1 Specification Small Form Factor Pluggable Duplex LC Connector SFP Gigabit Optical Transceivers BASE-LX 5Mbit/s Ordering Information KY - SFPS (Temperature Hardened with DDMI) Category SD : DDMI Product Voltage / Temperature : 3.3V / - ~ +85 Model Name Voltage Category Device type Interface SD/LOS Temperature Distance Latch Color KY-SFPSMKG 3.3V With DDMI FP / PIN AC / AC LVTTL km Blue Coupling - C~+85 C 7 SE Willow Place Telephone: (9) Blue Springs, Missouri 6 (86) FAX: (8) Sales@.co Net w o r k s T h a t S erve P e o p l e
2 Features ROHS Compliant Standard Small Form Factor Pluggable Package SFP MSA Compliant Digital Diagnostic SFF-87 Rev.. Compliant Gigabit Ethernet Standard ( IEEE8.3Z BASE-LX ) Compliant Fibre Channel Standard ( -SM-LC-L ) Compliant Laser Class Product IEC685- Compliant Standard Duplex LC Receptacle Optical Interface Single V Power Supply Differential LVPECL Data Input and Output LVTTL Loss of Signal Serial ID through I C Interface Low Power Consumption Absolute Maximum Ratings Parameter Symbol Min Typ Max Unit Storage temperature TS - 85 C Supply voltage VCC V Operating Relative Humidity % Input voltage VIN V CC V Operating Conditions Parameter Symbol Min Typ Max Unit Supply Voltage VCC V Operating Case temperature ( TSD-SCA-G ) Tc - 7 Operating Case temperature ( TSD-SCA-G ) - 85 ºC Total Current ( Transmitter + Receiver ) Icc ma 7 SE Willow Place Telephone: (9) Blue Springs, Missouri 6 (86) FAX: (8) Sales@.co
3 Transmitter Specifications ( V CC =3.V~3.5V;Tc= o C~7 o C / Tc= - o C~85 o C ) Parameter Symbol Min Typ Max Unit Optical Characteristics Output Optical Power Pout dbm Extinction Ratio ER db Center Wavelength λ C nm Spectral Width (RMS) σ nm Rise/Fall time (-8%) T r,f ps Relative Intensity Noise Output Eye Compliant with IEEE 8.3z RIN db/hz Max. P out TX-DISABLE Asserted P OFF dbm Electrical Characteristics Differential Input Voltage VDIFF. --. V Tx_Disable_Input_High VDISH. -- V CC +.3 V Tx_Disable_Input_Low VDISL --.8 V Tx_Fault_Output_High VFH. -- V CC +.3 V Tx_Fault_Output_Low VFL --.8 V Receiver Specifications ( V CC =3.V~3.5V;Tc= o C~7 o C / Tc= - o C~85 o C ) Parameter Symbol Min Typ Max Unit Optical Characteristics Optical Input Power-maximum P SATIN dbm Receiver Sensitivity ( PRBS= 7 -;BER - ) P SEN dbm Operating Center Wavelength λ c 6 6 nm Optical Return Loss ORL db Loss of Signal De-asserted PLD dbm Loss of Signal - Asserted PLA dbm Loss of Signal - Hysteresis PLH.5 6 db Electrical Characteristics Differential Output Voltage VDIFF. --. V Receiver Loss of Signal Output Voltage -Low V LOSH --.8 V Receiver Loss of Signal Output Voltage -High V LOSL -- V CC +.3 V 7 SE Willow Place Telephone: (9) Blue Springs, Missouri 6 (86) FAX: (8) Sales@.co
4 Pin Definition and Descriptions Pin Name Input/Output Level Description VeeT Input Transmitter ground TXFault Output/LVTTL Laser failure indication. High level indicates laser failure. Externally pulled up 3 TXDisable Input/LVTTL Transmitter disable, High signal/open disables TX laser output. Low level enables TX output, internally pulled up. MOD-DEF() Input/output Module definition, SDA, Data line for IC bus. Externally pulled up 5 MOD-DEF() Input Module definition, SCL, Clock for IC bus. Externally pulled up 6 MOD-DEF() Output Module definition, Module present. Ground inside module. 7 Rate Select - No connection. 8 LOS Output/LVTTL 9 VeeR Input Receiver ground VeeR Input Receiver ground VeeR Input Receiver ground Receiver loss of signal indication. Low signal indicates optical signal is present at RX input. Should be Externally pulled up. RD - Output/LVPECL Inverted receiver data output (AC coupled) 3 RD + Output/LVTTL Non-inverted receiver data output (AC coupled) VeeR Input Receiver ground 5 VccR Input Receiver power supply 6 VccT Input Transmitter power supply 7 VeeT Input Transmitter ground 8 TD + Input/LVPECL non-inverted transmitter data input (AC coupled) 9 TD - Input/LVPECL Inverted transmitter data input (AC coupled) VeeT Input Transmitter ground 7 SE Willow Place Telephone: (9) Blue Springs, Missouri 6 (86) FAX: (8) Sales@.co
5 Recommended Circuit Diagram VccT to KΩ VeeT TxDisable 3,7, 3.3V to KΩ TxFault Laser Diode Laser Diode Driver Ω TD+ TD- 8 9 VccT 6 µη 3.3V.µF.µF µf VccR 5 µη SerDes IC Photo Diode RD - µf.µf Protocol IC Limiting Amplifier RD+ 3 Ω TIA LOS 8 3.3V to KΩ to KΩ to KΩ to KΩ MOD-DEF MCU AH / AH MOD-DEF 5 MOD-DEF 6 PLD/PAL SFP Transceiver VeeR 9,,, System 7 SE Willow Place Telephone: (9) Blue Springs, Missouri 6 (86) FAX: (8) Sales@.co
6 Content in -Wire Address AH Address ~ ~ 39 ~ ~ 59 6 ~ ~ 83 8 ~ 89 9 ~ ~7 HEX Name of Field 3 Identifier Extended Identifier 7 Connector type Infiniband Compliance Codes SONET Compliance Codes SONET Compliance Codes Ethernet Compliance Codes Fiber Channel link length Fiber Channel transmitter technology Fiber Channel transmission media Fiber Channel speed Encoding codes: D Nominal Bit Rate (units of Mbps) Rate identifier Link length supported for 9um fiber C8 Link length supported for 9um fiber Link length supported for 5um,OM Link length supported for 6.5um,OM Link length supported for copper Link length supported for 5um,OM3 6,F,5,D,5,5,9,3 Vendor Name,,F,5,,,,, Unallocated,, Vendor OUI 5,53,,D,53,3(3),3,,3, Part Number D,7,3,3,,,,,, Vendor Revision number 5,E Laser Wavelength Unallocated CC_BASE: Options A Options Bit Rate, max. Bit Rate, min. Serial Number Serial Number yy/mm/dd Date Code, Vendor specific lot code 68 Diagnostic Monitoring Type B Enhanced Options (soft) 3 SFF-87 Compliance CC_EXT Vendor specific 7 SE Willow Place Blue Springs, Missouri 6 Description SFP SFP LC Not compliant Not compliant Not compliant BASE-LX LC / Long Distance N/A Single Mode MBytes/sec 8B/B 3Mbps (units of km) (units of m) N/A (units of m) N/A(units of m) N/A (units of m) N/A (units of m) FORMERICAOE TSD-S()CA-G 3nm Check sum of byte ~ 6 TX-DIS, TX_FAULT, RX-LOS Internal calibration All flags, TX_FAULT, RX-LOS Rev. Check sum of byte 6 ~ 9 Telephone: (9) (86) FAX: (8) Sales@.co
7 Content in -Wire Address AH Add Bytes Name Hex Real Value Temp High Alarm* Temp Low Alarm* Temp High Warning* Temp Low Warning* Voltage High Alarm Voltage Low Alarm Voltage High Warning Voltage Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm TX Power Low Alarm TX Power High Warning TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power High Warning RX Power Low Warning Reserved RX_PWR() RX_PWR(3) RX_PWR() RX_PWR() RX_PWR() TX_I(Slope) TX_I(Offset) TX_PWR(Slope) TX_PWR(Offset) T(Slope) T(Offset) V(Slope) V(Offset) Reserved Checksum 55 (6) (D8) 5 (5F) A (E) 8CA B8 798 AFC8 9C 9C DAC DF 63 3D 9D F F8 85 ( ) (- ) 8 (95 ) (-3 ) 3.6V 3.V 3.5V 3.V 9mA 5mA 8mA 7mA 3dBm -8dBm dbm -6dBm -dbm -5dBm -3dBm -3dBm - Note *: ( ) for TSD-SCA-G. 7 SE Willow Place Blue Springs, Missouri 6 Telephone: (9) (86) FAX: (8) Sales@.co
8 Mechanical Outlines ( Unit : mm) 7 SE Willow Place Telephone: (9) Blue Springs, Missouri 6 (86) FAX: (8) Sales@.co
SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX 1.0625Gb/s Fiber Channel
Product Features Compliant to IEEE Std 802.3-2005 Gigabit Ethernet 1000Base-SX, with DOM Specifications according to SFF-8074i and SFF-8472, revision 9.5 Digital Diagnostic Monitoring 850nm Vertical Cavity
More information2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX
2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX Features Support 2.488Gbps data links 1490nm DFB laser and PIN photodetector for 20km transmission 2xBi-directional transceivers
More information155Mbps DFB SFP Optical Transceiver, 120km Reach
155Mbps DFB SFP Optical Transceiver, 120km Reach Features Data-rate of 155Mbps operation DFB 1550nm wavelengths laser and PIN photo detector for 120km transmission Compliant with SFP MSA and SFF-8472 with
More informationHow To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (
Features 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX Supports 9.95Gb/s to 10.3Gb/s data rates Simplex LC Connector Bi-Directional SFP+ Optical Transceiver Single
More information155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX
Features 155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX 1310nm FP laser and PIN photodetector for 40km transmission Compliant with SFP MSA and SFF-8472 with simplex
More information8.5Gb/s SFP+ Fibre Channel Optical Transceiver
8.5Gb/s SFP+ Fibre Channel Optical Transceiver Features Up to 8.5Gb/s bi-directional data links Hot Pluggable SFP+ footprint Built-in digital diagnostic functions 1310nm FP laser transmitter Duplex LC
More informationSFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver
Product Features Up to 1.25Gb/s bi-directional data links SFP form with compact RJ-45 connector +3.3V single power supply 0 to 70 o C operating case temperature Intelligent Auto-Negotiation support for
More informationProduct Specification 10Gb/s BIDI SFP+ Transceiver
PRODUCT FEATURES Up to 10.7Gbps Data Links Product Specification 10Gb/s BIDI SFP+ Transceiver Single Mode LC Receptacle Bi-directional Transceiver Up to 20km transmission on SMF Power dissipation
More informationSFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW
Product Features Compliant with IEEE Std 802.3-2005 10G Ethernet 10GBase-LR/LW Electrical interface specifications per SFF-8431 Management interface specifications per SFF-8431 and SFF-8472 SFP+ MSA package
More informationDWDM SFP Series. Power budget* (note2) Laser
EOLS-1606-XXD Series SFP Single-Mode for DWDM Application Duplex SFP Transceiver Digital Diagnostic Function RoHS6 Compliant Features Operating Data Rate up to 622Mbps Available in all C-Band Wavelengths
More informationProduct Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL
Product Specification OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver FTLF1422P1xTL PRODUCT FEATURES 622 Mb/s bi-directional data links Hot-pluggable SFP footprint Built-in digital diagnostic
More information4.25Gbps SFP Optical Transceiver, 30km Reach
4.25Gbps SFP Optical Transceiver, 30km Reach Features Single 3.3 V supply Supports 1.0625/2.125/4.25Gb/s Fiber Channel Operation Gigabit Ethernet compatible 1310nm DFB Laser SFP MSA SFF-8074i compliant
More informationDWDM SFP Series. Power budget* (note2) Laser
EOLS-1624-XXD Series SFP Single-Mode for DWDM Application Duplex SFP Transceiver Digital Diagnostic Function RoHS6 Compliant Features Operating Data Rate up to 2.5Gbps Available in all C-Band Wavelengths
More informationSFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609
Features Applications 10 Gigabit Ethernet (10.3125Gbps) 10 Gigabit Fiber Channel (10.51875Gbps) SFP+ Type DWDM Dual LC Transceiver EML Laser PIN Photo Detector 40Km transmission with SMF 3.3V dual power
More informationDTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver
产 品 规 格 书 Product Specification Sheet DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver PRODUCT FEATURES Up to 1.25Gb/s data links FP laser transmitter for DTSB35(53)12L-CD20
More informationGPON OLT Optical Transceiver SFP Module RTXM167-526. Features
GPON OLT Optical Transceiver SFP Module RTXM167-526 Features Integrated Single fiber bi-directional optical subassembly 1310nm Burst-mode APD/TIA receiver and 1490nm Continuous DFB laser Transmitter (with
More information1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet
1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet 3.3V: GBIC-1250A4FS (500m) GBIC-1250B4QS (10km) 5V: GBIC-1250A3FS (500m) GBIC-1250B3QS (10km) Features Compliant with
More informationLONGLINE 10Gbps 10km SFP+ Optical Transceiver
LONGLINE 10Gbps 10km SFP+ Optical Transceiver Features Optical interface compliant to IEEE 802.3ae 10GBASE-LR Electrical interface compliant to SFF-8431 Hot Pluggable 1310nm DFB transmitter, PIN photo-detector
More information10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance
Feature 10Gb/s serial optical interface compliant to 802.3aq 10GBASE-LRM Electrical interface compliant to SFF-8431 specifications for enhanced 8.5 and 10 Gigabit small form factor pluggable module SFP+
More information1.25Gbps GBIC Optical Transceiver, 20km Reach
1.25Gbps GBIC Optical Transceiver, 20km Reach Features Dual data-rate of 1.25Gbps/1.0625Gbps operation 1310nm FP laser and PIN photodetector for 20km transmission Duplex SC optical interface Standard serial
More informationProduct Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL
Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL PRODUCT FEATURES Hot-pluggable XFP footprint Supports 8.5Gb/s and 9.95 through 10.5Gb/s* bit
More informationProduto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet
Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet Features Dual data-rate of 1.25Gbps/1.063Gbps operation 1550nm DFB
More informationLONGLINE 40km XFP Optical Transceiver
LONGLINE 40km XFP Optical Transceiver Features XFP MSA Rev 4.5 Compliant Data rate from 9.95Gbps to 11.3Gbps No Reference Clock required Cooled 1550nm EML and PIN receiver link length up to 40km +1.8V,+3.3V,+5V
More informationProduct Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL
Finisar Product Specification 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL Product Features Up to 1.25Gb/s bi-directional data links Hot-pluggable SFP
More informationRoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet
RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet Features Compatible with specifications for IEEE 802.3ab/Gigabit Ethernet Compliant with MSA specifications for
More information10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application
Features Compliant with IEEE 802.3u standard Link distance at 100Mbps: up to 100m per IEEE802.3 EEPROM with serial ID functionality Detailed product information in EEPROM Industry standard small form pluggable
More informationXFP Optical Receiver, 80km Reach
Features Supports 9.95Gb/s to 11.1Gb/s bit rates Hot-pluggable XFP footprint Maximum link length of 80km with SMF APD ROSA receiver XFP MSA package with duplex LC connector No reference clock required
More information10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX
Features 10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX Supports 9.95Gb/s to 10.5Gb/s bit rates Hot-pluggable XFP footprint Maximum link length of 10km with SMF 1270/1330nm
More informationGBIC CWDM 40km Part no: 70257-70264
GBIC CWDM 40km Part no: 7025770264 Description General The GBIC CWDM 40 transceiver is small form factor pluggable module with standard SC duplex connector for fiber communications. This module is designed
More information10/100/1000BASE-T SFP Transceiver
10/100/1000BASE-T SFP Transceiver Features Support 10/100/1000BASE-T operation in host systems with SGMII interface Up to 1.25Gbps bi-direction data links Hot-pluggable SFP footprint Fully metallic enclosure
More informationEPON ONU Optical Transceiver SFF Module
Features Integrated Single fiber bi-directional optical subassembly 1310nm DFB FP laser Burst-mode Transmitter and 1490nm PIN Continuous APD Continuous receiver(with WDM) receiver(with WDM) SFF 2 10 metallic
More informationRoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber Channel AGM731F
350 E. Plumeria Drive San Jose, CA 95134-1911 USA 1-888-NETGEAR (638-4327) E-mail: info@netgear.com www.netgear.com RoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber
More informationLONGLINE 2km XFP Optical Transceiver
LONGLINE 2km XFP Optical Transceiver Features Supports 9.95Gb/s to 11.1Gb/s bit rates Hot-pluggable XFP footprint Maximum link length of 2km with SMF 1310nm FP laser XFP MSA package with duplex LC connector
More informationSFP-GIG-SX 1000BASE-SX, Jusqu à 550 mètres de distance opérationnelle, Longueur d onde Laser 850nm, Fibre Multimode (MMF), SFP Optique Insérable
SFP-GIG-SX 1000BASE-SX, Jusqu à 550 mètres de distance opérationnelle, Longueur d onde Laser 850nm, Fibre Multimode (MMF), SFP Optique Insérable Caractéristiques: Débit Data jusqu à 1.25Gbps Transmetteur
More information1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver
1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver Features Up to 1.25Gb/s bi-directional data links Hot-pluggable SFP footprint TX Disable and RX Los/without Los function Fully metallic enclosure
More information10GBASE-LR XFP Optical Transceiver AXM752
350 E. Plumeria Drive San Jose, CA 95134-1911 USA 1-888-NETGEAR (638-4327) E-mail: info@netgear.com www.netgear.com 10GBASE-LR XFP Optical Transceiver AXM752 10GBASE-LR XFP Optical Transceiver Pb FEATURES
More informationMethode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT. www.methode.com
DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT QSFP+ MSA compliant Hot-pluggable footprint Supports Digital Serial ID and User Memory Robust Die Cast Housing Small footprint to maximize port spacing
More informationFast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics
Fast Ethernet 00BASE-0 SFP Single Mode Transceivers with Digital Diagnostics TXAGM Single Mode Product Description The TXAGM SFP series of multi-rate fiber optic transceivers with integrated digital diagnostics
More informationPart No. Data Rate Wavelength Interface Temp. DDMI
EOLS-BI1612-10-CL XX Series EOLS-BI1612-10-LC XX Series Single-Mode 100Mbps to 1.25Gbps FE/GBE /FC SC/LC Single-Fiber SFP Transceiver RoHS6 Compliant Features Support 1.25Gbps Data Links A type: 1310nm
More information10GBASE-SR XFP Optical Transceiver AXM751
350 E. Plumeria Drive San Jose, CA 95134-1911 USA 1-888-NETGEAR (638-4327) E-mail: info@netgear.com www.netgear.com 10GBASE-SR XFP Optical Transceiver AXM751 10GBASE-SR XFP Optical Transceiver FEATURES
More informationSFP Copper Transceiver 10/100/1000Base-T
FEATURES / BENEFITS Designed with Broadcom s BCM54616S chipset (login at https://support.broadcom.com/core/login.aspx for IC support) Complies with IEEE 802.3, 802.3u, and 802.3ab specifications Conforms
More informationLONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13
LONGLINE QSFP+ SR4 Features 4 channels full-duplex transceiver modules Transmission data rate up to 10.5Gbps per channel 4 channels 850nm VCSEL array 4 channels PIN photo detector array Low power consumption
More informationSO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.
SO-QSFP28-LR4 QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW The SO-QSFP28-LR4 is a 100 Gbps transceiver module designed for optical communication applications compliant to 100GBASE-LR4 of
More informationIntel Ethernet SFP+ Optics
Product Brief Intel Ethernet SFP+ Optics Network Connectivity Intel Ethernet SFP+ Optics SR and LR Optics for the Intel Ethernet Server Adapter X520 Family Hot-pluggable SFP+ footprint Supports rate selectable
More informationDual Fiber SFP Series
SFP-ZX, EZX and XZX series SFP Single-Mode, Dual Fiber Transceiver for 1.25Gbps FC/GBE Features Up to 4.25Gbps Data Rate 1550nm DFB 80km with 9/125 µm SMF 120km with 9/125 µm SMF 160km with 9/125 µm SMF
More informationProduct Specification. +3200 ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx
Product Specification +3200 ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx PRODUCT FEATURES Supports 10.7Gb/s to 11.35Gb/s -500 to +3200 ps/nm Dispersion Tolerance (~200km reach without dispersion
More information10GBASE -LRM, 220m Reach GX2-31192-LRMC
Features Compatible with X2 MSA Rev2.0b 10GBASE -LRM, 220m Reach GX2-31192-LRMC Support of IEEE 802.3ae 10GBASE-LR at 10.3125Gbps Transmission Distance up to 220m(MMF) SC Receptacle 1310nm DFB Laser SC
More informationRoHS compliant 1310 nm multi-mode Transceiver (2 km) 1x9, ST Duplex Plastic Connector, 3.3 V 155 Mbps ATM/ Fast Ethernet
Features RoHS compliant Industry standard 1 9 footprint ST duplex connector Single power supply 3.3 V Differential LVPECL inputs and outputs Compatible with solder and aqueous wash processes Class 1 laser
More information1000BASE-BX-OLT Transceiver
SFP BIDI, Single LC Connector, 1490nm DFB LD for Single Mode Fiber, ohs Compliant Features 1490nm DFB LD Multi Data ate: from 125M to 1.25Gbps, NZ Single +3.3V Power Supply ohs Compliant and Lead-free
More informationModultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description
Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description Modultech OTN XFP DWDM transceiver combines carrier grade OTN G.709 and FEC performance into a XFP MSA
More informationX2 LR Optical Transponder, 10Km Reach
X2 LR Optical Transponder, 10Km Reach Features Compatible with X2 MSA Rev2.0b Support of IEEE 802.3ae 10GBASE-LR at 10.3125Gbps Transmission Distance up to 10km(SMF) SC Receptacle 1310nm DFB Laser SC Duplex
More information155Mbps ATM-Single Mode Transceiver
SFP, Duplex LC Connector, 1310nm FP LD for Single Mode Fiber, ohs Compliant Features 1310nm FP LD Data ate: 155Mbps, NZ Single +3.3V Power Supply ohs Compliant and Lead-free AC/AC Differential Electrical
More informationMethode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly. www.methode.com
DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly Compliant with Infiniband Architecture Specification Annex 6 Hot-pluggable footprint Supports Serial ID (write protected) Robust Die Cast Housing
More informationSO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION
SO-CFP-ER4-DWDM CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20 km SO-CFP-ER4-DWDM OVERVIEW The SO-CFP-ER4-DWDM is a 100G transceiver module supporting 100GBASE-LR4 and OTU4 applications over singlemode (SM)
More informationPART NUMBER INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE
Features Compliant with 10GFC 1200-MX-SN-I Fiber Channel standard Compliant with IEEE802.3ae 10GBASE-SW/SR Ethernet standard Compliant with XFP MSA INF-8077i SONET OC-192/SDH STM-64 application Differential
More informationDispersion penalty test 1550 Serial
Dispersion penalty test 1550 Serial Peter Öhlen & Krister Fröjdh Optillion Irvine, January 2001 Dispersion penalty test, 1550 serial Page 1 SMF Transmission at 1550 nm Different from multi-mode transmission
More informationCisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories
Data Sheet Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories Easily Connect Switches with Fiber Optic Networking Modules Highlights Adds fiber-optic connectivity to Cisco Small
More informationApplication Note 5016
Digital Diagnostic Monitoring Interface (DMI) on Avago Enterprise and Storage Fiber Optic Transceivers: Applications and Implementation Application Note 5016 Introduction The present application note describes
More informationCISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:
DATA SHEET CISCO DWDM XENPAK OVERVIEW The Cisco Dense Wavelength-Division Multiplexing (DWDM) XENPAK pluggable allows enterprise companies and service providers to provide scalable and easy-to-deploy 10
More informationAccurate Loss-of-Signal Detection in 10Gbps Optical Receivers using the MAX3991
Design Note: HFDN-34.0 Rev.1; 04/08 Accurate Loss-of-Signal Detection in 10Gbps Optical Receivers using the MAX3991 Functional Diagrams Pin Configurations appear at end of data sheet. Functional Diagrams
More informationFiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V
Fiber Optics Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 Features Bipolar IC with open-collector output Digital output, TTL compatible Sensitive in visible
More informationTools for Building a Better Network
Tools for Building a Better Network Key Differentiator NetVanta Cable/SFP Diagnostics Increasing Productivity with Network Diagnostics As businesses continue to make the most out of every available resource,
More informationSerial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC
Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC John Crow,, IBM Watson Research Center, jdcrow@us.ibm.com Dan Kuchta,, IBM Watson Research Center, kuchta@us.ibm.com Mounir Meghelli,,
More informationCisco SFP Optics for Gigabit Ethernet Applications
Cisco SFP Optics for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output device that plugs into a Gigabit
More informationHARTING econ 3000 Introduction and features
HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications
More informationGolden test for dispersion penalty 1550 Serial
Golden test for dispersion penalty 1550 Serial Peter Öhlen, Krister Fröjdh (Optillion) Tampa, November 2000 Golden test for dispersion penalty, 1550 serial Page 1 SMF Transmission at 1550 nm Different
More informationHARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
More informationWhite Paper. Fiber Optics in Solar Energy Applications. By Alek Indra. Introduction. Solar Power Generation
s in Solar Energy Applications White Paper By Alek Indra Introduction Solar energy has recently become a popular alternative energy source to meet demands around the world due to the fluctuation of oil/coal
More informationPublished SFF-8472 Rev 12.2. SFF Committee SFF-8472. Specification for. Diagnostic Monitoring Interface for Optical Transceivers
SFF Committee documentation may be purchased in hard copy or electronic form SFF specifications are available at ftp://ftp.seagate.com/sff SFF Committee SFF-8472 Specification for Diagnostic Monitoring
More information050-123 BF15U2-2570. REV DESCRIPTION DATE APPROVED 2 Preliminary 1/7/2016 RAS/MF
Copper to Fiber Single Channel Ethernet Media Converter 10/100/1000BASE-T to Single Fiber 1310/1550 Bidirectional Optical Ethernet 28VDC M38999 (Signal), M38999 (Power), M38999 (Fiber Optic) REV DESCRIPTION
More informationPrisma IP 10 GbE VOD Line Card
Digital Transport Prisma IP 10 GbE VOD Line Card Description The Prisma IP 10 GbE Line Card family of products consists of Transmitter (OTX), Receiver (ORX), and Transceiver (OTR) modules. These modules
More informationDS1621 Digital Thermometer and Thermostat
Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent
More informationFEATURES DESCRIPTION APPLICATIONS BLOCK DIAGRAM. PT2248 Infrared Remote Control Transmitter
Infrared Remote Control Transmitter DESCRIPTION PT2248 is an infrared remote control transmitter utilizing CMOS Technology. It is capable of 18 functions and a total of 75 commands. Single-shot and continuous
More informationCisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications
Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output
More informationDisplayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters
Description Displayport combines the audio and video through an interface. It supports high resolution displays and multiple displays with a single cable, and increases the efficiency and bandwidth of
More informationSpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II
BLUE SKY RESEARCH The SpectraTec II, two wavelength laser module is a highly integrated system comprised of two lasers, individual driving and temperature control electronics, wavelength combining, and
More informationDS1621 Digital Thermometer and Thermostat
www.maxim-ic.com FEATURES Temperature measurements require no external components Measures temperatures from -55 C to +125 C in 0.5 C increments. Fahrenheit equivalent is -67 F to 257 F in 0.9 F increments
More information76-77 GHz RF Transmitter Front-end for W-band Radar Applications
Freescale Semiconductor Data Sheet Summary for MC33 7-77 GHz RF Transmitter Front-end for W-band Radar Applications The MR2001 is a scalable three package solution for automotive radar modules. The chipset
More informationHow To Get A Better Signal From A Fiber To A Coax Cable
Gigabit Transmission What s the Limit? Fanny Mlinarsky Page 1 What s the Limit? Speed Faster higher frequency higher attenuation less headroom Distance Longer higher attenuation more jitter less headroom
More information7 OUT1 8 OUT2 9 OUT3 10 OUT4 11 OUT5 12 OUT6 13 OUT7 14 OUT8 15 OUT9 16 OUT10 17 OUT11 18 OUT12 19 OUT13 20 OUT14 21 OUT15 22 OUT16 OUT17 23 OUT18
18 CHANNELS LED DRIVER GENERAL DESCRIPTION IS31FL3218 is comprised of 18 constant current channels each with independent PWM control, designed for driving LEDs. The output current of each channel can be
More informationWaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor
WaveReady CFM Optical Link Monitoring System: Continuous Fiber Monitor www.lumentum.com Data Sheet The Lumentum Continuous Fiber Monitor (CFM) offers a compact, modular solution for performance monitoring
More informationDVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters
Description DVI (Digital Visual Interface) recently becomes an popular interface between monitor and PC. Electrical signal limits the transmission length and quality. APAC DVI extender helps DVI to transmit
More informationLigent intelligent photonics. a global leader in transceiver technology
intelligent photonics a global leader in transceiver technology 2009 Forward igent Photonics, Incorporated, a St. Charles, Illinois based U.S. Corporation is a world-class supplier of optical transceivers
More informationDM/SP7041-X 1000BASE-T
DM/SP7041-X 1000BASE-T Small Form Factor Pluggable Module Specification and Design Verification Test Table of Contents Table of Contents...2 List of Figures...2 List of Tables...2 1. Scope...3 2. Product
More informationTrends In Data Rate And Link Length In Evolving Optical Standards
Trends In Data Rate And Link Length In Evolving Optical Standards David Cunningham 22 nd September 2013 Outline Building and Data Centre link lengths Trends for standards-based electrical interfaces Data
More informationPhotolink- Fiber Optic Receiver PLR135/T1
Features High PD sensitivity optimized for red light Data : NRZ signal Low power consumption for extended battery life Built-in threshold control for improved noise Margin The product itself will remain
More information3G-SDI/HD-SDI/SD-SDI Electric to Optical Converter EO3G-200
3G-SDI/HD-SDI/SD-SDI Electric to Optical Converter EO3G-200 1. Abstract Electric to Optical Converter for 3G-SDI / HD-SDI / SD-SDI digital video signal Recommended to install in CANARE 161UPSC / 6PSC converter
More informationFiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
More informationUncompromising Integrity. Making 100Gb/s deployments as easy as 10Gb/s
Uncompromising Integrity Making 100Gb/s deployments as easy as 10Gb/s Supporting Data Rates up to 100Gb/s Mellanox 100Gb/s LinkX cables and transceivers make 100Gb/s deployments as easy as 10Gb/s. A wide
More informationData Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers
HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers Data Sheet SERCOS SERCOS is a SErial Realtime COmmunication System, a standard digital interface for communication between controls and drives
More informationHDO700 P FIBRE OPTIC TRANSMITTER
Timo Rantanen 18.1.2011 1(5) HDO700 P FIBRE OPTIC TRANSMITTER HDO700 P is a high performance, extremely linear externally modulated 1550 nm transmitter for HDO fibre optic CATV link. This transmitter type
More informationNC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
More information155 Mb/s Fiber Optic Light to Logic Receivers for OC3/STM1
155 Mb/s Fiber Optic Light to Logic Receivers for OC3/STM1 Application Note 1125 RCV1551, RGR1551 Introduction This application note details the operation and usage of the RCV1551 and RGR1551 Light to
More informationEDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions
EDR-G903 Series Industrial Gigabit Firewall/VPN secure router Router/Firewall/VPN* all-in-one High performance Gigabit copper/fiber combo port WAN redundancy function with 2 WAN interfaces and 1 LAN interface
More informationCISCO 10GBASE X2 MODULES
DATA SHEET CISCO 10GBASE X2 MODULES Figure 1. Cisco 10GBASE X2 and Xenpak Module PRODUCT OVERVIEW The Cisco 10GBASE X2 modules (Figure 1) offers customers a wide variety of 10 Gigabit Ethernet connectivity
More informationSPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY PART NUMBER: MGD1602B DATE: MAR. 17,2004 1.0 MECHANICAL SPECS 1. Overall Module Size 84.0mm(W) x 44.0mm(H) x max 13.5mm(D) for LED backlight version 84.0mm(W)
More informationBV-10 Performance Endpoint Unit PERFORMANCE DEMARCATION FOR NETWORK-WIDE VISIBILITY
PERFORMANCE DEMARCATION FOR NETWORK-WIDE VISIBILITY Highly cost-effective Ethernet performance monitoring device providing complete network visibility for mobile backhaul, Carrier Ethernet and PTN networks
More informationDVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters
Description DVI (Digital Visual Interface) recently becomes an popular interface between monitor and PC. Electrical signal limits the transmission length and quality. APAC DVI extender helps DVI to transmit
More informationNTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
More information