ACS Proposal - Device Internal Status Log

Size: px
Start display at page:

Download "ACS Proposal - Device Internal Status Log"

Transcription

1 ACS Proposal - Device Internal Status Log July 28, 2010 Revision 3 Author: Nathan Obr 1 Microsoft Way Redmond, WA NatObr@Microsoft.com ACS Proposal - Device Internal Status Log 1

2 Document Status Revision History Rev Date Description 00 May 10, 2010 Investigation of Scope and requirements 0 May 27, 2010 First Draft 1 June 08, 2010 Incorporated Ad Hoc meeting feedback 2 June 23, 2010 Incorporated feedback on the r1 revision from the June T13 meeting 3 July 28, 2010 Incorporated Ad Hoc meetings feedback ACS Proposal - Device Internal Status Log 2

3 1 Introduction Storage is a critical component for computer systems and storage failures are one of the most expensive to address. This is particularly true for enterprise IT. Storage device are sophisticated systems with firmware codebase exceeding 0.5M lines of code, highly tuned electromagnetic media and constantly growing capacities. Greater complexity leads to greater difficulty in diagnosing failures, as well as greater opportunities derived from detailed device logging. One approach to addressing increasing system complexity is enabling a telemetry feedback loop reporting both health monitoring and component failure data for analysis. This benefits users via continuous improvement in manufacturing components as well as software behavior. For high volume manufactured components, telemetry data collection should be thought of as part of the standard engineering process. 2 Scope The purpose of this proposal is to identify and catalog the current goals and requirements for the inclusion of a telemetry mechanism into ATA8-ACS. All section changes are made with reference to d2015r3- ATAATAPI_Command_Set_-_2_ACS-2. It establishes the scope and dataflow that the targeted telemetry system must provide and it proposes a mechanism for notifying and collecting telemetry data from the device at critical times. 3 Overview Enabling telemetry systems creates an opportunity to significantly improve storage experience and perceived reliability for practically all computer applications by enabling device vendors to get internal disk logs through any telemetry system. Creating a closed feedback loop for storage devices in the field will lead to better devices. Continuous connection of vendors to their users experiences can lead to improved quality of the firmware and components Past experience has indicated that some degree of flexibility in size is desired in the collection of telemetry payloads. Issues discovered through telemetry tend to go through 3 phases. Phase 1 establishes that an issue exists in the field and is best accomplished by collecting a minimum set of data to identify the issue as being distinct from other issues. Once the number of instances of an issue grow large enough to prioritize investigation, another phase may be necessary. In Phase 2, a targeted collection of more in depth medium size payloads from the field are gathered and analyzed in order to identify the source of the problem. Finally for those rare few issues that can t be diagnosed by medium size payloads a heroic phase may be justified. In Phase 3, one or two large size payload are collected and analyzed in order to be able to diagnose the issue. An important aspect to issue discovery through telemetry is the ability to qualify distinct issues that are being collected. The ability to create a one to one mapping of issues to payload collections is essential. If a one to one mapping can t be created there is the risk that several payload collections appear distinct but are actually all caused by the same issue. Conversely, a single payload collection may have payloads caused by several issues mixed together making it difficult to understand what the cause of the problem is. The remainder of this section provides a high level description of these aspects of this feature as well as its other uses through timing and dataflow, scope of requirements and goals, and terms defined as necessary. 3.1 Proposed Definition of Terms for Solution Device Internal Status Command: ATA method including command code and parameters that completely defines a single transfer of device internal status data. Device Internal Status Data Header: The standard public portion of the device internal status data returned by the device in response to the Device Internal Status Command. Device Internal Status Data: The vendor specific private portion of the device internal status data returned by ACS Proposal - Device Internal Status Log 3

4 the device in response to the Device Internal Status Command. Device Internal Status Data Type: One of several amounts of device internal status data returned in response to the Device Internal Status Command. 3.2 Device Internal Status Data Collection Requirements Support for the Device Internal Status Command along with Device Internal Status Data Types and their sizes are discoverable. The Device Internal Status Command includes the size of data to be transferred. The Data size applies both the Device Internal Status Data Header and the Device Internal Status Data. The device and host both know the amount of time the device is given before the command will be aborted by the host. The Device Internal Status Data includes a Device Internal Status Data Header which will include: Routing information that can be mapped 1:1 to an organization which should receive the data Routing information that correlates the issue encountered with the proper remedial action to apply to the failing system/device by the host A device identification tag that can be used to associate a specific device to manufacturing data for that specific device Information identifying the host or device as the trigger of the collection of the device internal status data The device is able to notify the host of the presence of an existing device internal status data and its corresponding size during enumeration in a manner that is not dependent on other commands being processed. 3.3 Device Internal Status Data Collection Process Flow Scenario for Current Device Internal Status Data 1. Host determines GPL support in IDENTIFY DEVICE DATA 2. Host determines Device Internal Status Command support and Device Internal Status Data Type sizes from reading GPL address 0, page During a system crash, the host triggers a Device Internal Status Data collection by reading the appropriate Device Internal Status Data pages. i. The device completes the command in quickly (e.g. in less than 1 second). It is recommended that a device respond quickly to avoid users rebooting the system and causing a loss of device state Scenario for Saved Device Internal Status Data 1. Host determines GPL support in IDENTIFY DEVICE DATA 2. Host determines Device Internal Status Command support and Device Internal Status Data Type sizes from reading GPL address 0, page During enumeration, the host determines if there is Device Internal Status Data available by reading page 0, host collects the Device Internal Status Data by reading the corresponding Device Internal Status Data pages. ACS Proposal - Device Internal Status Log 4

5 4 Changes to ACS 4.1 Changes to Annex A - Log Definitions Changes to the Log Address Definitions Table Table A.2 Log Address Definitions Log Address Log Name Feature Set R/W Access 00h Log directory, see A.2 and A.3 N/A RO GPL,SL 01h Summary SMART Error log, see A.17 SMART RO SL 02h Comprehensive SMART Error log, see A.4 SMART RO SL 03h Extended Comprehensive SMART Error Log, SMART RO GPL see A.7 04h Device Statistics, see A.5 N/A RO GPL,SL 05h Reserved for the CompactFlash Association. 06h SMART Self-Test log, see A.16 SMART RO SL 07h Extended SMART Self-Test log, see A.9 SMART RO GPL 08h Power Conditions, see A.8 EPC RO GPL 09h Selective Self-Test log, see A.15 SMART R/W SL 0A-0Ch Reserved N/A Reserved 0Dh LPS Mis-alignment log, see A.11 LPS RO GPL,SL 0Eh-0Fh Reserved 10h NCQ Command Error log, see A.12 NCQ RO GPL 11h SATA Phy Event Counters log, see A.14 N/A RO GPL 12h-17h Reserved for Serial ATA N/A Reserved 18h-1Fh Reserved N/A Reserved 20h Obsolete 21h Write Stream Error log, see A.18 Streaming RO GPL 22h Read Stream Error log, see A.13 Streaming RO GPL 23h Obsolete TBD0 Current Device Internal Status Data Log, see N/A RO GPL A.TBD-A TBD1 Saved Device Internal Status Data Log, see N/A RO GPL A.TBD-B (TBD1+1)-7Fh Reserved N/A Reserved 80h-9Fh Host Specific, see A.10 SMART R/W GPL,SL A0h-9Fh Device Vendor Specific, see A.6 SMART VS GPL,SL E0h SCT Command/Status, see 8.1 SCT R/W GPL,SL E1h SCT Data Transfer, see 8.1 SCT R/W GPL,SL E2h-FFh Reserved N/A Key - RO - Log is read only. R/W - Log is read or written. VS - Log is vendor specific thus read/write ability is vendor specific. GPL - General Purpose Logging SL - SMART Logging Note 1 - The device shall return command aborted if a GPL feature set command accesses a log that is marked only with SL. Note 2 - The device shall return command aborted if a SMART feature set command accesses a log that is marked only with GPL. ACS Proposal - Device Internal Status Log 5

6 4.1.2 New Annex A sub clause TBD-A A.TBD-A Current Device Internal Status Data Log (Log Address TBD0) A.TBD-A.1 Overview The Current Device Internal Status Data Log consists of the Current Device Internal Status Data Header page (see A.TBD-A.2) and zero or more Current Device Internal Status Data pages (see A.TBD-A.3). The current device internal status data is the data representing the internal state of the device at the time the Current Device Internal Status Data log was read with bit 0 in the Feature field set to one. The current device internal status data may be retrieved by one or more reads of pages within the range of 0..n. After a reset, the contents of the Current Device Internal Status Data log are not defined until the Current Device Internal Status Data log has been read with bit 0 in the Feature field set to one. A.TBD-A.2 Current Device Internal Status Data Header Page A.TBD-A.2.1 Current Device Internal Status Data Header Page Overview The Current Device Internal Status Data Header is described in Table A.TBD2. Offset Type Description Table A. TBD2 Current Device Internal Status Data Header (page 0) 0 Byte Log Address 1-3 Bytes Reserved Organization Identifier 4-7 DWord Bit Description 31:24 Reserved 23:0 IEEE OUI 8-9 Word Device Internal Status Data Type 1 Length Word Device Internal Status Data Type 2 Length Word Device Internal Status Data Type 3 Length Bytes Reserved 382 Byte Saved Data Available 383 Byte Saved Data Generation Number Bytes Reason Identifier A.TBD-A.2.2 Log Address The Log Address field shall be set to TBD0. A.TBD-A.2.3 Organization Identifier The Organization Identifier field shall contain an Organization Unique Identifier (OUI) of the organization which is able to interpret the Current Device Internal Status Data in this Log. A.TBD-A.2.4 Device Internal Status Data Type 1 Length The Device Internal Status Data Type 1 Length field identifies the number of pages available within the Device Internal Status Data pages when the device produces Device Internal Status Data of type 1. The value in the Device Internal Status Data Type 1 Length field shall be less than or equal to the value in the Device Internal Status Data Type 2 Length field. ACS Proposal - Device Internal Status Log 6

7 A.TBD-A.2.5 Device Internal Status Data Type 2 Length The Device Internal Status Data Type 2 Length field identifies the number of pages available within the Device Internal Status Data pages when the device produces Device Internal Status Data of type 2. The value in the Device Internal Status Data Type 2 Length field shall be less than or equal to the value in the Device Internal Status Data Type 3 Length field. A.TBD-A.2.6 Device Internal Status Data Type 3 Length The Device Internal Status Data Type 3 Length field identifies the number of pages available within the Device Internal Status Data pages when the device produces Device Internal Status Data of type 3. A.TBD-A.2.7 Saved Data Available If the Saved Device Internal Status Data log is supported, then then the Saved Data Available field shall contain the value of the Saved Data Available field in the Saved Device Internal Status Data log (see A.TBD-B.2.7). If the Saved Device Internal Status Data log is not supported, then the Saved Data Available field shall be reserved. A.TBD-A.2.8 Saved Data Generation Number If the Saved Device Internal Status Data log is supported, then the Generation Number field shall contain the value of the Generation Number field in the Saved Device Internal Status Data log (see A.TBD-B.2.8). If the Saved Device Internal Status Data log is not supported, then the Generation Number field shall be reserved. A.TBD-A.2.9 Reason Identifier The Reason Identifier field contains a vendor specific identifier that describes the operating conditions of the device at the time of capture. The Reason Identifier should provide an identification of different unique operating conditions of the device. A.TBD-A.3 Current Device Internal Status Data Pages The Current Device Internal Status Data in the subsequent pages (see table B.TBD3) of this log shall represent the device internal state. Offset Type Description Table B.TBD3 Current Device Internal Status Data (pages 1..n) Byte Vendor Specific ACS Proposal - Device Internal Status Log 7

8 4.1.3 New Annex A sub clause TBD-B A.TBD-B Saved Device Internal Status Data Log (Log Address TBD1) A.TBD-B.1 Overview The Saved Device Internal Status Data Log consists of a Saved Device Internal Status Data Header page (see A.TBD-B.2) and zero or more Saved Device Internal Status Data pages (see A.TBD-B.3). The saved device internal status data in the Saved Device Internal Status Data log is a device initiated capture of the device internal state. The contents of the Saved Device Internal Status Data log shall persist across all resets. A.TBD-B.2 Saved Device Internal Status Data Header Page A.TBD-B.2.1 Saved Device Internal Status Data Header Page Overview The Saved Device Internal Status Data Header is described in Table B.TBD4. Offset Type Description Table B.TBD4 Saved Device Internal Status Data Header (page 0) 0 Byte Log Address 1-3 Bytes Reserved Organization Identifier 4-7 DWord Bit Description 31:24 Reserved 23:0 IEEE OUI Bytes Device Internal Status Data Type 1 Length Bytes Device Internal Status Data Type 2 Length Bytes Device Internal Status Data Type 3 Length Bytes Reserved 382 Byte Saved Data Available 383 Byte Saved Data Generation Number Bytes Reason Identifier A.TBD-B.2.2 Log Address The Log Address field shall be set to TBD1. A.TBD-B.2.3 Organization Identifier See A.TBD-A.2.3 A.TBD-B.2.4 Device Internal Status Data Type 1 Length See A.TBD-A.2.4 A.TBD-B.2.5 Device Internal Status Data Type 2 Length See A.TBD-A.2.5 A.TBD-B.2.6 Device Internal Status Data Type 3 Length See A.TBD-A.2.6 ACS Proposal - Device Internal Status Log 8

9 A.TBD-B.2.7 Saved Data Available If the Saved Data Available field is cleared to 00h, then the Saved Device Internal Status Data log does not contain saved Device Internal Status Data. If the Saved Data Available field is set to 01h, then the Saved Device Internal Status Data log contains Saved Device Internal Status Data. If any page of the Saved Device Internal Status Data in the Saved Device Internal Status Data log is read, then the Saved Data Available field shall be cleared to 00h. If the device saves Saved Device Internal Status Data in the Saved Device Internal Status Data log, then the Saved Data Available field shall be set to 01h. A.TBD-B.2.8 Saved Data Generation Number The Generation Number field shall contain a value that is incremented when the device initiates a capture of its internal device state into the Saved Device Internal Status Data. A.TBD-B.2.9 Reason Identifier See A.TBD-A.2.9 A.TBD-B.3 Saved Device Internal Status Data Pages The Saved Device Internal Status Data in the subsequent pages (see table B.TBD5) of this log shall represent the device internal state. Offset Type Description Byte Vendor Specific Table B.TBD5 Saved Device Internal Status Data (pages 1..n) ACS Proposal - Device Internal Status Log 9

ACS-3 Reporting Security Compliance

ACS-3 Reporting Security Compliance October 5, 2010 T13/e09151r2 October 5, 2010 Revision 2 Technical Editor: Jim Hatfield 389 Disc Drive Longmont, CO 80503 720-684-2120 James.C.Hatfield@Seagate.com Page 1 of 8 T13/e09151r2 October 5, 2010

More information

Device Statistics Transport

Device Statistics Transport Device Statistics Transport By Steve Livaccari, IBM, and Joseph Chen, Samsung Revision 6, 2008-06-23 [This document is a proposal for the T13 to describe the Device Statistics for the device to report.

More information

Programming Interface. for. Bus Master IDE Controller. Revision 1.0

Programming Interface. for. Bus Master IDE Controller. Revision 1.0 Programming Interface for Bus Master IDE Controller Revision 1.0 5/16/94 Until this specification is ratified, it is solely owned and maintained by: Brad Hosler, Intel Corporation bwh@salem.intel.com (please

More information

Intel Solid State Drive Toolbox

Intel Solid State Drive Toolbox 3.3.6 Document Number: 325993-027US Intel technologies features and benefits depend on system configuration and may require enabled hardware, software or service activation. Performance varies depending

More information

Information technology - AT Attachment 8 - ATA/ATAPI Command Set (ATA8-ACS)

Information technology - AT Attachment 8 - ATA/ATAPI Command Set (ATA8-ACS) Working Draft Project American National Standard T13/1699-D Revision 3f December 11, 2006 Information technology - AT Attachment 8 - ATA/ATAPI Command Set (ATA8-ACS) This is a draft proposed American National

More information

Intel Solid-State Drive 320 Series

Intel Solid-State Drive 320 Series Intel Solid-State Drive 320 Series Enterprise Server/Storage Application Product Specification Addendum Form Factors: 1.8-inch and 2.5-inch Capacity: 80/160/300 GB (1.8-inch) 40/80/120/160/300/600 GB (2.5-inch)

More information

Verifying Detection of Asset Tags in WLAN Controllers

Verifying Detection of Asset Tags in WLAN Controllers APPENDIXB Verifying Detection of Asset Tags in WLAN Controllers Asset Tags Detection The protocol analyzer trace in Figure B-1 provides important information with regard to how asset tags compliant with

More information

Intel Solid State Drive Toolbox

Intel Solid State Drive Toolbox 3.3.5 Document Number: 325993-026US Intel technologies features and benefits depend on system configuration and may require enabled hardware, software or service activation. Performance varies depending

More information

LENORD. +BAUER... automates motion. Fieldbus connection absolute encoders CANopen. Reference. Communication profile DS-301 Device profile DS-406

LENORD. +BAUER... automates motion. Fieldbus connection absolute encoders CANopen. Reference. Communication profile DS-301 Device profile DS-406 Fieldbus connection absolute encoders CANopen Communication profile DS-30 Device profile DS-406 LENORD +BAUER... automates motion. Reference D-0R-xCO (.) Right to technical changes and errors reserved.

More information

S4000TH HART. HART Communication Manual

S4000TH HART. HART Communication Manual HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by General

More information

Samsung SSD 840 PRO Series.

Samsung SSD 840 PRO Series. , May. 2013 MZ-7PD512 MZ-7PD128 Samsung SSD. datasheet DISCLAIMER SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE PRODUCTS, INFORMATION AND SPECIFICATIONS WITHOUT NOTICE. Products and specifications discussed

More information

SCSI Commands Reference Manual

SCSI Commands Reference Manual SCSI Commands Reference Manual Parallel SCSI Fibre Channel (FC) Serial Attached SCSI (SAS) Rev. A SCSI Commands Reference Manual Parallel SCSI Fibre Channel (FC) Serial Attached SCSI (SAS) Rev. A 2006,

More information

SCSI Commands Reference Manual

SCSI Commands Reference Manual Product Manual SCSI Commands Reference Manual Parallel SCSI Fibre Channel (FC) Serial Attached SCSI (SAS) 100293068 Rev. C April 2010 2010 Seagate Technology LLC. All rights reserved. Publication number:

More information

Difference between Enterprise SATA HDDs and Desktop HDDs. Difference between Enterprise Class HDD & Desktop HDD

Difference between Enterprise SATA HDDs and Desktop HDDs. Difference between Enterprise Class HDD & Desktop HDD In order to fulfil the operational needs, different web hosting providers offer different models of hard drives. While some web hosts provide Enterprise HDDs, which although comparatively expensive, offer

More information

HP Notebook Hard Drives & Solid State Drives. Identifying, Preventing, Diagnosing and Recovering from Drive Failures. Care and Maintenance Measures

HP Notebook Hard Drives & Solid State Drives. Identifying, Preventing, Diagnosing and Recovering from Drive Failures. Care and Maintenance Measures HP Notebook Hard Drives & Solid State Drives Identifying, Preventing, Diagnosing and Recovering from Drive Failures Care and Maintenance Measures Technical White Paper Table of contents Identifying, Preventing,

More information

EMC RepliStor for Microsoft Windows ERROR MESSAGE AND CODE GUIDE P/N 300-002-826 REV A02

EMC RepliStor for Microsoft Windows ERROR MESSAGE AND CODE GUIDE P/N 300-002-826 REV A02 EMC RepliStor for Microsoft Windows ERROR MESSAGE AND CODE GUIDE P/N 300-002-826 REV A02 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2003-2005

More information

M510DC 2.5-Inch TCG Enterprise SATA NAND Flash SSD

M510DC 2.5-Inch TCG Enterprise SATA NAND Flash SSD M510DC 2.5-Inch TCG Enterprise SATA NAND Flash SSD MTFDDAK120MBP, MTFDDAK240MBP, MTFDDAK480MBP, MTFDDAK800MBP, MTFDDAK960MBP M510DC 2.5-Inch NAND Flash SSD Features Features Micron 16nm MLC NAND Flash

More information

4K Sector Disk Drives: Transitioning to the Future with Advanced Format Technologies

4K Sector Disk Drives: Transitioning to the Future with Advanced Format Technologies 4K Sector Disk Drives: Transitioning to the Future with Advanced Format Technologies By Michael E. Fitzpatrick, Engineering Fellow, Storage Products Marketing Toshiba America Information Systems, Inc.

More information

Smart Business Architecture for Midsize Networks Network Management Deployment Guide

Smart Business Architecture for Midsize Networks Network Management Deployment Guide Smart Business Architecture for Midsize Networks Network Management Deployment Guide Introduction: Smart Business Architecture for Mid-sized Networks, Network Management Deployment Guide With the Smart

More information

UG103.5 EMBER APPLICATION DEVELOPMENT FUNDAMENTALS: SECURITY

UG103.5 EMBER APPLICATION DEVELOPMENT FUNDAMENTALS: SECURITY EMBER APPLICATION DEVELOPMENT FUNDAMENTALS: SECURITY This document introduces some basic security concepts, including network layer security, trust centers, and application support layer security features.

More information

P400m 2.5-Inch SATA NAND Flash SSD

P400m 2.5-Inch SATA NAND Flash SSD P400m 2.5-Inch SATA NAND Flash SSD MTFDDAK100MAN-1S1AA, MTFDDAK200MAN-1S1AA, MTFDDAK400MAN-1S1AA P400m 2.5-Inch NAND Flash SSD Features Features Micron 25nm MLC NAND Flash RoHS-compliant package SATA 6

More information

How To Configure Voice Vlan On An Ip Phone

How To Configure Voice Vlan On An Ip Phone 1 VLAN (Virtual Local Area Network) is used to logically divide a physical network into several broadcast domains. VLAN membership can be configured through software instead of physically relocating devices

More information

Kingston Technology SSDNow V+100E (Full Disk Encryption) Flash Storage Drive

Kingston Technology SSDNow V+100E (Full Disk Encryption) Flash Storage Drive Kingston Technology SSDNow V+E (Full Disk Encryption) Flash Storage Drive This product description of the SSDNow Solid State flash drive is provided by Kingston, and is applicable for all Kingston's V+E

More information

Application Note. Introduction AN2471/D 3/2003. PC Master Software Communication Protocol Specification

Application Note. Introduction AN2471/D 3/2003. PC Master Software Communication Protocol Specification Application Note 3/2003 PC Master Software Communication Protocol Specification By Pavel Kania and Michal Hanak S 3 L Applications Engineerings MCSL Roznov pod Radhostem Introduction The purpose of this

More information

Technical Note. SFDP for MT25Q Family. Introduction. TN-25-06: Serial Flash Discovery Parameters for MT25Q Family. Introduction

Technical Note. SFDP for MT25Q Family. Introduction. TN-25-06: Serial Flash Discovery Parameters for MT25Q Family. Introduction Technical Note SFDP for MT25Q Family TN-25-06: Serial Flash Discovery Parameters for MT25Q Family Introduction Introduction The serial Flash discoverable parameter (SFDP) standard enables a consistent

More information

Technical Proposal on ATA Secure Erase Gordon Hughes+ and Tom Coughlin* +CMRR, University of California San Diego *Coughlin Associates

Technical Proposal on ATA Secure Erase Gordon Hughes+ and Tom Coughlin* +CMRR, University of California San Diego *Coughlin Associates Technical Proposal on ATA Secure Erase Gordon Hughes+ and Tom Coughlin* +CMRR, University of California San Diego *Coughlin Associates Introduction and Summary Secure erase SE is defined in the ATA specification

More information

Methode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly. www.methode.com

Methode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly. www.methode.com DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly Compliant with Infiniband Architecture Specification Annex 6 Hot-pluggable footprint Supports Serial ID (write protected) Robust Die Cast Housing

More information

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies Agilent Technologies USB/LAN/GPIB Interfaces Connectivity Guide Agilent Technologies Notices Agilent Technologies, Inc. 2003, 2004 No part of this manual may be reproduced in any form or by any means (including

More information

Chapter 9: Peripheral Devices: Magnetic Disks

Chapter 9: Peripheral Devices: Magnetic Disks Chapter 9: Peripheral Devices: Magnetic Disks Basic Disk Operation Performance Parameters and History of Improvement Example disks RAID (Redundant Arrays of Inexpensive Disks) Improving Reliability Improving

More information

AD Account Lockout Investigation and Root Cause Analysis

AD Account Lockout Investigation and Root Cause Analysis AD Account Lockout Investigation and Root Cause Analysis Allen Chin Principal Consultant allen_chin@symantec.com 1 Contents 1 Background Issue 2 What was done 3 What were discovered 4 Recommendations 5

More information

HOW LYNC 2010 & LYNC 2013 GETS USER CONTACT CARD PHOTO

HOW LYNC 2010 & LYNC 2013 GETS USER CONTACT CARD PHOTO Prior Lync 2010, Live Communications Server 2003, Live Communications Server 2005 and Office Communications Server 2007 Unified Communication and Collaboration products did not offer a feature that displays

More information

Reducing Storage Energy Consumption by up to 75%

Reducing Storage Energy Consumption by up to 75% Technology Paper Reducing Storage Energy Introduction While the challenging economic climate continues to exert downward pressure on enterprise IT investment, there is one key exception to this trend.

More information

Intelligent Monitoring Configuration Tool

Intelligent Monitoring Configuration Tool Intelligent Monitoring Configuration Tool User Guide Software Version 1.0 and above EZPlugger 2004 Sony Corporation Copyright Notice 2004 Sony Corporation. All rights reserved. This manual may not be

More information

Volume Serial Numbers and Format Date/Time Verification

Volume Serial Numbers and Format Date/Time Verification Volume Serial Numbers and Format Date/Time Verification Written by Craig Wilson, MSc MBCS CITP Digital Detective Group October 2003 (updated June 2005) Table of Contents Table of Contents... 2 Introduction...

More information

ProSafe Plus Switch Utility

ProSafe Plus Switch Utility ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA September 2010 202-10524-03 v1.0 ProSafe Plus Switch Utility User Guide 2010 NETGEAR, Inc. All rights reserved. No

More information

Authorization for ACH Transfer

Authorization for ACH Transfer Authorization for ACH Transfer New Automatic Transfer Change Existing Transfer Cancel Existing Transfer Institution Name Wells Fargo Bank, N.A. Transfer From Account Name Account Number Transfer To Name

More information

ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK

ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK KEY FEATURES PROVISION FROM BARE- METAL TO PRODUCTION QUICKLY AND EFFICIENTLY Controlled discovery with active control of your hardware Automatically

More information

A Guide to Understanding SNMP

A Guide to Understanding SNMP A Guide to Understanding SNMP Read about SNMP v1, v2c & v3 and Learn How to Configure SNMP on Cisco Routers 2013, SolarWinds Worldwide, LLC. All rights reserved. Share: In small networks with only a few

More information

ExpressSAS Host Adapter 6Gb v2.15 Linux

ExpressSAS Host Adapter 6Gb v2.15 Linux Product Release Notes ExpressSAS Host Adapter 6Gb v2.15 Linux 1. General Release Information These product release notes define the new features, changes, known issues and release details that apply to

More information

Modicon Modbus Protocol Reference Guide. PI MBUS 300 Rev. J

Modicon Modbus Protocol Reference Guide. PI MBUS 300 Rev. J Modicon Modbus Protocol Reference Guide PI MBUS 300 Rev. J 1 Modicon Modbus Protocol Reference Guide PI MBUS 300 Rev. J June 1996 MODICON, Inc., Industrial Automation Systems One High Street North Andover,

More information

1 Overview. T10/03-176 revision 9

1 Overview. T10/03-176 revision 9 Date: October 22, 2003 To: T10 Committee (SCSI) From: George Penokie (IBM/Tivoli) Subject: End-to-End Data Protection 1 Overview Any inconsistencies between this section and the remaining sections in the

More information

This text refers to the 32bit version of Windows, unfortunately I don't have access to a 64bit development environment.

This text refers to the 32bit version of Windows, unfortunately I don't have access to a 64bit development environment. Windows 7/2008 Event Log forensic and reversing analysis eseugutrop Reversed 2011/03/16 by ar1vr This text refers to the 32bit version of Windows, unfortunately I don't have access to a 64bit development

More information

Intrepid 3600 Enterprise SSD

Intrepid 3600 Enterprise SSD Enterprise SSD 2.5 Solid-State Drive IT3RSK41MT3XX-xxxx The OCZ 2.5 Intrepid 3000 Series of Solid State Drives are designed specifically to address Enterprise storage and computing applications where demanding

More information

SAMSUNG SSD 845DC PRO Data Sheet, Ver. 1.0

SAMSUNG SSD 845DC PRO Data Sheet, Ver. 1.0 SAMSUNG SSD 845DC PRO Data Sheet, Ver. 1.0 DISCLAIMER SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE PRODUCTS, INFORMATION AND SPECIFICATIONS WITHOUT NOTICE. Products and specifications discussed herein

More information

Serial Communications Protocol. Data 2179 Revision 4. For Use With Cooper Power Systems Apparatus Controls: Form 6 Recloser Control

Serial Communications Protocol. Data 2179 Revision 4. For Use With Cooper Power Systems Apparatus Controls: Form 6 Recloser Control Controls Serial Communications Protocol Reference Information R28-9-2 Serial Communications Protocol Data 279 Revision 4 For Use With Cooper Power Systems Apparatus Controls: Form 6 Recloser Control Form

More information

Intrepid 3800 Enterprise SSD

Intrepid 3800 Enterprise SSD Enterprise SSD 2.5 Solid-State Drive IT3RSK41ET3XX-xxxx The OCZ 2.5 Intrepid 3000 Series of Solid State Drives are designed specifically to address Enterprise storage and computing applications where demanding

More information

Windows Server 2003 default services

Windows Server 2003 default services Windows Server 2003 default services To view a description for a particular service, hover the mouse pointer over the service in the Name column. The descriptions included here are based on Microsoft documentation.

More information

AXI Performance Monitor v5.0

AXI Performance Monitor v5.0 AXI Performance Monitor v5.0 LogiCORE IP Product Guide Vivado Design Suite Table of Contents IP Facts Chapter 1: Overview Advanced Mode...................................................................

More information

Saber 1000 Series. Enterprise SSD. 2.5 Solid-State Drive. SB1CSK31MT5XX-xxxx. SSD Datasheet

Saber 1000 Series. Enterprise SSD. 2.5 Solid-State Drive. SB1CSK31MT5XX-xxxx. SSD Datasheet Saber 1000 Series Enterprise SSD 2.5 Solid-State Drive SB1CSK31MT5XX-xxxx The OCZ 2.5 of Solid State Drives are designed specifically to address Enterprise storage and computing applications where demanding

More information

Web Application Hacking (Penetration Testing) 5-day Hands-On Course

Web Application Hacking (Penetration Testing) 5-day Hands-On Course Web Application Hacking (Penetration Testing) 5-day Hands-On Course Web Application Hacking (Penetration Testing) 5-day Hands-On Course Course Description Our web sites are under attack on a daily basis

More information

Strategies for Firmware Support of Self-Encrypting Drives

Strategies for Firmware Support of Self-Encrypting Drives presented by Strategies for Firmware Support of Self-Encrypting Drives UEFI Winter Plugfest February 21-23, 2011 Presented by Jeff Bobzin (Insyde Software, Inc.) Updated 2011-06-01 UEFI Plugfest February

More information

PCmover Enterprise User Guide

PCmover Enterprise User Guide Laplink Software, Inc. PCmover Enterprise User Guide The Only Software that Moves Programs, Files, and Settings to a New PC! MN-PCMVENTPR-EN (REV. 1/12) Laplink Software, Inc. For technical support issues

More information

Intel Solid State Drive Data Center Tool

Intel Solid State Drive Data Center Tool User Guide Software Version 3.0.x Document Number: 331961-006US Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or

More information

The Windows Shortcut File Format as reverse-engineered by Jesse Hager jessehager@iname.com Document Version 1.0

The Windows Shortcut File Format as reverse-engineered by Jesse Hager jessehager@iname.com Document Version 1.0 Disclaimer The Windows Shortcut File Format as reverse-engineered by Jesse Hager jessehager@iname.com Document Version 1.0 This document is provided AS-IS basis, without any warranties or representations

More information

Enterprise-class versus Desktop-class Hard Drives

Enterprise-class versus Desktop-class Hard Drives Enterprise-class versus Desktop-class Hard Drives A document providing a comparison between enterprise-class and desktop-class hard drives Rev 2.0 April 2016 Intel Server Boards and Systems

More information

BUYER S GUIDE: PC INVENTORY AND SOFTWARE USAGE METERING TOOLS

BUYER S GUIDE: PC INVENTORY AND SOFTWARE USAGE METERING TOOLS BUYER S GUIDE: PC INVENTORY AND SOFTWARE USAGE METERING TOOLS A guide for identifying an IT/software asset management product that best meets the needs of your organization 200 West Mercer Street Suite

More information

ZooKeeper. Table of contents

ZooKeeper. Table of contents by Table of contents 1 ZooKeeper: A Distributed Coordination Service for Distributed Applications... 2 1.1 Design Goals...2 1.2 Data model and the hierarchical namespace...3 1.3 Nodes and ephemeral nodes...

More information

Modbus and ION Technology

Modbus and ION Technology 70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible

More information

CA Nimsoft Monitor. Probe Guide for Active Directory Server. ad_server v1.4 series

CA Nimsoft Monitor. Probe Guide for Active Directory Server. ad_server v1.4 series CA Nimsoft Monitor Probe Guide for Active Directory Server ad_server v1.4 series Legal Notices Copyright 2013, CA. All rights reserved. Warranty The material contained in this document is provided "as

More information

AMD SP5100 Dot Hill SATA RAID Users Manual V100

AMD SP5100 Dot Hill SATA RAID Users Manual V100 AMD SP5100 Dot Hill SATA RAID Users Manual V100 1 Table of Contents Section 1 Dot Hill Firmware Overview Firmware Overview Page 3 Firmware Option Rom/Firmware Overview Page 3 Firmware Menus Page 4 Initialize

More information

Microsoft Windows 2000 Terminal Services

Microsoft Windows 2000 Terminal Services Operating System Microsoft Windows 2000 Terminal Services Licensing Technology White Paper Abstract This white paper provides an introduction to Terminal Services Licensing, the client license management

More information

Linux Driver Devices. Why, When, Which, How?

Linux Driver Devices. Why, When, Which, How? Bertrand Mermet Sylvain Ract Linux Driver Devices. Why, When, Which, How? Since its creation in the early 1990 s Linux has been installed on millions of computers or embedded systems. These systems may

More information

AppMetrics for Transactions SCOM Management Pack Users Guide

AppMetrics for Transactions SCOM Management Pack Users Guide AppMetrics for Transactions SCOM Management Pack Users Guide Introduction SCOM Overview System Center Operations Manager enables data center operations personnel to monitor state, performance, and health

More information

Taking Linux File and Storage Systems into the Future. Ric Wheeler Director Kernel File and Storage Team Red Hat, Incorporated

Taking Linux File and Storage Systems into the Future. Ric Wheeler Director Kernel File and Storage Team Red Hat, Incorporated Taking Linux File and Storage Systems into the Future Ric Wheeler Director Kernel File and Storage Team Red Hat, Incorporated 1 Overview Going Bigger Going Faster Support for New Hardware Current Areas

More information

SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System

SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System with Internal Storage Focusing on IPMI Out of Band Management Recipe ID: 19SYAM190000000011-01 Contents Hardware Components...3

More information

STAR Watch Statewide Technology Assistance Resources Project A publication of the Western New York Law Center,Inc. Volume 9 Issue 2 March/April 2005

STAR Watch Statewide Technology Assistance Resources Project A publication of the Western New York Law Center,Inc. Volume 9 Issue 2 March/April 2005 STAR Watch Statewide Technology Assistance Resources Project A publication of the Western New York Law Center,Inc. Volume 9 Issue 2 March/April 2005 Hard Drive Capacity: How much do you really need? Computer

More information

SAN Conceptual and Design Basics

SAN Conceptual and Design Basics TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer

More information

2.5" SATA 6.0Gb/s MLC SSD SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE PRODUCTS, INFORMATION AND SPECIFICATIONS WITHOUT NOTICE.

2.5 SATA 6.0Gb/s MLC SSD SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE PRODUCTS, INFORMATION AND SPECIFICATIONS WITHOUT NOTICE. , Sep. 2011 MZ7PC512HAGH-00000 MZ7PC256HAFU-00000 MZ7PC128HAFU-00000 MZ7PC064HADR-00000 2.5" SATA 6.0Gb/s MLC SSD (NAND based Solid State Drive) datasheet SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE

More information

Firmware for All Cisco s SIP Phones (requires Cisco login): http://www.cisco.com/kobayashi/sw-center/sw-voice.shtml

Firmware for All Cisco s SIP Phones (requires Cisco login): http://www.cisco.com/kobayashi/sw-center/sw-voice.shtml Cisco 7940 and 7960 IP Phones 1 Warnings Check the SIP 3 rd Party Validation website for certification status. It can be located at: http://testlab.inin.com Vendor Documentation Cisco SIP products: http://www.cisco.com/warp/public/cc/techno/tyvdve/sip/

More information

DATE: 8th July, 2001 Erica Williamsen, Bob Noseworthy COMPANY/AFFILIATION: UNH InterOperability Lab ericaw@iol.unh.edu, ren@iol.unh.

DATE: 8th July, 2001 Erica Williamsen, Bob Noseworthy COMPANY/AFFILIATION: UNH InterOperability Lab ericaw@iol.unh.edu, ren@iol.unh. +----------------------------------------------------------------------+ 0-/0. REVISION REQUEST 0 +---------------====================================-------------------+ DATE: th July, 00 NAME: Erica

More information

Industrial Flash Storage Trends in Software and Security

Industrial Flash Storage Trends in Software and Security January 22, 2013 Industrial Flash Storage Trends in Software and Security Many flash storage devices in embedded applications are used to save data but also function as disks for the OS. Most users are

More information

SSL-Manager (SNMP-SSL Management Software)

SSL-Manager (SNMP-SSL Management Software) SSL-Manager (SNMP-SSL Management Software) User s Manual Table of Contents Chapter 1 Introduction... 3 Chapter 2 Installation... 4 Chapter 3 SSL-Manager Menus... 8 Chapter 4 Setup... 11 Chapter 5 Operation...

More information

Where Are My Primary Documents?

Where Are My Primary Documents? Where Are My Primary Documents? Even though a document has been assigned to the Hermeneutic Unit and I have already worked with it (coded, etc.) and it shows up in the list of primary documents, it no

More information

Modbus and ION Technology

Modbus and ION Technology Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. ACCESS meters are compatible with Modbus networks as both slaves and

More information

DLT Event Log Troubleshooting Guide 3/07/00

DLT Event Log Troubleshooting Guide 3/07/00 DLT Event Log Troubleshooting Guide 3/07/00 Quantum Corporation DLT DLTtape DLTstor Page 1 A.0 How to Use this Document This manual supports the DLT 8000, DLT 7000, DLT 4000, DLT 2000XT, and DLT 2000.

More information

Version 1.5 Satlantic Inc.

Version 1.5 Satlantic Inc. SatCon Data Conversion Program Users Guide Version 1.5 Version: 1.5 (B) - March 09, 2011 i/i TABLE OF CONTENTS 1.0 Introduction... 1 2.0 Installation... 1 3.0 Glossary of terms... 1 4.0 Getting Started...

More information

Site Master S251B Antenna and Cable Analyzer

Site Master S251B Antenna and Cable Analyzer Site Master S251B Antenna and Cable Analyzer Programming Manual Hand-Held Tester For Antennas, Transmission Lines And Other RF Components WARRANTY The Anritsu product(s) listed on the title page is (are)

More information

Drobo How-To Guide. Topics. What You Will Need. Configure Windows iscsi Multipath I/O (MPIO) with Drobo iscsi SAN

Drobo How-To Guide. Topics. What You Will Need. Configure Windows iscsi Multipath I/O (MPIO) with Drobo iscsi SAN Multipath I/O (MPIO) enables the use of multiple iscsi ports on a Drobo SAN to provide fault tolerance. MPIO can also boost performance of an application by load balancing traffic across multiple ports.

More information

Lesson Objectives. To provide a grand tour of the major operating systems components To provide coverage of basic computer system organization

Lesson Objectives. To provide a grand tour of the major operating systems components To provide coverage of basic computer system organization Lesson Objectives To provide a grand tour of the major operating systems components To provide coverage of basic computer system organization AE3B33OSD Lesson 1 / Page 2 What is an Operating System? A

More information

Cache Configuration Reference

Cache Configuration Reference Sitecore CMS 6.2 Cache Configuration Reference Rev: 2009-11-20 Sitecore CMS 6.2 Cache Configuration Reference Tips and Techniques for Administrators and Developers Table of Contents Chapter 1 Introduction...

More information

Intel 8255x 10/100 Mbps Ethernet Controller Family

Intel 8255x 10/100 Mbps Ethernet Controller Family Intel 8255x 10/100 Mbps Ethernet Controller Family Open Source Software Developer Manual January 2006 Revision 1.3 Information in this document is provided in connection with Intel products. This specification,

More information

my forecasted needs. The constraint of asymmetrical processing was offset two ways. The first was by configuring the SAN and all hosts to utilize

my forecasted needs. The constraint of asymmetrical processing was offset two ways. The first was by configuring the SAN and all hosts to utilize 1) Disk performance When factoring in disk performance, one of the larger impacts on a VM is determined by the type of disk you opt to use for your VMs in Hyper-v manager/scvmm such as fixed vs dynamic.

More information

StreamServe Persuasion SP5 Microsoft SQL Server

StreamServe Persuasion SP5 Microsoft SQL Server StreamServe Persuasion SP5 Microsoft SQL Server Database Guidelines Rev A StreamServe Persuasion SP5 Microsoft SQL Server Database Guidelines Rev A 2001-2011 STREAMSERVE, INC. ALL RIGHTS RESERVED United

More information

Easy Smart Configuration Utility

Easy Smart Configuration Utility Easy Smart Configuration Utility REV1.1.0 1910010977 CONTENTS Chapter 1 About this Guide...1 1.1 Intended Readers... 1 1.2 Conventions... 1 1.3 Overview of This Guide... 1 Chapter 2 Getting Started...4

More information

-------------------------------------------------------------------- README.TXT

-------------------------------------------------------------------- README.TXT README.TXT ICP ICP9085LI/ICP5085BR SAS RAID Controller ICP ICP9047MA/ICP9087MA SATA RAID Controller ICP ICP9014RO/ICP9024RO SCSI RAID Controller ICP ICP5805BL/ICP5045BL/ICP5085BL/ICP5125BR/ICP5165BR Unified

More information

Product Specification

Product Specification July 2013 Product Specification Industrial 1.8 micro SATA II SLC SSD -HERMES-ER Series- Doc-No: 100-XP8SR-JESL-01V0 This document is for information use only and is subject to change without prior notice.

More information

Implementation and Implications of a Stealth Hard-Drive Backdoor

Implementation and Implications of a Stealth Hard-Drive Backdoor March 3rd 2014 OSSIR/JSSI 2014 Paper first presented at ACSAC 2013 Awarded Best Student Paper Award Implementation and Implications of a Stealth Hard-Drive Backdoor Jonas Zaddach Davide Balzarotti Aure

More information

Using Windows 2008 RADIUS Authentication with Tripp Lite SNMPWEBCARD

Using Windows 2008 RADIUS Authentication with Tripp Lite SNMPWEBCARD Using Windows 2008 RADIUS Authentication with Tripp Lite SNMPWEBCARD December 11, 2012 Summary This Technical Bulletin describes how to configure Microsoft RADIUS Server for authenticating users for access

More information

ES_LPC4357/53/37/33. Errata sheet LPC4357/53/37/33. Document information

ES_LPC4357/53/37/33. Errata sheet LPC4357/53/37/33. Document information Rev. 1.1 8 August 2012 Errata sheet Document information Info Keywords Abstract Content LPC4357FET256; LPC4357FET180; LPC4357FBD208; LPC4353FET256; LPC4353FET180; LPC4353FBD208; LPC4337FET256; LPC4337FET180;

More information

Enterprise-class versus Desktopclass

Enterprise-class versus Desktopclass Enterprise-class versus Desktopclass Hard Drives April, 2008 Enterprise Platforms and Services Division - Marketing Revision History Date Revision Number April, 2008 1.0 Initial Release Modifications Disclaimers

More information

PCoIP Infrastructure Deployment Guide. TER0903005 Issue 1

PCoIP Infrastructure Deployment Guide. TER0903005 Issue 1 PCoIP Infrastructure Deployment Guide TER0903005 Issue 1 2 Teradici Corporation #101-4621 Canada Way, Burnaby, BC V5G 4X8 Canada p +1 604 451 5800 f +1 604 451 5818 www.teradici.com The information contained

More information

NFS File Sharing. Peter Lo. CP582 Peter Lo 2003 1

NFS File Sharing. Peter Lo. CP582 Peter Lo 2003 1 NFS File Sharing Peter Lo CP582 Peter Lo 2003 1 NFS File Sharing Summary Distinguish between: File transfer Entire file is copied to new location FTP Copy command File sharing Multiple users can access

More information

ACHIEVE THIRD PARTY MANAGEMENT (3PL)

ACHIEVE THIRD PARTY MANAGEMENT (3PL) ACHIEVE THIRD PARTY MANAGEMENT (3PL) USER MANUAL Version 6.5 PRESENTED BY ACHIEVE IT SOLUTIONS Copyright 2012-2016 by Achieve IT Solutions These materials are subject to change without notice. These materials

More information

The easy way! Mark Maszak. Jane Lawrence Program Manager Microsoft. Microsoft

The easy way! Mark Maszak. Jane Lawrence Program Manager Microsoft. Microsoft Windows Logo for USB The easy way! Jane Lawrence Program Manager Microsoft Mark Maszak Test Engineer Microsoft Agenda WLK & USB 3.0 Requirements Overview Design Guidelines System: Companion controllers

More information

NB3H5150 I2C Programming Guide. I2C/SMBus Custom Configuration Application Note

NB3H5150 I2C Programming Guide. I2C/SMBus Custom Configuration Application Note NB3H550 I2C Programming Guide I2C/SMBus Custom Configuration Application Note 3/4/206 Table of Contents Introduction... 3 Overview Process of Configuring NB3H550 via I2C/SMBus... 3 Standard I2C Communication

More information

How To Use A Water Quality Monitor (Wqmsw)

How To Use A Water Quality Monitor (Wqmsw) Water Quality Monitor WQM Host Software User s Guide The user s guide is an evolving document. If you find sections that are unclear, or missing information, please let us know. Please check our website

More information

Windows NT File System. Outline. Hardware Basics. Ausgewählte Betriebssysteme Institut Betriebssysteme Fakultät Informatik

Windows NT File System. Outline. Hardware Basics. Ausgewählte Betriebssysteme Institut Betriebssysteme Fakultät Informatik Windows Ausgewählte Betriebssysteme Institut Betriebssysteme Fakultät Informatik Outline NTFS File System Formats File System Driver Architecture Advanced Features NTFS Driver On-Disk Structure (MFT,...)

More information

Outline. Windows NT File System. Hardware Basics. Win2K File System Formats. NTFS Cluster Sizes NTFS

Outline. Windows NT File System. Hardware Basics. Win2K File System Formats. NTFS Cluster Sizes NTFS Windows Ausgewählte Betriebssysteme Institut Betriebssysteme Fakultät Informatik 2 Hardware Basics Win2K File System Formats Sector: addressable block on storage medium usually 512 bytes (x86 disks) Cluster:

More information

ForeScout CounterACT. Device Host and Detection Methods. Technology Brief

ForeScout CounterACT. Device Host and Detection Methods. Technology Brief ForeScout CounterACT Device Host and Detection Methods Technology Brief Contents Introduction... 3 The ForeScout Approach... 3 Discovery Methodologies... 4 Passive Monitoring... 4 Passive Authentication...

More information