A Test Lab Techno Corp.

Size: px
Start display at page:

Download "A Test Lab Techno Corp."

Transcription

1 EMF ASSESSMENT REPORT Product Name : 3G Wireless Router Applicant : Shenzhen StrongRising Electronics Co.,Ltd Address : Room ,6th floor,innovation and Technology Park 13 buliding,shangsha,futian District, Shenzhen,China Trade Mark : N/A Model Number : AW930,AW920,AW926 Test Specification : EN62311:2008 EN50385:2002 Issue Date : 28, September 2013 Issue by A Test Lab Techno Corp. No , Changan Street, Bade City, Taoyuan County 334, Taiwan R.O.C. Tel: / Fax: Taiwan Accreditation Foundation accreditation number: 1330 Note: This report shall not be reproduced except in full, without the written approval of A Test Lab Techno Corp. This document may be altered or revised by A Test Lab Techno Corp. personnel only, and shall be noted in the revision section of the document. The client should not use it to claim product endorsement by TAF, or any government agencies. The test results in the report only apply to the tested sample. Page 1 of 11

2 Revision History Rev. Issue Date Revisions Revised By 00 28, September 2013 Initial Issue Page 2 of 11

3 Verification of Compliance Issued Date: 2013/09/28 Product Name Applicant : 3G Wireless Router : Shenzhen StrongRising Electronics Co.,Ltd Address : Room ,6th floor,innovation and Technology Park 13 buliding,shangsha,futian District, Shenzhen, China Trade Name Model Number EUT Rated Voltage Applicable Standard Test Result Performing Lab. : N/A : AW930,AW920,AW926 : Battery 3.7 V : EN62311:2008 EN50385:2002 : Complied : A Test Lab Techno Corp. No , Changan Street, Bade City, Taoyuan County 334, Taiwan R.O.C. Tel: / Fax: Taiwan Accreditation Foundation accreditation number: The above equipment has been tested by A Test Lab Techno Corp., and found compliance with the requirements set forth in the R&TTE Directive 1999/5/EC and technical standards mentioned above. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Approved By : Reviewed By : (Manager) (Yung Tan Tsai) (Testing Engineer) (Eric.lee) Page 3 of 11

4 TABLE OF CONTENTS 1 General Information EUT Description Test Site Environment Method of measurement Applicable Standard Technical Requirements Specification in EN Technical Requirements Specification in EN Test Result Conclusion Page 4 of 11

5 1 General Information 1.1. EUT Description Applicant Applicant Address Manufacturer Manufacturer Address Product Type Trade Name Shenzhen StrongRising Electronics Co.,Ltd Room ,6th floor,innovation and Technology Park 13 buliding,shangsha,futian District, Shenzhen,China Dongguan Branch of Shenzhen StrongRising Electronics Co.,Ltd Qingping Road No.2 Qinghutou Village Tangxia Town,Dongguan city,guangdong Province,China 3G Wireless Router N/A Model Number AW930,AW920,AW926 The only difference between AW930,AW920 and AW926 is the model name due to Model Difference market requirement. IMEI Number IMEI: GSM 900 (E-GSM): 880 MHz 915 MHz (TX); 925 MHz 960 MHz (RX); DCS1800: 1710 MHz 1785 MHz (TX); 1805 MHz 1880 MHz (RX); Operating Frequency WCDMA BAND I:1920~1980 MHz (TX), 2110 ~ 2170 MHz (RX); WCDMA BAND Ⅷ:880 MHz 915 MHz (TX); 925 MHz 960 MHz (RX); Wi-Fi: 2412~2472 MHz (TX/RX); GSM Internal antenna Type of Antenna WCDMA wifi Internal antenna Internal antenna 1.2. Test Site Environment Items Required (IEC 68-1) Actual Temperature ( C) Humidity (%RH) Barometric pressure (mbar) Page 5 of 11

6 2 Method of measurement 2.1. Applicable Standard EN62479:Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz 300 GHz) EN50385: Product Standard to Demonstrate the Compliances of Radio Base Stations and Fixed Terminal Stations for Wireless Telecommunication Systems with the Basic Restrictions or the Reference Levels Related to Human Exposure to Radio Frequency Electromagnetic Fields (110 MHz - 40 GHz) - General Public The electronic and electrotechnical apparatus shall comply with the basic restriction as specified in Annex II of Council Recommendation 1999/519/EC Technical Requirements Specification in EN General Description of Applied Standards EN Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz 300 GHz) is to demonstrate the compliance of apparatus with the basic restrictions or reference levels on exposure of the general public related to electric, magnetic, electromagnetic fields as well as induced and contact current. Limit: According to EN 62311, the criteria listed in the below table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified table 2 of Council Recommendation 1999/519/EC. Page 6 of 11

7 Frequency Range Reference levels for electric, magnetic and electromagnetic fields (0 Hz to 300 GHz, unperturbed rms values) E-field (V/m) H-field (A/m) B-field (µt) Equivalent plane wave Power Density Seq (W/m2) 0-1 Hz x x Hz x 10 4 / f 2 4 x 10 4 / f Hz /f 5000/f khz 250/f 4/f 5/f khz 250/f khz MHz /f 0.92/f MHz 87/f 1/2 0.73/f 0.92/f MHz MHz f 1/ f 1/ f 1/2 f/ GHz Notes: 1. ƒ as indicated in the frequency range column. 2. For frequencies between 100 khz and 10 GHz, Seq, E 2, H 2, and B2 are to be averaged over any six-minute Period. 3. For frequencies exceeding 10 GHz, Seq, E 2, H 2, and B2 are to be averaged over any 68/ƒ minute period (ƒ in GHz). 4. No E-field value is provided for frequencies < 1 Hz, which are effectively static electric fields. For most people the annoying perception of surface electric charges will not occur at field strengths less than 25 kv/m. Spark discharges causing stress or annoyance should be avoided. Assessment methods Page 7 of 11

8 2.3. Technical Requirements Specification in EN This standard is limited to apparatus which is intended for use by the general public as defined in the Council Recommendation 1999/519/EC of 12 July 1999 on the limitation of exposure of the general public to electromagnetic field (0 Hz to 300 GHz)(Official Journal L199 of 30 July 1999). This generic standard applies to electronic and electrical apparatus for which no dedicated product-or product family standard regarding human exposure to electromagnetic fields applies. This generic standard does not cover equipment, which fulfils the requirements given in EN or is medical equipment as defined in the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices. The frequency range covered is 0 Hz to 300 GHz. The object of this standard is to demonstrate the compliance of such apparatus with the basic restrictions or reference levels on exposure of the general public related to electric, magnetic, electromagnetic fields and contact current. Limit According to EN 50385: 2002, the criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified 1999/519/EC. Frequency Range Reference levels for electric, magnetic and electromagnetic fields (0 Hz to 300 GHz, unperturbed rms values) E-field (V/m) H-field (A/m) B-field (µt) Equivalent plane wave Power Density Seq (W/m2) 0-1 Hz x x Hz x 10 4 / f 2 4 x 10 4 / f Hz /f 5000/f khz 250/f 4/f 5/f khz 250/f khz MHz /f 0.92/f MHz 87/f 1/2 0.73/f 0.92/f MHz MHz f 1/ f 1/ f 1/2 f/ GHz Page 8 of 11

9 Notes: 1. ƒ as indicated in the frequency range column. 2. For frequencies between 100 khz and 10 GHz, Seq, E 2, H 2, and B2 are to be averaged over any six-minute Period. 3. For frequencies exceeding 10 GHz, Seq, E 2, H 2, and B2 are to be averaged over any 68/ƒ minute period (ƒ in GHz). 4. No E-field value is provided for frequencies < 1 Hz, which are effectively static electric fields. For most people the annoying perception of surface electric charges will not occur at field strengths less than 25 kv/m. Spark discharges causing stress or annoyance should be avoided. Assessment methods According to EN 50385: 2002, far field calculation method will be applied to the EUT. The antenna of the product, under normal use condition is at least 300cm away from the body of the user. Warning statement to the user for keeping at least 300cm separation distance and the prohibition of operating to a person has been printed on the user s manual. So, this product under normal use is located on electromagnetic far field between the human bodies. According to EN 50385: 2002, the far field calculation formula is Where: P = Input Power of the antanna (W) G = antenna gain relative to an isotropic antenna(numeric) θ,ф = elevation and azimuth angles to point of investigation r = distance from observation point to the antenna(m) ηo = characteristic impedance of free space D = antenna of length (m) Page 9 of 11

10 3 Test Result For WiFi: Mode Frequency (MHz) Output Power (dbm) Output Power (W) E-Field (V/m) E-Field Limit (V/m) Result b Pass g Pass n-HT Pass Standard applied EN62311: n-HT Pass Note: Antenna Gain (numeric): for WiFi antenna. The distance from observation point to the antenna is over 20 cm. For GSM&WCDMA: Mode Frequency (MHz) Output Power (dbm) Output Power (W) E-Field (W/m2) E-Field Limit (W/m2) Result GSM Pass DCS Pass WCDMA Band I Pass Standard applied EN50385:2002 WCDMA Band Ⅷ Pass Note: Antenna Gain (numeric): 1.000for GSM&WCDMA antenna The distance from observation point to the antenna is over 20 cm. Page 10 of 11

11 4 Conclusion The measurement results comply with the relevant limits for general public exposure specified as reference levels in the Council Recommendation 1999/519/EC....End of Report... Page 11 of 11

Radio Frequency Exposure Test Report

Radio Frequency Exposure Test Report Radio Frequency Exposure EN 62311 January 2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0Hz 300GHz) (IEC 62311:2007, modified)

More information

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS RF EXPOSURE LIMITS AND TESTING REQUIREMENTS Jay Moulton Vice President March 12, 2013 1 OVERVIEW Specific Absorption Rate (SAR) and Maximum Permissible Exposure (MPE) Standards and Limits Evaluation Methods

More information

Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL

Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL 30. 7. 1999 EN Official Journal of the European Communities L 199/59 II (Acts whose publication is not obligatory) COUNCIL COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general

More information

COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC)

COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC) COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC) THE COUNCIL OF THE EUROPEAN UNION, Having regard to

More information

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Issue 3 June 2009 Spectrum Management and Telecommunications Radio Standards Specification Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Aussi disponible

More information

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz J. Klima, R. Ščehovič Department of Physics, Faculty of Natural Sciences, University of Mathias Bel, Tajovského

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

Selected Radio Frequency Exposure Limits

Selected Radio Frequency Exposure Limits ENVIRONMENT, SAFETY & HEALTH DIVISION Chapter 50: Non-ionizing Radiation Selected Radio Frequency Exposure Limits Product ID: 94 Revision ID: 1736 Date published: 30 June 2015 Date effective: 30 June 2015

More information

Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues

Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues Technical Forum Overview and Latest Development of Standards in Human Exposure to Electromagnetic Fields (EMF) Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues Dr. Brian

More information

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT 1. SCOPE This Common Regulatory Objective, CRO, is applicable to Wireless Local Area

More information

EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT

EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT Chris Zombolas Technical Director, EMC Technologies Pty Ltd 57 Assembly Drive Tullamarine Vic. 3043,

More information

ARIB TR-T12-34.925 V3.0.0. Specific Absorption Rate (SAR) requirements and regulations in different regions

ARIB TR-T12-34.925 V3.0.0. Specific Absorption Rate (SAR) requirements and regulations in different regions ARIB TR-T12-34.925 V3.0.0 Specific Absorption Rate (SAR) requirements and regulations in different regions Refer to "Notice" in the preface of ARIB TR-T12 for Copyrights. Technical Report 3rd Generation

More information

Continuous, remote monitoring and logging of electromagnetic fields

Continuous, remote monitoring and logging of electromagnetic fields MULTI-BAND EMF AREA MONITOR AMB-8057-03/G Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total EMF values Electric field monitoring

More information

Human Exposure Limits

Human Exposure Limits Human Exposure Limits Session 3 0 Version December 2014 Learning objectives In this session we will: Learn about the international exposure limits for workers and the public Learn about methods for assessing

More information

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

TEST REPORT EN 55014-2 (1997) +A1 (2001)

TEST REPORT EN 55014-2 (1997) +A1 (2001) Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....

More information

RF safety at base station sites

RF safety at base station sites RF safety at base station sites CONTENTS 1 Purpose and scope................................................. 2 2 Introduction........................................................ 2 3 Basic information...................................................

More information

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of SKMM, 2007 FOREWORD

More information

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section EMR Exposure Limits & Assessment Methods for Mobile Phone Communications Lindsay Martin Manager, Non-Ionising Radiation Section Introduction How can we use Wireless Communication Safely? Wireless communication

More information

Human Exposure to Radiofrequency Electromagnetic Radiation

Human Exposure to Radiofrequency Electromagnetic Radiation Australia s regulator for broadcasting, the internet, radiocommunications and telecommunications www.acma.gov.au Human Exposure to Radiofrequency Electromagnetic Radiation Information for licensees of

More information

Espotel Test Laboratory Services. November 20, 2014

Espotel Test Laboratory Services. November 20, 2014 Espotel Test Laboratory Services November 20, 2014 Espotel Laboratory Services EMC, ESD, RF testing EMC chamber for radiated emissions and immunity testing Radiated interoperability for LTE, GSM/3G, WLAN

More information

ETSI EN 300 328-2 V1.1.1 (2000-07)

ETSI EN 300 328-2 V1.1.1 (2000-07) EN 300 328-2 V1.1.1 (2000-07) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission systems; data transmission

More information

ETSI TR 101 870 V1.1.1 (2001-11)

ETSI TR 101 870 V1.1.1 (2001-11) TR 101 870 V1.1.1 (2001-11) Technical Report Fixed radio transmitter sites; Exposure to non-ionising electromagnetic fields; Guidelines for working conditions 2 TR 101 870 V1.1.1 (2001-11) Reference DTR/SAFETY-00004

More information

SERVICES BROCHURE +61 8 9381 7199 +61 8 9381 7166. email: info@t-r-s.com.au www.t-r-s.com.au. PO BOX 680, Claremont, 6910, Western Australia

SERVICES BROCHURE +61 8 9381 7199 +61 8 9381 7166. email: info@t-r-s.com.au www.t-r-s.com.au. PO BOX 680, Claremont, 6910, Western Australia SERVICES BROCHURE +61 8 9381 7199 +61 8 9381 7166 email: info@t-r-s.com.au www.t-r-s.com.au PO BOX 680, Claremont, 6910, Western Australia COMPANY INFORMATION Total Radiation Solutions Pty Ltd (TRS) is

More information

AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS

AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS Annamaria PALJANOS, paljanosanna@yahoo.com Călin MUNTEANU calin.munteanu@et.utcluj.ro TECHNICAL UNIVERSITY CLUJ NAPOCA,

More information

Partial GSM TEST - REPORT

Partial GSM TEST - REPORT EUROFINS PRODUCT SERVICE GMBH Partial GSM TEST - REPORT EN 301 511 GSM/GPRS/GPS tracking unit FOX-LT-IP Test report no.: G0M20904-2307-T-51 Eurofins Product Service GmbH Storkower Str. 38c, 15526 Reichenwalde,

More information

sources in our environment i.e. Natural and man-made. The sun, earth and ionosphere are the natural source.

sources in our environment i.e. Natural and man-made. The sun, earth and ionosphere are the natural source. Electromagnetic Radiation (EMR) consist of waves of electric and magnetic energy moving together at the speed of light and sometimes is referred as electromagnetic field (EMF) They are basically two forms

More information

A Survey of Radiation Levels Associated with Mobile and Wireless Communication Technology Masts in Public Areas in Kaduna Metropolis

A Survey of Radiation Levels Associated with Mobile and Wireless Communication Technology Masts in Public Areas in Kaduna Metropolis International Journal of Emerging Engineering Research and Technology Volume 3, Issue, November 25, PP 7-2 ISSN 2349-4395 (Print) & ISSN 2349-449 (Online) A Survey of Radiation Levels Associated with Mobile

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Partial Test of: BTM411 To: EN 300 328 V1.7.1 (2006-10) Test Report Serial No: RFI/RPT1/RP76018JD01A This Test Report Is Issued Under The Authority Of Brian Watson, Operations

More information

SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012

SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012 1 (34) Report issued by an Accredited Laboratory Rapport utfärdad av ett ackrediterat laboratorium This laboratory is accredited to SS-EN ISO/IEC 17025 (SWEDAC accreditation no. 1761). SAR Test Report:

More information

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec. EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory

More information

UK Radio Licence Interface Requirement 2036 For Mobile Asset Tracking Services

UK Radio Licence Interface Requirement 2036 For Mobile Asset Tracking Services UK Radio Licence Interface Requirement 2036 For Mobile Asset Tracking Services (Version 1.0) 98/34/EC Notification Number: 2000/393/UK Published 15 December 2000 Page 1 File name: ir2036.doc Blank Page

More information

RADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01

RADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01 RADIO TEST REPORT SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range Report Reference No.... : G0M-1206-2043-TEU440G-V01 Testing Laboratory... : Eurofins Product Service GmbH Address...

More information

RWANDA UTILITIES REGULATORY AGENCY P.O BOX 7289 KIGALI,

RWANDA UTILITIES REGULATORY AGENCY P.O BOX 7289 KIGALI, REPUBLIC OF RWANDA RWANDA UTILITIES REGULATORY AGENCY P.O BOX 7289 KIGALI, Tel: +250 252 584562, Fax: +250 252 584563 Email: arms@rwanda1.com Website: www.rura.gov.rw GUIDELINES FOR LIMITING HUMAN EXPOSURE

More information

Body SAR and EU. B. Derat

Body SAR and EU. B. Derat Body SAR and EU B. Derat Overview / Outline New Approach: Directive / Standards Current applicable standard IEC/EN 62209-2:2010 Tablet case study Future of EU body SAR testing Maintenance of IEC 62209-2

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

Electromagnetic Field Safety

Electromagnetic Field Safety SAR A Basic Restriction for Electromagnetic Field Safety David Baron, PE Consulting Engineer Electromagnetic Field Safety d.baron@ieee.org NOTE. CENAM is not responsible for the content of this document.

More information

RF Exposure Evaluation Report

RF Exposure Evaluation Report RF Exposure Evaluation Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID FILING TYPE : TomTom International BV : GPS Navigation System : TomTom : 4CR51 : S4L4CR51 : Certification STANDARD : OET Bulletin

More information

EMR - SAR Testing & Approval Requirements for Australia

EMR - SAR Testing & Approval Requirements for Australia NIST Gaithersburg MD, USA 2009 SAR-EMR Requirements for Australia NIST MRA Workshop 2009 Gaithersburg, MD U.S.A. EMR - SAR Testing & Approval Requirements for Australia Chris Zombolas, Technical Director

More information

Test Report #: 1981-3 Date: April 8, 2005

Test Report #: 1981-3 Date: April 8, 2005 Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model

More information

EMC Test for Compliance with EU EMC Directive 2004/108/EU

EMC Test for Compliance with EU EMC Directive 2004/108/EU EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods

More information

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20 EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan

More information

TECHNICAL SPECIFICATION FOR BROADBAND WIRELESS ACCESS (BWA) EQUIPMENT

TECHNICAL SPECIFICATION FOR BROADBAND WIRELESS ACCESS (BWA) EQUIPMENT TECHNICAL SPECIFICATION FOR BROADBAND WIRELESS ACCESS (BWA) EQUIPMENT Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of

More information

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements Jagadish Nadakuduti, Lin Lu, Paul Guckian Qualcomm Technologies,

More information

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz International Electrotechnical Commission IEC TC106 Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz R. C. Petersen Chairman Secretariat and

More information

Non-ionizing electromagnetic radiation monitoring in Greece

Non-ionizing electromagnetic radiation monitoring in Greece Non-ionizing electromagnetic radiation monitoring in Greece Antonis Gotsis, Nikolaos Papanikolaou, Dimitris Komnakos, Agamenon Yalofas, and Dr Philip Constantinou Mobile Radio-Communications Laboratory,

More information

IEC and CISPR Standards

IEC and CISPR Standards IEC and CISPR Standards With thanks to Gideon Wiid, PhD student, and Paul van der Merwe EE Eng, 2 May, 2007 EMC Definition: Electromagnetic compatibility itself is defined as [1]: "the ability of an equipment

More information

ETSI EN 300 328-1 V1.2.2 (2000-07)

ETSI EN 300 328-1 V1.2.2 (2000-07) EN 300 328-1 V1.2.2 (2000-07) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission systems; data transmission equipment operating

More information

EMR-300 Broadband RF Survey Meter

EMR-300 Broadband RF Survey Meter Electric d Magnetic Field Measurement EMR-300 Broadbd RF Survey Meter Available with Isotropic Probes to cover 3 khz to 60 GHz Easy-to-Use Design Lightweight d Rugged Cost Effective Fully Automatic Zeroing

More information

MEASUREMENT AND ANALYSIS OF RF EME LEVELS FROM MOBILE TELEPHONE BASE STATIONS LOCATED AT LEICHHARDT, NSW

MEASUREMENT AND ANALYSIS OF RF EME LEVELS FROM MOBILE TELEPHONE BASE STATIONS LOCATED AT LEICHHARDT, NSW AUSTRALIAN RADIATION PROTECTION AND NUCLEAR SAFETY AGENCY A R P N S A Lower Plenty Road YALLAMBIE VIC 3085 Phone 61 3 9433 2211 Fax 61 3 9432 1835 E-mail: arpansa@health.gov.au Web: www.arpansa.gov.au

More information

Electromagnetic Radiation (EMR) Testing Report Twenty-Five Schools, Peel District School Board

Electromagnetic Radiation (EMR) Testing Report Twenty-Five Schools, Peel District School Board Report Twenty-Five Schools, Peel District School Board G2S13600 Peel District School Board 5650 Hurontario Street Mississauga, Ontario L5R 1C6 26/05/2014 Executive Summary G2S Environmental Consulting

More information

Human exposure to RF

Human exposure to RF INTERNATIONAL ELECTROTECHNICAL COMMISSION Human exposure to RF Don Heirman ACEC/TC106 Liaison Representative APEMC symposium May 2015 Copyright IEC, Geneva, Switzerland TC106 Scope To prepare international

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

HERMES: Human Exposure and Radiation Monitoring of Electromagnetic Sources. www.hermes-program.gr

HERMES: Human Exposure and Radiation Monitoring of Electromagnetic Sources. www.hermes-program.gr HERMES Program: The Greek Experience of an Electromagnetic Radiation Monitoring System A. Manassas, A. Boursianis, T. Samaras and J. N. Sahalos HERMES: Human Exposure and Radiation Monitoring of Electromagnetic

More information

Electromagnetic Compatibility Test Report Test results of Floww equipment

Electromagnetic Compatibility Test Report Test results of Floww equipment Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww

More information

EMR EMISSIONS FROM REMOTE AREA POWER SUPPLY EQUIPMENT

EMR EMISSIONS FROM REMOTE AREA POWER SUPPLY EQUIPMENT Radiation Protection in Australasia Vol. 22, No. 2 Refereed Paper EMR EMISSIONS FROM REMOTE AREA POWER SUPPLY EQUIPMENT Phillip Knipe and Philip Jennings Physics and Energy Studies, Murdoch University,

More information

Dual Chamber Temporary External Pacemaker

Dual Chamber Temporary External Pacemaker 5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

Application Note AN-00126

Application Note AN-00126 Considerations for Operation within the 902-928MHz Band Application Note AN-00126 Introduction This application note is designed to give the reader a basic understanding of the legal and technical considerations

More information

RX-AM4SF Receiver. Pin-out. Connections

RX-AM4SF Receiver. Pin-out. Connections RX-AM4SF Receiver The super-heterodyne receiver RX-AM4SF can provide a RSSI output indicating the amplitude of the received signal: this output can be used to create a field-strength meter capable to indicate

More information

Why test results can t compare

Why test results can t compare Automotive RF immunity test set-up analysis Why test results can t compare Mart Coenen, EMCMCC, Eindhoven, the Netherlands Hugo Pues, Melexis Technologies NV, Tessenderlo, Belgium Thierry Bousquet, Continental,

More information

FCC RF Exposure Report

FCC RF Exposure Report FCC RF Exposure Report FCC ID Equipment Model No. Brand Name Applicant : SQGBT900 : Bluetooth Dual Mode UART AT featuring smartbasic : BT900-SA, BT900-SC (please refer to 1.1.1 for more details.) : Laird

More information

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual Field Analyzer FA106 and FA306 Users Manual 1 Contents Contents...2 Preface...3 Chapter 1 Basic Functions...4 1.1 Turning on/off...4 1.2 Choosing the required measuring mode...4 1.3 Picture of front panel...5

More information

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz Test & Measurement Data Sheet 02.00 R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz R&S R-Line Compact Test Chamber At a glance The R-Line

More information

Draft ETSI EN 301 783-1 V1.2.1 (2009-07)

Draft ETSI EN 301 783-1 V1.2.1 (2009-07) Draft EN 301 783-1 V1.2.1 (2009-07) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Commercially available amateur radio

More information

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0. Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15

More information

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers

More information

Continuous, remote monitoring and logging of electromagnetic fields

Continuous, remote monitoring and logging of electromagnetic fields MULTI-BAND EMF AREA MONITOR AMB-8057 Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total emf values Magnetic fields monitoring from

More information

Radio waves and health. Mobile communications

Radio waves and health. Mobile communications Radio waves and health Mobile communications Mobile communications and health Mobile telephony Radio communications have been used for more than a hundred years in various sorts of applications. Already

More information

NI USB-5681 RF Power Meter Specifications

NI USB-5681 RF Power Meter Specifications NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour

More information

EMC TEST REPORT For. Webcam. Model Number: CAM67U

EMC TEST REPORT For. Webcam. Model Number: CAM67U EMC TEST REPORT For Webcam Model Number: CAM67U Prepared for : Gembird Europe B.V. Wittevrouwen 56, 1358CD Almere, The Netherlands. Phone: +31-36-5211588 Prepared By : Shenzhen Meihua Electronic Technology

More information

Measuring electric and magnetic fields

Measuring electric and magnetic fields NARDA BROADBAND FIELD METER NBM-520 Measuring electric and magnetic fields ranging from high frequency to microwaves Non-directional measurement using isotropic probes for applications in the frequency

More information

Contents. 2 NP560-NP562 Installation Guide YML821 Rev1

Contents. 2 NP560-NP562 Installation Guide YML821 Rev1 Contents Introduction...4 Package Contents...5 Installing the NetComm Indoor Wireless Booster (NP560/NP562)...6 Electrical Specification...8 Appendix A: Registration and Warranty Information...9 2 NP560-NP562

More information

EMFs Exposure Monitoring and SAR Certification in Telecom Italia

EMFs Exposure Monitoring and SAR Certification in Telecom Italia GRUPPO TELECOM ITALIA ITU Workshop on Human Exposure to Electromagnetic Fields (EMFs) Turin, Italy, 9 May 2013 EMFs Exposure Monitoring and SAR Certification in Telecom Italia Mauro Francavilla Paolo Gianola

More information

VARIATION TO LICENCE AREA PLAN

VARIATION TO LICENCE AREA PLAN Attachment A VARIATION TO LICENCE AREA PLAN BRIDGETOWN (RADIO) May 2001 LICENCE AREA PLAN BRIDGETOWN VARIATION The Australian Broadcasting Authority hereby varies the licence area plan (LAP) for radio

More information

The tradescantia micronucleus bioassay:

The tradescantia micronucleus bioassay: Investigation of the mutagenicity of electromagnetic fields using the tradescantia micronucleus bioassay H. Lehmann 1, C. Pickl 2, M. Urech 3 1 Environment & Electromagnetic Compatibility, Swisscom Innovations,

More information

For many years the general public

For many years the general public David Seabury, ETS-Lindgren An Update On SAR Standards And The Basic Requirements For SAR Assessment For many years the general public has been concerned about the possible health effects of exposure to

More information

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Telstra Pre-Paid 3G Wi-Fi. This guide will help you get connected as quickly and

More information

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless) 1 2 The range of RF spans 3 KHz (3000 Hz) to 300 GHz (300 million Hz) Frequencies of RF devices range from the low frequency AM broadcasts (80 MHz) to higher frequency mobile phones (1900 MHz) smart meters

More information

National Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields

National Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields November 2009 Contents 1 PRELIMINARY AND GENERAL... 5 1.1 CITATION... 5 1.2 ORIGIN AND STATUS OF THE NATIONAL GUIDELINES... 5 1.3 PURPOSE... 5 1.4 SCOPE AND APPLICATION... 6 1.5 TERMS AND DEFINITIONS...

More information

ARCHOS (www.archos.com/support).

ARCHOS (www.archos.com/support). 1 ! www.archos.com/register, ARCHOS.. ARCHOS, (www.archos.com/register).. ARCHOS (www.archos.com/support)., Windows, Windows Help Start ( ), Help and Support.. ARCHOS. 2 ,.! /, : ARCHOS 9,,,,,. -.,. ARCHOS

More information

EMC Standards: Standards of good EMC engineering

EMC Standards: Standards of good EMC engineering Electromagnetic Compatibility (EMC) IEEE Definition Origin, control, and measurement of electromagnetic effects on electronic and biologic systems. IEEE EMC Society Areas of Interest EMC Standards: Standards

More information

Measurements of radiofrequency fields from a WEL Networks Smart Meter

Measurements of radiofrequency fields from a WEL Networks Smart Meter Measurements of radiofrequency fields from a WEL Networks Smart Meter Report 2012/36 This report was prepared for: WEL Networks Ltd P O Box 925 Hamilton Report prepared by: Martin Gledhill Finalised: 7

More information

OpenWay Radio Frequency FAQ

OpenWay Radio Frequency FAQ OpenWay Radio Frequency FAQ March 10, 2010 2010, Itron Inc. All rights reserved. 1 Overview This document provides general information about radiofrequency (RF) electromagnetic fields from OpenWay wireless

More information

Mobile use, radio signals and health

Mobile use, radio signals and health Mobile use, radio signals and health Mobile use, radio signals and health How does the mobile network work? Since the 1970s, the use of various types of radio transmitters has risen dramatically, to the

More information

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP-235864 DSL-20WA 420024 1 Revision: A Date: 2011.10.24 FOR AC-DC LED DRIVER MODEL NO.

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP-235864 DSL-20WA 420024 1 Revision: A Date: 2011.10.24 FOR AC-DC LED DRIVER MODEL NO. CUSTOMER: PART NUMBER: A200 APPROVAL SHEET FOR AC-DC LED DRIVER MODEL NO. DSL-20WA 420024 1 ORDER NO: SP-235864 承 認 書 确 認 后 請 簽 回 一 份 CUSTOMER APPROVED SIGNATURE DEE VAN ENTERPRISE CO., LTD (Head-Quarter)

More information

Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets

Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets Ministry of Environmental Protection Ministry of Communications Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets Based on author s PhD thesis/book- An analysis of regulatory

More information

English version. Central Secretariat: rue de Stassart 35, B - 1050 Brussels

English version. Central Secretariat: rue de Stassart 35, B - 1050 Brussels Annex 1 EN 50445 EUROPEAN STANDARD EN 50445 NORME EUROPÉENNE EUROPÄISCHE NORM February 2008 ICS 17.220.01; 25.160.10 English version Product family standard to demonstrate compliance of equipment for resistance

More information

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry

More information

BASIS for August 1996 REGULATION

BASIS for August 1996 REGULATION DRAFT TECHNICAL pr TBR 029 BASIS for August 1996 REGULATION Source: ETSI TC-SES Reference: DTBR/SES-00007 ICS: 33.060.30 Key words: broadcasting, earth station, radio, satellite, TV, TVRO, type approval

More information

Wireless Power Transfer

Wireless Power Transfer Francesco Carobolante Vice President Engineering Wireless Power Transfer Overcoming the Technological Hurdles DISCLAIMER: The information provided in this presentation is for informational purposes only

More information

CE Test Report. : Microchip Technology Inc. 2355 West Chandler Blvd., Chandler, Arizona 85224-6199, USA

CE Test Report. : Microchip Technology Inc. 2355 West Chandler Blvd., Chandler, Arizona 85224-6199, USA CE Test Report Equipment : IEEE 802.11b/g Wireless LAN module Brand Name : MICROCHIP Model No. : MRF24WG0MA/MB Standard : EN 300 328 V1.8.1 (2012-06) Operating Band : 2400 MHz 2483.5 MHz Applicant Manufacturer

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

TECHNICAL SPECIFICATION FOR CORDLESS TELEPHONE SYSTEMS

TECHNICAL SPECIFICATION FOR CORDLESS TELEPHONE SYSTEMS TECHNICAL SPECIFICATION FOR CORDLESS TELEPHONE SYSTEMS Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of SKMM, 2007 FOREWORD

More information

EN 50360:2001+A1:2012 SAR EVALUATION REPORT. Baoji Jiayuyutong electronic co.,ltd

EN 50360:2001+A1:2012 SAR EVALUATION REPORT. Baoji Jiayuyutong electronic co.,ltd EN 50360:2001+A1:2012 SAR EVALUATION REPORT For Baoji Jiayuyutong electronic co.,ltd Building A, 28# Longteng Street, Jianyi Village, Henggang Town, Longgang District, Shenzhen, P. R. China Model: JY-S3

More information

IJMIE Volume 2, Issue 5 ISSN: 2249-0558

IJMIE Volume 2, Issue 5 ISSN: 2249-0558 AN OPTIMAL DETECTION TECHNIQUE FOR MOBILE RADIO FREQENCIES M.SUCHARITHA* T.JAHNAVI* N.POORNIMA* P.KRISHNA SILPHA* K MURALI** ABSTRACT: Cellular phone technology is rapidly changing. Features like Bluetooth,

More information

The Salzburg Model: A Precautionary Strategy for Siting of Base Stations

The Salzburg Model: A Precautionary Strategy for Siting of Base Stations The Salzburg Model: A Precautionary Strategy for Siting of Base Stations Dr. Gerd Oberfeld, Dr. Christoph König Federal State of Salzburg, Public Health Department, Environmental Health P.O. Box 527, A-5010

More information