CE 479: DESIGN OF BUILDING COMPONENTS AND SYSTEMS FALL 2012 J. LIU. Wood Structural Panels
|
|
- Anna Clementine Phelps
- 7 years ago
- Views:
Transcription
1 CE 479: DESIGN OF BUILDING COMPONENTS AND SYSTEMS FALL 2012 J. LIU Wood Structural Panels
2 Wood Structural Panels Plywood Oriented Strand Board (OSB) Composite Panels Generally, wood veneer and reconstituted wood-based material bonded Particleboard Medium density fiberboard
3 Wood Structural Panels Composite Panels Particleboard made from small wood particles pressed together with glue under extreme heat and pressure to make a solid panel. Medium density fiberboard made the same way except the wood particles are further refined into even smaller particles to provide a smooth edge to the panel.
4 Uses Roof, floor and wall sheathing Horizontal and vertical (shearwall) diaphragms Structural components Prefab. I-joists Sandwich panels Gusset plates Concrete formwork
5 Sheathing
6 Sheathing Thickness requirements Often determined by sheathing-type loads (normal to surface of panel) Nailing requirements Determined by unit shears in horizontal or vertical diaphragm More later on both topics
7 Panel Dimensions and Installation Standard size 4 x 8 ft Can be available in 9, 10, 12 ft lengths Dimensionally stable But some changes can be expected under varying moisture conditions Installation recommend clearance between panel edges and ends Typically 1/8 in to permit panel movement Other spacing provisions may apply, depending on type of panel, moisture conditions
8 Installation Typical tolerances +0, -1/16 in., and +0, -1/8 in. Some panel grade stamps: sized for spacing Allow for panel spacing while maintaining basic 4 ft. module Nail popping If installed on green beams, nails should be set below surface of sheathing (will appear to pop upwards as supports dry)
9 Plywood Plywood panel made up of a number of veneers (thin sheets of wood) Veneer obtained by rotating peeler logs in a lathe
10 Plywood Veneer then clipped to proper size Dried to low moisture content (2 5 %) Graded according to quality Veneer spread with glue and cross-laminated Adjacent layers have wood grain at right angles Odd number of layers Glue bond obtained is stronger than wood in plies Panel is grade-stamped
11 3 ply, 3 layer panel
12 4 ply, 3 layer panel Extension of simple 3-ply construction Two center plies have grain running in same direction
13 5 ply, 5 layer panel
14 Plywood Layers Face Outside ply (if outside plies are different veneer quality, face is the better veneer grade) Grain oriented typically parallel to 8 ft dim. Back The other outside ply (grain also parallel to 8 ft. dim.) Crossband Inner layer(s) placed at right angles to face and back Center Inner layer(s) parallel with outside plies
15 Plywood orientation Strong orientation Grain of outside layers parallel to span Weak orientation Grain of outside layers perpendicular to span Thus, two sets of cross-sectional properties for use with stresses, depending on orientation (stress and properties tables) Also, load tables for sizing
16 Design Values / Load Tables 2005 ASD/LRFD Manual For Engineered Wood Construction We ll use this: Load-Span Tables for APA Structural-Use Panels
17 Transformed sections (used to develop load tables)
18 Strong Orientation Weak Orientation
19 Species Groups for Plywood
20 Species Groups for Plywood Group1 highest stiffness and strength; Group 5 lowest Groups 1 to 4 reference design values Mixing of species? Reference design values based on species group of face and back plies Species group of outer plies included in grade stamp
21 Veneer Grades N special order natural finish veneer A smooth, paintable surface, without knots B solid-surface veneer, may contain knots up to 1 in. in width if sound and tight-fitting C-plugged improved C-grade with knotholes less than ¼ x ½ in C may contain open knotholes up to 1 in. in width and some up to 1-1/2 in. D open knotholes up to 2-1/2 in., occasional up to 3 in. across grain (not allowed in exterior applications)
22 Exposure Durability Exterior Insoluble waterproof glue Minimum of C-grade veneers Required when permanently exposed to weather or when MC will exceed 18% (continuously or in repeated cycles) Interior Not exposed to weather or exceed 18% MC Typically available with exterior glue, but can be with exterior, interior, or intermediate Exposure 1 if exterior glue; might be used if long construction delays (exposure) expected
23 Marine grade plywood Gap and void-free in all layers No voids even on cut edges Water-proof glue Water has no effect on glue when immersed Typically constructed of harder woods such as Douglas Fir or Western Larch
24 Plywood Grade Stamps Veneer grades of face and back Minimum species group of the outer plies Highest species group number Exposure durability classification Mill number Inspection agency PS-1 (U.S. Product Standard PS-1 Construction and Industrial Plywood)
25 Plywood Grade Stamp APA American Plywood Association GRADE OF VENEER ON PANEL FACE GRADE OF VENEER ON PANEL BACK SPECIES GROUP NUMBER DESIGNATES TYPE ON EXTERIOR OR INTERIOR PLYWOOD STANDARD GOVERNING MANUFACTURE MILL NUMBER
26 Plywood Grades Sheathing Grades Normally used for roof, floor, wall sheathing C-C (exterior type) C-D (typically Exposure 1) When added strength required: STRUCTURAL 1 can be added to designation CC-STR 1 or C-D STR 1
27 Plywood Grades Span Rating (e.g. 24/16) Number on left is maximum recommended span in inches when used as roof sheathing Second number is maximum recommended span in inches when used a subflooring Meant for use of panels without any structural calculations Panel must be oriented in the strong direction Certain edge support requirements must be satisfied May use panels for longer spans if justified by structural calculations
28 Plywood May be sanded Improves surface condition However, reduces thickness of outer veneers Different cross-sectional properties are used in strength calculations for sanded, touch-sanded, and unsanded panels Or, different tables, such as Table 3 for Group 1 Sanded Plywood panels (APA, 2011)
29 Oriented Strand Board Non-veneer panel manufactured from reconstituted wood strands or wafers, bonded with resin Strands directionally oriented, typically in 3 to 5 perpendicular layers, cross laminated in similar manner to plywood
30 Nonveneer (OSB) Grade Stamp
31 Adjustment Factors NDS Table Applicability of Adjustment Factors for Wood Structural Panels C M and C t obtain from approved source (such as APA, NDS commentary) New for panels C S Panel Size Factor If panel width < 24 NDS Table 9.3.4
32 Adjustments ASD only Span Adjustments: 2-span to 1-Span 3-span to 1-Span 3-span to 2-Span Wet Locations, C M MC 16% or more
33 Roof Sheathing Example Consider roof system with sheathing span of 24 inches, dead load of 10 psf, snow load of 75 psf, total load deflection limit of L/240. Determine the minimum span-rated sheathing using LRFD. Use strength axis across supports. Assume sheathing grade, 3-span, 4-ply, normal temperatures, dry service conditions. 1.4 D = 1.4 (10 psf) = 14 psf 1.2 D S = 1.2 (10 psf) (75 psf) = 132 psf D + S = 10 psf + 75 psf = 85 psf
34 Roof Sheathing Example, cont d. Note: Tables are ASD! Assumes 3 spans (No span adjustment needed) Assumes 2 spans
35 Roof Sheathing Example, cont d. Note: Tables are ASD!
36 Roof Sheathing Example, cont d. Note: no adjustment for, or mention of, 3-ply, 4-ply, etc. in Load Tables May not know # of plies (i.e., not on grade stamp), therefore tabulated values based on most conservative construction (Table 6)
37
38 Roof Sheathing Example, cont d. For Deflection, no modification; same for ASD and LRFD 32/16 does not satisfy deflection limit, but 40/20 does 163 > 85 psf (D+S)
39 Roof Sheathing Example, cont d. Bending: K F (130psf) = 2.54 (130 psf) = 330 psf Shear: K F (218 psf) = 2.88 (218 psf) = 628 psf
40 Roof Sheathing Example, cont d. = 0.8 for 1.2 D S b = 0.85 and v = 0.75 Bending: 330 psf (0.8)(0.85) = 224 psf Shear: 628 psf (0.8)(0.75)= 377 psf Both > 132 psf OK! Use 40/20 sheathing
41 Roof Sheathing Span ratings assume panel edge support Support intended to limit differential movement between adjacent panels Unsupported edge may require thicker panel or closer joist spacing Lumber blocking cut and fitted between roof joists Tongue and groove edges Panel clips metal H-shaped clips placed between plywood edges
42 Floor Sheathing Floor systems may use two layers of panels or a single layer Subfloor bottom layer in a two-layer system (the basic structural sheathing material) Underlayment the top layer in a two-layer system Combined subfloor-underlayment a single layer system (usually with nontextile flooring) A finish floor such as tile, hardwood, carpeting usually provided
43 Underlayment Purpose is to provide solid surface for application of floor finish Grade: Underlayment Typical thickness ¼ in. for remodeling and use over panel subfloor and 3/8 to ½ in. for use over lumber subfloor or new construction When finish floor has some structural capacity (e.g. wood strip flooring, lightweight concrete) underlayment is not required
44 Subfloor Panels must be used in strong direction and continuous over two or more spans Differential movement at panel edges must be limited by: T&G edges Blocking ¼ in. underlayment with panel edges offset over subfloor Finish floor of ¾ in. wood strips 1-1/2 in. of lightweight concrete
45 Single-Layer Floor Systems Performance rated panels known as Sturd-I-Floor Include plywood, composite, and non-veneer panels
46 Floor Sheathing Example APA-rated Plywood Sturd-I-Floor is considered for an office building subfloor. The floor utilizes a twolayer floor system with a separate subfloor and underlayment. A ¼ in. plywood UNDERLAYMENTgrade panel is used over the subfloor; its joints are staggered with respect to the joints in the subfloor (no special edge support is required). Assume strength axis perpendicular to supports, 3-span, 4- ply, normal temperature, but MC at 16% or more.
47 Floor Sheathing Example, cont d. Dead load 12 psf, distributed (moveable)partition load of 15 psf, floor live load of 50 psf. (L from occupancy) Floor framing members spaced at 16 in. o.c. Floor system must satisfy live load deflection limit of L/360 and total deflection limit of L/ D L = 1.2 (12 psf) (65 psf) = 118 psf D + L = 12 psf + 65 psf = 77 psf
48 Floor Sheathing Example, cont d.
49 Floor Sheathing Example, cont d.
50 Floor Sheathing Example, cont d. For Deflection, modify by C M only 270(0.85)=230 > 65 LL And 405(0.85)=344 > 77 TL OK! Bending: K F (213 psf) = 2.54 (213 psf) = 541 psf Shear: K F (338 psf) = 2.88 (338 psf) = 973 psf
51 Floor Sheathing Example, cont d. = 0.8 for 1.2 D L (occupancy) b = 0.85, v = 0.75, C M = 0.75 Bending: 541 psf (0.8)(0.85)(0.75) = 276 psf Shear: 973 psf (0.8)(0.75)(0.75) = 438 psf Both > 118 psf OK! USE 16 oc APA-rated Sturd-I-Floor
52 Floor Example What if we have a 1-span condition? For Deflection, 270(0.85)(0.53) =122 > 65 LL 405(0.85)(0.53)=182 > 77 TL OK! Bending: 541 psf (0.8)(0.85)(0.75)(0.8) = 221 psf Shear: 973 psf (0.8)(0.75)(0.75)(1.2) = 527 psf > 118 psf OK! USE 16 oc APA-rated Sturd-I-Floor
53 Wall Sheathing Two basic uses: Structural only: as sheathing to distribute normal wind forces to the studs or function as basic shearresisting elements (shearwalls) Combined sheathing-siding
54 Wall Sheathing Sizing for sheathing-type loads (wind loads normal to panels) same procedure as for floor and roof sheathing Design as shear walls later topic!
LP OSB Sheathing & Structural 1 Sheathing
Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48
More informationLoad-Span Tables for PS-1 Plywood
T E C H N I C A L N O T E -Span Tables for PS-1 Plywood Number Z802K March 1998 -span tables for specific wood structural panel applications are included in several APA publications. Recommended loads
More informationB. Related categories: The following categories contain requirements that relate to this section:
ORIENTED STRAND BOARD PART I. - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply
More informationStructural Plywood. Design and Application Guide
Structural Plywood Design and Application Guide INTRODUCTION Plywood as we know it has been produced since early in the 20th century. It has been in widespread use as sheathing in residential and commercial
More informationChapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
More informationHow To Make An Oriented Strand Board
ABOUT COMPANY Mission Provide solutions to enchance customers product value. Vision - To be a leader among wood based panel producers in the region. Values Innovation, integrity and team commitment. BOLDERAJA
More informationDecember 2013. J-Ply Roofing, Flooring and Decking
December 2013 J-Ply Roofing, Flooring and Decking Introduction J-Ply plywood is manufactured in New Zealand by Juken New Zealand Limited (JNL) and marketed by New Zealand Wood Products Limited. The J-Ply
More informationPost and Beam Construction
Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America
More informationFormwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
More informationGeneral Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout
General Approach Sketch general structural layout Determine roof loading Determine required lumber dimensions Transfer load down the structure Structure Components Plants Structure Components Top Side
More informationHURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
More informationPOST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationNanping Weishi LVL Scaffold Plank Brochure
Nanping Weishi LVL Scaffold Plank Brochure Weishi Wood Inudstry Co., Ltd. is PFS Certified Mill. Weishi Planks are OSHA Compliant Products. Weishi Team is Aimed to Offer You the Best Quality and Service.
More informationThe better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
More informationReport on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.
Report on Sanctuary/Chancel Crawl Space Inspection St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove Project No. E112056 1. Background St. John in the Wilderness (SJITW) is considering
More informationMark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
More informationOwner s Guide to Understanding Checks in Glued Laminated Timber
Owner s Guide to Understanding Checks in Glued Laminated Timber ENGINEERED WOOD SYSTEMS Checking In Glued Laminated Timber Glued laminated timber (glulam) is an engineered wood product that is used in
More informationTECHNICAL RESOURCE SHEET. Minimize the chance for accidents by installing panels with the textured side up.
TECHNICAL RESOURCE SHEET FLOOR, roof and wall PANEL installation Achieving optimum performance with Weyerhaeuser Edge and Edge Gold oriented strand board (OSB) flooring and Weyerhaeuser sheathing depends
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationGuide Specifications for Maple Flooring Systems
Guide Specifications for Maple Flooring Systems MFMA Guide Specification for Resilient Pre-Engineered Fixed Panel System Purpose This Guide Specification is designed to assist in the production of actual
More informationDesign of Cold-Formed Steel Shear Walls
DESIGN GUIDE 2 Design of Cold-Formed Steel Shear Walls March 1998 The following publication was developed by R.L. Brockenbrough & Associates for the American Iron and Steel Institute (AISI), In the production
More informationFeaturing TJ Rim Board and TimberStrand LSL
#TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and TimberStrand LSL Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load
More informationFoundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
More informationSTANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationPERFORMANCE RATED I-JOISTS
PERFORMANCE RATED I-JOISTS ENGINEERED WOOD SYSTEMS 2 WOOD The Miracle Material Wood is the right choice for a host of construction applications. It is the earth s natural, energy efficient and renewable
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More informationBUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof.
BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof. 1155 & 4155 LCL: Applies to all freight in less than container load quantities.
More informationUncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
More information6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
More informationLoad Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. www.r-control.com CONTROL, NOT COMPROMISE.
R-CONTROL s STRUCTURAL INSULATED PANELS Note: Information deemed reliable at time of printing. Please visit www.r-control.com for latest information. June 2012 CONTROL, NOT COMPROMISE. www.r-control.com
More informationBuilding Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
More informationAUTHORIZATION TO MARK
AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set
More informationHow To Install Hardwood Flooring
phone: 1.855.Ludaire e-mail: info@ludaire.com Solid Flooring Installation Instructions These Instructions and Guidelines are for the typical installation of ¾ Pre-finished Solid Hardwood Flooring manufactured
More informationPage & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
More informationResidential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks
More informationSection A Roof Truss
Section A Roof Truss Truss Types Wisconsin Truss, Inc. can build a variety of truss types, pictured below are some common examples. Common Bobtail Scissor Mono Studio Dual Slope Cathedral Tray Vault Parallel
More information9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.
Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and
More informationRenovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
More informationFig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
More informationDESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,
DESIGN OF SLABS Dr. G. P. Chandradhara Professor of Civil Engineering S. J. College of Engineering Mysore 1. GENERAL A slab is a flat two dimensional planar structural element having thickness small compared
More informationMUNICODE SERVICES LTD.
The Preserved Wood Foundation Guide MUNICODE SERVICES LTD. Prepared by MuniCode Services Ltd. Outline and Restrictions of this Guide The following information required for the construction of Preserved
More informationCustom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
More informationINTERGOVERNMENTAL STANDARD GOST 3916.1-96
INTERGOVERNMENTAL STANDARD GOST 3916.1-96 Plywood with outer layers of deciduous veneer for general use. Contents DESCRIPTION GENERAL USE PWOOD CLASSIFICATION AND DIMENSIONS( table1,2) TECHICAL REQUIREMENTS
More informationFire Preventive and Fireproof Performance Test and Evaluation Procedure Manual
BR BO-01-02 Effective from June 1, 2000 Revision: March 26, 2002 Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual (Unofficial Manual) Technical Appraisal Department, Building
More informationLEGACY REPORT. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council RETAINED ON U.S.
ICC-ES Legacy Report ER-5043* Reissued March 2004 www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council Legacy report on the 1997 Uniform Building Code DIVISION: 09
More informationHerringbone Pattern Flooring
Herringbone Pattern Flooring If it s not marked NOFMA, it s not certified. Handling, Storage, Installation and Tips Herringbone is generally manufactured from 3/4 x 2 ¼ or ¾ x 1-1/2 standard tongue & groove
More informationTimber Decks. Technical Note. March 2007
Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.
More informationChapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.
Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION
More informationSUPER SHED. Indoor shelter for your outdoor tools.
SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because
More informationIndex 20010 Series Prestressed Florida-I Beams (Rev. 07/12)
Index 20010 Series Prestressed Florida-I Beams (Rev. 07/12) Design Criteria AASHTO LRFD Bridge Design Specifications, 6th Edition; Structures Detailing Manual (SDM); Structures Design Guidelines (SDG)
More informationEurocode 5: Design of timber structures
Eurocode 5: Design of timber structures Arnold Page, BSc, BD, MIWSc. Structural timber engineering consultant Introduction BS EN 1995 consists of three parts: Part 1-1: General. Common rules and rules
More informationCommon Errors in Truss Design
In today s competitive world of trusses, component manufacturers are always looking for ways to generate more efficient truss designs. Occasionally, truss designs need to be changed in order to be sealed
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationBracing Webs in Trusses that have Dissimilar Configurations
Bracing Webs in Trusses that have Dissimilar Configurations Released April 25, 2006 Issue: Truss Design Drawings (TDD) that are prepared in accordance with ANSI/TPI 1, National Design Standard for Metal
More informationBella Cera Engineered Hardwood Flooring Installation Instructions. Check for Proper Color Selection Prior to Installation
Bella Cera Engineered Hardwood Flooring Installation Instructions Check for Proper Color Selection Prior to Installation 1 Important Information before You Begin 1.1 Installer/Owner Responsibility Carefully
More information4.3.5 - Breakaway Walls
4.3.5 - Breakaway Walls Elevation of a structure on a properly designed foundation reduces the potential for water damage from flooding. When the space below the lowest elevated floor is maintained free
More informationAttached/Detached Patio Cover/Carport
CITY OF MANTECA COMMUNITY DEVELOPMENT DEPARTMENT 1001 West Center Street Manteca, CA 95337 FAX (209) 923-8955 Building Safety Division (209) 456-8550 Community Development/Planning Division (209) 456-8500
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.
ICC-ES Evaluation Report ESR-90 Reissued December, 2009 This report is subject to re-examination in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
More informationGYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)
More informationNCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
More informationGYPSUM BOARD AND PLASTER
CHAPTER 25 GYPSUM BOARD AND PLASTER SECTION 2501 GENERAL 2501.1 Scope. 2501.1.1 General. Provisions of this chapter shall govern the materials, design, construction and quality of gypsum board, lath, gypsum
More informationPerformance by Design TM
Performance by Design TM OSB IN WOOD FRAME CONSTRUCTION U.S. EDITION 2005 OSB Performance by Design TM Oriented Strand Board in Wood Frame Construction U.S. Edition 2005 ABOUT THIS MANUAL This Manual has
More informationFlame Spread Performance of Wood Products
Flame Spread Performance of Wood Products Wood and wood-based products are widely used in interior wall, ceiling, and floor surfaces in all types of buildings. Appearance, acoustical qualities, and interior
More informationCITY OF LOS ANGELES CALIFORNIA
BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI
More informationHow to Install Hardwood Flooring Over a Sub Floor
How to Install Hardwood Flooring Over a Sub Floor Installation Preparation Instructions Read the entire instructions before starting your project. 1) INSPECT EACH PLANK (see fig. a) Wood is a natural product
More informationOriginally published in Western Roofing, May/June 1990.
Originally published in Western Roofing, May/June 1990. OSB vs. Plywood Comparison of Fastener Withdrawal Strengths on Wood Decks by Raymond W. LaTona, PhD, PE, and Sergio J. Zilli, PE, Simpson Gumpertz
More informationHardwood Flooring. Urbania Flooring
Engineered Hardwood Flooring Installation Guide for Urbania Flooring BEFORE STARTING THE INSTALATION - Please take the time to read and ensure that you understand the information contained in this document.
More informationBuilding Systems by Stora Enso. Residential multi-storey buildings
Building Systems by Stora Enso Residential multi-storey buildings Table of contents 1 Introduction and disclaimer... 3 1.1 Introduction... 4 1.2 The benefits of the system... 5 1.3 Disclaimer... 5 2 Anatomy
More informationSTRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
More informationCONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
More informationMezzanine. Technical manual
TechNICAL MANUAL 1 Mezzanine Technical manual 2 Varnished (optional) Product class P6 Melamined (optional) Tongue and groove Structural applications STANDARD FEATURE additional options - Chipboard - Varnished
More information8/18/14. Introduction to. Framing. Terminology and Concepts
8/18/14 Introduction to Framing Terminology and Concepts Terminology: Framing Level Two points on exactly the same horizontal plane. Square Intersecting lines or faces that form an exact 90 angle. Plumb
More informationRoof Deck Installation Guidelines
Roof Deck Installation Guidelines June 2012 TABLE OF CONTENTS INTRODUCTION GENERAL INFORMATION BEFORE THE DECK ARRIVES WHEN THE DECK ARRIVES CARE OF MATERIALS CAUTIONS INSTALLATION GENERAL TECTUM I PLANK
More informationGlulam Appearance Classifications for Construction Applications
T E C H N I C A L N O T E Glulam Appearance Classifications for Construction Applications Number Y110C July 2010 This Technical Note clarifies the distinction between appearance considerations and structural
More informationDesign Approach: 3) Full Sawn: In this case a rough surface is obtained with actual size equal to the nominal size.
E 479 Introduction: Sizes of Structural Lumer and Use Text hapter 4 Design Approach: The design of structural wood is carried on the asis of allowale stresses at service load levels. Structural calculations
More informationTimber Frame Construction
Timber Frame Construction Introduction Design and Detailing What is timber? Failure modes History of timber frame construction Forms of timber frame construction Live and dead loads Wind loads Roof construction
More informationLIGHT FLOOR AND WALL FRAMING
CHAPTER 1 LIGHT FLOOR AND WALL FRAMING In the normal sequence of construction events, the floor and wall activities follow the completed foundation work. In this chapter, we ll examine established methods
More informationAfter reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
More informationNORDIC ENGINEERED WOOD RESIDENTIAL DESIGN CONSTRUCTION GUIDE NORDIC JOISTTM FSC-CERTIFIED PRODUCTS AVAILABLE
NORDIC ENGINEERED WOOD RESIDENTIAL DESIGN CONSTRUCTION GUIDE NORDIC TM FSC-CERTIFIED PRODUCTS AVAILABLE BRINGING NATURE S RESOURCES HOME Nordic Engineered Wood was founded in the year 2000 to develop and
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationCOMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
More informationDiscipline: Structural Issued 04-26-06
California Department of General Services. Division of the State Architect. Product Acceptance Report STRUCTURAL SHEAR PANEL SURE-BOARD SERIES 200 PANELS PA-132 Discipline: Structural Issued 04-26-06 This
More informationEnvelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
More informationPatio Covers / Carports
Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
More informationWood Projects Outdoors. Post Hole Specifications. Deck Span Tables. www.jon Eakes.com
Wood Projects Outdoors Post Hole Specifications & Deck Span Tables www.jon Eakes.com Building Fences The depth of the fence posts into the ground must be at least one foot below the frost level for your
More informationHow to secure your property after a disaster
How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,
More informationH-Stud Area Separation Wall System
12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic
More information4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.
GENERAL CODE REQUIREMENTS (BASEMENTS) 1. FOOTINGS a. Footings shall be below frost line depth (42"). b. For an 8" foundation wall, footings shall be no less than 8" deep and 16" wide. c. Steel reinforcement
More informationChapter 10 - Scaffolding Systems
Chapter 10 - Scaffolding Systems Contents Chapter 10 - Scaffolding Systems... 10-1 Check and Oil the Pump Jacks... 10-4 Set Pump Jack Brackets... Error! Bookmark not defined. Set Pump Jack Poles... 10-5
More informationCHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
More informationHandling, Erection and Bracing of Wood Trusses
Handling, Erection and Bracing of Wood Trusses Follow these guidelines for safe installation of Wood Trusses. These guidelines should not be considered to be the only method for erecting and bracing of
More informationCode of Standard Practice for Timber Frame Structures
TFEC 2-2013 Code of Standard Practice for Timber Frame Structures August 2013 Preface This Code is intended to represent a reasonable consensus of what constitutes ordinary and acceptable practice within
More informationINSTALLATION IMPORTANT INSTALLER/OWNER RESPONSIBILITY TOOLS & EQUIPMENT NEEDED FOR INSTALLATION PRE-INSTALLATION PROCEDURES & JOBSITE CONDITIONS
IMPORTANT It is important that you read & understand the following information and instructions in their entirety before proceeding with installation. Please thoroughly inspect all Flooring products in
More informationGuide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses
Technical Guide Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses ASSESSMENT OF DAMAGE Prior to any assessments or repairs being commenced, a licensed electrician must undertake
More informationCity of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More information