Emergency Power-Off System
|
|
|
- Ira Wilcox
- 9 years ago
- Views:
Transcription
1 Emergency Power-Off System The Emergency Power-Off (EPO) System consists of one or more wall-mounted, push-button EPO boxes. Each EPO box provides a single point of equipment shutdown for up to eight APC InfraStruXure devices and one third-party device (such as an upstream breaker), using normally open (NO) contact closure connections. An EPO box may be cascaded with other EPO boxes to support multiple points of equipment shutdown. See page 13 for a listing of InfraStruXure Devices that are currently compatible with this system. Although designed specifically for InfraStruXure products, the EPO system can be used for tripping any devices that fall within its parameters. See Specifications on page 16 to confirm proper application, and install according to the instructions in this manual. See also For more information about emergency power-off, see white paper #22, Understanding Emergency Power Off (EPO), on the APC Web site (
2 Contents Overview Safety EPO box components Installation Open the EPO System box Mount the system on a wall Connect devices to the EPO box Mount additional EPO boxes Cascading multiple EPO boxes Direct wiring alternative Verify connections at each EPO box Operation APC InfraStruXure Devices Mounting Hole Template Wiring Diagram Specifications Warranty and Service Limited warranty Warranty limitations Obtaining service EPO System Installation and Operation i
3
4 Overview Safety Save these instructions. This manual contains important instructions that should be followed during installation and maintenance of the system. Safety instructions for North America and Canada Electrical Hazard Caution Only a certified electrician can install the system and the wiring to the products it controls. Wiring from the system to the products it controls can either be installed in conduit or installed without conduit if the wires are in accordance with Article 725 of the National Electrical Code (NFPA 70) and Section 16 of the Canadian Electrical Code (C22.1). Only Class 2 circuits rated 30 V or less shall be connected to terminals 1 8. Class 2 circuits are defined in Article 725 of the National Electrical Code (NFPA 70) and Section 16 of the Canadian Electrical Code (C22.1). A Class 2 circuit is a source having limited voltage and energy capacity as follows: a. If an Inherently Limited Power Source, voltage is limited to 30 VAC or 30 VDC, and energy is limited to 8 A. b. If not an Inherently Limited Power Source, voltage is limited to 30 VAC or 30 VDC, energy is limited to 250 VA, and current is limited to 1000/Vmax. The fuse is limited to 5 A if maximum voltage is 20 V, or 100/Vmax if voltage is greater than 20 V but less than 30 V. EPO System Installation and Operation 1
5 Overview Safety instructions for Europe, Middle East, and Africa Electrical Hazard Caution Only a certified electrician can install the system and the wiring to the products it controls. Wiring from the system to the products it controls can either be installed in conduit or without conduit if the wires are in accordance with IEC/EN or equivalent local electric code. EPO can be achived with either a contact closure or application of an external 24VAC or 24VDC from a SELV or PELV source. It is important to note that hazardous voltage from the Mains voltage must be isolated from the contact closure or 24VAC, 24VDC. The EPO circuit contact closure, the 24VAC, or the 24VDC are considered a SELV circuit as defined in EN60950 Safety of Information Technology Equipment or PELV circuit as defined in IECDD Electrical Installations of Buildings Protection for Safety Protection Against Electric Shock. SELV is an abbreviation for Safety Extra Low Voltage. PELV is an abbreviation for Protective Extra Low Voltage. SELV and PELV circuits are isolated from the Mains through a safety isolating transformer, and designed so that under normal conditions the voltage is limited to 42.4Vpeak or 60VDC. 2 EPO System Installation and Operation
6 Overview EPO box components! Flag $ " Button # Shield $ Knock-outs % Mounting holes # " & ' Blanking panels Wire anchors! ( Auxiliary device terminal % ) InfraStruXure device terminal block * Cascading jacks + Wiring check points, Ground stud - Cable clamps & ' ( ) * - +, Wiring, conduit, and mounting hardware are not provided. EPO System Installation and Operation 3
7 Installation Open the EPO System box Remove the screws on the side of the box and open. Keep the screws for after the system is installed. The box will not close securely without the screws in place. Mount the system on a wall Mount the system in a readily-accessible area, on a wall near the principal entrance doors, according to NEC articles and , IEC/EN , or equivalent local regulation. There are two different procedures for mounting the system, depending on if you are running conduit along the wall (page 4) or behind the wall (page 5). In countries where conduit is not used, run the cables from the connected devices or the cascaded EPO boxes directly to the EPO using Shielding Troughs and Cable Ladders. 4 EPO System Installation and Operation
8 Installation If you are running conduit (or cables) along the wall. 1. Use four ¼-inch (6.35-millimeter) screws and fasten the screws through the four mounting holes at each corner of the EPO box and into the wall. (See page 14 for a template.) 2. Run the conduit (or cables for the connected devices) to the EPO box. The conduit will contain all wiring from the connected devices and all cascading cables. The knockouts in the top and bottom of the EPO box accept.- (13-) and /-(19-) inch (millimenter) conduit or clusters of cables. Remove the knockouts required for your installation. When planning your conduit requirements, consider that two cascading cables will fit in.-inch (13-millimeter) conduit and four cascading cables will fit in /-inch (19- millimeter) conduit. See Cascading multiple EPO boxes on page 8 for more information. 3. Install an appropriate fitting with a lock-nut for each knockout that you are using. 4. Connect your conduit (or cables) to the fittings. EPO System Installation and Operation 5
9 Installation IIf you are running conduit (or cables) behind the wall. 1. Install a junction box behind the wall. The EPO box will fasten directly to the junction box. You can use one of the following options: One 4-inch square junction box Two 4-inch square junction boxes One switch box up to 4-gang in size 2. Run the conduit (or cables from the connected devices) to the junction or switch box. The conduit will contain all wiring from the connected devices and all cascading cables. Remove the knockouts required for your installation. When planning your conduit requirements, consider that two cascading cables will fit in.-inch (13-millimeter) conduit and four cascading cables will fit in /-inch (19-millimeter) (conduit. See Cascading multiple EPO boxes on page 8 for more information. 3. Install an appropriate fitting with a lock-nut for each knockout that you are using. 4. Connect your conduit (or cables) to the fitting. 5. Remove one or both of the blanking panels covering the window in the back of the box, as required. 6 EPO System Installation and Operation
10 Installation 6. Secure the EPO box directly to the junction or switch box with the appropriate number of 6-32 screws around the access window. 7. Reinforce the EPO box with 0-inch (6.35- millimeter) screws in the corner mounting holes. (See page 14 for a schematic of the EPO box mounting holes.) The top two 0-inch (6.35- millimeter) mounting holes may be blocked by some junction boxes. In this instance, use only the bottom two 0-inch (6.35-millimeter) mounting holes for reinforcement. EPO System Installation and Operation 7
11 Installation Connect devices to the EPO box Terminals 1 8 are for connecting to APC InfraStruXure devices. Terminal 9 is for connecting to an auxiliary device. Connect only one wire pair (24 18 AWG) to each terminal block. 1. Attach EPO circuits to each InfraStruXure device according to the specific instructions for that device. Use the normally open (NO) contact option. 2. Run suitable wire (24 18 AWG) from the InfraStruXure devices through the conduit to terminals 1 8 on the EPO box terminal block. Make the connections to the terminal block in numerical order (terminal 1, and then terminal 2, etc.). 3. Run suitable wire (22 18 AWG) from the contact closure points for any auxiliary device through the conduit to terminal 9 on the EPO box terminal block. The auxiliary circuit is rated 1A at 48VDC/240VAC. 4. If necessary, secure wires inside the box using the releasable wire ties (provided). Thread the wire ties through the square wire anchors in the box. 5. Connect a suitable ground or PE wire to the #8-32 ground stud in the lower left corner of the EPO box. Mount additional EPO boxes To mount additional EPO boxes at other exit doors, follow the instructions in Mount the system on a wall on page 3. You have two alternatives for wiring your additional EPO boxes. You can cascade the boxes so that you only wire devices to one box (see page 8), or you can wire devices directly to each EPO box (see page 10). 8 EPO System Installation and Operation
12 Installation Cascading multiple EPO boxes When cascading EPO boxes, connect a wire pair from each device to the first EPO box according to the procedure in Connect devices to the EPO box on page 7. Jumper the subsequent EPO boxes with cascading cables (standard Cat-5 cable) this will join the EPO boxes in parallel. InfraStruXure Device InfraStruXure Device InfraStruXure Device Auxiliary Non-InfraStruXure Breaker InfraStruXure Device CAT-5 CAT-5 EPO Box 1 EPO Box 2 EPO Box 3 InfraStruXure Device InfraStruXure Device InfraStruXure Device InfraStruXure Device The recommended maximum total distance of wire you can run per circuit is 1000 feet (300 meters). EPO System Installation and Operation 9
13 Installation Cascade the InfraStruXure devices with Cat-5 cables. Connect the Cat-5 cables to the jacks inside the EPO box. Each cable can support up to four InfraStruXure device wire pairs. Follow these guidelines when connecting Cat-5 cables: Use only the bottom jacks (# and $) if you are cascading four or fewer InfraStruXure devices. Use both the bottom and the top jacks (!, ", #, and $) if you are cascading five or more InfraStruXure devices. Connect the output jacks (! and #) of the first EPO box to the input jacks (" and $) of the second EPO box. Continue until all boxes are connected. If necessary, use the white cable clamps to secure the Cat-5 cables. Box 1 Box 2 Output In put! " # $ Cascade the auxiliary device with wire pairs. After you have ran wires from your auxiliary device (!) to terminal block position 9, run a second set of wires (") from terminal block position 9 on the first EPO box to terminal block position 9 on the second EPO box. Continue until all boxes are connected. (See the diagram on page 8 for reference.) 10 EPO System Installation and Operation
14 Installation Direct wiring alternative If the InfraStruXure devices are centrally located between exit doors, it may be more practical to run separate wire pairs from the devices to each EPO box. This requires terminal block connections in every EPO box, rather than cascading cables between boxes. Connect wire pairs from the Normally Open (NO) contacts on the InfraStruXure devices to each EPO box. Because this alternative results in multiple wire pairs at the terminals of the InfraStruXure devices, it is not recommended for use with more than three EPO boxes. InfraStru Xure Device InfraStru Xure Device InfraStru Xure Device EPO Box 1 Auxiliary Non-InfraStruXure EPO Box 2 Breaker EPO System Installation and Operation 11
15 Verify connections at each EPO box 1. Verify that the wiring is correct before attaching critical load devices to your InfraStruXure devices: a. With the devices powered ON, use a small tool to press each check point, one at a time. Warning Pressing the check point will shut down the connected device and any load it is supporting. If you have an APC FM Series Precision Air Conditioning System connected, pressing the check point will shut off functionality to the unit, but it will still be powered. b. After you have verified the wiring, close the system box, making sure not to pinch wires or disturb connections, and secure with the screws you previously removed. c. As a final test, apply power to all InfraStruXure and auxiliary devices, and then press the EPO button. All connected devices should power OFF immediately. Repeat this final test at every EPO box in your system. See also The InfraStruXure PDUs have an EPO test feature that verifies EPO operation without shutting down the connected loads. Refer to your PDU operation manual for details. 12 EPO System Installation and Operation
16 Operation To engage the system: Lift the shield on any of the boxes that are installed and press the button. When you lift the shield, a red flag drops down from the box to indicate that the shield on the EPO box has been opened, so that if the button is engaged, you will have an easy visual mark as to which EPO box in your room has been activated. To reset the EPO system: Pull the button toward you. Pulling the button does not bring power back to connected equipment; it only resets the EPO system. To close the shield: Push the flag (!) back up into the box and snap the shield tight ("). " To reset your equipment: Apply power to your devices according to the procedures for each device.! EPO System Installation and Operation 13
17 APC InfraStruXure Devices The list below is a selection of compatible APC InfraStruXure devices that you can connect to the EPO system. InfraStruXure for Computer Rooms and Wiring Closets Smart-UPS 3000/5000 RM Symmetra RM UPS InfraStruXure for Medium Data Centers Symmetra PX UPS InfraStruXure PDU InfraStruXure for Large Data Centers Symmetra MW UPS InfraStruXure PDU Precision Air Products NetworkAIR FM The EPO system connects to the InfraStruXure PDU, unless the UPS is sold alone. 14 EPO System Installation and Operation
18 Mounting Hole Template The following illustration shows the location of the mounting holes on the rear of the EPO box. The measurements are in inches (millimeters) (200) 7.64 (194) EPO System Installation and Operation 15
19 1 2 Wiring Diagram SW J9 SW J8 SW J7 SW J6 SW J5 SW J4 SW J3 SW J2 SW J EPO System Installation and Operation
20 Specifications Electrical Input/Output Voltage 24VDC (InfraStruXure circuits) 48VDC/240VAC (External circuit) Current 1A at 24VDC (InfraStruXure circuits) 1A at 48VDC (External circuit) Frequency 50/60Hz Circuits (qty) 9 Contact state Normally open (NO) Physical Dimensions (W L D) EPO box in ( mm) Shipping in ( mm) Weight EPO box 6.4 lb (2.9kg) Shipping 6.9 lb (3.1kg) Mounting Surface mount Connection Removable panels in rear,.-in and /-in knockouts on top and bottom Push button Standard, 22-mm metallic body; 40-mm mushroom head; Push/pull Wire connections #24 to 18 AWG wire ground stud for #8 ring lug Environmental Temperature Humidity Elevation Compliance 23 to 113 F ( 5 to 45 C) 5 to 95% RH, non-condensing 10000ft (3000m) above MSL Standards NFPA 70, NFPA 75, NEC Article 645, 29 CFR , 29 CFR Approvals UL, C-UL, CE EPO System Installation and Operation 17
21 Warranty and Service Limited warranty APC warrants the Emergency Power Off (EPO) System to be free from defects in materials and workmanship for a period of 2 years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser. Warranty limitations Except as provided herein, APC makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. Except as provided above, in no event will APC be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of this product, even if advised of the possibility of such damage. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights, which vary according to jurisdiction. Obtaining service To obtain support for problems with your Emergency Power Off (EPO) System: 0 1. the serial number and date of purchase. 2. Contact Customer Support at the phone number on the back of this document. A technician will try to help you solve the problem by phone. 3. If you must return the product, the technician will give you a return material authorization (RMA) number. If the warranty expired, you will be charged for repair or replacement. 4. Pack the unit carefully. The warranty does not cover damage sustained in transit. Enclose a letter with your name, address, RMA number and daytime phone number; a copy of the sales receipt; and a check as payment, if applicable. 5. Mark the RMA number clearly on the outside of the shipping carton. 6. Ship by insured, prepaid carrier to the address provided by the Customer Support technician. 18 EPO System Installation and Operation
22
23 APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. Global support searching APC Knowledge Base and using e-support. Contact an APC Customer Support center by telephone or . Regional centers: Direct InfraStruXure Customer Support Line (1)(877) (toll free) APC headquarters U.S., Canada Latin America Europe, Middle East, Africa (1)(800) (toll free) (1)(401) (USA) (353)(91) (Ireland) Australia (61) (2) China (86) (10) India (080) Local, country-specific centers: go to for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. Entire contents copyright 2004 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, and InfraStruXure are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only B 08/2004 * B*
Triple Expansion Chassis
Triple Expansion Chassis AP9604 Installation Manual Contents Introduction............................. 1 Installation.............................. 2 Power Considerations...................... 5 Operations..............................
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Installation Guide Smart-UPS X External Battery Pack SMX120BP
Installation Guide Smart-UPS X External Battery Pack SMX120BP Inventory Inspect the contents upon receipt. Notify the carrier and dealer if there is damage. Two bezels Tie brackets used to secure multiple
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V
Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................
Installation. Basic Rack Power Distribution Unit AP9559
Installation Basic Rack Power Distribution Unit AP9559 This manual is available in English on the enclosed CD. Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar. Este manual está disponible
Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V
Installation Smart-UPS VT and MGE Galaxy 3500 Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Contents Safety... 1 SAVE THESE INSTRUCTIONS...............................
APC Step-Down Transformer. User s Manual
APC Step-Down Transformer Models: AP9621, SURT005, SURT006, SUTF3, SYTF2, SYTF2J, SYTF3 and SYTF3J User s Manual English 990-7820D, July 2003 TABLE OF CONTENTS APC Contact Numbers and Support Visit the
User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply
User Manual English APC Smart-UPS SC 1000/1500 VA 110/120/230 Vac 2U Tower/Rack-Mount Uninterruptible Power Supply 990-1851C, 10/2005 Introduction The APC Uninterruptible Power Supply (UPS) is designed
SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE
SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Unpacking, Installation, and Customization
Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................
How To Install A Power Supply (Uplast) With A Battery Pack
APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects
Out-of-Band Management Card
Out-of-Band Management Card AP9608 Installation Manual Related Documents For information on using the Out-of-Band Management Card after installation and startup, see the online User s Guide specific to
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply
User Manual English APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC Tower Uninterruptible Power Supply 990-1587A 12/2005 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a
Operation Manual Smart-UPS C Uninterruptible Power Supply Tower 1000/1500 VA 120/230 Vac su0813a Product Description The APC by Schneider Electric Smart-UPS is a high performance uninterruptible power
Single Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply
User Manual English APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC Tower Uninterruptible Power Supply 990-1074C 06/2012 Introduction American Power Conversion Corporation (APC) is
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
User Manual. English. APC Smart-UPS RT. 3000/5000/6000 VA 200-240 VAC Tower/Rack Mount 3U Uninterruptible Power Supply
User Manual English APC Smart-UPS RT 3000/5000/6000 VA 200-240 VAC Tower/Rack Mount 3U Uninterruptible Power Supply 990-1289D 03/2006 Introduction The APC Smart-UPS RT is a high-performance, uninterruptible
FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual
FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual Asanté Technologies, Inc. 821 Fox Lane San Jose, CA 95131 Copyright Notice Copyright 1997 by Asanté Technologies, Inc. All rights reserved. No
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL CAUTION: This system is not for use with antenna in raised position while
Understanding Emergency Power Off (EPO)
Understanding Emergency Power Off (EPO) White Paper #22 Executive Summary Emergency Power Off (EPO) is the capability to power down a piece of electronic equipment or an entire installation from a single
Back-UPS Pro 1300/1500 Installation and Operation
Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a
User Manual. Smart-UPS TM C. Uninterruptible Power Supply SRC250 SRC450. 110/120/230 Vac. Tower/Rack-Mount 1U
User Manual Smart-UPS TM C Uninterruptible Power Supply SRC250 SRC450 110/120/230 Vac Tower/Rack-Mount 1U Smart-UPS TM C Uninterruptible Power Supply 250/450 VA 110/120/230 Vac Tower/Rack-Mount 1U English
Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA
Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA Important Safety Messages Read the instructions carefully to become familiar with the equipment before trying to install, operate, service
User Manual. English. APC Smart-UPS. 2200 VA 120/230 Vac. 3000 VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply
User Manual English APC Smart-UPS 2200 VA 120/230 Vac 3000 VA 100/120/208/230 Vac 2U Rack Mount Uninterruptible Power Supply 990-1352A 11/2003 Introduction The APC Uninterruptible Power Supply (UPS) is
User Manual. English. APC Smart-UPS RT. 8000/10000 VA 200-240 Vac Tower/Rack-Mount 6U Uninterruptible Power Supply
User Manual English APC Smart-UPS RT 8000/10000 VA 200-240 Vac Tower/Rack-Mount 6U Uninterruptible Power Supply 990-2689D 01/2007 Introduction The APC Smart-UPS RT is a high-performance, uninterruptible
12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
Operation Manual. Smart-UPS UPS. 750/1000/1500/2200 VA Rack-mount 2U 120/230 VAC. 3000 VA Rack-mount 2U 120/208/230 VAC
Operation Manual Smart-UPS UPS 750/1000/1500/2200 VA Rack-mount 2U 120/230 VAC 3000 VA Rack-mount 2U 120/208/230 VAC Contents Overview... 1 Product Description....................................... 1
Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
750VA/1000VA/1500VA 100/120/230VAC 2U
User s Manual English Smart-UPS 750VA/1000VA/1500VA 100/120/230VAC 2U Rack Mount Uninterruptible Power Supply 990-1194 5/02 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent
About Your NetBotz 4-20mA Sensor Pod
Thank you for purchasing this NetBotz 4-20mA Sensor Pod. Each 4-20mA Sensor Pod enables you to connect up to four 4-20mA sensors to your NetBotz 420 or NetBotz 500 appliance. Hundreds of 4-20mA sensors
User Guide. HDMI Active Cable Extender. DVI-7370c
User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0 CONNECTING
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
Installation and Operation Back-UPS 1250, 1300, 1500
Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS
OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS LiteAide HE-100B HE-100BW HE-112 HE-112W HE-117 HE-117W HE-117-2B OWNER'S MANUAL FLOOD LAMPS (BULBS) Your
Machine Safety Switch: SI-LM40 Series Limit Switch Style
Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Installation and Operation
Installation and Operation Smart-UPS ΤΜ SR1 Uninterruptible Power Supply SR18KXIET SR110KXIET 220/230/240 Vac Tower suo0759b Smart-UPS TM SR1 Uninterruptible Power Supply 8000/10000 VA 220/230/240 Vac
Operation Manual. Smart-UPS X Uninterruptible Power Supply
Operation Manual Smart-UPS X Uninterruptible Power Supply Low Voltage (100-127 V) SMX2000RMLV2U SMX2200RMLV2U SMX3000RMLV2U SMX3000RMLV2UNC SMX3000RMJ2U High Voltage (200-240 V) SMX2200RMHV2U SMX3000RMHV2U
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON
FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 (615) 261-2000 Front Matter Abstract This
Back-UPS 650 VA 120 V with AVR (BX650CI-LM)
Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit
DUCT SMOKE DETECTOR D4120
Purpose/Application National and local safety standards and codes recognize the ability of air duct systems to transfer smoke, toxic gases, and flame from area to area. Sometimes smoke can be of such quantity
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
On/Off Relay Switch and 3-Way Switch Kit
45637/45638 Wireless Lighting Control On/Off Relay Switch and 3-Way Switch Kit marthome Control the On/Off status of permanently installed lighting, fans and more! www.lowes.com/iris 2012 JASCO Made in
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
Solid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : [email protected] Solid-State Timer Low-Cost, Plug-In
Dolphin 9900 Mobile Computers
Dolphin 9900 Mobile Computers Dolphin 9900 Dolphin 9950 Dolphin 9951 with Windows Mobile 6.1 Quick Start Guide Dolphin 9900 Series Quick Start Guide Out of the Box Verify that the box contains the following
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
Remote Alarm Monitoring System
Remote Alarm Monitoring System Operation and Service Manual Model RA1 RA4 A A Version HELMER SCIENTIFIC 14400 Bergen Boulevard Noblesville, IN 46060 USA PH +1.317.773.9073 FAX +1.317.773.9082 USA and Canada
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
Installation and Operation Guide PD4600 Series Converter Replacement
Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your
PEDAL POWER. User s Manual
PEDAL POWER AC User s Manual Copyright 2005-2008 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by
Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES
Installation Instructions Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES Read This Book This book has important information
Architect/Contractor Information Package
Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.
Product Description The APC by Schneider Electric Smart-UPS is a high performance uninterruptible power supply (UPS). The UPS provides protection for electronic equipment from utility power blackouts,
Installation and Operation Guide for PD4000 Series Power Control Center
Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your
PS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
Bubble King. User Manual
Bubble King User Manual TABLE OF CONTENTS 1. Before You Begin... 3 What Is Included... 3 Unpacking Instructions... 3 Claims... 3 Text Conventions... 3 Icons... 3 Document Information... 3 Product at a
AGS. Owner's Manual. Xantrex Automatic Generator Start Control System
AGS Owner's Manual Xantrex Automatic Generator Start Control System TABLE OF CONTENTS INTRODUCTION...3 Main Features...3 Safety Summary...3 THINGS YOU SHOULD KNOW...4 THEORY OF OPERATION...5 System...5
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger
Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
Model PS-4001 Power Supply User Instructions
Model PS-4001 Power Supply User Instructions 9350-7710-000 Rev E 9/2009 PROPRIETARY NOTICE The product information and design disclosed herein were originated by and are the property of Bosch Security
APC Smart-UPS 2400/3000 VA 100/110-120 VAC 3U. Uninterruptible Power Supply
User Manual English APC Smart-UPS 2400/3000 VA 100/110-120 VAC 3U Tower/Rack Mount Uninterruptible Power Supply 990-2233A 02/2005 Introduction/Before Installation Introduction/Before Installation About
Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1
REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com
TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER
TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This
Installation and Operation Guide for PD4100 Series Power Control Centers
Installation and Operation Guide for PD4100 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as
V-2901 UNIVERSAL DOOR ANSWERING SYSTEM
VSP-V-2901 Issue 6 V-2901 UNIVERSAL DOOR ANSWERING SYSTEM INTRODUCTI The V-2901 is a Universal Door Answering System for use with any single line telephone, electronic or 1A2 key system, or PABX. These
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
OAK WORKBENCH WITH 2 DRAWERS
OAK WORKBENCH WITH 2 DRAWERS Model 93991 ASSEMBLY Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury.
Electric Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
Crestron TMK-6L & WMKT-6L Trim Ring Mount Kits Installation Guide
Crestron TMK-6L & WMKT-6L Trim Ring Mount Kits Installation Guide This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh,
Canopy Surge. User Manual
Canopy Surge Suppressor User Manual SS00-UM-en Issue 2 May 2003 2003 Motorola, Inc. All rights reserved. Printed in the U.S.A Notices Safety Precautions: Before beginning your installation, please read
Leak Detection System
Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input
PagePac PAGEPAL V-5335700
PagePac Issue 3 by PAGEPAL V-5335700 INTRODUCTION The PagePal unit interfaces most telephone systems (PBX, KTS, Centrex) to virtually any public address audio system. In addition, PagePal furnishes inputs
Battery Charger. Instruction Manual 309502G
Instruction Manual Battery Charger 309502G EN Part No. 117427, Single Bay Charger, Series B, North America (N.A.) Part No. 120110, Single Bay Charger, Series B, Australia Part No. 117429, Four Bay Charger,
Power Management Module 2. Installation
Power Management Module 2 30 300 kva Installation Table of Contents Safety... 1 Safety Instructions... 1 Certification Standards Three Phase... 1 Product Safety... 2 Special Precautions... 2 System Description...