Understanding NERC-CIP-014, and the Associated Communications Equipment Infrastructure for Electrical Substation Physical Security
|
|
|
- Myron O’Neal’
- 10 years ago
- Views:
Transcription
1 WHITE PAPER:, and the Associated Communications Equipment Infrastructure for Electrical Substation Physical Security By Bruce M. Berman ComNet Vice President of New Business Development 3 CORPORATE DRIVE DANBURY, CT USA T: F: TECH SUPPORT: [email protected] 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS, UK LS27 7LE T: +44 (0) F: +44 (0) [email protected]
2 INTRODUCTION For most of the history of the electric power transmission and distribution industry, electrical substations were thought of as assets with relatively minimal physical security concerns. The chain-link fences surrounding them, and the well-known and ominous sounding Danger-High Voltage, Keep Away signs were usually sufficient to prevent unauthorized entry to or vandalism of these facilities, and more recently, the prevention of theft of valuable copper and other costly materiel. Largely unreported within the media, the Pacific Gas & Electric (PG & E) Metcalf substation in San Jose, California, supplying power to the Silicon Valley area was vandalized in April, 2013, with a sniper damaging insulator bushings on 17 power transformers, resulting in $17 million in damage. The incident, which happened shortly after midnight, began when fiber-optic communication lines were severed in two underground vaults near the substation. The probable objective of the vandal was to create a widespread power outage, but fortunately the utility was able to reroute power at the facility, and the public experienced no outages. Another incident occurred in August of 2014; materials were stolen from a construction trailer located at the Metcalf site. Both incidents dramatically underscored the issue surrounding physical security as it relates to the national electric power supply grid. In the world we now live in, substation security and surveillance have become major concerns on a global scale for electric power utilities and providers. The economic and life safety consequences of deliberate and maliciously incurred power outages are obvious. The threat potential for these unattended and frequently remotely located and easily targeted facilities (which also includes remotely located wind farm and photovoltaic array/solar power generation sites) is considered to be high, and of critical national importance. Physical security protection of this enormous critical asset is clearly required, in terms of CCTV video surveillance, event recording, perimeter detection and monitoring, and controlled access to the site for maintenance and other authorized personnel, particularly at the points of power generation and at electrical transmission and distribution substations. As the threat potential to the national power supply grid is considered to be so significant, to ensure the maintenance of physical security at electrical substations, in March of 2014, the Federal Energy Regulatory Commission (FERC) mandated the North American Energy Reliability Corporation (NERC) to create a series of Critical Infrastructure Standards (CIP) that would define physical security risks and vulnerabilities related to the reliable operation of the bulk power supply system. NERC is a not-for-profit regulatory authority whose mission is to ensure the reliability of the electrical power system in North America, and it is subject to oversight by the FERC and governmental authorities in the U.S. and Canada. NERC s jurisdiction includes owners, operators, and users of the bulk power system which serves more than 334 million people. FERC had approved the NERCs critical infrastructure protection standard for physical security protection on November 20th, 2014; this standard is defined as NERC-CIP-014. With the advent of NERC-CIP-014, electrical utilities and bulk power providers have entered into an era that was basically unthinkable prior to the events at the PG & E Metcalf substation. NERC-CIP-014 requires that all power utilities in the U.S. and Canada comply with the security requirements defined by NERC by a given deadline, or they will be liable for sizeable fines. As such, the power utilities in these countries are under intense pressure to meet the difficult security regulations imposed by NERC-CIP
3 UNDERSTANDING NERC-CIP-014 NERC-CIP-014 is intended as a model, or best practices blueprint for the guidance of not only bulk electric power providers/utilities, but also for physical security professionals to provide the most effective protection of vital outdoor-located electrical transmission and distribution assets. NERC-CIP-014 was largely created as a guideline for the protection of North American electric power substations from physical attack. NERC-CIP-14 describes a systems approach for providing physical security protection of mission-critical substation facilities and other key assets within a utility, and six specific actions have been identified by NERC: -Deter -Detect -Delay -Assess -Communicate -Respond NERC also recommends a defense in depth concept to prevent the advance of an attacker. This concept entails the creation of several zones of protection over a wide area, so that the utility may respond to an event over a wider time interval, instead of utilizing a single, strong defensive line. These zones or layers of protection would typically initiate with the fencing surrounding the substation or other mission-critical facility, as well as controlled access points for authorized personnel, and ultimately terminate at some very critical location, such as the shelter containing the control and metering equipment at the substation. As part of the NERC-CIP-014 implementation process, each utility must identify their most mission-critical facilities; these are facilities defined as installations that in the event they were damaged or taken off-line, would result in widespread instability, uncontrolled separation or cascading within an interconnection. As a means of preventing such an event, the utility must develop, validate and implement plans to protect against physical attacks that may compromise the operability or recovery of these critical assets. To demonstrate compliance, a utility is required to perform a complete security audit and review, so as to identify any potential threats to the substations and other assets they have determined to be mission critical, confirm the risk assessment with an independent third party, and finally implement the physical security protection necessary to maintain protection of those assets. The utility is then required to submit to another independent third party analysis, to review and evaluate their intended means of providing compliance against the identified threats. These requirements are time-phased, allowing the utility the opportunity to install and integrate the required physical security detection and protection hardware within their facilities. As the threat potential by terrorist activity to disrupt the delivery of electric power will most likely remain for the foreseeable future, other issues such the theft of valuable equipment assets and vandalism are perhaps more well-known, and must also be considered from a security standpoint. With the price of copper at record levels, and as the use of copper is so prevalent within electrical substations, it has become a very attractive target for theft, often with lethal consequences for the thieves. Maintenance personnel have been injured, and in some cases killed when servicing facilities where electrical components where removed by theft, thereby compromising the safety of the installation when the theft was not detected previously by the utility. The mitigation approaches and processes that may be employed for NERC-CIP-014 compliance are beyond the scope of this paper, much of which utilizes proven and well-known hardware and mitigation techniques widely available within the industrial security marketplace. NERC-CIP-5 2 NERC has also released another highly important security standard; NERC-CIP-5. Although NERC-CIP-014 is largely concerned with the threat of physical security attacks compromising the integrity of the national power supply grid, NERC-CIP-5 addresses the equally serious threat of cyber-security attacks to the entire North American electrical power supply infrastructure.
4 COMMUNICATIONS EQUIPMENT FOR SUBSTATION PHYSICAL SECURITY & SCADA NETWORK APPLICATIONS The communication networks within the typical substation can be broken down into two key groups; the SCADA (Supervisory Control and Data Acquisition) subsystem, utilized for interconnecting all of the substation IEDs (Intelligent Electrical Devices) and RTUs (Remote Terminal Units), such as metering, control, and protective relaying equipment onto a common communications network; and the physical security subsystem, consisting of CCTV video for surveillance, perimeter detection and monitoring, and access control, for supporting the security requirements at the site. Substations are unique in that the environment where the electronic equipment is installed is extremely harsh, with severe voltage transients from circuit breakers and other switchgear, and high levels of EMI (electromagnetic interference) emanating from large power transformers and other high-voltage equipment. As the communications equipment for the SCADA and security sub-systems is usually located in an unconditioned shelter, or outdoors within weatherproof enclosures, it is exposed to a very wide range of operating temperature and humidity with condensation conditions. In this severe environment, ruggedized fiber optic transmission equipment is widely used, largely due to its inherent immunity to intense levels of electrical interference. Substation-rated managed layer 2 Ethernet switches and layer 3 routers with SCADA firewalls employing integral cellular radio modems have been recently introduced for providing highly secure and reliable communications circuits internal and external to the substation. These devices are particularly useful where the cost of installing a dedicated fiber optic network may be prohibitive, or where right-of-way issues may exist. License-free industrial-grade/out-of-plant-rated 5 Ghz wireless radio equipment is also widely deployed within substations, primarily for hauling IP video from the camera to the network backbone. These radios are ideal for this application, as they are simple to install, and do not require the costly installation of a dedicated fiber optic cable (and the attendant media converters) to provide this link. Although copper media-based CAT-5E/UTP and coaxial cable Ethernet extenders are available and widely used for many physical security related applications, they are not usually employed for substation security systems, due to their relative lack of EMI rejection in these electrically noisy environments, as well as their susceptibility to ground loops due to potential voltage difference issues. SUBSTATION-RATED COMMUNICATIONS EQUIPMENT: THE IEC STANDARD To maintain high levels of reliability, the communications equipment within the substation must be capable of surviving long-term in this kind of adverse operating environment, and with no degradation to performance or reliability. Two key and universally employed industry standards define the environmental requirements for all communications equipment fielded within an electrical substation: IEC for Ethernet-compatible communications equipment, and IEEE 1613 for legacy non-ethernet equipment. Equipment meeting these requirements is referred to as being substation-rated. Recognizing the growing demand for fiber optic transmission equipment capable of meeting these requirements, ComNet recently introduced their Reliance product line of substation-rated managed Ethernet layer 2 switches, layer 3 routers, media converters, and fiber optic serial data modems. These IEC and IEEE 1613 tested and certified products are widely used for substation SCADA networks, and for optically isolating electrically-delicate CCTV video cameras and other equipment related to the physical security protection subsystem from the harmful effects of EMI and high-voltage transients present within the substation. Managed layer 2 Ethernet switches are used for creating VLANs within the SCADA network, the security and surveillance subsystem, and any other communications requirements, such as VOIP telephony, etc. Layer 3 routers are employed for supporting the SCADA security firewalls required for NERC-CIP-5 compliance against cyber-security attacks, and for interconnecting numerous substations and other utility facilities via a high-speed, wide-area optical backbone. 3
5 Unlike nearly all traditional industrial security applications, the operating power within the substation is of poor quality, with substantial electrical noise and voltage transients, and it is usually not the commonly available 120/240 VAC, but rather -48 VDC, or high-voltage AC/DC at VDC or VAC. The 88 to 300 VDC power is derived from large storage battery banks that provide back-up operating power for all of the SCADA system control, metering, and protection equipment within the substation in the event of a localized power outage. ComNet Reliance-series equipment is designed to operate over any of these input power ranges. Specialized substation-rated/iec compliant thermal imaging IP CCTV cameras are now available not only for video surveillance and perimeter detection and monitoring purposes, but for remotely monitoring the operating temperature (and possible over-temperature/electrical overload condition) of large padmounted power transformers within the facility. Cameras for this application are typically integrated to the substation SCADA network. With the advent of modern IP video cameras and Ethernet-based access control equipment, it now becomes practical to easily integrate the physical security subsystem to the existing substation Ethernet SCADA network, with all of the equipment sharing a common, open standards-based Ethernet communications platform. IEC COMPLIANCE FOR PHYSICAL SECURITY SUBSYSTEM COMMUNICATIONS EQUIPMENT: YES OR NO? Any communications equipment utilized as part of the Ethernet-based substation SCADA system is invariably required to provide IEC compliance, due to the mission criticality of this application. As such, equipment located within the fence is usually specified by the utility to this standard. Equipment compliant with IEC is electrically, mechanically, and thermally very robust, and is designed to provide extremely high levels of reliability within the difficult substation environment. However, this comes at a cost; substationrated communications equipment is available from a relatively limited number of suppliers, and the cost of the equipment is significantly higher when compared to non-substation rated industrial-grade hardware. But will the fiber optic or wireless microwave radio communications equipment supporting the physical security subsystem benefit from IEC compliance? This is really a judgement call; many utilities and physical security system design engineers and systems integrators associated with the implementation of NERC-CIP-014 are of the opinion that it will not. Although the reliability enhancement derived from IEC compliant hardware can only serve to increase the reliability of the overall network, on a cost-benefit basis it may not be considered worth the additional cost of the equipment. Standard industrial-grade communications equipment rated for deployment in unconditioned out-of-plant environments, and with an operating temperature range of -40 to +75 degrees C, is generally considered as being sufficient for the physical security communications infrastructure within the typical substation. It is important to note that IEC /substation-rated Ethernet communications equipment may be seamlessly electrically and optically integrated with non-substation rated Ethernet communications equipment. As the SCADA network within the substation is almost always interconnected to a remotely located control and monitoring facility, the subsystem supporting the physical security requirements at the substation generally shares and makes effective use of the SCADA network platform. 4
6 CASE STUDY: A TYPICAL SUBSTATION PHYSICAL SECURITY COMMUNICATIONS EQUIPMENT SUBSYSTEM A major utility in the southeastern part of the U.S. is in the process of implementing a series of standardized physical security monitoring and detection subsystems for NERC-CIP-014 compliance at numerous substations within their wide-area transmission and distribution system. Several of these substations support a transmission voltage of 345 KV. The basic criteria and salient requirements for the physical security subsystem were as follows: Seamless integration of the physical security subsystem with the existing/legacy Ethernet-based substation SCADA network/platform Utilize newly installed IP video thermal imaging and conventional IP CCTV cameras Utilize legacy high-resolution analog CCTV cameras with a separate serial data pan-tilt-zoom control channel Install an IP-based access control system for the admittance of authorized maintenance staff to the site Provide IP-based electronic surveillance and detection around the entire substation facility perimeter Utilize fiber optic transmission equipment wherever possible for the physical security subsystem, to eliminate the possibility of electrical interference/emi and ground loops due to radiated and conducted emissions emanating from high-voltage power transformers, circuit breakers, switchgear, and other hightension equipment within the substation Employ license-free 5 Ghz microwave radio links for those CCTV IP video camera links where the cost or difficulty of installing new fiber optic cable may be prohibitive. Create separate VLANs for the CCTV video, the access control system, and the perimeter surveillance equipment, and any other equipment that is ancillary to the substation SCADA network Provide an NVR (Network Video Recorder) for storing/archiving the video from the facility The Ethernet-based SCADA network system at many of these substations employ a combination of legacy 10/100 and 100/1000 Mbps substation-rated/iec compliant managed layer 2 switches. Many of these switches provide a copper-only interface for the Ethernet data, with only the uplink ports supporting a fiber optic interface with fixed single-mode optics. Several of the newer-generation switches within some of the sites provide a combination of both copper and optical interfaces for the Ethernet data, with the optical ports SFP-based (Small Form Factor Pluggable), for greater flexibility in terms of user-selection of optical fiber compatibility, and optical transmission distance/path loss. The thermal imaging and conventional IP video cameras are PoE powered, and derive their +48 VDC operating power from industrial-grade (not substation-rated) shelf-mounted media converters. For those managed switches where an optical Ethernet interface is not available, the outputs of multi-channel media converters are connected directly to the copper ports of these switches. These media converters are co-located with the switches utilized for the SCADA network within the equipment shelter of the substation, and are rack-mounted for optimum use of the available 19-inch equipment rack real estate. The multi-channel media converters provide maximum channel count and density within each rack-mounted card-cage chassis. Where the managed switches provide an optical Ethernet interface, the media converters located at the fieldend or edge of the network are optically connected directly to the Ethernet optical input ports of the switch, eliminating the need for media converters at the switch-end of the link, thereby simplifying the design and enhancing the overall reliability of the system. 5
7 The legacy analog CCTV cameras utilize industrial-grade/out-of-plant-rated video encoder units. These shelfmount encoders are located at the camera-end of each of these links, and convert the baseband video analog output of the camera and the pan-tilt-zoom RS-232 serial control data to an Ethernet data stream utilizing highquality H.264/MPEG-4 video compression. The frame refresh rate is user-selectable, and may be remotely scaled at any rate from 1 FPS (Frames Per Second), to full-motion 30 FPS. The Ethernet output of the encoder is connected to a shelf-mount industrial-grade media converter, and the media converter at the other end of the link is connected to a copper port on one of the SCADA system managed switches. The video encoder and mating media converter are installed within a small unconditioned weatherproof NEMA enclosure. Software decoding is utilized for remote viewing of the video at the monitoring location of the network, thereby eliminating the need (and related cost) for hardware video decoders. For those newly installed IP video CCTV cameras where it was not considered practical to run new fiber optic cable to these camera locations, industrial-grade/out-of-plant-rated license-free 5 Ghz microwave radio links were installed in a point-to-point architecture for hauling the video from the camera to the substation equipment shelter. These radio links provide the +48 VDC PoE operating power to each camera unit, and the IP video received by the radio at the shelter-located end of the link is also fed into a copper Ethernet port of a substation SCADA system managed switch. The access control, and perimeter detection and surveillance systems also provide an Ethernet interface, and this equipment is optically connected to the substation SCADA network using the same approach as the CCTV IP video system described above. The final result was a highly reliable, easy to install and commission, and cost-effective physical security communications subsystem that made use of both legacy and newly installed equipment. The use of industrialgrade (not the more costly substation-rated/iec compliant) fiber optic and license-free microwave radio links provided complete immunity from any radiated or conducted EMI, and eliminated the possibility of any troublesome ground loops, even when the equipment was installed within the near-field of 345 KV highvoltage equipment. 6
8 TYPICAL SYSTEM ARCHITECTURE Typical System Architecture Two Electrical Substations with Integrated SCADA Network & Physical Security Two Electrical Substations with Integrated Subsystem Including SCADA IP Video Network CCTV Surveillance & Physical & Controlled Access Security Card Readers Subsystem Including IP Video CCTV Surveillance & Controlled Access Card Readers IED PoE Media Converter IP Camera Protective Relaying Synchrophasor Concentrator RTU SCADA Gateway Substation HMI Substation 1 Protective Relaying Ethernet Switch Ethernet Switch Media Converter Card Access Reader Backbone Switch 1 GBPS or 10 GBPS Backbone Switch Backbone Switch Router/Firewall Router/Firewall Server Utility Control Center Video Storage Server Network DVR Router/Firewall Ethernet Switch Ethernet Switch Media Converter Card Access Reader Protective Relaying Substation 2 Protective Relaying Synchrophasor Concentrator RTU SCADA Gateway Substation HMI IED PoE Media Converter IP Camera SUMMARY The use of substation-rated fiber optic Ethernet transmission equipment, such as media converters, managed Ethernet layer 2 switches for interconnecting the various SCADA system elements within the substation; and 1 gigabit or 10 gigabit layer 2 switches and layer 3 routers with a SCADA firewall for use as a high-speed optical backbone for connecting multiple substations to a common network, provides the user with the potential for significant scalability for their substation SCADA system for future expansion, and a reliable, secure network terminating at the utility s control and monitoring center. Managed layer 2 switches, and layer 3 routers with a SCADA firewall and integral cellular radio modem, can provide a highly cost-effective solution at the edge of the network, where the cost of installing fiber optic communications circuits may be difficult or cost-prohibitive, or where right-of-way issues may exist. All of this equipment will be found to be of considerable value when designing a substation SCADA system for NERC-CIP-5 compliance, or a physical security subsystem for NERC- CIP-014 compliance. Standard industrial-grade versions of this transmission equipment can provide a highly cost-effective solution with all of the benefits described above for the substation physical security subsystem for NERC-CIP-014 compliance, where the user is of the opinion that they may not require the technical benefits or wish to incur the cost penalties associated with IEC substation-rated hardware. 7
9 ComNet offers an extensive line of environmentally hardened fiber optic, copper-based, and wireless transmission and networking equipment that is designed to meet the unique requirements of the industrial security, intelligent transportation, industrial control, and the electric power, transmission, and distribution markets. Bruce Berman is responsible for directing and promoting the application of ComNet products to markets that can benefit from their use. In many cases he educates System Designers and customers on all levels about the benefits that ComNet products and technology bring to their projects. 3 CORPORATE DRIVE DANBURY, CT USA T: F: TECH SUPPORT: [email protected] 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS, UK LS27 7LE T: +44 (0) F: +44 (0) [email protected] 2015 Communication Networks. All Rights Reserved. ComNet and the ComNet Logo are registered trademarks of Communication Networks.
EoVDSL: A Cost-Effective Solution for Transmitting Ethernet Data Over Existing Copper Wiring for ITS and Traffi c Applications
WHITE PAPER: Eo: A Cost-Effective Solution for Transmitting Ethernet Data Over Existing Copper Wiring for ITS and Traffi c Applications By Bruce M. Berman ComNet Vice President of New Business Development
Ethernet over Copper Transmission Extenders
Ethernet over Copper Transmission Extenders Ethernet Transmission over Existing Coaxial or Cat5 Cable CopperLine is an advanced and unique technology that extends Ethernet networks beyond the 100 meter
Fiber s Role in the Video Security & Surveillance Network. Curt Carlson Product Manager Transition Networks
Fiber s Role in the Video Security & Surveillance Network Curt Carlson Product Manager Transition Networks Video technology overview Typical video network architecture Limitations of copper-based cabling
INTEGRATING SUBSTATION IT AND OT DEVICE ACCESS AND MANAGEMENT
Utilities WHITE PAPER May 2013 INTEGRATING SUBSTATION IT AND OT DEVICE ACCESS AND MANAGEMENT Table of Contents Introduction...3 Problem Statement...4 Solution Requirements...5 Components of an Integrated
Ethernet over Copper Transmission Extenders. Ethernet Transmission over Coaxial or UTP Cable. Fiber Optic and Ethernet Network Solutions
Ethernet over Copper Transmission Extenders Ethernet Transmission over Coaxial or UTP Cable Fiber Optic and Ethernet Network Solutions Ethernet over Copper CopperLine is an advanced and unique technology
Product Scope. Hardened Ethernet. Commercial Ethernet. Extended Ethernet. Wireless Ethernet. Fibre Optic Twisted Pair Coaxial Telephone Wireless
Product Review Product Scope Hardened Ethernet Commercial Ethernet Extended Ethernet Wireless Ethernet Fibre Optic Fibre Optic Twisted Pair Coaxial Telephone Wireless Where do we work? Unconditioned Environments
Media Conversion in Video Security and Surveillance Systems
The Conversion Technology Experts Media Conversion in Video Security and Surveillance Systems Worldwide Headquarters 6475 City West Parkway Eden Prairie, MN 55344 USA tel 952.941.7600 toll free 800.526.9267
Security Solutions to Meet NERC-CIP Requirements. Kevin Staggs, Honeywell Process Solutions
Kevin Staggs, Honeywell Process Solutions Table of Contents Introduction...3 Nerc Standards and Implications...3 How to Meet the New Requirements...4 Protecting Your System...4 Cyber Security...5 A Sample
Homeland Security Solutions
Homeland Security Solutions Homeland Security - RAD Solutions Many organizations in the public and private sectors today require Homeland Security (HLS) systems: Defense agencies and defense industries,
THE FUTURE OF SMART GRID COMMUNICATIONS
THE FUTURE OF SMART GRID COMMUNICATIONS KENNETH C. BUDKA CTO STRATEGIC INDUSTRIES MAY 2014 THE GRID OF THE FUTURE WIDE-SCALE DEPLOYMENT OF RENEWABLES INCREASED ENERGY EFFICIENCY PEAK POWER REDUCTION, DEMAND
How To Create An Intelligent Infrastructure Solution
SYSTIMAX Solutions Intelligent Infrastructure & Security Using an Internet Protocol Architecture for Security Applications White Paper July 2009 www.commscope.com Contents I. Intelligent Building Infrastructure
Your single source for network transmission solutions.
Transmission Network Solutions Safety Security Certainty Your single source for network transmission solutions. Robust performance and complete flexibility to meet all your current and future transmission
Going Critical. How to Design Advanced Security Networks for the Nation s Infrastructure. w w w. G a r r e t t C o m. C o m
Going Critical How to Design Advanced Security Networks for the Nation s Infrastructure Going Critical: Networks for Physical Security Increasing concerns and market growth Asset protection Public safety
IP Video Surveillance
IP Video Surveillance Solutions and Services Wireless IP PDA Administration Wireless Access Point Viewer Remote Control IP Video Server IP Network Alarm Management Video Recording Analog Video Server Access
Using Cellular RTU Technology for Remote Monitoring and Control in Pipeline and Well Applications
Using Cellular RTU Technology for Remote Monitoring and Control in Pipeline and Well Applications Steve Frank Business Development Manager Moxa Inc. Introduction Cellular technology minimizes site visits
Security Enhancements through Industrial Wireless Networking. Prepared by Microwave Data Systems Rochester, New York June 2002
Security Enhancements through Industrial Wireless Networking Prepared by Microwave Data Systems Rochester, New York June 2002 Introduction Although physical security has long been a concern at utilities,
RuggedCom Solutions for
RuggedCom Solutions for NERC CIP Compliance Rev 20080401 Copyright RuggedCom Inc. 1 RuggedCom Solutions Hardware Ethernet Switches Routers Serial Server Media Converters Wireless Embedded Software Application
John M Shaw Presentation to UTC Region 7 February 19, 2009 [email protected]
NERC CIP Substation Cyber Security Update John M Shaw Presentation to UTC Region 7 February 19, 2009 [email protected] It s February 19, 2009 132 project days left to compliance Do you know where (what)
Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches
ComNet Fiber Optic and Ethernet Transmission Equipment is setting the standard for value and performance. ComNet is a major provider of video, audio and data transmission, and network communication solutions
NERC CIP Substation Cyber Security Update. John M Shaw Presentation to UTC Region 7 February 19, 2009 [email protected]
NERC CIP Substation Cyber Security Update John M Shaw Presentation to UTC Region 7 February 19, 2009 [email protected] It s February 19, 2009 132 project days left to compliance Do you know where (what)
Power over Ethernet technology for industrial Ethernet networks
Power over Ethernet technology for industrial Ethernet networks Introduction Ethernet networking has grown beyond office and home usage to become a very successful protocol suite used in many industrial
Cisco Aironet 1520 Series Lightweight Outdoor Access Points
. Data Sheet Cisco Aironet 1520 Series Lightweight Outdoor Access Points Outdoor Access Points Flexible, Secure Mesh Platform for Demanding Environments Self-configuring and self-healing mesh in response
The Advantages of an Integrated Factory Acceptance Test in an ICS Environment
The Advantages of an Integrated Factory Acceptance Test in an ICS Environment By Jerome Farquharson, Critical Infrastructure and Compliance Practice Manager, and Alexandra Wiesehan, Cyber Security Analyst,
TCP/IP Network Communication in Physical Access Control
TCP/IP Network Communication in Physical Access Control The way it's done: The security industry has adopted many standards over time which have gone on to prove as solid foundations for product development
White paper. Video encoders - brings the benefits of IP surveillance to analog systems
White paper Video encoders - brings the benefits of IP surveillance to analog systems Table of contents 1. The easy path to network video 3 1.1 Technology shift 3 1.2 Gaining advanced and important functionalities
Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter
Industrial 10/100/BASE-T to 100/BASE-X SFP Media Converter Physical Port 1-port 10/100/BASE-T RJ45 with auto MDI / MDI-X function 1 SFP interface, 100/BASE-X dual mode (auto detection) Layer 2 Features
How to Integrate NERC s Requirements in an Ongoing Automation and Integration Project Framework
How to Integrate NERC s Requirements in an Ongoing Automation and Integration Project Framework Jacques Benoit, Cooper Power Systems Inc., Energy Automations Solutions - Cybectec Robert O Reilly, Cooper
c o m m u n i c a t i o n n e t w o r k s
c o m m u n i c a t i o n n e t w o r k s Founded in 2007, by George Lichtblau Former founder and owner of IFS. Majority of ComNet employees came from IFS. Massive industry experience. Same faces. New
How Proactive Business Continuity Can Protect and Grow Your Business. A CenturyLink White Paper
How Proactive Business Continuity Can Protect and Grow Your Business For most companies, business continuity planning is instantly equated with disaster recovery the reactive ability of a business to continue
Security & Surveillance
Security & Surveillance IP surveillance is a technology that has become pivotal in security, safety and process monitoring applications. Using the flexibility and scalability of sending video over TCP/IP,
Wireless Remote Video Monitoring
February 2010 Page 1 An Emerson Smart Solution brings visual information into your control room. Increase Plant Safety Comply with Regulations Scalable Reduced Cost Secure and Reliable Communications Full
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
8-Port 10/100Mbps 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch
8-Port 10/100Mbps 802.3at + 1-Port 10/100/1000Mbps Desktop Switch Key Features RJ-45 Interface 8-Port 10/100Mbps Fast Ethernet Switch 8-Port supports 56V DC power to powered device 1-Port 10/100/1000Mbps
ComNet T-1/E-1 Optical Transceiver/ Extender Units
ComNet New Product Release: ComNet T-1/E-1 Optical Transceiver/ Extender Units By Bruce M. Berman ComNet Vice President of New Business Development ComNet T-1/E-1 Optical Transceiver/Extender Units ComNet
4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature
4-Port 10/Mbps with + 1-Port FX Industrial Ethernet Switch Wide Temperature 15 F Fiber Optic Link Capability for Flexible Distance Extension The series equips one Base-FX port that provides more flexibility
INTRODUCTION TO MEDIA CONVERSION
WHITE PAPER INTRODUCTION TO MEDIA CONVERSION Table of Contents Introduction 1 What is a Media Converter? 1 Advantages of Media Conversion Technology 1 Benefits of Fiber Optic Cabling 2 Types of Media Converters
Wireless Remote Video Monitoring
October 2014 Page 1 An Emerson Smart Solution brings visual information into your control room. Increase plant safety Comply with regulations Scalable Reduced cost Secure and reliable communications Full
NERC Cyber Security Standards
SANS January, 2008 Stan Johnson Manager of Situation Awareness and Infrastructure Security [email protected] 609-452-8060 Agenda History and Status of Applicable Entities Definitions High Level of
Systems Integration Track: Network Topology
Systems Integration Track: Network Topology Author Jim W. Hammond Technical Consultant, GarrettCom Keywords: Ring, Topology, RSTP, Ethernet, Network, VLAN Industrial networks, like most large networks,
ICON INTEGRATED COMMUNICATIONS OPTICAL NETWORK
ICON INTEGRATED COMMUNICATIONS OPTICAL NETWORK DEPENDABLE COMMUNICATIONS FOR CRITICAL INFRASTRUCTURE 2 Dependable communications are essential for the safe and reliable operation of critical infrastructure.
How To Build A Network For Mining
GE Digital Energy Industrial Communication Solutions for the Mining Industry g imagination at work GE Industrial Communications For over twenty-five years, GE Industrial Communications has provided rugged
Transporting Legacy Switched Digital Circuits Using a Packet Network
Transporting Legacy Switched Digital Circuits Using a Packet Network Engage Communication is the manufacturer of high-speed data communications products, specifically targeting the growing market for converting
Video Architectures Eyes on the Future: The Benefits of Wireless Technology for Fixed Video Surveillance
S O L U T I O N PA P E R Video Architectures Eyes on the Future: The Benefits of Wireless Technology for Fixed Video Surveillance Table of Contents Fixed Video Surveillance: The Big Three... 3 Wireless
Solution Overview. Smarter Video Surveillance with NETGEAR
Smarter Video Surveillance with NETGEAR A b s t r a c t a n d A u d i e n c e NETGEAR Solution Overviews provide high-level solutions to common business IT challenges for end users, Value-Added Resellers
Axis network cameras A wide portfolio of products for professional video surveillance.
Axis network cameras A wide portfolio of products for professional video surveillance. The market s widest range of network cameras The video surveillance market is thriving, driven by increased public
The Cisco and Pelco Industrial Wireless Video Surveillance Solution: Real-Time Monitoring of Process Environments for Safety and Security
The Cisco and Pelco Industrial Wireless Video Surveillance Solution: Real-Time Monitoring of Process Environments for Safety and Security The Cisco and Pelco Industrial Wireless Video Surveillance Solution
Cisco Advanced Services for Network Security
Data Sheet Cisco Advanced Services for Network Security IP Communications networking the convergence of data, voice, and video onto a single network offers opportunities for reducing communication costs
www.quicknetworksolutions.net RC: 960240
QSL is a growing business that s offering IT Solutions and services to SME and Established Organizations with a high level of understanding and fully qualified, friendly and knowledgeable consultants.
Real Time Remote Monitoring over Cellular Networks. Wayne Chen Marketing Specialist
Real Time Remote Monitoring over Cellular Networks Wayne Chen Marketing Specialist Introduction For distribution infrastructures located in remote, isolated areas, unmanned monitoring systems have long
Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: US-24-250W, US-24-500W, US-48-500W, US-48-750W
Managed PoE+ Gigabit es with SFP Models: US-24-25W, US-24-5W, US-48-5W, US-48-75W Non-Blocking Throughput ing Performance Gigabit Ethernet RJ45 and SFP+/SFP Ports Auto-Sensing IEEE 82.3af/at PoE Build
IP Camera Network Installations are More Difficult than Analog Camera Installations? Not So!
November 2010 IP Camera Network Installations are More Difficult than Analog Camera Installations? Not So! Here Are The Facts. White Paper Table of Contents: Page 1 Overview A Brief History Page 2 A Big
Introduction. Industry Changes
Introduction The Electronic Safety and Security Design Reference Manual (ESSDRM) is designed to educate and inform professionals in the safety and security arena. The ESSDRM discusses trends and expertise
How Much Cyber Security is Enough?
How Much Cyber Security is Enough? Business Drivers of Cyber Security Common Challenges and Vulnerabilities Cyber Security Maturity Model Cyber Security Assessments September 30, 2010 Business in the Right
Bosch IP An introduction to IP technology and the future of CCTV. Bosch IP Network Video Product Guide
Bosch IP An introduction to IP technology and the future of CCTV Bosch IP Network Video Product Guide 2 3 Changes in CCTV technology have been driven by three main requirements. The first is the need to
Cyber Threats in Physical Security Understanding and Mitigating the Risk
Cyber Threats in Physical Security Understanding and Mitigating the Risk Synopsis Over the last few years, many industrial control systems, including security solutions, have adopted digital technology.
FIBRE TO THE BTS IMPROVING NETWORK FLEXIBILITY & ENERGY EFFICIENCY
FIBRE TO THE BTS IMPROVING NETWORK FLEXIBILITY & ENERGY EFFICIENCY (Study Paper by FLA Division) Ram Krishna Dy. Director General (FLA) TEC New Delhi, DoT, Govt. of India. E-mail: [email protected] Mrs.
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
MPLS: Key Factors to Consider When Selecting Your MPLS Provider Whitepaper
MPLS: Key Factors to Consider When Selecting Your MPLS Provider Whitepaper 2006-20011 EarthLink Business Page 1 EXECUTIVE SUMMARY Multiprotocol Label Switching (MPLS), once the sole domain of major corporations
Power over Ethernet Solutions for Campus Environments. White Paper
Power over Ethernet Solutions for Campus Environments White Paper October 2011 Campus Networks Today s campus environments experience constant growth and improvements in technology to provide students
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet Today s network managers know that modern demands on a network by its users can shrink bandwidth dramatically. Faster computers,
Chapter 1: roadmap. Access networks and physical media
Chapter 1: roadmap 1.1 What is the nternet? 1.2 Network edge 1.3 Network core 1.4 Network access and physical media 1.5 nternet structure and SPs 1.6 elay & loss in packet-switched networks 1.7 Protocol
Auspex Support for Cisco Fast EtherChannel TM
Auspex Support for Cisco Fast EtherChannel TM Technical Report 21 Version 1.0 March 1998 Document 300-TC049, V1.0, 980310 Auspex Systems, Inc. 2300 Central Expressway Santa Clara, California 95050-2516
Leveraging the Industrial Internet of Things (IOT) to Optimize Renewable Energy
Leveraging the Industrial Internet of Things (IOT) to Optimize Renewable Energy Creating More Efficient and Connected Wind Turbines By: Brian Roth, Product Marketing Engineer February 1, 2016 Leveraging
How To Protect Video From Being Lost In A Fault Fault On A Network With A Shadow Archive
A MARCH NETWORKS WHITE PAPER Shadow Archiving in Video Surveillance Systems Fail Safe Recording Options for IP Edge Devices Table of Contents Executive Summary...2 Introduction...2 Background...2 DVR
SCADA Systems Automate Electrical Distribution
SCADA Systems Automate Electrical Distribution PC-based supervisory control and data acquisition systems increase uptime, cut costs and improve utilization. A White Paper from InduSoft Fabio Terezinho
John Ragan Director of Product Management. Billy Wise Communications Specialist
John Ragan Director of Product Management Billy Wise Communications Specialist Current Substation Communications Physical Infrastructure Twisted Pair, 4 Wire, COAX, Cat5 & Cat6, 9 Pin Serial Cable, Single-mode
- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).
Page 1 of 30 Page 2 of 30 1. Basic terminology - Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF). - Remote Element:
CONNECT PROTECT SECURE. Communication, Networking and Security Solutions for Defense
CONNECT PROTECT Communication, Networking and Security Solutions for Defense Engage Communication provides Defense, Homeland Security and Intelligence Communities with innovative and cost effective solutions
San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions August 10, 2015. Electric Grid Operations
San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions August 10, 2015 Electric Grid Operations Director Electric Grid Operations: Responsible for overall transmission
H.264 Internet Video Server
Key Features Video / Audio H.264 / MPEG-4 and M-JPEG video compression simultaneously Simultaneous multi-stream support Up to 30/25 (NTSC/PAL) fps for all profiles 3DNR (3D Noise Reduction) to improve
Securing Modern Substations With an Open Standard Network Security Solution. Kevin Leech Schweitzer Engineering Laboratories, Inc.
Securing Modern Substations With an Open Standard Network Security Solution Kevin Leech Schweitzer Engineering Laboratories, Inc. Copyright SEL 2009 What Makes a Cyberattack Unique? While the resources
4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Web Smart Switch
4-Port 10/Mbps with + 1-Port FX Industrial Web Smart Switch The PLANET series, a Web management Industrial Switch, is designed to transmit power and data over single Ethernet cable to remote capable devices
Communication Infrastructure Convergence & The need of IS Audit Compliance. Ninad M. Desai
Communication Infrastructure Convergence & The need of IS Audit Compliance. Ninad M. Desai RCDD CISA CFOT Consulting Specialist Communication Cabling. Auditor Information Systems & Technology. Convergence
Smart Solutions for Network IP Migration
for Network IP Migration Network Access Timing and Synchronization Test & Measurement Agenda: Architectures and Topologies Product life cycle Media and Protocol Conversion Application Cases Conclusion
Redundant Gigabit Backbone Adds Speed and Reliability to Industrial Networks
Adds Speed and Reliability to Industrial Networks by Harry Hsiao, MOXA Product Manager [email protected] Introduction Gigabit network applications are becoming more and more popular in the modern networking
San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions June 4, 2015. Electric Grid Operations
San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions June 4, 2015 Electric Grid Operations Director Electric Grid Operations: Responsible for overall transmission
1. Cyber Security. White Paper Data Communication in Substation Automation System (SAS) Cyber security in substation communication network
WP 1004HE Part 5 1. Cyber Security White Paper Data Communication in Substation Automation System (SAS) Cyber security in substation communication network Table of Contents 1. Cyber Security... 1 1.1 What
Chapter 4 Connecting to the Internet through an ISP
Chapter 4 Connecting to the Internet through an ISP 1. According to Cisco what two things are essential to gaining access to the internet? a. ISPs are essential to gaining access to the Internet. b. No
Chapter 1 Introduction
Chapter 1 Introduction Chapter 1 provides background information on electronic safety and secuirty (ESS), including the definition and areas of knowledge required for an ESS designer. Information contained
Management and Wireless in the Data Center
SOLUTIONS BRIEF Management and Wireless in the Data Center High Performance Wireless Networks Management and Wireless in the Data Center Worldwide demand for new and more powerful IT-based applications,
Increase Simplicity and Improve Reliability with VPLS on the MX Series Routers
SOLUTION BRIEF Enterprise Data Center Interconnectivity Increase Simplicity and Improve Reliability with VPLS on the Routers Challenge As enterprises improve business continuity by enabling resource allocation
SafeNet Network Encryption Solutions Safenet High-Speed Network Encryptors Combine the Highest Performance With the Easiest Integration and
SafeNet Network Encryption Solutions Safenet High-Speed Network Encryptors Combine the Highest Performance With the Easiest Integration and Management SafeNet Network Encryption and Isolation Solution
WHITEPAPER MPLS: Key Factors to Consider When Selecting Your MPLS Provider
WHITEPAPER MPLS: Key Factors to Consider When Selecting Your MPLS Provider INTRODUCTION Multiprotocol Label Switching (MPLS), once the sole domain of major corporations and telecom carriers, has gone mainstream
The President s Critical Infrastructure Protection Board. Office of Energy Assurance U.S. Department of Energy 202/ 287-1808
cover_comp_01 9/9/02 5:01 PM Page 1 For further information, please contact: The President s Critical Infrastructure Protection Board Office of Energy Assurance U.S. Department of Energy 202/ 287-1808
TSC (Total Solution Communications Ltd)
TSC (Total Solution Communications Ltd) 1 Parkway Drive, Mairangi Bay, North Harbour Phone: 09 477 2888 Fax: 09 477 2889 E-Mail: [email protected] Web: www.tsc.co.nz A vaya IP Office Converged Communications
Communication Networks. We are securing the past in a fast moving future. FOX605 multiservice platform.
Communication Networks We are securing the past in a fast moving future. FOX605 multiservice platform. FOX605 Overview Operational networks of utilities demand real-time communication across the complete
Whitepaper. IP Networking and Its Impact on Video Surveillance
Whitepaper IP Networking and Its Impact on Video Surveillance Introduction Video surveillance is critical for business. Different organizations use video surveillance to protect people s safety, protect
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F TABLE OF CONTENTS Appendix F - Electrical Engineering Design Criteria F.1 Introduction...F-1 F.2 Codes and Standards...F-1 F.3 Switchyard and Transformers...F-1
Crash Phone Solution. Communications. Command. Control
Communications Command Control Crash Phone Solution On September 11, 2001 the plane crash at the Pentagon required an immediate public safety response from over 10 different agencies, some with overlapping
Making the Case for Satellite: Ensuring Business Continuity and Beyond. July 2008
Making the Case for Satellite: Ensuring Business Continuity and Beyond July 2008 Ensuring Business Continuity and Beyond Ensuring business continuity is a major concern of any company in today s technology
Cisco EtherSwitch Network Modules
Cisco EtherSwitch Network Modules 16- and 36-Port 10/100 Ethernet Modules for Cisco 2600/2800/3600/3700/3800 Series Routers Figure 1. Cisco 16-Port and 36-Port EtherSwitch Network Modules The Cisco 16-