Size: px
Start display at page:

Download "Protection and Control of Solid Fuel Boilers"

Transcription

1 Protection and Control of Solid Fuel Boilers Catalogue Energy-saving solutions

2 BOILER OVERHEATING PROTECTION Solid fuel boilers may get overheated during operation, mostly due to a power failure. The boiler circulation pump stops while there is glowing fuel inside and the heating water temperature starts rising quickly as the heat is not being removed. This danger can be prevented in two ways: either by recooling the boiler via a thermostatic valve that needs no energy for its operation, or by a backup source that supplies energy for the circulation pump. BOILER PROTECTION AGAINST CLOGGING AND HEAT TRANSFER SURFACE CORROSION Burning causes releasing of water, among others, from the fuel in the form of steam. If the flue gas is hot enough, the steam leaves through the chimney together with flue gas. However, if the flue gas gets cooler at some spot, condensation of water vapor occurs there. The condensate contains products of burning that can be very aggressive esp. when burning wood or solid fuel and thus cause fast corrosion and deposit formation on heat transfer surfaces (tarring). TSV thermostatic mixing valves mix cool return water from a heating system or accumulation tank with hot water from the boiler outlet. This way the whole heat exchanger (heat transfer surfaces) is kept warmer, at temperatures that will not allow condensation to occur and so fouling and quick corrosion will be prevented. Fouled heat transfer surfaces deteriorate boiler efficiency substantially and increase the risk of scale formation. Quick corrosion and fouling will not occur if the heat transfer surfaces are warm enough as condensation will not occur above certain temperatures. The heat transfer surfaces will be warmer, making their service life longer and the boiler efficiency higher. These valves are fitted with thermostatic valves made by a renowned French manufacturer. PUMP STATIONS WITH THERMOSTATIC VALVES Pump stations with thermostatic mixing valves serve for the same purpose of boiler protection as TSV valves, making installation easier as they are fitted also with circulation pumps for the boiler/heating circuit and other components. Regulus CS TSV Pump station involves also components needed for proper operation of both heating and DHW. Installation time and price is reduced this way. They are designed for installation directly on the boiler outlet pipe or on a wall. BOILER OUTPUT CONTROL Thermostatic draft regulators keep the outgoing temperature from a solid fuel boiler at the value selected by the regulator knob. They operate combustion air dampers by chains, controlling this way the boiler output. Their advantage is a robust build, mechanically sturdy and thermally resistant. Their double scale enables horizontal as well as vertical installation. High quality thermostatic elements made by a renowned French manufacturer offer precise operation and a long service life. Electric operated regulators work in the same manner, moreover they can reduce outgoing temperature from a boiler on electric signal. This way the boiler temperature and output can be controlled by a room thermostat or other electronic controller.

3 CONTENTS BOILER OVERHEATING PROTECTION DBV1 Thermostatic Valve... 2 JBV1 Thermostatic Valve... 3 BVTS Valve with Capillary... 4 PG 500 Backup Source for Solid Fuel Boilers... 5 BOILER PROTECTION AGAINST CLOGGING AND HEAT TRANSFER SURFACE CORROSION TSV3 and TSV3B - DN 25 Thermostatic Mixing Valves... 7 TSV5 - DN 32 Thermostatic Mixing Valve... 8 TSV6 - DN 40 Thermostatic Mixing Valve... 9 TSV8 - DN 50 Thermostatic Mixing Valve TSV2 - DN 50 Thermostatic Mixing Valve PUMP STATIONS WITH THERMOSTATIC VALVES Regulus Thermovar LK 810 Thermostatic Pump Station Regulus CS TSV Pump Station Regulus CS TSV MIX Pump Station BOILER OUTPUT CONTROL RT3E Thermostatic Draft Regulator, electric operated RT3 Thermostatic Draft Regulator

4 52 35,5 61,5 G ¾" 199 G ¾" BOILER OVERHEATING PROTECTION For boilers with no recooling heat exchanger DBV1 Thermostatic Valve This temperature-controlled two-way valve, working without any electricity, opens and lets cold water from the mains in at 97 C, cooling down the boiler and preventing its overheating. Hot water is discharged into a sewer. In order to work properly, the valve shall be installed to a place where the highest temperature is reached in case of overheating - usually directly in a top section of the boiler or on an outlet pipe close to the boiler. The valves are fitted with a thermostatic element from a renowned French manufacturer. Since the thermostatic element is located directly in heating water, its reaction to water temperature fluctuations is immediate. The valve has no capillary that could be damaged during installation. Functional tests are performed on each valve in production.» a reliable thermostatic element made by a renowned French manufacturer» a quick reaction to temperature fluctuations, the sensor and hot water outlet in one place» a knob for manual opening like in safety valves» no capillary - easy installation, no risk of damage 56» 100 % function controlled in production The valve is patented in many European countries. Examples of patents issued: COLD WATER IN A COLD WATER TO THE BOILER B HOT WATER TO SEWER C G ¾" 28 DBV1 Specification SENSOR AND HOT WATER FROM THE BOILER SENSOR AND HOT WATER FROM THE BOILER Opening temperature (limit) 97 C ±2 C Max. temperature 120 C Max. pressure on boiler side 4 bar Max. pressure on water side 6 bar Kvs 1.80 m 3 /h at heating water temp. of 110 C Connection to a heat source ¾ M Connection to cooling water pipe ¾ M Connection to sewer ¾ M Code 8066 COLD WATER IN TO HEATING SYSTEM KEY: shut-off valve pressure reducing valve strainer check valve (in pipe) BOILER TO SEWER safety valve FROM HEATING SYSTEM pump 2

5 G ¾" For boilers with a recooling heat exchanger JBV1 Thermostatic Valve This temperature-controlled two-way valve, working without any electricity, opens and lets cold water from the mains in at 97 C, cooling down the boiler via a recooling heat exchanger and preventing its overheating. Hot water is discharged into a sewer. In order to work properly, the valve shall be installed to a place where the highest temperature is reached in case of overheating - usually directly in a top section of the boiler or on an outlet pipe close to the boiler. The valves are fitted with a thermostatic element from a renowned French manufacturer. Since the thermostatic element is located directly in heating water, its reaction to water temperature fluctuations is immediate. The valve has no capillary that could be damaged during installation. Functional tests are performed on each valve in production.» a reliable thermostatic element made by a renowned French manufacturer» a quick reaction to temperature fluctuations» a knob for manual opening like in safety valves» no capillary - easy installation, no risk of damage 56» 100 % function controlled in production The valve is patented in many European countries. Examples of patents issued: COLD WATER IN A COLD WATER OUT B G ½" JBV1 Specification Opening temperature (limit) 97 C ±2 C Max. temperature 120 C Max. pressure on boiler side 4 bar Max. pressure on water side 6 bar Kvs 1,80 m 3 /h at heating water temp. of 110 C Connection to a heat source ½ M Connection to cooling water pipe ¾ M Code 8877 COLD WATER IN TO HEATING SYSTEM KEY: shut-off valve pressure reducing valve strainer check valve (in pipe) BOILER safety valve TO SEWER FROM HEATING SYSTEM pump 3

6 31 G ¾" G ¾" BVTS Valve with Capillary This single-way capillary valve, working without any electricity, opens and lets cold water from the mains in at 97 C, cooling down the boiler via a recooling heat exchanger and preventing its overheating. Hot water is discharged into a sewer. Model with opening temperature 108 C is usually used for fire protection of pellets or coal. In order to work properly, the capillary shall be located in a place where the highest temperature is reached in case of overheating - usually directly in a top section of the boiler or on an outlet pipe close to the boiler. The valve installs on a cooling water pipe and is currently supplied with a 1.3m or 4m capillary.» a push button for manual opening like in safety valves» the valve is not installed directly on a boiler or outlet piping Length: 1,3 m Length: 4,0 m Length: 1,3 m Ø 8 G ½" Ø24 Ø 19,5 Ø16 Ø30,5 60 Specification Opening temperature (limit) 97 C ±2 C 95 C ±2 C 108 C ±2 C Max. temperature 122 C 122 C 133 C Max. pressure on boiler side 4 bar Max. pressure on water side 10 bar Kvs 2.40 m 3 /h Sensor connection to a heat source ½ M Connection to cooling water pipe 2 ¾ F Capillary length 1.3 m 4 m 1.3 m Code COLD WATER IN KEY: shut-off valve COLD WATER IN TO SEWER TO HEATING SYSTEM strainer check valve (in pipe) BOILER safety valve FROM HEATING SYSTEM pump 4

7 80 Backup Sources PG 500 Backup Source for Solid Fuel Boilers PG 500 Backup Source for solid fuel boilers is intended to power-supply a boiler circulation pump in case of a power breakdown. This way boiler recooling is ensured and overheating avoided. PG 500 is supplied together with a special battery, 44 Ah. Unlike a current automotive battery, this one is designed for a smaller current to be drawn for a longer time. This kit will keep running* a Wilo 25/4 circulation pump for at least 5 hours. * speed 3, pump power input of 68W» the course of outlet voltage is optimized for use in circulation pump backup» indication of backup source momentary state, acoustic alarm» wide range of power supply voltage» vertical and horizontal operation possible» installation and commissioning can be done by the user» intelligent charging in two steps, protecting the battery screw terminals to connect the battery PG 500 Capacity 44 Ah Code V socket for a power cord, integrated fuse 230V socket (for a pump) 5

8 BOILER PROTECTION AGAINST CLOGGING AND HEAT TRANSFER SURFACE CORROSION Thermostatic mixing valves TSV Thermostatic mixing valves keep boiler return water temperature at a preset temperature, preventing lowtemperature corrosion and boiler clogging. The boiler then works with a higher efficiency and its service life is extended. The valve contains a thermostatic element made by a renowned French manufacturer that facilitates mixing hot outlet water with return water from a heating system or accumulation tank. In new valve models a thermostatic element with rubber gasket is used that guarantees high tightness of the valve, preventing microcirculation in periods when the boiler is extinguished. Microcirculation via a boiler is the reason of an accumulation tank getting cooled down due to heat loss via the chimney. All valves feature robust design with large cross sections for heating water flow. They are not inclined to getting clogged when installed into already operated heating systems. Sludge can be easily drained from valves of the TSV3-8 line as well as the thermostatic element cleaned or replaced by unscrewing the plug, no need to remove the valve from a heating system. TSV2 valve can be easily taken out from a heating systems due to the fitting kit supplied. During installation, it is necessary to adjust properly the balancing valve mounted in the by-pass pipe bringing hot water from the boiler outlet into the valve. TSV3B and TSV5B models do not need a balancing valve, automatic balancing of hot water incoming via a bypass is incorporated inside the valve. Its installation is so easier and control more precise. Especially in a situation when the return water temperature from a heating system or accumulation tank is close to the valve nominal temperature or higher, the valve restricts hot water flow from the bypass to complete tight closing. Due to this, the outgoing temperature from a boiler does not rise too much and so the boiler can work at full power even under these conditions. Model TSV3 TSV3B TSV5 TSV5B TSV6 TSV8 TSV2 TSV2 TSV2 Nominal diameter DN [-] Max. working pressure [bar] Connection fittings supplied YES YES YES Connection size [ ] 1 F 1 F 5/4 F 5/4 F 6/4 F 2 F 5/4 F 6/4 F 2 F Flow coefficient Kvs [m 3 /h] Automatic bypass balancing - YES - YES Weight [kg] Specific codes TSV3 TSV3B TSV5 TSV5B TSV6 TSV8 TSV2 TSV2 TSV2 45 C - high tightness * 11806* * * C - high tightness * 11807* 11820* 11818* C - standard tightness C - high tightness * 11808* 11821* 11819* C - standard tightness * * available from 9/ not available in this version HEATING SYSTEM BOILER BALANCING VALVE ACCUMULATION TANK THERMOSTATIC VALVE TSV 6

9 G1" G1" B TSV3 Valve This is the mostly used valve, suitable for boiler of output up to 35 kw or more. For boiler output up to 35 kw a pump of 4m head is sufficient (e.g. Wilo RS 25/4) and valve temperature of 65 C. For boilers of higher output valves are used with lower temperature and stronger circulation pumps. Higher valve temperature brings better resistance to corrosion and tarring. The right adjustment of a balancing valve is essential for a proper operation of TSV valves. TSV3B Valve This valve is equipped with automatic balancing of bypass flow, so no manual balancing valve is needed. The control is more precise and that is why this valve is currently used for boilers of 40 kw output and more. Valves with temperatures of 45 C, 55 C and 65 C are fitted with thermostatic elements with rubber gasket that prevent microcirculation and heat loss via a chimney in periods when the boiler is extinguished. G1" AB A 94 TSV3 Nominal temperature (outlet AB ) [ C] 45 C 55 C 65 C 77 C Flow coefficient Kvs [m 3 /h] 10.2 Max. working pressure [bar] 6 Nominal diameter DN [mm] 25 Weight [kg] 0.75 Connection size [ ] 1 F Code TSV3B Nominal temperature (outlet AB ) [ C] 45 C 55 C 65 C Flow coefficient Kvs [m 3 /h] 8.2 Max. working pressure [bar] 6 Nominal diameter DN [mm] 25 Weight [kg] 0.75 Connection size [ ] 1 F Code

10 G5/4" G5/4" 60 B TSV5 and TSV5B Valves These are new models in TSV line of valves, relating to TSV3 valve. Their connection size is 5/4 and flow rate Kvs is higher. They will be available from September 2012 in the basic version and in the version with automatic bypass balancing. For temperature of 45 C, 55 C and 65 C new thermostatic elements with rubber gasket are used that prevent microcirculation and heat loss via the chimney in periods when the boiler is extinguished. G5/4" AB A 94 TSV5* Nominal temperature (outlet AB ) [ C] 45 C 55 C 65 C 77 C Flow coefficient Kvs [m 3 /h] 12.6 Max. working pressure [bar] 6 Nominal diameter DN [mm] 32 Weight [kg] 0.85 Connection size [ ] 5/4 F Code 11802* 11803* 11804* 11836* * available from 09/2012 TSV5 B* Nominal temperature (outlet AB ) [ C] 45 C 55 C 65 C Flow coefficient Kvs [m 3 /h] 8.7 Max. working pressure [bar] 6 Nominal diameter DN [mm] 32 Weight [kg] 0.85 Connection size [ ] 5/4 F Code 11806* 11807* 11808* * available from 09/2012 8

11 G 6/4" G6/4" B TSV6 Valve TSV6 Valve has 6/4 connections and due to its high Kvs value (22 m 3 /h) it is used for boilers of 100 kw output or even more. Nowadays it is available with a 61 C thermostatic element, from September 2012 the offer will include also temperatures of 45 C, 55 C and 65 C with rubber gasket that prevents microcirculation and heat loss via the chimney in periods when the boiler is extinguished. G6/4" AB A 140 TSV6 Nominal temperature (outlet AB ) [ C] 55 C 61 C 65 C Flow coefficient Kvs [m 3 /h] 22.2 Max. working pressure [bar] 6 Nominal diameter DN [mm] 40 Weight [kg] 1.6 Connection size [ ] 6/4 F Code 11820* * * available from 09/2012 9

12 G2" G2" B TSV8 Valve TSV8 Valve has 2 connections and is the biggest model of TSV line. It will be available from September 2012 with 45 C, 55 C and 65 C thermostatic elements with rubber gasket that prevents microcirculation and heat loss via the chimney in periods when the boiler is extinguished. G2" AB A 152 TSV8* Nominal temperature (outlet AB ) [ C] 55 C 65 C Flow coefficient Kvs [m 3 /h] 31.5 Max. working pressure [bar] 6 Nominal diameter DN [mm] 50 Weight [kg] 1.75 Connection size [ ] 2 F Code 11818* 11819* * available from 09/

13 G6/4" G6/4" G2" G2" G5/4" G5/4" G2" G2" TSV2 Valve The valve has 2 M connections but it is always supplied with fittings that change the connection to 5/4 F, 6/4 F, 2 F. The connection fittings enable easy valve removal from a heating system for cleaning or thermostatic element replacement. It comes with a 61 C thermostatic element, standard tightness. Due to its high Kvs value of 20.4 m 3 /h it is used for boilers of output up to 100 kw. Thermostatic valve, 61 C, DN 50-2" G2" Thermostatic valve, 61 C, DN50 2" + 5/4" fittings G5/4" Thermostatic valve, 61 C, DN50 2" + 6/4" fittings G6/4" Thermostatic valve, 61 C, DN50 2" + 2" fittings G2" TSV2 Nominal temperature (outlet AB ) [ C] 61 C Flow coefficient Kvs [m 3 /h] 20.4 Max. working pressure [bar] 6 Nominal diameter DN [mm] 50 Weight [kg] 1.96 Connection size 3 F [ ] 5/4 6/4 2 Code

14 G5/4" G5/4" B PUMP STATIONS WITH THERMOSTATIC VALVES Regulus Thermovar LK 810 Thermostatic Pump Station In Thermovar LK 810 pump station, return water from a heating system (or accumulation tank) is mixed with boiler flow water which ensures the preset minimum temperature of the return water be maintained (55 C, 65 C, 70 C - model dependant). The pump station involves an extra floating check valve that enables boiler cooling through gravity circulation in case of a power failure, and at the same time, it prevents accumulation tank cooling down via an extinguished boiler. Thermovar LK 810 involves:» Grundfos UPSO 65 Low Energy circulation pump» Thermostatic mixing valve» Automatic balancing valve for bypass» Floating check valve» 3 thermometers» 3 ball valves with cap nuts, 5/4» Neat insulation for minimum heat loss Specification Voltage 230V 50 Hz Max. working temperature 110 C Max. working pressure 10 bar Circulation pump Grundfos UPSO 65 Low Energy G5/4" Max. flow rate set on the switch l/h l/h l/h Connection 5/4 F AB A Body material brass Dimensions Weight mm 4.8 kg LK 810 Model LK LK LK Min. water temperature entering boiler 55 C 65 C 70 C Max. boiler output 90 kw 60 kw 45 kw Code HEATING SYSTEM ACCUMULATION TANK BOILER 12

15 Regulus CS TSV Pump Station Regulus CS TSV pump station is designed for use with solid fuel boilers with no accumulation tank, DHW possible. Water entering the heating system is mixed automatically to the temperature corresponding to the boiler performance. It can work at low boiler output e.g. with temperatures of 75/65 C at the boiler, 50/40 C in the heating system. Heat output is controlled directly at the boiler, e.g. with RT3 thermostatic regulator or with a room thermostat with RT3-E regulator. CS TSV involves:» Circulation pump» Boiler pump» TSV3 thermostatic mixing valve» 2 ball valves for connection to heating system HW STORAGE WATER HEATER CW CS TSV BOILER 1 2 Safety assembly for heating systems, code The assembly contains a pressure gauge, air release valve and a safety valve. In case these components are already fitted on the boiler, this assembly is not needed. A storage water heater can be connected to the pump station. CS TSV Code Pump station with TSV

16 Regulus CS TSV MIX Pump Station CS TSV MIX Pump Station is intended for solid fuel boilers with an accumulation tank, DHW possible. Water for heating system (i.e. heat output for heating system) is mixed in a 3-way mixing valve, either with manual or electronic control. Boiler heat surplus is stored into an accumulation tank and used later automatically when the boiler goes out. CS TSV MIX involves:» Circulation pump» Boiler pump» TSV3 thermostatic mixing valve» 2 ball valves for connection to heating system» 3-way mixing valve for heating system» Mixing valve actuator (only versions with actuator, code 8118 and 11606) HW STORAGE WATER HEATER CW ACCUMULATION TANK CS TSV MIX BOILER 1 2 Safety assembly for heating systems, code The assembly contains a pressure gauge, air release valve and a safety valve. In case these components are already fitted on the boiler, this assembly is not needed. A storage water heater can be connected to the pump station. CS TSV MIX Code no mixing valve el. actuator, 65 C 7700 with el. actuator for 3-way valve, 65 C 8118 no mixing valve el. actuator, 55 C with el. actuator for 3-way valve, 55 C

17 73, BOILER OUTPUT CONTROL RT3E Thermostatic Draft Regulator, electric controlled Electric operated regulator works in the same manner as RT3, moreover it can reduce outgoing temperature from a boiler on electric signal. This way the boiler temperature and output can be controlled by a room thermostat or other electronic controller. It is fitted with a 3m silicone cable. When 12V voltage is applied, the regulator reduces temperature of heating water from the boiler. If no voltage is applied, the preset temperature is maintained. The regulator can also be controlled continuously, with 0-12V voltage. The regulator is supplied separately or in set with 12V power source and either mechanical (TP546) or electronic programmable (TP07) room thermostat. room thermostat 12V power supply RT3E G ¾" RT3E Regulator is patented. RT3E RT3E - TP546 RT3E - TP07 RT3E Ø 24,1 178 Code RT3E RT3E+TP07 RT3E+TP

18 RT3 Thermostatic Draft Regulator Draft regulator keeps the outgoing water temperature from a boiler at the value selected by the knob by controlling combustion air damper. This way the boiler output is increased or reduced. The damper is operated by a lever and chain. The controller features elegant appearance thanks to its chrome-plated body and long lifetime. Its heart is a highquality and precise thermostatic element made by a renowned French manufacturer. Its sturdy metal body offers high mechanical resistance and the materials used guarantee high temperature resistance. Its body height facilitates installation on boilers with thicker insulation. A version for boilers with extremely high insulation and mantle is also available. The standard connection size is ¾, on request 1 (not for RT3T). For 10 years we supply our RT draft regulators to dozens of manufacturers worldwide. Our customers satisfaction is proved by the fact that we manufactured over RT draft regulators in our Czech production plant in RT3 G ¾" (G 1" on request) Ø21 Ø

19 RT3T, RT3L and RT3S Thermostatic Draft Regulators RT3T Ø25 G ¾" Ø21 Ø RT3L G ¾" (G 1" on request) Ø21 Ø RT3S G ¾" (G 1" on request) Ø21 Ø Code RT3 RT3T RT3L RT3S

20 Regulus spol. s r.o., Czech Republic Do Koutů 1897/3, Praha 4 Tel.: , Fax: sales@regulus.cz Web: v1.1-03/2012

1 DESCRIPTION OF THE APPLIANCE

1 DESCRIPTION OF THE APPLIANCE 1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

HEAT INTERFACE UNITS (Modular)

HEAT INTERFACE UNITS (Modular) HEAT INTERFACE UNITS The Rhico T Fire Modular is probably the most versatile HIU available, the basic unit is a indirect heating only module incorporating a circulation pump on the secondary circuit. (A

More information

INTEC Engineering GmbH Heating Solutions for the Marine Industry

INTEC Engineering GmbH Heating Solutions for the Marine Industry INTEC Engineering GmbH Heating Solutions for the Marine Industry Thermal Oil Heaters Heating Solutions for the Marine Industry Compared to conventional plants using hot water or steam, thermal oil as a

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009 Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25

More information

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions

More information

Laddomat 21 Charging Unit

Laddomat 21 Charging Unit Laddomat 21 Charging Unit Part.No. 11 23 78 User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting

More information

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE Page 1 of 9 PURPOSE Steam is the most commonly used heating medium for maintaining process temperatures. Compared to other heating media, steam contains a significant amount of heat energy, and this heat

More information

Laddomat 21. For accumulation when using a wood-fired boiler. Picture 1. The wood-fired boiler is is connected to to. accumulator tank with bypass

Laddomat 21. For accumulation when using a wood-fired boiler. Picture 1. The wood-fired boiler is is connected to to. accumulator tank with bypass Picture 1 For accumulation when using a wood-fired boiler The wood-fired boiler is is connected to to an accumulator tank with bypass and dwh with......... Laddomat 21 and this is is how it it works...

More information

building engineering services association specification for: Domestic Heating www.thebesa.com

building engineering services association specification for: Domestic Heating www.thebesa.com building engineering services association specification for: Domestic central Heating installation www.thebesa.com building engineering services association acknowledgments Guide to good practice: Domestic

More information

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................

More information

Overheating limit control

Overheating limit control Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating

More information

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2 WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

SIBIR MANUAL V110 KE. English page 5 RKE - 1D 822 70 66-02

SIBIR MANUAL V110 KE. English page 5 RKE - 1D 822 70 66-02 SIBIR MANUAL RKE - 1D V110 KE English page 5 822 70 66-02 2 1 A. Flue tube E. Adapter I. Thermostat B. Flue baffle F. Burner base J. Lever arm C. Control knob G. Lamp glass D. Fuel gauge H. Lamp glass

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:

More information

Fully Pumped Systems

Fully Pumped Systems Fully Pumped Systems (also see the picture gallery and System Basics) The term for any boiler that uses a pump to move all the heat from the boiler to every part of the system is fully pumped. As a rule

More information

Dehumidifier D 850E. - Instruction manual version 02

Dehumidifier D 850E. - Instruction manual version 02 Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing

More information

FLASH TANK ECONOMIZER PRODUCT GUIDE

FLASH TANK ECONOMIZER PRODUCT GUIDE FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.

More information

Direct steam injection humidifiers

Direct steam injection humidifiers Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature

More information

Odyssey of the Mind Technology Fair. Simple Electronics

Odyssey of the Mind Technology Fair. Simple Electronics Simple Electronics 1. Terms volts, amps, ohms, watts, positive, negative, AC, DC 2. Matching voltages a. Series vs. parallel 3. Battery capacity 4. Simple electronic circuit light bulb 5. Chose the right

More information

Laddomat 21 Charging package

Laddomat 21 Charging package Laddomat 21 Charging package Part.No. 11 23 72 1 User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out

More information

stainless steel pre-assembled manifolds

stainless steel pre-assembled manifolds TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and

More information

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction

More information

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50

More information

Spare Parts List M96A.24SM/B M96A.28SM/B

Spare Parts List M96A.24SM/B M96A.28SM/B *16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.

More information

LK Electric Boiler - 4,5

LK Electric Boiler - 4,5 LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease The NEW Greenstar i innovative intuitive improved performance installation ease A NEW look, NEW features and a NEW NAME for the UK s best selling boiler, the Greenstar i Junior 1 Introducing the new Greenstar

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005 CUENOD Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CELTIC RSc b R8202395-02EN - Edition 02-21/04/2005 Boilers Solar Panel 69214511 31 CELTIC

More information

High efficiency, cast-iron gas boiler

High efficiency, cast-iron gas boiler SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification

More information

SHOWERS 85-100 SHOWERS

SHOWERS 85-100 SHOWERS SHOWERS 85-100 85 SHOWERS SHOWER HEADS 87 NEPTUNE 89 SHOWER PANEL SERIES PERFECT TIME SHOWER PANEL SERIES 91 NEPTUNE 1042T 93 PERFECT TIME 1042T 94 NEPTUNE MEDICAL 95 TOUCH SH 1000T 96 NEPTUNE 1032 97

More information

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling STOVE-BOILER FOR SOLID FUELS Directions for use and assembling Sadrºaj 1 Technical data 2 1.1 Boiler properties TEMY PLUS P 25............................. 3 1.2 On Product............................................

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

Heating and air-conditioning industry

Heating and air-conditioning industry Heating and air-conditioning industry Innovative solutions for your success Dear Readers, We all prefer a nice warm room. As manufacturers of heating and air-conditioning systems, you know just how important

More information

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................

More information

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30 INSTRUCTION MANUAL FOR WB/WBS 3, 4, 5, 7, 8, 11, 14, 30 WATER BATH PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

Boiler Preparation, Start-Up and Shutdown

Boiler Preparation, Start-Up and Shutdown Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.

More information

Boiler Plan II Table of Contents

Boiler Plan II Table of Contents Cover Page Table Of Contents Introduction Parts List Additional Materials Assembly instructions Drawings 1-15 Boiler Plan II Table of Contents Introduction This will be a very rewarding project, if you

More information

TECHNICAL SPECIFICATION TYPE ATESO ALFA

TECHNICAL SPECIFICATION TYPE ATESO ALFA Page: 1 of 5 TECHNICAL SPECIFICATION TYPE ATESO ALFA 1. GENERAL 1.1. Make (trade name of manufacturer): BRANO a.s. 1.2. Type and general commercial description(s): ATESO ALFA 1.2.1 1.2.2. Variants: Versions:

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Factory owners must ensure the boiler is:

Factory owners must ensure the boiler is: Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised

More information

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet

More information

Wall boiler spare parts

Wall boiler spare parts SAUNIER Disconnector see page.14 Wall boiler spare parts Saunier Duval/ Chaffoteaux/MTS/ ELM > CHAFFOTEAUX Printed Circuit see page.39 SD Substituted spare parts Saunier Duval Description New ref Old ref

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/ CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------

More information

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation

More information

Commercial Gas Water Heater

Commercial Gas Water Heater Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service

More information

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4 Henco Snelselectie kaart EN IMPORTANT! Before starting work the fitter must carefully read this installation and operation manual, understand and observe its conditions. The water floor heating control

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions Part No. 130009 Iss. 12 August 2004 Elson www.elsonhotwater.co.uk Open Vented Thermal Store providing mains pressure hot water heated by electricity Installation, Servicing and User's Instructions Read

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

Data sheet ECC 12 and 22

Data sheet ECC 12 and 22 Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe

More information

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program. MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

MODEL 300505 INSTALLATION INSTRUCTIONS

MODEL 300505 INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation) PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SOLAR HEATING SYSTEMS. www.orkli.com

SOLAR HEATING SYSTEMS. www.orkli.com SOLAR HEATING SYSTEMS www.orkli.com // 2 Orkli is one of the main European manufacturers of components for household appliances and innovative solutions for the comfort sector. Its corporate activity is

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Refrigerated Air Dryers. Catalogue

Refrigerated Air Dryers. Catalogue Refrigerated Air Dryers Catalogue GB Why use a refrigerated dryer? Humidity is a component of atmospheric air, which can be found in the compressed air distribution systems and the machines that use the

More information

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced

More information

TOBY DVR5 OIL CONTROL & SAFETY VALVE

TOBY DVR5 OIL CONTROL & SAFETY VALVE TOBY DVR5 OIL CONTROL & SAFETY VALVE TECHNICAL HANDBOOK Principle of Operation The Toby DVR5 Oil Control Valve is a multi function unit for maintaining a constant oil level, regulating the oil flow and

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55 Frequently Asked Questions Air Top Diesel Heaters 2000STC, Evo 40 & Evo 55 Question 1 What power outputs are the heaters available in? There are 3 models 2kW, 4kW and 5.5kW Question 2 What voltage are

More information

www.the Floor Heating Warehouse.co.uk

www.the Floor Heating Warehouse.co.uk www.the Floor Heating Warehouse.co.uk Underfloor Heating Installation Guide (Grundfoss Pump System) General Overview: Our water based underfloor heating system can be installed by your own plumber or heating

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause

More information

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED High Efficiency Condensing Boilers Proven Reliability, American-Made Home Heating Comfort. Look for this logo throughout this literature to see the unique features that set U.S. Boiler Company apart from

More information

NFPA31FuelOilPiping 1 Revised 3-1-11

NFPA31FuelOilPiping 1 Revised 3-1-11 NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions The world s best selling supply unit. The right choice for any conditions AB-c arine Compact Heavy Fuel Oil supply unit This series of marine AB-c Heavy Fuel Oil () supply units is developed to combine

More information

SMD Rework Station TABLE OF CONTENTS

SMD Rework Station TABLE OF CONTENTS SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating

More information

UNDERSTANDING CENTRAL HEATING SYSTEMS

UNDERSTANDING CENTRAL HEATING SYSTEMS UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic

More information

Gas-Fired, Residential Storage Type Water Heaters

Gas-Fired, Residential Storage Type Water Heaters Consulting, Resource, Education, Training, and Support Services for Home Inspectors A candle loses no light when it lights another candle. Gas-Fired, Residential Storage Type Water Heaters Most inspectors

More information

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL Siniša Stojan, Ph.D. student Damir Dražić, Ph.D. student Brodotrogir, HR - 21220 Trogir, Croatia sinisa.stojan@brodotrogir.hr,

More information

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

Volvo Penta Quality Line Marine Water Heaters. Owners Manual Volvo Penta Quality Line Marine Water Heaters Owners Manual Mounting Instructions Congratulations on your choice of a new QL Water Heater. A choice that will help you bring out the best in boating pleasure.

More information

User's Instructions. Alpha HE CB25/33 and HE SY25

User's Instructions. Alpha HE CB25/33 and HE SY25 User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Oil - kerosene burners

Oil - kerosene burners Installation, use and maintenance instructions Oil - kerosene burners One stage operation CODE MODEL TYPE 3747469 G0 474T5 90 (0) - 05/008 TECHNICAL FEATURES Thermal power output 95 3 kw 8 8 kg/h Fuel

More information