PROFINET/Industrial Ethernet Industrial PC Rack PC

Size: px
Start display at page:

Download "PROFINET/Industrial Ethernet Industrial PC Rack PC"

Transcription

1 Industrial PC Rack PC SIMATIC IPC547D Ordering data Article No. Article No. SIMATIC IPC547D 3) 6AG Interfaces: x Gbit Ethernet (RJ45), 1 x DisplayPort, 1 x DVI-I, 8 x USB on the rear, x USB on the front, 1 x USB internal, 1 x serial (COM1), x PS/, audio; 7 slots (all long): 4 x PCI, 1 x PCIe x16, 1 x PCIe x16 (4 lanes), 1 x PCIe x8 (1 lane); mounting locations: 6 (3 x 5.5", 1 x 3.5" externally accessible; x 3.5" internal); temperature and fan monitoring; watchdog; card retainer Processors Pentium Dual Core G850 (C/T,.90 GHz, 3 MB Last Level Cache, EM64T, VT) Core i5-400 (4C/4T, 3.10 GHz, 6 MB Last Level Cache, Turbo Boost.0, EM64T, VT-x/-d, iamt) Core i7-600 (4C/8T, 3.40 GHz, 8 MB Last Level Cache, Turbo Boost.0, EM64T, VT-x/-d, iamt) Drives 500 GB HDD SATA; internal 1 TB HDD SATA; internal RAID1, 1 TB ( x 1 TB HDD SATA, mirror disks); internal 1) 50 GB solid-state drive (SLC) SATA; internal 500 GB HDD SATA in removable drive bay; front x 500 GB HDD SATA in removable drive bay; front RAID1, 1 TB ( x 1 TB HDD SATA, mirror disks) in removable drive bay; for hot swapping; at the front RAID5, TB (3 x 1 TB HDD SATA, striping with parity) in removable drive bay; for hot swapping; at the front 50 GB solid-state drive (SLC) SATA in removable drive bay; at the front RAID1, 1 TB ( x 1 TB HDD SATA, mirror disks) in removable drive bay; hot swapping; at the front + 50 GB solid-state drive (SLC) SATA in removable drive bay; at the front (operating system installed on SSD, if configured) Memory configuration 1 GB DDR3 SDRAM (1 x 1 GB), single channel GB DDR3 SDRAM ( x 1 GB), dual channel 4 GB DDR3 SDRAM ( x GB), dual channel 8 GB DDR3 SDRAM ) ( x 4 GB), dual channel 16 GB DDR3 SDRAM ) (4 x 4 GB), dual channel 3 GB DDR3 SDRAM ) (4 x 8 GB), dual channel A C D A B D E G H P R S T SIMATIC IPC547D 3) 6AG Removable media DVD-ROM 1 DVD±RW Expansions (hardware) Without expansions (HW); 0 onboard graphics No expansions (HW); 1 onboard graphics; DVI-I VGA-compliant adapter cable for onboard graphics Serial (COM) & parallel (LPT); onboard graphics Serial (COM) and parallel (LPT); 3 onboard graphics; DVI-I VGA-compliant adapter cable for onboard graphics Serial (COM) & parallel (LPT) + 4 PCIe x16 graphics card (Dual Head: x VGA or x DVI-D), 51 MB Operating systems (preinstalled and activated) Windows XP Professional, MUI B (Eng, Ger, Fr, It, Sp), 3-bit, SP3 Windows 7 Ultimate, MUI (Eng, E Ger, Fr, It, Sp), 3-bit, SP1 Windows 7 Ultimate, MUI F (Eng, Ger, Fr, It, Sp), 64-bit, SP1 Windows Server 008 Standard P Edition incl. 5 Client, MUI (Eng, Ger, Fr, It, Sp), 3 bit, SP Windows Server 008 R Standard Edition including 5 clients, Q MUI (Eng, Ger, Fr, It, Sp), 64-bit, SP1 Without operating system X Expansions (software) SIMATIC IPC DiagMonitor V4.3 software included SIMATIC IPC Image & Partition Creator V3. software included SIMATIC IPC DiagMonitor V4.3 + Image & Partition Creator V3. software included Without expansions (software) Power supply, with country-specific cable: 100/40 V AC industrial power supply; power cable for Europe 100/40 V AC industrial power supply; USA power cable 100/40 V AC industrial power supply; power cable for China x 100/40 V AC redundant industrial power supply; without power cable 1) Not in combination with redundant power supply ) Can only be used on 64-bit operating systems 3) For an up-to-date overview, see the SIMATIC PC online configurator at: A B C X /780 Siemens IK PI 015

2 Industrial PC Rack PC Ordering data Article No. Article No. SIMATIC IPC547D Preferred variants (ex-stock) Accessories SIMATIC IPC547D Pentium Dual Core G850 (C/T,.90 GHz, 3 MB Last Level Cache, EM64T, VT); 500 GB HDD SATA internal; 1 GB DDR3 SDRAM (1 x 1 GB), single channel; DVD-ROM; interfaces: x Gbit Ethernet (RJ45), 1 x serial, 8 x USB rear, x USB front, 1 x USB internal, x PS/, audio; 100/40 V industrial power supply, power cable for Europe; without operating system Core i5-400 (4C/4T, 3.10 GHz, 6 MB Last Level Cache, Turbo Boost.0, EM64T, VT-x/-d, iamt); RAID1, 1 TB ( x 1 TB HDD SATA, mirror disks) in removable drive bay, for hot swapping, at the front; 4 GB DDR3 SDRAM ( x GB) dual channel; DVD±RW; interfaces: x Gbit Ethernet (RJ45), x serial, 1 x parallel, 8 x USB rear, x USB front, 1 x USB internal, x PS/, Audio; 100/40 V industrial power supply, power cable for Europe; without operating system Core i7-600 (4C/8T, 3.40 GHz, 8 MB Last Level Cache, Turbo Boost.0, EM64T, VT-x/-d, iamt); RAID1, 1 TB ( x 1 TB HDD SATA, mirror disks) in removable drive bay, for hot swapping, at the front; 8 GB DDR3 SDRAM ( x 4 GB) dual channel; DVD±RW; interfaces: x Gbit Ethernet (RJ45), x serial, 1 x parallel, 8 x USB rear, x USB front, 1 x USB internal, x PS/, audio; 100/40 V industrial power supply, power cable for Europe, Windows 7 Ultimate MUI (Eng, Ger, Fr, It, Sp), 64-bit, SP1 supplied 6AG4104-AA01-0XX0 6AG4104-CP-XX0 6AG4104-DP3-FX0 Memory expansion 1 GB DDR SDRAM, DIMM (1 x 1 GB) GB DDR SDRAM, DIMM, kit for dual-channel technology ( x 1 GB) 4 GB DDR SDRAM, DIMM, kit for dual-channel technology ( x GB) 8 GB DDR SDRAM, DIMM, kit for dual-channel technology ( x 4 GB) Tower Kit For converting the computer into an industrial tower PC Retainer for pin assignment of the internal USB port Power cable, straight, 3 m long Austria, Belgium, Finland, France, Germany, Netherlands, Spain, Sweden United Kingdom Switzerland USA Italy China Rack unit for low-profile HDD removable drive bay for 3.5" hard disk, SATA (without hard disk) Expansion components 6ES7648-AJ40-0LA0 6ES7648-AJ50-0LB0 6ES7648-AJ60-0LB0 6ES7648-AJ70-0LB0 6ES7648-1AA00-0XC0 6ES7648-1AA00-0XK0 6ES7900-0AA00-0XA0 6ES7900-0BA00-0XA0 6ES7900-0CA00-0XA0 6ES7900-0DA00-0XA0 6ES7900-0EA00-0XA0 6ES7900-0FA00-0XA0 6ES7648-0EG00-1BA0 See catalog ST 80 / ST PC Note: Software Packages with SIMATIC WinCC flexible, SIMATIC WinCC RT Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC at favorable prices. More information under "Embedded Bundles / Packages for industrial PCs". More information Further information can be found on the Internet at: Siemens IK PI 015 /781

3 Industrial PC Rack PC SIMATIC IPC647D Overview IPC 647D front view The SIMATIC IPC647D is a very rugged, high-performance industrial PC in 19" rack design ( U) with excellent industrial functionality. It offers: Extreme compactness Extreme ruggedness 4th generation Intel Core i technology Benefits Extremely compact and industry-compatible for 4-hour continuous use in an industrial environment Compact enclosure design ( HMs) Suitable for installing in space-saving control cabinets only 500 mm deep Maximum processor performance (in maximum configuration) without loss of power (throttling) at ambient temperatures of up to 50 C Distinct product design with new front design and fullycoated, dirt-resistant surfaces All-metal housing with high EMC for use in industrial environment Dust protection thanks to overpressure ventilation concept with fan on the front and dust filter Special hard disk holders and card retainers for protection against vibration and shock High productivity thanks to faster data processing 4th generation Intel processors: Xeon, Core i5 or Core i3 with turbo-boost, hyper-threading and virtualization technology Graphics controller (HD 4600 graphics) integrated in the processor for exceptionally high graphics performance Maximum performance (e.g. Intel C6 Express chipset, DDR3 memory with the support of dual-channel technology) High data transfer rates (e.g. PCI-Express technology: Gen and Gen 3, USB 3.0 SuperSpeed (500 Mbit/s), SATA III / 6 Gbit/s) Reduction in downtimes through high system availability Secure 4-hour operation (high MTBF, variable-speed fan) at ambient temperature up to 50 C High degree of data security thanks to RAID configurations (RAID controllers onboard) RAID1 configuration: data mirroring on two SATA hard disks, also in hot-removable drive bay "Hot swap" HDD in removable drive bay in RAID configurations (replacement of hard disk during operation) Fast identification and replacement of the hard disk in the event of a fault by means of HDD alarm LEDs for RAID configurations and unambiguous numbering Status display (front LEDs) for Ethernet and PROFIBUS or PROFINET; alarm indication for fan, temperature, watchdog and hard disks in RAID1/5 configurations Efficient self-diagnostics per SIMATIC PC DiagBased or DiagMonitor software (optional) Remote control and maintenance with iamt 9.0 (Intel Active Management Technology) Solid-state drive (SSD) in multi-level cell (MLC) architecture and ECC memory (optional) Redundant power supply with "hot swap" functionality (replacement of power supply module during operation) Redundant gigabit LAN connections (teaming capability) Securing of the replaceable components at the front (e.g. USB software dongle) against unauthorized access by means of a lockable door Locked fan cover: Filter mat and front fan can only be replaced when front door is open The enclosure cover can only be opened if the front door is open Secure internal USB slot in device for software dongle, for example Service-friendly device design (modifications, service) e.g. filter replacement or front fan replacement without tools Cost reductions through high investment security Availability of 3 to 6 years, guaranteed availability of spare parts for 5 years System-tested with SIMATIC components Certification for worldwide marketing (culus) Support for legacy interfaces (PS/, COM, LPT) Installation compatible for many device generations Worldwide service and support Reduced costs due to time savings for commissioning, operation and servicing High degree of flexibility and expandability thanks to integrated interfaces and up to 4 slots (PCI and PCI-Express) Preinstalled and activated operating system Fast restoration of the delivery status of the HDD thanks to restore DVD Low noise output thanks to controlled fan Universal implementation as an industrial workstation or server PROFIBUS or PROFINET interface and RAID1 controller onboard (optional) x LAN 10/100/1000 Mbit/s connections (Gbit LAN with teaming capability) Flexible application options in locations with telescopic rails or as desktop industrial PC Remote maintenance with iamt technology and SIMATIC IPC Remote Manager software /78 Siemens IK PI 015

4 Industrial PC Rack PC SIMATIC IPC647D Technical specifications SIMATIC IPC647D SIMATIC IPC647D General features Drives Design Processor Chipset Main memory Spare slots for expansions (all long) Graphics Operating system Power supply 19" rack, U, external coating Intel Xeon E3-168L v3 4C/8T,.3 (3.3) GHz, 8 MB cache, turbo-boost.0, Extended Memory 64 (EM64) and virtualization technology (VT-x/-d), iamt 9.0 Intel Core i5-4570te C/4T,.7 (3.3) GHz, 4 MB cache, turbo-boost.0, Extended Memory 64 (EM64) and virtualization technology (VT-x/-d), iamt 9.0 Intel Core i3-4330te C/4T,.4 GHz, 4 MB cache, Extended Memory 64 (EM64) and virtualization technology (VT-x) Intel C6 From GB DDR SDRAM Dual channel support 4 DIMM bases expandable up to 3 GB 1) ECC memory (optional) PCI slots ( PCI, PCI-Express): x PCI x PCI-Express x16 (8 lanes) Gen 3 or PCI-Express slots (4 PCI-Express): 1 x PCI-Express x16 (4 lanes) Gen 3 1 x PCI-Express x16 (4 lanes) Gen 1 x PCI-Express x16 (4 lanes) Gen 3 1 x PCI-Express x16 (8 lanes) Gen 3 Onboard Intel HD 4600 graphics controller integrated into the processor Dynamic video memory up to 1.7 GB, up to 3840 x 160 pixels at 60 Hz image refresh rate and 3-bit colors PCI Express graphics card (Dual Head: x VGA or x DVI-D) in the PCIe x16 slot (optional) 51 MB, up to 048 x 1536 pixels at 60 Hz image refresh rate and 3-bit colors without Preinstalled, activated, and supplied on restore DVD Windows 7 Ultimate MUI, 3/64-bit Windows Server 008 R incl. 5 Client MUI, 64-bit (MUI: Multi-Language User Interface; 5 languages (English, French, German, Italian, Spanish) Project-specific on request Linux ) Other V AC, Hz; with bridging of temporary power failures in accordance with NAMUR: max. 0 ms at 0.85 % rated voltage Redundant V AC, Hz Serial ATA 3.5" hard disks (HDD) with NCQ technology and serial ATA.5" solid-state drive (SSD) with MLC technology DVD±R/RW, 5.5", SATA Slots for drives Interfaces PROFINET PROFIBUS/MPI Ethernet USB 3.0 USB.0 Serial Parallel VGA DVI-I DisplayPort V1. Keyboard Mouse Audio Mounted internally on the permanent hard disk support: 1x 40 GB SSD Mounted internally in vibration/shockabsorbing hard disk support 1 x 500 GB HDD 1 x 1 TB HDD x 1 TB HDD RAID1 3), 1 TB ( x 1 TB HDD, mirror disks) Installed on the front in the low-profile removable drive bay (hot swapping in RAID configurations): 1 x 500 GB HDD 1 x 1 TB HDD x 1 TB HDD 1 x 40 GB SSD RAID1 3), 1 TB ( x 1 TB HDD, mirror disks) 8x 8x 6x(DVD media) 4 x 10 x 16 x (CD media) Front: x low profile removable drive bays (for 3.5" HDD) 1 x 1.7 mm slimline (for ODD or SSD) Internal: x 3.5" as an alternative to removable drive bays (in the optional, shock and vibration-damped drive cage) 3 x RJ45 (CP 1616-compatible), optional 1 Mbit/s (isolated, compatible with CP 56), optional x 10/100/1000 Mbit/s (RJ45, teaming-capable) 1 x front (high current) x rear (high current) 1 x internal (high current), e.g. for USB dongle 1 x front (high current), can be used with door closed x rear (high current) 9-pin COM1 (V.4) 9-pin COM (V.4) optional LPT1 (optional) Optionally via adapter cable 1x x PS/ PS/ 1 x Line Out; 1x Micro Siemens IK PI 015 /783

5 Industrial PC Rack PC SIMATIC IPC647D Technical specifications (continued) Monitoring functions Basic functionality Temperature Fan Watchdog Monitoring functions via the network Front LEDs Ambient conditions Degree of protection SIMATIC IPC647D Message locally via DiagBase software Overshoot/undershoot of permissible operating temperature range Messages can be evaluated by the application program Speed monitoring x enclosure fans 1 x fan power supply Monitoring of program execution Monitoring time can be parameterized in software Restart can be parameterized in the event of a fault Messages can be evaluated by the application program SIMATIC PC DiagMonitor (optional) Remote monitoring capability for: Watchdog Temperature Fan speed Hard disk monitoring (SMART) System/Ethernet monitoring (heartbeat) Communication: Ethernet interface (SNMP protocol) OPC for integration in SIMATIC software Configuration of client/server architectures, configuration of log files POWER (internal power supply unit, PC switched on) HDD (access to hard disk) ETHERNET1 (Ethernet status, "heartbeat") ETHERNET (Ethernet status, "heartbeat") PROFIBUS/MPI (PROFIBUS status) SF PROFINET (PROFINET status) WATCHDOG (ready/fault indication) TEMP (temperature status) FAN (fan speed monitoring) HDD0 ALARM 4) HDD1 ALARM 4) IP41 at the front, IP0 at the rear acc. to EN 6059 Dust protection with front door closed: G EN 779, 99 % of particles > 0.5 mm are held back Protection class Protection class I according to IEC Vibration load during operation DIN EN , 10 cycles Internal mounting of the hard disk drives in optional, internal drive cage: Hz: mm; Hz: 5m/s (approx. 0.5g) Note: There are limitations when DVD+/-RW and HDD are operated in a removable drive bay Shock loading during operation DIN EN , IEC Internal mounting of the hard disk drives in optional, internal drive cage: Half-sine: 50 m/s, 30 ms (approx. 5 g), 100 shocks per axis Note: There are limitations when DVD+/-RW and HDD are operated in a removable drive bay Electromagnetic compatibility (EMC) Emitted interference (AC) Immunity to conducted interference on the supply lines Noise immunity on signal lines Immunity to static discharge Immunity to high radio frequency interference SIMATIC IPC647D EN , FCC Class A EN ; CISPR, EN 550 Class B EN Class D, EN ± kv (IEC , burst) ±1kV (IEC , symm. surge) ±kv (IEC , asymm. surge) ± 1 kv (IEC , burst, length < 30 m) ± kv (IEC , symm. surge, length > 30 m) ± kv (IEC , asymm. surge, length > 30 m) ± 6 kv, contact discharge (IEC ) ± 8 kv, air discharge (IEC ) 10 V/m, 80 to 1000 MHz and 1.4toGHz, 80% AM (according to IEC ) 3 V/m, to.7 GHz, 80% AM (according to IEC ) 10 V, 10 khz to 80 MHz, 80% AM (according to IEC ) Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC ) Ambient temperature during 5 50 C operation Note: Limitations for operation of DVD+/-RW Humidity during operation % at 30 C (no condensation) Approvals and safety regulations Safety regulations IEC EN UL CSA C. No Approvals culus 60950, KCC CE mark For use in industrial areas as well as domestic, business and commercial environments: Emitted interference: EN : 007 +A1:011 Noise immunity: EN :005 Dimensions and weights Installation dimensions 430 x 88 x 445 (WxHxD) in mm 1) Memory information: In order to use a memory with more than 4 GB, a 64-bit operating system is required. In the case of configurations with at least 4 GB, the visible memory can be reduced to about 3.5 GB or less (with 3-bit operating systems) ) Suitable for specific LINUX versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for LINUX" (LINUX is a trademark of Linus Torvalds). 3) SATA RAID controller on board in Intel chipset 4) Hard disk alarm in conjunction with RAID and monitoring software Note regarding SIMATIC PC operating system licenses The accompanying operating system license is only valid for installation on the respective supplied SIMATIC IPC. Installation can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations. /784 Siemens IK PI 015

6 Industrial PC Rack PC Ordering data Article No. Article No. SIMATIC IPC647D SIMATIC IPC647D 1) 6AG Interfaces: RACK PC, 19", HU; Interfaces: x GBIT LAN (RJ45); 1 x DVI-I; x DisplayPort; 1 x COM; x PS/; Audio; x USB 3.0, x USB.0 at rear; 1 x USB 3.0, 1 x USB.0 at front, 1 x USB 3.0 internal; Temperature and fan monitoring, watchdog, card retainer; Processor/motherboard Core i3-4330te D (C/4T,.4 GHz, 4 MB cache); mainboard without fieldbus Core i3-4330te E (C/4T,.4 GHz, 4 MB, VT-x); mainboard with PROFIBUS/MPI (CP 56-compatible) Core i3-4330te F (C/4T,.4 GHz, 4 MB cache); mainboard with PROFINET (3 x RJ45, CP 1616-compatible) Core i5-4570te G (C/4T,.7 (3.3) GHz, 4 MB Cache, TB, VT-d, AMT); mainboard without fieldbus Core i5-4570te H (C/4T,.7 (3.3) GHz, 4 MB cache, TB, VT-x, VT-d, AMT); mainboard with PROFIBUS/MPI (CP 56-compatible) Core i5-4570te J (C/4T,.7 (3.3) GHz, 4 MB cache, TB, VT-d, AMT); mainboard with PROFINET (3 x RJ45, CP 1616-compatible) Xeon E3-168L v3 K (4C/8T,.3 (3.3) GHz, 8 MB cache, TB, VT-d, AMT); mainboard without fieldbus Xeon E3-168L v3 L (4C/8T,.3 (3.3) GHz, 8 MB cache, TB, VT-x, VT-d, AMT); mainboard with PROFIBUS/MPI (CP 56-compatible) Xeon E3-168L v3 M (4C/8T,.3 (3.3) GHz, 8 MB cache, TB, VT-d, AMT); mainboard with PROFINET (3 x RJ45, CP 1616-compatible) Hard drives / SSD 500 GB HDD SATA, internal A (0.5 g vibration, 5 g shock) 1 TB HDD SATA, internal B (0.5 g vibration, 5 g shock) x 1 TB HDD SATA, internal C (0.5 g vibration, 5 g shock) RAID1, 1 TB D ( x 1 TB HDD SATA, mirror disks), internal (0.5 g vibration, 5 g shock) 500 GB HDD SATA H in removable drive bay; front 1 TB HDD SATA K in removable drive bay; front x 1 TB HDD SAT M in removable drive bay; front RAID1, 1 TB ( x 1 TB HDD SATA, mirror disks) in removable drive bay, hot-swappable, front P 40 GB SSD SATA, internal S 40 GB SSD SATA in removable T drive bay; front 1) For an up-to-date overview, see the SIMATIC IPC online configurator at: SIMATIC IPC647D 1) 6AG Memory configuration GB DDR3 SDRAM (1 x GB), single channel 4 GB DDR3 SDRAM ( x GB), dual channel 8 GB DDR3 SDRAM ( x 4 GB), dual channel 16 GB DDR3 SDRAM ( x 8 GB), dual channel 3 GB DDR3 SDRAM (4 x 8 GB), dual channel 8 GB DDR3 SDRAM, ( x 4 GB), ECC, dual channel 16 GB DDR3 SDRAM, ( x 8 GB), ECC, dual channel 3 GB DDR3 SDRAM, (4 x 8 GB), ECC, dual channel Bus module / swap media / SSD: Bus module -slot: x PCIe x16; without drives Bus module 4-slot: x PCI, x PCIe x16; without drives Bus module 4-slot: 4 x PCIe x16; without drives Bus module -slot: x PCIe x16; DVD±RW (slim) Bus module 4-slot: x PCI, x PCIe x16; DVD±RW (slim) Bus module 4-slot: 4 x PCIe x16; DVD±RW (slim) Bus module -slot: x PCIe x16 / 1 x 40 GB SSD (for operating system), internal Bus module 4-slot: x PCI, x PCIe x16 / 1 x 40 GB SSD (for operating system), internal Bus module 4-slot: 4 x PCIe x16 / 1 x 40 GB SSD (for operating system), internal Expansion hardware Without expansions (hardware), onboard graphics; Without expansions (hardware), onboard graphics, DVI-I adapter cable, VGA-compliant for onboard graphics; Serial (COM) + parallel (LPT, 1 slot reserved), onboard graphics; Serial (COM) + parallel (LPT, 1 slot reserved), onboard graphics; DVI-I adapter cable, VGA-compliant for onboard graphics; Serial (COM) + Parallel (LPT, 1 slot reserved) + PCIe x16 Graphics Card (Dual-Head: x VGA or x DVI-D), 51 MB, (1 slot reserved); Siemens IK PI 015 /785

7 Industrial PC Rack PC SIMATIC IPC647D Ordering data Article No. Article No. SIMATIC IPC647D 1) 6AG Accessories Operating system (preinstalled and activated) Windows 7 Ultimate, 3-bit MUI (Eng, Ger, Fr, It, Sp), SP1 Windows 7 Ultimate, 64-bit MUI (Eng, Ger, Fr, It, Sp), SP1 Windows Server 008 R Standard Edition incl. 5 Clients, 64-bit, MUI (Eng, Ger, Fr, It, Sp), SP1 Without operating system Expansions (software) / Security SIMATIC IPC DiagMonitor software V4.4 included SIMATIC IPC Image Creator software V3.3 included SIMATIC IPC DiagMonitor 4.4 and Image Creator Software 3.3 included Without software Without expansions (software) / TPM (not for China and Russia) Power supply, country-specific cable 110 / 40 V industrial power supply unit with NAMUR; power cable for Europe 110 / 40 V industrial power supply unit with NAMUR; power cable for United Kingdom 110 / 40 V industrial power supply unit with NAMUR; power cable for Switzerland 110 / 40 V industrial power supply unit with NAMUR; power cable for USA 110 / 40 V industrial power supply unit with NAMUR; power cable for Italy 110 / 40 V industrial power supply unit with NAMUR; power cable for China x 110 / 40 V redundant power supply; without power cable 1) For an up-to-date overview, see the SIMATIC IPC online configurator at: A B F X A B C X Y Memory expansions GB DDR DIMM 4 GB DDR DIMM 8 GB DDR DIMM 8 GB DDR DIMM, ECC Hardware accessories Rack unit for low-profile removable drive bay For 3.5" hard drive (SATA/SAS) and.5" SSD (SATA), without drive Filter mats for SIMATIC IPC647D (packing unit: 10 units) Adapter cable Adapter cable DisplayPort to DVI-D for onboard graphics Adapter cable DisplayPort to VGA for onboard graphics Power cable, straight, 3 m long Austria, Belgium, Finland, France, Germany, Netherlands, Spain, Sweden United Kingdom Switzerland USA Italy China USB retainer for interlocking the internal USB port Expansion components 6ES7648-AJ50-0MA0 6ES7648-AJ60-0MA0 6ES7648-AJ70-0MA0 6ES7648-AJ70-1MA0 6ES7648-0EG01-1BA0 A5E ES7648-3AF00-0XA0 6ES7648-3AG00-0XA0 6ES7900-0AA00-0XA0 6ES7900-0BA00-0XA0 6ES7900-0CA00-0XA0 6ES7900-0DA00-0XA0 6ES7900-0EA00-0XA0 6ES7900-0FA00-0XA0 6ES7648-1AA00-0XK0 See catalog ST 80 / ST PC Note: Software Packages with SIMATIC WinCC flexible, WinCC RT Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC at a price advantage. More information under "Embedded Bundles / Packages for industrial PCs". More information Additional information is available on the Internet at: /786 Siemens IK PI 015

8 Overview IPC 847D front view The SIMATIC IPC847D is an extremely robust, high-performance industrial PC in 19" rack design (4 U) with excellent industrial functionality. It offers: Maximum expandability Extreme ruggedness 4th generation Intel Core i technology Benefits Maximum industrial compatibility and compactness for 4-hour use in an industrial environment Maximum processor performance (in maximum configuration) without loss of power (throttling) at ambient temperatures of up to 50 C Distinct product design with new front design and fullycoated, dirt-resistant surfaces All-metal housing with high EMC for use in industrial environment Suitable for installing in space-saving control cabinets only 500 mm deep Dust protection thanks to overpressure ventilation concept with fan on the front and dust filter Special hard disk holders and card retainers for protection against vibration and shock High productivity thanks to faster data processing 4th generation Intel processors: Xeon, Core i5 or Core i3 with turbo-boost, hyper-threading and virtualization technology Graphics controller (HD graphics 4600) integrated in the processor for exceptionally high graphics performance Maximum performance (e.g. Intel C6 Express chipset, DDR3 memory with the support of dual-channel technology) High data transfer rates (e.g. PCI-Express technology: Gen and Gen 3, USB 3.0 SuperSpeed (500 Mbit/s), SATA III/6 Gbit/s) Reduction in downtimes through high system availability Secure 4-hour operation (high MTBF, variable-speed fan) at ambient temperature up to 50 C High data security thanks to RAID configurations (RAID controller onboard) RAID1 configuration: Redundant data storage on two SATA hard disks, also in hot-removable drive bays and with additional SSD (for operating system) or hot spare hard disk option Industrial PC Rack PC SIMATIC IPC847D RAID5 configuration: Striping with parity on three SATA hard disks for increased memory capacity in hot-removable drive bays, with additional hot spare hard disk option "Hot swap" HDD in removable drive bay in RAID configurations (replacement of hard disk during operation) "Hot spare" HDD in removable drive bay in RAID configurations (the rebuild process on the "hot spare" hard disk starts up automatically) Fast identification and replacement of the hard disk in the event of a fault by means of HDD alarm LEDs for RAID configurations and unambiguous numbering Status display (front LEDs) for Ethernet and PROFIBUS or PROFINET; alarm indication for fan, temperature, watchdog and hard disks in RAID1/5 configurations Efficient self-diagnostics per SIMATIC PC DiagBased or DiagMonitor software (optional) Remote control and maintenance with iamt 9.0 (Intel Active Management Technology) Solid-state drive (SSD) in multi-level cell (MLC) architecture and ECC memory (optional) Redundant power supply with "hot swap" functionality (replacement of power supply module during operation) Redundant Gbit LAN connections (teaming capability) Securing of the replaceable components at the front (e.g. USB software dongle) against unauthorized access by means of a lockable door Locked fan cover: Filter mat and front fan can only be replaced when front door is open The enclosure cover can only be opened if the front door is open Secure internal USB slot in device for software dongle, for example Service-friendly device design (modifications, service) e.g. filter replacement or front fan replacement without tools Cost reductions through high investment security Platform with long-term stability and embedded Intel components Availability of 3 to 6 years, guaranteed availability of spare parts for 5 years System-tested with SIMATIC components Certification for worldwide marketing (culus) Support for legacy interfaces (PS/, COM, LPT) Installation compatible for many device generations Worldwide service and support Reduced costs due to time savings for commissioning, operation and servicing High degree of flexibility and expandability thanks to integrated interfaces and up to 11 slots (PCI and PCI-Express) Preinstalled and activated operating system Fast restoration of the delivery status of the HDD thanks to restore DVD Low noise output thanks to controlled fan Universal implementation as an industrial workstation or server PROFIBUS or PROFINET interface and RAID1/5 controller onboard (optional) x LAN 10/100/1000 Mbit/s connections (Gbit LAN with teaming capability) Flexible applications in many different positions with telescopic rails or as tower industrial PC Remote maintenance with iamt technology and SIMATIC IPC Remote Manager software Siemens IK PI 015 /787

9 Industrial PC Rack PC SIMATIC IPC847D Technical specifications SIMATIC IPC847D SIMATIC IPC847D Drives Serial ATA 3.5" hard disks (HDD) with NCQ technology and serial ATA.5" solid-state drive (SSD) with MLC technology General features Design Processor Chipset Main memory Spare slots for expansions (all 31 mm long) Graphics Operating system Power supply 19" rack, 4 U, externally painted Intel Xeon E3-168L v3 4C/8T,.3 (3.3) GHz, 8 MB cache, turbo-boost.0, Extended Memory 64 (EM64) and virtualization technology (VT-x/-d), iamt 9.0 Intel Core i5-4570te C/4T,.7 (3.3) GHz, 4 MB cache, turbo-boost.0, Extended Memory 64 (EM64) and virtualization technology (VT-x/-d), iamt 9.0 Intel Core i3-4330te C/4T,.4 GHz, 4 MB cache, Extended Memory 64 (EM64) and virtualization technology (VT-x) Intel C6 From GB DDR SDRAM Dual channel support 4 DIMM base Expandable up to 3 GB 1) ECC memory (optional) More PCI slots (7 PCI, 4 PCI-Express): 7x PCI 1 x PCI-Express x16 (16 lanes) Gen 3 3 x PCI-Express x4 (1 lane) Gen or More PCI-Express slots (8 PCI-Express, 3 PCI): 3x PCI 1 x PCI-Express x16 (8 lanes) Gen 3 x PCI-Express x16 (4 lanes) Gen 3 x PCI-Express x16 (4 lanes) Gen 3 x PCI-Express x4 (4 lane) Gen Onboard Intel HD 4600 graphics controller integrated into the processor Dynamic Video Memory up to 1.7 GB Up to 3840 x 160 pixels at 60 Hz image refresh rate and 3-bit colors PCI Express graphics card (Dual Head: x VGA or x DVI-D) in the PCIe x16 slot (optional) 51 MB, up to 048 x 1536 pixels at 60 Hz image refresh rate and 3- bit colors without Preinstalled and activated / supplied on restore DVD Windows 7 Ultimate MUI, 3/64-bit Windows Server 008 R incl. 5 client MUI, 64-bit MUI: Multi-language User Interface; 5 languages (English, French, German, Italian, Spanish) Project-specific on request Linux ) Other V AC, Hz with bridging of temporary power failures in accordance with NAMUR: max. 0 ms at 0.85 % rated voltage Redundant V AC, Hz DVD+/-R/RW, slim, SATA Slots for drives Interfaces PROFINET PROFIBUS/MPI Ethernet USB 3.0 USB.0 Serial Mounted internally on the permanent hard disk support: 1 x 500 GB HDD 1 x 40 GB SSD Can be installed in internal shock and vibration-damped drive cage (optional) 1 x 500 GB HDD 1 x 1 TB HDD x 1 TB HDD RAID1 3), 1 TB ( x 1 TB HDD, mirror disks) RAID1 3), 1 TB ( x 1 TB HDD, mirror disks) + 1 x 40 GB SSD (for operating system) in removable drive bay Installed on the front in the low-profile removable drive bay (hot swapping in RAID configurations): 1 x 500 GB HDD 1 x 1 TB HDD x 1 TB HDD 1 x 40 GB SSD RAID1 3), 1 TB ( x 1 TB HDD, mirror disks) RAID1 3), 1 TB ( x 1 TB HDD, mirror disks) + 1 x 1 TB HDD as hot spare RAID1 3), 1 TB ( x 1 TB HDD, mirror disks) + 1 x 40 GB SSD (for operating system) RAID5 3), TB (3 x 1 TB HDD, striping with parity) RAID5 3), TB (3 x 1 TB HDD, striping with parity) + 1 x 1 TB HDD as hot spare 8x 8x 6x(DVD media) 4 x 10 x 16 x (CD media) Front: 3 x 5.5" / 4 x low-profile removable drive bay 1 x slim (ODD) Internal: x 3.5" or x 3.5" (in the optional, vibrationdamping drive cage) 3x RJ45 (CP 1616-compatible), optional 1 Mbit/s (isolated, compatible with CP 56), optional x 10/100/1000 Mbit/s (RJ45, teaming-capable) 1 x front (high current) x rear (high current) 1 x internal (high current), e.g. for USB dongle 1 x front (high current), can be used with door closed x rear; (high current) 9-pin COM1 (V.4) 9-pin COM (V.4) (optional) LPT1 (optional) Optionally via adapter cable 1x x PS/ PS/ 1 x Line Out; 1 x Micro Parallel VGA DVI-I DisplayPort V1. Keyboard Mouse Audio /788 Siemens IK PI 015

10 Industrial PC Rack PC SIMATIC IPC847D Technical specifications (continued) Monitoring functions Basic functionality Temperature Fan Watchdog Monitoring functions via the network Front LEDs Ambient conditions Degree of protection SIMATIC IPC847D Message locally via DiagBase software Overshoot/undershoot of permissible operating temperature range Messages can be evaluated by the application program Speed monitoring x enclosure fans 1 x fan power supply Monitoring of program execution Monitoring time can be parameterized in software Restart can be parameterized in the event of a fault Messages can be evaluated by the application program SIMATIC PC DiagMonitor (optional) Remote monitoring capability for: Watchdog Temperature Fan speed Hard disk monitoring (SMART) System/Ethernet monitoring (Heartbeat) Communication: Ethernet interface (SNMP protocol) OPC for integration in SIMATIC software Configuration of client/server architectures Structure of log files POWER (internal power supply unit, PC switched on) ETHERNET1 (Ethernet status, "Heartbeat") ETHERNET (Ethernet status, "Heartbeat") PN / MPI/DP (PROFINET/PROFIBUS status) WATCHDOG (ready/fault indication) TEMP (temperature status) FAN (fan speed monitoring) HDD0 ALARM 4) HDD1 ALARM 4) HDD ALARM 4) HDD (access to hard disk) / HDD3 ALARM 4) IP41 at the front, IP0 at the rear acc. to EN 6059 Dust protection With front door closed: G EN 779, 99 % of particles > 0.5 mm are held back Protection class Protection class I according to IEC Vibration load during operation DIN EN , 10 cycles Internal mounting of the hard disk drives in optional, internal drive cage: Hz: mm; Hz: 5m/s (approx. 0.5g) Permanently installed internal hard disk drives: Hz: mm; Hz: 3m/s (approx. 0.3g) Note: There are limitations when DVD+/-RW and HDD are operated in a removable drive bay SIMATIC IPC847D Shock loading during operation DIN EN , IEC Internal mounting of the hard disk drives in optional, internal drive cage: Half-sine: 50 m/s, 30 ms (approx. 5 g), 100 shocks per axis Permanently installed internal hard disk drives: 30 m/s, 30 ms (approx. 3 g) Note: There are limitations when DVD+/-RW and HDD are operated in a removable drive bay Electromagnetic compatibility (EMC) Emitted interference (AC) EN , FCC Class A EN ; CISPR, EN 550 Class B EN Class D, EN Immunity to conducted interference on the supply lines Noise immunity on signal lines Immunity to static discharge Immunity to high radio frequency interference ± kv (IEC , burst) ±1kV (IEC , symm. surge) ±kv (IEC , asymm. surge) ± 1 kv (IEC , burst, length < 30 m) ± kv (IEC , symm. surge, length > 30 m) ± kv (IEC , asymm. surge, length > 30 m) ± 6 kv, contact discharge (IEC ) ± 8 kv, air discharge (IEC ) 10 V/m, 80 to 1000 MHz and 1.4toGHz, 80% AM (according to IEC ) 3 V/m, to.7 GHz, 80% AM (to IEC ) 10 V, 10 khz to 80 MHz, 80% AM (according to IEC ) Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC ) Ambient temperature during C operation Note: Limitations for operation of DVD+/-RW Relative humidity during operation % at 5 C (no condensation) Approvals and safety regulations Safety regulations IEC EN UL CSA C. No Approvals culus Second Edition, KCC CE mark Emitted interference: EN : 007 +A1:011 Noise immunity: EN :005 Dimensions and weights Installation dimensions 430 x 177 x 448 (WxHxD) in mm 1) Memory information: in order to use a memory with more than 4 GB, a 64-bit operating system is required. In the case of configurations with at least 4 GB, the visible memory can be reduced to about 3.5 GB or less (with 3-bit operating systems). ) Suitable for specific LINUX versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for LINUX" (LINUX is a trademark of Linus Torvalds). 3) SATA RAID controller on board in Intel chipset 4) Hard disk alarm in conjunction with RAID and monitoring software Note regarding SIMATIC PC operating system licenses The accompanying operating system license is only valid for installation on the respective supplied SIMATIC IPC. Installation can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations. Siemens IK PI 015 /789

11 Industrial PC Rack PC SIMATIC IPC847D Ordering data Article No. Article No. SIMATIC IPC847D 1) 6AG Interfaces: RACK PC, 19", 4 U; Interfaces: x GBIT LAN (RJ45); 1 x DVI-I; x DisplayPort; 1 x COM; x PS/; Audio; x USB 3.0, x USB.0 at rear; 1 x USB 3.0, 1 x USB.0 at front, 1 x USB 3.0 internal; Temperature and fan monitoring, watchdog, card retainer; Processor/motherboard Core i3-4330te D (C/4T,.4 GHz, 4 MB cache); mainboard without fieldbus Core i3-4330te (C/4T,.4 GHz, E 4 MB cache, VT-x); mainboard with PROFIBUS/MPI (CP 56-compatible) Core i3-4330te F (C/4T,.4 GHz, 4 MB cache); mainboard with PROFINET (3 x RJ45, CP 1616-compatible) Core i5-4570te G (C/4T,.7 (3.3) GHz, 4 MB Cache, TB, VT-d, AMT); mainboard without fieldbus Core i5-4570te H (C/4T,.7 (3.3) GHz, 4 MB cache, TB, VT-x, VT-d, AMT); mainboard with PROFIBUS/MPI (CP 56-compatible) Core i5-4570te J (C/4T,.7 (3.3) GHz, 4 MB cache, TB, VT-d, AMT); mainboard with PROFINET (3 x RJ45, CP 161-compatible) Xeon E3-168L v3 K (4C/8T,.3 (3.3) GHz, 8 MB cache, TB, VT-d, AMT); mainboard without fieldbus Xeon E3-168L v3 L (4C/8T,.3 (3.3) GHz, 8 MB cache, TB, VT-x, VT-d, AMT); mainboard with PROFIBUS/MPI (CP 56-compatible) Xeon E3-168L v3 M (4C/8T,.3 (3.3) GHz, 8 MB cache, TB, VT-d, AMT); mainboard with PROFINET (3 x RJ45, CP 1616-compatible) Drives 500 GB HDD SATA, internal A (0.3 g vibration, 3 g shock) 500 GB HDD SATA, internal B (0.5 g vibration, 5 g shock) 1 TB HDD SATA, internal C (0.5 g vibration, 5 g shock) x 1 TB HDD SATA, internal D (0.5 g vibration, 5 g shock) RAID1, 1 TB ( x 1 TB HDD SATA, E mirror disks), internal (0.5 g vibration, 5 g shock) 500 GB HDD SATA in removable F drive bay; front 1 TB HDD SATA in removable G drive bay; front x 1 TB HDD SAT in removable H drive bay; front RAID1, 1 TB ( x 1 TB HDD SATA, J mirror disks) in removable drive bay, hot-swappable, front; RAID5, TB (3 x 1 TB HDD, SATA, K striping with parity) in removable drive bay, hot-swappable, front 1) For an up-to-date overview, see the SIMATIC IPC online configurator at: SIMATIC IPC847D 1) 6AG Drives (continued) RAID5, TB (3 x 1 TB HDD, SATA, striping with parity) in removable drive bay, hot swap + 1 TB SATA HDD as hot spare in removable drive bay, front; 40 GB SSD SATA, internal 40 GB SSD SATA in removable drive bay; front RAID1, 1 TB ( x 1 TB HDD SATA, mirror disks), internal (0.5 g vibration, 5 g shock) + 40 GByte SSD SATA (for operating system) in removable drive bay RAID1, 1 TB ( x 1 TB HDD, SATA, mirror disks) in removable drive bay, hot swap + 1 TB HDD SATA as hot spare in removable drive bay, front; RAID1, 1 TB ( x 1 TB HDD SATA, mirror disks) i+ 40 GByte SSD SATA (for operating system) in removable drive bay, hot-swap; front Memory configuration GB DDR3 SDRAM (1 x GB), single channel 4 GB DDR3 SDRAM ( x GB), dual channel 8 GB DDR3 SDRAM ( x 4 GB), dual channel 16 GB DDR3 SDRAM ( x 8 GB), dual channel 3 GB DDR3 SDRAM (4 x 8 GB), dual channel 8 GB DDR3 SDRAM, ( x 4 GB), ECC, dual channel 16 GB DDR3 SDRAM, ( x 8 GB), ECC, dual channel 3 GB DDR3 SDRAM, (4 x 8 GB), ECC, dual channel Bus module / swap media Bus module 11-slot: 7 x PCI, 3 x PCIe x4, 1 x PCIe x16; without swap media Bus module 11-slot: 3 x PCI, 3 x PCIe x4, 5 x PCIe x16; without swap media Bus module 11-slot: 7 x PCI, 3 x PCIe x4, 1 x PCIe x16; DVD±RW (slim) Bus module 11-slot: 3 x PCI, 3 x PCIe x4, 5 x PCIe x16; DVD±RW (slim) Expansion hardware Without expansions (hardware), onboard graphics; Without expansions (hardware), onboard graphics, DVI-I adapter cable, VGA-compliant for onboard graphics; Serial (COM) + parallel (LPT, 1 slot reserved), onboard graphics; Serial (COM) + parallel (LPT, 1 slot reserved), onboard graphics; DVI-I adapter cable, VGA-compliant for onboard graphics; Serial (COM) + Parallel (LPT, 1 slot reserved) + PCIe x16 Graphics Card (Dual- Head: x VGA or x DVI-D), 51 MB, (1 slot reserved); L M N P Q R /790 Siemens IK PI 015

12 Industrial PC Rack PC Ordering data Article No. Article No. SIMATIC IPC847D SIMATIC IPC847D 1) 6AG Accessories Operating system (preinstalled and activated) Windows 7 Ultimate, 3-bit MUI (Eng, Ger, Fr, It, Sp), SP1 Windows 7 Ultimate, 64-bit MUI (Eng, Ger, Fr, It, Sp), SP1 Windows Server 008 R Standard Edition incl. 5 Clients, 64-bit, MUI (Eng, Ger, Fr, It, Sp), SP1 Without operating system Expansions (software) / Security SIMATIC IPC DiagMonitor software V4.4 included SIMATIC IPC Image Creator software V3.3 included SIMATIC IPC DiagMonitor 4.4 and Image Creator Software 3.3 included Without software (software) Without expansions (software) / TPM (not for China and Russia) Power supply, country-specific cable 110 / 40 V industrial power supply unit with NAMUR; power cable for Europe 110 / 40 V industrial power supply unit with NAMUR; power cable for United Kingdom 110 / 40 V industrial power supply unit with NAMUR; power cable for Switzerland 110 / 40 V industrial power supply unit with NAMUR; power cable for USA 110 / 40 V industrial power supply unit with NAMUR; power cable for Italy 110 / 40 V industrial power supply unit with NAMUR; power cable for China x 110 / 40 V redundant power supply; without power cable A B F X A B C X Y Memory expansions GB DDR DIMM 4 GB DDR DIMM 8 GB DDR DIMM 8 GB DDR DIMM, ECC Hardware accessories Rack unit for low-profile removable drive bay For 3.5" hard drive (SATA/SAS) and.5" SSD (SATA), without drive Filter mats for SIMATIC IPC847D (packing unit: 10 units) Adapter cable DisplayPort to DVI-D for onboard graphics DisplayPort to VGA for onboard graphics Power cable, straight, 3 m long Austria, Belgium, Finland, France, Germany, Netherlands, Spain, Sweden United Kingdom Switzerland USA Italy China Tower Kit for converting the computer into an industrial tower PC USB retainer for interlocking the internal USB port Expansion components 6ES7648-AJ50-0MA0 6ES7648-AJ60-0MA0 6ES7648-AJ70-0MA0 6ES7648-AJ70-1MA0 6ES7648-0EG01-1BA0 A5E ES7648-3AF00-0XA0 6ES7648-3AG00-0XA0 6ES7900-0AA00-0XA0 6ES7900-0BA00-0XA0 6ES7900-0CA00-0XA0 6ES7900-0DA00-0XA0 6ES7900-0EA00-0XA0 6ES7900-0FA00-0XA0 6ES7648-1AA00-0XD0 6ES7648-1AA00-0XK0 See catalog ST 80 / ST PC 1) For an up-to-date overview, see the SIMATIC IPC online configurator at: Note: Software Packages with SIMATIC WinCC flexible, WinCC RT Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC at a price advantage. More information under "Embedded Bundles / Packages for industrial PCs". More information Additional information is available on the Internet at: Siemens IK PI 015 /791

13 Industrial PC Box PC General data Overview SIMATIC Box PC family SIMATIC Box PCs provide mechanical engineers, plant engineers and control cabinet makers with particularly rugged industrial PC systems for use in powerful yet compact applications. The following device classes are available for various requirements: SIMATIC IPC7 (Nanobox PC): The compact embedded IPC maintenance-free and dustproof with versatile mounting SIMATIC IPC47 (Microbox PC): The powerful embedded IPC maintenance-free with versatile configuration SIMATIC IPC67/IPC87 (Box PC): The high-end IPC with maximum performance, functional scope, and expansion capability Shared industrial functionality: Extreme compactness Certification for global marketing System-tested with SIMATIC components High vibration/shock load during operation Wide operational temperature range Robust data storage with CompactFlash/CFast or Solid-State Drive (SSD) Integrated PROFIBUS or PROFIBUS/MPI interface (optional) Varied mounting possibilities for flexibility with installation Designed for 4-hour continuous operation Integrated parameterizable monitoring functions (temperature, fan, watchdog) High service friendliness Operating system preinstalled and activated for fast startup Motherboard developed and manufactured by Siemens Availability for 3 to 6 years Repairs and spare parts service for 5 years High component/design continuity Installation and software compatible with predecessor model Long-term availability of PC components from the Intel embedded line SIMATIC IPC7 (Nanobox PC): The compact embedded IPC maintenance-free and dust-proof with versatile mounting Maximum compactness with approx. 1 liter enclosure volume with integrated industrial power supply for minimum space requirements in the control cabinet Maximum flexibility thanks four mounting options and interfaces on one side suitable for every installation situation Optimum variety of interfaces due to a large number of integrated interfaces such as selectable serial ports (RS 3/ RS 485/CAN) and x teaming-capable Gigabit Ethernet Maximum industrial functionality due to closed enclosure for optimum dust protection and non-volatile retentive memory Further device options for optimum adaptation to the application with additional PCIe slot or RS 3 interfaces or digital I/O SIMATIC IPC47 (Microbox PC): The powerful embedded IPC maintenance-free with versatile configuration Fan-free operation High performance with maximum compactness and ruggedness for direct installation in the machine Optimized for embedded applications Flexibility expandable using one or two PCIe I/O cards (optional) Flexible installation options due to DIN rail/wall/front upright mounting, even outside a control cabinet NVRAM for retentive data storage (optional) SIMATIC IPC67/IPC87 (Box PC): The high-end IPC with maximum performance, functional scope, and expansion capability Maximum system performance for complex measuring, control and visualization tasks High flexibility with expansion slots and integral interfaces Flexible, space-saving installation with mounting brackets or portrait assembly kits Rugged design for direct installation in the machine RAID1 controller onboard Maximum processor performance up to ambient temperature of 55 C High system availability Battery-backed SRAM as memory for WinAC data 4 signaling LEDs /79 Siemens IK PI 015

14 Benefits Compact dimensions The SIMATIC IPC7D is a particularly compact and energyefficient PC in the Nano format. The heart of the Nanobox PC with particularly many mounting options are high-performance Intel Atom processors of the latest generation. The SIMATIC IPC47 (Microbox PC) is an ultra-compact and rugged device for DIN rail mounting, portrait or wall mounting, and for use in the machine: mounting depth from 47 mm. With a maximum mounting depth of 100 mm (80 mm without DVD drive), the SIMATIC IPC67 (Box PC) can be used even in the smallest of spaces. In addition, space-saving portrait mounting is possible with the SIMATIC Box IPC67/IPC87. Rugged design All designs aim to achieve maximum safety in the case of vibration and shock loads. For example, a special vibration-absorbing suspension of the hard disk ensures operational reliability, even at very high mechanical loads. A flash drive slot, which is easily accessible from outside, or the solid-state drive (SSD) in the single level cell (SLC) architecture, which is particularly suitable for industrial applications, is available for setting up lowmaintenance, fault-tolerant, diskless systems. Thanks to its fanfree design and use of CompactFlash cards, the Microbox PC and the new Nanobox PC are especially suitable for maintenance-free 4-hour continuous operation. Service-friendly device design The Box PC can simply be folded out for speedy component replacement. The inside of the device is easily accessible for future expansions. Technical specifications Industrial PC Box PC General data Integrated interfaces On Box PCs, all interfaces are located on one side. Box PCs can be interfaced with the control/cell level via onboard Ethernet interfaces and communicate in the field via an integrated PROFIBUS interface, which is available as an option. External monitors or displays can be connected via a VGA or DVI-I interface. Flexibility Especially the SIMATIC IPC87 with its 5 free PC slots offers many expansion options. All Box PCs have CE certification for use in industrial applications and domestic/commercial applications and can therefore be used in building automation or public installations in addition to industrial applications. Continuity Thanks to motherboards developed and manufactured inhouse, the SIMATIC Box PCs offer very high continuity and security of investment. The SIMATIC Box PC models can normally be ordered for a period of three years and spare parts are obtainable for at least 5 years after active marketing is concluded. System availability SIMATIC Box PCs can be ordered in custom configurations and are supplied ready for use. The high system availability by design can be further extended by means of additional data backup options (e.g. RAID system, SIMATIC IPC Image & Partition Creator) and efficient software for self-diagnostics (SIMATIC IPC DiagMonitor). SIMATIC IPC7D (Nanobox PC) SIMATIC IPC47D (Microbox PC) SIMATIC IPC67D (Box PC) Design Rail or wall mounting - - Wall or portrait mounting Also: Side mounting General features Processor Intel Atom E MHz Intel Atom E GHz Intel Atom E GHz Intel Core i7-3517ue, 1.7 GHz, 4 MB SLC Intel Core i3-317ue, 1.6 GHz, 3 MB SLC Intel Celeron 87E 1.4 GHz, 1.5 MB SLC Intel Xeon processor E3-168L v3 (4 cores, 8 threads,.3 (3.3) GHz, 8 MB cache, VT-d, AMT) Intel Core i3-4330te processor ( cores, 4 threads,.4 GHz, 4 MB cache, VT-x) Intel Celeron G180TE (C/T,. GHz, MB cache) Main memory 51 MB, 1 GB, GB 1 GB, GB, 4 GB, 8 GB GB, expandable up to 16 GB, optional ECC Static RAM 51 KB 51 KB MB MB Free slots for expansions 1 x PCIe Up to x PCIe with PCIe enclosure option (enclosure option) x PCI or 1 x PCIe x16 / 1 x PCI x PCIe (x16/x4) Graphics Onboard Onboard Onboard Onboard SIMATIC IPC87D (Box PC) Intel Xeon processor E3-168L v3 (4 cores, 8 threads,.3 (3.3) GHz, 8 MB cache, VT-d, AMT) Intel Core i3-4330te ( cores, 4 threads,.4 GHz, 4 MB cache, VT-x) Intel Celeron G180TE (C/T,. GHz, MB cache) GB, expandable up to 16 GB, optional ECC x PCI (40 mm) 1 x PCI (185 mm) x PCI-Express x16 / x4 (185 mm) Siemens IK PI 015 /793

15 Industrial PC Box PC General data Technical specifications (continued) Operating system without Preinstalled and activated / supplied on restore CD Windows Embedded Standard 009 (CF card GB, SSD, hard disk) Windows XP Professional MUI (SSD, hard disk) Windows Embedded Standard 7, 3-bit (CF card 4 GB, SSD, hard disk) Windows 7 Ultimate MUI, 3-bit (SSD, hard disk) Windows 7 Ultimate 3-bit MUI Windows 7 Ultimate 64-bit MUI Windows Embedded Standard 7, 3-bit (CFast >= 4 GB, SSD, hard disk) Windows Embedded Standard 7 Professional, 3-bit, MUI (CFast >= 8 GB, SSD, hard disk) Windows 7 Ultimate 3-bit MUI Windows 7 Ultimate 64-bit MUI Order separately RMOS3 V3.50 RMOS3 V Project-specific on request Linux 1) Other Interfaces Linux 1) Other PROFINET onboard - 3xRJ45 (CP 1616 compatible) onboard, optional PROFIBUS/MPI - 1 Mbps (CP 56-compatible), optional Linux 1) Other 3xRJ45 (CP 1616 compatible) onboard, optional 1 Mbps (CP 56-compatible) onboard, optional Windows 7 Ultimate 3-bit MUI Windows 7 Ultimate 64-bit MUI Linux 1) Other 3xRJ45 (CP 1616 compatible) onboard, optional 1 Mbps (CP 56-compatible) onboard, optional Ethernet x 10/100/1000 Mbps x 10/100/1000 Mbps x 10/100/1000 Mbps x 10/100/1000 Mbps USB 4 x USB.0-4x USB 3.0 4x USB3.0 Graphics 1 x DVI-D 1 x DVI-I (DVI and VGA) 1 x DisplayPort Drives 1 x DVI-I (DVI or VGA) 1 x DisplayPort Hard disks 1 x.5" (optional) 1 x.5" (optional) 1x3.5" x.5" RAID1/ x.5" 1 x DVI-I (DVI and VGA) 1 x DisplayPort 1x3.5" x.5" RAID1/ x.5" Solid-state drive 1 x.5" SATA (optional) 1 x.5" SATA (optional) 1 x.5" SATA (optional) 1 x.5" SATA (optional) FlashDrive 1 x CF externally accessible 1 x CFast externally accessible 1 x CFast internal, in place of HDD, SSD (optional) - - Optical drives - - DVD R/W DVD R/W Ambient conditions Vibration/shock load during operation Ambient temperature during operation SIMATIC IPC7D (Nanobox PC) 1 g / 15 g (with FlashDrive) 1 g / 15 g (with FlashDrive) 1g / 5g 1g / 5g 0 C 50 C (with FlashDrive) 0 C 40 C (with hard disk) SIMATIC IPC47D (Microbox PC) With maximum configuration: /55 ºC (with FlashDrive) ºC (with hard disk) SIMATIC IPC67D (Box PC) With maximum configuration: C /55 C (with 0/10 W load on USB, PCI(e) bus) SIMATIC IPC87D (Box PC) With maximum configuration: C /55 C (with 0/10 W load on USB, PCI(e) bus) Available - Not available 1) Suitable for specific Linux versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for Linux", see (Linux is a trademark of Linus Torvalds). More information Further information can be found on the Internet at: Information material can be ordered or downloaded from the Internet: /794 Siemens IK PI 015

16 Industrial PC Box PC SIMATIC IPC7D Overview SIMATIC IPC7D (Nanobox PC): The compact embedded IPC maintenance-free and dust-proof with versatile mounting Maximum compactness with approx. 1 liter enclosure volume or more with integrated industrial power supply for minimum space requirements in the control cabinet Maximum flexibility thanks four mounting options and interfaces on one side suitable for every installation situation Optimum variety of interfaces due to a large number of integrated interfaces such as a selectable serial port (RS 3/RS 485/CAN) and x teaming-capable Gigabit LAN Maximum industrial functionality due to closed enclosure for optimum dust protection and non-volatile retentive memory Further device options for optimum adaptation to the application with additional PCIe slot or RS 3 interfaces or digital I/O Benefits Flexible installation (rail, wall, portrait, side mounting); all mounting positions are allowed Minimum space requirements (installation space of approx. 1 liter or more; all interfaces on one side, integrated industrial power supply) Up to 50 C ambient temperature; dust protection due to closed enclosure LED for efficient self-diagnostics (e.g. using WinAC: Run/Stop, Error, Maintenance); optimized for headless operation Device options for optimum adaptation to the application (optional) - Simple expansion by means of a PCIe slot or - three additional RS3 interfaces or - four additional digital inputs and outputs each, 4 V DC High-performance data processing at low power consumption Intel Atom technology of the Power-Optimized family E6xx Power consumption from 8 W (low waste heat in protective enclosure/control cabinet) Wake-on-LAN for remote-controlled switching between standby and active state Support of Sleep States/SpeedStep (dynamic power adaptation depending on the required computing performance) Intel VT-x technology for virtualization High degree of industrial functionality and flexibility for implementing the embedded solution Flexible memory concepts: CompactFlash or more, Solid-State Drive, or hard drive Gbit Ethernet (teaming-capable); PROFINET with RT functionality (via Standard Ethernet) 4 high-speed USB.0 ports 1 RS3; alternatively as: RS485 or CAN (optional) Ready-to-run embedded bundles with WinAC RTX010 (F) and/or WinCC RT Advanced (optional) 51 KB retentive memory (MRAM), of which 18 KB can be written to within the buffer time (optional) Embedded and standard operating systems for selection: Windows Embedded Standard 009 and Windows XP Prof. MUI; Windows Embedded Standard 7 3 bit and Windows 7 MUI 3 bit Suited for Linux certificate for simple, secure implementation of proprietary Linux-based solutions High system availability in order to reduce the risk of potential failures and maintenance costs Maintenance-free since there are no rotating parts (fans, HDD) Battery-free operation even if retentive memory option is selected (with time-of-day synchronization over network) Comprehensive self-diagnostics thanks to pre-installed local diagnostics software SIMATIC IPC DiagBase High investment security in order to reduce engineering costs Long-term availability: Service & Support period of 8 10 years after market launch Siemens IK PI 015 /795

17 Industrial PC Box PC SIMATIC IPC7D Technical specifications 6ES7647-8A Processor Processor Intel Atom E6x0 Drives Hard disk CF or SSD or HD Memory Main memory 51 MB to GB Data areas and their retentivity retentive data area in total 51 kbyte (incl. times, counters, flags), max. Interfaces USB port 4x USB.0 high speed/high current free slots 1x PCIe x1 (optional) Connection for keyboard/mouse USB / USB serial interface COM1: 1 x RS3 or RS485 or CAN Video interfaces Graphics interface DVI-D Industrial Ethernet Industrial Ethernet interface x Fast Ethernet Mbps Yes Mbps Yes Monitoring functions Temperature Yes Watchdog Yes Status LEDs Yes 6ES7647-8A Degree and class of protection IP (at the front) 0 Standards, approvals, certificates Approval CE (industry), UL, culus CE mark Yes KC approval Yes Marine approval Germanischer Lloyd (GL) Yes American Bureau of Shipping Yes (ABS) Bureau Veritas (BV) Yes Det Norske Veritas (DNV) Yes Lloyds Register of Shipping (LRS) Yes Ambient conditions Operating temperature Ambient temperature during operation - during operating phase, min. 0 C - during operating phase, max. 50 C Operating systems Pre-installed operating system Yes Windows XP Prof. Yes without operating system Yes /796 Siemens IK PI 015

18 Industrial PC Box PC Ordering data Article No. Article No. SIMATIC IPC7D SIMATIC IPC7D 6ES A Atom E60 (600 MHz), 51 MB RAM, without drive, with CF slot, COM1: RS3, without operating system, device version: Base, DIN rail, 1 x DVI-D graphics interface x 10/100/1000 Mbps Ethernet RJ45 4 x USB V.0 (high current) CompactFlash slot 4 V DC industrial power supply Processors / memory configuration / NVRAM Atom E60 (600 MHz), A 51 MB RAM Atom E60 (600 MHz), B 51 MB RAM, NVRAM Atom E640 (1.0 GHz), 1 GB RAM E Atom E640 (1.0 GHz), 1 GB RAM, F NVRAM Atom E660 (1.3 GHz), GB RAM G Atom E660 (1.3 GHz), GB RAM, H NVRAM Drives Without drive, with CF slot 0 30 GB HDD SATA GB Solid-State Drive SATA 80 GB Solid-State Drive SATA 4 GB SIMATIC IPC CompactFlash 5 4 GB SIMATIC IPC CompactFlash 6 8 GB SIMATIC IPC CompactFlash 7 16 GB SIMATIC IPC CompactFlash 8 COM interface COM1: RS3 0 COM1: RS485 1 COM1: CAN Operating system Without operating system 0 Windows Embedded Standard preinstalled (CF from GB/SSD/HD) XP Prof. MUI preinstalled on SSD/HD Windows Embedded Standard 7 3 (3-bit) preinstalled (CF from 4 GB/SSD/HD) Windows 7 (3-bit) 4 MUI preinstalled on SSD/HD SIMATIC IPC7D 6ES A Software bundles Without RTX/HMI software A RTX: WinAC RTX 010 B RTX-F: WinAC RTX F 010 C HMI: WinCC RT Advanced 18 PT F HMI: WinCC RT Advanced 51 PT G HMI: WinCC RT Advanced 048 PT H HMI/RTX: RT 18 PT M HMI/RTX: RT 51 PT N HMI/RTX: RT 048 PT P HMI/RTX-F: RT 18 PT R HMI/RTX-F: RT 51 PT S HMI/RTX-F: RT 048 PT T Device versions Device version: Base line A Device version: PCIe (1 slot) B Device version: COM D (COM-4: RS3) Device version: IO E (4x dig. in/out each) Mounting accessories Standard mounting rail 1 Wall mounting Portrait mounting 3 Side mounting 4 Release for individual order variants: See releases in the ordering procedure. Accessories Cable strain relief set for IPC7D Packing unit: 5 units Dust protection set for IPC7D 6ES7648-1AA50-0XL0 6ES7648-1AA50-0XG0 More information Further information can be found on the Internet at: Siemens IK PI 015 /797

19 Industrial PC Box PC SIMATIC IPC47D Overview SIMATIC IPC47D (Microbox PC): The powerful embedded IPC maintenance-free with versatile configuration Ready-to-run, complete solutions (software is already installed and preconfigured) for visualization and automation in connection with WinCC RT Advanced and/or WinAC RTX: Ultra-compact Maintenance-free Third generation Intel Core i technology Benefits High data processing speed for high productivity Up to Core I 7, fan-free DDR3 memory technology up to 8 GB Maximum compactness and ruggedness for use directly on the machine Low mounting depth, ambient temperature up to 55 C Upright mounting as second standard mounting position (ambient temperature 50 C) Solid State Drive (SSD) (50 GB high endurance or 80 GB standard, optional), SATA hard disk, or up to CFast cards with 16 GB High degree of industrial functionality and flexibility for implementing embedded solutions Flexible memory concepts (e.g. mass storage units possible) x LAN 10/100/1 000 Mbit/s connections; teaming-capable Onboard PROFIBUS or PROFINET interface (optional) 4 x high-speed USB 3.0 ports; serial interfaces (nd interface is optional) Flexible installation with mounting options (rail, wall, front upright mounting) Simple expansion capability (up to PCIe slots) On/off switch High system availability in order to reduce the risk of potential failures and maintenance costs Maintenance-free since no rotating parts (fans, hard disks) and operation without battery possible 51 KB NVRAM can be written by WinAC RTX Front LED for efficient self-diagnostics; optimized for headless operation through special BIOS properties SIMATIC software system-tested High investment security in order to reduce engineering costs Long-term availability: Service and support period of 8 to 10 years after market launch Installation and interface compatibility with predecessor versions as of 004 /798 Siemens IK PI 015

20 Industrial PC Box PC SIMATIC IPC47D Technical specifications Supply voltage Type of supply voltage Supply voltage Processor Processor Drives Hard disk Memory Main memory Interfaces PROFIBUS/MPI USB port free slots Connection for keyboard/mouse serial interface Video interfaces Graphics interface 6AG V DC 4 V Intel Celeron Processor 87E (1.5MB Cache, 1.40 GHz); Intel Core i3-317ue Processor (3MB Cache, 1.60 GHz); Intel Core i7-3517ue Processor (4MB Cache, up to.80 GHz).5" SATA hard disk, at least 50 GB 1 GB to 8 GB, ECC optional Onboard, isolated, max. 1 Mbit/s, CP5611-compatible 4x USB 3.0 high speed/high current 1xPCIe (x4), 1xPCIe (x1) USB / USB 1 x RS3; x RS3 (optional); CAN (optional) 1x DisplayPort and 1x DVI-I; 1x VGA via adapter cable (optional) PROFINET IO Number of PROFINET interfaces 1; 3 ports (incl. switch) Industrial Ethernet Industrial Ethernet interface x Fast Ethernet Mbps Yes Mbps Yes Monitoring functions Temperature Yes Watchdog Yes Status LEDs Yes Degree and class of protection IP (at the front) 0 6AG Standards, approvals, certificates Approval CE, culus (508), C-Tick CE mark Yes KC approval Yes culus Yes EMC CE, EN 550A, EN , EN EN Yes Marine approval Germanischer Lloyd (GL) Yes American Bureau of Shipping (ABS) Yes Bureau Veritas (BV) Yes Det Norske Veritas (DNV) Yes Lloyds Register of Shipping (LRS) Yes Ambient conditions Operating temperature Ambient temperature during 0 C to +55 C operation - during operating phase, min. 0 C - during operating phase, max. 55 C Relative humidity Relative humidity Tested to DIN IEC , DIN IEC , DIN IEC : 5% to 80% at 5 C (no condensation) Vibrations Vibration load in operation Tested to DIN IEC : 10 Hz to 58 Hz: mm, 58 Hz to 00 Hz: 9.8 m/s² (1 g) Shock testing Shock load during operation Tested to DIN IEC : 50 m/s² (5g), 30 ms, 100 shocks Operating systems Operating system Pre-installed operating system Software SIMATIC Software Windows 7 Ultimate (Multi Language) 3-bit/64-bit, Windows Embedded Standard 7 3-bit/64-bit Yes Optionally with pre-installed software bundle SIMATIC WinCC RT Advanced / WinAC RTX Siemens IK PI 015 /799

21 Industrial PC Box PC SIMATIC IPC47D Ordering data Article No. Article No. SIMATIC IPC47D (Box PC) 1) ) 6AG Processor and fieldbus: Celeron U87E 0 (1C/1T, 1.4 GHz, 1.5 MB cache); x Gigabit Ethernet (IE/PN) Celeron U87E (1C/1T, 1.4 GHz, MB cache); x Gigabit Ethernet (IE/PN); PROFIBUS DP1 Celeron U87E (1C/1T, 1.4 GHz, 1.5 MB cache); x Gigabit Ethernet (IE/PN); CAN interface Core i3-317ue (C/4T, 1.6 GHz, 3 3 MB cache); x Gigabit Ethernet (IE/PN) Core i3-317ue (C/4T, 1.6 GHz, 4 3 MB cache); x Gigabit Ethernet (IE/PN); PROFIBUS DP1 Core i3-317ue 5 (C/4T, 1.6 GHz, 3 MB cache); 1 x Gigabit Ethernet (IE/PN); 1 x PROFINET (IRT, 3 ports) Core i7-3517ue 6 (C/4T, 1.7 (.8) GHz, 3 MB cache); x Gigabit Ethernet (IE/PN) (optional ECC only here) Core i7-3517ue (C/4T, 1.7 (.8) 7 GHz, 3 MB cache); x Gigabit Ethernet (IE/PN); PROFIBUS DP1 Core i7-3517ue (C/4T, (.8) GHz, 3 MB cache); 1 x Gigabit Ethernet (IE/PN); 1 x PROFINET (IRT, 3 ports) Mounting accessories: without mounting accessories A DIN rail mounting B Wall mounting D Portrait mounting E Work memory/nvram/ecc: 1 GB A GB B 4 GB C 8 GB D 4 GB with ECC (only with Core i7, G x Gigabit Ethernet (IE/PN)) 8 GB with ECC (only with Core i7, H x Gigabit Ethernet (IE/PN)) 1 GB and NVRAM J GB and NVRAM K 4 GB and NVRAM L 8 GB and NVRAM M 4 GB with ECC and NVRAM (only N with Core i7, x Gigabit Ethernet (IE/PN)) 8 GB with ECC and NVRAM (only P with Core i7, x Gigabit Ethernet (IE/PN)) Expansions/interface: One RS 3, without PCIe 0 One RS 3 and one PCIe 1 One RS 3 and two PCIe Second RS 3, without PCIe 3 Second RS 3 and one PCIe 4 Second RS 3 and second PCIe 5 Operating system: Without operating system 0 Windows Embedded Standard 7 3 Professional, 3-bit, MUI Windows Embedded Standard 7 4 SP1, English, 3-bit Windows Embedded Standard 7 5 SP1, English, 64-bit Windows 7 Ultimate SP1, 3-bit, 6 MUI (Eng, Ger, Fr, It, Sp) Windows 7 Ultimate SP1, 64-bit, 7 MUI (Eng, Ger, Fr, It, Sp) SIMATIC IPC47D (Box PC) 1) ) 6AG Mass storage, externally accessible: Without external mass storage 0 CFast GB 1 Without operating system CFast 4 GB (only optionally with operating system if no internal mass storage) CFast 8 GB 3 (only optionally with operating system if no internal mass storage) CFast 16 GB 4 (only optionally with operating system if no internal mass storage) Internal mass storage: Without internal mass storage A CFast GB, without software B CFast 4 GB, without software C CFast 8 GB, without software D CFast 16 GB, without software E SSD 50 GB High Endurance (SLC) G SSD 80 GB Standard H HDD 50 GB K SSD 160 GB Standard P SIMATIC software preinstalled (bundles, only with Windows Embedded Standard 7): Without SIMATIC software A WinAC RTX 010 3) B WinCC RT Advanced, 18 PT C WinCC RT Advanced, 51 PT D WinCC RT Advanced, 048 PT E WinCC RT Advanced, PT F WinCC RT Advanced 18 PT, J WinAC RTX 010 3) WinCC RT Advanced 51 PT, K WinAC RTX 010 3) WinCC RT Advanced 048 PT, L WinAC RTX 010 3) WinCC RT Advanced PT, M WinAC RTX 010 3) WinAC RTX F 010 3) N WinCC RT Advanced 18 PT, P WinAC RTX F 010 3) WinCC RT Advanced 51 PT, Q WinAC RTX F 010 3) WinCC RT Advanced 048 PT, R WinAC RTX F 010 3) WinCC RT Advanced PT, S WinAC RTX F 010 3) WinCC RT Professional Client/ Y single-user station 18 PT Power supply: 4VDC 0 industrial power supply 4 V DC and TPM 8 (not for China and Russia) 1) "Built to order" versions with a delivery time of max. 15 working days and with identified repair, if not preferred type. ) For an up-to-date overview, see the SIMATIC PC online configurator at: 3) Only with "main memory and NVRAM". Note: Bundles with SIMATIC software only with Windows Embedded Standard 7, main memory and NVRAM (with RTX and RTX F), and CFast mass storage of 4 GB or more / SSD. /800 Siemens IK PI 015

22 Overview IPC67D with DVD drive SIMATIC IPC67D (Box PC): The high-end IPC with maximum performance, functional scope and expansion capability It offers: Maximum performance in the smallest space Intel Xeon technology Benefits Maximum system performance for complex measuring, control and visualization tasks Intel processors: Xeon, Core i3 or Celeron; in each case with 4 or cores, with turbo-boost technology and AMT (Xeon) and hyper-threading (Xeon, i3) Intel DH8C6 PCH Platform Controller Hub (PCH) DDR memory technology up to 16 GB RAM Intel HD 4600 (Xeon, i3) graphics for high graphics performance PCI Express x16 slot for x16 graphics card support SATA hard disks with up to 500 GB capacity and NCQ technology (Native Command Queuing) for larger data volumes Highly compact design for space-saving and flexible installation Compact housing design (volume 6 liters) Flexible installation in many different positions with mounting brackets or portrait installation kits Free expansion slots: x PCI or x PCIe or 1 x PCIe and 1 x PCI 3 X PROFINET interfaces onboard (optional, IRT-capable, 3-port, switching-enabled, CP 1616-compatible) 1 x PROFIBUS interface onboard (optional, CP 56-compatible) x LAN 10/100/1000 Mbit/s connections (Gigabit Ethernet with teaming capability), PROFINET RT-compatible 4 x USB 3.0 (SuperSpeed) DisplayPort and DVI-I interface (for VGA or DVI-D monitors) Industrial PC Box PC SIMATIC IPC67D Rugged design for direct installation in the machine Maximum processor performance up to ambient temperature of 55 C High shock/vibration resistance in all possible mounting positions High EMC for safe operation SATA Solid-State Drive (SSD) with 40 GB for high reliability and speed Strain relief for all cables/connectors High system availability, fast startup, maintenance and servicing High degree of data security thanks to mirror disk system (RAID1, optional) or Solid State Drive (SSD, optional) ECC memory (optional, for 1-bit error correction) MB battery-buffered SRAM, 18 KB of which can be used as memory for retentive WinAC RTX data Active Management Technology (Intel AMT) for Xeon versions (remote access to the device, also in shut-down state) CMOS buffer battery accessible from outside, replaceable during operation. Status can be scanned by software. 4 LEDs 1 x power and 3 x applications (WinAC) Operating system preinstalled, ready to run, and already activated (eliminates need for usual product activation via the Internet or by telephone) Following system failure, fast restoration of hard disk contents to as-delivered status using supplied recovery and restore CD Worldwide service and support Cost reductions through high investment security Platform with long-term stability and embedded Intel components Availability of 3 to 6 years, then guaranteed availability of spare parts for further 5 years Part of the scalable Box PC range with identical performance features and footprint System-tested with SIMATIC components Certification for worldwide marketing (e.g.: culus) Installation compatible for all device generations, software compatible with predecessor model Siemens IK PI 015 /801

23 Industrial PC Box PC SIMATIC IPC67D Technical specifications General features Processor Main memory Free slots for expansions Operating system Operating system Supply voltage Drives Optical drives SATA hard disks SIMATIC IPC67D Intel Xeon Processor E3-168L v3 (4C,.3 (3.3) GHz, HT, 8 MB cache, HT, VT-d, AMT) Intel Core i3-4330te (C,.4 GHz, 4 MB cache, HT, VT-x) Intel Celeron G180TE (C,. GHz, MB cache) GB; DDR3 1600, DIMM; expandable up to 16 GB ( memory receptacles); ECC memory 8/16 GB optional 1 x PCI (185 mm) and 1 x PCI (185 mm) or 1 x PCI (185 mm) and 1 x PCIe x16 (185 mm) x PCI-Express (x16/x4, 185/185 mm) Without Windows 7 Ultimate Multi-Language 3-bit or 64-bit variant, SP1 100 V /30 V / 40 V AC (widerange) 50/60 Hz; optional 4 V DC SATA DVD±RW/DL Drive, optional (Depth increases from 80 mm to 100 mm) None; 50 GB, 500 GB, RAID1 ( x 50 GB) Solid state drive 40 GB SATA.5" Approvals culus508, culus1950, FCC Class A Ports DisplayPort 1 x DisplayPort DVI-I 1 x (analog OR digital) VGA Via adapter cable, DVI-I to VGA adapter (available as accessory) Dual Monitor Via DisplayPort and DVI-I Parallel interface PC slot cover (available as accessory) Serial interface 1 x COM1 PROFIBUS/MPI 1 Mbit/s (isolated, CP 56-compatible, optional) PROFINET 3 x RJ45 (CP 1616-compatible, optional) 1) USB 4 x USB 3.0, SuperSpeed; x USB.0 (optional) Ethernet x Gigabit Ethernet (IE, PN, RJ45, teaming-capable) 1) Note: The PROFINET and PROFIBUS options are supplied with MB batterybacked SRAM SIMATIC IPC67D Monitoring functions Temperature and Watchdog Onboard Status LEDs 4 LEDs Ambient conditions Degree of protection IP0 according to EN 6059 (front/rear) Vibration load during operation ) Hz: 0.75 mm, Hz: 9.8 m/s (approx. 1 g) with DVD operation: Hz: mm, Hz:.5 m/s (approx. 0.5 g) Shock load during operation 3) Tested according to DIN IEC 68--9: 50 m/s (5 g), with DVD operation: 50 ms, 11 ms (5 g) Relative humidity during operation 5 % to 80 % at 5 C (no condensation); Relative humidity during transport / storage Electromagnetic compatibility (EMC) ) No vibration permitted when burning DVDs; 3) No shock permitted when burning DVDs 5% to 95% at 5 C (no condensation) Emitted interference EN , EN Class D, EN ; FCC Class A Immunity to interference to conducted interference on the supply cables on signal cables to discharge of static electricity to high-frequency radiation ± kv (IEC , burst), ± 1 kv (IEC , surge symm.), ± kv (IEC , surge asymm.) ± 1 kv (IEC , burst, length < 3 m), ± kv (IEC , burst, length > 3 m), ± kv (IEC , surge, length > 30 m) ± 6 kv contact discharge (IEC ), ± 8 kv air discharge (IEC ) 10 V/m 80% AM, MHz and GHz (IEC ); 1 V/m 80% AM,.0-.7 GHz (IEC ), 10 V, 10 khz to 80 MHz (IEC ) to magnetic fields 100 A/m, 50/60 Hz (IEC ) Ambient temperature during operation Dimensions Device dimensions (W x H x D) in mm Weight 5 to 45 C (maximum configuration); 5 to 50 C (up to 0 W load on PCI bus), 5 to 55 C (up to 10 W load on PCI bus) 31 x 301 (incl. mounting rail) x 105 without DVD drive: 31 x 301 (incl. mounting rail) x 80 approx. 7 kg /80 Siemens IK PI 015

24 Industrial PC Box PC Ordering data Article No. Article No. SIMATIC IPC67D SIMATIC IPC67D 1) 6AG HD graphics onboard (Xeon, i3: HD4600); x Gigabit Ethernet (IE/PN) RJ45; 4 x USB V3.0; 1x serial (COM1); RAID controller onboard; watchdog, temp./fan monitoring; Processor: Core i3-4330te (C/4T,.4 GHz, 4 MB cache, VT-x); D Core i3-4330te (C/4T,.4 GHz, E 4 MB cache, VT-x); PROFIBUS/MPI (CP 56-compatible); MB battery-backed SRAM; Core i3-4330te (C/4T,.4 GHz, F 4 MB cache, VT-x); PROFINET (IRT, 3 ports, CP 1616-compatible); MB battery-backed SRAM; Xeon E3-168Lv3 (4C/8T,.3 (3.3) G GHz, 8 MB cache, VT-d, AMT); Xeon E3-168Lv3 (4C/8T,.3 (3.3) H GHz, 8 MB cache, VT-d, AMT); PROFIBUS/MPI (CP 56-compatible); MB battery-backed SRAM; Xeon E3-168Lv3 (4C/8T,.3 (3.3) J GHz, 8 MB cache, VT-d, AMT); PROFINET (IRT, 3 ports, CP 1616-compatible); MB battery-backed SRAM; Drives 50 GB HDD SATA; A 50 GB HDD SATA; DVD+/-RW; B 500 GB HDD SATA; D 500 GB HDD SATA; DVD+/-RW; E RAID1 x 50 GB SATA (.5"); G RAID1 x 50 GB SATA (.5"); H DVD+/-RW; Solid-state drive 40 GB; M Solid-state drive 40 GB; 50 GB N HDD SATA (.5"); Solid-state drive 40 GB; 50 GB P HDD SATA (.5"); DVD+/-RW; Memory configuration GB DDR DIMM; 1 4 GB DDR DIMM; 8 GB DDR DIMM; 3 16 GB DDR DIMM; 4 8 GB DDR DIMM; ECC; 5 16 GB DDR DIMM; ECC; 6 Expansion 1 (HW) x PCI; 0 1 x PCIe (x16); 1 x PCI; 1 1 x PCIe (x16); 1 x PCIe (x4); Expansion (HW) Without expansions (HW); 0 x USB in addition 1 (1 slot occupied); COM; LPT (1 slot occupied); x USB in addition; COM; LPT 3 ( slots occupied); SIMATIC IPC67D 1) 6AG Operating system Windows 7 Ultimate, 3-bit SP1, A MUI (Eng, Ger, Fr, It, Sp); Windows 7 Ultimate, 64-bit SP1, MUI (Eng, Ger, Fr, It, Sp); B Without X expansions (SW) SIMATIC IPC DiagMonitor V4.x A enclosed; SIMATIC IPC Image & Partition B Creator V3.x enclosed; SIMATIC IPC DiagMonitor V4.x, C Image & Partition Creator V3.x enclosed; Without X TPM module Y (not for China and Russia); Country-specific version/ power supply 110/30 V AC industrial 0 power supply with NAMUR; European power cable; 110/30 V AC industrial power 1 supply with NAMUR; UK power cable; 110/30 V AC industrial power supply with NAMUR; power cable for Switzerland; 110/30 V AC industrial power 3 supply NAMUR; US power cable; 110/30 V AC industrial power 4 supply NAMUR; power cable for Italy; 110/30 V AC industrial power 5 supply with NAMUR; power cable for China 4 V DC industrial power supply; 6 1) For an up-to-date overview, see the SIMATIC PC online configurator at: Accessories Memory expansion GB DDR SDRAM, DIMM 4 GB DDR SDRAM, DIMM 8 GB DDR SDRAM, DIMM 8 GB DDR SDRAM, DIMM, ECC Assembly kit for portrait mounting Upward or downward interface outlet Interface outlet to the front SIMATIC PC graphics adapter cable DVI-I acc. to VGA, 50 mm long SIMATIC PC power cable for Box PC and Panel PC, 30 V AC, angled, 3 m for Germany, France, Spain, the Netherlands, Belgium, Sweden, Austria, Finland for United Kingdom For Switzerland For the USA For Italy For China 6ES7648-AJ50-0MA0 6ES7648-AJ60-0MA0 6ES7648-AJ70-0MA0 6ES7648-AJ70-1MA0 6ES7648-1AA10-1YA0 6ES7648-1AA10-1YB0 6ES7648-3AB00-0XA0 6ES7900-1AA00-0XA0 6ES7900-1BA00-0XA0 6ES7900-1CA00-0XA0 6ES7900-1DA00-0XA0 6ES7900-1EA00-0XA0 6ES7900-1FA00-0XA0 More information Additional information is available on the Internet at: Siemens IK PI 015 /803

25 Industrial PC Box PC SIMATIC IPC87D Overview SIMATIC IPC87D (Box PC): The high-end IPC with maximum performance, functional scope and expansion capability It offers: Maximum performance and high expandability with Intel Xeon technology Benefits Maximum system performance for complex measuring, control and visualization tasks Intel processors: Xeon, Core i3 or Celeron; in each case with cores, with turbo-boost technology and AMT (Xeon) and hyper-threading (Xeon, i3) Intel DH8C6 PCH Platform Controller Hub (PCH) DDR memory technology up to 16 GB RAM Intel HD 4600 (Xeon, i3) graphics for high graphics performance PCI Express x16 slot for x16 graphics card support SATA hard disks with up to 500 GB capacity and NCQ technology (Native Command Queuing) for a larger data volume High flexibility and expandability Flexible installation in many different positions with mounting brackets or portrait assembly kit Vacant expansion slots: 3 x PCI, 1 x PCIe Express (x16) and 1 x PCIe (x4) 3 x PROFINET interfaces onboard (optional, IRT-capable, 3-port, switching-enabled, CP1616-compatible) 1 x PROFIBUS interface onboard (optional, CP56-compatible) RAID1 controller onboard (no occupation of a PC slot) x LAN 10/100/1000 Mbit/s connections (Gigabit Ethernet with teaming capability), PROFINET RT-compatible 4 x USB-3.0 ports (SuperSpeed) DisplayPort and DVI-I interface (for VGA and/or DVI-D monitors) Rugged design for direct installation in the machine Maximum processor performance up to an ambient temperature of 55 C High shock/vibration resistance in all possible mounting positions High EMC for safe operation SATA Solid-State Drive (SSD) with 40 GB for high reliability and speed Strain relief for all cables/connectors High system availability, fast startup, maintenance and servicing High degree of data security thanks to mirror disk system (RAID1, optional) or Solid State Drive (SSD, optional) ECC memory (optional, for 1-bit error correction) MB battery-backed SRAM, of which 18 KB can be used as memory for retentive WinAC RTX data Active Management Technology (Intel AMT) for Xeon versions (remote access to the device, also in shut-down state) Externally accessible CMOS backup battery, replaceable during operation, status can be scanned by software 4 LEDs 1 x power and 3 x applications (WinAC) Operating system preinstalled, ready to run, and already activated (eliminates need for usual product activation via the Internet or by telephone) Following system failure, fast restoration of hard disk contents to factory status using supplied recovery and restore DVD Worldwide service and support Cost reductions through high investment security Long-term platform with Intel embedded components Availability of 3 to 6 years, then guaranteed availability of spare parts for further 5 years Part of the scalable Box PC range with identical performance features and footprint System-tested with SIMATIC hardware and software Certification for worldwide marketing (e.g.: culus) Installation compatible for all device generations, software compatible with predecessor model /804 Siemens IK PI 015

26 Industrial PC Box PC SIMATIC IPC87D Technical specifications General features Processor Main memory Free slots for expansions Operating system Operating system Supply voltage Drives Optical drives SATA hard disks SIMATIC IPC87D Intel Xeon Processor E3-168L v3 (4C,.3 (3.3) GHz, HT, 8 MB cache, HT, VT-d, AMT) Intel Core i3-4330te (C,.4 GHz, 4 MB cache, HT, VT-x) Intel Celeron G180TE (C,. GHz, MB cache) GB; DDR3 1600, DIMM; expandable up to 16 GB ( memory receptacles); ECC memory 8/16 GB optional x PCI (40 mm) 1 x PCI (185 mm) x PCI-Express (x16/x4, 185/185 mm) Without Windows 7 Ultimate Multi-Language 3-bit or 64-bit variant, SP1 100 V /30 V / 40 V AC (widerange) 50/60 Hz; optional 4 V DC DVD±RW/DL SATA, optional (depth increases from 155 mm to 179 mm) None; 50 GB, 500 GB, RAID1 ( x 50 GB) Solid state drive 40 GB SATA.5" Approvals culus508, culus1950, FCC Class A Ports DisplayPort 1 x DisplayPort DVI-I 1 x (analog OR digital) VGA Via adapter cable, DVI-I to VGA adapter (available as accessory) Dual Monitor Via DisplayPort and DVI-I Parallel interface PC slot cover (available as accessory) Serial interface 1 x COM1 PROFIBUS/MPI 1 Mbit/s (isolated, CP 56-compatible, optional) PROFINET 3 x RJ45 (CP 1616-compatible, optional) 1) USB 4 x USB 3.0, SuperSpeed; x USB.0 (optional) Ethernet x Gigabit Ethernet (IE, PN, RJ45, teaming-capable) Monitoring functions Temperature and Watchdog Onboard Status LEDs 4 LEDs SIMATIC IPC87D Ambient conditions Degree of protection IP0 according to EN 6059 (front/rear) Vibration load in operation ) Hz: 0.75 mm, Hz: 9.8 m/s (approx. 1 g) with DVD operation: Hz: mm, Hz:.5 m/s (approx. 0.5 g) Shock load during operation 3) Tested according to DIN IEC 68--9: 50 m/s (5 g), with DVD operation: 50 ms, 11 ms (5 g) Relative humidity during operation 5 % to 80 % at 5 C (no condensation); Relative humidity during transport / storage Electromagnetic compatibility (EMC) 5% to 95% at 5 C (no condensation) Emitted interference EN , EN Class D, EN ; FCC Class A Immunity to interference to conducted interference on the supply cables on signal cables to discharge of static electricity to high-frequency radiation to magnetic fields Ambient temperature during operation ± kv (IEC , burst), ± 1 kv (IEC , surge symm.), ± kv (IEC , surge asymm.) ± 1 kv (IEC , burst, length < 3 m), ± kv (IEC , burst, length > 3 m), ± kv (IEC , surge, length > 30 m) ± 6 kv contact discharge (IEC ), ± 8 kv air discharge (IEC ) 10 V/m 80% AM, MHz and GHz (IEC ); 1 V/m 80% AM,.0-.7 GHz (IEC ), 10 V, 10 khz to 80 MHz (IEC ) 100 A/m, 50/60 Hz (IEC ) 5 to 45 C maximum configuration); 5 to 50 C (up to 0 W load on PCI bus), 5 to 55 C (up to 10 W load on PCI bus) Dimensions Device dimensions (W x H x D) in mm 31 x 301 (incl. mounting rail) x 179 without DVD drive: 31 x 301 (incl. mounting rail) x 155 Weight approx. 8 kg 1) Note: The PROFINET and PROFIBUS options are supplied with MB battery-backed SRAM ) No vibration permitted when burning DVDs; 3) No shock permitted when burning DVDs Siemens IK PI 015 /805

27 Industrial PC Box PC SIMATIC IPC87D Ordering data Article No. Article No. SIMATIC IPC87D 1) 6AG HD graphics onboard (Xeon, i3: HD4600); x Gigabit Ethernet (IE/PN) RJ45; 4 x USB V3.0; 1x serial (COM1); RAID controller onboard; watchdog, temp./fan monitoring; Processor: Celeron G180TE A (C/T,. GHz, MB cache) Celeron G180TE B (C/T,. GHz, MB cache); PROFIBUS/MPI (CP 56-compatible); MB battery-backed SRAM ) Celeron G180TE C (C/T,. GHz, MB cache); PROFINET (IRT, 3 ports, CP 1616-compatible); MB battery-backed SRAM Core i3-4330te (C/4T,.4 GHz, D 4 MB cache, VT-x) Core i3-4330te (C/4T,.4 GHz, E 4 MB cache, VT-x); PROFIBUS/MPI (CP 56-compatible); MB battery-backed SRAM ) Core i3-4330te (C/4T,.4 GHz, F 4 MB cache, VT-x); PROFINET (IRT, 3 ports, CP 1616-compatible); MB battery-backed SRAM Xeon E3-168Lv3 (4C/8T,.3 (3.3) G GHz, 8 MB cache, VT-d, AMT) Xeon E3-168Lv3 (4C/8T,.3 (3.3) H GHz, 8 MB cache, VT-d, AMT); PROFIBUS/MPI (CP 56-compatible); MB battery-backed SRAM ) Xeon E3-168Lv3 (4C/8T,.3 (3.3) J GHz, 8 MB cache, VT-d, AMT); PROFINET (IRT, 3 ports, CP 1616-compatible); MB battery-backed SRAM Drives 50 GB HDD SATA; A 50 GB HDD SATA; DVD+/-RW; B 500 GB HDD SATA; D 500 GB HDD SATA; DVD+/-RW; E RAID1 x 50 GB SATA (.5"); G RAID1 x 50 GB SATA (.5"); H DVD+/-RW Solid-state drive 40 GB; M Solid-state drive 40 GB; 50 GB N HDD SATA (.5"); Solid-state drive 40 GB; 50 GB P HDD SATA (.5"); DVD+/-RW; Memory configuration GB DDR DIMM; 1 4 GB DDR DIMM; 8 GB DDR DIMM; 3 16 GB DDR DIMM; 4 8 GB DDR DIMM; ECC; 5 16 GB DDR DIMM; ECC; 6 Expansions (HW) 1 x PCIe (x16); 1 x PCIe (x4); 0 3 x PCI Expansion (HW) Without expansions (HW); 0 x USB in addition 1 (1 slot occupied); COM; LPT (1 slot occupied); x USB in addition; COM; LPT 3 ( slots occupied); SIMATIC IPC87D 1) 6AG Operating system Windows 7 Ultimate, 3-bit SP1, A MUI (Eng, Ger, Fr, It, Sp); Windows 7 Ultimate 64-bit SP1, B MUI (Eng, Ger, Fr, It, Sp); Without X expansions (SW) SIMATIC IPC DiagMonitor V4.x A enclosed; SIMATIC IPC Image & Partition B Creator V3.x enclosed; SIMATIC IPC DiagMonitor V4.x, C Image & Partition Creator V3.x enclosed; Without X TPM module Y (not for China and Russia); Country-specific version/ power supply 110/30 V AC industrial power 0 supply with NAMUR; European power cable; 110/30 V AC industrial power 1 supply with NAMUR; UK power cable; 110/30 V AC industrial power supply with NAMUR; power cable for Switzerland; 110/30 V AC industrial power 3 supply NAMUR; US power cable; 110/30 V AC industrial power 4 supply NAMUR; power cable for Italy; 110/30 V AC industrial power 5 supply with NAMUR; power cable for China 4 V DC industrial power supply; 6 1) For an up-to-date overview, see the SIMATIC PC online configurator at: ) Expected start of delivery: nd quarter 014 Accessories Memory expansion GB DDR SDRAM, DIMM 4 GB DDR SDRAM, DIMM 8 GB DDR SDRAM, DIMM 8 GB DDR SDRAM, DIMM, ECC Assembly kit for portrait mounting Upward or downward interface outlet Interface outlet to the front SIMATIC PC graphics adapter cable DVI-I acc. to VGA, 50 mm long SIMATIC PC power cable for Box PC and Panel PC, 30 V AC, angled, 3 m for Germany, France, Spain, the Netherlands, Belgium, Sweden, Austria, Finland for the United Kingdom For Switzerland For the USA For Italy For China 6ES7648-AJ50-0MA0 6ES7648-AJ60-0MA0 6ES7648-AJ70-0MA0 6ES7648-AJ70-1MA0 6ES7648-1AA30-1YA0 6ES7648-1AA30-1YB0 6ES7648-3AB00-0XA0 6ES7900-1AA00-0XA0 6ES7900-1BA00-0XA0 6ES7900-1CA00-0XA0 6ES7900-1DA00-0XA0 6ES7900-1EA00-0XA0 6ES7900-1FA00-0XA0 More information Additional information is available on the Internet at: /806 Siemens IK PI 015

28 Overview SIMATIC Panel PCs are suitable thanks to their high industrial compatibility for use in control cabinets, consoles and control panels, as well as directly on the machine. Typical areas of application can be found in both factory and process automation. There is a broad range of robust, high-performance SIMATIC Panel PCs available for different requirements. Shared industrial functionality High-quality components and modules with a high MTBF (mean time between failure), which also ensure 4-hour operation in the extended temperature range. High swing/shock capacity of the devices through special hard-disk suspensions, locked connectors and card retainers Rugged housing model with high electromagnetic compatibility (EMC) and integrated industrial power supplies (also as per NAMUR) Service-friendly device design Bright, brilliant displays in different sizes up to 19" Same front panel mounting dimensions and uniform front design across all device families Rugged fronts protected from dust, humidity and chemical substances (front-side IP65 / NEMA 4 degrees of protection) SIMATIC IPC77: The embedded Nanopanel PC maintenance-free and compact with displays starting from 7" High degree of flexibility for selecting rugged widescreen fronts from 7" to 19" for a more freely configurable display area High resolution, large viewing angle, and up to 100% dimmable backlighting for a brilliant display with optimized power consumption Absolutely maintenance-free due to the use of CompactFlash or SSD as mass storage and fanless operation up to 50 C ambient temperature Maximum industrial functionality due to non-volatile retentive memory (option) Ready-to-use embedded bundles with visualization and/or control software Industrial PC SIMATIC Panel PC General data SIMATIC IPC477D: The powerful embedded Panel PC maintenance-free with versatile configuration Compact design High performance with highly compact design and ruggedness Flexible expansion using a PCIe I/O card (optional) No rotating parts (without fan and hard disk) High security due to use of the operating system Windows Embedded Standard 7 Ready-to-use devices with optionally preinstalled software HMI: Innovative HMI software WinCC RT Advanced (including logging and recipes) RTX: with real-time capable software PLC WinAC RTX Retentive memory on-board (NV-RAM, usable with WinAC RTX) SIMATIC HMI IPC477C: The powerful embedded Panel PC maintenance-free with versatile configuration Compact design High performance with highly compact design and ruggedness (optional) Also available as PRO version (all-round IP65 degree of protection) with 15" and 19" Touch displays No rotating parts (without fan and hard disk) High security due to Microsoft Windows Embedded Standard 009 or Windows Embedded Standard 7 operating systems Ready-to-use devices with optionally preinstalled software - HMI: Innovative HMI software WinCC flexible (incl. archives and recipes) - RTX: with real-time capable software PLC WinAC RTX Retentive memory on board (NV-RAM, usable with WinAC RTX) SIMATIC HMI IPC577: Industrial functionality and openness at an attractive price Full PC openness and performance boost with Intel Core Duo processors Rugged design for industrial use Can be expanded using a PCI slot and additional interfaces More rugged due to SSD (solid-state drive) or CompactFlash The configurator (best-fit for the customer) makes ordering more flexible Compact design SIMATIC HMI IPC677: The high-end Panel PC with maximum performance, functional scope and expansion capability Rugged, expandable industrial PC with different front panels Rugged design for industrial use Complete PC openness Optional PROFIBUS or PROFINET onboard All processors with dual core Siemens IK PI 015 /807

29 Industrial PC SIMATIC Panel PC General data Benefits High degree of industrial capability The entire construction is designed for purely industrial use. Thus, for example, a special vibration-absorbing suspension of the hard disk ensures operational reliability, even at high mechanical loads. This makes that the SIMATIC Panel PCs are designed for a vibration load of 1 g and a shock load of 5 g. Performance Thanks to the use of the latest Intel processors from ULV (Ultra Low Voltage) to Intel Core technology, SIMATIC Panel PCs are flexibly scalable for your application. Scalable computing power Highest computing power Latest Intel processor technology Core i, Dual Core, ULV, Atom Investment security High component continuity and guaranteed availability of spare parts for up to 5 years after product phase-out are ensured e.g. through the development and production of our own motherboards. This enables long-lasting machine concepts without renewed engineering effort. Service-friendly device design Upgrades and exchange of components are easy thanks to the device design. Integrated interfaces The different already-integrated interfaces allow for various communication and expansion options. Many models are already equipped with Gigabit Ethernet and PROFIBUS DP/MPI interface. Expandability Depending on the model, ISA, PCI, PCI Express, PC/104 Plus and PC/104 slots are available for individual expandability. This enables the further use of existing and new expansion cards. Compact dimensions Considering the desired expandability, SIMATIC Panel PCs have an extremely low mounting depth and can thus be used in very narrow installation locations. Options Various options enable an individual solution for your industrial application. Thus, the operator control unit can be operated separately from the computer unit by up to 30 m. The direct control key module increases the operating safety in that it can be used to run the process independently of the operating system and without delay directly on PROFIBUS DP/MPI. Individually expandable system availability RAID1 configuration - high system stability through redundant data management SIMATIC IPC DiagMonitor Monitoring of the operating states and early detection of problems locally and in the network SIMATIC IPC Image & Partition Creator downtime minimization through preventive data backup SITOP and Masterguard power supply (UPS) Bridging of voltage dips Technical specifications SIMATIC IPC77D SIMATIC IPC477D SIMATIC HMI IPC477C SIMATIC HMI IPC577C SIMATIC HMI IPC677D 7) Design Centralized configuration Display Size 7"/9"/1"/15"/19 Widescreen TFT 1"/15"/19"/" Widescreen TFT 1"/15"/19" TFT 1"/15"/19" TFT " Widescreen TFT Resolution 800 x 480 / 800 x 480 / 180 x 800 / 180 x 800 / 1366 x 768 Operator controls 180 x 800 / 180 x 800 / 1366 x 768/ 190 x x 600 / 104 x 768 / 180 x x 600 / 1 04 x 768 / 1 80 x 1 04 Membrane keyboard - 8) 1) 1) - Touch screen General features Power supply /- /- /- / / 4 V DC / 110/40 V AC Processor Intel Atom E640, 1.0 GHz; Intel Atom E660, 1.3 GHz Intel Core i7-3517ue, 1.7 GHz, 4 MB SLC Intel Core i3-317ue, 1.6 GHz, 3 MB SLC Intel Celeron 87E 1.4 GHz, 1.5 MB SLC Intel Celeron M 1. GHz Intel Core Solo 1. GHz Intel Core Duo 1. GHz Intel Celeron M 1. GHz Intel Core Solo 1. GHz Intel Core Duo 1.86 GHz 1 90 x Intel Xeon E3-168L v3 (4C,.3 (3.3) GHz, HT, 8 MB cache, VT-d, AMT) Intel Core i3-4330te, (C,.4 GHz, 4 MB cache, HT, VT-x) Intel Celeron G180TE (C,. GHz, MB cache) /808 Siemens IK PI 015

30 Industrial PC SIMATIC Panel PC General data Techncal specifications (continued) Main memory 1 GB, GB 1 GB, GB, 4 GB, 8 GB Expansion slots Operating system 1 x CF slot for CompactFlash card (externally accessible) Windows Embedded Standard 009 or XP Professional MUI Windows Embedded Standard 7 (3-bit) or Windows 7 Ultimate MUI (3-bit) x CFast slot (externally accessible) Without Windows 7 Ultimate MUI (3-bit or 64-bit) Windows Embedded Standard 7 (3-bit) 1 GB, GB, 4 GB 1 GB, GB, 4 GB GB, expandable up to 16 GB, optional ECC x CF slot for CompactFlash Card (internally and externally accessible) Windows Embedded 009 or XP Professional MUI Windows 7 Ultimate MUI (3-bit) or Windows Embedded Standard 7 (3-bit) 1 x PCI ) 1 x CF slot for CompactFlash card (externally accessible) Without Windows Embedded 009 or XP Professional MUI x PCI or 1 x PCIe 1 x PCI or x PCIe x16/x4 Without Windows 7 Ultimate 3-bit MUI Windows 7 Ultimate 64-bit MUI Interfaces PROFIBUS/MPI - PROFINET (RT/IRT) / - / / / / Ethernet x 10/100/1 000 Mbps x 10/100/1 000 Mbps x 10/100/1 000 Mbps x 10/100/1 000 Mbps x 10/100/1 000 Mbps USB Serial interface Graphics interface - Ambient conditions Vibration load during operation 1 g 1 g 1 g 1 g 3) 1 g 3) Shock loading during operation 5 g 5 g 5 g 5 g 3) 5 g Permissible temperature during operation with maximum configuration Power loss in maximum configuration SIMATIC IPC77D SIMATIC IPC477D SIMATIC HMI IPC477C SIMATIC HMI IPC577C SIMATIC HMI IPC677D 7) +0 C +50 C 7) +0 C +50 C 7) +0 C +50 C 7) +0 C +45 C 7) 6) 8) +5 C +45 C 7" display 7 W 9" display 9 W 1" display 34 W 55 W 40 W 4) 55 W 5) 15" display 4 W 56 W 45 W 4) 57 W 5) 19" display 45 W 65 W 60 W 4) 84 W 5) " display 74 W 170 W 5) Available - Not available 1) 1"/15" displays ) All slots with card retainer 3) Valid with CF or SSD; with HDD: 5 g / 0.5 g; 4) 3 W taken into account for each PCI/PCIe slot 5) 15 W taken into account for each PCI/PCIe slot 6) +0 C to +50 C; max. +50 C in installation space; max. 40 C if at the front 7) +0 C to +45 C for 19" 8) 15" display optionally as Touch/Key version 9) With 1" and 15", vertical installation and use of CFast or SSD More information Additional information is available on the Internet at: Note: Do you need a specific modification or extension to the products described here? Then refer to "Customized Automation". There you will find information about additional and generally available sector-specific products as well as options for customer-specific modification and adaptation. Examples are: Specific front panels for SIMATIC Panel PC, e.g. honing oilresistant or with lateral function/movement keys SIMATIC HMI Net Panel with 46" large-scale display Siemens IK PI 015 /809

31 Industrial PC SIMATIC Panel PC SIMATIC IPC77D Overview SIMATIC IPC77D: The embedded Nanopanel PC maintenance-free and compact with displays starting from 7" Offers great flexibility in the selection of rugged widescreen fronts From 7" to 19" for more freely configurable display area High resolution, large viewing angle, and up to 100% dimmable backlighting for a brilliant display with optimized power consumption Absolutely maintenance-free due to the use of CompactFlash and SSD as mass storage and fanless operation up to 50 C ambient temperature Maximum industrial functionality due to non-volatile retentive memory Ready-to-use embedded bundles with visualization or/and control software The following front installation versions are available: 7" Touch 9" Touch 1" Touch 15" Touch with USB interface on the front 19" Touch with USB interface on the front All fronts as widescreen version Benefits SIMATIC IPC77D Nanopanel PC Rugged, industry-standard widescreen displays (Touch) with 7" / 9" / 1" / 15"/ 19" High resolution, 16 million colors, large viewing angle, can be dimmed from 0 to 100% (this also optimizes the power consumption) Integrated front concept (Panel PC, Comfort Panels) Fanless up to 50 C ambient temperature 15" / 19" with front USB interface available soon High-performance data processing at low power consumption Intel Atom technology of the Power-Optimized family E6xx Wake-on-LAN for remote-controlled switching between standby and active state Support of Sleep States/SpeedStep -> (dynamic power adaptation depending on the required computing performance) Intel VT-x technology for virtualization High degree of industrial functionality and flexibility for implementing the embedded solution Flexible memory concepts: CompactFlash or Solid-State Drive Gbit Ethernet (teaming-capable); PROFINET with RT functionality (via Standard Ethernet) 3 high-speed USB.0 ports 1 RS3 Ready-to-run embedded bundles with WinAC RTX010 (F) and/or WinCC RT Advanced (optional) 51 KB retentive memory (MRAM), of which 18 KB can be written to within the buffer time (optional) High system availability in order to reduce the risk of potential failures and maintenance costs Maintenance-free since there are no rotating parts (fans, HDD) Battery-free operation even if retentive memory option is selected (with time-of-day synchronization over network) Comprehensive self-diagnostics thanks to pre-installed local diagnostics software SIMATIC IPC DiagBase High investment security in order to reduce engineering costs Long-term availability: Service & Support period of 8 10 years after market launch /810 Siemens IK PI 015

32 Industrial PC SIMATIC Panel PC SIMATIC IPC77D Technical specifications General features Processors Chipset NVRAM optional Operating system SIMATIC IPC77D Intel Atom E GHz, GB RAM Intel Atom E GHz, 1 GB RAM Intel Controller Hub EG0T 51 KB, of which 18 KB can be written within the buffer time Windows Embedded Standard 009 preinstalled, in combination with CF card of GB or more, or solid-state drive, or hard drive (optional) Windows XP Professional MUI (in connection with solid-state drive or hard drive; MUI: Multi Language User Interface (optional) Windows Embedded Standard 7 3-bit, preinstalled, in combination with CF card or solid-state drive (optional) Windows 7 Ultimate MUI 3-bit (in combination with solid-state drive; MUI: Multi Language User Interface (optional) Linux 1) (project-specific, on request) Others on request project-specifically Power supply 4 V DC (0.4 V V) Isolated With buffering of temporary power failures: max. 10 ms Line side switch With power failure indication by means of Power Fail signal Drives FlashDrive Optional; replaceable, accessible, diagnosable GB 4 GB 8GB 16 GB Solid-state drive (SSD) Optional 80 GB SATA,.5" 160 GB SATA,.5" CD/DVD/Floppy Via USB (not included in scope of delivery) Ports PROFINET PROFINET RT via Standard Ethernet controller Ethernet x 10/100/1000 Mbps (RJ 45) Two independent Intel Controllers: Intel 8574L / Intel Controller Hub EG0T With teaming function USB V.0, 3 x Serial COM1 (V.4) Keyboard Via USB (not included in scope of delivery) Mouse Via USB (not included in scope of delivery) Monitoring functions Temperature Watchdog Monitoring functions via the network Supply voltage Supply voltage Monitoring functions Temperature Watchdog Mass storage Ambient conditions Vibration load during operation Shock loading during operation Relative humidity Maximum permissible installation angle +/- Ambient temperature during operation Certifications & standards SIMATIC IPC77D Processor temperature Motherboard Messages can be evaluated by the application program Monitoring of program execution Monitoring time can be parameterized in software Can be parameterized for a fault or restart Messages can be evaluated by the application program DiagBase SIMATIC IPC DiagMonitor Remote monitoring capability for: Watchdog Temperature Mass memory monitoring (SMART) System/Ethernet monitoring (Heart Beat) Runtime meter Communication: Ethernet interface (SNMP protocol) OPC for integration in SIMATIC software Configuration of client/server architectures Structure of log files 4 V DC Yes Yes Yes Requirements according to: IEC , tested according to: IEC , Test Fc 10-58: mm, 58-00: 9.8 m/s, 10x /axis Requirements according to: IEC , tested according to: IEC , Test Ea, 50 m/s Tested in accordance with DIN IEC 68-78, DIN IEC : 5% to 80% at 5 C (no condensation) 45 over vertical 0 C +50 C in maximum configuration; no fan (19": 0 C +45 C) Approvals CE, culus (508), marine approval available for 7"/9"/1" (GL, LRS, BV, DNV, ABS, ClassNK) EMC CE, FFC A, 550A, EN , EN ) for specific LINUX versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for LINUX", see (LINUX is a trademark of Linus Torvald) Siemens IK PI 015 /811

33 Industrial PC SIMATIC Panel PC SIMATIC IPC77D Technical specifications (continued) SIMATIC IPC77D Front panel 7" TFT Touch, widescreen 9" TFT Touch, widescreen 1" TFT Touch, widescreen 15" TFT Touch, widescreen 19" TFT Touch, widescreen Display Resolution (W x H in pixels) 800 x x x x x 768 General features Accessories Touch pen, touch protective films Touch pen, touch protective films Touch pen, touch protective films Touch pen, touch protective films Touch pen, touch protective films Type of operation Function keys No No No No No Alphanumeric keyboard No No No No No Touch screen (analog/resistive) Yes Yes Yes Yes Yes USB port on the front No No No Yes Yes Design Centralized configuration Yes Yes Yes Yes Yes Distributed configuration No No No No No Dimensions Mounting dimensions in centralized configuration (W x H x D) in mm 197 x 141 x x 166 x x 1 x x 91 x x 319 x 73 Operator control unit (W x H) in mm 14 x x x x x 337 Weight 1500 g 1950 g 750 g 4000 g 5700 g Max. power loss 7 W 9 W 37 W 4 W 45 W in maximum configuration /81 Siemens IK PI 015

34 Industrial PC SIMATIC Panel PC Ordering data Article No. Article No. SIMATIC IPC77D SIMATIC IPC77D Nanopanel PC 6AV A Interfaces: x Gbit LAN (RJ45), 1 x serial (COM1), 3 x USB Operating unit Touch 7" TFT 1 Touch 9" TFT Touch 1" TFT 3 Touch 15" TFT, 4 front USB interface Touch 19" TFT, 5 front USB interface Processors / memory configuration / NVRAM Atom E640 (1.0 GHz), 1 GB RAM A Atom E640 (1.0 GHz), 1 GB RAM, B NVRAM Atom E660 (1.3 GHz), GB RAM E Atom E660 (1.3 GHz), GB RAM, F NVRAM Drives Without drive, with CF slot 0 GB SIMATIC PC CompactFlash 1 4 GB SIMATIC PC CompactFlash 8 GB SIMATIC PC CompactFlash 3 16 GB SIMATIC PC CompactFlash GB Solid-State Drive SATA 6 80 GB Solid-State Drive SATA 8 Operating system Without operating system A WES 009 preinstalled B (CF from GB/SSD) XP-Prof. MUI preinstalled on SSD C WES 7 3 bit preinstalled D (CF from 4 GB/SSD) Windows 7 MUI 3 bit preinstalled E on SSD Software bundles Without RTX/HMI software A RTX: WinAC RTX 010 B RTX-F: WinAC RTX F 010 C HMI: WinCC RT Advanced 18 PT F HMI: WinCC RT Advanced 51 PT G HMI: WinCC RT Advanced 048 PT H HMI/RTX: RT 18 PT M HMI/RTX: RT 51 PT N HMI/RTX: RT 048 PT P HMI/RTX-F: RT 18 PT R HMI/RTX-F: RT 51 PT S HMI/RTX-F: RT 048 PT T Accessories Touch protective films 7" 1) Touch protective films 9" 1) Touch protective films 1" 1) Touch protective films 15" 1) Touch protective films 19" 1) Bracket clamp, long for 15", 19" and " widescreen, Comfort Panels, IPC, Flat Panel monitors and Thin Client (except SCD " widescreen) Touch pen Captive pen for operation of the touch devices, mounting of the support on the control cabinet or directly on the PRO unit 6AV14-6GJ00-0AX0 6AV14-6JJ00-0AX0 6AV14-6MJ00-0AX0 6AV14-6QJ00-0AX1 6AV14-6UJ00-0AX1 6AV6671-8XK00-0AX4 6AV767-1JB00-0AA0 1) 10 units per packing unit Please be sure to note: The IPC77D with bundled software is always supplied with inserted CF card. The licenses are on the supplied USB flash drive. More information Further information can be found on the Internet at: Siemens IK PI 015 /813

35 Industrial PC SIMATIC Panel PC SIMATIC IPC477D Overview SIMATIC IPC477D: The powerful embedded Panel PC maintenance-free with versatile configuration Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation Maintenance-free (no rotating components such as fan and hard disk) Rugged construction: The PC is resistant to even the harshest mechanical stress and is extremely reliable in operation Compact design Battery-independent retentive memory onboard High degree of investment security Fast integration capability The following front versions are available: Built-in versions - 1" TFT Touch - 15" TFT Touch - 15" TFT Touch/Key - 19" TFT Touch - " TFT Touch - 19" TFT Multi-Touch - " TFT Multi-Touch Benefits Excellent industrial compatibility due to rugged construction, even when subjected to extreme vibration and shock High degree of investment protection thanks to assured availability of spare parts for a period of 5 years following the end of active marketing Excellent continuity of components for machine concepts with a long service life without any new engineering costs Cost and time savings due to service-friendly device design: - Front and rear USB.0 ports for quick and easy connection of additional hardware components High degree of industrial functionality thanks to integral PROFIBUS DP/MPI and PROFINET interfaces Maintenance-free due to lack of rotating components (fan and hard disk) High flexibility thanks to expansions (optional) such as PCIe, second RS 3, DVD (not with 1" TFT Touch) Minimization of downtimes thanks to high system availability - Efficient self-diagnostics (DiagBase and SIMATIC IPC DiagMonitor) - High reliability and security of an embedded platform An integral component of Totally Integrated Automation (TIA): - Enhanced productivity, minimization of engineering costs, reduction of lifecycle costs Supply of ready-to-run complete solutions (the software is preinstalled and preconfigured) for visualization and automation in combination with WinCC flexible, WinCC RT Advanced and/or WinAC RTX and WinCC. Technical specifications SIMATIC IPC477D General features Supply voltage 1) 4 V DC (-0 % / +0 %) 1) V AC (-15 % / +0 %); Hz Brief voltage interruption in accordance with NAMUR Power consumption (DC) of devices (without expansions): 1" display 15" display 19" display " display Additional power consumption of devices with expansions: DVD drive PCIe card Min. 0 ms (DC) Min. 0 ms (AC); max. 10 events per hour; min. 1 s recovery time 55 W 56 W 65 W 74 W 1 W 5 W Processor Main memory Buffer memory ) SIMATIC IPC477D Intel Celeron 87E 1.4 GHz; 1.5 MB SLC or Intel Core i3-317ue 1.6 GHz; 3MB SLC or Intel Core i7-3517ue 1.7 GHz; 4MB SLC SO-DIMM module; 104 MB DDR3-SDRAM or SO-DIMM module; 048 MB DDR3-SDRAM or SO-DIMM module; 4096 MB DDR3-SDRAM or SO-DIMM module; 819 MB DDR3-SDRAM 51 KB MRAM /814 Siemens IK PI 015

36 Industrial PC SIMATIC Panel PC SIMATIC IPC477D Technical specifications (continued) Drive and storage media SATA drive Solid-state drive Hard disk drive (HDD) CFast card DVD drive, RW Graphics Display, resolution Touch controller Backlighting (MTBF) Half brightness life time, typical Graphics controller Graphics memory Resolutions, frequency, colors Interfaces COM 1 and COM DVI Display port (DPP) Keyboard Mouse USB SIMATIC IPC477D 1 slot 1x 80 GB;.5" SATA-SSD, standard or 1x 160 GB;.5" SATA-SSD, standard 1x 50 GB,.5"-SATA-HD GB or 4GB or 8GB or 16GB 1 slot for devices with expansion 1" screen diagonal with LED backlighting, resolution 1 80 x 800 pixels, WXGA (Wide XGA) 15" screen diagonal with LED backlighting, resolution 1 80 x 800 pixels, WXGA (Wide XGA) 19" screen diagonal with LED backlighting, resolution x 768 pixels " screen diagonal with LED backlighting, resolution 1 90 x pixels Analog-resistive or capacitive touch LED Min h at 50 C, 50 % brightness Intel HD 000 or Intel HD MB shared memory DVI-I: 640 x x 1 00, 60 Hz DP display port: 1 90 x 1 00, 60 Hz RS 3, max. 115 kbps, 9-pin, sub-d connector Connection of VDUs with DVI connection Connection of VDUs with DPP connection Connection via USB port Connection via USB port Rear of device: 4 x USB 3.0, max. high-current at the same time Front of device (only with IPC477D with 15", 19" or " display): 1 x USB.0, high-current Ethernet 3) Slot for PCIe expansion cards Degree of protection Degree of protection SIMATIC IPC477D x RJ45 connection, Intel 8579LM and Intel 8574L 10/100/1000 Mbps, electrically isolated, teaming-capable 4) or For PROFINET versions: 1 x Ethernet Only for device with expansions: 1 x PCIe-x4 expansion card can be used, max. permissible power loss: 5 W IP 0 to IEC 6059 (enclosure) IP 65 (front) Quality assurance In accordance with ISO 9001 Electromagnetic compatibility Emitted interference S EN ; CISPR Class A; FCC Class A Immunity with regard to conducted interference on the supply lines ± kv to IEC ; burst ± 1 kv to IEC ; surge symmetrical ± kv to IEC ; surge asymmetrical Noise immunity on signal lines ± kv to IEC ; burst, length > 3 m ± 1 kv to IEC ; burst, length < 3 m ± kv to IEC ; symmetrical surge, length > 30 m Immunity to static discharge ± 6 kv, contact discharge at the front to IEC ± 4 kv contact discharge at the rear to IEC ± 8 kv air discharge to IEC Immunity to high radio frequency interference Immunity to magnetic fields Weight IPC477D, touch device, 1" display IPC477D, touch device, 15" display IPC477D, touch/key device (without expansions), 15" display IPC477D, touch device, 19" display IPC477D, touch device, " display 10 V/m, MHz 80 % AM to IEC V/m,.7 GHz 3 V/m,.7 GHz 10 V, 10 khz 80 MHz to IEC A/m, 50/60 Hz to IEC approx g approx g approx g approx g approx g PROFIBUS/MPI Transmission rate Operating modes PROFINET 9-pole, rows, electrically isolated, Sub-D socket, compatible with CP Kbps 1 Mbps DP master: DP-V0, DP-V1 with SOFTNET-DP DP slave: DP-V0, DP-V1 with SOFTNET-DP slave 3 x RJ45 interface, CP 1616 compatible onboard interface based on ERTEC /100 Mbps, electrically isolated 1) The generation of the supply voltage by the line-side power supply must be realized as safety extra-low voltage with safe electrical isolation, isolated according to IEC , or as SELV according to IEC/UL/EN/DIN-EN ) For devices with retentivity 3) For unambiguous labeling, the Ethernet ports are numbered on the enclosure. The numbering by the operating system can differ. 4) Teaming can be set and initiated in the configuration interface. In teaming operation, jumbo frames, e.g. for the camera application, are not supported Siemens IK PI 015 /815

37 Industrial PC SIMATIC Panel PC SIMATIC IPC477D Ordering data Article No. Article No. SIMATIC IPC477D 1) 6AV Processor and fieldbus: Celeron U87E (1C/1T, 1.4 GHz, MB cache); x Gigabit Ethernet (IE/PN) Celeron U87E (1C/1T, 1.4 GHz, MB cache); x Gigabit Ethernet (IE/PN); PROFIBUS DP1 Core i3-317ue (C/4T, 1.6 GHz, 3 3 MB cache); x Gigabit Ethernet (IE/PN) Core i3-317ue (C/4T, 1.6 GHz, 4 3 MB cache); x Gigabit Ethernet (IE/PN); PROFIBUS DP1 Core i3-317ue (C/4T, 1.6 GHz, 5 3 MB cache); 1 x Gigabit Ethernet (IE/PN); 1 x PROFINET (IRT, 3 ports) Core i7-3517ue (C/4T, 1.7 (.8) 6 GHz, 3 MB cache); x Gigabit Ethernet (IE/PN) Core i7-3517ue (C/4T, 1.7 (.8) 7 GHz, 3 MB cache); x Gigabit Ethernet (IE/PN); PROFIBUS DP1 Core i7-3517ue (C/4T, 1.7 (.8) 8 GHz, 3 MB cache); 1 x Gigabit Ethernet (IE/PN); 1 x PROFINET (IRT, 3 ports) Operator control unit: 1" Touch (1 80 x 800) A (caution, restrictions regarding options: HDD, PCI, AC, DVD) 15" Touch (1 80 x 800) with front B USB 15" Touch/Key (1 80 x 800) with C front USB 19" Touch (1 366 x 768) with front D USB " Touch (1 90 x 1 080) with front E USB 19" Multi-Touch (1 366 x 768) without front USB K " Multi-Touch (1 90 x 1 080) L without front USB Main memory/nvram 1 GB A GB B 4 GB C 8 GB D 1 GB and NVRAM J GB and NVRAM K 4 GB and NVRAM L 8 GB and NVRAM M Expansions/interface: 1 x RS 3, without PCIe 0 1 x RS 3 and 1 x PCIe 1 Second RS 3, without PCIe 3 Second RS 3 and 1 x PCIe 4 Operating system: Without operating system 0 Windows Embedded Standard 7 3 Professional, 3-bit, MUI Windows Embedded Standard 7 4 SP1, English, 3-bit Windows Embedded Standard 7 5 SP1, English, 64-bit Windows 7 Ultimate SP1, 3-bit, 6 MUI (Eng, Ger, Fr, It, Sp) Windows 7 Ultimate SP1, 64-bit, 7 MUI (Eng, Ger, Fr, It, Sp) SIMATIC IPC477D 1) 6AV Externally accessible mass storage (without operating system): Without external mass storage 0 CFAST GB, without software 1 CFAST 4 GB CFAST 8 GB 3 CFAST 16 GB 4 DVD 6 Internal mass storage: Without internal mass storage A CFAST GB B CFAST 4 GB C CFAST 8 GB D CFAST 16 GB E SSD 80 GB Standard H HDD 50 GB K DVD L SSD 80 GB standard with DVD N SSD 160 GB standard without DVD P HDD min. 50 GB with DVD Q SIMATIC software preinstalled (bundles): Without SIMATIC software A WinAC RTX 010 ) B WinCC RT Advanced 18 PT C WinCC RT Advanced 51 PT D WinCC RT Advanced 048 PT E WinCC RT Advanced PT F WinCC RT Advanced 18 PT, J WinAC RTX ) WinCC RT Advanced 51 PT, K WinAC RTX ) WinCC RT Advanced 048 PT, L WinAC RTX ) WinCC RT Advanced PT, M WinAC RTX ) WinAC RTX 010 F ) N WinCC RT Advanced 18 PT, P WinAC RTX F ) WinCC RT Advanced 51 PT, Q WinAC RTX F ) WinCC RT Advanced 048 PT, R WinAC RTX F ) WinCC RT Advanced PT, S WinAC RTX F ) WinCC RT Professional Y Client/single-user station 18 PT Power supply: 4 V DC industrial power supply 0 110/30 V AC industrial power 1 supply with Namur; no power cable 110/30 V AC industrial power supply with Namur; European power cable 110/30 V AC industrial power 3 supply with Namur; US power cable 110/30 V AC industrial power 4 supply with Namur; Chinese power cable 110/30 V AC industrial power 5 supply with Namur; Italian power cable 110/30 V AC industrial power 6 supply with Namur; Swiss power cable 110/30 V AC industrial power 7 supply with Namur; UK power cable 4 V DC industrial power supply 8 and TPM (not for China and Russia) 1) Built to order versions with a delivery time of max. 15 working days and with identified repair. ) Only with main memory and NVRAM. /816 Siemens IK PI 015

38 Industrial PC SIMATIC Panel PC SIMATIC HMI IPC577C Overview Rugged, expandable industry PC for demanding tasks in the area of PC-based automation with various control units (front panels): Rugged and compact design for industrial use Full PC openness - Windows Embedded Standard or Windows XP Professional, or without operating system - CF card, HDD, SSD - DVD drive Expandable using a PCI slot Optionally with PROFIBUS or PROFINET (RT/IRT) onboard Installation-compatible with Panel PC 577B - Touch screen control units with 1", 15" and 19" TFT display - 1" and 15" TFT Key High degree of investment protection Benefits High performance due to powerful processor Low-cost entry-level industry PC with full PC openness. Ideal for applications in industrial environments due to - Excellent operational reliability even when subjected to extreme vibration and shock - High degree of chemical resistance to oils and grease - Smooth front, therefore no dirt can accumulate - Brilliant displays for good clearness of display, even when lighting conditions and viewing angles change. High degree of investment protection due to - A long marketing period (4-6 years) and high continuity of components for long-term machine concepts - Assured availability of spare parts (for a period of 5 years following the end of active marketing) - Simple migration from the predecessor product with minimum engineering overhead - Same installation dimensions as predecessor - Early detection of faults and minimized downtimes due to self-diagnostics (DiagBase) High level of flexibility due to - Expandable by the customer thanks to diverse interfaces (PCI, CompactFlash, Gbit Ethernet, and others) - USB interfaces on the front and rear for quick and easy connection of additional hardware components - User-friendly and easy integration in the fieldbus level, thanks to integrated PROFIBUS DP/MPI and Gigabit Ethernet interfaces (onboard) Siemens IK PI 015 /817

39 Industrial PC SIMATIC Panel PC SIMATIC HMI IPC577C Technical specifications 6AV AV AV AV AV SIMATIC HMI SIMATIC HMI SIMATIC HMI SIMATIC HMI SIMATIC HMI IPC577C IPC577C IPC577C IPC577C IPC577C Operator control and monitoring Accessory components Touch protective foil Slide-in keyboard labels Touch protective foil Slide-in keyboard labels Touch protective foil Display Screen diagonal 1 in 1 in 15 in 15 in 19 in Resolution (pixels) Resolution (WxH in pixel) 800 x x x x x 104 General features Front panel 1" TFT touch display 1" TFT Key 15" TFT touch display 15" TFT Key 19" TFT Touch Backlighting MTBF backlighting (at 5 C) about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours Control elements Function keys No 36 No 36 No Mouse, at front No Yes No Yes No Keyboard fonts alphanumeric keyboard No Yes No Yes No Touch operation Design as touch screen Yes No Yes No Yes Installation type/mounting central design Yes Yes Yes Yes Yes distributed design No No No No No Power loss Power loss in full configuration Dimensions Mounting cutout/device depth (W x H x D) additional mounting depth (optical drive) 4V DC: Max. 80 W (incl. USB interfaces) 368 mm x 90 mm x 115 mm 4V DC: Max. 80 W (incl. USB interfaces) 450 mm x 90 mm x 115 mm 4V DC: Max. 80 W (incl. USB interfaces) 450 mm x 90 mm x 10 mm 4V DC: Max. 80 W (incl. USB interfaces) 450 mm x 31 mm x 115 mm 3 mm 3 mm 3 mm 3 mm 3 mm Weights Panel PC in central design, approx. 8.1 kg 8.6 kg 9kg 9.3 kg 11.6 kg 4V DC: Max. 80 W (incl. USB interfaces) 450 mm x 380 mm x 15 mm /818 Siemens IK PI 015

40 Industrial PC SIMATIC Panel PC Ordering data Article No. Article No. SIMATIC HMI IPC577C SIMATIC HMI IPC577C 6AV Front Panels 1" TFT Touch 0 1" TFT Key 1 15" TFT Touch 15" TFT Key 3 19" TFT Touch 5 Mainboards (processor with fieldbus interfaces) Celeron M 1. GHz, 1 MB cache, 800 MHz FSB - with PROFINET A A (Industrial Ethernet); x LAN 1 Gbps Core Solo 1. GHz, 3 MB cache, 800 MHz FSB - with PROFINET A D (Industrial Ethernet), x LAN 1 Gbps - with PROFIBUS DP1/MPI A E (CP5611-compatible), x LAN 1 Gbps - with PROFINET (RT/IRT) 3 ports, A F 1x LAN 1 Gbps Core Duo 1.86 GHz, 6 MB cache, MHz FSB - with PROFINET A K (Industrial Ethernet), x LAN 1 Gbps - with PROFIBUS DP1/MPI A L (CP5611-compatible), x LAN 1 Gbps - with PROFINET (RT/IRT) 3 ports, A M 1x LAN 1 Gbps RAM 1 GB RAM, DDR3 1 GB RAM, DDR3 4 GB RAM, DDR3 3 Second mass storage and/or drive (formatted without operating system) No second mass storage/drive 0 DVD-RW drive 1 HDD + DVD-RW drive SSD 50 GB High Endurance+ 3 DVD-RW drive SSD 80 GB Standard+ DVD-RW 4 drive SSD 50 GB High Endurance 6 SSD 80 GB Standard 7 HDD min. 50 GB 8 First mass storage (formatted, optionally with operating system) without 0 HDD min. 50 GB (not if nd mass 1 storage HDD or SSD) GB CompactFlash 4 GB CompactFlash 3 8 GB CompactFlash 4 16 GB CompactFlash 5 SSD 50 GB High Endurance (not 6 if nd mass storage HDD or SSD) SSD 80 GB Standard (not if nd 7 mass storage HDD or SSD) SIMATIC HMI IPC577C 6AV Operating system (pre-installed on first mass storage) Without operating system A Windows Embedded Standard B Windows XP D Professional Multi-Language 1) Windows Embedded Standard 7 E Windows 7 G Ultimate Multi-Language 1) Expansion (software) Without expansion A IPC DiagMonitor V4.3 enclosed B IPC Image & Partition Creator C IPC DiagMonitor V4.3 and Image D & Partition Creator V3. enclosed Power supply 100/40 V AC industrial power 1 supply with Namur 100/40 V AC industrial power supply with Namur; power cable for Europe 100/40 V AC industrial power 3 supply with Namur; power cable for the USA 100/40 V AC industrial power 4 supply with Namur; CN power cable 100/40 V AC industrial power 5 supply with Namur; IT power cable 100/40 V AC industrial power 6 supply with Namur; CH cable 100/40 V AC industrial power 7 supply with Namur; UK cable 4 V DC industrial power supply 8 1) Multi-Language means: D/E/F/I/SP/CHIN traditional/chin simplified/ Korean/Japanese Note: Software Packages with SIMATIC WinCC flexible, SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC with a price advantage. More information under "Embedded Bundles / Packages for industrial PCs". Accessories Protective film for SIMATIC HMI IPC577C For protecting the touch screen against dirt/scratches, set of 10 for 1" Touch for 15" Touch for 19" Touch Labeling strips for Key devices For labeling soft keys and function keys, blank, supplied in sets of 10 Touch pen Captive pen for operation of the touch devices, mounting of the support on the control cabinet Expansion components 6AV7671-BA00-0AA0 6AV7671-4BA00-0AA0 6AV767-1CE00-0AA0 6AV767-0DA00-0AA0 6AV767-1JB00-0AA0 See catalog ST 80 / ST PC More information Additional information is available in the Internet under: Siemens IK PI 015 /819

41 Industrial PC SIMATIC Panel PC SIMATIC IPC677D Overview IPC 677D front view SIMATIC IPC677D: The high-end Panel PC with maximum performance, functional scope and expansion capability Rugged construction: The PC is resistant to even the harshest mechanical stress and is reliable in operation. Compact design High degree of investment protection Fast integration capability Widescreen front panel versions: - " Touch (other front panels available soon: 15", 19" Touch and 15", 19" and " Multi-Touch) Benefits Excellent industrial compatibility due to rugged construction, even when subjected to extreme vibration and shock High degree of investment protection thanks to assured availability of spare parts (for a period of 5 years following the end of active marketing) Excellent continuity of components for machine concepts with a long service life without any new engineering costs Savings in time and costs due to service-friendly equipment construction: - Operator control unit and computer unit are easy to separate for speedy component replacement - Front and rear USB 3.0 interfaces for quick and easy connection of additional hardware components High degree of industrial functionality thanks to integrated PROFIBUS DP/MPI or PROFINET (CP 1616-compatible) and Gigabit Ethernet interfaces x 50 GB SATA hard disk system (configured as singledisk system or RAID1) 40 GB SSD as rugged and high-speed hard disk substitute Reduction in downtimes through high system availability Minimized energy consumption thanks to support for Wake-On-LAN, shutdown or dimming of the display during operation, and use of Notebook components Efficient self-diagnostics (SIMATIC IPC DiagMonitor or DiagBase): Solutions for preventive data backup Integral component of Totally Integrated Automation (TIA): increases productivity, minimizes the engineering outlay, reduces the lifecycle costs /80 Siemens IK PI 015

42 Industrial PC SIMATIC Panel PC SIMATIC IPC677D Technical specifications General features Processor Main memory Free slots for expansions Operating system Power supply MTBF backlighting Drives Optical drives Hard disk/mass storage Interfaces Graphics interface Connection for keyboard/mouse Serial interface PROFIBUS DP/MPI 6AV760- Xeon E3-168Lv3 (4C/8T,.3 (3.3) GHz, 8 MB cache, VT-d, AMT) Core i3-4330te (C/4T,.4 GHz, 4 MB cache, VT-x) Celeron G180TE (C/T,. GHz, MB cache) GB, optionally 4, 8 or 16 GB, or 8 or 16 GB with ECC x PCI (slot with card retainer) or 1 x PCI and 1 x PCIe x16 or 1 x PCIe x16 and 1 x PCIe x4 Windows 7 Ultimate 3-bit or 64-bit 4 V DC or 110/40 V AC (autorange), 50/60 Hz Typ h (at 4 h continuous operation, temperature-dependent) Optional DVD±RW±R combo drive, at the rear, operable from the side 3.5" SATA hard disk 50 GB; optional 3.5" SATA hard disk 500 GB, Dual hard disk module x 50 GB SATA as single disk configuration or RAID1 preconfigured, 40 GB SSD (solid-state drive) DVI-I and DisplayPort USB / USB COM1: 1 x V.4 (RS3) Onboard (optional), isolated, max. 1 Mbit/s, compatible with CPC56, not upgradeable PROFINET (IRT) Onboard (optional), 3 x RJ 45, CPC1616-compatible, not upgradeable PROFINET (IE), Ethernet Onboard, x 10/100/1000 Mbit USB 1 x on front, 4 x on rear, USB 3.0 (500 ma) Audio Possible via USB (external) Multimedia No Monitoring functions Temperature Watchdog Ambient conditions Degree of protection Vibration load during operation 1) Valid with SSD; with HDD: 5 g/0.5 g Yes Yes Front: IP65, Rear: IP0 Tested according to DIN IEC : Hz: mm, 58 to 500 Hz: 10 m/s² (1 g) 1) Shock loading during operation Tested to DIN IEC , IEC : 50 m/s² (5 g), 30 ms, 100 shocks EMC CE, FCC A, EN , EN , CISPR Ambient temperature during operation Relative humidity Maximum permissible installation angle +/- Certifications & standards Approvals Expansion components 6AV760-5 C +45 C in maximum configuration Tested according to DIN IEC , DIN IEC : 5% to 80% at 5 C (no condensation) 0 over vertical CE, culus(508), FCC, KC, C-Tick Uninterruptible power supply (UPS), SIMATIC NET communication modules, SIMATIC IPC DiagMonitor, SIMATIC IPC Image & Partition Creator, SIMATIC IPC USB FlashDrive Siemens IK PI 015 /81

43 Industrial PC SIMATIC Panel PC SIMATIC IPC677D Ordering data Article No. Article No. SIMATIC IPC677D (Production and delivery as per order) SIMATIC IPC677D 6AV HD graphics onboard; x Gigabit Ethernet (IE/PN) RJ45; 4 x USB V3.0; 1x serial (COM1); RAID controller onboard; watchdog, temp./fan monitoring Operating unit " Touch (1 90 x 1 080) Processor Celeron G180TE (C/T,. GHz, MB cache); Celeron G180TE (C/T,. GHz, MB cache); PROFIBUS/MPI (CP 56-compatible); MB battery-backed SRAM; Celeron G180TE (C/T,. GHz, MB cache); PROFINET (IRT, 3 ports, CP 1616-compatible); MB battery-backed SRAM; Core i3-4330te(c/4t,.4 GHz, 4 MB cache, VT-x); Core i3-4330te (C/4T,.4 GHz, 4 MB cache, VT-x); PROFIBUS/MPI (CP 56-compatible); MB battery-backed SRAM; Core i3-4330te (C/4T,.4 GHz, 4 MB cache, VT-x); PROFINET (IRT, 3 ports, CP 1616-compatible); MB battery-backed SRAM; Xeon E3-168Lv3 (4C/8T,.3 (3.3) GHz, 8 MB cache, VT-d, AMT); Xeon E3-168Lv3 (4C/8T,.3 (3.3) GHz, 8 MB cache, VT-d, AMT); PROFIBUS/MPI (CP 56-compatible); MB battery-backed SRAM; Xeon E3-168Lv3 (4C/8T,.3 (3.3) GHz, 8 MB cache, VT-d, AMT); PROFINET (IRT, 3 ports, CP 1616-compatible); MB battery-backed SRAM. Drives 50 GB HDD SATA; 50 GB HDD SATA; DVD+/-RW; 500 GB HDD SATA; 500 GB HDD SATA; DVD+/-RW; RAID1 x 50 GB SATA (.5"); RAID1 x 50 GB SATA (.5"); DVD+/-RW; Solid-state drive 40 GB; Solid-state drive 40 GB; 50 GB HDD SATA (.5") Solid-state drive 40 GB; 50 GB HDD SATA (.5"); DVD+/-RW; Solid-state drive 160 GB. A B C D E F G H J A B D E G H M N P Y SIMATIC IPC677D 6AV Memory configuration GB DDR DIMM; 1 4 GB DDR DIMM; 8 GB DDR DIMM; 3 16 GB DDR DIMM; 4 8 GB DDR DIMM; ECC; 5 16 GB DDR DIMM; ECC. 6 Expansions (HW) x PCI; 0 1 x PCIe (x16); 1 x PCI; 1 1 x PCIe (x16); 1 x PCIe (x4).. Expansions (HW) Without expansion (HW) 0 x USB in addition 1 (1 slot occupied) COM; LPT (1 slot occupied) x USB in addition 3 (1 slot occupied); COM; LPT ( slots occupied). Operating system Windows 7 Ultimate, 3-bit SP1, A MUI (Eng, Ger, Fr, It, Sp); Windows 7 Ultimate, 64-bit SP1, B MUI (Eng, Ger, Fr, It, Sp); without. X expansions (SW) SIMATIC IPC DiagMonitor V4.x A enclosed; SIMATIC IPC Image & Partition B Creator V3.x enclosed; SIMATIC IPC DiagMonitor V4.x, C Image & Partition Creator V3.x enclosed; without; X TPM module; Y (not for China and Russia). Country-specific version/ power supply 110/30 V AC industrial power 0 supply with NAMUR; European power cable; 110/30 V AC industrial power 1 supply with NAMUR; UK power cable; 110/30 V AC industrial power supply with NAMUR; power cable for Switzerland; 110/30 V AC industrial power 3 supply NAMUR; US power cable; 110/30 V AC industrial power 4 supply NAMUR; power cable for Italy; 110/30 V AC industrial power 5 supply with NAMUR; power cable for China; 4 V DC industrial power supply. 6 /8 Siemens IK PI 015

44 Industrial PC SIMATIC Panel PC SIMATIC IPC677D Ordering data Article No. More information Accessories Memory expansion GB DDR SDRAM, DIMM 4 GB DDR SDRAM, DIMM 8 GB DDR SDRAM, DIMM 8 GB DDR SDRAM, DIMM, ECC Non-heating apparatus cable for SIMATIC Box and Panel PC SIMATIC PC power cable, 30 V AC, angled, 3 m, for: Germany United Kingdom Switzerland USA Italy China 6ES7648-AJ50-0MA0 6ES7648-AJ60-0MA0 6ES7648-AJ70-0MA0 6ES7648-AJ70-1MA0 6ES7900-1AA00-0XA0 6ES7900-1BA00-0XA0 6ES7900-1CA00-0XA0 6ES7900-1DA00-0XA0 6ES7900-1EA00-0XA0 6ES7900-1FA00-0XA0 Additional information is available on the Internet at: Note Do you need a specific modification or option for the products described here? Under "Customized products", you will find information about additional sector-specific products that can be ordered as well as about options for customer-specific modification and adaptation. Touch pen Captive pen for operation of the touch devices, mounting of the support on the control cabinet 6AV767-1JB00-0AA0 Expansion components See catalog ST 80 / ST PC Siemens IK PI 015 /83

45 Industry monitors and Thin Clients SIMATIC Industrial Flat Panel MT Overview SIMATIC IFP1900 MT Flat Panel Monitor industrial monitors with innovative multi-touch operation and brilliant display for the next generation of operating concepts. Installation: - Equally suited to installation in machines, control cabinets, consoles, and gantries or in 19" racks Operator input options: - Innovative projected capacitive touch technology (PCT) - Optimized touch technology for industrial requirements with multi-touch operation - High protection against incorrect operation thanks to detection and filtering out of ball of hand, drops of water, and cleaning operations Benefits Detection of 5 fingers simultaneously with high touch resolution for exact operation Can also be used as a single touch device Intelligent detection of operator errors (e.g. detection of ball of hand, detection of drops, contamination, etc.) Touch operation without pressure Pleasing tactile feedback during operation Anti-glare surface for good readability from large viewing angle Operation possible with appropriate work gloves High-quality and modern front design Widescreen display for clear GUI design Sharp and high-contrast displays, LED backlighting for uniform brightness improves readability High shock and vibration resistance as well as high electromagnetic compatibility ensure failure safety and a long service life All-round metal frame protects glass edge from mechanical damage Software support - Individual programming using the tablet functions of Windows 7/8 - SIMATIC WinCC V7. with Windows 7 - SIMATIC WinCC Version 1.5 or higher Long service life Technical specifications 6AV TB01-0AA0 IFP1900 MT General information Short designation Flat Panel 19" Multitouch ext. Display Screen diagonal 18.5 in Screen diagonal (cm) 47 cm Display width mm Display height 30.4 mm visible area (HxV) in mm 30 x 410 Viewing angle 170 x 170 Type TFT widescreen display, LED backlighting On Screen Display (OSD) No, can be set with the software configuration Number of colors (bit levels) 4 bit Number of colors Resolution (pixels) Horizontal image resolution Vertical image resolution 768 Resolution (WxH in pixel) 1366 x 768 General features Detachable from computer unit 30 m Brightness/contrast 300cd/m² / 1000:1 Brightness, max. 300 cd/m² Backlighting Backlighting (type) LED MTBF backlighting h; At 5 C (up to 50%, at 5 C) Dimmable backlight Yes; % Control elements Function keys No Mouse/cursor control external mouse USB Touch operation Touch keyboard Yes Installation type/mounting Built-in unit Yes Permissible angle to the 35 vertical backward (console) Permissible angle to the 35 vertical forward (ceiling mounting) Supply voltage Type of supply voltage AC, DC Rated value (DC) 4 V permissible range, lower limit (DC) 19. V permissible range, upper limit (DC) 8.8 V Rated value (AC) 0 V; V, 50/60Hz permissible range, lower limit (AC) 85 V permissible range, upper limit (AC) 65 V Power losses Power loss AC Typical 40 W Maximum 60 W Power loss DC Typical 40 W Maximum 65 W /84 Siemens IK PI 015

46 Industry monitors and Thin Clients SIMATIC Industrial Flat Panel MT Technical specifications (continued) Ordering data Article No. 6AV TB01-0AA0 IFP1900 MT Interfaces USB on the rear Video interfaces DVI-D Yes Display port Yes; Display port V1.1 Touch interfaces USB Yes SIMATIC IFP1900 MT Flat Panel, 19" display (16:9), operation using multitouch gestures, extended version up to 30 m, 1366 x 768 pixels, for 4 V DC and V AC, display port/dvi interface, incl. 1.8 m DVI/USB cable 6AV7466-7TB01-0AA0 Degree and class of protection IP65 at front Yes Enclosure Type 4 at the front Yes NEMA4 at the front No NEMA4X at the front No IP0 rear Yes Standards, approvals, certificates UL approval UL 508 Yes EN Yes EN Yes EN Yes EN Yes Ambient conditions Min. ambient temperature 0 C Max. ambient temperature 45 C Relative humidity Relative humidity during operation 95 % Vibrations Vibration load in operation Vibration load during transport/storage g (m/s²) g (m/s²) Shock testing Shock loading in operation Shock load during transport/storage g (m/s²) g (m/s²) Connection method Connector for cooling devices Yes Mechanics/material Type of housing (front) Aluminum aluminum Yes Dimensions Width of the housing front 483 mm Height of housing front 337 mm Mounting cutout/device depth (W x H x D) Mounting cutout, width Mounting cutout, height 465 mm 319 mm Device depth 6.5 mm Weights Weight without packaging 6.34 kg Weight incl. packaging 9.5 kg Siemens IK PI 015 /85

47 Industry monitors and Thin Clients SIMATIC Industrial Flat Panel Overview The Industrial Flat Panels are rugged industry-standard LCD monitors in a wide screen design. Installation: - Equally suited for installation in the machine, in control cabinets, in consoles, to gantries, or in 19" racks. Type of operator control: - Simple display devices without operator functionality - Optional devices with touch control - Optional devices with multi-touch control - Rear-mounted connection of I/O devices (optional). Technical specifications Benefits Rugged industrial design: - High shock and vibration resistance as well as extremely high electromagnetic compatibility ensure failure safety and a long service life - Enclosure front in IP65/NEMA4 degree of protection, resistant to dust and humidity - Scratch-resistant, anti-glare mineral glass screen, providing high mechanical protection against pressure and scratching - Meets CE standard "Industry" Variety of versions Lower energy requirement Fatigue-proof operation: - Wide reading angle of up to 170 horizontal and vertical - Sharp and high-contrast graphic display - No flickering, uniform brightness - Automatic display adjustment (Auto Adjust) Configuration using On-Screen Display (OSD) Minimal space requirement and low weight Long service life 6AV7863-AA00-6AV7863-AB10-6AV7863-BB10-6AV7863-TA00-0AA0 6AV7863-TB10-0AA0 0AA0 0AA0 0AA0 IFP1500 IFP1500 IFP1500 IFP1500 IFP1500 General information Short designation Flat Panel 15" display Flat Panel 15" display ext. Flat Panel 15" Touch/keys Flat Panel 15" Touch Flat Panel 15" Touch ext. Display Screen diagonal 15.4 in 15.4 in 15.4 in 15.4 in 15.4 in Screen diagonal (cm) 40 cm 40 cm 40 cm 40 cm 40 cm Display width 331. mm 331. mm 331. mm 331. mm 331. mm Display height 07 mm 07 mm 07 mm 07 mm 07 mm Viewing angle 170 x x x x x 170 Type On Screen Display (OSD) configuration TFT widescreen display, LED backlighting No, can be set with the software TFT widescreen display, LED backlighting No, can be set with the software TFT widescreen display, LED backlighting No, can be set with the software TFT widescreen display, LED backlighting No, can be set with the software TFT widescreen display, LED backlighting No, can be set with the software Number of colors (bit levels) 4 bit 4 bit 4 bit 4 bit 4 bit Number of colors Resolution (pixels) Horizontal image resolution Vertical image resolution Resolution (WxH in pixel) 180 x x x x x 800 Pixel size, horizontal 0.59 mm 0.59 mm 0.59 mm 0.59 mm 0.59 mm Pixel size, vertical 0.59 mm 0.59 mm 0.59 mm 0.59 mm 0.59 mm General features Non-reflective and tempered mineral glass screen Yes Yes Yes Detachable from computer unit 5m 30 m 5m 5m 5m Brightness/contrast 400 cd/m² / 1000:1 400 cd/m² / 1000:1 400 cd/m² / 1000:1 400 cd/m² / 1000:1 400 cd/m² / 1000:1 Brightness, max. 400 cd/m² 400 cd/m² 400 cd/m² 400 cd/m² 400 cd/m² Backlighting Backlighting (type) LED LED LED LED LED MTBF backlighting (up to 50%, at 5 C) h; At 5 C h; At 5 C h; At 5 C h; At 5 C h; At 5 C Dimmable backlight Yes; % Yes; % Yes; % Yes; % Yes; % /86 Siemens IK PI 015

48 Industry monitors and Thin Clients SIMATIC Industrial Flat Panel Technical specifications (continued) 6AV7863-AA00-6AV7863-AB10-6AV7863-BB10-6AV7863-TA00-0AA0 6AV7863-TB10-0AA0 0AA0 0AA0 0AA0 IFP1500 IFP1500 IFP1500 IFP1500 IFP1500 Control elements Function keys No No 36 No No Mouse/cursor control external mouse USB USB USB Keyboard fonts Alphanumeric and numeric block Yes Touch operation Touch keyboard Yes Yes Yes Installation type/mounting Built-in unit Yes; Portrait mode possible Yes; Portrait mode possible Yes Yes; Portrait mode possible Yes; Portrait mode possible Permissible angle to the vertical backward (console) Permissible angle to the vertical forward (ceiling mounting) Supply voltage Type of supply voltage DC DC DC DC DC Rated value (DC) 4 V 4 V 4 V 4 V 4 V permissible range, lower limit (DC) 19. V 19. V 19. V 19. V 19. V permissible range, upper limit (DC) 8.8 V 8.8 V 8.8 V 8.8 V 8.8 V Rated value (AC) 100 V; Up to 40V 50/60Hz 100 V; Up to 40V 50/60Hz permissible range, lower limit (AC) 90 V 90 V 90 V permissible range, upper limit (AC) 64 V 64 V 64 V Power losses Power loss AC Typical 40 W 40 W 40 W Maximum 60 W 60 W 60 W Power loss DC Typical 40 W 40 W 40 W 40 W 40 W Maximum 65 W 65 W 65 W 65 W 65 W Interfaces USB on the rear 1 USB at the front 1 Video interfaces DVI-D Yes Yes Yes Yes Yes Display port Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1 Touch interfaces USB No No Yes Yes Yes Degree and class of protection IP65 at front Yes Yes Yes Yes Yes Enclosure Type 4 at the front Yes Yes Yes Yes Yes NEMA4 at the front No No No No No NEMA4X at the front No No No No No IP0 rear Yes Yes Yes Yes Yes Standards, approvals, certificates CE mark Yes Yes Yes Yes Yes KC approval Yes Yes Yes Yes Yes culus Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 RCM (former C-TICK) Yes Yes Yes Yes Yes Use in hazardous areas FM Class I Division Yes No No Yes No Yes; Corresponds to UL 508 Siemens IK PI 015 /87

49 Industry monitors and Thin Clients SIMATIC Industrial Flat Panel Technical specifications (continued) Ambient conditions Min. ambient temperature 0 C 0 C 0 C 0 C 0 C Max. ambient temperature 50 C; Vertical installation (horizontal) 50 C; Vertical installation (horizontal) 50 C; Vertical installation (horizontal) 50 C; Vertical installation (horizontal) Storage/transport temperature Min. -0 C -0 C -0 C -0 C -0 C max. 60 C 60 C 60 C 60 C 60 C Relative humidity Relative humidity during operation 95 %; Non-condensing Vibrations 6AV7863-AA00-6AV7863-AB10-6AV7863-BB10-6AV7863-TA00-0AA0 6AV7863-TB10-0AA0 0AA0 0AA0 0AA0 IFP1500 IFP1500 IFP1500 IFP1500 IFP %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 50 C; Vertical installation (horizontal) 95 %; Non-condensing Vibration load in operation 1g 1g 1g 1g 1g Vibration load during 1g 1g 1g 1g 1g transport/storage Shock testing Shock loading in operation 15 g 15 g 15 g 15 g 15 g Shock load during 15 g 15 g 15 g 15 g 15 g transport/storage Connection method Connector for cooling devices Yes Yes Mechanics/material Type of housing (front) aluminum aluminum aluminum aluminum aluminum Aluminum Yes Yes Yes Yes Yes Dimensions Width of the housing front 415 mm 415 mm 483 mm 415 mm 415 mm Height of housing front 310 mm 310 mm 310 mm 310 mm 310 mm Mounting cutout/device depth (W x H x D) Mounting cutout, width 396 mm; Tolerance: +1 mm 396 mm; Tolerance: +1 mm 450 mm; Tolerance: +1 mm 396 mm; Tolerance: +1 mm 396 mm; Tolerance: +1 mm Mounting cutout, height 91 mm; Tolerance: +1 mm 91 mm; Tolerance: +1 mm 91 mm; Tolerance: +1 mm 91 mm; Tolerance: +1 mm 91 mm; Tolerance: +1 mm Device depth 6.5 mm 6.5 mm 6.5 mm 6.5 mm 6.5 mm Weights Weight without packaging 3.9 kg 3.9 kg 4.3 kg 3.9 kg 3.9 kg Weight incl. packaging 5kg 5kg 5.4 kg 5kg 5kg /88 Siemens IK PI 015

50 Industry monitors and Thin Clients SIMATIC Industrial Flat Panel Technical specifications (continued) 6AV AA00-0AA0 6AV AB10-0AA0 6AV TA00-0AA0 6AV TB10-0AA0 IFP1900 IFP1900 IFP1900 IFP1900 General information Short designation Flat Panel 19" display Flat Panel 19" display ext. Flat Panel 19" Touch Flat Panel 19" Touch ext. Display Screen diagonal 18.5 in 18.5 in 18.5 in 18.5 in Screen diagonal (cm) 47 cm 47 cm 47 cm 47 cm Display width mm mm mm mm Display height 30.4 mm 30.4 mm 30.4 mm 30.4 mm Viewing angle 170 x x x x 160 Type TFT TFT TFT TFT On Screen Display (OSD) configuration No, can be set with the software No, can be set with the software No, can be set with the software No, can be set with the software Number of colors (bit levels) 4 bit 4 bit 4 bit 4 bit Number of colors Resolution (pixels) Horizontal image resolution Vertical image resolution Resolution (WxH in pixel) 1366 x x x x 768 Pixel size, horizontal 0.3 mm 0.3 mm 0.3 mm 0.3 mm Pixel size, vertical 0.3 mm 0.3 mm 0.3 mm 0.3 mm General features Non-reflective and tempered mineral glass screen Yes Yes Detachable from computer unit 5m 30 m 5m 30 m Brightness/contrast 300cd/m² / 1000:1 300cd/m² / 1000:1 300cd/m² / 1000:1 300cd/m² / 1000:1 Brightness, max. 300 cd/m² 300 cd/m² 300 cd/m² 300 cd/m² Backlighting Backlighting (type) LED LED LED LED MTBF backlighting (up to 50%, at 5 C) h; At 5 C h; At 5 C h; At 5 C h; At 5 C Dimmable backlight Yes; % Yes; % Yes; % Yes; % Control elements Function keys No No No No Mouse/cursor control external mouse USB USB Touch operation Touch keyboard Yes Yes Installation type/mounting Built-in unit Yes; Portrait mode possible Yes; Portrait mode possible Yes; Portrait mode possible Yes; Portrait mode possible Permissible angle to the vertical backward (console) Permissible angle to the vertical forward (ceiling mounting) Supply voltage Type of supply voltage DC DC DC DC Rated value (DC) 4 V 4 V 4 V 4 V permissible range, lower limit (DC) 19. V 19. V 19. V 19. V permissible range, upper limit (DC) 8.8 V 8.8 V 8.8 V 8.8 V Rated value (AC) 100 V; Up to 40V 50/60Hz permissible range, lower limit (AC) 90 V 90 V permissible range, upper limit (AC) 64 V 64 V Power losses Power loss AC Typical 40 W 40 W Maximum 60 W 60 W Power loss DC Typical 40 W 40 W 40 W 40 W Maximum 65 W 65 W 65 W 65 W 100 V; Up to 40V 50/60Hz Siemens IK PI 015 /89

51 Industry monitors and Thin Clients SIMATIC Industrial Flat Panel Technical specifications (continued) Interfaces USB on the rear Video interfaces DVI-D Yes Yes Yes Yes Display port Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1 Touch interfaces USB No No Yes Yes Degree and class of protection IP65 at front Yes Yes Yes Yes Enclosure Type 4 at the front Yes Yes Yes Yes NEMA4 at the front No No No No NEMA4X at the front No No No No IP0 rear Yes Yes Yes Yes Standards, approvals, certificates CE mark Yes Yes Yes Yes KC approval Yes Yes Yes Yes culus Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 RCM (former C-TICK) Yes Yes Yes Yes Use in hazardous areas FM Class I Division Yes No Yes Yes Ambient conditions Min. ambient temperature 0 C 0 C 0 C 0 C Max. ambient temperature 6AV AA00-0AA0 6AV AB10-0AA0 6AV TA00-0AA0 6AV TB10-0AA0 IFP1900 IFP1900 IFP1900 IFP C; Vertical installation (horizontal) 45 C; Vertical installation (horizontal) 45 C; Vertical installation (horizontal) 45 C; Vertical installation (horizontal) Storage/transport temperature Min. -0 C -0 C -0 C -0 C max. 60 C 60 C 60 C 60 C Relative humidity Relative humidity during operation 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing Vibrations Vibration load in operation 1g 1g 1g 1g Vibration load during 1g 1g 1g 1g transport/storage Shock testing Shock loading in operation 15 g 15 g 15 g 15 g Shock load during 15 g 15 g 15 g 15 g transport/storage Connection method Connector for cooling devices Yes Yes Mechanics/material Type of housing (front) aluminum aluminum aluminum aluminum Aluminum Yes Yes Yes Yes Dimensions Width of the housing front 483 mm 483 mm 483 mm 483 mm Height of housing front 337 mm 337 mm 337 mm 337 mm Mounting cutout/device depth (W x H x D) Mounting cutout, width 465 mm; Tolerance: +1 mm 465 mm; Tolerance: +1 mm 465 mm; Tolerance: +1 mm 465 mm; Tolerance: +1 mm Mounting cutout, height 319 mm; Tolerance: +1 mm 319 mm; Tolerance: +1 mm 319 mm; Tolerance: +1 mm 319 mm; Tolerance: +1 mm Device depth 6.5 mm 6.5 mm 6.5 mm 6.5 mm Weights Weight without packaging 5.5 kg 5.5 kg 5.5 kg 5.5 kg Weight incl. packaging 6.5 kg 6.5 kg 6.5 kg 6.5 kg /830 Siemens IK PI 015

52 Industry monitors and Thin Clients SIMATIC Industrial Flat Panel Technical specifications (continued) 6AV AA00-0AA0 6AV AB10-0AA0 6AV TA00-0AA0 6AV TB10-0AA0 IFP00 IFP00 IFP00 IFP00 General information Short designation Flat Panel " display Flat Panel " display ext. Flat Panel " Touch Flat Panel " Touch ext. Display Screen diagonal 1.5 in 1.5 in 1.5 in 1.5 in Screen diagonal (cm) 56 cm 56 cm 56 cm 56 cm Display width 476 mm 476 mm 476 mm 476 mm Display height 68 mm 68 mm 68 mm 68 mm Viewing angle 170 x x x x 170 Type TFT TFT TFT TFT On Screen Display (OSD) configuration No, can be set with the software No, can be set with the software No, can be set with the software No, can be set with the software Number of colors (bit levels) 4 bit 4 bit 4 bit 4 bit Number of colors Resolution (pixels) Horizontal image resolution Vertical image resolution Resolution (WxH in pixel) 190 x x x x 1080 Pixel size, horizontal mm mm mm mm Pixel size, vertical mm mm mm mm General features Non-reflective and tempered mineral glass screen Yes Yes Detachable from computer unit 5m 30 m 5m 30 m Brightness/contrast 50 cd/m² / 1000:1 50 cd/m² / 1000:1 50 cd/m² / 1000:1 50 cd/m² / 1000:1 Brightness, max. 50 cd/m² 50 cd/m² 50 cd/m² 50 cd/m² Backlighting Backlighting (type) LED LED LED LED MTBF backlighting (up to 50%, at h; At 5 C h; At 5 C h; At 5 C h; At 5 C C) Dimmable backlight Yes; % Yes; % Yes; % Yes; % Control elements Function keys No No No No Mouse/cursor control external mouse USB USB Touch operation Touch keyboard Yes Yes Installation type/mounting Built-in unit Yes; Portrait mode possible Yes; Portrait mode possible Yes; Portrait mode possible Yes; Portrait mode possible Permissible angle to the vertical backward (console) Permissible angle to the vertical forward (ceiling mounting) Supply voltage Type of supply voltage DC DC DC DC Rated value (DC) 4 V 4 V 4 V 4 V permissible range, lower limit (DC) 19. V 19. V 19. V 19. V permissible range, upper limit (DC) 8.8 V 8.8 V 8.8 V 8.8 V Rated value (AC) 100 V; Up to 40V 50/60Hz 100 V; Up to 40V 50/60Hz permissible range, lower limit (AC) 90 V 90 V permissible range, upper limit (AC) 64 V 64 V Power losses Power loss AC Typical 40 W 40 W Maximum 60 W 60 W Power loss DC Typical 40 W 40 W 40 W 40 W Maximum 65 W 65 W 65 W 65 W Siemens IK PI 015 /831

53 Industry monitors and Thin Clients SIMATIC Industrial Flat Panel Technical specifications (continued) Interfaces USB on the rear Video interfaces DVI-D Yes Yes Yes Yes Display port Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1 Touch interfaces USB No No Yes Yes Degree and class of protection IP65 at front Yes Yes Yes Yes Enclosure Type 4 at the front Yes Yes Yes Yes NEMA4 at the front No No No No NEMA4X at the front No No No No IP0 rear Yes Yes Yes Yes Standards, approvals, certificates CE mark Yes Yes Yes Yes KC approval Yes Yes Yes Yes culus Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 RCM (former C-TICK) Yes Yes Yes Yes Use in hazardous areas FM Class I Division Yes No Yes No Ambient conditions Min. ambient temperature 0 C 0 C 0 C 0 C Max. ambient temperature 6AV AA00-0AA0 6AV AB10-0AA0 6AV TA00-0AA0 6AV TB10-0AA0 IFP00 IFP00 IFP00 IFP00 45 C; Vertical installation (horizontal) 45 C; Vertical installation (horizontal) 45 C; Vertical installation (horizontal) 45 C; Vertical installation (horizontal) Storage/transport temperature Min. -0 C -0 C -0 C -0 C max. 60 C 60 C 60 C 60 C Relative humidity Relative humidity during operation 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing Vibrations Vibration load in operation 1g 1g 1g 1g Vibration load during 1g 1g 1g 1g transport/storage Shock testing Shock loading in operation 15 g 15 g 15 g 15 g Shock load during 15 g 15 g 15 g 15 g transport/storage Connection method Connector for cooling devices Yes Yes Mechanics/material Type of housing (front) aluminum aluminum aluminum aluminum Aluminum Yes Yes Yes Yes Dimensions Width of the housing front 560 mm 560 mm 560 mm 560 mm Height of housing front 380 mm 380 mm 380 mm 380 mm Mounting cutout/device depth (W x H x D) Mounting cutout, width 54 mm; Tolerance: +1 mm 54 mm; Tolerance: +1 mm 54 mm; Tolerance: +1 mm 54 mm; Tolerance: +1 mm Mounting cutout, height 36 mm; Tolerance: +1 mm 36 mm; Tolerance: +1 mm 36 mm; Tolerance: +1 mm 36 mm; Tolerance: +1 mm Device depth 6.5 mm 6.5 mm 6.5 mm 6.5 mm Weights Weight without packaging 6.5 kg 6.5 kg 6.5 kg 6.5 kg Weight incl. packaging 7.6 kg 7.6 kg 7.6 kg 7.6 kg /83 Siemens IK PI 015

54 Industry monitors and Thin Clients Ordering data Article No. Article No. SIMATIC Industrial Flat Panel Industrial Flat Panel Monitor 6AV A A 0 Display size 15 (multi-touch available soon) Operator functionality Display devices without A operator functionality Touch screen (capacitive) M multi-touch Touch screen (analog/resistive) T Touch screen + function keys, 15" B B1 only and extended special functions Special functions Standard, can be located A0 up to 5 m away Extended, for positioning B1 at a distance of up to 30 m, V AC (without supply cable) + special functions Accessories Set of protective films 6AV14-6QJ00-0AX1 for ITC/IFP/TP1500 Set of protective films 6AV14-6UJ00-0AX1 for ITC/IFP/TP1900 Set of protective films 6AV14-6XJ00-0AX1 for ITC/IFP/TP00 Touch pen 6AV767-1JB00-0AA0 Undetachable pen for operation of the touch devices, mounting of the support on the control cabinet or directly on the PRO unit Accessories for standard variants up to 5 m (6AV A0.-0AA0) DisplayPort cable (industrial quality) 3 m 6AV7860-0DH30-0AA0 5 m 6AV7860-0DH50-0AA0 DVI-D cable (industrial quality) 3 m 6AV7860-0BH30-0AA0 5 m 6AV7860-0BH50-0AA0 USB cable (industrial quality) 3 m 6AV7860-0CH30-0AA0 5 m 6AV7860-0CH50-0AA0 Accessories for extended variants up to 30 m (6AV B1.-0AA0) Cable set (USB/Cat5; sender module, DVI) 10 m 6AV7860-1EX1-0AA1 15 m 6AV7860-1EX1-5AA1 0 m 6AV7860-1EX-0AA1 30 m 6AV7860-1EX3-0AA1 Cable set 90 6AV7860-1EX-0BA1 USB/Cat5; sender module, DVI 90 angle, 0 m USB host extender 6AV7671-1EX0-0AA0 incl. 0 cm USB cable (USB to Cat5) Siemens IK PI 015 /833

55 Industry monitors and Thin Clients SIMATIC Flat Panels Overview The Flat Panels are rugged industry-standard LCD monitors. Installation: - They are equally suited to installation in the machine, in control cabinets, consoles and gantries or in 19" racks. - As a device with all-round IP65 protection for mounting on a supporting arm/stand Type of operator control: - Simple display devices without operator functionality - Optional devices with touch control - Rear connection of I/O devices (optional) Benefits Rugged industrial design: - High shock and vibration resistance as well as extremely high electromagnetic compatibility make for a fail-safe and long-lasting design - Enclosure front in degree or protection IP65/NEMA4, resistant against dust and humidity - Enclosure version complete in degree of protection IP65 for mounting on supporting arm - Scratch-resistant, anti-glare mineral glass screen, providing high mechanical protection against pressure and scratching - Meets CE standard "Industry" Variety of versions No X-rays Lower energy requirement Fatigue-proof operation: - Wide reading angle of up to 170 horizontal and vertical - Sharp and high-contrast graphic display - No flickering, uniform brightness - Automatic display adjustment (Auto Adjust) Configuration using on-screen display (OSD) Small space requirement and low weight Long service life /834 Siemens IK PI 015

56 Industry monitors and Thin Clients SIMATIC Flat Panels Technical specifications 6AV7861-1AA00-1AA0 6AV7861-1AB00-1AA0 6AV7861-1AB10-1AA0 6AV7861-1KB10-1AA0 6AV7861-1TA00-1AA0 6AV7861-1TB00-1AA0 6AV7861-1TB10-1AA0 Display Screen diagonal 1 in 1 in 1 in 1 in 1 in 1 in 1 in visible area (HxV) in mm 46 x 184,5 46 x 184,5 46 x 184,5 46 x 184,5 46 x 184,5 46 x 184,5 46 x 184,5 Viewing angle 140 x x x x x x x 10 On Screen Display (OSD) Yes Yes Yes Yes Yes Yes Yes configuration Number of colors (bit levels) 6k 6k 6k 6k 6k 6k 6k Number of colors 6 000; 6k 6 000; 6k 6 000; 6k 6 000; 6k 6 000; 6k 6 000; 6k 6 000; 6k Resolution (pixels) Horizontal image resolution Vertical image resolution Resolution (WxH in pixel) 800 x x x x x x x 600 General features Brightness/contrast > 350 cd/m² / 450:1 > 350 cd/m² / 450:1 > 350 cd/m² / 450:1 > 350 cd/m² / 450:1 > 350 cd/m² / 450:1 > 350 cd/m² / 450:1 > 350 cd/m² / 450:1 Control elements Function keys No No No No No No No Operating mode integrated mouse cursor control No No No No No No No Installation type/mounting Rack mounting possible No No No No No No No Desktop device No No No No No No No VESA mounting No No No No No No No Supply voltage Type of supply voltage AC, DC AC, DC AC, DC AC, DC AC, DC AC, DC AC, DC permissible range, lower limit (DC) 19. V 19. V 19. V 19. V 19. V 19. V 19. V permissible range, upper limit (DC) 8.8 V 8.8 V 8.8 V 8.8 V 8.8 V 8.8 V 8.8 V permissible range, lower limit (AC) 90 V 90 V 90 V 90 V 90 V 90 V 90 V permissible range, upper limit (AC) 64 V 64 V 64 V 64 V 64 V 64 V 64 V Interfaces Video interfaces analog video signal (VGA) Yes Yes Yes Yes Yes Yes Yes Degree and class of protection IP54 at front IP65 at front Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners IP0 rear Yes Yes Yes Yes Yes Yes Yes Standards, approvals, certificates UL Yes Yes Yes Yes Yes Yes Yes EAC (former Gost-R) No No No No No No No Marine approval Germanischer Lloyd (GL) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional American Bureau of Shipping (ABS) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Bureau Veritas (BV) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Det Norske Veritas (DNV) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Lloyds Register of Shipping (LRS) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Polski Rejestr Statkow (PRS) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Ambient conditions Max. ambient temperature 50 C 50 C 50 C 50 C 50 C 50 C 50 C Dimensions Width of the housing front 400 mm 400 mm 400 mm 483 mm 400 mm 400 mm 400 mm Height of housing front 310 mm 310 mm 310 mm 310 mm 310 mm 310 mm 310 mm Mounting cutout/device depth 368 x 90 x x 90 x x 90 x x 90 x x 90 x x 90 x x 90 x 51 (W x H x D) Device depth 51 mm 51 mm 51 mm 49 mm 50 mm 51 mm 51 mm Siemens IK PI 015 /835

57 Industry monitors and Thin Clients SIMATIC Flat Panels Technical specifications (continued) 6AV7861- AA00-1AA0 6AV7861- AB00-1AA0 6AV7861- AB10-1AA0 6AV7861- KB10-1AA0 6AV7861- TA00-1AA0 6AV7861- TB00-1AA0 6AV7861- TB10-1AA0 Display Screen diagonal 15 in 15 in 15 in 15 in 15 in 15 in 15 in visible area (HxV) in mm 304 x x x x x x x 8 Viewing angle 100 x 90 (min) 100 x 90 (min) 100 x 90 (min) 100 x 90 (min) 100 x 90 (min) 100 x 90 (min) 100 x 90 (min) On Screen Display (OSD) Yes Yes Yes Yes Yes Yes Yes configuration Number of colors (bit levels) 16. million 16. million 16. million 16. million 16. million 16. million 16. million Number of colors ; 16. million ; 16. million ; 16. million ; 16. million ; 16. million ; 16. million ; 16. million Resolution (pixels) Horizontal image resolution Vertical image resolution Resolution (WxH in pixel) 104 x x x x x x x 768 General features Brightness/contrast > 60 cd/m² / 350:1 > 60 cd/m² / 350:1 > 60 cd/m² / 350:1 > 60 cd/m² / 350:1 > 60 cd/m² / 350:1 > 60 cd/m² / 350:1 > 60 cd/m² / 350:1 Control elements Function keys No No No No No No No Operating mode integrated mouse cursor control No No No No No No No Installation type/mounting Rack mounting possible Yes Yes Yes Yes Yes Yes Yes Desktop device No No No No No No No VESA mounting No No No No No No No Supply voltage Type of supply voltage AC, DC AC, DC AC, DC AC, DC AC, DC AC, DC AC, DC permissible range, lower limit (DC) 19. V 19. V 19. V 19. V 19. V 19. V 19. V permissible range, upper limit (DC) 8.8 V 8.8 V 8.8 V 8.8 V 8.8 V 8.8 V 8.8 V permissible range, lower limit (AC) 90 V 90 V 90 V 90 V 90 V 90 V 90 V permissible range, upper limit (AC) 64 V 64 V 64 V 64 V 64 V 64 V 64 V Interfaces Video interfaces analog video signal (VGA) Yes Yes Yes Yes Yes Yes Yes Degree and class of protection IP54 at front IP65 at front Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Standards, approvals, certificates UL Yes Yes Yes Yes Yes Yes Yes EAC (former Gost-R) No No No No No No No Marine approval Germanischer Lloyd (GL) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional American Bureau of Shipping (ABS) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Bureau Veritas (BV) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Det Norske Veritas (DNV) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Lloyds Register of Shipping (LRS) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Ambient conditions Max. ambient temperature 50 C 50 C 50 C 50 C 50 C 50 C 50 C Dimensions Width of the housing front 483 mm 483 mm 483 mm 483 mm 483 mm 483 mm 483 mm Height of housing front 310 mm 310 mm 310 mm 355 mm 310 mm 310 mm 310 mm Mounting cutout/device depth 450x90x54 450x90x54 450x90x54 450x90x54 450x90x54 450x90x54 450x90x54 (W x H x D) Device depth 55 mm 55 mm 55 mm 49 mm 55 mm 55 mm 55 mm /836 Siemens IK PI 015

58 Industry monitors and Thin Clients SIMATIC Flat Panels Technical specifications (continued) 6AV7861-3AA00-1AA0 6AV7861-3AB00-1AA0 6AV7861-3AB10-1AA0 6AV7861-3TA00-1AA0 6AV7861-3TB00-1AA0 6AV7861-3TB10-1AA0 Display Screen diagonal 19 in 19 in 19 in 19 in 19 in 19 in visible area (HxV) in mm 376 x x x x x x 301 Viewing angle 170 x x x x x x 170 On Screen Display (OSD) Yes Yes Yes Yes Yes Yes configuration Number of colors (bit levels) 16.7 million 16.7 million 16.7 million 16.7 million 16.7 million 16.7 million Number of colors ; 16.7 million ; 16.7 million ; 16.7 million ; 16.7 million ; 16.7 million ; 16.7 million Resolution (pixels) Horizontal image resolution Vertical image resolution Resolution (WxH in pixel) 180 x x x x x x 104 General features Brightness/contrast > 300 cd/m² / 300:1 > 300 cd/m² / 300:1 > 300 cd/m² / 300:1 > 300 cd/m² / 300:1 > 300 cd/m² / 300:1 > 300 cd/m² / 300:1 Control elements Function keys No No No No No No Operating mode integrated mouse cursor control No No No No No No Installation type/mounting Rack mounting possible Yes Yes Yes Yes Yes Yes Desktop device No No No No No No VESA mounting No No No No No No Supply voltage Type of supply voltage AC, DC AC, DC AC, DC AC, DC AC, DC AC, DC permissible range, lower limit (DC) 19. V 19. V 19. V 19. V 19. V 19. V permissible range, upper limit (DC) 8.8 V 8.8 V 8.8 V 8.8 V 8.8 V 8.8 V permissible range, lower limit (AC) 90 V 90 V 90 V 90 V 90 V 90 V permissible range, upper limit (AC) 64 V 64 V 64 V 64 V 64 V 64 V Interfaces Video interfaces analog video signal (VGA) Yes Yes Yes Yes Yes Yes Degree and class of protection IP54 at front IP65 at front Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners Yes; For screw mounting in 19" rack Yes; if mounted with the supplied latch fasteners IP0 rear Yes Yes Yes Yes Yes Yes Standards, approvals, certificates UL Yes Yes Yes Yes Yes Yes EAC (former Gost-R) No No No No No No Marine approval Germanischer Lloyd (GL) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional American Bureau of Shipping (ABS) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Bureau Veritas (BV) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Det Norske Veritas (DNV) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Lloyds Register of Shipping (LRS) Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Yes; Optional Ambient conditions Max. ambient temperature 45 C 45 C 45 C 45 C 45 C 45 C Dimensions Width of the housing front 483 mm 483 mm 483 mm 483 mm 483 mm 483 mm Height of housing front 400 mm 400 mm 400 mm 400 mm 400 mm 400 mm Mounting cutout/device depth 449 x 380 x x 380 x x 380 x x 380 x x 380 x x 380 x 56 (W x H x D) Device depth 57 mm 57 mm 57 mm 57 mm 57 mm 57 mm Siemens IK PI 015 /837

59 Industry monitors and Thin Clients SIMATIC Flat Panels Ordering data Article No. More information Flat Panel Monitor 6AV A A 0 Display size Operator functionality: Display devices A without operator functionality Touch screen (analog/resistive) T Power supply 4 VDC A (not for Extended versions since these always have AC and DC) 100 to 30 V AC B (incl. Euro power supply cable) and 4 V DC Version Standard, can be located 0 up to 5 m away Extended, can be located 1 up to 30 m away, marine approvals Dimmable background illumination Ex Additional information is available on the Internet at: Note: Do you need a specific modification or extension to the products described here? Then refer to "Customized Automation". There you will find information about additional and generally available sector-specific products as well as options for customer-specific modification and adaptation. Examples are: SIMATIC SCD monitor 1900 for portrait operation SIMATIC Flat Panels with 6" and 10" Touch Special versions Flat Panel Monitor 1" Key 15" Key PRO 15" Touch PRO 19" Touch Accessories Protective films For protecting the touch screen against dirt and scratches Pack with 10 units for 1" Touch for 15" Touch for 19" Touch Touch pen Undetachable pen for operation of the touch devices, mounting of the support on the control cabinet or directly on the PRO unit Connection cables for Standard, Extended and PRO versions Video (VGA) 3.0 m 5.0 m Video (DVI-D) 3.0 m 5.0 m USB for optional touch screen 3.0 m 5.0 m Connection cables for Extended and PRO versions Cable set 10 m (DVI-D, CAT5 cable (USB), USB transmitter module) Cable set 15 m (DVI-D, CAT5 cable (USB), USB transmitter module) Cable set 0 m (DVI-D, CAT5 cable (USB), USB transmitter module) Cable set 30 m (DVI-D, CAT5 cable (USB), USB transmitter module) 6AV7861-1KB10-1AA0 6AV7861-KB10-1AA0 6AV7861-5TB10-1BA0 6AV7861-6TB10-1BA0 6AV7671-BA00-0AA0 6AV7671-4BA00-0AA0 6AV767-1CE00-0AA0 6AV767-1JB00-0AA0 6AV7860-0AH30-0AA0 6AV7860-0AH50-0AA0 6AV7860-0BH30-0AA0 6AV7860-0BH50-0AA0 6AV7860-0CH30-0AA0 6AV7860-0CH50-0AA0 6AV7860-1EX1-0AA1 6AV7860-1EX1-5AA1 6AV7860-1EX-0AA1 6AV7860-1EX3-0AA1 /838 Siemens IK PI 015

60 Industry monitors and Thin Clients SCD monitors 1900 Overview The SIMATIC HMI SCD 1900 is a rugged, industry-standard PC monitor. It is used as an operator control unit in all types of industrial and standard PC, including for portrait mounting. Standard interfaces permit a wide range of possible applications. Built-in versions: Built-in unit (for control cabinets, control desks, and gantries) Built-in portrait for portrait mounting (for control cabinets, control desks and gantries) 19" built-in units (for 19" racks) Type of operator control: Panels with touch control Benefits Rugged industrial design, also designed for portrait operation: - High shock and vibration resistance as well as extremely high electromagnetic compatibility ensure failure safety and a long service life - Enclosure with IP65 degree of protection at the front, resistant against dust and humidity - Meets CE standard "Industry" No X-rays Lower energy requirement Fatigue-proof operation: - Large reading angle - Sharp and high-contrast graphic display - No flickering, uniform brightness - Automatic display adjustment (Auto Adjust) Configuration using on-screen display (OSD) Minimal space requirement and low weight Long service life Technical specifications 6AV786-TA00-1AA0 SCD 1900 General information Short designation Flat Panel 19" Touch Display Screen diagonal 19 in visible area (HxV) in mm 55 x 408 Viewing angle 160 x 170 Type TFT widescreen display, LED backlighting On Screen Display (OSD) Yes configuration Number of colors (bit levels) 4 bit Number of colors ; 16.7 million Resolution (pixels) Horizontal image resolution Vertical image resolution 900 Resolution (WxH in pixel) 1440 x 900 General features Brightness/contrast 300cd/m² / 1000:1 Brightness, max. 300 cd/m² Backlighting MTBF backlighting h (up to 50%, at 5 C) Installation type/mounting Rack mounting possible Yes Built-in unit Yes VESA mounting No Supply voltage Type of supply voltage DC permissible range, lower limit (DC) 1.6 V permissible range, upper limit (DC) 6.4 V Interfaces Video interfaces analog video signal (VGA) Yes DVI-D Yes Touch interfaces USB Yes Degree and class of protection IP65 at front Yes IP0 rear Yes Standards, approvals, certificates CE mark Yes; Industry CSA approval No UL Yes culus Yes Ambient conditions Storage/transport temperature Min. -0 C max. 60 C Shock testing Shock loading in operation 10 g Shock load during 10 g transport/storage Mechanics/material Type of housing (front) Aluminum Yes Weights Weight without packaging 6kg Siemens IK PI 015 /839

61 Industry monitors and Thin Clients SCD monitors 1900 Ordering data Article No. More information SCD monitor 1900 Portrait SCD monitor 1900 Accessories Cable for connecting to the graphics interface of the PC VGA cable, 3.0 m VGA cable, 5.0 m DVI-D cable, 3.0 m DVI-D cable, 5.0 m USB cable for connecting the touch screen 3.0 m 5.0 m External power supply for SCD V AC, Hz; incl. mounting accessories for optional installation at the device. 6AV786-TA00-1AA0 6AV7466-TA17-1AA0 6AV7860-0AH30-0AA0 6AV7860-0AH50-0AA0 6AV7860-0BH30-0AA0 6AV7860-0BH50-0AA0 6AV7860-0CH30-0AA0 6AV7860-0CH50-0AA0 6AV7860-AD06-0AA0 Additional information is available in the Internet under: /840 Siemens IK PI 015

62 Industry monitors and Thin Clients SIMATIC Industrial Thin Client Overview SIMATIC ITC Industrial Thin Clients are powerful operating units for flexible use in distributed visualization applications. All devices are equipped with high-resolution, brilliant widescreen displays, and due to the diverse communication protocols they can be used both for challenging machine-level operator control & monitoring and for the connection to control systems, e.g. in the SCADA environment. They can be used as (additional) operator stations on a SIMATIC Industrial PC, Panel PC, or server, and on a SIMATIC Panel. The following installation versions are available: SIMATIC ITC100 1" Touch SIMATIC ITC " Touch SIMATIC ITC " Touch SIMATIC ITC00 " Touch The SIMATIC HMI Thin Client Ex is available for hazardous areas. This device differs technically from the devices mentioned above. For more details, refer to catalog ST 80/ST PC, chapter 3. Benefits SIMATIC Industrial Thin Clients offer a wide range of possible applications, whether as additional operator stations for plant visualization on a Multi Panel or Comfort Panel, or as classical "client" which communicates with a server (e.g. SIMATIC IPC) using standard protocols such as RDP or VNC. The web browser functionality permits simple and fast access to any available web server in the network (e.g. S7 controller, intranet). Very cost-effective client-server architectures can be implemented with SIMATIC ITCs. A further advantage of SIMATIC ITCs: They communicate exclusively via Ethernet, thus permitting extremely simple and cost-effective coverage of even large distances to the server. The possibility of using SCADA and Office functionalities (e.g. WinCC, SAP, MS Excel) directly on-site on the machine supports the vertical integration of the data flow from higher-level systems all the way down to the machine level (e.g. warehouse utilization). With Multisession is it possible to switch between several servers connected to a SIMATIC ITC any time. On the other hand, of course, it is possible to connect several thin clients to a server to implement multi-user solutions. The SIMATIC ITC itself requires no installations, licenses, and additional software. The following communication options are supported Sm@rtServer for plant visualization with SIMATIC WinCC / SIMATIC WinCC flexible RDP (Remote Desktop Protocol) for SCADA and Office functionalities VNC (Virtual Network Computing) for remote operation of a PC Web browser functionality for operator control and monitoring of web-based applications As a Thin Client Unit on a SINUMERIK PCU/NCU Siemens IK PI 015 /841

63 Industry monitors and Thin Clients SIMATIC Industrial Thin Client Technical specifications 6AV6646-1AA-0AX0 6AV6646-1AB-0AX0 6AV6646-1AC-0AX0 6AV6646-1AD-0AX0 Display Screen diagonal 1.1 in 15.4 in 18.5 in 1.5 in Display width 61.1 mm 331. mm mm mm Display height 163. mm 07 mm 30.4 mm 9. mm Type TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting Number of colors Resolution (pixels) Horizontal image resolution Vertical image resolution General features PDF reader Yes Yes Yes Yes Backlighting Backlighting (type) LED, dimmable LED, dimmable LED, dimmable LED, dimmable Dimmable backlight Yes; % Yes; % Yes; % Yes; % Control elements Mouse/cursor control external mouse -USB Yes Yes Yes Yes Keyboard fonts external keyboard -USB Yes Yes Yes Yes Touch operation Design as touch screen Yes Yes Yes Yes - Touch screen (analog/resistive) Yes Yes Yes Yes Touch keyboard Yes Yes Yes Yes Installation type/mounting Built-in unit Yes Yes Yes Yes Supply voltage Type of supply voltage 4 V DC 4 V DC 4 V DC 4 V DC permissible range, lower limit (DC) 19. V 19. V 19. V 19. V permissible range, upper limit (DC) 8.8 V 8.8 V 8.8 V 8.8 V Input current Current consumption, max. 1. A 1.5 A 1.3 A. A Inrush current A²s 0.5 A² s 0.5 A² s 0.5 A² s 0.5 A² s Interfaces USB on the rear USB at the front Industrial Ethernet Transmission rate, max Mbit/s Mbit/s Mbit/s Mbit/s Number of industrial Ethernet interfaces Protocols Protocols (Ethernet) TCP/IP Yes Yes Yes Yes DHCP Yes Yes Yes Yes SNMP Yes Yes Yes Yes DCP Yes Yes Yes Yes LLDP Yes Yes Yes Yes WEB characteristics HTTP Yes Yes Yes Yes HTML Yes; HTML5 Yes; HTML5 Yes; HTML5 Yes; HTML5 XML Yes Yes Yes Yes CSS Yes Yes Yes Yes JavaScript Yes Yes Yes Yes Protocols (terminal link) Sm@rtService Yes Yes Yes Yes RDP Yes Yes Yes Yes VNC viewer Yes Yes Yes Yes Citrix No No No No SINUMERIK Yes Yes Yes No /84 Siemens IK PI 015

64 Industry monitors and Thin Clients SIMATIC Industrial Thin Client Technical specifications (continued) 6AV6646-1AA-0AX0 6AV6646-1AB-0AX0 6AV6646-1AC-0AX0 6AV6646-1AD-0AX0 Protocols PROFINET IO Device Services - PROFIenergy No No No No Degree and class of protection IP65 at front Yes Yes Yes Yes IP0 rear Yes Yes Yes Yes Standards, approvals, certificates CE mark Yes Yes Yes Yes KC approval Yes Yes Yes Yes culus Yes Yes Yes Yes RCM (former C-TICK) Yes Yes Yes Yes Use in hazardous areas culus Class I Zone 1 No No No No culus Class I Zone, Division Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon FM Class I Division Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Ambient conditions Min. ambient temperature 0 C 0 C 0 C 0 C Max. ambient temperature 50 C 50 C 45 C 45 C Storage/transport temperature [Fehlender Merkmalstext -0 C -0 C -0 C -0 C PMD_ACE481_001_000] [Fehlender Merkmalstext 60 C 60 C 60 C 60 C PMD_ACE483_001_000] Relative humidity Relative humidity during operation 90 % 90 % 90 % 90 % Software Web browser Yes Yes Yes Yes Configuration Configuration On-board Yes Yes Yes Yes Remote administration Yes; With Remote Configuration Center (RCC) as of V.0 Yes; With Remote Configuration Center (RCC) as of V.0 Yes; With Remote Configuration Center (RCC) as of V.0 Languages Online languages German Yes Yes Yes Yes English Yes Yes Yes Yes I/O/Options I/O devices USB memory Yes; USB storage medium can be connected Yes; USB storage medium can be connected Yes; USB storage medium can be connected Mechanics/material Type of housing (front) Aluminum Yes Yes Yes Yes Dimensions Housing diameter/depth (mm) Width 330 mm 415 mm 483 mm 560 mm Height 41 mm 310 mm 337 mm 380 mm Mounting cutout (W x H x D) Mounting cutout, width 310 mm 396 mm 465 mm 54 mm Mounting cutout, height 1 mm 91 mm 319 mm 36 mm Mounting cutout, depth 8 mm 75 mm 75 mm 75 mm Weights Weight without packaging 3.4 kg 5. kg 6.5 kg 7.1 kg Weight incl. packaging 4.1 kg 5.7 kg 7.1 kg 7.8 kg Yes; With Remote Configuration Center (RCC) as of V.0 Yes; USB storage medium can be connected Siemens IK PI 015 /843

65 Industry monitors and Thin Clients SIMATIC Industrial Thin Client Ordering data Article No. More information Industrial Thin Client SIMATIC ITC100 1" Touch device SIMATIC ITC " Touch device SIMATIC ITC " Touch device SIMATIC ITC00 " Touch device Accessories 6AV6646-1AA-0AX0 6AV6646-1AB-0AX0 6AV6646-1AC-0AX0 6AV6646-1AD-0AX0 See HMI accessories Additional information is available on the Internet at: /844 Siemens IK PI 015

66 Overview SIMATIC Identification systems RFID systems SIMATIC RF640R The integrated processing logic of the reader enables numerous functions to be executed in the device itself. For example, the reader offers extensive, intelligent filter functions, a parameterizable state machine for forwarding the data, the automatic control of the digital outputs for signaling functions, and the extensive configuration of response message frames. The advantage: Thanks to its intelligence, this considerably reduces the cost for additional software modules (RFID middleware). The reader is configured by means of the easy-to-use SIMATIC RF-MANAGER Basic software, which is provided on a free CD supplied with each reader. Data communication takes place via an XML protocol with TCP/IP; the reader provides an Ethernet interface for this purpose. The protocol is compatible with the SIMATIC RF670R. SIMATIC RF640R is a powerful UHF reader with integral antenna that is suitable for applications at single recording stations, in conveyor systems or production plants. Due to its high maximum transmission power of up to W ERP (ETSI) / 4 W EIRP (FCC), longer ranges can also be achieved. The high degree of protection of the overall system is a guarantee for problem-free use, even under the most difficult environmental conditions. Instead of the integral antenna, an external antenna of the RF600 series (SIMATIC RF60A, RF640A, RF64A, RF660A) can be used. The reader offers digital inputs (4 V) and digital outputs (typ. 4 V/0.5 A) that have protection circuits for industrial use. Technical specifications Application The stationary SIMATIC RF640R UHF reader with its integral antenna is suitable for applications in production (with PC/IT interface), production-level logistics, distribution, supply chain management, asset management, service processes or material flow control. The digital inputs and outputs (DI/DO) are used for simple process interfacing (sensors, actuators). The SIMATIC RF640R supports the established EPCglobal Class 1, Gen standard and is offered in three versions: compliant with ETSI for Europe, compliant with FCC for USA/ Canada, and compliant with CMIIT for China. Article No. 6GT811-3BA00-0AA0 6GT811-3BA00-1AA0 6GT 811-3BA00-AA0 Product-type designation RF640R ETSI reader RF640R FCC reader RF640R reader CMIIT Suitability for installation RF600 transponder, for connecting to Ethernet networks RF600 transponder, for connecting to Ethernet networks RF600 transponder, for connecting to Ethernet networks Wireless frequencies Operating frequency MHz MHz MHz Transmit power mw mw mw Effective radiant power for each external 000 mw mw antenna maximum Equivalent isotropic radiant power for mW - each external antenna maximum Electrical data Range maximum 8m 8m 8m Range note Refer to RF600 system manual, overrange is possible Protocol for radio transmission EPCglobal Class 1 Gen / ISO C Transfer rate with radio transmission maximum Refer to RF600 system manual, overrange is possible EPCglobal Class 1 Gen / ISO C 30 kbit/s 30 kbit/s 30 kbit/s Refer to RF600 system manual, overrange is possible EPCglobal Class 1 Gen / ISO C Product property multitag-capable Yes Yes Yes Polarization Internal: circular, external: according to antenna Internal: circular, external: according to antenna Internal: circular, external: according to antenna Transmission time for user data for write access per byte typical 6.3 ms 6.3 ms 6.3 ms for read access per byte typical 1ms 1ms 1ms Siemens IK PI 015 /845

67 SIMATIC Identification systems RFID systems SIMATIC RF640R Technical specifications (continued) Article No. 6GT811-3BA00-0AA0 6GT811-3BA00-1AA0 6GT 811-3BA00-AA0 Product-type designation RF640R ETSI reader RF640R FCC reader RF640R reader CMIIT Interfaces Number of external antennas Design of electrical connection for external antenna(s) for supply voltage M1, 4-pin, female connector M1, 4-pin, female connector M1, 4-pin, female connector Standard for interfaces Ethernet Ethernet Ethernet for communication Design of electrical connection for communications interface Push-pull RJ45 Push-pull RJ45 Push-pull RJ45 at the digital inputs/outputs M1, 8-pin, female connector M1, 8-pin, female connector M1, 8-pin, female connector Number of digital inputs Number of digital outputs Mechanical data Material Aluminum, ABS (GF0) Aluminum, ABS (GF0) Aluminum, ABS (GF0) Color Silver/anthracite Silver/anthracite Silver/anthracite Mounting distance for metal surfaces 0mm 0mm 0mm recommended minimum Supply voltage, current consumption, power loss Supply voltage for DC rated value 4 V 4 V 4 V minimum 0 V 0 V 0 V maximum 30 V 30 V 30 V Consumed current at 4 V DC typical 0.45 A 0.45 A 0.45 A maximum 1.5 A 1.5 A 1.5 A Permitted ambient conditions Ambient temperature during operating C C C during storage C C C during transport C C C Ambient condition for (standard) operation mode With operating temperature below -0 C: Warming-up time at least 10 minutes With operating temperature below -0 C: Warming-up time at least 10 minutes With operating temperature below -0 C: Warming-up time at least 10 minutes Protection class IP IP65 IP65 IP65 Resistance against shock EN , EN EN , EN EN , EN Resistance against shock 500 m/s² 500 m/s² 500 m/s² Resistance against vibration 00 m/s² 00 m/s² 00 m/s² Design, dimensions and weight Width 193 mm 193 mm 193 mm Height 5 mm 5 mm 5 mm Depth 5 mm 5 mm 5 mm Net weight.0 kg.01 kg 1.99 kg Mounting type 4 x M6 screws, Vesa 100 with 4 x M4 screws 4 x M6 screws, Vesa 100 with 4 x M4 screws 4 x M6 screws, Vesa 100 with 4 x M4 screws Cable length of antenna cable minimum 3m 3m 3m maximum 0 m 0 m 0 m Product properties, functions, components general Type of display 3-color LED 3-color LED 3-color LED Product feature silicon-free Yes Yes Yes Standards, specifications, approvals Verification of suitability Wireless acc. to R&TTE guideline, CE, IEC Wireless according to FCC, IC (Canada), culus Wireless according to CMIIT Accessories optional: External antenna optional: External antenna optional: External antenna /846 Siemens IK PI 015

68 SIMATIC Identification systems RFID systems SIMATIC RF640R Ordering data Article No. More information SIMATIC RF640R reader (ETSI) UHF RFID reader for frequencies from 865 to 868 MHz with integrated antenna, suitable for inclusion in PC systems via Ethernet with TCP/IP and XML protocol. SIMATIC RF640R reader (FCC) UHF RFID reader for frequencies from 90 to 98 MHz with integrated antenna, suitable for inclusion in PC systems via Ethernet with TCP/IP and XML protocol. SIMATIC RF640R reader (CMIIT) UHF RFID reader for frequencies from 90 to 95 MHz with integrated antenna, suitable for inclusion in PC systems via Ethernet with TCP/IP and XML protocol. Accessories DI/DO cable For the connection of digital sensors and actuators to SIMATIC RF640R. M1 connector on reader side, open stranded wires on the sensor side. DI/DO cable, PUR material, black, shielded, M1, 8 x 0.14 mm², length 5 m. Set of protective caps For achieving IP65 degree of protection if not all connections on the reader are assigned. Content: 3x protective caps for antenna connection, 1x protective cap for DI/DO connection; design: Metal. Wide-range power supply Primary side: V AC, V DC, secondary side: 4 V DC, 3 A, with no-load protection and continuous short-circuit protection. EU connector version UK connector version US connector version Cable for wide-range power supply 4 V DC, material: PUR, length 5 m NOTICE: This cable is not suitable for SIMATIC RF660R. Ethernet connection Twisted connecting cable, IP65 on reader side, length 10 m. Push-pull cable connector for RJ45, not pre-assembled. Covers for push-pull sockets, RJ45, 5 units per pack. Price per pack. 6GT811-3BA00-0AA0 6GT811-3BA00-1AA0 6GT811-3BA00-AA0 6GT891-0DH50 6GT898-4AA00 6GT898-0AA00 6GT898-0AA10 6GT898-0AA0 6GT891-0NH50 6GT891-1HN10 6GK1901-1BB10-6AA0 6ES7194-4JD50-0AA0 All current approvals can be found on the Internet at: Siemens IK PI 015 /847

69 SIMATIC Identification systems RFID systems SIMATIC RF670R Overview The integrated processing logic of the reader enables numerous functions of the higher-level software layers to be executed in the device itself. For example, the reader offers extensive, intelligent filter functions, a parameterizable state machine for forwarding the data, the automatic control of the digital outputs for signaling functions, and the extensive configuration of response message frames. The advantage: Thanks to its intelligence, this considerably reduces the cost for additional software modules (RFID middleware). The reader is configured by means of the easy-touse SIMATIC RF-MANAGER Basic software, which is provided on a free CD supplied with each reader. Data communication for the RF670R is performed by means of an XML protocol with TCP/IP; the reader provides an Ethernet interface for this purpose. SIMATIC RF670R is a high-performance RFID reader with four antenna connections which can be configured as required for individual read stations, detecting at conveyor systems, or as gates. The high transmit power of up to W ERP / 4 W EIRP (dependent on antenna and cable) permits large ranges of up to 10 m in gate applications. The high degree of protection of the overall system is a guarantee for problem-free use, even under the most difficult environmental conditions. Due to the monostatic antenna principle, as many as four independent read stations can be implemented. All antennas of the RF600 series are supported (SIMATIC RF60A, RF640A, RF64A, RF660A). The reader offers 4 digital inputs (4 V) and 4 digital outputs (typ. 4 V/0.5 A) that have protection circuits for industrial use. Technical specifications Application With up to four antennas, the stationary SIMATIC RF670R UHF portal reader is suitable for applications in production (with PC/IT interface), production-level logistics, distribution, supply chain management, asset management, service processes, or material flow control. The digital inputs and outputs (DI/DO) are used for simple process interfacing (sensors, actuators). The SIMATIC RF670R supports the established EPCglobal Class 1, Gen standard and is offered in three versions: compliant with ETSI for Europe, compliant with FCC for USA/ Canada, and compliant with CMIIT for China. Article No. 6GT811-0AB00-0AA0 6GT811-0AB00-1AA0 6GT811-0AB00-AA0 Product-type designation RF670R ETSI reader RF670R FCC reader RF670R CMIIT reader Suitability for installation RF600 transponder, for connecting to Ethernet networks RF600 transponder, for connecting to Ethernet networks RF600 transponder, for connecting to Ethernet networks Wireless frequencies Operating frequency MHz MHz MHz Transmit power mw mw mw Effective radiant power 000 mw mw for each external antenna maximum Equivalent isotropic radiant power mw - for each external antenna maximum Electrical data Range maximum 8m 8m 8m Range note Refer to RF600 system manual, overrange is possible Protocol for radio transmission EPCglobal Class 1 Gen / ISO C Transfer rate with radio transmission maximum Refer to RF600 system manual, overrange is possible EPCglobal Class 1 Gen / ISO C 30 kbit/s 30 kbit/s 30 kbit/s Product property multitag-capable Yes Yes Yes Transmission time for user data for write access per byte typical 6.3 ms 6.3 ms 6.3 ms for read access per byte typical 1ms 1ms 1ms Refer to RF600 system manual, overrange is possible EPCglobal Class 1 Gen / ISO C /848 Siemens IK PI 015

70 SIMATIC Identification systems RFID systems SIMATIC RF670R Technical specifications (continued) Article No. 6GT811-0AB00-0AA0 6GT811-0AB00-1AA0 6GT811-0AB00-AA0 Product-type designation RF670R ETSI reader RF670R FCC reader RF670R CMIIT reader Interfaces Design of the electrical connection RP-TNC RP-TNC RP-TNC for external antenna(s) Number of external antennas Design of electrical connection for supply voltage M1, 4-pin, female connector M1, 4-pin, female connector M1, 4-pin, female connector Standard for interfaces for communication Ethernet Ethernet Ethernet for communications interface Push-pull RJ45 Push-pull RJ45 Push-pull RJ45 at the digital inputs/outputs M1, 1-pin, female connector M1, 1-pin, female connector M1, 1-pin, female connector Number of digital inputs Number of digital outputs Mechanical data Material Aluminum, ABS (GF0) Aluminum, ABS (GF0) Aluminum, ABS (GF0) Color Silver/anthracite Silver/anthracite Silver/anthracite Supply voltage, current consumption, power loss Supply voltage for DC rated value 4 V 4 V 4 V minimum 0 V 0 V 0 V maximum 30 V 30 V 30 V Consumed current at 4 V with DC typical 0.45 A 0.45 A 0.45 A maximum A A A Permitted ambient conditions Ambient temperature during operating C C C during storage C C C during transport C C C Protection class IP IP65 IP65 IP65 Resistance against shock EN , EN EN , EN EN , EN Resistance against shock 500 m/s² 500 m/s² 500 m/s² Resistance against vibration 00 m/s² 00 m/s² 00 m/s² Design, dimensions and weight Width 193 mm 193 mm 193 mm Height 5 mm 5 mm 5 mm Depth 5 mm 5 mm 5 mm Net weight 1.8 kg 1.8 kg 1.8 kg Mounting type 4 x M6 screws, Vesa 100 with 4 x M4 screws 4 x M6 screws, Vesa 100 with 4 x M4 screws 4 x M6 screws, Vesa 100 with 4 x M4 screws Cable length of antenna cable minimum 3m 3m 3m maximum 0 m 0 m 0 m Product properties, functions, components general Type of display 3-color LED 3-color LED 3-color LED Product feature silicon-free Yes Yes Yes Standards, specifications, approvals Verification of suitability Wireless acc. to R&TTE guideline, CE, IEC Wireless according to FCC, IC (Canada), culus Wireless according to CMIIT Accessories Accessories One or 4 external antennas One or 4 external antennas One or 4 external antennas Siemens IK PI 015 /849

71 SIMATIC Identification systems RFID systems SIMATIC RF670R Ordering data Article No. More information SIMATIC RF670R reader (ETSI) UHF RFID reader for frequencies from 865 to 868 MHz for connecting up to four external antennas, suitable for inclusion in PC systems via Ethernet with TCP/IP and XML protocol. SIMATIC RF670R reader (FCC) UHF RFID reader for frequencies from 90 to 98 MHz for connecting up to four external antennas, suitable for inclusion in PC systems via Ethernet with TCP/IP and XML protocol. SIMATIC RF670R reader (CMIIT) UHF RFID reader for frequencies from 90 to 95 MHz for connecting up to four external antennas, suitable for inclusion in PC systems via Ethernet with TCP/IP and XML protocol. Accessories Note: For proper functioning of the SIMATIC RF670R reader, we recommend using the SIMATIC RF60A / 640A / 64A / 660A antennas. DI/DO cable For the connection of digital sensors and actuators to SIMATIC RF670R. M1 connector on reader side, open stranded wires on the sensor side. DI/DO cable, PUR material, black, shielded, M1, 1 x 0.14 mm², length 5 m. Wide-range power supply Primary side: V AC, V DC, secondary side: 4 V DC, 3 A, with no-load protection, with continuous short-circuit protection EU connector version UK connector version US connector version Cable for wide-range power supply 4 V DC, PUR material, length 5 m. NOTICE: This cable is not suitable for SIMATIC RF660R. Ethernet connection Twisted connecting cable, IP65 on reader side, length 10 m. Push-pull cable connector for RJ45, not pre-assembled. Covers for push-pull sockets, RJ45, 5 units per pack. Price per pack. Set of protective caps For achieving IP65 degree of protection if not all connections on the reader are assigned. Content: 3x protective caps for antenna connection, 1x protective cap for DI/DO connection; design: Metal. 6GT811-0AB00-0AA0 6GT811-0AB00-1AA0 6GT811-0AB00-AA0 6GT891-0CH50 6GT898-0AA00 6GT898-0AA10 6GT898-0AA0 6GT891-0NH50 6GT891-1HN10 6GK1901-1BB10-6AA0 6ES7194-4JD50-0AA0 6GT898-4AA00 All current approvals can be found on the Internet at: /850 Siemens IK PI 015

72 Overview SIMATIC Identification systems RFID systems SIMATIC RF180C/RF18C Application The Ethernet-based communication modules have been specially designed for a wide range of applications in industrial automation and logistics. Due to their high IP67 degree of protection, the SIMATIC RF180C/RF18C and RFID 181EIP can be installed in the process outside the control cabinet. Main applications for SIMATIC RF180C/RF18C and RFID 181EIP: Mechanical engineering, automation systems, conveyor systems Ancillary assembly lines in the automotive industry / suppliers Small assembly lines Design SIMATIC RF180C / RF18C and RFID 181EIP are communication modules for direct connection of SIMATIC identification systems to PROFINET IO/Ethernet and Ethernet/IP. The readers (SLGs) of the RFID systems MOBY D/U, SIMATIC RF00 / RF300 / RF600 as well as the MV400 code reading systems (RF180C and RFID 181EIP only) can be operated on the communication modules. Due to their high degree of protection and ruggedness, the SIMATIC RF180C / RF18C and RFID 181EIP are ideally suitable for use at the machine level. The uniform plug-in connection system ensures rapid commissioning. Benefits Two parallel reader channels ensure real-time mode at dynamic read points. Reader connection using an 8-pin M1 connector for fast installation of all components. Different connection systems to suit any application: - M1, 7/8", the well-proven round connectors. - Push-pull connectors for quick assembly with RJ45 data connectors and 4 V connectors. Easy changeover from PROFIBUS applications to PROFINET with SIMATIC RF180C thanks to software compatibility. The integrated switch allows several PROFINET/Ethernet modules to be installed in a star or bus topology. Each application can then be set up quickly and inexpensively. Powerful hardware ensures rapid data communication with the reader (SLG). Consequently, data is available for the application even faster. Simple firmware downloading in the case of function expansions and error rectification ensures high availability of the identification system. Adjustable and parameterizable identification-systemspecific diagnostics facilitate easy commissioning and troubleshooting. A broad selection of pre-assembled connecting cables can be ordered for connecting PROFINET/Ethernet and readers to SIMATIC RF180C/RF18C. This saves time and money during installation and assures better quality. PROFINET IO Master module e.g. S7-400 with CP PC PROFINET Industrial Ethernet 4 V for RF180C and SLG to other PROFINET/Ethernet bus nodes SIMATIC RF180C/RF18C. Reader / SLG RFID integration into PROFINET/Ethernet network Transponder 1. Reader / SLG G_FS10_XX_008 Siemens IK PI 015 /851

73 SIMATIC Identification systems RFID systems SIMATIC RF180C/RF18C Function The SIMATIC RF180C / RF18C and RFID 181EIP communication modules consist of a basic module and a connection block that must be ordered separately. The connection block is available in three versions: M1, 7/8" (5-pole): PROFINET/Ethernet is connected by means of an M1 connector, the power supply is connected by means of a 5-pole 7/8" connector. There are connections each for PROFINET/Ethernet as well as for the power supply. This ensures that the SIMATIC RF180C/RF18C can be connected to additional bus nodes without the need for external distributors. The removable connection block allows a base module to be replaced without interrupting the supply voltage to other bus stations. Push-pull connector (according to IEC 61918): PROFINET/Ethernet and the power supply are connected by means of a push-pull connector. There are connections each for PROFINET/Ethernet as well as for the power supply. This ensures that the SIMATIC RF180C/RF18C can be connected to additional bus nodes without the need for external distributors. The supply voltage connectors can conduct currents of up to 1 A (1L+ and L+). The removable connection block allows a base module to be replaced without interrupting the supply voltage to other bus stations. M1, 7/8" (4-pole; not recommended for RF180C): Ethernet is connected by means of an M1 connector, the power supply is connected by means of a 4-pole 7/8" connector. There are connections for Ethernet and one connection is available for the power supply. This connection block can be used in applications where the 5-pole 7/8" connector is already being used for other functions and therefore cannot be used for the power supply. A pre-assembled reader cable is used to connect one or two readers to the communication module. The standard cable length is m. If other reader cable lengths are required, an extension cable from to 50 m in length can be used. The cable can also be assembled by the customer as required. The data in the transponder can be accessed as follows: Direct addressing via absolute addresses. Error messages and operating states (transponder in the field, transmission, etc.) are indicated additionally by means of LEDs and simplify commissioning and service. SIMATIC RF180C/RF18C and RFID 181EIP have two reader interfaces from which the readers are also supplied with voltage. In the communication module, the power supply of the readers has an electronic fuse. The maximum permissible current per communication module for the readers is 1 A. It is of no importance here whether the current is drawn by 1 or readers. SIMATIC RF180C The SIMATIC RF180C is designed for use in PROFINET networks. SIMATIC RF180C is integrated in SIMATIC STEP 7 via the GSDML file. SIMATIC RF180C can then be configured via the SW tool HW Config of SIMATIC Manager or another PROFINET tool. The application accesses the tag via FB45. FB45 accesses the tag/data Matrix Code via absolute addresses. For large volumes of data and complex tag operations, the FB45 can process chained commands. Data is exchanged between SIMATIC RF180C and the application by means of acyclic data records. This ensures that a large quantity of data can be transferred from/to SIMATIC RF180C without loading the bus cycle. This is advantageous when large volumes of data are being transferred. SIMATIC RF180C can also process chained tag commands in this mode extremely quickly. SIMATIC RF18C The SIMATIC RF18C is designed for use in Ethernet networks based on TCP/IP. The IP address of the SIMATIC RF18C is set using the "Primary Setup Tool". The RF18C is then ready for operation. This tool can be downloaded from Communication with the SIMATIC RF18C is implemented using XML commands. XML commands have a very simple structure. This makes programming of the RF18C under any operating system very easy. The simple command command set of the RF18C can also be programmed easily in any Ethernet-capable controller. RFID 181EIP The communication module RFID 181EIP is for use in Ethernet/ IP networks. A DHCP server automatically assigns an IP address to the RDID 181EIP. Alternatively, the user can assign issue static IP addresses on the DHCP server. The standard tool for assigning IP addresses is called the BOOTP/DHCP server and is included in the RSLinx software package. The RFID 181EIP communicates with the reader by means of implicit and explicit messages. Commands and results are transferred with explicit messages. The user sets up the commands directly in the application program. /85 Siemens IK PI 015

74 SIMATIC Identification systems RFID systems SIMATIC RF180C/RF18C Technical specifications Article No. 6GT00-0JD00 6GT00-0JD10 6GT00-0JD0 Product-type designation RF180C communication module RF18C communication module RFID 181EIP communication module Suitability for installation PROFINET in conjunction with RF00/300/600, MOBY D/E/I/U, MV Industrial Ethernet in conjunction with RF00/300/600, MOBY D/U Ethernet/IP in conjunction with RF00/300/600, MOBY D/E/I/U, MV Transmission rate with Industrial Ethernet Mbit/s Mbit/s Mbit/s at point-to-point connection serial 115. kbit/s 115. kbit/s 115. kbit/s maximum Interfaces Design of interface for point-to-point RS4 RS4 RS4 connection Number of readers connectable Design of the electrical connection (according to the connection block) (according to the connection block) (according to the connection block) the Industrial Ethernet Interface Design of electrical connection (according to the connection block) (according to the connection block) (according to the connection block) for supply voltage Version of the interface to the reader M1, 8-pin M1, 8-pin M1, 8-pin for communication Mechanical data Material Thermoplastic (Valox 467, fiberglass reinforced) Thermoplastic (Valox 467, fiberglass reinforced) Thermoplastic (Valox 467, fiberglass reinforced) Color IP Basic 714 IP Basic 714 IP Basic 714 Tightening torque of screw for 3N m 3N m 3N m mounting the equipment maximum Supply voltage, current consumption, power loss Supply voltage for DC rated value 4 V 4 V 4 V minimum 0 V 0 V 0 V maximum 30 V 30 V 30 V Current consumed at 4 V DC without connected devices typical 0.1 A 0.1 A 0.1 A including connected devices 1.1 A 1.1 A 1.1 A maximum Permitted ambient conditions Ambient temperature during operating 0 60 C 0 60 C 0 60 C during storage C C C during transport C C C Protection class IP IP 67 IP 67 IP 67 Resistance against shock According to IEC According to IEC According to IEC Resistance against shock 300 m/s² 300 m/s² 300 m/s² Resistance against vibration 100 m/s² 100 m/s² 100 m/s² Siemens IK PI 015 /853

75 SIMATIC Identification systems RFID systems SIMATIC RF180C/RF18C Technical specifications (continued) Article No. 6GT00-0JD00 6GT00-0JD10 6GT00-0JD0 Product-type designation RF180C communication module RF18C communication module RFID 181EIP communication module Design, dimensions and weight Width 60 mm 60 mm 60 mm Height 30 mm 30 mm 30 mm Depth 10 mm 10 mm 10 mm Net weight 0.1 kg 0.1 kg 0.1 kg Mounting type x M5 screws x M5 screws x M5 screws Cable length for RS 4 interface 1000 m 1000 m 1000 m maximum Product properties, functions, components general Type of display 4 LEDs per reader connection, 4 LEDs for device status 4 LEDs per reader connection, 4 LEDs for device status 4 LEDs per reader connection, 4 LEDs for device status Product function Media Redundancy Protocol (MRP) No No No transponder file handler Yes No Yes can be addressed Protocol is supported -LLDP Yes No No - PROFINET IO protocol Yes No No -TCP/IP No Yes No EtherNet/IP protocol No No Yes Product functions management, configuration Type of parameterization GSDML XML EDS file Type of programming FB 45, FB 55, Ident profile (PIB) XML commands Data records via implicit/explicit messages Type of computer-mediated communication acyclic communication XML Implicit/explicit messaging Standards, specifications, approvals Verification of suitability CE, FCC, culus, PNO: Conformance CE, FCC, culus CE, FCC, culus Class B Accessories Accessories Connection block M1 d-coded, 7/8'' 5-pin or push-pull Connection block M1 d-coded, 7/8'' 5-pin or push-pull or M1 d-coded, 7/8'' 4-pin Connection block M1 d-coded, 7/8'' 5-pin or push-pull or M1 d-coded, 7/8'' 4-pin /854 Siemens IK PI 015

76 SIMATIC Identification systems RFID systems SIMATIC RF180C/RF18C Technical specifications (continued) Article No. 6GT00-1JD00 6GT00-JD00 6GT00-4JD00 Product-type designation Connection block for RF18xC, Connection block for RF18xC, Connection block for RF18xC, M1, 7/8'' 5-pin push-pull M1, 7/8'' 4-pin Suitability for installation Connection block for RF180C, RF18C, RFID 181EIP Connection block for RF180C, RF18C, RFID 181EIP Connection block for RF180C, RF18C, RFID 181EIP Transmission rate Mbit/s Mbit/s Mbit/s with Industrial Ethernet Interfaces Design of the electrical connection M1, d-coded push-pull, RJ 45 M1, d-coded the Industrial Ethernet Interface Design of electrical connection 7/8'' 5-pin push-pull, 5-pin 7/8'' 4-pin for supply voltage Mechanical data Material Die-cast zinc Thermoplastic Die-cast zinc (Valox 467, fiberglass reinforced) Color Silver IP Basic 714 Silver Tightening torque of screw for 1.3 N m 1N m 1.3 N m mounting the equipment maximum Supply voltage, current consumption, power loss Supply voltage for DC rated value 4 V 4 V 4 V minimum 0 V 0 V 0 V maximum 30 V 30 V 30 V Continuous current for loop-through to 8A 1 A 8A further bus nodes with DC, maximum Permitted ambient conditions Ambient temperature during operating 0 60 C 0 60 C 0 60 C during storage C C C during transport C C C Protection class IP IP 67 IP 67 IP 67 Resistance against shock According to IEC According to IEC According to IEC Resistance against shock 300 m/s² 300 m/s² 300 m/s² Resistance against vibration 100 m/s² 100 m/s² 100 m/s² Design, dimensions and weight Width 60 mm 60 mm 60 mm Height 4 mm 70 mm 4 mm Depth 79 mm 85 mm 79 mm Net weight 0.3 kg 0.1 kg 0.3 kg Mounting type 4 screws included 4 screws included 4 screws included Product properties, functions, components general Type of display 4 LEDs for Ethernet status 4 LEDs for Ethernet status 4 LEDs for Ethernet status Accessories Accessories Siemens IK PI 015 /855

77 SIMATIC Identification systems RFID systems SIMATIC RF180C/RF18C Ordering data Article No. Article No. SIMATIC RF180C 6GT00-0JD00 communication module For PROFINET, for connecting readers, without a connection block. SIMATIC RF18C 6GT00-0JD10 communication module For Ethernet, for connecting readers, without a connection block. Communication module SIMATIC 6GT00-0JD0 RFID 181EIP For Ethernet/IP, for connecting readers, without a connection block. PROFINET connection block 6GT00-1JD00 For SIMATIC RF180C/RF18C, M1 d-coded, 7/8" (5-pole). PROFINET connection block 6GT00-JD00 For SIMATIC RF180C/RF18C, push-pull RJ45. PROFINET connection block 6GT00-4JD00 For SIMATIC RF18C, RFID 181EIP, M1 d-coded, 7/8" (4-pole). Accessories for network connection M1, 7/8" (5-pole) IE M1-180/M1-180 connecting cable Pre-assembled IE FC TP trailing cable GP x (PROFINET Type C), with two 4-pin M1 plugs (D-coded), maximum length 85 m, IP65/IP67 degree of protection. Lengths: 0.3 m 6XV1870-8AE m 6XV1870-8AE50 1 m 6XV1870-8AH m 6XV1870-8AH15 m 6XV1870-8AH0 3 m 6XV1870-8AH30 5 m 6XV1870-8AH50 10 m 6XV1870-8AN10 15 m 6XV1870-8AN15 7/8" connecting cable to power supply Pre-assembled with two 5-pin 7/8" male and female connectors. Lengths: 0.3 m 6XV18-5BE m 6XV18-5BE50 1 m 6XV18-5BH m 6XV18-5BH15 m 6XV18-5BH0 3 m 6XV18-5BH30 5 m 6XV18-5BH50 10 m 6XV18-5BN10 15 m 6XV18-5BN15 PROFINET M1 6GK1901-0DB0-6AA0 plug-in connectors Rugged metal housing; axial cable outlet; D-coded. 7/8" cable connector, for voltage Pack with 5 units, minimum ordering quantity 1 pack. With male insert 6GK1905-0FA00 With female insert 6GK1905-0FB00 IE M1 control cabinet bushing 6GK1901-0DM0-AA5 For conversion from M1 (D-coded) to RJ45, pack with 5 units, minimum ordering quantity 1 pack. IE Connecting Cable M1-180/IE 6XV1871-5TH0 FC RJ45 Plug 145 Pre-assembled IE FC TP trailing cable GP x (PROFINET type C) with M1 plug (D-coded) and IE FC RJ45 plug, IP65/IP67 degree of protection, length m. IE FC RJ45 PLUG 180 RJ45 plug 6GK1901-1BB10-AA0 With rugged metal housing and FC connection system, straight cable outlet. Sealing caps 7/8" 6ES7194-3JA00-0AA0 Pack with 10 units, minimum ordering quantity 1 pack. Accessories for push pull RJ45 network connection Push-pull cable connector 6GK1907-0AB10-6AA0 for 1L+/L+ Unassembled. Push-pull cable connector 6GK1901-1BB10-6AA0 for RJ45 Unassembled. Cover caps for push-pull 6ES7194-4JA50-0AA0 female connectors (1L+/ L+), pack of 5. Cover caps for push-pull 6ES7194-4JD50-0AA0 female connectors RJ45, pack of 5. Accessories for network connection M1, 7/8" (4-pole) Network wiring with M1 Accessories as for M1, 7/8" (5-pole) Power supply with 7/8" (4-pole) No cables and connectors from Siemens Accessories for PROFINET bus components SCALANCE X04-6GK504-BB10-AA3 Industrial Ethernet Switch Industrial Ethernet switches with integral SNMP access, Web diagnostics, copper cable diagnostics, and PROFINET diagnostics for configuring line, star and ring topologies, with integrated redundancy manager (exception: SCALANCE X08PRO), including operating instructions, Industrial Ethernet network manual, and configuration software on CD-ROM. With electrical and optical ports for glass multi-mode fiber-optic cable up to 5 km: four 10/100 Mbit/s RJ45 ports and two fiber-optic ports. SCALANCE X04IRT PRO 6GK504-0JA00-BA6 Industrial Ethernet switch Managed Industrial Ethernet switch, isochronous real-time, LED diagnostics, fault signaling contact with SET button, redundant power supply, incl. operating instructions, Industrial Ethernet network manual, and configuration software on CD-ROM. Four 10/100 Mbit/s RJ45 push-pull ports /856 Siemens IK PI 015

78 SIMATIC Identification systems RFID systems SIMATIC RF180C/RF18C Ordering data Article No. Article No. Accessories for PROFINET bus components IE FC TP standard cable GP x 6XV1840-AH10 4-core, shielded TP installation cable for connection to IE, FC outlet RJ45/IE FC RJ45 plug, PROFINET-compatible, with UL approval, sold by the meter, max. delivery unit 1000 m, minimum ordering quantity 0 m. Power line 6XV1830-8AH10 5-core, 5 x 1.5 mm, trailing type, sold by the meter, minimum ordering quantity 0 m, maximum ordering quantity 1000 m. General accessories Stainless steel screws 6GT090-0VB00 for connection blocks Optional screws made of V4A steel for securing the connection blocks on the basic module. For use in wet areas. Pack with 40 units is sufficient for 10 connection blocks. Accessories for RFID MOBY U reader cable PUR material, CMG approval, suitable for cable carriers. Lengths: m 6GT091-4FH0 5 m 6GT091-4FH50 MOBY D reader cable 6GT691-4FH0 PUR material, CMG approval, suitable for cable carriers, m. Reader cable for SIMATIC RF00 / RF300 / RF600 / MV40 / MV440 Or extension cable MOBY U/D and SIMATIC RF00 / RF300 / RF600 / MV400, PUR material, CMG approval, suitable for cable carriers, straight connector. Lengths: m 6GT891-4FH0 5 m 6GT891-4FH50 10 m 6GT891-4FN10 0 m 6GT891-4FN0 50 m 6GT891-4FN50 m, plug angled at reader 6GT891-4JH0 5 m, plug angled at reader 6GT891-4JH50 Sealing caps M1 for 3RX980-0AA00 unused reader connections Minimum ordering quantity 10 units. DVD "RFID Systems Software & 6GT080-AA0 Documentation" Siemens IK PI 015 /857

79 SIMATIC Identification systems Code reading systems SIMATIC MV40 Overview The SIMATIC MV40 is a particularly compact code reading system suitable for close-up to mid-range reading distances (approx. 10 mm to 400 mm). SIMATIC MV40 has been specifically designed for detecting and evaluating a variety of machine readable codes in the packaging industry (e.g. F&B, pharmaceuticals, and tobacco) and industrial production (e.g. automotive, electronics, and solar). The list of readable codes includes all standard matrix codes and bar codes which can be reliably detected - mostly independent of the printing technology applied and carrier medium used. One key feature of the unit is its ability to read data matrix codes (DMC). The SIMATIC MV40 device family is flexible, reliable and easy to use. Highlights at a glance: Compact design with IP67 degree of protection. Variety of lenses with variable reading distances. Integrated high-performance lighting. Web server technology: Parameterizable with regular Web browser. Interfaces: Ethernet, PROFINET, RS3, DI/DO, and direct connection to RFID communication modules (ASM). Exceptionally high reading speeds, depending on the model. Further important product characteristics are: Excellent read algorithms based on the SIMATIC MV440 and VS130- code reading systems and many years of experience in industrial applications. No special knowledge required for reliable parameterization of reading features. Parameterization usually unnecessary, and is only required for difficult to read codes. "Setup" is performed automatically by presenting a readable code pattern. Code quality evaluation: displays the key quality parameters of the code to be read. Customized user interface can be easily generated with SIMATIC WinCC flexible/wincc. Web-based user interface; can run on a variety of platforms meeting the following requirements: Internet browser (IE 6.0 or higher), JAVA-VM (MS, SUN). Password protected user interface with integrated access rights administration. Web-based user interface available for easy integration with an HMI device. The browser and JAVA VM requirements previously mentioned also apply in this case. 6 language versions (operator interface, manual and online help are each available in German, English, French, Spanish, Italian, and Chinese). In addition, SIMATIC MV40 SR-P offers the following highlights: Autotrigger mode: Automatic detection of a code without an external trigger signal - Saving of sensor technology and cabling - Reduced potential for error as there are fewer components - Solution for applications where proximity switches and light barriers cannot be used Open web API interface for comfortable creation of customized applications and PC based camera remote control Multicode: reads multiple codes in one step within the same field of view. - ID-Genius: a high-performance code reading algorithm for poorly legible directly marked data matrix codes (DPM: Direct Part Marking) Application Key features of the SIMATIC MV40: Code reading Comparing the read result with a preset value Formatting of read results for further use The range of application for the SIMATIC MV40 product family extends to practically all areas of industrial production. The possibilities for use range from identification of stationary parts to fast moving parts on conveyor systems. The high-performance integrated lighting allows for an extremely compact design. The unit is protected from environmental influences with a degree of protection IP67. The SIMATIC MV40 code readers are therefore suitable for all industrial applications, also for direct marking (Direct Part Marking - DPM). In addition to industrial production, thanks to its small size and flexibility, the SIMATIC MV40 code reader is also ideally suited to the packaging industry (e.g. F&B, pharmaceuticals and tobacco). /858 Siemens IK PI 015

80 SIMATIC Identification systems Code reading systems SIMATIC MV40 Application (continued) Design The MV40 code readers include all common communication SIMATIC MV40 is a particularly compact code reading system. interfaces, such as Ethernet or PROFINET, and can therefore be The device can be assembled from individual components or ordered as a ready-assembled unit. The MV40 is available in two connected to a wide variety of systems. An integrated RS4 interface makes it possible to use all of the RFID communication versions: modules, such those required for the PROFIBUS connection. In this case, the combination of code reader and RFID reader is Basic model: SIMATIC MV40 SR-B also possible on one communication module. Performance model: SIMATIC MV40 SR-P The reading devices are particularly easy to use and commission despite the wide variety of options for use. Parameters are components are available in addition to the basic units (body): For the individually configurable models the following individual automatically configured for most applications. If reconfiguration Lenses is required, however, parameterization can be carried out without the need for pre-installed software via the integrated Web Ring lights server using an Internet browser. The basic units include the protective barrel for the lens. Due to the properties and functions described, the emphasis for The preconfigured models include an integrated lens (6 mm, aperture 5.6) and a red ring light including protective barrel. MV40 is on the following sectors and applications: Automobile industry: The following accessories are available for the connection and - Needle markings on various drive components (DPM), e.g. installation: cylinder heads, cylinder blocks, manifolds. - Laser markings on various power train components (DPM), Flexible mounting angle e.g. camshafts, crankshafts, cylinder piston, connecting Power DIO RS3 cable (M16 connector on open end) rods, gearbox components. M1 Ethernet cable (varying lengths) - Laser markings on electronic components, printed circuit boards, or enclosures. Ethernet cable (M1 to RJ45) for commissioning/lab operation; m in length Pharmaceutical industry, food industry (F&B), tobacco industry: Special communication module cable for M16 connector - Print or laser markings on medicines (DPM, OCR). (M16 to M1) for connecting to RFID communication modules - Recording the contents of cartons (up to 150 codes). (ASM). Can be expanded using standard communication - Read portal by linking several cameras. module cables, if required. Aerospace industry: Plug-in power supply for demonstration and lab operation (for - Needle or laser markings on gas turbine blades (DPM). office environment only) - Needle or laser markings on jet engine components (DPM). CD with installation/operating instructions (supplied with unit) Medical equipment: Further information can be found in the supplied manual. - Laser markings on heart pacemakers and other implants (DPM). - Laser markings on medical devices (DPM). Function Electronics: Key features of the SIMATIC MV40: - Needle or laser markings on hard disk components. Code reading (refer to "Overview" and "Range of application") - Lasered or etched markings on hard disk components (DPM). Formatting of read results for further use and/or comparison Semiconductors: Comparing the read result with a preset value - Laser markings on rigid and flexible circuit boards (DPM). - Specification of a comparison string via one of the serial - Laser markings on enclosed semiconductor components, ports (PROFINET (ASM and onboard), PROFIBUS (ASM), heat sinks or heat exchangers (DPM). RS3) - Comparison of the formatted read results with the More information is available in the accompanying manual. comparison string The functions can be used individually or they can be combined. Siemens IK PI 015 /859

81 SIMATIC Identification systems Code reading systems SIMATIC MV40 Function (continued) The SIMATIC MV40 reads the following codes: 1D codes (barcodes): - Int. /5 (no checksum) - Int. /5+CS (checksum included) - Code 18 - Code 39 (no checksum) - Code 39+CS (checksum included) - EAN 13 -EAN 8 -UPC-A -UPC-E -GS1 Databar 14 - GS1 Databar Stacked - GS1 Databar Limited - GS1 Databar Expanded D codes: -DMC - PDF417 -QR -DotCode - Vericode The SIMATIC MV40 reads the codes found on a wide variety of components and surfaces, including: Paper or plastic labels Plastic parts Circuit boards Metallic objects The SIMATIC MV40 reads codes of a wide variety of marking types, such as: Printed Dot peened Laser Stamped Bored Field of vision height (mm) , Distance cameraobject 109 (mm) 106 VGA mode Format 4:3 Field of vision width (mm) Field of vision height (mm) , Distance cameraobject (mm) WVGA mode Format 16:10 Field of vision width (mm) G_FS10_XX_00393 SIMATIC MV40 field of view dimensions for the 6 mm lens 50.5 Field of vision height (mm) 300 Distance cameraobject (mm) 50.5 Field of vision height (mm) 300 Distance cameraobject (mm) VGA mode WVGA mode Format 4: Format 16: Field of vision width (mm) Field of vision width (mm) G_FS10_XX_0043 SIMATIC MV40 field of view dimensions for the 16 mm lens Further information can be found in the supplied manual. /860 Siemens IK PI 015

82 Integration Various onboard connection options and convenient function blocks are available for the integration into the automation level. In the case of SIMATIC MV40, direct connection via PROFINET, Ethernet or RS3 is possible. SIMATIC Identification systems Code reading systems SIMATIC MV40 In addition, communication modules are available for connection to other bus systems or the shared interface with RFID readers. For further details on the communication modules, see the section "Communication modules". Management level Ethernet Manufacturing Execution Systems (MES) Enterprise Resource Planning (ERP) Industrial Ethernet Control level SIMATIC connection Connection to PC S7-300 S HMI S7-100/ RF10C RFID Middleware PROFINET/ Industrial Ethernet Industrial Ethernet PROFIBUS RS3/ RS4 Field level ASM 456 SCALANCE X108PoE MV440 MV440 RF340R RF180C/ MV440 MV440 RF18C (TCP/IP) RF60R MV40 MV40 MV40 RF640R G_FS10_XX_00356 Integration of the SIMATIC MV40 in the automation environment Technical specifications Article No. 6GF340-0AA0 6GF340-0AA40 Product-type designation MV40 SR-B code reader MV40 SR-P code reader Suitability for installation 1D codes: Int. /5, Code 18, Code 39, EAN 13, EAN 8, UPC-A, UPC-E, GS1, D codes: DMC, PDF417 (without: Truncated, Micro and Macro), QR (without: Micro and Macro), Vericode 1D codes: Int. /5, Code 18, Code 39, EAN 13, EAN 8, UPC-A, UPC-E, GS1, D codes: DMC, PDF417 (without: Truncated, Micro and Macro), QR (without: Micro and Macro), Vericode Interfaces Design of the electrical connection M1, d-coded M1, d-coded the Industrial Ethernet Interface Design of the electrical connection - - of the PROFIBUS interface Design of electrical connection M16, 1-pin M16, 1-pin of RS 4 interface Design of electrical connection M16, 1-pin M16, 1-pin of RS 3 interface Design of electrical connection M16, 1-pin M16, 1-pin for supply voltage Design of electrical connection M16, 1-pin M16, 1-pin at the digital inputs/outputs Number of digital inputs 1 1 Number of digital outputs 3 3 Design of digital inputs One high-speed trigger input One high-speed trigger input Design of digital outputs isolated outputs 50 ma, 1 high-speed trigger input for external lighting isolated outputs 50 ma, 1 high-speed trigger input for external lighting Siemens IK PI 015 /861

83 SIMATIC Identification systems Code reading systems SIMATIC MV40 Technical specifications (continued) Article No. 6GF340-0AA0 6GF340-0AA40 Product-type designation MV40 SR-B code reader MV40 SR-P code reader Optical data Design of image sensor of camera CMOS chip, VGA (640 x 480), WVGA (75 x 480) CMOS chip, VGA (640 x 480), WVGA (75 x 480) Type of image capture Global shutter Global shutter Range mm mm note Adjustable within the range Adjustable within the range Mounting type of lens Fixed (M1) Fixed (M1) Nature of fluorescent material Integrated lighting or external lighting according to accessories list Integrated lighting or external lighting according to accessories list Image acquisition frequency 50 Hz 80 Hz maximum Code reading rate maximum 9 1/s 50 1/s Type of focusing Manual adjustment on the lens cover Manual adjustment on the lens cover Supply voltage, current consumption, power loss Supply voltage for DC rated value 4 V 4 V Supply voltage for DC V V Consumed current At 4 V with DC typical 0.17 A 0.17 A maximum A A Stored energy time supply voltage 0.01 s 0.01 s failure minimum Mechanical data Material Die-cast aluminum Die-cast aluminum Color petrol blue petrol blue Permitted ambient conditions Ambient temperature during operating 0 50 C 0 50 C during storage C C during transport C C Relative humidity at 5 C without condensation during operating maximum 95 % 95 % Protection class IP IP67 IP67 Resistance against shock According to IEC According to IEC Resistance against shock 150 m/s² 150 m/s² Resistance against vibration 10 m/s² 10 m/s² Design, dimensions and weight Width 5.5 mm 5.5 mm Height 70.7 mm 70.7 mm Depth 39.5 mm 39.5 mm Net weight 0.5 kg 0.5 kg Mounting type x M4 screws x M4 screws Product properties, functions, components general Product feature silicon-free Yes Yes Type of display 4 LEDs 4 LEDs Standards, specifications, approvals Verification of suitability CE, KCC, F&B suitable, UL CE, KCC, F&B suitable, UL Accessories Accessories Mounting brackets, built-in ring lamps, M1 lenses Mounting brackets, built-in ring lamps, M1 lenses /86 Siemens IK PI 015

84 SIMATIC Identification systems Code reading systems SIMATIC MV40 Ordering data Article No. Article No. SIMATIC MV40 SR-B 6GF340-0AA0 Cables Pre-configured basic model: Including lens (6 mm, aperture 5.6) and a red ring light, without multicode and ID-Genius algorithm SIMATIC MV40 SR-P Preconfigured performance model Including lens (6 mm, aperture 5.6) and a red ring light, for very fast read rates, with multicode and ID-Genius algorithm SIMATIC MV40 SR-B Basic model body: Does not include multicode or the ID-Genius algorithm SIMATIC MV40 SR-P Performance model body: For very high read rates; includes multicode reading and the ID-Genius algorithm Lens accessories Lens kit 6 mm Lens 6 mm, aperture 5.6, including protective barrel Lens kit 16 mm Lens 16 mm, aperture 4, including protective barrel Protective barrels for lenses Protective barrel replacement set Contains: x protective barrel, 3x O-rings, 8x mounting screws, offset screwdriver Built-in ring lights Built-in ring lamp, red Built-in ring lamp, white Built-in ring lamp, infrared 6GF340-0AA40 6GF340-0AX0 6GF340-0AX40 6GF340-0AC00-0LK0 6GF340-0AC00-1LK0 6GF340-0AC00-AA0 6GF340-0AC00-1LT0 6GF340-0AC00-LT0 6GF340-0AC00-3LT0 IE connecting cable 6XV1871-5TH0 M1-180/IE FC RJ45 plug-145 for commissioning, service and installation Pre-assembled IE FC TP trailing cable GP x (PROFINET type C) with M1 plug (D-coded) and IE FC RJ45 plug, IP65/IP67 degree of protection, length: m IE Connecting Cable M1-180/M1-180 Pre-assembled IE FC TP Trailing Cable GP x (PROFINET Type C) with two 4-pin M1 plugs (D-coded) up to 85 m, IP65/IP67 degree of protection. Lengths: 0.3 m 6XV1870-8AE m 6XV1870-8AE50 1 m 6XV1870-8AH m 6XV1870-8AH15 m 6XV1870-8AH0 3 m 6XV1870-8AH30 5 m 6XV1870-8AH50 10 m 6XV1870-8AN10 15 m 6XV1870-8AN15 Industrial Ethernet 6GK1901-1BB10-AA0 FastConnect plug connector, x, 180 cable outlet RJ45 plug connector (10/100 Mbit/s) with rugged metal enclosure and FastConnect technology, for Industrial Ethernet FastConnect cable x. For further cables, see under "Passive network components". Cable 4 V power supply Power cable, M16 pre-assembled, push-pull. Various lengths: 1.5 m 6GF3400-0BH15 m 6GF3400-1BH0 Power supply cable DIO-RS3 Power IO RS3 cable, M16 assembled on one end, open on other end Various lengths: 10 m 6GF3440-8BA 30 m 6GF3440-8BA4 Adapter cable for RFID communication modules (ASM): 6GF340-0AC00-CB0 M16 connector (MV40) to M1 connector (communication module); length: m; expandable to any length with standard communication module cables. Cable for communication module interface Standard communication module cable for installation, pre-assembled connecting cable for ASM 456, RF160C, RF170C, RF180C, and RF18C. Various lengths: m 6GT891-4FH0 5 m 6GT891-4FH50 10 m 6GT891-4FN10 0 m 6GT891-4FN0 50 m 6GT891-4FN50 Siemens IK PI 015 /863

85 SIMATIC Identification systems Code reading systems SIMATIC MV40 Ordering data Article No. Article No. Supports Additional accessories Mounting bracket for SIMATIC MV40 6GF340-0AC00-1AA0 SCALANCE X04- Industrial Ethernet Switch Industrial Ethernet switches with integral SNMP access, Web diagnostics, copper cable diagnostics, and PROFINET diagnostics for configuring line, star and ring topologies; with integrated redundancy manager (Exception: SCALANCE X08PRO); including operating instructions, Industrial Ethernet network manual and configuration software on CD-ROM. With electrical and optical ports for glass multimode FOC up to max. 5 km: Four 10/100 Mbit/s RJ45 ports and two fiber-optic cable ports 6GK504-BB10-AA3 Plug-in power supply (EU, US) 6GF340-0AC00-1PS0 For demo and lab operation (for office environment only) /864 Siemens IK PI 015

86 SIMATIC Identification systems Code reading systems SIMATIC MV440 Overview Benefits SIMATIC MV440 with built-in ring light and D65 protective barrel and with external ring light and D65 protective barrel The SIMATIC MV440 readers have been specially developed for use in industrial production. The devices offer professional decoding algorithms for machine-readable codes and text recognition in one device for production and logistics. The SIMATIC MV440 device family is characterized by flexibility, reliability and ease of use. The list of readable codes includes all common matrix and barcodes which, regardless of the printing technology and the carrier medium used, are recognized reliably. A special feature of this device is its ability to read data matrix code (DMC) which is frequently used, especially in production, for direct part marking (DPM) and places the highest demands on the readers. The operating range of the devices extends from close range 70 mm to distant range 3000 mm. Due to the freely selectable lenses and lighting, the working range as well as implementation in applications with special requirements is almost unrestricted. Integration in industrial automation environments is via standardized fieldbus technology, but open interfaces are also supported. Highlights at a glance: Compact design with IP67 degree of protection. Very high reading reliability and read rates thanks to Siemens decoding algorithms. Different screen resolutions can be selected specific to the application. Flexible adaptation to the application by means of freely selectable lenses and lighting. Option of integrated or external high-performance lighting Variety of interfaces: Ethernet (PoE), PROFINET (PoE), RS3, DI/DO, communication module interface. Wide range of connector technology can be used by means of communication modules. Function block for PROFINET/PROFIBUS can be used with SIMATIC and SIMOTION. Web-based user interface can be used for parameter assignment and monitoring, without the need for installation. Further important product characteristics are: No special knowledge required for reliable parameterization of reading features. Automatic "setup" by presenting a readable code pattern. Autotrigger mode: automatic detection of a code without an external trigger signal - Savings in sensor technology and cabling. - Reduced potential for error as there are fewer components. - Solution for applications in which proximity switches and light barriers cannot be used. Multicode: Reads multiple codes in one step within the same field of view. ID-Genius: a high-performance code reading algorithm for poorly legible directly marked data matrix codes (DPM: Direct Part Marking). Code quality evaluation: Displays the key quality parameters of the code to be read. Customized user interface can be generated with SIMATIC WinCC flexible/wincc. Open web API interface for comfortable creation of customized applications and PC based camera remote control Web-based user interface; can run on a variety of platforms meeting the following requirements: Internet browser (IE 6.0 or higher), JAVA-VM (MS, SUN). Extensive diagnostics functions ensure operation at the maximum read rate. User/password-protected operator interface with integrated management of access rights. 6 language versions (operator interface, manual and online help are each available in English, German, French, Spanish, Italian and Chinese). Siemens IK PI 015 /865

87 SIMATIC Identification systems Code reading systems SIMATIC MV440 Application Design The main functions of SIMATIC MV440 are: Reading 1D and D codes. Optical character recognition (OCR). Object detection. Verification (measuring the code quality). Comparing the read result with a preset value. Formatting of read results for further use. The application range of the SIMATIC MV440 product family covers all sectors and areas of industrial production and logistics. The possible applications include the identification of stationary parts through to extremely fast moving parts on a conveyor belt. The powerful integrated lighting allows a very compact design. The device has IP67 degree of protection and is therefore equipped for harsh industrial environments. Due to its particularly powerful lighting, lenses and sensor technology, MV440 specializes in direct part marking (DPM) applications. Due to the high picture quality, MV440 recommends itself for measuring the marking quality (verification) in the area of DPM. Due to the properties and functions described, the emphasis for MV440 is on the following sectors and applications: Automobile industry: - Needle markings on various drive components (DPM), e.g. cylinder heads, cylinder blocks, manifolds. - Laser markings on various power train components (DPM), e.g. camshafts, crankshafts, cylinder piston, connecting rods, gearbox components. - Laser markings on electronic components, printed circuit boards, or enclosures. Pharmaceutical industry, food industry (F&B), tobacco industry: - Print or laser markings on medicines (DPM, OCR). - Recording the contents of cartons (up to 150 codes). - Read portal by linking several cameras. Aerospace industry: - Needle or laser markings on gas turbine blades (DPM). - Needle or laser markings on jet engine components (DPM). Medical equipment: - Laser markings on heart pacemakers and other implants (DPM). - Laser markings on medical devices (DPM). Electronics: - Needle or laser markings on hard disk components. - Lasered or etched markings on hard disk components (DPM). Semiconductors: - Laser markings on rigid and flexible circuit boards (DPM). - Laser markings on enclosed semiconductor components, heat sinks or heat exchangers (DPM). Further information can be found in the supplied manual. SIMATIC MV440 is a compact, stationary code reading system. It consists of one basic unit, which can be configured with other individual components (lens, ring light and protective barrel). This allows the MV440 to be optimally adapted to the application conditions. The SIMATIC MV440 basic unit is available in three versions that differ only with regard to the resolution of the CCD sensor and the associated recording speed mode and read rate. All three versions of the basic unit have identical functionality: SIMATIC MV440 SR 640 pixels x 480 pixels, 50 full screens/s SIMATIC MV440 HR 104 pixels x 768 pixels, 0 full screens/s SIMATIC MV440 UR 1600 pixels x 100 pixels, 15 full screens/s Using the following accessories, the SIMATIC MV440 basic units can be tailored to the requirements of the application. For a detailed listing of the individual accessories, please refer to the section entitled "Accessories": Lenses Protective barrel for lens Ring lights The following accessories are available for the connection and installation: Flexible mounting plate Power DIO RS3 cable (M16 connector on open end) M1 Ethernet cable (varying lengths) Ethernet cable (M1 to RJ45) for commissioning/lab operation; m in length Special communication module cable for M16 connector (M16 to M1) for connecting to RFID communication modules (ASM). Can be expanded using standard communication module cables if required. Plug-in power supply for demonstration and lab operation (for office environment only) CD with installation/operating instructions (supplied with unit) /866 Siemens IK PI 015

88 SIMATIC Identification systems Code reading systems SIMATIC MV440 Design (continued) The following configurations are recommended for the close or distant ranges: Configuration for close range Lenses Ring lights Protective barrel for lens Mini lens 8.5 mm The built-in ring light cannot be used (alternative: external mounting of a D65 protective barrels for lenses can be used. ring light). Mini lens 6 mm Built-in ring lights can be used. Mini lens 1 mm Mini lens 16 mm Mini lens 5 mm Mini lens 35 mm Mini lens 50 mm Mini lens 75 mm Use of the protective barrel extender required (on request). Configuration for distant range Lenses Ring lights Protective barrel for lens Mini lens 6 mm External ring lights can be used. D65 protective barrels for lenses Mini lens 8.5 mm Mini lens 1 mm Mini lens 16 mm Mini lens 5 mm Mini lens 35 mm Mini lens 50 mm Mini lens 75 mm can be used. Function The main functions of SIMATIC MV440 are: Reading 1D and D codes Verification (required license "Veri-Genius") Text recognition (required license "Text-Genius") Comparison of the read result with a default value Object recognition (required license "Pat-Genius") Formatting the read result for forwarding The functions can be used individually or they can be combined. Read The SIMATIC MV440 reads the following 1D and D codes (detailed information can be found in the manual): 1D codes (barcodes): - Int. /5 (with/without checksum) - Code 18 - Code 93 - Code 39 (with/without checksum) - Code 3 -EAN 13 -EAN 8 -UPC-A -UPC-E - CodaBar - GS1 DataBar (Omnidirectional, Stacked, Limited, Expanded) - Pharmacode (0 and 180 ) - Postnet D codes: - Data Matrix Code (ECC 0-00) - PDF417 (without: Truncated, Micro and Macro) - QR (without: Micro and Macro) -DotCode - Vericode (demo mode/vericode license) Verification Code verification is the term used for measuring the marking quality of 1D and D codes. This additional functionality is subject to license and is available for every SIMATIC MV440 by installing the "Veri-Genius license". The following verification methods are supported: ISO/IEC TR9158 (previously AIM DPM-1-006) Siemens DPM ISO/IEC AS913 Rev. A (previously IAQG) ISO/IEC (previously ANSI X ) For more detailed information, refer to the chapter "Verification systems". Optical character recognition Text recognition is used to detect plain text (Optical Character Recognition: OCR). This additional functionality is subject to license and is available for every SIMATIC MV440 by installing the "Text-Genius license" or the "Text-Genius-Plus License". Text recognition with the "Text-Genius-Plus license" is able to recognize many fonts without training immediately after installation. Particularly suitable fonts are: OCR-A Semifont M13 and similar fonts With training ("Text-Genius-Plus license"), text recognition is able to recognize just about all fonts even with distortion and other influences resulting in varied representation. By contrast, this version requires training overhead but offers almost unlimited potential in expanding the characters to be recognized. For more detailed information, refer to the chapter "Text recognition". Siemens IK PI 015 /867

89 SIMATIC Identification systems Code reading systems SIMATIC MV440 Function (continued) Object detection Object recognitiong is used for finding and recognizing trained patterns in the picture. This functionality can be used in standalong mode or in combination with all the other named functions, and therefore has different application areas. Shape recognition offers the following functionality: Object recognition (classification) Position detection (position, orientation, scaling) Presence check (object recognition and position check with setpoint specification) Completeness check (multiple presence check with setpoint specification) Text recognition (based on the contour of any character or symbol. However, shape recognition can also be used in combination with text recognition, for example. In this case, the text recognition read area can track the current position of an object or label. Integration Various onboard connection options and convenient function blocks are available for the integration into the automation level. In the case of SIMATIC MV440, for example, direct connection via PROFINET, Ethernet or RS3 is possible. For more detailed information, refer to the chapter "Shape recognition". Note: In demo mode, the full functionality of the devices is available. Testing of a licensed function is therefore possible at any time. However, the output result is unusable, because one or more characters of the result will be randomly replaced by the character '?'. Binary results are completely suppressed. In addition, communication modules are available for connection to other bus systems or the shared interface with RFID readers. Further information can be found in the section "Communication modules". Management level Ethernet Manufacturing Execution Systems (MES) Enterprise Resource Planning (ERP) Industrial Ethernet Control level SIMATIC connection Connection to PC S7-300 S HMI S7-100/ RF10C RFID Middleware PROFINET/ Industrial Ethernet Industrial Ethernet PROFIBUS RS3/ RS4 Field level ASM 456 SCALANCE X108PoE MV440 MV440 RF340R RF180C/ MV440 MV440 RF18C (TCP/IP) RF60R MV40 MV40 MV40 RF640R G_FS10_XX_00356 RFID integration into PROFINET/Ethernet network Configuration tool for SIMATIC MV440 You will find a compact configuration tool here for assembling the SIMATIC MV440. /868 Siemens IK PI 015

90 SIMATIC Identification systems Code reading systems SIMATIC MV440 Technical specifications Article No. 6GF3440-1CD10 6GF3440-1GE10 6GF3440-1LE10 Product-type designation Code reader MV440 SR MV440 HR code reader Code reader MV440 UR Suitability for installation 1D codes: Int. /5, Code 18, Code 93, Code 39, Code 3, EAN 13, EAN 8, UPC-A, UPC-E, GS1, Pharmacode, Postnet, D codes: DMC, PDF417 (without: Truncated, Micro and Macro), QR (without: Micro and Macro), Vericode, text recognition: OCR-A, Semifont M13, similar fonts, code verification: AIM DPM-1-006, Siemens DPM, ISO/IEC 15415, AS913 Rev. A, ISO/IEC D codes: Int. /5, Code 18, Code 93, Code 39, Code 3, EAN 13, EAN 8, UPC-A, UPC-E, GS1, Pharmacode, Postnet, D codes: DMC, PDF417 (without: Truncated, Micro and Macro), QR (without: Micro and Macro), Vericode, text recognition: OCR-A, Semifont M13, similar fonts, code verification: AIM DPM-1-006, Siemens DPM, ISO/IEC 15415, AS913 Rev. A, ISO/IEC D codes: Int. /5, Code 18, Code 93, Code 39, Code 3, EAN 13, EAN 8, UPC-A, UPC-E, GS1, Pharmacode, Postnet, D codes: DMC, PDF417 (without: Truncated, Micro and Macro), QR (without: Micro and Macro), Vericode, text recognition: OCR-A, Semifont M13, similar fonts, code verification: AIM DPM-1-006, Siemens DPM, ISO/IEC 15415, AS913 Rev. A, ISO/IEC Interfaces Design of the electrical connection M1, d-coded, PoE M1, d-coded, PoE M1, d-coded, PoE the Industrial Ethernet Interface Design of the electrical connection of the PROFIBUS interface Design of electrical connection M1, 8-pin M1, 8-pin M1, 8-pin of RS 4 interface Design of electrical connection M16, 1-pin M16, 1-pin M16, 1-pin of RS 3 interface Design of electrical connection M16, 1-pin M16, 1-pin M16, 1-pin for supply voltage Design of electrical connection M16, 1-pin M16, 1-pin M16, 1-pin at the digital inputs/outputs Number of digital inputs Number of digital outputs Design of digital inputs 4 opto isolated inputs (NPN, PNP capability) optionally as output, one high-speed trigger input 4 opto isolated inputs (NPN, PNP capability) optionally as output, one high-speed trigger input 4 opto isolated inputs (NPN, PNP capability) optionally as output, one high-speed trigger input Design of digital outputs 4 isolated outputs optionally as input, short-circuit-proof, max. 50 ma, 1 high-speed trigger input for external lighting 4 isolated outputs optionally as input, short-circuit-proof, max. 50 ma, 1 high-speed trigger input for external lighting 4 isolated outputs optionally as input, short-circuit-proof, max. 50 ma, 1 high-speed trigger input for external lighting Optical data Design of image sensor of camera CCD chip 1/3", 640 x 480 CCD chip 1/3", 104 x 769 CCD chip 1/1.8", 1600 x 100 Type of image capture Global shutter with manual or automatic exposure time Global shutter with manual or automatic exposure time Global shutter with manual or automatic exposure time Range m m m Range note Mounting type of lens Nature of fluorescent material Using C-mount lenses and lens accessories, the range can be exactly matched to the application C mount lens connection with Plexiglas lens protection, 65 mm diameter Integrated lighting or external lighting according to accessories list Using C-mount lenses and lens accessories, the range can be exactly matched to the application C mount lens connection with Plexiglas lens protection, 65 mm diameter Integrated lighting or external lighting according to accessories list Using C-mount lenses and lens accessories, the range can be exactly matched to the application C mount lens connection with Plexiglas lens protection, 65 mm diameter Integrated lighting or external lighting according to accessories list Image acquisition frequency maximum 80 Hz 30 Hz 5 Hz Code reading rate maximum 80 1/s 30 1/s 5 1/s Type of focusing Manual adjustment on the lens Manual adjustment on the lens Manual adjustment on the lens Siemens IK PI 015 /869

91 SIMATIC Identification systems Code reading systems SIMATIC MV440 Technical specifications (continued) Article No. 6GF3440-1CD10 6GF3440-1GE10 6GF3440-1LE10 Product-type designation Code reader MV440 SR MV440 HR code reader Code reader MV440 UR Supply voltage, current consumption, power loss Supply voltage for DC rated value 4 V 4 V 4 V Supply voltage for DC V V V Consumed current At 4 V with DC typical 0.7 A 0.7 A 0.7 A maximum A A A Stored energy time supply voltage 0.01 s 0.01 s 0.01 s failure minimum Mechanical data Material Die-cast aluminum Die-cast aluminum Die-cast aluminum Color petrol blue petrol blue petrol blue Permitted ambient conditions Ambient temperature during operating 0 50 C 0 50 C 0 50 C during storage C C C during transport C C C Relative humidity at 5 C without 95 % 95 % 95 % condensation during operating maximum Protection class IP IP67 IP67 IP67 Resistance against shock According to IEC According to IEC According to IEC Resistance against shock 100 m/s² 100 m/s² 100 m/s² Resistance against vibration 10 m/s² 10 m/s² 10 m/s² Design, dimensions and weight Width 68 mm 68 mm 68 mm Height 1 mm 1 mm 1 mm Depth 45 mm 45 mm 45 mm Net weight 0.55 kg 0.55 kg 0.55 kg Mounting type 4 x M4 screws 4 x M4 screws 4 x M4 screws Product properties, functions, components general Product feature silicon-free Yes Yes Yes Type of display 5 LEDs 5 LEDs 5 LEDs Standards, specifications, approvals Verification of suitability CE, KCC, F&B suitable, UL CE, KCC, F&B suitable, UL CE, KCC, F&B suitable, UL Accessories Accessories Licenses (verification and text recognition), mounting brackets, built-in ring lights, external ring lights, C-mount lenses, protective barrels for lenses Licenses (verification and text recognition), mounting brackets, built-in ring lights, external ring lights, C-mount lenses, protective barrels for lenses Licenses (verification and text recognition), mounting brackets, built-in ring lights, external ring lights, C-mount lenses, protective barrels for lenses /870 Siemens IK PI 015

92 SIMATIC Identification systems Code reading systems SIMATIC MV440 Ordering data Article No. Article No. SIMATIC MV440 SR 6GF3440-1CD10 Optional software modules For one- and two-dimensional codes. Optional: Text recognition (OCR), object detection and verification of barcodes and data matrix codes. Variable image field and distance. Resolution: 640 x 480 pixels. PoE; IP67 using protective barrel for lens and sealing caps, otherwise IP40; package comprises reader, CD and plastic protective barrel for lens. SIMATIC MV440 HR For one- and two-dimensional codes. Optional: Text recognition (OCR), object detection and verification of barcodes and data matrix codes. Variable image field and distance. Resolution: 104 x 768 pixels. PoE; IP67 using protective barrel for lens and sealing caps, otherwise IP40; package comprises reader, CD and plastic protective barrel for lens. SIMATIC MV440 UR For one- and two-dimensional codes. Optional: Text recognition (OCR), object detection and verification of barcodes and data matrix codes. Variable image field and distance. Resolution: 1600 x 100 pixels PoE; IP67 using protective barrel for lens and sealing caps, otherwise IP40; package comprises reader, CD and plastic protective barrel for lens. 6GF3440-1GE10 6GF3440-1LE10 Text recognition module "Text-Genius" License for the module "Text-Genius", supplied on USB flash drive; executable on SIMATIC MV440 firmware V3.0 and higher (MV440 not included in the scope of supply). Description see Catalog ID 10. Text recognition module "Text-Genius Plus" License for the module "Text-Genius Plus", supplied on USB flash drive; executable on SIMATIC MV440 firmware V5.0 and higher (MV440 not included in the scope of supply). Description see Catalog ID 10. Verification module "Veri-Genius" License for the module "Veri-Genius", supplied on USB flash drive; executable on SIMATIC MV440 firmware V4.0 and higher (MV440 not included in the scope of supply). Description see Catalog ID 10. Shape recognition module "Pat-Genius" License for the module "Pat-Genius", supplied on USB flash drive; executable on SIMATIC MV440 firmware V6.0 and higher (MV440 not included in the scope of supply). Description see Catalog ID 10. 6GF3400-0SL01 6GF3400-1SL01 6GF3400-0SL0 6GF3400-0SL03 Siemens IK PI 015 /871

93 SIMATIC Identification systems Code reading systems SIMATIC MV440 Ordering data Article No. Article No. Accessories Protective barrels for lenses Lens accessories Mini lenses with fixed focal length, adjustable aperture and focus (see also "Lenses" section in Catalog ID 10). Protective barrel for lens D65 made of metal, for built-in ring lights, internal diameter 57 mm, max. lens length 57 mm, IP67 degree of protection. Glass front pane Plastic front pane 6GF3440-8AC11 6GF3440-8AC1 Mini lens 6 mm, 1: 1,4 6GF9001-1BB01 D = 3 mm, L = 37.5 mm Mini lens 8.5 mm, 1:1.5 6GF9001-1BE01 D = 4 mm, L = 47 mm, not suitable in combination with built-in ring lights Mini lens 1 mm, 1:1.4 6GF9001-1BL01 D = 9.5 mm, L = 35.7 mm Mini lens 16 mm, 1:1.4 6GF9001-1BF01 D = 9.5 mm, L = 37. mm Mini lens 5 mm, 1:1.4 6GF9001-1BG01 D = 9.5 mm, L = 38.9 mm Mini lens 35 mm, 1:1.6 6GF9001-1BH01 D = 9.5 mm, L = 41.4 mm Mini lens 50 mm, 1:.8 6GF9001-1BJ01 D = 9.5 mm, L = 38 mm Mini lens 75 mm, 1:.8 6GF9001-1BK01 D = 34 mm, L = 63.6 mm, an extension piece is required when using the D65 lens protective barrel (on request) Accessories for utilizing mini lenses at close range Set of intermediate rings 6GF9001-1BU with 0.5 mm, 1.0 mm, 5.0 mm, 10.0 mm, 0.0 mm and 40 mm rings with 31 mm diameter C thread, to be screwed in between the lens and the camera body for image capture in the macro range. Set of intermediate rings 6GF9001-1BU01 with 0.5 mm and x 1.0 mm rings with 31 mm diameter C thread, to be screwed in between the lens and the camera body for image capture in the close range. Protective barrel for lens D65 made of plastic; to achieve IP67 degree of protection; suitable for all variants of MV440 and for use with built-in ring lights; max. internal diameter 55 mm, max. lens length 48 mm. Built-in ring lights Built-in ring light, red Light source: LED red (630 nm) Flash duration 0 µs to 10 ms, range of illumination 800 mm, mounting materials included, IP67 degree of protection when using protective barrel for lens. Built-in white ring light Light source: White LED (440 nm to 650 nm) Flash duration 0 µs to 10 ms, range of illumination 800 mm, mounting materials included, IP67 degree of protection when using protective barrel for lens. Built-in ring light, green Light source: Green LED (500 nm to 570 nm) Flash duration 0 µs to 10 ms, range of illumination 800 mm, mounting materials included, IP67 degree of protection when using protective barrel for lens. 6GF3440-8AC1 6GF3440-8DA11 6GF3440-8DA1 6GF3440-8DA31 Built-in ring lamp, infrared Light source: Infrared LED (850 nm to 880 nm) Flash duration 0 µs to 10 ms, range of illumination 800 mm, mounting materials included, IP67 degree of protection when using protective barrel for lens. 6GF3440-8DA41 /87 Siemens IK PI 015

94 SIMATIC Identification systems Code reading systems SIMATIC MV440 Ordering data Article No. Article No. External ring lights SIMATIC MV400 ring light Ring light, metal, infrared, clear 6GF3400-0LT01-7BA1 light source LED infrared, light source 850 nm, light source 500 mm to mm, suitable for D65 lens protective barrel, supply voltage: 4 V (18 V V), dimensions B x H x T (mm): 14 x 14 x 4.4, degree of protection IP67. Ring light, metal, red, clear 6GF3400-0LT01-8DA1 light source LED infrared, light source 500 mm to mm, suitable for D65 lens protective barrel, supply voltage: 4 V (18 V V) dimensions W x H x D (mm) 14 x 14 x 4.4, degree of protection IP67. Cables IE connecting cable 6XV1871-5TH0 M1-180/IE FC RJ45 plug-145 for commissioning, service and installation Pre-assembled IE FC TP trailing cable GP x (PROFINET type C) with M1 plug (D-coded) and IE FC RJ45 plug, IP65/IP67 degree of protection. Length: m IE M1-180/M1-180 connecting cable Pre-assembled IE FC TP trailing cable GP x (PROFINET type C) with two 4-pin M1 connectors (D-coded) up to max. 85 m, IP65/IP67 degree of protection, RJ45 assembly possible with plug-in connector 6GK1901-1BB10-AA0 (see below). length: 0.3 m 6XV1870-8AE m 6XV1870-8AE50 1 m 6XV1870-8AH m 6XV1870-8AH15 m 6XV1870-8AH0 3 m 6XV1870-8AH30 5 m 6XV1870-8AH50 10 m 6XV1870-8AN10 15 m 6XV1870-8AN15 Cables (continued) Industrial Ethernet 6GK1901-1BB10-AA0 FastConnect plug connector, x, 180 cable outlet RJ45 plug connector (10/100 Mbit/s) with rugged metal enclosure and FastConnect connection method. For Industrial Ethernet FastConnect cable x. For further cables, see under "Passive network components". Cable for communication module interface Communication module cable for connection to communication modules, e.g. ASM 456, RF160C, RF170C, RF180C, and RF18C. Plug-in cable pre-assembled for SIMATIC MV440. Available in the following lengths: m 6GT891-4FH0 5 m 6GT891-4FH50 10 m 6GT891-4FN10 0 m 6GT891-4FN0 50 m 6GT891-4FN50 Cable 4 V power supply Power cable, M16 pre-assembled, push-pull. Various lengths: 1.5 m 6GF3400-0BH15 m 6GF3400-1BH0 Cable power supply DIO RS3 Power IO RS3 cable, M16 preassembled at one end, other end unconnected. Various lengths: Length 10 m 6GF3440-8BA Length 30 m 6GF3440-8BA4 Cable for external ring lights 6GF3440-8BC4 suitable for 6GF3400-0LT0-7DA1, 6GF3400-0LT0-8DA1, M1, open end, 4-pole, not suitable for drag cables, cable connects external ring lights with the control cabinet (4 V, Gnd, strobe), length 10 m. Adapter cable 6GF3440-8BD1 for external ring lights Suitable for 6GF3400-0LT0-7DA1, 6GF3400-0LT0-8DA1 enables direct connection of external ring lights to MV40 and MV440 when using the power supply cable DIO-RS3 (see above) M16, 1-pole socket; M16, 1-pole connector; M1, 4-pole socket, length 5 cm. Siemens IK PI 015 /873

95 SIMATIC Identification systems Code reading systems SIMATIC MV440 Ordering data Article No. Article No. Mounting accessories Further accessories Reader mounting plate Dimensions W x H x D (mm) 80 x 80 x 60, plate thickness: 4 mm 6GF3440-8CA SCALANCE X108PoE Industrial Ethernet Switch Industrial Ethernet Switch for 10/100 Mbit/s, including operating instructions, Industrial Ethernet network manual and configuration software on CD-ROM; 6 x 10/100 Mbit/s RJ45 ports, electrical x 10/100 Mbit/s RJ45 PoE ports, electrical. 6GK5108-0PA00-AA3 Mounting plate for external ring lights Dimensions W x H x D (mm) 96 x 76 x 46, plate thickness: 4 mm. 6GF3440-8CD01 Support system, tri-plate 6GF900-7AD Dimensions W x H x D (mm) 80 x 80 x 60, plate thickness: 4 mm /874 Siemens IK PI 015

96 Overview 3RW44 soft starter with PROFINET communication module The solid-state SIRIUS 3RW44 soft starters are suitable for the torque-controlled soft starting and ramp-down as well as braking of three-phase asynchronous motors. Optionally, SIRIUS 3RW44 soft starters can be upgraded with a PROFIBUS DP or PROFINET module. Thanks to their communication capability and their programmable control inputs and relay outputs the SIRIUS 3RW44 soft starters can be very easily and quickly integrated in higher-level controllers. In addition to soft starting and soft ramp-down, the 3RW44 soft starters provide numerous functions for higher-level requirements. They cover a performance range up to 710 kw (at 400 V) in the inline circuit and up to 1 00 kw (at 400 V) in the insidedelta circuit. The 3RW44 soft starters are characterized by a compact design for space-saving and clearly arranged control cabinet layouts. For optimized motor starting and stopping the innovative SIRIUS 3RW44 soft starters are an attractive alternative with considerable savings potential compared to applications with a frequency converter. The new torque control and adjustable current limiting enable the High-Feature soft starters to be used in nearly every conceivable task. They guarantee the reliable avoidance of sudden torque applications and current peaks during motor starting and stopping. This creates savings potential when calculating the size of the switchgear and when servicing the machinery installed. Be it for inline circuits or inside-delta circuits the SIRIUS 3RW44 soft starter offers savings especially in terms of size and equipment costs. The bypass contacts already integrated in the soft starter bypass the thyristors after a motor ramp-up is detected. This results in a further great reduction in the heat loss occurring during operation of the soft starter at rated value. Combinations of various starting, operating and ramp-down possibilities ensure an optimum adaptation to the applicationspecific requirements. Operation and commissioning can be performed with the user-friendly keypad and a menu-prompted, multi-line graphic display with background lighting. The optimized motor ramp-up and ramp-down can be effected quickly, easily and reliably by means of just a few settings with a previously selected language. Four-key operation and plain-text displays for each menu option guarantee full clarity at every moment of the parameterization and operation. Soft Starters 3RW44 soft starters for High-Feature applications Applicable standards IEC UL/CSA Functionality Equipped with modern, ergonomic user prompting the 3RW44 soft starters can be commissioned quickly and easily using a keypad and a menu-prompted, multi-line graphic display with background lighting. The optimized motor ramp-up and rampdown can be effected quickly, easily and reliably by means of just a few settings with a selectable language. Four-key operation and plain-text displays for each menu option guarantee full clarity at every moment of the parameterization and operation. During operation and when control voltage is applied, the display field continuously presents measured values and operating values as well as warnings and fault messages. An external display and operator module can be connected by means of a connection cable to the soft starter, thus enabling active indications and the like to be read directly from the control cabinet door. The SIRIUS 3RW44 soft starters are equipped with optimum functionality. An integral bypass contact system reduces the power loss of the soft starter during operation. This reliably prevents heating of the switchgear environment. The SIRIUS 3RW44 soft starters have internal device overload protection. This prevents thermal overloading of the power section's thyristors, e.g. due to unacceptably high closing operations. Wiring outlay for installing an additional motor overload relay is no longer needed as the SIRIUS 3RW44 soft starters perform this function too. In addition they offer adjustable trip classes and a thermistor motor protection function. As an option the thyristors can also be protected by SITOR semiconductor fuses from short-circuiting so that the soft starter is still functional after a short circuit (type of coordination ""). And even inrush current peaks are reliably avoided thanks to adjustable current limiting. In addition a creep speed function is available for positioning and setting jobs. With this function the motor can be controlled in both directions of rotation with reduced torque and an adjustable low speed. On the other hand the SIRIUS 3RW44 soft starters offer a new, combined DC braking function for the fast stopping of driving loads. Siemens IK PI 015 /875

97 Soft Starters 3RW44 soft starters for High-Feature applications Overview (continued) Highlights Soft starting with breakaway pulse, torque control or voltage ramp, adjustable torque or current limiting as well as any combination of these, depending on load type Integrated bypass contact system to minimize power loss Various setting options for the starting parameters such as starting torque, starting voltage, ramp-up and ramp-down time, and much more in three separate parameter sets Start-up detection Inside-delta circuit for savings in terms of size and equipment costs Various ramp-down modes selectable: free ramp-down, torque-controlled pump stop, combined DC braking Solid-state motor overload and intrinsic device protection Thermistor motor protection Keypad with a menu-prompted, multi-line graphic display with background lighting Interface for communication with the PC for more accurate setting of the parameters as well as for control and monitoring Simple integration into the motor feeder Simple mounting and commissioning Display of operating states and fault messages Connection to PROFIBUS and PROFINET with optional PROFIBUS DP or PROFINET module External display and operator module Mains voltages from 00 to 690 V, 50 to 60 Hz Can be used up to 60 C (derating from 40 C) Ordering data Version Article No. PROFINET communication module For 3RW44 soft starter integration in the PROFINET network, suitable for devices with firmware version E1 or higher 3RW4900-0NC00 3RW4900-0NC00 More information For more information, refer to Catalog IC 10, Chapter 6 "Switching Devices Soft Starters and Solid-State Switching Devices", Industry Mall or Interactive Catalog CA 01. Soft starters Soft Starter ES software Overview The Soft Starter ES software permits the quick and easy parameterization, monitoring and diagnostics of SIRIUS 3RW44 High-Feature soft starters for service purposes. The device parameters can be configured directly on the PC and transferred to the soft starter through a serial cable or an optional PROFIBUS/PROFINET interface. Easy and clearly arranged parameter setting of the 3RW44 soft starter with Soft Starter ES 007 More information For more information, refer to Chapter 3 "PROFIBUS", Catalog IC 10, Chapter 14 "Parameterization, Configuration and Visualization with SIRIUS", Industry Mall or Interactive Catalog CA 01. /876 Siemens IK PI 015

98 Motor starters for use in the field, high degree of protection M00D motor starters for PROFINET Overview The intelligent, highly flexible M00D PROFIBUS/PROFINET motor starters are the most functional motor starters of the SIRIUS motor starter family in the high degree of protection IP65 for PROFIBUS/PROFINET communication. They start and protect motors and loads up to 5.5 kw. Direct-online and reversing starter variants are available in a mechanical version and also an electronic version (the latter with soft start function). The particularly robust M00D PROFIBUS/PROFINET motor starters are characterized by numerous functions which can be flexibly parameterized. Their modular design comprises a motor starter module and a communication module. The M00D PROFINET motor starters enable TIA-integrated parameterization through PROFINET from STEP 7 in familiar, user-friendly manner with the same look-and-feel as PROFIBUS. Functionality Basic functionality see Chapter 4 "AS-Interface" "M00D Motor Starters" "General Data" "Overview" Electronic version also with soft start function Robust and widely used M1 connection method for the digital inputs and outputs and the PROFIBUS/PROFINET bus connection All four digital inputs and two digital outputs also exist in the cyclic process image. This provides complete transparency of the process on the control level Full TIA integration: All digital inputs and outputs exist in the cyclic process image and are visible through the bus, providing maximum flexibility and excellent adaptability to the application Flexible assignment of the digital inputs and outputs with all available assignable input actions Extensive diagnostics concept using LEDs and through the bus with the TIA-compatible mechanisms Expanded diagnostics using data records Complete plant monitoring using statistics data record and current value monitoring by means of data records Parameterization through PROFIBUS/PROFINET bus with the help of data records from the user program Control of the motor starter using a command data record from the user program Removable modular control unit quicker device replacement and therefore lower costs when device outages occur since existing wiring is on the control unit and only one device needs to be replaced Parameterization in STEP 7 HW Config using Motor Starter ES (ordering option for start-up software) Start-up and diagnostics with the help of Motor Starter ES (ordering option for start-up software) Trace function through Motor Starter ES for optimized start-up and tracking of process and device values Only with PROFINET: Just one bus system from the MES level to the devices no routers More stations on the bus and possible configuration of flexible bus structures Automatic re-parameterization in case of device replacement thanks to proximity detection Wireless integration of plant segments in difficult environments using WLAN Easier expansion of the system thanks to a higher number of stations on the bus and elimination of terminating resistors M00D motor starter modules for PROFIBUS/PROFINET (without communication module) M00D communication module for PROFINET Mounting and installation The M00D PROFINET/PROFINET motor starter is comprised of a communication module and a motor starter module. Only the motor starter module has to be replaced therefore when replacing devices. This saves time and money. The communication module remains as an active station on the bus and all other system components continue running. This prevents downtimes. The integrated plug-in technology enables far lower wiring outlay: Connecting cables can be plugged directly onto the motor starter module. The PROFINET bus is connected costeffectively using an M1 connection on the device. All versions have identical enclosure dimensions for easier system design and conversion. Siemens IK PI 015 /877

99 Motor starters for use in the field, high degree of protection M00D motor starters for PROFINET Overview (continued) Parameterization and configuration All motor protection functions, limit values and reactions can be defined by parameterization. The user has several user-friendly options for the parameterization. In addition to parameterization directly from STEP 7, which also permits automatic re-parameterization in case of device replacement, it is possible to use the user-friendly Motor Starter ES start-up software. By connecting a programming device directly to PROFIBUS/PROFINET and the Motor Starter ES start-up software, the devices can also be conveniently programmed from a central point through the bus. Also, parameters can be changed during operation from the user program using the data record mechanism so that the function of the motor starter is adapted to the process when required. With the help of a PC and the Motor Starter ES software it is also possible to perform the parameterization through the local point-to-point interface on-site. Functions can be flexibly assigned to the digital inputs and outputs, adapting them to all possible conveyor applications. All digital inputs and outputs exist in the cyclic process image. All limit values for monitoring functions and their reactions are parameterizable and therefore adaptable to the application. Consistency with other products of the SIRIUS M00D motor starter range and with the frequency converter and ET 00pro I/O system is assured. Only with the M00D PROFINET motor starter Thanks to the integrated proximity detection, the device name does not need to be issued manually when a device is replaced. The name is issued automatically by the neighboring devices which note the "names" of the devices in their proximity. No additional start-up measures are required therefore when replacing a device. The new motor starter generation is characterized by high functionality, maximum flexibility and the highest level of automation. The PROFINET is recommended in particular for expansive and highly automated system components because the possibility of monitoring devices and systems with data records (statistical data, measured values and device diagnostics) guarantees an in-depth view of the plant from the control room and therefore increases plant availability. Operation The motor starters record the actual current flow. Evaluating the current of the parameterizable solid-state overload protection increases the availability of the drives, as do reliable signals concerning the overshooting or undershooting of setpoint values. Diagnostics and maintenance Diagnostics is provided through numerous mechanisms and can be used as the customer prefers. The motor starter is TIA-diagnostics compatible, which means that when a fault is identified, a diagnostics alarm is distributed, which invokes the diagnostics-ob with a SIMATIC control. The fault can be evaluated as usual in the user program. The M00D motor starter offers a large variety of diagnostics data through data records. Its functionality is without equal on the market. There are extensive options for reading out data from the motor starter for monitoring devices, systems or processes. The motor starter is equipped internally with 3 logbooks for device faults, motor starter trips and events, which are issued with a time stamp. These logbooks can be read out of the motor starter at any time in the form of data records and provide the plant operator with plenty of information about the state of his plant and process which he can use to carry out improvements. With the slave pointer and statistical data functions it is possible to read out, for example, the maximum internal current values or the number of motor starter connection operations for plant monitoring purposes. This allows deviations in the process to be monitored, but also optimum initial commissioning to take place. The user can draw conclusions about the actual load conditions of the devices in his process and on this basis can optimize his plant maintenance intervals. The device diagnostics data record contains details of all the states of the motor starter, the device configuration and the communication status as a basis for central device and plant monitoring. With installation and maintenance functions (I&M), information (I&M) on modules employed is stored in the motor starter on the one hand, and on the other, data (I&M), which can be specified by the user during configuration, such as location designations. I&M functions serve for troubleshooting faults and localizing changes in hardware at a plant or checking the system configuration. Reordering a device is particularly easy as the result. The integrated maintenance timer can be used to implement preventative maintenance and avoid plant downtimes through look-ahead servicing. Another new feature is the integrated TRACE function with the Motor Starter ES software. It can be used to record measured values as a function of time following a trigger event. This enables process flows to be recorded and their timing optimized. Local control of a drive is possible using the ordering option with integrated manual operation. This is yet another new development which distinguishes the M00D PROFIBUS/PROFINET motor starter from the rest of the market and adds innovative technology, maximum availability and transparency to the system. /878 Siemens IK PI 015

100 Motor starters for use in the field, high degree of protection M00D motor starters for PROFINET Overview (continued) M00D PROFINET motor starters with PROFIenergy Increasing energy prices, far-reaching ecological problems worldwide and the threat of climate change make it necessary for you to be more conscious about your use of energy. Active and effective energy management is possible with PROFIenergy. PROFIenergy is a manufacturer-independent profile on PROFINET, which can be used by all manufacturers, has been standardized by PNO 1) and supports the switching off of electrical devices during dead time and the measurement of energy flow. Switching off during dead times PROFIenergy supports the targeted switching-off of loads during dead time. These can be planned short breaks of a few minutes (such as lunch breaks), longer periods of dead time (such as nights) or unplanned dead time. Energy is always saved when no power is required. 1) In the PNO (PROFIBUS Nutzerorganisation e. V. - PROFIBUS User Organization), manufacturers and users have come together to agree on the standardized communication technologies PROFIBUS and PROFINET. Measuring and visualizing the energy flow as a basis of energy management The objective of energy management is to optimize the use of energy in a company from the purchasing of energy through to the consumption of energy economically and ecologically. Analyses of energy consumption over time can be used to control energy flows, avoid energy peaks, improve ratings and thus save costs. PROFIenergy enables consumption data to be read off from the devices in a unified form. This is recorded during operation and can be displayed on a control panel, for example, or on higherlevel energy management software packages. This ensures that these measured variables are in a uniform manufacturer-independent form and structure that is available to the user for further processing. These PROFIenergy functions thus provide the basis for active load and energy management during operation. PROFIenergy in the M00D PROFINET motor starter The M00D PROFINET motor starter supports "switching during dead time" and "current measurement values" of the motor current using PROFIenergy. These are called commands, because they trigger a reaction in the M00D motor starter. Siemens IK PI 015 /879

101 Motor starters for use in the field, high degree of protection M00D motor starters for PROFINET Overview (continued) Device functions (firmware features) Slave on the bus Function available -- Function not available SIRIUS M00D PROFIBUS SIRIUS M00D PROFINET Fieldbus PROFIBUS to M1 PROFINET to M1 Adjustable number of stations with CPU 315, CPU with CPU 319 Parameterization DIP switches For address setting and terminating resistor -- Motor Starter ES Through bus, optical interface PROFIBUS/PROFINET data records From STEP 7 / HW Config Diagnostics Acyclic through data records Diagnostic interrupt support Process image Process image Byte PII/ Byte PIQ Data channels Local optical interface (manual local) Through Motor Starter ES local interface Using Motor Starter ES through bus Data records (acyclic) Parameterization Using DS 131 (DS = data record) Diagnostics Device-specific DS 9 Measured values Measured values DS 94 Statistics Statistical data DS 95 Commands Using DS 93 Slave pointer Slave pointer DS 96 Logbook Using Motor Starter ES and data records: Device faults DS 7, tripping operations DS 73, events DS 75 Device identification Using DS 100 I&M data Using DS Using data records 0xAFF0... 0xAFF3 Inputs Number 4 Of which in the process image 4 Input action Parameterizable: flexibly assignable action, see manual Quick stop Parameterizable: latching, non-latching /880 Siemens IK PI 015

102 Motor starters for use in the field, high degree of protection M00D motor starters for PROFINET Overview (continued) Device functions (firmware features) Outputs SIRIUS M00D PROFIBUS Number Of which in the process image Output action Parameterizable: flexibly assignable action, see manual SIRIUS M00D PROFINET Brake output 180 V DC / 30/400 V AC / none Motor protection Overload protection Electronic, wide range 1:10 Short-circuit protection Full motor protection Temperature sensor Parameterizable using Motor Starter ES, data record: PTC or Thermoclick or deactivated Device function Repair switch Lower current limit monitoring Parameterizable Upper current limit monitoring Parameterizable Zero current detection Parameterizable: tripping, warning Blocking current Parameterizable Unbalance Parameterizable Load type Parameterizable: 1 and 3-phase Tripping class Parameterizable using Motor Starter ES, data record: CLASS 5, 10, 15, 0 Protection against voltage failure Parameterizable: activated/deactivated Support for PROFIenergy profile Switching during dead times -- Measured motor current values -- Soft starter control function Soft start function Bypass function Only solid-state version Function available -- Function not available Siemens IK PI 015 /881

103 Motor starters for use in the field, high degree of protection M00D motor starters for PROFINET Communication module, motor starter modules Siemens AG 014 Benefits Ordering data M00D PROFINET motor starters with PROFIenergy Both standards and laws are making environmental protection and energy management increasingly important, as is the desire to cut energy costs in production facilities and thus ensure a sustainable competitive advantage. It is thus an objective within the industry to save energy and actively reduce CO emissions. By the careful use of valuable resources, the manufacturer-independent PROFIenergy profile on PROFINET can make an active contribution to environmental M00D PROFIBUS/PROFINET M00D PROFINET protection. motor starter module motor starter (without communication module) Application Version Article No. The M00D PROFIBUS/PROFINET motor starters are particularly suitable for fully TIA-integrated, highly automated conveyor Communication module 3RK1335-0AS01-0AA0 M00D communication module for PROFINET applications which meet all needs with regard to the monitoring for PROFINET of devices and systems and preventative maintenance. M1 termination 7/8" Adaptability of the motor starter functions and maximum flexibility of the device enable a broad range of applications without any limits. The PROFINET-specific expansions are the best assurance of a future-proof investment. M00D PROFIBUS/PROFINET motor starter modules Electromechanical starters (with integrated contactor) 3RK S41-7 AD 7 Setting range for rated operational current / A Direct-on-line starters/reversing starters Direct-on-line starters 0 Reversing starters 1 Direct-on-line starters with manual local operation Reversing starters with manual local 3 operation Brake actuation Without brake actuation 0 Brake actuation (30/400 V AC) 3 Brake actuation (180 V DC) 5 K L Electronic starters (with thyristors) 3RK S71-7 AD K L Direct-on-line starters/reversing starters Direct-on-line starters 0 Reversing starters 1 Direct-on-line starters with manual local operation Reversing starters with manual local 3 operation Brake actuation Without brake actuation 0 Brake actuation (30/400 V AC) 3 Brake actuation (180 V DC) 5 /88 Siemens IK PI 015

104 Motor starters for use in the field, high degree of protection M00D motor starters for PROFINET Accessories Overview Note: For accessories for all SIRIUS M00D motor starters (irrespective of the communication connection) see Chapter 4 "AS-Interface" "SIRIUS M00D Motor Starters" "Accessories" NSA0_00487a Connection for digital input (IO communication, 5-pole) Connection for digital output (IO communication, 4- or 5-pole) Connection for 4 V supply (infeed) Connection for 4 V supply (loop) Connection with PROFINET (input on the left, loop on the right) Communication connection using PROFINET and digital inputs and outputs Siemens IK PI 015 /883

105 Motor starters for use in the field, high degree of protection M00D motor starters for PROFINET Accessories Overview (continued) Siemens AG 014 Version Motor control with PROFINET 3 M1 plugs, angular Screw fixing, 4-pole screw terminals, max mm, angular, D-coded, 4 male contacts 3RK190-H. 3RK190-N. Further accessories 3 Control cables, assembled at one end M1, screw fixing, angular, 4-pole, D coded, 4 male contacts, 3 m 4 male contacts, 5 m 4 male contacts, 10 m Article No. 3RK190-DA00 3RK190-HB30 3RK190-HB50 3RK190-HC10 3 Control cables, assembled at both ends M1, screw fixing, angular at both ends, 4-pole, D coded, male contacts at both ends 3 m 3RK190-NB30 5 m 3RK190-NB50 10 m 3RK190-NC10 PROFINET IE FC TP standard cable GP x sold by the meter PROFINET IE FC TP trailing cable x sold by the meter PROFINET IE FC TP trailing cable GP x sold by the meter PROFINET IE FC TP torsion cable x sold by the meter PROFINET IE FC TP marine cable, 4-core sold by the meter Power cables 5-core, 5 x 1.5 mm, trailing, sold by the meter, minimum order quantity 0 m, maximum order quantity m 6XV1840-AH10 6XV1840-3AH10 6XV1870-D 6XV1870-F 6XV1840-4AH10 6XV1830-8AH10 Version Connection for 4 V power supply of the M00D PROFIBUS/PROFINET Plugs On M00D, 7/8" for screw fixing, angular, screw terminal, 1.5 mm 1 5 female contacts Article No. 3RK190-3DA00 3RK190-3DA00 5 male contacts 3RK190-3BA00 3RK190-3BA00 3RK190-3G. 3RK190-3N. 1 Supply lines, assembled at one end 7/8" for screw fixing, angular, 1.5 mm 5 female contacts, 3 m 5 female contacts, 5 m 5 female contacts, 10 m 1 Supply lines, assembled at both ends 7/8" for screw fixing, angular at both ends, 5-pole pin/socket, 1.5 mm 3RK190-3GB30 3RK190-3GB50 3RK190-3GC10 3 m 3RK190-3NB30 5 m 3RK190-3NB50 10 m 3RK190-3NC10 7/8" sealing caps 1 pack = 10 units 6ES7194-3JA00-0AA0 6ES7194-3JA00-0AA0 /884 Siemens IK PI 015

106 Motor starters for use in the field, high degree of protection Software Motor Starter ES Overview Motor Starter ES for parameterization, monitoring, diagnostics and testing of motor starters More information For more information, refer to Chapter 3 "PROFIBUS", Catalog IC 10, Chapter 14 "Parameterization, Configuration and Visualization with SIRIUS", Industry Mall or Interactive Catalog CA 01. Motor Starter ES is used for start-up, parameterization, diagnostics, documentation and the preventative maintenance of the motor starters in the SIMATIC ET 00S, ET 00pro, ECOFAST and M00D product families. Interfacing is performed Through the local interface on the device With PROFIBUS DP V1 capable motor starters from any point in PROFIBUS or in PROFINET (applies to ET 00S DP V1/ET 00pro/ECOFAST/M00D) With PROFINET-capable motor starters from any point in PROFINET or in PROFIBUS (applies to ET 00S DP V1, ET 00pro/M00D) Using Motor Starter ES, the communication-capable motor starters are easily parameterized during start-up, monitored during normal operation and successfully diagnosed for service purposes. Preventative maintenance is supported by a function for reading out diverse statistical data (e. g. operating hours, operating cycles, cut-off currents, etc.). The user is supported during these procedures with comprehensive Help functions and plain text displays. Motor Starter ES can either be used as a stand-alone program or it can be integrated into STEP 7 via an Object Manager. SIRIUS motor starter block library for SIMATIC PCS 7 Overview With the SIRIUS motor starter PCS 7 block library, SIRIUS ET 00S and ET 00pro motor starters can be easily and simply integrated into the SIMATIC PCS 7 process control system. The SIRIUS motor starter PCS 7 block library contains the diagnostics and driver blocks corresponding to the SIMATIC PCS 7 diagnostics and driver concept as well as the elements (symbols and faceplates) required for operator control and process monitoring. Faceplate of the motor block More information For more information, refer to Chapter 3 "PROFIBUS", Catalog IC 10, Chapter 14 "Parameterization, Configuration and Visualization with SIRIUS", Industry Mall or Interactive Catalog CA 01. Siemens IK PI 015 /885

107 SITOP DC UPS 4 V DC uninterruptible power supplies SITOP UPS1600 Overview By combining one DC UPS module SITOP UPS1600 with at least one UPS1100 battery module and a SITOP power supply unit, longer power failures can be bridged without any interruption. The intelligent battery management automatically detects the UPS1100 energy storage unit, ensures optimized temperaturespecific charging and continuous monitoring. The compact DC UPS modules have overload capability, for example, to supply the inrush current of industrial PCs. In stand-alone mode, they support starting from the battery. The DC UPS communicates openly over a USB or Ethernet/ PROFINET port. It is easily integrated into the PC or PLC environment over the two Ethernet/PROFINET ports. Total integration in TIA provides user-friendly engineering in the TIA Portal and is supported with ready-to-use function blocks for S7 user programs and WinCC faceplates for fast visualization. SITOP UPS Manager supports easy monitoring and configuration in PC systems, e.g. shutdown of several PCs in accordance with the master-slave principle. The integrated web server supports remote monitoring of the DC UPS. Benefits 4 V buffering for a few hours for the purpose of continuing processes Open communication over USB or two Ethernet/PROFINET ports High-performance DC UPS modules in space-saving, slim design High overload capability for mains and buffering operation Starting from the battery module supports stand-alone mode, e.g. for starting generators Easy configuration thanks to automatic detection of battery modules High reliability and availability due to monitoring of the operational readiness, battery feeder, aging and charging status Battery protecting charging due to temperature-specific charging characteristic Defined shutdown of several PCs or controllers on one UPS (versions with Ethernet/PROFINET) Remote monitoring via integrated web server (versions with Ethernet/PROFINET) Time-saving engineering in PC-based systems via SITOP UPS Manager (versions with USB or Ethernet/PROFINET) Full integration in TIA saves time and costs during the planning stage and in operation (versions with Ethernet/ PROFINET) User-friendly engineering in the TIA Portal SIMATIC S7 function blocks for easy integration in STEP 7 user programs Fast integration in operator control and monitoring with WinCC faceplates Application The battery modules that can be connected in parallel bridge power failures for a few hours. This supports the continued operation of processes or parts of them. The function "Starting from the battery" means that the UPS1600 can also be used in stand-alone mode without connection to the supply. Depending on the communication requirements between the DC UPS and the automation components to be protected against power failure, the version of UPS1600 can be selected accordingly. /886 Siemens IK PI 015

108 SITOP DC UPS 4 V DC uninterruptible power supplies SITOP UPS1600 Application (continued) Buffering of simple automation applications In simple applications with mini PLCs (e.g. obstruction lights, stand-alone hydro-electric plants), 4 V buffering is performed by the UPS1600 without a communications interface. The status messages are transferred to the PLC via the digital outputs (isolated). Buffering of applications with networked (Industrial Ethernet) automation computers The UPS1600 with Industrial Ethernet interface protects complex PC-based applications from power failure. Configuration and monitoring is performed using the PC software SITOP UPS Manager. It also supports defined shutdown of several PCs in accordance with the master-slave principle. Controlling LOGO! SIMATIC S7-100 Control Industrial PC Controlling, configurating, monitoring Industrial PC PC 5 4 V DC Industrial Ethernet Power supply SITOP PM107 SITOP UPS1600 Energy Storage Link Uninterruptible 4 V power supply SITOP UPS1100 Buffering of applications with automation computer The UPS1600 with a USB interface is used to buffer automation solutions that are controlled by an industrial PC. All operating and configuring data is communicated over the PC interface. Controlling, configurating, monitoring Industrial PC G_KT01_XX_0080 Power supply SITOP SITOP UPS1600 Energy Storage Link SITOP UPS1100 Uninterruptible 4 V power supply 4 V DC Buffering of applications with networked (PROFINET) automation components For buffering sensitive plant components (e.g. a pumping station with telecontrol) or complete controller solutions (e.g. machine tools) that are integrated into a networked automation solution, the UPS1600 with PROFINET is the perfect choice. Total integration in TIA offers unique advantages for engineering and operation (e.g. diagnostics or visualization). For example, in buffer mode, several controllers can be brought to a defined independently of each other. G_KT01_XX_00796 Power supply SITOP USB SITOP UPS1600 Energy Storage Link Uninterruptible 4 V power supply SITOP UPS V DC Communication over Ethernet/PROFINET offers the most comprehensive possibilities for diagnostics and system integration. The UPS1600 can be directly integrated into the LAN infrastructure over its two ports. G_KT01_XX_00803 Control SIMATIC S7-300/400/ 100/1500, STEP 7 Power supply SITOP Human Machine Interface Panel PC/ PC SIMATIC HMI, WinCC SITOP UPS1600 PC WinCC, SCADA system SITOP UPS1100 Uninterruptible 4 V power supply Engineering PG/ PC, TIA Portal, Step 7 PROFINET Energy Storage Link 4 V DC G_KT01_XX_00797 Siemens IK PI 015 /887

109 SITOP DC UPS 4 V DC uninterruptible power supplies SITOP UPS1600 Design Compact DC UPS modules UPS V/10 A, 0 A with digital inputs and outputs, optionally with USB interface or two Ethernet/PROFINET ports UPS1100 battery modules 1. Ah, 3. Ah, 7 Ah with lead rechargeable batteries of corrosion-resistant lead-calcium high-performance grid plates and glass fiber Function SITOP UPS1600 web server The SITOP UPS1600 with Ethernet/PROFINET has an integrated web server that supports remote monitoring of the uninterruptible power supply. Remote monitoring of Hardware configuration data Operating data of the UPS1600 basic unit and the connected UPS1100 battery module Alarm messages Remote access via Firefox or Internet Explorer 9 (IE 8 with charging of SVG player) IP address Password SITOP UPS1600 software Software tools support convenient integration of the SITOP UPS1600 in both PC-based and PLC-based systems. They make configuring and visualizing the DC UPS easier and the user benefits from the high performance of the SITOP UPS1600. Software for open, PC-based automation systems SITOP UPS Manager Configuration and monitoring is performed easily using the free PC software SITOP UPS Manager. It enables the reactions of the PC to the operating states of the DC UPS to be freely selected and offers comprehensive diagnostic options: Configuration - Connection via USB or Ethernet - All the relevant parameters can be configured in UPS Manager and transferred to the UPS Configuration of "non-coded" rechargeable batteries is possible - The reactions of the PC to the operating states of the UPS can be freely selected, e.g. termination of software applications - Support for reliable downloading of several PCs according to the master-slave principle - The configurations can be saved locally - Integrated OPC server (available soon) - Updating of the UPS1600 firmware is possible - Executable on Windows XP, Windows 7 and Windows 8 operating systems Monitoring - Readout and display of alarms, statuses and operating variables of the UPS1600 and the connected energy storage unit - Tracing of history in trend diagrams Monitor window for battery status in SITOP UPS Manager The password-protected web server supports viewing of the configuring and operating data. Trend diagram for load current in SITOP UPS Manager /888 Siemens IK PI 015

110 SITOP DC UPS 4 V DC uninterruptible power supplies SITOP UPS1600 Function (continued) Software for TIA-based automation systems For convenient integration of the DC UPS in the TIA environment, different software modules are available. Engineering is simple via the TIA Portal. The data for UPS1600 is stored in the hardware catalog version V14 and higher. Special function blocks for SIMATIC S7-300, S7-400, S7-100 and S also support integration in the STEP 7 user program. The comprehensive diagnostics data of the UPS1600 power supply can be visualized using prepared UPS faceplates for WinCC. TIA Portal Convenient and fail-safe integration of SITOP UPS1600 in the PROFINET network by means of drag-and-drop Convenient configuration of SITOP UPS1600 basic units with Ethernet/PROFINET and the UPS1100 battery module simply by selecting from the TIA Portal hardware catalog Free download of HSP (Hardware Support Package) for TIA Portal version V1 SP1 available at Free download of GSD file (generic station description) for STEP 7 V 5.5 available from STEP 7 function blocks Function blocks are available for STEP 7 user programs on SIMATIC S7-300/400/100/1500. They allow further processing of the DC UPS operating data. Free download at: Faceplates for WinCC Ready-to-use faceplates save programming time for visualization of the uninterruptible power supply. The faceplates show all relevant statuses and values of the DC UPS. They are available for the following systems: WinCC V7. + STEP 7 Professional 010 WinCC flexible 008 SP3 + STEP 7 Professional 010 WinCC Comfort/Advanced/ Professional V11 SP + STEP 7 Professional V11 SP WinCC V1 + STEP 7 V1 Free download at: The pre-compiled WinCC faceplates show all the relevant UPS data in a clearly comprehensible display. An icon with color coding for the operating status is also available Establishing the PROFINET connection between the SITOP UPS1600 and the controller is easy and fail-safe in the TIA Portal Siemens IK PI 015 /889

111 SITOP DC UPS 4 V DC uninterruptible power supplies SITOP UPS1600 Technical specifications The table shows the maximum buffering times for the SITOP UPS1100 battery modules for different load currents: The SITOP Selection Tool offers detailed selection guidance according to criteria such as the required backup time, nominal current, peak current and battery connection threshold: SITOP UPS V, 1. Ah (6EP4131-0GB00-0AY0) Buffer times UPS V, 3. Ah (6EP4133-0GB00-0AY0) Load current 1 A 34.5 min.6 h 5.4 h A 15.5 min 1 h.6 h 3 A 9 min 39.3 min 1.6 h 4 A 6.5 min 7.1 min 1. h 6 A 3.5 min 17.5 min 41 min 8 A min 1.1 min 8.6 min 10 A 1 min 9 min 1.8 min 1 A - 7 min 17.3 min 14 A - 5 min 15.1 min 16 A - 4 min 1.5 min 0 A - 1 min 9.1 min UPS V, 7 Ah (6EP4134-0GB00-0AY0) Important information for selecting the battery capacity: Determination of the mains buffering times is based on the discharge period of new or non-aged, completely charged battery modules at a battery temperature not below +5 C to the shutdown of the DC UPS. Battery aging reduces the still available battery capacity up until the end of the service life to typically around 50% of the original capacity value when new (1. Ah/3. Ah/7 Ah, etc.) and the internal resistance increases. When the message "Battery charge > 85%" appears, only around 50% x 85% = approx. 43% of the originally available capacity can be assumed at the end of the battery service life. At battery temperatures below +5 C, the available capacity drops approximately by another 30% at +5 C battery temperature, to approximately 70% of the approximately remaining 43%. There is then only around 30% of the original capacity available. A significantly larger battery capacity must therefore be selected when configuring the plant: A drop to approx. 50% is compensated for by selecting 1 / approx. 0.5 = approx. double the battery capacity (required as per the table for the relevant load current and the relevant buffering time). Available capacity of approx. 43% is compensated for by selecting 1 / approx = approx..33 times the battery capacity. Available capacity of approx. 30% is compensated for by selecting 1 / approx. 0.3 = approx times the battery capacity. Recommendation: Instead of installing double the battery capacity, regular battery replacement halfway through the expected service life (reduction of capacity to approx. 50%) can be more advisable for the following reasons: Capacity does not drop below 100% until the halfway point of the expected battery life (or slightly beyond). With regular replacement after this point, only the single battery capacity (instead of double capacity) must be installed due to aging (-> neutral in price with regard to battery module costs, but only requires half the space). Replacing the battery after half its service life dispenses above all with the large scatter range of the residual capacity at the end of the service life, which is not accurately defined by battery manufacturers (after the full time, many batteries are above, but many are also below the average 50% residual capacity, that is to say, even if double the capacity is installed, the influence of aging at the end of service life is not reliably compensated for, rather only typically) -> When replacing after half the expected service life, the configured buffering time is maintained with considerably greater reliability. In the case of batteries stored in cool conditions (not above +5 C) and for not longer than approximately 4 months, the following service life can be assumed, strongly dependent on battery temperature: Battery temperature Drop to approx. 50% of residual capacity Recommendation: Replace (at 100% of residual capacity) all Alternative recommendation +0 C 4 years years +30 C years 1year +40 C 1 year 0.5 years Install double capacity and replace (1 x per year) In normal cases (installation in the coolest location in the control cabinet at approx. +30 C), the battery should be replaced with single installed battery capacity in accordance with the selection table after 1 year of operation! After a power failure, the battery module is disconnected from the loads at the end of the selected buffering time either automatically or electronically by opening the On/Off control circuit, and as soon as the 4 V input voltage is available again, it is quickly re-charged with the charge current of the relevant DC UPS module (with I-U charge characteristic: First constant current I for fast charging, and changeover to constant voltage U to maintain the charge when the battery is almost full). /890 Siemens IK PI 015

112 SITOP DC UPS 4 V DC uninterruptible power supplies SITOP UPS1600 Technical specifications (continued) DC UPS modules SITOP UPS V/ 10 A SITOP UPS V/ 0 A Article No. 6EP4134-3AB00-0AY0 6EP4134-3AB00-1AY0 (with USB interface) 6EP4134-3AB00-AY0 (with Ethernet/ PROFINET interfaces) 6EP4136-3AB00-0AY0 6EP4136-3AB00-1AY0 (with USB interface) 6EP4136-3AB00-AY0 (with Ethernet/ PROFINET interfaces) Input data Input voltage V in rated / range 1) 4 V DC/ V 4 V DC/ V Connection threshold for buffering.5 V DC ± 3% (factory setting), adjustable: 1 V, 1.5 V, V,.5 V, 3 V, 4 V, 5 V DC or via software..5 V DC ± 3% (factory setting), adjustable: 1 V, 1.5 V, V,.5 V, 3 V, 4 V, 5 V DC or via software. Input current I out rated Approx. 14 A for max. charging current (3 A) Approx. 5 A for max. charging current (4 A) Mains buffering Adjustable range using rotary coding switch Behavior on restoration of input voltage after buffering time On/off control circuit (via external isolated NO contact) Starting from battery with input voltage missing (over external isolated NO contact) Energy storage units Connectable batteries 0.5 min, 1 min, min, 5 min, 10 min, 0 min, max. buffering time or via software Interruption of U out for 5 s for the automatic restart of PCs or optionally no interruption by opening the circuit the buffer mode is terminated by closing the circuit the buffer mode is started coded Siemens types SITOP UPS1100 (max. 6 via Energy Storage Link) non-coded Siemens types 6EP1935-6M... other manufacturers 0.5 min, 1 min, min, 5 min, 10 min, 0 min, max. buffering time or via software Interruption of U out for 5 s for the automatic restart of PCs or optionally no interruption by opening the circuit the buffer mode is terminated by closing the circuit the buffer mode is started coded Siemens types SITOP UPS1100 (max. 6 via Energy Storage Link) non-coded Siemens types 6EP1935-6M... other manufacturers Output data Output voltage in normal operation Input voltage V in minus approx. 0. V Input voltage V in minus approx. 0. V Output voltage in buffering mode 7 V DC (no load); 4 V (50% battery rated current); V (100% battery rated current); 18.5 V (exhaustive discharge protection) 7 V DC (no load); 4 V (50% battery rated current); V (100% battery rated current); 18.5 V (exhaustive discharge protection) Output +Bat/-Bat in normal operation End-of-charge voltage Rated output current Power boost for 30 ms Extra power for 5 s/min Charging current I-U charging characteristic (first rapid charging current, then charge retention) Automatic temperature-specific setting with SITOP UPS1100 battery modules A 30 A 15 A Max. 3 A automatic adjustment with UPS1100; otherwise selectable 0.3 A, 0.8 A, 3 A I-U charging characteristic (first rapid charging current, then charge retention) Automatic temperature-specific setting with SITOP UPS1100 battery modules A 60 A 30 A Max. 4 A automatic adjustment with UPS1100; otherwise selectable 0.8 A, 1.75 A, 4 A Efficiency for normal operation and >97% >98% charged battery Protection and monitoring Reverse polarity protection against input voltage U in and against batteries against input voltage U in and against batteries Overload / short-circuit protection Yes, restart in normal operation Yes, restart in normal operation Signaling Normal operation/buffer mode LED 1 (OK/BAT) green/yellow and isolated changeover switch 1 LED 1 (OK/BAT) green/yellow and isolated changeover switch 1 Charging status (over 85% charged) LED (BAT>85%) green and isolated changeover switch 3 LED (BAT>85%) green and isolated changeover switch 3 Alarm (not ready for buffering) LED 3 (Alarm) red and isolated changeover switch LED 3 (Alarm) red and isolated changeover switch Battery status LED 4 (BAT.FAULT) red and isolated changeover switch : Battery defective, yellow: selected buffering time not assured, yellow flashing: Overtemperature LED 4 (BAT.FAULT) red and isolated changeover switch : Battery defective, yellow: selected buffering time not assured, yellow flashing: Overtemperature PROFINET interface LED 5 (SF) green and LED 6 (RUN) LED 5 (SF) green and LED 6 (RUN) Ethernet LED 7 (P1) green/yellow and LED 8 (P) green/yellow, link and activity LED 7 (P1) green/yellow and LED 8 (P) green/yellow, link and activity Siemens IK PI 015 /891

113 SITOP DC UPS 4 V DC uninterruptible power supplies SITOP UPS1600 Ordering data Article No. Article No. (continued) DC UPS modules SITOP UPS V/ 10 A SITOP UPS V/ 0 A General data Radio interference level (EN 550) / Class B / Noise immunity to EN Class B / Noise immunity to EN noise immunity Safety class Class III (ext. circuit and power supply unit: SELV in accordance with EN required) Class III (ext. circuit and power supply unit: SELV in accordance with EN required) Degree of protection (EN 6059) IP0 IP0 Ambient temperature during operation C (derating from 60 C) C (derating from 60 C) with natural convection Transport/storage temperature C C Dimensions (W x H x D) in mm 50 x 15 x x 15 x 15 Weight, approx. 0.4 kg without interface, 0.4 kg with USB, 0.45 kg with Ethernet/PROFINET interfaces 0.4 kg without interface, 0.4 kg with USB, 0.45 kg with Ethernet/PROFINET interfaces Installation Snaps onto DIN rail EN x15/7.5 Snaps onto DIN rail EN x15/7.5 Approvals CE, culus, C-Tick; KCC; GL, ABS, ATEX CE, culus, C-Tick; KCC; GL, ABS, ATEX 1) All SITOP 4 V DC power supplies are permissible without restriction Product SITOP UPS1100 battery module 4 V, 1. Ah SITOP UPS1100 battery module 4 V, 3. Ah SITOP UPS1100 battery module 4 V, 7 Ah For SITOP UPS A 10 A 10 A and 0 A Article No. 6EP4131-0GB00-0AY0 6EP4133-0GB00-0AY0 6EP4134-0GB00-0AY0 Recommended end of charge voltage (set automatically by SITOP UPS1600): V DC (> +0 C), V DC (< +0 C) V DC (> +0 C), V DC (< +0 C) V DC (> +0 C), V DC (< +0 C) Charging current max. 0.3 A max. 0.8 A max A Rated output voltage 4 V DC, V DC (no load) 4 V DC, V DC (no load) 4 V DC, V DC (no load) Rated output current 10 A 15 A 30 A Integral battery fuse 15 A/3 V 15 A/3 V 30 A/3 V Signaling LED green: Battery OK, flashing green: Error or warning, OFF: No communication LED green: Battery OK, flashing green: Error or warning, OFF: No communication LED green: Battery OK, flashing green: Error or warning, OFF: No communication Degree of protection (EN 6059) IP00 IP00 IP00 Ambient temperature C C C Transport/storage temperature C C C Service life (when capacity falls to 50% of original capacity), depending on battery temperature, approx. +0 C: 4 years, +30 C: years, +40 C: 1 year, +50 C: 0.5 years +0 C: 4 years, +30 C: years, +40 C: 1 year, +50 C: 0.5 years +0 C: 4 years, +30 C: years, +40 C: 1 year, +50 C: 0.5 years Installation DIN rail or wall mounting DIN rail or wall mounting Wall mounting Dimensions (W x H x D) in mm 89 x 130 x x 169 x x 186 x 110 Weight, approx. 1.9 kg 3.8 kg 6.1 kg Certification CE, curus-recognized, C-Tick; KCC; GL, ABS, ATEX CE, curus-recognized, C-Tick; KCC; GL, ABS, ATEX CE, curus-recognized, C-Tick; KCC; GL, ABS, ATEX Ordering data Article No. Article No. SITOP UPS V/ 10 A With USB interface With Ethernet/ Profinet interfaces SITOP UPS V/ 0 A With USB interface With Ethernet/ Profinet interfaces SITOP UPS1100 battery module 4 V, 1. Ah For SITOP UPS A SITOP UPS1100 battery module 4 V, 3. Ah For SITOP UPS A 6EP4134-3AB00-0AY0 6EP4134-3AB00-1AY0 6EP4134-3AB00-AY0 6EP4136-3AB00-0AY0 6EP4136-3AB00-1AY0 6EP4136-3AB00-AY0 6EP4131-0GB00-0AY0 6EP4133-0GB00-0AY0 SITOP UPS1100 battery module 4 V, 7 Ah For SITOP UPS A and 0 A SITOP UPS1600 starter kit Consisting of: SITOP UPS1600 DC UPS, 4 V DC/10 A with Ethernet/PROFINET interface; SITOP UPS1100 battery module 3. Ah; Industrial Ethernet cable; software tools and documentation on CD 6EP4134-0GB00-0AY0 6EP4134-3AB00-AP0 /89 Siemens IK PI 015

114 Software and tools SIMATIC imap Overview Component-based software tool for configuring the communication in distributed automation solutions For easy graphical configuration of the communication between subsystems and machine-to-machine communication in the production line Based on the PROFINET standard Open for PROFINET devices from various manufacturers on Industrial Ethernet Runs under Windows XP Professional and Windows 7 Ultimate/Professional Benefits The clear advantage of SIMATIC imap over programmed communication lies in the simple programming of the communication (graphically using lines interconnecting the technology interfaces of the devices). Technical specifications Engineering tool SIMATIC imap Current version V3.0 Software class A Application areas Keyword SIMATIC imap is an engineering tool for configuring communication between automation and field devices in distributed automation solutions. Marketing message "Time and cost savings in modular machine and plant construction with Component based Automation." "Modularization and machine-tomachine communication along the production line." Advantages Open component-based engineering tool to the PROFINET standard. Simple communication between intelligent automation and field devices on PROFIBUS DP and on Ethernet. Graphical configuration of communication on PROFIBUS DP and on Ethernet Extremely high reusability of software components (technology modules) Graphical structuring of the plant using "chart-in-chart" function Convenient navigation through the project tree Easy creation and structuring of technology libraries PROFIBUS and Ethernet in the overview of the network view Fast start-up thanks to downloading and testing directly on Ethernet (also of PROFIBUS slaves) Online display of values of the technology modules on the interfaces and in the variable table Diagnosis of communication in the diagnostics window Sectors Automotive industry (especially in assembly, conveyor systems and in the paint shop) Complex food and packaging machines Conveyor systems based on PROFIBUS DP Production lines with several interlinked machines Siemens IK PI 015 /893

115 Software and tools SIMATIC imap Technical specifications (continued) Ordering data Article No. Engineering tool Target systems SIMATIC imap SIMATIC S7 CPU 31x- PN/DP and SIMATIC S7 CPU PN/DP (with integrated PROFINET interface. This can be used as a proxy function for the devices of a complete PROFIBUS segment, one line only) SIMATIC WinAC PN (can be used as a proxy function for the devices of a complete PROFIBUS segment, one line only) SIMATIC NET IE/PB Link (can be used as a proxy function for the devices of a complete PROFIBUS segment) SIMATIC NET CP and CP Advanced (for connecting SIMATIC S7-300 to Ethernet), CP443-1 Advanced (for connecting SIMATIC S7-400 to Ethernet) Distributed I/O stations with separate CPU (all intelligent field devices on PROFIBUS such as SIMATIC CPU 313C-DP, CPU 314C-DP, CPU 315-DP, CPU 316-DP, ET 00 IM 151 CPU, ET 00S BM 147 CPU), PROFINET CBA OPC Server (for access from PC applications to data in PROFINET devices) Devices on Industrial Ethernet based on the PROFINET CBA standard SIMATIC OPs (within the components) SIMATIC ProTool/Pro, WinCC or any other visualization system with OPC client function System prerequisites Operating system Windows XP Prof. with Service Pack or Windows 7 Ultimate/Professional; PC administration rights are required for installation PG/PC hardware Pentium processor, 1 GHz or higher Recommended expansion of main RAM: 51 MB or more memory in PG/PC Hard disk space required in PG/PC Approx. 00 MB Software required STEP 7 V5.3 Service Pack 3 or higher PN OPC-Server V6.3 or higher The following software must be installed before imap (included in the imap package): MS Internet Explorer V6.0 Service Pack 1 and higher Adobe Acrobat Reader V5.0 Delivery format Languages English, German, French, Italian and Spanish Single License (SL) Yes Upgrade License (UL) Yes, from V.0 to V3.0 Paper manuals Electronically on CD Authorization/licenses Authorization Yes Single License (SL) Yes Upgrade License (UL) Yes Software Update Service Yes Unlock Copy License No SIMATIC imap V3.0 Target system: CPU 31x- PN/DP, CPU PN/DP, SIMATIC WinAC PN, SIMATIC NET IE/PB Link, SIMATIC NET CP 343-1, SIMATIC NET CP Advanced, SIMATIC NET CP Advanced, distributed I/O devices with own CPU, PROFINET CBA OPC server, devices on the Industrial Ethernet based on the PROFINET CBA standard, SIMATIC OPs, SIMATIC ProTool/Pro Requirements: Windows XP Prof. with Service Pack or Windows 7 Ultimate/Professional; on PG or PC with Pentium processor, min. 1 GHz; STEP 7 V5.3 or higher with Service Pack 3, PN OPC Server V6.3 or higher Type of delivery: German, English, with electronic documentation Floating License 6ES780-0CC04-0YA5 Software Update Service (requires 6ES780-0CC01-0YX current software version) 1) Upgrade to V3.0, floating license 6ES780-0CC04-0YE5 1) For more information on the software update service, see Catalog ST 70. /894 Siemens IK PI 015

116 Software and tools SINEMA server Overview Benefits SINEMA Server is a web-based network monitoring software that significantly reduces the response time to communications problems in industrial networks, and thus avoids downtimes and saves costs. Simple operator input even for plant operators or service personnel, to enable autonomous detection and correction of communications problems Graphical representation of industrial networks (automatic topology detection and layout) Standardized network documentation (reports for inventory, availability and utilization) Simple operation via web browser or via an HMI/SCADA application, without special IT knowledge Network data such as network topology and device information automatically saved to a database Low installation and maintenance costs, especially thanks to the use of pre-installed industrial PCs (Microbox PC) High degree of flexibility for graphical representation thanks to automatic and customizable topology views Monitoring can be adapted to devices and users Reporting and analysis of changes and faults in the network - Alarm messages - Clear visualization - Prevention of downtimes - Error localization Cost savings - Reduced standstill costs - Low procurement costs - Low installation costs - No consequential costs - Scalable licenses Monitoring functionality can be adapted to the application, devices and users - Application-specific structuring and visualization - Intuitive operation via Web browser - Can be integrated into HMI - No specialist IT know-how/it personnel required Automatic documentation of networks - Increased understanding - Continuous logging/documentation - Any time period selectable - Verification of availability Design Product versions The number of Ethernet devices (IP nodes) to be monitored must be taken into account when selecting the software license. The licenses can be combined in any way to increase the number of monitored devices up to a maximum of 500 IP nodes per installation. SINEMA SERVER 50 Supports the diagnosis of up to 50 IP devices SINEMA SERVER 100 Supports the diagnosis of up to 100 IP devices SINEMA SERVER 50 Supports the diagnosis of up to 50 IP devices SINEMA SERVER 500 Supports the diagnosis of up to 500 IP devices SINEMA Server Upgrade (V1) Upgrade SINEMA Server V11 to V1 Note: Each SINEMA Server can display the status of up to 100 other SINEMA Servers. Up to 50,000 devices can thus be monitored. Siemens IK PI 015 /895

117 Software and tools SINEMA server Function Intuitive operation SINEMA Server is network management for industry. Attention was paid here to the most important functions for the industrial environment, and implementation is with a clear interface for intuitive operation. Users can monitor their networks in the shortest time possible. Costly and time-intensive IT training is not necessary. Automatic device detection and generation of network topologies With the help of DCP and SNMP, SINEMA Server automatically detects PROFINET and Ethernet devices on the network and represents them graphically in a Web browser. This means the maintenance personnel in process and production plants can monitor the current status of the devices and their connections (topology) at all times without time-consuming configuring. User-specific topology display As well as automatic display of the topology, SINEMA Server also gives users the option of representing the network nodes in any arrangement. These user-specific topologies can also be supplemented with background images (e.g. building or plant diagrams). In the case of faults, this means the relevant network components can be found and, if required, replaced or repaired more quickly. Event-triggered alarms For gap-free and instantaneous monitoring of the network, network messages must be detected immediately and the user must be informed. For this purpose, SINEMA Server offers event handling with which all network event messages are acquired and processed. Users of SINEMA Server are thus supplied with all the important event information concerning the network. User-defined display Different personnel with different roles (e.g. administrators, maintenance personnel, etc.) can use SINEMA Server in their daily work. The administrator defines different groups to whom the appropriate rights and views are assigned. Up to 10 people with different tasks can work simultaneously with SINEMA Server. Comprehensible network reports Network diagnostics encompasses not only the current status of the network, but also the analysis of historical values. SINEMA Server saves to a database all values read out from the network components. Time-based filtering and evaluation with comprehensible reports can then take place. In this way, all past events can also be analyzed and used to prevent future failures. Diagnostics via Web browser Access to network diagnostics should not be locally restricted, particularly in the case of large networks. That's why SINEMA Server has been developed on the basis of a server architecture. This enables access to the network management software via commonly used Web browsers. In this way, the network to be checked can also be diagnosed from any location. This enables the network diagnostics tasks of several plant sections to be bundled in one control room. Integration into HMI/SCADA systems To have everything in view, network diagnostics should be integrated in the HMI/SCADA plant solution. SINEMA Server offers full integration of the topology via the Web browser. In addition, all parameters such as warnings and faults can be transferred via the integrated OPC interface. This enables users to integrate network diagnostics into HMI/SCADA systems without a high engineering outlay. /896 Siemens IK PI 015

118 Software and tools SINEMA server Function (continued) SCALANCE W788-1 M1 SINEMA Server HMI/SCADA Internet Webbrowser access via Intenet Webbrowser access via LAN Industrial Ethernet (Twisted Pair) Diagnostics via Web browser Integration in HMI/SCADA systems G_IK10_XX_10346 The network information prepared by SINEMA Server can be called up by any clients via a Web browser or OPC interface. Adaptable device profiles Users have the option of optimizing the device display by means of the profile concept, particularly for non-siemens network components represented by SINEMA Server via standard SNMP information. Scanning of device-specific data via SNMP can also be set via the profile. This means that an industrial network comprising devices from different manufacturers can be optimally monitored with SINEMA Server. Adaptable quantity structure with up to 50,000 network nodes Different SINEMA Server licenses can be selected depending on the size of the network. SINEMA Server thus monitors large networks with up to 500 stations with one installation. With extremely large production networks, SINEMA Server is able to display up to 100 further SINEMA Servers. In this way, individual production cells can be monitored centrally from a single SINEMA Server station. Ordering data Article No. Article No. SINEMA Server V1 Network monitoring software for industrial Ethernet and PROFINET networks, runtime software, software and electronic manual on DVD (not with download), license key on USB flash memory (not with download); software for installation on PC hardware with Win7 Professional and Windows Server 008 R+SP1, Windows XP/SP3 (3-bit), Windows 7 Professional/Ultimate/ Enterprise SP1 (3/64-bit), and Windows Server 008 R + SP1 (64-bit) English/German/French/Chinese. Other languages possible on request. For 50 devices that can be identified via IP address On DVD Download 1) 6GK1781-1BA1-0AA0 6GK1781-1BA1-0AK0 For 100 devices that can be identified via IP address On DVD Download 1) For 50 devices that can be identified via IP address On DVD Download 1) For 500 devices that can be identified via IP address On DVD Download 1) Upgrade SINEMA Server V11 to V1 On DVD Download 1) 1) For more details of online software delivery, visit: under Ordering Data 6GK1781-1DA1-0AA0 6GK1781-1DA1-0AK0 6GK1781-1JA1-0AA0 6GK1781-1JA1-0AK0 6GK1781-1TA1-0AA0 6GK1781-1TA1-0AK0 6GK1781-AA1-0AA0 6GK1781-AA1-0AK0 Siemens IK PI 015 /897

119 Software and tools PN IO Bus Analyzer Overview Network analysis with the bus analyzer Comprising hardware and software components USB memory expansion possible Frame recording with 10 ns resolution Automatic PROFINET analysis Online value tracking Packet generator with feedback analysis Control interface using script or TCP commands Benefits Direct and immediate online analysis in real time and precise statement of the quality of the network. Recording at all speeds without losses and exact time stamping by hardware-based processing. When analyzing and monitoring PROFINET components, it is possible to match and verify the frame structure, the frame times and the frame synchronization. Fast error analyses and improved performance in plant operation, in particular in networks in which products of different vendors are being used. Active measurements on the network with a packet generator: Feed in of frame sequences, delay time measurements, network reactions. Simple reproduction or automation of test scenarios / measurements controlled by scripts. Application Bus Analyzer is the analysis tool for Ethernet / PROFINET. It is made up of a hardware component and a Windows application that communicate with each other over Ethernet. The hardware is controlled and has parameters assigned by the application (triggers, filters, start. stop etc.), the application also downloads the recorded data and statistics to the analysis computer where they are interpreted, displayed and saved. The many functions of the bus analyzer are implemented in individual modules. The modular structure allows target-oriented localization of error sources and the detection of weak points long before problems occur. The following modules are available: Frame recording allows the precise recording of frames on Ethernet / PROFINET. PROFINET analysis automatically detects all relevant bus parameters (number of frames, bus cycles, etc.) online in real time and displays them in tables and graphically. Online value tracking allows the user to extract and record any sizes and values of the communication partners from the frame traffic. With the packet generator, recorded or self-generated frame sequences can be fed into the Ethernet network and the reaction of the network measured automatically. Control of all functions by script or a remote interface (Ethernet, TCP) is possible. Design Module in housing without fan (with bracket for mounting on a DIN rail) Power supply 4 V (does not ship with product) Four independent RJ45 analysis interfaces for connection to Ethernet One RJ45 interface for Ethernet connection of the module to the host PC Internal memory with GB (can be set as a ring buffer) Binary hardware inputs and outputs (can be used as trigger inputs and outputs) USB Interface for connection of external storage media Product versions Standard version: Includes the frame recording and PROFINET analysis modules. Premium version: Includes the frame recording, PROFINET analysis, online value tracking and packet generator modules. The option of controlling with a script or by applications is available with both variants. /898 Siemens IK PI 015

120 Function All bus analyzer functions are controlled by the Bus Analyzer Scope program that ships with the product. This Windows application is connected to the bus analyzer sys module via an Ethernet connection. This is possible via a direct connection, via a network or via a VPN tunnel. The four analysis ports can be used by all function modules but not at the same time. They need to be enabled and assigned to the module being used. On completion of the parameter assignment and after starting the relevant analysis function, the connection between Bus Analyzer and Bus Analyzer Scope can be terminated, in other words, the module then works alone. The frame recording provides a comfortable option of recording communication on Ethernet connections at speeds from Fast Ethernet to gigabit Ethernet. The FPGA technology design of the Bus Analyzer throughout allows error-free, gapless recording of all data with 10 ns time stamping. Even bad frames are not automatically discarded but can be saved and evaluated. The four recording ports can be used independently for recording. If a Test Access Point (TAP) is used to decouple the frames instead of a hub or a switch mirror port, it is possible to interconnect ports; in other words, to bundle their data streams and to save and evaluate them together. To allow the recording to be controlled effectively, freely programmable filters and triggers are available. Apart from standards such as addresses, protocols and patterns, there are also special functions that can trigger on frame timeouts and bad frames (CRC error, undersize error etc.). The integrated hardware inputs can also be used to fire triggers using external binary signals. The data is saved in the internal RAM ( GB capacity) that can also be set as a ring buffer. At the end of the recording, the data is loaded and saved either on the PC via the Ethernet host connection or on an external storage medium connected via USB. If it is necessary to record larger volumes of data, the data can also be streamed to the PC during the recording and saved there. All frames are saved in a file in "pcap" format that can, for example, be read by Wireshark. PROFINET analysis automatically detects all important parameters of a PROFINET system. The Bus Analyzer analyzes the frame traffic in real time in terms of frame type, cycle times and many other important characteristics of the network. During the analysis, all PROFINET nodes are listed in table. The following information is displayed and updated cyclically for each node: PROFINET class, number of sent/received packets, desired cycle time, min/max cycle time, min/max cycle time deviation. The number of frames sent by each node per time unit can be visualized in a cycle time diagram. These are displayed graphically in a distribution curve. At a glance, it is possible to see how well the PROFINET component keeps to the cycle. Software and tools PN IO Bus Analyzer During the analysis of PROFINET IRT, not only the degree to which individual components adhere to the cycle is important, but also the offset of the time of sending within the cycle; in other words, its behavior in conjunction with the other communications partners in the network. The offset diagram can display the distribution curves of all nodes in the cycle to allow a statement to be made regarding the quality within the entire network and the time slice distribution of its nodes. Based on intuitively structured filter menus, the online value tracking provides a simple and uncomplicated means of extracting data from the frame traffic. In contrast to the frame recording, complete frames are not saved here but rather individual values of the relevant communications partners transferred via PROFINET. This means, for example, that the setpoint of a controller, the speed of a motor etc. can be read directly from PROFINET and saved with a time stamp (resolution 10 ns). This is displayed in a table or graphically in the form of a curve that represents the values over time online and in real time. To be able to select the values, the address of the node, the byte position of the value within the frame and the number of bytes to be read must be specified in the filter. The size of the values is limited to 8 bytes. All available formats can be interpreted (binary, integer, analog,...). Up to four values can be recorded simultaneously. There is no limit to the recording time. Siemens IK PI 015 /899

121 Software and tools PN IO Bus Analyzer Function (continued) Ordering data The packet generator allows any Ethernet frames to be injected into the network. To allow this, all four analysis ports are available and are independent of each other. As an alternative, the ports can also be coupled together in pairs as sender/receiver to be able to read in sent frames and to verify the read frames with the sent frames. The frames to be sent are transferred to the module as input in the form of "pcap" files. These inputs can either be generated by recording or can be created as new frames using the integrated pcap editor. Each port has its own menu for setting the relevant send options. Among other things, the packets can be sent as follows: Cyclically (with breaks) As a fixed percentage of bus load With a specified number of repetitions For a specified time etc. At the end of the action, all important parameters (bus load, duration etc.) are output as statistics. The packet generator only executes with the Bus Analyzer without TAP. All the modules listed above can also be remotely controlled by a script. To allow this, each action taken by the user is logged in the integrated script window. The log can be saved, edited and transferred later to Bus Analyzer Scope when this is called. All the instructions in the script are then executed. This allows automated test sequences, for example for setting up test automats. The manual contains an overview of all the script commands that can be used. As an alternative, the script commands can also be transferred using a remote interface (via TCP/IP) from another application to Bus Analyzer Scope. When TCP is used as the transfer interface, the application does not need to be located on the same computer as Bus Analyzer Scope, only in the same network. A sample program in C# ships with the product. Bus analyzer hardware agent for channels without TAP For PROFINET diagnosis (100 Mbit) of fieldbuses or Ethernet diagnosis (up to 1 Gbit) of network segments Bus analyzer hardware agent with -channel TAP For reaction-free PROFINET diagnosis of fieldbuses Article No. 9AE4140-1BA00 9AE4140-1BA01 /900 Siemens IK PI 015

122 Overview STEP 7 V13 (TIA Portal), portal view Engineering / Network management / Diagnostics STEP 7 (TIA Portal) Benefits Powerful programming editors for efficient engineering Scalability across all series of controllers Optimum interaction between the controller, HMI and drive in a working environment Shared data management and uniform symbols System diagnostics as an integral component Variables trace for effective commissioning Scalable and flexible motion control functionality Comprehensive library concept Security Integrated Migration support for existing hardware and software products Application SIMATIC STEP 7 Professional V13 is the easy-to-use, integrated engineering system for the current SIMATIC controllers S7-100, S7-1500, S7-300, S7-400, WinAC, and ET 00 CPU. PLCSIM for simulating the S CPU and WinCC Basic for the configuration of Basic Panels are included in the scope of delivery. SIMATIC STEP 7 Basic V13, the easy-to-use engineering system for the modular SIMATIC S7-100 micro PLC, as well as the associated I/O. It contains SIMATIC WinCC Basic for the configuration of the SIMATIC Basic Panels. STEP 7 V13 thus provides support in all phases of the automation project: Configuring and parameterizing the hardware Specifying the communication Programming in IEC programming editors Configuration of the visualization Test, commissioning and service STEP 7 V13 (TIA Portal), device view: configuring and parameterizing in photographically realistic representation Intuitive, efficient and future-oriented the engineering software for programming the SIMATIC controllers SIMATIC STEP 7 Professional V13 is the engineering system for the SIMATIC controllers S7-100, S7-300, S7-400, WinAC, and also optimally supports the new SIMATIC S controllers. SIMATIC STEP 7 Basic V13 is the engineering system for the S STEP 7 V13 is based on the central engineering framework Totally Integrated Automation Portal (TIA Portal), which offers the user a uniform, efficient and intuitive solution to all automation tasks. Siemens IK PI 015 /901

123 Engineering / Network management / Diagnostics STEP 7 (TIA Portal) Function Excellent integration of the new SIMATIC S controller With its many innovations, the new SIMATIC S controller from the SIMATIC S7 controller family sets new standards for maximum productivity. The SIMATIC S is perfectly integrated into SIMATIC STEP 7 V13 Professional for maximum engineering efficiency. With its unique system performance and PROFINET as standard interface, the SIMATIC S is the new benchmark for performance. Powerful programming editors for efficient engineering STEP 7 V13 provides powerful programming editors with optimized compilers for the programming of the S7 controllers. For all controllers: Ladder diagram (LAD) Function block diagram (FBD) Structured text (SCL) Additionally for SIMATIC S7-1500, S7-300, S7-400, and WinAC: Statement list (STL) New functions such as Instructions for the Variant Pointer, for the programming of flexible library functions Reflexion instructions for reading out program information during runtime (e.g. instance names), local constants etc. enable users to create their applications efficiently. Even complex technological functions, such as controllers or positioning controllers can easily be implemented in the engineering software. Variables trace for effective commissioning The Trace Editor provides the ability to record signals in chronological order from the user program of an S CPU. The graphical evaluation of the signals simplifies, for example, the commissioning of drives and helps search for sporadic errors in the application or user program. Scalable and flexible motion functionality Motion Control applications with SIMATIC STEP 7 V13 and S become child's play, even for beginners. The intuitive graphical user interfaces of the technology objects in STEP 7 V13 offer the best support in the configuration and commissioning of analog and PROFIdrive-capable drives as well as in troubleshooting. The instructions for controlling the motion sequence are standardized according to PLCopen Motion Control. The following functions are supported in STEP 7 V13: Positioning (absolute and relative) Speed specification (e.g. jogging) Homing (active, on-the-fly, etc.) Support of incremental and absolute encoders Comprehensive library concept For the reuse and simple standardization of frequently used program sections, the system has a comprehensive library concept. Elements such as blocks, tags, alarms, HMI graphics, graphic objects, individual modules or entire stations can be stored along with their parameter assignment in local or global libraries. This means they are available for further programming tasks. Security Integrated STEP 7 V13 has password-based know-how protection against unauthorized reading and changing the contents of program blocks. Copy protection offers greater protection against unauthorized copying of program blocks. These can be tied to the serial number of a memory card so that the block can only run if the configured memory card is inserted into the CPU. In addition, multiple user groups with different access rights can be assigned to the controller by means of four different authorization levels. Improved manipulation protection offers a greater degree of security against unauthorized changes to the data transferred between STEP 7 and the controller. Migration support for existing hardware and software products A migration tool integrated in SIMATIC STEP 7 Professional V13 provides support in switching from the S7-300/S7-400 to the S controller and converts the program code automatically. Program code that cannot be converted automatically is logged and can be adapted manually. STEP 7 V1 SP1 projects can continue to be used with STEP 7 V13 in compatibility mode. /90 Siemens IK PI 015

124 Engineering / Network management / Diagnostics STEP 7 (TIA Portal) Technical specifications Type of license Software class Current version STEP 7 Professional / Basic V13 (TIA Portal) Floating license A V13 Compatibility with other SIMATIC products STEP 7 Professional / Basic V13 (incl. WinCC Basic V13) can be installed on a PC in parallel with other versions of STEP 7 V1, V5.4 or V5.5, STEP 7 Micro/WIN, WinCC flexible (from 008) and WinCC (V7.0 SP or higher). Target system SIMATIC S7-100, S7-1500, S7-300, S7-400, WinAC Operating system Windows 7 (64-bit) Windows 7 Professional SP1 Windows 7 Enterprise SP1 Windows 7 Ultimate SP1 Windows 8.1 (64-bit) Windows 8.1 Windows 8.1 Professional Windows 8.1 Enterprise Windows Server (64-bit) Windows Server 008 R StdE SP1 (full installation) Windows Server 01 R StdE (full installation) Computer SIMATIC Field PG M4 PREMIUM or higher (or comparable PC) Processor Intel Core i5-330m 3.3GHz or higher RAM min. 8 GB Hard disk 300 GB SSD Screen 15.6" widescreen display (190 x 1080) Note Includes the IEC programming languages SCL, LAD, FBD, STL and GRAPH Ordering data Article No. Article No. STEP 7 Professional / Basic V13 Target system: SIMATIC S7-100, S7-1500, S7-300, S7-400, WinAC Requirement: Windows 7 Professional SP1 (64 bit), Windows 7 Enterprise SP1 (64 bit), Windows 7 Ultimate SP1 (64 bit), Windows 8.1 (64 bit), Windows 8.1 Professional (64 bit), Windows 8.1 Enterprise (64 bit), Windows Server 008 R StdE (full installation), Windows Server 01 StdE (full installation) Form of delivery: German, English, Chinese, Italian, French, Spanish STEP 7 Professional V13, Floating License STEP 7 Professional V13, Floating License, software download incl. license key 1) address required for delivery STEP 7 Professional V13, Trial License 6ES78-1AA03-0YA5 6ES78-1AE03-0YA5 6ES78-1AA03-0YA7 1) For up-to-date information and download availability, see: STEP 7 Professional V13 promotional package Only valid if ordered together with a Software Update Service 6ES7810-5CC04-0YE (STEP 7 Professional and STEP 7 Professional in TIA Portal). PowerPack & upgrade from STEP 7 V5.5 to STEP 7 Professional 010/V13, Floating License. Prerequisite is an existing STEP 7 Software Update Service. PowerPack & upgrade from STEP 7 V5.5 to STEP 7 Professional 010/V13, Floating License. Prerequisite is an existing STEP 7 Software Update Service. Software download incl. license key 1) address required for delivery PowerPack & upgrade from STEP 7 V5.4/V5.5,... to STEP 7 Professional 010/V13, Floating License. Prerequisite is an existing STEP 7 Standard/Professional installation. PowerPack & upgrade from STEP 7 V5.4/V5.5,... to STEP 7 Professional 010/V13, Floating License. Prerequisite is an existing STEP 7 Standard/Professional. Software download incl. license key 1) address required for delivery 6ES78-1AA03-0XC 6ES78-1AE03-0XC 6ES78-1AA03-0XC3 6ES78-1AE03-0XC3 Siemens IK PI 015 /903

125 Engineering / Network management / Diagnostics STEP 7 (TIA Portal) Ordering data Article No. Article No. Upgrade STEP 7 Professional V1 to STEP 7 Professional V13, Floating License Upgrade from STEP 7 Prof. V1 to STEP 7 Professional V13, Floating License, software download incl. license key 1) address required for delivery Upgrade from STEP 7 Prof. 006/010 to STEP 7 Professional 010/V13, Floating License Upgrade from STEP 7 Prof. 006/010 to STEP 7 Professional 010/V13, Floating License, software download incl. license key 1) address required for delivery PowerPack & upgrade from STEP 7 V5.4/V5.5 to STEP 7 Professional 010/V13, Floating License PowerPack & upgrade from STEP 7 V5.4/V5.5 to STEP 7 Professional 010/V13, Floating License, software download incl. license key 1) address required for delivery PowerPack STEP 7 Basic V13 to STEP 7 Professional V13, Floating License PowerPack STEP 7 Basic V13 to STEP 7 Professional V13, Floating License, software download incl. license key 1) address required for delivery STEP 7 Basic V13, Floating License STEP 7 Basic V13, Floating License, software download incl. license key 1) address required for delivery 6ES78-1AA03-0YE5 6ES78-1AE03-0YE5 6ES78-1AA03-0XE5 6ES78-1AE03-0XE5 6ES78-1AA03-0XC5 6ES78-1AE03-0XC5 6ES78-1AA03-0YC5 6ES78-1AE03-0YC5 6ES78-0AA03-0YA5 6ES78-0AE03-0YA5 Software Update Service For a period of 1 months and for a fixed price, the customer is automatically provided with all upgrades and service packs for each installed software package. The contract is automatically extended by a further year unless canceled at least 1 weeks prior to expiration. Requires the current software version Software Update Service (Standard Edition) ) The delivery is implemented according to the number of ordered SUS products (e.g. 10 upgrade packages with 10 DVDs, 10 USB flash drives, etc.) STEP 7 Professional V1x STEP 7 Professional and STEP 7 Professional in the TIA Portal STEP 7 Basic Software Update Service (Compact Edition) ) The delivery items are combined. For several contracts, only 1 package with 1 data medium set, 1 USB flash drive with the corresponding number of licenses and the corresponding number of COLs will be supplied. Delivery items to be combined must be ordered as one item. STEP 7 Professional V1x STEP 7 Professional and STEP 7 Professional in the TIA Portal STEP 7 Basic Software Update Service (download) ) The upgrades and service packs are available for downloading. address required for delivery STEP 7 Professional V1x STEP 7 Professional and STEP 7 Professional in the TIA Portal STEP 7 Basic 6ES78-1AA00-0YL5 6ES7810-5CC04-0YE 6ES78-0AA00-0YL0 6ES78-1AA00-0YM5 6ES7810-5CC00-0YM 6ES78-0AA00-0YM0 6ES78-1AE00-0YY0 6ES7810-5CC04-0YY 6ES78-0AE00-0YY0 STEP 7 Basic V13, Trial License 6ES78-0AA03-0YA7 Upgrade STEP 7 Basic V1 to STEP 7 Basic V13, Floating License 6ES78-0AA03-0YE5 Upgrade STEP 7 Basic V1 to STEP 7 Basic V13, Floating License, software download incl. license key 1) address required for delivery 6ES78-0AE03-0YE5 1) For up-to-date information and download availability, see: ) For more information on the Software Update Service, see Catalog ST 70. More information Brochures Informative material for downloading can be found on the Internet: Software download For up-to-date information and download availability, see: /904 Siemens IK PI 015

126 Overview Engineering / Network management / Diagnostics STEP 7 STEP 7 trial license If the customer wishes to test that STEP 7 can run on the intended system before it is implemented, the STEP 7 trial license is available for a token fee. STEP 7 Professional STEP 7 Professional provides a software package that, in addition to STEP 7, includes the options of S7-SCL, S7-GRAPH and S7-PLCSIM. STEP 7 Professional is available as an upgrade package for STEP 7. If a common software update package is used, all the languages in the current version can be maintained. Note: Screenshots for the individual tools can be found in the form of a PDF in the detailed information. STEP 7 basic software: The standard tool for the SIMATIC S7, SIMATIC C7 and SIMATIC WinAC automation systems. Makes use of the full performance capabilities of the systems User-friendly functions for all phases of an automation project: - Configuring and parameterizing the hardware - Definition of communication - Programming - Testing, commissioning and service - Documentation, archiving - Operating, diagnostics functions Application STEP 7 basic software is the standard tool for the SIMATIC S7, SIMATIC C7 and SIMATIC WinAC automation systems. It enables the user to use the performance capability of these systems easily and conveniently. STEP 7 contains convenient functions for all phases of an automation project: Configuring and parameterizing the hardware. Specifying the communication. Programming. Test, start-up and service. Documentation, archiving. Operating/diagnostics functions. All functions are supported by the extensive online help. STEP 7 is installed as standard on the Field PG M programming device. It is also available as a software package for a PC installation. For use with a PC, a PC module or PC adapter is required. STEP 7 allows several users to work on a project simultaneously. Write access from more than one user is prevented. Design STEP 7 basic software provides users with different tools for carrying out their automation projects: SIMATIC Manager: For the common and orderly management of all tools and data for the SIMATIC S7, SIMATIC C7 and SIMATIC WinAC Symbol editor: For defining symbolic designations, data types and comments of global tags Hardware configuration: For configuration of the automation system and for parameterization of all settable modules Communication: For configuring connections. Cyclic data transmission between automation components via MPI or for event-driven data transmission by means of either MPI, via PROFIBUS or Industrial Ethernet Information functions: For a fast overview of CPU data and the causes of trouble during execution of a user program For the creation of a user-written program, STEP 7 offers the following field-proven, standardized PLC programming languages: Statement list (STL) Ladder diagram (LAD) Function Block Diagram (FBD) Furthermore, for special tasks, additional programming languages or technology-oriented configurations can be employed. Siemens IK PI 015 /905

127 Engineering / Network management / Diagnostics STEP 7 Function STEP 7 blocks STEP 7 files all user-written programs and all the data required by those programs in blocks. The possibility of calling other blocks within one block, as though they were subroutines, enables the structuring of the user program. This increases considerably the organizational clarity, the comprehensibility and the ease of maintenance of PLC programs. The following types of blocks are available: Organization blocks (OBs) control program execution. - OBs are divided into classes (e.g., time-driven, alarmdriven), independently of the triggering event. These classes have levels of priority. Depending on their respective priority levels, one can interrupt another. - When an OB is started, detailed information about the event initiating the start is provided. This information can be evaluated in the user-written program. Function blocks (FBs) contain the actual user program. - Function blocks can be supplied with different data each time they are called (he so-called instance). These data, as well as internal variables (e.g., for intermediate values) and results are stored in the assigned instance-data block and are automatically managed by the system. When an FB/SFB is called, instance data blocks (instance DBs) are assigned to the block. They are automatically generated when these blocks are compiled. - The user can access these instance data (symbolically as well, of course) from any point in his user program or from an HMI system. Functions (FCs) contain program routines for frequently used functions. - Every function has a fixed function value (a number of initial parameters are possible, in addition to the IEC standard). The output parameters must be processed immediately after the call. Thus functions do not require any instance-data blocks. Data blocks (DBs) are data areas for storing user data. - In addition to the data that is assigned in each case to a function block (instance data), global data can be defined and can be used by any of the software modules (e.g., for recipes). - An elementary or structured data type can be assigned to the components of a data block. Elementary data types are, for example, BOOL, REAL or INTEGER. Structured data types (fields and structures) comprise elementary data types (e.g. a recipe). The data in a data block can be addressed symbolically. This facilitates the programming and the readability of the program. System function blocks (SFBs); function blocks (see above) that are integrated in the CPU's operating system, e.g. SEND, RECEIVE, controller. The variables of the SFBs are also filed in IDBs. System functions (SFCs); functions (see above) that are integrated in the CPU's operating system, e.g., time functions, block transfer. System data blocks (SDBs) are data for the CPU's operating system containing the system settings, e.g., module parameters. Tools SIMATIC Manager The SIMATIC Manager manages all data belonging to an automation project, regardless of the target system (SIMATIC S7, SIMATIC C7 or SIMATIC WinAC) on which they are implemented. It provides a common entry point for all SIMATIC S7, C7 or WinAC tools. The SIMATIC software tools that are necessary for processing the selected data are automatically started by SIMATIC Manager. Symbol Editor With the tool Symbol Editor all global variables (in contrast to the local formal parameters that are declared when the blocks are programmed) are managed. The following functions are available: Definition of symbolic designations and comments for the process signals (inputs/outputs), flags and blocks Sorting functions Data exchange with other Windows programs. The symbol charts that are generated when this tool is used are available to all applications. Changes to a symbol parameter are therefore automatically recognized by all tools. Hardware configuration The tool Hardware Configuration is used for configuring and parameterizing the hardware used for an automation project. The following functions are available: Configuration of the automation system Racks are selected from an electronic catalog and the selected modules are assigned to the required slots in the racks. The configuration of the distributed I/Os is done in the same way as the configuration of the non-distributed I/Os; channel-granular I/O modules are also supported. CPU parameter assignment: Properties such as restart characteristics and cycle-time monitoring can be set menu-driven. multicomputing is supported. The entered data are filed in system data blocks in the CPU. Module parameter assignment: The user can specify all the adjustable parameters of the modules in input screen forms. Adjustments via DIP switches become unnecessary. Parameterization of hardware modules occurs automatically during the CPU's acceleration. Thus, a change of a module can be made without another parameterization. Function module (FM) and communications processor (CP) parameter assignment: This parameterization also occurs within the hardware configuration in the same way as the parameterization of the other modules. For this parameterization hardware-modulespecific screen forms and rules are provided for each FM and CP (is included in the FM/CP functions package). The system prevents faulty inputs by offering only allowed entry options on the parameter assignment screen forms. /906 Siemens IK PI 015

128 Engineering / Network management / Diagnostics STEP 7 Function (continued) System diagnostics System diagnostics offer the user an overview of the status of the automation system. The display can be in two different forms: Display of text messages, which can be output directly and quickly Pixel-graphics display within the Hardware Config display, offering the following options: - Display of general module information (e.g., order number, version, designation) and module status (e.g., faulty) - Display of module faults (e.g., channel faults) of the central I/O and DP slaves - Display of alarms from the diagnostics buffer For CPUs, additional information is displayed: Causes of malfunction during user program execution Display of cycle duration (longest, shortest and last cycle) Display of the reserved and free memory Capabilities and usage of MPI communication Display of the performance data (number of possible inputs/ outputs, flags, counters, timers and blocks) Communication configuration Configuring and display of communication links Time-driven cyclic data transmission via MPI - Selection of communication partners - Entering of data source and data destination in a table. Generation of all system data blocks (SDBs) to be loaded and their complete transmission to all CPUs take place automatically. Event-driven data transmission: - Definition of the communication links - Selection of the communication function blocks (CFBs) from the integrated block library - Parameterization of the selected communication blocks in the customary programming language (e.g., LAD). Programming languages The well-proven programming languages Ladder (LAD), Function Block Diagram (FBD) and Instruction List (IL) are available for programming. Programs that comply with DIN EN can be created in the classical PLC programming languages Ladder Diagram (LAD) and Function Block Diagram (FBD). The user-friendly, pixel-graphics LAD and FBD editors support the programmer with: Uncomplicated and intuitive operation: The creation of ladder diagrams/function block diagrams is characterized by the user-friendliness familiar from PCs, such as drag and drop, cut and paste. Library of predefined complex functions (such as PID controllers) or user-specific standard solutions The Statement List (STL) textual programming language makes it possible for the user to create programs in which operating time and memory location are optimized and which are close to the hardware. When creating these programs, the programmer is supported by the following user-friendly editing functions: Entry option in incremental mode and free text mode: the user can either have each input immediately checked incrementally for correctness, or create the complete program using only symbols in a text editor and subsequently have it translated by means of the appropriate symbol chart. Operation set The STEP 7 programming languages have a comprehensive set of instructions, similar to STEP 5. This allows even complex functions to be programmed easily (i.e., without having great programming knowledge) and quickly The following functions are provided: Binary logic (incl. edge evaluation) Word operation Timers/counters Comparison functions Conversion functions Shift/rotate Mathematical functions (incl. trigonometry, exponents, logarithms) Program control (branches, branch distribution, calls, Master Control Relays). In addition, improved testing and service functions make programming easier: Setting breakpoints (only S7-400) Forcing of inputs/outputs (only S7-400) Rewiring Display of cross-references STEP 7 supports multicomputing with the S7-400 Status functions: Download and testing of blocks directly from the editor Status of several blocks at the same time Search functions: Specific locations within the program can be found quickly using search criteria (such as symbolic name, operand) (XRef). Online Help (F1) is available for all functions and blocks. Note: Screenshot views are available for the individual tools. Siemens IK PI 015 /907

129 Engineering / Network management / Diagnostics STEP 7 Integration Components for connecting a PC to MPI and PROFIBUS The components described below are used to connect programming devices and PCs (incl. notebooks) to PROFIBUS and to the multipoint SIMATIC S7 MPI interface in conjunction with STEP 7. PC adapter USB To connect a PC to the SIMATIC S7 programmable controller via the USB port. For connection to USB 1.1 and.0 interfaces. Can be used for SIMATIC S7-00, S7-300, S7-400 and C7. Supports routing. Automatic transmission rate and profile search. Noticeably improved performance (up to three times faster than the PC adapter via RS 3). Including subsequently updatable firmware (e.g. for function expansions or troubleshooting). Can be used under Windows XP, Windows Vista, Windows 7 (3/64-bit). Scope of delivery: - PC adapter USB. - CD "SIMATIC Software PC Adapter USB" including software and documentation. - USB cable, 5 m. - MPI cable, 0.3 m. CP 551 For programming devices/ PCs/notebooks with PCMCIA slot. PCMCIA slot Type II (3 bit cardbus). Incl. adapter with 9-pin sub-d socket for connection to PROFIBUS. CP 5611/CP 5611-MPI For programming devices/pcs with PCI slot Short PCI card (3 bit). CP 5611-MPI including MPI cable. Components for connecting the PC to Industrial Ethernet The PC modules described below are used to connect programming devices and AT-compatible PCs/notebooks to Industrial Ethernet in conjunction with STEP 7 and SOFTNET-PG (as of V6.0). CP 151 For programming devices/ PCs/notebooks with PCMCIA slot. PCMCIA slot Type II (3 bit cardbus); 10/100 Mbit/s. Incl. adapter with RJ45 socket for connection to Industrial Ethernet. CP 161 For programming devices/pcs with PCI slot Short PCI card (3 bit); 10/100 Mbit/s Incl. RJ45 socket for connection to Industrial Ethernet. Please refer to the respective product catalog for technical information regarding product versions and supported operating systems. You will find additional information about the online connection of PCs and SIMATIC S7/C7 controllers under "SIMATIC NET Communication Systems". /908 Siemens IK PI 015

130 Engineering / Network management / Diagnostics STEP 7 Technical specifications 6ES797-0CB0-0XA0 Supply voltage 4 V DC Yes Input current Current consumption, typ. 100 ma Power Power consumption, typ. max..5 W EMC Interference immunity against discharge of static electricity Interference immunity against Yes discharge of static electricity acc. to IEC Interference immunity to cable-borne interference on the supply lines acc. to IEC Interference immunity on signal lines acc. to IEC Surge immunity on the supply lines acc. to IEC Immunity against high-frequency electromagnetic fields Interference immunity against high-frequency radiation acc. to IEC Immunity against conducted interference induced by high-frequency fields Interference immunity against high frequency current feed acc. to IEC Immunity to magnetic field interference Interference immunity to magnetic fields at 50 Hz Emission of radio interference acc. to EN 55 0 Interference emission acc. to EN 550, class B Yes Yes Yes; 1 kv (to IEC ; surge symm.); kv (to IEC ; surge asymm.) Yes; 10 V/m, 80 to 1000 MHz (to IEC ); 10 V/m, 900 MHz, 1.89 GHz, 50% ED (to IEC ) Yes; 10 V, 9 khz to 80 MHz (to IEC ) 30 A/m; to IEC Yes 6ES797-0CB0-0XA0 Ambient conditions Operating temperature Min. 5 C max. 40 C Permissible temperature change 10 C/h; Operation: 10 K/h; storage/transport: 0 K/h Storage/transport temperature Min. -0 C max. 60 C Relative humidity Operation, min. 5% max. relative humidity 80 % Storage/transport, min. 5% Storage/transport, max. 95 %; At 5 C (no condensation) Vibrations Operation, checked Yes; according to IEC to 58 Hz: Amplitude mm; 58 to 500 Hz: Acceleration 9.8 m/s Transport tested checked Yes; to IEC (packed) 5 to 9 Hz, amplitude 3.5 mm; 9 to 500 Hz, acceleration 9.8 m/s Shock test Shock test Tested to DIN IEC ; Operation: 950 m/s (10 g), 30 ms, 100 Shocks; Transport (packaged): 50 m/s (5 g), 6 ms, 1000 shocks Dimensions Width 105 mm Height 58 mm Depth 6 mm Weights Weight, approx. 100 g Siemens IK PI 015 /909

131 Engineering / Network management / Diagnostics STEP 7 Ordering data Article No. Article No. STEP 7 Version 5.5 STEP 7 reference manuals Target system: SIMATIC S7-300/400, SIMATIC C7, SIMATIC WinAC Requirements: Windows XP Prof., Windows 7 Professional / Ultimate Delivery package: German, English, French, Spanish, Italian; incl. license key on USB stick, with electronic documentation Floating license on DVD Floating License, license key download without software and documentation 1) ; address required for delivery Rental license for 50 hours Rental License for 50 hours, license key download without software and documentation 1) ; address required for delivery Upgrade Floating License 3.x/4.x/5.x to V5.5; on DVD Trial License STEP 7 V5.5; on DVD, 14 day trial STEP 7 Version 5.5 Japanese Target system: SIMATIC S7-300/400, SIMATIC C7, SIMATIC WinAC Requirements: Windows XP Professional Japanese Delivery package: English, Japanese; incl. license key on USB stick, with electronic documentation Floating License Japanese on DVD Upgrade Floating License Japanese 3.x/4.x/5.x to V5.5; on DVD STEP 7 Version 5.5, Chinese Target system: SIMATIC S7-300/400, SIMATIC C7, SIMATIC WinAC Requirements: Windows XP Professional Chinese Delivery package: English, Chinese; incl. license key on USB stick, with electronic documentation Floating License Chinese on DVD Upgrade Floating License Chinese 3.x/4.x/5.x to V5.5; on DVD Documentation package STEP 7 basic information Comprising Getting Started, hardware configuration manual, programming manual, migration manual German English French Spanish Italian 6ES7810-4CC10-0YA5 6ES7810-4CE10-0YB5 6ES7810-4CC10-0YA6 6ES7810-4CE10-0YB6 6ES7810-4CC10-0YE5 6ES7810-4CC10-0YA7 6ES7810-4CC10-0JA5 6ES7810-4CC10-0JE5 6ES7810-4CC10-0KA5 6ES7810-4CC10-0KE5 6ES7810-4CA10-8AW0 6ES7810-4CA10-8BW0 6ES7810-4CA10-8CW0 6ES7810-4CA10-8DW0 6ES7810-4CA10-8EW0 Consisting of STL, LAD and FBD manuals as well as a reference manual for standard and system functions for SIMATIC S7-300/400 German 6ES7810-4CA10-8AW1 English 6ES7810-4CA10-8BW1 French 6ES7810-4CA10-8CW1 Spanish 6ES7810-4CA10-8DW1 Italian 6ES7810-4CA10-8EW1 SIMATIC Manual Collection 6ES7998-8XC01-8YE0 Electronic manuals on DVD, multilingual: LOGO!, SIMADYN, SIMATIC bus components, SIMATIC C7, SIMATIC distributed I/O, SIMATIC HMI, SIMATIC Sensors, SIMATIC NET, SIMATIC PC Based Automation, SIMATIC PCS 7, SIMATIC PG/PC, SIMATIC S7, SIMATIC Software, SIMATIC TDC SIMATIC Manual Collection 6ES7998-8XC01-8YE update service for 1 year Current "Manual Collection" DVD and the three subsequent updates EPROM programming device, 6ES779-0AA00-0XA0 USB prommer For programming SIMATIC memory cards and EPROM modules MPI cable 6ES7901-0BF00-0AA0 For linking SIMATIC S7 and PG through MPI (5 m) Components for connecting a PC to MPI and PROFIBUS For PCs with a free PCI slot: CP 561 6GK1561-AA00 CP 561 MPI 6GK1561-AM00 incl. MPI cable (5 m) For PCs with a free PCMCIA slot: CP 551 6GK1551-AA00 For Windows XP Professional For PCs without a free PCI slot: USB A PC adapter 6GK1571-0BA00-0AA0 for connecting a PG/PC or Notebook to PROFIBUS or MPI; USB cable included in scope of delivery Components for connecting the PC to Industrial Ethernet For PCs with a free PCI slot: Layer Ethernet cards For PCs with a free PCMCIA slot: SOFTNET-IE RNA V7.1 6GK1704-1PW71-3AA0 (Win XP/Vista/Server003) SOFTNET-IE RNA V8.1 6GK1704-1PW08-1AA0 (Win 7/server008) 1) For up-to-date information and download availability, see: /910 Siemens IK PI 015

132 Engineering / Network management / Diagnostics STEP 7 More information Brochures Informative material for downloading can be found on the Internet: Software download For up-to-date information and download availability, see: Siemens IK PI 015 /911

133 PROFINET Technology components Enhanced Real-Time Ethernet Controller ERTEC Overview With the Industrial Ethernet ASICs of the ERTEC family (Enhanced Real-Time Ethernet Controller), devices and systems can be connected to PROFINET without great effort. The highperformance Ethernet controllers with 3-bit microprocessor as well as integral real-time switch for Real Time Ethernet have been specially developed for industrial use. These Ethernet controllers handle all the data transmission for PROFINET with Real-Time (RT) and Isochronous Real-Time (IRT) and thus offload the application processor. Thanks to the integral -port switch (ERTEC 00 and ERTEC 00P) or 4-port switch (ERTEC 400), there are no costs for external switches. Flexible topologies such as star, tree and linear topologies can be implemented without any other external network components. ERTEC 00P with integral -port switch and maximum performance for compact and modular PROFINET field devices. The ERTEC 00P is designed for cycle times up to 31.5 µs. In conjunction with a high-speed ARM 96 CPU, it meets all the requirements for powerful PROFINET implementation. ERTEC 00 with an integral -port switch for developing compact or modular PROFINET field devices. ERTEC 400 with 4 integral ports and one integral PCI interface for developing network components and field devices with specific requirements regarding communication capabilities. The EK-ERTEC 00P PN IO, DK-ERTEC 00 PN IO and DK- ERTEC 400 PN IO development kits enable the uncomplicated development of PROFINET field devices thanks to fast and simple integration of the PROFINET IO functionalities based on the ERTEC. Benefits Full support for the PROFINET functionalities Real-Time (RT) and Isochronous Real-Time (IRT) Space-saving implementation thanks to the high degree of integration Complete communication processing for cyclic data transmission Wide application range thanks to extensive interfaces Openness due to compatibility with IEEE 80 Industry-compatible environmental characteristics (RoHS compatibility) Unlimited support for IT communication and real-time data communication on the same medium. Powerful, integral ARM microprocessor No external network components necessary due to integration of switch in the device Integrated PHYs (for ERTEC00P and ERTEC 00) Technology benefits over standard Ethernet controllers due to the support for time-critical applications such as IRT Development support from the Siemens Competence Centers in Europe and the USA. /91 Siemens IK PI 015

134 PROFINET Technology components Enhanced Real-Time Ethernet Controller ERTEC Technical specifications ERTEC 400 ERTEC 00 ERTEC 00P Transmission rate 10/100 Mbit/s 10/100 Mbit/s 100 Mbit/s Interfaces Ethernet / PHY interface 4 x PHY interface x Ethernet interface (PHY integrated) x Ethernet interface (PHY integrated) or alternatively x PHY interface or alternatively x PHY interface (for connection of optical PHYs) (for connection of optical PHYs) Half/full duplex Half/full duplex Half/full duplex - In connection with the corresponding PHY types: Local Bus Unit (LBU) Support for copper and fiber-optic cables; autosensing; autocrossover Local bus master interface for connecting an external host with access to internal areas of the ERTEC; 16 bit data bit width Support for copper and fiber-optic cables (PHY for copper integrated); autosensing; autocrossover Local bus master interface for connecting an external host with access to internal areas of the ERTEC; 16 bit data bit width Support for copper and fiber-optic cables (PHY for copper integrated); autosensing; autocrossover XHIG (external host interface); 16/3 bit data bit width External memory interface (EMIF) - SDRAM controller 18 MB/16 bit or 56 MB/3 bit 64 MB/16 bit or 18 MB/3 bit 18 MB/16 bit or 56 MB/3 bit - SRAM controller 4 x 16 MB for asynchronous blocks (SRAM, flash, I/O 8/16/3 bit) 4 x 16 MB for asynchronous blocks (SRAM, flash, I/O 8/16/3 bit) 4 x 16 MB for asynchronous blocks (SRAM, flash, I/O 8/16/3 bit) - Chip-select support yes yes yes IO interfaces 3 parameterizable I/O (GPIO); multifunctional outputs 45 parameterizable I/O (GPIO); multifunctional outputs up to 96 parameterizable I/O (GPIO); multifunctional outputs Intelligent switching and yes yes yes PROFINET IRT prioritization/timing ARM processor Integral ARM946 processor 3-bit ARM system 3-bit ARM system 3-bit ARM system - Adjustable operating frequency 50/100/150 MHz 50/100/150 MHz 15/50 MHz Supply voltage Core (VDD Core) 1.5 V +/- 10 % 1.5 V +/- 10 % 1. V +5 %/-0.1 V I/Os (VDD IO) 3.3 V +/- 10 % 3.3 V +/- 10 % 3.3 V +5 %/-10 % External host interface (XHIF) V +5 %/-10 % PHY V +5 %/-10 % External host interface (XHIF) V/3.3 V +5 %/-10 % Perm. ambient conditions Operating temperature -40 C to +85 C -40 C to +85 C -40 C to +85 C Transport/storage temperature -40 C to +85 C -40 C to +85 C -40 C to +85 C Relative humidity Max. 95 % at +5 C Max. 95 % at +5 C Max. 95 % at +5 C Constructional design Housing Plastic FBGA 304 Pin Plastic FBGA 304 Pin Plastic FBGA 400 Pin Pinning Ball Pitch 0.8 mm 0.8 mm 0.8 mm Dimensions (W x H x D) in mm 19 x 1 x x 1 x x 1 x 17 -ERTEC Supported communications protocols General Ethernet protocols PROFINET in combination with a PROFINET Software Stack In accordance with the respective software implementation that uses the ERTEC as Ethernet controller Real-Time communication (RT); Isochronous Real-Time communication (IRT) In accordance with the respective software implementation that uses the ERTEC as Ethernet controller Real-Time communication (RT); Isochronous Real-Time communication (IRT) In accordance with the respective software implementation that uses the ERTEC as Ethernet controller Real-Time communication (RT); Isochronous Real-Time communication (IRT) Siemens IK PI 015 /913

135 PROFINET Technology components Enhanced Real-Time Ethernet Controller ERTEC Ordering data Article No. More information ERTEC 00P ASIC for connection to Switched Ethernet 100 Mbit/s, Ethernet controller with integral -port switch, ARM 96 processor and integral PHYs 10 units (Evaluation Pack) 90 units (individual tray) 450 units (drypack, 5 trays) Evaluation Kit EK-ERTEC 00P PN IO ERTEC 00 ASIC ERTEC 00 for connection to Switched Ethernet 10/100 Mbit/s, Ethernet controller with integral -port switch, ARM 946 processor and integral PHYs 70 units (individual tray), 350 units (drypack, 5 trays), 3500 units (package, 10 drypacks) Development Kit DK-ERTEC 00 PN IO ERTEC 00 PN IO Starter Kit ERTEC 400 ASIC ERTEC 400 for connection to switched Ethernet 10/100 Mbit/s, Ethernet controller with integrated 4-port switch, ARM 946 RISC and PCI interface (V.), data preparation for real-time and isochrone real-time for PROFINET IO 70 units (individual tray), 350 units (drypack, 5 trays), Development kit DK-ERTEC 400 PN IO 6ES7195-0BH00-0XA0 6ES7195-0BH10-0XA0 6ES7195-0BH0-0XA0 6ES7195-3BE00-0YA0 6GK118-0BB01-0AA1 6GK118-0BB01-0AA 6GK118-0BB01-0AA3 6GK1953-0BA00 6ES7195-3BD00-0YA0 6GK1184-0BB01-0AA1 6GK1184-0BB01-0AA 6GK1953-0CA00 You can find further information, technical data and manuals on the Enhanced Real-Time Ethernet Controller ERTEC on the Internet: You can find more information on the Internet at: Support The competent and experienced staff at the PROFINET Competence Centers in Europe and the U.S. offer free telephone advice as well as individual and agreed development and support on-site from the initial information all the way to conclusion of the development with certification. If you have any questions, your contact partner will be pleased to help: Germany and Europe Siemens AG Communication, Development & Certification (ComDeC) P.O. Box Fürth Tel.: +49 (911) Fax: +49 (911) [email protected] USA and International PROFI Interface Center (PIC) One Internet Plaza PO Box 4991 Johnson City, TN Tel.: +1 (43) Fax: +1 (43) [email protected] /914 Siemens IK PI 015

136 Overview PROFINET Technology components Development kits Benefits Easy development of PROFINET field devices with Real-Time (RT) and Isochronous Real-Time (IRT). Perfectly matched hardware and software components. A quick start of the development thanks to the supplied software examples, documentation, and circuit diagrams. Easy creation of a specific GSD file thanks to the supplied example GSD file. Development boards as PN IO device test environment (only with ERTEC). Complete development environment contained in the scope of delivery, including a run-capable example application. Easy portability to any Ethernet controllers and real-time operating systems. With the development packages for PROFINET, compact or modular PROFINET field devices can be developed quickly and with little effort. Depending on the application, different development packages are available. The development packages for the ASICs of the ERTEC family (Enhanced Real-Time Ethernet Controller) are suitable for the development of field devices with an integrated IRT switch (Isochronous Real-Time). The demand for real-time capability, linear topology capability, and for IT integration is therefore met perfectly. With the help of the development package for standard Ethernet controllers, PROFINET devices can be developed on the basis of a standard Ethernet controller. Devices with RT (Real-Time) can be implemented in the field device without special hardware. The PROFIsafe StarterKit permits the implementation of fail-safe devices. In so doing, the PROFIsafe Stack applicatively builds on the PROFINET stack.. Siemens IK PI 015 /915

137 PROFINET Technology components Development kits Ordering data Article No. More information ERTEC development kits Evaluation Kit EK-ERTEC 00P PN IO Development kit DK-ERTEC 00 PN IO Development kit DK-ERTEC 400 PN IO ERTEC 00 PN IO Starter Kit Development kit for standard Ethernet controller PROFIsafe starter kit V3.4 ERTEC ASICs ERTEC 00P ASIC for connection to Switched Ethernet 100 Mbit/s, Ethernet controller with integral -port switch, ARM 96 processor and integral PHYs 10 units (Evaluation Pack) 90 units (individual tray) 450 units (drypack, 5 trays) ERTEC 00 ASIC ERTEC 00 for connection to Switched Ethernet 10/100 Mbit/s, Ethernet controller with integral -port switch, ARM 946 processor and integral PHYs 70 units (individual trays), 350 units (drypack, 5 trays), 3500 units (package, 10 drypacks) ERTEC 400 ASIC ERTEC 400 for connection to Switched Ethernet 10/100 Mbit/s, Ethernet controller with integral 4-port switch, ARM 946 processor and PCI interface (V.) 70 units (individual trays), 350 units (drypack, 5 trays), Accessories PROFINET IO product line license for one product line 6ES7195-3BE00-0YA0 6GK1953-0BA00 6GK1953-0CA00 6ES7195-3BD00-0YA0 6ES7195-3BC00-0YA0 6ES7195-3BF0-0YA0 6ES7195-0BH00-0XA0 6ES7195-0BH10-0XA0 6ES7195-0BH0-0XA0 6GK118-0BB01-0AA1 6GK118-0BB01-0AA 6GK118-0BB01-0AA3 6GK1184-0BB01-0AA1 6GK1184-0BB01-0AA 6ES7195-3BC10-0YA0 You can find more detailed information, technical data, and manuals for ERTEC 00P, ERTEC 00, ERTEC 400, EK-ERTEC 00P, DK/SK-ERTEC 00 PN IO, DK-ERTEC 400 PN IO and DK Standard Ethernet Controller on the Internet: You can find more information on the Internet at: ERTEC 00 PN IO starter kit expansion option The supplied controller test partner SOFTNET PN IO is suitable for developing PROFINET IO Devices with RT thanks to its communication connection via a standard Ethernet interface on the developer PC. For testing the IRT functionality, the controller test partner CP1616 is needed, article number: 6GK1161-6AA01. When using the CP1616, the same evaluation options are available as on the DK-ERTEC 00 PN IO. The necessary and released test software of the CP1616 must be received for successful evaluation with the CP1616. The necessary software components and documentation expansions are available free when you return the completed registration form of the ERTEC 00 PN IO starter kit as well as the delivery notes of the ERTEC 00 PN IO starter kit and CP1616. The software is supplied by the Support Center ComDeC via via a secure download connection following successful registration. Licensing All of the development packages contain a development license which authorizes the user to develop and test PROFINET devices on the basis of the stack provided. For the production of series devices, one product line license must also be obtained for each product line under the Article No. 6ES7195-3BC10-0YA0. For detailed information on the currently applicable licensing rules, contact our Competence Centers ComDeC and PIC. Support The competent and experienced staff at the PROFINET Competence Centers in Europe and the U.S. offer free telephone advice as well as individual and agreed development and support on-site from the initial information all the way to conclusion of the development with certification. If you have any questions, your contact partner will be pleased to help: Germany and Europe Siemens AG Communication, Development & Certification (ComDeC) P.O. Box Fürth Tel.: +49 (911) Fax: +49 (911) [email protected] USA and International PROFI Interface Center (PIC) One Internet Plaza PO Box 4991 Johnson City, TN Tel.: +1 (43) Fax: +1 (43) [email protected] /916 Siemens IK PI 015

138 PROFINET Technology components PROFINET Driver Overview G_ST70_XX_00809 For connecting distributed I/O and drives to user-specific control applications via PROFINET Operation of the control software on a standard PC using the standard Ethernet interface of the PC; Supplied as portable source code and can therefore be used with any operating system Sample application for Windows included in the scope of delivery; uses SIMATIC IPCs as example hardware Benefits Configuration via open XML interface, no engineering tool required (TIA Portal, STEP 7, etc.). Simplified handling when using the TIA Portal Operation on a standard PC using the standard Ethernet interface reduces costs and offers flexibility and performance benefits Delivery as portable source code enables use with different operating systems. This enables connection to a host of userspecific control programs. Supports PROFINET with Real-Time (RT) Cycle times up to 1 ms when using a real-time operating system Ordering data PROFINET Driver For connecting distributed I/O and drives to user-specific control applications via PROFINET Development license Runtime licenses 10 units 50 units 00 units 500 units More information Support Article No. 6ES7195-3AA00-0YA0 6ES7195-3AA10-0XA0 6ES7195-3AA0-0XA0 6ES7195-3AA30-0XA0 6ES7195-3AA40-0XA0 The competent and experienced staff at the PROFINET Competence Centers in Europe and the U.S. offer free telephone advice as well as individual and agreed development and support on-site from the initial information all the way to conclusion of the development with certification. If you have any questions, your contact partner will be pleased to help: Germany and Europe Siemens AG Communication, Development & Certification (ComDeC) P.O. Box Fürth Tel.: +49 (911) Fax: +49 (911) [email protected] USA and International PROFI Interface Center (PIC) One Internet Plaza PO Box 4991 Johnson City, TN Tel.: +1 (43) Fax: +1 (43) [email protected] Siemens IK PI 015 /917

139 Network transitions IE/PB Link PN IO Overview PN DP-M DP-S ASi-M G_IK10_XX_10191 Compact network transition between Industrial Ethernet and PROFIBUS Connection to Industrial Ethernet with 10/100 Mbit/s full/half duplex connection with autosensing for automatic switchover Connection to PROFIBUS with 9.6 kbit/s to 1 Mbit/s incl kbit/s for PROFIBUS PA PROFINET IO proxy; connection of PROFIBUS DP slaves to PROFINET IO controller according to PROFINET standard: - From the viewpoint of the IO controller, all DP slaves are handled like I/O devices with Ethernet interface, i.e. the IE/ PB Link PN IO is their proxy. Cross-network programming device/operator panel communication by S7 routing, i.e. all S7 stations can be remotely programmed by the programming device on the Industrial Ethernet or PROFIBUS. Cross-network access to data of S7 stations for visualization by means of S7 OPC server and S7 routing; - Via the IE/PB Link PN IO access can be made from the PC on the Industrial Ethernet (e.g. for HMI applications with OPC Client interface) by means of S7 OPC server, to all data of the S7 stations on the PROFIBUS. Module replacement without the need for a programming device, using the C-PLUG swap media for backing up the configuration data /918 Siemens IK PI 015

140 Benefits Network transitions IE/PB Link PN IO PROFINET applications Protection of investment due to simple connection of PROFIBUS DP slaves to PROFINET IO controller Enables the use also in plants with PROFIsafe applications Independence from individual vendors through support of the PROFINET standard for distributed field devices SIMATIC HMI SIMATIC S7-400 with CP Advanced PROFINET Industrial Ethernet IE/PB Link PN IO ET 00S ET 00S ET 00S PROFIBUS SINAMICS ET 00S MICRO- MASTER ET 00M Migration for PROFIBUS devices G_IK10_XX_30036 Configuration example of PROFIBUS and PROFINET: PROFIBUS devices can be seamlessly integrated into PROFINET over the IE/PB Link PN IO as proxy. Applications in the case of vertical integration Worldwide access to data of the PROFIBUS stations via Industrial Ethernet and Internet for vertical integration Optimization of a plant from a central location Access to process data from all enterprise levels Loading of STEP 7 programs from a central location Siemens IK PI 015 /919

141 Network transitions IE/PB Link PN IO Application Function As an autonomous component, the IE/PB Link PN IO provides a seamless transition between Industrial Ethernet and PROFIBUS. Using the IE/PB Link PN IO as a proxy, you can continue to use existing PROFIBUS devices (also with PROFIsafe functionality, V.0 or higher) and integrate them into a PROFINET application. The IE/PB Link PN IO also offers the following functions: S7 routing - permits cross-network PG/OP communication, in other words, all S7 stations on Industrial Ethernet or PROFIBUS can be programmed remotely using the programming device - Access can be made to visualization data of the S7 stations on the PROFIBUS from HMI stations on the Industrial Ethernet. Data record routing (PROFIBUS DP) - It is possible, for example, to use SIMATIC PDM (on the PC) on Industrial Ethernet to parameterize and diagnose a PROFIBUS field device via the IE/PB Link PN IO. Design The IE/PB Link PN IO exhibits all the advantages of the SIMATIC design: Compact design; the rugged plastic casing features on the front: - one RJ45 port for connection to Industrial Ethernet. - one 9-pin Sub-D socket for connection to PROFIBUS - one -pin terminal strip for connecting the external supply voltage of 4 V DC. - Diagnostic LEDs Connection is by means of the IE FC RJ45 Plug 180 with 180 cable exit or by means of a standard patch cable Simple mounting; the IE/PB Link PN IO is mounted on an S7-300 DIN rail. Can be operated without a fan Fast device replacement in the event of a fault by using the optional C-PLUG swap medium (not included in scope of supply) PROFINET PROFINET IO proxy; connection of PROFIBUS DP slaves to PROFINET IO controller with real-time property, according to PROFINET standard Additional functionality for vertical integration S7 routing - permits cross-network PG communication, in other words, all S7 stations on Industrial Ethernet or PROFIBUS can be programmed remotely using the programming device. - Access can be made to visualization data of S7 stations on the PROFIBUS from HMI stations on the Industrial Ethernet. Data record routing (PROFIBUS DP) - Using this option, the IE/PB Link PN IO can be used as a router for data records that are forwarded to field devices (DP slaves). SIMATIC PDM (Process Device Manager) is a tool that creates data sets of this type for parameterizing and diagnosing field devices. Application: It is possible, for example, to use SIMATIC PDM (on the PC) on Industrial Ethernet to set parameters and run diagnostics for PROFIBUS PA field device over the IE/PB Link PN IO and DP/PA coupler. The additional functions for vertical integration can also be used in an existing PROFIBUS application without PROFINET for connection to a higher-level Industrial Ethernet. In this case, the IE/PB Link PN IO is used as an additional DP-Master Class on a PROFIBUS segment for linking to the Industrial Ethernet and offers the above functions. Diagnosis Extensive diagnostic options are available via STEP 7 or SNMP, including: Diagnosis of the assigned PROFIBUS field devices; using the IE/PB Link PN IO as a proxy, the connected DP slaves can be diagnosed in the same manner as PROFINET IO devices (even in the user program of the PROFINET IO controller) General diagnostics and statistics functions Connection diagnostics Diagnostic buffer Integration into network management systems through the support of SNMP V1 MIB-II Configuration STEP 7 V5.4 or higher or the TIA Portal V11.0 is required for configuring the full functional scope of the IE/PB Link PN IO. For the IE/PB Link PN IO, STEP 7 automatically generates the necessary parameters, e.g. the ones that assign addresses, and all necessary routing information. The configuration data for PROFINET IO created with STEP 7 is saved on the IO controller. Attention must however be paid to the memory capacity. The initialization data for the Ethernet interface is backed up on the C-PLUG (Configuration Plug) swap media. The IE/PB Link PN IO can be swapped in the event of failure without a programming device, because the relevant user and configuration data is saved on the IO controller or on the C-PLUG. /90 Siemens IK PI 015

142 Network transitions Technical specifications Ordering data Article No. IE/PB Link PN IO Article No. 6GK1411-5AB00 IE/PB Link PN IO 6GK1411-5AB00 Product-type designation Data transmission rates Industrial Ethernet PROFIBUS IE/PB Link PN IO 10/100 Mbit/s autosensing 9.6 kbit/s to 1 Mbit/s incl kbit/s (PROFIBUS PA) Interfaces Connection to Industrial Ethernet - 10BaseT/100BaseT RJ45 Connection to PROFIBUS 9-pin Sub-D socket Connection for power supply -pin terminal block Voltage supply 4 V DC (+/-5 %) Current consumption (at rated voltage) external from 4 V DC, max. 600 ma Power loss approx. 10 W Perm. ambient conditions Operating temperature 0 C + 60 C Transport/storage temperature - 40 C + 70 C Relative humidity, max. 95 % at +5 C Design Module format S7-300 construction Dimensions (W x H x D) in mm 80 x 15 x 10 Weight approx. 600 g Degree of protection IP0 Configuration Configuration software for PROFINET STEP 7/NCM S7, V5.3 SP1 or higher and additional functions Performance data Network transition between Industrial Ethernet and PROFIBUS with PROFINET IO functionality, TCP/IP, S7 routing and data record routing, 10/100 Mbit/s Fast Ethernet, 9.6 to 1 Mbit/s PROFIBUS; including electronic manual on CD-ROM German, English, French, Spanish, Italian IE FC TP Standard Cable GP x (Type A) 4-core, shielded TP installation cable for connection to IE FC Outlet RJ45/IE FC RJ45 Plug; PROFINET-compliant; with UL approval Sold by the meter max. length m minimum order 0 m IE FC RJ45 Plug 180 RJ45 plug connector for Industrial Ethernet with a rugged metal enclosure and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables; with 180 cable outlet; for network components and CPs/CPUs with Industrial Ethernet interface 1 pack = 1 unit 1 pack = 10 units 1 pack = 50 units 6XV1840-AH10 6GK1901-1BB10-AA0 6GK1901-1BB10-AB0 6GK1901-1BB10-AE0 PROFINET communication PROFINET IO performance data Number of DP slaves on the 64 IE/PB Link PN IO (PROFINET IO- Devices for PROFINET IO) Number of DP inputs, max. 048 byte Number of DP outputs, max. 048 byte Additional functionality Number of S7 connections max. 3 Number of DSGW connections max. 3 IE FC Stripping Tool Preadjusted stripping tool for fast stripping of the Industrial Ethernet FC cables CSM 377 Compact Switch Module Unmanaged switch for connection of a SIMATIC S7-300-CPU, ET 00M and up to three further nodes to Industrial Ethernet operating at 10/100 Mbit/s; 4 x RJ45 ports; external 4 V DC power supply, LED diagnostics, S7-300 module including electronic manual on CD-ROM 6GK1901-1GA00 6GK7377-1AA00-0AA0 C-PLUG 6GK1900-0AB00 Swap medium for simple replacement of devices in the event of a fault; for storing configuration or engineering and application data; can be used for SIMATIC NET products with C-PLUG slot Siemens IK PI 015 /91

143 Network transitions IE/PB Link PN IO Ordering data Article No. Article No. PROFIBUS FC Standard Cable GP 6XV1830-0EH10 Standard type with special design for fast mounting, -core, shielded PROFIBUS FastConnect 6GK1500-0FC10 bus connector RS 485 Plug 180 With insulation displacement terminals, with 180 cable outlet, for industrial PC, SIMATIC HMI OP, OLM; max. transmission rate 1 Mbit/s PROFIBUS FastConnect 6GK1905-6AA00 Stripping Tool Preadjusted stripping tool for fast stripping of PROFIBUS FastConnect bus cables S7-300 mounting rail 6ES7390-1AB60-0AA0 S7-300 PS 307 load 6ES7307-1BA01-0AA0 power supply 4 V DC STEP 7 Version 5.5 Target system: SIMATIC S7-300/-400, SIMATIC C7, SIMATIC WinAC Requirements: Windows XP Prof., Windows 7 Professional/Ultimate Type of delivery: German, English, French, Spanish, Italian Including license key on USB stick, with electronic documentation for CP Lean, CP 343-1, CP Advanced, CP ERPC, CP 443-1, CP Advanced, CP RNA Floating License on DVD 6ES7810-4CC10-0YA5 Rental License for 50 hours 6ES7810-4CC10-0YA6 Software Update Service on DVD 6ES7810-4BC01-0YX (requires current software version) Upgrade Floating License 6ES7810-4CC10-0YE5 3.x/4.x/5.x to V5.5; on DVD Trial License STEP 7 V5.5; 6ES7810-4CC10-0YA7 on DVD, 14 day trial STEP 7 Professional V1 Engineering Software Target system: SIMATIC S7-100, S7-1500, S7-300, S7-400, WinAC Requirement: Windows XP Home SP3 (STEP 7 Basic only), Windows XP Professional SP3 (3 bit), Windows 7 Home Premium SP1 (STEP 7 Basic only), Windows 7 Professional SP1 (3/64 bit), Windows 7 Enterprise SP1 (3/64 bit), Windows 7 Ultimate SP1 (3/64 bit), Microsoft Server 003 R Std. SP (3 bit), Microsoft Server 008 Std. SP (3/64 bit) Form of delivery: German, English, Chinese, Italian, French, Spanish for CP , CP Lean, CP 343-1, CP Advanced, CP ERPC, CP 443-1, CP Advanced STEP 7 Professional V1, Floating License STEP 7 Professional V1, Trial License Upgrade STEP 7 Professional V11 to STEP 7 Professional V1, Floating License Upgrade STEP 7 Professional 006/010 to STEP 7 Professional V1, Floating License PowerPack & upgrade from STEP 7 V5.4/V5.5 to STEP 7 Professional V1, Floating License PowerPack STEP 7 Basic V1 to STEP 7 Professional V1, Floating License 6ES78-1AA0-0YA5 6ES78-1AA0-0YA7 6ES78-1AA0-0YE5 6ES78-1AA0-0XE5 6ES78-1AA0-0XC5 6ES78-1AA0-0YC5 /9 Siemens IK PI 015

144 Network transitions Ordering data Article No. Article No. IE/PB Link PN IO STEP 7 Professional Engineering Software V1; software download incl. license key address required for the delivery STEP 7 Professional V1, Floating License STEP 7 Professional V1, Trial License; Upgrade STEP 7 Professional V11 to STEP 7 Professional V1, Floating License Upgrade STEP 7 Professional 006/010 to STEP 7 Professional V1, Floating License PowerPack & upgrade from STEP 7 V5.4/V5.5 to STEP 7 Professional V1, Floating License PowerPack STEP 7 Basic V1 to STEP 7 Professional V1, Floating License 6ES78-1AE0-0YA5 6ES78-1AE0-0YA7 6ES78-1AE0-0YE5 6ES78-1AE0-0XE5 6ES78-1AE0-0XC5 6ES78-1AE0-0YC STEP 7 Professional Engineering Software V13 Target system: SIMATIC S7-300/-400, SIMATIC S7-100/1500, SIMATIC C7, SIMATIC WinAC Requirement: Windows 7 Professional (3 bit) Windows 7 Enterprise (3 bit) Windows 7 Ultimate (3 bit) Microsoft Server 003 R Std. SP (3 bit) Microsoft Server 008 Std. SP (3 bit) Form of delivery: German, English, Chinese, Italian, French, Spanish for CP 143-1, CP , CM 154-1, CP Lean, CP 343-1, CP Advanced, CP ERPC, CP 443-1, CP Advanced STEP 7 Professional V13, Floating License STEP 7 Professional V13, Trial License Upgrade STEP 7 Professional 006/010 to STEP 7 Professional V13, Floating License PowerPack & upgrade STEP 7 V5.4/V5.5 to STEP 7 Professional V13, Floating License PowerPack STEP 7 Basic V13 to STEP 7 Professional V13, Floating License STEP 7 Professional V13, Software Update Service, 1 year; current software version required STEP 7 Professional V13, Software Update Service Compact, 1 year; current software version required STEP 7 Professional Software Update Service; 1 year; for STEP 7 Professional and STEP 7 Professional in the TIA Portal, requires current software version STEP 7 Professional Software Update Service Compact; 1 year; for STEP 7 Professional and STEP 7 Professional in the TIA Portal, requires current software version 6ES78-6ES78-6ES78-6ES78-6ES78-6ES78-6ES78-6ES7810-6ES7810- More information Siemens IK PI 015 /93

145 Industrial Network Services Network validation and monitoring Overview Network validation and monitoring Siemens Industry Services offers network validation and network monitoring services based on reaction-free hardware and the corresponding software for validation, continuous monitoring and diagnosis of the network status. Network validation Validation ensures the operational reliability of the fieldbus systems by checking all of the relevant parameters in great detail. Siemens Industry Services offers a service for testing plant networks for compliance with network standards and for increasing the availability and reliability of the plant through regular validation. This is done on site, after setting up the plant on the end customer's premises. On request, also in close collaboration with the OEM. Network monitoring Scope of services: Creation of an overview of networks and components Checking the components used and the engineering against the specifications of the PI, requirement specification and customer references Visual and mechanical checks on the hardware Checking the physical network structure PROFINET compatibility of the network structure (offline and online) Checking the data communication (failures, cycle times, CRC errors, etc.) PROFIsafe compatibility (optional) Measurements of the PROFINET copper / FOC (optional) cabling Checking the MRP functionality (Media Redundancy Protocol) Report complete with the optimization potential discovered for the network under investigation Industrial Ethernet TAP Network Service Station Microbox with Sinema Server Bus Analyser Agent Bus Analyser Agent Bus Analyser Agent Bus Analyser Agent G_IK10_XX_10003 Network monitoring with bus analyzer /94 Siemens IK PI 015

146 Industrial Network Services Network validation and monitoring Overview (continued) Ordering data Siemens Industry Services offers you the bus analyzer agent PROFINET validation package, analysis hardware for your existing network. Using the associated software, you can monitor your system at the message basic frame level, scan data in real time and integrate it into preexisting software. In order to allow the administration and data PROFINET validation package, For a maximum of networks analysis of several agents distributed throughout the network, standard the "Network Service Station" platform solution is additionally For a maximum of 5 networks available. This allows you to clearly process your data, output PROFINET validation package, alarms in the event of errors, and integrate them into your process visualization system (e.g. WinCC, PCS 7). The integrated, extended fully programmable Reporting function guarantees that a summary of the key parameters is presented to you in a clear form. PROFINET validation package, For a maximum of 10 networks An open and scalable module system allows individual adaptation of the service station to all network sizes and topological For a maximum of 0 networks maximum forms. If necessary, Siemens Industry Service experts will support you in assembling the right combination for you, and in Bus analyzer hardware agent for channels without TAP designing your own reports and the analysis of error messages. For PROFINET diagnosis (100 Mbit) Scope of services: of fieldbuses or Ethernet diagnosis (up to 1 Gbit) Monitoring of PROFINET of network segments (status, events, cycle time, jitter, sporadic errors, etc.) Bus analyzer hardware agent Monitoring of Industrial Ethernet (port status, load, etc.) for channels with TAP Data acquisition in real time with the bus analyzer agent For reaction-free PROFINET (hardware) diagnosis of fieldbuses Network diagnostics in real time Network Service Station Network monitoring STANDARD Backup and restoring of switch configurations NSS standard software for continuous monitoring and reporting of Firmware update for selected network components PROFINET fieldbuses (BANY Agent required). Includes license for WinCC / PCS 7 integration 50 devices and connection of an Reporting operating client. Remote access and support (optional extra, on request) Network Service Station ADVANCED Implementation and installation support (optional extra, on request) Standard functional scope plus the monitoring of Ethernet networks, switch management, port monitoring and long-term archive. Includes license for 50 nodes and connection of an operating client. Network Service Station ADVANCED + Bus Analyzer Hardware agent with -channel TAP incl. NSS, for reaction-free PROFINET diagnosis of fieldbuses, only available within the framework of service contracts Network Service Station OPERATING CLIENT Expansion license for connecting an additional operating client to the Network Service Station Network Service Station POWERPACK Expansion license for connecting an additional 50 devices to the Network Service Station Article No. 9AE4100-4BD30 9AE4100-4BD40 9AE4100-4BD50 9AE4100-4BD60 9AE4140-1BA00 9AE4140-1BA01 9AE4110-1SA00 9AE4110-1SB00 9AE4140-1BA10 9AE4110-1SY00 9AE4110-1SX00 Siemens IK PI 015 /95

147 Partner solutions devicewise Embedded Edition for SIMATIC S7 Overview devicewise Embedded for S7 is a software package that can be loaded into the CP ERPC communications processor as a firmware extension It facilitates intelligent and direct communication from the S7-300 to IT applications at the management level (e.g. databases) No programming is required in SIMATIC Benefits High-speed integration of machine controllers into IT applications, e.g. reading or writing to databases by means of parameterization without any programming effort in the S7-300 Reliable delivery of critical process data by means of store & forward functionality as well as in-built local database. Complex preprocessing of data in the PLC with numerous trigger options Supports standard protocols such as OPC UA or XML-DA directly from the PLC Application devicewise Embedded for S7 offers the database interface of the SIMATIC S7 with CP ERPC to various ERP or MES systems for vertical integration. Database communication devicewise Embedded for S7 establishes direct connections from the PLC to the leading database systems. The user can perform a host of operations on the linked databases, such as: Documentation of production data in the database Updating of existing entries, e.g. recording and saving new data as the production of a component progresses Retrieval of data from the database, e.g. recipes or configuration data for the current production Message-queue communication The software enables the user to communicate directly with the Enterprise Service Bus (ESB) and transfer data from the controller to applications in the enterprise IT system. Messages can be sent and received in ASCII or XML. User-specific data formats can also be defined. Device communication devicewise Embedded for S7 is used predominantly for communication with enterprise applications. In addition, the software can establish connections to other automation devices and transfer data from other PLC systems, RFID readers, or cameras into the data area of the S7-CPU. This is done via the backplane bus and enables flexible mapping of data from the widest variety of devices into the data blocks of the PLC. /96 Siemens IK PI 015

148 Partner solutions devicewise Embedded Edition for SIMATIC S7 Function More information The devicewise Embedded for S7 software includes a userfriendly tool the workbench for the configuration and man- The software is available at: agement of data. ILS Technology LLC; 5300 Broken Sound Blvd. This enables one or more devicewise modules to be addressed Suite 150 without any programming overhead. Boca Raton, FL, U.S.A., The workbench offers a wide range of drag & drop mechanisms Phone: x14 and enables trigger conditions to be defined. This significantly Fax.: reduces the possibilities of errors when entering addresses or field names. In addition, it is possible in the workbench to process raw data into useful information and transport it from pro- You can find further information in the Internet at: [email protected] grammable controllers to databases or message queues in the IT environment of an enterprise. devicewise Embedded for S7 offers the following functions: Direct connection to the following SQL databases: IBM DB IBM DB/400 (for OS/400 systems) PostgreSQL Database Bea Weblogic Oracle Oracle Manufacturing Operations Center Microsoft SQL Server MySQL Direct connection to the following messaging systems: IBM Websphere MQ IBM MQTT IBM SIB/JMS TCP Extensive preprocessing of the data Using devicewise Embedded for S7, extensive preprocessing of data (e.g. mathematical operations, flow diagram processing), the use of a local SQL database, and an in-built FTP server/ client functionality are possible. Error handling and correction by means of: Store and forward for all enterprise transactions notification in the event of faults Fault signaling to the PLC Direct connection to other terminals devicewise Embedded for S7 allows the direct connection of the CP ERPC communications processor to the following terminals: PLC systems (Siemens, Rockwell, Mitsubishi, Omron) Camera systems RFID readers In addition, open-standard protocols such as Modbus TCP, OPC UA or XML-DA are supported. Siemens IK PI 015 /97

149 Notes /98 Siemens IK PI 015

150 PROFIBUS Siemens AG /4 Introduction 3/5 Process or field communication 3/9 Data communication 3/11 Communication overview 3/13 Topologies 3/15 Network components 3/15 Overview of network components 3/17 Network selection criteria 3/0 Connection examples 3/ Electrical networks (RS 485) 3/ PROFIBUS FastConnect 3/4 PROFIBUS bus cables 3/35 ECOFAST bus cables 3/40 Hybrid fieldbus connections 3/4 Energy cables 3/47 RS485 bus connector 3/ T connecting cable 3/ connecting cable 3/54 PROFIBUS M1 and 7/8" connecting cable/connector 3/61 Bus terminals 3/64 Active RS 485 terminating element 3/65 Repeater RS 485 for PROFIBUS 3/67 Diagnostics repeater for PROFIBUS DP 3/70 Electrical networks (PROFIBUS PA) 3/70 Introduction 3/73 SpliTConnect 3/77 Bus cables 3/80 Active field distributors 3/85 Electrical networks (FOUNDATION Fieldbus) 3/85 Bus cables 3/88 Optical networks with OLM 3/88 Overview of FC-FOCs 3/90 FC glass fiber-optic cables 3/95 FC FO termination kit 3/96 Glass fiber-optic cable 3/111 Plastic and PCF fiber-optic cable 3/118 PCF-FOC termination kit 3/11 OLM Optical Link Module 3/134 Optical networks with OBT and integrated interface 3/134 Plastic and PCF fiber-optic cable 3/140 PCF-FOC termination kit 3/143 Optical bus terminal OBT 3/146 System interfaces for SIMATIC S7 3/146 Introduction 3/148 Communication for SIMATIC S /148 CM /15 CM /156 Communication for SIMATIC S /156 CM /161 CP /165 Communication for SIMATIC S /165 CP /169 CP 34-5 FO 3/173 Communication for SIMATIC S /173 CP Extended 3/178 Communication for SIMATIC S7 software Siemens IK PI 015

151 PROFIBUS 3/179 System interfaces for PG/PC/IPC 3/179 Overview 3/180 Communication for PC-based systems 3/180 Performance data 3/181 Connection options to SIMATIC PCs 3/18 CP /187 CP 5613 A3 3/191 CP 5614 A3 3/196 CP 563 3/01 CP 564 3/06 CP 561 3/10 CP 56 3/14 CP /19 SOFTNET for PROFIBUS 3/ OPC server for PROFIBUS 3/5 S7 OPC Redundancy for PROFIBUS 3/7 Software 3/9 PC adapter USB A 3/31 System interfaces for SIMATIC HMI 3/31 System interfaces with WinCC (TIA Portal) 3/3 SIMATIC S7 3/34 SIMATIC WinCC (TIA Portal) Runtime 3/35 WinCC Runtime Communication 3/38 System interfaces with WinCC flexible 3/38 SIMATIC WinCC flexible RT 3/43 System interfaces with WinCC 3/43 SIMATIC WinCC 3/55 Network transistions Ch. IE/PB Link PN IO 3/55 DP/DP coupler 3/56 PA routers Ch. 4 DP/AS-i LINK Advanced Ch. 4 DP/AS-Interface Link 0E Ch. 4 DP/AS-i F-Link 3/61 Industrial Controls 3/61 Soft Starters 3/61 3RW44 soft starters for High-Feature applications 3/63 Software 3/63 Soft Starter ES 3/67 SIRIUS 3RW44 Soft Starter block library for SIMATIC PCS 7 3/70 Motor starters for use in the field, high degree of protection 3/70 M00D motor starters for PROFIBUS 3/73 Communication module, motor starter modules 3/74 Accessories 3/76 Software 3/76 Motor Starter ES 3/80 SIRIUS motor starter block library for SIMATIC PCS 7 3/8 SIMOCODE 3UF Motor Management and Control Devices 3/8 SIMOCODE pro 3UF 3/8 General data 3/88 Basic units 3/90 Expansion modules 3/9 Fail-safe expansion modules 3/93 Accessories 3/300 3UF18 current transformers for overload protection 3/301 SIRIUS 3RK3 Modular Safety System 3/301 General data 3/306 3RK31 central units 3/307 3RK3/33 expansion modules, 3RK35 interface modules, 3RK36 operating and monitoring modules 3/308 Accessories Siemens IK PI 015

152 PROFIBUS Siemens AG /310 Switching and Protection Devices for Power Distribution 3/310 SENTRON Communication- Capable Circuit Breakers 3/311 Power Monitoring 3/311 PC-based Power Monitoring System 3/314 SIMATIC-based Power Data Management System 3/316 SENTRON Measuring Devices 3/316 7KM PAC300 Measuring Devices 3/318 7KM PAC400 Measuring Devices 3/30 7KM PAC Switched Ethernet PROFINET Expansion Module 3/31 7KM PAC PROFIBUS DP Expansion Module 3/3 7KM PAC RS485 Expansion Module 3/33 7KM PAC 4DI/DO Expansion Module for PAC400 3/34 Configuring, Visualizing and Controlling with SIMATIC 3/34 Library 7KM PAC300 for SIMATIC PCS 3/35 Library 3WL/3VL for SIMATIC PCS 7 3/36 Library 7KM PAC300 for SIMATIC WinCC 3/37 Configuring, Visualizing and Controlling with SENTRON 3/37 powermanager 3/331 powerconfig 3/333 Industrial Identification Systems 3/333 ASM 456, SIMATIC RF160C 3/338 Engineering/Network Management/ Diagnostics Ch. STEP 7 Professional/Basic V13 (TIA Portal) Ch. STEP 7 3/338 SIMATIC PDM 3/351 PROFIBUS Components 3/351 PROFIBUS DP ASICs 3/354 Connections/interfaces 3/355 Development kits Siemens IK PI 015

153 3 PROFIBUS Introduction Introduction Overview Bus system - for process and field communication with field devices from different manufacturers - and for data communication acc. to IEC 61158/61784 PROFIBUS the fieldbus standard in production and process engineering comprises: - Specification of the standards for the physical characteristics of the bus and the access procedure - Specification of the user protocol and the user interface Control and monitoring system Controller Laptop Remote access, e.g. via teleservice Numeric Control Motion Control Systems Telecontrol and substation control Offers openness for interfacing to standardized non-siemens components Process or field communication - PROFIBUS DP for fast, cyclic data exchange with field devices - PROFIBUS PA for applications in process automation and in the intrinsically safe area Data communication - PROFIBUS FMS for data communication between programmable controllers of different manufacturers Database Server IWLAN Controller PC/PG/IPC Controller PC Telecontrol and substation control Security S7-100 with CP14-7 PROFINET Industrial Ethernet Notebook Controller Controller PC/PG IWLAN RCoax Cable Access Point Access Point Industrial Ethernet Switches Field device for intrinsically safe area Control and monitoring system PC/PG/IPC Numeric Control Controller Wireless Devices Coupler Link PROFIBUS PA Field devices Compact starter PROFIBUS Protection and monitoring devices RFID system RFID system IO-Link module ASM456 SIMOCODE pro Code reading systems SINAMICS Drives Mobile Panel DP-Slave Power supply LOGO! Motion Control Systems Controller Field devices IO-Link master Link IO-Link module RFID system Protection and monitoring devices Compact starter RF180C Drives RFID system Link Power supply Mobile Panel Client Module Code reading systems Access Point AS-Interface Slaves Compact starter Compact feeder Slaves Signalling column Field device G_IK10_XX_50018 PROFIBUS in the communication landscape Benefits PROFIBUS is a powerful, open, and rugged bus system that ensures trouble-free communication. The system is fully standardized, which enables trouble-free connection of standardized components from a variety of manufacturers. Configuration, commissioning, and troubleshooting can be carried out from any location. This results in user-defined communication relationships that are very versatile, simple to implement, and easy to change. Fast assembly and commissioning on site with the help of the FastConnect wiring system. Continuous monitoring of network components through a simple and effective signaling concept. High security of investment since existing networks can be extended without any adverse effects. High availability through ring redundancy with OLM. 3/4 Siemens IK PI 015 More information Please always note the supplementary conditions for the specified SIMATIC NET products (order numbers 6GK..., 6XV1...), which you can view on the Internet pages below:

154 Overview Communication functions Process or field communication (PROFIBUS DP, PROFIBUS PA) is used to link field devices to a programmable controller, HMI system or control system. Interfacing is performed over integrated interfaces on the CPU or through interface modules (IMs) and communications modules (CPs, CMs). With modern high-performance automation systems, it is often more effective to link more than one PROFIBUS DP line to one system, not just to increase the number of I/O devices that can be connected, but also to enable individual production areas to be handled independently of one another (segmentation). PROFIBUS standardized to IEC 61158/61784 is a high-performance, open, rugged fieldbus system with short response times and the following protocols: PROFIBUS Introduction Process or field communication PROFIBUS DP (Distributed I/O) is used to connect distributed I/O stations, such as SIMATIC ET 00 with extremely fast response times in accordance with the IEC 61158/EN standard. PROFIBUS PA (Process Automation) extends PROFIBUS DP with failsafe transmission technology in accordance with the international standard IEC Siemens IK PI 015 3/5

155 PROFIBUS Introduction Process or field communication Overview (continued) PROFIBUS is used to connect field devices, e.g. distributed I/O devices or drives, to automation systems such as SIMATIC S7, or PCs. PROFIBUS is used when I/O devices are widely distributed on the machine or in the plant (e.g. at the field level) and can be combined into one station (e.g. ET 00), typically more than 16 inputs/outputs. The actuators and sensors are connected to field devices. The field devices are supplied with output data in accordance with the master/slave technique and transfer input data to the programmable controller or PC. High-performance tools such as STEP 7 are available for configuring and parameterizing the I/O devices. Testing and start-up is possible over PROFIBUS DP from any connection point using these tools. 3 DP master e.g. PLC or PC PROFIBUS S7-300 (Slave) with CPU 31x- DP or CP 34-5, CP 34-5 FO Code reading systems ET 00SP S7-100 with CM 14-5 Customer-specific solution with Siemens ASICs PC with ET 00M ET 00iSP RS 485iS coupler S mit CM PROFIBUS ET 00eco DP/PA coupler/link ET 00pro with motor starter Field device for hazardous areas PROFIBUS PA DP/AS-i F Link DP/AS-Interface Link 0E Drive (e.g. SIMODRIVE) DP/AS-i LINK Advanced SITRANS F US Mobile Panel Master Drive Customer-specific solution with Siemens ASICs SITRANS P G_IK10_XX_50108 PROFIBUSDPslaves 3/6 Siemens IK PI 015

156 Overview (continued) DP device types PROFIBUS DP distinguishes between two different master classes and different DP functions: DP Master Class 1 The DP master Class 1 is the central component on PROFIBUS DP. The central controller or PC exchanges information with distributed stations (DP slaves) in a fixed, repeated message cycle. DP Master Class Devices of this type are used (programming, configuration or control devices) during start-up, for configuring the DP system or for controlling the plant during normal operation (diagnostics). A DP master Class can be used, for example, to read the input, output, diagnostics and configuration data of the slaves. DP slave A DP slave is an I/O device that reads in input data and forwards output data to the I/O. The volume of input and output data depends on the device and can be up to 44 bytes. The functional scope can differ between DP masters of Class 1 and or DP slaves. This determines the performance and availability of a communications processor. PROFIBUS Introduction Process or field communication DP-V0 The DP master functions (DP-V0) comprise configuration, parameterization, read input data and write outputs in cycles, read diagnostics data. DP-V1 The additional DP function expansions (DP-V 1) make it possible to perform non-isochronous read and write functions as well as acknowledgement of alarms at the same time as processing cyclic data communication. These extended DP functions comprise acyclic access to the parameters and measured values of a slave (e.g. field devices of process automation and intelligent HMI devices). This type of slave must be supplied with extensive parameter data during start-up and during normal operation. Data transferred in acyclic mode (e.g. parameterization data) are only rarely changed, in comparison to the cyclic measured values, and are transferred at lower priority in parallel with the cyclic high-speed useful data transfer. Alarm acknowledgement by the master ensures reliable transfer of the alarms from DP slaves. DP-V The DP master functions (DP-V) comprise functions for isochronous mode and direct data communication between DP slaves. Isochronous mode Isochronous mode is implemented by means of a signal with a constant bus cycle for the bus system. This isochronous, constant cycle is sent by the master to all bus stations in the form of a global control message. The master and slave can then synchronize their applications with this signal. The jitter of this signal from cycle to cycle must be less than 1 µs for typical drive applications. Direct data communication between DP slaves The publisher/subscriber model is used to implement the direct data communication between slaves. Slaves declared as publishers make their input data (corresponds to response message to their own master) available to other slaves, the subscribers, for reading. Direct slave-to-slave communication is performed cyclically. 3 Siemens IK PI 015 3/7

157 PROFIBUS Introduction Process or field communication Integration 3 DP Master Classes 3/8 Siemens IK PI 015

158 Overview Communication functions Data communication (e.g. PROFIBUS FMS) serves to exchange data between programmable controllers or between a programmable controller and intelligent partners (PC, computers, etc.). The following communication functions are available for this purpose: FMS communication This is a standardized protocol for data communication via PROFIBUS. PROFIBUS FMS (Fieldbus Message Specification) This is ideally suited to communication from different automation systems (e.g. PLCs, PCs) from different manufacturers at the cell level with only a few stations (max. 16). Communication with field devices using the FMS interface is also possible. With the FMS services READ, WRITE and INFORMATION REPORT, read or write access to variables of the communication partner is possible from the user program by means of a variable index or variable name, or the user program can transfer its own variable values to a communications partner. Partial access to variables is supported. The communication is processed over acyclic connections (master-to-master, master-to-slave), over acyclic connections with a slave initiative or with cyclic connections (master-to-slave). The INFORMATION REPORT is can also be used to send a message to all stations on the network using a broadcast service. The FMS service IDENTIFY (request for identification characteristics of the partner) and STATUS (request partner status) can also be activated. PROFIBUS Introduction Data communication OPC-Server The basic principle of OPC (Openness, Productivity & Collaboration) is that OPC client applications communicate with the OPC server over a standardized, open and manufacturer-independent interface. The appropriate OPC servers are included in the scope of supply of the respective communication software. PG/OP communication Comprises integral communication functions that are used by the SIMATIC programmable controllers to perform data communication with HMI devices (e.g. TD/OP) and SIMATIC PG (STEP 7). PG/OP communication is supported by MPI, PROFIBUS and Industrial Ethernet networks. S7 routing With the aid of S7 routing it is possible to use the programming device communication across networks. S7 communication S7 communication is the integral communications function, which has been optimized within the SIMATIC. It enables PCs and workstations to be connected. The maximum volume of useful data per task is 64 KB. S7 communication offers simple, powerful communication services and provides a network-independent software interface for MPI, PROFIBUS and Industrial Ethernet networks. Open communication The open communication (SEND/RECEIVE) allows the SIMATIC S7 controllers to communicate with other SIMATIC S7 and SIMATIC S5 controllers, PCs, and third-party systems. 3 FMS OPC PG/OP S7/S5 Siemens IK PI 015 3/9

159 PROFIBUS Introduction Data communication Overview (continued) System connections For many data terminals, communications processors (CPs) are available that already have the communications functions implemented in the firmware and that therefore relieve the data terminal of communications tasks (e.g. flow control, blocking, etc.). 3 Programmable controller S7-100 Communications processor CM 14-5 CM S7-300 S7-400 CP 34-5 CP 34-5 FO CP CP Basic CP Extended S CM CP PG/PC PROFIBUS CP 5711 CP 561 CP 56 CP 5603 CP 5613 A3 CP 5614 A3 CP 563 CP 564 G_IK10_XX_50005 PROFIBUS system connections for SIMATIC and PC 3/10 Siemens IK PI 015

160 PROFIBUS Introduction Communication overview Function PROFIBUS DP Open communication S7 communication PG/OP communication Usage Time Hardware DP master cl.1 DP master cl. DP slave Send/ Receive S7 routing F system H system Sender Receiver Transfer SIMATIC S7-100 SIMATIC S SIMATIC S7-300 SIMATIC S7-400 S7-100 CPUs No PB SS integrated! CM ) CM 14-5 CPU PN No PB SS integrated! CPU PN No PB SS integrated! CPU PN/DP CM CP ) S7-300 CPUs 3) CP CP FO S7-400 CPUs 3) 3) CP Extended 3 SIMATIC S7mEC CP ) 16 DP slaves maximum ) 3 DP slaves maximum 3) special F- or H-CPUs applies with restrictions G_IK10_XX_50199 Communications overview for SIMATIC Siemens IK PI 015 3/11

161 PROFIBUS Introduction Communication overview Function (continued) Hardware Software Operation system (64 Bit) Operation system (3 Bit) Other operation systems OPC PROFIBUS DP 5) PG/OP S7 communication Open com munication 7) 3 Windows 8 Pro 7) Windows 7 Professional / Ultimate 7) Windows Server 01 7) Windows Server 008 R 7) Windows 8 Pro 7) Windows 7 Professional / Ultimate Vista Business / Ultimate + SP1/ 8) Windows XP Pro + SP3 8) Windows Server SP 8) Windows Server 003 SP 8) DP Master Class 1 DP Master Class DP slave CP with DP-Base 1) 4) CP 5603 (PCI-104) CP 5613 A3 CP 5614 A3 (PCI 3 Bit) CP 563 CP 564 (PCIe x1) DK ) HARDNET-PB DP (DP-5613) 4) 9) 9) 9) 9) HARDNET-PB S7 (S7-5613) S7 OPC Redundancy for PROFIBUS 9) 9) 9) 9) SOFTNET-PB DP ) 3) 3) CP 561 (PCI 3 Bit) SOFTNET-PB DP ) Slave CP 56 (PCIe x1) CP 5711 (USB V.0) SOFTNET-PB S7 S7 OPC Redundancy for PROFIBUS STEP 7 You can find more information on the Internet If you have questions on LINUX projects please contact via [email protected] 1) Included in scope of supply of the hardware ) DP master and DP slaves cannot be operated simul-taneously 3) Master Class 1 and Master Class cannot be operated simultaneously on one CP (Exceptions: CP 5614 A3/CP 564) 4) DP-Base and DP-5613 cannot be operated simultaneously 5) With porting via DK ) SEND/RECEIVE based on the FDL interface 7) on SIMATIC NET-DVD V1 8) on SIMATIC NET CD Edition 008 SP6 9) not with CP 5613 A3/ CP 5614 A3 suitable suitable under certain conditions not applicable G_IK10_XX_50058 Communications overview for PG/PC 3/1 Siemens IK PI 015

162 Overview Siemens offers a comprehensive range of PROFIBUS network components for electrical and optical transmission technology. PROFIBUS is standardized in accordance with IEC 61158/EN for universal automation (PROFIBUS FMS and PROFIBUS DP), and in accordance with IEC for process automation (PROFIBUS PA). Electrical network The electrical network uses a shielded twisted pair cable. The RS 485 interface works with voltage differences. It is therefore less sensitive to interference than a voltage or current interface. With PROFIBUS, the stations are connected to the bus via a bus terminal or a bus connector (max. 3 stations per segment). The individual segments are connected via repeaters. The transmission rate can be set in steps from 9.6 Kbit/s to 1 Mbit/s. The maximum segment length depends on the transmission rate. The electrical network can be configured as a bus or tree structure For applications in the intrinsically-safe area, the transmission technology compliant with IEC is used with PROFIBUS PA. The transmission rate in this case is 31.5 Kbit/s. PROFIBUS Introduction Topologies Characteristics High-grade bus cable Transmission method: RS 485 (acc. to EIA) Bus topology with bus terminals and bus connectors for connecting PROFIBUS stations Transmission method in accordance with IEC 61158/EN for universal automation (PROFIBUS FMS/DP), and in accordance with IEC for the intrinsically-safe area (PROFIBUS PA) The DP transmission system of RS 485 (bit coding by means of differential voltage signals) is converted to IEC (bit coding by means of current signals) using the network components (DP/PA coupler or DP/PA link) Simple, universal installation and grounding concept Easy installation 3 S with CM PC with CP 5613 A3/ CP 561 S7-400 with CP Extended PC/IPC with CP 5614 A3 PROFIBUS DP PROFIBUS DP DP/PA coupler/link ET 00M ET 00S Repeater Intrinsically safe area PROFIBUS PA ET 00iSP RS 485iS coupler Repeater S7-100 with CM 14-5 Drive ET 00pro ET 00pro with motor starter G_IK10_XX_5001 Electrical PROFIBUS network configuration Siemens IK PI 015 3/13

163 3 PROFIBUS Introduction Topologies Overview (continued) Optical network The fiber-optic cable variant of PROFIBUS has the following characteristics: Transmission link is insensitive to electromagnetic influences Suitable for long ranges Galvanic isolation Uses either plastic, PCF or glass fiber-optic cables Avoidance of overvoltage and equipotential bonding problems Optical PROFIBUS with OLMs Using optical link modules (OLMs) it is possible to construct an optical network in a linear, ring, or star topology. The maximum distance between two OLMs is 15 km. The transmission rate can be set in steps from 9.6 Kbit/s to 1 Mbit/s. Optical PROFIBUS with integral interface and OBT The optical PROFIBUS with integral interface and OBT is constructed in a linear topology. A cost-optimized solution is available for this in the form of devices with integral optical interface. Terminal equipment with an RS 485 interface can be connected via an Optical Bus Terminal (OBT). The maximum distance between two nodes is 50 m in the case of plastic fiber-optic cables. Special fiber-optic cables are available to cover distances of up to 400 m. Hybrid network Hybrid electrical and optical networks are possible. The transition between both media is implemented by the OLM. In station-to-station communication on the bus, there is no difference between two-wire technology and fiber-optic technology. A maximum of 17 stations can be connected to one PROFIBUS network. The optical transmission technology offers the following advantages: Fiber-optic cables made of plastic or glass are not susceptible to electromagnetic interference and therefore render the EMC measures required for electrical networks unnecessary No additional lightning protection concept is required in the outdoor area The potentials on the modules are automatically separated thanks to the characteristics of the conductor With fiber-optic cables, long distances to field devices can be bridged. Cabinet OLM/G1 OLM/G1 OLM/G OLM/G1 OLM/G1 PROFIBUS optical PROFIBUS electrical S7-400 with CP Extended S7-300 with CP 34-5 ET 00M Drive ET 00S S7-100 with CM 14-5 PC/IPC with CP 5613 A3/ CP 5614 A3/ CP 563/ CP 564 OP 170B ET 00pro ET 00pro with motor starter G_IK10_XX_50135 Network configuration combining electrical and optical PROFIBUS More information Please always note the supplementary conditions for the specified SIMATIC NET products (order number 6GK..., 6XV1...) that you can view on the Internet pages shown below: 3/14 Siemens IK PI 015

164 PROFIBUS Network components Overview of network components Overview 3 Siemens IK PI 015 3/15

165 PROFIBUS Network components Overview of network components Overview (continued) Options for connecting PROFIBUS cables with plugs, terminals or devices Electrical Optical 3 PROFIBUS FC Standard Cable PROFIBUS FC Standard Cable IS GP PROFIBUS FC Robust Cable PROFIBUS FC Food Cable PROFIBUS FC Ground Cable PROFIBUS FC FRNC Cable PROFIBUS FC Trailing Cable PROFIBUS Festoon Cable PROFIBUS Flexible Cable Connecting cable 830- Connecting cable 830-1T PROFIBUS M1 plug-in cable ECOFAST Hybrid Cable ECOFAST Hybrid Cable GP PROFIBUS Hybrid Standard Cable GP PROFIBUS Hybrid Robust Cable Power Cable 5 x 1.5 PB FC Process Cable 1M bus terminal PROFIBUS FC bus cables PROFIBUS bus cables Connecting cables ECOFAST cable Hybrid cable Power cable PROFIBUS FC Bus cable (PROFIBUS PA) Bus terminal Fiber-optic cable 50/15 μm Fiber-optic cable 6.5/15 μm PCF fiber optic cable 00/30 μm POF-FOC 980/1000 μm Fiber-optic cable with BFOC connector Fiber-optic cable with Simplex connector FO Standard Cable GP FO Trailing Cable FO Trailing Cable GP FO Ground Cable FIBER OPTIC standard cable INDOOR Fiber Optic indoor cable Flexible Fiber Optic trailing cable SIENOPYR marine duplex fi ber-optic cable PCF Standard Cable GP PCF Trailing Cable PCF Trailing Cable GP Plastic fiber optic standard cable Preassembled FOC with BFOC connector Preassembled FOC with simplex connector PB FastConnect connector PB bus connector ECOFAST connector PB M1 plug/ socket (B-coded) Electrical 7/8 Power con PB devices with Sub-D / M1 connector ET 00pro Bus terminal 1M SpliTConnect system BFOC connector Optical PB devices with BFOC connection Simplex connector PB devices with simplex connection G_IK10_XX_ /16 Siemens IK PI 015

166 PROFIBUS Network components Network selection criteria Overview Criteria Electrical network Optical network RS 485 conforming to IEC 61158/ IEC (PA) Plastic PCF Glass EMC Inter-building networking 1) 5) 5) Operating distance ) Suitability for high transmission rate 4) - 3 Simple plug fitting 3) 3) Simple cable laying Equipotential bonding measures required Yes Yes No No No Performance spectrum for special applications Used for moving nodes - 6) 6) 6) 6) Use in intrinsically safe area Summary of network selection criteria for transmission media 1) Lightning protection measures required ) Depending on transmission rate 3) Trained personnel and special tools necessary 4) Careful cable laying necessary 5) Outdoor cable required 6) Trailing cable required suitable partly suitable - not applicable G_IK10_XX_50010 Siemens IK PI 015 3/17

167 PROFIBUS Network components Network selection criteria Overview (continued) Criteria Electrical network Optical network Electrical PROFIBUS with OLM with integr. interface/ OBT Transition media Plastic 1) 3 PCF Glass Shielded two-core cable Distances max. network size 9,6 km 5) 90 km 9,6 km between two nodes up to 1 km 3) up to 15 km ) up to 300 m ) Topology Bus Line Tree Ring Transmission protocols all all DP Connection of nodes via OLM Integrated interfaces 4) Bus terminal Bus connector Electr. network segments connectable 1) Plastic optical fiber is also referred to as polymer optical fiber (POF) ) Depending on type of cable used 3) Depending on data rate used and performance 4) Integrated interfaces (ET 00M, ET 00X) 5) for PROFIBUS PA 1.9 km suitable Irrelevant to this application G_IK10_XX_50133 Selection criteria for electrical and optical networks 3/18 Siemens IK PI 015

168 PROFIBUS Network components Network selection criteria Overview (continued) Electrical network RS 485in accordance with IEC 61158/EN IEC (PA) witholm Optical network with integral interface/ OBT Network topology Transmission media Tools and accessories Bus,tree Shielded twisted-pair cable FastConnect stripping tool Bus,tree Shielded twisted-pair cable for intrinsically-safe and non-intrinsically-safe areas FastConnect stripping tool Linear bus, star, ring Plastic fiber optic cable PCF optic cable Glass fiber optic cable Tools for preparing BFOC connectors for plastic fiber optic cables Linear bus Plastic fiber optic cable PCF optic cable Tools for preparing Simplex connectors for plastic fiber optic cables 3 Connectors Bus connector SpliTConnect system BFOC connector Simplex connector Connection components Bus terminal SpliTConnect system OLM OBT Prepared cables Lightning protection 830-1T connecting cable 830- connecting cable Priomary protection Secondary protection to be implemented through design measures INDOOR cable with BFOC Standard glass cable with BFOC Trailing cable with BFOC Standard PCF cable with BFOC Standard plastic cable with BFOC Not required Standard PCF cable with Simplex connectors and pull cord feature Not required Electrical network segment can be connected via repeater Optical Link Module (OLM) Optical Bus Terminal (OBT) Diagnostics tool Documentation BT 00 hardware test device Manual for PROFIBUS networks Not available Manual for PROFIBUS networks Signal contact and integral measuring sockets; level measuring device on request Manual for PROFIBUS networks Level measuring device on request Manual for PROFIBUS networks G_IK10_XX_50016 PROFIBUS network components and accessories Electrical PROFIBUS Optical PROFIBUS/OLM Optical PROFIBUS/int./OLM Electrical PROFIBUS Repeater OLM OBT Optical PROFIBUS/OLM Optical PROFIBUS/int./OBT OLM OBT OLM OBT + OLM OBT + OLM OBT, integr. optics G_IK10_XX_50017 Transitions between the transmission media Siemens IK PI 015 3/19

169 PROFIBUS Network components Connection examples Integration SIMATIC S7-300 CP 34-5 PROFIBUS FC Bus connector RS PROFIBUS FO Standard Cable G_IK10_XX Typical connection for electrical networking with PROFIBUS FastConnect RS485 bus connector PROFIBUS module e.g. CP 5613 A3 PROFIBUS FC Bus connector RS 485 plug 180 PROFIBUS FC Bus cable 1M bus terminal For loop through of bus nodes to PROFIBUS PROFIBUS FC Bus cable G_IK10_XX_50055 Typical connection for electrical networking with PROFIBUS FastConnect RS485 bus connector or bus terminal PROFIBUS module e.g. CP 5613 A3 PROFIBUS OLM PROFIBUS FC Bus connector RS 485 plug 180 PROFIBUS FC RS 485 bus connector PROFIBUS FC Standard Cable Preassembled glass FOC G_IK10_XX_50056 Connection example of optical networking 3/0 Siemens IK PI 015

170 PROFIBUS Network components Connection examples Integration (continued) OBT FOC with Simplex connector CP 34-5 FO IM151-1 FO OLM Fiber-optic cable with BFOC connector OLM PROFIBUS PCF or plastic fiber-optic cable G_IK10_XX_50061 G_IK10_XX_ Connection example of optical networking with fiber-optic cables and Simplex connectors Connection example of optical networking with fiber-optic cables and BFOC connectors Connection example of an intrinsically-safe network with PROFIBUS PA Siemens IK PI 015 3/1

171 PROFIBUS Electrical networks (RS485) PROFIBUS FastConnect Overview Benefits 3 Shorter connection times for terminals by stripping of the outer cladding and woven shield in one step Installation faults, such as short-circuits between the shield and cores, are excluded Easy assembly due to preset insulation stripping tool (FC stripping tool) Termination can be checked in the assembled state through the transparent cover for the insulation piercing terminals thanks to color coding. Quick and easy assembly of PROFIBUS copper cables Assembly mistakes such as short-circuits between the shield and core are excluded Design The system comprises 3 compatible components: FastConnect bus cables for rapid installation FastConnect stripping tool FastConnect bus connector for PROFIBUS The PROFIBUS FastConnect bus cables can also be connected to conventional bus connectors. Function The FastConnect stripping method enables fast and easy connection of PROFIBUS connectors to the PROFIBUS cables. The special structure of the FastConnect bus cables enables the use of the FastConnect stripping tool with which the outer casing and the woven shield can be stripped in one operation with perfect precision. The cable prepared in this way is connected in the FastConnect bus connector using the insulation displacement method. 3/ Siemens IK PI 015

172 PROFIBUS Electrical networks (RS485) PROFIBUS FastConnect Application PROFIBUS FastConnect is a system for fast and easy assembly of PROFIBUS copper cables G_IK10_XX_50001 Steps in assembling PROFIBUS copper cables with PROFIBUS FastConnect Siemens IK PI 015 3/3

173 PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables 3 Overview Different variants for different application areas (e.g. underground cables, trailing cables, hazardous area Zone 1 and Zone ) High interference immunity thanks to double shielding Flame-retardant bus cable (halogen-free) Easy length measurement thanks to printed meter markings UL approvals Benefits Flexible application possibilities thanks to special bus cables Network is immune to interference thanks to double shielded cables and a uniform grounding concept Time saving due to simple and fast connector assembly with FastConnect cables Silicon-free, therefore particularly suitable for use in the automotive industry (e.g. on paint shop conveyors) Application For the construction of PROFIBUS DP networks, different cable types are offered to suit the different types of applications. The listed bus cables should always be used. For further information on network configuration, see the PROFIBUS network manual. UL approvals UL listing (safety standard) for network cables is especially necessary for the American and Canadian markets. The requirements for the appropriate approvals depend on where the cable is routed within the building. This applies to all cables which have to be routed from a machine to a remote control cabinet and are positioned on cable racks secured on the building. Cables with UL approval have "GP" (General Purpose) added to their name. Ex approval Cables for intrinsically safe PROFIBUS DP applications have "IS" (intrinsically safe) added to their names Design Shielded, twisted-pair cable with circular cross-section The following applies for all PROFIBUS bus cables: The double shield makes it especially suitable for routing through industrial areas with strong electro-magnetic fields System-wide grounding concept can be implemented using the external shield of the bus cable and the grounding terminals on the bus terminal Printed meter marks Cable types The shape of the FastConnect (FC) bus cables is radially symmetric and allows an insulation stripping tool to be used. This means that bus connectors can be assembled quickly and easily. PROFIBUS FC Standard Cable GP: Standard bus cable specially designed for fast installation PROFIBUS FC Standard Cable IS GP: Standard bus cable with special design for quick installation for intrinsically safe distributed I/O systems PROFIBUS FC Robust Cable: Special cable for use in corrosive atmospheres and under severe mechanical loading PROFIBUS FC Food Cable: The PE casing of the cable makes this cable suitable for use in the food and tobacco industry PROFIBUS FC Ground Cable: Special cable for laying underground. It differs from the PROFIBUS bus cable in that it has an additional sheath PROFIBUS FC Flexible Cable Flexible (stranded conductors), halogen-free bus cable with PUR sheath for occasional moving PROFIBUS FC Trailing Cable: Bus cable specially designed for forced motion control in a trailing cable, e.g. with continuously moving machine parts (stranded core) PROFIBUS FC FRNC Cable GP: Two-core, shielded, flame-retardant, halogen-free bus cable with Copolymer outer sheath FRNC (Flame Retardant Non Corrosive) Bus cables without FastConnect technology (due to type of construction) PROFIBUS Festoon Cable GP: Flexible bus cable (stranded cores) specially designed for festoon suspension. For round cables, cable-carrying trolleys are recommended PROFIBUS Torsion Cable Bus cable for highly flexible applications: Special cable (stranded cores) for use on moving parts of machines (5 million torsion movements on 1 m length of cable, ± 180º) PROFIBUS Hybrid Cable GP: Rugged hybrid cable suitable for trailing with two copper conductors for data transmission and two copper conductors for the power supply of ET 00pro SIENOPYR FR marine cable Halogen-free, non-crush, flame-retardant, marine-approved cable for permanent installation on ships and offshore platforms indoors and on open deck. Sold by the meter. 3/4 Siemens IK PI 015

174 PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables Technical specifications Article No. 6XV1830-0EH10 6XV1831-A 6XV1830-0JH10 6XV1830-0GH10 Product-type designation PROFIBUS FC PROFIBUS FC PROFIBUS FC PROFIBUS FC Standard Cable GP Standard Cable IS GP Robust Cable Food Cable Product description Acceptability for application Cable designation Standard bus cable (-core), sold by the meter, in bulk Standard cable specially designed for fast, permanent installation Standard bus cable (-core), sold by the meter, in bulk Used for intrinsically safe distributed I/O systems for permanent installation 0YSY (ST) CY 0YSY (ST) CY 1xx0.64/ VI KF 40 FR 1xx0.64/.55 BL KF40 FR Standard bus cable (-core), sold by the meter, in bulk For use in chemically and mechanically demanding environments Standard bus cable (-core), sold by the meter, in bulk For use in the food, beverages and tobacco industries 0YSY (ST) C11Y 0YSY (ST) CY 1xx0.64/ VI KF 40 FR 1xx0.64/ KF 40 Electrical data Damping ratio per length at 9.6 khz maximum.5 db/km.5 db/km.5 db/km.5 db/km at 38.4 khz maximum 4dB/km 4dB/km 4dB/km 4dB/km at 4 MHz maximum db/km db/km db/km db/km at 16 MHz maximum 4 db/km 4 db/km 4 db/km 4 db/km Impedance Nominal value at 9.6 khz at 38.4 khz for frequency range MHz 0 MHz Relative symmetrical tolerance of the surge impedance at 9.6 khz 10 % 10 % 10 % 10 % of the surge impedance at 38.4 khz 10 % 10 % 10 % 10 % of the surge impedance at 10 % 10 % 10 % 10 % 3 MHz 0 MHz Loop resistance per length 110 /km 110 /km 110 /km 110 /km maximum Shield resistance per length 9.5 /km 9.5 /km 9.5 /km 9.5 /km maximum Capacity per length at 1 khz 8.5 pf/m 8.5 pf/m 8.5 pf/m 8.5 pf/m Operating voltage RMS value 100 V 100 V 100 V 100 V Mechanical data Number of electrical wires Design of shield Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Design of the electrical connection Yes Yes Yes Yes FastConnect Outer diameter of the inner conductor 0.65 mm 0.64 mm 0.65 mm 0.65 mm of the wire insulation.55 mm.55 mm.55 mm.55 mm of the inner sheath of the cable 5.4 mm 5.4 mm 5.4 mm 5.4 mm of the cable sheath 8mm 8mm 8mm 8mm Symmetrical tolerance of outer 0.4 mm 0.4 mm 0.4 mm 0.4 mm diameter of cable sheath Material of the wire insulation PE PE PE PE of the inner sheath of the cable PVC PVC PVC PVC of the cable sheath PVC PVC PE -Note Outer PE sheath particularly suitable for the food sector 3 Siemens IK PI 015 3/5

175 PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables Technical specifications (continued) 3 Article No. 6XV1830-0EH10 6XV1831-A 6XV1830-0JH10 6XV1830-0GH10 Product-type designation PROFIBUS FC PROFIBUS FC PROFIBUS FC PROFIBUS FC Standard Cable GP Standard Cable IS GP Robust Cable Food Cable Color of the insulation of data wires red / green red / green red / green red / green of the cable sheath Violet Blue Violet Black Bending radius with single bend 37.5 mm 37.5 mm 37.5 mm 30 mm with multiple bends 75 mm 75 mm 75 mm 60 mm Traction stress maximum 100 N 100 N 100 N 100 N Weight per length 80 kg/km 80 kg/km 71 kg/km 67 kg/km Permitted ambient conditions Ambient temperature during operating C C C C during storage C C C C during transport C C C C during installation C C C C Burning behaviour Chemical resistance to mineral oil flame resistant according to IEC (Category C) and UL 1685 (CSA FT 4) oil resistant according to IEC (4 hours / 70 C) flame resistant according to IEC (Category C) oil resistant according to IEC (4 hours / 70 C) flame resistant according to IEC oil resistant according to IEC (7x4 hours / 90 C) inflammable oil resistant according to IEC (4 hours / 70 C) to grease Conditional resistance Conditional resistance Resistant Conditional resistance to water Conditional resistance Conditional resistance Conditional resistance Conditional resistance Radiological resistance to Resistant Resistant Resistant Resistant UV radiation Product properties, functions, components general Product feature halogen-free No No No No silicon-free Yes Yes Yes Yes Cable length Standards, specifications, approvals UL/ETL listing with 300 V rating Yes: c(ul)us, Yes: CMG / CL3 / Sun Res Yes: c(ul)us, CMX No CMG / CL3 / Sun Res UL/ETL style with 600 V rating Yes Yes No No Verification of suitability CE mark Yes Yes Yes Yes UL-registration Yes RoHS conformity Yes Yes Yes Yes Marine classification association Germanische Lloyd (GL) No No No No Lloyds Register of Shipping (LRS) No No No No 3/6 Siemens IK PI 015

176 PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables Technical specifications (continued) Article No. 6XV1830-3FH10 6XV1831-K 6XV1830-3EH10 6XV1831-L Product-type designation PROFIBUS FC PROFIBUS FC PROFIBUS FC PROFIBUS FC Ground Cable Flexible Cable Trailing Cable Trailing Cable Product description Special bus cable (-core) with additional outer shield, sold by the meter, in bulk Flexible bus cable (4-core), sold by the meter, in bulk Acceptability for application Used for buried cables For occasionally moved machine parts Cable designation 0YSY (ST) CYY 0YH (ST) C11Y 1xx0.64/ SW KF 40 1xx0.65/ LI KF40 FRNC FC VI Electrical data Highly flexible bus cable (-core), sold by the meter, in bulk Continuous motion control in a cable carrier 0YY (ST) C11Y 1xx0.65/ LI KF 40 FR petrol Highly flexible bus cable (-core), sold by the meter, in bulk Continuous motion control in a cable carrier 0YY (ST) C11Y 1xx0.65/ LI KF 40 FR VT FC Damping ratio per length at 9.6 khz maximum.5 db/km 3dB/km 3dB/km 3dB/km at 38.4 khz maximum 4dB/km 4dB/km 4dB/km 4dB/km at 4 MHz maximum db/km 5 db/km 5 db/km 5 db/km at 16 MHz maximum 4 db/km 49 db/km 49 db/km 49 db/km Impedance Nominal value at 9.6 khz at 38.4 khz for frequency range MHz 0 MHz Relative symmetrical tolerance of the surge impedance at 9.6 khz 10 % 10 % 10 % 10 % of the surge impedance at 38.4 khz 10 % 10 % 10 % 10 % of the surge impedance at 10 % 10 % 10 % 10 % 3 MHz 0 MHz Loop resistance per length 110 /km 133 /km 133 /km 133 /km maximum Shield resistance per length 9.5 /km 15 /km 14 /km 14 /km maximum Capacity per length at 1 khz 8.5 pf/m 8 pf/m 8 pf/m 8 pf/m Operating voltage RMS value 100 V 100 V 100 V 100 V Mechanical data Number of electrical wires Design of shield Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Design of the electrical connection Yes Yes Yes Yes FastConnect Outer diameter of the inner conductor 0.65 mm 0.67 mm 0.67 mm 0.67 mm of the wire insulation.55 mm.56 mm.56 mm.56 mm of the inner sheath of the cable 5.4 mm 5.4 mm 5.4 mm 5.4 mm of the cable sheath 10.8 mm 8mm 8mm 8mm Symmetrical tolerance of outer diameter of cable sheath 0.5 mm 0.4 mm 0.4 mm 0.4 mm Outer diameter of the cable sheath Note The cable (diameter 8.0 mm mm) has an additional, black, outer sheath (diameter 10.8 mm mm) as protection against damage caused by routing underground. Due to outer diameter > 8 mm: Bus connectors can only be connected after the outer sheath has been stripped Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires 3 Siemens IK PI 015 3/7

177 PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables Technical specifications (continued) 3 Article No. 6XV1830-3FH10 6XV1831-K 6XV1830-3EH10 6XV1831-L Product-type designation PROFIBUS FC PROFIBUS FC PROFIBUS FC PROFIBUS FC Ground Cable Flexible Cable Trailing Cable Trailing Cable Material of the wire insulation PE PE PE PE of the inner sheath of the cable PVC FRNC PVC PVC of the cable sheath PE/PVC PUR PUR PUR -Note PVC (cable casing), PE (additional outer sheath) Color of the insulation of data wires red / green red / green red / green red / green of the cable sheath Black Violet Petrol Violet Bending radius with single bend 41 mm 40 mm 40 mm 40 mm with multiple bends 81 mm 10 mm - - with continuous bending mm 10 mm Number of bending cycles Note - - For use in cable carriers, for 3 million bending cycles with a bending radius of 10 mm (15x D) and an acceleration of 4 m/s² Traction stress maximum 100 N 100 N 100 N 100 N Weight per length 117 kg/km 70 kg/km 77 kg/km 77 kg/km Permitted ambient conditions Ambient temperature during operating C C C C during storage C C C C during transport C C C C during installation C C C C Ambient condition for (standard) operation mode - Limited segment length (see manual for PROFIBUS networks) Burning behaviour inflammable flame resistant according to IEC Chemical resistance to mineral oil oil resistant according to IEC (4 hours / 70 C) oil resistant according to IEC (7x4h/90 C) Limited segment length (see manual for PROFIBUS networks) flame resistant according to IEC oil resistant according to IEC (7x4h/90 C) Limited segment length (see manual for PROFIBUS networks) flame resistant according to IEC oil resistant according to IEC (7x4h/90 C) to grease Conditional resistance Resistant Resistant Resistant to water Conditional resistance Conditional resistance Conditional resistance Conditional resistance Radiological resistance to Resistant Resistant Resistant Resistant UV radiation Product properties, functions, components general Product feature halogen-free No Yes No No silicon-free Yes Yes Yes Yes Standards, specifications, approvals UL/ETL listing with 300 V rating No Yes: c(ul)us, CMX Yes: c(ul)us, CMX Yes: CMX UL/ETL style with 600 V rating No No No No Verification of suitability CE mark Yes Yes Yes Yes RoHS conformity Yes Yes Yes Yes Marine classification association Germanische Lloyd (GL) No No No No Lloyds Register of Shipping (LRS) No No No No 3/8 Siemens IK PI 015

178 PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables Technical specifications (continued) Article No. 6XV1830-0LH10 6XV1830-3GH10 6XV1830-0PH10 6XV1830-0MH10 Product-type designation PROFIBUS FC PROFIBUS PROFIBUS SIENOPYR FRNC Cable GP Festoon Cable GP Torsion Cable FR Marine Cable Product description Acceptability for application Cable designation Highly flamed retardant, halogen-free bus cable (-core), sold by the meter, in bulk Halogen-free cable, suitable for use in buildings 0YSH (ST) CH 1xx0.64/ VI KF 5 FRNC FC Flexible bus cable (-core), sold by the meter, in bulk Specially for festoon attachment 0YS (ST) CY 1xx0.65/.56 LI petrol FR Highly flexible bus cable (-core), sold by the meter, in bulk For use in moving machine components 0Y (ST) C 11Y 1xx0.8/ LI FR VI Bus cable (-core), sold by the meter, in bulk M-0Y (ST) CH X 1 x x V Electrical data Damping ratio per length at 9.6 khz maximum.5 db/km 3dB/km,5 db/km 3dB/km at 38.4 khz maximum 4dB/km 4dB/km 3dB/km 5dB/km at 4 MHz maximum db/km 5 db/km 5 db/km db/km at 16 MHz maximum 4 db/km 49 db/km 49 db/km 45 db/km Impedance Nominal value at 9.6 khz at 38.4 khz for frequency range MHz 0 MHz Relative symmetrical tolerance of the surge impedance at 9.6 khz 10 % 10 % 10 % 10 % of the surge impedance at 38.4 khz 10 % 10 % 10 % 10 % of the surge impedance at 10 % 10 % 10 % 10 % 3 MHz 0 MHz Loop resistance per length maximum 110 /km 133 /km 98 /km 110 /km Shield resistance per length maximum 9.5 /km 19 /km 14 /km - Capacity per length at 1 khz 8.5 pf/m 8 pf/m 9 pf/m - Operating voltage RMS value 100 V 100 V 100 V 100 V Mechanical data Number of electrical wires Design of shield Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Design of the electrical connection Yes No No No FastConnect Outer diameter of the inner conductor 0.65 mm 0.67 mm 0.8 mm 0.67 mm of the wire insulation.55 mm.56 mm.56 mm - of the inner sheath of the cable 5.4 mm 5.8 mm 6mm 8mm of the cable sheath 8mm 8mm 8mm 9.8 mm Symmetrical tolerance of outer diameter of cable sheath 0.4 mm 0.3 mm 0.4 mm 0.5 mm Outer diameter of the cable sheath Note Outer diameter > 8 mm: Bus connectors can only be connected after the outer sheath has been stripped Material of the wire insulation PE PE PE PE of the inner sheath of the cable FRNC - - Halogen-free polymer (HM4) of the cable sheath FRNC PVC Halogen-free, cross-linked polymer Color of the insulation of data wires red / green red / green red / green red / green of the cable sheath Violet Petrol Violet Black Bending radius with single bend minimum 60 mm 30 mm 30 mm 98 mm permissible with multiple bends minimum permissible 80 mm 70 mm 60 mm 196 mm with continuous bending - 70 mm 60 mm - Note - - Not suitable for installation in festoons - 3 Siemens IK PI 015 3/9

179 PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables Technical specifications (continued) 3 Article No. 6XV1830-0LH10 6XV1830-3GH10 6XV1830-0PH10 6XV1830-0MH10 Product-type designation PROFIBUS FC PROFIBUS PROFIBUS SIENOPYR FRNC Cable GP Festoon Cable GP Torsion Cable FR Marine Cable Number of torsion cycles with torsion by ± 180 on 1 m cable length Traction stress maximum 100 N 80 N 100 N 100 N Weight per length 7 kg/km 64 kg/km 65 kg/km 110 kg/km Permitted ambient conditions Ambient temperature during operating C C C C during storage C C C C during transport C C C C during installation C C C C Ambient condition for (standard) operation mode Burning behaviour Chemical resistance to mineral oil At ambient temperatures below -15 degrees Celsius, the cable must not be subjected to any movements other than the normal vibration levels encountered on board ship flame resistant according to IEC (Category C), IEC (Category A), EN /, IEC oil resistant according to IEC (4 h / 70 C) flame resistant according to flame resistant according to IEC (Category C) IEC Conditional resistance oil resistant according to IEC (7x4h/90 C) flame resistant according to IEC , IEC 60754, IEC Resistant to diesel fuel according to DIN VDE 51601, ASTM oil No. according to DIN 5351, oil, NATOCode 0178, BWTL / according to VG 9514 Part 4, hydraulic fluid, NATOCode H515, BWTL according to VG 9514 Part 4, cold cleaning solvent, BW-TL according to VG 9514 Part 4, deionized water according to VG 9514 Part 4, deionized water with 3.5% NaCl to grease Conditional resistance Conditional resistance Resistant Resistant to water Conditional resistance Conditional resistance Conditional resistance Conditional resistance Radiological resistance to UV Resistant Resistant Resistant Resistant radiation Product properties, functions, components general Product feature halogen-free Yes No Yes Yes silicon-free Yes Yes Yes Yes Standards, specifications, approvals UL/ETL listing with 300 V rating Yes: c(ul)us, CM / CL3 / Sun Res Yes: CMG / PLCT / Sun Res / Oil Res Yes: CMX UL/ETL style with 600 V rating Yes Yes No No Verification of suitability CE mark Yes Yes Yes - RoHS conformity Yes - Yes - Marine classification association Germanische Lloyd (GL) No No No Yes Lloyds Register of Shipping (LRS) No No No Yes No 3/30 Siemens IK PI 015

180 PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables Technical specifications (continued) Article No. 6XV1860-R 6XV1860-S Product-type designation PROFIBUS Hybrid Standard Cable GP PROFIBUS Hybrid Robust Cable Product description Hybrid cable (data and power cores), sold by the meter, in bulk Hybrid cable (data and power cores), sold by the meter, in bulk Acceptability for application Trailing-type, hybrid cable used for supplying data and power to ET 00pro Rugged cable for supplying data and power to ET 00pro under conditions of high mechanical loading. Cable resistance to weld spatter according to HD. S3 / 5 Cable designation 0Y(ST)C 1xx0.65/ LI LIY-Z Y x1x1.5 VI 0Y(ST)C 1xx0.65/ LI LIH-Z 11Y x1x1.5 VI FRNC Electrical data Damping ratio per length at 9.6 khz maximum 4dB/km 4dB/km at 38.4 khz maximum 4dB/km 4dB/km at 4 MHz maximum 5 db/km 5 db/km at 16 MHz maximum 49 db/km 49 db/km Impedance Nominal value at 9.6 khz at 38.4 khz for frequency range MHz 0 MHz Relative symmetrical tolerance of the surge impedance at 9.6 khz 10 % 10 % of the surge impedance at 38.4 khz 10 % 10 % of the surge impedance at 10 % 10 % 3 MHz 0 MHz Loop resistance per length 138 /km 138 /km maximum Shield resistance per length 10 /km 10 /km maximum Capacity per length at 1 khz 30 pf/m 30 pf/m Operating voltage RMS value 300 V 300 V Conductor cross section of the power wires 1.5 mm² 1.5 mm² Continuous current of the power wires 7.5 A 7.5 A Mechanical data Design of shield Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Number of electrical wires 4 4 Design of the electrical connection No No FastConnect Outer diameter of the wire insulation.56 mm.56 mm of the cable sheath 11 mm 11 mm Symmetrical tolerance of outer 0.5 mm 0.5 mm diameter of cable sheath Material of the wire insulation PE PE Material PVC PUR Color of the insulation of data wires red / green red / green of the power wire insulation Black Black of the cable sheath Violet Violet Bending radius Bending radius with single bend minimum 44 mm 44 mm permissible with multiple bends minimum 15 mm 15 mm permissible Number of bending cycles Note For use in cable carriers, for 1 million bending cycles with a bending radius of 15 mm and an acceleration of.5 m/s² Traction stress maximum 450 N 450 N Weight per length 140 kg/km 135 kg/km For use in cable carriers, for 3 million bending cycles with a bending radius of 15 mm and an acceleration of.5 m/s² 3 Siemens IK PI 015 3/31

181 PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables Technical specifications (continued) 3 Article No. 6XV1860-R 6XV1860-S Product-type designation PROFIBUS Hybrid Standard Cable GP PROFIBUS Hybrid Robust Cable Permitted ambient conditions Ambient temperature during operating C C during storage C C during transport C C during installation C C Burning behaviour flame resistant according to IEC flame resistant according to IEC Chemical resistance to mineral oil Conditional resistance Resistant to grease Conditional resistance Resistant Radiological resistance to not resistant resistant UV radiation Product properties, functions, components general Product feature halogen-free No Yes silicon-free Yes Yes Standards, specifications, approvals UL/ETL listing with 300 V rating Yes: CMG Yes: CMX UL/ETL style with 600 V rating No No Verification of suitability RoHS conformity Yes Yes 3/3 Siemens IK PI 015

182 Ordering data Article No. Article No. PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables PROFIBUS FC Standard Cable GP Standard type with special design for fast mounting, -core, shielded, Sold by the meter; max. length m, minimum order 0 m Not pre-assembled 0 m 50 m 100 m 00 m 500 m m In spool box 50 m 100 m PROFIBUS FC Standard Cable IS GP Standard type with special design for quick assembly, -core, shielded, for intrinsically safe distributed I/O systems Sold by the meter; max. length m, minimum order 0 m PROFIBUS FC Robust Cable -core, shielded Sold by the meter; max. length m, minimum order 0 m PROFIBUS FC Food Cable -core, shielded Sold by the meter; max. length m, minimum order 0 m PROFIBUS FC Ground Cable -core, shielded Sold by the meter; max. length m, minimum order 0 m PROFIBUS FC Flexible Cable -core, shielded Sold by the meter; max. length m, minimum order 0 m PROFIBUS FC Trailing Cable -core, shielded Sold by the meter; max. length m, minimum order 0 m Sheath color: Petrol Sheath color: Violet PROFIBUS Festoon Cable GP -core, shielded Sold by the meter; max. length m, minimum order 0 m PROFIBUS FC FRNC Cable GP -core, shielded, nonflammable, with copolymer outer sheath FRNC Sold by the meter; max. length m, minimum order 0 m 6XV1830-0EH10 6XV1830-0EN0 6XV1830-0EN50 6XV1830-0ET10 6XV1830-0ET0 6XV1830-0ET50 6XV1830-0EU10 6XV1830-1EN50 6XV1830-1ET10 6XV1831-A 6XV1830-0JH10 6XV1830-0GH10 6XV1830-3FH10 6XV1831-K 6XV1830-3EH10 6XV1831-L 6XV1830-3GH10 6XV1830-0LH10 PROFIBUS Torsion Cable 6XV1830-0PH10 -core, shielded Sold by the meter; max. length m, minimum order 0 m PROFIBUS Hybrid Standard 6XV1860-R Cable GP PROFIBUS hybrid cable suitable as trailing cable and resistant to welding spatter, with power conductors (1.5 mm ) for supply of data and power to ET 00pro PROFIBUS Hybrid Robust Cable 6XV1860-S Rugged PROFIBUS hybrid cable suitable as trailing cable and resistant to welding spatter, with power conductors (1.5 mm ) for supply of data and power to ET 00pro Special bus cables SIENOPYR PROFIBUS 6XV1830-0MH10 shipboard cable Copper cable for ships and offshore units Sold by the meter; max. length m, minimum order 0 m Additional components PROFIBUS FastConnect 6GK1905-6AA00 Stripping Tool Preadjusted stripping tool for fast stripping of PROFIBUS FastConnect bus cables PROFIBUS FastConnect Blade 6GK1905-6AB00 Cassettes Spare blade cassettes for PROFIBUS FastConnect stripping tool, 5 units PROFIBUS FastConnect bus connector RS485 with 90 cable outlet With insulation displacement terminals, max. transfer rate 1 Mbit/s Without PG interface 6ES797-0BA5-0XA0 With PG interface 6ES797-0BB5-0XA0 PROFIBUS FastConnect 6GK1500-0FC10 bus connector RS485 Plug 180 With 180 cable outlet, insulation displacement Accessories Lightning protection modules for reliable transmission between buildings with overvoltage protection 1) Basic protection Basic section Protection module Type B Protective housing Terminal element Low-voltage protection Basic section Protection module Terminal element SIMATIC NET Manual Collection 6GK1975-1AA00-3AA0 Electronic manuals for communication systems, communication protocols, and communication products; on DVD; German/English 3 1) Order from: DEHN & Söhne Hans-Dehn-Str Neumarkt/Opf, Germany Siemens IK PI 015 3/33

183 PROFIBUS Electrical networks (RS 485) PROFIBUS bus cables 3 More information Installation instructions The bus cables are supplied by the meter. If a bus segment must be assembled using two sections (e.g. > m segment length), bushings can be used for this purpose (low-impedance connection between cores with clamps, connect shields over a wide area). FastConnect The FastConnect stripping tool can be used to strip the outer sheath and shield of the new FastConnect bus cables to the right length in one step. In this way, the bus connectors (except 6ES797-0BA30-0XA0) can be connected easily and quickly to the bus cable. Migration in discrete automation For many years, PROFIBUS has been the established fieldbus for machines and plants and with the wider use of Ethernet in IT and PROFINET in industry, production systems today would be unimaginable without either of these systems. For migration from PROFIBUS to PROFINET or Industrial Ethernet in discrete automation, Siemens offers a solution in which the existing two-wire cabling for Ethernet communication can be used. For further information on this, please refer to Section and the Internet at: Cable routing: During storage, transport and cable laying, keep both ends sealed with a shrink-on cap. Comply with the permissible bending radii and tensile load! An underground cable must be used if cables are laid outside buildings e.g. directly in the ground, in sand or in concrete building blocks or when routed through protective pipes made of steel or plastic above or below ground. Comply with overvoltage protection guidelines for underground laying. Note: You can order components supplementary to the SIMATIC NET cabling range from your local contact. Technical advice on this subject is available from: J. Hertlein I IA SC CI PRM 4 Phone: 0911/ [email protected] Building SCALANCE X308-M with media module MM99-VD Terminals PROFINET (x line, 100 Mbit/s) up to 300 m SIMATIC S with CM Industrial Ethernet SCALANCE XR34-1M with media module MM99-VD Integration in existing complex Bulkhead firewall SCALANCE X308-M with media module MM99-VD Terminals ET 00M Two-wire line (10 Mbit/s), e.g. PROFIBUS up to 1000 m Terminals, e.g. ET 00 Building ET 00S Terminals Ground cable (10 Mbit/s) up to 1000 m SCALANCE S67-M with media module MM99-VD 3/34 Siemens IK PI 015

184 Overview PROFIBUS Electrical networks (RS485) ECOFAST bus cables Benefits Savings in wiring, installation, commissioning and operation as result of standardized connection system (copper or fiberoptic) with high degree of protection (IP65) With ECOFAST, the turnaround times for offers, planning and engineering of machines and plants can be reduced ECOFAST permits fast and problem-free startup of automation and drive systems Minimization of sources of error by means of standardized interfaces and plug connectors. With ECOFAST plants remain highly available: No interruption of power and fieldbus when replacing equipment. 3 In the ECOFAST system, all devices with bus capability are connected to PROFIBUS DP using the bus cables. The bus cable is implemented as a hybrid cable and contains: PROFIBUS DP in copper RS 485; Four additional copper cores for carrying 4 V DC: - 4 V DC, not switched (for electronics and inputs) - 4 V DC, switched (for outputs, disconnectable e.g. for EMERGENCY OFF) The ECOFAST hybrid cables are sold by the meter or in fixed lengths preassembled with ECOFAST connector (Han Brid) and socket. Technical specifications Article No. 6XV1830-7AH10 6XV1860-P Product-type designation PROFIBUS ECOFAST Hybrid Cable PROFIBUS ECOFAST Hybrid Cable GP Product description ECOFAST hybrid cable (data and power cores), sold by the meter, in bulk ECOFAST hybrid cable (data and power cores), sold by the meter, in bulk Acceptability for application Hybrid cable for connection of ECOFAST stations Hybrid cable for connection of ECOFAST stations, UL approval Cable designation 0Y (ST) 0Y (ST)C 1xx0.65/ LI LIY-Z Y 4x1x1.5 VI C 1 x x 0.65/ LI LIH-Z 11Y 4 x 1 x 1.5 VI FRNC Electrical data Damping ratio per length at 9.6 khz maximum db/m db/m at 38.4 khz maximum db/m db/m at 4 MHz maximum 0.05 db/m 0.05 db/m at 16 MHz maximum db/m db/m Impedance Nominal value at 9.6 khz at 38.4 khz for frequency range MHz 0 MHz Relative symmetrical tolerance of the surge impedance at 9.6 khz 10 % 10 % of the surge impedance at 38.4 khz 10 % 10 % of the surge impedance at 10 % 10 % 3 MHz 0 MHz Loop resistance per length 138 /km 138 /km maximum Shield resistance per length 15 /km 15 /km maximum Capacity per length at 1 khz 30 pf/m 30 pf/m Inductance per length - - Operating voltage RMS value 100 V 600 V Conductor cross section of the power wires 1.5 mm² 1.5 mm² Continuous current of the power wires 1 A 1 A Siemens IK PI 015 3/35

185 PROFIBUS Electrical networks (RS485) ECOFAST bus cables Technical specifications (continued) 3 Article No. 6XV1830-7AH10 6XV1860-P Product-type designation PROFIBUS ECOFAST Hybrid Cable PROFIBUS ECOFAST Hybrid Cable GP Mechanical data Design of shield Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Number of electrical wires 6 6 Design of the electrical connection No No FastConnect Outer diameter of the wire insulation.56 mm.56 mm of the cable sheath 11 mm 11 mm Symmetrical tolerance of outer 0.3 mm 0.3 mm diameter of cable sheath Material of the wire insulation PE PE of the cable sheath PUR PVC Color of the insulation of data wires red / green red / green of the power wire insulation Black Black of the cable sheath Violet Violet Bending radius with multiple bends minimum 8.5 mm 110 mm permissible Number of bending cycles Note For use in cable carriers, for 5 million bending cycles with a bending radius of 8.5 mm (7.5x D) and an acceleration of.5 m/s² Traction stress maximum 300 N 300 N Weight per length 150 kg/km 154 kg/km Permitted ambient conditions Ambient temperature during operating C C during storage C C during transport C C during installation C C Burning behaviour Chemical resistance to mineral oil Conditional resistance Conditional resistance to grease Conditional resistance Conditional resistance Radiological resistance to resistant resistant UV radiation Product properties, functions, components general For use in cable carriers, for 1 million bending cycles with a bending radius of 166 mm (15x D) and an acceleration of 4.0 m/s² Product feature halogen-free Yes Yes silicon-free Yes Yes Standards, specifications, approvals UL/ETL listing with 300 V rating No No UL/ETL style with 600 V rating No Yes: CM / CL3 / SunRes / OilRes Verification of suitability RoHS conformity Yes Yes 3/36 Siemens IK PI 015

186 PROFIBUS Electrical networks (RS485) ECOFAST bus cables Technical specifications (continued) Article No. 6GK1905-0CA00 6GK1905-0CB00 6GK1905-0CC00 6GK1905-0CD00 Product-type designation PB ECOFAST PB ECOFAST PB ECOFAST PB ECOFAST Hybrid Plug 180 Hybrid Plug 180 Hybrid Plug angled Hybrid Plug angled Product description Acceptability for application ECOFAST Hanbrid connector with pin insert For connection to ECOFAST hybrid cables, transmission of data and power ECOFAST Hanbrid connector with socket insert For connection to ECOFAST hybrid cables, transmission of data and power ECOFAST Hanbrid connector with pin insert, angled For connection to ECOFAST hybrid cables, transmission of data and power ECOFAST Hanbrid connector with socket insert, angled For connection to ECOFAST hybrid cables, transmission of data and power Transmission rate Transfer rate with PROFIBUS 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s Interfaces Number of electrical connections for PROFIBUS cables for network components and terminal equipment Design of electrical connection for PROFIBUS cables for network components and terminal equipment Mechanical data Integrated crimp contacts for 6-core ECOFAST hybrid cables Hanbrid connector with male insert Integrated crimp contacts for 6-core ECOFAST hybrid cables Hanbrid connector with female insert Integrated crimp contacts for 6-core ECOFAST hybrid cables Hanbrid connector with male insert Integrated crimp contacts for 6-core ECOFAST hybrid cables Hanbrid connector with female insert Material of the enclosure plastic plastic plastic plastic Design, dimensions and weight Type of cable outlet 180 degree cable outlet 180 degree cable outlet 90 degree cable outlet 90 degree cable outlet Width 7 mm 7 mm 7 mm 7 mm Height 7 mm 7 mm 7 mm 7 mm Depth 71 mm 71 mm 71 mm 71 mm Net weight 40 g 40 g 40 g 40 g Permitted ambient conditions Ambient temperature during operating C C C C during storage C C C C during transport C C C C Protection class IP IP65/67 IP65/67 IP65/67 IP65/67 Chemical resistance to water resistant resistant resistant resistant Product properties, functions, components general Product feature silicon-free Yes Yes Yes Yes Product component strain relief Yes Yes Yes Yes Standards, specifications, approvals Verification of suitability RoHS conformity Yes Yes Yes Yes 3 Siemens IK PI 015 3/37

187 3 PROFIBUS Electrical networks (RS485) ECOFAST bus cables Technical specifications (continued) Article No. 6GK1905-0DA10 Product-type designation PB ECOFAST Terminating Plug Product description ECOFAST bus terminating plug connector with pin insert and integral terminating resistors Acceptability for application As terminating plug-in connector for PROFIBUS DP Transmission rate Transfer rate with PROFIBUS 9.6 kbit/s 1 Mbit/s Interfaces Number of electrical connections for PROFIBUS cables - for network components and 1 terminal equipment Design of electrical connection for PROFIBUS cables - for network components and Hanbrid connector with female insert terminal equipment Number of optical interfaces for - optical waveguide Design of optical connections - for network components or terminal devices Mechanical data Design of terminating resistor Material of the enclosure Integrated resistor combination plastic Article No. 6GK1905-0DA10 Product-type designation PB ECOFAST Terminating Plug Design, dimensions and weight Type of cable outlet 180 degree cable outlet Width 7 mm Height 7 mm Depth 71 mm Net weight 40 g Permitted ambient conditions Ambient temperature during operating C during storage C during transport C Relative humidity at 5 C - without condensation during operating maximum Protection class IP Chemical resistance to water Product properties, functions, components general Product feature silicon-free Product component strain relief Standards, specifications, approvals Verification of suitability RoHS conformity IP65/67 resistant Yes Yes Yes 3/38 Siemens IK PI 015

188 Ordering data Article No. Article No. PROFIBUS Electrical networks (RS485) ECOFAST bus cables PROFIBUS ECOFAST Hybrid Cable - Cu Trailing cable (PUR sheath), with two shielded Cu wires for PROFIBUS DP plus four Cu wires of 1.5 mm Sold by the meter; max. length m, minimum order 0 m 6XV1830-7AH10 Pre-assembled with ECOFAST male and female connectors, fixed length 0.5 m 6XV1830-7BH m 6XV1830-7BH m 6XV1830-7BH15 3 m 6XV1830-7BH30 5 m 6XV1830-7BH50 10 m 6XV1830-7BN10 15 m 6XV1830-7BN15 0 m 6XV1830-7BN0 Pre-assembled with two ECOFAST connectors, variable length PROFIBUS ECOFAST Hybrid Cable GP Trailing cable with 4 x Cu and x Cu, shielded, with UL approval Sold by the meter; 6XV1860-P max. quantity m; minimum order 0 m; Pre-assembled with ECOFAST male and female connectors 0.5 m 6XV1860-3PH05 1 m 6XV1860-3PH m 6XV1860-3PH15 3 m 6XV1860-3PH30 5 m 6XV1860-3PH50 10 m 6XV1860-3PN10 15 m 6XV1860-3PN15 0 m 6XV1860-3PN0 Additional components PROFIBUS Cu bus connector with x Cu shielded and 4 x Cu 1.5 mm ; type of contact: POF, Han D for 4 V; tool: crimping tool, polishing set; 5 units; with assembly instructions with pin insert with socket insert PROFIBUS ECOFAST Hybrid Plug angled; with x Cu shielded and 4xCu 1.5mm ; 5 units; with installation instructions Male pins Female pins; ECOFAST Terminating Plug Bus termination plug-in connector for PROFIBUS DP; with x Cu and 4 x Cu 1.5 mm ; male pins, integrated termination resistors Pack of 1 Pack of 5 Data T piece For x 4 V auxiliary voltage (switched and non-switched) and PROFIBUS DP for Cu RS485 for fiber-optic cable Addressing plug For setting the PROFIBUS DP addresses 6GK1905-0CA00 6GK1905-0CB00 6GK1905-0CC00 6GK1905-0CD00 6GK1905-0DA10 6GK1905-0DA00 3RK1911-AG00 3RK1911-AH00 6ES7194-1KB00-0XA0 3 More information You can order components supplementary to the SIMATIC NET cabling range from your local contact. Technical advice on this subject is available from: J. Hertlein I IA SC CI PRM 4 Phone: +49 (911) [email protected] Siemens IK PI 015 3/39

189 3 PROFIBUS Electrical networks (RS485) Hybrid fieldbus connections Overview Hybrid fieldbus connection with two HanBrid sockets Control cabinet bushing with two M1 sockets Hybrid fieldbus connections with HanBrid sockets designed as cabinet bushings transmit data and energy from the control cabinet (IP0) to the field (IP65). They are the interface for jointly routing PROFIBUS DP and the auxiliary voltages into the hybrid fieldbus cable. On the cabinet bushings with two M1 sockets for the PROFIBUS M1 connecting cables, the 4 V supply of the motor starters is implemented via separate 7/8" connecting cables. Passive and active hybrid fieldbus connections The hybrid fieldbus connections are available in two versions which differ in their functionality. These are: The passive version The active version with signal refresher function to considerably increase the maximum PROFIBUS cable length Connection methods The field side is connected using HanBrid or M1 plug-in connectors. In the case of HanBrid, the following versions are available: Socket/socket for infeeding into the field Pin/socket for looping in the field The M1 version is generally configured with socket/socket. Following connections are available at the rear (cabinet side) in the case of the passive glands: Direct connection Fast Connect connection The active gland with refresher function has 9-pole Sub-D sockets for the rear connection. Auxiliary power infeed The HanBrid plug-in design offers the possibility of infeeding or looping through not only the Profibus signal but also separate auxiliary voltages of 4 V DC (switched/unswitched) into the field. The terminal block with spring-type terminals at the rear (cabinet side) of the hybrid fieldbus connection provides a variety of interconnecting operations for these auxiliary voltages. Passive hybrid fieldbus connections Gland from the control cabinet (IP0) into the field (IP65) HanBrid plug-in design socket/socket or pin/socket Direct connection or Fast-Connect connection for PROFIBUS at the rear Terminal block with spring-type terminals (0.5.5 mm ) for infeeding or looping through the auxiliary voltages IP0 IP65 Pin or socket Socket Hybrid fieldbus connection as passive cabinet bushing 3/40 Siemens IK PI 015

190 PROFIBUS Electrical networks (RS485) Hybrid fieldbus connections Overview (continued) Active hybrid fieldbus connections with refresher function Gland from the control cabinet (IP0) into the field (IP65) 3 independent, electrically separated Profibus segments Signal refresher function from and to all segments Automatic continuous baud rate detection Status/diagnostics displays with LEDs Cascading depth of a maximum 9 hybrid fieldbus connections HanBrid plug-in design socket/socket and pin/socket M1 plug-in design socket/socket 9-pole Sub D socket connection for PROFIBUS at the rear Terminal block with spring-type terminals (0.5.5 mm ) for infeeding or looping through the auxiliary voltages Pin or socket IP0 Refresher IP65 Socket 3 Hybrid fieldbus connection as active control cabinet bushing with refresher function Selection and ordering data Hybrid fieldbus connection on the field side: With socket/socket (HanBrid) With pin/socket (HanBrid) Link type / function Connection IP65 Connection IP0 (PROFIBUS) Article No. Hybrid fieldbus connections Passive Cu/Cu, for feeding into the field Socket/socket ( x HanBrid) Direct connection 3RK1911-1AA Cu/Cu, for looping through in the field Pin/socket ( x HanBrid) Direct connection 3RK1911-1AA3 Cu/Cu, for feeding into the field Socket/socket ( x HanBrid) PROFIBUS Fast Connect bus 3RK1911-1AF connector Cu/Cu, for looping through in the field Pin/socket ( x HanBrid) PROFIBUS Fast Connect bus 3RK1911-1AF3 connector Active (refresher) Cu/Cu, for feeding into the field Socket/socket ( x HanBrid) 9-pole Sub-D socket 3RK1911-1AJ Cu/Cu, for looping through in the field Pin/socket ( x HanBrid) 9-pole Sub-D socket 3RK1911-1AJ3 Cu/Cu, for feeding into the field Socket/socket ( x M1) 9-pole Sub-D socket 3RK1911-1AK Control cabinet bushing on the field side: With socket/socket (M1) Accessories Version Sealing caps for HanBrid Protective cover for bus and power supply connections (pack of 10) Article No. 6ES7194-1JB10-0XA0 6ES7194-1JB10-0XA0 Siemens IK PI 015 3/41

191 3 PROFIBUS Electrical networks (RS485) Energy cables Overview Application Different cable types are needed to supply power to Industrial Ethernet/PROFINET or PROFIBUS. The listed power cables should always be used. They are used for devices with IP65/67 degree of protection to connect the signaling contact or 4-V supply of the SCALANCE X and SCALANCE W components (power cable x0.75) and for the power supply (power cable 5x1.5 for ET 00). In addition, preassembled power connecting cables (4 x 0.75) are available in different lengths for the power supply of the ET 00 (M1 Power Connecting Cable). UL approvals As a result of appropriate UL styles, the cables can be used worldwide. Different versions (5-core, -core) for different fields of application Pre-assembled M1 plug-in cables for energy transfer Rugged cable design for installation in industrial applications UL approvals Easy length measurement thanks to printed meter markings Benefits Flexible application possibilities thanks to rugged cable design Silicon-free, therefore particularly suitable for use in the automotive industry (e.g. on paint shop conveyors) Design Rugged -core, 4-core or 5-core cable with circular crosssection for connection of signaling contact and power supply to IP65/67 components in industrial areas. Cable types The following cables with industrial capability are available for connection of the power supply and signaling contact: Power cable x 0.75; power cable for connection of signaling contact and 4 V supply voltage to SCALANCE X and SCALANCE W components Power cable 5 x 1.5; power cable for connection of 4 V power supply of ET 00 using 7/8" plug connectors M1 Power Connecting Cable M1-180/M1-180; 4-core M1 power connecting cables (A-coded) with straight cable outlet for 4 V power supply of the ET 00 (pre-assembled) 3/4 Siemens IK PI 015

192 PROFIBUS Electrical networks (RS485) Energy cables Technical specifications Article No. 6XV181-8A 6XV1830-8AH10 Product-type designation Energy Cable x 0,75 Energy Cable 5 x 1,5 Product description Energy cable (-core), sold by the meter, in bulk Energy cable (5-core), sold by the meter, in bulk Acceptability for application Connection of signaling contact and 4 V power supply to Power supply of ET 00 modules with 7/8" power port SCALANCE X and SCALANCE W Cable designation L-YY-x1x0.75 GR L-Y11Y-Z 5x1x1.5 GR Electrical data Operating voltage RMS value 600 V 600 V Conductor cross section of the power wires 0.75 mm² 1.5 mm² Continuous current of the power wires 6A 16 A Mechanical data Number of electrical wires 5 Design of the electrical connection - No FastConnect Outer diameter of the inner conductor 1.3 mm 1.55 mm of the wire insulation.5 mm.73 mm of the cable sheath 7.4 mm 10.5 mm Symmetrical tolerance of outer 0.3 mm 0.3 mm diameter of cable sheath Material of the wire insulation PVC PVC of the cable sheath PVC PUR Color of the power wire insulation Brown/blue 4x black, 1x green / yellow of the cable sheath gray gray Bending radius with single bend minimum 19 mm 7 mm permissible with multiple bends minimum permissible 45 mm 63 mm with continuous bending - 75 mm Number of bending cycles Note - For use in cable carriers, for 5 million bending cycles with a bending radius of 75 mm, an acceleration of 4 m/s² and a speed of 180 m/min Traction stress maximum 100 N 500 N Weight per length 70 kg/km 149 kg/km Permitted ambient conditions Ambient temperature during operating C C during storage C C during transport C C during installation C C Burning behaviour flame resistant according to IEC flame resistant according to IEC Chemical resistance to mineral oil Conditional resistance Resistant to grease Conditional resistance Resistant to water Conditional resistance Conditional resistance Radiological resistance to UV radiation Resistant Resistant Product properties, functions, components general Product feature halogen-free No No silicon-free Yes Yes Standards, specifications, approvals UL/ETL listing with 300 V rating Yes: CL3 No UL/ETL style with 600 V rating Yes Yes Verification of suitability CE mark Yes Yes RoHS conformity Yes Yes 3 Siemens IK PI 015 3/43

193 3 PROFIBUS Electrical networks (RS485) Energy cables Technical specifications (continued) Article No. 6XV1801-5DH10 Product-type designation POWER CONNECTING CABLE M1-180/M1-180 Product description Flexible connecting cable (4-core), preferred length, preassembled with a 4-pin M1 plug and a 4-pin M1 socket (A-coded) Acceptability for application Cable for connecting the 4 V power supply to ET 00eco PN to IP 65/67 degree of protection Cable designation LI9YH-Y 4x0.75 Cable length 1m Electrical data Operating voltage RMS value 300 V Conductor cross section of the 0.75 mm² power wires Continuous current of the power wires - Mechanical data Number of electrical wires 4 Outer diameter of the inner conductor 1.1 mm of the wire insulation 1.7 mm of the cable sheath 5.7 mm Symmetrical tolerance of outer 0. mm diameter of cable sheath Material of the wire insulation PP of the cable sheath PVC Color of the power wire insulation Brown / white / blue / black of the cable sheath gray Bending radius with single bend minimum 57 mm permissible with multiple bends minimum 57 mm permissible Traction stress maximum 15 N Weight per length 54 kg/km Article No. 6XV1801-5DH10 Product-type designation POWER CONNECTING CABLE M1-180/M1-180 Permitted ambient conditions Ambient temperature during operating C during storage C during transport C during installation C Comment With moving applications, the permissible operating temperature range is -5 to +80 degrees Celsius Protection class IP IP65/67 Burning behaviour Flame-retardant in accordance with UL 758 (CSA FT 1) Chemical resistance to mineral oil Conditional resistance to grease Conditional resistance to water Conditional resistance Radiological resistance to Not resistant UV radiation Product properties, functions, components general Product feature halogen-free silicon-free Standards, specifications, approvals Verification of suitability UL-registration RoHS conformity No Yes Yes Yes Article No. 6GK1905-0FA00 6GK1905-0FB00 6GK1905-0FC00 Product-type designation 7/8-inch connector 7/8-inch connector 7/8-inch Power T-Tap PRO Product description 7/8" connector with pin insert, 5-pin 7/8" connector with female contact insert, 5-pin Energy T-piece with two 7/8" female contact inserts and one 7/8" pin insert, each 5-pin Acceptability for application For field assembly with ET00 For field assembly with ET00 For power connection and distribution to ET00pro modules Interfaces Number of electrical connections for network components and terminal equipment Design of electrical connection for network components and terminal equipment Mechanical data 7/8 inch plug (male insert) 7/8 inch plug (female insert) 7/8 inch plug ( x female insert, 1 x male insert) Material of the enclosure metal metal metal Design, dimensions and weight Type of cable outlet 180 degree cable outlet 180 degree cable outlet - Width 7 mm 7 mm 58.5 mm Height 7 mm 7 mm 73.5 mm Depth 83 mm 83 mm 6.5 mm Net weight 50 g 50 g 11 g 3/44 Siemens IK PI 015

194 PROFIBUS Electrical networks (RS485) Energy cables Technical specifications (continued) Article No. 6GK1905-0FA00 6GK1905-0FB00 6GK1905-0FC00 Product-type designation 7/8-inch connector 7/8-inch connector 7/8-inch Power T-Tap PRO Permitted ambient conditions Ambient temperature during operating C C C during storage C C C during transport C C C Relative humidity at 5 C without condensation during operating maximum Protection class IP IP65/67 IP65/67 IP65/67 Chemical resistance to water resistant resistant resistant Product properties, functions, components general Product feature silicon-free Yes Yes Yes Product component strain relief Yes Yes Yes Standards, specifications, approvals Verification of suitability RoHS conformity Yes Yes Yes 3 Article No. 6GK1908-0DC10-6AA3 6GK1907-0DC10-6AA3 6GK1907-0DB10-6AA3 Product-type designation Signalling Contact M1 Power M1 Cable Connector PRO Power M1 Plug PRO Cable Connector Product description M1 connecting socket for signal contact, 5-pin, B-coded M1 Power connecting socket, 4-pin, A-coded M1 Power connector, 4-pin, A-coded Acceptability for application Interfaces Number of electrical connections for network components and terminal equipment Design of electrical connection for network components and terminal equipment Mechanical data For connection to SCALANCE X08PRO for signaling contact For connection to SCALANCE W-700 / X08PRO for 4 V DC voltage supply M1 connector (B-coded, 5-pin) M1 connector (female insert, A-coded, 4-pin) For connection to PS791-1PRO power supply for 4 V DC voltage supply M1 connector (male insert, A-coded, 4-pin) Material of the enclosure plastic plastic plastic Design, dimensions and weight Type of cable outlet 180 degree cable outlet 180 degree cable outlet 180 degree cable outlet Width 14 mm 19 mm 19 mm Height 14 mm 19 mm 19 mm Depth 59 mm 73 mm 73 mm Net weight 37 g 40 g 40 g Permitted ambient conditions Ambient temperature during operating C C C during storage C C C during transport C C C Protection class IP IP65/67 IP65/67 IP65/67 Chemical resistance to water resistant resistant resistant Product properties, functions, components general Product feature silicon-free Yes Yes Yes Product component strain relief Yes Yes Yes Standards, specifications, approvals Verification of suitability RoHS conformity Yes Yes Yes Siemens IK PI 015 3/45

195 PROFIBUS Electrical networks (RS485) Energy cables 3 Ordering data Article No. More information Power cable x XV181-8A Power cable with trailing capability with copper cores (0.75 mm ) for connecting to M1 plug-in connector; sold by the meter; max m, minimum order quantity 0 m Power cable 5 x 1.5 6XV1830-8AH10 Power cable with trailing capability with 5 copper cores (1.5 mm ) for connecting to 7/8" plug-in connector; sold by the meter; max m; minimum order quantity 0 m M1 Power Connecting Cable M1-180/M1-180 Flexible 4-core power connecting cable, assembled with A-coded 5-pin M1 connector and A-coded, 5-pin M1 socket to supply the ET 00 with 4 V DC; length: 0.3 m 6XV1801-5DE m 6XV1801-5DE m 6XV1801-5DH m 6XV1801-5DH15.0 m 6XV1801-5DH0 3.0 m 6XV1801-5DH m 6XV1801-5DH50 10 m 6XV1801-5DN10 15 m 6XV1801-5DN15 Additional components 7/8" plug-in connector Plug with axial cable outlet for field assembly for ET 00, 5-core, plastic enclosure, 1 pack = 5 items Male pins 6GK1905-0FA00 Socket insert 6GK1905-0FB00 7/8" Power T-Tap PRO 6GK1905-0FC00 Power T-piece for ET 00 with two 7/8" socket inserts and one 7/8" pin insert 1 pack = 5 items Signaling Contact M1 6GK1908-0DC10-6AA3 Cable Connector PRO Socket for connection of SCALANCE X08PRO for signaling contact; 5-pole, B-coded, with assembly instructions; 3 items Power M1 Cable Connector PRO 6GK1907-0DC10-6AA3 Socket for connection of SCALANCE W-700 for 4 V DC supply voltage; 4-pole, A-coded, with assembly instructions, 3 items Power M1 Plug PRO 6GK1907-0DB10-6AA3 Plug for connection to PS791-1PRO power supply for 4 V DC supply voltage; 4-pole, A-coded, with assembly instructions, 3 items SIMATIC NET Manual Collection 6GK1975-1AA00-3AA0 Electronic manuals for communication systems, communication protocols, and communication products; on DVD, German/English Cable routing: During storage, transport and cable laying, keep both ends sealed with a shrink-on cap. Comply with the permissible bending radii and tensile load! Note: You can order components supplementary to the SIMATIC NET cabling range from your local contact. Technical advice on this subject is available from: J. Hertlein I IA SC CI PRM 4 Phone: +49 (911) [email protected] 3/46 Siemens IK PI 015

196 PROFIBUS Electrical networks (RS485) RS485 bus connector Overview Used for connecting PROFIBUS nodes to the PROFIBUS bus cable Easy installation FastConnect plugs ensure extremely short assembly times due to their insulation-displacement technology Integrated terminating resistors (not in the case of 6ES797-0BA30-0XA0) Connectors with Sub-D socket permit PG connection without the additional installation of network nodes Application The RS485 bus connectors for PROFIBUS are used for connecting a PROFIBUS node or a PROFIBUS network component to the bus cable for PROFIBUS. Design Several different versions of the bus connector are available, each optimized for the devices to be connected: Bus connector with axial cable outlet (180 ), e.g. for PCs and SIMATIC HMI OPs, for transmission rates up to 1 Mbit/s with integrated bus terminating resistor. Bus connector with vertical cable outlet (90 ); This connector permits a vertical cable outlet (with or without PG interface) for transmission rates of up to 1 Mbit/s with integral bus terminating resistor. At a transmission rate of 3, 6 or 1 Mbit/s, the SIMATIC S5/S7 plug-in cable is required for the connection between bus connector with PG-interface and programming device. Bus connector with 30 cable outlet (low-cost version) without PG interface for transmission rates of up to 1.5 Mbit/s and without integrated bus terminating resistor. PROFIBUS FastConnect bus connector RS485 (90 or 180 cable outlet) with transmission rates up to 1 Mbit/s for fast and easy assembly using insulation displacement connection technology (for rigid and flexible wires). Function The bus connector is plugged directly into the PROFIBUS interface (9-pin Sub-D socket) of the PROFIBUS station or a PROFIBUS network component. The incoming and outgoing PROFIBUS cable is connected in the plug using 4 terminals. By means of an easily accessible switch which is clearly visible from the outside, the line terminator integrated in the bus connector can be connected (not in the case of 6ES797-0BA30-0XA0). In this process, incoming and outgoing bus cables in the connector are separated (separation function). This must be done at both ends of a PROFIBUS segment. 3 Siemens IK PI 015 3/47

197 PROFIBUS Electrical networks (RS485) RS485 bus connector Technical specifications 3 Article No. Product-type designation Acceptability for application 6ES797-0BA1-0XA0 PROFIBUS bus connector RS 485 without PG interface, 90 For connecting PROFIBUS nodes to the PROFIBUS bus cable 6ES797-0BB1-0XA0 6ES797-0BA4-0XA0 PROFIBUS bus PROFIBUS bus connector RS 485 connector RS 485 with PG interface, 90 without PG interface, 35 For connecting PROFIBUS nodes to the PROFIBUS bus cable For connecting PROFIBUS nodes to the PROFIBUS bus cable 6ES797-0BB4-0XA0 PROFIBUS bus connector RS 485 with PG interface, 35 For connecting PROFIBUS nodes to the PROFIBUS bus cable 6ES797-0BA30-0XA0 PROFIBUS FastConnect bus connector RS485 with PG interface, 30 For connecting PROFIBUS nodes to the PROFIBUS bus cable Transmission rate Transfer rate with PROFIBUS 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6kbit/s 1.5Mbit/s Interfaces Number of electrical connections for PROFIBUS cables for network components and terminal equipment Design of electrical connection for PROFIBUS cables Screw Screw Screw Screw Integrated insulation displacement contacts for -wire PB FC installation cables for network components and terminal equipment 9-pin sub-d socket 9-pin sub-d socket 9-pin sub-d socket 9-pin sub-d socket 9-pin sub-d socket FastConnect No No No Yes Mechanical data Design of terminating resistor Integrated resistor combination, can be connected via slide switch Integrated resistor combination, can be connected via slide switch Integrated resistor combination, can be connected via slide switch Integrated resistor combination, can be connected via slide switch No integrated terminating resistor Material of the enclosure plastic plastic plastic plastic plastic Design, dimensions and weight Type of cable outlet 90 degree cable outlet 90 degree cable outlet Width 15.8 mm 15.8 mm 15.8 mm 15.8 mm 15 mm Height 64 mm 64 mm 54 mm 54 mm 57.6 mm Depth 35.6 mm 35.6 mm 39.5 mm 39.5 mm 39.5 mm Net weight 10 g 10 g 60 g 67 g 46 g Permitted ambient conditions Ambient temperature during operating C C C C C during storage C C C C C during transport C C C C C Relative humidity at 5 C without condensation during operating maximum 95 % 95 % 95 % 95 % Protection class IP IP0 IP0 IP0 IP0 IP0 Product properties, functions, components general Product feature silicon-free Yes Yes Yes Yes Yes Product component PG connection socket No Yes No Yes No strain relief Yes Yes Yes Yes Yes Standards, specifications, approvals Verification of suitability RoHS conformity Yes Yes Yes Yes Yes UL-registration Yes Yes Yes Yes Yes 3/48 Siemens IK PI 015

198 PROFIBUS Electrical networks (RS485) RS485 bus connector Technical specifications (continued) Article No. 6ES797-0BA5-0XA0 6ES797-0BB5-0XA0 6ES797-0BA60-0XA0 6ES797-0BB60-0XA0 Product-type designation PROFIBUS FastConnect bus connector RS485 without PG interface, 90 PROFIBUS FastConnect bus connector RS485 with PG interface, 90 PROFIBUS FastConnect bus connector RS485 without PG interface, 35 PROFIBUS FastConnect bus connector RS485 with PG interface, 35 Acceptability for application For connecting PROFIBUS nodes to the PROFIBUS bus cable For connecting PROFIBUS nodes to the PROFIBUS bus cable For connecting PROFIBUS nodes to the PROFIBUS bus cable For connecting PROFIBUS nodes to the PROFIBUS bus cable Transmission rate Transfer rate with PROFIBUS 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s Interfaces Number of electrical connections for PROFIBUS cables for network components and terminal equipment Design of electrical connection for PROFIBUS cables Integrated insulation displacement contacts for -wire PB FC installation cables Integrated insulation displacement contacts for -wire PB FC installation cables Integrated insulation displacement contacts for -wire PB FC installation cables Integrated insulation displacement contacts for -wire PB FC installation cables for network components and terminal equipment 9-pin sub-d socket 9-pin sub-d socket 9-pin sub-d socket 9-pin sub-d socket FastConnect Yes Yes Yes Yes Mechanical data Integrated resistor combination, can be connected via slide switch Integrated resistor combination, can be connected via slide switch Integrated resistor combination, can be connected via slide switch Integrated resistor combination, can be connected via slide switch Material of the enclosure plastic plastic plastic plastic Design, dimensions and weight Type of cable outlet 90 degree cable outlet 90 degree cable outlet 35 degree cable outlet 35 degree cable outle Width 15.8 mm 15.8 mm 15.8 mm 15.8 mm Height 59 mm 59 mm 54 mm 54 mm Depth 35.6 mm 35.6 mm 39.5 mm 39.5 mm Net weight 10 g 10 g 9 g 34 g Permitted ambient conditions Ambient temperature during operating C C C C during storage C C C C during transport C C C C Relative humidity at 5 C without condensation during operating maximum 95 % 95 % 95 % 95 % Protection class IP IP0 IP0 IP0 IP0 Product properties, functions, components general Product feature silicon-free Yes Yes Yes Yes Product component PG connection socket No Yes No Yes strain relief Yes Yes Yes Yes Standards, specifications, approvals Verification of suitability RoHS conformity Yes Yes Yes Yes UL-registration Yes Yes Yes Yes 3 Siemens IK PI 015 3/49

199 PROFIBUS Electrical networks (RS485) RS485 bus connector Technical specifications (continued) 3 Article No. 6ES797-0BA70-0XA0 6ES797-0BB70-0XA0 6GK1500-0EA0 6GK1500-0FC10 Product-type designation PROFIBUS FastConnect bus connector RS485 without PG interface, 90 PROFIBUS FastConnect bus connector RS485 with PG interface, 90 PROFIBUS bus connector RS 485 PROFIBUS FC bus connector RS 485 Acceptability for application For connecting PROFIBUS nodes to the PROFIBUS bus cable For connecting PROFIBUS nodes to the PROFIBUS bus cable For connecting PROFIBUS nodes to the PROFIBUS bus cable For connecting PROFIBUS nodes to the PROFIBUS bus cable Transmission rate Transfer rate with PROFIBUS 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s Interfaces Number of electrical connections for PROFIBUS cables for network components and terminal equipment Design of electrical connection for PROFIBUS cables Integrated insulation displacement contacts for -wire PB FC installation cables Integrated insulation displacement contacts for -wire PB FC installation cables Terminal blocks Integrated insulation displacement contacts for -core PB FC installation cables for network components and terminal equipment 9-pin Sub-D plug 9-pin Sub-D plug 9-pin Sub-D plug 9-pin Sub-D plug FastConnect Yes Yes No Yes Mechanical data Design of terminating resistor Integrated resistor combination Integrated resistor combina- Integrated resistor combina- Integrated resistor combina- that can be selected with tion that can be selected with tion that can be selected with tion that can be selected with slide switch. Disconnect slide switch. slide switch. Disconnect slide switch. Disconnect function: When the resistor is connected, the outgoing bus function: When the resistor is function: When the resistor is connected, the outgoing bus connected, the outgoing bus is isolated. is isolated. is isolated. Material of the enclosure plastic plastic metal plastic Design, dimensions and weight Type of cable outlet 90 degree cable outlet 90 degree cable outlet 180 degree cable outlet 180 degree cable outlet Width 15.8 mm 15.8 mm 15 mm 16 mm Height 7 mm 7 mm 57 mm 6 mm Depth 36.4 mm 36.4 mm 39 mm 34,5 mm Net weight 34 g 10 g 100 g 40 g Permitted ambient conditions Ambient temperature during operating 0 60 C 0 60 C 0 60 C 0 60 C during storage C C C C during transport C C C C Relative humidity at 5 C without condensation during operating maximum 75 % 75 % 75 % 75 % Protection class IP IP0 IP0 IP0 IP0 Product properties, functions, components general Product feature silicon-free Yes Yes Yes Yes Product component PG connection socket No Yes No No strain relief Yes Yes Yes Yes Standards, specifications, approvals Verification of suitability RoHS conformity Yes Yes Yes Yes UL-registration Yes Yes No Yes 3/50 Siemens IK PI 015

200 Ordering data Article No. Article No. PROFIBUS Electrical networks (RS485) RS485 bus connector RS485 bus connector with axial cable outlet (180 ) For industrial PC, SIMATIC HMI OP, OLM; max. transmission rate 1 Mbit/s SIPLUS DP PB RS485 connector with axial cable outlet (180 ) for medial stress; Based-on 6GK EA0 RS485 bus connector with cable outlet (90 ) With screw-terminals, max. transmission rate 1 Mbit/s Without PG interface With PG interface SIPLUS DP PB RS485 connector with 90 cable outlet for extended temperature range C without PG interface Based on 6ES7 97-0BA1-0XA0 with PG interface Based on 6ES7 97-0BB1-0XA0 RS485 bus connector with angled cable outlet (35 ) With screw-terminals, max. transmission rate 1 Mbit/s Without PG interface With PG interface SIPLUS DP PB RS485 connector with inclined cable outlet (35 ) for extended temperature range C without PG interface Based on 6ES7 94-0BA4-0XA0 with PG interface Based on 6ES7 94-0BB4-0XA0 RS485 bus connector with cable outlet (30 ) With screw-terminals, low-cost variant, max. transmission rate 1.5 Mbit/s 6GK1500-0EA0 6AG1500-0EA0-AA0 6ES797-0BA1-0XA0 6ES797-0BB1-0XA0 6AG197-0BA1-XA0 6AG197-0BB1-XA0 6ES797-0BA4-0XA0 6ES797-0BB4-0XA0 6AG197-0BA4-7XA0 6AG197-0BB4-7XA0 6ES797-0BA30-0XA0 PROFIBUS bus connector RS485 with FastConnect technology PROFIBUS FastConnect bus connector RS485 with 90 cable outlet with insulation displacement, max. transmission rate 1 Mbps Without PG interface 1 unit 6ES797-0BA5-0XA0 100 units 6ES797-0BA5-0XB0 With PG interface 1 unit 6ES797-0BB5-0XA0 100 units 6ES797-0BB5-0XB0 without PG interface, grounding via control cabinet cover 1 unit 6ES797-0BA70-0XA0 with PG interface, grounding via control cabinet cover 1 unit 6ES797-0BB70-0XA0 PROFIBUS FastConnect RS485 bus connector with angled cable outlet (35 ) with insulation displacement, max. transmission rate 1 Mbps Without PG interface 6ES797-0BA60-0XA0 With PG interface 6ES797-0BB60-0XA0 PROFIBUS FastConnect 6GK1500-0FC10 bus connector RS485 Plug 180 with insulation displacement terminals, with 180 cable outlet, for industrial PC, SIMATIC HMI OP, OLM; max. transmission rate 1 Mbit/s SIMATIC S5/S7 plug-in cable for 6ES7901-4BD00-0XA0 PROFIBUS Preassembled with two 9-pin sub-d connectors; max. transmission rate 1 Mbit/s; 3 m SIMATIC NET Manual Collection 6GK1975-1AA00-3AA0 Electronic manuals for communication systems, communication protocols, and communication products; on DVD; German/English 3 Siemens IK PI 015 3/51

201 PROFIBUS Electrical networks (RS485) 830-1T connecting cable Overview Technical specifications 3 Article No. 6XV1830-1CH15 6XV1830-1CH30 Product-type designation Acceptability for application Ordering data connecting cable 830-1T For connecting PROFIBUS nodes to OLM or OBT Cable length 1.5 m 3m Mechanical data Net weight - - Article No. connecting cable 830-1T For connecting PROFIBUS nodes to OLM or OBT Prefabricated cable for fast and cost-effective connection of PROFIBUS nodes to OLM and OBT Flexible PROFIBUS connecting cable 830-1T PROFIBUS connecting cable for terminal connection, preassembled, with two Sub-D plugs, 9-pin terminated at both ends 1.5 m long 6XV1830-1CH15 3 m long 6XV1830-1CH30 Benefits Trouble-free connection of end stations through preassembled connecting leads Reliable data transmission to the end station in EMC-exposed environment through direct cable shielding and termination. Design The 830-1T connecting cable consists of a twisted-pair cable (wires made of stranded copper) with a woven shield. It has a 9-pin Sub-D plug at both ends. Both cable ends are terminated by a resistor combination (cannot be switched off). Function The PROFIBUS 830-1T connecting cable is used for connecting the electrical PROFIBUS interface to the PROFIBUS nodes (OLM, OBT and data terminals) for data transmission rates of up to 1 Mbit/s. 3/5 Siemens IK PI 015

202 PROFIBUS Electrical networks (RS485) 830- connecting cable Overview Benefits Trouble-free connection of end stations through preassembled connecting leads Direct connection of a PG through the PG interface without interrupting the connection between the stations. Design The 830- connecting cable comprises a standard PROFIBUS bus cable. It is preassembled with two 9-pin connectors (6GK EA0 and 6ES7 97-0BB11-0XA0). One plug of the preassembled connecting cable is equipped with a PG interface. 3 Prefabricated cable for connection of PROFIBUS nodes (e.g. HMI) to PLCs Flexible PROFIBUS connection cable for up to 1 Mbit/s Function The 830- connecting cable is used to connect PROFIBUS nodes (e.g. HMI) to automation devices for transmission rates up to 1 Mbit/s. Technical specifications Article No. 6XV1830-AH30 6XV1830-AH50 6XV1830-AN10 Product-type designation PROFIBUS connecting cable 830- PROFIBUS connecting cable 830- PROFIBUS connecting cable 830- Acceptability for application Cable for connecting PROFIBUS stations (e.g. HMI) to automation devices Cable for connecting PROFIBUS stations (e.g. HMI) to automation devices Cable for connecting PROFIBUS stations (e.g. HMI) to automation devices Cable length 3m 5m 10 m Mechanical data Net weight Ordering data Article No PROFIBUS connecting cable Preassembled, with two 9-pin connectors 3 m long 6XV1830-AH30 5 m long 6XV1830-AH50 10 m long 6XV1830-AN10 Siemens IK PI 015 3/53

203 PROFIBUS Electrical networks (RS485) PROFIBUS M1 and 7/8" connecting cable/connector Overview Benefits 3 Flexible connecting cables and FastConnect (FC) plug-in connectors that can be assembled in the field for transmission of data (up to 1 Mbit/s) or for power supply between PROFIBUS nodes with IP65 degree of protection PROFIBUS M1 plug-in cable Preassembled plug-in cable (PROFIBUS FC Trailing Cable) for connecting PROFIBUS nodes (e.g. SIMATIC ET 00) to IP65 degree of protection For transmission rates up to 1 Mbit/s 7/8" connecting cable Preassembled plug-in cable for supplying power to PROFIBUS nodes (e.g. SIMATIC ET 00) to IP65 degree of protection PROFIBUS FC M1 Plug PRO (B-coded) and 7/8" plug-in connector For establishing direct connections between devices on PROFIBUS installation and power cables with M1 or 7/8" connections Excellent EMC shielding and deflection (metal housing) Easy assembly due to integrated FastConnect technology (FC M1 Plug) Viewable contact area prevents errors Time-saving and fault-free connection of terminal stations by means of prefabricated connection cables Easy assembly on site for application-specific M1 and 7/8 plug-in cables by means of FC M1 and 7/8 plug-in connectors that can be assembled in the field Design M1 plug-in cable Comprises the PROFIBUS Trailing Cable Pre-assembled with two 5-pole M1 male/female connectors; B-coded 7/8" plug-in cable Comprises the Energy Cable 5 x 1.5 mm Pre-assembled with two 5-pole 7/8" male/female connectors 3/54 Siemens IK PI 015

204 PROFIBUS Electrical networks (RS485) PROFIBUS M1 and 7/8" connecting cable/connector Technical specifications Article No. Product-type designation Product description Acceptability for application Cable designation Cable length Electrical data Damping ratio per length at 9.6 khz maximum at 38.4 khz maximum at 4 MHz maximum at 16 MHz maximum Impedance Nominal value at 9.6 khz at 38.4 khz for frequency range 3 MHz 0 MHz 6XV1830-3DH10 PROFIBUS M1 connecting cable Flexible connecting cable (-core), preferred length, preassembled with two 5-pin M1 plugs/sockets (B-coded) Cable for connecting PROFIBUS stations (e.g. SIMATIC ET 00) to IP 65 degree of protection 0YY (ST) C11Y 1xx0.65/ LI KF 40 FR petrol 1m db/m db/m 0.05 db/m db/m Relative symmetrical tolerance of the surge impedance at 9.6 khz 10 % of the surge impedance at 38.4 khz 10 % of the surge impedance at 10 % 3 MHz 0 MHz Loop resistance per length 133 /km maximum Shield resistance per length 14 /km maximum Capacity per length at 1 khz 8 pf/m Operating voltage RMS value 100 V Mechanical data Number of electrical wires Design of shield Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Design of the electrical connection Yes FastConnect Outer diameter of the inner conductor 0.67 mm of the wire insulation.56 mm of the inner sheath of the cable 5.4 mm of the cable sheath 8mm Symmetrical tolerance of outer 0.4 mm diameter of cable sheath Outer diameter of the cable sheath - Note Material of the wire insulation PE of the inner sheath of the cable PVC of the cable sheath PUR -Note - Article No. 6XV1830-3DH10 Product-type designation PROFIBUS M1 connecting cable Color of the insulation of data wires red / green of the cable sheath Petrol Bending radius with single bend minimum 40 mm permissible with multiple bends minimum - permissible with continuous bending 10 mm Number of bending cycles Note For use in cable carriers, for 3 million bending cycles with a bending radius of 10 mm (15x D) and an acceleration of 4 m/s² Number of torsion cycles with torsion - by ± 180 on 1 m cable length Traction stress maximum 100 N Weight per length 77 kg/km Permitted ambient conditions Ambient temperature during operating C during storage C during transport C during installation C Ambient condition for (standard) operation mode Protection class IP Burning behaviour Chemical resistance to mineral oil to grease to water Radiological resistance to UV radiation Product properties, functions, components general Product feature halogen-free No silicon-free Yes Cable length at max. 1.5 Mbit/s - at max. 1 Mbit/s - Standards, specifications, approvals UL/ETL listing with 300 V rating Yes: CMX UL/ETL style with 600 V rating No Verification of suitability CE mark - UL-registration - - RoHS conformity Yes Marine classification association Germanische Lloyd (GL) No Lloyds Register of Shipping (LRS) No Limited segment length (see manual for PROFIBUS networks) IP65/67 flame resistant according to IEC oil resistant according to IEC (7x4h/90 C) Resistant Conditional resistance Resistant 3 Siemens IK PI 015 3/55

205 3 PROFIBUS Electrical networks (RS485) PROFIBUS M1 and 7/8" connecting cable/connector Technical specifications (continued) Article No. 6XV18-5BH10 Product-type designation 7/8 connecting cable Product description Connecting cable (5-core), preferred length, preassembled with two 5-pin 7/8" plugs/sockets Acceptability for application Power supply of ET 00 modules with 7/8 inch power port to IP 65 degree of protection Cable designation L-Y11Y-Z 5x1x1.5 GR Cable length 1m Electrical data Operating voltage RMS value 600 V Conductor cross section of the 1.5 mm² power wires Continuous current of the power wires 16 A Mechanical data Number of electrical wires 5 Design of shield - Design of the electrical connection - FastConnect Outer diameter of the inner conductor 1.55 mm of the wire insulation.73 mm of the cable sheath 10.5 mm Symmetrical tolerance of outer 0.3 mm diameter of cable sheath Outer diameter of the cable sheath - Note Material of the wire insulation PVC of the cable sheath PUR -Note - Color of the power wire insulation Black of the cable sheath gray Bending radius with single bend minimum 7 mm permissible with multiple bends minimum 63 mm permissible with continuous bending 75 mm Number of bending cycles Note For use in cable carriers, for 5 million bending cycles with a bending radius of 75 mm, an acceleration of 4 m/s² and a speed of 180 m/min Number of torsion cycles with torsion - by ± 180 on 1 m cable length Traction stress maximum 500 N Weight per length 149 kg/km Article No. 6XV18-5BH10 Product-type designation 7/8 connecting cable Permitted ambient conditions Ambient temperature during operating C during storage C during transport C during installation C Comment - Ambient condition for (standard) - operation mode Protection class IP IP65/67 Burning behaviour Flame-retardant in accordance with IEC Chemical resistance to mineral oil Resistant to grease Resistant to water - Radiological resistance to Resistant UV radiation Product properties, functions, components general Product feature halogen-free No silicon-free Yes Standards, specifications, approvals UL/ETL listing with 300 V rating No UL/ETL style with 600 V rating Yes Verification of suitability CE mark - UL-registration - RoHS conformity Yes 3/56 Siemens IK PI 015

206 PROFIBUS Electrical networks (RS485) PROFIBUS M1 and 7/8" connecting cable/connector Technical specifications (continued) Article No. 6GK1905-0EA10 6GK1905-0EB10 6GK1905-0EA00 6GK1905-0EB00 Product-type designation PB FC M1 Plug PRO PB FC M1 PB M1 connector PB M1 connector Cable Connector PRO Product description M1 connector with male contact insert, 5-pin, B-coded M1 connector with female contact insert, 5-pin, B-coded M1 connector with male contact insert, 5-pin, B-coded M1 connector with female contact insert, 5-pin, B-coded Acceptability for application Transmission rate For connecting electrical PB FC bus cables to ET00 PRO, suitable for fast assembly with the FastConnect system For connecting electrical PB FC bus cables to ET00 PRO, suitable for fast assembly with the FastConnect system For connecting electrical PB bus cables to ET00 For connecting electrical PB bus cables to ET00 Transfer rate with PROFIBUS 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s 9.6 kbit/s 1 Mbit/s Interfaces Number of electrical connections for PROFIBUS cables for network components and terminal equipment Design of electrical connection for PROFIBUS cables Integrated insulation displacement contacts for -core PB FC installation cables M1 connector (male insert, 4-pin, B-coded) Integrated insulation displacement contacts for -core PB FC installation cables Integrated screw-type contacts for -core PB installation cables Integrated screw-type contacts for -core PB installation cables for network components and terminal equipment M1 connector (female insert, 5-pin, B-coded) M1 connector (male insert, 4-pin, B-coded) M1 connector (female insert, 5-pin, B-coded) FastConnect Yes Yes No No Mechanical data Design of terminating resistor Material of the enclosure metal metal metal metal Design, dimensions and weight Type of cable outlet 180 degree cable outlet 180 degree cable outlet 180 degree cable outlet 180 degree cable outlet Width 19 mm 19 mm 19 mm 19 mm Height 19 mm 19 mm 19 mm 19 mm Depth 73 mm 73 mm 73 mm 73 mm Net weight 40 g 40 g 40 g 40 g Permitted ambient conditions Ambient temperature during operating C C C C during storage C C C C during transport C C C C Relative humidity at 5 C without condensation during operating maximum Protection class IP IP65/67 IP65/67 IP65/67 IP65/67 Chemical resistance to water resistant resistant resistant resistant Product properties, functions, components general Product feature silicon-free Yes Yes Yes Yes Product component PG connection socket Product component strain relief Yes Yes Yes Yes Standards, specifications, approvals Verification of suitability RoHS conformity Yes Yes Yes Yes UL-registration Yes Yes No No 3 Siemens IK PI 015 3/57

207 PROFIBUS Electrical networks (RS485) PROFIBUS M1 and 7/8" connecting cable/connector Technical specifications (continued) 3 Article No. 6GK1905-0FA00 6GK1905-0FB00 Product-type designation 7/8-inch connector 7/8-inch connector Product description 7/8" connector with pin insert, 5-pin 7/8" connector with female contact insert, 5-pin Acceptability for application For field assembly with ET00 For field assembly with ET00 Transmission rate Transfer rate with PROFIBUS - - Interfaces Number of electrical connections for 1 1 network components and terminal equipment Design of electrical connection for network components and terminal equipment 7/8 inch plug (male insert) 7/8 inch plug (female insert) Mechanical data Material of the enclosure metal metal Design, dimensions and weight Type of cable outlet 180 degree cable outlet 180 degree cable outlet Width 7 mm 7 mm Height 7 mm 7 mm Depth 83 mm 83 mm Net weight 50 g 50 g Permitted ambient conditions Ambient temperature during operating C C during storage C C during transport C C Relative humidity at 5 C without condensation during operating maximum - - Protection class IP IP65/67 IP65/67 Chemical resistance to water resistant resistant Product properties, functions, components general Product feature silicon-free Yes Yes Product component strain relief Yes Yes Standards, specifications, approvals Verification of suitability RoHS conformity Yes Yes 3/58 Siemens IK PI 015

208 PROFIBUS Electrical networks (RS485) PROFIBUS M1 and 7/8" connecting cable/connector Ordering data Article No. Article No. PROFIBUS M1 plug-in cable Plug-in connector for assembly in the field Pre-assembled with two 5-pole M1 male/female connectors up to 100 m max.; length: 0.3 m 0.5 m 1.0 m 1.5 m.0 m 3.0 m 5.0 m 10 m 15 m Further special lengths with 90 or 180 cable outlet 7/8" plug-in cable For power supply; pre-assembled with two 5-pole 7/8" male/female connectors up to 50 m max.; length: 0.3 m 0.5 m 1.0 m 1.5 m.0 m 3.0 m 5.0 m 10 m 15 m Additional special lengths with 90 or 180 cable outlet 6XV1830-3DE30 6XV1830-3DE50 6XV1830-3DH10 6XV1830-3DH15 6XV1830-3DH0 6Xv1830-3DH30 6XV1830-3DH50 6XV1830-3DN10 6XV1830-3DN15 See 6XV18-5BE30 6XV18-5BE50 6XV18-5BH10 6XV18-5BH15 6XV18-5BH0 6XV18-5BH30 6XV18-5BH50 6XV18-5BN10 6XV18-5BN15 See PROFIBUS M1 connectors 5-pole, B-coded, metal casing, 1 pack = 5 items Male pins Socket insert PROFIBUS FC M1 Plug PRO M1 plug-in connector (B-coded) that can be assembled in the field, 5-pin, metal enclosure, FastConnect technology, pin insert; 1 pack = 5 items PROFIBUS FC M1 Cable Connector PRO M1 plug-in connector (B-coded) that can be assembled in the field, 5-pin, metal enclosure, FastConnect technology, socket insert; 1 pack = 5 items 7/8" plug-in connector 5-pole, plastic casing, 1 pack = 5 items Male pins Socket insert Power cables Energy Cable (5 x 1.5 mm ) Power cable with trailing capability with 5 copper cores (1.5 mm ) for connecting to 7/8" plug-in connector; sold by the meter; max m; minimum order quantity 0 m 6GK1905-0EA00 6GK1905-0EB00 6GK1905-0EA10 6GK1905-0EB10 6GK1905-0FA00 6GK1905-0FB00 6XV1830-8AH10 3 7/8" Power T-Tap PRO 6GK1905-0FC00 Power T-piece for ET 00 with two 7/8" socket inserts and one 7/8" pin insert 1 pack = 5 items Siemens IK PI 015 3/59

209 PROFIBUS Electrical networks (RS485) PROFIBUS M1 and 7/8" connecting cable/connector Dimensional drawings 5 1 7/8-16UN-A Ø 6 mm mm mm ,8 mm 17,5 mm /8-16UN-B Ø 6 mm G_IK10_XX_5003 7/8 Power T-Tap PRO More information Special lengths with 90 or 180 cable outlet You can find more information on the Internet at: 3/60 Siemens IK PI 015

210 PROFIBUS Electrical networks (RS485) Bus terminals Overview For connecting PROFIBUS nodes with an RS485 interface to a segment Versions with transmission rates from 9.6 kbit/s to 1 Mbit/s Clear and easy mounting (can be snapped onto DIN rail) Clear location of faulty bus termination when bus terminal 1M is used PG connection with special bus terminal and PG connecting cable possible without additional installation of network nodes for bus terminal RS485. Benefits Easy and clearly comprehensible connection of PROFIBUS stations thanks to preassembled, integrated connecting cable Simple cabinet pre-wiring by connecting the PROFIBUS connecting cable with integrated interfaces Application The PROFIBUS bus terminals enable a bus station to be connected to a PROFIBUS network. Pre-wired device connection for PROFIBUS node Easy connection of stations to PROFIBUS networks through insertion of the radial line with Sub-D plug Implementation of multipoint connections by directly interconnecting several bus terminals (up to 3 stations per segment) with the 1M bus terminal. Design Different versions are available: Up to 1.5 Mbit/s Bus terminal RS485 Up to 1 Mbit/s Bus terminal 1M Applicable to all versions: IP0 enclosure. Wall mounting or mounting on deep standard DIN rail possible. External 6-pin terminal block for connection of inoming and outgoing bus cable and equipotential bonding conductors. Integrated connecting cable with Sub-D plug for connection of nodes. Combination of terminating resistors can be connected by means of rotary switch. The following additionally applies to the bus terminal 1M: Ranges for transmission rates can be adjusted by means of rotary switches. Supply to the bus terminal 1M by the connected PROFIBUS node (5 V DC/90 ma) via 9-pin Sub-D socket. For maximum segment lengths, see Technical Specifications. Incoming and outgoing bus cables are disconnected when inserting the terminating resistors. 3 Siemens IK PI 015 3/61

211 PROFIBUS Electrical networks (RS485) Bus terminals Function Connection of stations by means of integrated connecting cable with Sub-D plug. Easy connection of the bus cable by means of terminal block No interruption of bus if an end user station is missing Bus termination is possible by means of an integrated combination of terminating resistors. The following additionally applies to the bus terminal 1M: Clear location of faulty termination within a segment (incoming and outgoing bus cables are separated when inserting the resistor combination) If the bus terminal 1M is used in a segment with RS485 bus terminals, the configuration rules of the RS485 bus terminal apply (see Manual for PROFIBUS Networks). 3 e.g. SIMATIC S7-300 with communications processor Bus terminal PROFIBUS G_IK10_XX_5000 System connection with PROFIBUS bus terminals, e.g. for SIMATIC S7 3/6 Siemens IK PI 015

212 PROFIBUS Electrical networks (RS485) Bus terminals Technical specifications Article No. 6GK1500-0AA10 6GK1500-0AB00 6GK1500-0DA00 Product-type designation PROFIBUS bus terminal 1M Bus terminal RS 485 (3m) Bus terminal RS 485 (1.5 m) Electrical data Transfer rate with PROFIBUS minimum 9.6 kbit/s 9.6 kbit/s 9.6 kbit/s maximum 1 Mbit/s 1.5 Mbit/s 1.5 Mbit/s Interfaces Number of electrical connectrtions for PROFIBUS cables Mechanical data Material of the enclosure plastic plastic plastic Design, dimensions and weight Width 50 mm 50 mm 50 mm Height 138 mm 138 mm 138 mm Depth 53 mm 53 mm 53 mm Net weight 360 g 360 g 360 g Mounting type 35 mm DIN rail Yes Yes Yes mounting Standards, specifications, approvals Verification of suitability UL-registration Yes Ordering data Article No. Article No. Bus terminal RS485 for PROFIBUS Transmission rate 9.6 Kbit/s to Kbit/s with plug-in cable 3.0 m long Bus terminal RS485 for PROFIBUS With installed programmer port and plug-in cable 1.5 m long 6GK1500-0AB00 6GK1500-0DA00 PROFIBUS bus terminal 1M Bus terminal for connection of PROFIBUS stations up to 1 Mbit/s with plug-in cable 1.5 m long SIMATIC NET Manual Collection Electronic manuals for communication systems, communication protocols, and communication products; on DVD; German/English 6GK1500-0AA10 6GK1975-1AA00-3AA0 Siemens IK PI 015 3/63

213 PROFIBUS Electrical networks (RS485) Active RS 485 terminating element 3 Overview Terminates bus segments at data transmission rates of 9.6 kbit/s to 1 Mbit/s Power supply independent of bus stations. Designed for Industry Terminal-independent bus termination through onboard power supply Application The active RS 485 terminating resistance is used to terminate bus segments. Power supply is independent of the stations. The terminating resistor is supplied with power separately from the other I/O components, either permanently or with a voltage applied ahead of the I/Os. By terminating the bus system the stations (e.g. ET 00S) can be coupled and decoupled selectively without malfunctions. Design 1 terminal block for the segment connection Terminal block for power supply (4 V DC external) Function The active RS 485 terminating element terminates the PROFIBUS and therefore ensures a defined level of the RS 485 signal and suppression of reflections on the line. Since it is operated independently of the field devices, they can be decoupled from the bus without reactions. Technical specifications 6ES797-0DA00-0AA0 Supply voltage 4 V DC Yes permissible range, lower limit (DC) 0.4 V permissible range, upper limit (DC) 8.8 V Input current Current consumption, typ. 30 ma Interfaces Bus cables Screw terminal block PROFIBUS DP Transmission rate, max. 1 Mbit/s; 9.6 kbit/s to 1 Mbit/s Degree and class of protection IP0 Yes Ambient conditions Operating temperature Min. 0 C max. 60 C Storage/transport temperature Min. -40 C max. 70 C Relative humidity max. relative humidity 95 %; at +5 C Connection method Power supply Screw terminal block Dimensions Width 60 mm Height 70 mm Depth 43 mm Weights Weight, approx. 95 g Ordering data Active RS 485 terminating element for PROFIBUS to complete bus segments for transmission rates of 9.6 kbit/s to 1 Mbit/s Article No. 6ES797-0DA00-0AA0 More information Brochures Information material for downloading can be found in the Internet: 3/64 Siemens IK PI 015

214 PROFIBUS Electrical networks (RS485) Repeater RS 485 for PROFIBUS Overview Application The RS 485 IP0 repeater connects two PROFIBUS or MPI bus segments using the RS 485 system with up to 3 stations. Data transmission rates of 9.6 kbit/s to 1 Mbit/s are then possible. Automatic detection of transmission rates Transmission rates from 9.6 kbit/s to 1 Mbit/s are possible, incl kbit/s 4 V DC voltage display Indication of bus activity segment 1 and The separation of segment 1 and segment by means of switches is possible Separation of the right segment with an inserted terminating resistor Decoupling of segment 1 and segment in the case of static interference Designed for Industry For increasing the expansion Electric isolation of segments Commissioning support - Switches for separation of segments - Bus activity display - Segment separation in the case of an incorrectly inserted terminating resistor In this context, please also note the diagnostics repeater that provides extensive diagnostics functions for physical line diagnostics in addition to the normal repeater functionality. This is described in "Distributed I/O / diagnostics / diagnostics repeater for PROFIBUS DP". Design Housing to degree of protection IP0. terminal blocks for connecting the segment Terminal block for supply voltage (4 V DC external). PG/OP interface. Function Mode of operation Increasing the number of stations (max. 17) and the expansion Regenerating the signals in amplitude and time Electrical isolation of the connected bus systems Data transmission rate Max. segment length 9.6 kbit/s m 19. kbit/s m kbit/s m kbit/s m kbit/s m 500 kbit/s 400 m kbit/s 00 m kbit/s 100 m kbit/s 100 m kbit/s 100 m 3 Siemens IK PI 015 3/65

215 PROFIBUS Electrical networks (RS485) Repeater RS 485 for PROFIBUS Technical specifications Ordering data Article No. 3 6ES797-0AA0-0XA0 Supply voltage 4 V DC Yes permissible range, lower limit (DC) 0.4 V permissible range, upper limit (DC) 8.8 V Input current Current consumption, max. 100 ma; 100 ma without loads at PG/ OP socket; 130 ma load at PG/OP socket (5 V/90 ma); 00 ma load at PG/OP socket (4 V/100 ma) Interfaces Bus cables terminal blocks PROFIBUS DP Transmission rate, max. 1 Mbit/s; 9.6 kbit/s to 1 Mbit/s Degree and class of protection IP0 Yes Ambient conditions Operating temperature Min. 0 C max. 60 C Storage/transport temperature Min. -40 C max. 70 C Relative humidity max. relative humidity 95 %; at 5 C Connection method Power supply Terminal block Dimensions Width 45 mm Height 18 mm Depth 67 mm Weights Weight, approx. 350 g RS 485 repeater for PROFIBUS Transfer rate up to max. 1 Mbit/s, 4 V DC, enclosure IP0 6ES797-0AA0-0XA0 More information Brochures Information material for downloading can be found in the Internet: 3/66 Siemens IK PI 015

216 PROFIBUS Electrical networks (RS485) Diagnostics repeater for PROFIBUS DP Overview RS 485 repeater with online line diagnostics for PROFIBUS DP DP standard PROFIBUS slave (DP-V1) Automatic determination of fault types and locations Data transmission rate 9.6 kbit/s to 1 Mbit/s Connection through FastConnect using the insulation displacement method Application The diagnostics repeater for PROFIBUS DP connects PROFIBUS DP segments with RS 485 technology. It also physically monitors the copper bus lines in online mode. If an error occurs, it sends a diagnostic message to the DP master with detailed information on the type and location of the error. The diagnostics repeater is a standard slave. It can be operated on any DP master that supports the standard RD_REC and WR_REC services. To record the topology, you will need either STEP 7 or COM PROFIBUS. Design Enclosure with degree of protection IP0 Assembly on S7-300 DIN rails or standard DIN rails LEDs to display 4 V DC, bus activity and line errors per segment Terminal block for external 4 V DC supply voltage 9-pin Sub-D socket for PG connection Connections for 3 bus segments with FastConnect insulation displacement connection The diagnostics repeater is integrated into the bus system as a PROFIBUS DP standard slave. It enables the following: - monitoring of PROFIBUS DP segments - max. 31 stations per segment (max. 6 stations per diagnostics repeater) - max. segment length 100 m (independent of the baud rate) - configuration of up to 9 diagnostics repeaters in a row Use only approved bus connectors on the diagnosticscapable segments (see Ordering Information/Accessories) Observe the configuration guidelines for 1 MBaud networks Function Mode of operation Repeater functionality The diagnostics repeater is integrated into the bus system as a RS 485 repeater, but it has its own PROFIBUS DP address: Expansion of extension in the bus system Regeneration of the signals in edge steepness, amplitude and time (re-timing) Isolates connected segments Configuration in STEP 7, COM PROFIBUS or also using a GSD file. As of FW Version V.0.0, the following additional functions will be supported: I&M functions according to PROFIBUS Guideline Order No in version V1.1, dated May 003 Time synchronization via S7 mechanisms DP cycle time measurement and statistics 3 Siemens IK PI 015 3/67

217 PROFIBUS Electrical networks (RS485) Diagnostics repeater for PROFIBUS DP 3 Function (continued) Technical specifications Diagnostic functionality 6ES797-0AB01-0XA0 Initiated by STEP 7, COM PROFIBUS or the user program Supply voltage (SIMATIC S7-400 / S7-300), the diagnostics repeater identifies 4 V DC Yes the topology of the connected segments and saves this information in the internal diagnostic memory. permissible range, lower limit (DC) 0.4 V If an error occurs, the repeater automatically transmits a permissible range, upper limit (DC) 8.8 V standard diagnostic message to the bus master with the Interfaces following information: Bus cables FastConnect insulation displacement, 10 clamping cycles possible Affected segment PROFIBUS DP Error location (e.g. between station X and Y) Transmission rate, max. 1 Mbit/s; 9.6 kbit/s to 1 Mbit/s Distance from stations X and Y as well as from the repeater in Degree and class of protection meters to the error location IP0 Yes Type of error Ambient conditions The following errors are diagnosed: Operating temperature Min. 0 C Break in signal lines A or B max. 60 C Short circuit of signal lines A or B on the shield Storage/transport temperature Absent terminating resistors Min. -40 C Unacceptable cascading depth (between any two nodes, max. 70 C no more than 9 repeaters be connected in series) Relative humidity Too many stations in a segment max. relative humidity 95 %; at 5 C Station too far from the diagnostics repeater Connection method Faulty messages Power supply Terminal block Dimensions Sporadic errors are also detected. Width 80 mm The error messages are displayed graphically in STEP 7 and Height 15 mm COM PROFIBUS. They are completely integrated in the SIMATIC system diagnostics (e.g. overview diagnostics, Depth 67.5 mm "Report system error" function). Weights The display in STEP7 also includes a help text with troubleshooting Weight, approx. 300 g measures. The help text is written in a way that does not require specific PROFIBUS expertise, so that the error can be quickly localized and removed. Network topology and statistics display You can view the topology graphically in Step 7 as of V5.. The stations and the line lengths are shown in the topology display. You can also view the bus system quality in the form of statistical information. Print function STEP 7 V53.3, SP 3 includes an improved print function. It allows you to preview on the screen and optimize the printout. For instance, you can hide certain details and print out an overview of the topology on DIN A4 or DIN A3 paper. Configuring The diagnostics repeater is configured as follows: STEP 7 V5.1 or higher, incl. Service Pack COM PROFIBUS V5.1, incl. Service Pack External tools: Use GSD file The topology can be determined using external masters with the help of the COM PROFIBUS. The topology cannot be identified using an external configuration tool. However, if the topology is determined once using the COM PROFIBUS, error location information will also be displayed in the external configuration tool. 3/68 Siemens IK PI 015

218 PROFIBUS Electrical networks (RS485) Diagnostics repeater for PROFIBUS DP Ordering data Article No. Article No. RS 485 Diagnostic Repeater 6ES797-0AB01-0XA0 Accessories (continued) For connection of 1 or segments to PROFIBUS DP; with online diagnostics functions for monitoring the bus cables Accessories RS 485 bus connector with 90 cable outlet With screw terminals Max. transfer rate 1 Mbit/s Without PG interface With PG interface PROFIBUS FastConnect bus connector RS 485 with 90 cable outlet 6ES797-0BA1-0XA0 6ES797-0BB1-0XA0 PROFIBUS FastConnect RS 485 bus connector with angular cable outlet (35 ) With insulation displacement terminals, max. transfer rate 1 Mbit/s Without PG interface With PG interface PROFIBUS FastConnect Stripping Tool Preadjusted stripping tool for fast stripping of PROFIBUS FastConnect bus cables PROFIBUS FC Standard Cable 6ES797-0BA60-0XA0 6ES797-0BB60-0XA0 6GK1905-6AA00 6XV1830-0EH10 3 With insulation displacement terminals Max. data transfer rate 1 Mbit/s Without PG interface 1 unit 6ES797-0BA5-0XA0 100 units 6ES797-0BA5-0XB0 With PG interface 1 unit 6ES797-0BB5-0XA0 100 units 6ES797-0BB5-0XB0 without PG interface, grounding via control cabinet cover 1 unit 6ES797-0BA70-0XA0 with PG interface, grounding via control cabinet cover 1 unit 6ES797-0BB70-0XA0 RS 485 bus connector with angled cable outlet (35 ) With screw terminals, max. transfer rate 1 Mbit/s Without PG interface 6ES797-0BA4-0XA0 With PG interface 6ES797-0BB4-0XA0 Standard type with special design for quick mounting, -core, shielded, sold by the meter, max. delivery unit m, minimum order quantity 0 m S7 Manual Collection Electronic manuals on DVD, multilingual: S7-00, TD 00, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) S7 Manual Collection update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates Connecting cable for PROFIBUS 1 Mbit/s, for PG connection to PROFIBUS DP, preassembled with x 9-pin sub D connector, 3.0 m 6ES7998-8XC01-8YE0 6ES7998-8XC01-8YE 6ES7901-4BD00-0XA0 More information Brochures Information material for downloading can be found in the Internet: Siemens IK PI 015 3/69

219 PROFIBUS Electrical networks (PROFIBUS PA) 3 Introduction Overview SIMATIC Fieldbus Calculator Direct interfacing of the devices in the field, especially in the hazardous area, together with the information content of the communication, are of significant importance in the process industry. PROFIBUS PA, which permits both digital data transmission and the power supply on a two-wire line with the intrinsically-safe MBP transmission technology (Manchester Coded; Bus Powered) is tailored to these requirements. It is optimally suitable for direct integration of solenoid valves, sensors, and pneumatic actuators positioned in operating environments up to Ex zone 1/1 or 0/0 into the process control system. The typical response time of a transmitter of approx. 10 ms indicates that short cycle times can be achieved with the PROFIBUS PA even in the case of a segment configuration with up to 31 devices. Practically all typical applications of the process industry can be implemented, both in small and large plants. Bidirectional communication and high information content allow enhanced diagnostics for fast and exact fault detection and elimination. The standardized communications services guarantee interoperability and replaceability between multi-vendor field devices and remote configuration of the field devices during operation. Safety communication with the PROFIsafe profile The PROFIsafe profile allows seamless integration of safety communication into the PROFIBUS PA. You need not configure a separate safety bus for your safety-related applications. The PROFIBUS PA with the PROFIsafe profile is incorporated in "Safety Integrated for Process Automation". This comprehensive range of products and services from Siemens for failsafe, faulttolerant applications in the process industry offers you attractive and cost-effective alternatives to separate safety systems. Redundant architectures You can define the degree of redundancy separately for the controller, fieldbus and I/O levels of your plant depending on the automation task and the derived safety requirements, and match them to the field instrumentation (Flexible Modular Redundancy, FMR). You can find an overview of the redundant architectures of PROFIBUS PA under "Design". Network transition PROFIBUS PA to PROFIBUS DP The PA link is preferred as the gateway from PROFIBUS PA to PROFIBUS DP. When using the PA link, the transmission rate on the PROFIBUS DP is independent of the lower-level PROFIBUS PA segments. The configuration of the PA link depends on the fieldbus architecture. The types of coupler described in the section "PA routers" can be used for the configuration. With a small volume of data (small quantity structure) and low time requirements, the DP/PA coupler can also be operated in standalone mode as a gateway. Benefits Advantages provided by distributed field automation with application of the PROFIBUS PA profile included low hardware overhead, cost-effective engineering, increased operational safety and problem-free maintenance. These advantages are underlined by the following features: Modularity and uniformity from the sensor up to the control level permit new plant concepts Implementation of intrinsically-safe applications through use of the fieldbus in hazardous areas Redundant PROFIBUS PA architectures (ring and line topologies with coupler redundancy) support Flexible Modular Redundancy (FMR) from the automation system (controller) down to a PA field device Safety-related and fault-tolerant applications with low device and cabling requirements Reduced configuration costs through simple, central engineering of the field devices (PROFIBUS PA and HART with SIMATIC PDM, also cross-vendor) Simple installation using two wire cable for common power supply and data transmission Reduced commissioning costs through simplified loop check Low servicing costs thanks to simple wiring and comprehensive diagnostics facilities 3/70 Siemens IK PI 015

220 Design PROFIBUS DP SIMATIC PCS 7 automation system PA link PROFIBUS PA PA link PROFIBUS PA AFS PA link PROFIBUS PA PA link PROFIBUS PA AFD AFD Basic PROFIBUS PA design versions when using the PA link as the PA router AFD AFD AFD AFD AFDiS AFDiS AFDiS Basic PROFIBUS PA design versions are shown at this point. The PA link is used as the PA router in these configuration examples. However, the PA router can only be implemented per DP/PA coupler. The PROFIBUS DP connection is then directly on the coupler instead of per interface module. The number of PROFIBUS PA devices is limited according to the specifications in section "Technical data". G_PCS7_XX_00146 PROFIBUS Electrical networks (PROFIBUS PA) Introduction Line architecture with single coupler Max. 5 PROFIBUS PA lines (line segments) can be operated via single couplers (max. 3 for mixed configurations with ring or coupler redundancy) on a PA link as PA router, equipped with up to 5 DP/PA couplers. In the line architecture with individual couplers, each line segment is connected to one DP/PA coupler of the PA router. The PA router can be connected to a single or redundant PROFIBUS DP. The FDC the first choice as the DP/PA coupler. When using this coupler, the PA devices can be integrated into the line segment via active field distributors AFD4 and AFD8 (approval for Ex zone /) and AFDiS (approval for Ex zone 1/1). The PA devices are connected to these field distributors via shortcircuit-proof spur lines. Up to 8 field distributors of type AFD4/AFD8, 5 field distributors of type AFDiS, or 5 field distributors of both AFDiS and AFD4/ AFD8 types combined can be optionally operated in a line segment. The last field distributor at the end of the line leading away from the DP/PA coupler automatically activates its bus terminating resistor. Intrinsically-safe PA devices in hazardous areas in accordance with Ex zone 1/1 or 0/0 are primarily integrated into a bus segment by means of active field distributors AFDiS. For PA devices in Ex zone 1/1, the connection via a line segment on the PA router with DP/PA coupler Ex [i] is a possible alternative. The devices are integrated separately into the line segment via SplitConnect Taps (via spur line or directly via SplitConnect M1 outlet). A SplitConnect terminator is required for the bus termination of the segment. By grouping individual devices in different line segments, Flexible Modular Redundancy is possible at device level. Line architecture with redundant coupler The PA link operable as a PA router on a single or redundant PROFIBUS DP can only be equipped with one redundant DP/PA coupler pair (up to 3 single couplers can also be optionally configured). The redundant DP/PA coupler pair can be used either for a line architecture with Active Field Splitter (AFS) or for a ring architecture. With a line architecture, the AFS is connected to the redundant DP/PA coupler pair ( x FDC 157-0) in the PA router. It connects the line segment connected to it to the active of the two redundant DP/PA couplers. A DP/PA coupler can be replaced without interrupting the ongoing operation. The PA devices are integrated in the line segment as for a line architecture with single couplers via active field distributors AFD4, AFD8 or AFDiS. The limits with respect to the number of field distributors are also identical (up to 8 AFD4/AFD8, up to 5 AFDiS or up to 5 AFDiS and AFD4/AFD8 in any combination). 3 Siemens IK PI 015 3/71

221 PROFIBUS Electrical networks (PROFIBUS PA) Introduction 3 Design (continued) Technical specifications Ring architecture with coupler and media redundancy PROFIBUS PA With the redundant DP/PA coupler pair ( x FDC 157-0) of a Data transmission MBP PA router, a ring segment with automatic bus termination can also be implemented instead of a line segment with AFS. Transmission rate 31.5 Kbps Apart from the ring segment, only line segments with individual Cable -wire shielded couplers can be configured on this PA router. The PA router can Type of protection EEx(ia/ib) be connected to a single or a redundant PROFIBUS DP. Topology Line, tree, ring Integration of the PA field devices into the ring segment is Active field distributors per segment/ carried out via active field distributors AFD4, AFD8 or AFDiS, coupler the number of which is limited as with the line architectures AFD4/AFD8 8 (up to 8 AFD4/AFD8, up to 5 AFDiS or up to 5 AFDiS and AFDiS or combinations of 5 AFD4/AFD8 in any combination). These field distributors have AFDiS and AFD4/AFD8 electrically decoupled, short-circuit-proof spur line connections PA devices per segment/coupler 31 for connecting the PA devices. PA devices per PA link 64 At the device level, flexible modular redundancy is possible by grouping individual devices on different field distributors. Max. current for all PA field devices 1A of a segment (for PA gateways with Special advantages of the ring architecture: FDC coupler) High availability Cable length per segment, m: standard dependent on transmission rate m: EEx(ib) Transparent redundancy management of the intelligent DP/PA m: EEx(ia) couplers FDC for the host system Bus segments with AFD4/AFD8 Active bus terminators for automatic bus termination in the Max. spur line length related to the DP/PA couplers FDC and the active field distributors total number of spur lines AFD4, AFD8 and AFDiS enable: Number of spur lines - Automatic, smooth isolation of faulty subsegments in the (1 device per spur line) event of a short-circuit or open-circuit 1 to 1 spur lines 10 m - Modification of the ring configuration or instrumentation 13 to 14 spur lines 90 m during operation, including the addition or removal of ring 15 to 18 spur lines 60 m segments 19 to 4 spur lines 30 m Safety-related and fault-tolerant applications with low device 5 to 31 spur lines 1m and cabling requirements Bus segments with AFDiS Max. spur line length independent of Cable lengths of bus segments and spur lines total number of spur lines The PROFIBUS PA is based on electrical transmission components. A shielded two-wire cable is used for digital data trans- (1 device per spur line) Number of spur lines mission and for the power supply of the field devices. 1 to 31 spur lines - Not intrinsically-safe 10 m With line, tree and ring topologies, bus segments up to approx. - Intrinsically-safe acc. to FISCO 60 m 1.9 km can be configured. If AFD4/AFD8 active field distributors are used, the length of the spur lines for connecting devices and the quality of the cable used must also be considered when calculating the total length of the bus segment. Spur lines on the AFDiS are not relevant to the total length of the bus segment. For bus segments with active field distributors, the spur lines can have the following maximum lengths: Up to 10 m in accordance with IEC Up to 60 m in accordance with IEC (FISCO) With AFD4/AFD8 active field distributors, these maximum values may be reduced depending on the number of spur lines of the bus segment (for details, see section "Technical specification"). With the active field distributor AFDiS, this reduction is canceled by the integrated repeater function. The SIMATIC Fieldbus Calculator provides help in calculating and designing fieldbus segments: Intrinsically-safe PA devices in hazardous areas are preferably integrated into a bus segment by means of active field distributors AFDiS. For PA devices in Ex zone 1/1, the connection via a line segment on the PA router with DP/PA coupler Ex [i] is a possible alternative. In such a configuration the max. possible length per spur line is reduced to 30 m and per bus segment to 1 km. Bus segments are terminated either automatically (with architectures with active field distributors AFD4, AFD8, AFDiS) or with the passive terminating element for PROFIBUS PA (SpliTConnect terminator). 3/7 Siemens IK PI 015

222 PROFIBUS Electrical networks (PROFIBUS PA) SpliTConnect Overview Benefits Easy connection of terminals due to use of the FastConnect system Wide variety of applications thanks to modular SpliTConnect system Reduction in number of types and parts thanks to uniform connection system for PROFIBUS PA 3 Used for constructing fieldbus segments as per IEC (e.g. PROFIBUS PA) with field device interface points Easy assembly of the bus cable thanks to the FastConnect system (FastConnect stripping tool, FC process cable compliant with IEC ) The terminal devices can be connected using the FC Process Cable in accordance with IEC or the SpliTConnect M1 Outlet/M1 Jack Combination of terminating resistors can be integrated (SpliTConnect terminator) Application The SpliTConnect Tap enables the design of fieldbus segments according to IEC (e.g. PROFIBUS PA) with terminal device connection points. The SpliTConnect Coupler can be used to construct a PROFIBUS PA hub by connecting SpliTConnect Taps in series. By replacing the contacting screw with the SpliTConnect terminator, the SpliTConnect tap can be used as a bus terminating element G_IK10_XX_50011 Siemens IK PI 015 3/73

223 PROFIBUS Electrical networks (PROFIBUS PA) SpliTConnect Design Function The SpliTConnect tap enables configuration of fieldbus segments according to IEC (e.g. PROFIBUS PA) and connection of terminals Easy pre-assembly of the SpliTConnect taps through the FastConnect connection system (FastConnect stripping tool, FC Process Cable) Connection of the terminals directly through FC Process Cable or SpliTConnect M1 outlet 3 SpliTConnect Coupler SpliTConnect M1 Outlet SpliTConnect Terminator SpliTConnect M1 Jack Rugged plastic casing made of PBT (polybutylene terephthalate) in IP67 design UV-resistant, making it possible to use outdoors Complete shielding by means of integrated metal enclosure Easier cable connection through the use of FC process cable Contacting and connection of the FC process cable by means of ID contacts using contacting screw Additional grounding of the SpliTConnect tap possible by using a contacting screw DIN rail mounting or wall mounting possible DP/PA link SpliTConnect terminator SpliTConnect coupler SpliTConnect taps FC Process cable SpliTConnect M1 Jack SpliTConnect M1 Outlet for direct connection of PA field devices to the SpliTConnect tap Connector on PA field device 3/74 Siemens IK PI 015

224 PROFIBUS Electrical networks (PROFIBUS PA) SpliTConnect Technical specifications Article No. 6GK1905-0AA00 6GK1905-0AB10 6GK1905-0AC00 Product-type designation SpliT Connect Tap SpliT Connect M1 Outlet SpliT Connect Coupler Interfaces Number of electrical connections for PROFIBUS cables for network components and terminal equipment Design of the electrical connection for PROFIBUS cables integrated insulation displacement - - contacts FastConnect Mechanical data Cable gland version Material of the enclosure PBT (polybutyleneterephthalate) - - Design, dimensions and weight Width 84 mm - - Height 54 mm - - Depth 49 mm - - Net weight 170 g - - Mounting type Yes mm DIN rail mounting Mounting type wall mounting Yes - - Permitted ambient conditions Ambient temperature during operating C C C during storage C C C during transport C C C Protection class IP IP67 IP67 IP67 Product properties, functions, components general Verification of suitability UL-registration Yes Article No. 6GK1905-0AD00 6GK1905-0AE00 6GK1905-0AF00 Product-type designation SpliT Connect Terminator (Ex) SpliT Connect Terminator (non-ex) SpliT Connect M1 Jack Interfaces Number of electrical connections for PROFIBUS cables for network components and terminal equipment Design of the electrical connection for PROFIBUS cables - - integrated insulation displacement contacts FastConnect Mechanical data Material of the enclosure Design, dimensions and weight Width Height Depth Net weight Mounting type mm DIN rail mounting Mounting type wall mounting Permitted ambient conditions Ambient temperature during operating C C C during storage C C C during transport C C C Protection class IP IP67 IP67 IP67 Product properties, functions, components general Verification of suitability UL-registration Siemens IK PI 015 3/75

225 PROFIBUS Electrical networks (PROFIBUS PA) SpliTConnect Ordering data Article No. Article No. SpliTConnect Tap For assembling PROFIBUS PA segments and connecting PA field devices, insulation displacement method, IP67 6GK1905-0AA00 SpliTConnect terminator (Ex version) For terminating PROFIBUS PA segments, can be used in hazardous areas 6GK1905-0AD00 Type of delivery: 1 package = 10 items Type of delivery: 1 package = 5 items 3 SpliTConnect M1 outlet Element for direct connection of PROFIBUS PA field devices to the SpliTConnect tap through M1 connection 6GK1905-0AB10 SpliTConnect terminator (non-ex version) For terminating PROFIBUS PA segments, cannot be used in hazardous area 6GK1905-0AE00 Type of delivery: 1 package = 5 items Type of delivery: 1 package = 5 items SpliTConnect coupler 6GK1905-0AC00 SpliTConnect M1 jack 6GK1905-0AF00 Coupling element for connecting SpliTConnect taps in series to configure star points Type of delivery: 1 package = 10 items Connector element for direct connection of PROFIBUS PA field devices to the PROFIBUS PA segment through M1 connection Type of delivery: 1 package = 5 items 3/76 Siemens IK PI 015

226 PROFIBUS Electrical networks (PROFIBUS PA) Bus cables Overview Benefits Bus cable for fieldbus systems according to IEC , e.g. PROFIBUS PA High interference immunity thanks to double shielding Different variants for different applications (hazardous areas, non-hazardous areas) Easy length measurement thanks to printed meter markings Length can easily be determined due to meter length markings printed on the cable Complete range of cables for hazardous and non-hazardous areas Reduction of types and parts thanks to a uniform connection system for PROFIBUS PA Application For the construction of fieldbus networks according to IEC (for example PROFIBUS PA), different color-coded cable types are available for the different types of applications (hazardous, non-hazardous areas). UL approvals Different cable variants are offered with appropriate UL approvals for laying in cable bundles and cable racks according to the specifications of NEC (National Electrical Code) Article 800/75. Design Shielded, twisted-pair cable with circular cross-section System-wide grounding concept can be implemented using the external shield of the bus cable and the grounding terminals of the SpliTConnect system. Printed meter marks. Cable types FC Process Cable: Special bus cable compliant with IEC for use in hazardous (Ex) and non-hazardous (non-ex) areas. Bus segments with RS485 and IEC transmission procedures are linked by means of the segment coupler/link. 3 Siemens IK PI 015 3/77

227 PROFIBUS Electrical networks (PROFIBUS PA) Bus cables Technical specifications 3 Article No. 6XV1830-5FH10 6XV1830-5EH10 Product-type designation PROFIBUS FC Process Cable GP PROFIBUS FC Process Cable GP Product description Bus cable (-core), sold by the meter, in bulk Bus cable (-core), sold by the meter, in bulk Acceptability for application For use in fieldbus systems according to IEC (e.g. PROFIBUS PA), suitable for non-ex applications For use in fieldbus systems according to IEC (e.g. PROFIBUS PA), suitable for Ex applications Cable designation 0YSY (ST) CY 1xx1.0/ SW OE FR 0YSY (ST) CY 1xx1.0/ BL OE FR Cable length - - Electrical data Damping ratio per length 3dB/km 3dB/km at 38.4 khz maximum Impedance Nominal value at 31.5 khz Relative symmetrical tolerance of 0 % 0 % surge impedance at 31.5 khz Loop resistance per length 44 /km 44 /km maximum Shield resistance per length 6.5 /km 6.5 /km maximum Capacity per length at 1 khz 9 pf/m 9 pf/m Inductance per length 0.65 µh/m 0.65 µh/m Operating voltage RMS value 100 V 100 V Mechanical data Number of electrical wires Design of shield Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires Design of the electrical connection Yes Yes FastConnect Outer diameter of the inner conductor 1.05 mm 1.05 mm of the wire insulation.55 mm.55 mm of the inner sheath of the cable 5.4 mm 5.4 mm of the cable sheath 8mm 8mm Symmetrical tolerance of outer 0.4 mm 0.4 mm diameter of cable sheath Outer diameter of the cable sheath - - Note Material of the wire insulation PE PE of the inner sheath of the cable PVC PVC of the cable sheath PVC PVC -Note - - Color of the insulation of data wires red / green red / green of the cable sheath Black Blue Bending radius with single bend minimum 40 mm 40 mm permissible with multiple bends minimum permissible 80 mm 80 mm with continuous bending - - Number of bending cycles - - Note - - Number of torsion cycles with torsion - - by ± 180 on 1 m cable length Traction stress maximum 150 N 150 N Weight per length 103 kg/km 103 kg/km 3/78 Siemens IK PI 015

228 PROFIBUS Electrical networks (PROFIBUS PA) Bus cables Technical specifications (continued) Article No. 6XV1830-5FH10 6XV1830-5EH10 Product-type designation PROFIBUS FC Process Cable GP PROFIBUS FC Process Cable GP Permitted ambient conditions Ambient temperature during operating C C during storage C C during transport C C during installation C C Ambient condition for (standard) Transfer rate of cable: 31.5 Kbit/s Transfer rate of cable: 31.5 Kbit/s operation mode Protection class IP - - Burning behaviour flame resistant according to IEC (Category C) flame resistant according to IEC (Category C) Chemical resistance to mineral oil Conditional resistance Conditional resistance to grease Conditional resistance Conditional resistance to water Conditional resistance Conditional resistance Radiological resistance to Resistant Resistant UV radiation Product properties, functions, components general Product feature halogen-free No No silicon-free Yes Yes Standards, specifications, approvals UL/ETL listing with 300 V rating Yes: c(ul)us, CMG / CL3 / Sun Res Yes: c(ul)us, CMG / CL3 / Sun Res UL/ETL style with 600 V rating Verification of suitability CE mark Yes Yes UL-registration - - RoHS conformity Yes Yes 3 Ordering data Article No. More information PROFIBUS FC Process Cable -core, shielded Blue for Ex applications Black for non-ex applications Sold by the meter: Max. quantity m; minimum order 0 m PROFIBUS FastConnect Stripping Tool Stripping tool for fast stripping of the PROFIBUS FastConnect bus cable PROFIBUS FastConnect Blade Cassettes Spare blade cassettes for PROFIBUS FastConnect stripping tool, 5 units SIMATIC NET Manual Collection Electronic manuals for communication systems, communication protocols, and communication products; on DVD; German/English 6XV1830-5EH10 6XV1830-5FH10 6GK1905-6AA00 6GK1905-6AB00 6GK1975-1AA00-3AA0 Installation instruction FastConnect The FastConnect stripping tool can be used to strip the outer sheath and shield of the FC Process Cable to the required lengths for PROFIBUS PA. Thus the use of the FastConnect stripping tool and SpliTConnect tap permits the easy connection of field devices to, for example, the PROFIBUS PA bus system. Cable routing During storage, transport and cable laying, keep both ends sealed with a shrink-on cap. Comply with the permissible bending radii and tensile load! Note: You can order components supplementary to the SIMATIC NET cabling range from your local contact. Technical advice on this subject is available from: J. Hertlein I IA SC CI PRM 4 Phone: +49 (911) [email protected] Siemens IK PI 015 3/79

SIMATIC IPC477D 1/5. Copyright Siemens AG 2014

SIMATIC IPC477D 1/5. Copyright Siemens AG 2014 Product data sheet (Panel PC): The powerful embedded Panel PC maintenance-free with versatile configuration Embedded PC platform with extremely high industrial compatibility for demanding tasks in the

More information

Panel PC SIMATIC HMI IPC577C

Panel PC SIMATIC HMI IPC577C Product Data Sheet Rugged, expandable industry PC for demanding tasks in the area of PC-based automation with various control units (front panels): Rugged and compact design for industrial use Full PC

More information

Turn on and immediately start with the engineering! siemens.com/simatic-pg

Turn on and immediately start with the engineering! siemens.com/simatic-pg SIMATIC Field PG M5 Turn on and immediately start with the engineering! siemens.com/simatic-pg Mobile engineering in industrial environments For mobile applications in industrial plants, the SIMATIC Field

More information

SIMATIC HMI IPC 477C 1/5. Copyright Siemens AG 2013

SIMATIC HMI IPC 477C 1/5. Copyright Siemens AG 2013 Product Data Sheet SIMATIC HMI IPC477C: The powerful embedded Panel PC maintenance-free with versatile configuration Embedded PC platform with extremely high industrial compatibility for demanding tasks

More information

140 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370

140 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 140 PHOENIX CONTACT Industrial PCs for the control cabinet The industrial PC solutions from Phoenix Contact offer top performance for your automation solutions in an industrial environment. Innovative

More information

DCS Data and communication server

DCS Data and communication server 8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With

More information

Scout 1U Rackmount Computer

Scout 1U Rackmount Computer Model Numbers ACC-CPU-RM- WIN7x64 ACC-CPU-RM-2008 Revision 5 Scout 1U Rackmount Computer Introduction The Scout 1U Rackmount Computer includes a solid state hard drive loaded with the Microsoft Windows

More information

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor Servers, Clients Displaying max. 60 cameras at the same time Recording max. 80 cameras Desktop or rackmount form factor IVR-40/40-DSKT Intellio standard server PC 60 60 Recording 60 cameras Video gateway

More information

System Configuration and Order-information Guide ECONEL 100 S2. March 2009

System Configuration and Order-information Guide ECONEL 100 S2. March 2009 System Configuration and Orderinformation Guide ECONEL 100 S2 March 2009 Front View DVDROM Drive 5 inch Bay Floppy Disk Drive Back View Mouse Keyboard Serial Port Display 10/100/1000BASET Connector Inside

More information

Data Sheet. CELSIUS W370 E80+ Your gateway to workstation power

Data Sheet. CELSIUS W370 E80+ Your gateway to workstation power Data Sheet CELSIUS W370 E80+ Your gateway to workstation power Issue: August 2009 CELSIUS W370 E80+ The CELSIUS W series is the versatile all-round workstation for price-conscious users. Offering entry

More information

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay -1- GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay Introduction The GV Hot Swap Backup Center System, designed for large scale video surveillance deployments, provides a secure remote backup

More information

FUJITSU Enterprise Product & Solution Facts

FUJITSU Enterprise Product & Solution Facts FUJITSU Enterprise Product & Solution Facts shaping tomorrow with you Business-Centric Data Center The way ICT delivers value is fundamentally changing. Mobile, Big Data, cloud and social media are driving

More information

Data Sheet. CELSIUS W370 E80+ Your gateway to workstation power

Data Sheet. CELSIUS W370 E80+ Your gateway to workstation power Data Sheet CELSIUS W370 E80+ Your gateway to workstation power Issue: November 2009 CELSIUS W370 E80+ The CELSIUS W series is the versatile all-round workstation for price-conscious users. Offering entry

More information

Cisco MCS 7825-H3 Unified Communications Manager Appliance

Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables

More information

QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview

QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview Overview Front 1. Power Button 2. Power Indicator Light 3. Hard Disk Drive Indicator Light 4. Optical Disk Drive Ejection Button 5. Media Card Reader Indicator Light 6. 7-in-1 Media Card Reader (optional)

More information

SIMATIC Rack PCs. Introduction 1/3. Overview

SIMATIC Rack PCs. Introduction 1/3. Overview Siemens G 202 Overview With the SIMTIC PCS 7 Industrial Workstation of the type IPC547D, we offer you an excellent platform for the configuration of single stations, servers or clients for SIMTIC PCS 7

More information

Cisco MCS 7816-I3 Unified Communications Manager Appliance

Cisco MCS 7816-I3 Unified Communications Manager Appliance Cisco MCS 7816-I3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables

More information

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I Highly Scalable Server for Many Possible Uses MAXDATA PLATINUM Server 3200 I MAXDATA PLATINUM Server 3200 I: Highly Scalable Server for Many Possible Uses Standard Features Now more than ever, profitable

More information

DCS data and communication server

DCS data and communication server 8 578 VISONIK DCS data and communication server PLD0.ECO/DGL PLD0.ECO/PCM Data and communication servers (DCS) are used as management station in building automation and control (BAC). With DDC technology,

More information

Box PC Fanless. Box PC Performance

Box PC Fanless. Box PC Performance Box PC Fanless Box PC systems based on Atom, Celeron ULV and Core 2 Duo ULV processors, for wall or DIN rail mount, designed to meet the specific needs of the industrial automation market. Box PC Performance

More information

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server The ideal first server FUJITSU Server PRIMERGY will give you the servers you need to

More information

Application Server V240 Platform

Application Server V240 Platform Application Server V240 Platform The V240 Application Server (V240) features four hot-swappable disks with redundant power supplies for reliable system performance. The server also has three PCI slots

More information

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server The ideal first server FUJITSU Server PRIMERGY systems provide the most powerful and

More information

Chapter 5 Cubix XP4 Blade Server

Chapter 5 Cubix XP4 Blade Server Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control

More information

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X System Configuration and Order-information Guide RX00 S4 February 008 Front View CD-ROM Drive (Optional) Hard Disk Bay Back View PCI Slot 0/00/000BASE-T connector Serial Port Display Mouse Keyboard Inside

More information

SIMATIC IPC647D SIMATIC. Industrial PC SIMATIC IPC647D. Preface. Overview. Safety Instructions 2. Installing and connecting the device 3

SIMATIC IPC647D SIMATIC. Industrial PC SIMATIC IPC647D. Preface. Overview. Safety Instructions 2. Installing and connecting the device 3 Preface Overview 1 SIMATIC Industrial PC Operating Instructions Safety Instructions 2 Installing and connecting the device 3 Commissioning the device 4 Extended device functions 5 Expanding and assigning

More information

ACER INC. VERITON M200 QUICK SPEC

ACER INC. VERITON M200 QUICK SPEC ACER INC. VERITON M200 QUICK SPEC Designed to meet the demanding needs of your business Veriton M200-H61 offers uncompromising value for money while focused on providing the maximum expandability that

More information

Rugged and open to your applications

Rugged and open to your applications Rugged and open to your applications Magelis industrial PCs Opti PC, Smart, Smart+, Compact ipc, Smart BOX, Compact BOX, Flex PC BOX, and idisplay Windows XP TM Compact Flash Flash disk Hard disk Magelis

More information

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server The ideal first server FUJITSU Server PRIMERGY systems provide the most powerful and

More information

Optimized dual-use server and high-end workstation performance

Optimized dual-use server and high-end workstation performance Optimized dual-use server and high-end workstation performance The ATX-sized(EEB mounting hole locations) Z9PA-U8 supports the latest Intel Xeon processor E5-2600 and E5-1600 product family, featuring

More information

Data Sheet Fujitsu ESPRIMO P2440 Desktop PC

Data Sheet Fujitsu ESPRIMO P2440 Desktop PC Data Sheet Fujitsu ESPRIMO P2440 Desktop PC Your immediately available Office PC ESPRIMO P2440 Equipped with proven AMD technology the ESPRIMO P2440 is the best choice for cost-conscious buyers in small

More information

Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server

Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server Enter the world of PRIMERGY TX servers FUJITSU Server PRIMERGY systems provide the most

More information

Fujitsu ESPRIMO P2560 Desktop PC

Fujitsu ESPRIMO P2560 Desktop PC Datasheet Fujitsu ESPRIMO P2560 Desktop PC Your immediately available Office PC ESPRIMO P2560 The ESPRIMO P2560 is designed for price-conscious customers and is equipped with state-of-the-art standard

More information

Product Specifications. Shuttle Barebone D10. Shuttle Mini-PC with 7" Touchscreen. Feature Highlight. www.shuttle.com

Product Specifications. Shuttle Barebone D10. Shuttle Mini-PC with 7 Touchscreen. Feature Highlight. www.shuttle.com Shuttle Mini-PC with 7" The embedded touchscreen display delivers the simplest operation by giving you the multiple functions beyond your image. In addition, you can spread your work or entertainment over

More information

Siemens AG 2013 SIMATIC IPC. The More Industrial PC SIMATIC IPC. Edition April 2013. Brochure. Answers for industry.

Siemens AG 2013 SIMATIC IPC. The More Industrial PC SIMATIC IPC. Edition April 2013. Brochure. Answers for industry. SIMATIC IPC The More Industrial PC SIMATIC IPC Brochure Edition April 2013 Answers for industry. SIMATIC IPC The More Industrial PC For more than two decades now, Siemens has offered hardware and software

More information

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000 Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000 Datasheet for Red Hat certification PRIMERGY CX1000 is a new product category within the PRIMERGY x86 server family. Its focus

More information

Cisco 7816-I5 Media Convergence Server

Cisco 7816-I5 Media Convergence Server Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from

More information

Easily Upgrade to the Quad Core CPU without Additional Mechanism Rebuilding Costs

Easily Upgrade to the Quad Core CPU without Additional Mechanism Rebuilding Costs Easily Upgrade to the Quad Core CPU without Additional Mechanism Rebuilding Costs Touch Enabled Second Display PCI/PCIe Expansion Capability Specifications Datasheet Large Image Packing List Order Information

More information

LaCie 12big Rack Network

LaCie 12big Rack Network LaCie The Ultimate Corporate File-Sharing Solution. Network-Attached and Block Storage up to 96TB Customizable. Robust. Enterprise Class. Network-Attached Storage Just Got 12 Times Better. A Complete Network

More information

COMPUTING INDUSTRIAL EMBEDDED RUGEDIZED 19 INDUSTRIE PC

COMPUTING INDUSTRIAL EMBEDDED RUGEDIZED 19 INDUSTRIE PC ADLI MXE-1301 ADLI MXE-1302 Feature Intel Atom D2550/N2600 processor + NM10 chipset Supports 3.5" HDD with internal SATA II interface (MXE-1311) 2 software-programmable RS-232/422/485 + 2 RS-232 ports

More information

Executive Series. Intel Desktop Board DB75EN Executive Series MicroATX Form Factor

Executive Series. Intel Desktop Board DB75EN Executive Series MicroATX Form Factor Intel Desktop Board DB75EN MicroATX Form Factor product brief Built for Business: Intel Desktop Board DB75EN maximizes employee productivity, PC performance, and data security with Intel Small Business

More information

Data Sheet ESPRIMO P1500. The wide-ranging home office and multimedia PC ESPRIMO P1500

Data Sheet ESPRIMO P1500. The wide-ranging home office and multimedia PC ESPRIMO P1500 Pages: Data Sheet The wide-ranging home office and multimedia PC Issue: November 2009 The wide-ranging is the ideal home office and multimedia PC for families. Equipped with powerful Intel processor and

More information

Datasheet. Workstation

Datasheet. Workstation Datasheet Fujitsu CELSIUS R570 Workstation Your compact powerhouse workstation The CELSIUS R series is the dual-processor platform for the mid-range and high-end segment with a great selection of graphics

More information

Data Sheet Fujitsu PRIMERGY TX120 S3p Server

Data Sheet Fujitsu PRIMERGY TX120 S3p Server Data Sheet Fujitsu PRIMERGY TX120 S3p Server For small environments with high demands PRIMERGY TX tower servers are ideal for use in SMEs or branch offices. They increase operational efficiency by providing

More information

Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server

Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server Enter the world of PRIMERGY TX servers Fujitsu Server PRIMERGY TX Tower Servers are ideal for use in SMEs or branch offices. They increase operational

More information

Ampro by ADLINK Computer Systems

Ampro by ADLINK Computer Systems Ampro by ADLINK Computer Systems General Overview Ampro by ADLINK provides system products that deliver quality, reliability, durability, compatibility, high performance and long product lifecycle. The

More information

Minimum Hardware Specifications Upgrades

Minimum Hardware Specifications Upgrades Minimum Hardware Specifications Upgrades http://www.varian.com/hardwarespecs Eclipse TM treatment planning system Hardware V 11.0 1 TPS Version 11.0 Minimum Hardware Specifications [DELL OS supported upgrade

More information

Artikel-Detailinformationen

Artikel-Detailinformationen Artikel-Detailinformationen Hersteller Hewlett-Packard Hewlett-Packard Bezeichnung 1 EliteDesk 800 G1 SFF EliteDesk 800 G1 SFF Bezeichnung 2 i5-4570, 1x4GB, 500GB+20GB SSD i7-4770, 2x4GB, 256GB SSD, DVDRW

More information

Artikel-Detailinformationen

Artikel-Detailinformationen Artikel-Detailinformationen Hersteller Art-Nr Hewlett-Packard 0110675M Bezeichnung 1 Compaq 6200 Pro SFF i3-2100 Bezeichnung 2 1x2GB, 250GB, Win 7 Pro 64, DFEI Bezeichnung 3 DVD+/-RW, Intel HD Graphics

More information

Secu6 Technology Co., Ltd. Industrial Mini-ITX Intel QM77 Ivy Bridge Mobile Motherboard Support 3 rd Generation Core i7 / i5 / i3 Mobile Processor

Secu6 Technology Co., Ltd. Industrial Mini-ITX Intel QM77 Ivy Bridge Mobile Motherboard Support 3 rd Generation Core i7 / i5 / i3 Mobile Processor ITX-QM77 Industrial Mini-ITX Intel QM77 Ivy Bridge Mobile Motherboard Support 3 rd Generation Core i7 / i5 / i3 Mobile Processor Datasheet 2012.09.19» Intel Ivy Bridge (IVB) 3rd Generation Core i3 / i5

More information

QuickSpecs. HP 280 G1 Microtower Business PC. Overview

QuickSpecs. HP 280 G1 Microtower Business PC. Overview Overview Front 1. Half-height Bay - supporting an optical disk drive (optional) 2. Power Button 3. PC Status LED 4. (2) USB 2.0 Ports 5. 3.5mm Microphone Jack 6. 3.5mm Headphone Output 7. 6-in-1 Media

More information

Data Sheet Fujitsu CELSIUS W280 Workstation

Data Sheet Fujitsu CELSIUS W280 Workstation Data Sheet Fujitsu CELSIUS W280 Workstation Workstation power, PC format The CELSIUS W280 is the manageable workstation for when a traditional PC just isn t enough. Powered by the latest Intel processors

More information

High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis

High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis High Performance 2U Storage Server Based on the Intel Socket R E5-2600 processor platform, the ASUS RS720-E7/RS12 server offers customers an extensive feature set: mass storage. high memory capacity, outstanding

More information

Data Sheet Fujitsu CELSIUS M470 Workstation

Data Sheet Fujitsu CELSIUS M470 Workstation Data Sheet Fujitsu CELSIUS M470 Workstation Your new thoroughbred workstation CELSIUS M470 The CELSIUS M Series is the single-processor platform with a particularly well-balanced ratio between price and

More information

Light Industrial Panel PC

Light Industrial Panel PC Light Industrial Panel PC 7 ~15.6 Light Industrial Interactive Panel PC Features 7 ~15.6 light industrial interactive panel PC 9 V ~ 30 V wide range DC input with lockable DC jack Selectable AT/ATX power

More information

Data Sheet. Workstation. The new uncompromising high-end workstation. Windows. Life without Walls. Fujitsu recommends Windows 7.

Data Sheet. Workstation. The new uncompromising high-end workstation. Windows. Life without Walls. Fujitsu recommends Windows 7. Data Sheet Fujitsu CELSIUS R670 Workstation Datasheet for Red Hat certification The new uncompromising high-end workstation The CELSIUS R series is the dual-processor platform for the mid-range and high-end

More information

LB-IPC. High Performance, Ultra Low Noise Low Power Consumption. Features. Applications

LB-IPC. High Performance, Ultra Low Noise Low Power Consumption. Features. Applications LB-IPC High Performance, Ultra Low Noise Low Power Consumption Features Support Intel Pentium M and Celeron M 400/533 FSB Processor up to 2.13GHz Intel 915GM / ICH 6M Thermal Control Technology On-board

More information

Fujitsu PRIMERGY BX920 S2 Dual-Socket Server

Fujitsu PRIMERGY BX920 S2 Dual-Socket Server Datasheet Fujitsu PRIMERGY BX920 S2 Dual-Socket Server Blade Datasheet for Red Hat certification Universal Dual-Sockel Server Blade with high computing and I/O performance in a small form factor The PRIMERGY

More information

Cisco MCS 7825-H2 Unified CallManager Appliance

Cisco MCS 7825-H2 Unified CallManager Appliance Cisco MCS 7825-H2 Unified CallManager Appliance This product is no longer being sold and might not be supported. Read the End-of-Life Notice to learn about potential replacement products and information

More information

SIMATIC Field PG M3. SIMATIC Programming device Technical Presentation. For internal use only / Siemens AG 2010. All Rights Reserved.

SIMATIC Field PG M3. SIMATIC Programming device Technical Presentation. For internal use only / Siemens AG 2010. All Rights Reserved. SIMATIC Field PG M3 SIMATIC Programming device Technical Presentation SIMATIC Field PG M3 Perfect for Project engineering Commissioning Service Maintenance Highlights Rugged, high-performance hardware

More information

ThinkServer TS140 - Overview

ThinkServer TS140 - Overview Think TS140 - Overview Version 451, March 2014 1 5 2 6 3 4 7 Front view 1. Optional slim optical + 3.5" drive bay in standard 5.25" bay 2. Optional 3.5" hard drive bay 3. Button 4. Front I/O: 2 USB 3.0

More information

Data Sheet Fujitsu ESPRIMO P2760 Desktop PC

Data Sheet Fujitsu ESPRIMO P2760 Desktop PC Data Sheet Fujitsu ESPRIMO P2760 Desktop PC Your immediately available Office PC The ESPRIMO P2760 is designed for price-conscious customers and is equipped with state-of-the-art Intel technology including

More information

Brainlab Node TM Technical Specifications

Brainlab Node TM Technical Specifications Brainlab Node TM Technical Specifications BRAINLAB NODE TM HP ProLiant DL360p Gen 8 CPU: Chipset: RAM: HDD: RAID: Graphics: LAN: HW Monitoring: Height: Width: Length: Weight: Operating System: 2x Intel

More information

IBM Europe Announcement ZG08-0232, dated March 11, 2008

IBM Europe Announcement ZG08-0232, dated March 11, 2008 IBM Europe Announcement ZG08-0232, dated March 11, 2008 IBM System x3450 servers feature fast Intel Xeon 2.80 GHz/1600 MHz, 3.0 GHz/1600 MHz, both with 12 MB L2, and 3.4 GHz/1600 MHz, with 6 MB L2 processors,

More information

Mini server, BIG performance AC100

Mini server, BIG performance AC100 Mini server, BIG performance AC100 The AC100 is the perfect first server for your small business. This tiny dynamo packs a wealth of enterprise level features including Intel Xeon processors, ECC memory,

More information

Power Redundancy. I/O Connectivity Blade Compatibility KVM Support

Power Redundancy. I/O Connectivity Blade Compatibility KVM Support 1.Blade server Blade Chasis Specification Blade Chassis Form Factor 6U-10U rack mountable Chasis to House at least 6 or more Blade Servers Chasis Should be configured with 6 blades Network Redundancy I/O

More information

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster

More information

Quality, Reliability, Performance

Quality, Reliability, Performance Quality, Reliability, Performance SIMATIC IPC: The More Industrial PC siemens.com/ipc Brochure Edition April 2014 Answers for industry. PC innovations for industry. For almost three decades now, Siemens

More information

Superior PCs ESPRIMO. Windows. Life without Walls. Fujitsu recommends Windows 7. ESPRIMO P7935 E85+ Your expandable workhorse Operating system

Superior PCs ESPRIMO. Windows. Life without Walls. Fujitsu recommends Windows 7. ESPRIMO P7935 E85+ Your expandable workhorse Operating system Superior PCs P7935 E85+ Your expandable workhorse D2812-A2x (µbtx) Intel Q45 Intel Celeron 450, 512 KB, 800 MHz 4 x total II, NCQ and 3 GBit, AHCI, Raid 1/0 business critical 1 x serial (9pin, 16 byte

More information

Embedded PC Systems. DSMcomputer. Listen Advise Solve

Embedded PC Systems. DSMcomputer. Listen Advise Solve Embedded PC Systems DSMcomputer Listen Advise Solve Applications possibilities The exciting applications We have the appropriate embedded system in a compact housing for every application in the industrial

More information

Datasheet. The cost-optimized all-rounder

Datasheet. The cost-optimized all-rounder Datasheet Fujitsu Thin Client The cost-optimized all-rounder The compact and cost-efficient is your perfect entry thin client for Server-Based Computing and Virtual Workplace solutions. High energy-efficiency

More information

SUN FIRE X4170 SERVER

SUN FIRE X4170 SERVER SUN FIRE X4170 SERVER KEY FEATURES AND BENEFITS ULTIMATE IN ENTERPRISE PERFORMANCE FOR DATABASE MANAGEMENT OR WEB APPLICATIONS FEATURES Your business is under increasing pressure to deliver more services

More information

AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM55. 15 ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor with HM55 chipset

AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM55. 15 ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor with HM55 chipset AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM55 15 ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor with HM55 chipset AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM55 15 ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor

More information

Phone and Fax: (717) 762-7444 or Send Email to- [email protected] On the Internet at http://www.rose-computers.com

Phone and Fax: (717) 762-7444 or Send Email to- sam@rose-computers.com On the Internet at http://www.rose-computers.com Rose Computers Custom configured complete systems, upgrades, individual components, and on-site service available. 14789 Wingerton Road Waynesboro, PA 17268 Phone and Fax: (717) 762-7444 or Send Email

More information

Data Sheet ESPRIMO P3510. Your flexible economic PC ESPRIMO P3510

Data Sheet ESPRIMO P3510. Your flexible economic PC ESPRIMO P3510 Pages: Data Sheet Your flexible economic PC Issue: September 2009 The is the right choice for major customers requiring the latest standard features. This Microtower PC is the ultimate balance between

More information

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling High Performance 1U Server The ASUS RS700-E7/RS8 1U server is based on dual Intel Socket R series processors (135W), designed with 24 DIMM slots to support up to 512GB memory. It features an optimized

More information

Data Sheet Fujitsu FUTRO A300 Thin Client

Data Sheet Fujitsu FUTRO A300 Thin Client Data Sheet Fujitsu FUTRO A300 Thin Client Convincing Simplicity Fujitsu s FUTRO A300 is your easy-to-use thin client for highly secure server-based computing or desktop virtualization. It reduces your

More information

New Lenovo IdeaCentre A600 systems with Intel processor technology deliver high-performance computing at a competitive price

New Lenovo IdeaCentre A600 systems with Intel processor technology deliver high-performance computing at a competitive price , dated February 24, 2009 New Lenovo IdeaCentre A600 systems with Intel processor technology deliver high-performance computing at a competitive price Table of contents 1 At a glance 3 Product number 1

More information

Data Sheet Fujitsu ESPRIMO P2560 Desktop PC

Data Sheet Fujitsu ESPRIMO P2560 Desktop PC Data Sheet Fujitsu ESPRIMO P2560 Desktop PC Your immediately available Office PC The ESPRIMO P2560 is designed for price-conscious customers and is equipped with state-of-the-art standard Intel technology.

More information

QuickSpecs. HP 285 Pro G1 Microtower Business PC. Overview

QuickSpecs. HP 285 Pro G1 Microtower Business PC. Overview Overview Front 1. Half-height Bay - supporting an optical disk drive (optional) 2. Power Button 3. PC Status LED 4. (2) USB 2.0 Ports 5. 3.5 mm Microphone Jack 6. 3.5 mm Headphone Output 7. 6-in-1 Media

More information

Datasheet ESPRIMO P3520 E85+ Your flexible economy PC ESPRIMO P3520 E85+

Datasheet ESPRIMO P3520 E85+ Your flexible economy PC ESPRIMO P3520 E85+ Pages: Datasheet ESPRIMO P3520 E85+ Your flexible economy PC Issue: December 2009 ESPRIMO P3520 E85+ The ESPRIMO P3520 is the right choice for major customers requiring the latest standard features. This

More information

Data Sheet FUJITSU TeamPoS 7000 S-Series Model 320 Retail PoS Controller

Data Sheet FUJITSU TeamPoS 7000 S-Series Model 320 Retail PoS Controller Data Sheet FUJITSU TeamPoS 7000 S-Series Model 320 Retail PoS Controller Data Sheet FUJITSU TeamPoS 7000 S-Series Model 320 Retail PoS Controller Small Footprint, high performance, great connectivity and

More information

New levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U

New levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U New levels of efficiency and optimized design As always, ASUS makes servers that deliver superior performance. In this generation, the ASUS RS300-E8-RS4 supports the latest Intel Xeon E3-1200 v3 processor

More information

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware A+ Guide to Managing and Maintaining Your PC, 7e Chapter 1 Introducing Hardware Objectives Learn that a computer requires both hardware and software to work Learn about the many different hardware components

More information

Cisco MCS 7845-I2 Unified Communications Manager Appliance

Cisco MCS 7845-I2 Unified Communications Manager Appliance Cisco MCS 7845-I2 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables

More information

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade clusters are flexible, modular scalable offering a high-density

More information

Data Sheet FUJITSU CELSIUS C620 Workstation

Data Sheet FUJITSU CELSIUS C620 Workstation Data Sheet FUJITSU CELSIUS C620 Workstation Data Sheet FUJITSU CELSIUS C620 Workstation 1U of Pure Workstation Performance If you need maximum workstation performance out of the datacenter, Fujitsu s compact

More information

HQP-1072 Series System User Guide

HQP-1072 Series System User Guide HQP-1072 Series System User Guide Table of Contents HQP-1072 Hardware User Guide...3 1. HQP-1072 system Introduction...4 1.1 Box Contents...4 1.2 Specification...6 1.3 Appearance...8 2. Setting Up...10

More information

Datasheet Fujitsu PRIMERGY RX100 S6 Mono Socket Intel Xeon Rack Server (1U)

Datasheet Fujitsu PRIMERGY RX100 S6 Mono Socket Intel Xeon Rack Server (1U) Datasheet Fujitsu PRIMERGY RX100 S6 Mono Socket Intel Xeon Rack Server (1U) Cost optimized and highly modular multi usage rack server The PRIMERGY RX Rack Server family is the perfect platform to form

More information

Features Rich Expansion. Specifications Dimensions Optional Kit. Packing List Ordering Information Optional Modules

Features Rich Expansion. Specifications Dimensions Optional Kit. Packing List Ordering Information Optional Modules AFL2-W15A-N270/ L325 IEI designed a completely new modular architecture for its new AFOLUX GEN II panel PCs. A variety of expansion module boards connecting through a common interface give it functional

More information

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions Facility Pilot Server Art. No. : FAPV-SERVER-REG Facility Pilot Server Art. No. : FAPVSERVERREGGB Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically

More information

Sun Microsystems Special Promotions for Education and Research January 9, 2007

Sun Microsystems Special Promotions for Education and Research January 9, 2007 Sun Microsystems Special Promotions for Education and Research Solve big problems on a small budget with Sun-Education s trusted partner for cutting-edge technology solutions. Sun solutions help your campus

More information

Data Sheet FUJITSU Server PRIMERGY RX1330 M1 rack server

Data Sheet FUJITSU Server PRIMERGY RX1330 M1 rack server Data Sheet FUJITSU Server PRIMERGY RX1330 M1 rack server Data Sheet FUJITSU Server PRIMERGY RX1330 M1 rack server Small in size and low in cost rich in optional features FUJITSU Server PRIMERGY systems

More information

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project QUESTIONS & ANSWERS ItB tender 72-09: IT Equipment. Elections Project In lot 1, position 1 - Server for Data Base 1. Q: You order Microsoft Windows Server 2008, 64 bit, Enterprise, License with 25 or more

More information

Data Sheet Fujitsu ESPRIMO E400 E85+ Desktop PC

Data Sheet Fujitsu ESPRIMO E400 E85+ Desktop PC Data Sheet Fujitsu ESPRIMO E400 E85+ Desktop PC Your Flexible Economy PC Fujitsu All-round ESPRIMO PCs deliver high-quality computing for your office applications and projects at a very attractive price

More information

Automation Motion Server

Automation Motion Server Automation Motion Server Family of industrial PCs preconfigured with Aerotech s A3200 motion controller Intel i5 and i7 processors Rack or panel-mount versions DVI and HDMI video outputs Optional EtherCAT

More information

TS500-E5. Configuration Guide

TS500-E5. Configuration Guide TS500-E5 Configuration Guide E4631 Second Edition V2 March 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may

More information

VIA Eden 1GHz ULV Processor AFL-07A-CX2. HDD Drive Bay Optional HSDPA Module (support GSM 850,EGSM 900,DCS 1800 & PCS 1900) Mounting

VIA Eden 1GHz ULV Processor AFL-07A-CX2. HDD Drive Bay Optional HSDPA Module (support GSM 850,EGSM 900,DCS 1800 & PCS 1900) Mounting AFOLUX All-in-One Touch Panel PC AFL-07A-CX2 7 Widescreen WVGA Touch Panel PC VIA Eden 1GHz ULV Processor Fanless Fully Integrated I/O AFL-07A-CX2 Power Switch Reset Button The compact fanless AFL-07A-CX2

More information

HUS-IPS-5100S(D)-E (v.4.2)

HUS-IPS-5100S(D)-E (v.4.2) Honeywell s HUS-IPS-5100S(D)-E is a controller-based IP SAN unified storage appliance. Designed for centralized mass data storage, this IP SAN solution can be used with the high performance streaming server

More information