Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that.

Size: px
Start display at page:

Download "Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that."

Transcription

1 Set Free Modular FSXN Engineering for tomorrow. And the tomorrow after that.

2 0 0 Introducing a new addition to Hitachi s Set Free range of VRF air conditioning units - enhancing efficiency and user experience Hitachi air conditioning successfully meets installer and customer demands offering greater functionality, control and cost savings There is increasing demand for a holistic approach to air conditioning in modern offices units that are capable of simultaneously cooling and heating, adapting to the different seasons and various temperature requirements of rooms. Customers also want to save time, money and space with their air conditioning and have the flexibility to extend or modify their air conditioning set-up to suit changing needs. And of course there is a growing demand for air conditioning to be as environmentally friendly as possible enabled through an air-conditioning management system that makes it easier for users to have simple, effective control of their air conditioning units to avoid unnecessary energy wastage, including overheating, overcooling and unattended operation. To meet and exceed these important requirements, Hitachi has developed the Set Free FSXN air conditioning system. Needs of end user Heat recovery operation Energy efficient Greater user control Flexibility to extend system Needs of consultants Time saving with equipment layout design Flexible, modular system designs Intelligent controls Needs of contractor and installer Modular and lightweight for quicker (or phased) installations Increased piping lengths for flexibility Set Free FSXN Capable of heat recovery and -pipe heat pump operations Set Free FSXN benefits Compatible with Hitachi s system free indoor units and heat recovery ventilation units Hitachi s outdoor units feature a heat recovery operation system as well as a -pipe heat pump operation system. This avoids the need for review work when designing the equipment layout, while reducing the workload and time spent installing the units on site. Wide product range - All models (8 to 54HP) When used as a heat recovery operation system Set Free FSXN (Module Type) When used as a -pipe heat pump operation system Energy saving - Heat recovery and DC Inverter Driven Flexibility of installation - Compact and lightweight design and flexible refrigerant piping Comfort and reliability - Capable of impressively low noise levels with noise reduction preference mode (option) Control by Network System Off coil temperature control CH units pipes Heat Recovery and -pipe heat pump operations Common Unit 8 to 54HP 4 models (Outdoor unit: 6 models) The heat recovery and -pipe heat pump operation systems cannot be switched over after installation is complete. pipes

3 04 05 Heat recovery operation Heat recovery operation - the most important requirement Heat recovery operation system - meeting different air conditioning needs in the same building Temperature control in today s modern spaces is vitally important. There s increasing customer demand for the need to switch between cooling and heating, depending on time of day and external environmental conditions. And of course, equipment such as computers and terminal devices can also add to the heat in spaces. Therefore, heat recovery operation is often a top priority when considering air conditioning systems for buildings. To meet these needs, Hitachi has developed the Set Free FSXN, offering effective heat recovery operation. ased on our existing heat recovery operation system Set Free FXN - we have expanded the range; enhancing efficiency, reducing the dimensions and improving workability. As a result, Set Free FSXN offers superb energy-saving efficiency and better comfort. In office buildings The heat inside buildings is less likely to be released due to improvements in building structures, such as heat insulator performance and doubleglazed windows. Cooling is required throughout the year where there are lighting fixtures and IT equipment; equally other areas can be affected by ambient temperatures and sunshine, so either cooling or heating is required according to changes in the flow of heat. Compensate and adjust when there are hot and cold rooms in the same building, depending on the direction of sunshine. In commercial buildings Meeting Room Offices Control the air temperature separately from room to room because of different heating/ cooling requirements. Heat recovery operation is essential in commercial buildings where, for example, restaurants and shops co-exist. Handle changes in airconditioning needs (differences in cooling/heating requirements) due to changing tenants or the alteration of partitions. Restaurant Retail Manage rooms that need to be cooled all through the year. Reduce annual power consumption. In hotels Room temperatures should be set independently according to the personal preferences of the guests, with different requirements in the open public areas. Reception Guest Room

4 06 07 Heat Recovery Operation Heat recovery operation - significantly enhancing energy efficiency System configuration A heat recovery system offers high energy-saving efficiency by drawing heat from the rooms to be cooled, and effectively using it as a heat source for the rooms to be heated. Outdoor unit Refrigerant piping Transmission Existing system (-pipe heat pump operation) Heat recovery and -pipe heat pump operations common unit (auto-recognition). Max length: 65m Total length:,000m Height dfference: 50m Corresponding to H-LINK Max 64 refrigerant groups Max 60 indoor units 6HP heat radiation Multiple -pipe heat pump units are required when there are different air conditioning needs in one building. 6HP heat absorption Module type (external connection) Connectable Indoor Units Max: 64 units heat release Connection ratio: 50-0% heat release heat absorption ON OFF ON OFF Cooling with 50% capacity heat absorption Heating with 50% capacity Advanced system ( pipe heat pump operation) With the heat recovery operation, the heat is effectively used as a source of heating. 6HP heat release heat release heat absorption ON OFF Cooling with 50% capacity heat absorption Lower equipment cost and power consumption compared with existing system* * If the ratio of cooling and heating loads is 50:50, the power consumption of one heat recovery unit can cover the operation of two -pipe heat pump units. CH unit (heat recovery system only) Changeover box for heat recovery application Compact and light design Dimensions: 0(W) x 9(H) x 4(D) mm Weight: 7kg Integrated Remote Controller

5 08 09 Product range Choose from a selection of 6 models used individually or in combinations (8 to 54HP) all integrating heat recovery and heat pump operation to suit customer requirements. Indoor unit 0.8HP.0HP.HP.5HP.8HP.0HP.HP.5HP.0HP 4.0HP 5.0HP 6.0HP 8.0HP 0.0HP Hitachi s Set Free FSXN Series offers 6 types of modular outdoor units and 0 types (5 models) of indoor units. y combining units from a wide selection of models, you can create a tailored air conditioning environment to satisfy your specific building conditions. Outdoor unit capacity has been extended up to 54HP by combining the outdoor units (max. ). This system can provide heat recovery operation or -pipe heat pump operation systems as follows: Outdoor unit Mini in-the-ceiling In-the-ceiling (Low Height) In-the-ceiling A RAS 8.0FSXN ~.0FSXN Outer dimensions Width: 950 mm Depth: 765 mm Height:,70 mm Net weight 0 kg RAS 4.0FSXN ~ 8.0FSXN Outer dimensions Width:,0 mm Depth: 765 mm Height:,70 mm Net weight 4 & 6HP: 95 kg 8HP: 5 kg Mini 4-way cassette 4-way cassette -way cassette Wall mounted A A A A Ceiling 8HP 4HP 0HP HP 0HP 6HP 4HP Floor mounted HP 8HP 6HP Floor-concealed A A A Capacity available with dip switch setting capacity range (HP) Adjustable by dip switch setting 8HP 8HP 44HP 50HP System equipment 0HP 40HP 46HP 5HP 50m /h 500m /h 800m /h,000m /h,500m /h,000m /h,000m /h HP 4HP 48HP 54HP 4HP 6HP Refer to General data for information on the combination of outdoor units. Total heat exchanger

6 0 Energy-saving and Comfort Energy-saving and comfort - - Energy-saving technology delivers outstanding performance Refrigerant cycle and control achieve a high level of efficiency and energy-saving performance. EER comparison for cooling operation [ HP (50Hz) ] % 00% 0% 00% 04% 4% % 00% 0% 00% 04% COP comparison for heating operation [ HP (50Hz) ] FXN FSN SET-FREE FSXN FXN FSN SET-FREE FSXN Comparison when COP of FXN series is 00%. For a single outdoor unit The cooling and heating performances shown are the values when combined with our specified indoor units % 4.04 Capacity control by Hz steps Performance is greatly improved by the high efficiency DC inverter compressor and 00% load compressor, and lossless energy-saving operation is achieved (depending on the building). Wide operating range The Set Free FSXN can operate within a wide range of ambient conditions, extending the flexibility of the installation. Self-demand control A newly developed self-demand function has largely improved energy-saving capabilities. Since the current is self-detected and demand control performed automatically, no signal wiring work is required. Conventional demand control using demand signals is also available and you can select various operations as required. Control Capacity Power consumption 00% 0% Max. 0Hz~00Hz 80Steps No. Inverter Cooling Load Power consumption Min. Power setting Selectable from 00%, 80%, 70% and 60% of the rated power consumption for cooling operation. Morning Control Capacity 00% 0% Heating -0 C Max. 80Steps No. Inverter 5 C No. compressor 0Hz~00Hz Cooling Load Cooling Excessive -5 C power supply 4 C consumption exceeding the power setting range is restricted. Min Power setting Selectable from 00%, 80%, 70% and 60% of the rated power consumption for cooling operation. Excessive power supply consumption exceeding the power setting range is restricted. Maximum efficiency is secured within the power setting NEW range. Wave function Night Operation hours Maximum efficiency is secured within the power setting NEW range. Wave function Cutting-edge DC inverter high pressure scroll compressor Intermediate pressure performance is greatly improved with the new compression mechanism s release valve and optimising orbiting scroll-lifting force. This increases the system s energy efficiency. The release valve prevents the occurrence of over-compression and the orbiting scroll lifting force optimisation minimises leakage loss. Wave mode Morning Operation hours Wave mode turns demand control ON and OFF alternately at intervals of 0 or 0 minutes. While power consumption is reduced temperature changes are minimised to maintain a comfortable room temperature. Without demand control Average power consumption That's the demand effect! With demand control Night Average power consumption Power consumption Power setting Power consumption Power setting (Min.) (Min.)

7 Flexibility Flexibility of of of Installation Flexibility of Installation Flexible installation Compact and lightweight design Set-Free FSXN outdoor unit 8HP: RAS-8FSXN 0HP: RAS-0FSXN HP: RAS-FSXN 950mm 950mm 950mm 950mm Even the largest unit (8HP model) can be carried in an elevator Elevator Door opening: 800mm Depth:,50mm 4HP: RAS-4FSXN 6HP: RAS-6FSXN 8HP: RAS-8FSXN,0mm,0mm Ease and flexibility of installation is further enhanced by the outdoor unit s lightweight and compact design. 8HP RAS-8FSN (8FXN) 460kg 460kg (570kg) (570kg) 460kg (570kg),90mm,90mm,745mm,745mm,745mm 750mm 750mm,90mm,745mm 750mm Transportation and handling using elevator An elevator can be used to transport the outdoor unit separately.,745mm 8HP RAS-8FSXN 5kg 5kg 5kg,0mm,0mm,0mm,0mm,0mm Installation space: Reduced by 5% Weight: Reduced by % (45%) Increased flexibility of refrigerant piping work Improved flexibility of design by increasing the pipe length to 65m maximum (equivalent length of 90m) in FSXN series. 4 Max. piping length: 65m* etween first branch and indoor unit: 90m or less Height difference between highest and lowest indoor units: 5m or less Height difference between outdoor and indoor units: 50m** 5 Max. length after branch: 40m Total maximum piping length Maximum piping length Distance between first branch and indoor unit Maximum piping length after branch Current model (FSN) Connectable to 64 indoor units 4 New model (FSXN) 00m,000m 50m 40m 0m 65m 90m 40m * For 00m or more, the pipe diameter will be one size larger. ** In case the outdoor unit is installed at a higher level than indoor units. If the outdoor unit is installed lower than indoor units, the maximum height difference is 40m. The number of connectable indoor units has been increased to 64 maximum* Connection ratio: 50-0% HP Maximum number of connectable Indoor units Maximum number of connectable Indoor units Current models New model FSN() Series FSN Series FSXN Series HP Current models New model FSN() Series FSN Series FSXN Series For a system in which all indoor units are operated simultaneously, the maximum total capacity will be 00%. Determine the number of indoor units carefully so that a problem such as decreased outlet air temperature will not occur. Refer to Technical Catalogue for more details. Compared to indoor units of over.5hp, indoor units of 0.8 and.0hp are set with higher air flow. Do not install these units in a place where a cold draft may occur during heating operation. Determine the usage environment and installation location carefully. *Maximum number of connectable indoor units. Values may be varied in accordance with the total length of refrigerant piping. Refer to the technical manual for more details.

8 4 5 Other advanced technologies Rotational operation* to distribute load of outdoor units Regulating the operation time of each outdoor unit leads to load reduction on compressors**. During multiple unit operation, the same rotation frequency of inverter compressor results in an equivalent load on each compressor. Therefore, outdoor unit endurance is improved. Inverter compressor rotation frequency control Revolution of inverter of inverter compressor One unit operation One unit operation Low Low Revolution of inverter compressor Two units One unit operation Two operation units operation Operating Low load Three units Two units operation Three operation units operation Hi Operating Hi load Three units operation It is operated so that the revolution of the inverter compressor and may become the same. Revolution of Revolution of Operating load * At least outdoor units are required for this function. ** Comparison between rotation operation function and non-rotation operation function based on the same system. Emergency backup operation function The backup operation function prevents the system from coming to a complete stop when an outdoor unit failure occurs*. Emergency operation starts with the remote control switch after an alarm***. * At least outdoor units are required for this function. ** Emergency operation can be performed within 8 hours after unit stoppage. After 8 hours passed from unit stoppage, emergency operation can not be performed. *** Emergency operation can be performed when the specified alarm code occurs. Refer to Alarm Code for Emergency Operation. Hi Revolution of Revolution of Revolution of Revolution of At the time of compressor start-up, or when hours has passed from start of operation. Failed outdoor unit Press TEMP. simultaneously for seconds. Last time Last time This time This time Next time Next time x Last time This time Next time Even if one unit fails, the other can be operated continuously** x Emergency operation indication Emergency operation indication Emergency operation indication Noise reduction mode With the new noise reduction preference mode, the sound pressure level for a particular time zone can be set based upon the environment*. Therefore, the operation/management of air conditioners is facilitated in areas where the noise level at night time is restricted by laws and regulations. You can select from sound pressure levels Optional noise reduction function Setting from outdoor unit input and output function Setting (standard value - d) Setting (standard value - 5d) Setting (standard value - 8d) Sound pressure level (d) (Approx. Value**) * The range of performance and operation is restricted, because the rotation frequency of the compressor and outdoor fan is forcibly decreased. Target Capacity of Each Setting Noise Reduction Setting : 80% of Standard Capacity Noise Reduction Setting : 60% of Standard Capacity Noise Reduction Setting : 40% of Standard Capacity ** The table above shows an approximate value of 0HP. In some cases, the value may temporarily become higher than the approximate value in the table above due to operation control conditions. Automatic refrigerant assessment system Use this automatic assessment system to check whether or not the refrigerant amount is sufficient in one refrigerant cycle. Factors for judgement The appropriate refrigerant amount is calculated based upon the following data. Refrigerant cycle temperature Refrigerant saturation temperature Outdoor unit expansion valve data 4 Indoor unit data Setting example Low-sound operation during night time only by using timer Input signal * Input signal * Input signal * Input signal * Night time Night time Rotation Frequency Night time Night time 5d equivalent rotation 5d equivalent rotation 5d equivalent rotation 5d equivalent rotation Outdoor Unit Fan Night time Night time Rotation Frequency Night time Night time 5d equivalent rotation 5d equivalent rotation 5d equivalent rotation 5d equivalent rotation Time Time Time * Perform the electrical wiring work on site when setting input Time signal Refrigerant cycle configuration [schematic diagram] Pressure sensor Pressure Refrigerant leakage sensor P occurs Thermistor P Thermistor Thermistor Measure adequate refrigerant quantity Accumulator P Pressure sensor Adjustment Adjustment Accumulator Correct Incorrect Correct Incorrect Adjustment Correct Incorrect EMG is displayed on the LCD at the remote control switch, and emergency operation starts. Work quantity improvement Work quantity improvement Work quantity improvement Overcooler Overcooler Outdoor heat Overcooler exchanger Outdoor heat exchanger Outdoor heat exchanger

9 6 7 General data RAS-8FSXN RAS-0FSXN RAS-FSXN RAS-4FSXN RAS-6FSXN RAS-8FSXN RAS-0FSXN RAS-FSXN RAS-4FSXN RAS-6FSXN RAS-8FSXN RAS-0FSXN (RAS-8FSXN + RAS-FSXN) (RAS-8FSXN + RAS-4FSXN) (RAS-0FSXN + RAS-4FSXN) (RAS-FSXN + RAS-4FSXN) (RAS-4FSXN + RAS-4FSXN) (RAS-4FSXN + RAS-6FSXN) Power supply (kw) AC Ø, 400V/50Hz (80-45V / 50Hz), 80V/60Hz, 0V/60Hz AC Ø, 400V/50Hz (80-45V / 50Hz), 80V/60Hz, 0V/60Hz Nominal capacity (kw) EER/COP (50/60Hz) Cooling Heating Cooling.85 / /.79.4 /.4.5 /.. /.9.7 /.5.58 /.58.6 /.58.7 /.5.8 /.6.5 /..4 /.0 Heating 4.7 / / / / /.9.8 /.85.8 / / / / / /.9 Cabinet color (munsell code) Natural grey (.0Y 8.5/0.5) Natural grey (.0Y 8.5/0.5) Maximum sound pressure level d(a) Outer Dimensions (mm) & Weight (Kg) Overall A scale Night-shift Height Width Depth Weight Refrigerant (flow control) R40A (micro-computer control expansion valve) R40A (micro-computer control expansion valve) Model E656DHD E656DHD + E655DH E656DHD + E855DH E656DHD + E656DHD E656DHD + E656DHD + E655DH E656DHD + E655DH + E656DHD + E655DH (Hermetic (scroll)) Quantity Motor output (pole) 4.8(4) 6.0(4) 7.(4) 4.8(4) + 4.4() 6.0(4) + 4.4() 6.0(4) + 5.6() 4.8(4) + 7.(4) 4.8(4) + 4.8(4) + 4.4() 6.0(4) + 4.8(4) + 4.4() 4.8(4) + 4.8(4) + 4.4() 4.8(4) + 4.4() + 4.8(4) + 4.4() 4.8(4) + 4.4() + 6.0(4) + 4.4() Heat exchanger Multi-pass cross-finned tube Multi-pass cross-finned tube Liquid line Ø9.5* (/8in) Ø.7* (/in) Ø5.88* (5/8in) Ø9.05* (/4in) Main refrigerant piping cooling/heating pipes Ø9.5 - Ø.7 (/8in - /in) Ø.7 - Ø5.88 (/in - 5/8in) Ø Ø9.05 (5/8in - /4in) Ø Ø. (/4in - 7/8in) changeover operation system (mm (in)) Gas line Ø9.05* (/4in) Ø.* (7/8in) Ø5.4* (in) Ø8.6* ( /8in) Ø8.6* ( /8in) Ø.75* ( /4in) pipes Ø Ø. (/4in - 7/8in) Ø. - Ø5.4 (7/8in - in) Ø5.4 - Ø8.6 (in - /8in) Ø8.6 - Ø.75 ( /8in - /4) Ø8.6 - Ø.75 ( /8in - /4) Ø.75 - Ø4.9 ( /4in - /8) Liquid line Ø9.5* (/8in) Ø.7* (/in) Ø5.88* (5/8in) Ø9.05* (/4in) pipes Ø9.5 - Ø.7 (/8in - /in) Ø.7 - Ø5.88 (/in - 5/8in) Ø Ø9.05 (5/8in - /4in) Ø Ø. (/4in - 7/8in) Main refrigerant piping cooling/heating Gas line low pres. Ø9.05* (/4in) Ø.* (7/8in) Ø5.4* (in) Ø8.6* ( /8in) Ø8.6* ( /8in) Ø.75* ( /4in) simultaneous operation system (mm (in)) pipes Ø Ø. (/4in - 7/8in) Ø. - Ø5.4 (7/8in - in) Ø5.4 - Ø8.6 (in - /8in) Ø8.6 - Ø.75 ( /8in - /4) Ø8.6 - Ø.75 ( /8in - /4) Ø.75 - Ø4.9 ( /4in - /8) Gas line high pres. Ø5.88* (5/8in) Ø9.05* (/4in) Ø.* (7/8in) Ø.* (7/8in) Ø5.4* (in) Ø8.6* ( /8in) pipes Ø Ø9.05 (5/8in - /4in) Ø Ø. (/4in - 7/8in) Ø. - Ø5.4 (7/8in - in) Ø. - Ø5.4 (7/8in - in) Ø5.4 - Ø8.6 (in - /8in) Ø8.6 - Ø.75 ( /8in - /4) Refrigerant charge (Kg) Height,895, Packing dimensions (mm) Width 990,50, Depth Approximate packing measurement (m ) NOTES:. The cooling and heating performances are the values when combined with our specified indoor units. (00% rating) Cooling operation conditions Heating operation conditions Indoor air inlet temperature: 7 C D (80 F D) Indoor air inlet temperature: 0 C D (68 F D) 9.0 C W (66. F W) Outdoor air inlet temperature: 7 C D (45 F D) Outdoor air Inlet temperature: 5 C D (95 F D) 6 C W (4 F W) Piping length: 7.5 meters / Piping lift: 0 meter NOTES:. The sound pressure is based on the following conditions. meter from the unit service cover surface, and.5 meters from floor level. The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately ~ d. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.. *If the specified main refrigerant piping on the table is not available on site, follow the allowable piping size in parentheses. When using the main refrigerant piping indicated in parentheses, prepare an appropriate reducer on site. 4. Except for the specified combination in the table (0~0HP), there is no other combination of the base unit. 5. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 0mm.

10 8 9 General data RAS-FSXN RAS-4FSXN RAS-6FSXN RAS-8FSXN RAS-40FSXN RAS-4FSXN RAS-44FSXN RAS-46FSXN RAS-48FSXN RAS-50FSXN RAS-5FSXN RAS-54FSXN (RAS-6FSXN + RAS-6FSXN) (RAS-6FSXN + RAS-8FSXN) (RAS-8FSXN + RAS-8FSXN) (RAS-FSXN + RAS-FSXN + RAS-4FSXN) (RAS-FSXN + RAS-FSXN + RAS-6FSXN) (RAS-FSXN + RAS-FSXN + RAS-8FSXN) (RAS-FSXN + RAS-4FSXN + RAS-8FSXN) (RAS-FSXN + RAS-6FSXN + RAS-8FSXN) (RAS-FSXN + RAS-8FSXN + RAS-8FSXN) Power supply (kw) AC Ø, 400V/50Hz (80-45V / 50Hz), 80V/60Hz, 0V/60Hz AC Ø, 400V/50Hz (80-45V / 50Hz), 80V/60Hz, 0V/60Hz (RAS-4FSXN + RAS-8FSXN + RAS-8FSXN) (RAS-6FSXN + RAS-8FSXN + RAS-8FSXN) (RAS-8FSXN + RAS-8FSXN + RAS-8FSXN) Nominal capacity (kw) EER/COP (50/60Hz) Cooling Heating Cooling. /.9.0 /.7.7 /.5.9 /.8.4 /.. /..7 /.4.6 /.5.4 /.. /.. /.0.7 /.5 Heating.90 /.9.85 /.89.8 / /.88.7 /.7.65 / /.75.7 /.7.74 / / / / 4.0 Cabinet color (munsell code) Natural grey (.0Y 8.5/0.5) Natural grey (.0Y 8.5/0.5) Maximum sound pressure level d(a) Outer dimensions (mm) & Weight (Kg) Overall A scale Night-shift Height,70,70 Width,440, 50, 50,40,670 Depth Weight Refrigerant (flow control) R40A (Micro-computer control expansion valve) R40A (Micro-computer control expansion valve) (hermetic scroll) Model E656DHD + E655DH + E656DHD + E655DH E656DHD + E655DH + E656DHD + E855DH E656DHD + E855DH + E656DHD + E855DH E656DHD + E656DHD + E656DHD + E655DH E656DHD + E656DHD + E656DHD + E855DH E656DHD + E656DHD + E655DH + E656DHD + E855DH E656DHD + E656DHD + E855DH + E656DHD + E855DH E656DHD + E655DH + E656DHD + E855DH + E656DHD + E855DH Quantity Motor output (pole) 6.0(4) + 4.4() + 6.0(4) + 4.4() 6.0(4) + 4.4() + 6.0(4) + 5.6() 6.0(4) + 5.6() + 6.0(4) + 5.6() 7.(4) + 7.(4) + 4.8(4) + 4.4() 7.(4) + 7.(4) + 6.0(4) + 4.4() 7.(4) + 7.(4) + 6.0(4) + 5.6() 7.(4) + 4.8(4) + 4.4() + 6.0(4) + 5.6() 7.(4) + 6.0(4) + 4.4() + 6.0(4) + 5.6() 7.(4) + 6.0(4) + 5.6() + 6.0(4) + 5.6() 4.8(4) + 4.4() + 6.0(4) + 5.6() + 6.0(4) + 5.6() 6.0(4) + 4.4() + 6.0(4) + 5.6() + 6.0(4) + 5.6() Heat exchanger Multi-pass cross-finned tube Multi-pass cross-finned tube Liquid line Ø9.05* (/4in) Ø9.05* (/4in) Main refrigerant piping cooling/heating pipes Ø Ø. (/4in - 7/8in) Ø Ø. (/4in - 7/8in) changeover operation system (mm (in)) Gas line Ø.75* ( /4in) Ø8.* ( /in) Ø8.* ( /in) pipes Ø.75 - Ø4.9 ( /4in - /8) Ø8. - Ø4. ( 5/8in) Ø8. - Ø4. ( 5/8in) Liquid line Ø9.05* (/4in) Ø9.05* (/4in) pipes Ø Ø. (/4in - 7/8in) Ø Ø. (/4in - 7/8in) Main refrigerant piping cooling/heating Gas line low pres. Ø.75* ( /4in) Ø8.* ( /in) Ø8.* ( /in) simultaneous operation system (mm (in)) pipes Ø.75 - Ø4.9 ( /4in - /8) Ø8. - Ø4. ( 5/8in) Ø8. - Ø4. ( 5/8in) Gas line high pres. Ø5.88* (5/8in) Ø9.05* (/4in) Ø.* (7/8in) Ø.75* ( /4in) pipes Ø Ø9.05 (5/8in - /4in) Ø Ø. (/4in - 7/8in) Ø. - Ø5.4 (7/8in - in) Ø.75 - Ø4.9 ( /4in - /8) Refrigerant charge (Kg) Height Packing dimensions (mm) Width Depth Approximate packing measurement (m ) E656DHD + E855DH + E656DHD + E855DH + E656DHD + E855DH 6.0(4) + 4.4() + 6.0(4) + 5.6() + 6.0(4) + 5.6() NOTES:. The cooling and heating performances are the values when combined with our specified indoor units. (00% rating) Cooling operation conditions Heating operation conditions Indoor air inlet temperature: 7 C D (80 F D) Indoor air inlet temperature: 0 C D (68 F D) 9.0 C W (66. F W) Outdoor air inlet temperature: 7 C D (45 F D) Outdoor air inlet temperature: 5 C D (95 F D) 6 C W (4 F W) Piping length: 7.5 meters / Piping lift: 0 Meter NOTES:. The sound pressure is based on the following conditions. meter from the unit service cover surface, and.5 meters from floor level. The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately ~ d. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.. *If the specified main refrigerant piping on the table is not available on site, follow the allowable piping size in parentheses. When using the main refrigerant piping indicated in parentheses, prepare an appropriate reducer on site. 4. Except for the specified combination in the table (~54HP), there is no other combination of the base unit. 5. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 0mm.

11

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73 MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

NEW 3-PIPE ECOi MF2 SERIES

NEW 3-PIPE ECOi MF2 SERIES NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal Utopia Split Systems Models Utopia ES (7.1-14 kw) Utopia IVX (7.1-30 kw) Utopia DC Inverter (5-14 kw) Utopia Fixed Speed (6.3-12.5 kw) Utopia Centrifugal (12.5-25 kw) Contents Company Profile 4 Utopia

More information

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE AquaFREE system Technical Catalogue Outdoor units: RAS(3~5)HVRNE RAS(4/5)HRNE Indoor units: RWM(3~5)FSN1E RWM(3~5)FSN1E(4.5/6)H(1/3) RWM(3~5)FSN1ES1 RWM(3~5)FSN1E(4.5/6)SH(1/3) Specifications in this

More information

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW utopia DC Inverter 7kW-14kW G8 5kW-25kW Split Systems Contents Company profile 4 Product range overview 6 Features and benefits 8 DC Inverter 12 Utopia G8 24 Utopia centrifugal 40 Total heat exchanger

More information

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) room air conditioners Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) Contents Company profile 4 Product range overview 6 Standards and quality certificates 8

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

GREE, MAKING BETTER AIR CONDITIONERS

GREE, MAKING BETTER AIR CONDITIONERS GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI Add:Jinji RD.Qianshan Zhuhai 519070,Guangdong,China Tel: (+86-756)8614883 Fax: (+86-756)8627140 Email: gree@gree.com.cn http://www.gree.com.cn Heat Pump Water Heater

More information

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC

More information

14. Troubleshooting Guide

14. Troubleshooting Guide 14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hot Water. Heat pump water heaters. Residential and Commercial R410a Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,

More information

How To Make A High Efficiency Thermostat

How To Make A High Efficiency Thermostat Zoning with Variable Speed Mini-Split Systems Fujitsu Service Training Welcome - Thank you for attending Did you know? In 1940 only 42% of homes in the US had central heating In 1970 20% of homes had central

More information

Air Conditioning For Large Buildings

Air Conditioning For Large Buildings Air Conditioning For Large Buildings Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

Versati Air to Water Heat Pump

Versati Air to Water Heat Pump Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating

More information

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings. 1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Split units TH with hermetic compressors

Split units TH with hermetic compressors Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split

More information

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER IN-CEILING CASSETTE Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER TECHNOLOGY PFC Control in Power Input DC Inverter

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets 2 Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets - Extending Use of New Heat Pump System in Cold Regions

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump your comfort. our world. Daikin Altherma Hybrid Heat Pump Smart heating technology for the best of both worlds Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Forward thinking About

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

FTXS. Wall Mount Heat Pump or Cooling Only

FTXS. Wall Mount Heat Pump or Cooling Only FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump Daikin Altherma Hybrid Heat Pump Smart technology for the best of both worlds NATIONAL HEAT PUMP 19 JUNE 2014 ICC BIRMINGHAM WINNER Forward thinking Now is the time to rethink the way we heat our homes

More information

FCQ. Roundflow Cassette Heat Pump or Cooling Only

FCQ. Roundflow Cassette Heat Pump or Cooling Only FCQ Roundflow Cassette Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FCQ roundflow cassette SkyAir systems are ideal for open plan applications where variances in temperature and airflow

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM J.S. Hu, Philip C.W. Kwong, and Christopher Y.H. Chao Department of Mechanical Engineering, The Hong Kong University of Science and Technology Clear Water Bay,

More information

YUTAKI S. Domestic Heating

YUTAKI S. Domestic Heating YUTAKI S ECOLOGY & COMFORT OUTDOOR UNIT RAS 3HVRNME-AF YUTAKI-S MODULE RWM 2~10.0HFSN3E The Yutaki S heat pump is the ideal solution both in new installations and refurbishments. Its exceptional performance

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

AIR-CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,

More information

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

The ABB i-bus KNX Room Master Concept Your first step into the KNX world The ABB i-bus KNX Room Master Concept Your first step into the KNX world The Room Master Concept 1 New Step 1,000 New Options You specialize in installing electrical systems. With the ABB Room Master,

More information

The natural ombination

The natural ombination The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,

More information

Refrigeration Compressed Air Dryer Buran Ultrapulse

Refrigeration Compressed Air Dryer Buran Ultrapulse Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of

More information

How To Design A Building In New Delhi

How To Design A Building In New Delhi ENERGY EFFICIENT HVAC DESIGN FOR COMPOSITE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce energy consumption

More information

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology your comfort. our world.» Up to 70% energy saving with BLDC motor technology» Instant adjustment to temperature and relative humidity changes» Low noise levels» Highly flexible solutions Fan Coil Units

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

DM13-01.01.01en. Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3

DM13-01.01.01en. Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3 DM13-01.01.01en Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3 Contents Part 1 General Information... 1 Part 2 Selection

More information

FBQ. DC Duct Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat

More information

FHQ. Ceiling Suspended Heat Pump or Cooling Only

FHQ. Ceiling Suspended Heat Pump or Cooling Only FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this

More information

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing

More information

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities. Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities. More Freedom to Administrators Connectable up to 128 Indoor Unit Groups (256 indoor

More information

ECO-AIR AIR CONDITIONING www.northamericanhvac.com

ECO-AIR AIR CONDITIONING www.northamericanhvac.com INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...

More information

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and 1 Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

emura Form. redefined.

emura Form. redefined. emura Form. function. redefined. IT S ALL ABOUT DESIGN if award Daikin Europe N.V. is proud to announce that Daikin Emura has been awarded an if Product Design Award for 2010. For 56 years, the if product

More information

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

ASTACEA4 Inspect complex/central air conditioning systems

ASTACEA4 Inspect complex/central air conditioning systems Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

A/C refrigerant system, overview

A/C refrigerant system, overview Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

Condensing Boiler Efficiency

Condensing Boiler Efficiency Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2

More information

VRF CATALOGUE HEAT PUMP & HEAT RECOVERY. for Europe. Variable Refrigerant Flow System

VRF CATALOGUE HEAT PUMP & HEAT RECOVERY. for Europe. Variable Refrigerant Flow System VRF Variable Refrigerant Flow System CATALOGUE HEAT PUMP & HEAT RECOVERY for Europe Fujitsu General have been developing and manufacturing high quality and energy efficient products for more than 35 years.

More information

HDA -----------------------------------------------------------

HDA ----------------------------------------------------------- ----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS

More information

Aerona Air Source Heat Pumps

Aerona Air Source Heat Pumps ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of

More information

Air Conditioning for Small and Medium-size Buildings

Air Conditioning for Small and Medium-size Buildings Air Conditioning for Small and Medium-size Buildings Defining a HIGHER standard The all-new MiNi-SMMS air conditioner lineup lets you cool or warm as many as 12 *1 rooms with a single system. Outdoor units

More information

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS POER, FLEXIBILITY, RESIDENTIAL Carrier presents the new line of multi-split systems A complete and flexible range designed to meet every residential and light

More information

LG Air Conditioning Solutions COMFORT MADE EASY. COMFORT MADE BEAUTIFUL.

LG Air Conditioning Solutions COMFORT MADE EASY. COMFORT MADE BEAUTIFUL. Residential Brochure LG Air Conditioning Solutions COMFORT MADE EASY. COMFORT MADE BEAUTIFUL. LG DUCT-FREE Split SYSTEMS BRING COMFORTING INNOVATION LG Duct-Free Split systems allow you to cool or heat

More information

Saving energy by solar collector and heat pump combination in hot water production in residential and hotel sectors

Saving energy by solar collector and heat pump combination in hot water production in residential and hotel sectors Saving energy by solar collector and heat pump combination in hot water production in residential and hotel sectors Dr. Nguyen Nguyen An, HUST CONTENTS Energy consumption to produce hot water in residential

More information