XP SERVICE PARTS LIST To order, contact your local Basement Systems Dealer Exploded View 8 SaniDry XP Installer s & Owner s Manual

9 SaniDry XP CONDENSATE PUMP INSTALLATION INSTRUCTIONS STEP 1: The condensate pump kit includes: 25' drain hose, drain hose clamp, condensate pump, two mounting screws and instructions. STEP 2: Predrilled mounting holes are located near the bottom and on the same side of the unit as the drain hose. STEP 3: Secure the condensate pump to the unit with the two provided screws. STEP 4: Pull discharge hose out of unit until it stops. Cut the condensate drain hose at a 45 angle approximately 10 inches from the unit. STEP 5: Example of hose cut at a 45 angle. The angle prevents the hose from sealing tight against the bottom of the pump reservoir. STEP 6: Remove the plug as shown. STEP 7: Insert the drain hose into the condensate pump reservoir as shown. STEP 8: Install the provided drain hose over the condensate pump nipple. Tighten hose clamp. STEP 9: Route the condensate pump drain hose to an appropriate drain and plug the condensate pump into a standard 115VAC outlet. 9 SaniDry XP Installer s & Owner s Manual

10 SaniDry XP DUCTABLE INLET MOUNTING Ductable Inlet Instructions 1. Remove the Filters from the unit. 2. Remove the ductable inlet from the box and remove the release paper from the tape on the inlet flanges. 3. Center the inlet above the filter guides and attach the inlet to the guides. 4. Replace the filters in the unit. Exhaust Collar Mounting Instructions 5. Remove the exhaust collar from the box and bend the tabs in. 6. Place the collar over the blower outlet and line up the tabs with the holes in the cabinet. 7. Using (4) screws from the kit, attach the collar to the unit. collar. Ductable Inlet Ductable Inlet Exhaust Collar Exhaust Collar SaniDry XP FILTER INSTALLATION INSTRUCTIONS Instructions: To prevent damaging the aluminum filter, place it mesh-side up on top of the pleated filter and slide them both into the filter slot. Aluminum filter with aluminum grid up. Pleated filter with air flow arrows pointed down. Aluminum mesh filter with aluminum grid up. Pleated filter with air flow arrows pointed down. 10 SaniDry XP Installer s & Owner s Manual

11 SaniDry XP Limited Warranty Limited Warranty. Basement Systems, Inc. ("BSI") warrants as follows: (i) the SaniDry XP dehumidifier ( Product ) will be free of material defects in workmanship or materials for a period of thirty months following the date of manufacture on the cabinet label. Limitation of Remedies. CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THE ABOVE LIMITED WARRANTY AND BSI S ENTIRE LIABILITY THEREUNDER, SHALL BE, AT THE SOLE OPTION OF BSI, REPLACEMENT OR REPAIR OF SUCH PRODUCT OR ITS COMPONENTS ( COMPONENTS ) BY BSI OR BSI S AGENTS ONLY. IF TRANSPORTATION IS REQUIRED TO BASEMENT SYSTEMS' SERVICE CENTER, CUSTOMER MUST PAY FOR SUCH TRANSPORTATION, AND BASEMENT SYSTEMS WILL PAY FOR RETURN TRANSPORTATION BACK TO AUTHORIZED BSI DEALER OR HOMEOWNER ANYWHERE IN CONTINENTAL US OR CANADA. THIS DISCLAIMER AND EXCLUSION SHALL APPLY EVEN IF THE EXPRESS WARRANTY AND LIMITED REMEDY SET FORTH HEREIN FAILS OF ITS ESSENTIAL PURPOSE. CUSTOMER ACKNOWLEDGES THAT NO REPRESENTATIVE OF BSI OR OF ITS AFFILIATES OR RESELLERS IS AUTHORIZED TO MAKE ANY REPRESENTATION OR WARRANTY ON BEHALF OF BSI OR ANY OF ITS AFFILIATES OR RESELLERS THAT IS NOT IN THIS AGREEMENT. Disclaimer of Warranties. EXCEPT FOR ABOVE LIMITED WARRANTY, WHICH IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED WITH RESPECT TO THE PRODUCT AND ITS COMPONENTS, BSI HEREBY DISCLAIMS ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Warranty Limitations. A defect under the terms of the limited warranty shall not include problems resulting from Customer s or Customer s employees, agents, invitees or a third party s misuse, improper installation, improper design of any system in which the Product is included, abuse, lack of normal care, failure to follow written instructions, tampering, improper repair, or freezing, corrosion, acts of nature or other causes not arising out of defects in BSI s workmanship or material. If a Product or Component is replaced while under warranty, the applicable limited warranty period shall not be extended beyond the original warranty time period. The limited warranty does not cover any costs related to changes to a Product or Component that may be required by any codes, laws, or regulations that may become effective after initial purchase of the Product by Customer. Customer Responsibilities. As a further condition to obtaining warranty coverage hereunder, the Customer must send a valid warranty claim to BSI such that BSI receives such claim prior to the end of the applicable warranty period. BSI shall have no obligation hereunder with respect to any claim received by BSI after the expiration of the applicable warranty period. Warranty service must be performed by BSI or a servicer authorized by BSI. In order to obtain warranty service, the Customer should call BSI at and ask for the BSI Products Service Department, which will then arrange for applicable warranty service. Warranty service will be performed during customary, daytime working hours. If the Product must be shipped for service, Customer shall be solely responsible for properly packaging the Product, for all freight charges, and for all risk of loss associated with shipment. Limitation of Liability. IN NO EVENT SHALL BSI, IN CONNECTION WITH THE DESIGN, SALE, INSTALLATION, USE, REPAIR, REPLACEMENT OR PERFORMANCE OF ANY PRODUCT, COMPONENT, PART THEREOF OR WRITTEN MATERIAL PROVIDED THEREWITH, BE LIABLE, TO THE EXTENT ALLOWED UNDER APPLICABLE LAW, UNDER ANY LEGAL THEORY FOR ANY SPECIAL, DIRECT, INDIRECT, COLLATERAL OR CONSEQUENTIAL DAMAGES OF ANY KIND. NOTWITHSTANDING THE ABOVE LIMITATIONS AND WARRANTIES, THE SOLE AND EXCLUSIVE LIABILITY OF BSI, REGARDLESS OF THE NATURE OR THEORY OF THE CLAIM, SHALL UNDER NO CIRCUMSTANCES EXCEED THE PURCHASE PRICE OF THE PRODUCT, COMPONENT OR PART UPON WHICH THE CLAIM IS PREMISED. Applicable Law and Venue. ANY ARBITRATION, ENFORCEMENT OF AN ARBITRATION OR LITIGATION RELATED TO THE PRODUCT WILL BE BROUGHT EXCLUSIVELY IN NEW HAVEN COUNTY, CONNECTICUT, AND CUSTOMER CONSENTS TO THE JURISDICTION OF THE FEDERAL AND STATE COURTS LOCATED THEREIN, SUBMITS TO THE JURISDICTION THEREOF AND WAIVES THE RIGHT TO CHANGE VENUE. CUSTOMER FURTHER CONSENTS TO THE EXERCISE OF PERSONAL JURISDICTION BY ANY SUCH COURT WITH RESPECT TO ANY SUCH PROCEEDING. Miscellaneous. If any term or condition of this Limited Warranty is found by a court of competent jurisdiction to be invalid, illegal or otherwise unenforceable, the same shall not affect the other terms or conditions hereof or thereof or the whole of this Limited Warranty. Any delay or failure by BSI to exercise any right or remedy will not constitute a waiver of BSI to thereafter enforce such rights. By 60 Silvermine Road Seymour, Connecticut Web: For product information go to: Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Basement Systems Basement Systems, Inc. All rights reserved. 11 SaniDry XP Installer s & Owner s Manual

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Dehumidification The highly efficient Ultra-Aire 100V dehumidifier utilizes refrigeration to cool the incoming air stream

More information

Quest 105, Dry155, and 205 Dual

Quest 105, Dry155, and 205 Dual Quest 105, Dry155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

Owner s Manual Phoenix 300

Owner s Manual Phoenix 300 PO Box 8680 Madison, WI 53708 Phoenix 300 High Capacity Dehumidifier Part number TS-218 Owner s Manual Phoenix 300 Installation, Operation and Service Instructions Read and Save These Instructions The

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477

More information

Owner s Manual Phoenix R175 LGR Dehumidifier

Owner s Manual Phoenix R175 LGR Dehumidifier PO Box 8680 Madison, WI 53708 Phoenix R175 LGR Dehumidifier TS-348 Owner s Manual Phoenix R175 LGR Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix

More information

Geyser-R Heat pump water heater Installation manual

Geyser-R Heat pump water heater Installation manual Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed

More information

Owner s Manual Phoenix Arctic Max

Owner s Manual Phoenix Arctic Max PO Box 8680 Madison, WI 53708 Arctic Max TS-388 Owner s Manual Phoenix Arctic Max Installation, Operation and Service Instructions Read and Save These Instructions The new Phoenix Arctic Max is the first

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

AROS SMART WINDOW AIR CONDITIONER

AROS SMART WINDOW AIR CONDITIONER AROS SMART WINDOW AIR CONDITIONER Part of the Quirky + GE collection of smart products, Aros is an app-enabled air conditioning unit that reacts to its surroundings to save you Time, Energy & Money. TABLE

More information

Owner s Manual Phoenix 200 MAX

Owner s Manual Phoenix 200 MAX 420 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix 200 MAX Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 200 MAX is one of the most effective and versatile

More information

www.sylvane.com 1-800-934-9194 4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R200 LGR Dehumidifier

www.sylvane.com 1-800-934-9194 4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R200 LGR Dehumidifier 4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R200 LGR Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix R200 is a compact, energy efficient

More information

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,

More information

HI-E Dry DRY 195. quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. HI-E Dry 195:

HI-E Dry DRY 195. quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. HI-E Dry 195: HI-E Dry DRY 195 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction

More information

Service & Parts Manual

Service & Parts Manual Service & Parts Manual Portable Air Conditioner Models P09B and P2B ( Serial Number Beginning with an "A") Models P09B-A and P2B-A Portable Air conditioner-200 Svc Parts (4-200) Service Points and Flow

More information

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2 Warranty Registration: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty Owner s Manual SRCOOLK (0V, 60 Hz) SRXCOOLK (30V, 50 Hz) Portable Air Conditioning

More information

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat Owner s Manual Portable Air Conditioner with Heat ACW200C / ACW200CH It is important that you read these instructions before using your new purchase and we strongly recommend that you keep them in a safe

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

Owner s Manual Phoenix D385

Owner s Manual Phoenix D385 PO Box 8680 Madison, WI 53708 Phoenix D385 TS-387 Owner s Manual Phoenix D385 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix D385 provides the perfect combination

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION

More information

Important Safeguards

Important Safeguards Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

LOBOY 16 AIR CONDITIONERS

LOBOY 16 AIR CONDITIONERS INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com

More information

INSTANT HOT WATER RECIRCULATING SYSTEM

INSTANT HOT WATER RECIRCULATING SYSTEM INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure

More information

Get Me Cool Now Portable Air Conditioner User s Manual

Get Me Cool Now Portable Air Conditioner User s Manual Get Me Cool Now Portable Air Conditioner User s Manual GMCN100 SERIES Questions or Concerns? Contact technical support department at 1.877.645.0299, 8 a.m. - 5 p.m., EST, Monday - Friday or www.americancomfort.com

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater Portable Air Conditioner / Heater Your Guarantee Instruction Manual For model WA-1220M WA-1220H, WA-1220E P O R T A B L E Air Conditioner If this product is found to be faulty as a result of faulty materials

More information

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

WALL MOUNTED SPLIT TYPE AIR CONDITIONER WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This

More information

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:

More information

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) 216 3330 (55) 1163 6038

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) 216 3330 (55) 1163 6038 Calor de Hogar Av Tecnológico 735, PB San Salvador Tizatlalli Metepec, 52172, Edo de México Teléfono (722) 216 3330 (55) 1163 6038 www.calordehogar.com servicio@calordehogar. com ventas@calordehogar.com

More information

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

WINDOW ROOM AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully

More information

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS FOR AC135, AC150, AC135HP, AC150HP, ACRG12, ACTH12 RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE:

More information

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center

More information

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2 Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H HR SERIES HEAT RECOVERY VENTILATOR (HRV) Home Owners Guide Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR100V HR160H & HR220H READ AND SAVE THIS GUIDE PP0924 09/2013 ABOUT S&P S&P is the world's

More information

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167 PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION

More information

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner OWNERS MANUAL PAC 210 U Portable Windowless Air-Conditioner 1 IMPORTANT INFORMATION When using electrical appliances, basic safety precautions should always be followed, including the following: - Read

More information

Low Cost. Lower Energy Costs. Higher Efficiency.

Low Cost. Lower Energy Costs. Higher Efficiency. HI-E DRY dehumidifiers remove two to three times more water per kilowatt hour of electricity than conventional dehumidifiers. Low Cost. Lower Energy Costs. Higher Efficiency. Therma-Stor designed an efficient,

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner

More information

T-Series Air Conditioner T62 Model

T-Series Air Conditioner T62 Model INSTRUCTION MANUAL T-Series Air Conditioner T62 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t. www.ice-air.com

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t. www.ice-air.com 80 Hartford Avenue Mount Vernon New York 10553 Tel: 914-668-4700 EXT. 203 Fax: 914-668-5643 www.ice-air.com Wo r l d C l a s s C o m f o r t Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE

More information

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Use and Care Manual. Model CPA12KH AIR CONDITIONER Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

OWNER S GUIDE OPERATION & INSTALLATION

OWNER S GUIDE OPERATION & INSTALLATION OWNER S GUIDE OPERATION & INSTALLATION CARRIER RECREATIONAL VEHICLE AIR CONDITIONER PRODUCT INFORMATION Model Number Date in Service Unit Serial Number Ceiling Assembly Serial Number INSTALLER Date of

More information

AROS SMART WINDOW AIR CONDITIONER

AROS SMART WINDOW AIR CONDITIONER AROS SMART WINDOW AIR CONDITIONER Part of the Quirky + GE collection of smart products, Aros is an app-enabled air conditioner that reacts to its surroundings to save you time, energy and money. TABLE

More information

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information Steam Humidifier Model 800 Residential Steam Humidifier Owner s Manual Includes Safety & Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Safety Cautions...

More information

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

Ceiling Mount Air Handler Manual

Ceiling Mount Air Handler Manual www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty

More information

OWNER S Manual PRINTED IN CANADA 10/2009

OWNER S Manual PRINTED IN CANADA 10/2009 OWNER S Manual PRINTED IN CANADA 10/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing

More information

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your

More information

Owner s Manual Phoenix Solution. LGR Performance Amplifier

Owner s Manual Phoenix Solution. LGR Performance Amplifier Owner s Manual Phoenix Solution LGR Performance Amplifier Read And Save These Instructions Phoenix Solution LGR Performance Amplifier Manual Part Number TS-332 The Phoenix Solution is a LGR performance

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 INSTRUCTION MANUAL FOR: T15 AIR CONDITIONER McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleanthermal.com INSTRUCTION MANUAL TABLE OF CONTENTS

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with

More information

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters

More information

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

Wall Mounted Mini Split Heat Pump Air Conditioner

Wall Mounted Mini Split Heat Pump Air Conditioner Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFIHP-09-ID / KFHIP-09-OD KFHHP-12-ID / KFHHP-12-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus

More information

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 FOR SERVICE ASSISTANCE U.S. AND CANADA CALL: 1-877-854-8006 24 HOURS/DAY 7 DAYS/WEEK TABLE OF CONTENTS

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402 TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE

More information

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 T-SERIES Air Conditioners T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 88043249 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND

More information

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN AUTOMATIC S33A1 & S33A1C R WARNING risk of electric shock.

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Operation and Installation Manual. Max Series

Operation and Installation Manual. Max Series Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat

More information

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner This manual covers models: PAC801W, PAC1201W & PAC1401W This manual contains important information regarding safety precautions, and the proper installation, use and maintenance

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation

More information

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions. B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary

More information

Split Air Conditioner

Split Air Conditioner Split nditioner plit itsplit ir onditioner Split Split Split Split Split User s WNER'S 'S ER'S For s: AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1

More information

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation

More information

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference. User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.

More information

Select Radiators Installation Guide

Select Radiators Installation Guide Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall

More information