INSTALLATION AND OPERATING MANUAL ITYS
|
|
- Loraine Beasley
- 7 years ago
- Views:
Transcription
1 INSTALLATION AND OPERATING MANUAL IOMITYTWXX00-GB_
2 Thank you for choosing, a SOCOMEC UPS product. You have purchased a high professional UPS to provide you protection against black-outs and electrical impurities. The range has been designed specifically for the protection of critical electronics and I.T. consumers such as servers, UNIX workstations or networking peripherals which could suffer hardware damage and data losses as a result of the disturbance deriving from the electrical mains. For correct use and to obtain the best performance from this product, please read and follow carefully the instructions contained within. Keep this manual at hand for rapid and easy consultation. ITALIANO Reproduction of any part of this manual is forbidden without the manufacturer s consent. The information and drawings contained herein may be changed without prior notice and are not binding upon the manufacturer. SOCOMEC UPS retains the full and exclusive ownership rights over this document. Only a personal right to utilize the document for the application indicated by SOCOMEC UPS is granted to the recipient of such document. All reproduction, modification, dissemination of this document whether in part or whole and by any manner are expressly prohibited except upon Socomec s express prior written consent. This document is not a specification. SOCOMEC UPS reserves the right to make any changes to data without prior notice. 2 IOMITYTWXX00-GB_00
3 INDEX 1. CERTIFICATE AND CONDITIONS OF WARRANTY SAFETY STANDARDS GENERAL DESCRIPTION Operation UNPACKING AND INSTALLATION Environmental requirements for installation Unpacking of the UPS kva, 2 kva, 3 kva kva, 10 kva FRONT VIEW REAR VIEW CONNECTIONS EXTERNAL BATTERY CABINET CONNECTION (for LB models only) Important External battery cabinet connection Modular battery cabinet Battery cabinet specific for Itys MIMIC PANEL MODES OF OPERATION Battery recharging Start-up and shutdown 1 kva, 2 kva, 3 kva Start-up with mains present Start-up without mains present Shutdown with mains present Shutdown without mains present Start-up and shutdown 6 kva, 10 kva Start-up with mains present Start-up without mains present Shutdown with mains present Shutdown without mains present Operation with manual by-pass ( 6 kva, 10 kva only) Operation from manual by-pass to normal operation ( 6 kva, 10 kva only) Battery test VISUAL AND ACOUSTIC SEGNALISATIONS COMMUNICATION Communication solutions RS232 interface NetVision card Use of signalling rrelay interface MAINTENANCE Troubleshooting for minor problems TECHNICAL SPECIFICATIONS IOMITYTWXX00-GB_00 3
4 ITALIANO
5 1 CERTIFICATE AND CONDITIONS OF WARRANTY This SOCOMEC UPS uninterruptible power system is guaranteed against manufacturing and material defects, for a period of 12 months from the date of purchase (local warranty condition apply in addition to the general one). This certificate of warranty must NOT be sent back, but must be kept by the customer together with the purchase receipt, to be used if the product should require interventions while under warranty. The period of validity of the warranty is calculated from the date of purchase of the new product, by the final user, from an official reseller (the date shown on the purchase receipt is used as proof). The warranty is of the carry-in type: free supply of parts and labour for repairs, with return of a product to be replaced to SOCOMEC UPS, or authorized centres, at the customer s cost and risk. In order to use the warranty service, the user must respect the following rules: packaging other than the original is not covered by the warranty; of purchase and the information necessary to identify the product (model, serial number). The number of the authorization for return for repairs must also be attached, with a detailed description of the defect found in the product. If any of these elements is missing, the warranty is invalid. The return authorization number is issued by the service centres by telephone on receiving notification of the malfunction; calculate expiry of the warranty, which may lead to a reduction in the product s warranty period. The product is not covered by warranty for damage caused by negligence (use outside the tolerance ranges: electric power supply, lightning, humidity, temperature, bad ventilation, etc.), tampering or any unauthorized intervention. During the warranty period, SOCOMEC UPS may, at its discretion, decide to repair the product or replace the defective parts with new parts or with used parts that are equivalent to new parts in terms of functions and performance. In the case of the battery, the warranty is valid if periodic recharging has been effected within the terms indicated on the packaging. It is advisable, therefore, after purchase, to check that the date of the next recharging has not passed. Optionals. Warranty for the optionals is 12 months and is of the carry-in type. IOMITYTWXX00-GB_00 5
6 CERTIFICATE AND CONDITIONS 1 OF WARRANTY Software products. Warranty for the software is 90 days. The software is guaranteed to function in compliance with the manual and the written material accompanying the product. Hardware accessories or supports (e.g. disks, cables, etc.) attached are guaranteed from material and manufacturing defects under normal use and service, for a period of 12 months from the date of purchase. ITALIANO Under no circumstances will SOCOMEC UPS be responsible for damages (including, without limitations, damage for loss of earnings, interruption of activity, loss of data or other economic losses) deriving from the use of this product. The present conditions are subject to Italian law. All disputes to be heard by the Court of Vicenza. 6 IOMITYTWXX00-GB_00
7 2 SAFETY STANDARDS This manual must be kept in the vicinity of the UPS, so that the operator may consult it at any time for clarifications on the correct use of the UPS. Read the manual carefully before connecting the unit to the general mains power supply and to the devices to be powered. Before putting the UPS (Uninterruptible Power Supply) into operation, the operator must be fully aware of the functions and positions of all the controls and of the technical and functional characteristics of the system, in order to avoid risks to persons and to the equipment. electrical installation must be effected EXCLUSIVELY by qualified personnel, scrupulously following the instructions contained in this manual. Before starting, the unit must be provided with an equipotential connection as established by the safety standards in force. The earth cable of the UPS is to be connected to an efficient earthing point. If the earth connection is not made, all devices connected to the UPS will be without equipotential connection. In this case the manufacturer declines all responsibility for damage or accidents caused by nonobservance of the said standard. In case of mains failure (battery mode), do not disconnect the input cable from mains so to ensure the earth connection to the loads supplied. All subsequent maintenance operations must be carried out solely and exclusively by authorised personnel. Inside the system high electric voltages are generated which may endanger maintenance personnel who are not sufficiently prepared and trained for such tasks. If at any time during use a hazard condition is created, remove the mains power supply (if possible through the distribution panel upstream of the unit) and switch the UPS off completely following the appropriate procedure. The UPS contains an internal power source that is the batteries. The UPS output may be powered even when the UPS is not connected to the mains power supply. Do not force, break or try to open the batteries. They are sealed and do not require any maintenance. Inside they contain substances that are toxic to health and that pollute the atmosphere. Do not switch the UPS on if there is any leak of liquid, or if a residual white powder is noted. Avoid contact of the UPS unit with water or liquids in general. Do not introduce foreign bodies. If the unit needs to be scrapped, it is essential to entrust the equipment solely and exclusively to specialist disposal companies. These are obliged to break up and dispose of the various components in accordance with the legal provisions in force nationally. Only for kva: as the mains cable of the UPS is considered a disconnecting device, the mains socket to which the UPS is connected and/or the rear of the UPS must be accessible and easy to disconnect. Only for kva: the UPS generates a leakage current of approximately 3 ma. In order to guarantee the maximum limit on leakage current of 3.5 ma, ensure that the load has a maximum leakage current of 2 ma. If the load leakage current exceeds this limit, qualified personnel should connect the UPS to an industrial-type mains power supply, compliant with IEC 309, dimensioned for a current that is appropriate for the system s power rating. IOMITYTWXX00-GB_00 7
8 2 SAFETY STANDARDS particular critical applications such as life support systems, medical applications, commercial transportation, nuclear facilities or any other application or systems where product failure is likely to cause substantial harms to person or property, the products may have to be adapted. For such uses we would advise you to contact SOCOMEC UPS beforehand to confirm the ability of these products to meet the requested level of safety, performance, reliability and compliance with applicable laws, regulations and specifications. ITALIANO Only for kva: in order to comply with the requirements for emergency shutdown (ESD), a relay card with remote ESD function is available. Should the card not be present, the output line must be equipped with a disconnecting switch to interrupt the continuous power supply to the load in any operation mode of the UPS. Only for 6-10 kva: If the UPS does not have an automatic protection device against current back-feed, the operator/installer must: - add warning labels to all the mains power disconnecting switches installed at a distance from the UPS area; this serves to remind technicians of the fact that the circuit is connected to a UPS. - install an external isolating device as shown in figure L N Q ISOLATE THE UPS BEFORE OPERATING ON THIS CIRCUIT External distribution panel. T UPS. L N B Legend. B Coil. Q Magneto-thermal input main switch. T 90 A AC1 remote contactor 2-pole; 230 V coil. 8 IOMITYTWXX00-GB_00
9 3 GENERAL DESCRIPTION The main purpose of the UPS is to protect sensitive and critical equipment items from the electrical disturbances that can compromise operation. Black-outs, brown-outs, variations of voltage and frequency, lightning, electrostatic discharges and rapid overvoltages are phenomena found in all office and industrial environments and which cause hardware damage and data losses. 3.1 OPERATION. is based on the on-line, double conversion, VFI (Voltage and Frequency Independent) technology to guarantee the highest level of electrical protection. With this principle of operation, the voltage and the frequency at the input of the UPS are completely regenerated via a first AC/DC conversion followed by a DC/AC conversion in order to provide the consumer a stable waveform that is exempt of noise or distortions, and therefore completely independent of the input mains. In this double conversion process, the UPS also becomes a filter element in relation to the electrical network thus preventing the distorting absorption (typical of IT users) from being reflected on the power supply line. In the event of a black-out, provides for generation of the output voltage without any disturbance, even transient, drawing the power from the internal batteries. During normal operation with the mains line present, recharges the batteries fully automatically and independently Wiring diagram. I Legend. A UPS. B Mains input. C Power output for consumer lines. D AC/DC rectifier. E DC/AC inverter. F Automatic internal by-pass. G Battery-charger. H Batteries. I Manual by-pass (6 kva and 10 kva only). B D E F G H A C IOMITYTWXX00-GB_00 9
10 4 UNPACKING AND INSTALLATION ITALIANO 4.1 ENVIRONMENTAL REQUIREMENTS FOR INSTALLATION. Install the UPS after first checking the following: to direct sunlight. data can be found on the data plate. serial interface. CAUTION IF DAMAGED. BATTERIES, NON SPILLABLE. Packages, crushed, punctured, or torn such that contents are revealed must be set aside in an isolated area and inspected by a qualified person. If the package is deemed to be not shippable, the contents must be promptly collected, segregated, and either the consignor or consignee contacted. 10 IOMITYTWXX00-GB_00
11 4 UNPACKING AND INSTALLATION 4.2 UNPACKAGING OF THE UPS kva, 2 kva, 3 kva kva, 10 kva IOMITYTWXX00-GB_00 11
12 5 FRONT VIEW Mimic panel. ITALIANO OFF button ON button and silence buzzer 6 kva 10 kva 2 kva 3 kva 1 kva 12 IOMITYTWXX00-GB_00
13 6 REAR VIEW A F I A B F I B G C G C D D E E 1 kva 2 kva A F I B G Legend. A RS232 serial port (JBUS protocol) B Fan D C Input protection D ADSL/modem/telephone line protection C E H E Input socket (IEC 320) F Slot for optional communication boards G Output sockets (IEC 320) 3 kva H Output terminals I Output socket for external battery cabinet connection (LB models only) IOMITYTWXX00-GB_00 13
14 6 REAR VIEW Legend. A F A B RS232 serial port (JBUS protocol) Fan B1 Fan (10 kva only) ITALIANO B C D E F Input protection (magneto-thermal) Input and output terminal board Cable couplings Slot for optional communication boards B1 G Manual by-pass H Wheels with safety locking system I I Output socket for external battery cabinet connection (LB models only) C G D E H H 6 kva 10 kva 14 IOMITYTWXX00-GB_00
15 7 CONNECTIONS Connection to the mains supply and the load should be effected by using cables of an appropriate thickness and which conform to the standards in force. A distribution panel must be set up (if there is not one already) which can be used to isolate the mains upstream of the UPS. This panel must have an automatic switch of sufficient capacity for the current absorbed at full load and a differential breaking device. OUT 230 V~ 6 x IEC320 OUT 230 V~ 4 x IEC320 IN 230 V~ 1 kva IN 230 V~ 2 kva Use the server s supply cord (IEC 320). Use the server s supply cord (IEC 320). OUT 230 V~ 4 x IEC320 3 kva IN 230 V~ Use power cord provided (IEC A). IN 230 V~ Use the power cord provided (IEC A). 3 kva OUT 230 V~ 3 x 2,5 mm 2 IOMITYTWXX00-GB_00 15
16 7 CONNECTIONS The installation and the system must comply with national plant regulations. If a differential switch is installed on the mains power switch (optional), it must be inserted upstream from the distribution panel. Mains UPS Output ITALIANO CAUTION! Use selective type differentials. Any current dispersed by the loads will be summed to that of the UPS. The differential protection must be regulated in cases of loads with high current dispersion. Ø (mm 2 ) 6 10 UPS 6 kva 10 kva Ø (mm 2 ) N L JP1 JP2 L N N L JP1 JP2 L N INPUT OUTPUT 6 kva 10 kva IOMITYTWXX00-GB_00
17 8 EXTERNAL BATTERY CABINET CONNECTION (for LB models only) 8.1 IMPORTANT. WARNING! Danger of explosion if the batteries are replaced with others of the wrong type. exclusively to specialist disposal companies. As provided for by the local laws in force, batteries must not be disposed of with other industrial or domestic waste. WARNING! It is very dangerous to touch any part of the batteries as there is no isolation between the batteries and the mains power source. 8.2 EXTERNAL BATTERY CABINET CONNECTION. WARNING! Before carrying out any operation, ensure that: Use the cable supplied with the unit to connect the UPS to the Battery cabinet. Cabling errors with inversion of the battery polarity may cause permanent damage to the equipment. If using cabinets not supplied by the manufacturers of the UPS, it is the installer s responsibility to check the electrical compatibility and the presence of appropriate protection devices between the UPS and the battery cabinet (fuses and switches of sufficient capacity to protect the cables from the UPS to the battery cabinet). IOMITYTWXX00-GB_00 17
18 8 EXTERNAL BATTERY CABINET CONNECTION (for LB models only) 8.3 MODULAR BATTERY CABINET kva ITALIANO 2-3 kva 8.4 BATTERY CABINET SPECIFIC FOR kva 6-10 kva IOMITYTWXX00-GB_00
19 9 MIMIC PANEL The mimic panel located on the front of the UPS provides all the information relating to the unit s operating status. Legend. A B A B Yellow LED. By-pass mode. Yellow LED. Power supply from battery (battery mode). C D E Green LED. Inverter mode (continuity). Red LED. General alarm (fault or failure). ON button and silence buzzer. H C D F LED bar. Depending on the situation, this shows the charge level (figure 9.1-1) or the battery capacity (figure 9.1-2). G OFF button. H Green LED. Mains present. G F E Indication of load level Indication of battery capacity. 0 35% 0 20% 36 55% 56 75% 76 95% % 21 40% 41 60% 61 80% % LED ON LED OFF IOMITYTWXX00-GB_00 19
20 10 MODES OF OPERATION 10.1 BATTERY RECHARGING. Connect the UPS to the mains voltage for approx. 8 hours to recharge the internal batteries. The UPS can also be used with batteries that are not fully charged, but back-up time will be reduced if there is a mains power failure. ITALIANO 10.2 START-UP AND SHUTDOWN 1 kva, 2 kva, 3 kva Start-up with mains present Normal operation. > 1 sec TEST Start-up all the loads, one at a time Start-up without mains present Operation on battery mode. > 1 sec TEST Start-up all the loads, one at a time. 20 IOMITYTWXX00-GB_00
21 10 MODES OF OPERATION Shutdown with mains present > 1 sec the other. supply for full shutdown Shutdown without mains present > 1 sec TEST Turn off all the loads, one after the other. IOMITYTWXX00-GB_00 21
22 10 MODES OF OPERATION 10.3 START-UP AND SHUTDOWN 6 kva, 10 kva Start-up with mains present ITALIANO ON TEST > 1 sec Normal operation. TEST Start-up all the loads, one at a time Start-up without mains present Operation on battery mode. > 1 sec TEST Start-up all the loads, one at a time. 22 IOMITYTWXX00-GB_00
23 10 MODES OF OPERATION Shutdown with mains present > 1 sec TEST OFF TEST Remove the mains power supply for full shutdown. IOMITYTWXX00-GB_00 23
24 10 MODES OF OPERATION Shutdown without mains present ITALIANO > 1 sec TEST Turn off all the loads, one after the other OPERATION WITH MANUAL BY-PASS ( 6 kva, 10 kva only). If the maintenance bypass is activated using the appropriate procedure, the load is powered directly from the maintenance by-pass, while the UPS is separated from the power supply. WARNING! In this mode continuity is not guaranteed in the event of a mains power failure. This operating mode can be selected for maintenance to be carried out on the system so that the necessary actions can be performed by service personnel without having to disconnect the power supply to the load IOMITYTWXX00-GB_00
25 10 MODES OF OPERATION 10.5 OPERATION FROM MANUAL BY-PASS TO NORMAL OPERATION ( 6 kva, 10 kva only) BATTERY TEST. The battery test can be activated manually or via the SW (as long as the conditions are right). The automatic test checks the efficiency of the batteries so that, if necessary, the user can be informed when they need to be replaced in order to guarantee sure service of the UPS. If the test fails, a specific alarm condition is displayed. For a manual test, press the button for more than 3 seconds (with the UPS in normal conditions); the test lasts for about 10 seconds with the LED flashing to indicate that the test is in progress. It is advisable to perform the test with batteries fully charged. IOMITYTWXX00-GB_00 25
26 11 VISUAL AND ACOUSTIC SEGNALISATIONS LED ON LED OFF LED flashing Indication of load level (normal operation). 0 35% ITALIANO 36 55% 56 75% 76 95% % Indication of battery capacity (operation on battery mode). 0 20% 21 40% 41 60% 61 80% % every second every 4 seconds every 4 seconds every 4 seconds every 4 seconds Bypass mode. Other optical signals that may be present are due to other reasons. every 2 minutes Overload in operation from mains with UPS in Inverter mode every second Overload in operation from mains with UPS in By-pass mode every second Irregular mains voltage. Other acoustic and/or optical signals that may be present are due to other reasons Overload in operation on battery mode, first report signal. Other optical signals that may be present are due to other reasons. every second Overload in operation on battery mode, load blocked. Other optical signals that may be present are due to other reasons. continuous 26 IOMITYTWXX00-GB_00
27 11 VISUAL AND ACOUSTIC SEGNALISATIONS LED ON LED OFF LED flashing Very high temperature. Other optical signals that may be present are due to other reasons. continuous Irregular inverter operation. Other optical signals that may be present are due to other reasons. continuous Output short-circuit. Other optical signals that may be present are due to other reasons. continuous Irregular BUS voltage. Other optical signals that may be present are due to other reasons. continuous Battery charger and battery faulty. Other optical signals that may be present are due to other reasons. every second BAT SCR faulty. Other optical signals that may be present are due to other reasons. continuous Irregular fan operation. Other optical signals that may be present are due to other reasons. every second INV RLY faulty. Other optical signals that may be present are due to other reasons. continuous Irregular communication. Other optical signals that may be present are due to other reasons. continuous IOMITYTWXX00-GB_00 27
28 12 COMMUNICATION Communication software and accessories to enable the device status to be monitored are available to optimize UPS operation and for the correct management of shutdown due to end of back-up time. The applications allow all mains power failures and any battery depletion to be recorded in order to be able to activate an orderly automatic procedure to close programs and shut down the system. The UPSs come with RS232 serial communication interfaces and slots for the NetVision card. ITALIANO 12.1 COMMUNICATION SOLUTIONS. Uni Vision local management software (RS232 interface) for local shutdown of Windows & Linux systems. Free on (CD included in some models). Uni Vision Pro network management software (RS232 interface) for local and remote shutdown: supports the major operating systems through Java Shutdown Client technology. NetVision Web/SNMP manager (Web/SNMP card) for UPS control over LAN with TCP/IP protocol. Allows remote shutdown through Java Shutdown Client technology. BMS (JBUS protocol): possibility to integrate the UPS with BMS (Building Management Systems). BAUD RATE SERIAL LINK: Baud Rate parameter setting (see the operating manual of the software): - UniVision: Menu: SW Setup 4 Communication 4 RS232 Speed set the Baud Rate value 4 - UniVision Pro: File: Univision.cfg 4 ProtocolSpeed = Baud Rate set the Baud Rate value 4 - NetVision: Page: Mgm MENU 4 Configuration 4 Baudrate (bps) set the Baud Rate value 4-1 kva: 9600 b/s - 2 kva: 9600 b/s - 3 kva: 9600 b/s - 6 kva: 2400 b/s - 10 kva: 2400 b/s 28 IOMITYTWXX00-GB_00
29 12 COMMUNICATION 12.2 RS232 INTERFACE. Communication with the server can take place directly via the RS232 interface. In addition to local or networked shutdown it is possible to perform full monitoring of the electrical parameters regarding battery status and the automatic programming of the UPS start-up and shutdown procedures. For a complete description of the software features, refer to the UniVision and UniVision Pro documentation NETVISION CARD. NetVision permits direct connection of the UPS to a LAN (RJ45 Ethernet) and remote control of the UPS through TCP/IP using a WEB browser. For a complete description, refer to the Net Vision documentation USE OF SIGNALLING RELAY INTERFACE. Optional card (available for insertion in the slot) which is able to handle 5 isolated contact signals to remote relay UPS status information. The maximum voltage that can be applied to the contacts is 24 Vdc and the maximum current is 500 ma Internal fault General alarm 6 By-pass mode Legend - pin DB9 1 Internal fault 2 General alarm 3 Return for ESD 4 Positive for ESD 5 Relay common 6 Operation from by-pass 7 Batteria almost out 8 Operation from inverter 9 Mains missing 5 Relay common 7 Batteria almost out 8 Inverter mode 9 Mains missing Where required, it is also possible to switch off the UPS via a remote external contact. The command is received by leaving the contact closed for 3 consecutive seconds. The external contact must be closed between pin 3 and pin 4 (figure ). The external contact MUST be dedicated not respected, permanent damage may be caused to the UPS ESD IOMITYTWXX00-GB_00 29
30 13 MAINTENANCE WARNING! DANGEROUS electrical voltages are generated inside the UPS. All maintenance operations to be performed SOLELY AND EXCLUSIVELY by authorized personnel. ITALIANO correct maintenance of the battery charge. before switching the UPS off completely (mains present for eight hours consecutively) TROUBLESHOOTING FOR MINOR PROBLEMS. IMPORTANT! If after following the indications in this chapter, the problems persist or are repeated frequently, you should call the technical service centre providing a full description of the problem. Troubleshooting for minor problems Problem Possible cause Solution The MAINS LED does not come on, the acoustic alarm sounds at intervals. ALARM LED on and fault signal active. Battery back-up time less than indicated. Overload LED indicator lit. No communication between UPS and PC Overtemperature signalisation The main switch is not inserted. Mains voltage is missing. Input protection device triggered. UPS broken. The batteries are not fully charged. The batteries are faulty. The battery-charger is defective. Overload on the UPS output. Serial connection cable error. The PC interface is busy with another process or defective Interference on the data cable. Overtemperature signal. Insert the main switch. Have an electrician check the mains. Input protection device restored. Contact the customer support service. Charge the batteries for at least 8 hours consecutively. Contact the customer support service. Contact the customer support service. Reduce the load connected to within the nominal value. Use the cable provided. Check that other SW applications are not interfering. Change position of the cable. Reduce the ambient temperature. 30 IOMITYTWXX00-GB_00
31 14 TECHNICAL SPECIFICATIONS Models ITY-TW010B / LB ITY-TW020B / LB ITY-TW030B / LB ITY-TW060B / LB ITY-TW100B / LB Power (VA) Power (W) Electrical specifications - Input ITY-TW010B / LB ITY-TW020B / LB ITY-TW030B / LB ITY-TW060B / LB ITY-TW100B / LB Mains voltage 230 Vac 230 Vac Frequency (nominal) 50/60 Hz Power factor 0,98 Electrical specifications - Output ITY-TW010B / LB ITY-TW020B / LB ITY-TW030B / LB ITY-TW060B / LB ITY-TW100B / LB Output voltage (Vout) 230 Vac (selectable 220 / 240 Vac) Frequency (nominal) 50/60 Hz Output frequency stability sync interval sync interval (for 50 Hz) Hz Hz (50 ± 0,2 Hz in battery mode) (50 ± 0,05 Hz in battery mode) Peak factor 3:1 Communication interface RS232 with DB9 connector Noise level 45 db 55 db Batteries ITY-TW010B / LB ITY-TW020B / LB ITY-TW030B / LB ITY-TW060B / LB ITY-TW100B / LB Typical back-up time (minutes) 10 / * 17 / * 9 / * 13 / * 9 / * * Back-up time depends on the configuration of the external battery cabinet. Standards ITY-TW010B / LB ITY-TW020B / LB ITY-TW030B / LB ITY-TW060B / LB ITY-TW100B / LB Standard EN Product certification Safety (EN) IEC EMC EN , IEC Protection level IP20 (compliant with a IEC 60529) Mechanical characteristics ITY-TW010B / LB ITY-TW020B / LB ITY-TW030B / LB ITY-TW060B / LB ITY-TW100B / LB Dimensions WxDxH (mm) 145x400x x460x x460x x570x x570x715 Weight B (kg) / Weight LB (kg) 14 / 7 34 / / / / 38 IOMITYTWXX00-GB_00 31
32 FRANÇAIS ITALIANO
NeTYS PR 1000-3000 VA
NeTYS PR 1000-3000 VA PRODUCT MANUAL CONTENTS 1. SAFETY STANDARDS...4 2. GENERAL DESCRIPTION...5 2.1. LED-BASED CONTROL AND DISPLAY PANEL...6 3. UNPACKING AND INSTALLATION...7 3.1. UNPACKING...7 3.2. ENVIRONMENTAL
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationMatch. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
More informationOnline UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.
More information10000HXL31/15000HXL31/20000HXL31
Table of Contents www.eaton.com/dxups USER MANUAL ON LINE UPS 10000HXL31/15000HXL31/20000HXL31 Uninterruptible Power Supply Table of Contents 1. Brief introduction 1.1 System and model description---------------------------------------------------------------------1
More informationLTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
More informationHow To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
More informationUninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User s manual Index Safety Warnings... 2 1 Introduction... 3 2 General Characteristics... 4 3 Receipt and site selection... 4 4 EXTERNAL
More informationNEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL
NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL info@tuncmatik.com / www.tuncmatik.com Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3.
More informationUser Manual 1K/2K/3K Online UPS
User Manual 1K/2K/3K Online UPS Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4. Operation...
More informationTIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
More information30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
More informationLIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase.
LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro online UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase LOCAL AREA NETWORKS (LAN) INTERNET CENTERS (ISP/ASP/POP) ELECTRO-MEDICAL
More informationUSER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
More informationon-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications
ZP110 on-line UPS 1, 2, 3, 6, 10kVA single/single phase LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs Emergency Devices (Lights/Alarms) Electro-Medical Devices
More informationUser Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply
User Manual English APC Smart-UPS SC 1000/1500 VA 110/120/230 Vac 2U Tower/Rack-Mount Uninterruptible Power Supply 990-1851C, 10/2005 Introduction The APC Uninterruptible Power Supply (UPS) is designed
More informationLiebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert
More informationInstallation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
More informationPowerware 5110 UPS User s manual
Powerware 5110 UPS 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care
More informationBack-UPS Pro 1300/1500 Installation and Operation
Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a
More informationTechnical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0
The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,
More informationSNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
More informationOperating instructions. AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014
Operating instructions AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014 Contents 1 Preliminary note 4 1.1 Notes on this document 4 1.2 Symbols used 4 2 Safety instructions 4 2.1 General 4 2.2 Installation
More informationUser s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationUser Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply
User Manual English APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC Tower Uninterruptible Power Supply 990-1587A 12/2005 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent
More informationWARRANTY CERTIFICATE AND CONDITIONS
NETYS PE 600-2000 VA Installations- und bedienungsanleitung DE Manual de instalación y uso ES Manuel d installation et d utilisation FR Installation and operating manual GB Manuale di installazione e uso
More informationUser Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply
User Manual English APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC Tower Uninterruptible Power Supply 990-1074C 06/2012 Introduction American Power Conversion Corporation (APC) is
More informationInstallation and Operation Back-UPS 1250, 1300, 1500
Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with
More informationUSER MANUAL Online UPS 1K/2K/3K Rack
USER MANUAL EN Online UPS 1K/2K/3K Rack Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation 2
More informationUSER MANUAL Online UPS 1K/2K/3K
USER MANUAL EN Online UPS 1K/2K/3K Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1.1. Transportation 2 1.2. Preparation 2 1.3. Installation 2 1.4. Operation 2 1.5.
More informationBroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
More informationUser s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
More informationAPC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
More informationGB USER S MANUAL GB 41
GB USER S MANUAL GB 41 INTRODUCTION Thanks you for choosing this product of the DIALOG DUAL range. Riello UPS are renowned specialists in the development and production of uninterruptible power supplies
More informationPowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
More informationUninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
More informationREAD FIRST! Universal Car/Air Adapter User Manual
AutoAir Manual 1/9/03 2:03 PM Page 1 READ FIRST! Universal Car/Air Adapter User Manual Congratulations! Your new Kensington Universal Car/Air Adapter is a highly efficient Universal Car/Air Adapter for
More informationHP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
More informationMulti DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication
More informationZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
More informationDelta UPS - Amplon Family. User Manual. E Series, Single Phase 1/2/3 kva. www.deltapowersolutions.com. The power behind competitiveness ON OFF ON LINE
The power behind competitiveness Delta UPS - Amplon Family E Series, Single Phase 1/2/3 kva User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationAmbient Temperature In Range Probe X
List of Events This section lists all events that are written to the Event Log. Some of these events can be configured through the Configuring Events to Take Actions page, and these are listed in the first
More informationGalleon 6-10K Online UPS. Voltronic Power Technology Corporation
Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection
More informationRIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.
Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of
More informationBack-UPS 650 VA 120 V with AVR (BX650CI-LM)
Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit
More informationHCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
More informationUSER MANUAL Online UPS 6K/10K RACK
USER MANUAL EN Online UPS 6K/10K RACK Uninterruptible Power Supply System Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationAC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
More informationIPS Magneto-Thermal protection device for electric loads.
Magneto-Thermal protection device for electric loads. S.r.l. via Landa, 80 40050 Monte San Pietro (BO) Italia tel +39 51 676544 Fax +39 51 676403 info@almaelettronica.it www.almaelettronica.it USER S MANUAL
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
More informationThree-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA
the Mega Power protection up to 5.4 MVA range is capable of a maximum system size of up to 5.4 MVA and specifically designed for demanding Data centre applications such as large DTC of banks / insurances,
More informationSmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
More informationOperation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a
Operation Manual Smart-UPS C Uninterruptible Power Supply Tower 1000/1500 VA 120/230 Vac su0813a Product Description The APC by Schneider Electric Smart-UPS is a high performance uninterruptible power
More informationSmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
More informationIP DSLAM IDL-2402. Quick Installation Guide
IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationSmart-UPS APC Smart-UPS 1000VA USB & Serial 230V
Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V APC Smart-UPS, 670 Watts / 1000 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, SmartSlot, USB Includes: CD with software, Smart UPS signalling
More informationBiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide
BiPAC 7800NL Wireless-N ADSL2+ Firewall Router Quick Start Guide BiPAC 7800NL Wireless-N ADSL2+ Firewall Router Billion BiPAC 7800NL Wireless-N ADSL2+ Firewall Router PLEASE READ THE QUICK START GUIDE
More informationProduct Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationOwner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7
Register online today for a chance to win a FREE Tripp Lite product! www.tripplite.com/warranty Owner s Manual Internet Office & BC Personal UPS Systems Not suitable for mobile applications. Important
More informationOZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
More informationAIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
More informationUPS OPERATING INSTRUCTIONS PROTECT A. PROTECT A. 500 PROTECT A. 700
UPS OPERATING INSTRUCTIONS PROTECT A. PROTECT A. 500 PROTECT A. 700 2 Thank you for deciding to purchase the PROTECT A. UPS from AEG Power Solutions. The following safety instructions are an important
More informationKeysight N4877A Clock Data Recovery and Demultiplexer 1:2
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started
More informationLine Interactive UPS
EN Line Interactive UPS PowerMust 636 LCD (650VA), Line Int., Schuko PowerMust 848 LCD (850VA), Line Int., Schuko PowerMust 636 LCD (650VA), Line Int., IEC PowerMust 848 LCD (850VA), Line Int., IEC PowerMust
More informationREGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
More informationCongratulations! Thank you!
TM-47 ORDERCODE D1370 Congratulations! You have bought a great, innovative product from DAP Audio. The DAP Audio Microphone range brings excitement to any venue. Whether you want simple plug-&-play action
More informationProduct and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
More informationCAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.
Product Description The APC by Schneider Electric Smart-UPS is a high performance uninterruptible power supply (UPS). The UPS provides protection for electronic equipment from utility power blackouts,
More informationSmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V
More informationinstabus KNX / EIB System System E F G H
Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA
More informationMIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
More information350, 500, 650 and 1000 MODELS
P D Technology Ltd PDT Power Series Instruction Manual Domestic, Commercial & Industrial PLEASE READ THE INSIDE FRONT COVER BEFORE INSTALLING THE PDT POWER SERIES 350, 500, 650 and 1000 MODELS P D Technology
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationTMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
More informationAPC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply
APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality
More informationSmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial MODEL NUMBER: SMART1500SLT Highlights 1.5kVA / 1500VA line interactive tower UPS; Sine wave output
More informationNC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
More informationEZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014
EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
More informationRIELLO ELETTRONICA. Master HP
RIELLO ELETTRONICA Master HP LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCS ELECTRO- MEDICAL DEVICES
More informationSmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1000RT2U Highlights 1kVA / 1000VA / 900W line-interactive 2U rack/tower UPS, Sine
More informationUPS Communicator. UPS Communicator English Manual Release 1.16 1
UPS Communicator 1 License for use The use of the SOFTWARE manufactured by Legrand (the MANUFACTURER) is free of charge. By proceeding with its installation of his own free will, the USER (an individual
More informationesata External Storage
esata External Storage Operation Manual DA-ES110 Before reading this manual This operation manual contains basic instruction on installing and using esata External Storage, an IDIS product. Users who are
More informationUser Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.
DONGGUAN SHENGYANG INDUSTRIAL CO., LTD SY WMVC Smart Grid Tie Microinverter User Manual Dongguan Shengyang Industrial Co., Ltd. ADD: No. 1 Shangxin Road, New Village, Xin An Community, Chang An Town, Dongguan
More informationekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.
ekil 3 KGK tecrübesi olmayan herhangi bir kii tarafından çalıtırılabilir. üçııı ıı ç ıöç ö çö ııı ç çıı çı ııııı ıüıçıııçııı ç ıç ö çı ııç ıı Akü Modu Akü düük Aırı yük Arıza Bypas modu 4 saniyede
More informationSafety information. MSX-Box. ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany
DIN EN ISO9001:2008 certified ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany Phone: +49 7229 1847 0 Fax: +49 7229 1847 222 E-mail: info@addi-data.com Safety information
More informationMIC-BP4 Bi-Phase Converter Card For the MIC400 series camera
MIC-BP4 Bi-Phase Converter Card for the MIC400 PTZ Camera Series Bosch Security Systems EN Installation and Operation Manual BP4 Bi-phase card Installation and Operation Manual AAAEN 2 MIC-BP4 Bi-Phase
More informationDisturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
More informationQuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview
Overview The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. These new UPSs are designed to provide advanced power protection (or increased uptime and data corruption avoidance)
More information4.0 UPS dedicated to ICT for unmatched energy savings
4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.
More informationPC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power
More informationPhotovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
More informationSmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
More informationUPS Network Interface. Quick InstallationGuide
UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
More informationMobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
More informationLS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
More information