USB Data Acquisition Product Selection Guide

Size: px
Start display at page:

Download "USB Data Acquisition Product Selection Guide"

Transcription

1 Page 1 of 6 Document Type: Tutorial NI Supported: Yes USB Data Acquisition Product Selection Guide Overview To select the correct USB data acquisition (DAQ) device for your measurement application, follow these simple steps: 1. Select the family that best fits your general application needs. 2. Use the selection table for that family to choose the correct product. 3. Click on the product name for datasheets and pricing. Data Acquisition Specifications A Glossary of DAQ terminology Table of Contents 1. USB Data Acquisition Families 2. USB High Performance Multifunction DAQ 3. USB DAQ with Signal Conditioning 4. USB DIO 5. USB Low Cost Multifunction DAQ USB Data Acquisition Families Input Output input input sampling rate voltage range Simultaneous sampling Built-in signal conditioning Isolation analog output output output update rate Digital I/O USB High Performance DAQ SE/8 DI Up to 800 ks/s Up to ± 60 V USB DAQ with Signal Conditioning 4 DI Up to 24 Up to 20 ks/s USB DIO Low-Cost Multifunction DAQ 8 SE/4 DI Up to 14 Up to 48 ks/s ± 10 V ± 20 V» USB/ DAQ System with Configurable by module Up to 200kS/s Up to ± 300V Available by»» Up to 2 0 Up to 300 S/s Available by Up to 150 S/s Up to Configurable by module Up to 555S/s Configurable by module CTR/timers Up to 2, 24- bit 0 32 bit event 1, 32-bit simple event External Connection

2 Page 2 of 6 Triggering counter counter Triggering» Digital External Connection Shielded, metal» enclosure Signal Conditioning» terminal, BNC, and Dsub connector options Removable screwterminal connectors Breadboard area for custom frontend circuitry USB cable strain relief Mounting holes»»»»» Separately External power» Separately» Bus power Bus power Bus power BNC for external connections Connections vary by module Mounts in Chassis Chassis power Selfcalibration certificate interface,. or Traditional NI-DAQ (Legacy) Included Ready-to-Run Data Logger or Logger or C, Logger or On all devices» On some devices On no devices USB High Performance Multifunction DAQ Input input input sampling rate voltage range NI DAQPad- 6015/6016 NI DAQPad- 6020E 9201/ /9215A 16 SE/8 DI 16 SE/8 DI 8 SE 4 DI ks/s 100 ks/s ± 0.05 to ± 10 V ± 0.05 to ± 10 V 500 ks/s or 800 ks/s ± 10 V or ± 60 V 20kS/s/ch or 100kS/s/ch ± 10 V

3 Page 3 of 6 Output Triggering output output output range output update rate ± 10 V ± 10 V 300 S/s 20 S/s Digital I/O 8 or 32 8 CTR/timers 2, 24-bit 2, 24-bit Triggering Digital Digital Shielded, metal enclosure Signal Breadboard area for custom front-end circuitry Signal Conditioning USB cable strain relief Yes 15cm or 30cm Yes Yes terminals, BNC, or mass termination*** Mass termination or BNC terminal, D- Sub Terminal, BNC (9215A only) Only on 6015 with mass termination 6015 Yes Built in Channel-to- Earth isolation Built in Channel-to- Earth isolation Mounting holes Yes Yes Optional 6016 OEM kit OEM OEM Configuration available External power External power Bus power Bus Self-calibration Yes Yes certificate interface Included Readyto-Run Data Logger Operating System Yes Yes Traditional NI- DAQ (Legacy) Windows Windows Windows (9215A only),ni- DAQmx C, (9215A only) (9215A only) Windows, Mac OSX*, Linux* *Mac OSX and Linux support using driver only ** support with driver only ***NI DAQPad-6016 only available with screw terminal connectivity Return to top USB DAQ with Signal Conditioning Input input input sampling rate voltage range 9211/9211A DI 8 SE 4DI S/s 800 ks/s 50 ks/s ± 80 mv ± 60 V ± 5 V

4 Page 4 of 6 Simultaneous sampling Built-in signal conditioning Isolation analog Shielded, metal enclosure Signal Removable screwterminal connectors Breadboard area for custom front-end circuitry USB cable strain relief Yes CJC for thermocouple measurements Channel-to-Earth Channel-to- Earth AC Coupling and IEPE None Yes Yes Yes Terminals Terminals, D- Sub BNC Yes Yes No No No No Yes Yes Yes Mounting holes Yes Yes Yes Bus Bus power Bus Self-calibration certificate interface Included Ready-to- Run Data Logger Operating System Yes Yes Yes (9211A only) ** (9211A only) Windows, Linux (9211 only), MAC OSX(9211 only)* Windows ** Available with Sound & Vibration Toolkit at bundle price Windows *Mac OSX and Linux support using driver only ** support with driver only USB DIO Triggering Digital I/O Digital Output driver type CTR/timers 6501 Features USB cable strain relief 6507/ open-drain, 5V 1, 32-bit simple event counter Userdefined power up states, 2- wire handshaking Removable screwterminals input 11 to 30 V sink output 6 to 30 V 0.75 A/ch source Relay output 2 A (30 VDC) 1 A (60 VDC) electromechanical relay Built in screwterminals Bank Isolation terminal, D-Sub Bank Isolation terminal, D-Sub Bank Isolation Terminal

5 Page 5 of 6 Optional Configurations OEM available with mass termination board Bus power Bus power Bus interface Included Ready-to-Run Data Logger Operating System or ** None Windows, Mac OSX*, Linux* Bus / (External power for up to 30V sourcing) NI-DAQ 7.4 None C, Logger C, Logger Bus Windows Windows Windows Windows *Mac OSX and Linux support using driver only ** support with driver only USB Low Cost Multifunction DAQ Input Output Triggering input 8 SE/4 DI 8 SE/4 DI input sampling rate 10kS/s 48 ks/s voltage range ± 1 to ± 20 V ± 1 to ± 20 V output 2 2 output output range 0-5 V 0-5 V output update rate 150 S/s 150 S/s Digital I/O Digital Output driver type CTR/timers Open-drain 1, 32-bit simple event counter Each channel selectable (open-drain/push-pull) 1, 32-bit simple event counter Triggering Digital Digital Removable screw-terminal connectors Yes Yes USB cable strain relief Yes Yes Optional Configurations OEM/Student OEM/Student Bus Bus power interface Included Ready-to-Run Data Logger Operating System, or ** Windows, Mac OSX*, Linux*, or ** Windows, Mac OSX*, Linux* *Mac OSX and Linux support using driver only ** support with driver only

6 Page 6 of 6 Reader Comments Submit a comment» What is the maximum input frequency for the counter? - Dec 13, 2005 error in footnote of first table In Apple Safari 2.0, Mozilla Firefox for Mac and Microsoft Explorer for Mac, the footnote for the first table incorrectly indicates that a tilde (instead of a black dot) denotes "on all devices". - Jul 4, 2005 A helpful comparison would be to indicate which devices you are stuck with MS Windows and which have Linux drivers available! Thank you, -Jay- - Jun 3, 2005 Legal This tutorial (this "tutorial") was developed by National Instruments ("NI"). Although technical support of this tutorial may be made available by National Instruments, the content in this tutorial may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this content with each new revision of related products and drivers. THIS TUTORIAL IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE ( My Profile Privacy Legal Contact NI 2007 National Instruments Corporation. All rights reserved. this Page

ECONseries Low Cost USB DAQ

ECONseries Low Cost USB DAQ ECONseries Low Cost USB Data Acquisition Modules ECONseries Low Cost USB DAQ The ECONseries is a flexible yet economical series of multifunction data acquisition modules. You choose the number of analog

More information

Measuring Temperature withthermistors a Tutorial David Potter

Measuring Temperature withthermistors a Tutorial David Potter NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in

More information

NEW. EVEN MORE data acquisition and test stand automation

NEW. EVEN MORE data acquisition and test stand automation NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware

More information

SignalPad Data Logging and Analysis Software

SignalPad Data Logging and Analysis Software SignalPad Data Logging and Analysis Software Overview SignalPad is a data logging and analysis application developed with National Instruments LabVIEW. The configuration-based user interface provides ready-to-run

More information

Simplify Data Acquisition with a Built-in LXI Web Server

Simplify Data Acquisition with a Built-in LXI Web Server M E A S U R E M E N T T I P S Volume 9, Number 3 Simplify Data Acquisition with a Built-in LXI Web Server Snapshot: Make temperature measurements quickly and easily There are many applications in which

More information

Screen 3.5" Color Touch 4.3" Color Touch Keypad or Function Keys Programming Com Port, Built-in

Screen 3.5 Color Touch 4.3 Color Touch Keypad or Function Keys Programming Com Port, Built-in Samba PLC+HMI SM35-J-RA22 SM43-J-RA22 Installation Guide 12 Digital Inputs, including 1 HSC/Shaft-encoder Inputs, 2 Analog Inputs, 2 PT100/TC inputs 8 Relay Outputs 2 Analog Outputs General Description

More information

Introduction to Data Acquisition

Introduction to Data Acquisition Introduction to Data Acquisition Overview This tutorial is part of the National Instruments Measurement Fundamentals series. Each tutorial in this series, will teach you a specific topic of common measurement

More information

DT9836 Series. BNC Connection Box. OEM Embedded Version

DT9836 Series. BNC Connection Box. OEM Embedded Version BUS: USB DT9836 Type: Simultaneous Multifunction DT9836 Series Simultaneous Analog Input Multifunction Data Acquisition USB Modules Simultaneously Captured Analog Input Channels 12 separate 16-bit A/D

More information

DAQ in MATLAB HANS-PETTER HALVORSEN, 2012.09.11

DAQ in MATLAB HANS-PETTER HALVORSEN, 2012.09.11 Telemark University College Department of Electrical Engineering, Information Technology and Cybernetics DAQ in MATLAB HANS-PETTER HALVORSEN, 2012.09.11 Faculty of Technology, Postboks 203, Kjølnes ring

More information

Three Levels of Data-Logging Software from National Instruments

Three Levels of Data-Logging Software from National Instruments Three Levels of Data-Logging Software from National Instruments One of the most common data acquisition applications is simply logging acquired data to disk or a database for future analysis. Most National

More information

National Instruments UK. UK Price List

National Instruments UK. UK Price List National Instruments UK 779818-03 INFINITY TECHNOLOGY KIT(FOR HIGH SCHOOL ONLY) 309.00 781010-01 NI ELVIS II HARDWARE ONLY (FOR PLTW US ONLY) 1,749.00 778010-23 LABVIEW DSP BUNDLE (ACADEMIC ONLY) 779819-03

More information

NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position

More information

DATENBLATT USB-DIO32HS USB-DIO32HS-OEM. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich.

DATENBLATT USB-DIO32HS USB-DIO32HS-OEM. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich. DATENBLATT USB-DIO32HS HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich. TELEFON + 49 (0) 81 41/36 97-0 TELEFAX + 49 (0) 81 41/36 97-30 E-MAIL info@plug-in.de

More information

Product Functional description Price in CZK

Product Functional description Price in CZK DATA ACQUISITION Data Acq Software SP0811-CD SP0970-CD SP1305-CD SP8051-CD LV-Link (DT-Open Layers connection to LabVIEW ) 4 226 DTx-EZ (ActiveX Controls for Windows 2000/XP); this can not be ordered because

More information

Servo Motors (SensorDAQ only) Evaluation copy. Vernier Digital Control Unit (DCU) LabQuest or LabPro power supply

Servo Motors (SensorDAQ only) Evaluation copy. Vernier Digital Control Unit (DCU) LabQuest or LabPro power supply Servo Motors (SensorDAQ only) Project 7 Servos are small, relatively inexpensive motors known for their ability to provide a large torque or turning force. They draw current proportional to the mechanical

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

USB-6008/6009. Contents USER GUIDE. This user guide describes how to use the National Instruments USB-6008/6009 data acquisition (DAQ) devices.

USB-6008/6009. Contents USER GUIDE. This user guide describes how to use the National Instruments USB-6008/6009 data acquisition (DAQ) devices. USER GUIDE USB-6008/6009 Contents This user guide describes how to use the National Instruments USB-6008/6009 data acquisition (DAQ) devices. Introduction... 2 Safety Guidelines... 3 Software... 5 Logging

More information

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM43-J-T20/ SM35-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs are set to pnp), 8 Relay Outputs 12 Digital

More information

CALIBRATION PROCEDURE NI 9219. Contents. Software Requirements. ni.com/manuals

CALIBRATION PROCEDURE NI 9219. Contents. Software Requirements. ni.com/manuals CALIBRATION PROCEDURE NI 9219 Français Deutsch ni.com/manuals Contents This document contains information for calibrating the National Instruments 9219. For more information on calibration, visit ni.com/calibration.

More information

Data Acquisition in LabVIEW

Data Acquisition in LabVIEW Telemark University College Department of Electrical Engineering, Information Technology and Cybernetics Data Acquisition in LabVIEW HANS- PETTER HALVORSEN, 2013.08.16 Faculty of Technology, Postboks 203,

More information

NI 6601/6602. Contents CALIBRATION PROCEDURE. ni.com/manuals

NI 6601/6602. Contents CALIBRATION PROCEDURE. ni.com/manuals CALIBRATION PROCEDURE NI 6601/6602 Français Deutsch ni.com/manuals This document contains information and instructions for calibrating the National Instruments 6601/6602 data acquisition devices. Contents

More information

DAQ Getting Started Guide

DAQ Getting Started Guide DAQ Getting Started Guide This guide describes how to confirm your NI data acquisition (DAQ) device is operating properly. Install your application and driver software, then your device, using the instructions

More information

Mounting HP Desktop Mini Rack Mount Tray Kit HP Desktop Mini Security/Dual VESA Sleeve

Mounting HP Desktop Mini Rack Mount Tray Kit HP Desktop Mini Security/Dual VESA Sleeve Mounting HP Desktop Mini Rack Mount Tray Kit HP Desktop Mini Security/Dual VESA Sleeve Optical Drive HP Desktop Mini DVD Super Multi-Writer ODD Expansion Module Input / Output / HDD HP Desktop Mini 500GB

More information

K-Type Thermocouple Sensor User s Guide

K-Type Thermocouple Sensor User s Guide K-Type Thermocouple Sensor User s Guide 1 TABLE OF CONTENTS: 1 INTRODUCTION... 2 2 TYPICAL APPLICATION:... 2 3 INSTALLATION RULES:... 2 3.1 Connecting the sensor to M1/MD4 data logger:... 2 3.2 Connecting

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections

More information

Benefits and Potential Dangers of Using USB for Test & Measurement Applications. Benefits of Using USB for Test and Measurement

Benefits and Potential Dangers of Using USB for Test & Measurement Applications. Benefits of Using USB for Test and Measurement Benefits and Potential Dangers of Using USB for Test & Measurement Applications What is USB? USB (Universal Serial Bus) is a standard that was developed by a group of manufacturers (including Intel, Microsoft,

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual.

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual. DBK42 16-Slot 5B Signal Conditioning Module Overview 1 Hardware Setup 2 DBK42 Connection 2 DBK42 Configuration 2 5B Module Connection 2 Power Considerations 2 Terminal Block Connections 3 DaqBoard/2000

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc. http://www.spincore.com

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc. http://www.spincore.com RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc. http://www.spincore.com Congratulations and thank you for choosing a design from SpinCore Technologies, Inc. We appreciate your business!

More information

SCXI -1303 32-CHANNEL ISOTHERMAL TERMINAL BLOCK

SCXI -1303 32-CHANNEL ISOTHERMAL TERMINAL BLOCK INSTALLATION GUIDE SCXI -1303 32-CHANNEL ISOTHERMAL TERMINAL BLOCK Introduction This guide describes how to install and use the SCXI-1303 terminal block with SCXI-1102, SCXI-1102B, SCXI-1102C, and SCXI-1100

More information

Allen-Bradley/Rockwell

Allen-Bradley/Rockwell MANUFACTURER DATA SHEET Analog I/O Module Manufacturer: Allen-Bradley/Rockwell Model Number: 1746-NI4 See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014624-18 VendorPartNumber:

More information

HIGH RELIABILITY POWER SUPPLY TESTING

HIGH RELIABILITY POWER SUPPLY TESTING HIGH RELIABILITY POWER SUPPLY TESTING Dale Cigoy Keithley Instruments, Inc. The reliability of a power supply must match or exceed the rest of the system in which it is installed. Generally, this requires

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

Cable Connection Procedures for Cisco 1900 Series Routers

Cable Connection Procedures for Cisco 1900 Series Routers CHAPTER 5 Cable Connection Procedures for Cisco 1900 Series Routers This document describes how to connect your Cisco 1941 integrated services router to a power source and to networks and external devices.

More information

Allen-Bradley/Rockwell

Allen-Bradley/Rockwell MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

USB-AD16f Data acquisition system (USB)

USB-AD16f Data acquisition system (USB) Data acquisition system (USB) Measurement & Control. Extremely powerful. Precisely record and output signals with the USB-AD16f: The high-performance USB data acquisition system accomodated in a stable

More information

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module

More information

ADC-20/ADC-24 Terminal Board. User Guide DO117-5

ADC-20/ADC-24 Terminal Board. User Guide DO117-5 ADC-20/ADC-24 Terminal Board User Guide DO117-5 Issues: 1) 8.11.05 Created by JB. 2) 13.12.05 p10: added 0V connection to thermocouple schematic. 3) 22.3.06 p11: removed C1. 4) 20.8.07 New logo. 5) 29.9.08

More information

NI 9211 Datasheet DATASHEET. 4 TC, ±80 mv, 24 Bit, 14 S/s Aggregate

NI 9211 Datasheet DATASHEET. 4 TC, ±80 mv, 24 Bit, 14 S/s Aggregate DATASHEET NI 9211 Datasheet 4 TC, ±80 mv, 24 Bit, 14 S/s Aggregate Screw-terminal connectivity 50 Hz/60 Hz noise rejection 250 Vrms, CAT II, channel-to-earth isolation The NI 9211 thermocouple input module

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Personal Daq/50 Series USB Data Acquisition Modules

Personal Daq/50 Series USB Data Acquisition Modules USER S MANUAL Personal Daq/50 Series USB Data Acquisition Modules Personal Daq/54 Personal Daq/55 Personal Daq/56 PDQ1 PDQ2 Personal Daq/50 Series p/n 491-0901 rev 7.0 *372182A-01* 372182A-01 Measurement

More information

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.

More information

Unpack and Install the Devices, Accessories, and Cables

Unpack and Install the Devices, Accessories, and Cables READ ME FIRST NI-DAQmx and DAQ Device Installation Guide Français Deutsch ni.com/manuals Install your software before installing new hardware. Install Application Software Install NI application software,

More information

Why to use isolated amplifiers

Why to use isolated amplifiers Why to use isolated amplifiers AppNote v1.0 www.dewesoft.com Table of Contents Table Of Contents 1Introduction...1 1.1Amplifier technologies...1 1.1.1Single-ended amplifier...1 1.1.2Differential amplifier...1

More information

NI-DAQ mx Base 3.x. Contents GETTING STARTED GUIDE

NI-DAQ mx Base 3.x. Contents GETTING STARTED GUIDE GETTING STARTED GUIDE NI-DAQ mx Base 3.x Contents This guide describes how to install and configure the NI-DAQmx Base 3.x software and a data acquisition (DAQ) device. This guide also describes how to

More information

Wireless Data Acquisition in. LabVIEW

Wireless Data Acquisition in. LabVIEW Telemark University College Department of Electrical Engineering, Information Technology and Cybernetics Wireless Data Acquisition in HANS-PETTER HALVORSEN, 2011.02.03 LabVIEW Faculty of Technology, Postboks

More information

MAC-8. Technical Documentation AC Voltage Input Submodule. Please keep for further use!

MAC-8. Technical Documentation AC Voltage Input Submodule. Please keep for further use! MAC-8 Technical Documentation AC Voltage Input Submodule Please keep for further use! Edition date/rev. date: 16.12.1998 Document no./rev. no.: TRS - V - BA - GB - 0029-00 Software version: 1.0 File name:

More information

USB-AD14f Data Acquisition System (USB)

USB-AD14f Data Acquisition System (USB) Data Acquisition System (USB) Measurement & Control. Super-Low Priced. Record and output signals with the USB-AD14f. The USB data acquisition system accomodated in a stable aluminum housing is ideal for

More information

"Creating an automated test station to verify AdBlue pump modules in hydraulic test." - Jiří Kubíček, Robert Bosch, spol. s r.o.

Creating an automated test station to verify AdBlue pump modules in hydraulic test. - Jiří Kubíček, Robert Bosch, spol. s r.o. Functional Tester Based on PXI for BOSCH AdBlue Pump "Creating an automated test station to verify AdBlue pump modules in hydraulic test." - Jiří Kubíček, Robert Bosch, spol. s r.o. The Challenge: Creating

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

NI 653x Cable Adapter

NI 653x Cable Adapter USER GUIDE NI 653x Cable Adapter Contents The NI 653x cable adapter interfaces with National Instruments high-speed digital I/O (DIO) devices. The cable adapter provides an easy way to connect the Very

More information

6703/6704 ANALOG OUTPUT DEVICE CALIBRATION PROCEDURE

6703/6704 ANALOG OUTPUT DEVICE CALIBRATION PROCEDURE 6703/6704 ANALOG OUTPUT DEVICE CALIBRATION PROCEDURE Version 1.0 Introduction: This Document s Scope The following procedure for verifying and calibrating the National Instruments 6703/6704 analog output

More information

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings. TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

INSTALLATION INSTRUCTIONS 160-Pin Cable for the NI PXI-2530B

INSTALLATION INSTRUCTIONS 160-Pin Cable for the NI PXI-2530B INSTALLATION INSTRUCTIONS 160-Pin Cable for the NI PXI-2530B Contents This guide describes how to connect and use the National Instruments 160-pin shielded cable for the NI PXI-2530B which has a maximum

More information

USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright 2005-2013 Pico Technology Limited. All rights reserved.

USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright 2005-2013 Pico Technology Limited. All rights reserved. USB TC-08 Temperature Logger User's Guide USB TC-08 User's Guide I Contents 1 Introduction...1...1 1 Overview...1 2 Leg al information...2 3 Safety warning...3 4 Company details 2 Getting Started...4...4

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

USB-TC. Thermocouple Measurement. User's Guide

USB-TC. Thermocouple Measurement. User's Guide USB-TC Thermocouple Measurement User's Guide Document Revision 9 January 2014 Copyright 2014 Your new Measurement Computing product comes with a fantastic extra Management committed to your satisfaction!

More information

Advanced Data Capture and Control Systems

Advanced Data Capture and Control Systems Advanced Data Capture and Control Systems Tronisoft Limited Email: sales@tronisoft.com Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document

More information

Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions

Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions The Need for Integrated Automation and Measurement Manufacturing lines consist of numerous decoupled systems for

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

USER MANUAL V5.0 ST100

USER MANUAL V5.0 ST100 GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2

More information

Berkeley Audio Design Alpha USB

Berkeley Audio Design Alpha USB QUICK USER GUIDE v1.2.2 Berkeley Audio Design Alpha USB The Alpha USB is an asynchronous High Speed USB to digital audio interface designed to provide the highest possible audio quality from computer audio

More information

Technical Note Series

Technical Note Series Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment

More information

Utilizing the Latest Technologies in Data Acquisition

Utilizing the Latest Technologies in Data Acquisition Utilizing the Latest Technologies in Data Acquisition Agenda Computer Based DAQ Fundamentals Utilizing New Technologies 2 PC-Based Data Acquisition (DAQ) Transducer Signal Signal Conditioning DAQ Software

More information

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER 4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure StarTech ID: SAT3540U3ER The SAT3540U3ER 4-Drive USB 3.0/eSATA to 3.5" SATA RAID Enclosure is a high-performance external RAID storage

More information

USB 3.0 to SATA 3.5" Enclosure Installation Guide

USB 3.0 to SATA 3.5 Enclosure Installation Guide USB 3.0 to SATA 3.5" Enclosure Installation Guide Introduction The USB 3.0 to SATA 3.5" Enclosure is designed to support USB equipped computers. This enclosure provides large capacity mobile storage using

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

NI USB-9215 Series. Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 VDC, 16-Bit Simultaneous Sampling Analog Input Devices

NI USB-9215 Series. Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 VDC, 16-Bit Simultaneous Sampling Analog Input Devices USER GUIDE AND SPECIFICATIONS NI USB-9215 Series 4-Channel, ±10 VDC, 16-Bit Simultaneous Sampling Analog Input Devices Introduction This user guide describes how to use the National Instruments USB-9215

More information

1.44 kw Programmable DC Power Supplies XLN Series

1.44 kw Programmable DC Power Supplies XLN Series Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable

More information

Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out

Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out SIMATIC S7-200 EM223 Digital Combination Modules EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out Table 1 Specifications for EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out EM223 2VDC In/Out 6ES7 2231BF200XA0

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements.

The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements. HARDWARE DESCRIPTION The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements. BASE MODULE GO LINE Digital I/O 8 Analog Out AUX 1

More information

EXTERNAL DIMENSIONS AND PARTS

EXTERNAL DIMENSIONS AND PARTS FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special

More information

UM-22416-A. DT9837 User s Manual

UM-22416-A. DT9837 User s Manual UM-2241-A DT9837 User s Manual First Edition October, 200 Copyright 200 by Data Translation, Inc. All rights reserved. Information furnished by Data Translation, Inc. is believed to be accurate and reliable;

More information

RUDAT-6000-30. Key Features. Mini-Circuits www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.

RUDAT-6000-30. Key Features. Mini-Circuits www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits. USB / RS232 Programmable Attenuator 0 30 db, 0.25 db step 1 to 6000 MHz The Big Deal Attenuation range, 30 db Fine attenuation resolution, 0.25 db Short attenuation transition time (650 ns) Compact size,

More information

ECEN 1400, Introduction to Analog and Digital Electronics

ECEN 1400, Introduction to Analog and Digital Electronics ECEN 1400, Introduction to Analog and Digital Electronics Lab 4: Power supply 1 INTRODUCTION This lab will span two lab periods. In this lab, you will create the power supply that transforms the AC wall

More information

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Vibration analysis and monitoring Compact. Powerful. Modern technology. Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device

More information

COST EFFECTIVE EMBEDDED POWER MONITOR. Kevin Harris Marketing Manager TEAL Electronics

COST EFFECTIVE EMBEDDED POWER MONITOR. Kevin Harris Marketing Manager TEAL Electronics by Kevin Harris Marketing Manager TEAL Electronics Abstract Embedding an Ethernet connected web-based low-cost power monitor into a permanently installed Original Equipment Manufacturer s (OEM) 3-phase

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value. Vision OPLC V350-35-RA22/V350-J-RA22 Technical Specifications The Unitronics V350-35-RA22/V350-J-RA22 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog,

More information

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip NI 6585 Specifications This document lists the specifications of the National Instruments 6585 FlexRIO low-voltage differential (LVDS) adapter module. Pair these specifications with your FPGA module specifications.

More information

Trigno/Vicon System Integration

Trigno/Vicon System Integration Delsys and Vicon Analog Integration Motion capture systems will often have the ability to sample analog data channels as a convenient means for synchronizing external data streams with motion capture data.

More information

THE INPUT/OUTPUT SYSTEM. Key Points

THE INPUT/OUTPUT SYSTEM. Key Points M O D U L E T W O THE 2 INPUT/OUTPUT SYSTEM Key Points In the first module, you learned about the basic architecture and operation of the Allen-Bradley Micrologix 1000, including a brief introduction to

More information

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input

More information

Using installed Fieldbus Wiring to carry Ethernet Communications

Using installed Fieldbus Wiring to carry Ethernet Communications Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading

More information

Universal Vehicle Power Supply 9007AX01. Installation Instructions

Universal Vehicle Power Supply 9007AX01. Installation Instructions Universal Vehicle Power Supply 9007AX01 Installation Instructions Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in

More information

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw Machine-to-Machine Management System Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw Automated Machine Control Sensor Data Collection and Analytics Plug

More information

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER 4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure StarTech ID: SAT3540U3ER The SAT3540U3ER 4-Drive USB 3.0/eSATA to 3.5" SATA RAID Enclosure is a high-performance external RAID storage

More information

xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide

xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide Part Number 900-685 Revision A June 2013 Copyright and Trademark Contacts 2013 Lantronix, Inc.. All rights reserved. No part of the contents

More information