DuPont Tyvek Fluid Applied WB Commercial Installation Guidelines

Size: px
Start display at page:

Download "DuPont Tyvek Fluid Applied WB Commercial Installation Guidelines"

Transcription

1 DuPont Tyvek Fluid pplied W DuPont Tyvek Fluid pplied Flashing and Joint ompound DuPont Tyvek Fluid pplied W ommercial Installation Guidelines METHODS FOR SUPERIOR PROTETION GINST IR ND WTER INTRUSION

2 DuPont Tyvek Fluid pplied ir arrier System DuPont Tyvek Fluid pplied W DuPont Tyvek Fluid pplied weather barrier (W) is a vapor permeable, low VO, single-component product with excellent elasticity and flexibility. It is easily applied in one coat and has extremely low shrinkage during curing. DuPont Tyvek Fluid pplied Flashing and Joint ompound full bodied, trowel applied, vapor permeable elastomeric flashing material. It is used to coat rough openings for windows and doors, to fill seams, cracks and holes in the substrate, to seal around penetrations and to treat joints and transitions between building components. DuPont Tyvek Fluid pplied Flashing - rush Formulation brush applied, vapor-permeable elastomeric flashing material used to coat rough openings for windows and doors. DuPont Sealant for Tyvek Fluid pplied System Non-vapor permeable sealant specifically designed to work with the DuPont Tyvek Fluid pplied system. DuPont Sealant for Tyvek Fluid pplied System has excellent adhesion and elongation. It should be used to seal around window, doors, and penetrations. DuPont ommercial Self-dhered Flashing DuPont StraightFlash premium self-adhered membrane used for flashing windows and doors, to treat transitions and for terminations. It is made with DuPont Tyvek and a 100% butylbased adhesive layer. DuPont FlexWrap NF premium extendable self-adhered flashing material that efficiently conforms around corners and irregular shapes. It is made with DuPont Tyvek and a 100% butyl-based adhesive layer. opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 2

3 Table of ontents pplicable Products... 3 Recommended Primers... 3 Weather arrier and Energy onservation odes and Standards... 4 Warranty Information... 4 Special onsiderations for MU... 4 Installation Instructions... 5 Detailing... 6 Foundation... 6 Top of Wall... 6 Transitions...7 Transitions to DuPont Tyvek uilding Wrap Products... 8 Penetrations... 8 rick Ties, ladding Supports, and Furring Strips... 9 pplication Over Sheathing... 9 Joint Treatment Methods Repair Equipment Recommendations lean Up Health and Safety Disposal Facade/Exterior onsiderations pplicable Products Fluid pplied Products PRODUT QUNTITY OVERGE DuPont Tyvek Fluid pplied W 5 gal, 50 gal sf/gal* DuPont Tyvek Fluid pplied Flashing and Joint ompound 10.3 oz, 28 oz, 3.5 gal sf/gal* DuPont Tyvek Fluid pplied Flashing and Joint ompound (for gypsum sheathing seam treatment) 10.3 oz, 28 oz, 3.5 gal lf/oz DuPont Tyvek Fluid pplied Flashing - rush Formulation 10.3 oz, 28 oz, 3.5 gal sf/gal* DuPont Sealant for Tyvek Fluid pplied System 10.3 oz, 28 oz N/ * Estimated surface coverage at 25 mils thick. Self-dhered Flashing Products PRODUT DIMENSIONS RE DuPont FlexWrap NF 6 in x 75 ft sq ft 9 in x 75 ft sq ft DuPont StraightFlash 4 in x 150 ft 50 sq ft 9 in x 125 ft sq ft Recommended Primers* (for self-adhered flashing) MNUFTURER PRODUT NME DuPont DuPont dhesive Primer 3M Hi-Strength 90 Denso utyl Primer (spray or can) * pply per manufacturers guidelines. DuPont assumes no liability in use of non-dupont recommended products; installers need to evaluate suitability of recommended products in their end-use applications. opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 3

4 Weather arrier & Energy onservation odes and Standards The 2009 International uilding ode (Section Weather Protection) requires that exterior walls shall provide the building with a weather resistant exterior wall envelope. The exterior wall envelope shall include flashing, as described in Section DuPont Tyvek Fluid pplied System has been tested to the following standards. STM E 331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and urtain Walls by Uniform Static Pressure STM E 2178 Standard Test Method for ir Permeance of uilding Materials STM E 2357 Standard Test Method for Determining ir Leakage of ir arrier ssemblies STM E 283 Standard Test Method for Determining Rate of ir Leakage Through Exterior Windows, urtain Walls and Doors Under Specified Pressure Differences cross the Specimen. Energy onservation odes for commercial buildings are being adopted in many regions across the U.S. DuPont Tyvek Fluid pplied Weather arrier System products meet the following codes and guidelines. SHRE 90.1 Model Energy ode air barrier requirements Minnesota ommercial Energy ode, Section , Section Massachusetts State uilding ode 780 MR 120. Wisconsin uilding ode, Energy onservation, hapter omm 63 Michigan uilding ode Rhode Island uilding ode Georgia uilding ode Florida uilding ode Warranty Information If interested in reviewing warranty coverage, please see DuPont Tyvek Fluid pplied W Products 10 Year limited warranty at Special onsiderations 1. Suitable substrates for Tyvek Fluid pplied products include concrete masonry unit (MU), concrete (48 hrs. for green concrete), exterior gypsum, OS, plywood, wood, treated wood and metal. 2. Tyvek Fluid pplied products can be applied to damp surfaces. surface is considered damp if there is no visible water on the surface and no transfer of water to the skin when touched. 3. Do not install on a wall that does not feature a continuous path for moisture drainage. Tyvek Fluid pplied products are designed for above grade application and should not be installed below grade. 4. Tyvek Fluid pplied products should be applied when air and surface temperatures are above 25 F and a maximum surface temperature of 140 F (60 ). Do not install once ambient temperature exceeds 95 F (35 ), unless surface is shaded. 5. Tyvek Fluid pplied products may be overcoated once a touch-free skin has formed. Exterior insulation and/or cladding may be installed once the membrane has cured sufficiently to resist damage during installation. Skin time is 1-2 hrs, and 25 mil cures in 24 hrs at 70 F (20 ), 50% RH. 6. Tyvek Fluid pplied products should be stored in a clean, dry environment, at F, (10-27 ). Products may be temporarily stored ( up to one month) in a covered environment, at 20 F to 120 F, intermittently. ontinuous storage at high temperatures will reduce the shelf life of these products. Products temporarily stored outside should be stored under cover. 7. Opened pails and drums of fluid applied product should be covered with plastic to slow cure rate. 8. DuPont requires that fluid applied product be covered within 9 months of installation. 9. efore reusing a previously opened container, first remove any cured material that may have formed at the top. DuPont self-adhered flashing products perform best when air and surface temperatures are above 25 F ( 4 ). 10. recommended primer is required when applying DuPont self-adhered flashing products on concrete, masonry, and fiber faced exterior gypsum board substrates. Priming is generally not required for adhering DuPont self-adhered flashing products to wood. However, adverse weather conditions or colder temperatures may require a primer to promote adhesion. Priming is not required when applying Tyvek Fluid pplied products, except when applying onto cut edges of exterior gypsum sheathing. 11. DuPont Tyvek Fluid pplied products must not come in contact with the building wrap products due to potential impact on performance properties. See page 8 for transitions to DuPont Tyvek buildingwrap products. 12. Stirring not necessary. If separation should occur, you can gently fold material until mixture is uniform. void any type of mixing that will introduce air into the product. 13. sphalt based adhesives are not recommended for use with this product. 14. When applying DuPont self-adhered flashing products over a cured fluid applied membrane, first apply a wet-bed of DuPont Tyvek Fluid pplied product. For additional guidance, please call Tyvek ( ), visit our website at or consult your local DuPont Tyvek Specialist. opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 4

5 Installation Instructions STEP 1: PREPRTION lean substrate by removing any material that may affect the adhesion of DuPont Tyvek Fluid pplied products, such as frost, oil, grease, mold and efflorescence. Remove all dust, dirt and loose mortar from the substrate using a trowel and brush. DuPont Tyvek Fluid pplied products can be applied to damp masonry. Striking the MU joints flat is recommended. STEP 2: FLSHING 2. Install a DuPont recommended through wall flashing at all necessary locations (e.g. base of the wall, shelf angles, heads of windows, etc.) 2. Install DuPont Tyvek Fluid pplied Flashing or DuPont self-adhered flashing around windows and doors in accordance with the DuPont Tyvek Fluid pplied Flashing - ommercial Installation Guidelines. Visit STEP 4: WETHER RRIER Tyvek Fluid pplied W may be sprayed, brushed or rolled, however application using a pressure roller such as the Graco Pressure Roller, or equivalent, is the preferred method. roller cover with a 1/4 3/8 nap is recommended. When applying by spray, back rolling is also necessary. Tyvek Fluid pplied W needs only to be applied in a single coat at 25 mils thick (yielding approximately 55 sf/gal on MU). Thickness should be controlled by applying the appropriate volume over a marked area and by spot checking with a wet mil gauge. Integrate Tyvek Fluid pplied W with through wall flashing and window/door flashing by overlapping the flashing with Tyvek Fluid pplied W by a minimum of 2. Upon completion, inspect the membrane to ensure that it is continuous and free of any voids or pinholes. See Special onsideration #5, on page 4, for exterior insulation and cladding installation recommendations. STEP 3: WLL/SUSTRTE PREPRTION 3 3. Fill small cracks and voids in masonry with DuPont Tyvek Fluid pplied Flashing and Joint ompound. Large voids should be filled flush with mortar and allowed to cure. 3. Seal around all penetrations using Tyvek Fluid pplied Flashing and Joint ompound or Sealant for Tyvek Fluid pplied System. The fillet bead should extend ½ onto both surfaces (see page 8 for detail). 3. s a best practice DuPont recommends that all embedded masonry anchors be treated by applying a coat of Tyvek Fluid pplied W or Fluid pplied Flashing and Joint ompound around the base of the anchor (see page 9 for additional fastening recommendations). 3D. Treat all non-moving transition joints to beams, columns, and dissimilar materials by applying a 2 wide, 60 mil thick coat of Fluid pplied Flashing and Joint ompound across the joint (grouted joints between similar materials do not need to be treated). Joints up to ¼ can be treated with joint compound alone. Joints from ¼ - ½ should be reinforced with fiberglass mesh tape. lternatively, joints and transitions may be treated using DuPont StraightFlash (see Special onsideration #10, on page 4, for priming requirements). Flashing should extend a minimum of 2 onto each surface (see page 7 for detail). Refer to page 10 for sheathing joint treatment recommendations. 3E. Treat all inside and outside corners by applying a 25 mil thick coat of Tyvek Fluid pplied, 2 onto each adjoining surface. It is recommended that a fillet bead of Tyvek Fluid pplied be applied to inside corners to help ensure continuity. lternately, corners may be treated using DuPont StraightFlash. e sure that DuPont StraighFlash is pressed tightly into the inside corners and is fully adhered to substrate (see Special onsideration #10, on page 4, for priming requirements) E D 2 2 NOTE: s a best practice DuPont recommends that all flashing and detailing work be completed prior to the application of Tyvek Fluid pplied W. Tyvek Fluid pplied products may be overcoated once a touch-free skin has formed. Skin time is 1-2 hrs at 70 F (20 ), 50% RH. opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 5

6 Detailing It is important to maintain the continuity of the weather barrier from top to bottom. The entire wall surface shall be covered, including unconditioned spaces. Special attention should be given to all terminations, transitions, projections and penetrations to ensure a proper drainage plane and a continuous weather barrier is maintained. Foundation. Install a DuPont recommended through wall flashing in accordance with the through wall flashing manufacturer s installation guidelines.. pply any necessary Tyvek Fluid pplied pretreatment, flush with the top of the through wall flashing.. Seal top edge of through wall flashing using DuPont Sealant for Tyvek Fluid pplied System or Tyvek Fluid pplied Flashing and Joint ompound. llow the Tyvek Fluid pplied product to form a touch-free skin, before applying DuPont Tyvek Fluid pplied W. Skin time is 1-2 hrs at 70 F (20 ), 50% RH. D. pply DuPont Tyvek Fluid pplied W onto wall surface at 25 mils thick. Overlap through wall flashing by a minimum of 2. Top of Wall. DuPont Tyvek Fluid pplied W should be installed prior to the installation of the DuPont recommended parapet flashing membrane.. pply a liberal bead of DuPont Sealant for Tyvek Fluid pplied System or Tyvek Fluid pplied Flashing and Joint ompound onto the Tyvek Fluid pplied W at a location that will be approximately 2 up from the bottom edge of the flashing.. Install parapet flashing over the top of wall per parapet flashing manufacturer s guidelines, extending it down over Tyvek Fluid pplied W by at least 4. D. Press flashing into sealant and secure using mechanical fasteners installed through the flashing and sealant bead. NOTE: s soon as practically possible, cap the top of the wall system to reduce the likelihood of water getting behind the facade and into the wall cavity. Transitions 4 D 2 D 1/4 drip edge opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 6

7 METHOD 1* (fluid applied flashing). lean both substrates thoroughly. Remove any material that could negatively affect adhesion.. Fill seam between adjoining substrates flush with the surface using DuPont Tyvek Fluid pplied Flashing and Joint ompound. Joints up to ¼ can be treated with Tyvek Flashing and Joint ompound only. Joints from ¼ - ½ should first be reinforced with fiberglass mesh tape or filled with mortar.. pply a bead Tyvek Fluid pplied Flashing and Joint ompound to both adjoining surfaces and spread material across transition seam to a width of approximately 2 and 60 mils thick. Upon completion, inspect transition treatment for thin spots, gaps or pinholes and repair as necessary. D. llow the Tyvek Fluid pplied product to form a touch-free skin, before applying DuPont Tyvek Fluid pplied W. Skin time is 1-2 hrs, at 70 F (20 ), 50% RH. * For non-moving joints only. METHOD 2* (self-adhered flashing). lean both substrates thoroughly. Remove any material that could negatively affect adhesion.. Prime both substrates using a DuPont recommended primer.. pply a strip of DuPont StraightFlash to the primed substrates. Flashing should extend a minimum of 2 onto each surface. Press StraightFlash firmly onto both surfaces, working it into any irregularities using a J-roller or firm hand pressure. * For non-moving joints only. Transitions to DuPont Tyvek uilding Wrap 2 D opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 7

8 . Install DuPont Tyvek building wrap products per DuPont Installation Guidelines prior to application of DuPont Tyvek Fluid pplied W.. Fasten building wrap to the stud adjoining the transition substrate.. ut DuPont Tyvek building wrap so that approximately 3 will overlap the adjoining substrate. D. Fold back the 3 flap of building wrap and prime adjoining substrate with a DuPont recommended primer. E. Fold building wrap back down over the interface and seal it to the primed substrate using 4 DuPont StraightFlash, overlapping both surfaces evenly by approximately 2. Press DuPont StraightFlash firmly onto any irregular surfaces using a J-roller or firm hand pressure. F. Lastly, apply Tyvek Fluid pplied W onto wall surface, and onto DuPont StraightFlash. Tyvek Fluid pplied W should overlap StraightFlash by a minimum of 2. Do not apply Tyvek Fluid pplied W onto Tyvek building wrap. Upon completion, inspect surface to ensure that Tyvek Fluid pplied W is continuous and free of any voids or pinholes. Penetrations. lean both substrates.. Seal around penetration using DuPont Tyvek Fluid pplied Flashing and Joint ompound or Sealant for Tyvek Fluid pplied System. Upon completion, inspect Tyvek Fluid pplied for gaps or pinholes and repair as necessary.. Tyvek Fluid pplied should extend a minimum of ½ onto both surfaces. llow product to form a touch-free skin, before applying DuPont Tyvek Fluid pplied W. Skin time is 1-2 hrs, at 70 F (20 ), 50% RH. 1/2 3 D E F opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 8

9 rick Ties, ladding Supports, and Furring Strips s a best practice, DuPont recommends that all embedded masonry anchors be treated by applying a coat of DuPont Tyvek Fluid pplied W or DuPont Tyvek Fluid pplied Flashing and Joint ompound around the base of the anchor. When installing mechanically attached supports or furring strips in high performance building envelope designs (building envelope design requirements exceeding STM E 1677, 65 mph equivalent structural load and 15 mph equivalent wind-driven rain water infiltration testing), fasteners shall be sealed by, 1) applying a piece of double sided butyl tape to the back of support bracket at the fastener location, or 2) embedding support bracket into an additional wet bed of a DuPont Tyvek Fluid pplied product, or 3) applying a coat of DuPont Tyvek Fluid pplied product to the screw before installing, or 4) an alternate DuPont approved method. When installing mechanically attached supports or furring strips in building envelope design requirements equivalent to STM E 1677 conditions or less, no pretreatment is necessary. pplication Over Sheathing DuPont Tyvek Fluid pplied W may be installed over exterior gypsum, OS, and plywood sheathing. Sheathing should be clean and free from any materials that could negatively affect adhesion. When installing over sheathing, it is important that all sheathing seams be pretreated using the appropriate joint treatment method (see page 10). ll flashing and detailing should be completed before installation of DuPont Tyvek Fluid pplied W. When applying over exterior gypsum, all cut edges along outside corners and rough openings should first be primed with a recommended primer. Pretreat all inside and outside corners by applying a 25 mil thick coat of Tyvek Fluid pplied, 2 onto each adjoining surface. It is recommended that a fillet bead of Fluid pplied be applied to inside corners to help ensure continuity. lternately, corners may be treated using DuPont StraightFlash. e sure that DuPont StraighFlash is pressed tightly into the inside corners and is fully adhered to substrate (see Special onsideration #10, on page 4, for priming requirements). Tyvek Fluid pplied W may be brushed, rolled or spray applied. However, application using a pressure roller such as Graco Pressure Roller, or equivalent, is the preferred method. roller cover with a 1/4 3/8 nap is recommended. When applying by spray, the surface should be back rolled to insure a pinhole free surface. Fluid pplied W should also be applied in a single coat at 25 mils thick (yielding approximately 65 sf/gal on exterior gypsum). The thickness should be controlled by applying the appropriate volume over a marked area and by spot checking with a wet mil gauge. Upon completion, inspect the membrane to ensure that it is continuous and free of any voids or pinholes. Tyvek Fluid pplied products may be overcoated once a touch-free skin has formed. Exterior insulation and/or cladding may be installed once the membrane has cured sufficiently to resist damage during installation. Skin time is 1-2 hrs, and 25 mil cures in 24 hrs at 70 F (20 ), 50% RH. opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 9

10 Joint Treatment Methods Joint treatment is not necessary for gaps 1/16 wide or less. Method 1 (for gaps up to 1/4 ). pply a bead of DuPont Tyvek Fluid pplied Flashing and Joint compound above and below the sheathing seam.. Smooth joint compound across the joint using a trowel. Joint ompound should extend a minimum of 1 on either side of the joint and be mils thick.. heck joint for thin spots and pinholes, repair as necessary. Method 2 (for gaps up to 1/2 ). Firmly apply self-adhered reinforcing mesh tape.. pply a bead of Tyvek Fluid pplied Flashing and Joint ompound above and below the sheathing seam.. Smooth joint compound across the mesh tape using a trowel. Joint compound should extend a minimum of 1 on either side of the joint and be mils thick. D. heck joint for thin spots and pinholes, repair as necessary. Method 3 (for gaps up to 1 ). pply recommended primer above and below sheathing joint.. enter DuPont StraightFlash over joint and firmly press onto sheathing using a J-roller or firm hand pressure. Method 1 1/16-1/4 Method 2 1/4-1/2 Method 3 1/2-1 Repair Small repairs can be made by coating the damaged area with a layer of Tyvek Fluid pplied product. Larger damaged areas may need to be reinforced using fiberglass mesh or by replacing damaged substrate before reapplying Tyvek Fluid pplied product. Equipment Recommendations pplication using a pressure roller, such as the Graco Pressure Roller, is the preferred method of installation of Tyvek Fluid pplied W. pressure roller can be used in conjunction with a variety of pumps, such as the Graco TexSpray Mark V, TexSpray 7900 HD, GH 733, GH 833 or equivalent. Tyvek Fluid pplied W can be sprayed using a high pressure air-powered, airless sprayer such as the Graco X70 Xtreme Sprayer or equivalent. The recommended tip sizes are minimum hose diameter of 3/8 should be used when spray applying. ll internal filters should be removed from the pump, spray gun, and pressure roller assembly, before applying product. The pump intake screen should be installed when applying product. The condition of the pump, as well as the size, length, and condition of the hoses used can affect the systems performance. The diameter of some hose sections may need to be increased, depending on the pumping distance desired. Refer to pump manufactures representative and guidelines regarding the operation and maintenance of the pump system. Operation of pump equipment can be hazardous. ll manufacturer limitations, warnings, and safety recommendations should be followed. lean Up Uncured material can be cleaned from hands, tools, and equipment by using a citrus based cleaner or standard mineral spirits. ured product can be removed by soaking in a solvent or gel-based paint stripper. Tyvek Fluid pplied W is a moisture cure product and will react with water based products. When applying with a pump system, be sure that the system is completely clean of any incompatible materials before use. If the system is not completely clean or if moisture is present in the system, the product may react and cure in the system. Tyvek Fluid pplied W should not be stored in the pump, hose, gun, or pressure roller. fter application is complete, flush the system with a citrus based cleaner, or standard mineral spirits until the system is clean. Low pressure portions of the pump should be taken apart and cleaned by hand to promote optimal pump performance. efore each use, flush any remaining solvent out of the system before applying Tyvek Fluid pplied W to the wall. Refer to pump manufacturer instructions for additional cleaning and storage recommendations. opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 10

11 Health and Safety Tyvek Fluid pplied System products contain calcium carbonate, vinyl trimethoxysilane and diaminopropyl trimethoxysilane. Vapor harmful if using spray application. Use in a well ventilated area. Use a NIOSH approved respirator. If vapors are inhaled, immediately remove from exposure and contact a physician. void contact with eyes and skin. Protective eye wear and gloves are recommended. Refer to the MSDS for complete health and safety information. Visit Tyvek Fluid pplied website at Disposal Dispose of any residual fluid applied material or fluid applied coated debris in accordance with applicable federal, state, and local government regulations. Facade/Exterior onsiderations NOTE: Refer to Special onsideration #5, on page 4, for exterior insulation and cladding installation recommendations. rick The rick Industry ssociation recommends a 1 air-space in front of wood stud construction and a 2 air-space in front of steel stud construction. onsistent with these requirements and recommendations, Tyvek Fluid pplied W shall be separated from the brick veneer by a minimum 1 air-space. Window and door flashing and through wall flashing shall be integrated with the DuPont Tyvek Fluid pplied W in accordance with these installation guides. For maximum moisture management and drying of the wall system, the airspace in front of the Fluid pplied W shall be vented to the exterior at the top and bottom of the wall. Stucco When stucco is installed over wood-based sheathing the 2012 International uilding ode (Section ) requires a water-resistive vapor-permeable barrier with a performance at least equivalent to two layers of Grade D paper or a layer of weather barrier which is separated from the stucco by an intervening layer. When the DuPont Tyvek Fluid pplied W is used behind stucco, it should be separated from the stucco by an intervening layer per section of the 2012 International uilding ode. DuPont Tyvek Fluid pplied W should be installed as the first air and water barrier directly over the face of the substrate, and should be integrated with the window and door flashings, the weep screed at the bottom of the wall and any through wall flashings or expansion joints. Lath shall be installed over the intervening layer (second layer) in accordance with STM Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland ement-ased Plaster and applicable codes. Metal Panel When used with DuPont Tyvek Fluid pplied W, metal panel cladding systems shall be installed according to manufacturer s instructions and industry standards. Window and door flashing and through wall flashing shall be integrated with the Tyvek Fluid pplied W. Stone Veneer The 2009 International uilding ode (Section1405.7) requires two layers of a water resistive barrier behind stone veneers over framed construction. When used behind stone veneer, DuPont Tyvek Fluid pplied W shall be installed in a similar manner as it is behind stucco. When installed over wood frame construction, DuPont Tyvek Fluid pplied W should be separated from the stone and mortar by an intervening layer (second layer) of a DuPont Tyvek building wrap, a layer of grade D building paper, felt, rigid foam board or the paper backing of paper-backed lath. DuPont Tyvek Fluid pplied W should be installed as the first air and water barrier layer directly over the face of the substrate, and should be integrated with the window and door flashings, the weep screeds at the bottom of the wall and any through wall flashings or expansion joints. Lath shall be installed over the intervening layer (second layer) in accordance with STM Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland ement-ased Plaster and applicable codes. Wood Siding When used with DuPont Tyvek Fluid pplied W, and wood siding shall be installed according to manufacturer s instructions, industry standards and applicable codes. s recommended by the Western Red edar Lumber ssociation and U. S. Forest Product Laboratory, wood siding should be primed on all six sides before installation. In high exposure installations, enhanced drainage and water management may be provided by using DuPont Tyvek ommercialwrap D or by creating rainscreen cladding with a larger airspace behind the siding using furring strips. opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 11

12 Fiber ement Siding When used with DuPont Tyvek Fluid pplied W, fiber cement siding shall be installed according to manufacturer s instructions and industry standards. In high exposure installations, enhanced drainage and water management may be provided by using DuPont Tyvek ommercialwrap D or by creating rainscreen cladding with a larger airspace behind the siding using furring strips. Exterior Insulation Exterior Insulation should be installed after the appropriate flashing materials have been installed and DuPont Tyvek Fluid pplied W has been applied and properly integrated with flashing. Exterior insulation shall be installed in accordance with manufacture s guidelines and industry standards. The level of performance of exterior insulation (continuous insulation) is dependent upon proper installation and continuity limitations due to the design of the building envelope. opyright 2014 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 09/14 12

13 Technical Specifications DuPont Tyvek Fluid pplied products are formulated to include elastomeric polymers that cure to continuous, fully-adhered, tough, durable membranes. dditives have been incorporated to provide ultraviolet light resistance. DuPont requires that the DuPont Tyvek Fluid pplied W, DuPont Tyvek Fluid pplied Flashing and Joint Treatment ompound, and DuPont Tyvek Fluid pplied rush Formulation are to be covered within 9 months of installation. DuPont FlexWrap NF and StraightFlash flashing products are made from a synthetic rubber adhesive and a top sheet of flash spunbonded high density polyethylene fibers. dditives have been incorporated into these materials to help provide UV light resistance. DuPont requires that DuPont FlexWrap NF and StraightFlash be covered within 9 months of installation. Warning DuPont Tyvek Fluid pplied products should be used only as directed. void contact with eyes and skin, gloves are recommended. First id: Eye & Skin ontact; Wash thoroughly with water. If irritation persists, contact a physician. KEEP OUT OF REH OF HILDREN. DuPont FlexWrap NF and DuPont StraightFlash products and their release paper are slippery and should not be walked on. Remove release paper from work area immediately. DuPont FlexWrap NF and DuPont StraightFlash will melt at temperatures greater than 250 F (121 ). DuPont self-adhered flashing products are combustible and should be protected from flame and other high heat sources. If burning occurs, ignited droplets may fall away from the point of ignition. For more information, call Tyvek. Note When installed in conjunction with other building materials, DuPont Tyvek Fluid pplied products must be properly integrated so that water is diverted to the exterior of the wall system. DuPont Tyvek Fluid pplied W is a secondary weather barrier. The outer facade is the primary barrier. Do not install on a wall that does not feature a continuous path for moisture drainage. ny standing water must be allowed to drain off the membrane. You must follow facade manufacturer s installation and maintenance requirements for all facade systems in order to maintain water holdout properties and ensure performance of Tyvek Fluid pplied W. Use of additives, coatings or cleansers on or in the facade system may impact the performance of Tyvek Fluid pplied products. Tyvek Fluid pplied W is to be used as outlined in this installation guideline. Tyvek Fluid pplied flashing products and DuPont self-adhered flashing products should only be used to seal penetrations and flash openings in houses or buildings. DuPont Tyvek Fluid pplied Products must not come in contact with building wrap products due to potential impact on performance properties. Tyvek Fluid pplied products are not to be used in roofing applications. For superior protection against bulk water penetration, DuPont suggests a system combining a quality exterior facade, a good secondary weather barrier and exterior sheathing, high quality windows and doors, and appropriate flashing materials paying attention to proper installation of each component. Depending on job site conditions, it is possible that stains may appear, but will not alter performance of the fluid applied product. DuPont believes this information to be reliable and accurate. The information may be subject to revision as additional experience and knowledge is gained. It is the user s responsibility to determine the proper construction materials needed. For complete warranty information please call Tyvek. This information is not intended to be used by others for advertising, promotion, or other publication for commercial purposes. For more information about DuPont Weatherization Systems, please call Tyvek or visit us at opyright 2014 E.I. du Pont de Nemours and ompany. ll rights reserved. The DuPont Oval Logo, DuPont, Tyvek, ommercialwrap, FlexWrap, and StraightFlash are registered trademarks or trademarks of DuPont or its affiliates. ll rights reserved. K /14

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines Installation Instructions for Integral Flanged Door FTER Water-Resistive Barrier (WRB) is Installed DuPont Flashing Systems Installation Guidelines INSTLLTION INSTRUCTIONS FOR INTEGRL FLNGED DOOR FTER

More information

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines Installation Instructions for Windows and Doors EFORE Water-Resistive arrier (WR) is Installed DuPont Flashing Systems Installation Guidelines INSTLLTION INSTRUTIONS FOR WINDOWS ND DOORS EFORE WTER-RESISTIVE

More information

DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines

DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines HELPING YOU GET THE JOB DONE RIGHT FOR BUILDINGS LESS THAN 5

More information

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Residential Single Family Houses Using Vinyl, Brick and Stone Claddings VERSION 10/13

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Residential Single Family Houses Using Vinyl, Brick and Stone Claddings VERSION 10/13 DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Residential Single Family Houses Using Vinyl, Brick and Stone Claddings VERSION 10/13 Table of Contents Applicable Products... 2 Recommended

More information

Avoiding Air Barrier Pitfalls

Avoiding Air Barrier Pitfalls Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great

More information

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS AC TOPSEAL SELF-ADHERED, GRANULAR SURFACED, SINGLE PLY, LOW SLOPE ROLLED ROOFING 3 X 33.3 = 100 SQ. FT. 10 YEAR MATERIAL LIMITED WARRANTY For Use on Porches / Sheds / Utility Buildings / Accessory Buildings

More information

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction

More information

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within

More information

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration DS497 SECTION ONE A. Objective The objective of this guide is to provide owners and general contractors/construction

More information

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings VERSION 1/16 FOR SINGLE FAMILY HOMES AND LOW RISE MULTI-FAMILY BUILDINGS LESS THAN 4 STORIES Tyvek

More information

The science of better-performing buildings.

The science of better-performing buildings. The science of better-performing buildings. Small detail. Big impact. Of the hundreds of decisions you and your team make every day, choosing a weather barrier system containing either DuPont Tyvek CommercialWrap

More information

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide GeneralShale.com OLD BRICK ORIGINALS THIN BRICK VENEER Page 2 INTRODUCTION Check local building codes for proper installation guidelines

More information

GreenGuard Housewrap Installation Guide

GreenGuard Housewrap Installation Guide 000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be

More information

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read

More information

K2 STONE NATURAL VENEER

K2 STONE NATURAL VENEER INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin

More information

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar VERSION 1/16 FOR SINGLE FAMILY HOMES AND LOW-RISE MULTI-FAMILY BUILDINGS

More information

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1 Building Science Bulletin DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1 and IECC Air Leakage Requirements When Tested in Accordance with ASTM E2357

More information

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS Introduction This inspection guide is organized to follow the EIF System's Installation Guide.

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

Colorado State University. Durrell Center Roof Repair

Colorado State University. Durrell Center Roof Repair Colorado State University Durrell Center Roof Repair SPECIFICATION: POLYURETHANE FOAM ROOFING l.0 GENERAL REQUIREMENTS The successful application of a polyurethane foam roofing system is dependent upon

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions

More information

Tundra Series Windows January 2016

Tundra Series Windows January 2016 Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit. Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden

More information

How to repair your existing low slope flat roof.

How to repair your existing low slope flat roof. How to repair your existing low slope flat roof. Recycled Rubber Roofing is not a "Roof Coating." It is a liquid emulsion used as the underlayment of a new or retrofit, built-up roofing system. One of

More information

DELTA Premium Moisture Management Systems for Foundations.

DELTA Premium Moisture Management Systems for Foundations. DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.

More information

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC

More information

2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS

2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS 2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS The LOGIX wall assembly has no need for an additional vapor barrier, the solid concrete core covered with the low permeance EPS (Type II) foam

More information

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick Photo courtesy of Delta Stone, Heber City, UT Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick THIN VENEER INSTALLATION SYSTEMS PREMIUM BONDING MORTARS Premium PCL Stone

More information

Building Envelope. Moisture Drainage & Ventilation Products from Keene Building Products. www.keenebuilding.com

Building Envelope. Moisture Drainage & Ventilation Products from Keene Building Products. www.keenebuilding.com Building Envelope Moisture Drainage & Ventilation Products from Keene Building Products Driwall Rainscreen CAV-AIR-ATOR KeeneStone Cut KeedeLath Driwall Mortar Deflection Driwall Weep Screed Driwall Membrane

More information

Residential Roofing Guide

Residential Roofing Guide Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

Shower Walls and Tub Surrounds

Shower Walls and Tub Surrounds Reverso en español TEC Skill Set How-To Project Guide Shower Walls and Tub Surrounds 3 Steps to a Beautiful Tile Surface! 1. Prepare the surface 2. Set the tile 3. Grout and caulk H.B. Fuller Construction

More information

DUPONT TYVEK BUILDING WRAPS VS. ZIP SYSTEM WALL SHEATHING

DUPONT TYVEK BUILDING WRAPS VS. ZIP SYSTEM WALL SHEATHING TECH TALK DUPONT TYVEK BUILDING WRAPS VS. ZIP SYSTEM WALL SHEATHING DuPont offers six different DuPont Tyvek building wraps intended for use on a wide range of buildings from single family homes to high

More information

WELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry

WELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry WELCOME Recommended Window 1.5 credits Minnesota Department of Labor and Industry In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized

More information

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product

More information

Thin Veneer Stone Installation Guide

Thin Veneer Stone Installation Guide Thin Veneer Stone Installation Guide Complete step by step How-to guide for installing Thin Veneer Stone. Important: From pallet to pallet of natural thin veneer stone, as with any natural stone product,

More information

Manufactured Stone Veneer Installation Instructions

Manufactured Stone Veneer Installation Instructions Manufactured Stone Veneer Installation Instructions Published: 8/14/2008 Revised: 6/25/2010 Table of Contents PART 1 -- INTRODUCTION PART 2 -- MATERIAL REQUIREMENTS PART 3 EXECUTION REQUIREMENTS PART 4

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised Page 1 of 6 instructions VC 104+ Rigid Grade / VC 104+ Rigid Grade Imagine / (for the rest of this document referred to as VC 104) can be applied to new and used trucks and trailers with painted rigid

More information

Natural Thin Stone Veneer

Natural Thin Stone Veneer Natural Thin Stone Veneer Until recently, if a project called for the natural look of stone but could not support its weight or thickness, the options were limited to manufactured imitation stone. More

More information

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling. i This instruction sheet describes the proper methods for installing Eucatex decorative wall paneling. Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in

More information

INSTALLATION INSTRUCTIONS for Vinyl Patio Doors with Integral Nailing Fin (JII006)

INSTALLATION INSTRUCTIONS for Vinyl Patio Doors with Integral Nailing Fin (JII006) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl Patio Doors with nailing fin. Any local building code requirements supersede the recommended

More information

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation

More information

SEAMS SEAMING USING SEAM TAPE

SEAMS SEAMING USING SEAM TAPE SEAMING USING SEAM TAPE SEAMS The membrane should be positioned so that the width of the seam is 3. Remove excess chalk from a chalk line by snapping the line into the air and then chalk a line one-quarter

More information

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam

More information

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders

More information

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES REFLECTICLEAN ACRYLIC/URETHANE Elastomeric Roofing Systems, Inc 6900 Bleck Dr. Rockford, MN 55373 800.403.7747 -or- 763.565.6900 fax: 763.565.6901 email:

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

Section 04810 EXTERIOR STONE VENEER Full Mortar

Section 04810 EXTERIOR STONE VENEER Full Mortar Full Mortar PART 1 GENERAL 1.1 SUMMARY A. Section includes: 1. Portland cement mortar bed 2. Stone Veneer 3. Expansion and control joints. 4. Portland cement and hydraulic mortar and grout. 5. Sealer and

More information

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.

More information

Standard Method for Sampling and Analysis of. of Chlorine Containing Bleaches. Soap Products

Standard Method for Sampling and Analysis of. of Chlorine Containing Bleaches. Soap Products GUIDE SPECIFICATION FOR GENERAL CLEANING AND REMOVAL OF MOLD AND MILDEW ON EXTERIOR INSULATED AND FINISH SYSTEMS AND STUCCO DIVISION 07240 and DIVISION 09240 8/05 PART I: GENERAL 1.01 DESCRIPTION AND SCOPE

More information

BENTLEY ELEMENTS COLLECTION LVT

BENTLEY ELEMENTS COLLECTION LVT This document refers to the following products: Product Size Installation direction Seams treatment Elements Tiles See specifications 90 None Elements Planks See specifications Stair Step None Note: This

More information

application instructions

application instructions application instructions ARCHITECTURAL COLLECTION PRIMED BOLD PROFILE 120 SERIES LAP SIDING (D5, T4, D8, T5, Q4) General At the time of manufacture, siding meets or exceeds the performance standards set

More information

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit. Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden

More information

Barewood Octagon and Elongated Windows Installation Instructions

Barewood Octagon and Elongated Windows Installation Instructions Step-by-step instructions to a beautiful window. Measuring and Installation of your new window from Century Specialty Windows couldn't be easier with our step-by-step instructions. Quality, function and

More information

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements

More information

RECOATING AND RENEWING SPF ROOFING SYSTEMS

RECOATING AND RENEWING SPF ROOFING SYSTEMS RECOATING AND RENEWING SPF ROOFING SYSTEMS Procedures, Regional Differences and type of coating systems Bruce Schenke Premium Spray Products REASONS TO RECOAT/RENEW Add a new coating layer to renew the

More information

Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group

Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group Since water intrusion is among the most damaging problems

More information

T R A N S F E R A B L E F U L LY

T R A N S F E R A B L E F U L LY HSTOPS A WALL OF WATER 22 FT. HIG! F U L LY T R A N S F E R A B L E RESISTS10 PSI ! 1 F U L LY T R A N S F E R A B L E HSTOPS A WALL OF WATER 22 FT. HIG RESISTS10 PSI Guaranteed To Stop Water Even Under

More information

Comment Form on Proposed Gut Rehabilitation Alternatives

Comment Form on Proposed Gut Rehabilitation Alternatives Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to energystarhomes@energystar.gov by October 10 th, 2012 with the subject line

More information

2015 DuROCK Alfacing International Limited

2015 DuROCK Alfacing International Limited SEPTEMBER 2015 DuROCK DEFS Direct-Applied Exterior Finish System MANUFACTURER S IFICATION 09 25 15 Part 1 GENERAL 1.1 RELATED SECTIONS.1 Specification 03 30 00 Cast-in-Place Concrete.2 Specification 04

More information

Resurfacing Concrete. Page 1 of 5

Resurfacing Concrete. Page 1 of 5 Resurfacing Concrete Materials List QUIKRETE Concrete Resurfacer (No. 1131) (see calculator on page 5 for quantity needed) QUIKRETE Concrete and Stucco Wash (No. 8601) QUIKRETE Concrete Sealer (No. 8800)

More information

SC2000 CEMENT BONDING PROCEDURES

SC2000 CEMENT BONDING PROCEDURES Pg.1 SC2000 CEMENT BONDING PROCEDURES Widely recognized as the world s finest cold vulcanizing cement REMA SC2000 is the solution to your industrial bonding problems. By using REMA UTR20 hardener with

More information

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs CertainTeed Self-Adhering Roof Systems for Low Slope Residential Roofs Goes down fast. Stays on strong. Flintlastic SA performs in all the right ways. What s more important to you? Speed of installation,

More information

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)

More information

The existing roof angle change terminations and flashings when sound and intact can be reused.

The existing roof angle change terminations and flashings when sound and intact can be reused. January 2, 2015 Summary Specification Re-Skinning an Existing Roof Maintenance and Repair Warranty Upgrade for Up to 30 Years Re-Skinning Over an Existing Roof with a New C-EPDM Membrane Using The Existing

More information

September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections

More information

Basement Window Installation Guide Hopper and Sliding

Basement Window Installation Guide Hopper and Sliding Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

How to Install GoBoard:

How to Install GoBoard: How to Install GoBoard: A Step-by-Step Guide Durable, Ultra-Lightweight, Waterproof Tile Backer Board Introducing GoBoard Every tiling project requires a durable, waterproof surface under the tile, called

More information

WATERPROOFING OF WET ROOMS

WATERPROOFING OF WET ROOMS WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof

More information

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials SECTION 03 92 50 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings,

More information

Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES

Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES ARCHITECTURAL SPECIFICATIONS / CAD MODELS With more than 40 years of manufacturing high quality, innovative building products in the commercial and residential markets, Custom Building Products TVISTM

More information

BLACK JACK ALL WEATHER ROOF COATING

BLACK JACK ALL WEATHER ROOF COATING PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.

More information

GigaCrete Specification PlasterMax

GigaCrete Specification PlasterMax GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application

More information

PANELIZED HOME INSTALLATION GUIDELINE

PANELIZED HOME INSTALLATION GUIDELINE PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.

More information

Backstop NT. Backstop NT Specifications DS180. A High Performance, Polymer-Based, Noncementitious Water-Resistive Membrane and Air Barrier

Backstop NT. Backstop NT Specifications DS180. A High Performance, Polymer-Based, Noncementitious Water-Resistive Membrane and Air Barrier Backstop NT A High Performance, Polymer-Based, Noncementitious Water-Resistive Membrane and Air Barrier Backstop NT Specifications DRYVIT SYSTEMS, INC. MANUFACTURER S SPECIFICATION CSI MASTERFORMAT SECTIONS

More information

The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco

The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco Disclaimer: This guide contains general information on stucco installation and related materials. It is provided as a guide only and is

More information

Clad Direct Glaze Window Installation Instructions

Clad Direct Glaze Window Installation Instructions Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully

More information

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00 THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00 THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3758 Reissued 04/2016 This report is subject to renewal 04/2017. DIVISION: 07 00 00 THERMAL

More information

How To Repair A Boat Landing Deck With A Boat Bed

How To Repair A Boat Landing Deck With A Boat Bed RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for vinyl windows without a nailing fin (including finless, flush fin and flange). Read these instructions

More information

RTV162. Electronic Grade Silicone Adhesive Sealant

RTV162. Electronic Grade Silicone Adhesive Sealant RTV162 Product Description Electronic Grade Silicone Adhesive Sealant RTV162 adhesive sealant from GE Silicones is one-component, readyto-use electronic grade silicone sealant. It cures to a tough, resilient

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nail fin. Not all window types may be installed into every wall

More information

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill ENERGY STAR Qualified New Homes Thermal Enclosure Checklist & Water Management Checklist Eli Caudill ENERGY STAR Version 3 Tighter Standards Whole Home Approach Better, More Sustainable Construction Surpasses

More information

Composite Stone Veneer

Composite Stone Veneer Composite Stone Veneer Installation Guide Ver 1 Jun 2015 www.compstone.com Composite Stone Veneer Installation Guide Contents Introduction & Overview 3 Required Tools 4 Optional Tools 4 Attachment Guidelines:

More information

Building Owners Guide to a Duro-Last System!

Building Owners Guide to a Duro-Last System! Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof

More information

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced

More information

Renovating Your Basement

Renovating Your Basement building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:

More information

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION 07560 BUR BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION PART 1: GENERAL 1.01 SCOPE: To extend the useful service life of the aged or new asphalt built-up roof system and to reduce cooling

More information

Product Information/Specifications

Product Information/Specifications BARN & FENCE PAINT NO. 25 BARN RED Smooth or rough sawn exterior vertical wood surfaces such as plywood, fences, shingles, shakes, siding. laminates, masonry and stucco surfaces. AVAILABLE IN: Gallon Only

More information

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side

More information

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry

More information

ITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING

ITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier

More information

Important Information for Installer & Homeowner

Important Information for Installer & Homeowner Important Information for Installer & Homeowner Homeowner: Please keep this information for your records, do not discard! Installation Instructions for Wood Frame Construction Replacement (See other side

More information

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS 09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS PDS SE-160 01-2006 1. PRODUCT NAME SE-160 Clear Surface Coating (water-based copolymer) Specialty Elastomeric Topcoat 2. MANUFACTURER

More information