grease, sediment and oil
|
|
|
- Ralph Martin
- 10 years ago
- Views:
Transcription
1 Uniclass EPIC CI/SfB (52.4) March 2014 grease, sediment and oil
2 GREASE CONVERTERS A privately owned UK company with more than fifty years experience in the industry, Wade is established as a leading manufacturer of quality drainage products. Much of the success of the Company is attributable to an ongoing commitment to put technology to practical use, to generate fresh ideas, and to guarantee quality assured production. Meeting demands of water and municipal authorities, environmentalists, employers and employees, Wade provides effective and easy to use means of dealing with grease, oil and sediment. Actimatic Grease Converter Why use a Wade Actimatic Grease Converter? Grease flushed down the drain can cause blockages and unpleasant smells in work areas. Blockages can lead to overflows and health hazards, whilst drain clearing is an inconvenient and costly operation. A Wade Actimatic Grease Converter eliminates such problems and is a Natural means of Permanently converting grease to bio-degradable products. Use of an Actimatic Grease Converter is far more acceptable than chemicals or detergents which merely move grease downstream to become a problem for someone else. 2
3 GREASE CONVERTERS Degradation is a natural, slow process. Wade Actimatic uses only natural organisms to accelerate this process. Some typical locations where Wade Grease Converters are installed. How does it work? The Actimatic Grease Converter works in two stages: 1. Separation effluent entering the converter passes over a hydrafilter baffle* which causes grease to form in globules which float to the surface. 2. Digestion achieved by Wade Actimatic which produces a colony of micro-organisms to degrade wastes and convert to water soluble, environmentally friendly products. Oil Rig, North Sea Asda Store, Runcorn A McDonalds Restaurant Stock Exchange, London *Patent No Quality assurance Certification of compliance with BS EN ISO 9001 underlines our commitment to quality and service. 3
4 GREASE CONVERTERS Types of installation Floor standing (Standard and low profile models) Fully recessed in ground floor (Standard invert models) Fully recessed in ground floor (Deep invert model) Fully recessed in intermediate floor (Hanger type) Installation guidelines Wade Actimatic Grease Converters are designed to be installed in existing or new kitchens, at restaurants, canteens, hotels, hospitals, etc., and also at commercial or industrial premises where food is cooked, prepared or processed. They are not suitable for use with dedicated chicken rotisserie ovens unless special housekeeping measures are taken, including the introduction of water. There is no optimum distance between the last fixture and the converter; it is generally accepted that pipework longer than 8 metres may allow grease to solidify before it reaches the converter. It is not recommended that waste disposal units discharge into a Grease Converter, because frequent cleaning out will be necessary. Waste from vegetable peelers must be filtered before discharging. Certain cleaning agents (Chlorine, strong caustics, bleach etc.) in concentrated form, have a detrimental effect, and should not be discharged into a Grease Converter. Installations may require prior approval from the Local Authority Environmental Health Department. Wade Actimatic Grease Converters satisfy current Building Regulations / Standards in the U.K., and meet requirements of drainage systems designed in accordance with BS EN :2000. Spigot adaptors for connecting to different types and sizes of pipework are shown on page 8. Note: Do not reduce the stated inlet or outlet size otherwise blockages could occur. 4
5 GREASE CONVERTERS Stainless steel grade 304 How to select and size Grease Converters To determine the optimum size of converter to be used, account must be taken of the volume of fixtures discharging into the converter. Use the table below to calculate total volume by entering the quantity of each fixture, multiply by the volume shown and enter as Total Vol.; finally, add up your answers. Type of fixture Approx. size Approx. vol. Total vol. (mm) (litres) Quantity (litres) Handwash sink 300 dia. x 180 deep 12 Domestic single sink 450 x 350 x Domestic double sink (450 x 350 x 200) x 2 64 Commercial sink 600 x 450 x Double commercial sink (600 x 450 x 300) x Commercial potwash sink 760 x 500 x Tilting kettle 150 Small dishwasher Outlet pipe 32 dia. 185 Medium dishwasher Outlet pipe 40 dia. 235 Large dishwasher Outlet pipe 50 dia. 350 Other fixtures Total volume of fixtures (litres) 6000 Series 6200 Series A A B G C 150 Min. E E D 2" BSP vent pipe connection (Vent to atmosphere if required) C 200 min. 140 D B F After selecting the appropriate TYPE of INSTALLATION, and calculating the TOTAL VOLUME of FIXTURES, select the Spec.Code from the table below and add the required C dimension to nearest 10mm. e.g. for Converter to serve fixtures with a total volume of 325 litres and having a C dimension of 400mm, Specify: 6060XT C = 400mm. For details of materials, accessories and alternative covers, refer to page 8. Type of Max. total vol. of Spec. In/Outlet A B C D E F G Req. slab Load installation fixtures in litres code BSP inches mm mm mm mm mm mm mm opening class Floor standing Low profile LR l l A LR l l l A LR l l l A LR l l l A15 Floor standing Standard invert l l l A l l l A l l l A15 Fully recessed XT l l l l A15 ground floor XT l l l l A15 Deep invert XT l l l l A15 Fully recessed l l D400 ground floor l l D400 Fully recessed H l l l 625 x 445 A15 intermediate floor H l l l 805 x 545 A15 Hanger type H l l l 1020 x 730 A15 For the hanger types listed, the dimension from finished floor level to the underside of the hanger frame (normally slab level) is adjustable on site from 35mm minimum to 75mm maximum. N.B. In practice fixtures do not all discharge at the full rate simultaneously. This has been allowed for and the table enables the correct grease converter to be selected. In abnormally high or dump situations contact our Technical Services Department. To be specified on order 5
6 GREASE CONVERTERS Wade Actimatic Powder and Liquid Wade Actimatic is a bacterial product specifically formulated to deal with kitchen effluent. It is available in powder or liquid form. Actimatic Powder is a free flowing, buff coloured, granular powder; Actimatic Liquid is a green coloured, watersoluble liquid which is suitable for manual and automatic dosing. For technical information refer to back cover. To function efficiently grease converters must be dosed regularly with Wade Actimatic. Daily dosing is recommended, but where this is impracticable, dosing twice weekly is an acceptable minimum. When a converter is first put into service, and whenever it is cleaned out, a culture must be established or re-established within the converter per the Initial Dosing Procedure. The best time for dosing is just before closing down for the night; this is because the micro-biological activity is more effective when there is least flow through the converter. Details of automatic dosing are given on page 7. Initial dosing procedure (1 3 days after kitchen commences operation) Actimatic Powder Day 1 (a) Mix 8 level scoops (280 gm) with 2.25 litres (4 pints) of lukewarm water (30ºC); stir to form a slurry. (b) Remove the dosing plug from the converter and pour in the slurry. (c) Wipe up any spillage and replace the dosing plug. (d) Wait at least 4 hours before allowing any discharge into the converter this waiting time enables the micro-organisms to grow and reproduce in an ideal environment. Day 2 Repeat as for Day 1. Day 3 Commence daily dosing. Actimatic Liquid Day 1 Remove the dosing plug from the converter and pour in TWICE the amount shown in the Dosage Rate Guide. Day 2-7 Repeat as for Day 1 Day 8 Commence daily dosing. Daily dosing procedure Actimatic Powder Converter POWDER LIQUID Model No. Daily Monthly Daily Monthly level scoop Kg capfuls litres 6020LR LR LR LR Note: (a) Mix the amount of powder shown in the Dosage Rate Guide with a little lukewarm water (30ºC). (b) Remove the dosing plug from the converter and pour in the solution. (c) Wipe up any spillage and replace the dosing plug. Actimatic Liquid Remove the dosing plug and pour in the amount shown in the Dosage Rate Guide. Remote dosing As an alternative to using the dosing plug facility, Actimatic may be poured into a sink which empties into the converter, and flushed with lukewarm (not hot) water. Dosage rate The amount of Actimatic needed depends on the converter model and the type and number of meals prepared. If there is a build-up of grease, increase the dosage, if there is little indication of grease, reduce the dosage. Actimatic is highly concentrated; overdosing is wasteful but not harmful. Daily dosage rate guide (with monthly equivalents) If dosing twice weekly instead of daily, use three times the rate shown. To Specify / Order: Spec. Code: AL1 Actimatic Liquid (1 ltr.) Spec. Code: AP1 Actimatic Powder (1 kg) Discount applies to standing orders. 6
7 GREASE CONVERTERS Automatic dosing system A mains powered dispenser unit is available for use with Actimatic Liquid. The unit automatically doses the Converter with diluted Actimatic Liquid once daily at a time selected by the user. GO 16:34 Control box Pump The system, once set, requires only monthly attention to replenish the liquid supply, and is suitable for use in most new and existing drainage systems. A warning light and an audible alarm indicates low level of liquid. To pipe run Outlet tube 8mm dia. Nylon Control box Storage drum Low level sensor Inlet tube 8mm dia. Nylon Storage drum Grease Converter Automatic dosing system installation notes Control box should be wall mounted. Electrical V, (Fuse rating 3 amp internally protected by 1.6 amp fuse) Hz single phase supply must be continuous and connected to control box via an isolator by a QUALIFIED ELECTRICIAN. Plumbing ensure control box and storage drum are in final operating positions. Inlet connect nylon tube to pump by pushing tube into INLET fitting. Feed other end of tube through hole in cap of storage drum until it reaches the bottom of drum (tube may be cut to length if desired). Outlet connect nylon tube to pump by pushing tube into OUTLET fitting. For connection to pipework up to 50mm dia., use quick fit adjustable pipe connector supplied. If connecting to pipework above 50mm dia., drill and tap a 1/8" BSP hole in a suitable pipe run leading to the grease converter. This hole MUST be located after the last trap in the run and in the top of the pipe if the run is horizontal. Screw and seal the supplied 1/8" BSP fitting into the tapped hole. Connect free end of tube by pushing into fitting. (Tube may be cut to length if desired). Audible alarm may be easily disabled if not required. Timer programming Dosing time must be set by following the instructions supplied. Optimum start time is 2 hours after kitchen closes. Start-up operation 1. Read Health and Safety notes printed on the 1 litre jerrycan containing Actimatic Liquid. 2. Fill storage drum with water to level indicated on drum label. 3. Add 1 litre of Actimatic Liquid. Larger grease converters require an additional amount refer to drum label. 4. Replace cap on drum and ensure that tube reaches the bottom of the drum. Construction Control box enclosure suitable for wall mounting; made of flame retardant polystyrene with removable cover, sealed to IP56. Size 180mm x 110mm x 90mm deep. Fixings stainless steel grade 304 minimum. Pump peristaltic type delivering 110 ml of liquid per minute. Storage Drum 10 ltr. capacity made of high density polythene; with screw cap and carrying handle; octagonal, 229mm across corners x 381mm high. Switches push-button, sealed to IP56. Timer programmable by user; Mains On and Low Liquid Level indicators; rechargeable back-up battery (maintains the timer programme, it will not run the pump). Tubing 8mm dia. clear nylon or equivalent. Maintenance days after start-up and every 30 days thereafter, re-fill storage drum with water and Actimatic Liquid. 2. Every 30 days check fittings and tubes for leaks. 3. Every 6 months check pump tubing for signs of wear. To Specify / Order: Spec. Code: ADU Automatic Dosing Unit Spec. Code: AL1 Actimatic Liquid (1ltr.) Options: Wall mounting bracket for storage drum made of grade 304 stainless steel with large radiussed corners to facilitate cleaning add suffix MB to Spec. Code. 7
8 GREASE CONVERTERS Accessories Covers are treadplate (anti-slip) stainless steel grade 304 Covers For alternative covers, add suffix to Spec.Code as follows: Heavy Duty (class D400) HD Recessed (min. C dimension = 170) REC For use with sheet floor covering (min. C dimension = 180) SVF B Threaded pipework adaptors to connect converter to pipework A Spec. Pipework A B code T103 BS 416 / DIN T104 BS 416 / DIN T105 BS T106 BS T1702 Plastic T1704 Plastic T303 Plastic T401 Clay T402 } (Densleve) T501 Clay T502 } (Supersleve) Maintenance Commissioning period maintenance During the first few weeks of dosing operation, regular inspection of the internal condition of the Converter should be made to gauge the performance of the dosage amount. If a thickening of the contents is noted, with a distinct caking effect across the surface, or an offensive, pungent odour is emitted, then gradually increase the suggested dosage rate to compensate. If the contents appear to remain in a minimal semi-liquid state with little or no odour, this indicates successful degradation of the grease. Grease Converter performance The Converter is working if there is: (a) Consistency similar to thick soup. (b) Little or no odour. (c) No dry deposit building up on its sides. (d) No caked deposit floating on surface. (e) No grease build-up in downstream drain line. Routine maintenance Operation Remove main cover Remove and clean Hydrafilter baffle Check contents for caking Check for sediment build-up. If build-up has occurred tank should be cleaned Remove main cover Remove and clean Hydrafilter baffle Clean out tank completely Check joints and seal Frequency Quarterly Annually Whenever tank is cleaned out the Initial Dosing procedure must be repeated. Sediment build-up can be reduced if strainers are fitted to sinks to prevent solids entering the Converter. For best performance 1. Follow the Initial and Daily Dosing Procedures. 2. Do not discharge very hot water into the Converter immediately before or immediately after dosing. 3. Do not discharge chlorine, strong caustics, concentrated disinfectants, bleach or sanitisers into the Converter. 4. Do not deliberately discharge cooking oil or grease into the Converter. 5. Remember that food scraps and solid particles will settle on the bottom of the Converter and will need to be removed periodically. Do not discharge waste disposal units into the Converter. 6. Follow maintenance procedures. 7. Contact Wade Technical Services Department if you need advice; a free call out service is provided in mainland UK for regular users of Actimatic. Dosing plug (Sealed) Hydrafilter baffle Main cover seal Inlet (Threaded BSP) Anti-slip removable main cover (Sealed) Rodding access (Sealed) Anti-siphon tube Outlet (Threaded BSP) Deep seal trap Q Units with C dim.up to 750mm Materials Seal expanded closed cell neoprene. Other parts stainless steel grade 304. For grade 316 stainless steel, add suffix M to Spec. Code; a plain cover is supplied with grade 316 versions, if anti-slip cover is required add suffix MAS (anti-slip cover is grade 304). Note: 6200 series models have covers with no dosing plug or rodding access. 8
9 Sediment Interceptors SEDIMENT INTERCEPTORS Stainless steel grade 304 Sediment Interceptors are used to help prevent blockages where solids such as food scraps, hair, plaster, sediment etc. are discharged into drain lines. How does it work? Bucket lifting handle 390 x 390 Sealed removable cover Solid material is captured in a collector a bucket or, for fine particles, a filter bag which needs to be lifted out of the interceptor for emptying at an appropriate frequency. Fastener Features l suitable for floor standing or semi-recessed installations l 2" BSP female inlet and outlet may be connected to pipework by means of proprietary connectors Material Stainless steel grade 304, satin finish Seal expanded closed cell neoprene. 2" BSP inlet 430 2" BSP outlet Sediment bucket or filter bag Options For polished finish, add suffix P to Spec. Code. Routine maintenance Operation Frequency Spec. Flow rate Solids code l/sec. collector Bucket stainless steel (1.75mm dia. hole size) Bag polyester (100 micron hole size) Note: Minimum clearance above cover of 450mm is required for removal of bucket/bag Remove main cover Remove and clean collector Drain and clean tank Check joints and seal Annually 9
10 OIL INTERCEPTORS Stainless steel grade 304 Oil Interceptors Oil Interceptors are installed in drain lines to help prevent the pollution of rivers, streams, drainage systems and water treatment plants. Units are used where spillages of oil or diesel could occur such as garages, transport workshops, diesel re-fuelling and storage areas, and where vehicles or plant are washed down or steam cleaned. Oil Interceptors are not suitable for petrol and volatile liquids. How does it work? The Wade trapped Oil Interceptor works in three stages. 1. Separation Effluent entering the Interceptor passes through a filter bucket which retains solid material; oil, being lighter than water, floats to the surface, pending draw-off. 2. Removal of oil By automatic or manual means, oil flows through an adjustable draw-off point to a sump or a similar storage container awaiting disposal. 3. Removal of solids The bucket which retains solid material needs to be lifted out of the Interceptor for emptying at an appropriate frequency. Features l suitable for floor standing or recessed installations. l vent and draw-off connections are provided on both sides of the Interceptor for ease of installation and use. l draw-off points located inside the Interceptor are adjustable by the user (see drawing and notes on page 11). l loading class: D400. l recessed covers can be made to special order. l threaded inlet and outlet are for connection to pipework by means of a spigot adaptor, shown on page 8. Materials Seal expanded closed cell neoprene. Other parts stainless steel grade 304. For grade 316 stainless steel, add suffix M to Spec. Code; a plain cover is supplied with grade 316 versions, if anti-slip cover is required add suffix MAS (anti-slip cover is grade 304). 2" BSP vent connections (Both Sides) C A x B C Anti-slip, sealed removable cover Rodding access (Sealed) Outlet (Threaded BSP) Inlet (Threaded BSP) D 160 Deep seal trap Sediment bucket 2" BSP adjustable draw off (Both sides) To Specify / Order Select the appropriate code from the table and add the required C dimension, e.g. for oil interceptor to accept a flow 3.5 l/sec. and having a C dimension of 250mm. Specify 6360, C dimension = 250mm. Spec. Flow rate Inlet / Outlet code l/sec. size BSP A B C D " To be " Specified " on order * 419 Note: *Minimum C dimension available is 150mm, larger dimensions should be specified in increments of 10mm. Larger sizes of oil interceptors are available, please contact our Technical Services Department for details
11 OIL INTERCEPTORS Installation Notes: 1. 2" BSP Vent and drawoff connections are provided on both sides of the interceptor for ease of installation. 2. All connection points not used must be sealed. 3. Ensure location of interceptor enables easy access to draw-off valve and cover. Settings of adjustable draw-off Adjustable draw-off INLET OUTLET Adjustable draw-off Interceptor vents. Ensure pipework is extended so that one vent finishes 250mm. above the other. Draw-off valve (not supplied). Required only if manual operation is desired. To receiving container. For automatic operation use storage tank. For manual operation any suitable container may be used. Normal water operating line 3mm Normal water operating line 6mm Static water line To receiving container Static water line To receiving container Setting A Ensures that only oil is taken from interceptor Normally used in automatic installations with drawn-off oil collecting in storage tank. This setting will retain a layer of oil in the interceptor. Checking operation If during normal working conditions water is found to be entering the draw-off line, the following action should be taken; For manual and automatic operations: Adjust draw-off upward by 3mm. Check operation, repeat if required. Maintenance Commissioning period maintenance Manual draw-off During the first 4 weeks of operation, regular inspection of the internal condition of the interceptor should be made to determine how often the oil needs to be drained off and the sediment bucket emptied. Automatic draw-off During the first 4 weeks of operation check the oil storage tank for build-up, and the sediment bucket to determine how often it needs to be emptied. Routine Maintenance Operation MANUAL Remove main cover Drain off oil Remove and clean sediment bucket AUTOMATIC Remove main cover Remove and clean sediment bucket BOTH TYPES Remove main cover Remove and clean sediment bucket Drain and clean tank completely Check joints and seal Frequency As indicated by inspection during commissioning period. Annually Setting B Ensures that ALL oil is removed from interceptor Normally used with manual draw-off installations. This setting will allow water to enter the draw-off line. Checking operation If during normal working conditions oil is found to be remaining in interceptor, the following action should be taken; Manual installations: Draw-off oil more frequently and/or lower draw-off by 3mm. Check operation and repeat if required. Automatic installations: Lower adjustable draw-off by 3mm. Check operation, repeat if required. Sediment bucket Vent connections Inlet Baffle plates Anti-slip main cover Rodding access Main cover seal Outlet Adjustable draw-off Trap 11
12 GREASE CONVERTERS SEDIMENT INTERCEPTORS OIL INTERCEPTORS Wade Actimatic supplementary information Wade Actimatic is a mixture of micro-organisms, free enzymes, inorganic salts, buffers and non-ionic surfactants. Six strains of micro-organism are selected because of their ability to produce the enzymes required to break down the range of waste materials produced by the catering industry. The micro-organism population comprises a range of bacilli, micrococcus and streptomycete cultures. Four main types of enzymes are produced by the micro-organisms which operate in Wade Actimatic: Lipases to break down fats and grease Amylases to break down starch Proteases to break down protein Cellulase to break down cellulose Enzymes serve to accelerate the establishment of the micro-biological culture; they have a limited life and will eventually be used up. Any dead micro-organisms will themselves be broken down and digested by other bacteria. The micro-organisms in Actimatic Powder are naturally occurring and are not genetically engineered or genetically modified; they belong to Class1 as defined in the EU Council Directive 90/679/EEC of 26th November, 1990 and as amended by EU Council Directive 93/88/EEC of 12th October, Actimatic Powder and its intermediates are tested using procedures recommended by the USDA and AOAC to ensure that they are free of Salmonella. Environmental impact. The term BOD, biological oxygen demand, is often used in association with biological breakdown. BOD is a measure of the amount of organic matter in water and waste; it is the amount of oxygen in a given volume of water, consumed by microorganisms during the degradation of organic matter over a five day period. High BOD causes concern since the loss of soluble oxygen in the water can create anaerobic conditions, which give rise to the production of foul odours arising from the formation of sulphides (particularly H 2 S ) and methane; these conditions inhibit the degradation of fats and grease. Wade Actimatic will not increase the BOD of the discharge from a correctly sized grease converter, nor the BOD loading of the final effluent plant. All the ingredients of Wade Actimatic are bio-degradable and will have no adverse effect on the downstream biological clean-up operation. Grease is converted permanently into soluble products which will not re-deposit further down the drainage system. Wade Actimatic, when properly used, is not harmful to people, wildlife or the environment. Independent product assessment: In 1989 Wade became the first manufacturer of grease converters to be awarded an Agrément Certificate. For the Grease Converter, an innovative product, there is no applicable British or European product standard. BS EN 1825 applies to products that require the physical removal of grease; the scope of the standard states The standard does not cover the use of biological means (bacteria and enzymes). Other products Wade manufactures a wide range of products for use in and near all kinds of buildings, worldwide: Floor gullies, access covers, channel and grating, roof outlets, water points. Full details, including CAD files are accessible on our website Service Product information and technical advice are available from the Wade Technical Services Department at Halstead, Essex, from Wade Technical Consultants located throughout the UK and from selected distributors throughout the world. Warranty The Company warrants its products to be free from defects in material and workmanship for a period of 12 months from the date of delivery. The Company s obligation under this warranty is limited, at its option, to the repair or replacement, free of charge, or refund of the net invoiced price of any part found to be defective, and which, in the Company s opinion, has not been subject to undue wear and tear, accident, alteration, abuse or misuse. Consequential damages are expressly disclaimed. Technical advice from Wade International Ltd., whether verbal, in writing or by way of trials, is given in good faith but without warranty. The application, use and installation of the Company s products are beyond the control of the Company and the purchaser is solely responsible for ensuring that goods are fit for any particular purpose. In line with the Company s policy of continual research and development, product specifications and availability are subject to change or withdrawal without prior notice. Dimensions In line with general practice all dimensions shown are nominal. Load rating class This catalogue shows the load rating class for covers based on BS EN 124. QUALITY BY TRADITION PERFORMANCE BY DESIGN Wade International Ltd. Third Avenue. HALSTEAD Essex. CO9 2SX. UK TELEPHONE: +44 (0) FACSIMILE: +44 (0) [email protected]. web site:
CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION
CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION Grease, So What's the Problem? Does your facility produce grease? All commercial cooking facilities generate Fats, Oil, and Grease
National Precast Concrete Association
National Precast Concrete Association NOTES 1. This manual does not claim or imply that it addresses any safety-related issues associated with its use. Operation and maintenance of precast concrete grease
31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE
31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE Edited 21/12/01 Wyong Shire Council has many non sewered areas that
Disposal of Fats, Oils, Grease and Food Waste Best Management Practice for Catering Outlets
Disposal of Fats, Oils, Grease and Food Waste Best Management Practice for Catering Outlets Working in partnership with: Blank inside front cover page Best Management Practice for Catering Outlets Fat,
Plumbing for retail food businesses
Plumbing for retail food businesses Every day, thousands of food outlets in Sydney produce waste, such as cooking oil, grease and food solids. If that waste is discharged directly into our sewers, it can
Biological Drain Maintenance Systems
Biological Drain Maintenance Systems 2007 NCH Corporation HISTORY OF DRAINS MODERN SEWAGE SYSTEM Septic tanks were introduced; effluent water was largely untreated causing pollution of streams and rivers.
Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities
Fats, Oil and Grease Best Management Practices Manual Information, Pollution Prevention, and Compliance Information For Food Service Facilities Pinellas County Utilities Water Quality Management Division
INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812
TABLE OF CONTENTS Pictorial Index Product Recommendations Grease Interceptors Commonly Specified Options Typical Installations Oil Interceptors Commonly Specified Options Typical Installations Sediment
Bio-Clean. for Septic Systems. Tips for Using Bio-Clean. Page Index METRIC CONVERSIONS
Bio-Clean for Septic Systems METRIC CONVERSIONS 1 tablespoon = 15ml 1/4 cup = 57 ml 1/3 cup = 76 ml 1/2 cup = 114 ml 1 pint = 1/2 litre 1 quart = 1 litre 1/2 gallon = 2 litres 1 gallon = 4 litres 1 pound
Grease Trap Maintenance, Procedures and Cleaning Logs
SAWS Grease Reduction Program Grease Trap Maintenance, Procedures and Cleaning Logs Don t Feed the Grease Monster Best Management Practices for Commercial Food and Restaurant Facilities Train kitchen staff
Best Management Practices Fats, Oils, & Grease
Best Management Practices Fats, Oils, & Grease for Food Service Facilities Public Works Department Environmental Division Table of Contents A. Introduction B. Purpose of the Manual 1 C. Frequently Asked
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
Septic System Care & Maintenance
Septic System Care & Maintenance A User s Guide for Home/Cottage Owners Spring 2003 Preventing Septic Failure & Malfunction How many of us know how our septic system works, or think we know? We expect
SF15K SF05KSS, SF10KSS
Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water
SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.
SEPTIC TANK SYSTEMS There are three common types of septic tank systems in Tasmania Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only. Dual purpose (or all-waste)
Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012
Plumbing Code in Commercial Kitchens NH BOA May 9, 2012 Main Topics Grease Interceptors Indirect Waste Receptors Cleaning Chemical Dispensers Thermal Expansion IPC - Chapter 10 Traps Interceptors Separators
A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS
GEORGIA DEPARTMENT OF HUMAN RESOURCES ENVIRONMENTAL HEALTH SECTION A HOMEOWNERS GUIDE TO ON-SITE SEWAGE MANAGEMENT SYSTEMS March 12, 2002 WHAT IS AN ON-SITE SEWAGE MANAGEMENT SYSTEM An on-site sewage management
40 ltr Domestic Grease Trap GTO1. 200 ltr Commercial Grease Trap GTO2. Rotational Moulders providing State of the Art Product Design and Developement.
Rotational Moulders providing State of the Art Product Design and Developement. The JFC Grease Trap system is designed: GREASE TRAPS A major problem in the drainage systems of dwelling houses, restaurants,
WWW.STOPTHECLOG.COM WHY A FATS, OILS AND GREASE PROGRAM. Employee Food Service Establishment Information Sheet INTRODUCTION
Employee Food Service Establishment Information Sheet WHY A FATS, OILS AND GREASE PROGRAM Fats, oils and grease (FOG) cause serious problems in the sewer system. FOG sticks to the walls of the pipes when
ALL YOU NEED TO KNOW...
ALL YOU NEED TO KNOW... What do you know about your septic tank system? For the purposes of this booklet, a septic tank system refers to any kind of on-site sewage management system including traditional
Understanding Septic Tank Systems
Understanding Septic Tank Systems Sewage and effluent can contain a variety of human disease-causing microorganisms and parasites. Disease can be spread to humans from this material by direct contact or
Compliance Department
Compliance Department Compliance Checklist Inspection Checklist Installation Checklist Inspector:... Establishment:... Signature:... Address:... Date:... Contact Name:... Time Inspection Started:... Phone:...
FOG PRETREATMENT INFORMATION. New London Public Utilities F.O.G. Program 120 Broad Street New London, CT 06320
FOG PRETREATMENT INFORMATION 1 New London Public Utilities F.O.G. Program 120 Broad Street New London, CT 06320 Kathryn Willis Program Coordinator Phone: 860-447-5222 Introduction This information package
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
Getting the best from your urn
444448538 Standard 444448539 Deluxe Getting the best from your urn Remove any plastic film from the urn before use. Any water in the urn is due to testing and is normal. The urn must be used on a flat
Drainage and Grease Management for the Commercial Kitchen
Drainage and Grease Management for the Commercial Kitchen ACO. The future of drainage. The ACO system chain provides drainage solutions to meet the needs of tomorrow s food service facilities. Hostile
Looking after your Septic Tank System
Looking after your Septic Tank System Name: Bought to you by Address: File this in your property file. 0800 TO FLUSH Call 0800 TO FLUSH 1 What do you know about your septic tank system? Just like your
CERTIFYING DRAINLAYER
No. 9198 REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING DRAINLAYER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2013. All rights reserved. No part of this publication may be reproduced
SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.
SEPTIC SYSTEMS Who Has A Septic System? Approximately 30 percent of Connecticut s population is served by on-site subsurface sewage disposal systems (a.k.a. septic systems). This means a large percentage
Easy as 1-2-3 instructions on how to install or replace the Cleanviro waterless urinal tablet
Easy as 1-2-3 instructions on how to install or replace the Cleanviro waterless urinal tablet 1. FOR NEW INSTALLATION, TURN OFF THE MAIN WATER SUPPLY OF THE URINAL AND DRAIN THE WATER TANK BY FLUSHING
Manual contents includes:
Fats, Oil, and Grease (FOG) Best Management Practices (BMP) For Food Service Facilities Information, Pollution Prevention, and Compliance Information (2/07/06) Fats, oil and grease (FOG) can have negative
Shower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
Help protect our special places by maintaining your septic tank
Help protect our special places by maintaining your septic tank BC3136 A septic tank guide Help protect our special places Rural Auckland is a special place, but the remoteness also means that many homes
Guidelines for Precast Concrete Grease Interceptors
Guidelines for Precast Concrete Grease Interceptors Purpose Provide an overview of the basic design principals that govern why gravity grease interceptors work Provide a forum for discussion of common
Installation Instructions
PUSH Installation Instructions A DA C O M PLIA NT shown with optional Bradley 90-75 faucet Front-Mounted Barrier Free Rectangular Bowl Stainless Steel Lav Table of Contents Pre-Installation Information...........2
1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS AND INTERCEPTORS
GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS AND INTERCEPTORS Fort Worth Water Department, Pretreatment Services Division, (817)871-8305 A. Introduction: Part I: Guidance for Grease Trap
Grease and Oil Wastes Problems andsolutions A grease trap is a device used for removing oil and grease from wastewaters. Grease traps perform this
Grease and Oil Wastes Problems andsolutions A grease trap is a device used for removing oil and grease from wastewaters. Grease traps perform this function very well, provided they are constructed and
Fats, Oils, and Grease Best Management Practices Manual
Fats, Oils, and Grease Best Management Practices Manual Information, Pollution Prevention and Compliance Information For Food and Beverage Establishments 1 Contact Information: Mendocino City Community
ALL PURPOSE CLEANER. Active Ingredients. Description. Advantages. Remarkable products from Nature's own laboratory
Remarkable products from Nature's own laboratory ALL PURPOSE CLEANER Active Ingredients Proprietary blend of biodegradable organic cleaning agents in aqueous base formulation. Description Organica's All
septic systems What is a Septic System? How does a Septic System Work?
septic systems What is a Septic System? A septic system is a private sewage treatment system. They are common in rural areas where there are no municipal sewage pipes for homes, farms, businesses or other
CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673 MT. MAJOR HWY, ALTON, NH 03810
DATE: May 31, 2013 N.H. LICENSED DESIGNER OF SUBSURFACE DISPOSAL SYSTEMS 216 Hill Road Phone & Fax: 934-6206 Franklin, NH 03235 Cell: 393-3085 CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673
Jay R. Smith Mfg. Co.
Jay R. Smith Mfg. Co. G u i d e T o I n t e r c e p t i o n Traditional G.I. Semi-Automatic Draw-off G.I. Custom Made, Special Quote, Interceptors P.O. Box 3237 Montgomery, AL 36109-0237 Tel:334-277-8520
In-Line Filters and Coalescers with Automatic Drains
Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid
REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE
No. 9195 REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2013. All rights reserved. No part of this publication may be reproduced
.5.1 MAINTENANCE AND PERIODIC INSPECTION OF DRAINAGE SYSTEMS
.5.1 MAINTENANCE AND PERIODIC INSPECTION OF DRAINAGE SYSTEMS General Drainage systems should be inspected at regular intervals (not less than once a year) and, where necessary, thoroughly cleaned out at
ACO Building Drainage
Uniclass L21725 CI/SfB (52.9) August 2013 Grease management ACO Building Drainage Product catalogue ACO Gravity Grease Separators ACO Building Drainage ACO Building Drainage Our built environment is becoming
1.2 How Does FOG Affect You?. 2 1.3 The City of Huntington Beach FOG Control Program.. 2
Contents SECTION 1.0 What is FOG?.... 2 1.2 How Does FOG Affect You?. 2 1.3 The City of Huntington Beach FOG Control Program.. 2 SECTION 2.0 HOW TO ACHIEVE COMPLIANCE WITH THE FOOD SERVICE ESTABLISMENT
London Farm Kitchen Sinks
INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE London Farm Kitchen Sinks 24" Sink model number 35120 30" Sink model number 35130 36" Sink model number 35140 Certified to comply with ANSI A112.19.3.M CAN/C.S.A
Grease 101. Why is Grease a Problem?
Grease 101 Grease is hydrophobic, meaning it floats on top of water, and adheres to other material such a sewer pipes. All too often, grease is washed into the plumbing system, usually through the kitchen
How do I clean my grease trap? Refer to Grease Trap and Interceptor Maintenance.
Fats, Oil, and Grease Best Management Practices Manual Information, Pollution Prevention, and Compliance Information for Publicly-Owned Treatment Plants Fats, oil and grease - - also called FOG in the
Grease Traps and Interceptors
Grease Traps and Interceptors Dorchester County Water and Sewer Introduction Fats, oils, and greases (FOG) can build up in sewer pipes, resulting in costly and messy overflows. It is bad for business,
Chill 4 Hole Bath Shower Mixer
Chill 4 Hole Bath Shower Mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 02 2. Safety Note
Septic Tank Use & Maintenance Tips
Yellowhead County Hamlet of Cadomin Septic Tank Use & Maintenance Tips This guide gives an overview of the responsibilities for property owners in Cadomin. For Seasonal, Permanent & Vacationing Cadomin
Sealant. 30" Model No. 35020. D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation
INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE London Kitchen Sinks 24" Sink model number 35030 30" Sink model number 35020 36" Sink model number 35040 Thank you for selecting Porcher. To ensure this product
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT
Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public
KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water
Understanding and Caring for Your Septic System
Understanding and Caring for Your Septic System Summit County Public Health 1867 W. Market Street Akron, Ohio 44313 330-926-5600 www.scphoh.org The purpose of a home's subsurface septic system is to dispose
BEST ENVIRONMENTAL MANGEMENT PRACTICES
Learn how to prevent pollution, maintain a grease interceptor, minimize waste, and protect your sewer lateral by following these. BEST ENVIRONMENTAL MANGEMENT PRACTICES For FOOD SERVICE FACILITIES This
Prevent Blockages in the Sanitary Sewer System
FATS, OILS & GREASE - BMPs The following Best Management Practices (BMPs) tables are listed below: Prevent blockages in the Sanitary Sewer System Properly Maintain Grease Traps and Interceptors to Prevent
CHEMICAL CLEANING UNIT Product number: 737189
CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2
SEPTIC SYSTEM. Taking care of your. ... what you need to know
Taking care of your SEPTIC SYSTEM... what you need to know For more information, please call: WATER & WASTE MANAGEMENT PROGRAM (909) 387-4666 Visit our web site: www.sbcounty.gov/dehs A:\Septic System
3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:
3M Water Filtration Products Installation and Instruction Manual For: CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings Installer: Please leave this manual with owner/operator. Owner/Operator:
ACO Water Management: Civils + Infrastructure
ACO Water Management: Civils + Infrastructure Uniclass JR12/JR23 L731 CI/SfB (52.7) ACO Q-Ceptor Bypass and full retention oil separators ACO Q-Ceptor Introduction to the ACO Group Throughout the world
Artisan Thermostatic basin mixer. Fitting Instructions & Contents List
Artisan Thermostatic basin mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts 1. Introduction Thank you for choosing Bristan,
Blowdown vessels Meeting the requirements of HSE PM60
Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove
BLÜCHER Drain Product catalogue for floor drains
BLÜCHER Drain Product catalogue for floor drains K E E P I N G U P T H E F L O W S T A I N L E S S S T E E L D R A I N A G E S Y S T E M S BLÜCHER INTRODUCTION The Company BLÜCHER UK Ltd was founded in
Waste Oil Handling, Spill Containment & Lighting
58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20
Homeowners and Home Buyers Guide to Wells and Private Sewage Systems
Homeowners and Home Buyers Guide to Wells and Private Sewage Systems What every homeowner should know about living with a well and a private sewage system. YOUR ENVIRONMENTAL SYSTEMS Out of sight out of
Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000
Multi-Pure Whole House Water Treatment System Installation, Operation and Maintenance Manual Multi-Pure Model TO15000 Warning Please read manual carefully before proceeding with installation. It is recommended
Septic Tank Maintenance Information
Septic Tank Maintenance Information This section has been adapted from materials developed by the Rouge RAP Advisory Council On-site Septic Subcommittee, which included representatives from Oakland, Wayne
How To Prevent Grease From Getting Into The Water System
Fats, Oil, and Grease Best Management Practices Manual Information, Pollution Prevention and Compliance Information For Food Service Facilities City of St. Petersburg Water Resources Department Environmental
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems
PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems PACKAGE SEWAGE TREATMENT SYSTEM Clearwater treatment plants are ideal for single houses and employ the well proven aerobic biological
FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST
FAST Owner s Manual FOR USE WITH (NSF Std 40 & 245) MicroFAST 0.5, 0.625, 0.75, 0.9, 1.5 (non NSF certified) MicroFAST 3.0, 4.5, 9.0 (ETV/EPA tested) RetroFAST 0.150, 0.250, 0.375 NitriFAST 0.5, 0.625,
CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS
PlumbingCode06_ch10 5/29/06 8:16 AM Page 1 CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS We have covered most of the regulations you will need to know about drains and vents. This chapter will round out
Septic System Owner s Manual
Septic System Owner s Manual Sponsored by: copyright 2013 No part of this publication may be reproduced without our consent. www.callbrownies.com Brownie s Septic and Plumbing has provided quality service
Be a part of the Team! Keep the Bay CLEAN!
Be a part of the Team! Keep the Bay CLEAN! Water Quality Protection Guidelines for Food Handling Facilities Regional Water Quality Control Plant Operated by the City of Palo Alto for the communities of
Homeowner s Manual MIGHTY MAC. For: 500 Gallon-Per-Day. 600 Gallon-Per-Day. 750 Gallon-Per-Day
Homeowner s Manual For: MIGHTY MAC 500 Gallon-Per-Day 600 Gallon-Per-Day 750 Gallon-Per-Day Table of Contents I. Introduction II. About Your MIGHTY MAC System III. Homeowner (System Owner) Responsibilities
Food Handling Facilities, Waste Reduction & Water Quality Protection Guidelines
Food Handling Facilities, Waste Reduction & Water Quality Protection Guidelines Food handling facilities such as restaurants, institutional cafeterias, grocery stores, bakeries, and delis, can contribute
PROPAK AquaBio Complete Water Restoration Systems
PROPAK AquaBio Complete Water Restoration Systems Conserving natural resources and lowering operating expenses is no longer an option, it is a necessity. Water, sewer and discharge fees are continuing
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
Fats, Oil and Grease Program Kit
Fats, Oil and Grease Program Kit Rochester, MN Water Reclamation Plant 2015 COMPLIANCE, REQUIREMENTS AND BEST MANAGEMENT PRACTICES FOR FOG CONTROL AT FOOD SERVICE ESTABLISHMENTS P a g e 0 Table of Contents
foundation designed to keep water out of the basement.
Preventing Sewer Backups To safeguard your home against flooding from sewer backups, you should understand your home's basic plumbing and the preventative techniques discussed in this brochure. Basement
Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations
SWPPP for Park Operations 2 Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations Bordered by Lake Washington & Lake Sammamish, the City of Bellevue has more than 60 miles of streams,
Properly maintaining your septic system will help reduce the. It s Your Septic System. Homeowner s Guide. Here s How to Take Care of It
Homeowner s Guide for Maintenance and Care of On-Site Sewage Systems It s Your Septic System Here s How to Take Care of It Properly maintaining your septic system will help reduce the possibility of health
St. Joseph, Missouri Water Protection Homeowners Guide to Your Sewer
St. Joseph, Missouri Water Protection Homeowners Guide to Your Sewer Out of Sight, Out of Mind: Don t wait until you have a problem to maintain your private lateral sewer line. Keeping Excess Water Out
Village of St. Louis Sewer Back-up Policy
Village of St. Louis Sewer Back-up Policy The Village of St. Louis is responsible for maintaining sewer mains and manholes, which are located in public rights-of-way (Village and Provincial maintained
Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010
Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010 A. Purpose The purpose of this policy is to explain how and why sewer or stormwater backups occur, what to do in the event a homeowner
Installation & Operating Instructions
MANEP08082011 Installation & Operating Instructions Note: Please read this manual thoroughly before installation and operation Thank you for purchasing your new EazyPod filter. We are sure you will be
CEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
ECOLOGICAL LINE of bioexpert PRODUCTS
Recommended application Product s name bioexpert BIOLOGICAL TABLES for septic tanks and sewage systems for cesspools, septic tanks and sewage systems: bioexpert BIOLOGICAL DEGREASER for sewage systems
THE SEPTIC PROFESSIONALS TARGETED BACTERIAL SOLUTIONS CONSUMER PRODUCT CATALOG
THE SEPTIC PROFESSIONALS TARGETED BACTERIAL SOLUTIONS CONSUMER PRODUCT CATALOG 2 SPECIALIZED BACTERIA THAT TARGET EACH AREA OF THE SYSTEM. Unique challenges and problems occur within every part of a system.
A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE
A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE The U.L.C. Listed C142.14-03 Cubet container provides a unique solution to storage and dispensing fluids. The Cubet s logical and integrated design allows
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: This booklet should be left with the user after installation and demonstration Thank you for choosing a quality Redring product
FREE-FLOW Biological Drain Maintenance Systems. 2012 NCH Corporation
FREE-FLOW Biological Drain Maintenance Systems 2012 NCH Corporation Common Drain Line Problems Slow Drains and Backups Expensive and Ineffective Grease Trap Pumping Fats, Oils, Grease (FOG) and food particles
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine