NobelProcera EXPERIENCE THE NEW WORLD OF CAD/CAM DENTISTRY
|
|
|
- Ira Hampton
- 10 years ago
- Views:
Transcription
1 EXPERIENCE THE NEW WORLD OF CAD/CAM DENTISTRY
2 2 At a glance. Highlights All indications On natural teeth On implants and abutments Computer-assisted design and -aided manufacturing CAD/CAM accuracy Best precision of fit production accuracy < 10 μm internal fit < 50 μm High material biocompatibility and homogeneity Proven and sound clinical outcomes Materials Zirconia (ZrO 2 ) 1120 MPa average flexural strength Alumina (Al 2 O 3 ) MPa flexural strength Titanium 345 MPa and 860 MPa tensile strength Colors Zirconia white, light, medium, intense Alumina translucent, white Versatility Zirconia crown copings cement- and screw-retained bridges, up to 14 units abutments Alumina crown copings and laminates cement-retained bridges, up to 4 units Titanium screw-retained bridges, up to 14 units abutments
3 3 NobelProcera TM experience the new world of CAD/CAM dentistry. Modern-day dentistry was revolutionized in 1983 by the development of a system that applied standardized industrial manufacturing processes to the production of individualized dental prosthetics. This system, named Procera, created a paradigm shift in dentistry by producing high quality, individually fitting, biocompatible prosthetics for patients. Since its introduction, Procera has led the computeraided design (CAD) and computer-aided manufacturing (CAM) dental industry. Now, Nobel Biocare introduces the new world of CAD /CAM dentistry that will set new industry standards for materials, products, services and support welcome to NobelProcera! Comprehensive CAD/CAM dental prosthetics for all indications Excellent materials and production for best precision of fit and safety Cutting-edge 3D software and optical scanner offer optimum versatility Exclusive 5-year product warranty against material breakage or defects State-of-the-art production centers for high quality Global expert network of 4,000 dental labs and professionals Backed by more than 15 years of clinical experience and research NobelProcera offers dental professionals a highly comprehensive portfolio of individualized dental prosthetics produced from materials of excellent homogeneity. Prosthetics are designed using cutting-edge scanning and software technologies, then manufactured at state-of-the-art production facilities employing strategies which maximize quality, safety and precision of fit. Ultimately, NobelProcera prosthetics provide long-term clinical performance and patient satisfaction 1 3, which is supported by a 5 -year product warranty.
4 4 1. Dentist 2. Laboratory 3. Nobel Biocare 4. Laboratory 5. Dentist The restorative clinician begins the NobelProcera process by following conventional crown and bridge preparation and impression routines for the proposed restoration. The dental laboratory scans the physical impression with a NobelProcera scanner and, using cutting-edge CAD software, designs an accurate digital restoration. When completed, the lab sends the completed design /data package via the Internet to a NobelProcera production facility. Using advanced milling strategies and high-end finishing techniques, the NobelProcera production facility produces a precision framework. Following a rigorous quality control check, the framework is shipped back to the dental laboratory. The framework received by the dental laboratory is ready to use and therefore does not require extensive finishing /polishing before veneering layers are applied. Once the restoration matches the patient s adjacent teeth, in color and shape, the technician sends the finished product to the restorative clinician. Depending on the type of restoration, the restorative clinician will cement or screw the received finished product in the prepared patient restoration site. Centralized industrial manufacturing process.
5 5 NobelProcera TM leading CAD /CAM dentistry. CSR % on teeth cumulative Survival Rates after 5 years in function With NobelProcera, dental professionals gain access to a state-of-the-art world of CAD /CAM dentistry, including modern production facilities, for all types of restorations and treatment options. Latest production technology The new world of NobelProcera represents the next generation for prosthetics in terms of precision of fit, material homogeneity and mechanical stability compared to conventional casting techniques. With worldwide modern production facilities and innovation centers in Stockholm, Mahwah, Tokyo, Quebec and Mechelen, Nobel Biocare streamlined industrialized NobelProcera fabrication processes beginning with highly homogeneous raw materials. After sintering and milling, products demonstrate exceptional internal and marginal precision of fit, 4, 5 mechanical stability and biocompatibility, 6 8 and provide years of safe and reliable service. 1, 9 Prosthetics for all indications NobelProcera produces ready-to-use abutments, copings and frameworks with high esthetics and biocompatibility, based on CAD information received from partnering NobelProcera dental laboratories. Cutting-edge technology Nobel Biocare dedicates itself to the constant refinement of NobelProcera. This includes developing new materials, enhancing CAD /CAM software, production and scanning technologies. The latest NobelProcera innovation is a completely new optical impression scanner and cutting-edge software package that will streamline and improve the design / production workflow of NobelProcera partners. Global network of dental experts All NobelProcera partners benefit from the support of the largest established digital dentistry network in the world, comprised of three global production facilities and 4,000 laboratories in 75 countries. Proven safe and effective Fifteen years of cumulative clinical experience and research have demonstrated the long-term success and efficacy of NobelProcera individualized solutions, which are often superior to other dental ceramics systems and conventional crown and bridge restorations. 93 NobelProcera Empress * InCeram * PFM * Empress is a registered trademark of Ivoclar Vivadent, InCeram is a registered trademark of Vita Zahnfabrik. Pjetursson BE, et al. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns. Clin Oral Implants Res 2007; 18 Suppl 3: years of clinical experience with Procera Alumina. A Review. Haag P, Andersson M, Vult von Steyern P, Odén A. Appl Osseointegrat Res 2004;4:7-12. A review containing description of clinical studies and in vitro studies performed on clinical criteria. NobelProcera offers dental professionals the full range of prosthetics for both natural-tooth and implant-retained restorations. The NobelProcera prosthetics portfolio is the largest and most versatile of all currently available CAD /CAM systems.
6 6 Crown for natural-tooth or implant-retained restorations. Industrial fabrication For high product quality and long-term success. Broad prosthetic versatility Natural-tooth or implant-retained prosthetics for all patient clinical and esthetic needs. Optimal veneering thickness Prosthetics are designed so veneering layer thickness is uniform to prevent chipping. Conventional crown and bridge techniques Tooth preparation and cementation routines are similar to those used for conventional cast restorations. CAD /CAM Precision of fit Increases efficiency by eliminating the need for time-consuming adjustments prior to placement.
7 7 NobelProcera TM preferred solutions for all indications. 48-month data of a retrospective clinical evaluation of 86 Procera AllCeram crowns Surface and color Excellent 82 Acceptable 3 Not acceptable Dental clinicians benefit from a comprehensive range of advantages that NobelProcera brings. These include a highly effective process for handling and production of the prosthetics, a comprehensive range of materials and products for all indications, as well as very high functionality and highly esthetic outcome. Solutions for all patient needs NobelProcera provides customized solutions that satisfy all clinical, esthetic and budgetary requirements of the patient, and delivers highly esthetic and naturallooking results: Crown and bridge frameworks Implant abutments 10 23, 24 Laminates Implant superstructures, such as bars and telescopes Wide selection of materials Prosthetic components are currently produced from three highly biocompatible materials: zirconia, alumina and titanium. Zirconia and alumina are also available in different colors to assist in matching neighboring dentition. Additional materials are currently in development and are scheduled for release during Highly effective restorations NobelProcera precision of fit greatly influences the efficiency of crown and bridge restoration procedures; this efficiency is often expressed in reduced patient chair time, which means more time for more patients and greater profitability. Clinical precision and safety All NobelProcera production steps are closely monitored and calibrated around the clock, everyday. This level of precision guarantees the consistent high quality and safety of every NobelProcera product. In addition to the precision of fit of NobelProcera products, the high biocompatibility of NobelProcera materials 6 8 reduces potential allergic reactions commonly associated with solutions created from non-homogeneous and dissimilar materials. In combination with the customized shapes of the restorations, NobelProcera products support long-term soft tissue stability and produce high esthetic outcomes. Additionally, the TorqTite screws, available for all screw-retained prosthetics, have been specially treated to ensure proper pre-load and reduce the incidence of component loosening. Adopting NobelProcera is easy Preparation and cementation protocols are similar to those used with conventional crown and bridge restorations. However, to ensure the ultimate success of each NobelProcera restoration, Nobel Biocare provides dental clinicians with detailed handling guidelines, developed in collaboration with a number of leading industry experts and universities.* Anatomic form Excellent 85 Acceptable Not acceptable Marginal integrity Excellent 84 Acceptable 1 Not acceptable Clinical evaluation according to California Dental Association (CDA) quality evaluation system. Zarone F, et al. Retrospective clinical evaluation of 86 Procera AllCeram anterior single crowns on natural and implant-supported abutments. Clin Implant Dent Relat Res 2005;7 Suppl 1: * Markus Blatz, University Pennsylvania; Jonathan Ferencz, New York University; Stefan Holst, University Erlangen; Mathias Kern, University Kiel; Hans Geiselhöringer, Dental X Laboratories Munich.
8 8 Bridge Alumina on natural teeth. CAD /CAM manufacturing strategies Produce high product quality and precision of fit, which delivers long-term clinical success and safety. Homogeneous and biocompatible materials Zirconia (four colors) and Alumina (white and translucent). Individual design Individual virtual framework design for better esthetics. Broad clinical applications Single crowns and bridges. Easy to integrate into a practice Tooth preparation and cementation routines are similar to conventional crown and bridge techniques.
9 9 NobelProcera TM on natural teeth. The preservation and restoration of natural teeth with crowns, bridges and laminates is the daily business of dental professionals. For natural teeth, NobelProcera offers a complete range of prosthetics which demonstrates excellence in precision of fit, biocompatibility and esthetics. Reproducible precision of fit NobelProcera optimized milling and sintering strategies consistently producing copings and frameworks that are more precise than those created in conventional casting techniques. 5, 13 Additionally, the purity and homogeneity NobelProcera materials yield 14, 15 products of exceptional strength. All-ceramic biocompatibility NobelProcera natural-tooth restorations are metal-free solutions and highly biocompatible. This means there are neither corrosive phenomena nor potential allergic reactions, commonly associated with the presence of dissimilar metals and alloys in the oral cavity. Individual design for better esthetics All NobelProcera prosthetics are individually designed according to patient specifics, using cutting-edge 3D design software, or by scanning a wax-up. Ceramic solutions on natural teeth deliver excellent esthetics 11, 12 and can effectively mask underlying tooth discoloration. 16 Crowns in Zirconia and Alumina NobelProcera offers crown copings in two materials and two thickness of each: NobelProcera Crown Zirconia (0.4 mm and 0.7 mm) and NobelProcera Crown Alumina (0.4 mm and 0.6 mm). Thickness selection is indication dependent and designed for providing uniform support for the veneering 1, 3, 17 layers. Bridges in Zirconia and Alumina NobelProcera bridges for natural-tooth restorations are customized designed and milled from pre-sintered blanks of zirconia and /or alumina. The material homogeneity of these blanks delivers maximum biomechanical strength and allows for high precision of fit 18 22, which assist in providing optimal soft tissue support and esthetics NobelProcera Bridge Zirconia is available in full arches (up to 14 units), whereas NobelProcera Bridge Alumina is perfectly suited for anterior use, up to 4 units. Both bridges follow conventional cementation techniques. Laminates in Alumina NobelProcera Laminates are 0.25 mm thin, veneers made from alumina that have been designed to cover only the outside of natural teeth. Laminates possess excellent masking capabilities and are applied using simple tooth preparation and bonding 16, 23, 24 techniques. Distortion in μm Mean value in MPa Less distortion with CNC-milled Ti Frameworks x-axis y-axis z-axis 3D Gold (cast-gold frames) CNC titanium frameworks Örtorp A, et al. Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible. Int J Prosthodent 2003; 16 (2): Biaxial flexural strength according to ISO AllCeram* InCeram * Empress * Wagner WC, Chu TM. Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics. J Prosthet Dent Biaxial flexural strength according to ISO 6872 Flexural strength (MPa) NobelProcera DC-Zirkon * Zirconia Sierraalta M, Oden A, Razzoog ME. Material strength of zirconia produced with two methods. J Dent Res 2003;82 (Spec Iss A):abstract # * InCeram is a registered trademark of Vita Zahnfabrik, Empress is a registered trademark of Ivoclar Vivadent, DC-Zirkon is a registered trademark of DCS Dental. AllCeram is a Nobel Biocare trade name for alumina.
10 10 Bridge Zirconia on implants. Competitor compatibility Cemented prosthetics are always compatible with competitor implant systems. Screw-retained prosthetics are compatible with a number of competitor implant systems. Morphologic connector design Guarantees long-term stability and strength along the entire span of the bridge. Automatic cut-back function Ensures a uniform veneering material thickness over the entire prosthetic. Broad clinical applications Single crowns and bridges, up to 14 units. Three biocompatible materials Prosthetics are available in zirconia, alumina and titanium, depending on the clinical and esthetic needs of the situation. Titanium abutment For increased strength when desired. Customized transmucosal profile For adequate soft tissue support and long-term hygiene maintenance. Zirconia abutments For maximum esthetics and biocompatibility. TorqTite abutment screw Specially coated screw for ideal pre-torque and reduced screwloosening. Precision of fit For ideal load transfer.
11 11 NobelProcera TM on implants. One of the most important factors a dental professional must consider is the selection of proper materials. For implant-supported restorations, NobelProcera delivers a full range of highly biocompatible, strong and safe solutions, which also satisfy dental practitioner material requirements. Material strength, biocompatibility and the precision of fit in superstructure components greatly influence long-term 2, 12 clinical success and patient satisfaction. Optimum prosthetic flexibility NobelProcera offers a broad range of prosthetic restorations, for all indications and clinical requirements. These include: screwor cement-retained solutions for single and multiple-unit restorations, at abutment or implant level. NobelProcera Solutions are easy to handle and are designed to meet the patient expectation and need. They provide excellent esthetic outcomes and meet all levels of affordability. To ease the restoration process, abutment-supported cement-retained solutions follow conventional crown and bridge techniques. Supporting soft tissue health Scientific research has shown that implant abutment and superstructure material can affect both the amount and the quality of the surrounding tissues. 6, 7, 25 This research has also shown that ceramic abutments minimize bacterial and plaque adhesion and 6, 26 improve soft tissue health. Compatibility with other systems NobelProcera is also a viable option for clinicians who restore other brands of implants. Restoring with screw-retained solutions NobelProcera is compatible with a variety of other implant brands* (see page 13). Complete range of crowns and bridges For cement-retained solutions on implants, NobelProcera offers a complete portfolio of crowns and bridges for use on NobelProcera abutments. Crowns and bridges are produced from the highly homogenous materials alumina and zirconia, in a number of colors and thicknesses. NobelReplace Tapered Groovy RP Implant and Abutment Zirconia. Scanning electron microscope (SEM) images of abutment/implant interface (precision of fit < 0.5 μm).
12 12 Abutment Zirconia on Nobel Biocare implants. 1 TorqTite screw Specially coated component screw ensures proper pre-load and reduces risk of loosening. 2 Precision of fit Excellent abutment / implant interface provides for ideal load transfer. 3 Customized transmucosal profile Improves soft tissue support and long-term hygiene maintenance Brånemark System Mk III Groovy external hexagonal connection NobelReplace Tapered Groovy Tri-channel (tri-lobe) internal connection NobelActive internal conical connection with hexagonal interlocking
13 13 Abutments in Zirconia and Titanium NobelProcera Abutments are milled from zirconia or titanium. Each NobelProcera Abutment is customized and highly biocompatible 6, 7, 25, delivering high esthetics and maximum long-term tissue stability. NobelProcera Abutments are also cost-effective, because no pre-fabricated abutments need to be stocked. Largest choice in implant bridges NobelProcera Implant Bridges are designable up to 14 units and are milled from a pre-sintered zirconia blank or solid block of titanium. This ensures material homogeneity, as well as eliminates the need for soldering or cementing of components. The high quality material also delivers exceptional biocompatibility and ideal soft tissue interface. Implant bridges in zirconia NobelProcera Implant Bridge Zirconia is a CAD/CAM fabricated implant bridge available in zirconia for restorations up to 14 units. Every NobelProcera Implant Bridge Zirconia is milled from the highest grade zirconia then sintered in a closely monitored and controlled process. Produced frameworks demonstrate exceptional biocompatibility 6, 7 and strength (1120 MPa average flexural strength 28, 29 ) making Implant Bridge Zirconia appropriate for nearly any clinical indication. 20 Implant bridges in titanium Whenever material properties or the clinical situation limit the application of zirconia superstructures, titanium provides an excellent alternative solution. Every NobelProcera Bridge Titanium is milled from a homogenous titanium block for high strength, in a closely monitored and controlled process. Both NobelProcera Bridge Zirconia and NobelProcera Bridge Titanium are easily customizable, using either NobelProcera Software or by scanning a wax-up. This added flexibility reduces time and cost for both dental laboratories and clinicians. Finally, similar to NobelProcera Abutment Titanium, NobelProcera Bridge Titanium is compatible with a variety of other implant brands.* Component screws To increase success of screw-retained solutions, NobelProcera implant restorations are delivered with abutment screws that have been coated with a friction-reducing surface TorqTite. This surface offers optimum pre-loading of the prosthetics and a long-term stable screw joint, which help reduce the incidence of screw loosening. * Abutment Zirconia Straumann Regular Neck 4.8 mm implants. Camlog Implant Systems 3.3, 3.8, 4.3, 5.0, 6.0 mm. Abutment Titanium Straumann Regular Neck 4.8 mm implants. Camlog Implant Systems 3.3, 3.8, 4.3, 5.0, 6.0 mm. Astra Tech Implant System 4.5 ST, 5.0 ST mm. Implant Bridge Zirconia, implant level 3i 3.75, Lifecore Biomedical Restore 3.75, Sterngold Implamed Implant Bridge Titanium, implant level Straumann Regular Neck 4.8 and Wide neck i Lifecore Biomedical Restore Sterngold Implamed Implant Bridge Titanium, abutment level Ankylos Implant System 3.5, 4.5, 5.5, 7.0 mm. Camlog Implant System 3.3, 3.8, 4.3, 5.0, 6.0 mm. Astra Tech Implant System 4.5 ST, 5.0 ST mm. Astra Tech 3.5, 4.0, 4.5, 5.0 ST are trademark products of Astra Tech, Straumann Regular Neck 4.8 is a trademark product of Institute Straumann. 3i 3.75 is a trademarked product of Biomet Group Lifecore Biomedical, Restore 3.75 is a registered product of Lifecore Biomedical, LLC. Sterngold Implamed 3.75 is a registered product of Sterngold Dental, LLC. Astra Tech is a trademark of AstraZeneca Group. Straumann is a registered trademark of Institute Straumann.
14 14 colored zirconia. Full zirconia assortment* in four colors. Innovative coloring technique Ensures consistency in material strength and consistent color throughout the framework. white light medium intense Excellent material homogeneity NobelProcera Zirconia is certified for purity and homogeneity. Excellent flexural strength All colors of zirconia demonstrate exceptional flexural strength and show no degradation in strength compared to white zirconia.** Excellent esthetic results 27 Supported by the coloring of the underlying framework. * NobelActive product assortment currently under development. ** NIOM, Norway.
15 15 NobelProcera TM full zirconia assortment in four colors. Based on the market need for more esthetic options using zirconia copings, NobelProcera offers its full zirconia prosthetic assortment in four colors: white, light, mild and intense from single crown and bridges (up to 14 units) restorations, cemented on natural teeth and screwretained (fixed to removable) on implants*. Improved esthetics Ceramic restoration esthetics depend heavily on the translucency of the veneering materials, but also on the shade or coloring of the underlying framework. 27 This cooperation is similar to that of a natural tooth enamel and its underlying dentin. Having a shaded framework greatly increases the chances of creating naturallooking restorations and matching neighboring dentition, especially in long span implant-retained superstructures. Moreover, the high biocompatibility with reduced bacterial surface adhesion make zirconia an excellent choice for implantretained superstructures in close contact with surrounding soft tissues. 30 Innovative coloring technique In contrast to immersion dyeing, NobelProcera uses an innovative coloring technique that ensures consistent color throughout frameworks, without sacrificing material homogeneity or strength. Additionally, consistent color throughout frameworks eliminates the need for manual shading protocols and the white collar shine-through of implant abutments in cases where soft tissue recedes. Excellent material homogeneity Like all NobelProcera materials, the material homogeneity of NobelProcera colored zirconia remains consistent throughout the framework. Likewise, the flexural strength of colored frameworks demonstrate no statistical difference in flexural strength compared to their white counterparts 28, 29, which adds to the longevity of the prosthetic. * NobelActive product assortment currently under development.
16 16 prosthetic software. Automatic cut-back function For ideal veneering material thickness. Morphologic connector design Assists long-term stability. Intuitive software architecture For easy application. Anatomic tooth library For time-saving design. Automatic setting of finish line Saving technician s time. Visibility tool To review the prosthetic design from every possible angle. optical scanner. Full and future product assortment Scanner support for current and future advancements in materials and solutions. High accuracy and shorter scanning time Only minimal user intervention during scanning. Patented proprietary scanner technology For fast and highly precise data acquisition.
17 17 NobelProcera TM tomorrow s technology, today. NobelProcera adds a new level of efficiency and cost effectiveness through outsourcing and centralizing framework production processes. Outsourcing for profitability First, outsourcing framework production eliminates the investment in different in-house systems, as well as the time and money spent updating, maintaining, and training on these systems. Second, NobelProcera eliminates the need to maintain an extensive assortment of standard products, commonly used in conventional casting techniques. Third, the time previously spent creating in-house frameworks can now be used for processing additional orders leading to extra revenue for the laboratory. NobelProcera production is on-demand and available twenty-four hours a day, with an average three business day product turn-around time. Fourth, NobelProcera production facilities employ optimized milling and finishing routines according to material prerequisites therefore prosthetics received are ready to use and rarely require timeconsuming finishing and polishing. Comprehensive prosthetic portfolio NobelProcera customizes and produces everything from fixed to removable solutions, from single tooth to long span frameworks for meeting clinical and esthetic expectations with excellent precision of fit 5, 13 production accuracy <10 μm and internal fit < 40 μm. 29 Certified raw materials The highly homogeneous raw materials used in the NobelProcera fabrication process demonstrate excellent precision of fit and do not distort during veneering. 5 For added peace of mind, every NobelProcera product is delivered with a certificate of authenticity, verifying the purity of the raw materials. Easy integration of To ensure the ultimate success of each NobelProcera restoration, Nobel Biocare provides dental laboratories with detailed handling guidelines, developed in cooperation with a number of leading industry experts and universities.* * Markus Blatz, University Pennsylvania; Jonathan Ferencz, New York University; Van Thompson, New York University; Stefan Holst, University Erlangen; Mathias Kern, University Kiel; Peter Rammelsberg, University Heidelberg; Hans Geiselhöringer, Dental X Laboratories München. State-of-the-art CAD/CAM NobelProcera is setting new standards with a cutting edge scanner and software package developed by technicians for technicians. Patented optical scanning methods, and ground-breaking intuitive 3D design software version will expand the capabilities of dental clinicians and labs for producing and delivering high-class quality individualized prosthetics. Simultaneously, these new tools will increase efficiency and reduce in-house costs.
18 18 Optical Scanner. Impression scanning capability Increased laboratory efficiency and future model production. Unique conoscopic holography technology Co-linear scanning technology for improved data acquisition efficiency. Intuitive holder design Option for batch scanning of single copings. Open air design For ease of access, set-up and use. Moving object table High speed, stable platform for fast and accurate scanning.
19 19 NobelProcera TM innovative scanner technology. NobelProcera introduces the next advancement in optical scanning technology for CAD /CAM dentistry: a new scanner that uses a unique and patented proprietary scanner technology conoscopic holography for fast and highly precise data acquisition. Conoscopic holography working principle Measured pattern on the director Leading conoscopic holography Conoscopic holography is superior to other optical scanner techniques, such as triangulation, in that the projected and reflected beams travel the same linear pathway to and from the scanned object, respectively (see on the right). This co-linearity allows measurements of steep angles and deep cavities, such as those found in dental impressions. Polarizer Conoscopic crystal Polarizer Innovation that adds clear benefits For each measured point, a large amount of information is retrieved using conoscopic holography; therefore, accuracy of the scans is very high and scanning times are shorter. Object Laser Due to co-linearity scanning, steep slopes up to 85 can be measured, compared with the limited capability of triangulation scanners, 40 to 60. Additionally, using this methodology, basically every material can be scanned only very shiny metal or translucent wax /acrylic objects cannot be scanned. Measured object The set-up and operation of the scanner has also been simplified one set-up per case and only minimal user intervention is required during scanning. This simplification has also resulted in a reduction in the time needed to train users. Transmitted light Reflected light
20 20 Latest software technologies used for. Virtual framework design Eliminates the need for wax / set-ups. Cross section tool Accurately measures CAD framework. Material selection Alumina, Zirconia, Titanium and other materials. Intuitive user-friendly interface Simple icons guide the user through the complete design process. 2D view Good overview of the clinical situation. Visibility editor A simplified preview of the prosthetic design.
21 21 NobelProcera TM cuttingedge prosthetic software. Supporting the expansive capabilities of the state-of-the-art NobelProcera optical scanner is a completely new, user-friendly NobelProcera Software package for 3D designing of prosthetic frameworks. By technicians for technicians This new NobelProcera software version engineered by industry leading dental technicians and 3D software experts simplifies prosthetic design by guiding users through each step of a predictable design workflow. Within the clean and intuitive environment and a click of a button, technicians are able to choose the desired material, define prefabricated retentive elements, and select automated CAD options for customized crowns and bridges, and in the future telescope abutments / crowns and bars. Automatic setting of the finish line: when completing the design, the new software version can automatically determine the appropriate finish line for the prosthetic. This editable finish line automation saves technicians the time of creating one by hand. Morphologic connector design: pontic connectors are easily customizable and viewable. Proper connector design is paramount for creating and veneering a prosthetic that will provide long-term safety for the patient. Visibility tools: simplified buttons change to visual aspect of the design. These tools enable technicians to review the prosthetic design from every possible angle. As well, a 2D editor provides a cross-section of the final prosthetic. The easily navigable interface is embedded with highly advanced CAD dentistry tools, which offer technicians nearly limitless design possibilities, and more flexibility and efficiency. Here are only a few: Anatomic tooth library: base shapes are available so prosthetic designs are not from scratch each time. Base shapes shave considerable time from and maximize the efficiency of the initial design phase. Automatic cut-back function: framework designs are optimized for uniform veneering material thickness. Uniform layering helps reduce potential chipping or cracking of the veneering material under daily patient use.
22 22 Pre-sintering phase of NobelProcera Alumina Crown coping production.
23 23 NobelProcera TM materials for all needs and indications. Currently, three materials are used in NobelProcera. NobelProcera Zirconia and Alumina are ceramic materials primarily used for copings, bridges, and abutments, whereas NobelProcera Titanium is a suitable alternative for bridge frameworks and bar-retained removable overdenture* solutions. Additional materials are under development and scheduled for release during All NobelProcera materials provide: High biocompatibility 6 8 Homogeneity no luting /soldering / welding of different components No local corrosive phenomena NobelProcera non-silica-based ceramics offer the following additional benefits: Ease of use with conventional cementation protocols High esthetic result all-ceramic restorations appear more natural-looking than those with metal cores Longevity dental ceramic research has resulted in materials that perform equally as well as cast restorations 9 Zirconia For long span and posterior restorations, NobelProcera Zirconia is the ceramic material of choice. Zirconia is a safe and reliable alternative to casting alloys for crowns and implant-retained superstructures, such as abutments and bridges. NobelProcera Zirconia is based on zirconium partially stabilized by the addition of % yttrium oxide (Y 2 O 3 ). The very fine grain structure and chemical composition of this material ( μm) contribute to its high flexural strength (1120 MPa average 28, 29 ) and fracture resistance (6 9 MPa m). 31 The material fracture strength of NobelProcera Zirconia means it is suited for all areas of the oral cavity where the primary requirements are strength and stability. 31 NobelProcera Zirconia: All locations using 0.7 mm thick coping Esthetic region using 0.4 mm thick coping Available in white and three colors: light, medium and intense Natural teeth or implant restorations single crowns and multi-unit bridges Customizable (CAD) using double scan / wax-up models NobelProcera Zirconia has satisfied the following standards and tests: The iron content of colored Zirconia is within the span given in ISO 13356:1997 Implants for Surgery Ceramic materials based on yttria-stabilized tetragonal zirconia (Y - TZP) Radioactive emission, flexural strength, and chemical solubility according to ISO 6872:1995 In vitro cytotoxicity according to Biological evaluation of medical devices Part 5: Tests for in vitro cytotoxicity (ISO :1999) SEM cross-section of densely sintered Zirconia. 20,000 x magnification. * Available in specific markets.
24 24 SEM cross-section of densely sintered Alumina. 5,000 x magnification. Alumina NobelProcera Alumina is best suited for solutions in esthetically demanding areas, such as the anterior dentition, due to its superior optical properties. NobelProcera Alumina in single-tooth restorations has been clinically proven for long-term clinical 1, 3, 33 success. NobelProcera Alumina copings are fabricated from a high-purity aluminum oxide (Al 2 O 3 ) powder. This ensures high flexural strength values ( MPa). 15 Titanium Since the discovery of titanium integrating with living bone, titanium has become the standard for dental implants. Titanium is highly biocompatible and produces excellent soft tissue response. Currently, two types of titanium are used in NobelProcera production: unalloyed Grade 2 titanium is used for the majority of abutments and bridges produced; and an alloyed Grade 5 titanium is used for NobelActive implant system abutments. SEM Grade 2 c.p. titanium turned surface. 500 x magnification. NobelProcera Alumina: Anterior and bicuspid region using either 0.4 mm or 0.6 mm thick copings Available in: translucent and white Natural teeth restorations single crown up to 4-unit bridges Customizable (CAD) using double scan / wax-up models NobelProcera Alumina has satisfied the following standards and tests: Radioactive emission, flexural strength, and chemical solubility according to ISO 6872:1995 In vitro cytotoxicity according to biological evaluation of medical devices Part 5: Tests for in vitro cytotoxicity (ISO :1999) Grade 2 titanium is a commercially pure (c.p.) grade titanium used primarily in surgical implant applications, and alloyed Grade 5 is 90 % titanium, 6 % aluminum, and 4 % vanadium (Ti6Al4V), which was developed for excellent strength. Both forms of NobelProcera Titanium have satisfied to the following general and specific standards and tests: General Tensile strength, proof stress of nonproportional elongation, percentage elongation according to ASTM E8 Specific Unalloyed titanium grade 2: Chemical Composition for Unalloyed Titanium for Surgical Implant Applications according to ASTM F67-06 Alloyed titanium: Standard Specification for Wrought Titanium - 6 Aluminum - 4 Vanadium ELI (Extra Low Interstitial) Allow for Surgical Implant Applications according to ASTM F136-02a
25 25 NobelProcera TM guaranteed and certified quality. All NobelProcera frameworks and copings delivered are covered against breakage and/or defect, and NobelProcera provides certificates of material authenticity. Guaranteed quality Nobel Biocare offers a comprehensive 5 -year warranty on all NobelProcera products. The homogeneity of materials and industrial fabrication processes guarantee high product quality with superb fit and surface finish for long-term clinical performance and patient satisfaction. With NobelProcera, meeting dental professionals expectations regarding delivery time, quality, safety and versatility is the ultimate guarantee. Warranty Terms and Conditions can be found on the NobelProcera website: Material purity NobelProcera provides certificates of material authenticity to dental laboratories on all frameworks and copings. These authenticity certificates are further illustrates of how Nobel Biocare and NobelProcera are dedicated to providing dental professionals with highly homogeneous materials and proven alloys upon which patient demands for esthetics and functionality can be met. Fulfilling high quality standards These certificates verify for the laboratory, dental professional, and ultimately the patient, that the NobelProcera materials, used in the productions of frameworks and copings, have been FDA cleared and satisfy all appropriate ISO and ASTM standards for materials used in dental devices. Each certificate comes in two parts: the laboratory that receives the original framework or coping retains one portion, and the dental professional who receives the final prosthetic retains the other portion with the patient treatment record. Titanium CERTIFICATE Titanium CERTIFICATE Zirconia CERTIFICATE Zirconia CERTIFICATE Alumina CERTIFICATE Alumina CERTIFICATE Nobel Biocare certifies that the core material provided to the laboratory with this certificate is FDA cleared Titanium. Material composition; Unalloyed Titanium Grade 2 or Alloyed Titanium-6Aluminum-4Vanadium (Ti6Al4V). Grade 2; Nitrogen 0.05%, Carbon 0.08%, Hydrogen 0.015%, Iron 0.30%, Oxygen 0.25%, Titanium = balance. For Ti6Al4V also; Aluminum 6.50%, Vanadium 4.50%. Material composition; Unalloyed Titanium Grade 2 or Alloyed Titanium-6Aluminum- 4Vanadium (Ti6Al4V). Grade 2; Nitrogen 0.05%, Carbon 0.08%, Hydrogen 0.015%, Iron 0.30%, Oxygen 0.25%, Titanium = balance. For Ti6Al4V also; Aluminum 6.50%, Vanadium 4.50%. Nobel Biocare certifies that the core ceramic material provided to the laboratory with this certificate is FDA cleared Zirconia. Material composition; Zirconium Oxide, Yttrium Oxide, Hafnium Oxide. Aluminum Oxide and other Oxides. ZrO2 + Y2O3 + HfO2 99.0%, Y2O3 > 4.5 to 6.0, HfO2 5%, Al2O3 0.5%. Other Oxides 0.5%. Material composition; Zirconium Oxide, Yttrium Oxide, Hafnium Oxide. Aluminum Oxide and other Oxides. ZrO2 + Y2O3 + HfO2 99.0%, Y2O3 > 4.5 to 6.0, HfO2 5%, Al2O3 0.5%. Other Oxides 0.5%. Nobel Biocare certifies that the core ceramic material provided to the laboratory with this certificate is FDA cleared Alumina. Material composition; Aluminum Oxide, Magnesium Oxide, Silicon Oxide, Calcium Oxide and Alkali Metal Oxides. Al2O3 99.5%, MgO 0.3%, SiO2 + CaO + Alkali Metal Oxides 0.1%. Material composition; Aluminum Oxide, Magnesium Oxide, Silicon Oxide, Calcium Oxide and Alkali Metal Oxides. Al2O3 99.5%, MgO 0.3%, SiO2 + CaO + Alkali Metal Oxides 0.1%. Clinician Copy Dental Laboratory Copy Clinician Copy Dental Laboratory Copy Clinician Copy Dental Laboratory Copy
26 26 NobelGuide complete treatment concept for dental implant rehabilitations. Complete treatment flexibility Single- and partial-unit to fully edentulous dental implant rehabilitations can be planned and performed. Excellent communication tool Tools make sharing planning information and facilitating decisionmaking within the cross-functional team easy. Versatility in loading strategy Surgical templates contain all the planning information and allow for minimally invasive procedures. Fully integrated supply chain All components for a single treatment can be ordered in the same order. Prosthetic driven Planning is from a prosthetic requirement perspective (backwards-planning).
27 27 NobelGuide TM digital precision for all indications. NobelGuide is a complete treatment concept for diagnosing, planning and placing dental implants, developed to work in harmony with the requirements of the future prosthetic restoration NobelGuide is the perfect partner assisting the entire team in making the appropriate treatment decisions and executing the planned result with high predictability. The digital integration of a conventional diagnostic tooth setup and full 3D view of the patient s anatomy in the software offer a profound basis for evaluating and defining implant positions for long-term success. 35,36 For all indications NobelGuide provides diagnosis, planning and implementation of dental implant rehabilitations for all indications * small partial-unit to fully edentulous cases. Functional, esthetic and biomechanical prosthetic considerations are optimized during the implant treatment planning phase. In fact, dental professionals can decide all elements of the treatment path, including the stage of implant loading (immediate or delayed loading), far in advance of the surgical procedure. 37 Prosthetic-driven planning The NobelGuide workflow benefits from a prosthetic-driven, backwards-planning approach. Based on the proposed final restoration, and a clinically evaluated tooth setup, a radiographic guide is generated. This radiographic guide serves as a template for attaining the expected function and esthetics of the final restoration. Integrated complete supply chain Based on the planning, a surgical template is automatically designed and ordered via the Internet from a production facility. The surgical template is produced with consistent quality and shipped back to the dental professional within a few working days. In the same order, implants, anchor pins to secure the template, drills and prosthetic components can be included. Minimally invasive The surgical template guides all implant treatment steps from drilling to implant insertion, and allows for safe flapless surgical protocols, which help minimize patient discomfort as well as pain and swelling. Safe and predictable treatment Careful diagnostics, optimized assessment of bone and prosthetic considerations allow for alignment of the entire treatment team, including the dental lab, and clear communication with the patient all of which lead to a treatment that is optimized for safety and meeting the high esthetic demands of the patient. Powerful indication-based diagnosis and treatment-planning platform. prosthetics. * Malo, P., M. de Araujo Nobre, and A. Lopes, The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean follow-up period of thirteen months. J Prosthet Dent, (6 Suppl): Marchack, C.B., CAD/CAM-guided implant surgery and fabrication of an immediately loaded prosthesis for a partially edentulous patient. J Prosthet Dent, (6): Sanna, A.M., L. Molly, and D. van Steenberghe, Immediately loaded CAD/CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients. J Prosthet Dent, (6): Balshi, S.F., Wolfinger, G.J. and Balshi,T.J.,Surgical planning and prosthesis construction using computer technology and medical imaging for immediate loading of implants in the pterygomaxillary region. Int J Periodontics Restorative Dent, (3):
28 28 Achieving excellent results with NobelProcera TM. Crowns Alumina Dr. Stefan Holst and DentalX GmbH, Germany. Three Crowns Alumina used to restore #14, #15 and #16, following endodontic treatment. Alumina was chosen for its excellent esthetics and biocompatibility. Occlusal intraoral view of maxillary bicuspid and premolars with extensive temporary core built-ups following endodontic treatment. Conventional preparation guidelines apply. A slight chamfer preparation and rounded edges are ideal for long-term clinical success. NobelProcera Software allows for ideal contour of copings to support veneering ceramics. NobelProcera Crown Alumina frameworks were chosen for esthetic and long-term success guarantee. Veneering can easily be achieved with conventional layering or press techniques. Final result showing an excellent soft tissue interface and natural-looking esthetics.
29 29 Implant Bridge Zirconia Dr. Eric Van Dooren, Luc and Patrick Rutten, Belgium. 65-year-old female patient with unesthetic restorations and extensive periodontal breakdown combined with recurrent decay. To correct this patient s extensive periodontal deficiencies, a complete jaw rehabilitation was necessary. Two Implant Bridges Zirconia were chosen for their excellent esthetics and biocompatibility. Implants were inserted with a provisional restoration. Occlusal intraoral view of abutment wax up, which will be scanned for CAD creation of the final prosthetic. For the final restoration, two NobelProcera Implant Bridges Zirconia (4-unit and 8-unit) were chosen. Note the soft tissue health and stability. Occlusal intraoral view of the restorations in place. Screw recesses are easily filled, but are accessible should bridges ever need to be removed. Three months after the placement, note the excellent soft tissue integration and stability.
30 30 High precision milling units produce high quality products.
31 31 Testimonials. The wide range of clinical applications and positive patient response has made NobelProcera an important part of our practice for some time. NobelProcera offers us a level of predictable esthetics with amazingly consistent fit and its cost effectiveness enables our group of four in-house technicians to focus on veneering, while leaving core production to NobelProcera. Dr Jonathan Ferencz, USA Dr Jonathan Ferencz, DDS, FACP Private practice limited to prosthodontics in New York City and Clinical Professor at NYU College of Dentistry, USA. Dr Enric Pintado, DDS Private practice in esthetics, prosthodontics and implant dentistry, and Director of Centre Dental Enric Pintado in Manresa, Spain. Mr Robert Hill Director of Robert Hill Ceramics Pty Ltd, a full-service NobelProcera laboratory in Melbourne, Australia. Mr Jean Robichaud, CDT, Fellow and Master of the ICOI Founding President of BioCad Medical Inc, developers of precision scanning and CAD design software in Quebec City, Canada. NobelProcera is the perfect tool for creating dental excellence. NobelProcera restorations have not only improved my professional value and increased my number of patients, they have strengthened the workflow within our entire team from impressions, provisionals, abutment design, material selection to final restoration. Dr Enric Pintado, Spain NobelProcera has been our choice for CAD /CAM technology since We specialize in producing single unit and bridge prosthetics for implant restorations. Products such as NobelProcera Implant Bridge for partial and full arch offer us an extensive choice of restorative options; and, the titanium bars/frames and zirconia subframes always fit perfectly. These products create savings in time and materials, which make them the most cost-effective, predictable and functional choices available. Mr Robert Hill, Australia NobelProcera provides dental technicians the complete solution they need to get involved in serious CAD /CAM from the most efficient crown and bridge design tools to the more complex implantologyrelated applications. The new NobelProcera CAD software version is going to unveil a whole new world of exciting projects for all Nobel Biocare customers. Mr Jean Robichaud, Canada
32 32 References. 1 Odman P, Andersson B. Procera AllCeram crowns followed for 5 to 10.5 years: a prospective clinical study. Int J Prosthodont 2001;14(6): Örtorp A, Jemt T. Clinical experiences of computer numeric control milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study. Clin Implant Dent Relat Res 2004;6(4): Zitzmann NU, et al. Clinical evaluation of Procera AllCeram crowns in the anterior and posterior regions. Int J Prosthodont 2007;20(3): Kokubo Y, Ohkubo C, Tsumita M, Miyashita A, Vult von Steyern P, Fukushima S. Clinical marginal and internal gaps of Procera AllCeram crowns. J Oral Rehabil 2005;32: Adolfi D, De Freitas AJ, Groisman M. Achieving aesthetic success with an immediate-function implant and customized abutment and coping. Pract Proced Aesthet Dent 2005; 17(9): Bonnard P, et al. Anterior esthetic rehabilitation on teeth and dental implants optimized with Procera technology:a case report. J Esthet Restor Dent 2001;13(3): Zarone F, et al. Retrospective clinical evaluation of 86 Procera AllCeram anterior single crowns on natural and implant-supported abutments. Clin Implant Dent Relat Res 2005;7 Suppl 1: Takahashi T, Gunne J. Fit of implant frameworks: an in vitro comparison between two fabrication techniques. J Prosthet Dent 2003;89(3): Sierraalta, M, Razzoog ME. Load to Fracture of Procera Zirconia Bridges. J Dent Res 2006;85 (Spec Iss A) : abstract Att W, Stamouli K, Gerds T, Strub JR. Fracture resistance of different zirconium dioxide three-unit all-ceramic fixed partial dentures. Acta Odontol Scand 2007;65: Gonzalo E, Suárex M, Serrano B, Lozano JF. Marginal fit of zirconia posterior fixed partials dentures. Int J Prosthodont 2008;21: Chu FC, et al. Making porcelain veneers with the Procera AllCeram system: case studies. Dent Update 2003;30(8):454 8, Hager B, et al. Procera AllCeram laminates: a clinical report. J Prosthet Dent 2001;85(3): Örtorp A, et al. Comparisons of precision of fit between cast and CNC milled titanium implant frameworks for the edentulous mandible. Int J Prosthodont 2003;16(2): Degidi M, et al. Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri-implant soft tissues around titanium and zirconium oxide healing caps. J Periodontol 2006;77(1): Hisbergues M, Vendeville S, Vendeville P. Zirconia: Established facts and perspectives for a biomaterial in dental implantology. J Biomed Mater Res B Appl Biomater 2008;17 [E-pub ahead of print]. 8 Thomas P, et al. Immuno-allergological properties of aluminum oxide (Al 2 O 3 ) ceramics and nickel sulfate in humans. Biomaterials 2003;24(6): Pjetursson BE, et al. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns. Clin Oral Implants Res 2007;18 Suppl 3: Sierraalta M, Oden A, Razzoog ME. Material strength of zirconia produced with two methods. J Dent Res 2003;82(Spec Iss A):abstract # Wagner WC, Chu TM. Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics. J Prosthet Dent 1996;76(2): Chu FC, Chow TW, Chai j. Contrast ratios and masking ability of three types of ceramic veneers. J Prosthet Dent 2007;98(5): Kessler-Liechti G, Mericske-Stern R. Rehabilitation of an abraded occlusion with Procera- ZrO 2 all-ceramic crowns. A case report. Schweiz Monatsschr Zahnmed 2006;116(2): Att W, Grigoriadou M, Strub JR. ZrO2 three-unit fixed partial dentures: comparison of failure load before and after exposure to a mastication simulator. J Oral Rehabil 2007;34(4): Lang BE, et al. Procera AllCeram Bridge. Appl Osseointegrat Res 2004;4: Raffaelli L, Iommetti PR, Piccioni E, Toesca A, Serini S, Resci F, Missori M, De Spirito M, Manicone PF, Calviello G. Growth, viability, adhesion potential, and fibronectin expression in fibroblasts cultured on zirconia or feldspatic ceramics in vitro. J Biomed Mater Res A ;86: Scarano A, Piatelli M, Caputi S, Favero GA, Piattelli A. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol 2004;75: Holst S, Geiselhöringer H, Nkenke E, Blatz MB, Holst Ai. Updated implant retained restorative solutions in patients with hypdontia. Qiuntessence Int 2008;39: Nordic Institute of Dental Materials (NIOM) Zirconia testing: S306269B, S306205B. 29 Nobel Biocare internal measurements. Data on file.
33 33 30 Rasperini G, Maglione M, Cocconcelli P, Simion M. In vivo early plaque formation on pure titanium and ceramic abutments: a comparative microbiological and SEM analysis. Clin Oral Implants Res 1998;9: Kelly JR, Denry I. Stabilized zirconia as a structural ceramic: an overview. Dent Mater 2008;24: Miskinis SB, Snyder M, Sieraallta M, Billy E, Razzoog ME. Effect of varying coping thickness on early load-to-fracture strength of Procera AllCeram copings cemented with 2 resin-modified glass ionomer cements. Quintessence Int 2008;39(6): Oden A, et al. Five-year clinical evaluation of Procera AllCeram crowns. J Prosthet Dent 1998;80(4): van Steenberghe D, Glauser R, Blombäck U, Andersson M, Schutyser F, Pettersson A, Wendelhag I. A computed tomography scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clin Implant Dent Relat Res 2005;7 Suppl 1: Sanna AM, Molly L, van Steenberghe D. Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients. J Prosthet Dent 2007;97(6): Katsoulis J, Pazera P, Mericske-Stern R. Prosthetically Driven, Computer-Guided Implant Planning for the Edentulous Maxilla: A Model Study. Clin Implant Dent Relat Res Sep 9 [E-pub ahead of print]. 37 Malo P, de Araujo Nobre M, Lopes A. The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean follow-up period of thirteen months. J Prosthet Dent Mar;99(3):167.
34 34 Support, Education and Guarantee. Partner Support To support the nearly 4,000 NobelProcera laboratories already existing around the world, a tightly woven network of customer services representatives has been created, which is underpinned by the three NobelProcera production centers. All NobelProcera customers are automatically connected to the NobelProcera Network that provides: Information access Marketing support Educational materials On-line education Contact with laboratories all over the world Technical support NobelProcera scanners and equipment are covered under a NobelProcera Service Contract. Additionally, any necessary remakes are free of charge and come with the same 5-year warranty carried by every NobelProcera product (see below). Educational Programs The complete education offer for NobelProcera from evening seminars, one or more days programs to World Tour congresses, inexperienced to advanced users, and around the globe is available at Training and education activities are led by international and local experts. Warranty Terms and Conditions NobelProcera products on teeth and implants are guaranteed for five years against breakage or defect; the NobelProcera product warranty only covers the NobelProcera products and does not include any additional costs. Dental professionals must have complied with the handling and material instructions of Nobel Biocare as published at the time of preparation, design and finishing. Non-compliance with the procedures and instructions published by Nobel Biocare will make the warranty null and void. Dental professionals must ensure that patients comply with generally accepted standards of good oral hygiene. Implants and NobelProcera restorations that fail as a result of poor hygiene maintenance and /or infections may not be covered under the warranty. For implants, oral hygiene maintenance examinations twice a year are recommended. Nobel Biocare shall not be obliged to furnish benefits under this warranty with respect to any Nobel Biocare implant if the failure of such an implant or NobelProcera product is caused by trauma or by the patient in whom such an implant was installed. This warranty is exclusively for the benefit of eligible dental professionals and is not for any other person or entity, including any patient.
35 35 Nobel Biocare worldwide. Europe and Russia Austria Nobel Biocare Austria Phone: Belgium Nobel Biocare Belgium Phone: Denmark Nobel Biocare Denmark Phone: Finland Nobel Biocare Finland Phone: France Nobel Biocare France Phone: Germany Nobel Biocare Germany Phone: Hungary Nobel Biocare Hungary Phone: Ireland Nobel Biocare Ireland Phone: toll free Italy Nobel Biocare Italy Phone: Cust. support: toll free Lithuania Nobel Biocare Lithuania Phone: Cust. support: toll free Netherlands Nobel Biocare Netherlands Phone: Norway Nobel Biocare Norway Phone: Poland Nobel Biocare Poland Phone: Cust. support: Portugal Nobel Biocare Portugal Phone: Cust. support: toll free Russia Nobel Biocare Russia Phone: Spain Nobel Biocare Spain Phone: Cust. support: toll free Sweden Nobel Biocare Sweden Phone: Cust. support: Switzerland Nobel Biocare Switzerland Phone: United Kingdom Nobel Biocare UK Phone: North America Canada Nobel Biocare Canada Phone: Cust. support: USA Nobel Biocare USA Phone: Cust. support: Central/South America Argentina Nobel Biocare Argentina Phone: Cust. support: toll free Brazil Nobel Biocare Brazil Phone: Cust. support: Chile Nobel Biocare Chile Phone: Colombia Nobel Biocare Colombia Phone: Cust. support: toll free Mexico Nobel Biocare Mexico Phone: Asia Pacific Australia Nobel Biocare Australia Phone: Cust. support: toll free China Nobel Biocare China Phone: Cust. support: Hong Kong Nobel Biocare Hong Kong Phone: Cust. support: India Nobel Biocare India Phone: Cust. support: toll free Japan Nobel Biocare Japan Phone: New Zealand Nobel Biocare New Zealand Phone: Cust. support: toll free Singapore Nobel Biocare Singapore Phone: Cust. support: Taiwan Nobel Biocare Taiwan Phone: Middle East and Africa Israel Nobel Biocare Israel Phone: Middle East Nobel Biocare Middle East Phone: South Africa Nobel Biocare South Africa Phone: v 9.1
36 C GB 1005 Printed in Sweden Nobel Biocare Services AG, All rights reserved. Nobel Biocare, the Nobel Biocare logotype and all other trademarks used in this document are, if nothing else is stated or is evident from the context in a certain case, trademarks of Nobel Biocare. Product images in this brochure are not necessarily to scale.
All-on-4 treatment concept with NobelSpeedy Groovy
All-on-4 treatment concept with NobelSpeedy Groovy Product overview Immediate Function for high patient satisfaction Immediately loaded fixed provisional prosthesis on the day of surgery. Immediate improvement
Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental
Implant Solutions for the Implant Patient: Diagnosis and Treatment Planning for Predictable Results David Little, DDS 6961 U.S. Highway 87 East San Antonio, TX 78263 Phone: (210)648-4411 Fax: (210) 648-6498
A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection
A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection Sanjay Karunagaran, B.D.S., D.D.S., M.S.D., Gregory J. Paprocki, D.D.S., Russell Wicks, D.D.S., M.S., Sony Markose, B.D.S.,
Press Abutment Solutions
Press Abutment Solutions Efficiency and esthetics redefined all ceramic all you need More press ceramic options... Press ceramics have been synonymous with the ideal combination of accuracy of fit, shape
FABRICATING CUSTOM ABUTMENTS
FABRICATING CUSTOM ABUTMENTS LUC AND PATRICK RUTTEN How much should a Dental Technician know about the clinical aspects of implantology? The answer is clear: as much as possible. This is the distinction
priti crown Your patients deserve you
priti crown Your patients deserve you 3 and you deserve the priti crown So close to nature priti crown is a high-tech solution for making perfect crown and bridge restorations using state-of-the-art CAD/CAM
ATLANTIS crown abutment. Patient-specific CAD/CAM abutments for single-tooth, screw-retained restorations
ATLANTIS crown abutment Patient-specific CAD/CAM abutments for single-tooth, screw-retained restorations Excellent results every time For all major implant systems DENTSPLY Implants now offers the appreciated
Procedures & Products. NobelEsthetics
Procedures & Products NobelEsthetics First from Nobel Biocare. NobelPerfect, (NP, RP, WP), NobelDirect (NP, RP, WP), Brånemark System, NobelReplace and NobelSpeedy Implants. A complete assortment with
ATLANTIS abutments as individual as your patients
ATLANTIS abutments as individual as your patients ATLANTIS the freedom of unlimited possibilities Discover why ATLANTIS CAD/CAM abutments are the natural choice for patientspecific, cement-retained implant
ATLANTIS ISUS the benchmark for CAD/CAM suprastructures. For all major implant systems
ATLANTIS ISUS the benchmark for CAD/CAM suprastructures For all major implant systems Patient satisfaction meets clinical benefits ATLANTIS delivers leading CAD/CAM patient-specific restorative solutions
Standard Internal Hex
Standard Internal Hex Touareg TM -OS Touareg TM -S Swell TM Touareg -S Touareg -OS Swell About ADIN Adin Dental Implant Systems Ltd., designs, manufactures and markets state of the art, technologically
Abutment Solutions For customized implant restorations fabricated with CEREC and inlab. Digital all around.
Abutment Solutions For customized implant restorations fabricated with CEREC and inlab Digital all around. The digital treatment workflow Digital impression taking Coordinated digital workflows in CAD/CAM
Dental Laboratories. Procera provides you access to our multi-million dollar production facility
Dental Laboratories provides you access to our multi-million dollar production facility minimal investment maximum rewards strong, beautiful, proven products are famous for their excellent strength and
Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT
Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT Introduction A 58 year old male had been missing teeth #7=12 for approximately 28 years. During
STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment
STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES Straumann Anatomic IPS e.max Abutment The ITI (International Team for Implantology) is academic partner of Institut Straumann in the areas of research
How to Achieve Shade Harmony With Different Restorations
Procera Alumina vs. Feldspathic Porcelain How to Achieve Shade Harmony With Different Restorations Luke S. Kahng, CDT Key Words: Stump shade, Feldspathic Porcelain, Zirconia, Alumina, LSK Treatment Plan
ATLANTIS abutments design guide CAD/CAM patient-specific abutments
ATLANTIS abutments design guide CAD/CAM patient-specific abutments Contents Introduction 4 This manual helps you to explore all the benefits of ATLANTIS CAD/CAM patient-specific abutments. It gives you
Long-term success of osseointegrated implants
Against All Odds A No Bone Solution Long-term success of osseointegrated implants depends on the length of the implants used and the quality and quantity of bone surrounding these implants. As surgical
ALL-CERAMIC DENTAL IMPLANT SOLUTIONS
ALL-CERAMIC DENTAL IMPLANT SOLUTIONS Scientific Evidence Bone-to-implant contact of 78% at 3 months. One piece implant = no prosthetic connections References 1. One-year follow-up of first consecutive
More than a fixed rehabilitation.
More than a fixed rehabilitation. A reason to smile. In combination with: Patient expectations drive dental treatments for fixed edentulous immediate restorations. Patients today have increasingly high
BICON DENTAL IMPLANTS
BICON DENTAL IMPLANTS The Bicon Dental Implant System, since 1985, has offered discerning dentists the ability to provide secure implant restorations that look, feel, and function like natural teeth. With
CAD/CAM. Solutions flexible, economical, future-proof
CAD/CAM Solutions flexible, economical, future-proof What would you like to use CAD/CAM solutions for today and tomorrow? Custom abutments Crown and bridge restorations Segments within prosthetics in the
State-of-the-art for your prostheses
WHERE CREATIVITY meets technology E CREATECH EXCELLENCE State-of-the-art technology for your prostheses 1 CREATECH EXCELLENCE What is createch Excellence? Createch Excellence is OUR RANGE OF SOLUTIONS
Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration
Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration ROBERT SCHNEIDER, DDS, MS* ABSTRACT The prosthetic restoration of a
platform shifting Nobel Biocare is shifting gingival beauty to the next level
platform shifting Nobel Biocare is shifting gingival beauty to the next level Nobel Biocare is shifting gingival beauty to the next level Platform Shifting is the latest in Nobel Biocare s offering of
Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment
Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment by Dr. Ronald Jung and Master Dental Technician Xavier Zahno Initial situation
Simpl Implant Abutments with Atlantis CAD CAM Technology
Simpl Implant Abutments with Atlantis CAD CAM Technology Don t change your implant... change your abutment. See more patients in less time... and save money in the process! See how we ve made it Simpl.
WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca
WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca Duration: 6 meses STEP 1: WAX-UP OF FOUR UPPER POSTERIOR TEETH with Dr. Ivan Ronald Huanca The objective of this course s step
procedures & products NOBELESTHETICS including Procera
procedures & products NOBELESTHETICS including Procera First from Nobel Biocare. NOBELPERFECT, (NP, RP, WP), NOBELDIRECT (NP, RP, WP), Brånemark System, NOBELREPLACE and NOBELSPEEDY Implants. A complete
Prosthetic treatment planning on the basis of scientific evidence.
Prosthetic treatment planning on the basis of scientific evidence. Pjetursson BE, Lang NP. J Oral Rehabil. 2008 Jan;35 Suppl 1:72-9. Faculty of Odontology, University of Iceland, Reykjavik, Iceland, and
Implants in your Laboratory: Abutment Design
1/2 point CDT documented scientific credit. See Page 41. Implants in your Laboratory: Abutment Design By Leon Hermanides, CDT A patient s anatomical limitations have the greatest predictive value for successful
BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment
BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT Straumann Variobase Abutment 1 The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of research
Accelerated Patient Rehabilitation
Accelerated Patient Rehabilitation Providing The Tools Necessary For An Immediate Solution: NanoTite Implants QuickBridge Provisional Components Navigator System For CT Guided Surgery Initial Patient Presentation
education Although demographic factors and growing patient awareness of the benefits of dental implants
education Increasing implant dentistry in undergraduate education using new technology: A pilot project Hugo De Bruyn, MDS, MsC, PhD ± & Stefan Vandeweghe, DDS Although demographic factors and growing
It s the Fuel For Your Success
It s the Fuel For Your Success Engineered For Success Today s patients demand aesthetic restorative outcomes that match or enhances their natural dentition. While this has traditionally been accomplished
Renaissance of One-Piece Implants
2 EDI Minimally invasive and patient-friendly treatment concepts using one-piece implants Renaissance of One-Piece Implants Hannes Thurm-Meyer, dentist, Bremen, Germany, Thomas Horn, master dental technician,
Implant solutions. 3M True Definition Scanner. Precise. implant impressions. with incredible speed
Implant solutions 3M True Definition Scanner Precise implant impressions with incredible speed True Definition Scanner You know in advance that it will be as desired The desired impression fast. The precise
SCD Case Study. Treatment Considerations for Implant Rehabilitation
SCD Case Study Treatment Considerations for Implant Rehabilitation Multiple surgical and restorative factors play a role in the treatment planning of implant restorations for the edentulous patient (Ali
TRI Product NewsFlash. December 2015
TRI Product NewsFlash December 2015 Study Overview 2015 Dear Partners Year in, year out, we are screening all major scientific journals to ensure that our TRI Performance Concept still reflects the latest
Full Mouth Restoration with Screw-Retained Zirconia Bridges
Full Mouth Restoration with Screw-Retained Zirconia Bridges A DENTIST-LAB RELATIONSHIP THAT WORKS Dentist: Steven P. Stern, DMD Windsor Dental Center New Windsor, NY Dental Laboratory: InnoDDS Dental Laboratory
Contact: Steve Hurson VP, R & D Nobel Biocare 22715 Savi Ranch Pkwy Yorba Linda, CA 92887 (714) 282-5072 steve.hurson@nobelbiocare.
Use of CP Titanium and Titanium alloys for Dental Implants Steve Hurson, Nobel Biocare U.S.A. Yorba Linda CA Abstract Professor Per Ingvar Branemark of Sweden published his results on 15 years of research
DESS. Screws. Tijuana Ventas: (664) 685 6294/95 [email protected]. For all major implant systems!! www.dabocorp.com
Screws Screws for definitive use. Made from medical grade 5 ELI Titanium Integrity and soundness guaranteed by stress tests of up to 150% of their nominal torques. Their designs ensure a perfect fit with
Seeing CAD/CAM in a new light.
CAD/ CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS CEREC NEW PRODUCTS 2009 Seeing CAD/CAM in a new light. T h e D e n t a l C o m p a n y Precision and simplicity redefined.
How To Use Nobelbiocare'S Integrated Treatment Workflow
The key to successful treatments NobelClinician Software Visualize what you need to see with the unique SmartFusion technique. Increase efficiency with the integrated treatment workflow. Collaborate more
Clinical and Laboratory Procedures for Fixed Margin Implant Abutments
Clinical and Laboratory Procedures for Fixed Margin Implant Abutments Dr. Carl Drago DDS, MS, American Board of Prosthodontics Director, Dental Research BIOMET 3i, Adjunct Faculty Department of Prosthodontics,
DS6000. Advanced Dental Scanner & CAD Software. Crowns, Bridges Wax-ups Implant Bridges and Bars High Accuracy Scan & Design
DS6000 Advanced Dental Scanner & CAD Software Crowns, Bridges Wax-ups Implant Bridges and Bars High Accuracy Scan & Design Inlay/Onlays DICOM Viewer Custom Abutments Virtual Articulator CAM Module DS6000
Ridge Reconstruction for Implant Placement
Volume 1, No. 5 July/August 2009 The Journal of Implant & Advanced Clinical Dentistry Ridge Reconstruction for Implant Placement 2 Hours of CE Credit Oral Implications of Cancer Chemotherapy Immediate
CAD/CAM technology supporting successful implant therapy
CAD/CAM technology supporting successful implant therapy Suheil M. Boutros, DDS, MS, Manuel Fricke, DT Modern implantology opens up new treatment options for individuals with only minimal or no remaining
Implant Bar Overdenture Utilizing Locator Attachments
Utilizing Locator Attachments Step-by-Step Restorative Protocol Implant Bar Overdentures offer a removable implant solution for edentulous patients desiring a stable and esthetic prosthesis that improves
Treatment planning for the class 0, 1A, 1B dental arches
Treatment planning for the class 0, 1A, 1B dental arches Dr.. Peter Hermann Dr Reminder: Torquing movement on tooth supported denture : no movement Class 1 movement in one direction (depression) Class
ADA Insurance Codes for Laboratory Procedures:
ADA Insurance Codes for Laboratory Procedures: Inlay/Onlay Restorations D2510 Inlay - metallic - one surface D2520 Inlay - metallic - two surfaces D2530 Inlay - metallic - three or more surfaces D2542
Restorative Guidelines
Restorative Guidelines Contents Restorative Guidelines 4.1 Neoss Implant System 4.2 4.2 Esthetiline Solution 4.3 4.3 Provisional Abutments 4.8 4.4 Impression Techniques Implant Level 4.12 4.5 NeoLink
Modern Tooth Replacement Strategies & Digital Workflow
Modern Tooth Replacement Strategies & Digital Workflow Case Studies by Dr Maurice Salama, DMD AS PUBLISHED BY Dentistry Today, June 2014 Complete Implant Restoration System FACTS: Implant Dentistry Has
Restoring quality to life. Dental implants. A naturally better solution. Patient Education
Restoring quality to life. Dental implants. A naturally better solution. Patient Education Dental implants: A better treatment option. What are dental implants? Dental implants are a safe, medically proven,
IMPLANT DENTISTRY EXAM BANK
IMPLANT DENTISTRY EXAM BANK 1. Define osseointegration. (4 points, 1/4 2. What are the critical components of an acceptable clinical trial? (10 points) 3. Compare the masticatory performance of individuals
Like natural teeth. Treatment with dental implants is a safe, reliable and well-proven solution for permanently replacing one or more missing teeth.
Implants for life 2 IMPLANTS FOR LIFE Like natural teeth Treatment with dental implants is a safe, reliable and well-proven solution for permanently replacing one or more missing teeth. Millions of people
Choosing the right type of abutment
50 Producing custom implant abutments using CAD/CAM Choosing the right type of abutment S. KHALILOVA 1, F. KISTLER 2, S. ADLER 3, S. WEISS 3, S. KISTLER 2 AND J. NEUGEBAUER 2,4 Rapid developments in the
DENT IMPLANT restoring qualit S: of LIfE
DENTAL IMPLANTS: restoring quality of life Dental Implants: A Better Treatment Option. What are dental implants? Dental implants are a safe, esthetic alternative to traditional crowns, bridgework, and
While the prosthetic rehabilitation of
Restoring Mandibular Single Teeth with the Inclusive Tooth Replacement Solution Go online for in-depth content by Bradley C. Bockhorst, DMD While the prosthetic rehabilitation of full-arch cases provides
Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation
Smile Confidently With DIEM 2 Immediate Full Arch Rehabilitation Immediate Full Arch Rehabilitation * Edentulism and failing dentition continue to be major health challenges affecting millions of people
Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw
38 STARGET 1 I 11 ceramic restorations arne F. BOEcklER and MIcHaEl seitz Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw Introduction
Flexible dentures an alternate for rigid dentures? Volume 1 Issue 1
Flexible dentures an alternate for rigid dentures? Dr. Sunitha N Shamnur 1, Dr. Jagadeesh KN 1, Dr. Kalavathi SD 1, Dr. Kashinath KR 2 1 Senior Lecturer, 2 Professor & Head, Department of Prosthodontics,
Implant Parts. A Radford Heath Guide http://www.radfordheath.com 1
Implant Parts A Radford Heath Guide http://www.radfordheath.com 1 Disclaimer The information given in this document has been provided in good faith for basic information purposes only and the information
Peri-implant soft-tissue health surrounding cement- and screw-retained implant restorations: a multi-center, 3-year prospective study.
Peri-implant soft-tissue health surrounding cement- and screw-retained implant restorations: a multi-center, 3-year prospective study. Weber HP, Kim DM, Ng MW, Hwang JW, Fiorellini JP. Clin Oral Implants
Abutment fracture in a bridge supported by natural teeth and implants
Abutment fracture in a bridge supported by natural teeth and implants Authors_Dr Gregory-George Zafiropoulos, Dr Giorgio Deli & Dr Rainer Valentin, Germany/Italy _Introduction Implant treatment has evolved
Computer-assisted design (CAD) and computerassisted
CAD/CAM Technology for Implant Abutments, Crowns, and Superstructures Theodoros Kapos, DMD, MMSc 1 /Christopher Evans, BDSc Hons (Qld), MDSc (Melb) 2 Purpose: The aim of this systematic review was to compare
The Transition from Teeth to Implants and the Use of Post-ceramic Soldering
The Transition from Teeth to Implants and the Use of Post-ceramic Soldering Basil Mizrahi, BDS, MSc, MEd* Anthony Laurie, RDT, FCGI, FBIDST** D ental implants have become a widely accepted and successful
What is a dental implant?
What is a dental implant? Today, the preferred method of tooth replacement is a dental implant. They replace missing tooth roots and form a stable foundation for replacement teeth that look, feel and function
Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment
Contents TS Implant System Cement retained restoration Screw retained restoration 06 Cement-retained bridges with the Solid abutment system (non- 72 Screw retained crown with the ComOcta Gold abutment
Dental implants and Astra Tech
Background Dental implants and Astra Tech March 2009 1/6 CONTENTS Tooth loss: A common problem... 3 Traditional solutions... 3 Dental implants... 4 Astra Tech Implant System..... 4 Atlantis - patient-specific
CEREC inlab the multifunctional CAD/CAM system for modern dental restorations.
CEREC inlab the multifunctional CAD/CAM system for modern dental restorations. CEREC inlab technology CEREC inlab progress coupled with experience: Sirona s leading-edge CAD/CAM system. Sirona: a leading
Straumann Bone Level Tapered Implant Peer-to-peer communication
Straumann Bone Level Tapered Implant Peer-to-peer communication Clinical cases April, 2015 Clinical Cases Case No. Site 1 Single unit; Anterior Maxilla 2 Multi-unit; Anterior Maxilla Implant placement
Straumann Dental implant system ONE SYSTEM ONE INSTRUMENT KIT ALL INDICATIONS*
Straumann Dental implant system ONE SYSTEM ONE INSTRUMENT KIT ALL INDICATIONS* For all indications*! The Straumann Dental Implant System offers you and your patients efficient and esthetic implant-borne
CUSTOMIZED PROVISIONAL ABUTMENT AND PROVISIONAL RESTORATION FOR AN IMMEDIATELY-PLACED IMPLANT
CONTINUING EDUCATION 1 4 CUSTOMIZED PROVISIONAL ABUTMENT AND PROVISIONAL RESTORATION FOR AN IMMEDIATELY-PLACED IMPLANT Gerard J. Lemongello, Jr, DMD* LEMONGELLO 19 7 AUGUST The use of immediate implant
Tooth Replacement Options
Dr. Jordan Johnson Johnson Dental Associates http://www.beta.mydentalhub.com/ada/test/ (800) 947-4746 Tooth Replacement Options If you re missing one or more teeth, you may be all too aware of their importance
páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí
kéï=~ë=çñw= MRKOMNP páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí lééê~íáåö=fåëíêìåíáçåë båöäáëü=erpf Operating Instructions = Sirona Dental Systems GmbH Table of contents 1 Symbols used... 3 2 Product description...
CDT 2015 Code Change Summary New codes effective 1/1/2015
CDT 2015 Code Change Summary New codes effective 1/1/2015 Code Nomenclature Delta Dental Policy D0171 Re-Evaluation Post Operative Office Visit Not a Covered Benefit D0351 3D Photographic Image Not a Covered
Titanium versus Zirconium Implants
Titanium versus Zirconium Implants A dental materials comparison Dr. Gerald Regni, DMD!!" Christian St. Phila. PA 1213" T: (""") %&'-!"#" E: [email protected] Titanium versus Zirconium Implants
INSPIRED BY NATURE: CHRISTIAN FERRARI FULL FUNCTIONAL AND ESTHETIC MINIMALINVASIV RESTORATION USING IPS E.MAX CERAMICS
DENTAVANTGART VOLUME IV ISSUE 03 AUTUMN 2014 INTERVIEW DR. VIOLETA BARTALIS ÉP. CLAUS & ZTM. JAN-HOLGER BELLMANN & DR. CARSTEN CLAUS DR. ATTILA BODROGI & CDT. SIMONE MAFFEI DR. CYRIL GAILLARD & CDT. JÉRÔME
LEBENSLAUF Dent. Dr. ÖZGE ÖZTÜRK
LEBENSLAUF Dent. Dr. ÖZGE ÖZTÜRK 1. EDUCATION AND TRAINING Year Position/Title School/University Field 1987-1994 Student T.E.D. Ankara College, Ankara, TURKEY High School (honour student) 1994-1999 Student
Rehabilitation of Endondontically Failed Anterior teeth by Immediate Replacement and Loading of an Implant supported Crown: A Case Report.
RESEARCH AND REVIEWS: JOURNAL OF DENTAL SCIENCES Rehabilitation of Endondontically Failed Anterior teeth by Immediate Replacement and Loading of an Implant supported Crown: A Case Report. Lalit Kumar 1
Aesthetics meets CAD/CAM in the dental surgery
62 EDI New state-of-the-art options for implant-supported restorations Aesthetics meets CAD/CAM in the dental surgery Dr Mathias Siegmund, M.Sc., Regensburg, Germany Thanks to the new Sub-Tec CAD/CAM TiBase
your talent. our technology. the perfect fit.
your talent. our technology. the perfect fit. itero - exclusively distributed in Europe by The digital revolution Changing the Face of Dentistry Digital technology ensures a more accurate impression from
Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.
Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment. Dr. med. dent. David McFadden, Dallas County, USA Initial situation (single X-ray) Tooth 16
IMPLANTS IN FOCUS. Endosseous dental implant restorations PLANNING FOR IMPLANT RESTORATIONS
IMPLANTS IN FOCUS PLANNING FOR IMPLANT RESTORATIONS Replacing a missing maxillary central incisor with a dental implant can be the most demanding restoration in dentistry, so it s important to consider
Zfx & Zimmer Dental. Joining together for high-end dental prostheses
Zfx & Zimmer Dental Joining together for high-end dental prostheses Zfx & Zimmer Dental The new complete dental solution Cooperation: Zfx and Zimmer Dental join forces With Zfx as its CAD/CAM partner,
Choose What Feels Right. Bridge vs. Dental Implant
Choose What Feels Right Bridge vs. Dental Implant THE CHOICE THAT FEELS RIGHT A missing tooth just doesn t feel right. It can be uncomfortable, make it difficult to chew and perhaps worst of all, hold
Procedures & Products Powered by Procera. All-on-4
Procedures & Products Powered by Procera All-on-4 First from Nobel Biocare. NobelPerfect, (NP, RP, WP), NobelDirect (NP, RP, WP), Brånemark System, NobelReplace and NobelSpeedy Implants. A complete assortment
Attachments And Their Use In Removable Partial Denture Fabrication
Unless otherwise noted, the content of this course material is licensed under a Creative Commons Attribution - Non-Commercial - Share Alike 3.0 License. Copyright 2008, Dr. Jeff Shotwell. The following
Nobel Clinician - Quick Guide
1220 E. Birch St. #201 Brea, CA 92821 (800)750-5004 Haupt Dental Lab Inc. Nobel Clinician - Quick Guide Step #1 - Diagnostics Make impressions of both the upper and lower arches using custom trays. Care
ZIRCONIA INFORMATION FOR DENTISTS. FAQ S from the dental practice ENGLISH
ZIRCONIA INFORMATION FOR DENTISTS FAQ S from the dental practice ENGLISH Zr Facts and Answers 2 Facts and Answers What is Zirconia? Zirconium (ZrSiO ) belongs to the mineral group of silicates and 4 was
Milled Bar Overdentures-Protocol and Procedures
Milled Bar Overdentures-Protocol and Procedures Dennis Urban, CDT When full implant dentures requiring a milled bar is prescribed, the proper protocol and procedure are of extreme importance. The proper
PRECISION, RELIABILITY, SIMPLICITY. simeda. customized. & solutions. Digital performance
PRECISION, RELIABILITY, SIMPLICITY simeda customized & solutions Digital performance 2 Simeda Scan The high-precision scanner for implantology! With, a company specialised in industrial metrology, Simeda
Dental Implants - the tooth replacement solution
Dental Implants - the tooth replacement solution Are missing teeth causing you to miss out on life? Missing teeth and loose dentures make too many people sit on the sidelines and let life pass them by.
