Z-Drive 6000 PCIe NVMe SSD Series Dual Port Capability

Size: px
Start display at page:

Download "Z-Drive 6000 PCIe NVMe SSD Series Dual Port Capability"

Transcription

1 Z-Drive 6000 PCIe NVMe SSD Series Dual Port Capability Maulik Sompura George Tehrani Scott Harlin Published September 2015 OCZ Storage Solutions, Inc. A Toshiba Group Company

2 Table of Contents Page Executive Summary Background Purpose and Applications Single Port vs Dual Port Applications & Differences 4.1 Dual Port Applications 4.2 Single Port Applications Identifying & Isolating Single Points of Failure Dual Port Functionality in PCIe SSDs Enabling Dual Port on Z-Drive 6000 SSDs Dual Port Performance & Verification Z-Drive 6000 Series Configurations 9.1 Customer Impact 9.2 Use Cases Summary Disclaimer OCZ may make changes to specifications and product descriptions at any time, without notice. The information presented in this document is for informational purposes only and may contain technical inaccuracies, omissions and typographical errors. Any performance tests and ratings are measured using systems that reflect the approximate performance of OCZ products as measured by those tests. Any differences in software or hardware configuration may affect actual performance, and OCZ does not control the design or implementation of third party benchmarks or websites referenced in this document. The information contained herein is subject to change and may be rendered inaccurate for many reasons, including but not limited to any changes in product and/or roadmap, component and hardware revision changes, new model and/or product releases, software changes, firmware changes, or the like. OCZ assumes no obligation to update or otherwise correct or revise this information. OCZ MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE CONTENTS HEREOF AND ASSUMES NO RESPONSIBILITY FOR ANY INACCURACIES, ERRORS OR OMISSIONS THAT MAY APPEAR IN THIS INFORMATION. OCZ SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. IN NO EVENT WILL OCZ BE LIABLE TO ANY PERSON FOR ANY DIRECT, INDIRECT, SPECIAL OR OTHER CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF ANY INFORMATION CONTAINED HEREIN, EVEN IF OCZ IS EXPRESSLY ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. ATTRIBUTION 2015 OCZ Storage Solutions, Inc. A Toshiba Group Company. All rights reserved. OCZ, the OCZ logo, OCZ XXXX, OCZ XXXXX, [Product name] and combinations thereof, are trademarks of OCZ Storage Solutions, Inc. A Toshiba Group Company. All other products names and logos are for reference only and may be trademarks of their respective owners. 2

3 1 Executive Summary This paper focuses on the dual port aspects of a PCIe SSD. It provides a high-level description on dual port versus single port use cases and applications. It is further intended to help system architects and designers to address dual port functionality especially since this capability is now supported on new PCIe-based NVMe (Non-Volatile Memory express) platforms. Dual port is one of those capabilities that server and storage OEMs place high on their priority lists because it enables High Availability (HA) for enterprise applications, redundancy, and sustained uptime reliability. The dual port implementation within OCZ Storage Solutions NVMe-compliant Z-Drive 6000 SSD Series is also included in this paper. 2 Background Dual data-paths (or multi-paths) are not new to enterprise applications. Originally, computers were connected to a device using a single data-path, and as this progressed over time, the enterprise community learned that high rates of failures were typically generated from backplanes, host bus adapters, cabling, connectors, etc., primarily due to moving parts and mechanical connections. As a result, redundancy soon became available in terms of RAID for disk drives, data duplication, and other techniques. In the single-path scenario, if the data path from the host to the drive itself is compromised, data cannot be accessed paving the way for the dual-path (or multi-path) concept. Focusing on this multi-path technique from the drive to the host and vice-versa, SCSI devices were the first to implement dual port capabilities using two physical connections. With the advent of Serial Attached SCSI (SAS), dual port connectivity became possible through a single physical connection. Due to its benefits, SAS dual port quickly became a popular configuration. As dual port enables data to be streamed from either port independently, the technique provides fault tolerance for either one of the data paths. This same dual port functionality can now be achieved on PCIe NVMe SSDs. Dual port enables two data paths within a single host so that two controllers can access the same storage device for redundancy. In another usage, two host systems could also concurrently access the same drive with dual port. If a system failure or power loss occurs where one data path is lost, the available data path continues operation as if no failure had occurred with minimal impact to Quality of Service (QoS). 3

4 3 Purpose and Applications Enterprise customers rely on data redundancy or data replication that is achieved via two different availability approaches: 1. Approach #1 - High Availability: This implementation is highly reliable and typically avoids single point failures. One of the ways that high data availability is ensured is through two identical data paths. Applications that require this level of HA in support of mission-critical data include banking & financial, OnLine Transaction Processing (OLTP), OnLine Analytical Processing (OLAP), virtualization, High Performance Computing (HPC), and Big Data. For this class of applications, redundancy is architected at every point in the data path to avoid failures. A popular implementation is described in Sections 4 and Approach #2 - Moderate to High Availability: This implementation provides moderate data availability due to cost-constraints of implementing multi-point redundancy. Examples in this case include hyperscale and cloud service providers that add redundancy through clustering and redundant copies of data at different locations so that in the case of a failure, instead of using sophisticated dual-domain/dual-path redundancy, new cost-efficient drives are rebuilt using backed-up data from an alternate location replacing the failed drives. However, this approach does not mean that this is a cheaper solution. In fact, Total Cost of Ownership (TCO) might be higher in some cases if multiple copies of data need to be maintained requiring additional drives and software costs. System architects need to consider the full TCO benefit, as well as the pros and cons of the two approaches. 4 Single Port vs. Dual Port Applications & Differences 4.1 Dual Port Applications The most popular use case for dual port is when two controllers concurrently access the same device, such as an SSD, to allow for data redundancy. In this configuration, the two flash controllers can access the same data within a device through different ports as evident in the popular JBOD/JBOF (Just a Bunch of Disks/ Just a Bunch of Flash) configuration in Figure 1. Virtualized environments also need this level of HA to protect mission-critical data from system failures. For these applications, redundancy is built-in at every point in the data path to avoid failures associated with devices, components, cables, etc. 4

5 JBOF High Availability Data or Metadata Multi-ported Device Redundancy based on Usage Controller A Root Complex PCIe Switch Controller B Root Complex PCIe Switch NVMe NVMe NVMe NVMe Figure 1 is an example of a JBOF High Availability configuration 4.2 Single Port Applications There are single port use cases where data redundancy is not required. This is evident in server caching applications where caching is used for temporary data storage or as a scratch pad. The same is true in power-critical client storage applications where data is non-redundant and the objective is to reduce the power consumption while adding a fast PCIe NVMe SSD to supplement or replace a slower form of storage. Both the server caching and client storage configurations are represented in Figure 2. Server Caching Root NVMe Complex Temporary data Non-redundant PCIe Switch Reduced memory footprint NVMe NVMe NVMe Client Storage Boot/OS drive or HDD cache Non-redundant Power optimized NVMe Root Complex PCI Controller Hub (PCH) SATA HDD Figure 2 represents two single port use cases that do not require data redundancy 5

6 5 Identifying & Isolating Single Points of Failure In this section, single points of failure are described below. As represented in Figure 3, there is typically one server/controller (Server 1) that utilizes a host bus adapter (HBA 1) to connect to the SSDs via a PCIe switch (SW1). If this connection fails, access to data would be lost. To support failover in this configuration, an extra HBA can be added to the server (as depicted by HBA 2). Though failover is supported in this configuration, there is only one switch connecting to the drives, so if the switch fails, access to data would still be lost. Server 1 SSD HBA 1 HBA 2 SW 1 SSD SSD Figure 3 is a configuration that addresses single point failures SSD To avoid these single points of failure, utilizing dual port drives and two switches that connect to every drive will alleviate this problem. However, if the server is lost (Server 1), access to data will still be lost. Therefore, depending on associated costs, the addition of a second server could achieve a fully redundant system where both servers could access all of the dual ported drives via two switches as outlined in Figure 4. In this configuration, the dual ports are active/active enabling both controllers to access any drive port at any time representing a fully redundant, dual ported configuration. Server 1 HBA 1 HBA 2 SW 1 DP SSD DP SSD Server 2 HBA 1 HBA 2 SW 2 DP SSD DP SSD Figure 4 represents a dual-ported configuration 6

7 Connector Connector 6 Dual Port Functionality In PCIe SSDs The Enterprise SSD Form Factor Working Group defined its latest SFF-8639 connector (or U.2 form factor), and as part of its definition, includes dual port enablement. The mechanism for enabling dual port operation is DualPortEn# (pin E25) as depicted in Figure 5. Enterprise PCIe (SFF-8639) Pin Name E22 GND E23 SMClk E24 SMDat E25 DualPortEn# Source: Enterprise SSD Form Factor Working Group. Figure 5: Depicts pin E25 as the mechanism for enabling dual port operations The enablement is defined so that an enterprise PCIe SSD can be configured as either a single x4 controller or as dual x2 controllers as outlined in Figure 6. Typical Server Configuration PCIe upstream (e.g. CPU x 4 PCIe port) PCIe x 4 SSD Form Factor Device (Enterprise PCIe SSD) Cmd Q Data Typical Server Configuration Controller A Controller B PCIe x 2 PCIe x 2 SSD Form Factor Device (Enterprise PCIe SSD) Cmd Q Data Cmd Q Data Figure 6 defines a PCIe SSD configuration with either a single x4 controller or with dual x2 controllers It is typically pulled high internal to the enterprise PCIe SSD which means that if nothing is connected to the pin (pin E25), the state of the pin will be high and the dual port capability will not be enabled If DualPortEn# (pin E25) is left open, the PCIe interface will be configured as a single x4 port If DualPortEn is pulled low by the system (driven low or grounded by a backplane), the dual port capability will be enabled and explained further in the next section 7

8 7 Enabling Dual Port On Z-Drive 6000 SSDs OCZ s launch strategy for the Z-Drive 6000 Series is to release a single port version first followed by a dual-port version. The Z-Drive 6000 hardware supports dual port as explained in the previous section. To upgrade from single port to dual port, all that is required is a firmware update. Customers need to contact OCZ sales or product management to make sure of the correct firmware version for dual port enablement. Once confirmed, the Z Drive 6000 Series supports dual x2 PCIe Gen3 or single x4 PCIe Gen3 depending on the DualPortEn# SFF8639 pin setting. In either case, four namespaces are available (two for each server) where each host can access either namespace. If the namespaces are shared and a collision may be possible, hosts rely on reservation/ release NVMe commands. Figure 7 depicts this dual port and namespace implementation. NVM Subsystem PCIe Port Host Interface 0 Host Interface 1 Host PCIe Link NVMe Controller (Instance of CSRs) I/O Requests Admin Commands I/O Requests Admin Commands Host PCIe Link Defined by the NVMe Spec. PCIe Port NVMe Controller (Instance of CSRs) Namespace Host 0 PCIe Connection Synchronization Reservations (Access Exclusion/Synchronization) Host 0 PCIe Connection Non-Volatile Storage (Flash) Namespace 0 Namespace 1 Figure 7 depicts NVMe namespace management and the dual port implementation Dual port functionality is enabled automatically on Z-Drive 6000 SSDs with the dual port enabling firmware. If pin E25 (DualPortEn#) is pulled low by the system (driven low or grounded by a backplane), the dual port capability will be enabled. The Z-Drive 6000 Series is dependent on the host system to enable dual port functionality as described. 8

9 8 Dual Port Performance & Verification As mentioned earlier, a Z-Drive 6000 SSD can operate in dual x2 PCIe Gen3 or a single x4 PCIe Gen3. Hence, dual port functionality will split bandwidth and/or IOPS performance in half on each port. Therefore, given one Z-Drive 6000 SSD (either 1.6TB or 3.2TB), the 4KB random read performance of ~700,000 IOPS on a single x4 port would deliver ~350,000 IOPS split on each x2 port. It is extremely important to test the dual port capability of SSDs correctly. The first step is to determine if both ports are functioning properly and delivering nearly half of the bandwidth of what single port would deliver. Secondly, if a fault is injected into one of the data paths or when one of the ports is down, verification needs to determine if the data can be accessed through the other port. As it relates to power cycle testing, verifications will also need to determine if both ports boot up perfectly every time. Are there evident performance degradations? Therefore, it is important to verify different temperature conditions, workloads, fault injections into ports, power cycling, etc. to provide the full confidence that in an enterprise server, the SSD will function as specified. The Z-Drive 6000 SSD Series is fully tested and verified to perform dual port functionality as specified. 9 Z-Drive 6000 Series Configurations 9.1 Customer Impact NVMe is a standard that meets the needs of enterprise-class storage requirements. Since PCIe does not define registers, direct memory access, command sets or feature-sets for storage devices, NVMe fills the gap nicely as a standard software interface, and also replaces proprietary software interfaces and drivers previously used by PCIe-based SSDs. For the enterprise, the Z-Drive 6000 Series offers very low latency, high performance, and selectable power envelopes. In particular, storage latency has become fundamentally important for new applications especially in support of virtual infrastructure and Big Data applications (including business intelligence and data analytics). Getting the most performance and efficiency out of an enterprise SSD to support the real-time I/O needs of these applications is critical, and bypassing the traditional ATA and SCSI stack greatly shortens the path for an I/O request. The Z-Drive 6000 Series represents a complete dual ported solid-state storage solution that has the potential to save enterprise customers many hundreds of thousands of dollars because it minimizes storage overprovisioning as well as the associated overhead. By deploying high-performance Z-Drive 6000 SSDs in server enclosures that natively support the NVMe U.2 interface enable companies to cost-effectively use hyper-converged systems and hybrid cloud-based applications that enable scalability without having to build out expensive storage infrastructures. 9

10 9.2 Use Cases This section describes use cases for integrating Z-Drive 6000 Series SSDs into an IT environment and ideal for OLTP and OnLine Analytical Processing (OLAP) applications. As OLTP applications handle many short transactions in quick, random bursts, the Z-Drive 6000 Series is well-suited to accelerate the processing of these transactions for a variety of business needs that include: Analytics Content Delivery (streaming media, video on demand) Critical infrastructure applications (Supervisory Control And Data Acquisition/SCADA) Database Query Acceleration Financial and Ledgers Gaming Video Surveillance Real-time Billing Real-time Monitoring Trading As OLAP applications handle bigger chunks of data, the data must be retrieved from multiple sources and respond quickly to complex queries. OLAP applications can also be used for a similarly diverse set of business workloads that include: Business Intelligence Batch Processing Data Warehousing and Report Generation ERP Systems High Transaction Processing (HTP) Massive Data Feeds and Reporting As described previously, a bulk of these applications that require high bandwidth and low latency performance also need redundancy and high availability of the data. As SSDs provide such advantages as dual port functionality and redundant paths to the data, business-critical applications will not suffer as the Z-Drive 6000 Series is an excellent fit for the applications listed above. 10

11 10 Summary The SSD industry is in its nascent stage with regard to NVMe PCIe platforms and drives and as such, servers with dual port capabilities are still not in production. As the industry transitions into a newer, faster era of NVMe PCIe drives in 2016 and beyond, more drives and platforms will implement dual port capabilities and will provide enterprise customers and their applications with the benefits of this functionality. As scalability and HA are fundamental requirements for any server or storage OEM s networked storage solution, the PCIe 3.0 interface can attach a large number of high density SSDs to deliver petabyte scalability needed for Big Data applications. The Z-Drive 6000 Series scalability is only limited by the number of U.2 drive bays. To achieve HA, the Z-Drive 6000 Series implements dual port capabilities that enable redundant data access that eliminate a single point of failure. With the advent of NVMe PCIe SSDs, more customers will leverage this key feature and some may even replace SAS-based SSDs with dual port capable PCIe NVMe drives due to their very high throughput, low latencies, and other performance and feature-related advantages. Depending on the application, moderate to high availability of the data requirement and infrastructure budgets, enterprise customers will soon have the option to deploy dual port versus single port solid-state storage devices. OCZ is a pioneer in this technology and was the first to showcase dual port functionality with the Z-Drive 6000 Series in an all-nvme members conference held in April Dual port functionality is scheduled for availability within the Z-Drive 6000 / 6300 Series in October

Answering the Requirements of Flash-Based SSDs in the Virtualized Data Center

Answering the Requirements of Flash-Based SSDs in the Virtualized Data Center White Paper Answering the Requirements of Flash-Based SSDs in the Virtualized Data Center Provide accelerated data access and an immediate performance boost of businesscritical applications with caching

More information

Accelerating Database Applications on Linux Servers

Accelerating Database Applications on Linux Servers White Paper Accelerating Database Applications on Linux Servers Introducing OCZ s LXL Software - Delivering a Data-Path Optimized Solution for Flash Acceleration Allon Cohen, PhD Yaron Klein Eli Ben Namer

More information

MS Exchange Server Acceleration

MS Exchange Server Acceleration White Paper MS Exchange Server Acceleration Using virtualization to dramatically maximize user experience for Microsoft Exchange Server Allon Cohen, PhD Scott Harlin OCZ Storage Solutions, Inc. A Toshiba

More information

Cartal-Rijsbergen Automotive Improves SQL Server Performance and I/O Database Access with OCZ s PCIe-based ZD-XL SQL Accelerator

Cartal-Rijsbergen Automotive Improves SQL Server Performance and I/O Database Access with OCZ s PCIe-based ZD-XL SQL Accelerator enterprise Case Study Cartal-Rijsbergen Automotive Improves SQL Server Performance and I/O Database Access with OCZ s PCIe-based ZD-XL SQL Accelerator ZD-XL SQL Accelerator Significantly Boosts Data Warehousing,

More information

Optimizing SQL Server AlwaysOn Implementations with OCZ s ZD-XL SQL Accelerator

Optimizing SQL Server AlwaysOn Implementations with OCZ s ZD-XL SQL Accelerator White Paper Optimizing SQL Server AlwaysOn Implementations with OCZ s ZD-XL SQL Accelerator Delivering Accelerated Application Performance, Microsoft AlwaysOn High Availability and Fast Data Replication

More information

Supreme Court of Italy Improves Oracle Database Performance and I/O Access to Court Proceedings with OCZ s PCIe-based Virtualized Solution

Supreme Court of Italy Improves Oracle Database Performance and I/O Access to Court Proceedings with OCZ s PCIe-based Virtualized Solution enterprise Case Study Supreme Court of Italy Improves Oracle Database Performance and I/O Access to Court Proceedings with OCZ s PCIe-based Virtualized Solution Combination of Z-Drive R4 PCIe SSDs and

More information

Delivering Accelerated SQL Server Performance with OCZ s ZD-XL SQL Accelerator

Delivering Accelerated SQL Server Performance with OCZ s ZD-XL SQL Accelerator enterprise White Paper Delivering Accelerated SQL Server Performance with OCZ s ZD-XL SQL Accelerator Performance Test Results for Analytical (OLAP) and Transactional (OLTP) SQL Server 212 Loads Allon

More information

Driving Big Data with OCZ Enterprise SSDs

Driving Big Data with OCZ Enterprise SSDs White Paper Driving Big Data with OCZ Enterprise SSDs Part 2: Delivering the Performance and Management Required for Big Data Applications Scott Harlin Published June 2014 OCZ Storage Solutions, Inc. A

More information

Transforming Data Center Economics and Performance via Flash and Server Virtualization

Transforming Data Center Economics and Performance via Flash and Server Virtualization White Paper Transforming Data Center Economics and Performance via Flash and Server Virtualization How OCZ PCIe Flash-Based SSDs and VXL Software Create a Lean, Mean & Green Data Center Allon Cohen, PhD

More information

Accelerating MS SQL Server 2012

Accelerating MS SQL Server 2012 White Paper Accelerating MS SQL Server 2012 Unleashing the Full Power of SQL Server 2012 in Virtualized Data Centers Allon Cohen, PhD Scott Harlin OCZ Storage Solutions, Inc. A Toshiba Group Company 1

More information

OCZ s NVMe SSDs provide Lower Latency and Faster, more Consistent Performance

OCZ s NVMe SSDs provide Lower Latency and Faster, more Consistent Performance OCZ s NVMe SSDs provide Lower Latency and Faster, more Consistent Performance by George Crump, Lead Analyst! When non-volatile flash memory-based solid-state drives (SSDs) were introduced, the protocol

More information

Intel RAID SSD Cache Controller RCS25ZB040

Intel RAID SSD Cache Controller RCS25ZB040 SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash Intel RAID SSD Cache Controller RCS25ZB040 When Faster

More information

NVM Express TM Infrastructure - Exploring Data Center PCIe Topologies

NVM Express TM Infrastructure - Exploring Data Center PCIe Topologies Architected for Performance NVM Express TM Infrastructure - Exploring Data Center PCIe Topologies January 29, 2015 Jonmichael Hands Product Marketing Manager, Intel Non-Volatile Memory Solutions Group

More information

EMC XtremSF: Delivering Next Generation Performance for Oracle Database

EMC XtremSF: Delivering Next Generation Performance for Oracle Database White Paper EMC XtremSF: Delivering Next Generation Performance for Oracle Database Abstract This white paper addresses the challenges currently facing business executives to store and process the growing

More information

EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server

EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server White Paper EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server Abstract This white paper addresses the challenges currently facing business executives to store and process the growing

More information

Redundancy in enterprise storage networks using dual-domain SAS configurations

Redundancy in enterprise storage networks using dual-domain SAS configurations Redundancy in enterprise storage networks using dual-domain SAS configurations technology brief Abstract... 2 Introduction... 2 Why dual-domain SAS is important... 2 Single SAS domain... 3 Dual-domain

More information

The Next Frontier of Data Center Virtualization - Flash in the Era of Distributed Storage

The Next Frontier of Data Center Virtualization - Flash in the Era of Distributed Storage White Paper The Next Frontier of Data Center Virtualization - Flash in the Era of Distributed Storage A Deeper Dive into the Capabilities of OCZ s VXL 1.2 Software Delivering the Next Revolution of Storage

More information

Transitioning to 6Gb/s SAS (Serial-Attached SCSI) A Dell White Paper

Transitioning to 6Gb/s SAS (Serial-Attached SCSI) A Dell White Paper Transitioning to 6Gb/s SAS (Serial-Attached SCSI) A Dell White Paper December 2009 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES.

More information

Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array

Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array Evaluation report prepared under contract with Lenovo Executive Summary Even with the price of flash

More information

Accelerating Server Storage Performance on Lenovo ThinkServer

Accelerating Server Storage Performance on Lenovo ThinkServer Accelerating Server Storage Performance on Lenovo ThinkServer Lenovo Enterprise Product Group April 214 Copyright Lenovo 214 LENOVO PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER

More information

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION A DIABLO WHITE PAPER AUGUST 2014 Ricky Trigalo Director of Business Development Virtualization, Diablo Technologies

More information

Converged storage architecture for Oracle RAC based on NVMe SSDs and standard x86 servers

Converged storage architecture for Oracle RAC based on NVMe SSDs and standard x86 servers Converged storage architecture for Oracle RAC based on NVMe SSDs and standard x86 servers White Paper rev. 2015-11-27 2015 FlashGrid Inc. 1 www.flashgrid.io Abstract Oracle Real Application Clusters (RAC)

More information

Running Oracle s PeopleSoft Human Capital Management on Oracle SuperCluster T5-8 O R A C L E W H I T E P A P E R L A S T U P D A T E D J U N E 2 0 15

Running Oracle s PeopleSoft Human Capital Management on Oracle SuperCluster T5-8 O R A C L E W H I T E P A P E R L A S T U P D A T E D J U N E 2 0 15 Running Oracle s PeopleSoft Human Capital Management on Oracle SuperCluster T5-8 O R A C L E W H I T E P A P E R L A S T U P D A T E D J U N E 2 0 15 Table of Contents Fully Integrated Hardware and Software

More information

Scaling from Datacenter to Client

Scaling from Datacenter to Client Scaling from Datacenter to Client KeunSoo Jo Sr. Manager Memory Product Planning Samsung Semiconductor Audio-Visual Sponsor Outline SSD Market Overview & Trends - Enterprise What brought us to NVMe Technology

More information

A Vision for Tomorrow s Hosting Data Center

A Vision for Tomorrow s Hosting Data Center A Vision for Tomorrow s Hosting Data Center JOHN WILLIAMS CORPORATE VICE PRESIDENT, SERVER MARKETING MARCH 2013 THE EVOLVING HOSTING MARKET NEW OPPORTUNITIES: HOSTING IN THE CLOUD Hosted Server shipments

More information

EMC VFCACHE ACCELERATES ORACLE

EMC VFCACHE ACCELERATES ORACLE White Paper EMC VFCACHE ACCELERATES ORACLE VFCache extends Flash to the server FAST Suite automates storage placement in the array VNX protects data EMC Solutions Group Abstract This white paper describes

More information

PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering

PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express 2.0 SATA Controller Card enables 4 AHCI SATA III

More information

Server-Side Virtual Controller Technology (SVCT)

Server-Side Virtual Controller Technology (SVCT) TECHNOLOGY BRIEF Server-Side Virtual Controller Technology (SVCT) All traditional storage suffers from the I/O blender that severely impacts application performance, because traditional storage is still

More information

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820 Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820 This white paper discusses the SQL server workload consolidation capabilities of Dell PowerEdge R820 using Virtualization.

More information

Post-production Video Editing Solution Guide with Quantum StorNext File System AssuredSAN 4000

Post-production Video Editing Solution Guide with Quantum StorNext File System AssuredSAN 4000 Post-production Video Editing Solution Guide with Quantum StorNext File System AssuredSAN 4000 Dot Hill Systems introduction 1 INTRODUCTION Dot Hill Systems offers high performance network storage products

More information

Redefining Flash Storage Solution

Redefining Flash Storage Solution Redefining Flash Storage Solution Through Capacity + Efficiency + Performance + Form PRODUCT GUIDE Holistic Approach to Redefine Flash Storage Novachips is a leading provider of a broad range of Flash

More information

The functionality and advantages of a high-availability file server system

The functionality and advantages of a high-availability file server system The functionality and advantages of a high-availability file server system This paper discusses the benefits of deploying a JMR SHARE High-Availability File Server System. Hardware and performance considerations

More information

The 8Gb Fibre Channel Adapter of Choice in Oracle Environments

The 8Gb Fibre Channel Adapter of Choice in Oracle Environments White Paper The 8Gb Fibre Channel Adapter of Choice in Oracle Environments QLogic s 8Gb Adapters Outperform in Oracle Environments Key Findings For demanding enterprise database applications such as Oracle,

More information

Benefits of Solid-State Storage

Benefits of Solid-State Storage This Dell technical white paper describes the different types of solid-state storage and the benefits of each. Jeff Armstrong Gary Kotzur Rahul Deshmukh Contents Introduction... 3 PCIe-SSS... 3 Differences

More information

StorageBox 1000. High Performance NVMe JBOF

StorageBox 1000. High Performance NVMe JBOF High Performance NVMe JBOF The High Capacity, Fastest and Most Modular Direct Attached NVMe Storage Device for VDI and HPC BLAZING 12GB/s SPEED 8 DRIVES [1U ] WORKS WITH ANY SERVER The Magma StorageBox

More information

Serial ATA technology

Serial ATA technology Serial ATA technology Technology brief, 4 th edition Introduction... 2 SATA devices and interoperability with SAS devices... 2 Initiators... 2 Expanders... 3 Targets and their recommended uses... 3 Entry

More information

Hardware RAID vs. Software RAID: Which Implementation is Best for my Application?

Hardware RAID vs. Software RAID: Which Implementation is Best for my Application? STORAGE SOLUTIONS WHITE PAPER Hardware vs. Software : Which Implementation is Best for my Application? Contents Introduction...1 What is?...1 Software...1 Software Implementations...1 Hardware...2 Hardware

More information

Intel RAID Performance 12Gb/s SAS RAID Controllers

Intel RAID Performance 12Gb/s SAS RAID Controllers Intel RAID Performance 12Gb/s SAS RAID Controllers WHITE PAPER September 2014 DB10-000023-00 For more information on the Intel RAID visit: www.intel.com/go/raid Intel, the Intel logo, Intel Inside, Xeon

More information

IBM System Storage DS5020 Express

IBM System Storage DS5020 Express IBM DS5020 Express Manage growth, complexity, and risk with scalable, high-performance storage Highlights Mixed host interfaces support (Fibre Channel/iSCSI) enables SAN tiering Balanced performance well-suited

More information

Direct Scale-out Flash Storage: Data Path Evolution for the Flash Storage Era

Direct Scale-out Flash Storage: Data Path Evolution for the Flash Storage Era Enterprise Strategy Group Getting to the bigger truth. White Paper Direct Scale-out Flash Storage: Data Path Evolution for the Flash Storage Era Apeiron introduces NVMe-based storage innovation designed

More information

All-Flash Storage Solution for SAP HANA:

All-Flash Storage Solution for SAP HANA: All-Flash Storage Solution for SAP HANA: Storage Considerations using SanDisk Solid State Devices WHITE PAPER 951 SanDisk Drive, Milpitas, CA 95035 www.sandisk.com Table of Contents Preface 3 Why SanDisk?

More information

How To Scale Myroster With Flash Memory From Hgst On A Flash Flash Flash Memory On A Slave Server

How To Scale Myroster With Flash Memory From Hgst On A Flash Flash Flash Memory On A Slave Server White Paper October 2014 Scaling MySQL Deployments Using HGST FlashMAX PCIe SSDs An HGST and Percona Collaborative Whitepaper Table of Contents Introduction The Challenge Read Workload Scaling...1 Write

More information

How A V3 Appliance Employs Superior VDI Architecture to Reduce Latency and Increase Performance

How A V3 Appliance Employs Superior VDI Architecture to Reduce Latency and Increase Performance How A V3 Appliance Employs Superior VDI Architecture to Reduce Latency and Increase Performance www. ipro-com.com/i t Contents Overview...3 Introduction...3 Understanding Latency...3 Network Latency...3

More information

HadoopTM Analytics DDN

HadoopTM Analytics DDN DDN Solution Brief Accelerate> HadoopTM Analytics with the SFA Big Data Platform Organizations that need to extract value from all data can leverage the award winning SFA platform to really accelerate

More information

Data Center Storage Solutions

Data Center Storage Solutions Data Center Storage Solutions Enterprise software, appliance and hardware solutions you can trust When it comes to storage, most enterprises seek the same things: predictable performance, trusted reliability

More information

INCREASING EFFICIENCY WITH EASY AND COMPREHENSIVE STORAGE MANAGEMENT

INCREASING EFFICIENCY WITH EASY AND COMPREHENSIVE STORAGE MANAGEMENT INCREASING EFFICIENCY WITH EASY AND COMPREHENSIVE STORAGE MANAGEMENT UNPRECEDENTED OBSERVABILITY, COST-SAVING PERFORMANCE ACCELERATION, AND SUPERIOR DATA PROTECTION KEY FEATURES Unprecedented observability

More information

ANY SURVEILLANCE, ANYWHERE, ANYTIME

ANY SURVEILLANCE, ANYWHERE, ANYTIME ANY SURVEILLANCE, ANYWHERE, ANYTIME WHITEPAPER DDN Storage Powers Next Generation Video Surveillance Infrastructure INTRODUCTION Over the past decade, the world has seen tremendous growth in the use of

More information

The Shortcut Guide to Balancing Storage Costs and Performance with Hybrid Storage

The Shortcut Guide to Balancing Storage Costs and Performance with Hybrid Storage The Shortcut Guide to Balancing Storage Costs and Performance with Hybrid Storage sponsored by Dan Sullivan Chapter 1: Advantages of Hybrid Storage... 1 Overview of Flash Deployment in Hybrid Storage Systems...

More information

Accelerating Enterprise Applications and Reducing TCO with SanDisk ZetaScale Software

Accelerating Enterprise Applications and Reducing TCO with SanDisk ZetaScale Software WHITEPAPER Accelerating Enterprise Applications and Reducing TCO with SanDisk ZetaScale Software SanDisk ZetaScale software unlocks the full benefits of flash for In-Memory Compute and NoSQL applications

More information

A Close Look at PCI Express SSDs. Shirish Jamthe Director of System Engineering Virident Systems, Inc. August 2011

A Close Look at PCI Express SSDs. Shirish Jamthe Director of System Engineering Virident Systems, Inc. August 2011 A Close Look at PCI Express SSDs Shirish Jamthe Director of System Engineering Virident Systems, Inc. August 2011 Macro Datacenter Trends Key driver: Information Processing Data Footprint (PB) CAGR: 100%

More information

The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment

The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment Introduction... 2 Virtualization addresses key challenges facing IT today... 2 Introducing Virtuozzo... 2 A virtualized environment

More information

Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments

Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments Applied Technology Abstract This white paper introduces EMC s latest groundbreaking technologies,

More information

HP Smart Array Controllers and basic RAID performance factors

HP Smart Array Controllers and basic RAID performance factors Technical white paper HP Smart Array Controllers and basic RAID performance factors Technology brief Table of contents Abstract 2 Benefits of drive arrays 2 Factors that affect performance 2 HP Smart Array

More information

StarWind Virtual SAN for Microsoft SOFS

StarWind Virtual SAN for Microsoft SOFS StarWind Virtual SAN for Microsoft SOFS Cutting down SMB and ROBO virtualization cost by using less hardware with Microsoft Scale-Out File Server (SOFS) By Greg Schulz Founder and Senior Advisory Analyst

More information

White Paper: M.2 SSDs: Aligned for Speed. Comparing SSD form factors, interfaces, and software support

White Paper: M.2 SSDs: Aligned for Speed. Comparing SSD form factors, interfaces, and software support White Paper: M.2 SSDs: Aligned for Speed Comparing SSD form factors, interfaces, and software support M.2 SSDs: Aligned for Speed A flurry of new standards activity has opened a wide range of choices for

More information

Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays

Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays Database Solutions Engineering By Murali Krishnan.K Dell Product Group October 2009

More information

QLogic 16Gb Gen 5 Fibre Channel in IBM System x Deployments

QLogic 16Gb Gen 5 Fibre Channel in IBM System x Deployments QLogic 16Gb Gen 5 Fibre Channel in IBM System x Deployments Increase Virtualization Density and Eliminate I/O Bottlenecks with QLogic High-Speed Interconnects Key Findings Support for increased workloads,

More information

VTrak 15200 SATA RAID Storage System

VTrak 15200 SATA RAID Storage System Page 1 15-Drive Supports over 5 TB of reliable, low-cost, high performance storage 15200 Product Highlights First to deliver a full HW iscsi solution with SATA drives - Lower CPU utilization - Higher data

More information

Post-production Video Editing Solution Guide with Microsoft SMB 3 File Serving AssuredSAN 4000

Post-production Video Editing Solution Guide with Microsoft SMB 3 File Serving AssuredSAN 4000 Post-production Video Editing Solution Guide with Microsoft SMB 3 File Serving AssuredSAN 4000 Dot Hill Systems introduction 1 INTRODUCTION Dot Hill Systems offers high performance network storage products

More information

3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering

3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering 3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering StarTech ID: PEXMSATA343 The PEXMSATA343 3-Port PCI Express 2.0 SATA Card with HyperDuo adds an internal

More information

The Transition to PCI Express* for Client SSDs

The Transition to PCI Express* for Client SSDs The Transition to PCI Express* for Client SSDs Amber Huffman Senior Principal Engineer Intel Santa Clara, CA 1 *Other names and brands may be claimed as the property of others. Legal Notices and Disclaimers

More information

Deploying Affordable, High Performance Hybrid Flash Storage for Clustered SQL Server

Deploying Affordable, High Performance Hybrid Flash Storage for Clustered SQL Server Deploying Affordable, High Performance Hybrid Flash Storage for Clustered SQL Server Flash storage adoption has increased in recent years, as organizations have deployed it to support business applications.

More information

Dell Microsoft Business Intelligence and Data Warehousing Reference Configuration Performance Results Phase III

Dell Microsoft Business Intelligence and Data Warehousing Reference Configuration Performance Results Phase III White Paper Dell Microsoft Business Intelligence and Data Warehousing Reference Configuration Performance Results Phase III Performance of Microsoft SQL Server 2008 BI and D/W Solutions on Dell PowerEdge

More information

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express SATA Controller Card enables 4 AHCI SATA III connections to

More information

Improving IT Operational Efficiency with a VMware vsphere Private Cloud on Lenovo Servers and Lenovo Storage SAN S3200

Improving IT Operational Efficiency with a VMware vsphere Private Cloud on Lenovo Servers and Lenovo Storage SAN S3200 Improving IT Operational Efficiency with a VMware vsphere Private Cloud on Lenovo Servers and Lenovo Storage SAN S3200 Most organizations routinely utilize a server virtualization infrastructure to benefit

More information

StorTrends RAID Considerations

StorTrends RAID Considerations StorTrends RAID Considerations MAN-RAID 04/29/2011 Copyright 1985-2011 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200 Norcross, GA 30093 Revision

More information

Virtualization of the MS Exchange Server Environment

Virtualization of the MS Exchange Server Environment MS Exchange Server Acceleration Maximizing Users in a Virtualized Environment with Flash-Powered Consolidation Allon Cohen, PhD OCZ Technology Group Introduction Microsoft (MS) Exchange Server is one of

More information

The Flash Transformed Data Center & the Unlimited Future of Flash John Scaramuzzo Sr. Vice President & General Manager, Enterprise Storage Solutions

The Flash Transformed Data Center & the Unlimited Future of Flash John Scaramuzzo Sr. Vice President & General Manager, Enterprise Storage Solutions The Flash Transformed Data Center & the Unlimited Future of Flash John Scaramuzzo Sr. Vice President & General Manager, Enterprise Storage Solutions Flash Memory Summit 5-7 August 2014 1 Forward-Looking

More information

Express5800 Scalable Enterprise Server Reference Architecture. For NEC PCIe SSD Appliance for Microsoft SQL Server

Express5800 Scalable Enterprise Server Reference Architecture. For NEC PCIe SSD Appliance for Microsoft SQL Server Express5800 Scalable Enterprise Server Reference Architecture For NEC PCIe SSD Appliance for Microsoft SQL Server An appliance that significantly improves performance of enterprise systems and large-scale

More information

Enterprise SSD Interface Comparisons

Enterprise SSD Interface Comparisons Technology Paper Enterprise SSD Introduction PCI Express () is a general purpose bus interface used both in client and enterprise compute applications. Existing mass storage interfaces (SATA, SAS) connect

More information

Essentials Guide CONSIDERATIONS FOR SELECTING ALL-FLASH STORAGE ARRAYS

Essentials Guide CONSIDERATIONS FOR SELECTING ALL-FLASH STORAGE ARRAYS Essentials Guide CONSIDERATIONS FOR SELECTING ALL-FLASH STORAGE ARRAYS M ost storage vendors now offer all-flash storage arrays, and many modern organizations recognize the need for these highperformance

More information

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine Virtual Fibre Channel for Hyper-V Virtual Fibre Channel for Hyper-V, a new technology available in Microsoft Windows Server 2012, allows direct access to Fibre Channel (FC) shared storage by multiple guest

More information

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V Copyright 2011 EMC Corporation. All rights reserved. Published February, 2011 EMC believes the information

More information

SUN ORACLE EXADATA STORAGE SERVER

SUN ORACLE EXADATA STORAGE SERVER SUN ORACLE EXADATA STORAGE SERVER KEY FEATURES AND BENEFITS FEATURES 12 x 3.5 inch SAS or SATA disks 384 GB of Exadata Smart Flash Cache 2 Intel 2.53 Ghz quad-core processors 24 GB memory Dual InfiniBand

More information

MaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products

MaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products MaxDeploy Ready Hyper- Converged Virtualization Solution With SanDisk Fusion iomemory products MaxDeploy Ready products are configured and tested for support with Maxta software- defined storage and with

More information

4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering

4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering 4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering StarTech ID: PEXSAT34RH The PEXSAT34RH 4-Port PCI Express 2.0 SATA Controller Card with HyperDuo adds 4 AHCI SATA III

More information

High Performance Tier Implementation Guideline

High Performance Tier Implementation Guideline High Performance Tier Implementation Guideline A Dell Technical White Paper PowerVault MD32 and MD32i Storage Arrays THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS

More information

Serial ATA in Servers and Networked Storage

Serial ATA in Servers and Networked Storage Serial ATA in Servers and Networked Storage Serial ATA (SATA) in Servers and Networked Storage Introduction Serial ATA (SATA) is a storage interface technology developed by a group of the industry s leading

More information

Microsoft SQL Server 2014 Fast Track

Microsoft SQL Server 2014 Fast Track Microsoft SQL Server 2014 Fast Track 34-TB Certified Data Warehouse 103-TB Maximum User Data Tegile Systems Solution Review 2U Design: Featuring Tegile T3800 All-Flash Storage Array http:// www.tegile.com/solutiuons/sql

More information

Data Center Solutions

Data Center Solutions Data Center Solutions Systems, software and hardware solutions you can trust With over 25 years of storage innovation, SanDisk is a global flash technology leader. At SanDisk, we re expanding the possibilities

More information

Solving I/O Bottlenecks to Enable Superior Cloud Efficiency

Solving I/O Bottlenecks to Enable Superior Cloud Efficiency WHITE PAPER Solving I/O Bottlenecks to Enable Superior Cloud Efficiency Overview...1 Mellanox I/O Virtualization Features and Benefits...2 Summary...6 Overview We already have 8 or even 16 cores on one

More information

Storage Synergies: Adaptec Series 5 Unified Serial Controllers and Seagate Barracuda ES.2 SAS Drives

Storage Synergies: Adaptec Series 5 Unified Serial Controllers and Seagate Barracuda ES.2 SAS Drives Storage Synergies: Adaptec Series 5 Unified Serial Controllers and Seagate Barracuda ES.2 SAS Drives A new generation of storage controllers and disk drives is now available, optimal for a growing class

More information

SLIDE 1 www.bitmicro.com. Previous Next Exit

SLIDE 1 www.bitmicro.com. Previous Next Exit SLIDE 1 MAXio All Flash Storage Array Popular Applications MAXio N1A6 SLIDE 2 MAXio All Flash Storage Array Use Cases High speed centralized storage for IO intensive applications email, OLTP, databases

More information

Frequently Asked Questions March 2013. s620 SATA SSD Enterprise-Class Solid-State Device. Frequently Asked Questions

Frequently Asked Questions March 2013. s620 SATA SSD Enterprise-Class Solid-State Device. Frequently Asked Questions March 2013 s620 SATA SSD Enterprise-Class Solid-State Device Frequently Asked Questions Frequently Asked Questions Q: What about advanced data protection? A: In mission-critical enterprise and datacenter

More information

SUN ORACLE DATABASE MACHINE

SUN ORACLE DATABASE MACHINE SUN ORACLE DATABASE MACHINE FEATURES AND FACTS FEATURES From 2 to 8 database servers From 3 to 14 Sun Oracle Exadata Storage Servers Up to 5.3 TB of Exadata QDR (40 Gb/second) InfiniBand Switches Uncompressed

More information

The Revival of Direct Attached Storage for Oracle Databases

The Revival of Direct Attached Storage for Oracle Databases The Revival of Direct Attached Storage for Oracle Databases Revival of DAS in the IT Infrastructure Introduction Why is it that the industry needed SANs to get more than a few hundred disks attached to

More information

Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance

Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance Hybrid Storage Performance Gains for IOPS and Bandwidth Utilizing Colfax Servers and Enmotus FuzeDrive Software NVMe Hybrid

More information

FlashSoft Software from SanDisk : Accelerating Virtual Infrastructures

FlashSoft Software from SanDisk : Accelerating Virtual Infrastructures Technology Insight Paper FlashSoft Software from SanDisk : Accelerating Virtual Infrastructures By Leah Schoeb January 16, 2013 FlashSoft Software from SanDisk: Accelerating Virtual Infrastructures 1 FlashSoft

More information

PARALLELS CLOUD STORAGE

PARALLELS CLOUD STORAGE PARALLELS CLOUD STORAGE Performance Benchmark Results 1 Table of Contents Executive Summary... Error! Bookmark not defined. Architecture Overview... 3 Key Features... 5 No Special Hardware Requirements...

More information

Dynamic Disk Pools Technical Report

Dynamic Disk Pools Technical Report Dynamic Disk Pools Technical Report A Dell Technical White Paper Dell PowerVault MD3 Dense Series of Storage Arrays 9/5/2012 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL

More information

Lenovo Database Configuration for Microsoft SQL Server 2016 45TB

Lenovo Database Configuration for Microsoft SQL Server 2016 45TB Database Lenovo Database Configuration for Microsoft SQL Server 2016 45TB Data Warehouse Fast Track Solution Data Warehouse problem and a solution The rapid growth of technology means that the amount of

More information

WHITE PAPER Addressing Enterprise Computing Storage Performance Gaps with Enterprise Flash Drives

WHITE PAPER Addressing Enterprise Computing Storage Performance Gaps with Enterprise Flash Drives WHITE PAPER Addressing Enterprise Computing Storage Performance Gaps with Enterprise Flash Drives Sponsored by: Pliant Technology Benjamin Woo August 2009 Matthew Eastwood EXECUTIVE SUMMARY Global Headquarters:

More information

SQL SOLUTION BRIEF. NexGen N5 for Microsoft SQL Server: Performance, Control and Consolidation

SQL SOLUTION BRIEF. NexGen N5 for Microsoft SQL Server: Performance, Control and Consolidation SOLUTION BRIEF NexGen N5 for Microsoft SQL Server: Performance, Control and Consolidation Database/OLTP applications today are typically a mission critical component of an organization and outages or delays

More information

QLogic 2500 Series FC HBAs Accelerate Application Performance

QLogic 2500 Series FC HBAs Accelerate Application Performance White Paper QLogic 2500 Series FC HBAs Accelerate Application Performance QLogic 8Gb HBAs: Planning for Future Requirements 8Gb Performance Meets the Needs of Next Generation Data Centers Key Findings

More information

Deploying Flash in the Enterprise Choices to Optimize Performance and Cost

Deploying Flash in the Enterprise Choices to Optimize Performance and Cost White Paper Deploying Flash in the Enterprise Choices to Optimize Performance and Cost Paul Feresten, Mohit Bhatnagar, Manish Agarwal, and Rip Wilson, NetApp April 2013 WP-7182 Executive Summary Flash

More information

Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays. Red Hat Performance Engineering

Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays. Red Hat Performance Engineering Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays Red Hat Performance Engineering Version 1.0 August 2013 1801 Varsity Drive Raleigh NC

More information

Reduce Latency and Increase Application Performance Up to 44x with Adaptec maxcache 3.0 SSD Read and Write Caching Solutions

Reduce Latency and Increase Application Performance Up to 44x with Adaptec maxcache 3.0 SSD Read and Write Caching Solutions MAXCACHE 3. WHITEPAPER Reduce Latency and Increase Application Performance Up to 44x with Adaptec maxcache 3. SSD Read and Write Caching Solutions Executive Summary Today s data centers and cloud computing

More information

2 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card w/ 2 msata Slots and HyperDuo SSD Tiering

2 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card w/ 2 msata Slots and HyperDuo SSD Tiering 2 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card w/ 2 msata Slots and HyperDuo SSD Tiering StarTech ID: PEXMSATA3422 The PEXMSATA3422 PCI Express SATA Card helps you improve the overall speed

More information

Business-centric Storage FUJITSU Hyperscale Storage System ETERNUS CD10000

Business-centric Storage FUJITSU Hyperscale Storage System ETERNUS CD10000 Business-centric Storage FUJITSU Hyperscale Storage System ETERNUS CD10000 Clear the way for new business opportunities. Unlock the power of data. Overcoming storage limitations Unpredictable data growth

More information