PRODUCT DATA. Hand-held Analyzer Type 2250-L (2250 Light) Uses and Features
|
|
|
- Kathlyn Tate
- 10 years ago
- Views:
Transcription
1 PRODUCT DATA Hand-held Analyzer Type 2250-L (2250 Light) Hand-held Analyzer Type 2250-L (2250 Light) has been developed specifically for measuring occupational, environmental and product noise, while complying fully with all the relevant national and international standards. Extensive user studies have been paired with state-of-the-art technology to make this analyzer a robust, effective and practical tool for those applications. Using the large, high-contrast, touch screen interface, the analyzer can easily be set up to display and measure just what is needed from the extensive list of parameters provided by the analyzer. Together with Measurement Partner Field App, MP Cloud and Measurement Partner Suite for post-processing, 2250 Light is a complete solution for your measurement needs. Uses and Features Uses Environmental noise assessment Occupational noise evaluation Hearing protection selection Noise reduction Product quality control General purpose Class 1 sound measurements Real-time analysis of sound in 1/1- and 1/3-octave bands Tone assessment using 1/3-octave methods Loudness and noise rating measurements Time history analysis for broadband parameters and spectra (Logging) Audiometer calibration Features Hardware Large, high-resolution, touch-sensitive colour screen 'Traffic light status indicator Plug-in rechargeable Li-ion battery (> 8 h operation) Robust and environmentally protected (IP 44) Data storage on high-capacity plug-in memory cards or USB flash drive USB 2.0 host for connection to printer, GPS, weather station, modem Upgrade to Type 2250 or 2270 with the trade-in program Software Multilingual user interface: 23 languages 120 db dynamic range up to 140 db 24- or 16-bit recording of all or parts of a measurement Broadband and spectrum logging (optional BZ-7133) Logging profile display with markers (optional BZ-7133) Back-erase for manual delete of unwanted noise events Full Measurement Partner Suite support software for archiving, exporting and post-processing Simultaneous measurement of noise and weather parameters with weather station Measurement Partner Cloud Measurement Partner Field App (ios, Android)
2 Applications and Hardware Introduction Type 2250-L is built on the core platform of the award winning design of Type 2250 and maintains the renowned Brüel & Kjær measurement excellence and the Type 2250 platform s ease of use in an efficient and versatile sound measurement instrument. Whether addressing workplace noise compliance, environmental noise assessment, or product noise certification, Type 2250-L offers the functionality needed to meet your requirements. Type 2250-L is fully compliant with IEC (see the specifications section for compliance information) and is delivered with a number of predefined measurement templates tailored to suit specific requirements. The comfortable and secure design feels safe in your hand, and the buttons fall precisely where they need to be for a one-thumb operated Start, Stop and Save. The Traffic Light indicator surrounding the Start/Pause pushbutton gives you an immediate visual indication of measurement status, even in the brightest sunshine. The large, high contrast, touchscreen/display, lets you select parameters on the display and easily store those setups in your Type 2250-L for future measurements. When on site, the weather station kit measures weather parameters that are stored on Type 2250-L together with the noise data. Measurement Partner Field App provides measurement annotation and control, keeping you out of the sound field and improving the quality of your measurement. After completion, upload your measurement data to MP Cloud and it is ready for you or a colleague to postprocess using Measurement Partner Suite, which has tools to help you extract exactly what you need from your data. This data sheet describes the suite of software applications available for Type 2250-L. All analyzers come with the Sound Level Meter Software for Type 2250-L (BZ-7130) included. Upgrade to full Type 2250 or 2270: Type 2250-L can be upgraded to a Hand-held Analyzer Type 2250 or 2270, which have more features and supports a wider range of applications, such as enhanced logging, triggered signal recording and reverberation time software (see Product Data BP 2025 for more information). The upgrade is on an exchange basis, contact your local Brüel & Kjær representative for details. Workplace and Industrial Hygiene Noise Measurement Applications Type 2250-L is an easy-to-use, powerful tool to make you more productive, and more confident measuring noise at work. Type 2250-L was developed with workplace noise as a special concern. Type 2250-L has all the necessary occupational health noise parameters. It can measure Fast and Slow and A- and C-weighted SPLs simultaneously (along with a separately weighted peak detector) so that the values you need to specify hearing protection are immediately on the display. Parallel analysis allows you to compare a 3 db exchange rate average measurement with a selectable alternate 4, 5 or 6 db exchange rate, including separate dose, expected dose and exposure values. Type 2250-L offers three independent threshold peak event counters, along with simultaneous Fast, Slow and Impulse RMS detectors, to assess impulsive noise. 2
3 With the optional 1/1- and 1/3-octave frequency analysis software options, instantly assess noise control and detailed hearing-protection requirements for a surveyed location. All the octaves are measured at the same instant, along with broadband A- and C-weighted values, so there is no filter switching or range changing. Sometimes noise levels in the workplace vary dramatically, and perhaps irregularly. To assess this kind of noise it is helpful to measure and analyse a noise profile a measurement that shows how the sound varies with time. The logging option for Type 2250-L provides this capability in a natural, intuitive way. If you have installed the 1/1- or 1/3-octave real-time frequency analysis option, Type 2250-L seamlessly integrates the spectrum information into the noise profile. Signal Recording Option BZ-7226 lets you record the measurement signal in order to identify and document sound sources. Easily export, archive and report your measurements using Measurement Partner Suite BZ-5503, or export the results to Brüel & Kjær s Protector Type 7825, where you can organize and document a company s noise and hearing conservation program. Type 7825 calculates noise exposure according to ISO Environmental Noise Assessment Applications The tasks for environmental noise measurements are varied, so the instrument you pick for your measurements needs to be flexible, easy to configure, powerful and accurate. Type 2250-L is all that and more, ideal for a simple noise enforcement measurement one moment and for a complex environmental impact survey the next. Type 2250-L with included Sound Level Meter software BZ-7130 is ideal for spot noise enforcement checks. Press the Start pushbutton and, when ready, press the same button to stop the measurement. Press the Save pushbutton and you will not only be saving the results, but also the time and duration of the measurement and the date and time of the last calibration. Type 2250-L can measure all the parameters needed for environmental noise, including dual frequency weightings, Fast, Slow, and Impulse Time Averaging, L eq s and a full range of statistical distributions. Just as important, you can set Type 2250-L to display only the parameters you need and save that display so Type 2250-L starts, tailor-made for your use, every time. For more involved environmental applications, you will need to add the Logging option. Now you can set the analyzer to record all, or up to ten selected measurement results at intervals from one second to one day, for a duration up to 1 month. The display offers two simultaneous views, one of the complete profile and a zoomed-in 100-sample window, that are intuitively linked by the cursor. For the precise timing of noise events, an alternative Fast Log view gives you the L AF, L AS and L Aeq results for 100 ms intervals. In either the fast log, or profile view, you can define up to five different markers anywhere in the profile, to identify noise sources or events. When you use the real-time frequency analysis options, 1/1-octave or 1/3-octave, the frequency spectrum average, maximum and minimum values can be logged along with the overall values. With the Tone Assessment Option, annoying tones in the spectrum can be assessed according to the ISO 1996 standard. Save and view the noise profiles on your Microsoft Windows PC using Measurement Partner Suite and use its optional modules for noise assessment based on logging and frequency analysis. Make these measurements with the incredible 120 db dynamic range of Type 2250-L, allowing measurements from the low noise floor of the analyzer to over 140 db. Without a range switch to consider, you can now make measurements without fear of overload, and still capture the nuances of a silent night. Type 2250-L is an ideal entry point to safe, easy and precise environmental noise measurements. 3
4 Product Noise Measurement Brüel & Kjær long ago set the standard for product noise measurements. Now, whether you have a simple A-weighted sound limit requirement, or need to evaluate a 1/3-octave reverberation chamber sound power test, Type 2250-L is scalable to your requirements. Type 2250-L can be used as a hand-held device for easy portability, or it can be operated using your Windows PC as an online-, USB- or LAN-controlled device in your laboratory. The user-defined templates make switching between applications easy. The wide 120 db dynamic range of Type 2250-L eliminates concern for overloads, and you can set a preset measurement time to add consistency to your measurements. Use the built-in headphone style (3.5 mm) output jack to send the signal out to other measurement instrumentation. Measurement Partner Suite (included) makes it easy to keep track of results in an organized archive structure. 4
5 Fig. 1 Key features of Hand-held Analyzer Type 2250 Navigation Pushbuttons: Up/down, left/right arrow keys The Hand-held Analyzer Hardware Great care has been taken to ensure that the hardware is ergonomically optimal in field use. The key features of Type 2250 Light are shown in Fig. 1. Microphone/Preamplifier Stage: Falcon Range ½ microphone and microphone preamplifier stage The microphone preamplifier stage is able to drive an extension cable of up to 100 m, a valuable feature when a measurement requires remote location of the microphone Event Pushbutton: For marking events Stylus (stored) Back Erase/Exclude Pushbutton: Allows you to erase the last 5 s of data Mark logged data with an exclude marker Start/Pause Pushbutton: Press to start a measurement Press to pause a measurement Reset Measurement Pushbutton: Reset Type 2250-L s measurement buffers Display: Touch-sensitive colour screen with backlight Event 2 Pushbutton: A second pushbutton for marking a second event Accept Pushbutton: Accepts any changes made to parameters/setups Red, yellow, green Status Indicators Store Pushbutton: Store measurement results Mounting thread Non-slip surfaces for safe grip Battery Compartment for rechargeable battery pack Power Switch G4 indicates hardware version 4 Cover for protecting connectors Thread for tripod/wrist strap Output Socket: Not used 3.5 mm Stereo Socket for Headphones: For reviewing recorded comments or listening to measurement signals Trigger Input Input: Not used Micro USB Wi-Fi dongle UL-1050 USB 2.0 (On-the-Go) Micro-AB socket: Allows data transfer and remote control of the analyzer directly with a host PC Reset button USB 2.0 Standard A socket For connection to USB peripherals High-speed LAN Interface Battery Charge: 8 24 V DC input from a universal mains adapter or external batteries Battery Charge Indicator LED Slots for Secure Digital (SD) memory cards 5
6 Connectivity Fig. 2 Secure access to measurement data from anywhere Measurement Partner Field App (ios/android) 2250-L Hand-held Analyzer 3G/4G/WLAN SD WLAN Measurement Partner Cloud/Internet Measurement Partner Suite (PC) Direct connection: USB, LAN or modem Remote Internet Communication Access your data from anywhere by using various technologies. Type 2250-L allows direct operation through WiFi, modem connection (for example, 3G), or LAN (Ethernet). Measurement Partner Cloud (MP Cloud) Take advantage of modern cloud capability with 2250 Light. The analyzers can communicate with MP Cloud via WiFi, mobile connection or LAN (Ethernet). Upload your measurement data directly to MP Cloud for merging in Measurement Partner Suite with annotations collected with Measurement Partner Field App. Store your data safely and securely in MP Cloud and share Cloud archives with anyone on the planet Measurement Partner Community and Learning Centre Brüel & Kjær understands that our users sometimes need support immediately and at any time of the day. Therefore, we are also offering online support, where you can access it 24/7 and get the help you need. The Measurement Partner learning centre provides access to manuals, guidelines, videos and training courses, all designed to help you get the most out of your hand-held analyzer and noise monitoring software. You will also find help on software applications as well as general noise measurement techniques. The Measurement Partner online community enables you to connect with thousands of hand-held analyzer users from around the world. The community gives you an opportunity to share your experiences with other hand-held analyzer and Measurement Partner Suite users, and to provide help to other members of the community on any aspect of sound and vibration measurement. Visit the Measurement Partner Community and Learning Centre. 6
7 Post-processing Software Fig. 3 Measurement Partner Suite BZ-5503 Measurement Partner Suite BZ-5503, in its basic configuration, comes with your hand-held analyzer (see Product Data BP 2430). It is Brüel&Kjær's state-ofthe-art data viewing and postprocessing toolbox for environmental noise and vibration. Annotating your Measurement Data The free, basic configuration provides data archive, preview and export capabilities, software maintenance and online display. Archives can be stored locally, on network drives or, alternatively, in MP Cloud for easy sharing with anyone on the planet. Measurement Partner Suite also merges field app annotations with the corresponding instrument project. Additional valuable data analysis and post-processing tools are available on a time-limited subscription basis. You only pay for what you need, when you need it, with no penalty should your subscription lapse. Measurement Partner Field App is the recommended solution for on-site annotation of your measurement data. Measurement Partner Field App Measurement Partner Field App transforms the way you work with your hand-held analyzer. It is an advanced companion app for the sound and vibration professional offering: Remote analyzer control Remote display Remote annotation of measurement data Cloud support Whenever you stand next to your analyzer to operate it, you disturb the sound field. Therefore, we have released a field app that lets you stay away from your analyzer. Once your analyzer is powered on, you can wirelessly connect to it using Micro USB Wi-Fi Dongle UL-1050 for G4, Ethernet CF Card UL-1019 for G3. Fig. 4 View and edit annotations collected with the field app Once connection is made to the analyzer, you are ready to start, stop and pause your measurement from a safe distance. During noise measurements, the instantaneous LAF profile is displayed on the field app. This allows you to keep an eye on the status of your measurement without being close to the analyzer. This is particularly important when low noise levels are being measured such as for indoor measurements. MP Field App supports notes, voice commentary, image, video and GPS annotations. All annotations can be uploaded to MP Cloud for merging with the project in Measurement Partner Suite. 7
8 Uploading Measurement Data to Measurement Partner Cloud Type 2250-L can send measurement data to Measurement Partner Cloud (MP Cloud) where projects are immediately available for post-processing, sharing or storage subject to account capacity. Only authorized users have access to the data when it is the MP Cloud. You can create a Cloud account by visiting the MP Cloud web service at cloud.bksv.com. You open an account, register your analyzer serial numbers and perform a one-time pairing of analyzer and account, ensuring data security. You can also administer access to the account from the web service and order subscriptions to increase account capacity. You can connect the hand-held analyzer to the internet through modem, LAN or Wi-Fi connected to router. In the field, the analyzer can connect through Wi-Fi to hotspot on a smart device (Wi-Fi using CFcard UL-1019 for G1-G3 and Micro-USB UL-1050 for G4, respectively). After measurement is completed and the project is saved, you log the analyzer into the cloud, and projects are uploaded to the cloud from the analyzer. To do this, you simply need to move your data to the Cloud folder, which is automatically created when you log on to your account. The data will now be ready for post-analysis in Measurement Partner Suite by anyone who has access to the relevant Cloud archive. Sound Level Meter Software for Type 2250-L BZ-7130 Fig. 5 The large numeric display ideal for a spot noise enforcement check Type 2250-L comes with Sound Level Meter Software for Type 2250-L included. Type 2250-L is a versatile broadband sound level meter that complies with the latest international standard (IEC ) as well as previous international and national standards. All quantities are measured simultaneously. For example, A and C frequency weighted levels are measured at the same time and F, S and I time weightings are applied in parallel, and Peak levels are also measured. Full statistics are also computed on-the-fly. Combine this with the dynamic range exceeding 120 db and never miss a beat! You get all the parameters in one attempt, under- range is non-existent and you will have difficulties provoking an overload. A full complement of occupational health sound parameters are provided simultaneously, complying with national and international standards. The detailed list of available parameters can be found in the specifications section. You choose what you want on the display, but, at any time during or after the measurement all other parameters can be inspected and reported. 8
9 1/1- and 1/3-octave Frequency Analysis Software for Type 2250-L BZ-7131 and BZ-7132 Fig. 6 Example of 1/1-octave frequency analysis. Note that two spectra are displayed simultaneously 1/1-octave Frequency Analysis Software for Type 2250-L BZ-7131, and 1/3-octave Frequency Analysis Software for Type 2250-L BZ-7132 are optional software modules that enable real-time measurements in 1/1- or 1/3-octave bands over a wide frequency range. This makes it a simple matter to obtain spectra in order to, for example, select hearing protection, qualify heat and ventilation systems, or assess tonality. Fig. 7 Tone Assessment BZ-7231 showing 1/3-octave bands with audible tones over a set limit (identified by the blue dot) Tone Assessment BZ-7231 The following frequency ranges are available: 1/1-octave spectra (centre frequencies 16 Hz to 8 khz) 1/3-octave spectra (centre frequencies 12.5 Hz to 16 khz) Each band provides unrivalled dynamic range from the noise floor in that particular band to 140 db. That is, a dynamic range generally in excess of 135 db. Spectra can be A-, B-, C- or Z-weighted. Five spectra are measured and stored and, in addition, two instantaneous spectra are available for display, for example, a minimum and maximum spectrum, that can be superimposed on the display. All the broadband quantities measured by Sound Level Meter Software BZ-7130 are computed in parallel with the frequency analysis. Tone Assessment (optional application) identifies any 1/3-octave bands with audible tones above a set limit. The assessment is based on the band s prominence versus adjacent bands. The adjustment is the penalty to add to L Aeq. Annoying tones in the spectrum can be assessed according to the ISO 1996 standard. The level of each 1/3-octave band is compared to the level of its neighbours, and all tones as well as the overall penalty (adjustment) are indicated. The search parameters are user adjustable to suit national requirements. Logging Software for Type 2250-L BZ-7133 Fig. 8 Display showing part of a logging profile and an exclude marker With optional Logging Software enabled, Type 2250-L becomes a versatile instrument for obtaining time histories. The Logging Software allows you to select freely among the broadband parameters and log them at intervals from 1 s to 24 h. At the same time L AF, L AS and L Aeq can be logged at 100 ms intervals. If Frequency Analysis Software BZ-7131 or BZ-7132 is enabled, the Logging Software additionally lets you log spectra at the same 1 s to 24 h intervals. Logging Software BZ-7133 incorporates a number of features designed to make difficult field work as manageable as possible. 9
10 Signal Recording Option BZ-7226 Some of these features are: Five user-definable markers can be set on-the-fly, making it easy to clearly indicate specific noise sources Markers can be set directly on the profile display using the stylus and the touch screen. Simply tap and drag on the part of the profile you want to mark and select a marker from the drop-down list Markers can even be set after the fact. The display covers the latest 100 samples (100 s of profile when logging at 1 s intervals, otherwise more), so in most cases, you can wait for the event (or disturbance) to end before placing your marker. Alternatively, scroll back in the profile and set your marker Browse easily between markers (like signal recordings) The profile display can be frozen at any time (automatic when you tap the screen) All markers and annotations are saved with the measurement. No further bookkeeping is required. When importing data into Measurement Partner Suite BZ-5503 for further analysis, markers, as well as annotations, are directly accessible on the profile. Charge Injection Calibration (CIC) Measurement integrity is vital, particularly if the system is operating unattended. CIC provides a means of auto-checking the measurement system for 10 s to ensure its continued and accurate operation. With the Logging software, CIC can be set to run at the beginning and end of measurement. Signal Recording Option BZ-7226 works with all other applications. In all cases it allows you to make recordings of the actual measured signal. Recordings are automatically attached to the measurement and kept with it, even after transfer of the data to a PC. One purpose of the Signal Recording Option is to let you record the measurement signal in order to identify and document sound sources. Automatic gain control is available to allow for any signal level. For example: Did the measured L Aeq at 57 db actually stem from the rather distant compressor, or from other sources such as nearby birds or traffic? Not necessarily easy to evaluate on site, very difficult to document convincingly later. If the signal is recorded: No discussion Is it really true that this noise is impulsive and should be penalized accordingly? If the signal is recorded: There may still be a discussion, but it is then based on facts Another important use of signal recording is to record the signal for later processing, such as analysing an engine run-up or a machinery process cycle. With Sound Level Meter Software BZ-7130 and Frequency Analysis Software BZ-7131, Signal Recording Option BZ-7226 lets you: Record all or parts of the measured signal giving rise to specific results, levels and spectra Set up your analzer so that recording can be set to start automatically when the measurement is started, or you can initiate recordings manually With Logging Software BZ-7133, signal recording can be associated with the Event Marker using the Event key or an external signal (such as with Hand Switch ZH-0680, see Ordering Information). The sound during the event is recorded and attached to the appropriate part of the profile. In all of the above cases, the maximum duration of recordings can be set (the analyzer is only limited by available storage on the memory card currently in use). Recording signals may require large amounts of storage; therefore, Signal Recording Option BZ-7226 allows you to decide on the trade-off between storage needed and recording quality (sampling rate). The Signal Recording Option offers a choice of 24- or 16-bit recording. You can use 24-bit recording to capture the full 120 db dynamic range of Type 2250-L, which is convenient for later signal analysis. You can use 16-bit recording to consume less memory; however, this requires selecting the level range for recording (or using the automatic gain control). 10
11 Adding Weather Parameters to Your Measurement Data Fig. 9 Hand-held analyzer measuring outdoor noise using Weather Station Kit MM-0316-A Weather conditions affect the propagation of sound, so wind speed and direction must be taken into account when measuring noise outdoors. Consequently, most environmental noise measurement standards define limits for wind speed and direction. To identify the portions of your measurement that are within allowable limits for wind speed and direction, use Weather Station Kit MM-0316-A (two parameters) or MM-0256-A (six parameters). Fig. 10 Weather Station Kit MM-0316-A The weather stations are based on ultrasound technology and operate well above the upper frequency limit of the microphone. Connect your weather station to your analyzer, turn it on, and you are ready to start measuring with no software setup necessary. The weather station is powered by the analyzer s battery, so there is no need for extra batteries. Post-processing of Weather Data Noise and weather parameters are captured simultaneously on the analyzer and are available for display and post-processing in Measurement Partner Suite BZ-5503 along with your noise data when you are back in the office. To quickly identify the portions of your logging profile where wind speed and direction are within the allowed limits, use Measurement Partner's report and marker wizard (requires license BZ-5503-A). Outdoor Protection For outdoor environmental noise measurements, your analyzer may need extra weather protection, offered by All-weather Case Type 3535-A and Outdoor Microphone Type For details, please refer to Product Data BP 2251 and Product Data BP 2099 respectively. 11
12 Overview of Type 2250-L Software Features The table that follows presents a summary of the features of each of the software modules available with Type 2250-L. See Specifications for details. Feature SLM Software 1/1-oct. Frequency Analysis Software 1/3-oct. Frequency Analysis Software Logging Software IEC/ANSI SLM standards Type/Class db Dynamic Range no need for range switching Sound levels up to 140 db with supplied Microphone Type 4950 Frequency weightings A, B, C, Z (linear) and time weightings F, S, I Free-field/diffuse-field correction Preset time start/stop Multi-language user interface Context-sensitive help Broadband statistics based on L Aeq, L AF or L AS Broadband frequency range: 5 Hz 20 khz Remote control using analog or GSM modem Transfer of data files while measuring (USB, LAN or modem) Recording of measured signal during measurement, 16- or 24-bit * * * * Timers for automatic measurement start * * * * Occupational health parameters Weather data and GPS input Back-erase last 5 seconds of measurement data Tone assessment Loudness and Noise Rating results 1/1-octave spectra (centre frequencies 16 Hz 8 khz) 1/3-octave spectra (centre frequencies 12.5 Hz 16 khz) Charge Injection Calibration (CIC) Recording of signal during noise events (with Event key or external signal) Logging of all or selected broadband parameters and spectra Logging period 1s 24h, Logging time up to 31 days L Aeq, L AS, L AF logged every 100 ms Profile display Profile overview of entire measurement Markers on profile display * If Signal Recording Option is enabled If 1/1- or 1/3-octave Frequency Analysis Software is enabled * * 12
13 Compliance with Environmental Standards The CE marking is the manufacturer's declaration that the product meets the requirements of the applicable EU directives RCM mark indicates compliance with applicable ACMA technical standards that is, for telecommunications, radio communications, EMC and EME China RoHS mark indicates compliance with administrative measures on the control of pollution caused by electronic information products according to the Ministry of Information Industries of the People s Republic of China WEEE mark indicates compliance with the EU WEEE Directive Safety EN/IEC , ANSI/UL and CSA C22.2 No : Safety requirements for electrical equipment for measurement, control and laboratory use EMC Emission EN/IEC : Generic emission standard for residential, commercial and light industrial environments EN/IEC 61326: Electrical equipment for measurement, control and laboratory use EMC requirements CISPR 22: Radio disturbance characteristics of information technology equipment. Class B Limits IEC , IEC 61260, IEC and IEC 60804: Instrumentation standards Note: The above is only guaranteed using accessories listed in this Product Data EMC Immunity EN/IEC : Generic standard Immunity for industrial environments EN/IEC 61326: Electrical equipment for measurement, control and laboratory use EMC requirements IEC , IEC 61260, IEC and IEC 60804: Instrumentation standards Note: The above is only guaranteed using accessories listed in this Product Data Temperature IEC & IEC : Environmental Testing. Cold and Dry Heat. Operating Temperature: 10 to +50 C (14 to 122 F) Storage Temperature: 25 to +70 C ( 13 to 158 F) Humidity IEC : Damp Heat: 93% RH (non-condensing at +40 C (104 F)). Recovery time 2 4hours Mechanical Non-operating: IEC : Vibration: 0.3 mm, 20 m/s 2, Hz IEC : Bump: 1000 bumps at 400 m/s 2 IEC : Shock: 1000 m/s 2, 6 directions Enclosure IEC (1989): Protection provided by enclosures: IP44 * * With preamplifier, extension cable or protection plug connected to the top socket and the hinged cover protecting the bottom connectors Additional Standards for Micro USB Wireless Adaptor UL-1050 * Safety EMC Emission Spectrum & Health Restriction of Hazardous Substances EN :2006+A11:2009+A1:2010 +A12:2011 EN V1.9.2 EN V2.2.1 EN 55022: 2010+AC:2011 EN V1.7.1 EN 62311:2008 EN 50581:2012 FCC Grant of Equipment Authorization for Micro USB Wireless Adaptor UL-1050 * FCC Identifier KA2WA121A1 FCC Rule Parts 15c Frequency Range (MHz) Output Watts EC Declaration 1Tx1R bgn USB adapter of Conformity C-Tick AS/NZS 4268: 2008+A1:2010 Authorization * From the D-Link Corporation declaration of conformance for Wireless N 150 Micro USB Adaptor DWA
14 Specifications Hand-held Analyzer Type 2250-L (2250 Light) Platform Specifications apply to 2250 Light fitted with Microphone Type 4950 and Microphone Preamplifier ZC-0032: Microphone SUPPLIED MICROPHONE Type 4950: Prepolarized Free-field ½ Microphone Nominal Open-circuit Sensitivity: 50 mv/pa (corresponding to 26 db re 1 V/Pa) ±2 db Capacitance: 12.5pF (at 250Hz) MICROPHONE PREAMPLIFIER ZC-0032 Nominal Preamplifier Attenuation: 0.3 db Connector: 10-pin LEMO Extension Cables: Up to 100 m in length between the microphone preamplifier and 2250 Light, without degradation of the specifications MICROPHONE POLARIZATION VOLTAGE Selectable between 0 V and 200 V SELF-GENERATED NOISE LEVEL Typical values at 23 C for nominal microphone open-circuit sensitivity: Weighting Microphone Electrical Total A 14.0 db 12.7 db 16.4 db B 12.9 db 11.9 db 15.4 db C 13.0 db 13.6 db 16.3dB Z 5Hz 20kHz 14.4 db 19.3 db 20.5 db Interface KEYBOARD Pushbuttons: 11 keys with backlight, optimized for measurement control and screen navigation ON-OFF BUTTON Function: Press 1 s to turn on; press 1 s to enter standby; press for more than 5 s to switch off STATUS INDICATORS LEDs: Red, amber and green DISPLAY Type: Transflective back-lit touch screen, dot matrix Black and white scheme Backlight: Adjustable level and on-time USER INTERFACE Measurement Control: Using pushbuttons on keyboard Setup and Display of Results: Using stylus on touch screen or pushbuttons on keyboard Lock: Keyboard and touch screen can be locked and unlocked USB INTERFACE USB 2.0 OTG Micro AB and USB 2.0 Standard A sockets for Wi-Fi Dongle UL-1050, printer or weather station MODEM INTERFACE Connection to Internet through GPRS/EDGE/HSPA modem connected through: The USB Standard A Socket Supports DynDNS for automatic update of IP address of host name PRINTER INTERFACE PCL printers, Mobile Pro Spectrum thermal printer or Seiko DPU S245/S445 thermal printers can be connected to USB socket Inputs/Outputs SECURE DIGITAL SOCKET 2 SD sockets Connect SD and SDHC memory cards LAN INTERFACE SOCKET Connector: RJ 45 Auto-MDIX Speed: 100 Mbps Protocol: TCP/IP TRIGGER SOCKET Connector: Triaxial LEMO Max. Input Voltage: ±20 Vpeak Input Impedance: >47 kω Precision: ±0.1 V HEADPHONE SOCKET Connector: 3.5 mm Minijack stereo socket Max. Peak Output Level: ±1.4 V Output Impedance: 32 Ω in each channel Power EXTERNAL DC POWER SUPPLY REQUIREMENTS Used to charge the battery pack in the analyzer Voltage: 8 24 V DC, ripple voltage <20 mv Current Requirement: min. 1.5 A Power Consumption: <2.5 W, without battery charging, <10 W when charging Cable Connector: LEMO Type FFA.00, positive at centre pin EXTERNAL AC MAIN SUPPLY ADAPTOR Part No.: ZG-0426 Supply Voltage: 100 to 120/200 to 240 VAC; 47 to 63 Hz Connector: 2-pin IEC 320 BATTERY PACK Rechargeable Li-Ion battery Part No.: QB-0061 Voltage: 3.7 V Capacity: 5200 mah nominal Typical Operating Time: >11 h (screen backlight dimmed); >10 h (full screen backlight) Use of external interfaces (LAN, USB, Wi-Fi) will decrease battery operating time. Connecting a weather station or a GPS receiver can decrease battery operating with up to 20%. Connecting Wireless Adaptor UL-1050 can decrease battery operating time up to 35% Battery Cycle Life: >500 complete charge/discharge cycles Battery Indicator: Remaining battery capacity and expected working time may be read out in % and time Battery Fuel Gauge: The battery is equipped with a built-in fuel gauge, which continuously measures and stores the actual battery capacity in the battery unit Charge Time: In analyzer, typically 10 hours from empty at ambient temperatures below 30 C (86 F). To protect the battery, charging will be terminated completely at ambient temperatures above 40 C (104 F). At 30 to 40 C, charging time will be prolonged. With External Charger ZG-0444 (optional accessory), typically five hours Note: It is not recommended to charge the battery at temperatures below 0 C (32 F) or over 50 C (122 F). Doing this will reduce battery lifetime CLOCK Back-up battery powered clock. Drift <0.45 s per 24-hour period Storage INTERNAL FLASH-RAM (NON-VOLATILE) 512 Mbyte for user setups and measurement data 14
15 EXTERNAL MEMORY CARD Secure Digital (SD and SDHC) Card: For store/recall of measurement data USB MEMORY STICK For store/recall of measurement data Environmental WARM-UP TIME From Power Off: <2 minutes From Standby: <10 seconds WEIGHT AND DIMENSIONS 650 g (23 oz) including rechargeable battery mm ( ) including preamplifier and microphone User Interface PREFERENCES Date, Time and Number formats can be specified LANGUAGE User Interface in Catalan, Chinese (People s Republic of China), Chinese (Taiwan), Croatian, Czech, Danish, English, Flemish, French, German, Hungarian, Japanese, Italian, Korean, Polish, Portuguese, Romanian, Russian, Serbian, Slovenian, Spanish, Swedish, Turkish and Ukrainian HELP Concise context-sensitive help in Chinese (People s Republic of China), English, French, German, Italian, Japanese, Polish, Romanian, Serbian, Slovenian, Spanish and Ukrainian UPDATE OF SOFTWARE Update to any version using BZ-5503 through USB or update via Internet: any version from 4.0 and up REMOTE ACCESS Connect to the analyzer using Measurement Partner Suite BZ-5503, using Measurement Partner Field App (ios or Android smartphone app), using the 2250/2270 SDK (Software Development kit), using a REST interface through HTTP, or using an Internet browser supporting JavaScript. The connection is password protected Two levels of protection: Guest level: for viewing only Administrator level: for viewing and full control of the analyzer CLOUD Connect to Measurement Partner Cloud on cloud.bksv.com for transferring data to an archive in the cloud for storage or easy synchronization with Measurement Partner Suite BZ-5503 WIRELESS Specifications apply to Wireless USB Adaptor UL-1050 Operating Frequency: 2.4 GHz Data Rate: IEEE n: up to 150 Mbps IEEE g: up to 54 Mbps IEEE b: up to 11 Mbps Encryption/Authentication: 64/128-bit WEP WPA-PSK WPA2-PSK Range: The range is similar to a standard WLAN unit, typically from 10 to 50 m (33 to 164 ft), depending on the environment and the number of other WLAN transmitters in the area (smartphones, Wi-Fi, etc.) Power Requirements: Power Consumption: <1 W Software Specifications Sound Level Meter Software for 2250 Light BZ-7130 Conforms with the following National and International Standards: IEC (2013) Class 1 IEC (1979) plus Amendment 1 ( ) and Amendment 2 ( ), Type 1 IEC ( ), Type 1 DIN ( ) ANSI S plus ANSI S1.4 A 1985 Amendment, Type 1 ANSI S , Type 1 Note: The International IEC Standards are adopted as European standards by CENELEC. When this happens, the letters IEC are replaced with EN and the number is retained. Type 2250-L also conforms to these EN Standards Input CORRECTION FILTERS For Microphone Types 4950, 4952, 4952+EH-2152 and 4184-A: Correct the frequency response to compensate for sound field and accessories Accessories (Type 4950 only): None or Windscreen UA-0237 Sound Field: Free-field or Diffuse-field (for Types 4952 and 4184-A only: 0 (Top) reference direction and 90 (Side) reference direction) Analysis DETECTORS Parallel Detectors: On every measurement: A- or B-weighted: (Switchable) broadband detector channel with three exponential time weightings (Fast, Slow, Impulse), one linearly averaging detector and one peak detector C- or Z-weighted: (Switchable) as for A- or B-weighted Overload Detector: Monitors the overload outputs of all the frequency weighted channels MEASUREMENTS X=frequency weightings A or B Y = frequency weightings C or Z V = frequency weightings A, B, C or Z U = time weightings F or S Q = exchange rate 4, 5 or 6 db N = number between 0.1 and 99.9 For Storage: Full statistics For Display and Storage: Start Time Stop Time Overload % Elapsed Time L Xeq L Yeq L XE L YE L Ceq L Aeq L XSmax L XFmax L XImax L YSmax L YFmax L YImax L XSmin L XFmin L XImin L YSmin L YFmin L YImin L XIeq L YIeq L AIeq L Aeq L AFTeq L AFTeq L Aeq Time Remaining L ep,d L ep,d,v E Dose Proj. Dose #VPeaks (>NNNdB) #VPeaks (>137dB) #VPeaks (>135dB) L Vpeak T Vpeak L avuq TWA TWA v DoseUQ Proj. DoseUQ L Aeq,T1,mov,max L Aeq,T2,mov,max L Ceq,T1,mov,max L Ceq,T2,mov,max ΔL eq,t1,mov,max ΔL eq,t2,mov,max Weather Data (requires connection to a weather station): Wind Dir. avg. Wind Dir. min. 15
16 Wind Dir. max. Wind Speed avg. Wind Speed min. Wind Speed max. Amb. Temperature Amb. Humidity Amb. Pressure Rainfall Only for Display as Numbers or Quasi-analog Bars: L XS L XF L XI L YS L YF L YI L XS(SPL) L XF(SPL) L XI(SPL) L YS(SPL) L YF(SPL) L YI(SPL) L Vpeak,1s L AN1 or L AUN1 L AN2 or L AUN2 L AN3 or L AUN3 L AN4 or L AUN4 L AN5 or L AUN5 L AN6 or L AUN6 L AN7 or L AUN7 Std.Dev. L Aeq,T,mov L Aeq,T2,mov L Ceq,T1,mov L Ceq,T2,mov ΔL eq,t1,mov ΔL eq,t2,mov Trig. Input Voltage Instantaneous Weather Data: Wind Dir. Wind Speed Instantaneous GPS Data: Latitude Longitude MEASURING RANGES When using Microphone Type 4950 Dynamic Range: From typical noise floor to max. level for a 1 khz pure tone signal, A-weighted: 16.4 db to 140 db Primary Indicator Range: In accordance with IEC 60651, A-weighted: 23.6 db to db Linearity Range: In accordance with IEC 60804, A-weighted: 21.5 db to db Linear Operating Range: In accordance with IEC 61672: A-weighted 1 khz: 24.9 db to db C-weighted: 26.2 db to db Z-weighted: 31.6 db to db Peak C Range: In accordance with IEC 61672: 1 khz, 43.0 db to db SAMPLING FOR BROADBAND STATISTICS Statistics can be based on either L AF, L AS or L Aeq : Statistics L AFN1 7 or L ASN1 7 are based on sampling L AF or L AS, resp., every 10 ms into 0.2 db wide classes over 130 db Statistics L AN1 7 are based on sampling L Aeq every second into 0.2 db wide classes over 130 db Full distribution saved with measurement The Std.Dev. (Standard Deviation) parameter is calculated from the Statistics Measurement Display and Control MEASUREMENT DISPLAYS Measurement data displayed as numbers of various sizes and one quasi-analog bar. Measured data are displayed as db values, housekeeping data as numbers in relevant format. Instantaneous measurement L XF is displayed as a quasi-analog bar MEASUREMENT CONTROL Manual: Manually controlled single measurement Automatic: Preset measurement time from 1 s to 24 hr in 1 s steps Manual Controls: Reset, Start, Pause, Back-erase, Continue and Store the measurement manually Auto-start: A total of 10 timers allow set up of measurement start times up to a month in advance. Each timer can be repeated. Measurements are automatically stored when completed BACK-ERASE The last 5 s of data can be erased without resetting the measurement Measurement Status ON SCREEN Information such as overload and running/paused are displayed on screen as icons TRAFFIC LIGHTS Red, yellow and green LEDs show measurement status and instantaneous overload as follows: Yellow LED flash every 5 s = stopped, ready to measure Green LED flashing slowly = awaiting calibration signal Green LED on constantly = measuring Yellow LED flashing slowly = paused, measurement not stored Red LED flashing quickly = intermittent overload, calibration failed NOTIFICATIONS Sends an SMS or daily at a specified time or if an alarm condition is fulfilled. Alarm Conditions: Disk space below set value Internal battery enters set state Change in measurement state Reboot of analyzer Calibration Initial calibration is stored for comparison with later calibrations ACOUSTIC Using Sound Calibrator Type 4231 or custom calibrator. The calibration process automatically detects the calibration level when Sound Calibrator Type 4231 is used ELECTRICAL Uses internally generated electrical signal combined with a typed-in value of microphone sensitivity CALIBRATION HISTORY Up to 20 of the last calibrations made are listed and can be viewed on the analyzer Signal Monitoring The input signal can be monitored using an earphone/headphones connected to the headphone socket HEADPHONE SIGNAL Input signal can be monitored using this socket with headphones/earphones Gain Adjustment: 60 db to 60 db GPS Annotations A text annotation with GPS information can be attached (Latitude, Longitude, Altitude and position error). Requires connection to a GPS receiver Data Management PROJECT TEMPLATE Defines the display and measurement settings. Setups can be locked and password protected PROJECT Measurement data stored with the project template JOB Projects are organized in jobs Explorer facilities for easy management of data (copy, cut, paste, delete, rename, view data, open project, create job, set default project name) 16
17 Software Specifications 1/1-octave Frequency Analysis Software for 2250 Light BZ-7131 and 1/3-octave Frequency Analysis Software for 2250 Light BZ-7132 The specifications for BZ-7131 and BZ-7132 include the specifications for Sound Level Meter Software for 2250 Light BZ BZ-7131 and BZ-7132 add: Standards Conforms with the following National and International Standards: IEC (2014), 1/1-octave Bands and 1/3-octave Bands, Class 1 IEC ( ) plus Amendment 1 ( ), 1/1-octave Bands and 1/3-octave Bands, Class 0 ANSI S , 1/1-octave Bands and 1/3-octave Bands, Order 3, Type 0 C ANSI S , 1/1-octave Bands and 1/3-octave Bands, Class 0 ANSI/ASA S Part 1, 1/1-octave Bands and 1/3-octave Bands, Class 1 Frequency Analysis CENTRE FREQUENCIES 1/1-octave Band Centre Frequencies (BZ-7131 only): 16 Hz to 8 khz 1/3-octave Band Centre Frequencies (BZ-7132 only): 12.5 Hz to 16 khz MEASUREMENTS X = frequency weightings A, B, C or Z Spectra for Display and Storage: L Xeq L XSmax L XFmax L XSmin L XFmin Spectra for Display Only: L XS L XF Single Values: SIL PSIL SIL3 L Xeq (f1 f2) * NR NR Decisive Band RC RC Classification NCB NCB Classification NC NC Decisive Band Loudness Loudness Level (BZ-7132 only) * where f1 and f2 are frequency bands in the spectrum MEASURING RANGES When using Microphone Type 4950: BZ-7131, 1/1-octave: Dynamic Range: From typical noise floor to max. level for a pure tone signal at 1 khz: 5.9 to 140 db Linear Operating Range: In accordance with IEC 61260: 22.9 db to 140 db BZ-7132, 1/3-octave: Dynamic Range: From typical noise floor to max. level for a pure tone signal at 1 khz: 1.0 to 140 db Linear Operating Range: In accordance with IEC 61260: 20.1 db to 140 db MEASUREMENT DISPLAYS Spectrum: One or two spectra superimposed + A/B and C/Z broadband bars Table: One or two spectra in tabular form Y-axis: Range: 5, 10, 20, 40, 60, 80, 100, 120, 140 or 160 db. Auto zoom or auto scale available Cursor: Readout of selected band Software Specifications Logging Software for 2250 Light BZ-7133 The specifications for BZ-7133 include the specifications for Sound Level Meter Software for 2250 Light BZ BZ-7133 adds: Logging MEASUREMENTS Measurement data logged at preset periods into files on: SD Card USB Memory Stick Logging Period: From 1 s to 24 hr with 1 s resolution Fast Logging: L AF, L AS and L Aeq can be logged every 100 ms, irrespective of logging period Broadband Data Stored at each Logging Interval: All, or up to 10 selectable broadband data including weather data and L Aeq,T,mov Broadband Statistics Stored at each Logging Interval: Full distribution, or none Spectrum Data Stored at each Logging Interval: All, or up to three selectable spectra (license for BZ-7131 or BZ-7132 required) Logging Time: From 1 s to 31 days with 1 s resolution Measurement Total: For the logging time, in parallel with logging: All broadband data, statistics and spectra (license for BZ-7131 or BZ-7132 required). Automatic reboot and resume of operation in case of power failure MEASUREMENT DISPLAYS Profile: Graphical display of selectable measurement data versus time. Fast display of next or previous marker; Profile overview of entire measurement Y-axis: Range: 5, 10, 20, 40, 60, 80, 100, 120, 140 or 160 db. Auto zoom or auto scale available X-axis: Scroll facilities Cursor: Readout of measurement data at selected time MARKERS Five user-definable markers for online marking of noise sources or events anywhere in the profile. Markers are set using the stylus on the touch screen, or the three marker pushbuttons Calibration CHARGE INJECTION CALIBRATION (CIC) Injects an internally generated electrical signal in parallel with the microphone diaphragm. A manual CIC can be performed whenever there is no measurement in progress. An automatic CIC can be performed at the start and end of a logging measurement Notifications ALARM CONDITIONS CIC failed (in addition to those specified for BZ-7130) Weather Data MM-0256-A WEATHER STATION KIT Six parameters: Wind Speed, Wind Direction, Ambient Temperature, Ambient Humidity, Ambient Pressure, Rain Gauge) MM-0256-A WEATHER STATION KIT Two parameters: Wind Speed, Wind Direction 17
18 Software Specifications Signal Recording Option BZ-7226 Signal Recording Option BZ-7226 is enabled with a separate license. It works with all the software for Type 2250-L: Sound Level Meter, Frequency Analysis and Logging Software For data storage, Signal Recording requires: SD Card USB Memory Stick RECORDED SIGNAL A-, B-, C- or Z-weighted signal from the measurement transducer AUTOMATIC GAIN CONTROL The average level of the signal is kept within a 40 db range, or the gain can be fixed SAMPLING RATE AND PRE-RECORDING The signal is buffered for the pre-recording of the signal. This allows the beginning of events to be recorded even if they are only detected later. Sampling Rate (khz) Maximum Pre-recording (s) 16-bit Maximum Pre-recording (s) 24-bit Memory (KB/s) 16-bit Memory (KB/s) 24-bit PLAYBACK Playback of signal recordings can be listened to using the earphone/headphones connected to the headphone socket RECORDING FORMAT The recording format is either 24- or 16-bit wave files (extension.wav) attached to the data in the project, easily played-back afterwards on a PC using BZ-5503, Type 7820 or Type Calibration information is stored in the WAV file, allowing BZ-5503 and Brüel & Kjær s PULSE Multi-analyzer to analyse the recordings Functions with BZ-7130 and BZ-7131 Manual Control of Recording: Recording can be manually started and stopped during a measurement using a pushbutton or an external signal Automatic Control of Recording: Start of recording when measurement is started. Minimum and Maximum recording time can be preset Functions with BZ-7133 Manual Control of Recording (using Manual Event or Back-erase pushbutton, or an external signal): Recording during all of the event, or for preset minimum and maximum duration. A Sound marker is set while recording. Selectable pre- and post-recording time Manual Control of Recording (using touch screen): Recording for the selected time period (subject to the limitations of the pre-recording buffer). A Sound marker is set for the selected time period Automatic Control of Recording: Recording during all of the event or for preset minimum and maximum duration. Selectable pre- and postrecording time Playback: Playback of signal recordings can be listened to using earphone/headphones connected to the headphone socket Gain Adjustment: 60 db to 60 db Software Specifications Tone Assessment Option BZ-7231 LICENSE Tone Assessment Option BZ-7231 is enabled with a separate license and can be used with the 1/3-octave and logging template (BZ-7132 and BZ-7133) TONE ASSESSMENT Tone assessment is based on the measured 1/3-octave spectrum in accordance with either the international ISO 1996:2007 Acoustics Description, assessment and measurement of environmental noise part 2: Determination of environmental noise levels. Annex D (informative) Objective method for assessing the audibility of tones in noise Simplified method SPECTRA ASSESSED The displayed 1/3-octave spectrum (L eq ) may be assessed. Assessment is made as post-processing, that is, when measurement is paused or stopped SETUP ACCORDING TO STANDARD Setups in violation of the standard are indicated as such on the display. You can then accept to apply the default setup. Tone assessment will be made if possible, in spite of standard violations. For tone assessment according to ISO , Annex D, you can set the division between the Low and Middle frequency range, the division between the Middle and High frequency range, and the limits for the level differences between adjacent bands RESULTS Tones are indicated above the spectrum when Tone is selected as spectrum parameter. The resulting adjustment can be viewed on the Value panel. It is not saved with the measurement QUALITY INDICATORS On the display, a quality indicator (smiley) will indicate that a hint is available for tone assessment quality. Click on the indicator to see the hint Specifications Measurement Partner Suite BZ-5503 BZ-5503 is included with 2250 Light for easy synchronization of data between PC and 2250 Light. BZ-5503 is supplied on DVD BZ-5298 PC REQUIREMENTS Operating System: Windows 7, 8 or 8.1 (all in 32-bit or 64-bit versions) Recommended PC: Intel Core i3 Microsoft.NET GB of memory Sound card DVD drive At least one available USB port Solid State Drive ONLINE DISPLAY OF 2250 LIGHT DATA Measurements on 2250 Light can be controlled from the PC and displayed online with the PC, using the same user interface on the PC as on 2250 Light Display: ( recommended) DATA MANAGEMENT Explorer: Facilities for easy management of Analyzers, Archives, MP Cloud archives, Jobs and Projects (copy, cut, paste, delete, rename, create) 18
19 Synchronization: Projects can be synchronized between PC and 2250 Light and between local and cloud archives. Measurement Partner Suite merges MP Field App annotations with the corresponding instrument project EXPORT FACILITIES Excel: Projects (or user-specified parts) can be exported to Microsoft Excel Brüel & Kjær Software: Projects can be exported * to Predictor-LimA Type 7810, Acoustic Determinator Type 7816, Evaluator Type 7820, Protector Type 7825 or Qualifier (Light) Type 7830 (7831) POST-PROCESSING Measurement Partner Suite is a suite of modules, including postprocessing tools for data acquired with Type 2250-L. The following post-processing modules are available: Logging Module BZ-5503-A Spectrum Module BZ-5503-B WAV File Analysis Module BZ-5503-C * Not all data are available in all exports. The data exported are dependent on the type and target of the export. These modules help to assess logging data and measured spectra, such as calculating contribution from markers on a logging profile or correcting spectra for background noise. For more information see the Product Data for Measurement Partner Suite, BP LIGHT SOFTWARE UPGRADES AND LICENSES The utility software controls 2250 Light software upgrades and licensing of the 2250 Light applications INTERFACE TO 2250 LIGHT USB, LAN or Internet connection USB Connection: USB ver. 2.0 LANGUAGE User Interface in Chinese (People s Republic of China), Chinese (Taiwan), Croatian, Czech, Danish, English, Flemish, French, German, Hungarian, Japanese, Italian, Korean, Polish, Portuguese, Romanian, Russian, Serbian, Slovenian, Spanish, Swedish, Turkish and Ukrainian HELP Concise context-sensitive help in English Ordering Information Type 2250-L-D10 Hand-held Analyzer with Sound Level Meter Software BZ-7130 Type 2250-L-D20 Hand-held Analyzer with Sound Level Meter Software BZ-7130 and 1/1-octave Frequency Analysis Software BZ-7131 Type 2250-L-D30 Hand-held Analyzer with Sound Level Meter Software BZ-7130, 1/3-octave Frequency Analysis Software BZ-7132 and 1/1-octave Frequency Analysis Software BZ-7132 Type 2250-L-D40 Hand-held Analyzer with Sound Level Meter Software BZ-7130 and Logging Software BZ-7133 Type 2250-L-D50 Hand-held Analyzer with Sound Level Meter Software BZ-7130, 1/1-octave Frequency Analysis Software BZ-7131, 1/3-octave Frequency Analysis Software BZ-7132 and Logging Software BZ-7133 Included with Type 2250-L: Type 4950: Prepolarized Free-field ½ Microphone ZC-0032: Microphone Preamplifier AO-1494: USB Standard A to USB Micro B Interface Cable, for hardware version 4, 1.8 m (6 ft) AO-1476: USB Standard A to USB Mini B Interface Cable for hardware versions 1 3, 1.8 m (6 ft) BZ-5298: Environmental Software DVD, including Measurement Partner Suite BZ-5503 ZG-0426: Mains Power Supply QB-0061: Battery Pack FB-0691: Hinged Cover for Hand-held Analyzer UA-0237: 90 mm dia. Windscreen DH-0696: Wrist Strap KE-0441: Protective Cover for 2250 Light UA-1654: 5 Extra Styli UL-1050: Wireless USB-A (M) Adaptor B/G/N Software and Accessories Available Separately SOFTWARE MODULES BZ /1-octave Frequency Analysis Software for 2250 Light BZ /3-octave Frequency Analysis Software for 2250 Light BZ-7133 Logging Software for 2250 Light BZ-7226 Signal Recording Option BZ-7231 Tone Assessment Option MEASURING Type 3535-A All-weather Case (see Product Data BP 2251) AO-0697-D-030 Microphone Extension Cable, 10-pin LEMO, 3 m (10 ft) AO-0697-D-100 Microphone Extension Cable, 10-pin LEMO, 10 m (33 ft) KE-0440 Travel Bag HT-0015 Earphones UA mm dia. Windscreens (6-pack of UA-0237) UA-0587 Tripod UA-0801 Small Tripod UA-1317 Microphone Holder UA-1651 Tripod Extension for Hand-held Analyzer UL-1009 SD Memory Card for Hand-held Analyzers UL-1013 CF Memory Card for Hand-held Analyzers (for hardware versions 1 3) UL-1017 SDHC Memory Card for Hand-held Analyzers UA-1673 Adaptor for Standard Tripod Mount UA-1251 Lightweight Tripod UA Extra Styli MM-0256-A Weather Station Kit MM-0316-A Weather Station Kit Included with MM-0256-A or MM-0316-A: MM : Six Parameter Weather Station (and mounting kit) MM : Two Parameter Weather Station (and mounting kit) AO-0657: USB Cable AO-0659: Cable M12 8-pin (F) to Lemo 1-B 8-pin (M), 10 m (33.3 ft) BR 1779: Weather Station Field Guide DB-4364: Weather Station Pole Adapter KE-4334: Weather Station Carrying Case QX-0016: Screwdriver QX-1171: 2.5 mm Hex Wrench UA-1707-A: Weather Station Tripod Adaptor ZH-0689: Weather Station USB Adaptor ANALYZER COMPONENTS ZG-0444 Charger for QB-0061 Battery Pack ZH-0680 Hand Switch for remote control CALIBRATION Type 4231 Sound Calibrator (fits in KE-0440) INTERFACING BZ-5503-A Logging Module (see Product Data BP 2430) BZ-5503-B Spectrum Module (see Product Data BP 2430) 19
20 Type 7821 Evaluator Light data viewing and calculation software Type 7825 Protector calculation software of personal noise exposure UL /100 Ethernet CF Card (for hardware versions 1 3) UL-1019 CF WLAN Card for Hand-held Analyzers (for hardware versions 1 3) UL-0250 USB to RS 232 Converter, for hardware version 4 Service Products MAINTENANCE 2250-L-EW1 Extended Warranty, one year extension 2250-L-MU1 Upgrade of 2250 Light to Type 2250, performed at headquarters ACCREDITED CALIBRATION 2250-CAI Accredited Initial Calibration of Type CAF Accredited Calibration of Type CTF Traceable Calibration of Type TCF Conformance Test of Type 2250, with certificate Brüel & Kjær and all other trademarks, service marks, trade names, logos and product names are the property of Brüel & Kjær or a third-party company. ËBP ÆÎ BP Brüel & Kjær. All rights reserved. Brüel & Kjær Sound & Vibration Measurement A/S DK-2850 Nærum Denmark Telephone: Fax: [email protected] Local representatives and service organizations worldwide Although reasonable care has been taken to ensure the information in this document is accurate, nothing herein can be construed to imply representation or warranty as to its accuracy, currency or completeness, nor is it intended to form the basis of any contract. Content is subject to change without notice contact Brüel & Kjær for the latest version of this document.
PRODUCT DATA. Uses and Features
2250 Light has been developed specifically for measuring occupational, environmental and product noise, while complying fully with all the relevant national and international standards. Extensive user
PRODUCT DATA. Hand-held Analyzer Types 2250 and 2270. Uses and Features
PRODUCT DATA Hand-held Analyzer Types 2250 and 2270 Types 2250 and 2270 are innovative, hand-held analyzers from Brüel & Kjær. The analyzers easy, safe and clever design philosophy is based on extensive
PRODUCT DATA. Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) PRODUCT DATA Hand-held Analyzer Types 2250 and 2270 with Sound Level Meter Software BZ-7222, Frequency Analysis Software
PRODUCT DATA. Measurement Partner Suite BZ-5503 from software version 4.6. Uses, Benefits and Features
PRODUCT DATA Measurement Partner Suite BZ-5503 from software version 4.6 Modular and optimized for the post-processing of measurement data, Measurement Partner Suite provides essential postprocessing tools
PRODUCT DATA. 2238 Mediator Class 1 Integrating Sound Level Meters
PRODUCT DATA 2238 Mediator Class 1 Integrating Sound Level Meters When it comes to investing in a sound level meter, it s important to get an instrument that can keep up with you as your measurement requirements
USER MANUAL. Hand held Analyzer Types 2250 and 2270
USER MANUAL Hand held Analyzer Types 2250 and 2270 With Sound Level Meter Software BZ 7222, Frequency Analysis Software BZ 7223, Logging Software BZ 7224, Enhanced Logging Software BZ 7225, Signal Recording
Sound Level Meters Nor131 & Nor132
Product Data Sound Level Meters Nor131 & Nor132 Applications Noise hazards in the workplace Prescription of hearing protection Environmental noise investigations Product noise testing Noise labeling Features
3M Occupational Health & Environmental Safety Division 3M SoundPro Sound Level Meters SE/DL Series. Easy. Functionality
3M Occupational Health & Environmental Safety Division 3M SoundPro Sound Level Meters SE/DL Series Easy to Use Functionality Advanced Sound Level Monitoring The 3M SoundPro Sound Level Meters SE/DL provides
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Telstra Pre-Paid 3G Wi-Fi. This guide will help you get connected as quickly and
Product Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301
Product Data Thermal Comfort Data Logger Type 1221 Including Application Software Type 7301 USES: For measuring all physical parameters necessary to evaluate heat stress and thermal comfort For evaluating
125 8880 telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR
FOR MORE INFORMATIoN: 125 8880 telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR Telstra PRE-paid 4G wi-fi LET S GET THIS SHOW ON THE ROad WHAT S INSIDE Your Telstra Pre-Paid 4G Wi-Fi
Integrating Sound Level Meter and Datalogger
USER GUIDE Integrating Sound Level Meter and Datalogger Model 407780A Introduction Thank you for selecting the Extech Instruments Model 407780A. This device is shipped fully tested and calibrated and,
GPS Vehicle and personal location tracker. User manual
GPS Vehicle and personal location tracker User manual 1 Contents 1. Product overview... 2 2. Safety instruction... 3 3. Specification and parameters... 3 4. Getting started... 4 4.1 Hardware and accessories...
PRODUCT DATA. Human Vibration Analyzer Type 4447
PRODUCT DATA Human Vibration Analyzer Type 4447 Brüel & Kjær's Human Vibration Analyzer Type 4447 is a portable system designed for those who work with human vibration and require quick and reliable results
Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.
17" (43 cm) LCD Monitor Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. Long Distance Transmission Easily
Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
NoiseMeters. www.noisemeters.com. dosebadge. Monitoring Personal Noise Exposure
NoiseMeters dosebadge Monitoring Personal Noise Exposure Small size and weight with simple operation No cables or controls on the dosebadge Reduces damage and tampering Very strong construction Meets IEC
Sound level meters and accessories
PRODUCT OVERVIEW Sound level meters and accessories US customers: buy online at store.bksv.com CONTENTS INTRODUCTION Introduction 3 Sound Calibrator 4231 4 Noise Dose Meter 4448 5 Integrating-averaging
Intel Core i3-2120 processor. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.
VS-8132 Pro+ Hardware Spec. Processor HDD Capacity Intel Core i3-2120 processor 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The system is shipped without HDD. 2. For the HDD compatibility list,
GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G
GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Pre-Paid Telstra Wi-Fi 4G. This guide will help you get connected as quickly and
PA700 Rugged Handheld Computer
PA700 Rugged Handheld Computer User s Manual Version 1.0 Table of content Table of content... 2 1. Package Contents... 3 2. Getting started... 4 2.1 Device overview... 4 2.2 Assembly... 6 Accessing battery,
Noise Monitoring Software, version 7.0 Types 7802 and 7840
PRODUCT DATA Noise Monitoring Software, version 7.0 Types 7802 and 7840 The basic software packages Noise Monitoring Software Types 7802 and 7840 are the central point in any Brüel & Kjær noise monitoring
USER MANUAL. Hand held Analyzer 2250 Light. With Sound Level Meter Software BZ 7130 1/3 oct. Frequency Analysis Software BZ 7132
USER MANUAL Hand held Analyzer 2250 Light With Sound Level Meter Software BZ 7130 1/1 oct. Frequency Analysis Software BZ 7131 1/3 oct. Frequency Analysis Software BZ 7132 Logging Software BZ 7133 Signal
Frequency selective monitoring and logging of environmental electromagnetic fields
FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser
The next generation of noise measurement instruments
The Invictus Noise Monitor The next generation of noise measurement instruments The Invictus Noise Monitor The next generation of noise measurement instruments The Invictus is a range of next generation
Quad Core Intel Xeon Processor E3. 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.
VS-12164U-RP Pro Hardware Spec. Processor HDD Capacity Quad Core Intel Xeon Processor E3 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The system is shipped without HDD. 2. For the HDD compatibility
Wireless Day / Night Cloud Camera TV-IP751WIC (v1.0r)
(v1.0r) TRENDnet s Wireless Day / Night Cloud Camera, model, takes the work out of viewing video over the internet. Previously to view video remotely, users needed to perform many complicated and time
Amcrest 960H DVR Quick Start Guide
Amcrest 960H DVR Quick Start Guide Welcome Thank you for purchasing our Amcrest 960H DVR! This quick start guide will help you become familiar with our DVR in a very short time. Before installation and
A-307. Mobile Data Terminal. Android OS Platform Datasheet
A-307 Mobile Data Terminal Android OS Platform Datasheet Revision 1.1 July, 2013 Introduction A-307 Platform Overview Introduction A-307 Platform Overview The A-307 provides Original Equipment Manufacturers
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Recording. http://www.qnap.com/nvr/compatibilityx01.html. Smart recording (depending on the camera models)
VS-2108L Hardware Spec. CPU Marvell 1.6GHz DRAM 512MB DDRIII RAM Flash Memory 512MB Hard Disk Drive 2 x 3.5" SATA I/II hard disk drive (HDD) NOTE: 1. The system is shipped without hard disk drives. 2.
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM Revised: August 28, 2014 PRODUCT REFERENCE MOUNTING ACCESSORIES PIR / MOTION DETECTION UNIT MAIN UNIT POWER ADAPTER MOUNTING ACCESSORIES
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
ViewSync ViewSync Wireless Presentation Gateway Dongle
ViewSync ViewSync Wireless Presentation Gateway Dongle ViewSync WPG300 The ViewSonic WPG-300 is a powerful and secure wireless dongle with an HDMI-MHL (Media High-Definition Link) interface. The WPG-300
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
Specifications for the Gateway M1300 Tablet PC
Specifications for the Gateway M1300 Tablet PC Specifications are subject to change without notice or obligation. Processor and Core Logic Processor options Chipset Processor packaging Level 2 cache Core
User Manual I1010Q16DCZ
User Manual I1010Q16DCZ Explanation, Note and Warning *Explanation: important information, which can help you better use your tablet PC. *Note: indicates that not observing the content may result in hardware
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Raptor RXi Ultra-fast scanning Countersurveillance Receiver
data sheet RAPTOR RXi DATA SHEET A MATTER A MATTER OF OF NATIONAL SECURITY Raptor RXi Ultra-fast scanning Countersurveillance Receiver Features + Scans 26GHz in less than 4 seconds at 3kHz resolution (approx.
Product Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
Connect up to a total of 8 cameras from GV IP cameras (excluding GV Fisheye cameras) and third party IP cameras (of 640x 480
- 1 - Introduction Support up to 8 units of megapixel GV IP cameras Support third party IP cameras The GV NVR System Lite is a light weight and an ultraslim GV NVR System, with which you can record video
GV-FE420. Visítenos: www.dluxsecurity.com. Cámara IP Fisheye Megapixel
GV-FE420 Introduction The GV FE420 is a fisheye camera that allows you to monitor all angles of a location using just one camera. The distorted hemispherical image of the fisheye camera will be converted
Field Service Application
Field Service Terminal 3.5 TFT sunlight readable LCD touch screen Marvell PXA 310 624MHz CPU Built-in Windows Mobile 6.5 OS Wi-Fi, and WCDMA/HSDPA or GPRS wireless technology Built-in 1D Laser/2D Imager
SPL 2-00/-01 OPERATION INSTRUCTIONS
SPL 2-00/-01 OPERATION INSTRUCTIONS Powerline Ethernet Adapter 500 Mbps EN Read and keep Operation Instructions SPL 2-00/-01 Safety Notes Do NOT use this product near water, for example, in a wet basement
EDM Cloud Remote Monitoring Solutions. Crystal Instruments, January 2014
EDM Cloud Remote Monitoring Solutions Crystal Instruments, January 2014 Architecture 1: EDM Cloud runs on the Internet Spiders at multiple locations Client Browser EDM Data Server Ethernet or Wireless
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
USER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
QuickSpecs. HP ipaq rz1715 Mobile Media Companion. HP ipaq rz1715 Mobile Media Companion. Overview
Overview 1. Charge/Notification LED indicator 5. 5-Way Navigation Touch Pad 2. QVGA Color Display 6. Messaging Button 3. Calendar Button 7. Today Screen Button 4. Contacts Button 8. Stylus DA - 11970 North
www.vicon-security.com
Data/Spec Sheet 16-Channel Hybrid Digital Video Recorder Configured with ViconNet Video Management Software (VMS) Scalable from one to hundreds of recorders Support for HD video and Megapixel cameras Real-time
Table of Contents. System Requirement of MP3 Player:... 4. Connection and Downloading... 7. Downloading DRM10 Files... 8.
Table of Contents Instructions... 1 Precautions... 2 System requirements... 4 System Requirement of MP3 Player:... 4 Introduction... 5 Features... 5 Charging the Battery... 6 Connection and Downloading...
How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip
Thomson Telecom S.A.S with a capital of 130 037 460 RCS 390 546 059 Copyright THOMSON 2005 All rights reserved 09/2005-1 www.speedtouchpartner.com ST2030 TM SIP European Community Declaration of Conformity
GETTING TO KNOW YOUR NEW TELSTRA MOBILE WI-FI 4G
GETTING TO KNOW YOUR NEW TELSTRA MOBILE WI-FI 4G LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Telstra Mobile Wi-Fi 4G. This guide will help you get started as quickly and easily
INTRODUCTION. -1- GV-LX4C3 Series April 24, 2012
-1- INTRODUCTION The four channel GV Compact DVR V3 is a mobile video recorder, simultaneously displaying real time images from four cameras. The recording frame rate of each channel is adjustable up to
2-Megapixel Sony Progressive CMOS Sensor with Super Wide Dynamic Range and High Frame Rate
SD-2020 2-Megapixel 20X Optical Zoom Speed Dome IP Camera 1/2.8" Sony Progressive CMOS Sensor Full HD 1080p + D1 Real-Time at Dual Streaming Up to 20x Optical Zoom Up to 30 fps @ 1080p Full HD Weather-Proof
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
Continuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057-03/G Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total EMF values Electric field monitoring
User Manual. CEL-63x Environmental Noise Meter HB3356-02. User Manual
User Manual CEL-63x Environmental Noise Meter HB3356-02 User Manual CASELLA MEASUREMENT Regent House, Wolseley Road, Kempston, Bedford, MK42 7JY, U.K. Phone: +44 (0) 1234 844 100 Fax: +44 (0) 1234 841
Wireless PTZ Cloud Camera TV-IP851WC (v1.0r)
(v1.0r) TRENDnet s Wireless PTZ Cloud Camera, model, takes the work out of viewing video over the internet. Previously to view video remotely, users needed to perform many complicated and time consuming
22 (21.5 viewable) Smart Display, Full HD, Rockchip Quad-Core, Optical touch, Android KitKat. VSD224
22 (21.5 viewable) Smart Display, Full HD, Rockchip Quad-Core, Optical touch, Android KitKat. VSD224 The ViewSonic VSD224 is a 22 (21.5 viewable) all-in-one Smart Display with 1920x1080 Full HD resolution.
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
AC3200 INTELLIGENT BROADBAND AMPLIFIER
Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both
1.1 Overview of the ChromeLab Components
1.1 Overview of the ChromeLab Components Module 1.1: Training Objective The objective of this module is to provide detailed product training to the participant of this course. The trainee when they have
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
`````````````````SIRE USER GUIDE
`````````````````SIRE USER GUIDE Table of Contents INTRODUCTION 3 SYSTEM REQUIREMENTS 4 RUNNING SANDISK BACKUP 5 Setup Your First Backup 6 Create Your Backup 7 Custom Backup 8 Dmailer Online 10 Launch
www.64817.com www.64817.com www.64817.com Integrating Sound Level Meters LA-5570/5560/2560
www.64817.com www.64817.com www.64817.com Integrating Sound Level Meters LA-5570/5560/2560 High-functionality Integrating Sound Level Meters Type1Sound Level Meters High sensitivity Wide band LA-5570/5560
Inspiron 15. 5000 Series. Views. Specifications
Inspiron 15 5000 Series Views Copyright 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell and the Dell logo are trademarks
Enterprise WiFi System. Datasheet. Models: UAP, UAP-LR, UAP-Pro, UAP-Outdoor, UAP-Outdoor5
Enterprise WiFi System Models: UAP, UAP-LR, UAP-Pro, UAP-Outdoor, UAP-Outdoor5 Unlimited Indoor/Outdoor AP Scalability in a Unified Management System Breakthrough Capacity up to 750 Mbps Intuitive UniFi
FMT600BT Transmitter
Technaxx FMT600BT Transmitter User Manual Transfer of music and calls directly from your Bluetooth device to your car radio This device complies with the requirements of the standards referred to the Directive
Product Information S N O. Portable VIP protection CCTV & Alarm System 2
Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to
Falcon Protector Tracking System
Falcon Protector Tracking System Product Overview The Falcon Protector is a GPS and GSM tracking device which is specially developed and designed for vehicle tracking. With the latest SIFR III GPS module
iva Cable & Antenna Analyzer
iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return
Megapixel PoE Day / Night Internet Camera TV-IP572PI (v1.0r)
(v1.0r) PRODUCT OVERVIEW The Megapixel PoE Day / Night Internet Camera, model TV- IP572PI, transmits real-time Megapixel video over the Internet. Record crisp video in complete darkness for distances of
Your Phone This section introduces you to the hardware of the device.
Your Phone This section introduces you to the hardware of the device. No. Items Functions 1 Earphone jack 2 Strap hole 3 LED / Speaker Use a headset for hands-free conversation or listening to music. It
300Mbps Wireless N Ceiling Mount Access Point
Datasheet Ceiling Mount Access Point 110 Highlights Wireless N speed up to 300Mbps Controller Software enables administrators to easily manage hundreds of s Supports passive PoE for convenient installation
BLU Vivo 4.3 User Manual
BLU Vivo 4.3 User Manual 1 Table of Contents Phone Safety Information... 3 Appearance and Key Functions... 4 Installation and Charging... 5 Phone Operation... 7 Communication... 10 Camera... 11 Gallery...
AXIS 262+ Network Video Recorder
31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,
A-317. Mobile Data Terminal. Android Platform Datasheet
A-317 Mobile Data Terminal Android Platform Datasheet Revision 1.4 October, 2014 Disclaimer: Micronet reserves the right to change product specifications without prior notice. Introduction A-317 Platform
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
GV-Keyboard. User's Manual V2.0
GV-Keyboard User's Manual V2.0 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2007 GeoVision, Inc. All rights reserved.
2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The standard system is shipped without HDD. 2. For the HDD compatibility list, please
VS-2104 Pro+ Hardware Spec. Processor Memory HDD Capacity Dual-core Intel processor 4GB RAM 2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The standard system is shipped without HDD. 2. For the
PE6108/PE6208/PE8108/PE8208
Energy Intelligence Solutions PE6108/PE6208/PE8108/PE8208 eco PDU Distribution Unit ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment
AUROLEX Plug and Play Monitoring The best ways to achieve a cleaner, safer environment R AUROLEX MONITORING SYSTEEM The flexible Aurolex Monitoring System offers users the ability to simultaneously measure
Aastra DT690 and DT390 Cordless Phones» Making cordless work for you
Aastra DT690 and DT390 Cordless Phones» Making cordless work for you DT690» The clear choice for demanding users The DT690 is the clear choice for demanding office users, but is also developed for use
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.
Remote Lighting Kit Table of Contents Lighting Kit Overview 2 System Requirements 3 Basic Concepts of Wireless Routers and Networks 4 Basic Concepts of Network Light Bulbs 8 Planning Your Lighting Network
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
Datasheet. Unified Video Surveillance Management. Camera Models: UVC, UVC-Dome, UVC-Pro NVR Model: UVC-NVR. Scalable Day or Night Surveillance
Unified Video Surveillance Management Camera Models: UVC, UVC-Dome, UVC-Pro NVR Model: UVC-NVR Scalable Day or Night Surveillance Advanced Hardware with Full HD Video Powerful Features and Analytic Capabilities
ATM Video Surveillance
ATM Video Surveillance with centralized video management Secure your ATMs with robust and reliable video surveillance solution Record record H.264 compressed video using less hard disk space Search search
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
ACR880 GPRS Portable Smart Card Terminal
ACR880 GPRS Portable Smart Card Terminal Technical Specifications Subject to change without prior notice Table of Contents 1.0. Introduction... 3 2.0. Features... 4 3.0. Supported Card Types... 5 3.1.
300Mbps Wireless N Gigabit Ceilling Mount Access Point
Datasheet 300Mbps Wireless N Gigabit Ceilling Mount Access Point 120 Highlights Wireless N speed up to 300Mbps The Controller Software enables administrators to manage hundreds of s easily from any PC
LMS Test.Xpress Powering personal productivity
LMS Test.Xpress Powering personal productivity LMS Test.Xpress Powering personal productivity Traditional analyzers have proven to be one of the most flexible tools to qualify a product s noise and vibration
LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: [email protected] url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
Continuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057 Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total emf values Magnetic fields monitoring from
