Journal of Physiology - Paris
|
|
|
- Colin Hubbard
- 10 years ago
- Views:
Transcription
1 Journal of Physiology - Paris 103 (2009) Contents lists available at ScienceDirect Journal of Physiology - Paris journal homepage: Improving the SNR of EEG generated by deep sources with weighted multielectrode leads Outi Väisänen *, Jaakko Malmivuo Department of Biomedical Engineering, Tampere University of Technology, P.O. Box 692, FIN Tampere, Finland article info abstract Keywords: Multielectrode EEG lead Lead field theory Sensitivity distribution Deep EEG sources Signal-to-noise ratio We have developed a multielectrode lead technique to improve the signal-to-noise ratio (SNR) of scalprecorded electroencephalography (EEG) signals generated deep in the brain. The basis of the method lies in optimization of the measurement sensitivity distribution of the multielectrode lead. We claim that two factors improve the SNR in a multielectrode lead: (1) the sensitivity distribution of a multielectrode lead is more specific in measuring signals generated deep in the brain and (2) spatial averaging of noise occurs when several electrodes are applied in the synthesis of a multielectrode lead. We showed theoretically that within a three-layer spherical head model the sensitivity distributions of multielectrode leads are more specific for deep sources than those of traditional bipolar leads. We also estimated with simulations and with preliminary measurements the total improvement in SNR achieved by both the more specific lead field and spatial averaging. Results obtained with simulations and with experimental measurements show an apparent improvement in SNR obtained with multielectrode leads. This encourages for future development of the method. Ó 2009 Elsevier Ltd. All rights reserved. 1. Introduction The electroencephalogram (EEG) is traditionally measured with either unipolar or bipolar leads from the surface of the scalp. These measurements are much more sensitive to cortical than to deep EEG sources (Malmivuo and Suihko, 2004). Modern EEG equipment, comprising up to 256 channels, enable the synthesis of new kinds of measurement leads. The purpose of this study is to develop new multielectrode EEG leads being more sensitive in detecting signals generated deep in the brain. This is important especially in evoked potential studies, where the generators of potentials measured are so located. Such generators include for example brainstem auditory evoked potentials (BAEP) (Chiappa and Hill, 1997). The traditional bipolar measurement set-up is relatively insensitive to such brainstem sources and thousands of epochs must thus be averaged to obtain a reasonable signalto-noise ratio (SNR). Great interest therefore attaches to the development of new measurement leads and methods which would promote better detection of signals generated deep in the brain. Most of the methods previously applied to improve the SNR of such measurements comprise different signal-processing techniques designed to reduce noise by means of various temporal averaging schemes. Such approaches include for example median and * Corresponding author. Tel.: ; fax: addresses: [email protected] (O. Väisänen), [email protected] (J. Malmivuo). weighted averaging and trimmed estimators (Davila and Mobin, 1992; Ozdamar and Kalayci, 1999; Leonowicz et al., 2005; Sörnmo and Laguna, 2005). Also wavelet-based denoising methods have been applied to improve the SNR (Causevic et al., 2005). Adaptive linearly constrained variance methods, so-called beamformers, have been applied to enhance e.g. deep epileptiform activity (Ward et al., 1999), although this approach is most often applied in solving inverse problems (van Drongelen et al., 1996; Van Veen et al., 1997). The beamformer methods resemble the present multielectrode lead approach, because both methods act as spatial filters i.e. they enhance signals generated in the target region. In this study we investigate a method which is based on optimizing the sensitivity distribution of a multielectrode lead for deep brainstem sources. The purpose is to introduce the method and to demonstrate the benefits of multielectrode leads compared to bipolar leads. Differences in sensitivity distributions are analyzed theoretically and the increase in SNR is estimated with simulations. We have also conducted a preliminary experimental measurement to validate the simulation results obtained on improved SNR (Väisänen and Malmivuo, 2007). 2. Methods 2.1. Lead field and reciprocity theorem We applied the lead field theory to calculate the measurement sensitivity distributions of different EEG leads (McFee and John /$ - see front matter Ó 2009 Elsevier Ltd. All rights reserved. doi: /j.jphysparis
2 O. Väisänen, J. Malmivuo / Journal of Physiology - Paris 103 (2009) ston, 1953). According to the reciprocity theorem, the lead field in the volume conductor can be calculated by feeding a unit reciprocal current I r to the lead (Malmivuo and Plonsey, 1995). The reciprocal current gives rise to a current density field J L in the volume conductor. This current density field is the lead field, which is the sensitivity distribution of the lead. Eq. (1) describes the relationship between the measured signal V L in the lead, the current sources J i and the lead field J L in the volume conductor, when a reciprocal current I r is applied to the lead (Malmivuo and Plonsey, 1995): V L ¼ 1 I r Z 1 r J L J i dv; where r is the conductivity at the source location in the volume conductor An ideal lead field Interest focused on signals generated in the brainstem, i.e. close to the center of the volume conductor. In this case all activity generated in other areas of the volume conductor, e.g. at the cortex, is regarded as noise. Within the brain volume the bipolar EEG lead has the highest sensitivity on the cortex (Malmivuo and Suihko, 2004). Its sensitivity distribution is thus not optimal for measuring signals generated in deeper structures. According to Eq. (1) an ideal sensitivity distribution for recording signals is such that its magnitude is concentrated at the source location and its orientation is parallel to the source orientation. To completely suppress the noise generated within the brain, the magnitude of the sensitivity distribution should be zero outside the source location. This is also the criterion for the optimal spatial filter in the beamformer methods (e.g. Eq. (12) in (Van Veen et al., 1997)). From the reciprocity theorem it is easy to understand, that this criterion can be closely achieved for superficial sources, because the sensitivity of closely separated electrodes is concentrated on the surface of the cortex. For the deep sources this criterion cannot be achieved. When the measurement electrodes are located on the surface of the scalp, at least within the spherical head models, it is impossible to obtain a sensitivity distribution where the magnitude is concentrated at the center of the brain. Instead we assume that the best sensitivity distribution realized for deep sources is the uniform sensitivity distribution within the brain volume. By uniform sensitivity distribution we mean that its magnitude and orientation are uniform throughout the source volume. The method for synthesizing a uniform lead field in a finite homogeneous volume conductor was introduced by Brody (1957), also described in Malmivuo and Plonsey (1995). The generation of such a lead field in the direction of the z-axis is illustrated in Fig. 1 (Malmivuo and Plonsey, 1995). In Fig. 1b an arbitrarily shaped finite homogeneous volume conductor is illustrated. In Fig. 1a it is extended in the direction of the z-axis to the cylinder which has the cross-section of the original volume conductor. The end planes of the cylinder are plated with a well-conducting material. As illustrated in Fig. 1a the extensions of the volume conductor are sliced to form isolated filaments. The slicing is done along the current flow lines, so that they are not intersected. If the resistors in Fig. 1b have the resistance equal to the corresponding volume conduction filaments outside the volume conductor in Fig. 1a, and the reciprocal current is applied through this resistor network, the lead field in the original volume conductor will be close to uniform. We call such a lead as illustrated in Fig. 1b as a multielectrode lead because both of its terminals are composed of several electrodes. In both terminals the electrodes are connected together through the resistor network. The more electrodes are placed on ð1þ the surface of the volume conductor, the more uniform the lead field is (Malmivuo and Plonsey, 1995). The synthesization of a uniform lead field within a homogeneous spherical model is next described. First we consider a cylindrical homogeneous volume conductor with circular cross-section. To synthesize a uniform lead field the injected reciprocal current at every electrode must be incrementally proportional to cos h, as illustrated in Fig. 2a(Malmivuo and Plonsey, 1995). h is the angular displacement of the electrode from the negative z-axis. The uniform lead field, which is indicated with grey arrows, will be oriented in the positive z-direction. The variable resistors indicate that the reciprocal current fed to electrodes is adjusted based on the angle h. As illustrated in Fig. 2b it may be assumed that the spherical model consists of thin cylindrical disks, which have a circular cross-section. Within each of the disks the uniform lead field in the positive z-direction can be obtained as illustrated in Fig. 2a. Also the shape of the volume conductor along the y-axis needs to be considered and the reciprocal current applied to electrodes at every thin disk must be incrementally proportional to cos u, where u is the angular displacement of the disk from the xz-plane. Thus, to obtain a uniform lead field throughout the spherical volume conductor, the reciprocal current injected at each electrode needs to be incrementally proportional to: I / cos h cos u ð2þ In the present study we sought to synthesize a uniform lead field within the brain volume in a three-layer spherical head model. Kettunen and Malmivuo have shown (unpublished results), that if reciprocal currents calculated with Eq. (2) are injected to an inhomogeneous spherical head model, the lead field will be uniform within the innermost sphere. In the case of a three-layer spherical head model, the brain volume is the innermost sphere. A significant benefit of a dense EEG array is that the multielectrode lead can be so oriented that the sensitivity distribution is parallel to the source orientation. The parallel orientation maximizes the signal amplitude according to Eq. (1) Synthesis of a multielectrode lead With modern digital signal processing there is no need to physically construct the resistor networks as illustrated in Figs. 1b and 2a to synthesize a multielectrode lead. Instead, the EEG can be measured as unipolar measurements with a dense EEG electrode array. The recorded signal of the multielectrode lead can be calculated either online during the measurement or offline thereafter, by adjusting the weight of each unipolar lead. The weights of different unipolar leads are obtained based on optimization of the sensitivity distribution with Eq. (2). The noise-contaminated signal x of the multielectrode lead can be calculated with: xðtþ ¼ XL i¼1 w i ½s i ðtþþn i ðtþš; where w i is the weight of unipolar lead i, s i is the signal measured with unipolar lead i, n i is the noise in unipolar lead i and L the number of unipolar leads from which the multielectrode lead is synthesized. When the multielectrode lead is synthesized from unipolar leads, the reference electrode used in the unipolar measurements will be included in either one of the terminals. Whether it is included in the positive or negative terminal depends on its location. The sensitivity distribution and thus the weights of a multielectrode lead can be optimized before the EEG measurement, if the electrode locations are known. This can be accomplished for example by using an electrode cap. Thus the sensitivity distribution ð3þ
3 308 O. Väisänen, J. Malmivuo / Journal of Physiology - Paris 103 (2009) when the original unipolar EEG data and the exact electrode coordinates have also been acquired Sensitivity distribution analysis Fig. 1. Generation of a uniform lead field in a finite homogeneous volume conductor in the direction of the z-axis. In (a) a finite homogeneous volume conductor is extended in the direction of the z-axis to the cylinder which has a cross-section of the original volume conductor in (b). The extensions of the volume conductor are sliced to form isolated filaments. The slicing is so done that the reciprocal current flow lines are not intersected, as illustrated in (a). If the resistors in (b) have a resistive value equal to the volume conduction filaments outside the volume conductor in (a), and the reciprocal current is applied through this resistor network, the lead field in the original volume conductor will be close to uniform. Figure modified from Malmivuo and Plonsey (1995). Fig. 2. Generation of a uniform lead field in a spherical volume conductor in the direction of z-axis. The spherical volume conductor can be approximated so as to be composed of thin cylindrical disks. In (a) a plot from the xz-plane is illustrated. Variable resistors reflect that the current applied to different leads is adjusted based on the angle h. The grey arrows outline the lead field. In (b) a plot from the xy-plane is illustrated. u is the angular displacement of the disk from the xz-plane. optimization does not prolong the time the patient is being prepared for the measurement or the EEG data is acquired. In some EEG acquisition programs there is a possibility to form new derived channels as linear combinations of unipolar measurement channels. The multielectrode lead can be synthesized in this manner as an additional channel and its signal can be recorded simultaneously with the unipolar channels. If the quality of a multielectrode lead signal acquired online is not sufficient, the multielectrode lead can be adjusted after the EEG measurement As a volume conductor model we applied the three-layer spherical head model with radii of 92 mm, 85 mm and 80 mm, respectively, as in Rush and Driscoll (1969) head model. As in (Oostendorp et al., 2000) the resistivity ratio between the tissues was 1:15:1. We applied the lead field and reciprocity theorems to calculate the sensitivity distributions within the brain volume. In the calculations we used the analytical equations derived by Rush and Driscoll (1969). The sensitivity distributions of different leads were compared with two new parameters, the region of interest sensitivity ratio (ROISR) and the coefficient of variation of the sensitivity outside the region of interest (nonroiscv), the former of which is introduced in Väisänen et al. (2008). The nonroi volume is the source volume outside the region of interest (ROI) i.e. the brain volume outside the ROI. The ROISR defines how much more sensitive on average the detector is to individual sources in the ROI than to individual sources outside it. ROISR ¼ S k S m ; where S k ¼ 1 K S m ¼ 1 M X K k¼1 X M m¼1 kj Lk k; kj Lm k: In (4) (6) S k is the average sensitivity within the ROI, k is the index of the lead vector location within the ROI, K is the total number of lead vectors calculated within ROI, S m is the average sensitivity within nonroi, m is the index of the lead vector within nonroi and M is the total number of lead vectors calculated within nonroi. kk is the L2-norm. According to Eq. (1), Eq. (4) is most suitable in cases where the sensitivity distribution is parallel to the source orientation. The ROISR defines how well the measurement sensitivity is concentrated within the ROI. When the sensitivity distribution is uniform, the value of the ROISR equals one. The nonroiscv parameter defines the degree of uniformity in the magnitude of the sensitivity within the source volume outside the ROI. It is defined as the ratio between the standard deviation of the sensitivity within nonroi and the average sensitivity in the same volume. nonroiscv ¼ r S m S m 100%; ð7þ where rffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi 1 X M r Sm ¼ M 1 ðkj m¼1 L m k S m Þ 2 : ð8þ In (7) S m is the average sensitivity within nonroi, and it is calculated with Eq. (6), r Sm is the standard deviation of the sensitivity within nonroi and it is calculated with Eq. (8). When the sensitivity distribution is uniform, the value of nonroiscv equals 0% Theoretical multielectrode leads We studied altogether four different theoretical leads: one bipolar and three multielectrode leads. In theoretical multielectrode lead analysis we assumed that the source is located parallel to the z-axis at the center of the brain. In the bipolar lead the angle ð4þ ð5þ ð6þ
4 O. Väisänen, J. Malmivuo / Journal of Physiology - Paris 103 (2009) between electrodes was 180 and the electrodes were placed on the z-axis (see Fig. 2 for the coordinate system). This lead is referred to as BL from here on. The three different multielectrode leads consisted of 58, 102 and 202 electrodes. From here on these leads are called ML58, ML102 and ML202, respectively. These multielectrode leads are called as theoretical, because the point electrodes were placed as uniformly as possible over the whole spherical scalp surface. In all three multielectrode leads we first calculated the lead fields of all 57, 101 and 201 unipolar leads. All unipolar leads had the same reference electrode location (0 cm, 0 cm, 9.2 cm). The weights w i of individual unipolar leads were calculated with Eq. (2) based on the measurement electrode location, so that the lead field of the synthesized multielectrode lead was oriented along the positive z-axis Preliminary experimental measurements and experimental multielectrode leads In addition to the analysis conducted with theoretical leads we analyzed such multielectrode leads, where the electrodes are realistically distributed on the scalp surface. From here on these leads are called as experimental multielectrode leads. The realistic electrode locations were obtained from preliminary experimental measurements. These measurements were conducted to validate the SNR improvement obtained with the multielectrode lead technique. We chose to measure BAEPs (Nuwer et al., 1994), which are generated in the auditory pathway passing through the cochlear nerve, pons and midbrain. The preliminary BAEP measurements were conducted in Väisänen and Malmivuo (2007). BAEPs were obtained from four volunteers (3 male, 1 female, mean age 28) with normal BAEP. As a stimulus we used a rarefaction click with a presentation frequency of 9.9 Hz. We stimulated the right and left ear of each testee in separate measurements, by delivering the click stimuli through a tubal phone to the ipsilateral ear, while a mask noise was presented to the contralateral ear. From each testee we collected 4000 epochs both per right ear stimulation and per left ear stimulation, resulting in two different datasets per testee. EEG was measured with a 124-channel EEG cap (SynAmps, NeuroScan, Compumedics). The measurement set-up included also the traditional BAEP electrodes placed at vertex (Cz), right mastoid and left mastoid. Depending on the stimulated ear, the mastoids are called as ipsilateral mastoid (Ai) or contralateral mastoid (Ac). The reference electrode was located on the forehead. The high-pass filter was set at 0.05 Hz and the low-pass at 2000 Hz. Subsequently and prior to the offline analysis the data were filtered with a 100 Hz high-pass filter. The time interval selected for the SNR analysis included BAEP peaks IV and V. The electrode coordinates for each testee were digitized with Polhemus FASTRAK. Before the calculation of the lead fields and the weights w i, the electrode positions were recentered, so that the locations best fitted the surface of the spherical head model (Delorme and Makeig, 2004). The electrodes having notably high contact impedance or signal looking extremely noisy were excluded from the multielectrode lead. The total number of electrodes in experimental multielectrode leads varied between 110 and 118, average being 114. Also artifact contaminated epochs were excluded from the analysis. The weights w i were calculated with Eq. (2) from the recentered electrode coordinates. In the synthesized experimental multielectrode leads the number of electrodes in the negative terminal exceeded the number of electrodes in the positive terminal, because the electrodes covered the upper part of the scalp more comprehensively than the lower part. The lead field orientation of the multielectrode lead was optimized by rotating the coordinate system. In the optimal lead, the sensitivity distribution is oriented parallel to the source orientation. Thus the lead field orientation giving the highest SNR was considered optimal. The optimization was done separately for each testee and for both simulated ear, resulting in the total of eight optimized experimental multielectrode leads. The signal of the multielectrode lead was calculated offline after the recording with Eq. (3). All the calculations were done in Matlab. EEGLAB was applied to read the Neuroscan files into the Matlab (Delorme and Makeig, 2004). To evaluate the improvement in SNR, we compared the SNR obtained with optimized experimental multielectrode lead to the SNR obtained with bipolar BAEP lead Cz Ai (Väisänen and Malmivuo, 2007). From the measured data the SNRs scaled for single epochs were calculated with equations adopted from Raz et al. (1988). Equations in Raz et al. (1988) estimate the power SNR, and we took the square root of the values to calculate amplitude SNRs. SNR was defined as the standard deviation of actual signal divided by the standard deviation of the noise signal Simulation study on spatial averaging in multielectrode leads In the synthesis of the multielectrode lead, in addition to the uniform sensitivity distribution being more sensitive to deep sources, we also assume that spatial averaging of noise further improves the SNR. We conducted a simulation study to evaluate the effect of spatial averaging. We simulated the brainstem evoked potentials by placing a dipolar source at the center of the brain at location (0 cm, 0 cm, 0 cm). The magnitude of the source dipole varied sinusoidally. The noise-contaminated signal of the multielectrode lead was calculated with Eq. (3) as follows. The actual signal s i measured with each unipolar lead was calculated with Eq. (1). The measurement sensitivity of each unipolar lead to the source was thus taken into account. After the actual signals s i were calculated, we added Gaussian white noise (GWN) to each unipolar lead to simulate the noise n i. Spatially uncorrelated GWN was used to model all of the different noise components. The various noise components include e.g. the background activity generated within the brain, especially on the cortex, other bioelectric signals such as electromyography (EMG), the noise generated at the skin-electrode contact and the noise coupled from the environment. In reality these components differ in amplitude and spatial properties and GWN is most suitable for modeling the non-biological noise components. The standard deviation (SD) of n i was kept equal in every unipolar lead. The SD of n i was 10 times that of the actual signal measured from the lead BL. After the noisy signals (s i + n i ) were generated, the noise-contaminated signal x of the multielectrode lead was calculated with Eq. (3). The SNR of simulated signals was calculated by dividing the standard deviation of the actual signal by the standard deviation of the noise signal Theoretical multielectrode leads In the case of the leads BL, ML58, ML102 and ML202 the source dipole orientation was fixed along the positive z-axis. For each of the leads we generated 2000 noise-contaminated epochs Experimental multielectrode leads To study the difference between the real measurements and simulations, we conducted the simulation study also with the experimental leads. Simulations were conducted both with the experimental multielectrode leads and with the traditional BAEP leads Cz Ai. In each of the simulations, the orientation of the source dipole was set to be parallel to the optimized lead field of the experimental multielectrode lead.
5 310 O. Väisänen, J. Malmivuo / Journal of Physiology - Paris 103 (2009) Results 3.1. Sensitivity distribution analysis In the sensitivity distribution analysis the lead vectors were reciprocally calculated at 2 mm intervals within the brain volume at a total of 267,730 points. As a ROI we defined a sphere of radius 1.0 cm at the center of the model. The sensitivity distributions of the theoretical leads BL, ML58, ML102 and ML202 are illustrated in Fig. 3 and the sensitivity ratios are given in Table 1. The last column gives the values for the optimal uniform sensitivity distribution. The sensitivity distribution analysis was also conducted with the experimental leads. An example of the lead field in an experimental multielectrode lead is illustrated in Fig. 4, where the positive x-axis goes through right mastoid, positive y-axis through nasion and positive z-axis through vertex. The ROISR of the eight optimized experimental multielectrode leads varied between and 0.962, average being The nonroiscv of multielectrode leads was on average 30.1% ( %). In the bipolar leads Cz Ai, the ROISR of the eight studied leads was on average ( ). The nonroiscv of the bipolar lead Cz Ai was on average 56.8% ( %) SNR improvement in theoretical multielectrode leads The characteristics of the SNR improvement obtained with multielectrode leads were studied with the theoretical leads BL, ML58, ML102 and ML202. The results of the simulation study conducted with these leads are plotted in Fig. 5, where the amplitude SNR is plotted as a function of the number of averaged epochs. It can be observed that the improvement obtained with multielectrode leads can be utilized in two different ways. The first alternative improves the quality of the signal and the second shortens the measurement time. The point (a) corresponds to the SNR of the bipolar lead, when 2000 epochs are included in the average. If the same number of epochs is included in the average, the SNR of multielectrode leads is notably higher than that of bipolar lead. Comparing the leads ML58, ML102 and ML202 (point (b)) to lead BL, the SNR is 2.3 times, 2.9 times and 4.2 times higher, respectively. On the other hand, if the purpose is to obtain the same SNR with a multielectrode lead as with a bipolar lead, the number of epochs included in the average can be substantially reduced. The number of epochs needed with multielectrode leads to obtain a SNR similar to that by averaging 2000 epochs with lead BL, is approximately 370, 230 and 120 with leads ML58, ML102 and ML202 (point (c)), respectively. The SNR improvement obtained through temporal averaging is approximately proportional to the square-root of the number of averaged epochs. This was expected because the noise was modeled with GWN. The results of the simulation study show that the SNR of one epoch can be improved by increasing the number of the electrodes in the multielectrode lead. Because each unipolar lead from which the multielectrode lead is synthesized from has different measurement sensitivity to the source, the SNR improvement obtained by increasing the number of electrodes is different from the improvement obtained through temporal averaging. In the case of leads ML58, ML102 and ML202, the effect of spatial averaging is smaller than the effect of temporal averaging SNR improvement in experimental multielectrode leads Examples of BAEP waveforms measured with bipolar leads and with an experimental multielectrode lead are illustrated in Fig. 6. In (a) and (b) the waveforms measured with bipolar leads from one of the testees are presented, when the right ear was stimulated. The waveform of the same signal measured with an optimal multielectrode lead is illustrated in (c). The experimental multielectrode lead is the same as in Fig. 4. In all of the Fig. 6a c 3970 epochs, which is the maximum number of epochs included in the analysis of this dataset, are averaged to obtain the waveforms and thus the SNR is good in every lead. As observed from Fig. 6, the signal amplitude of BAEP waveform is smaller in the multielectrode lead (in (c)) than in bipolar leads ((a) and (b)), because the magnitude of the sensitivity at the center of the head is lower in a multielectrode lead than in a bipolar lead. The difference in the magnitude of sensitivity can be seen also from Fig. 3, where the sensitivity distributions of theoretical leads are illustrated. The SNRs scaled for single epochs were analyzed for six of the measured datasets (Väisänen and Malmivuo, 2007). Two of the eight datasets discussed previously were discarded from the analysis, because of the poor contact impedance of electrode Ai. Both the SNR of the multielectrode leads and bipolar BAEP leads Cz Ai were calculated. The SNR of six of the optimized experimental multielectrode leads was on average 0.19 ( ) and the SNR of six of the bipolar leads Cz Ai was on average 0.11 ( ). Thus in the analysis of the measured data the SNR achieved with optimized multielectrode lead was on average 1.7 ( ) times better than that of bipolar lead Cz Ai. The simulation study was conducted with the same six experimental multielectrode leads and bipolar leads. Because the equations adopted from Raz et al. (1988) estimate the SNR of single epochs, also in the case of simulated signals, we calculated the SNRs of single epochs. The SNR of the six of the optimized experimental multielectrode leads was on average 0.19 ( ) and the SNR of six of the bipolar leads Cz Ai was on average ( ). Thus in the simulation study the SNR achieved with optimized multielectrode lead was on average 2.3 ( ) times better than that of bipolar lead Cz Ai. 4. Discussion Dense EEG electrode arrays can be applied to improve the SNR of traditional bipolar measurements. It is possible to find new bipolar leads which have a higher SNR than the traditionally applied leads. We have now in particular introduced a new multielectrode lead method which further increases the SNR of measurements made to record signals generated deep in the brain Effect of multielectrode leads on sensitivity distribution We analyzed the sensitivity distributions of different leads with the ROISR and nonroiscv parameters. In multielectrode leads both the number and the distribution of electrodes affects to the values of ROISR and nonroiscv. The value of ROISR describes the relative sensitivity of the lead to sources within the ROI. In the theoretical multielectrode leads, where the electrodes are uniformly distributed over the scalp surface, the optimal ROISR of 1.00 is achieved already with 58 electrodes (ML58). In the eight of the optimized experimental multielectrode leads the ROISR was on average 0.953, even though the average number of electrodes was 114. The ROISR is decreased because of the distribution of the electrodes. In experimental measurements an EEG cap was applied, where the electrodes cover only slightly more than half of the head surface. The differences in sensitivity distributions were further observed by looking at the nonroiscv values. The smaller the nonroicv, the less variation there is in the magnitude of sensitivity outside the region of interest i.e. the more uniform the sensitivity
6 O. Väisänen, J. Malmivuo / Journal of Physiology - Paris 103 (2009) Fig. 3. Sensitivity distribution illustrated with lead vectors within the brain plotted on the xz-plane in leads (a) BL, (b) ML58, (c) ML102 and (d) ML202. Colorscale gives the magnitude of the sensitivity distribution J L (A/m 2 ). The positive reciprocal current is applied to white electrodes and the negative to black electrodes. In (b d) weights for unipolar leads are calculated according to Eq. (2). Note that the scaling in the sensitivity distributions is different in (a) than in (b d). Table 1 Calculated sensitivity ratios for theoretical EEG leads. In the fifth column the values for a uniform lead field are given. The ROI is defined as a sphere with a radius of 1 cm at the center of the brain. Lead BL ML58 ML102 ML202 Ideal ML Electrodes ROISR nonroiscv (%) distribution is. The nonroiscv values of theoretical multielectrode leads with uniformly distributed electrodes were below 3%. In experimental multielectrode leads on the other hand the non- ROIScv was on average 30.1%. From the ROISR and nonroiscv values we can conclude that to obtain optimal sensitivity distribution with high ROISR and low nonroiscv value, the number of electrodes in a multielectrode lead needs to be high and the electrodes should be distributed as uniformly as possible Effect of lead field optimization In the experimental multielectrode leads the realistic electrode locations were fitted on the surface of a three-layer spherical head model, and the measurement sensitivity distribution was optimized based on Eq. (2). Also the weights were calculated as if the electrodes were uniformly distributed over a spherical surface. This optimization method does not necessarily result in the most optimal sensitivity distribution for deep sources. By visual evaluation of Fig. 4 and by investigation of the nonroiscv values, it can be observed that sensitivity distributions of the experimental multielectrode leads are less optimal than those of theoretical multielectrode leads (Fig. 3b d) but still improved compared to bipolar leads (Fig. 3a). When the lead field of a multielectrode lead is optimized for deep sources, the goal is to synthesize a uniform sensitivity distribution. If the sensitivity distribution is uniform, the lead is equally sensitive to sources located at different depths if the source orientation is kept fixed. Thus a deviation of the deep source location from the center of the model does not affect to the SNR obtained with the lead. As illustrated in Fig. 3, the sensitivity distribution of theoretical multielectrode leads is uniform almost throughout the whole brain volume. From Fig. 4 it can be seen that the sensitivity distribution of experimental multielectrode leads is less uniform than that of theoretical leads. Thus the SNR of the lead is changed, if the source is not located right at the center of the model.
7 312 O. Väisänen, J. Malmivuo / Journal of Physiology - Paris 103 (2009) Fig. 4. Sensitivity distribution of an experimental multielectrode lead illustrated with lead vectors within the brain plotted on the (a) xz-plane and (b) yz-plane. Colourscale gives the magnitude of sensitivity distribution J L (A/m 2 ). Fig. 5. SNR of different theoretical EEG leads plotted as a function of the number of averaged epochs. The point marked with (a) corresponds to the SNR of the traditional bipolar EEG, when 2000 epochs are included in the average. The improvement obtained with multielectrode leads can be utilized in two different ways, illustrated with grey dashed lines. If the same number of epochs is included in the average, the SNR of multielectrode leads is notably higher than that of bipolar lead (a? b). If the purpose is to obtain the same SNR with a multielectrode lead as with a bipolar lead, the number of epochs included in the average can be substantially reduced (a? c). We evaluated the effect of deep source location on SNR by moving the source dipole within a 2 cm radius from the center of the model in the experimental multielectrode leads. When the source was moved within the 2 cm radius, the SNR was on average the same as when the source was located at the center of the model. When the source location was moved the SNR was at minimum 78% and at maximum 117% of the average SNR. It also has a slight effect on the SNR, whether the source was moved orthogonal or parallel to the lead field orientation. In the former case the variation in SNR is smaller than in the latter case. When the source was moved orthogonal to the lead field orientation, the SNR was on average 101% of the SNR, when the source was located at the center of the model. When the source was moved parallel to the lead field orientation, the SNR was on average 98% of the SNR, when the source was located at the center of the model. The decrease in SNR, when the source is moved parallel to the lead field orientation is caused by the decrease in the magnitude of the sensitivity distribution towards the neck, as illustrated in Fig. 4. A great concern, when considering the deep sources and the synthesization of an optimal sensitivity distribution, is the effect of the head model applied. In the present study we applied the spherical head model because we wanted to evaluate the phenomena behind the improved SNR. Within the spherical head model the optimal uniform sensitivity distribution can be synthesized when the weights for the electrodes are calculated with Eq. (2). The realistically shaped head models are always specific for certain head geometry. Thus the weights needed for the synthesization of an optimal sensitivity distribution, as well as the optimal sensitivity distribution itself, will be different for each individual head geometry. The biggest drawback of the spherical head models is that the deep structures of the brain are not correctly modeled. These include, for example, the ventricles around the brainstem, which have a particularly clear effect on the lead field patterns. Thus for the accurate calculation of the sensitivity distribution the head should be modeled with individual realistically shaped model in the future studies. In this case also a new optimization method needs to be developed to define the weights for the unipolar leads from which the multielectrode lead is synthesized Improvement of SNR with multielectrode leads In the experimental multielectrode leads the number of electrodes was on average 114. In the simulation study the SNR of these multielectrode leads was lower than the SNR achieved with theoretical multielectrode lead ML58, which consists of notably lower number of electrodes uniformly distributed on the spherical scalp surface. This in addition to the evaluation of ROISR and non- ROIScv values emphasizes the need for the development of new electrode montages and sensitivity distribution optimization methods.
8 O. Väisänen, J. Malmivuo / Journal of Physiology - Paris 103 (2009) head more comprehensively, the electrode density remains constant. The efficiency of spatial averaging is a complicated process which strongly depends on the relative magnitudes of the correlated and non-correlated noise sources, which may differ notably between different measurements Multielectrode lead method and beamformers Fig. 6. Example BAEP waveforms. The stimulus was delivered to right ear and 3970 epochs are averaged. (a and b) original BAEP waveforms, (c) BAEP waveform of optimized multielectrode lead (ML). The sensitivity distribution of the multielectrode lead is illustrated in Fig. 4.The studied time interval (TI) includes the peaks IV V. In the experimental measurements the SNR achieved with optimized multielectrode leads was on average 1.7 times better than that of bipolar lead Cz Ai (Väisänen and Malmivuo, 2007). The amplitude SNR improvement by a factor of 1.7 means, that instead of averaging 2000 epochs with a bipolar lead, it is sufficient to average 690 epochs with a multielectrode lead to obtain similar SNR. When the simulation study was conducted with the same experimental leads, the SNR of multielectrode lead was on average 2.3 times better than that of bipolar lead Cz Ai. Thus the SNR improvement achieved in experimental measurements was 75% of the improvement achieved in the simulation study. The main reason for the better SNR improvement obtained in simulations than in experimental measurements was caused by applying an oversimplified noise model in the simulation study. In future investigations the different components of noise should be studied separately, because these components differ in amplitude and spatial properties. As the electrodes are located closer to each other, especially the noise signals generated on the cortex will be correlated over many electrodes (Nunez et al., 1997; Srinivasan et al., 2007). At low frequencies the correlation over different electrodes distances is higher than at high frequencies (Srinivasan et al., 2007). The correlation is caused by both the genuine correlation of cortical sources and the correlation that arises due to volume conduction. At low frequencies the correlation arises due to both of these factors, but at higher frequencies (>30 Hz) the correlation arises mainly due to volume conduction, since the cortical sources at these frequencies are apparently uncorrelated (Srinivasan et al., 2007). In the frequency band which is used to measure BAEPs (>100 Hz), the background EEG might thus be mainly uncorrelated. However, because of the shown volume conductor effects, in the future studies the noise measured from the scalp surface, which is generated within the brain, should be modeled with spatially correlated noise. The correlation of other noise components should also be investigated. When the correlation increases, the efficiency of spatial averaging on improving the SNR will decrease. However, if the number of electrodes is increased by covering the The present multielectrode lead method can be considered as a spatial filtering method. Other widely studied spatial filtering methods include the beamformer methods which provide another means to optimize measurements for sources at different depths within the brain (van Drongelen et al., 1996; Van Veen et al., 1997; Ward et al., 1999). The multielectrode lead Eq. (3) is the same as the output equation of the beamformers (Van Veen et al., 1997). The difference between these two methods is in the selection of the weights w i. Because for deep EEG sources it is impossible to have such a weighted lead field where the magnitude is one at the source location and zero elsewhere, in beamformers the former of these criteria is preserved, while the effect of noise is suppressed by minimizing the variance of the beamformer output. The selection of the weights is made based on the statistics of the measured data and on the lead vector magnitudes only at the source location (Van Veen et al., 1997). In the multielectrode lead method, the weights are defined based on the optimized lead field i.e. the lead vectors at all locations within the brain, not only at the source location. The lead field is optimized by maximizing the relative sensitivity at the source location. Present multielectrode lead method results in the optimal improvement for deep EEG sources, when the noise sources are uniformly distributed within the brain. A great benefit of the present multielectrode lead method is its simplicity. There is no need to estimate the covariance matrix of the measured signals as in beamformers (Van Veen et al., 1997), but it is adequate to only calculate and optimize the lead fields. The multielectrode lead method is also more illustrative, since the best reachable sensitivity distribution in magnitude and direction for deep sources can be visualized. Also the weights can be defined prior to the EEG measurement is conducted Measurement with dense EEG arrays The improvements obtained in the present study encourage for future developments of the method. We assume that the SNR obtained with weighted multielectrode leads can be further improved by first of all developing new electrode montages. These new electrode montages should cover the lower part of the head more comprehensively than traditional EEG montages. Secondly, the optimization of the sensitivity distribution is assumed to be further improved by applying individual realistically shaped head models and new optimization methods to synthesize the optimal sensitivity distribution within realistically shaped head models. A drawback at the moment with dense EEG arrays is the timeconsuming task of applying the electrodes. So long as this process remains as slow as today, the extra time needed to attach a large number of electrodes properly will exceed the time saved with shorter recording time with multielectrode leads. However, new technologies such as amplifiers with higher input impedances and active electrodes will notably cut down the application time. The new multielectrode leads will bring many benefits to EEG studies. Among the first applications are evoked potential studies, where fewer epochs are sufficient for an average without reducing the signal quality. This is important if the response signal tends to change as the number of stimuli is increased. Such changes might arise due to fatigue, learning habituation or other factors. New multielectrode leads more sensitive to measure deep EEG sources
9 314 O. Väisänen, J. Malmivuo / Journal of Physiology - Paris 103 (2009) might also reveal new features of brain activity in spontaneous recordings. 5. Conclusions In the present study we have developed a multielectrode lead technique that can be applied to improve the SNR of EEG generated by deep brainstem sources. We showed with a theoretical approach how the sensitivity distribution of a weighted multielectrode lead should be optimized for deep EEG sources. With simulations we showed that the SNR is improved with multielectrode leads compared to traditional bipolar leads. The improvement of the SNR was validated with preliminary experimental BAEP measurements. In the experimental measurements the amplitude SNR of multielectrode lead was on average 70% higher than the SNR obtained with traditional bipolar lead. To conclude, the SNR of the EEG measurements can be improved with the present weighted multielectrode lead method compared to traditional bipolar leads, when the signals are generated deep in the brain. Acknowledgements This work has been supported by the Finnish Cultural Foundation, the Graduate School of Tampere University of Technology and the Academy of Finland. References Brody, D.A., A method for applying approximately ideal lead connections to homogeneous volume conductors of irregular shape. Am. Heart. J. 53, Causevic, E., Morley, R.E., Wickerhauser, M.V., Jacquin, A.E., Fast wavelet estimation of weak biosignals. IEEE Trans. Biomed. Eng. 52, Chiappa, K., Hill, R., Brainstem auditory evoked potentials: interpretation. In: Chiappa, K. (Ed.), Evoked Potentials in Clinical Medicine. Lippincott-Raven, Philadelphia, pp Davila, C.E., Mobin, M.S., Weighted averaging of evoked potentials. IEEE Trans. Biomed. Eng. 39, Delorme, A., Makeig, S., EEGLAB: an open source toolbox for analysis of singletrial EEG dynamics including independent component analysis. J. Neurosci. Methods 134, Leonowicz, Z., Karvanen, J., Shishkin, S.L., Trimmed estimators for robust averaging of event-related potentials. J. Neurosci. Methods 142, Malmivuo, J., Plonsey, R., Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields. Oxford University Press, New York. Malmivuo, J.A., Suihko, V.E., Effect of skull resistivity on the spatial resolutions of EEG and MEG. IEEE Trans. Biomed. Eng. 51, McFee, R., Johnston, F.D., Electrocardiographic leads. I. Introduction. Circulation 8, Nunez, P.L., Srinivasan, R., Westdorp, A.F., Wijesinghe, R.S., Tucker, D.M., Silberstein, R.B., Cadusch, P.J., EEG coherency. I: statistics, reference electrode, volume conduction, Laplacians, cortical imaging, and interpretation at multiple scales. Electroencephalogr. Clin. Neurophysiol. 103, Nuwer, M.R., Aminoff, M., Goodin, D., Matsuoka, S., Mauguiere, F., Starr, A., Vibert, J.F., IFCN recommended standards for brain-stem auditory evoked potentials. Report of an IFCN committee. International Federation of Clinical Neurophysiology. Electroencephalogr. Clin. Neurophysiol. 91, Oostendorp, T.F., Delbeke, J., Stegeman, D.F., The conductivity of the human skull: results of in vivo and in vitro measurements. IEEE Trans. Biomed. Eng. 47, Ozdamar, O., Kalayci, T., Median averaging of auditory brain stem responses. Ear. Hear. 20, Raz, J., Turetsky, B., Fein, G., Confidence intervals for the signal-to-noise ratio when a signal embedded in noise is observed over repeated trials. IEEE Trans. Biomed. Eng. 35, Rush, S., Driscoll, D.A., EEG electrode sensitivity an application of reciprocity. IEEE Trans. Biomed. Eng. 16, Sörnmo, L., Laguna, P., Bioelectrical Signal Processing in Cardiac and Neurological Applications. Academic press, New York. Srinivasan, R., Winter, W.R., Ding, J., Nunez, P.L., EEG and MEG coherence: measures of functional connectivity at distinct spatial scales of neocortical dynamics. J. Neurosci. Methods 166, Väisänen, O., Malmivuo, J., 2007 Improved detection of deep sources with weighted multielectrode EEG leads. In: 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Lyon, France, pp Väisänen, J., Väisänen, O., Malmivuo, J., Hyttinen, J., New method for analysing sensitivity distributions of electroencephalography measurements. Med. Biol. Eng. Comput. 46, van Drongelen, W., Yuchtman, M., Van Veen, B.D., van Huffelen, A.C., A spatial filtering technique to detect and localize multiple sources in the brain. Brain. Topogr. 9, Van Veen, B.D., van Drongelen, W., Yuchtman, M., Suzuki, A., Localization of brain electrical activity via linearly constrained minimum variance spatial filtering. IEEE Trans. Biomed. Eng. 44, Ward, D.M., Jones, R.D., Bones, P.J., Carroll, G.J., Enhancement of deep epileptiform activity in the EEG via 3-D adaptive spatial filtering. IEEE Trans. Biomed. Eng. 46,
Multichannel EEG Methods to Improve the Spatial Resolution of Cortical Potential Distribution and the Signal Quality of Deep Brain Sources
Julkaisu 741 Publication 741 Outi Väisänen Multichannel EEG Methods to Improve the Spatial Resolution of Cortical Potential Distribution and the Signal Quality of Deep Brain Sources Tampere 2008 Tampereen
Classic EEG (ERPs)/ Advanced EEG. Quentin Noirhomme
Classic EEG (ERPs)/ Advanced EEG Quentin Noirhomme Outline Origins of MEEG Event related potentials Time frequency decomposition i Source reconstruction Before to start EEGlab Fieldtrip (included in spm)
EEG COHERENCE AND PHASE DELAYS: COMPARISONS BETWEEN SINGLE REFERENCE, AVERAGE REFERENCE AND CURRENT SOURCE DENSITY
Version 1, June 13, 2004 Rough Draft form We apologize while we prepare the manuscript for publication but the data are valid and the conclusions are fundamental EEG COHERENCE AND PHASE DELAYS: COMPARISONS
Cortical Source Localization of Human Scalp EEG. Kaushik Majumdar Indian Statistical Institute Bangalore Center
Cortical Source Localization of Human Scalp EEG Kaushik Majumdar Indian Statistical Institute Bangalore Center Cortical Basis of Scalp EEG Baillet et al, IEEE Sig Proc Mag, Nov 2001, p 16 Mountcastle,
Data Analysis Methods: Net Station 4.1 By Peter Molfese
Data Analysis Methods: Net Station 4.1 By Peter Molfese Preparing Data for Statistics (preprocessing): 1. Rename your files to correct any typos or formatting issues. a. The General format for naming files
Documentation Wadsworth BCI Dataset (P300 Evoked Potentials) Data Acquired Using BCI2000's P3 Speller Paradigm (http://www.bci2000.
Documentation Wadsworth BCI Dataset (P300 Evoked Potentials) Data Acquired Using BCI2000's P3 Speller Paradigm (http://www.bci2000.org) BCI Competition III Challenge 2004 Organizer: Benjamin Blankertz
Chapter 22: Electric Flux and Gauss s Law
22.1 ntroduction We have seen in chapter 21 that determining the electric field of a continuous charge distribution can become very complicated for some charge distributions. t would be desirable if we
Overview of Methodology. Human Electrophysiology. Computing and Displaying Difference Waves. Plotting The Averaged ERP
Human Electrophysiology Overview of Methodology This Week: 1. Displaying ERPs 2. Defining ERP components Analog Filtering Amplification Montage Selection Analog-Digital Conversion Signal-to-Noise Enhancement
Functional neuroimaging. Imaging brain function in real time (not just the structure of the brain).
Functional neuroimaging Imaging brain function in real time (not just the structure of the brain). The brain is bloody & electric Blood increase in neuronal activity increase in metabolic demand for glucose
ε: Voltage output of Signal Generator (also called the Source voltage or Applied
Experiment #10: LR & RC Circuits Frequency Response EQUIPMENT NEEDED Science Workshop Interface Power Amplifier (2) Voltage Sensor graph paper (optional) (3) Patch Cords Decade resistor, capacitor, and
ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES
ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES The purpose of this lab session is to experimentally investigate the relation between electric field lines of force and equipotential surfaces in two dimensions.
Frequency Response of Filters
School of Engineering Department of Electrical and Computer Engineering 332:224 Principles of Electrical Engineering II Laboratory Experiment 2 Frequency Response of Filters 1 Introduction Objectives To
11.1. Objectives. Component Form of a Vector. Component Form of a Vector. Component Form of a Vector. Vectors and the Geometry of Space
11 Vectors and the Geometry of Space 11.1 Vectors in the Plane Copyright Cengage Learning. All rights reserved. Copyright Cengage Learning. All rights reserved. 2 Objectives! Write the component form of
SCHWEITZER ENGINEERING LABORATORIES, COMERCIAL LTDA.
Pocket book of Electrical Engineering Formulas Content 1. Elementary Algebra and Geometry 1. Fundamental Properties (real numbers) 1 2. Exponents 2 3. Fractional Exponents 2 4. Irrational Exponents 2 5.
Determine whether the following lines intersect, are parallel, or skew. L 1 : x = 6t y = 1 + 9t z = 3t. x = 1 + 2s y = 4 3s z = s
Homework Solutions 5/20 10.5.17 Determine whether the following lines intersect, are parallel, or skew. L 1 : L 2 : x = 6t y = 1 + 9t z = 3t x = 1 + 2s y = 4 3s z = s A vector parallel to L 1 is 6, 9,
Manual Analysis Software AFD 1201
AFD 1200 - AcoustiTube Manual Analysis Software AFD 1201 Measurement of Transmission loss acc. to Song and Bolton 1 Table of Contents Introduction - Analysis Software AFD 1201... 3 AFD 1200 - AcoustiTube
Convolution. 1D Formula: 2D Formula: Example on the web: http://www.jhu.edu/~signals/convolve/
Basic Filters (7) Convolution/correlation/Linear filtering Gaussian filters Smoothing and noise reduction First derivatives of Gaussian Second derivative of Gaussian: Laplacian Oriented Gaussian filters
potential in the centre of the sphere with respect to infinity.
Umeå Universitet, Fysik 1 Vitaly Bychkov Prov i fysik, Electricity and Waves, 2006-09-27, kl 16.00-22.00 Hjälpmedel: Students can use any book. Define the notations you are using properly. Present your
Solving Simultaneous Equations and Matrices
Solving Simultaneous Equations and Matrices The following represents a systematic investigation for the steps used to solve two simultaneous linear equations in two unknowns. The motivation for considering
Comparison of the Response of a Simple Structure to Single Axis and Multiple Axis Random Vibration Inputs
Comparison of the Response of a Simple Structure to Single Axis and Multiple Axis Random Vibration Inputs Dan Gregory Sandia National Laboratories Albuquerque NM 87185 (505) 844-9743 Fernando Bitsie Sandia
Masters research projects. 1. Adapting Granger causality for use on EEG data.
Masters research projects 1. Adapting Granger causality for use on EEG data. Background. Granger causality is a concept introduced in the field of economy to determine which variables influence, or cause,
Laboratory Guide. Anatomy and Physiology
Laboratory Guide Anatomy and Physiology TBME04, Fall 2010 Name: Passed: Last updated 2010-08-13 Department of Biomedical Engineering Linköpings Universitet Introduction This laboratory session is intended
DINAMIC AND STATIC CENTRE OF PRESSURE MEASUREMENT ON THE FORCEPLATE. F. R. Soha, I. A. Szabó, M. Budai. Abstract
ACTA PHYSICA DEBRECINA XLVI, 143 (2012) DINAMIC AND STATIC CENTRE OF PRESSURE MEASUREMENT ON THE FORCEPLATE F. R. Soha, I. A. Szabó, M. Budai University of Debrecen, Department of Solid State Physics Abstract
Author: Dr. Society of Electrophysio. Reference: Electrodes. should include: electrode shape size use. direction.
Standards for Reportin ng EMG Data Author: Dr. Roberto Merletti, Politecnico di Torino, Italy The Standards for Reporting EMG Data, written by Dr. Robertoo Merletti, are endorsed by the International Society
A Method for Measuring Amplitude and Phase of Each Radiating Element of a Phased Array Antenna
Electronics and Communications in Japan, Vol. 65-B, No. 5, 1982 A Method for Measuring Amplitude and Phase of Each Radiating Element of a Phased Array Antenna Seiji Mano and Takashi Katagi, Regular Members
Building a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH
g.tec medical engineering GmbH Sierningstrasse 14, A-4521 Schiedlberg Austria - Europe Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 [email protected], http://www.gtec.at Building a Simulink model for real-time
Video-Based Eye Tracking
Video-Based Eye Tracking Our Experience with Advanced Stimuli Design for Eye Tracking Software A. RUFA, a G.L. MARIOTTINI, b D. PRATTICHIZZO, b D. ALESSANDRINI, b A. VICINO, b AND A. FEDERICO a a Department
5-Axis Test-Piece Influence of Machining Position
5-Axis Test-Piece Influence of Machining Position Michael Gebhardt, Wolfgang Knapp, Konrad Wegener Institute of Machine Tools and Manufacturing (IWF), Swiss Federal Institute of Technology (ETH), Zurich,
SIMPLIFIED PERFORMANCE MODEL FOR HYBRID WIND DIESEL SYSTEMS. J. F. MANWELL, J. G. McGOWAN and U. ABDULWAHID
SIMPLIFIED PERFORMANCE MODEL FOR HYBRID WIND DIESEL SYSTEMS J. F. MANWELL, J. G. McGOWAN and U. ABDULWAHID Renewable Energy Laboratory Department of Mechanical and Industrial Engineering University of
Electrocardiography I Laboratory
Introduction The body relies on the heart to circulate blood throughout the body. The heart is responsible for pumping oxygenated blood from the lungs out to the body through the arteries and also circulating
CHAPTER 5 PREDICTIVE MODELING STUDIES TO DETERMINE THE CONVEYING VELOCITY OF PARTS ON VIBRATORY FEEDER
93 CHAPTER 5 PREDICTIVE MODELING STUDIES TO DETERMINE THE CONVEYING VELOCITY OF PARTS ON VIBRATORY FEEDER 5.1 INTRODUCTION The development of an active trap based feeder for handling brakeliners was discussed
Simple Harmonic Motion
Simple Harmonic Motion 1 Object To determine the period of motion of objects that are executing simple harmonic motion and to check the theoretical prediction of such periods. 2 Apparatus Assorted weights
TECHNICAL SPECIFICATIONS, VALIDATION, AND RESEARCH USE CONTENTS:
TECHNICAL SPECIFICATIONS, VALIDATION, AND RESEARCH USE CONTENTS: Introduction to Muse... 2 Technical Specifications... 3 Research Validation... 4 Visualizing and Recording EEG... 6 INTRODUCTION TO MUSE
Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives
Physics 9e/Cutnell correlated to the College Board AP Physics 1 Course Objectives Big Idea 1: Objects and systems have properties such as mass and charge. Systems may have internal structure. Enduring
IN current film media, the increase in areal density has
IEEE TRANSACTIONS ON MAGNETICS, VOL. 44, NO. 1, JANUARY 2008 193 A New Read Channel Model for Patterned Media Storage Seyhan Karakulak, Paul H. Siegel, Fellow, IEEE, Jack K. Wolf, Life Fellow, IEEE, and
Palmprint Recognition. By Sree Rama Murthy kora Praveen Verma Yashwant Kashyap
Palmprint Recognition By Sree Rama Murthy kora Praveen Verma Yashwant Kashyap Palm print Palm Patterns are utilized in many applications: 1. To correlate palm patterns with medical disorders, e.g. genetic
Designer-Oriented Electric Field Analysis System for Power Cable Accessories
ANALYSIS TECHNOLOGY er-oriented Electric Field Analysis System for Power Cable Accessories Yuuichi NAKAMURA*, Tomohiro KEISHI and Miki USUI Sumitomo Electric has worked on electric for more than 30 years.
Free software solutions for MEG/EEG source imaging
Free software solutions for MEG/EEG source imaging François Tadel Cognitive Neuroscience & Brain Imaging Lab., CNRS University of Paris - Hôpital de la Salpêtrière Cognitive Neuroimaging Unit, Inserm U562
P300 Spelling Device with g.usbamp and Simulink V3.12.03. Copyright 2012 g.tec medical engineering GmbH
g.tec medical engineering GmbH 4521 Schiedlberg, Sierningstrasse 14, Austria Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 [email protected], http://www.gtec.at P300 Spelling Device with g.usbamp and Simulink
INVESTIGATION OF ELECTRIC FIELD INTENSITY AND DEGREE OF UNIFORMITY BETWEEN ELECTRODES UNDER HIGH VOLTAGE BY CHARGE SIMULATIO METHOD
INVESTIGATION OF ELECTRIC FIELD INTENSITY AND DEGREE OF UNIFORMITY BETWEEN ELECTRODES UNDER HIGH VOLTAGE BY CHARGE SIMULATIO METHOD Md. Ahsan Habib, Muhammad Abdul Goffar Khan, Md. Khaled Hossain, Shafaet
Sound absorption and acoustic surface impedance
Sound absorption and acoustic surface impedance CHRISTER HEED SD2165 Stockholm October 2008 Marcus Wallenberg Laboratoriet för Ljud- och Vibrationsforskning Sound absorption and acoustic surface impedance
ERPs in Cognitive Neuroscience
Center for Neuroscience UNIVERSITY OF CALIFORNIA AT DAVIS ERPs in Cognitive Neuroscience Charan Ranganath Center for Neuroscience and Dept of Psychology, UC Davis EEG and MEG Neuronal activity generates
ELECTRON SPIN RESONANCE Last Revised: July 2007
QUESTION TO BE INVESTIGATED ELECTRON SPIN RESONANCE Last Revised: July 2007 How can we measure the Landé g factor for the free electron in DPPH as predicted by quantum mechanics? INTRODUCTION Electron
TCOM 370 NOTES 99-4 BANDWIDTH, FREQUENCY RESPONSE, AND CAPACITY OF COMMUNICATION LINKS
TCOM 370 NOTES 99-4 BANDWIDTH, FREQUENCY RESPONSE, AND CAPACITY OF COMMUNICATION LINKS 1. Bandwidth: The bandwidth of a communication link, or in general any system, was loosely defined as the width of
Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19
Doppler Doppler Chapter 19 A moving train with a trumpet player holding the same tone for a very long time travels from your left to your right. The tone changes relative the motion of you (receiver) and
VEHICLE TRACKING USING ACOUSTIC AND VIDEO SENSORS
VEHICLE TRACKING USING ACOUSTIC AND VIDEO SENSORS Aswin C Sankaranayanan, Qinfen Zheng, Rama Chellappa University of Maryland College Park, MD - 277 {aswch, qinfen, rama}@cfar.umd.edu Volkan Cevher, James
International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters
www.led-professional.com ISSN 1993-890X Trends & Technologies for Future Lighting Solutions ReviewJan/Feb 2015 Issue LpR 47 International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in
Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi
Diffusione e perfusione in risonanza magnetica E. Pagani, M. Filippi DW-MRI DIFFUSION-WEIGHTED MRI Principles Diffusion results from a microspic random motion known as Brownian motion THE RANDOM WALK How
The Fourth International DERIVE-TI92/89 Conference Liverpool, U.K., 12-15 July 2000. Derive 5: The Easiest... Just Got Better!
The Fourth International DERIVE-TI9/89 Conference Liverpool, U.K., -5 July 000 Derive 5: The Easiest... Just Got Better! Michel Beaudin École de technologie supérieure 00, rue Notre-Dame Ouest Montréal
Plate waves in phononic crystals slabs
Acoustics 8 Paris Plate waves in phononic crystals slabs J.-J. Chen and B. Bonello CNRS and Paris VI University, INSP - 14 rue de Lourmel, 7515 Paris, France [email protected] 41 Acoustics 8 Paris We
Incorporating Internal Gradient and Restricted Diffusion Effects in Nuclear Magnetic Resonance Log Interpretation
The Open-Access Journal for the Basic Principles of Diffusion Theory, Experiment and Application Incorporating Internal Gradient and Restricted Diffusion Effects in Nuclear Magnetic Resonance Log Interpretation
Name Class. Date Section. Test Form A Chapter 11. Chapter 11 Test Bank 155
Chapter Test Bank 55 Test Form A Chapter Name Class Date Section. Find a unit vector in the direction of v if v is the vector from P,, 3 to Q,, 0. (a) 3i 3j 3k (b) i j k 3 i 3 j 3 k 3 i 3 j 3 k. Calculate
Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.
Optiffuser High-performance, high bandwidth lightweight 1D diffuser. General product information The Optiffuser comes in packs of four panels. Two positives and two negatives (see page 5) per package.
NeXus: Event-Related potentials Evoked potentials for Psychophysiology & Neuroscience
NeXus: Event-Related potentials Evoked potentials for Psychophysiology & Neuroscience This NeXus white paper has been created to educate and inform the reader about the Event Related Potentials (ERP) and
WAVELET ANALYSIS BASED ULTRASONIC NONDESTRUCTIVE TESTING OF POLYMER BONDED EXPLOSIVE
WAVELET ANALYSIS BASED ULTRASONIC NONDESTRUCTIVE TESTING OF POLYMER BONDED EXPLOSIVE Weibin Zhang, Yong Tian, Zhanfeng Yang, Liling Wang Institute of Chemical Materials, China Academy of Engineering Physics,
The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT
The Effect of Network Cabling on Bit Error Rate Performance By Paul Kish NORDX/CDT Table of Contents Introduction... 2 Probability of Causing Errors... 3 Noise Sources Contributing to Errors... 4 Bit Error
ALLEN Mouse Brain Atlas
TECHNICAL WHITE PAPER: QUALITY CONTROL STANDARDS FOR HIGH-THROUGHPUT RNA IN SITU HYBRIDIZATION DATA GENERATION Consistent data quality and internal reproducibility are critical concerns for high-throughput
Component Ordering in Independent Component Analysis Based on Data Power
Component Ordering in Independent Component Analysis Based on Data Power Anne Hendrikse Raymond Veldhuis University of Twente University of Twente Fac. EEMCS, Signals and Systems Group Fac. EEMCS, Signals
Convention Paper Presented at the 112th Convention 2002 May 10 13 Munich, Germany
Audio Engineering Society Convention Paper Presented at the 112th Convention 2002 May 10 13 Munich, Germany This convention paper has been reproduced from the author's advance manuscript, without editing,
Type-D EEG System for Regular EEG Clinic
Type-D EEG System for Regular EEG Clinic Type-D EEG amplifier Specifications 1. For Type-D Amplifier Input channels: 12/24/36/48 Monopolar EEG + 12channels Bipolar EEG+12 channels PSG. Power supply: Internal
CONCEPT-II. Overview of demo examples
CONCEPT-II CONCEPT-II is a frequency domain method of moment (MoM) code, under development at the Institute of Electromagnetic Theory at the Technische Universität Hamburg-Harburg (www.tet.tuhh.de). Overview
Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x
CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this
Optimizing IP3 and ACPR Measurements
Optimizing IP3 and ACPR Measurements Table of Contents 1. Overview... 2 2. Theory of Intermodulation Distortion... 2 3. Optimizing IP3 Measurements... 4 4. Theory of Adjacent Channel Power Ratio... 9 5.
CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging
Physics of Medical X-Ray Imaging (1) Chapter 3 CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY 3.1 Basic Concepts of Digital Imaging Unlike conventional radiography that generates images on film through
SPINDLE ERROR MOVEMENTS MEASUREMENT ALGORITHM AND A NEW METHOD OF RESULTS ANALYSIS 1. INTRODUCTION
Journal of Machine Engineering, Vol. 15, No.1, 2015 machine tool accuracy, metrology, spindle error motions Krzysztof JEMIELNIAK 1* Jaroslaw CHRZANOWSKI 1 SPINDLE ERROR MOVEMENTS MEASUREMENT ALGORITHM
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE References for Nuclear Magnetic Resonance 1. Slichter, Principles of Magnetic Resonance, Harper and Row, 1963. chapter
Metrol. Meas. Syst., Vol. XVII (2010), No. 1, pp. 119-126 METROLOGY AND MEASUREMENT SYSTEMS. Index 330930, ISSN 0860-8229 www.metrology.pg.gda.
Metrol. Meas. Syst., Vol. XVII (21), No. 1, pp. 119-126 METROLOGY AND MEASUREMENT SYSTEMS Index 3393, ISSN 86-8229 www.metrology.pg.gda.pl MODELING PROFILES AFTER VAPOUR BLASTING Paweł Pawlus 1), Rafał
Brain Computer Interfaces (BCI) Communication Training of brain activity
Brain Computer Interfaces (BCI) Communication Training of brain activity Brain Computer Interfaces (BCI) picture rights: Gerwin Schalk, Wadsworth Center, NY Components of a Brain Computer Interface Applications
In-situ Load Testing to Evaluate New Repair Techniques
In-situ Load Testing to Evaluate New Repair Techniques W.J. Gold 1 and A. Nanni 2 1 Assistant Research Engineer, Univ. of Missouri Rolla, Dept. of Civil Engineering 2 V&M Jones Professor, Univ. of Missouri
INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS
INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS Tom Kimerling University of Massachusetts, Amherst MIE 605 Finite Element Analysis Spring 2002 ABSTRACT A FEA transient thermal structural
Three phase circuits
Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors
CHAPTER4 GENERAL ASPECTS OF MUTUAL
CHAPTER4 GENERAL ASPECTS OF MUTUAL ADMITTANCE OF CPW-FED TWIN SLOTS ON CONDUCTOR-BACKED TWO-LAYER SUBSTRATES 4.1 INTRODUCTORY REMARKS The present chapter is concerned with an exploratory investigation
The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen
A technology primer from NORDX/CDT By, Eric d Allmen Foreword The Telecommunications Industry Association (TIA) and the International Standards Organization (ISO/IEC) are actively engaged in the development
Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive
International Journal of Electronic and Electrical Engineering. ISSN 0974-2174 Volume 7, Number 10 (2014), pp. 1027-1035 International Research Publication House http://www.irphouse.com Simulation and
Dr. Abdel Aziz Hussein Lecturer of Physiology Mansoura Faculty of Medicine
Physiological Basis of Hearing Tests By Dr. Abdel Aziz Hussein Lecturer of Physiology Mansoura Faculty of Medicine Introduction Def: Hearing is the ability to perceive certain pressure vibrations in the
Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz
Author: Don LaFontaine Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz Abstract Making accurate voltage and current noise measurements on op amps in
Standards for surface electromyography: the European project "Surface EMG for non-invasive assessment of muscles (SENIAM)
Standards for surface electromyography: the European project "Surface EMG for non-invasive assessment of muscles (SENIAM) D.F. Stegeman 1,3, H.J. Hermens 2 1 Institute of Neurology, Department of Clinical
Frequency-domain and stochastic model for an articulated wave power device
Frequency-domain stochastic model for an articulated wave power device J. Cândido P.A.P. Justino Department of Renewable Energies, Instituto Nacional de Engenharia, Tecnologia e Inovação Estrada do Paço
Subjects: Fourteen Princeton undergraduate and graduate students were recruited to
Supplementary Methods Subjects: Fourteen Princeton undergraduate and graduate students were recruited to participate in the study, including 9 females and 5 males. The mean age was 21.4 years, with standard
FREQUENCY RESPONSE ANALYZERS
FREQUENCY RESPONSE ANALYZERS Dynamic Response Analyzers Servo analyzers When you need to stabilize feedback loops to measure hardware characteristics to measure system response BAFCO, INC. 717 Mearns Road
Two vectors are equal if they have the same length and direction. They do not
Vectors define vectors Some physical quantities, such as temperature, length, and mass, can be specified by a single number called a scalar. Other physical quantities, such as force and velocity, must
EM Clustering Approach for Multi-Dimensional Analysis of Big Data Set
EM Clustering Approach for Multi-Dimensional Analysis of Big Data Set Amhmed A. Bhih School of Electrical and Electronic Engineering Princy Johnson School of Electrical and Electronic Engineering Martin
The Fourier Analysis Tool in Microsoft Excel
The Fourier Analysis Tool in Microsoft Excel Douglas A. Kerr Issue March 4, 2009 ABSTRACT AD ITRODUCTIO The spreadsheet application Microsoft Excel includes a tool that will calculate the discrete Fourier
Tonal Detection in Noise: An Auditory Neuroscience Insight
Image: http://physics.ust.hk/dusw/ Tonal Detection in Noise: An Auditory Neuroscience Insight Buddhika Karunarathne 1 and Richard H.Y. So 1,2 1 Dept. of IELM, Hong Kong University of Science & Technology,
Part 4 fitting with energy loss and multiple scattering non gaussian uncertainties outliers
Part 4 fitting with energy loss and multiple scattering non gaussian uncertainties outliers material intersections to treat material effects in track fit, locate material 'intersections' along particle
BARE PCB INSPECTION BY MEAN OF ECT TECHNIQUE WITH SPIN-VALVE GMR SENSOR
BARE PCB INSPECTION BY MEAN OF ECT TECHNIQUE WITH SPIN-VALVE GMR SENSOR K. Chomsuwan 1, S. Yamada 1, M. Iwahara 1, H. Wakiwaka 2, T. Taniguchi 3, and S. Shoji 4 1 Kanazawa University, Kanazawa, Japan;
Deriving the 12-lead Electrocardiogram From Four Standard Leads Based on the Frank Torso Model
Deriving the 12-lead Electrocardiogram From Four Standard Leads Based on the Frank Torso Model Daming Wei Graduate School of Information System The University of Aizu, Fukushima Prefecture, Japan A b s
11. Rotation Translational Motion: Rotational Motion:
11. Rotation Translational Motion: Motion of the center of mass of an object from one position to another. All the motion discussed so far belongs to this category, except uniform circular motion. Rotational
Log-Likelihood Ratio-based Relay Selection Algorithm in Wireless Network
Recent Advances in Electrical Engineering and Electronic Devices Log-Likelihood Ratio-based Relay Selection Algorithm in Wireless Network Ahmed El-Mahdy and Ahmed Walid Faculty of Information Engineering
1 Introduction. JS'12, Cnam Paris, 3-4 Avril 2012. Ourouk Jawad 1, David Lautru 2, Jean Michel Dricot, François Horlin, Philippe De Doncker 3
Statistical Study of SAR under Wireless Channel Exposure in Indoor Environment Etude Statistique du DAS sous Exposition d un Canal sans Fils en Environnement Intérieur Ourouk Jawad 1, David Lautru 2, Jean
8 Speed control of Induction Machines
8 Speed control of Induction Machines We have seen the speed torque characteristic of the machine. In the stable region of operation in the motoring mode, the curve is rather steep and goes from zero torque
Simple Random Sampling
Source: Frerichs, R.R. Rapid Surveys (unpublished), 2008. NOT FOR COMMERCIAL DISTRIBUTION 3 Simple Random Sampling 3.1 INTRODUCTION Everyone mentions simple random sampling, but few use this method for
Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22
BL_01 A thin flat plate 55 by 110 cm is immersed in a 6 m/s stream of SAE 10 oil at 20 C. Compute the total skin friction drag if the stream is parallel to (a) the long side and (b) the short side. D =
Derive 5: The Easiest... Just Got Better!
Liverpool John Moores University, 1-15 July 000 Derive 5: The Easiest... Just Got Better! Michel Beaudin École de Technologie Supérieure, Canada Email; [email protected] 1. Introduction Engineering
An octave bandwidth dipole antenna
An octave bandwidth dipole antenna Abstract: Achieving wideband performance from resonant structures is challenging because their radiation properties and impedance characteristics are usually sensitive
Effects of microphone arrangement on the accuracy of a spherical microphone array (SENZI) in acquiring high-definition 3D sound space information
November 1, 21 1:3 1 Effects of microphone arrangement on the accuracy of a spherical microphone array (SENZI) in acquiring high-definition 3D sound space information Shuichi Sakamoto 1, Jun ichi Kodama
