1 INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference Pump and Comfort Valve CS VW MH GM U P C 12" Supply Line and Adapters ANSI/NSF STD. 61 LISTED U P C ANSI/NSF 61 DRINKING WATER SYSTEM COMPONENTS MAXIMUM USE TEMPERATURE: 140 F Mfg. by Grundfos Pumps Warning Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product s failure and possible damage to property. Refer to enclosed warranty for operating parameters to ensure proper use with your water supply. Manual Edition: January 14, 2009
2 Thank you for your purchase. You are now the owner of a WATTS HOT WATER RECIRCULATION System. It has been carefully inspected and tested before shipment. It should give you long, efficient, trouble-free service. For maximum performance and reliability, please follow the simple instructions in this manual. NOTE: Please understand this is not an anti-scald device. You may have some warm water in your cold water line under the sink where the valve is installed. Once the cold water line is opened, the warm water will dissipate in a very short time. Table of Contents Package Contents... 2 Operational Parameters... 2 Pump Installation... 3 Sensor Valve Installation... 4 Sensor Valve Operation... 5 Electrical... 5 Timer Control Technical Data... 6 Timer Operation... 6 Warranty... 7 Package Contents Examine the components carefully to make sure no damage has occurred to the pump. Care should be taken to ensure the pump is NOT dropped or mishandled; dropping will damage the pump. Package Contains the following: 1 - Hot water recirculator pump with timer 1 - Sensor Valve 2 - Valve mounting screws 2-3/8 compression to 1/2" threaded flex hoses 2 - Adapters 2 - Rubber washers Installation and Operating Instructions Operational Parameters The maximum allowable water temperature is 150 degrees F for the circulator pump and timer. Page 2
3 PUMP INSTALLATION Water Heater Checklist Electric Water Heater Turn off Power to your Water Heater. (turn off power at breaker box) Gas Water Heater Turn off the Gas to your water heater and insure that the pilot light is not burning. Pump Mounting: For Indoor Use Only 1. Close the supply water valve to the water heater located, in most cases, above the water heater on the cold water inlet to the hot water heater. 2. Drain the water from the hot water pipe by opening a hot water faucet in the house. Let the water run until it stops flowing. Then drain remaining water from hot water heater spigot. Leave the faucet in the house open until pump installation is complete. If water does not stop flowing, check to make sure the water to the hot water heater has been completely shut off. Picture 1 DO NOT Mount Motor Shaft in Vertical Position disconnect 3. Disconnect the hot water heater at the hot water discharge. (see Picture #1) 4. Install pump onto the water heater discharge, using the 3/4" female fitting. The pump should be installed so that the pump is pumping away from the hot water heater, towards the house. Confirm the direction of pumping by observing the flow arrow on the side of the pump housing (See Picture #2). Be sure that the pump is not touching the exhaust vent piping (chimney) of a gas or oil fired hot water heater. 5. Connect the hot water line to the 3/4" NPT discharge of the pump. Use pipe dope or Teflon tape to seal threads when connecting to a 3/4 female NPT connection. If a gasketed flexible copper water heater connector is used, pipe dope or Teflon tape is not required. Picture 2 direction of water 6. Reopen the supply valve to the hot water heater and allow the water to run until all the air has been purged from the piping. 7. Close faucet inside the house. 8. Plug the line cord of pump into a 115V outlet. Be sure to route the power cord so that it does not touch the exhaust vent piping of a gas or oil fired hot water heater. 9. Using the timer (see pg. 6), set the pump to operate around your peak use times. (ie. 30 minutes before the first shower until 15 minutes after last shower). Page 3
4 Sensor Valve Installation Sensor Valve Location For the greatest effect, the valve should be located at a faucet with the greatest piping distance from the hot water heater. If your home has a branched hot water line, more than one Sensor Valve may be necessary. Additional Sensor Valve kits can be found at some retail locations as well as the WATTS website at or by calling toll free at (800) NOTE: Do not use Teflon tape or pipe dope on the Sensor Valve threads. 3/8" Stop Valve Installation 1. Close both the hot and cold stop valves below the sink (see Picture 3). 2. Place supplied rubber washers in female end of adapters. Attach adapters to both Cold Water Out and Hot Water Out ports of Sensor Valve. Finger tight plus a quarter turn with wrench. 3. Disconnect existing supply line connection from both hot and cold stop valves and then connect to adapter, attach to Sensor Valve (see Picture 4). 4. Connect the new 1/2" x 3/8" flex hose to the hot water stop valve (3/8" side) and the Hot Water In port (1/2" side) of the Sensor Valve (see Picture 5 & 6). Connect the remaining 1/2 x 3/8 flex hose to the cold water stop valve. 5. Open both the hot water and cold water stop valves. 6. If desired, Sensor Valve can be mounted to the wall with the mounting screws (see Figure 1). Picture 3 Picture 4 1/2" or Other Stop Valve Installation 1. Close both the hot and cold stop valves below the sink (see Picture 3). 2. Place supplied rubber washers in female end of adapters. Attach adapters to both Cold Water Out and Hot Water Out ports of Sensor Valve. Finger tight plus a quarter turn with wrench. 3. Disconnect existing supply line connection from faucet connection leave stop valve connection in place. Take disconected end and attach to Hot Water In and Cold Water In connections respectively 4. Connect the new 1/2" x 3/8" flex hose to the already installed adapter (on Sensor Valve) (3/8" side) and the faucet connection (1/2 side) for both Hot Water and Cold Water respectively (see Picture 5 & 6). 5. Open both the hot water and cold water stop valves. 6. If desired, Sensor Valve can be mounted to the wall with the mounting screws (see Figure 1). Picture 5 Hot Water In Hot Water Out Cold Water Out Cold Water In Page 4
5 SENSOR VALVE OPERATION Correct Installation If there is no hot water at the faucet or there appears to be too much hot water on the cold water side the following steps will determine if the valve is operating correctly: 1. Close the cold water stop valve below the sink. Hot Out Hot In Cold Out Cold In 2. Open the cold water faucet. 3. Water should slowly flow from the faucet until hot water reaches the valve. The flow should gradually decrease until no water is coming from the faucet at which time the valve is closed. ELECTRICAL Figure 1 Incorrect Installation SAFETY WARNING WARNING - Risk of electrical shock - This pump is supplied with a grounding conductor. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded grounding type receptacle. The safe operation of this pump requires that it be grounded in accordance with the National Electrical Code and local governing codes and regulations. Electrical Requirements The operating voltage and other electrical data are marked on the motor label. Make sure that the motor is suitable for the electrical supply on which it will be used. Electrical Connection Insert the 115V plug on the line cord from the pump into a properly grounded 115V outlet. TIMER CONTROL TECHNICAL DATA Supply Voltage: 120 VAC, 60Hz Shortest Switching Interval: 15 minute increment Switch Modes: Timer, ON Override, OFF Override Protection: Clear plastic cover for dust and moisture protection of the clock face. Timer Technical Application The timer control is designed only for use with the specified WATTS INSTANT HOT WATER RECIRCULATING SYSTEM. Installed indoors on hot water service systems. The timer control is designed to turn the circulator on and off at preset times, allowing the user to select operation of the circulator during high use periods of the day. Page 5
6 TIMER OPERATION NOTE: Before the circulator is started, the water system must be filled with water and vented. Triangle Marker Manual Switch The timer has three modes of operation controlled by a manual switch: 1) OFF position: No pumping - circulator off The timer will still keep time of day 2) TIMER position: Circulator controlled by programing tab settings "ON or OFF" 3) ON position: Circulator in continuous pumping mode 24-hours/day 7-days a week Programing Tabs Time Setting NOTE: DO NOT SET THE TIME BY ROTATING OUTER DIAL. TO SET THE CURRENT TIME, TURN THE MINUTE HAND CLOCKWISE. Turn the minute hand clockwise until time of day on the outer dial is aligned with the triangle marker on the inner dial. Example for 10:30 AM. Turn the minute hand clockwise until 10:30 AM is aligned with the triangle on the inner dial. The hour and the minute dial will show exactly 10:30. Programming 24-Hour (Timer manual switch position) The 24-Hour dial has quarter-hour division tabs plus AM/PM indications. Set the required "ON/OFF" times on the programing ring by pushing the tabs away from or towards the center of the ring. Tabs pushed away from the center ring indicate circulator "ON" while tabs pushed towards the center ring indicate circulator is switched "OFF". The circulator will now start/stop according to the settings of the programming tabs. In case of power outage the timer will not keep time. Repeat time setting step when power is restored. Page 6
7 Limited Warranty What your Warranty Covers: If any part of your WATTS INSTANT HOT WATER RECIRCULATING SYSTEM is defective in workmanship, return unit after obtaining a return authorization (see below), within 12 months from original retail purchase. WATTS will repair or, at WATTS option, replace the unit. How to obtain Warranty Service: For warranty service, call for a return authorization number. Then, ship your unit to our factory, freight and insurance prepaid, with proof of date of original purchase. Please include a note stating the problem. WATTS will repair it, or replace it, and ship it back to you prepaid. What this warranty does not cover: This warranty does not cover defects resulting from improper installation, (contrary to WATTS printed instructions), from abuse, misuse, misapplication, improper maintenance, neglect, alteration, accidents, casualties, fire, flood, freezing, environmental factors, water pressure spikes or other such acts of God. This warranty will be void if defects occur due to failure to observe the following conditions: 1. The WATTS INSTANT HOT WATER RECIRCULATING SYSTEM Water System must be hooked up to a potable municipal or well water supply. This warranty does not cover any equipment that is relocated from the site of its original installation. This warranty does not cover any equipment that is installed or used outside the United States of America and Canada. LIMITATIONS AND EXCLUSIONS: WATTS WILL NOT BE RESPONSIBLE FOR ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE. WATTS WILL NOT BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING TRAVEL EXPENSE, TELEPHONE CHARGES, LOSS OF REVENUE, LOSS OF TIME, INCONVENIENCE, LOSS OF USE OF THE EQUIPMENT, AND DAMAGE CAUSED BY THIS EQUIPMENT AND ITS FAILURE TO FUNCTION PROPERLY. THIS WARRANTY SETS FORTH ALL OF WATTS RESPONSIBILITIES REGARDING THIS EQUIPMENT. YOUR RIGHTS UNDER STATE LAW: Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply. This warranty gives you specific legal rights, and you may have other legal rights which vary from state to state. CALIFORNIA PROPOSITION 65 WARNING WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. ( California law requires this warning to be givin to customers in the State of California.) For more information: prop65
8 LUPTLW04 01/09 PRINTED IN USA Phone: Fax:
INSTANT HOT WATER RECIRCULATING SYSTEM
INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure
Comfort Series Instant Hot Water System
GRUNDFOS INSTRUCTIONS Installation and Operation Comfort Series Instant Hot Water System ANSI/NSF61 and AIPMO approved Shipment Inspection page 1. Pre-Installation Checklist page 1. Pump Mounting page
Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping
Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November
Series 9000 Water Treatment System
Series 9000 Water Treatment System Owners Manual Installation Service & Parts Operation Guide The Clear Choice for Soft, Conditioned Water TABLE OF CONTENTS Page Pre-Installation Review --------------------------------------------------------------------------------
USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2
Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
Laing Thermotech. Autocirc The Instant Hot Water Pump ACT-303/353-BTW and ACT-303/353-BTRW. Installation & Operating Manual. Instruction Manual
Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
1.5. Precautions Drain the moisture from the tank daily to help prevent corrosion.
Compressor Specifications Model Number Horse Power Tank Capacity Gallons/Liters APC4406 1.5 4.6 Gallon Voltage/Amps/Phase 120/2.6/1 Kick-In Pressure 85 Kick-Out Pressure 115 WARNING! The power cord on
L-5 Liter Outdoor Tankless Water Heater
8. Turn the spray nozzle to the on and adjust to the desired water pattern on the shower head. 9. There will be a series of audible clicks and the burner will ignite. (Should the burner not ignite after
MODEL INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.
Utility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
OWNERS MANUAL ECOJET
OWNERS MANUAL ECOJET ECO-JET Self-priming pumps ideal for supplying water for domestic and irrigation applications. 1) 1 Suction 2) 1 Discharge 3) Fill Plug 4) Drain Plug Fig. A 115V/60Hz Dear Customer,
TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER
TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
concessionstands.com
OWNERS MANUAL MODEL: 30 HOTDOG Roller Grill PART NUMBER: 6 2030 115 volts, 60 hz WARNING ELECTRICAL SHOCK HAZARD. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH. 1. Electrical
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Compool. Lx220 SOLAR CONTROL SYSTEM. Installation & Operating Instructions 03/22/
Compool Lx220 SOLAR CONTROL SYSTEM Installation & Operating Instructions 03/22/00 941-0809 Compool Lx220 1 Table of Contents Table of Contents........................................................ 1
Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)
Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
DuraMAC TM. Water Pressure Booster System Installation Instructions
DuraMAC TM Water Pressure Booster System Installation Instructions The DuraMAC Water Pressure Booster System is the first booster pump of its kind to be designed for virtually all residential and small
32 Fiberglass Tank In-Ground Sand Filter Aquapro Systems
32 Fiberglass Tank In-Ground Sand Filter Aquapro Systems 877-278-2797 www.ecoaquapro.com GENERAL NOTES 1. When unpacking the filter, be sure the unit is complete and no visible shipping damage has occurred.
GLOBE FLOWCELL. Operating Manual. ROLA-CHEM Flowcell PN /17/2015 page: 1 of 8
GLOBE FLOWCELL Operating Manual ROLA-CHEM Flowcell PN 550182 09/17/2015 page: 1 of 8 Table of Contents Section title Page 1. Safety Instructions 2 2. Description 2 3. Installation 3 4. Use of Flowcell
SUPERPLUS WATER FILTRATION SYSTEM
SUPERPLUS WATER FILTRATION SYSTEM For Model #: SP20-2, SP40-2 INSTRUCTIONS/ASSEMBLY USE AND CARE MANUAL (Important: Read this manual thoroughly before install) TABLE OF CONTENTS 2 3 4 6 8 9 10 11 12 General
Installation Instructions / Warranty
Installation Instructions / Warranty Interaktiv and Retroaktiv Centerset Lavatory Faucets Widespread Lavatory Faucets Retroaktiv Centerset Lavatory Faucets 00XXX Tango with Cross Handles 008XXX Tango with
SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE
Eemax Inc., 353 Christian Street, Oxford, CT 06478 1 E ema X SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE WARNING
Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity
WATER HEATER THERMAL EXPANSION TANKS Owner s Manual Safety Instructions Installation Maintenance Warranty Models: 2-5 Gallon Capacity Thank You for purchasing this Thermal Expansion Tank. Properly installed
For Models #6-5001, #6-7501, #10-7501 & #10-12K1
EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE
TABLE OF CONTENTS. General Warnings Installation Programming System Start-Up Frequently Asked Questions...
Service Manual Table of Contents TABLE OF CONTENTS Page General Warnings... 3 Installation... 5 Programming... 7 System Start-Up... 8 Frequently Asked Questions... 10 Drawings and Part Numbers... 11 Front
90C COMPRESSOR KIT PART NO C COMPRESSOR KIT PART NO C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO.
90C COMPRESSOR KIT PART NO. 00090 92C COMPRESSOR KIT PART NO. 00092 95C COMPRESSOR KIT 12V PART NO. 00095 95C COMPRESSOR KIT 24V PART NO. 02495 90C 92C 95C IMPORTANT: It is essential that you and any other
FD-1200 & FD-2000 Exacto-flow Flow Divider Parts & Instruction Manual
FD-1200 & FD-2000 Exacto-flow Flow Divider Parts & Instruction Manual CDS-John Blue Company Division of Advanced Systems Technology 290 Pinehurst Dr., Huntsville AL 35806 PO Box 1607, Huntsville AL 35807
Utopian Portable A/C
Utopian Portable A/C Thank you for purchasing this quality Portable A/C system! Please read through this manual completely, and keep it in case you need to reference the information in the future. Any
tire inflator with pressure gauge
tire inflator with pressure gauge Model 95583 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks
Installation and Operating Instruction Manual
Electric Mini Tank Water Heaters CMT-1.3 CMT-2.5 CMT-4.0 CMT-ST70 Tempering valve Optionally available Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric
OWNER'S MANUAL FLO-MASTER "XP2" SERIES PUMPS
OWNER'S MANUAL FLO-MASTER "XP2" SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
GL-235 Solar Pool Controller
GL-235 Solar Pool Controller Installation & Operation Manual for models GL-235-LV GL-235-LV-HV G LDLINE CONTROLS INC. North Kingstown, RI USA www.goldlinecontrols.com 888-921-7665 Description The GL-235-LV
INSTALLATION INSTRUCTIONS. SharkBite. Connection System. The SharkBite System
INSTALLATION INSTRUCTIONS SharkBite Connection System The SharkBite System The SharkBite connection system uses an advanced push-fit design that works in two stages. When the tube is inserted into the
gamma uv Aquarium Ultraviolet Sterilizers
gamma uv Aquarium Ultraviolet Sterilizers Instructions for Models #1400 8w, 1401 15w, 1402 25w Important Safety Instructions... Page 2 Installation... Page 3 8/15/25 watt Alternate Diagrams... Page 5 25
Bottled Water Dispenser User Manual
MOGUL Bottled Water Dispenser User Manual 1 2 3 4 1 Touch Guard Hot Water Faucet 2 Cold Water Faucet 3 Cook Water Faucet (room Temperature Water) 4 Drip Tray Parts may not appear exactly as shown THANK
Mini Submersible / Fountain / Pond Pump
Mini Submersible / Fountain / Pond Pump Item 68372 Item 68389 Item 68393 Item 68395 Item 68396 Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL.
4 in 1 Air Compressor
4 in 1 Air Compressor Operating Instructions and Parts Manual Model W-1704! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
NELSON HEAT TRACING SYSTEMS SPECIFICATION / APPLICATION
DESCRIPTION Electrical Specifications Functional Operating temperature +3 C (38 F +/-1 F) Power switch OFF temperature +45 C (112 F) Power switch ON temperature +30 C (86 F) Environmental Working temperature
Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H
HR SERIES HEAT RECOVERY VENTILATOR (HRV) Home Owners Guide Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR100V HR160H & HR220H READ AND SAVE THIS GUIDE PP0924 09/2013 ABOUT S&P S&P is the world's
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
gamma uv Ultraviolet Sterilizers
gamma uv Ultraviolet Sterilizers Instructions for Models #1400 8w, 1401 15w, 1402 25w Important Safety Instructions... Page 2 Installation... Page 3 8/15 watt Alternate Diagrams... Page 5 25 watt Diagram
MAC FAUCETS. Owner s Manual. Models: FA444
MAC FAUCETS Owner s Manual Models: FA444 Installation procedure: 1. Take a moment to view drawings and read special Installation note on page 3 of this manual before proceeding with installation. Connect
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
FAUCET SPECIFICATIONS. Vessel Bathroom Faucet Model VG03023 MODEL VG03023
FAUCET SECIFICATIONS Vessel Bathroom Faucet Model VG03023 MODEL VG03023 FEATURES Solid brass construction Single hole construction Ceramic disk cartridge Single lever faucet Standard plumbing connections
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual
Mini Tank Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General Information 3/6 Technical
CEILING FAN REMOTE CONTROLLER INSTALLATION AND OPERATION INSTRUCTION. Safety information General guide Function chart...
CEILING FAN REMOTE CONTROLLER INSTALLATION AND OPERATION INSTRUCTION CONTENTS Safety information... 1 General guide... 2 Function chart... 3 Remote control setting (Dimming/Non Dimming)... 3 Installation
Operating Instructions and Parts Manual. Rout-R-Lift FX
Operating Instructions and Parts Manual Rout-R-Lift FX Models: 02303A, 02303A, 02304A, & 02305A JessEm Tool Company, LTD 61 Forest Plain Road Orillia, Ontario, Canada L3V 6H1 705-726-8233 705-327-0295
200 PSI COMPRESSORS - MODEL NUMBERS
200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read
Electric Water Heater
Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
Global Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 11257 Coloma Road Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Insertion Flow Meter: IF200-1 - Congratulations on your purchase of the
AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power
VEC173 ONE YEAR LIMITED WARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, regarding this product.
Do not extend the hot water outlet tube. Minimum working pressure: 220kPa (system might not work properly if the pressure is below the requirement).
XSENTIAL X-301 INSTANT HOT WATER DISPENSER INSTALLATION & OPERATING GUIDE 1.0 Components: When you purchase the Diana Instant Hot Water tank, contents include: 1. X-301 boiler 2. DLX-580 faucet 3. Feed
AIR FILE W/4-PIECE FILE SET MODEL 1704 ASSEMBLY AND OPERATING INSTRUCTIONS
AIR FILE W/4-PIECE FILE SET MODEL 1704 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from product described herein. 3491 Mission Oaks Blvd. Camarillo,
1in. Clear Water Pump OWNER'S MANUAL
1in. Clear Water Pump OWNER'S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172
Model # 900172: Page 1 USER MANUAL Bottom Loading Bottled Water Dispenser Model # 900172 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING
DEHUMIDIFIER MODELS: SD-30E / SD-40E / SD-60E INSTRUCTION MANUAL
DEHUMIDIFIER MODELS: SD-30E / SD-40E / SD-60E INSTRUCTION MANUAL Please read these instructions thoroughly and keep it in a safe place for future reference. CONTENTS FUNCTIONS 2 SAFETY NOTES 2 NAME OF
280C AIR COMPRESSOR KIT
280C AIR COMPRESSOR KIT PART NO. 28021 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product.
8 Gallon Twin Tank Air Compressor
Item No. APC4007 TM Owner s Manual 8 Gallon Twin Tank Air Compressor Please read and save these instructions. HAVE QUESTIONS OR NEED SERVICE DO NOT RETURN TO STORE! PLEASE CALL TOLL FREE: 888.896.6881
INSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION
OPERATING INSTRUCTIONS Shortening Filter Model No. 99-A, 102-A, & 107-A Series TABLE OF CONTENTS PAGE Installation... 2 Operating... 3 Cleaning... 5 Parts List... 6 & 7 Troubleshooting... 8 LIMITED WARRANTY
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS 1. WARNING To guard against injury, basic safety precautions should be observed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. DANGER To avoid possible
1 HP Swimming pool PUMP
1 HP Swimming pool PUMP 67333 Set up and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury.
OPERATING INSTRUCTIONS
GAS CONTINUOUS FLOW WATER HEATERS OPERATING INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60 GAS CONTINUOUS FLOW 2 OPERATING INSTRUCTIONS
RCST Standard Thermostatic On/Off Remote Control INSTALLATION AND OPERATING INSTRUCTIONS
RCST Standard Thermostatic On/Off Remote Control INSTALLATION AND OPERATING INSTRUCTIONS This wireless thermostatic on/off/ remote control system provides a safe, reliable, and user-friendly remote control
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Air Release Valve Series 38, 45, 50 (Compound Lever Type)
Manual No. ARCL-OM1-1 Air Release Valve Series 38, 45, 50 (Compound Lever Type) Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1
OPERATORS MANUAL MG0012 MEAT & FOOD GRINDER MG0012/0209 ED
OPERATORS MANUAL MG0012 MEAT & FOOD GRINDER MG0012/0209 ED 1 0011112 TO INSURE BOTH SAFE AND TROUBLE-FREE PERFORMANCE, WE STRESS THAT ALL PERSONNEL THAT WILL BE INVOLVED WITH YOUR NEW UNIVEX MEAT GRINDER
Electric Mini Tank Water heaters GL 2.5 - GL 4 - GL 6+
Electric Mini Tank Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric shock or injury to
325C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO.
325C AIR COMPRESSOR KIT PART NO. 32530-32533 - 32534-32538 350C AIR COMPRESSOR KIT PART NO. 35030-35033 400C AIR COMPRESSOR KIT PART NO. 40040 450C AIR COMPRESSOR KIT PART NO. 45040 325C 350C 400C 450C
Heater with Humidifier Model SH-1506 USER MANUAL
Heater with Humidifier Model SH-1506 USER MANUAL CREATING A CLEAN, HEALTHY LIVING ENVIRONMENT FOR YOU AND YOUR FAMILY. LOCATION OF KEY PARTS AND CONTROLS Control Panel Drain Hole Water Level Indicator
Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.
Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver. OWNER'S MANUAL VR36A XC18A XM13A MODEL VK69A (INCLUDES XC18A CAMERA, XM13A
Installation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual Fusion Upflow Calcite Filter ph Neutralizer Filter 111-UFF-Cal-1 111-UFF-Cal-2 111-UFF-Cal-3 111-UFF-Cal-4 US Water Systems, Inc. 1209 Country Club Road Indianapolis,
11104 & Installation Instructions
11104 & 11110 Installation Instructions WARNING! The fuel system is under pressure. Do not open the fuel system until the pressure has been relieved. Refer to the appropriate vehicle service manual for
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
Operation Manual. Magnetically coupled centrifugal pump. Ocean Runner OR 1200 Ocean Runner OR 2500 Ocean Runner OR 3500 Ocean Runner OR 6500
Operation Manual Magnetically coupled centrifugal pump OR 1200 OR 2500 OR 3500 OR 6500 Circulation pumps for fresh and salt water aquariums. In purchasing this pump you have selected a top quality product.
Air. (Simple Models DESCRIPTION INSTALLATION REASSEMBLY WARRANTY... 5 VAL-MATIC
Manual No. ARSL-OM1-2 Air Releasee Valve (Simple Lever Type) Models 15A, 22, 25 Operation, Mainte enance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION...
MANUFACTURING NUMBERS: COUNTERTOP MERCHANDISER NIT A T C L T US L I S T E D. P/N Rev. B 01/12. Model CTD-24.
CM MANUFACTURING NUMBERS: 9800100 9800104 9800106 C L I S T E D US SA L NIT A T I S T E ION D COUNTERTOP MERCHANDISER Model CTD-24 Owner s Manual COUNTERTOP MERCHANDISER (CTD-24) Owner Information...2
Owner s Manual. Calcite ph Neutralizer
Owner s Manual Page 2 Copyright 2012 Enviro Water Solutions Inc. All rights reserved. All information contained herein is the property of Pelican Water Systems. Pelican Water Systems makes no warranty
1.888.339.2546 (press 135 at any time) Monday through Friday, 8am to 5:00pm MST
SolarPRO Pool HEATER Owner s Manual MODEL 4513 IMPORTANT safety rules Read all instructions BEFORE assembling and using this product. KEEP THIS MANUAL. IMPORTANT DO NOT Return product to store For technical
1/3 HP Submersible Sump Pump with Vertical Float Switch
1/3 HP Submersible Sump with Vertical Float Switch Item 68476 Specifications Float Switch Operation Height 7.1 IN. ON / 2.8 IN. OFF Electrical Requirements 120V~ / 60Hz / 7.6A Power Length Maximum Capacity
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
CABLE MODEM QUICK START
CABLE MODEM QUICK START This Quick Start describes how to connect your Zoom cable modem to a cable modem service. This lets your cable modem provide Internet access to a computer or other device connected
MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater.
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-10/13 FILTERS with the 253/742 Logix Control Valve June 2010 Table of Contents Page No. Topic Description 1 Model
TRANQUILITY ADVANCED HEATING SYSTEM
TRANQUILITY ADVANCED HEATING SYSTEM MODELS: PBES-6010 PBES-6040 1000W Advanced Heating System 4000W Advanced Heating System Operation / Installation Instructions 85-0059 Rev.05-12/11 INTRODUCTION The
PREPSAVER MANUAL OPERATOR S MANUAL
PREPSAVER MANUAL OPERATOR S MANUAL 4509-4510-4512 Persons under age 18 are not permitted to operate or have accessibility to operate this equipment per U.S. Dept. Of Labor Employment Standards Administration
Installation Instructions / Warranty
Installation Instructions / Warranty Vertical Spray Bidet Fitting Rough 1322X181 Citterio 39224xx0 Citterio 39225xx0 Starck 10220xx0 Steel 35220800 Uno 38220xx0 Terrano 37224xx0 Terrano 37225xx0 Carlton
Electric Mini Tank Water Heaters WM-2.5 & WM-4.0
Electric Mini Tank Water Heaters WM-2.5 & WM-4.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 2 Technical Data 3-4 General Information 5 Technical Description
TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation
GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation
S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN
S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN AUTOMATIC S33A1 & S33A1C R WARNING risk of electric shock.
Installation Instructions
Installation Instructions Thank you very much for purchasing PIAA product. Please read this entire manual before installation and use of this product. For Installers Please give this Installation Manual
Mini 3, Mini 4, Mini 6
Mini 3, Mini 4, Mini 6 English TANKLESS ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER AND ELECTRICIAN English................................. 2-6 Warranty.................................