Top and Bottom Spray Fluid Bed Granulation Process

Size: px
Start display at page:

Download "Top and Bottom Spray Fluid Bed Granulation Process"

Transcription

1 Top and Bottom Spray Fluid Bed Granulation Process Use of Lasentec FBRM In-Process Particle Sizing PAT Technique to Study Top and Bottom Spray Fluid Bed Granulation Process Presented November 10, 2005 American Association of Pharmaceutical Scientists (AAPS) Nashville, Tennessee B. Smith, METTLER TOLEDO, K. Walter, Niro Pharma Systems, GEA E. Dycus, METTLER TOLEDO M. Hubert, METTLER TOLEDO A. Birkmire, Niro Pharma Systems, GEA Purpose Granulation of fine powders can be performed in a fluid bed processor by spraying solvent or a solvent/binder solution onto a fluidized powder bed (top spray granulation) or by concurrently spraying solvent or a solvent/binder solution into a segregated dilute phase powder stream (bottom spray or "GEA Precision Granulation "). As the powder characteristics change, the process variables must be adjusted to account for changes in the product particle size, bulk density, and flow characteristics. Using Focused Beam Reflectance Measurement (FBRM ), the chord length distribution (CLD) of particles in a fluid bed processor can be precisely measured in real time without sampling or extracting product. The CLD measurement is a function of particle size, particle shape, and particle population. Obtaining this Process Analytical Technology (PAT) measurement in real time allows for continuous adjustment of process variables and detection of processing problems, and can be part of a process where product is suited for real-time release. Influences of spray rates, airflow rates, and filter cleaning can be quantified and optimized to improve product quality and yield. Combining this measurement with real-time microscopy, Particle Vision and Measurement (PVM ) allows real-time, in-line verification of the chord length distribution measurement. Methods A matrix of top spray and bottom spray fluid bed granulation experiments were performed. Critical parameters included: Liquid/binder spray flow rate Airflow rates Atomization pressure Method of spray addition - top spray versus bottom spray Changing excipient distributions The in-line real-time particle distributions were characterized using in situ PAT, Lasentec FBRM and PVM technology. Lasentec FBRM and PVM were used to ultimately control the real-time particle distribution during the fluidized bed process. Experimental description Probes used in the experiment: FBRM D600L - Focused Beam Reflectance Measurementprovides real-time, in-process measurement of particle dimension, number, and shape. PVM Particle Vision and Measurement (video microscopy)-provides in-process images of particle dimension and shape. Figure 1: Lactose Formulation for All Batches Material Weight (%) Lactose 200M (Pharmatose 200M, DMV) 88 Polyvinyl pyrrolidone (K29/32, ISP) 5 Microcrystalline cellulose (Avicel PH-101, FMC) 5 Crospovidone (polyplasdone XL-10, ISP) 2

2 Figure 2: FBRM and PVM Installation Images-Top Spray Figure 3: Bottom Spray-Precision Granulation Process Figure 4: FBRM Installation Images -Bottom Spray Results In the bottom spray granulation process, liquid binder and water are continuously sprayed during three stages: 135 g/min (spray 1), 145 g/min (spray 2), and 160 g/min (spray 3). Following moisture addition, the bed is dried. Using real-time PAT, one can track the number of fine particles in the range 0-100µm decrease in number over time as the number of coarse particles in the range µm and µm grow over time. The square weighted (volume based) mean eventually reaches a steady state. However, when filter blow back occurs during the third spraying regime, there is an obvious upset of fines seen by the increase in particle counts/second 0-100µm. The particle growth and fines upset were verified by the in-line PVM microscope. Attrition and a corresponding increase in fines was noticed during the drying phase of the granulation.

3 Figure 6 depicts FBRM distributions highlighting the beginning and endpoints of the bottom spray granulation progress. FBRM square weighted volume distributions show the increase in granule dimension from spray one to the end of spray three. Statistics calculated from the FBRM distribution quantify the changes that occurred. Figure 5: Tracking Bottom Spray Precision Fluid Bed Granulation Figure 6: Real-Time FBRM Distributions-Bottom Spray Granulation Statistic Spray 1 Spray 3 End Unweighted Median (1-1000µm) Square Weighted Mean (1-1000µm) Number of chords per second in range (1-300µm) Number of chords per second in range ( µm) Real-time in situ PVM images provide a quick snapshot and a true understanding of how the process is changing in real time. Images can quickly validate the FBRM measurement and provide information on particle size, shape, and population. Figure 7: Real- Time PVM Images

4 Figure 8 shows the effect of atomizing pressure on CLD in bottom spray granulation. Higher atomization pressures produced finer granules. By changing the atomization pressure, one can adjust the droplet size and associated wetting behavior. FBRM distributions taken at the end point of two bottom spray granulation batches quantified a 20µm difference in the square weighted (volume) mean. Spray rates were identical between batches. Figure 8: Effect of Changing Process Variables: Atomization Pressurer Experiment PG PG Spray Rate Low Low Atom. Pressure 0.25 Bar 0.5 Bar Mean Square Weight Microns Figure 9 shows the effect of spray rate on CLD in bottom spray granulation. Keeping atomization pressure constant, one can look at the influence of spray rate on granule growth. As expected, higher spray rate produces coarser granules. The real-time response of inline FBRM can be used to quickly quantify granule growth and breakage kinetics. This can be used to provide feedback control signals to adjust critical control parameters. Figure 9: Effect of Spray Rate on Bottom Spray Granulation Experiment PG PG PG Spray Rate Low Intermediate High Atom. Pressure 0.25 Bar 0.25 Bar 0.25 Bar Mean Square Weight Microns Figure 10 shows the effect of atomizing pressure on CLD in top spray granulation. Higher atomization pressure produced finer granules. Significant breakage/attrition was observed during drying stage for top spray granulation. Experiment TSG TSG Spray Rate Figure 10: Top Spray Granulation Atom. Pressure Square Weighted Mean at Spray Endpoint Square Weighted Mean After Drying High 2.5 Bar High 1.5 Bar

5 Figure 11 depicts the endpoint comparison between top and bottom spray granulations via FBRM distributions. Bottom spray granulation had much shorter drying times. This corresponded to less attrition/breakage during drying. Thus, when comparing top to bottom spray granulation, it was easier to target the endpoint particle distribution with the bottom spray process. In this example, when comparing endpoints, bottom spray granulation targeted a larger endpoint mean compared to top spray granulation. Figure 11: Top Spray Versus Bottom Spray Granulation - Targeting Endpoint Distribution Experiment Top Spray Granulation Bottom Spray Granulation Atom. Pressure 1.5 Bar 0.25 Bar Mean Square Weight Microns Conclusions Top spray and bottom spray granulation are dynamically changing processes. Real-time in situ particle characterization with Lasentec FBRM and PVM provides insight into the particle dynamics. This allows the critical process variables to be adjusted to achieve the desired downstream particle characteristics and avoid downstream processing problems. This real-time monitoring could ultimately lead to real-time particle distribution release. Attrition, a key upset during drying, can be minimized using real-time FBRM to detect and avoid the process upsets. Bottom spray granulation also observed much less attrition than top spray granulation during the drying phase of processing. In bottom spray granulation, the spray rate has a much greater effect on granulation than atomizing air pressure in the ranges studied. In-line PAT instruments, such as FBRM and PVM, will allow users to hit target particle distribution specification and reduce or eliminate the number of failed or reworked batches. PAT will reduce analytical costs by in-process testing, improve batch-to-batch consistency, optimize and troubleshoot scale-up, and improve product quality. Figure 12: PVM Images - Top and Bottom Spray Endpoints Bottom spray endpoint

6 North American Headquarters GEA Process Engineering Inc., 9165 Rumsey Road Columbia, MD 21045, US Tel: Fax: Food & Dairy Division Headquarters GEA Process Engineering Inc., 1600 O'Keefe Road Hudson, WI 54016, US Tel: Fax: Top spray endpoint

Particle size measurement of lactose for dry powder inhalers

Particle size measurement of lactose for dry powder inhalers Particle size measurement of lactose for dry powder inhalers MCC Starch Lactose Inhalation Superdisintegrants 1 Introduction The particle size of lactose has been shown to be important for dry powder

More information

GEA Niro Pharmaceutical GMP Spray Drying facility. Spray drying process development and contract manufacturing. engineering for a better world

GEA Niro Pharmaceutical GMP Spray Drying facility. Spray drying process development and contract manufacturing. engineering for a better world GEA Niro Pharmaceutical GMP Spray Drying facility Spray drying process development and contract manufacturing engineering for a better world GEA Process Engineering 2 GEA Niro PSD-4 Chamber cone in clean

More information

Continuous Granulation and Drying

Continuous Granulation and Drying Continuous Granulation and Drying Collette TM Technologies GEA Pharma Systems GEA Pharma Systems supplies advanced technologies for the processing of Active Pharmaceutical Ingredients (API) for the production

More information

Pharmaceutical Quality Systems: US Perspective

Pharmaceutical Quality Systems: US Perspective Pharmaceutical Quality Systems: US Perspective Rick Friedman Associate Director, Office of Manufacturing and Product Quality Center for Drug Evaluation and Research Topics Background: The ICH Q10 Pharmaceutical

More information

STARCH 1500. Application Data

STARCH 1500. Application Data STARCH 1500 Application Data Partially Pregelatinized Maize Starch Starch 1500, Partially Pregelatinized Maize Starch, Used as a Binder Disintegrant in High Shear Wet Granulation Comparison to Povidone

More information

11.I In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07

11.I In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07 In-process control In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07 Here you will find answers to the following questions: What are the in-process control tasks? Where

More information

IN-LINE PARTICLE SIZE MEASUREMENTS FOR CEMENT AND OTHER ABRASIVE PROCESS ENVIRONMENTS

IN-LINE PARTICLE SIZE MEASUREMENTS FOR CEMENT AND OTHER ABRASIVE PROCESS ENVIRONMENTS IN-LINE PARTICLE SIZE MEASUREMENTS FOR CEMENT AND OTHER ABRASIVE PROCESS ENVIRONMENTS 1998 A.P. Malcolmson Malvern, Inc. 10 Southville Road Southborough, MA D. J. Holve Malvern/Insitec, Inc. 2110 Omega

More information

The importance of normalisation when comparing tablet properties

The importance of normalisation when comparing tablet properties The importance of normalisation when comparing tablet properties Tablet quality definition The properties of a tablet, both during manufacturing and in vivo, are determined by the properties of the materials

More information

On-Line Monitoring of A Granulation Process By NIR Spectroscopy

On-Line Monitoring of A Granulation Process By NIR Spectroscopy On-Line Monitoring of A Granulation Process By NIR Spectroscopy MANEL ALCALÀ, 1 MARCELO BLANCO, 1 MANEL BAUTISTA, 1 JOSEP M. GONZÁLEZ 2 1 Departament de Química, Unitat de Química Analítica, Universitat

More information

Evaluating the Effects of Tablet Characteristics on Enteric Tablet Coating in the Novel Supercell TM Coater

Evaluating the Effects of Tablet Characteristics on Enteric Tablet Coating in the Novel Supercell TM Coater Evaluating the Effects of Tablet Characteristics on Enteric Tablet Coating in the Novel Supercell TM Coater 1. Abstract A Birkmire and K Walter Niro Pharma Systems, Columbia, MD USA In the pharmaceutical

More information

PHARMACEUTICAL DEVELOPMENT

PHARMACEUTICAL DEVELOPMENT INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE PHARMACEUTICAL DEVELOPMENT Q8(R2) Current Step

More information

PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE

PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE APPLICATIONS NOTE FOR MEASUREMENTS AT THE ENTRANCE AND EXIT OF A THIRD STAGE SEPARATOR

More information

VALIDATION OF WET AND DRY LASER DIFFRACTION PARTICLE CHARACTERISATION METHODS.

VALIDATION OF WET AND DRY LASER DIFFRACTION PARTICLE CHARACTERISATION METHODS. VALIDATION OF WET AND DRY LASER DIFFRACTION PARTICLE CHARACTERISATION METHODS. Ward-Smith, R.S., Gummery, N. and Rawle, A.F. Malvern Instruments Ltd, Enigma Business Park, Grovewood Road, Malvern, Worcs,

More information

Scanning Electron Microscopy Services for Pharmaceutical Manufacturers

Scanning Electron Microscopy Services for Pharmaceutical Manufacturers Scanning Electron Microscopy Services for Pharmaceutical Manufacturers Author: Gary Brake, Marketing Manager Date: August 1, 2013 Analytical Testing Laboratory www.atl.semtechsolutions.com Scanning Electron

More information

Control Strategy Case Studies

Control Strategy Case Studies Control Strategy Case Studies Vance Novack, GSK Workshop on Implementation of ICH Q8/Q9/Q10 and Other Quality Guidelines Beijing, China, Dec 2008 Control Strategy Case Studies The information and knowledge

More information

Generic Drug Formulations. with. and. Kollidon SR

Generic Drug Formulations. with. and. Kollidon SR Generic Drug Formulations with Kollicoat SR 3 D and Kollidon SR Contents I. Kollicoat SR 3 D Coating 1.1 Theophylline sustained-release pellets 1.2 Theophylline sustained-release pellets (drug-layering

More information

Guide to Inspections of Tablet Manufacturing Facilities including Pre/Post Approval Issues as per USFDA

Guide to Inspections of Tablet Manufacturing Facilities including Pre/Post Approval Issues as per USFDA International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.4, No.1, pp 49-55, Jan-Mar 2012 Guide to Inspections of Tablet Manufacturing Facilities including Pre/Post Approval

More information

A Preliminary Proposal for a Pharmaceutical Engineering Graduate Program

A Preliminary Proposal for a Pharmaceutical Engineering Graduate Program A Preliminary Proposal for a Pharmaceutical Engineering Graduate Program Planning Committee: Prabir Basu Steve Byrn Ken Morris Rex Reklaitis Paul Sojka Venkat Venkatasubramanian Carl Wassgren National

More information

Method Development and Validation for Particle Size and Shape Measurements

Method Development and Validation for Particle Size and Shape Measurements Method Development and Validation for Particle Size and Shape Measurements Ulf Willén Divisional Product Manager Analytical Imaging Systems Malvern Instruments Ltd, Malvern, UK. FDA guidance: when should

More information

Table 1. Pure superdisintegrant tablet formulation. Material % w/w Weight (mg) Superdisintegrant 99 277.2 Stearic acid 1 2.

Table 1. Pure superdisintegrant tablet formulation. Material % w/w Weight (mg) Superdisintegrant 99 277.2 Stearic acid 1 2. PHARMACEUTICAL TECHNOLOGY REPORT Ashland Specialty Ingredients ashland.com PTR-95 Page 1 of 5 Utility of Polyplasdone as a Tablet Binder Quyen Schwing, Marvin Davis, Divya Tewari, Thomas Dürig Ashland

More information

High Performance Dry Binding with CELNY-SSL Super Fine Powder

High Performance Dry Binding with CELNY-SSL Super Fine Powder CELNY TM hydroxypropyl cellulose for nutraceutical & food use NOTE #: APPLICATION: CELNY-SSL-SFP-1 Direct Compression/ ODT Formulation High Performance Dry Binding with CELNY-SSL Super Fine Powder APPLICATION

More information

PRODUCT DEVELOPMENT GUIDE

PRODUCT DEVELOPMENT GUIDE PRODUCT DEVELOPMENT GUIDE PRE-FORMULATION - TABLETS Introduction Guidelines for the development of a ANDA product for the US market, Note: some tests or procedures may be unnecessary. The order of performing

More information

In-Line Filters and Coalescers with Automatic Drains

In-Line Filters and Coalescers with Automatic Drains Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid

More information

LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008

LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008 LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008 PARTICLE CHARACTERISATION IN EXCIPIENTS, DRUG PRODUCTS AND DRUG SUBSTANCES AUTHOR: HILDEGARD BRÜMMER, PhD, CUSTOMER SERVICE MANAGER, SGS LIFE SCIENCE

More information

THE PHARMACEUTICAL INDUSTRY

THE PHARMACEUTICAL INDUSTRY TE PARMACEUTICAL INDUSTRY The pharmaceutical industry in New Zealand takes the active ingredients of drugs (which are imported from overseas) and converts them into a form that can easily be given to a

More information

Directly compressed mini-tablets coated in a solid-wall pan for sustained drug release

Directly compressed mini-tablets coated in a solid-wall pan for sustained drug release Directly compressed mini-tablets coated in a solid-wall pan for sustained drug release March 2012 N. Passerini, B. Albertini, L.Rodriguez Department of Pharmaceutical Sciences, University of Bologna C.

More information

PREPARATION AND EVALUATION OF STARCH PHOSPHATE- A NEW MODIFIED STARCH AS A DISINTEGRANT IN TABLET FORMULATIONS

PREPARATION AND EVALUATION OF STARCH PHOSPHATE- A NEW MODIFIED STARCH AS A DISINTEGRANT IN TABLET FORMULATIONS Int. J. Chem. Sci.: 9(2), 2011, 889-899 Int. J. Chem. Sci.: ISSN 9(1), 0972-768X 2011, 1-11 www.sadgurupublications.com PREPARATIN AND EVALUATIN F STARCH PHSPHATE- A NEW MDIFIED STARCH AS A DISINTEGRANT

More information

5/13/2010. Excipient Fest Porto Rico May 2010. PDF created with pdffactory Pro trial version www.pdffactory.com. Location

5/13/2010. Excipient Fest Porto Rico May 2010. PDF created with pdffactory Pro trial version www.pdffactory.com. Location Excipient Fest Porto Rico May 2010 MEGGLE Excipients & Technology, Wasserburg Germany Dr. Franz Karl Penz Location Meggle headquarters, Wasserburg Germany 5/5/2010 ExcipientFest Puerto Rico 2 1 123 Years

More information

POWDER PROPERTIES LABORATORY

POWDER PROPERTIES LABORATORY Ground Rules POWDER PROPERTIES LABORATORY You will work as a team of no more than 6 students. At the end of this laboratory session each team will turn in a single report. The report will be reviewed,

More information

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY www.irjponline.com ISSN 2230 8407 Review Article

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY www.irjponline.com ISSN 2230 8407 Review Article INTERNATIONAL RESEARCH JOURNAL OF PHARMACY www.irjponline.com ISSN 2230 8407 Review Article INDUSTRIAL PROCESS VALIDATION OF TABLET DOSAGE FORM: AN OVERVIEW Gupta Surbhi 1 *, Saini Seema 1, Singh Gurpreet

More information

Sample preparation for X-ray fluorescence analysis

Sample preparation for X-ray fluorescence analysis Technical articles Sample preparation for X-ray fluorescence analysis III. Pressed and loose powder methods Gakuto Takahashi* 1. Introduction There are two main sample preparation techniques for measurement

More information

Multivariate Tools for Modern Pharmaceutical Control FDA Perspective

Multivariate Tools for Modern Pharmaceutical Control FDA Perspective Multivariate Tools for Modern Pharmaceutical Control FDA Perspective IFPAC Annual Meeting 22 January 2013 Christine M. V. Moore, Ph.D. Acting Director ONDQA/CDER/FDA Outline Introduction to Multivariate

More information

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry BY GHULAM A. SHABIR Introduction Methods Validation: Establishing documented evidence that provides a high

More information

Numerical analysis of size reduction of municipal solid waste particles on the traveling grate of a waste-to-energy combustion chamber

Numerical analysis of size reduction of municipal solid waste particles on the traveling grate of a waste-to-energy combustion chamber Numerical analysis of size reduction of municipal solid waste particles on the traveling grate of a waste-to-energy combustion chamber Masato Nakamura, Marco J. Castaldi, and Nickolas J. Themelis Earth

More information

2Technical Support 3Formulation Development 4Proof of Concept 5 GMP Services 6Advanced Drug Delivery 1EUDRAGIT Products Evonik. Power to create.

2Technical Support 3Formulation Development 4Proof of Concept 5 GMP Services 6Advanced Drug Delivery 1EUDRAGIT Products Evonik. Power to create. GMP Services Solutions for Clinical Sample Manufacturing 1 EUDRAGIT Products 2 Technical Support 3 Formulation Development Proof of Concept 4 5 GMP Services 6 Advanced Drug Delivery Evonik. Power to create.

More information

GEA Niro Pharmaceutical Spray Drying

GEA Niro Pharmaceutical Spray Drying GEA Niro Pharmaceutical Spray Drying Improve drug properties and production with spray drying engineering for a better world GEA Process Engineering Industry-leading technology Spray drying is a technique

More information

COARSE DRY COAL CLEANING

COARSE DRY COAL CLEANING COARSE DRY COAL CLEANING R. Q. Honaker University of Kentucky Department of Mining Engineering Lexington, Kentucky, USA 40506-0107 0107 Workshop on Coal Beneficiation and Utilization of Rejects : Initiatives,

More information

PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS

PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS The end of a fiber optic cable and the inner surface of an optical module lens constitute optical surfaces that should be properly cleaned and maintained

More information

Multivariate Chemometric and Statistic Software Role in Process Analytical Technology

Multivariate Chemometric and Statistic Software Role in Process Analytical Technology Multivariate Chemometric and Statistic Software Role in Process Analytical Technology Camo Software Inc For IFPAC 2007 By Dongsheng Bu and Andrew Chu PAT Definition A system Understand the Process Design

More information

L.B. Bohle invests in processes, research and production

L.B. Bohle invests in processes, research and production 1 2014 INNOVATIV Dear reader, One of the two leading trade fairs in Germany, the Interpack 2014, invites you from May 8th 14th for a visit! We have spared no effort to show you our newest revolutionary

More information

In Situ Spectroscopy. Reaction Analysis and PAT Tools From Research to Manufacturing

In Situ Spectroscopy. Reaction Analysis and PAT Tools From Research to Manufacturing In Situ Spectroscopy Reaction Analysis and PAT Tools From Research to Manufacturing Chemical Synthesis, Engineering and PAT Understanding Reaction Chemistry with ReactIR In Situ Analytical Tools ReactIR

More information

A Course in Particle and Crystallization Technology

A Course in Particle and Crystallization Technology A Course in Particle and Crystallization Technology Priscilla J. Hill 1 Abstract The traditional chemical engineering curriculum is based on vapor-liquid processes with little discussion of processes involving

More information

Guidance for Industry

Guidance for Industry Guidance for Industry Q2B Validation of Analytical Procedures: Methodology November 1996 ICH Guidance for Industry Q2B Validation of Analytical Procedures: Methodology Additional copies are available from:

More information

ISO 21501 A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners

ISO 21501 A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners ISO 21501 A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners Tony Harrison and Bob Latimer ISO 21501- A Standard Methodology to Optical Particle Counter

More information

Guidance for Industry

Guidance for Industry Guidance for Industry Q8, Q9, and Q10 Questions and Answers(R4) U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics

More information

GENERAL GUIDANCE FOR INSPECTORS ON HOLD-TIME STUDIES

GENERAL GUIDANCE FOR INSPECTORS ON HOLD-TIME STUDIES February 2013 RESTRICTED GENERAL GUIDANCE FOR INSPECTORS ON HOLD-TIME STUDIES DRAFT FOR COMMENT Should you have any comments on the attached text, please send these to Dr Sabine Kopp, Manager, Medicines

More information

STABILITY TESTING OF ACTIVE SUBSTANCES AND PHARMACEUTICAL PRODUCTS

STABILITY TESTING OF ACTIVE SUBSTANCES AND PHARMACEUTICAL PRODUCTS RESTRICTED STABILITY TESTING OF ACTIVE SUBSTANCES AND PHARMACEUTICAL PRODUCTS Discussions are currently ongoing with the WHO Eastern Mediterranean Region towards a synergistic approach in developing a

More information

QbD Understanding How Excipient Properties Influence Solid Oral Dosage Form Performance

QbD Understanding How Excipient Properties Influence Solid Oral Dosage Form Performance QbD Understanding How Excipient Properties Influence Solid Oral Dosage Form Performance Dr Amina Faham (Dow), Dr Liz Meehan (AstraZeneca) ExcipientFest, Amsterdam NL June 24, 2014 What do you understand

More information

TABLET REFORMULATION CASE STUDY. Executive Summary

TABLET REFORMULATION CASE STUDY. Executive Summary TABLET REFORMULATION Executive Summary A large European pharmaceutical company contracted Aptuit to reformulate a tablet with existing dosage strengths of 25 mg and 50 mg. The client required smaller strengths

More information

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1) INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY

More information

Like-For-Like Changes: Is Validation Testing Needed? Validation Case Study #7

Like-For-Like Changes: Is Validation Testing Needed? Validation Case Study #7 Paul L. Pluta] Like-For-Like Changes: Is Validation Testing Needed? Validation Case Study #7 Paul L. Pluta Validation Case Studies discusses validation situations useful to practitioners in validation

More information

High Performance Dry Binding with HPC-SSL Super Fine Powder

High Performance Dry Binding with HPC-SSL Super Fine Powder NOTE #: Application: DC-ODT-2 Direct Compression/ ODT Formulation High Performance Dry Binding with HPC-SSL Super Fine Powder Application note Introduction (Super Fine Powder), a highly compressible grade

More information

CHAPTER 2 EXPERIMENTAL. g/mol, Sigma-Aldrich, Germany. 2.1.2 Magnesium acetate tetrahydrate (C 4 H 6 MgO. 4 4H 2 O), assay 99.0%,

CHAPTER 2 EXPERIMENTAL. g/mol, Sigma-Aldrich, Germany. 2.1.2 Magnesium acetate tetrahydrate (C 4 H 6 MgO. 4 4H 2 O), assay 99.0%, CHAPTER 2 EXPERIMENTAL 2.1 Chemicals and Equipments 2.1.1 Zinc naphthenate (2(C 11 H 7 O 2 ). Zn), assay

More information

Design of Experiments for Analytical Method Development and Validation

Design of Experiments for Analytical Method Development and Validation Design of Experiments for Analytical Method Development and Validation Thomas A. Little Ph.D. 2/12/2014 President Thomas A. Little Consulting 12401 N Wildflower Lane Highland, UT 84003 1-925-285-1847 [email protected]

More information

Powder Injection Moulding (PIM) of Dissimilar Materials and Complex Internal Features

Powder Injection Moulding (PIM) of Dissimilar Materials and Complex Internal Features Powder Injection Moulding (PIM) of Dissimilar Materials and Complex Internal Features Li Tao, Scientist II Metal&Ceramic Team, Forming Technology Group, (SIMTech) Tel: 67938968 Email: [email protected]

More information

NIR Chemical Imaging as a Process Analytical Tool

NIR Chemical Imaging as a Process Analytical Tool NIR Chemical Imaging as a Process Analytical Tool NIR chemical imaging greatly extends the capability of NIR spectroscopy, and is the only PAT-applicable blend monitoring technique that gives both statistical

More information

Redefining Spray Technology

Redefining Spray Technology Redefining Spray Technology Macrospray Single-Point Nozzles Macrospray Spider Nozzles Macrospray nozzle technology Improved performance, lower cost Macrospray nozzle technology from Parker Hannifin s Gas

More information

Durapore. High Throughput Flow Rates. Durapore 0.2 µm hydrophilic

Durapore. High Throughput Flow Rates. Durapore 0.2 µm hydrophilic  Durapore CBR 0.2 µm Bioburden Reduction Filters Lenntech Tel. +31-15-261.09.00 Fax. +31-15-261.62.89 DAT A SHEET For fine filtration of deionized water, in vitro diagnostics, oral suspensions, bulk pharmaceutical

More information

Wet Granulation: End-Point Determination and Scale-Up

Wet Granulation: End-Point Determination and Scale-Up Wet Granulation: End-Point Determination and Scale-Up By Michael Levin, Ph. D. Metropolitan Computing Corporation East Hanover, New Jersey, USA Keywords: wet granulation, end-point determination, dimensional

More information

Guideline on Process Validation

Guideline on Process Validation 1 2 3 4 29 March 2012 EMA/CHMP/CVMP/QWP/70278/2012-Rev1 Committee for Medicinal Products for Human Use (CHMP) Committee for Medicinal Products for Veterinary Use (CVMP) 5 6 Draft Draft Agreed by CHMP /

More information

INDEX 03010-1 DESCRIPTION 2 03010-2 MATERIALS 2 03010-3 APPROVAL OF SUBBASE COURSE 3 03010-4 CONSTRUCTION 4 03010-5 MEASUREMENT 6 03010-6 PAYMENT 6

INDEX 03010-1 DESCRIPTION 2 03010-2 MATERIALS 2 03010-3 APPROVAL OF SUBBASE COURSE 3 03010-4 CONSTRUCTION 4 03010-5 MEASUREMENT 6 03010-6 PAYMENT 6 03010_Dec22_2009.pdf Page 1 of 5 INDEX Page 03010-1 DESCRIPTION 2 03010-2 MATERIALS 2 03010-3 APPROVAL OF SUBBASE COURSE 3 03010-4 CONSTRUCTION 4 03010-5 MEASUREMENT 6 03010-6 PAYMENT 6 03010_Dec22_2009.pdf

More information

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS FILTRATION SOLUTIONS Pharmaceutical Manufacturing filtration specialists Delivering quality filtration products As one of Europe s leading manufacturers of process filters, Amazon Filters is able to offer

More information

Atomic Force Microscopy Observation and Characterization of a CD Stamper, Lycopodium Spores, and Step-Height Standard Diffraction Grating

Atomic Force Microscopy Observation and Characterization of a CD Stamper, Lycopodium Spores, and Step-Height Standard Diffraction Grating Atomic Force Microscopy Observation and Characterization of a CD Stamper, Lycopodium Spores, and Step-Height Standard Diffraction Grating Michael McMearty and Frit Miot Special Thanks to Brendan Cross

More information

Process Systems Engineering in Pharmaceutical Development & Manufacture

Process Systems Engineering in Pharmaceutical Development & Manufacture Process Systems Engineering in Pharmaceutical Development & Manufacture G.V. Rex Reklaitis School of Chemical Engineering Purdue University In Sympathy with Tom Edgar s 65 th Birthday NSF ERC FOR STRUCTURED

More information

Modeling and Simulation of Complex Multiphase Flows in the Pharmaceutical Industry

Modeling and Simulation of Complex Multiphase Flows in the Pharmaceutical Industry SIMNET Days 2010 Februar 10, 2010 Modeling and Simulation of Complex Multiphase Flows in the Pharmaceutical Industry D. Suzzi a, G. Toschkoff a, S. Radl a,b, Th. Hörmann a, M. Schaffer a, D. Machold a,

More information

Continuous manufacturing moving towards real-time release. Creating innovations for the pharmaceutical industry. siemens.

Continuous manufacturing moving towards real-time release. Creating innovations for the pharmaceutical industry. siemens. Continuous manufacturing moving towards real-time release Creating innovations for the pharmaceutical industry siemens.com/pharma Strategic partnership Creative ideas and industry expertise A move to continuous

More information

Development of Metal Injection Molding Process for Aircraft Engine Part Production

Development of Metal Injection Molding Process for Aircraft Engine Part Production Development of Metal Injection Molding Process for Aircraft Engine Part Production IKEDA Shuji : Manager, Engine Technology Department, Research & Engineering Division, Aero-Engine & Space Operations SATOH

More information

Manufacturing Quality Concrete Products

Manufacturing Quality Concrete Products CEMEX USA - Technical Bulletin 8.0 Manufacturing Quality Concrete Products Establishing or Upgrading a Quality Program Overview The following guidelines were developed for MCP (manufactured concrete products)

More information

Research needs in pharmaceutical excipients: implications of a global supply chain

Research needs in pharmaceutical excipients: implications of a global supply chain Research needs in pharmaceutical excipients: implications of a global supply chain FY 2015 GDUFA Regulatory Science Initiatives Part 15 Public Meeting June 5, 2015 Silver Spring, MD Stephen W. Hoag, Ph.D.

More information

CLASSIFICATION OF CLEANROOMS

CLASSIFICATION OF CLEANROOMS CLASSIFICATION OF CLEANROOMS Cleanrooms are classified by the cleanliness of their air. The method most easily understood and most universally applied is the one suggested in the earlier versions (A to

More information

Process Validation Protocol (Reference: SOP )

Process Validation Protocol (Reference: SOP ) Project Name Equipment Manufacturer Process Line/Location Project Number Serial Number Model Number Protocol number [Enter Product Title, Number & Strength] MULTI VITAMIN TABLETS PRODUCT CODE: Name: Position:

More information

Asbestos Analysis of Soil and Rock Ed Cahill EMSL Analytical Inc.

Asbestos Analysis of Soil and Rock Ed Cahill EMSL Analytical Inc. Asbestos Analysis of Soil and Rock Ed Cahill EMSL Analytical Inc. 845-469-8671 [email protected] 1 Why Look for Asbestos in Soil/Rock? Asbestos Contamination Sloppy or improper Asbestos Removal jobs can

More information

- KOBAYASHI ZEIN DP -

- KOBAYASHI ZEIN DP - Zein is a major component of corn proteins, called a prolamine soluble in aqueous ethanol. Zein is extracted from gluten meal separated under corn starch production. The acquisition of deodorized and decolourised

More information

Quality by Design Approaches to Analytical Methods -- FDA Perspective. Yubing Tang, Ph.D. FDA/CDER/ONDQA AAPS, Washington DC October 25, 2011

Quality by Design Approaches to Analytical Methods -- FDA Perspective. Yubing Tang, Ph.D. FDA/CDER/ONDQA AAPS, Washington DC October 25, 2011 Quality by Design Approaches to Analytical Methods -- FDA Perspective Yubing Tang, Ph.D. FDA/CDER/ONDQA AAPS, Washington DC October 25, 2011 1 Outline What is Quality by Design (QbD) Role of Analytical

More information

C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to

C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to C 5 chemical development contract research custom synthesis cgmp API manufacturing commercial production Welcome to ChemCon Company profile Company profile ChemCon offers outstanding chemical services

More information

Biomanufacturing Vision for the Future

Biomanufacturing Vision for the Future Biomanufacturing Vision for the Future Shou-Bai Chao, Ph.D. Senior Vice President Global Manufacturing and Technical Operations MedImmune (a Div of AstraZeneca) NIPTE/FDA Research Conference Future of

More information

Solid dosage forms testing: Disintegration test and tablet friability and hardness

Solid dosage forms testing: Disintegration test and tablet friability and hardness Specialized Laboratory for Drug production (N111049) Instructions Solid dosage forms testing: Disintegration test and tablet friability and hardness Tutor: Ing. Jiří Petrů Study program: Drug synthesis

More information

ABB Group March 1, 2010 Slide 1

ABB Group March 1, 2010 Slide 1 Tracy Dye P.E., IFPAC NeSSI Sessions, Winter 2010 OPC Unified Architecture (UA) Analyzer Device Integration (ADI) and the Potential Application to NeSSI Systems March 1, 2010 Slide 1 Introduction OPC 1995

More information

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

GRADATION OF AGGREGATE FOR CONCRETE BLOCK GRADATION OF AGGREGATE FOR CONCRETE BLOCK Although numerous papers have been written concerning the proper gradation for concrete mixes, they have generally dealt with plastic mixes, and very little published

More information

Multi- and Megavariate Data Analysis

Multi- and Megavariate Data Analysis Multi- and Megavariate Data Analysis Basic Principles and Applications Third revised edition L. Eriksson, T. Byrne, E. Johansson, J. Trygg and C. Vikström Chapter 18 Process Analytical Technology (PAT)

More information

DOWEX Resins as Organic Solvent Desiccants

DOWEX Resins as Organic Solvent Desiccants Product Information DOWEX Resins as Organic Solvent Desiccants DOWEX* ion exchange resins can be used as desiccants for organic solvents, after having been dried to a low moisture level, in a manner similar

More information

In this column installment, we present results of tablet. Raman Microscopy for Detecting Counterfeit Drugs A Study of the Tablets Versus the Packaging

In this column installment, we present results of tablet. Raman Microscopy for Detecting Counterfeit Drugs A Study of the Tablets Versus the Packaging Electronically reprinted from June 214 Molecular Spectroscopy Workbench Raman Microscopy for Detecting Counterfeit Drugs A Study of the Tablets Versus the Packaging With the increasing proliferation of

More information

Use of OpenFoam in a CFD analysis of a finger type slug catcher. Dynaflow Conference 2011 January 13 2011, Rotterdam, the Netherlands

Use of OpenFoam in a CFD analysis of a finger type slug catcher. Dynaflow Conference 2011 January 13 2011, Rotterdam, the Netherlands Use of OpenFoam in a CFD analysis of a finger type slug catcher Dynaflow Conference 2011 January 13 2011, Rotterdam, the Netherlands Agenda Project background Analytical analysis of two-phase flow regimes

More information

B i o s o l u t i o n s

B i o s o l u t i o n s B i o s o l u t i o n s Implementation of pharmatracker TM : A case study Prepared by Ocimum Biosolutions Ocimumbio Solutions August 2006 All rights reserved. 2 B i o s o l u t i o n s an ISO 9001:2000

More information

Comparison of Analytical Methods for Evaluating Mold in Carpet Dust

Comparison of Analytical Methods for Evaluating Mold in Carpet Dust Comparison of Analytical Methods for Evaluating Mold in Carpet Dust R. Rottersman, MS, CIH & G. Crawford, CIH Boelter & Yates, Inc. Park Ridge, IL P. Fallah, PhD EMLab San Diego, CA Carpet & Indoor Mold

More information

1. Introduction 1. INTRODUCTION

1. Introduction 1. INTRODUCTION 1. INTRODUCTION 1. Introduction Nowadays, numerical simulation plays one of the key roles in the area of solids process engineering. It is applied to describe, to analyze and to predict process behavior

More information

INTRODUCING THE NEW. Xcelodose S. New Powder Micro-dosing System. Even Faster Time to First in Man

INTRODUCING THE NEW. Xcelodose S. New Powder Micro-dosing System. Even Faster Time to First in Man INTRODUCING THE NEW Xcelodose S New Powder Micro-dosing System Even Faster Time to First in Man Xcelodose S Benefits Even Faster Time to First in Man with precision, speed and accuracy Fills with precision

More information

International Journal of Applied Pharmaceutics Vol 2, Issue 3, 2010

International Journal of Applied Pharmaceutics Vol 2, Issue 3, 2010 International Journal of Applied Pharmaceutics Vol 2, Issue 3, 2010 Review Article COPROCESSING OF EXCIPIENTS: A REVIEW ON EXCIPIENT DEVELOPMENT FOR IMPROVED TABLETTING PERFORMANCE MINAKSHI MARWAHA* 1,

More information

Algae Harvesting, Dewatering and Extraction

Algae Harvesting, Dewatering and Extraction Algae Harvesting, Dewatering and Extraction Safe Harbor Statement Matters discussed in this presentation contain forward-looking statements within the meaning of the Private Securities Litigation Reform

More information

Elektra. Elektra. training. manual. manual. Coffee Grinder. Coffee Grinder SHARING THE PASSION

Elektra. Elektra. training. manual. manual. Coffee Grinder. Coffee Grinder SHARING THE PASSION Elektra manual Coffee Grinder I T A L I A N E S P R E S S O C O F F E E M A C H I N E S AD: Holbein & Partners - Edition January 2006 Elektra training SHARING THE PASSION manual I T A L I A N E S P R E

More information

CARING FOR WATER DAMAGED PAINTINGS

CARING FOR WATER DAMAGED PAINTINGS CARING FOR WATER DAMAGED PAINTINGS A GUIDE FOR ARTISTS Rustin Levenson Art Conservation As the creators of works of art, artists have the discretion to revise or rework their pieces in their possession.

More information

PROPOSAL FOR REVISION OF THE SUPPLEMENTARY GUIDELINES ON GOOD MANUFACTURING PRACTICES: VALIDATION, APPENDIX 7: NON-STERILE PROCESS VALIDATION

PROPOSAL FOR REVISION OF THE SUPPLEMENTARY GUIDELINES ON GOOD MANUFACTURING PRACTICES: VALIDATION, APPENDIX 7: NON-STERILE PROCESS VALIDATION April 2013 RESTRICTED 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 PROPOSAL FOR REVISION OF THE SUPPLEMENTARY GUIDELINES ON GOOD MANUFACTURING PRACTICES:

More information

METHOD OF TEST FOR UNIT WEIGHT OF FRESH CONCRETE

METHOD OF TEST FOR UNIT WEIGHT OF FRESH CONCRETE STATE OF CALIFORNIA BUSINESS, TRANSPORTATION AND HOUSING AGENCY DEPARTMENT OF TRANSPORTATION DIVISION OF ENGINEERING SERVICES Transportation Laboratory 5900 Folsom Blvd. Sacramento, California 95819-4612

More information

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD INGOLD Leading Process Analytics Retractable Housings InTrac Retractable Sensor Housings for Harsh Applications Wide Range of Options Intelligent Sensor Locking System Highly Efficient Sensor Cleaning

More information

sugar sugar products for your sweet success

sugar sugar products for your sweet success sugar sugar products for your sweet success quality, supply, delivery Many of the world s largest and best-known food manufacturers rely on ADM for hundreds of essential food ingredients. Our renewably-sourced

More information

Dry Grinding of Technical Ceramics into the Submicron Range

Dry Grinding of Technical Ceramics into the Submicron Range Dry Grinding of Technical Ceramics into the Submicron Range S. Miranda, E. Yilmaz Micronization is the miniatur ization of particles by jet milling with compressed air or other gas to a range of 2 200

More information

Optimizing Tank Cleaning Operations

Optimizing Tank Cleaning Operations Optimizing Tank Cleaning Operations Choosing the best way to thoroughly clean your tanks while minimizing use of costly chemicals, water and manual labor can be challenging. There are several things you

More information

How To Remove A Large Particle From A Large Tank

How To Remove A Large Particle From A Large Tank Delta Series Premium Filters www.numatics.com Table of Contents Delta Series Features and Benefits 3 Science of Coalescing Filtration 4 Water Separator 5 How to Order - Water Separator 6 Pressure and Temperature

More information