Product Overview CHAPTER
|
|
- Magdalen Atkins
- 7 years ago
- Views:
Transcription
1 CHAPTER 1 This chapter describes the Catalyst 6000 family switches and contains these sections: Catalyst 6006 and Catalyst 6506 Switches, page 1-3 Catalyst 6009 and Catalyst 6509 Switches, page 1-5 Catalyst 6509-NEB Switch, page 1-9 Catalyst 6513 Switch, page 1-12 System Features, page 1-15 Switch Components, page
2 Chapter 1 These high-performance, modular, frame-based switches support high-density Fast Ethernet and Gigabit Ethernet in both campus-backbone and server-aggregation environments. The Catalyst 6006 and the Catalyst 6009 switches have a 32-Gbps switching capacity, while the Catalyst 6506, the Catalyst 6509, the Catalyst 6509-NEB, and the Catalyst 6513 switches support a backplane architecture that scales from 32 Gbps to 256 Gbps. With certain exceptions, all platforms share the same supervisor engines, switching modules, and software, and all support redundant configurations of supervisor engines, power supplies, and port interfaces. Exceptions are noted in the text. Typically, the Catalyst 6000 family Ethernet interfaces connect workstations and repeaters, while the Fast Ethernet interfaces connect workstations, servers, switches, and routers. The Gigabit Ethernet switching module provides a high-performance gigabit switching backbone, while the supervisor engine gigabit interfaces serve as uplinks that aggregate traffic from high-density 10/100-Mbps wiring closets. ATM LAN Emulation (LANE) and Multiprotocol over ATM (MPOA) support is provided by the ATM dual PHY OC-12 LANE/MPOA module. Throughout this publication, except where noted, the term supervisor engine is used to refer to both Supervisor Engine 1 and Supervisor Engine
3 Catalyst 6006 and Catalyst 6506 Switches Chapter 1 The Catalyst 6006 and Catalyst 6506 switches support the following: A supervisor engine with two Gigabit Ethernet uplink ports and an optional redundant supervisor engine The uplink ports are fully functional on the redundant supervisor engine in standby mode. Both supervisor engines in a single chassis must be completely identical. You can configure the redundant supervisor engines in a Catalyst 6000 family switch in one of three configurations: Two supervisor engines, each with no Multilayer Switch Feature Card (MSFC) and no Policy Feature Card (PFC) Two supervisor engines, each configured with a PFC daughter card Two supervisor engines, each configured with both an MSFC and a PFC daughter card Up to five additional switching modules (Ethernet, Fast Ethernet, Gigabit Ethernet, 10 Gigabit Ethernet, and ATM) in any combination Fabric-enabled module support provided in all slots (requires Switch Fabric Module) (Catalyst 6506 switch only) Hot-swappable fan assembly and modules Redundant AC-input or DC-input power supplies Backplane bandwidth of 32 Gbps (Catalyst 6006 switch) or scalable up to 256 Gbps (Catalyst 6506 switch) Backplane bandwidth greater than 32 Gbps requires that you install a Switch Fabric Module in the Catalyst 6506 switch chassis. 1-4
4 Chapter 1 Catalyst 6009 and Catalyst 6509 Switches A Switch Fabric Module (WS-C6500-SFM or WS-X6500-SFM2) (Catalyst 6506 switch only) The Switch Fabric Module requires Supervisor Engine 2. You must install the Switch Fabric Module in either slot 5 or slot 6 of the Catalyst 6506 switch. For redundancy, you can install a standby Switch Fabric Module. The module first installed functions as the primary module. When you install two Switch Fabric Modules at the same time, the module in slot 5 acts as the primary module, and the module in slot 6 acts as the backup. If you reset the module in slot 5, the module in slot 6 becomes the primary module. Mixing an SFM (WS-C6500-SFM) with an SFM2 (WS-X6500-SFM2) in the same Catalyst 6506, Catalyst 6509, or Catalyst 6509-NEB chassis is supported. Catalyst 6009 and Catalyst 6509 Switches The Catalyst 6009 and Catalyst 6509 switch chassis have nine slots each. (See Figure 1-2.) Slot 1 is reserved for the supervisor engine, which provides switching, local and remote management, and multiple gigabit uplink interfaces. Slot 2 can contain an additional supervisor engine, which can act as a backup if the first supervisor engine fails. If a redundant supervisor engine is not required, slot 2 is available for a switching module. For a detailed description of supervisor engine operation in a redundant configuration, refer to the Catalyst 6000 Family Software Configuration Guide. 1-5
5 Catalyst 6009 and Catalyst 6509 Switches Chapter 1 The Catalyst 6009 and Catalyst 6509 switches support the following: A supervisor engine with two Gigabit Ethernet uplink ports and an optional redundant supervisor engine The uplink ports are fully functional on the redundant supervisor engine in standby mode. Both supervisor engines in a single chassis must be completely identical. You can configure the redundant supervisor engines in a Catalyst 6000 family switch in one of three configurations: Two supervisor engines, each with no MSFC and no PFC Two supervisor engines, each configured with a PFC daughter card Two supervisor engines, each configured with both an MSFC and a PFC daughter card Backplane bandwidth of 32 Gbps (Catalyst 6009 switch) or scalable up to 256 Gbps (Catalyst 6509 switch) Backplane bandwidth greater than 32 Gbps requires that you install a Switch Fabric Module in the Catalyst 6509 switch chassis. Up to eight additional switching modules (Ethernet, Fast Ethernet, Gigabit Ethernet, and ATM) Fabric-enabled module support provided in all slots (requires Switch Fabric Module) (Catalyst 6509 switch only) Hot-swappable fan assembly and modules Redundant AC-input or DC-input power supplies 1-6
6 Chapter 1 Catalyst 6009 and Catalyst 6509 Switches A Switch Fabric Module (WS-C5600-SFM or WS-X6500-SFM2) (Catalyst 6509 switch only) The Switch Fabric Module requires Supervisor Engine 2. You must install the Switch Fabric Module in either slot 5 or slot 6 of the Catalyst 6509 switch. For redundancy, you can install a standby Switch Fabric Module. The module first installed functions as the primary module. When you install two Switch Fabric Modules at the same time, the module in slot 5 acts as the primary module, and the module in slot 6 acts as the backup. If you reset the module in slot 5, the module in slot 6 becomes the primary module. Mixing an SFM (WS-C6500-SFM) with an SFM2 (WS-X6500-SFM2) in the same Catalyst 6506, Catalyst 6509, or Catalyst 6509-NEB chassis is supported. 1-7
7 Chapter 1 Catalyst 6509-NEB Switch Catalyst 6509-NEB Switch The Catalyst 6509-NEB switch chassis has nine vertical slots that are numbered from right to left. (See Figure 1-3.) Slot 1 is reserved for the supervisor engine, which provides switching, local and remote management, and multiple gigabit uplink interfaces. Slot 2 can contain an additional supervisor engine, which can act as a backup if the first supervisor engine fails. If a redundant supervisor engine is not required, slot 2 is available for a switching module. For a detailed description of supervisor engine operation in a redundant configuration, refer to the Catalyst 6000 Family Software Configuration Guide. The Catalyst 6509-NEB switch supports the following: A supervisor engine with two Gigabit Ethernet uplink ports and an optional redundant supervisor engine The uplink ports are fully functional on the redundant supervisor engine in standby mode. Both supervisor engines in a single chassis must be completely identical. You can configure the redundant supervisor engines in a Catalyst 6000 family switch in one of three configurations: Two supervisor engines, each with no MSFC and no PFC Two supervisor engines, each configured with a PFC daughter card Two supervisor engines, each configured with both an MSFC and a PFC daughter card Backplane bandwidth scalable up to 256 Gbps Backplane bandwidth greater than 32 Gbps requires that you install a Switch Fabric Module in the Catalyst 6509-NEB switch chassis. 1-9
8 Catalyst 6509-NEB Switch Chapter 1 A Switch Fabric Module (WS-C6500-SFM or WS-X6500-SFM2) The Switch Fabric Modules require Supervisor Engine 2. You must install the Switch Fabric Module in either slot 5 or slot 6 of the Catalyst 6509-NEB switch. For redundancy, you can install a standby Switch Fabric Module. The module first installed functions as the primary module. When you install two Switch Fabric Modules at the same time, the module in slot 5 acts as the primary module, and the module in slot 6 acts as the backup. If you reset the module in slot 5, the module in slot 6 becomes the primary module. Mixing an SFM (WS-C6500-SFM) with an SFM2 (WS-X6500-SFM2) in the same Catalyst 6506, Catalyst 6509, or Catalyst 6509-NEB chassis is supported. Up to eight additional switching modules (Ethernet, Fast Ethernet, Gigabit Ethernet, and ATM) Fabric-enabled module support provided in all slots (requires Switch Fabric Module) Hot-swappable fan assembly and modules Redundant AC-input or DC-input power supplies 1-10
9 Catalyst 6513 Switch Chapter 1 Catalyst 6513 Switch The Catalyst 6513 switch chassis has 13 slots. (See Figure 1-4.) Slot 1 is reserved for the supervisor engine, which provides switching, local and remote management, and multiple gigabit uplink interfaces. The Catalyst 6513 switch requires a Supervisor Engine 2. Slot 2 can contain an additional Supervisor Engine 2, which can act as a backup if the first supervisor engine fails. If a redundant supervisor engine is not required, slot 2 is available for a switching module. For a detailed description of supervisor engine operation in a redundant configuration, refer to the Catalyst 6000 Family Software Configuration Guide. The Catalyst 6513 switch supports the following: A Supervisor Engine 2 with two Gigabit Ethernet uplink ports and an optional redundant Supervisor Engine 2 The uplink ports are fully functional on the redundant Supervisor Engine 2 in standby mode. Both supervisor engines in a single chassis must be completely identical. You can configure the redundant supervisor engines in a Catalyst 6000 family switch in one of three configurations: Two supervisor engines, each with no MSFC and no PFC Two supervisor engines, each configured with a PFC daughter card Two supervisor engines, each configured with both an MSFC and a PFC daughter card Backplane bandwidth scalable up to 256 Gbps Backplane bandwidth greater than 32 Gbps requires that you install a Switch Fabric Module in the Catalyst 6513 switch chassis. 1-12
10 Chapter 1 Catalyst 6513 Switch A Switch Fabric Module (WS-X6500-SFM2 only) The Switch Fabric Module requires Supervisor Engine 2. You must install the Switch Fabric Module in slot 7 or slot 8 of the Catalyst 6513 switch. For redundancy, you can install a standby Switch Fabric Module. The module first installed functions as the primary module. When you install two Switch Fabric Modules at the same time, the module in slot 7 acts as the primary module, and the module in slot 8 acts as the backup. If you reset the module in slot 7, the module in slot 8 becomes the primary module. Up to 12 additional switching modules (Ethernet, Fast Ethernet, Gigabit Ethernet, and ATM) Fabric-enabled module support provided in all slots (requires Switch Fabric Module) Dual Fabric connectivity supported in slots 9 13 (requires Switch Fabric Module) Hot-swappable fan assembly and modules Redundant AC-input or DC-input power supplies 1-13
11 Chapter 1 System Features System Features This section describes the hardware features for the Catalyst 6000 family switches. For software descriptions, refer to the Catalyst 6000 Family Software Configuration Guide. For module descriptions and installation procedures, refer to the Catalyst 6000 Family Module Installation Guide. Bandwidth and Port Density Table 1-1 lists the bandwidth and port densities of the Catalyst 6000 family switches. Table 1-1 Catalyst 6000 Family Bandwidth and Port Density Architecture Catalyst 6000 Series Switch Catalyst 6500 Series Switch Backplane Bandwidth 32 Gbps 32 to 256 Gbps 1 Number of 10 Gigabit Ethernet Ports Number of Gigabit Ethernet Ports 2, 3 Number of 100BASE-FX Ethernet ports Number of 10/100 Ethernet Ports Number of 10BASE-FL Ethernet Ports 5 (6 slots) Catalyst 6006 switch 8 (9 slots) Catalyst 6009 switch 82 (6 slots) Catalyst 6006 switch 130 (9 slots) Catalyst 6009 switch 120 (6 slots) Catalyst 6006 switch 192 (9 slots) Catalyst 6009 switch 240 (6 slots) Catalyst 6006 switch 384 (9 slots) Catalyst 6009 switch 120 (6 slots) Catalyst 6006 switch 192 (9 slots) Catalyst 6009 switch 5 (6 slots) Catalyst 6506 switch 8 (9 slots) Catalyst 6509 switch 12 (13 slots) Catalyst 6513 switch 82 (6 slots) Catalyst 6506 switch 130 (9 slots) Catalyst 6509 switch 192 (13 slots) Catalyst 6513 switch 120 (6 slots) Catalyst 6506 switch 192 (9 slots) Catalyst 6509 switch 288 (13 slots) Catalyst 6513 switch 240 (6 slots) Catalyst 6506 switch 384 (9 slots) Catalyst 6509 switch 576 (13 slots) Catalyst 6513 switch 120 (6 slots) Catalyst 6506 switch 192 (9 slots) Catalyst 6509 switch 288 (13 slots) Catalyst 6513 switch 1-15
12 System Features Chapter 1 Table 1-1 Catalyst 6000 Family Bandwidth and Port Density (continued) Architecture Catalyst 6000 Series Switch Catalyst 6500 Series Switch Number of ATM OC-12 Ports Number of FlexWAN Modules 5 (6 slots) Catalyst 6006 switch 8 (9 slots) Catalyst 6009 switch 5 (6 slots) Catalyst 6006 switch 8 (9 slots) Catalyst 6009 switch 5 (6 slots) Catalyst 6506 switch 8 (9 slots) Catalyst 6509 switch 12 (13 slots) Catalyst 6513 switch 5 (6 slots) Catalyst 6506 switch 8 (9 slots) Catalyst 6509 switch 12 (13 slots) Catalyst 6513 switch 1. Backplane bandwidth greater than 32 Gbps requires that you install a Switch Fabric Module in the Catalyst 6500 Series switch chassis. 2. You can have a maximum of BASE-ZX GBICs per system to comply with EN55022 Class B. You can have a maximum of BASE-ZX GBICs (with plastic rails) per system or BASE-ZX GBICs (with metal rails) per system to comply with FCC Class A. 3. To comply with FCC Class A requirements, you can install up to 12 WS-G5483 GBICs in a Catalyst 6000 family switch chassis. Redundancy Catalyst 6000 family switches have these redundancy features: Ability to house two hot-swappable supervisor engines Ability to house two fully redundant, AC-input or DC-input, load-sharing power supplies In certain configurations, the power supplies are not fully redundant. Refer to the Power Supply Redundancy section on page A hot-swappable fan assembly containing multiple fans Redundant backplane-mounted clock modules Redundant backplane-mounted voltage termination (VTT) modules 1-16
13 Chapter 1 Switch Components Component Hot Swapping You can hot swap all modules (including the supervisor engine if you have a redundant supervisor engine) and the fan assembly. You can add, replace, or remove modules without interrupting the system power or causing other software or interfaces to shut down. Switch Components This section describes the major hardware components for the Catalyst 6000 family switches. Fan Assembly The system fan assembly provides cooling air for the supervisor engine and the switching modules. The fan assembly is located in the chassis. Figure 1-5 (Catalyst 6006 and 6506 switches), Figure 1-6 (Catalyst 6009 and 6509 switches), Figure 1-7 (Catalyst 6509-NEB switch), and Figure 1-8 (Catalyst 6513 switch) show the direction of airflow into and out of the switch. Sensors on the supervisor engine monitor the internal air temperatures. If the air temperature exceeds a preset threshold, the environmental monitor displays warning messages. We recommend that you maintain a minimum air space of 6 inches (15 cm) between walls and the chassis air vents and a minimum separation of 12 inches (30.5 cm) between two chassis to prevent overheating. If an individual fan within the assembly fails, the FAN STATUS LED turns red. Individual fans cannot be replaced. To replace a fan assembly, see the Removing and Replacing the Fan Assembly section on page Refer to the Catalyst 6000 Family Software Configuration Guide for information on environmental monitoring. 1-17
14 Switch Components Chapter 1 Catalyst 6000 family chassis power supply configurations are shown in Table 1-2. Table 1-2 Catalyst 6000 Family Power Supply Configurations Catalyst 6000 Family Switch Catalyst 6006/6506 Catalyst 6009/6509 Catalyst 6509-NEB Catalyst 6513 Power Supply Configurations 1000W AC-input 1300W AC- and DC-input 2500W AC- and DC-input 1300W AC- and DC-input 2500W AC- and DC-input 4000W AC-input 1300W AC- and DC-input 2500W AC- and DC-input 4000W AC-input 2500W AC- and DC-input 4000W AC-input Catalyst 6000 family switches support redundant AC-input and DC-input power supplies. Unlike the Catalyst 4000 family and Catalyst 5000 family switches, the Catalyst 6000 family switches allow you to mix AC-input and DC-input power supplies in the same chassis. Many telco organizations require a 48 VDC power supply to accommodate their power distribution systems. From an operational perspective, the DC-input power supply has the same characteristics as the AC-input version. The AC-input power supply (see Figure 1-9) has a detachable power cord (except for the WS-CAC-4000W) that allows you to connect each power supply to the site power source. You can connect the DC-input power supply (see Figure 1-10) to the power source with heavy gauge wiring connected to a terminal block. The wire gauge size is determined by local electrical codes and restrictions. The power cord is not shown in Figure
15 Chapter 1 Switch Components With redundancy enabled, if you power up the system with two power supplies of unequal wattage, both power supplies come online but a syslog message displays that the lower wattage power supply will be disabled. If the active power supply fails, the lower wattage power supply that was disabled comes online and, if necessary, selectively powers down certain modules so that the capacity of the remaining power supply is not exceeded. In a nonredundant configuration, the power available to the system is the combined power capability of both power supplies. The system powers up as many modules as the combined capacity allows. However, if one supply should fail and there is not enough power for all previously powered up modules, the system powers down some modules. You can change the configuration of the power supplies to redundant or nonredundant at any time. If you switch from a redundant to a nonredundant configuration, both power supplies are enabled (even a power supply that was disabled because it was of a lower wattage than the other power supply). If you change from a nonredundant to a redundant configuration, both power supplies are initially enabled, and if they are of the same wattage, remain enabled. If they are of different wattage, a syslog message displays and the lower wattage supply is disabled. For additional information about the power management feature and individual module power consumption, refer to the Catalyst 6000 Family Software Configuration Guide. Environmental Monitoring of the Power Supply The environmental monitoring and reporting functions allow you to maintain normal system operation by resolving adverse environmental conditions prior to loss of operation. The power supplies monitor their own internal temperature and voltages. In the event of excessive internal temperature, the power supply will shut down to prevent damage. When the power supply returns to a safe operating temperature, it will restart. In the event of an abnormal voltage on one or more outputs of the power supplies, the OUTPUT FAIL LED will light. Substantial overvoltage conditions can lead to a power supply shutdown. The power supply front panel LEDs are described in Table 1-3. For more information about the environmental monitoring feature, refer to the Catalyst 6000 Family Software Configuration Guide. 1-25
16 Switch Components Chapter 1 Table 1-3 Power Supply Front Panel LEDs LED INPUT OK FAN OK OUTPUT FAIL Description AC-input power supplies: Green when the input voltage is OK (85 VAC or greater) Off when the input voltage falls below 70 VAC or if the power supply shuts down DC-input power supplies: Green when the input voltage is OK ( 40.5 VDC or greater) Off when the input voltage falls below 33 VDC or if the power supply shuts down Green when the power supply fan is operating properly Red when there is a problem with one or more of the DC-output voltages of the power supply Power Supply Fan Assembly The power supplies have a built-in fan; air enters the front of the fan (power-input end) and exits through the back. An air dam keeps the airflow separate from the rest of the chassis, which is cooled by the system fan assembly. Power supply fans are not field-replaceable; the power supply must be replaced. To replace a power supply, see the Removing and Replacing the Power Supply section on page
Environmental Monitoring
CHAPTER 13 Overview, page 13-1 How to Determine Sensor Temperature Thresholds, page 13-2 How to Monitor the System Environmental Status, page 13-3 Information About LED Environmental Indications, page
More informationEnhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge
Enhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge Cisco 7609-S Router The Cisco 7609-S Router is a high-performance router deployed at the network edge, where performance,
More informationExtending Performance, Versatility, and Reliability at the Provider Edge
Cisco 7606 Chassis Extending Performance, Versatility, and Reliability at the Provider Edge Cisco 7606 Router The Cisco 7606 Router is a compact, high-performance router designed in a 6-slot form factor
More informationEnhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge
Cisco 7606-S Router Enhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge The Cisco 7606-S Router is a compact, high-performance router designed in a 6-slot form factor
More informationExtending Performance, Versatility, and Reliability at the Provider Edge
Cisco 7604 Chassis Extending Performance, Versatility, and Reliability at the Provider Edge Cisco 7604 Router The Cisco 7604 Router is a compact, high-performance router designed in a 4-slot form factor
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationPower Supply Specifications
APPENDIXA This appendix describes the Catalyst 6500 series power supplies and provides their specifications. This appendix contains the following sections: Power Supply Compatibility Matrix, page A-2 950
More informationHow To Build A Cisco Uniden Computing System
Data Sheet Cisco UCS 5100 Series Blade Server Chassis Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites computing,
More informationCisco Nexus 7000 Series Power Supply Modules
Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable
More informationEnterprise Switches. Accelar 8000
Enterprise Switches Accelar 8000 10-slot and 6-slot Chassis Data Sheet High Availability Operational Simplicity Low cost of Ownership Year 2000 Compliant The Accelar 8000 enterprise switch is a new platform
More informationUsing a Fabric Extender with a Cisco Nexus 5000 Series Switch
CHAPTER Using a Fabric Extender with a Cisco Nexus 5000 Series Switch This chapter describes the Cisco Nexus 000 Series Fabric Extenders (FEXs) and includes these sections: Information About, page - Cisco
More informationChassis, Power Supply, and Element Management
Chassis, Power Supply, and Element Management C-COR CHP Max5000 Converged Headend Platform Accelerate deployment of new, revenue generating advanced services Innovative technology creating converged high-
More information100 240VAC 50/60Hz Power Adapter
DGS-1224T D-Link 24-Port 10/100/1000Mbps + 2 Combo Mini GBIC Gigabit Smart Switch Broadband Router Before Your Begin This Quick Installation Guide gives step-by-step instructions for setting up the D -Link
More informationDSX-HSCS Hot Swap Comm Server
DSX Access Systems, Inc. DSX-HSCS Hot Swap Comm Server WinDSX Hot Swap Redundancy Software Hot-Swap Redundant Communications Server provides continued availability of System Communications and Control
More informationI STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
More informationCisco Catalyst 6500 Series Switch
Data Sheet Cisco Catalyst 6500 Series Switch The Catalyst 6500 Series sets the new standard for IP communications and application delivery in enterprise campus and service provider networks by maximizing
More informationCisco Nexus 7000 Series.
Data Sheet Cisco Nexus 7000 Series Chassis Product Overview The Cisco Nexus 7000 Series Switches combine the highest levels of scalability with operational flexibility. The Cisco Nexus 7000 Series Switches
More informationCisco IOS Server Load Balancing and the Catalyst 6000 Family of Switches
WHITE PAPER Cisco IOS Server Load Balancing and the Catalyst 6000 Family of Switches The Catalyst 6000 family, which includes the Catalyst 6500 and the Catalyst 6000 series, delivers high-performance,
More informationChapter 10 Troubleshooting
Chapter 10 Troubleshooting This chapter explains how you can troubleshoot a specific problem, such as abnormal LED activity or no system power, when you power up the router. Topic Page Diagnosing Problems
More informationWANic 800 & 805. 1 or 2 HSSI ports Up to 52 Mbps/port. WANic 850 & 855. 1 or 2 T3 or E3 ports Full-speed CSU/DSU. WANic 880.
WANic P C I S O L U T I O N S WANic PCI cards are high-performance synchronous WAN adapters for use in standard Linux PCs and Industrial Series routers from ImageStream. WANic adapters include one, two,
More informationMcAfee Data Loss Prevention
Hardware Guide Revision B McAfee Data Loss Prevention 1650, 3650, 4400, 5500 This guide describes the features and capabilities of McAfee Data Loss Prevention (McAfee DLP) appliances to help you to manage
More informationSummitStack in the Data Center
SummitStack in the Data Center Abstract: This white paper describes the challenges in the virtualized server environment and the solution Extreme Networks offers a highly virtualized, centrally manageable
More informationCisco Nexus 7000 Series Supervisor Module
Cisco Nexus 7000 Series Supervisor Module The Cisco Nexus 7000 Series Supervisor Module (Figure 1) scales the control plane and data plane services for the Cisco Nexus 7000 Series system in scalable data
More informationCatalyst 6500 Series Quick Look
Overview Quick Look High-performance, multilayer switches optimized the most demanding Enterprise and Service Provider applications. The Catalyst 6500 series is the foundation for secure converged network
More informationSummitStack in the Data Center
SummitStack in the Data Center Abstract: This white paper describes the challenges in the virtualized server environment and the solution that Extreme Networks offers a highly virtualized, centrally manageable
More informationServer Consolidation and Remote Disaster Recovery: The Path to Lower TCO and Higher Reliability
Server Consolidation and Remote Disaster Recovery: The Path to Lower TCO and Higher Reliability Executive Summary: To minimize TCO for server / data center consolidation and optimize disaster recovery
More informationCisco Communication Media Module
Cisco Catalyst 6500 Series and Cisco 7600 Series Communication Media Module Product Overview Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility
More informationCisco 7400 Series Internet Router
Cisco 7400 Series Internet Router Product Overview The Cisco 7400 Internet Router is the highest performance single-rack unit (1RU) service-rich router in the industry. Its compact, stackable architecture
More informationCisco TelePresence MSE 8000
Cisco TelePresence MSE 8000 Figure 1. Cisco TelePresence MSE 8000 The Cisco TelePresence portfolio creates an immersive, face-to-face experience over the network empowering you to collaborate with others
More informationCisco Redundant Power System 2300
Cisco Redundant Power System 2300 The Cisco Redundant Power System 2300 (RPS 2300) increases availability for converged data, voice, and video networks. The system delivers power supply redundancy and
More informationFASTIRON II SWITCHES Foundry Networks award winning FastIron II family of switches provides high-density
Delivers Industry Leading Price, Performance and Flexibility to Wiring Closets, Desktops and Server Farms Provides High-density 10/100 Mbps Ethernet and Gigabit Ethernet Copper Connectivity to Workstations
More informationSolutions Guide. High Availability IPv6
Solutions Guide High Availability IPv6 Introduction The Internet has forever changed contemporary society, with online access an integral part of our 21st century lifestyles. Finding out what movie is
More informationHFE1600 Series 1600W 1U Hot Swap Front End Power Supplies
25.2W/in 3 power density Internal ORing MOSFET & Current Share Climate Savers Computing efficiency standards Up to 8000W in 1U rack Single and dual output 1U racks PMBus option HFE1600 Series 1600W 1U
More informationHUAWEI Tecal E6000 Blade Server
HUAWEI Tecal E6000 Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The HUAWEI Tecal E6000 is a new-generation server platform that guarantees comprehensive and powerful
More information8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual
8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch User Manual Part#: PL-1008G V0613 Package Contents: The following items should be found in your package: 8 Port Desk-top Giga Ethernet Switch Power Adapter
More informationCisco Catalyst 6500 and 6500-E Series Switch
Cisco Catalyst 6500 and 6500-E Series Switch Product Overview The Cisco Catalyst 6500 and 6500-E Series sets the new standard for IP Communications and application delivery in enterprise campus and service
More informationIP DSLAM IDL-2402. Quick Installation Guide
IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...
More informationIndustrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
More information8-Port E3/DS3 ATM Line Card Overview
CHAPTER 8-Port E/DS ATM Line Card Overview This chapter describes the Cisco series 8-port E/DS ATM line card (referred to as the 8-port E/DS ATM line card) and contains the following sections: Line Card
More informationThe On-Demand Application Delivery Controller
What s Inside: 2 Increase Intelligence, Not Operating Costs 2 Simplify Your Network 2 Maximize Large-Scale Application Performance 2 Achieve Ultimate Reliability 2 The Advantages of Technology 6 Platforms
More informationEAGLE Power over Ethernet Products for IP Powering Applications. Flexibility, Simplicity and Value LAN POWER SYSTEMS. Trend Datacom USA, Inc.
EAGLE Power over Ethernet Products for IP Powering Applications Flexibility, Simplicity and Value LAN POWER SYSTEMS Trend Datacom USA, Inc. Presentation Agenda IEEE802.3af PoE Technology Definitions and
More informationModel #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
More informationCisco Nexus 7000 Series
Data Sheet Cisco Nexus 7000 Series Switches Product Overview Cisco Nexus 7000 Series Switches combine high levels of scalability with operational flexibility. Cisco Nexus 7000 Series Switches provide the
More informationPC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power
More informationStorageBox 1000. High Performance NVMe JBOF
High Performance NVMe JBOF The High Capacity, Fastest and Most Modular Direct Attached NVMe Storage Device for VDI and HPC BLAZING 12GB/s SPEED 8 DRIVES [1U ] WORKS WITH ANY SERVER The Magma StorageBox
More informationNetwork Analysis Modules
CHAPTER 6 This chapter describes the (NAMs) and contains the following sections: Network Analysis Module (WS-SVC-NAM-1), page 6-2 Network Analysis Module (WS-SVC-NAM-2), page 6-4 NAMs monitor and analyze
More informationCisco CRS 4-Slot Line Card Chassis Overview
CHAPTER 1 This chapter describes the Cisco CRS Carrier Routing System 4-Slot Line Card Chassis and its main components. The following sections are included: System Overview, page 1-2 Main Features of the
More informationUser Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual
ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) User Manual Table of Contents 1 Introduction 2 General specification 3 Installation 4 Pin assignment & function of connectors 5 Drawing
More informationGigabit to the edge. HP ProCurve Networking Solutions
Gigabit to the edge HP ProCurve Networking Solutions Performance to the edge taking high-speed Gigabit to the edge of your network When it comes to your network, the faster you want something, the slower
More informationDeliver More Applications for More Users
HARDWARE DATASHEET Deliver More Applications for More Users F5 BIG-IP Application Delivery Controller (ADC) platforms can manage even the heaviest traffic loads at both layer 4 and layer 7. By merging
More informationCatalyst 2900 Series XL Autosensing Fast Ethernet Switches
Catalyst 2900 Series XL Autosensing Fast Ethernet Switches Product Overview Cisco s Catalyst 2900 Series XL is a full line of 10/100 autosensing Fast Ethernet switches from the leader in networking that
More informationCisco TelePresence MSE 8000
Cisco TelePresence MSE 8000 Figure 1. Cisco TelePresence MSE 8000 Product Overview The Cisco TelePresence MSE 8000 (MSE 8000) is a high-capacity voice and video conferencing media services engine. This
More informationSmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
More informationEonStor DS High-Density Storage: Key Design Features and Hybrid Connectivity Benefits
EonStor DS High-Density Storage: Key Design Features and Hybrid Connectivity Benefits White Paper Abstract This white paper introduces the key design features and hybrid FC/iSCSI connectivity benefits
More informationQuick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
More information8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide
8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
More informationTAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line
More informationHow To Buy An Fujitsu Primergy Bx400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server BLADE MADE EASY - tailor-made for medium-sized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well
More informationCisco 3600 Series Multiservice Platforms
CN/LP RXC 3 2 1 0 1 0 Cisco 3600 Series Multiservice Platforms Product Overview The Cisco 3600 series is a multifunction platform that combines dial access, routing, and LAN-to-LAN services and multiservice
More informationSmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
More informationCISCO 7609 ROUTER ENHANCED 9-SLOT CHASSIS
DATA SHEET CISCO 7609 ROUTER ENHANCED 9-SLOT CHASSIS The Cisco 7609 Router is a high-performance router deployed at the network edge, where performance, IP services, redundancy, and fault resiliency are
More informationCisco Catalyst 4000/4500 Series Gigabit Ethernet Modules
Data Sheet Cisco Catalyst 4000/4500 Series Gigabit Ethernet Modules Overview The Cisco Catalyst 4000/4500 series of scalable, modular, high-density, switches deliver high performance, integrated Layer
More informationUsing Industrial Ethernet Switches to Assure Maximum Uptime White Paper
Six Best Practices for Effective Wind Farm Operation Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper Six Best Practices for Effective Wind Farm Operation Using Industrial Ethernet
More informationSetting Up and Testing the MAX Hardware
Page 1 of 12 Setting Up and Testing the MAX Hardware This chapter covers these topics: Planning the hardware installation Inserting an expansion card Setting up the hardware Connecting to input power Connecting
More informationProCurve Switch 8000m (J4110A) and Switch 8000m
ProCurve Switch 4000m and Switch 8000m The ProCurve Switch 4000m and 8000m are managed modular 10/100/1000 desktop switches that provide scalable, expandable, low-cost migration to 10/100 switching for
More informationEmerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
More informationCisco ASR 9001-S Router
Data Sheet Cisco ASR 9001-S Router Product Overview Part of the Cisco ASR 9000 Series, the Cisco ASR 9001-S Router (Figure 1) is a compact, high-capacity provider edge router that delivers 60 Gbps of nonblocking,
More informationChapter 1 Reading Organizer
Chapter 1 Reading Organizer After completion of this chapter, you should be able to: Describe convergence of data, voice and video in the context of switched networks Describe a switched network in a small
More informationWatchdog Monitor user guide
General The Watchdog AW-4, in short AW-4, can be controlled and monitored by a centralized monitor server. This server is located in a large Dutch server centre with high speed connections, directly connected
More informationDORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
More informationModel #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V
SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationHow To Power And Cool A Data Center
Architecting the Green Data Center Viktor Hagen Field Business Development Data Center & High Performance Computing 1 Where we are Today Environmental sustainability is a major global trend for the 21st
More informationVersalar Switch Router 15000. Market Opportunity and Product Overview
Versalar Switch Router 15000 Market Opportunity and Product Overview Services Driven Market Value-added services ($15B) e-commerce, IP Telephony, IP Fax, Security services, VPN, customer care, flexible
More informationHardware Manual Product Model: DAS-3626 VDSL2 Switch Release 1.00
Hardware Manual Product Model: DAS-3626 VDSL2 Switch Release 1.00 Copyright 2009. All rights reserved Information in this document is subject to change without notice. 2009 D-Link Corporation. All rights
More informationIxia xstream TM 10. Aggregation, Filtering, and Load Balancing for qgbe/10gbe Networks. Aggregation and Filtering DATA SHEET
Ixia xstream TM 10 Aggregation, Filtering, and Load Balancing for qgbe/10gbe Networks The Ixia xstream 10 is a network packet broker for monitoring high-speed network traffic, letting you share the network
More informationData Sheet Fujitsu PRIMERGY BX400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost way to build and run an IT infrastructure in your midsize organization,
More informationOPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL
OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-NMS Rev. X1 E-Mail: salessupport@olsontech.com www.olsontech.com
More informationHow to Set Up Your NSM4000 Appliance
How to Set Up Your NSM4000 Appliance Juniper Networks NSM4000 is an appliance version of Network and Security Manager (NSM), a software application that centralizes control and management of your Juniper
More informationData Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions
Data Centers Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions 1 Introduction The growing speed and footprint of data centers is challenging
More information30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
More informationSmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine
More informationCisco 7200 Series. Product Overview. Key Features and Benefits
Cisco 7 Series Product Overview Cisco 7 series routers are designed for today s most mission-critical internetworks because they combine Cisco Systems proven software technology with reliability, availability,
More informationArista and Leviton Technology in the Data Center
Visit: www.leviton.com/aristanetworks Arista and Leviton Technology in the Data Center Customer Support: 1-408-547-5502 1-866-476-0000 Product Inquiries: 1-408-547-5501 1-866-497-0000 General Inquiries:
More informationSmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,
More informationSmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,
More informationCatalyst 6000 and 6500 Series Architecture
WHITE PAPER Catalyst 6000 and 6500 Series Architecture Executive Summary The ever-increasing demands for bandwidth and performance, and even greater need for intelligent network services, challenge today
More informationIndustrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
More informationProvides one channel for Ethernet over existing
LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information
More informationCisco IOS Software Release 12.2(31)SGA for Cisco Catalyst 4500 Series Supervisor Engines
Product Bulletin No. 364872 Cisco IOS Software Release 12.2(31)SGA for Cisco Catalyst 4500 Series Engines This product bulletin describes the hardware and software features supported by Cisco IOS Software
More informationSeagate Business Storage 8-bay Rackmount NAS Reviewer s Guide
Seagate Business Storage 8-bay Rackmount NAS Reviewer s Guide Seagate Business Storage 8-bay Rackmount NAS Reviewer s Guide/page 2 Purpose of this guide Experience the most common use cases for the product,
More informationData Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise
More informationPractical Power Guidelines for Cisco VoIP and Internet Telephony Applications
www.tripplite.com Practical Power Guidelines for Cisco VoIP and Internet Telephony Applications by David Slotten Tripp Lite is a Cisco Technology Developer Partner in the Cisco Technology Developer Program.
More informationMcAfee Firewall Enterprise
Hardware Guide Revision C McAfee Firewall Enterprise S1104, S2008, S3008 The McAfee Firewall Enterprise Hardware Product Guide describes the features and capabilities of appliance models S1104, S2008,
More informationScalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs
Protecting the Data That Drives Business SecureSphere Appliances Scalable. Reliable. Flexible. Imperva SecureSphere appliances provide superior performance and resiliency for demanding network environments.
More informationScalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs
Protecting the Data That Drives Business SecureSphere Appliances Scalable. Reliable. Flexible. Imperva SecureSphere appliances provide superior performance and resiliency for demanding network environments.
More informationUser Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
More informationRC8021 Indoor Camera Installation Guide
RC8021 Indoor Camera Installation Guide P/N: 957YL502GJ Document Version: 1.0 Copyright 2011. All Rights Reserved. All trademarks and trade names are the properties of their respective owners i Package
More informationCisco TelePresence MSE 8000
Data Sheet Cisco TelePresence MSE 8000 Figure 1. Cisco TelePresence MSE 8000 Product Overview The Cisco TelePresence MSE 8000 (MSE 8000) is a high-capacity voice and video conferencing media services engine.
More informationBristol ControlWave Redundant Control
October 19, 2007 - Page 1 Bristol ControlWave Redundant Control Redundant systems are offered for critical processes and harsh applications that require maximum operational readiness and system availability.
More information