Information Sheet Dissolved Oxygen

Size: px
Start display at page:

Download "Information Sheet Dissolved Oxygen"

Transcription

1 Background Information Sheet Dissolved Oxygen Dissolved oxygen (DO) is the small amount of oxygen gas dissolved in the water. It is essential for the respiration of fish, aquatic animals, micro-organisms and plants. To maintain a healthy and diverse aquatic ecosystem, the dissolved oxygen must be maintained at high levels. If DO falls, there will be reductions or losses in the more sensitive species. At low DO levels, only a very few hardy species may be present. So DO levels are a useful indicator of general water quality. DO levels in natural waters depend on three factors:- 1. Speed of uptake of oxygen into the water from air. This depends on agitation at the water's surface. Shallow flowing streams usually have high oxygen levels while stagnant pools have reduced oxygen. 2. Speed that oxygen is used up in the water. Bacteria will use up oxygen in water. If large amounts of organic matter enter the water course from point sources such as sewage plants and animal feedlots, there will be a high bacterial population and so greater oxygen usage. 3. Photosynthesis of plants and algae. Aquatic plants and algae release large amounts of oxygen into the water in daylight hours as a bi-product of photosynthesis. Peak DO levels occur in early afternoon and minimum levels before sunrise. Since plants produce oxygen during the day through photosynthesis and use it up at night with respiration, the time of the day when the sample is taken should be kept fairly constant and noted on the record sheet. Oxygen levels are also affected by the temperature of the water. Scientific studies suggest that 4.5mg/L DO is the minimum amount that will support a large and diverse fish population. The DO level in good fishing waters generally averages about 9mg/L. When DO levels drop below about 3mg/L, even the hardy fish die. Note: A dissolved oxygen test tells us precisely how much oxygen is dissolved in water, but it does not indicate how much DO the water is capable of holding at

2 the temperature of the test. The percentage saturation is a better measure of the availability of oxygen to aquatic organisms. Sampling Procedure In slow moving streams, make sure to sample away from the shore and midway between the surface and the bottom. In free flowing streams, any sample taken below the surface will be representative.

3 Instructions - Merck DO Kit Equipment Distilled or deionized water Safety gloves and safety glasses Merck dissolved oxygen kit Method 1. Rinse the oxygen reaction bottle with the water to be tested. 2. Fill the bottle to overflowing by submerging the stoppered bottle in the water body and remove the stopper under water. 3. Add 5 drops of Reagent 1 and 5 drops of reagent 2. Close without trapping air bubbles with the slanted stopper and shake for approximately 30 seconds. 4. Add 10 drops of reagent 3. Reseal and shake well again. 5. Rinse the test tube with a small amount of the resultant reaction solution and fill to the 5 ml mark. 6. Place the test tube on the colour card and match the colour to the closest standard colour on the card. You should attempt to estimate the concentration if the colour match appears between the colour standards provided. 7. Report the concentration of dissolved oxygen as mg/l on your result sheet. 8. To convert the mg/l result to % saturation using the conversion graph, mark the temperature of the test sample on the temperature scale. Mark the DO level in mg/l on the concentration scale. Connect the two points and note the value where the line crosses the % saturation line. 9. Report the percentage saturation of dissolved oxygen on your result sheet.

4 Instructions - Visocolor ECO DO Kit Equipment Test kit Safety glasses Safety gloves. Stoppered glass bottle (rinsed with water to be tested). Method 1. Pour a 1ml water sample into on of the measuring glasses and place it on position A in the comparator. 2. Rinse the oxygen reaction bottle several times with the water to be tested and fill until it overflows without air bubbles. 3. Add 5 drops of O Add 5 drops of O 2-2, close the bottle with the stopper (avoid air bubbles) and mix by shaking. 5. After 1 min add 12 drops of O 2-3, close the bottle and shake well until the deposit is dissolved. 6. Pour 1ml of the resultant reaction solution into the second measuring glass and place it on position B in the comparator 7. Slide the comparator until the colours match in the inspection hole on top. Check the measurement reading in the recess on the comparator reed. Mid-values can be estimated. 8. After use, rinse out the oxygen reaction bottle and both measuring glasses thoroughly and seal them. 9. Record the reading on the Physical and Chemical Test Record Sheet.

5 Instructions - Cyberscan DO300/310 Meter Equipment Distilled or deionized water Safety gloves and safety glasses Cyberscan DO 300 dissolved oxygen meter Method 1. Switch on the Cyberscan meter. 2. Calibrate meter to 100% saturation in air. See below. 3. Rinse the probe with distilled rinse water. 4. Select the desired measurement mode by pressing the MODE key to move between modes: a. % Saturation b. mg/l O 2 c. date/time clock 5. Dip the probe into the sample. When the reading is stable, the READY indicator will appear. 6. Report the concentration of dissolved oxygen as mg/l or % saturation on the result sheet.

6 Calibration Air Calibration Note: The exact calibration value depends on barometric pressure. The meter is set to a factory default of 760 mm Hg. See instrument manual to change the pressure setting. To calibrate to 100% Saturation: 1. Switch on the Cyberscan Select the desired measurement mode by using the MODE key to toggle between modes. 3. Plug the Dissolved Oxygen sensor into the sensor socket. 4. Rinse the DO sensor in distilled water and blot dry. Do not touch the membrane. 5. Press the MODE key to select the % saturation mode. 6. Hang the DO sensor pointing downwards in air. 7. Press the CAL button to do an air calibration. 8. Allow the reading to stabilize. The READY indicator will appear when the reading is stable. 9. Press the ENTER key. Note: Since the probe consumes oxygen from the sample, the sample must constantly flow past the membrane for accurate and stable readings.

7 Probe Care and Maintenance The probe consists of two parts: An upper part consisting of an anode, a cathode and cable A lower part made up of a membrane cap, membrane and electrolyte solution. Oxygen diffuses through the membrane onto the cathode. This produces an electrical current that flows to the meter. The current is proportional to the oxygen that passes through the membrane and the layer of electrolyte. Maintenance of Sensor Under typical operating conditions, the probe should last for several years. After using the probe, rinse it in clean water and wipe it with a soft cloth or paper to avoid any deposits. The membrane does not require replacement so long as it remains intact. If the membrane is punctured, or is leaking, it must be replaced. Oils, fats and other greasy substances clinging to the cell will reduce the sensitivity of the sensor. Replace the membrane in this situation rather than cleaning. Storage of Sensor There are no special storage requirements for the probe.

8 Replacing the Membrane Replace the membrane only when the probe cannot be calibrated. Typically membrane problems involve puncture or wrinkles caused during measurements or cleaning. 1. Pull off the probe guard. 2. Unscrew the membrane cap from the probe. 3. Hold the probe under running water and brush away the white oxide on the cylindrical anode with a stiff plastic brush. 4. Using the installation tool, unscrew and remove the membrane lock from the membrane cap. 5. Remove the membrane and O-ring. Discard. 6. Rinse the membrane cap and lock in tap water 7. Install a new O-ring inside the membrane cap. 8. Install a new membrane, making sure that it covers the O-ring all around its circumference. 9. Using the installation tool, screw the membrane lock back into the cap. 10. Tighten the lock firmly over the membrane and O-ring. Do not overtighten. 11. Inspect the membrane for wrinkles. 12. Fill the cap with water to test for leaks. 13. Fill the membrane cap with electrolyte to the brim. 14. Screw the cap onto the probe and replace the probe guard. 15. Calibrate the probe. Note: The membrane can only be used once as it is stretched by the cathode.

9 Checklist During measurement, the probe can be fully or partially immersed in the solution. Do not allow the probe s membrane surface to touch anything. Leave the probe guard attached to the probe at all times. Since the probe consumes oxygen from the sample, the sample must constantly flow passed the membrane to achieve accurate readings. A stirrer may be used to achieve this. Calibrate the instrument to 100% saturation in air before taking any measurements. Re-check that the instrument is measuring 100% saturation in air after the first sample. A zero calibration should be performed monthly. (See Manual for zero calibration instructions)

DISSOLVED OXYGEN PROBE

DISSOLVED OXYGEN PROBE 51970-88 DISSOLVED OXYGEN PROBE Introduction This instruction sheet provides information on the Hach Dissolved Oxygen Probe for use with the sension 6 Dissolved Oxygen Meter. The Dissolved Oxygen Probe

More information

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01 Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery

More information

6 H2O + 6 CO 2 (g) + energy

6 H2O + 6 CO 2 (g) + energy AEROBIC RESPIRATION LAB DO 2.CALC From Biology with Calculators, Vernier Software & Technology, 2000. INTRODUCTION Aerobic cellular respiration is the process of converting the chemical energy of organic

More information

Milwaukee USER MANUAL

Milwaukee USER MANUAL Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the

More information

OxyGuard. Dissolved Oxygen Probe

OxyGuard. Dissolved Oxygen Probe OxyGuard Dissolved Oxygen Probe Standard type USER MANUAL D02 Standard Probe manual gb 0903 CONTENTS 1. DESCRIPTION 1.1 The OxyGuard Probe... 1 1.3 Which kind of transmitter can be used with the OxyGuard

More information

Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor Oxygen, Dissolved DOC316.53.01241 Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor Scope and application: For water, wastewater and process

More information

Operator Quick Guide EC SENSOR

Operator Quick Guide EC SENSOR Operator Quick Guide EC SENSOR Revision G - 24/04/2008 General Information About This Guide The information in this guide has been carefully checked and is believed to be accurate. However, Hach Ultra

More information

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510 User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

Chloride and Salinity

Chloride and Salinity INTRODUCTION Chloride Chloride and Chloride, in the form of the Cl ion, is one of the major inorganic anions, or negative ions, in saltwater and freshwater. It originates from the dissociation of salts,

More information

Trace Dissolved Oxygen Sensor

Trace Dissolved Oxygen Sensor Instruction Sheet PN 51A-499ATRDO/rev.G September 2010 Model 499A TrDO Trace Dissolved Oxygen Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION

More information

Nitrogen, Ammonia. Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Nitrogen, Ammonia. Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table Nitrogen, Ammonia DOC316.53.01234 Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N Scope and application: For wastewater 2. Ammonia ISE 1 Adapted from the Standard Methods for the Examination

More information

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen 1. Check the log-book to see if somebody else has already checked the meter for accuracy within the timeframes below. If the meter hasn

More information

INSTRUCTION MANUAL. Handy Polaris

INSTRUCTION MANUAL. Handy Polaris INSTRUCTION MANUAL Handy Polaris **This page is left blank** Table of Contents 1 General...4 2 Setup...5 2.1 Calibrate...5 2.2 Set Salinity...5 2.3 User Interface...5 2.3.1 Language...5 2.3.2 Temperature

More information

STANDARD OPERATING PROCEDURE Dissolved Oxygen Measurement, Meter Calibration and Maintenance

STANDARD OPERATING PROCEDURE Dissolved Oxygen Measurement, Meter Calibration and Maintenance Page 1 of 9 KEY WORDS- Dissolved Oxygen, calibration, probe preparation, meter preparation APPROVALS APPROVED BY: Kean S. Go, DATE: +/?? APPROVED BY: A Pement DATE: a// A/? f Lisa Ross, EHAP Senior Scientist

More information

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600 User's Guide ExStik DO600 Dissolved Oxygen Meter II RECALL Dissolved Oxygen DO600 Introduction Congratulations on your purchase of the ExStik DO600 dissolved oxygen / temperature meter which simultaneously

More information

Portable Waterproof ph/dissolved Oxygen Meter

Portable Waterproof ph/dissolved Oxygen Meter Notes Write down the name and information of your OKTON distributor here. OPERTING INSTRUTIONS OKTON 35632-Series Portable Waterproof /Dissolved Oxygen Meter WTERPROOF REDY MES % T /Dissolved Oxygen/ /

More information

Dissolved Oxygen Probe (Order Code DO-BTA or DO-DIN)

Dissolved Oxygen Probe (Order Code DO-BTA or DO-DIN) Dissolved Oxygen Probe (Order Code DO-BTA or DO-DIN) The Dissolved Oxygen Probe can be used to measure the concentration of dissolved oxygen in water samples tested in the field or in the laboratory. You

More information

Dissolved Oxygen Sensors

Dissolved Oxygen Sensors Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit

More information

User Guide. 9708 Dissolved Oxygen Probes

User Guide. 9708 Dissolved Oxygen Probes User Guide 9708 Dissolved Oxygen Probes Introduction The Thermo Scientific Orion 9708 dissolved oxygen probe simplifies measurements of dissolved oxygen, particularly Biochemical Oxygen Demand (BOD).

More information

DISSOLVED OXYGEN METER Model : DO-5509

DISSOLVED OXYGEN METER Model : DO-5509 DISSOLVED OXYGEN METER Model : DO-5509 Your purchase of this DISSOLVED OXYGEN METER marks a step forward for you into the field of precision measurement. Although this DISSOLVED OXYGEN METER is a complex

More information

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor CONDUCTIVITY SENSOR Description D0382 Figure 1. The Conductivity Sensor Short Description The Conductivity Sensor can be used to measure either solution conductivity or total ion concentration of aqueous

More information

Instruction Manual HI 9146. Portable Waterproof Microprocessor Dissolved Oxygen Meter

Instruction Manual HI 9146. Portable Waterproof Microprocessor Dissolved Oxygen Meter Instruction Manual HI 9146 Portable Waterproof Microprocessor Dissolved Oxygen Meter w w w. h a n n a i n s t. c o m Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction

More information

For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/.

For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. Instruction Sheet PN 51A-499AOZ/rev.H September 2010 Model 499A OZ Ozone Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS APPLICATION

More information

Portable Waterproof Dissolved Oxygen Meter

Portable Waterproof Dissolved Oxygen Meter Notes Write down the name and information of your OKTON distributor here. OPERTING INSTRUTIONS OKTON 35641-Series Portable Waterproof Dissolved Oxygen Meter WTERPROOF MES T Dissolved Oxygen/ / F Data Meter

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510

User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510 User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

AIRMoN, ph and Conductivity Field Measurement

AIRMoN, ph and Conductivity Field Measurement AIRMoN, ph and Conductivity Field Measurement Items needed: Sample to be measured (sample volume 50 ml) Field Observer Form (FOF) for the sample to be measured conductance cell ph vials, 4 conductivity

More information

Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE

Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE Sodium DOC316.53.01240 Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE Scope and application: For drinking water and process water. Test preparation Instrument-specific information This procedure

More information

Measurement by Ion Selective Electrodes

Measurement by Ion Selective Electrodes Measurement by Ion Selective Electrodes Adrian Vazquez May 8, 2012 Why Use Ion Selective Electrodes? Responsive over a wide concentration range Not affected by color or turbidity of sample Rugged and durable

More information

Oxygen Measurement. with CONTENTS

Oxygen Measurement. with CONTENTS Oxygen Measurement with OxyGuard CONTENTS 1) Some basics... 2 Some Definitions... 3 Oxygen Probes... 4 Fish Farming - Aquaculture... 5 Waste Water Treatment... 7 Safety Monitoring... 7 Foods and Beverages...

More information

PHOTOSYNTHESIS AND RESPIRATION

PHOTOSYNTHESIS AND RESPIRATION PHOTOSYNTHESIS AND RESPIRATION STANDARDS: 3.2.10.B.3, 3.2.10.C.4 3.3.10.B.4 Westminster College INTRODUCTION Plants make sugar, storing the energy of the sun as chemical energy, by the process of photosynthesis.

More information

Lesson 5: Water Conductivity and Total Dissolved Solids Water Quality Sampling

Lesson 5: Water Conductivity and Total Dissolved Solids Water Quality Sampling Lesson 5: Water Conductivity and Total Dissolved Solids Water Quality Sampling Time Frame: Two 45-50 minute class periods Grade Level: 8 th 12 th Grade Overview: There are a wide variety of inorganic substances

More information

2 (. 3 4 5 . -,.. -,. 3. : 1 2 3 > 4, :!! 1,, 17 Lt MAX 2 3 4,, > 5.,,, 6 :, :1)! 2)! 7,, 1, :,. 2,, Bottom of steam generator 7 8 9 10 11 12 automatically and this phenomenon will continue for

More information

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007 Instruction Sheet PN 51A-499AOZ/rev.F January 2007 Model 499A OZ Ozone Sensor For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit our website at www.emersonprocess.com/raihome/liquid/.

More information

Color, True and Apparent

Color, True and Apparent Color, True and Apparent DOC316.53.01037 Platinum-Cobalt Standard Method 1, 2, 3 Method 8025 15 to 500 color units Scope and application: For water, wastewater and seawater; equivalent to NCASI method

More information

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL 970 350/REV A/10-03 MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL CONTENTS Introduction 1 Specification 1 Installation 2 Displays 2-3 Controls 4 Preparation

More information

Color, True and Apparent

Color, True and Apparent Color, True and Apparent DOC316.53.01037 Platinum-Cobalt Standard Method 1, 2, 3 Method 8025 15 to 500 color units 5 to 500 color units (low range technique) Scope and application: For water, wastewater

More information

SenTix 950 SenTix 980

SenTix 950 SenTix 980 SenTix 950 SenTix 980 ph combination electrodes with refillable liquid reference system Operating manual ba75843e01 08/2009 SenTix The latest version of the present operating manual can be found on the

More information

Where the exp subscripts refer to the experimental temperature and pressure acquired in the laboratory.

Where the exp subscripts refer to the experimental temperature and pressure acquired in the laboratory. Molar Volume of Carbon Dioxide Reading assignment: Julia Burdge, Chemistry 3rd edition, Chapter 10. Goals To determine the molar volume of carbon dioxide gas and the amount of sodium carbonate in a sample.

More information

Care and use guide. Contents. a handy solution made easy. www.getbluelab.com. page

Care and use guide. Contents. a handy solution made easy. www.getbluelab.com. page Care and use guide Contents page Features Quick guide Before use To operate Important - ph pen probe care 4 Cleaning 5 Battery replacement 5 Hydration 6 Calibration 6 Error messages 7 Troubleshooting guide

More information

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN 903565 or 4317588).

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN 903565 or 4317588). User Bulletin ABI PRISM 310 Genetic Analyzer 01/2007 SUBJECT: Syringe Care and Maintenance Overview Safety Information Warranty Information In this User Bulletin This user bulletin describes the care,

More information

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3 Measuring ph in Water or CaCl2 Using a ph Meter Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3 PREPARING THE ph METER FOR USE (Calibration and Buffer Solutions) 4 When is Calibration

More information

USEPA Electrode Method Method 8156

USEPA Electrode Method Method 8156 ph DOC316.53.01245 USEPA Electrode Method Method 8156 Scope and application: For drinking water 1, wastewater 2 and process water. 1 Based on Standard Method 4500-H+B, ASTM Method D1293-95 and USEPA Method

More information

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills Overview: This is a guidance document that is intended for users of YSI 6-Series sondes and handheld instruments

More information

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point.. Identification of a Substance by Physical Properties 2009 by David A. Katz. All rights reserved. Permission for academic use provided the original copyright is included Every substance has a unique set

More information

Private Water Supplies Sampling Manual. A Field Guide

Private Water Supplies Sampling Manual. A Field Guide Private Water Supplies Sampling Manual A Field Guide Foreword This sampling manual details standard procedures for the collection, storage and transportation of samples at private water supplies in accordance

More information

Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific

More information

Appendix C. Vernier Tutorial

Appendix C. Vernier Tutorial C-1. Vernier Tutorial Introduction: In this lab course, you will collect, analyze and interpret data. The purpose of this tutorial is to teach you how to use the Vernier System to collect and transfer

More information

Instruction Manual DO 110. Hand-held Dissolved Oxygen Meter with RS 232C. 68X361305 Rev. 0-11/05. Technology Made Easy...

Instruction Manual DO 110. Hand-held Dissolved Oxygen Meter with RS 232C. 68X361305 Rev. 0-11/05. Technology Made Easy... Instruction Manual DO 110 Hand-held Dissolved Oxygen Meter with RS 232C Technology Made Easy... 68X361305 Rev. 0-11/05 Preface This manual serves to explain the use of the hand-held series meters. The

More information

ExStik TM ph Waterproof Meters

ExStik TM ph Waterproof Meters User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL

More information

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending User Guide ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens Patent Pending Getting Started Remove the cap from the bottom of the ExStik TM to expose the electrode bulb and reference

More information

Model MC-82 Dissolved Oxygen Temp. Meter Handbook Version : 1.0

Model MC-82 Dissolved Oxygen Temp. Meter Handbook Version : 1.0 Congratulations! You have purchased the latest in Handheld Dissolved Oxygen-Temperature instrumentation. We trust that your new MC-82 will give you many years of reliable service. The MC-82 is a breeze

More information

The Influence of Carbon Dioxide on Algae Growth

The Influence of Carbon Dioxide on Algae Growth The Influence of Carbon Dioxide on Algae Growth The first objective of this experiment is to show that increased atmospheric concentrations of carbon dioxide, CO 2, can stimulate algae growth. The second

More information

Relative Humidity Calibration Kit

Relative Humidity Calibration Kit Revised 6.8.12 Relative Humidity Calibration Kit For Calibrating All RH Measuring Kestrel Meters Model Numbers 3000, 3500, 4000, 4200, 4250, 4300, 4400, 4500 2011 Nielsen-Kellerman Co. While the calibration

More information

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

SCREAMIN' EAGLE HEAVY BREATHER PERFORMANCE AIR CLEANER KIT REV. 2015-04-23 SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT GENERAL Kit Numbers 29299-08, 29098-09 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories

More information

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

SCREAMIN' EAGLE HEAVY BREATHER PERFORMANCE AIR CLEANER KIT REV. 05-04- SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT GENERAL Kit Numbers 95-08B, 9006-09B, 876-0A Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories

More information

Enzyme Action: Testing Catalase Activity

Enzyme Action: Testing Catalase Activity Enzyme Action: Testing Catalase Activity Experiment 6A Many organisms can decompose hydrogen peroxide (H 2 O 2 ) enzymatically. Enzymes are globular proteins, responsible for most of the chemical activities

More information

Professional Plus. Calibration Tips

Professional Plus. Calibration Tips Professional Plus Calibration Tips Table of Contents Introduction...1 Calibration Worksheet...1 Temperature...3 Calibration Tips...3 Troubleshooting Tips...3 Conductivity...4 Calibration Tips...4 Troubleshooting

More information

18 Conductometric Titration

18 Conductometric Titration Lab Activity 18 CONDUCTOMETRIC TITRATION LAB ACTIVITY 18 Conductometric Titration Background Titration is the a method of determining the concentration of an unknown solution (the analyte) by reacting

More information

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques Introduction The amount of dissolved oxygen in process water is continually gaining importance in many industries as a critical parameter

More information

The Determination of an Equilibrium Constant

The Determination of an Equilibrium Constant The Determination of an Equilibrium Constant Computer 10 Chemical reactions occur to reach a state of equilibrium. The equilibrium state can be characterized by quantitatively defining its equilibrium

More information

Photosynthesis and Respiration

Photosynthesis and Respiration Photosynthesis and Respiration Experiment 31C Plants make sugar, storing the energy of the sun into chemical energy, by the process of photosynthesis. When they require energy, they can tap the stored

More information

Phosphates (ortho- and total)

Phosphates (ortho- and total) INTRODUCTION Phosphates (ortho- and total) Phosphorus is an essential nutrient for all aquatic plants and algae. Only a very small amount is needed, however, so an excess of phosphorus can easily occur.

More information

PART 1 - INTRODUCTION...

PART 1 - INTRODUCTION... Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART

More information

ph Measurement and Control

ph Measurement and Control ph Measurement and Control Tech Tip #14 1997 I. The Need for ph II. ph System Requirements III. ph Electrode Conditioning Procedures IV. How the electrode works V. Identifying the Electrode Components

More information

SINGLE RANGE DS METERS Operation Instructions

SINGLE RANGE DS METERS Operation Instructions SINGLE RANGE DS METERS Operation Instructions User Manual for Models 512T2 512T3 512T4 512T5 512T10 512M2 512M3 512M4 512M5 512M10 6115 Corte del Cedro Carlsbad, CA 92009-1516 USA Tel 760-438-2021 Fax

More information

UltraBasic Benchtop ph Meter Operation Manual

UltraBasic Benchtop ph Meter Operation Manual UltraBasic Benchtop Meter Operation Manual UB-5 Denver Instrument Measuring 4 4 7 10 Meter 22.2 C 4.06 UltraBasic 902388.1 Rev. A UltraBasic Meter Quick Reference 1. Connect a AC adapter to the power connection.

More information

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual Dissolved Oxygen Meter Operator s Manual Newport Electronics, Inc. Additional products from Newport Electronics, Inc. THE NEW STANDARD FOR QUALITY Clock/Timers Counters Flow Sensors Frequency Meters Multimeters

More information

How Dense is SALT WATER? Focus Question What is the relationship between density and salinity?

How Dense is SALT WATER? Focus Question What is the relationship between density and salinity? Focus Question What is the relationship between density and salinity? Activity Overview Fresh water from the Mississippi River pours into the salty ocean water in the Gulf of Mexico. More than 152,400

More information

Metabolism: Cellular Respiration, Fermentation and Photosynthesis

Metabolism: Cellular Respiration, Fermentation and Photosynthesis Metabolism: Cellular Respiration, Fermentation and Photosynthesis Introduction: All organisms require a supply of energy and matter to build themselves and to continue to function. To get that supply of

More information

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

NESCAFÉ Solution 8/60 Beverage System. Operations Manual NESCAFÉ Solution 8/60 Beverage System Operations Manual 1 INDEX & WARNINGS INDEX Warnings SECTION: 1 INDEX & WARNINGS SECTION: 2 BASIC PARTS OF THE MACHINE SECTION: 3 LOADING PRODUCTS SECTION: 4 DISPENSING

More information

Ultrasonic support removal tank

Ultrasonic support removal tank Ultrasonic support removal tank User guide and safety manual See inside for use and safety information. The Ultrasonic support removal tank automatically removes PLA support material from a printed ABS

More information

ph Measurements of Common Substances

ph Measurements of Common Substances Chem 100 Section Experiment 10 Name Partner s Name Introduction ph Measurements of Common Substances The concentration of an acid or base is frequently expressed as ph. Historically, ph stands for the

More information

Acid Base Titrations

Acid Base Titrations Acid Base Titrations Introduction A common question chemists have to answer is how much of something is present in a sample or a product. If the product contains an acid or base, this question is usually

More information

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter. 5940506

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter. 5940506 Chlorine, Total DOC316.53.01029 USEPA DPD Method 1 Method 10070 0.1 to 10.0 mg/l Cl 2 (HR) Powder Pillows Scope and application: For testing higher levels of total chlorine (free and combined) in drinking

More information

Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856

Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows

More information

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

Operating Instructions & Maintenance Guidelines for Precision Vaporizers Operating Instructions & Maintenance Guidelines for Precision Vaporizers This page intentionally blank. Examination and Preparation for Use We want you to be completely satisfied with your vaporizer. Please

More information

Transpiration. C should equal D.BUT SOMETIMES. 1. Loss in mass is greater than volume of water added.

Transpiration. C should equal D.BUT SOMETIMES. 1. Loss in mass is greater than volume of water added. Transpiration Transpiration is the loss of water by evaporation from the leaves through the stomata. The source of water for the plants is soil water. It is taken up by root hair cells by osmosis. Once

More information

CSUS Department of Chemistry Experiment 8 Chem.1A

CSUS Department of Chemistry Experiment 8 Chem.1A EXPERIMENT #8 Name: PRE-LABORATORY ASSIGNMENT: Lab Section 1. The alkali metals are so reactive that they react directly with water in the absence of acid. For example, potassium reacts with water as follows:

More information

Manual for GlobePharma Mini-Press II Rotary Tablet Press

Manual for GlobePharma Mini-Press II Rotary Tablet Press 1 of 13 Preparing the Rotary Press 1. Make sure the rotary press is unplugged. 2. Open the bottom cabinet of the rotary press and take out the grey tool kit, and the beige box of punches and dies. 3. Take

More information

TEACHER ACTIVITY GUIDE

TEACHER ACTIVITY GUIDE Page 1/5 EXPECTED OUTCOMES TEACHER ACTIVITY GUIDE ROOT BEER PRODUCTION Taken from IFT Experiments in Food Science Series This activity will allow student an opportunity to explore yeast fermentation by

More information

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN 2011. In Use Date: 2/1/2011 Discontinued Date:

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN 2011. In Use Date: 2/1/2011 Discontinued Date: PROCEDURE COVERSHEET Procedure Title: ph (Urine, Body Fluid, Platelet Samples) Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN 2011 Laboratory Director: TED KURTZ, MD (PARNASSUS & CHINA

More information

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev. Instruction Sheet PN 51A-397/rev.F January 2011 Model 397 ph Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS MODEL 397 PERFORMANCE

More information

Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions

Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions Safety precautions Naphthalene is harmful if swallowed. May cause cancer. Is further very toxic to aquatic organisms and can have long-term harmful effects in bodies of water. Equipment 1 Bomb calorimeter

More information

PR 50 Frymaster Universal Holding Cabinet (UHC)

PR 50 Frymaster Universal Holding Cabinet (UHC) PREP EQUIPMENT PR 50 Frymaster Universal Holding Cabinet (UHC) Models UHCP2, UHCP4, UHCPN4 Daily maintenance tasks PR 50 D1 Clean UHC Monthly maintenance tasks PR 50 M1 Calibrate UHC Annual maintenance

More information

Dissolved Oxygen and Aquatic Primary Productivity1

Dissolved Oxygen and Aquatic Primary Productivity1 Dissolved Oxygen and Aquatic Primary Productivity1 INTRODUCTION 2 Oxygen is critical to the maintenance of the life processes of nearly all organisms. In the aquatic environment, oxygen must be in solution

More information

The Molar Mass of a Gas

The Molar Mass of a Gas The Molar Mass of a Gas Goals The purpose of this experiment is to determine the number of grams per mole of a gas by measuring the pressure, volume, temperature, and mass of a sample. Terms to Know Molar

More information

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL 430 350/REV A/10-03 MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL CONTENTS Introduction 1 Specification 2 Installation 3 Displays 3-4

More information

Operations Manual. YSI 550A Dissolved Oxygen Instrument

Operations Manual. YSI 550A Dissolved Oxygen Instrument YSI 550A Dissolved Oxygen Instrument Operations Manual CONTENTS CONTENTS...iii GENERAL DESCRIPTION...1 WARRANTY...2 FEATURES OF THE YSI 550A...3 PRINCIPLES OF OPERATION...5 PREPARING THE PROBE...5 DISSOLVED

More information

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0 ACID-BASE TITRATION LAB PH 2.PALM INTRODUCTION Acids and bases represent a major class of chemical substances. We encounter them every day as we eat, clean our homes and ourselves, and perform many other

More information

USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls Iron, Total DOC316.53.01053 USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater; digestion is required

More information

After the reactor has been running and the air in the chamber has been purged the co2 can be introduced and the dial in process can begin.

After the reactor has been running and the air in the chamber has been purged the co2 can be introduced and the dial in process can begin. About Calcium Reactors: A calcium reactor is a device that dissolves calcium carbonate by using co2 gas to create an acidic condition within the reaction chamber. A circulation pump is used to move the

More information

LAB 24 Transpiration

LAB 24 Transpiration Name: AP Biology Lab 24 LAB 24 Transpiration Objectives: To understand how water moves from roots to leaves in terms of the physical/chemical properties of water and the forces provided by differences

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Temperature Sensor: WQ101 ph Sensor: WQ201 Conductivity Sensor: WQ301

More information

HOBO Dissolved Oxygen Logger (U26-001) Manual

HOBO Dissolved Oxygen Logger (U26-001) Manual HOBO Dissolved Oxygen Logger (U26-001) Manual The HOBO Dissolved Oxygen logger is a standalone logger that uses RDO Basic Technology to measure dissolved oxygen (DO). The logger has an optical sensor that

More information

Shampoo Properties Evaluation General Science

Shampoo Properties Evaluation General Science / 10 Shampoo Properties Evaluation General Science Name It is difficult to obtain exact information on the formulation of commercial shampoos. These facts are held by the manufacturer to protect their

More information

Balzers Sputter Coater SCD 050

Balzers Sputter Coater SCD 050 Balzers Sputter Coater SCD 050 The SCD 050 is a bench top, sputter deposition system designed for thin films on substrates up to 6 inches. Morphology and thickness is user controlled using power, pressure,

More information

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed: Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Your Name: Date: Partner(s) Names: Objectives: React magnesium metal with hydrochloric acid, collecting the hydrogen over water. Calculate the grams

More information

Catalytic Activity of Enzymes

Catalytic Activity of Enzymes Catalytic Activity of Enzymes Introduction Enzymes are biological molecules that catalyze (speed up) chemical reactions. You could call enzymes the Builders and Do-ers in the cell; without them, life could

More information

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law. Conductivity of strong and weak electrolytes TEC Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law. Principle It is possible to

More information

Water Hardness. Evaluation copy

Water Hardness. Evaluation copy Water Hardness Experiment 11 When water passes through or over mineral deposits such as limestone, the levels of certain ions present in the water increase greatly and cause the water to be classified

More information