TECHNICAL REQUIREMENTS OF ISO/IEC 17025:2005
|
|
- Godwin Cooper
- 7 years ago
- Views:
Transcription
1 SADCAS Ref. No: TECHNICAL REQUIREMENTS OF ISO/IEC 17025:2005 Date/s of Evaluation: Assessor/s & Observers: Laboratory: Area / Field of Operation: Laboratory Representative: This report covers the following: Document Review only Implementation on Site Visit only Document Review And Site Visit Other Clause REQUIREMENTS & COMMENTS Compliance = C, Non-Compliance = NC, Not Applicable = NA Comment below on adequacy of how requirements have been addressed, documented and/or implemented. References to ISO/IEC are in italics & indicated as Std. The order of assessment need not follow the order of the checklist. Assessors are expected to know & have the standard, this worksheet is designed as guidance to prompt detailed recording of the process. REFER TO ISO/IEC FOR DETAIL AND FOR CLARIFICATION NOTES. 5 TECHNICAL REQUIREMENTS 5.1 General: Factors determining correctness, reliability of tests/calibrations performed Extent to which factors contributing to total uncertainty of measurement taken into account in: developing methods/procedures; training, qualification of staff; selection, calibration of equipment. C NC NA 5.2 Personnel: How are the following addressed/ implemented? Note Std Competence of all who operate specific equipment, perform tests/calibrations, evaluate results, sign reports/ certificates. Qualified on basis of appropriate education, training, experience and/or demonstrated skills. Appropriate supervision of trainees Goals education, training, skills. ID training needs, provide training. Evaluate effectiveness of training. Programme relevant to tasks Employed by/under contract. Supervised, competent, work in accordance with lab s management system Current job descriptions for managerial, technical, key support personnel involved in Note Std tests/calibrations Authorize specific personnel to: perform particular types of sampling, test, calibration; issue reports certificates; give opinions, interpretations; operate particular types of equipment. Records of authorization(s), competence, educational, professional qualifications, training, skills, experience of all technical personnel, including contracted personnel. Date, readily available. Issue No.: 1 Page 1 of 12 Date of Issue:
2 Additional / General Comments (This space may also be used to expand on comments in specific sections) 5.3 Accommodation and Environmental Conditions: How are the following addressed/ implemented? Issue No.: 1 Page 2 of 12 Date of Issue:
3 5.3.1 Not invalidate/adversely affect results. Permanent lab/other sites. Requirements documented Monitor, control, record where quality of results influenced. Stop work when results jeopardized Effective separations between incompatible activities. Measures to prevent cross contamination Access to areas affecting quality of tests/calibrations controlled based on particular circumstances Measures taken to ensure good housekeeping. Special procedures prepared where necessary. 5.4 Test &Calibration Methods &Method validation: How are the following addressed/ implemented? General: Appropriate for scope. Include sampling, handling, transport, storage, preparation, Note Std use/operation of equipment. Estimation of measurement uncertainty & statistic techniques for & See analysis of data, where their absence could jeopardize results. Up-to-date and readily available. 4.3 Deviations documented, technically justified, authorized, accepted by customer Selection of methods: How are the following addressed/ implemented? Meet needs of customer, appropriate for tests/calibrations. Prefer international, regional, national standards. Latest valid edition. Supplements to ensure consistency. By reputable technical organizations/in relevant scientific texts/journals or specified by the manufacturer of the equipment. Laboratory developed method/s appropriate for intended use and validated. Customer informed as to the method chosen. Confirm that it can properly operate standard methods before introducing the tests/calibrations. Confirmation repeated if standard method changes. Customer informed when method proposed by customer is considered to be inappropriate or out of date Laboratory developed methods: How are the following addressed/ implemented? Note Std Introduction of method planned, assigned to qualified persons equipped with adequate resources. Plans up-dated as development proceeds, effective communication amongst all persons involved. Non-standard methods: How are the following addressed/ implemented? Agreement with the customer, include clear specification of the customer s requirements and the purpose of the test and/or calibration. Validated appropriately before use Notes Std Notes Std Validation of methods: Confirmation by examination and provision of objective evidence that particular requirements for specific intended uses are fulfilled. Validate non-standard methods; laboratory-developed methods; standard methods used outside intended scope; amplifications/modifications of standard methods. As extensive as is necessary for application/field of application. Record results, procedure, statement of fitness for intended use. Range and accuracy as assessed for the intended use relevant to the customers needs. e.g. the uncertainty, detection limit, selectivity, linearity, repeatability, reproducibility, robustness) Issue No.: 1 Page 3 of 12 Date of Issue:
4 Additional / General Comments (This space may also be used to expand on comments in specific sections) Issue No.: 1 Page 4 of 12 Date of Issue:
5 5.4.6 Estimation of Uncertainty of Measurement: How are the following addressed/ implemented? Test &Calibration labs; uncertainty procedure for all calibrations and types of calibrations NB Notes std Notes Std Testing laboratories, identification of all the components of uncertainty & reasonable estimation is attempted. Reporting of results do not give wrong impression of uncertainty. Estimation based on knowledge of performance of method, measurement scope and validation data. All uncertainty components of importance in the given situation taken into account using appropriate methods of analysis Control of data: How are the following addressed/ implemented? Calculations and data transfers subject to appropriate checks in a systematic manner. (e.g. Scientific notation & rounding-off policy) Electronic equipment for acquisition, processing, recording, reporting, storage or retrieval of data. a) Software developed by user documented in sufficient detail, suitably validated as adequate for use. b) Procedures for integrity & confidentiality of data entry, collection, storage, transmission, processing. c) Notes Std Computers/automated equipment, proper functioning, conditions to maintain the integrity of data. 5.5 Equipment: How are the following addressed/ implemented? All required equipment & its software, including that outside its permanent control available Capable of achieving accuracy required, comply with relevant specifications. Calibration programmes See 5.6 for key quantities having significant effect on results. Calibrated/checked before use Operated by authorized personnel. Up-to-date instructions use, maintenance readily available Each item significant to the result, when practicable, uniquely identified Records maintained of each item significant to the tests and/or calibrations performed. a) The identity of the item of equipment and its software. b) The manufacture s name, type identification and serial number or other unique identification. c) Checks that equipment complies with the specification (see 5.5.2) d) The current location, where appropriate. e) The manufacturers instructions, if available, or reference to their location. f) Dates, results, reports/certificates, adjustments, acceptance criteria, due date of next calibration. g) The maintenance plan, where appropriate and maintenance carried out to date. h) Any damage, malfunction, modification or repair to the equipment. Issue No.: 1 Page 5 of 12 Date of Issue:
6 5.5.6 Notes Std Procedures for safe handling, transport, storage, use and planned maintenance of measuring equipment to ensure proper functioning and in order to prevent contamination or deterioration Defective equipment, prevented from use until shown by calibration or test to perform correctly. See 4.9 Examine effect of defect on previous tests/calibrations, control non-conforming work procedure When practicable identified to indicate calibration status, date last calibrated, re-calibration due Outside direct control, ensure function & calibration checked, satisfactory before returned to use Intermediate checks to maintain confidence in calibration status carried out to defined procedure Calibrations correction factors, procedures to ensure copies (e.g. in software) are correctly updated Equipment, hardware and software, safeguarded from adjustments, which would invalidate results. Additional / General Comments (This space may also be used to expand on comments in specific sections) Issue No.: 1 Page 6 of 12 Date of Issue:
7 5.6 Measurement Traceability: How are the following addressed/ implemented? Note Std General: All equipment including for subsidiary measurements having a significant effect on validity of results, calibrated before being put into service. Established programme and procedure for the calibration of its equipment Specific requirements Calibration: How are the following addressed/ implemented? Calibration laboratories, programme to ensure traceability to International System of Units (SI). Notes Std Stds & instruments to SI by unbroken chain of comparisons link to primary standards. See also Use laboratories demonstrating competence, measurement capability and traceability Certificates contain results, uncertainty/statement of compliance with identified metrological spec Calibration providing confidence in measurement by establishing traceability to standards such as: Certified reference materials provided by a competent supplier. Specified methods and/or consensus standards that are clearly described, agreed by all parties. Participation in a suitable programme of inter-laboratory comparisons where possible Testing: How are the following addressed/ implemented? Measuring & test equipment with measuring functions apply , unless calibration contributes Note Std little to total uncertainty of test result. Equipment providing uncertainty of measurement needed SI not possible, then certified reference materials, agreed methods, consensus standards, Reference standards and reference materials: How are the following addressed/ implemented? Reference standards: Programme & procedure for calibration, traceable. Used for calibration only unless not validated. Calibrated before and after any adjustment Reference materials: Traceable to SI units/to certified reference materials. Internal checked Intermediate checks: Checks to maintain confidence in calibration status of reference, primary, transfer/working standards, reference materials according to defined procedures and schedules Transport and storage: Procedures for safe handling, transport, storage and use in order to Note Std prevent contamination or deterioration and to protect their integrity. Issue No.: 1 Page 7 of 12 Date of Issue:
8 5.7 Sampling: How are the following addressed/ implemented? Notes Std Sampling plan & procedures available at the location where sampling is undertaken. Based on appropriate statistical methods, address factors to control to ensure validity of results Customer required deviations, recorded in detail with sampling data, results, communicated to all staff Records of data & operations, procedure, sampler, environmental conditions, location, statistics 5.8 Handling of test and calibration items: How are the following addressed/ implemented? Transport, receipt, handling, protection, storage, retention, disposal, protect integrity/interests Identify, for life of item, not confuse, accommodate sub-division and transfer of items Departures recorded on receipt. Where doubt consult customer before proceeding and record Notes Std Avoid deterioration, loss /damage storage, handling, preparation. Follow instruction. Environmental conditions maintained, monitored, recorded. Storage secure, protect condition and integrity. Additional / General Comments (This space may also be used to expand on comments in specific sections) Issue No.: 1 Page 8 of 12 Date of Issue:
9 5.9 Assuring the quality of test & calibration results: How are the following addressed/ implemented? QC procedures to monitor validity of results, data recorded, trends, statistics. Planned & reviewed: Note Std a) Regular use of certified reference materials and/or secondary reference materials. b) Participation in inter-laboratory comparison or proficiency testing programmes. c) Replicate tests or calibrations using the same or different methods. d) Re-testing or re-calibration of retained items. e) Correlation of results for different characteristics of an item QC data analysis. Action plan for incorrect results. Preventing the reporting of incorrect results. Issue No.: 1 Page 9 of 12 Date of Issue:
10 5.10 Reporting the results: How are the following addressed/ implemented? Notes Std Notes Std General Accurate, clear, unambiguous, objective, in accordance with specific instructions in methods. Information requested by client & for interpretation of results, refer and or Internal customers/written agreement, report simplified. Information 5,10.2 to readily available. Test reports and calibration certificates: How are the following addressed/ implemented? Report/certificate include at least following information unless the laboratory has valid reasons: a) A title (e.g. Test Report or Calibration Certificate ). b) Name and address of the laboratory and location of work, if different from address of laboratory c) Unique identification of report/certificate, on each page, clear identification of end. d) The name and address of the customer. e) Identification of the method used. f) Description of, the condition of, and unambiguous identification of the item(s) tested or calibrated. g) Date of receipt of item(s) where critical to validity and application of results, date(s) of performance. h) Reference to sampling plan and procedures used where relevant to validity or application of results. i) The test or calibration results with, where appropriate, the units of measurement. j) Name/s, function/s, signature/s or equivalent identification of person/s authorizing report certificate. k) Where relevant, a statement to the effect that the results relate only to the items tested/calibrated Tests reports In addition to , for test reports, where necessary for interpretation of test results, include; a) Deviations, additions, exclusions from test method, specific test conditions, such as environmental b) Where relevant, a statement of compliance/non compliance with requirements/specifications c) Estimated uncertainty of measurement; need when: -relevant to validity or application of results, -a customer requirement, -uncertainty affects compliance to specification limit d) Where appropriate and needed, opinions and interpretations (see ) e) Additional information, required by specific methods, customers or groups of customers In addition to and , results include the following, for interpretation of results: a) The date of sampling b) Unambiguous identification, manufacturer s name, model or type of designation, serial numbers c) The location of sampling, including any diagrams, sketches or photographs. d) A reference to the sampling plan and procedures used e) Environmental conditions during sampling that may affect the interpretation of the test results. f) Standard/other specification for sampling methods, deviations, additions, exclusions. Issue No.: 1 Page 10 of 12 Date of Issue:
11 Additional / General Comments (This space may also be used to expand on comments in specific sections) Issue No.: 1 Page 11 of 12 Date of Issue:
12 Calibration certificates In addition to , do certificates include the following, for interpretation of calibration results: a) Conditions (e.g. environmental) that have an influence on the measurement results. b) Measurement uncertainty/statement of compliance with metrological specification/clauses thereof. c) Evidence that the measurements are traceable? (see note 2 in ) Relate only to quantities and the results of functional tests. Statement of compliance with specification, identify which clauses of specification are met/not met Compliance statement omitting results & uncertainties, record maintain results for future reference Statements of compliance made, the uncertainty of measurement taken into account Adjusted or repaired, calibration results before and after adjustment/repair, if available, reported Not recommend calibration intervals unless agreed with customer, superseded by legal regulations Opinions and interpretations: Document basis upon which they have been made. Clearly marked Notes Std as such in a test report Testing and calibration results obtained from subcontractors Test results clearly identified. The sub-contractor reports the results in writing or electronically. Calibration laboratory performing work issues the calibration certificate to contracting laboratory Electronic transmission of results: Requirements of this international standard met (see also 5.4.7) Format of reports and certificates: Designed to accommodate each type of test or calibration Notes Std carried out and to minimize the possibility of misunderstanding or misuse Amendments to test reports & calibration certificates: Further document/data transfer include Supplement to Test Report/Calibration Certificate, identification, / equivalent form of wording Meet all the requirements of this international standard When complete new report/certificate, uniquely identified, contain reference to original replaced. General/additional comments and matters to follow up at next assessment Signed Lead/Technical Assessor: Date: Issue No.: 1 Page 12 of 12 Date of Issue:
Quality Management System Policy Manual
Quality Management System Burns Engineering, Inc. 10201 Bren Road East Minnetonka, MN 55343 4. 4.1 General Requirements The Quality Manual consists of the quality system policy documents and the quality
More informationISO/IEC 17025 QUALITY MANUAL
1800 NW 169 th Pl, Beaverton, OR 97006 Revision F Date: 9/18/06 PAGE 1 OF 18 TABLE OF CONTENTS Quality Manual Section Applicable ISO/IEC 17025:2005 clause(s) Page Quality Policy 4.2.2 3 Introduction 4
More informationNIST HANDBOOK 150 CHECKLIST
NIST HANDBOOK 150 CHECKLIST Instructions to the Assessor: This checklist addresses the general accreditation criteria prescribed in NIST Handbook 150, NVLAP Procedures and General Requirements (2006 edition).
More informationState Meat and Poultry Inspection (MPI) Program Laboratory Quality Management System Checklist
This checklist is intended to help laboratories improve the quality of their testing programs with regard to meat and poultry testing samples, in order to ensure those laboratories are at least equal to
More informationQuality Assurance Manual January 2008 Revision I Revision date of 01/17/13. Pi Tape Corporation. 344 North Vinewood St. Escondido CA 92029-1337 USA
Quality Assurance Manual January 2008 Revision I Revision date of 01/17/13 Pi Tape Corporation 344 North Vinewood St. Escondido CA 92029-1337 USA Phone # 760 746-9830 Fax # 760 746-9196 In conformance
More informationOD-2017-Ed.1.5 CHECK LIST FOR TESTING AND CALIBRATION LABORATORIES
IECEE OD-2017-Ed.1.5 OPERATIONAL & RULING DOCUMENTS CHECK LIST FOR TESTING AND CALIBRATION LABORATORIES Rev 2006-09-22 OD-2017-Ed.1.5 IEC - IECEE 2007 - Copyright all rights reserved Except for IECEE members
More informationOMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (06) 72 2R (FORM/158-Rev.02) STANDARD AIDE-MEMOIRE FOR THE MJA/MJV OF OMCLs Full document title and reference Document type
More informationProcedure for Equipment Calibration and Maintenance
Procedure for Equipment Calibration and Maintenance 1.0 Purpose This procedure specifies the schedule and requirements for calibration, performance verification, and maintenance of State Crime Laboratory
More informationChecklist. Standard for Medical Laboratory
Checklist Standard for Medical Laboratory Name of hospital..name of Laboratory..... Name. Position / Title...... DD/MM/YY.Revision... 1. Organization and Management 1. Laboratory shall have the organizational
More informationLuminus Devices, Inc Luminus Testing Laboratory Quality Management Systems Manual
Luminus Devices, Inc Luminus Testing Laboratory Quality Management Systems Manual ISO/IEC 17025 NVLAP, NIST HANDBOOKS 150,150-1 This document belongs to Luminus Devices, Inc. It cannot be reproduced without
More informationTITLE: Quality System Manual DOCUMENT NUMBER: QMS
1 of 19 BUSINESS PROCESS (BP) QUALITY MANAGEMENT SYS NAME SIGNATURE DATE PREPARED BY BILL ATKINSON SIGNATURE ON FILE 12/3/2014 APPROVALS DEPARTMENT NAME SIGNATURE DATE PRESIDENT DANNY ANGEL SIGNATURE ON
More informationTesting Facility Laboratory Manual
Quality Synthetic Rubber's Testing Facility Laboratory Manual Quality Synthetic Rubber, Inc. 1700 Highland Road P.O. Box 1030 Twinsburg, Ohio 44087-9030 Phone: 330-425-8472 Duns Code: 01-753-2458 Z-Code:
More informationInternal Quality Management System Audit Checklist (ISO9001:2015) Q# ISO 9001:2015 Clause Audit Question Audit Evidence 4 Context of the Organization
Internal Quality Management System Audit Checklist (ISO9001:2015) Q# ISO 9001:2015 Clause Audit Question Audit Evidence 4 Context of the Organization 4.1 Understanding the organization and its context
More informationNABL NATIONAL ACCREDITATION
NABL 160 NABL NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES GUIDE for PREPARING A QUALITY MANUAL ISSUE NO. : 05 AMENDMENT NO : 00 ISSUE DATE: 27.06.2012 AMENDMENT DATE: -- Amendment
More informationGap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing
Gap Analysis May 2013 Issued: May 2013 Gap Analysis of and in the field of Medical Testing Copyright National Association of Testing Authorities, Australia 2013 This publication is protected by copyright
More informationSurgi Manufacturing Quality Manual
Surgi Manufacturing Page 1 of 18 Approvals: QA: Eng. Mgt. : A Date: 18Aug98 1. Introduction... 4 1.1 Scope... 4 1.2 Purpose... 4 1.3 Authority... 4 1.4 Issue of the Manual... 4 1.5 Amendments... 4 1.6
More informationISO 9001:2015 Internal Audit Checklist
Page 1 of 14 Client: Date: Client ID: Auditor Audit Report Key - SAT: Satisfactory; OBS: Observation; NC: Nonconformance; N/A: Not Applicable at this time Clause Requirement Comply Auditor Notes / Evidence
More informationISO 9001:2000 Gap Analysis Checklist
ISO 9001:2000 Gap Analysis Checklist Type: Assessor: ISO 9001 REQUIREMENTS STATUS ACTION/COMMENTS 4 Quality Management System 4.1 General Requirements Processes needed for the quality management system
More informationISO 17025 and SANAS guidelines for use of reference materials and PT scheme participation Shadrack Phophi
ISO 17025 and SANAS guidelines for use of reference materials and PT scheme participation Shadrack Phophi The Innovation Hub, Pretoria Presentation layout 1. Introduction ISO/IEC 17025 2. Requirements
More informationSTANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION
Directive from the Scientific Director Page 1 of 16 STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION 1 Scope To describe the procedure for breath alcohol instrument calibration
More informationISO 9001:2000 AUDIT CHECKLIST
ISO 9001:2000 AUDIT CHECKLIST No. Question Proc. Ref. Comments 4 Quality Management System 4.1 General Requirements 1 Has the organization established, documented, implemented and maintained a quality
More informationCRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES
CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES Prepared by: Technical Manager Approved by: Chief Executive Officer Approval Date: 2013-04-24 Effective
More informationAmerican Association for Laboratory Accreditation
Page 1 of 15 R104 GENERAL REQUIREMENTS: ACCREDITATION OF FIELD TESTING AND FIELD CALIBRATION LABORATORIES July 2015 2015 by A2LA All rights reserved. No part of this document may be reproduced in any form
More informationREQUIREMENTS FOR AN ACCREDITED VETERINARY MEDICAL DIAGNOSTIC LABORATORY
REQUIREMENTS FOR AN ACCREDITED VETERINARY MEDICAL DIAGNOSTIC LABORATORY AMERICAN ASSOCIATION OF VETERINARY LABORATORY DIAGNOSTICIANS, INC. Version 6.1 AC-201, Version 6.1, 06-01-12 Page 1 of 27 Table of
More informationNon-Controlled Copy. Quality Manual Revision Log. Rev # Date Description
Quality Manual Revision Log Rev # Date Description 1 Oct 1984 Original Document. 2 Aug 1986 Document Hillsboro Move. Complete Revision. 3 May 1988 Incorporate/Beaverton Move. Reformat to Word Perfect 4.0.
More informationDNV GL Assessment Checklist ISO 9001:2015
DNV GL Assessment Checklist ISO 9001:2015 Rev 0 - December 2015 4 Context of the Organization No. Question Proc. Ref. Comments 4.1 Understanding the Organization and its context 1 Has the organization
More informationOH&S MANAGEMENT SYSTEM CHECKLIST - AS 4801:2001 (STATUS A = Acceptable; N = Not Acceptable; N/A = Not Applicable)
OH&S MANAGEMENT SYSTEM CHECKLIST - AS 4801:2001 (STATUS A = Acceptable; N = Not Acceptable; N/A = Not Applicable) 4.1 General Requirements 4.2 OHS policy Has the organisation an established and maintained
More informationISO 9001 (2000) QUALITY MANAGEMENT SYSTEM ASSESSMENT REPORT SUPPLIER/ SUBCONTRACTOR
Page 1 of 20 ISO 9001 (2000) QUALITY MANAGEMENT SYSTEM ASSESSMENT REPORT SUPPLIER/ SUBCONTRACTOR SUPPLIER/ SUBCONTRACTOR NAME: ADDRESS: CITY AND STATE: ZIP CODE: SUPPLIER/MANUFACTURER NO PHONE: DIVISION:
More informationCALIBRATION DATA MANAGEMENT: MEETING THE REPORTING REQUIREMENTS OF ISO/IEC FDIS 17025.
CALIBRATION DATA MANAGEMENT: MEETING THE REPORTING REQUIREMENTS OF ISO/IEC FDIS 17025. Nicholas Mason Metrology Software Project Manager Calibration Group, Fluke Corporation 6920 Seaway Blvd. Everett,
More informationEA IAF/ILAC Guidance. on the Application of ISO/IEC 17020:1998
Publication Reference EA IAF/ILAC-A4: 2004 EA IAF/ILAC Guidance on the Application of ISO/IEC 17020:1998 PURPOSE This guidance document is for ISO/IEC 17020: General Criteria for the operation of various
More informationSouth Coast Air Quality Management District
South Coast Air Quality Management District Laboratory Approval Program Administrative, Operational and Technical Requirements November 2015 Direct Inquiries to: Laboratory Approval Program Coordinator
More informationNABL accreditation is a formal recognition of the technical competence of a medical testing laboratory
NABL accreditation is a formal recognition of the technical competence of a medical testing laboratory Third party assessment NABL has Mutual Recognition Arrangement with APLAC and ILAC NABL accredited
More informationCHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems
Date(s) of Evaluation: CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems Assessor(s) & Observer(s): Organization: Area/Field
More informationEDUCATION AND TRAINING OF THE LABORATORY STAFF AS A PART OF THE LABORATORY COMPETENCE
The First International Proficiency Testing Conference Sinaia, România 11 th 13 th October, 2007 EDUCATION AND TRAINING OF THE LABORATORY STAFF AS A PART OF THE LABORATORY COMPETENCE Olga Štajdohar-Pađen
More informationGENERAL WELDING & FABRICATING, INC. 991 Maple Road Elma, New York 14059
QUALITY MANUAL GENERAL WELDING & FABRICATING, INC. 991 Maple Road Elma, New York 14059 Distribution: Position Location Copy # President / CEO Office 1 Operations Manager Office 2 Quality Assurance Office
More informationProduct Liability Risk Control Checklist
Product Liability Risk Control Checklist Appendix C1 This material will help you evaluate your products liability exposure. It is designed to enable you to focus on areas that need to be addressed to safeguard
More informationISO 9001:2008 Audit Checklist
g GE Power & Water ISO 9001:2008 Audit Checklist Organization Auditor Date Page 1 Std. 4.1 General s a. Are processes identified b. Sequence & interaction of processes determined? c. Criteria for operation
More informationIAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS
REFERENCES NIST Special Publication 330 IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS Revised October 2013 International vocabulary of metrology Basic and general concepts and
More informationGLOBAL AEROSPACE PROCEDURE
1 of 13 1. PURPOSE: This procedure establishes the minimum PPG Aerospace requirements for a Supplier's Quality Plan. These requirements pertain to the documentation and inspection/testing necessary to
More informationGood Research Practice
Page 1 of 8 The Royal Veterinary College Introduction Preface Good Research Practice Funding bodies need to be assured of the quality and validity of research they fund and ensure their contractors are
More informationRecognition of my Product (Testing Laboratory) Why I need recognition, what is the effect?
Page 1 of 23 Accreditation of Testing Laboratories Accreditation of (Sports Surface) Testing Laboratories Konrad Binder (OIST / Austria) ISSS Year 2000 Forum (Schaffhausen) Note: This is a summary of the
More informationSection i POLICY AND AUTHORITY STATEMENT
Section i POLICY AND AUTHORITY STATEMENT It is the policy of Laboratory Testing, Incorporated (LTI)*, as a Material Organization, to furnish and perform testing services in nondestructive, mechanical,
More informationBLOOM AND WAKE (ELECTRICAL CONTRACTORS) LIMITED QUALITY ASSURANCE MANUAL
130 Wisbech Road Outwell Wisbech Cambridgeshire PE14 8PF Tel: (01945) 772578 Fax: (01945) 773135 Copyright 2003. This Manual and the information contained herein are the property Bloom & Wake (Electrical
More informationNIST HANDBOOK 150-5 CHECKLIST CONSTRUCTION MATERIALS TESTING
NIST HANDBOOK 150-5 CHECKLIST CONSTRUCTION MATERIALS TESTING Instructions to the Assessor: This checklist addresses specific accreditation criteria prescribed in NIST Handbook 150-5, Construction Materials
More informationPROPOSED UPDATED TEXT FOR WHO GOOD MANUFACTURING PRACTICES FOR PHARMACEUTICAL PRODUCTS: MAIN PRINCIPLES (JANUARY 2013)
January 2013 RESTRICTED PROPOSED UPDATED TEXT FOR WHO GOOD MANUFACTURING PRACTICES FOR PHARMACEUTICAL PRODUCTS: MAIN PRINCIPLES (JANUARY 2013) DRAFT FOR COMMENTS Please address any comments on this proposal
More informationDEC STD 017-2 - ISO 9002 - Quality Systems - Model for Quality Assurance in Production and Installation
Digital Internal Use Only DEC STD 017-2 - ISO 9002 - Quality Systems - Model for Quality Assurance in Production and Installation DOCUMENT IDENTIFIER: A-DS-EL00017-02-0000 Rev A, ABSTRACT: This standard
More informationMeasuring equipment in a laboratory.
Measuring equipment in a laboratory. Laboratory and metrology are two words that practically do not function separately. They are integrally connected to measuring equipment for tests and measurements.
More informationSoftware Verification and Validation
Software Verification and Validation Georgia L. Harris Carol Hockert NIST Office of Weights and Measures 1 Learning Objectives After this session, using resources and references provided, you will be able
More informationTHERMAL INSULATION MATERIALS
NIST HANDBOOK 150-15 2006 Edition National Voluntary Laboratory Accreditation Program THERMAL INSULATION MATERIALS Lawrence I. Knab National Voluntary Laboratory Accreditation Program Standards Services
More informationCompany Quality Manual Document No. QM Rev 0. 0 John Rickey Initial Release. Controlled Copy Stamp. authorized signature
Far West Technology, Inc. ISO 9001 Quality Manual Document No.: QM Revision: 0 Issue Date: 27 August 1997 Approval Signatures President/CEO Executive Vice President Vice President/CFO Change Record Rev
More informationRULES FOR THE PARTICIPATION IN INTER- LABORATORY COMPARISONS AND PROFICIENCY TESTING SCHEMES
RULES FOR THE PARTICIPATION IN INTER- LABORATORY COMPARISONS AND PROFICIENCY TESTING SCHEMES Reviewed by: Natalija Jovičić Zarić MSc, Quality Manager Approved by: Milica Lukešević, Acting Director Any
More informationISO/IEC 17020 Inspection Standard Application Document
ISO/IEC 17020 Inspection Standard Application Document August 2015 Copyright National Association of Testing Authorities, Australia 2015 This publication is protected by copyright under the Commonwealth
More informationCOMPANY NAME. Environmental Management System Manual
Revision No. : 1 Date : DD MM YYYY Prepared by : Approved by : (EMR) (Top Management) Revision History Revision Date Description Sections Affected Revised By Approved By Table of Content 0.0 Terms and
More informationISO 9001:2008 Quality Management System Requirements (Third Revision)
ISO 9001:2008 Quality Management System Requirements (Third Revision) Contents Page 1 Scope 1 1.1 General. 1 1.2 Application.. 1 2 Normative references.. 1 3 Terms and definitions. 1 4 Quality management
More informationEffiValidation 3.0 software basic training module
EffiValidation 3.0 software basic training module Oct 3, 2012 www.effichem.com Agenda EffiChem company EffiValidation 3.0 software : overview International standards and guidelines Software features Structure
More informationMeasuring instruments in industry.
Measuring instruments in industry. Measuring instruments that are present in any branch of industry, are subject to different levels of supervision, like in case of laboratories. Supervision relates to
More informationISO-9001:2000 Quality Management Systems
ISO-9001:2000 Quality Management Systems REQUIREMENTS 10/10/2003 ISO-9001:2000 Requirements 1 Process Based Approach C U S MANAGEMENT RESPONSIBILITY RESOURCE MANAGEMENT C U S T O M Requirements PRODUCT
More informationCOMMISSION DIRECTIVE 2003/94/EC
L 262/22 COMMISSION DIRECTIVE 2003/94/EC of 8 October 2003 laying down the principles and guidelines of good manufacturing practice in respect of medicinal products for human use and investigational medicinal
More informationCORPORATE QUALITY MANUAL
Corporate Quality Manual Preface The following Corporate Quality Manual is written within the framework of ISO 9001:2008 Quality System by the employees of CyberOptics. CyberOptics recognizes the importance
More informationUNCONTROLLED COPY FOR REFERENCE ONLY
CLOVER MACHINE AND MFG. 800 MATHEW ST. #101 SANTA CLARA, CA 95050 727-3380 727-7015 fax REVISION: DATE: PAGE 1 OF 45 QUALITY POLICY MANUAL DISTRIBUTION LIST: President Purchasing Manager Vice President
More informationISO 9001: 2008 Boosting quality to differentiate yourself from the competition. xxxx November 2008
ISO 9001: 2008 Boosting quality to differentiate yourself from the competition xxxx November 2008 ISO 9001 - Periodic Review ISO 9001:2008 Periodic Review ISO 9001, like all standards is subject to periodic
More informationRow Manufacturing Inc. Quality Manual ISO 9001:2008
Row Manufacturing Inc. Quality Manual ISO 9001:2008 Row Manufacturing 210 Durham Drive Athens, Alabama 35611 Phone:256.232.4151 Fax:256.232.4133 Page 2 of 33 This Page intentionally left Blank Page 3 of
More informationQUALITY MANUAL ISO 9001:2015
Page 1 of 22 QUALITY MANUAL ISO 9001:2015 Quality Management System Page 1 of 22 Page 2 of 22 Sean Duclos Owner Revision History Date Change Notice Change Description 11/02/2015 1001 Original Release to
More informationSupplier Quality Management System Audit Checklist (ISO 9000:2000, TS 16949:2002)
Supplier Quality Management System Audit Checklist (ISO 9000:2000, TS 16949:2002) Supplier: Plant/Location: Date: Audit Team: Scope of Audit: Number of C.A.R. s: Corrective Action Due: Potential suppliers
More informationRTP s NUCLEAR QUALITY ASSURANCE PROGRAM
RTP s NUCLEAR QUALITY ASSURANCE PROGRAM RTP operates under one quality program, whether you purchase products that are commercial grade, nuclear safety-related or industrial safety compliant (IEC 61508).
More informationOPERATIONAL STANDARD
1 of 11 1. Introduction The International Safe Transit Association (ISTA), a non-profit association whose objective is to prevent product damage and excess packaging usage within the distribution environment.
More informationGeneric CMMS Quality Assurance Plan
Generic CMMS Quality Assurance Plan Scope In accordance with the Quality Policy, the Quality System of CMMS is based upon the requirements and structure of ISO (the International Organization for Standardization)
More informationLAB ID and/or LABORATORY NAME: ASSESSOR NAME: CONTINUOUS RADON MONITOR (CRM) by Proportional Counting. Method Number: ELAP method code 7037
LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: CONTINUOUS RADON MONITOR (CRM) by Proportional Counting Method Number: ELAP method code 7037 SOP Number: Revision Number: SOP Date: Personnel / Data
More informationUS EPA REGION III QUALITY MANAGEMENT PLAN REVIEW CHECKLIST
US EPA REGION III Organization: EPA Organization: EPA Program: Contact: EPA Contact: EPA Contract/Grant/IAG Number: Phone Number: Phone Number: Reviewer: Date Reviewed: Reviewer Organization: Check New
More informationEagle Machining, Inc. Quality Management System
Eagle Machining, Inc. Quality Management System 1 of 10310 Antoine Drive Bldg D, Houston, Texas 77086 BUSINESS OPERATING MANUAL (QUALITY MANUAL) Revision Date: 08/01/2014 Approved By: Joseph Vu Date: 08/01/2014
More informationCCD MARINE LTD QUALITY MANUAL PROCEDURE Q0.000. Date: Title. Revision: QUALITY MANUAL PROCEDURE Q0.000. 29 September 2014
Title: Quality Manual Uncontrolled if Hardcopy CCD MARINE LTD th Date: 29 September 2014 Doc Ref: Q0.000 Issued By: Sarah Leighton Rev No: 2 Title Revision: Date: QUALITY MANUAL PROCEDURE Q0.000 2 29 September
More informationISO 9001 : 2008 QUALITY MANAGEMENT SYSTEM AUDIT CHECK LIST INTRODUCTION
INTRODUCTION What auditors should look for: the items listed in these headings that the ISO requirement is met that the requirement is met in the manner described in the organization's documentation Page
More informationA Guide for Documenting the Management System for a Testing/Calibration Lab. May 2015
A Guide for Documenting the Management System for a Testing/Calibration Lab May 2015 1. Introduction The following guide is to help testing/calibration laboratories create documentation to satisfy the
More informationQUALITY MANUAL GREAT LAKES INSTITUTE FOR ENVIRONMENTAL RESEARCH ANALYTICAL LABORATORIES. October 2008 Revision 08
QUALITY MANUAL GREAT LAKES INSTITUTE FOR ENVIRONMENTAL RESEARCH ANALYTICAL LABORATORIES October 2008 Revision 08 Great Lakes Institute for Environmental Research University of Windsor Windsor, Ontario
More informationFMC Technologies Measurement Solutions Inc.
Table of Contents 1 Revision History... 4 2 Company... 5 2.1 Introduction... 5 2.2 Quality Policy... 6 2.3 Quality Organization... 6 2.4 Company Processes... 7 3 Scope and Exclusions... 8 3.1 Scope...
More informationValidation and Calibration. Definitions and Terminology
Validation and Calibration Definitions and Terminology ACCEPTANCE CRITERIA: The specifications and acceptance/rejection criteria, such as acceptable quality level and unacceptable quality level, with an
More informationNC SBI QUALITY ASSURANCE PROGRAM
NC SBI QUALITY ASSURANCE PROGRAM for the SBI Reviewed by: Deputy Assistant Director Bill Weis Date: Approved by: Assistant Director Jerry Richardson Date: Originating Unit: SBI Effective Date: July 25,
More informationCQR-1 CONTRACTOR QUALITY REQUIREMENTS for CONSTRUCTION SERVICES
1.0 SCOPE CQR-1 CONTRACTOR QUALITY REQUIREMENTS for CONSTRUCTION SERVICES This document establishes the minimum quality program requirements for a contractor providing equipment, material, and construction
More informationUL Qualified Firestop Contractor Program Requirements April 2012
UL Qualified Firestop Contractor Program Requirements April 2012 For more information, please contact your local UL Field Representative INTRODUCTION: In order for a firestop systems installer/contractor
More informationP07 CALA Application of Requirements in ISO/IEC 17025:2005 Revision 3.4 April 9, 2014
P07 CALA Application of Requirements in ISO/IEC 17025:2005 Revision 3.4 April 9, 2014 1 TABLE OF CONTENTS FOREWORD... 1 1.0 SCOPE... 1 1.5 Safety Requirements... 1 4.0 MANAGEMENT REQUIREMENTS... 1 4.1
More informationPRODUCT CERTIFICATION REQUIREMENTS
PRODUCT CERTIFICATION REQUIREMENTS SIRIM QAS International Product Certification Page 1 of 14 QUALITY SYSTEM 1. GENERAL 1.1 This document defines the responsibilities and obligations of the Licensee with
More informationDIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
29.3.2014 Official Journal of the European Union L 96/149 DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating
More informationUL Qualified Firestop Contractor Program Management System Elements. March 13, 2013
UL Qualified Firestop Contractor Program Management System Elements March 13, 2013 UL and the UL logo are trademarks of UL LLC 2013 Benefits to becoming a Qualified Firestop Contractor Independent, 3 rd
More informationISO 9001: 2008 Construction Quality Management System Sample - Selected pages (not a complete plan)
ISO 9001: 2008 Construction Quality Management System Sample - Selected pages (not a complete plan) Part 1: Project-Specific Quality Plan Part 2: Company Quality Manual Part 3: Submittal Forms Part 4:
More informationQUALITY MANUAL ISO 9001. Quality Management System
Page 1 of 20 QUALITY MANUAL ISO 9001 Quality Management System Printed copies are not controlled unless marked "CONTROLLED". Upon receipt of this document, discard all previous copies. Page 2 of 20 Approval
More informationProcedures and General Requirements
NIST HB 150-2016 National Voluntary Laboratory Accreditation Program Procedures and General Requirements Warren R. Merkel Vanda R. White This publication is available free of charge from: http://dx.doi.org/10.6028/nist.hb.150-2016
More informationAN AUDIT QUESTIONNAIRE THAT EXAMINES SPECIFICALLY THE MANAGEMENT OF TECHNICAL ACTIVITIES CLAUSES IN ISO 15189
Indian Journal of Clinical Biochemistry, 2010 / 25 (1) 92-98 LABORATORY DOCUMENTATION AN AUDIT QUESTIONNAIRE THAT EXAMINES SPECIFICALLY THE MANAGEMENT OF TECHNICAL ACTIVITIES CLAUSES IN ISO 15189 T F Hartley
More informationMEAT GRADING AND CERTIFICATION BRANCH QUALITY MANUAL
United States Department of Agriculture Marketing and Regulatory Programs Agricultural Marketing Service Livestock and Seed Program Meat Grading & Certification Branch MGC Instruction 800 May 9, 2005 Page
More informationInternal Audit Checklist
Internal Audit Checklist 4.2 Policy Verify required elements Verify management commitment Verify available to the public Verify implementation by tracing links back to policy statement Check review/revisions
More informationAS9100 Quality Manual
Origination Date: August 14, 2009 Document Identifier: Quality Manual Revision Date: 8/5/2015 Revision Level: Q AS 9100 UNCONTROLLED IF PRINTED Page 1 of 17 1 Scope Advanced Companies (Advanced) has established
More informationWORKPLACE HEALTH AND SAFETY AUDITING GUIDELINES
WHS UNIT WORKPLACE HEALTH AND SAFETY AUDITING GUIDELINES Contents 1 Purpose... 1 2 Scope... 1 3 Definitions... 1 4 Responsibilities... 1 4.1 WHS Unit... 1 4.2 Auditor(s)... 1 4.3 Managers of Faculties
More information1 For more information T: +1.847.664.1499 / E: DAP@ul.com / W: ul.com/dap
DATA ACCEPTANCE PROGRAM UL Client Test Data Program Investigations of products by UL typically involve the testing of product samples. While UL maintains extensive facilities for these purposes, customers
More informationNetwork Certification Body
Network Certification Body Scheme rules for assessment of railway projects to requirements of the Railways Interoperability Regulations as a Notified and Designated Body 1 NCB_MS_56 Contents 1 Normative
More informationSMALL BUSINESS OH&S SELF APPRAISAL
SMALL BUSINESS OH&S SELF APPRAISAL This questionnaire is designed to help you judge whether your Occupational Health & Safety Management System (OHSMS) is ready for assessment. Completing this questionnaire
More informationHow To Manage A Quality Management System
Quality Management System Requirements for the Suppliers Of Arçelik A.Ş. Rev : 0.1 Date of issue : September 2005-1/23- -2/23- 0. INTRODUCTION... 5 0.1. GENERAL... 5 1. SCOPE... 5 1.1. GENERAL... 5 1.2.
More informationCOPY. Revision History: Changes were made to reflect the current practice of only including the most recent changes in the revision history.
Revision History COPY The top row of this table shows the most recent changes to this controlled document. For previous revision history information, archived versions of this document are maintained by
More informationMethods verification. Transfer of validated methods into laboratories working routine. Dr. Manuela Schulze 1
Methods verification Transfer of validated methods into laboratories working routine Dr. Manuela Schulze 1 1. Introduction 2. Definitions and differences validation verification 3. How to perform verification
More informationEMS ISO 14001 Checklist
ES IS 14001 hecklist rganization: Auditor: Date: = ajor onconformity = inor onconformity = bservation = omment 4.1 General Requirements 4.1 General requirements maintained an environmental management system
More information