1 PO Box 8680 Madison, WI Arctic Max TS-388 Owner s Manual Phoenix Arctic Max Installation, Operation and Service Instructions Read and Save These Instructions The new Phoenix Arctic Max is the first portable air conditioner designed specifically for the Restoration Industry. The Phoenix Arctic Max boasts one ton (2,000 BTUs) of cooling capacity operating in 95 F and 60% conditions while drawing under 2 amps. In a single pass, this provides a 5 degree temperature drop on the 430 CFM evaporator (cooling) air stream and water removal equivalent to 00 pints per day. The Phoenix Arctic Max gives the restoration contractor vital temperature control in the affected area to optimize drying efficiency or in unaffected areas to safe-guard occupant comfort. The Phoenix Arctic Max s cooling power also makes it the ideal accessory to pre-treat air to improve the performance of desiccant or LGR dehumidifiers. When used in conjunction with the Phoenix Solution LGR performance amplifier, the Phoenix Arctic Max provides a reliable cooling air stream to maximize overall performance. The Phoenix Arctic Max features thermostatically controlled cooling to insure maintenance of desired conditions and prevent potential over-cooling. Set-up and operation is simple using the Phoenix window accessory kit, and a 5 amp outlet. The Phoenix Arctic Max also features filter efficiency options up to MERV-, an internal condensate pump with 30 foot drain hose and 20 foot power cord. The Phoenix Arctic Max promises years of service and our proven performance. The Phoenix Arctic Max Portable Air Conditioner Ton, 2,000 BTUs of Cooling* 00 Pints/Day of Water Removal*.7 Amps* Adjustable Thermostat Easy Set-up and Operation Cooling (Evaporator) Airflow 430 CFM Exhaust (Condenser) Airflow 430 CFM Multiple Ducting Options Multiple Filter Options 20 ft. Vertical Lift Condensate Pump 30 ft. Drain Hose 20 ft. Power Cord (grounded) Recessed Wheels Legendary Stainless Construction *95ºF/60% RH Phoenix Arctic Max PN Specifications subject to change without notice. Revised 4/07 sales@thermastor.com

2 Table of Contents Introduction.... Specifications Operation Transporting Electrical Requirements Condensate Removal Ducting Power Switch Pump Purge Switch Hour Meter Thermostat Operation Defrost Timer Low Pressure Control Maintenance Air Filter Storage Service Technical description Troubleshooting Blower Replacement Defrost Thermostat and Timer Condensate Pump Gravity Drain Option Relay Options and Accessories Wiring Diagram Service Parts Warranty...9 Serial No. Purchase Date / / Dealer s Name Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix Arctic Max dehumidifier. Specifications Part No Power Adjustable Thermostat Range Cooling Airflow (Evaporator) Exhaust Airflow (Condenser) Filters Duct Options Condensate Pump Drain Hose 30 Power Cord Construction Warranty Dimensions.7 amps@ 95 F/60% RH 2,000 Btu/Hr, 00 ppd 430 CFM 430 CFM Cooling (evaporator) inlet: 2 x 6 x 20 MERV- Exhaust (condenser) inlet: x 2 x 20 MERV-7 Cooling (evaporator): Inlet 0 Flex-Duct Outlet 0 Lay-Flat Exhaust (condenser) inlet: Inlet 0 Flex-Duct Outlet 4 Lay-Flat or 0 Flex-Duct 20 vertical lift 20 grounded Stainless Steel cabinet, (2) 8 recessed wheels Five years; st year 00% of Parts and Labor 2nd 5th year 00% of Parts of sealed refrigeration system. Machine Shipping Width Height Depth Weight 42 lb 68 lb It is designed to be used INDOORS ONLY. If used in a wet area, plug it into a GROUND FAULT INTERRUPTER. DO NOT use the Phoenix Arctic Max as a bench or table. It must always be used in the upright position. 2 sales@thermastor.com

3 2 Operation 2. Transporting The Phoenix Arctic Max must always be upright when transported by vehicle. It may be tipped onto its handle and back for loading and moving by hand. The Phoenix Arctic Max features a high-impact plastic skid plate which protects the unit while navigating obstacles such as curbs, stairways, and while loading into vehicles. 2.2 Electrical Requirements The Phoenix Arctic Max plugs into a common grounded outlet on a 5 Amp circuit. It draws.7 Amps at 95 F, 60% RH. If used in a wet area, a ground fault interrupter (GFI) is required. If an extension cord is required, it must have a minimum of 4 gauge conductors if 25 feet long or less and 2 gauge conductors if greater than 25 feet long. 2.3 Condensate Removal The Phoenix Arctic Max is equipped with an internal condensate pump to remove the water that is condensed during dehumidification. This allows the condensate to be pumped 20 with the attached hose. If the condensate must be pumped more than 20 feet above the unit, a second pump must be added to relay the condensate. If the pump fails and the unit must be used before it can be replaced, the condensate can be drained by gravity. The air inlets and outlets on top, rear, and the side of the unit must be at least foot from walls and other obstructions to air flow. If the humid area is very large, dehumidification can be improved by adding an outlet duct to circulate air to stagnant areas. 2.4 Ducting A detachable rectangular exhaust collar is supplied to allow 0 round lay-flat duct to be attached to the Phoenix Arctic Max cooling outlet. Lay-flat plastic ducting is available. See accessories on page 6. To attach ducting to a collar, put Cooling Air Flow & Optional Ducting Optional 0 Lay Flat Duct 430 CFM the plastic duct end through the collar center and roll the duct end outward so that it overlaps the outside of the collar. The duct and collar may then be quickly attached to the Phoenix Arctic Max by snapping the collar over the four screws at the blower outlet. 430 CFM Figure Optional 0 Flex Duct PHOENIX Arctic Max Portable Air Conditioner ONE TON COOLING PERFORMANCE Therma-Stor LLC Madison, WI Condenser Exhaust Ducted Air Stream 430 CFM Duct out of Conditioned Space 4 Lay Flat Duct or 0 Flex Duct Figure CFM 2.5 Power Switch The power switch (right of hour meter) lights up when the unit is turned on. If the unit is going to run for more than 2 hours in an area below 50 F, the defrost timer should be adjusted to improve performance. 2.6 Purge Switch Pressing and holding the purge switch (left of hour meter) will cause the condensate pump to run. This pump minimizes the water left in the condensate reservoir prior to moving or storage. Hold the switch in until the flow from the condensate hose stops. 2.7 Hour Meter The digital hour meter measures the cumulative time that the unit is turned on to tenths of an hour. It stores its total when the unit is unplugged; the previous total will be displayed when the unit is next turned on. It resets to zero after 99,999.9 hours of operation. 2.8 Thermostat Operation Adjust the cooling thermostat to the desired conditioned space temperature. The thermostat has a range of 60 to 00 F. Turning to ON will operate unit continously regardless of conditioned space temperature. 2.9 Defrost Timer DRYING TIP: Air s ability to absorb moisture from wet surroundings and the Phoenix Arctic Max ability to remove moisture from that air is greatly improved at higher temperatures. The defrost cycle is automatic and designed for optimum performance above 50 F. If the unit is used in an area that is below 50 F for more than 2 hours, adjustment of the defrost timer is recommended Flex Duct 3 sales@thermastor.com

4 To adjust the defrost timer:. Unplug the unit. 2. Remove the top panel and the front cover (6 screws). 3. The timer is fastened to the base at the front of the unit. Every third peg around the dial is pushed out from the dial center except one section with 4 pegs out in a row. The grain control (8 holes at the intake of the unit below the filter) should be open. Refer to Figures 3 and 4. Figure 3: Defrost timer for operating in temperatures above 50 F. Figure 4: Defrost timer for operating in temperatures below 50 F. 4. To improve performance below 50 F, the compressor off time must be increased to allow the frost to completely melt. To do this, push the pegs out from the dial center so that the pegs alternate with 2 toward the center, then 2 out from the center, all the way around the dial except for the section now with 6 pegs out in a row. Refer to Figure Replace the cover and top panel. 2.0 Low Pressure Control If the low side refrigerant pressure drops to 5 PSIG, the low pressure control opens and shuts off the compressor and blower. It is an automatically reset control. Its primary function is to prevent damage to the compressor if a leak develops in the refrigeration system. It may also open if the unit is A) used in a cool area (below 50 F) and the defrost timer is not adjusted or B) stored where it is below 40 F and then started. Under these conditions, the unit will restart within several minutes; it may cycle several times until the unit warms up. 3 Maintenance 3. Air Filter The Phoenix Arctic Max is equipped with 2 pleated fabric air filters that must be checked regularly. The cooling air flow filter is a MERV- high efficiency filter. The condener exhaust filter is a MERV-7. Operating the unit with a dirty filter will reduce the dehumidifier s capacity and efficiency and may cause the compressor to cycle off and on unnecessarily on the defrost control. The filter can generally be vacuumed clean several times before needing replacement. Replacement filters can be ordered from the factory or purchased locally if available. WARNING: DO NOT operate the unit without the filter or with a less effective filter as the heat exchange coils inside the unit could become clogged and require disassembly to clean. 3.2 Storage There are two issues to consider when the Phoenix Arctic Max is stored between uses and both pertain to the water trapped in the unit: damage caused by freezing or biological growth. The effect of the trapped water can be greatly reduced if precautions are taken to remove as much as possible before storage.. Use the pump purge switch to reduce the water level in the reservoir. 2. Stretch the hose flat to drain it completely. If the unit will not be exposed to freezing temperatures, an alternative to reduce biological growth is to flush the unit with a bio-fungicide that is approved for use with copper, aluminum and polyethylene. To flush:. Run the hose to a drain. 2. Remove the air filter. Remove top and front cover. Slowly pour a quart of the chemical through the evaporator coil fins and drain into the drain pan. 3. Flush coil with water. 4. Hold in the pump purge switch to reduce the water level in the reservoir. 4 Service WARNING: Servicing the Phoenix Arctic Max with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death, serious bodily injury, and/or property damage. Only qualified service people should service this unit. Do not operate unit without the front panel in place. 4. Technical Description The Phoenix Arctic Max uses a refrigeration system similar to an air conditioner s to remove heat and moisture from incoming air and to add heat to the air that is discharged. Hot, high pressure refrigerant gas is routed from the compressor to the condenser coil. The refrigerant is cooled and condensed by giving up its heat to the air that is about to be discharged from the unit. The refrigerant liquid then passes through a filter/drier and capillary tubing which 4 sales@thermastor.com

5 No dehumidification, blower runs but compressor does not.. Bad connection in compressor circuit. 2. Pump safety switch closed. 3. Defective compressor capacitor. 4. Defective compressor overload. 5. Defective compressor. 6. Defective relay. Figure 5: Refrigeration system cause the refrigerant pressure and temperature to drop. It next enters the evaporator coil where it absorbs heat from the incoming air and evaporates. The evaporator operates in a flooded condition, which means that all the evaporator tubes contain liquid refrigerant during normal operation. A flooded evaporator should maintain constant pressure and temperature across the entire coil, from inlet to outlet. The mixture of gas and liquid refrigerant enter the accumulator after leaving the evaporator coil. The accumulator prevents any liquid refrigerant from reaching the compressor. The compressor evacuates the cool refrigerant gas from the accumulator and compresses it to a high pressure and temperature to repeat the process. 4.2 Troubleshooting No dehumidification, neither blower nor compressor run and power switch does not light when ON.. Unit unplugged or no power to outlet. 2. Power switch defective. 3. Loose connection in internal wiring. No dehumidification, neither blower nor compressor run with power switch ON and lit.. Low pressure control open. 2. Power switch defective. 3. Loose connection in internal wiring. 4. Check thermostat setting. Some dehumidification, blower runs continuously but compressor only runs sporadically.. Unit is in defrost cycle. 2. Defrost thermostat defective or loose. 3. Loose connection in compressor circuit. 4. Defective compressor overload. 5. Defective compressor. 6. Defective relay. Blower does not run. Compressor runs briefly but cycles on and off.. Loose connection in blower circuit. 2. Obstruction prevents impeller rotation. 3. Defective blower. Unit removes some water but not as much as expected.. Air temperature and/or humidity have dropped. 2. Humidity meter and/or thermometer used are out of calibration. 3. Unit has entered defrost cycle. 4. Air filter dirty. 5. Defrost timer incorrectly set for conditions. 6. Defective defrost thermostat. 7. Low refrigerant charge. 8. Air leak such as loose cover. 9. Defective compressor. 0. Restrictive exhaust ducting. Unit runs but does not pump water.. Hose kinked or plugged. 2. Pump motor or float switch defective. 3. Pump check valve plugged. 4. Bad connection in pump circuit. 5. Hose disconnected internally. Unit pumps water automatically but not when purge switch is pushed.. Bad connection in purge switch circuit. 2. Defective purge switch. Evaporator coil frosted continuously, low dehumidifying capacity.. Defrost thermostat loose or defective. 2. Defrost timer incorrectly set or defective. 3. Low refrigerant charge. 4. Dirty air filter or air flow restricted. Compressor runs with power switch OFF.. Defective relay. 2. Defective power switch. 5 sales@thermastor.com

6 4.3 Blower Replacement The motorized impeller has a PSC motor and internal thermal overload protection. If defective, the complete assembly must be replaced.. Unplug the power cord. 2. Remove the top and cabinet front (6 screws). 3. Disconnect the impeller leads. 4. Remove four screws holding the impeller to the impeller brackets. 5. Remove impeller. Use care to avoid hooking wiring, tubing or electrical components. 6. Reassemble with the new impeller in the above procedure reversed. 4.4 Defrost Thermostat and Timer The defrost thermostat is attached to the refrigerant suction tube between the accumulator and compressor. If the low side refrigerant temperature drops due to excessive frost formation on the evaporator coil, the thermostat opens. The compressor is then cycled off and on by the defrost timer. The blower will continue to run, causing air to flow through the evaporator coil and melt the ice when the compressor is off. When the air temperature and/or humidity increase, the evaporator temperature will rise and the thermostat will close to end the defrost cycle. To improve performance in low temperatures refer to Section 2.9 for defrost timer adjustment. Figure 6: Defrost thermostat Figure 7: Defrost timer 5. Connect a garden hose and run it to a drain. Keep the hose as flat to the floor as possible to avoid air pockets that would hinder draining. Placing the unit on something above the floor will also improve draining. 4.7 Relay The contacts of the single pole, single throw relay complete the power circuit to the compressor. The contacts are closed when power is provided to the relay coil via the control circuit. The control circuit includes the power switch, low pressure control, defrost thermostat and timer. 4.5 Condensate Pump Condensate is automatically pumped when the water level in the pump s reservoir rises to close the float switch or if the pump purge switch is held in. To replace the condensate pump:. Remove the metal strap holding the pump by loosening the 2 screws holding it in place. 2. Disconnect the leads. 3. Installation is the reverse of above, but check that the plastic inlet and outlet hoses do not rub against copper refrigerant tubes. Figure 8: Condensate pump 4.6 Gravity Drain Option If the condensate pump fails and cannot be replaced immediately, the Phoenix Arctic Max can be used by draining by gravity.. Unplug the unit and remove the front cover. 2. Push the plastic plug on the left side out from inside the unit. 3. Locate the heavy vinyl hose that connects the drain pan to the condensate pump. Pull the end out of the pump. 4. Push that end of the vinyl hose through the hole in the left side. 5 Options and Accessories Air Filter, Pleated, 2 x 6 x 20 57% MERV Insulated Flex Duct, 0 0 x 25 Metalized Polyester Lay-Flat Duct, 0 Round x 250 Roll Lay-Flat Duct, 4 Round x 250 Roll 6 sales@thermastor.com

7 6 Wiring Diagram TO CORD LIGHT GRN 2 3 HOUR METER POWER THERMOSTAT ORG ORG RELAY 2 ORG LO PRESSURE CONTROL DEFROST TIMER (VIEWED FROM BACK OF TIMER) TIMER MOTOR 2 TIMER 3 5 VIO TEST BUTTON CONDENSATE PUMP DEFROST CONTROL COND FAN CAP BRN BLOWER MOTOR EVAP FAN CAP BRN BLU COMP CAP YEL BLU RED FLOAT C S 2 PUMP PURGE GRA YEL BLU CONNECTOR NO NC C SAFETY GRA OVERLOAD COMPRESSOR R Therma-Stor LLC PART NO. PO BOX 8680, MADISON, WI Figure 8: Wiring diagram REV. A 7 sales@thermastor.com

8 8 Service Parts 2 Item Description Qty Part No. Filter, Cooling, 2 x 6 x Cord Front Panel Retaining Nut, / Wheel, Wheel Hub Cap Retaining Ring Hub Cap Retaining Washer Coupling Body, /4 Tube Foot Defrost Timer Low Pressure Control Filter/Drier Compressor, Carlyle (P/N EAA090A) 5 9 Overload, Carlyle Compressor Capillary Tubes Defrost Thermostat Defrost Thermostat Mounting Clip Evaporator Coil Accumulator Condensate Pump Wire Duct Collar (Cooling) Top Handle Assembly Pump Purge Switch Hour Meter Power Switch Skid Plate Instruction Label Handle Screw (M0-.5 x 35) Handle Nut (M0-.5) Thermostat Filter, Exhaust, x 2 x Duct Ring Items listed below are not shown Drain Hose (.25 ID x 33 long) Front Panel Screw, /4-20 x / Condenser Coil Motorized Impeller Fan Relay, Compressor Run Capacitor, Comp. 25 μf Run Capacitor, Fan, 5 μf Wire Duct Collar to 0 Duct Adapter Specifications subject to change without notice. 8 sales@thermastor.com

9 Warrantor: Therma-Stor LLC PO Box 8680 Madison, WI Telephone: Phoenix Arctic Max Limited Warranty Who Is Covered: This warranty extends only to the original end-user of the Phoenix Arctic Max, and may not be assigned or transferred. Year One: Therma-Stor LLC warrants that, for one () year the Phoenix Arctic Max will operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, repair or replace the defective part(s), free of any charge. Years Two Through Five: Therma-Stor LLC further warrants that for a period of five (5) years, the condenser, evaporator, and compressor of the Phoenix Arctic Max will operate free of any defects in material or workmanship, or Therma-Stor LLC, at its option, will repair or replace the defective part(s), provided that all labor and transportation charges for the part(s) shall be borne by the end-user. End-User Responsibilities: Warranty service must be performed by a Servicer authorized by Therma-Stor LLC. If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he should call Therma-Stor LLC at the above number and ask for the Therma-Stor Service Department, which will then arrange for covered warranty service. Warranty service will be performed during normal working hours. The end-user must present proof of purchase (lease) upon request, by use of the warranty card or other reasonable and reliable means. The end user is responsible for normal care. This warranty does not cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, unauthorized or improper repair or installation, accident, acts of nature or any other cause beyond Therma-Stor LLC s reasonable control. Limitation and Exclusions: If any Phoenix Arctic Max part is repaired or replaced, the new part shall be warranted for only the remainder of the original warranty period applicable thereto (but all warranty periods will be extended by the period of time, if any, that the Phoenix Arctic Max is out of service while awaiting covered warranty service). UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Phoenix Arctic Max OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA- STOR LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY Phoenix Arctic Max DEHUMIDIFIER OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY. Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the exclusion or limitation of incidental or consequential damages, so one or both of these limitation may not apply to you. Legal Rights: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 9 sales@thermastor.com

Owner s Manual Phoenix R175 LGR Dehumidifier

Owner s Manual Phoenix R175 LGR Dehumidifier PO Box 8680 Madison, WI 53708 Phoenix R175 LGR Dehumidifier TS-348 Owner s Manual Phoenix R175 LGR Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix

More information

Owner s Manual Phoenix Solution. LGR Performance Amplifier

Owner s Manual Phoenix Solution. LGR Performance Amplifier Owner s Manual Phoenix Solution LGR Performance Amplifier Read And Save These Instructions Phoenix Solution LGR Performance Amplifier Manual Part Number TS-332 The Phoenix Solution is a LGR performance

More information

www.sylvane.com 1-800-934-9194 4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R200 LGR Dehumidifier

www.sylvane.com 1-800-934-9194 4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R200 LGR Dehumidifier 4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R200 LGR Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix R200 is a compact, energy efficient

More information

Owner s Manual Phoenix 200 MAX

Owner s Manual Phoenix 200 MAX 420 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix 200 MAX Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 200 MAX is one of the most effective and versatile

More information

Owner s Manual Phoenix 300

Owner s Manual Phoenix 300 PO Box 8680 Madison, WI 53708 Phoenix 300 High Capacity Dehumidifier Part number TS-218 Owner s Manual Phoenix 300 Installation, Operation and Service Instructions Read and Save These Instructions The

More information

Quest 105, Dry155, and 205 Dual

Quest 105, Dry155, and 205 Dual Quest 105, Dry155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.

More information

Owner s Manual Phoenix D385

Owner s Manual Phoenix D385 PO Box 8680 Madison, WI 53708 Phoenix D385 TS-387 Owner s Manual Phoenix D385 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix D385 provides the perfect combination

More information

HI-E Dry DRY 195. quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. HI-E Dry 195:

HI-E Dry DRY 195. quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. HI-E Dry 195: HI-E Dry DRY 195 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Dehumidification The highly efficient Ultra-Aire 100V dehumidifier utilizes refrigeration to cool the incoming air stream

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477

More information

Owner s Manual Phoenix 1200 Desiccant Dehumidifier

Owner s Manual Phoenix 1200 Desiccant Dehumidifier 4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix 1200 Desiccant Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 1200 Portable Desiccant Dehumidifier

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

LOBOY 16 AIR CONDITIONERS

LOBOY 16 AIR CONDITIONERS INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167 PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,

More information

TABLE OF CONTENTS. Table of Contents

TABLE OF CONTENTS. Table of Contents TABLE OF CONTENTS Table of Contents 1. Specifications... 2 2. Installation... 3 2.1 Location... 3 2.1A In Humid Area, No Ducting... 3 2.1B In Humid Area, Duct Inlet and/or Outlet... 3 2.1C In Remote Area,

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

Service & Parts Manual

Service & Parts Manual Service & Parts Manual Portable Air Conditioner Models P09B and P2B ( Serial Number Beginning with an "A") Models P09B-A and P2B-A Portable Air conditioner-200 Svc Parts (4-200) Service Points and Flow

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

Geyser-R Heat pump water heater Installation manual

Geyser-R Heat pump water heater Installation manual Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

T-Series Air Conditioner T62 Model

T-Series Air Conditioner T62 Model INSTRUCTION MANUAL T-Series Air Conditioner T62 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 INSTRUCTION MANUAL FOR: T15 AIR CONDITIONER McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleanthermal.com INSTRUCTION MANUAL TABLE OF CONTENTS

More information

Ceiling Mount Air Handler Manual

Ceiling Mount Air Handler Manual www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN

More information

Troubleshooting Your Refrigerator

Troubleshooting Your Refrigerator Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation

More information

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro

More information

INSTANT HOT WATER RECIRCULATING SYSTEM

INSTANT HOT WATER RECIRCULATING SYSTEM INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 T-SERIES Air Conditioners T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 88043249 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND

More information

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Table Z. Troubleshooting Chart for Air Conditioners. Cause Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into

More information

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL Cool COMMERCIAL PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL User Manual, Guide de l'utilisateur, Manual del Usario CPN08XC9, CPN0XC9, CPR0XC9-L, CPN0XH9, CPNXC9, CPNXC9-E

More information

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use. OFF COOL 0 3 2 1 OFF Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use ON SPEED ON SWING OWNER S MANUAL Read and save these instructions before use Model: CO60PM Power rating: 220 Watts

More information

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat Owner s Manual Portable Air Conditioner with Heat ACW200C / ACW200CH It is important that you read these instructions before using your new purchase and we strongly recommend that you keep them in a safe

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...

More information

OWNER S GUIDE OPERATION & INSTALLATION

OWNER S GUIDE OPERATION & INSTALLATION OWNER S GUIDE OPERATION & INSTALLATION CARRIER RECREATIONAL VEHICLE AIR CONDITIONER PRODUCT INFORMATION Model Number Date in Service Unit Serial Number Ceiling Assembly Serial Number INSTALLER Date of

More information

Important Safeguards

Important Safeguards Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This

More information

AROS SMART WINDOW AIR CONDITIONER

AROS SMART WINDOW AIR CONDITIONER AROS SMART WINDOW AIR CONDITIONER Part of the Quirky + GE collection of smart products, Aros is an app-enabled air conditioning unit that reacts to its surroundings to save you Time, Energy & Money. TABLE

More information

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2 Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

WINDOW ROOM AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please

More information

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS FOR AC135, AC150, AC135HP, AC150HP, ACRG12, ACTH12 RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE:

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007 Service Guide Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines ORDER No: UN-SVG001A-EN DATE: October 9, 2007 Introduction This document defines American Standard and Trane s recommendations

More information

T-SERIES Air Conditioner. T53 Model INSTRUCTION MANUAL. Rev. F 2013 Pentair Equipment Protection P/N 10-1008-224

T-SERIES Air Conditioner. T53 Model INSTRUCTION MANUAL. Rev. F 2013 Pentair Equipment Protection P/N 10-1008-224 T-SERIES Air Conditioner T53 Model INSTRUCTION MANUAL Rev. F 2013 Pentair Equipment Protection P/N 10-1008-224 88004712 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR

More information

Single Zone LCD Thermostat Operating Instructions

Single Zone LCD Thermostat Operating Instructions Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip

More information

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2 Warranty Registration: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty Owner s Manual SRCOOLK (0V, 60 Hz) SRXCOOLK (30V, 50 Hz) Portable Air Conditioning

More information

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL. Rev. F 2016 Pentair Equipment Protection P/N 89104464

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL. Rev. F 2016 Pentair Equipment Protection P/N 89104464 T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. F 2016 Pentair Equipment Protection P/N 89104464 89104464 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402 TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE

More information

FOXAIR 60/50 ALL MODELS

FOXAIR 60/50 ALL MODELS FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL. Rev. S 2014 Pentair Equipment Protection P/N 10-1008-196

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL. Rev. S 2014 Pentair Equipment Protection P/N 10-1008-196 T-SERIES Air Conditioner T20 Model INSTRUCTION MANUAL Rev. S 2014 Pentair Equipment Protection P/N 10-1008-196 87976494 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR

More information

Air Conditioning Systems Warranty Manual. Version 1.8

Air Conditioning Systems Warranty Manual. Version 1.8 Air Conditioning Systems Warranty Manual Version 1.8 1/2015 Air Conditioning System Warranty Contents Purpose 4 External Distribution... 4 Policies 5 Warranty Policy Overview... 5 Warranty Period... 5

More information

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE Protected by one or more of the following U.S. Patents (3,507,354; 3,575,234; 3,596,936; 3,605,797; 3,685,329; 4,045,977; 4,698,982; 926,673 and

More information

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Installation Guide 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Table of Contents Warnings & Important Safety Instructions 3 Dimensions (Professional) 5 Dimensions (Custom Panel) 6 Specifications

More information

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS CONTENTS Parts List... 2 Parts Diagram... 2 Helpful Hints... 3 Installation... 4 Operation and Troubleshooting Guide... 6 Warranty Information... 8 Form #3132,

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

Instructional & Operating Manual

Instructional & Operating Manual Instructional & Operating Manual For CoolFreeze Series Portable Refrigerators/Freezers CF-18, CF-25, CF-35, CF-40, CF-50, CF-80, CF-110 WAECO USA Clinton, CT www.waecousa.com ! Safety indications in the

More information

Heat Pump Water Heater IOM Manual

Heat Pump Water Heater IOM Manual Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump

More information

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H HR SERIES HEAT RECOVERY VENTILATOR (HRV) Home Owners Guide Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR100V HR160H & HR220H READ AND SAVE THIS GUIDE PP0924 09/2013 ABOUT S&P S&P is the world's

More information

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner OWNERS MANUAL PAC 210 U Portable Windowless Air-Conditioner 1 IMPORTANT INFORMATION When using electrical appliances, basic safety precautions should always be followed, including the following: - Read

More information

AIR CONDITIONING UNITS

AIR CONDITIONING UNITS A/C Systems Warranty Manual AIR CONDITIONING UNITS Revision 10/2014 Doc. P/N: 10000033E AP 10000033E 10/2014 Contents: I. Spheros North America Warranty Statement II. Warranty Manual 1-7 Purpose of this

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Panel Mounted Air Conditioners by Dantherm, Inc.

Panel Mounted Air Conditioners by Dantherm, Inc. Panel Mounted Air Conditioners by Dantherm, Inc. CS020020A/B with USACG-6 Control PRODUCT INFORMATION MANUAL AC-2 CS020020 USACG-6 Manual Rev H Page 1 of 17 Dantherm, Inc. 110 Corporate Drive, Suite K

More information

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility

More information

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions

More information

Get Me Cool Now Portable Air Conditioner User s Manual

Get Me Cool Now Portable Air Conditioner User s Manual Get Me Cool Now Portable Air Conditioner User s Manual GMCN100 SERIES Questions or Concerns? Contact technical support department at 1.877.645.0299, 8 a.m. - 5 p.m., EST, Monday - Friday or www.americancomfort.com

More information

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury. 1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is

More information

Meaco 30L and Meaco 40L dehumidifier instruction manual

Meaco 30L and Meaco 40L dehumidifier instruction manual Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t. www.ice-air.com

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t. www.ice-air.com 80 Hartford Avenue Mount Vernon New York 10553 Tel: 914-668-4700 EXT. 203 Fax: 914-668-5643 www.ice-air.com Wo r l d C l a s s C o m f o r t Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE

More information

NSN 4120-01-21 4-3692

NSN 4120-01-21 4-3692 *TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21

More information

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater Portable Air Conditioner / Heater Your Guarantee Instruction Manual For model WA-1220M WA-1220H, WA-1220E P O R T A B L E Air Conditioner If this product is found to be faulty as a result of faulty materials

More information

Super Cascade Filtration Systems (CE)

Super Cascade Filtration Systems (CE) CE ONLY Super Cascade Filtration Systems (CE) Operation Manual Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. 24-Hour Service Hotline

More information

HVAC-02, Air Conditioning Troubleshooting and Repair

HVAC-02, Air Conditioning Troubleshooting and Repair HVAC-02, Air Conditioning Troubleshooting and Introduction Since I'm constantly receiving questions on 944 air conditioning systems, I figured it's time to come up with come helpful troubleshooting tips.

More information

How To Install An Evaporator Coil

How To Install An Evaporator Coil EVAPORATOR COIL INSTALLATION INSTRUCTIONS EVAPORATOR COIL SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... System Requirements... Location Requirements... Drain Requirements... INSTALLATION INSTRUCTIONS...

More information

ALL IN ONE. Heat Pump Water Heater

ALL IN ONE. Heat Pump Water Heater ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part # 11150263

Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part # 11150263 Geocontrol PRO INSTALLATION AND OPERATION MANUAL Rev. 1 03/18/04 Part # 11150263 TABLE OF CONTENTS Chapter 1: System Description... p. 05 Function and Theory...p. 05 Chapter 2: System Installation... p.

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information