Product Guide Specification
|
|
|
- Darrell Grant
- 9 years ago
- Views:
Transcription
1 Covermaster Inc. April Westmore Drive, Unit 11D Rexdale, Ontario M9V 5C3 Toll Free (800) Phone (416) Fax (416) Website Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described in The Project Resource Manual CSI Manual of Practice, Fifth Edition. The section must be carefully reviewed and edited by the Architect to meet the requirements of the project and local building code. Coordinate this section with other specification sections and the Drawings. Delete all Specifier Notes after editing this section. Section numbers are from MasterFormat 1995 Edition, with numbers from MasterFormat 2004 Edition in parentheses. Delete version not required. SECTION ( ) PROTECTIVE GYMNASIUM FLOOR COVERS Specifier Notes: This section covers Covermaster Inc. Ultima 5000, Ultima 4000, and Ultima 3000 protective gymnasium floor covers; Ultima Series Covermate II cover handling system; and optional accessories. Consult Covermaster Inc. for assistance in editing this section for the specific application. PART 1 GENERAL 1.1 SECTION INCLUDES Specifier Notes: Edit the following list as required for the project. A. Protective gymnasium floor covers. B. Cover handling system. C. Accessories: 1. Power winder. 2. Dual-brush system. Protective Gymnasium Floor Covers ( ) - 1
2 3. Walk-behind tape dispenser. 4. Seaming tape. 5. Protective gymnasium floor cover cleaner. 6. Storage cover. 1.2 RELATED SECTIONS Specifier Notes: Edit the following list of related sections as required for the project. List other sections with work directly related to this section. A. Section ( ) Wood Athletic Flooring. 1.3 REFERENCES Specifier Notes: List standards referenced in this section, complete with designations and titles. This article does not require compliance with standards, but is merely a listing of those used. A. ASTM D 751 Standard Test Methods for Coated Fabrics. B. ASTM D 1894 Standard Test Method for Static and Kinetic Coefficients of Friction of Plastic Film and Sheeting. C. Fed. Std Strength and Elongation, Breaking of Woven Cloth; Grab Method. D. Fed. Std Strength of Cloth, Tearing: Tongue Method. E. NFPA 701 Standard Methods of Fire Tests for Flame Propagation of Textiles and Films. F. UL 214 Tests for Flame Propagation of Fabrics and Films. 1.4 SUBMITTALS A. Comply with Section ( ) Submittal Procedures. B. Product Data: Submit manufacturer s product data. C. Samples: Submit manufacturer s samples of protective gymnasium floor covers, minimum 6 inches by 6 inches. D. Manufacturer s Certification: Submit manufacturer s certification that materials comply with specified requirements and are suitable for intended application. E. Operation and Maintenance Manual: Submit manufacturer s operation and maintenance manual, including the following: 1. Assembly, operation, maintenance, adjustment, and cleaning instructions. 2. Parts list. F. Warranty: Submit manufacturer s standard warranty. 1.5 QUALITY ASSURANCE Protective Gymnasium Floor Covers ( ) - 2
3 A. Manufacturer s Qualifications: Manufacturer regularly engaged, for preceding 10 years, in manufacture of protective gymnasium floor covers and cover handling systems. 1.6 DELIVERY, STORAGE, AND HANDLING A. Delivery: Deliver materials to site in manufacturer s original, unopened containers and packaging, with labels clearly identifying product name and manufacturer. B. Storage: 1. Store materials in accordance with manufacturer s instructions. Specifier Notes: Edit the following sentence as required. 2. Store protective gymnasium floor covers and cover handling system [in clean, dry area indoors] [as indicated on the Drawings] [at location directed by Owner]. C. Handling: Protect materials and finish during handling to prevent damage. 1.7 WARRANTY A. Warranty Period: Specifier Notes: Include warranty period for the specified materials. Delete materials not specified. 1. Protective Gymnasium Floor Covers: a. Ultima 5000 : 20 years. b. Ultima 4000 : 17 years. c. Ultima 3000 : 12 years. 2. Cover Handling System Ultima Series Covermate II : 20 years. 3. Power Winder Powermate : Lifetime. 4. Dual-Brush System: 5 years. PART 2 PRODUCTS 2.1 MANUFACTURER A. Covermaster Inc., 100 Westmore Drive, Unit 11D, Rexdale, Ontario M9V 5C3. Toll Free (800) Phone (416) Fax (416) Website E- mail [email protected]. 2.2 PROTECTIVE GYMNASIUM FLOOR COVERS Specifier Notes: Specify Ultima 5000, Ultima 4000, or Ultima 3000 protective gymnasium floor covers. Delete floor covers not required. Consult Covermaster Inc. for more information. A. Protective Gymnasium Floor Covers: Ultima Material Properties: Protective Gymnasium Floor Covers ( ) - 3
4 a. Surface Finish: Safety, slip-resistant, ripple pattern. b. Surface Treatment: Cover-Guard treated to resist odors and germs. Rot and mildew resistant. c. Fabric Core: Single layer, woven polyester. d. Filament Size: 1,500 denier. e. Weave Count: 30 by 30. f. Coating: PVC, knife/spread-coating process. g. Total Cover Thickness: 34 mils. h. Weight: 1) Outer Vinyl Wear Coating, Top and Bottom: 11 ounces per square yard on each side. 2) Inner Fabric Core: 10 ounces per square yard. 3) Total Cover: 32 ounces per square yard. i. Can be used with either side up. 2. Mechanical Properties: a. Slip-Resistant Surface, Coefficient of Friction, ASTM D 1894: ADA compliant. b. Tensile Strength, Fed. Std : 850 by 800 pounds. c. Tear Strength, Fed Std : 200 by 180 pounds. 3. Fire Resistance Compliance: a. UL 214. b. NFPA 701, large-scale test. c. California Fire Marshall. d. Connecticut Fire Marshall: Class 1 rating. e. State of New York: Class A rating. 4. Construction: a. Section Length: Match length of floor. b. Section Width: 10 feet. c. Seams: Thermally welded. d. Lap Weld: Minimum 1 inch. 5. Colors: Specifier Notes: Specify the color for each side of the protective gymnasium floor covers. The following are the three standard, dual-color combinations. Delete colors not required. a. Dual-Color Combinations: [Neutrino on 1 side, royal blue on other side] [Neutrino on 1 side, dark grey on other side] [Neutrino on 1 side, hunter green on other side]. Specifier Notes: The following are optional colors for single-color and dual-color combinations. These optional colors are subject to minimum quantities. In addition to these colors, a custom-color matching service to coordinate colors with any decor is available. Consult Covermaster Inc. for more information. b. Single-Color and Dual-Color Combinations: [Single color both sides] [Dual-color combination, 1 color each side]; [burgundy] [dark grey] [deep red] [hunter green] [kelly green] [light grey] [navy blue] [orange] [royal blue] [yellow]. B. Protective Gymnasium Floor Covers: Ultima Material Properties: a. Surface Finish: Safety, slip-resistant, diamond-tread-plate pattern. b. Surface Treatment: Cover-Guard treated to resist odors and germs. Rot and mildew resistant. Protective Gymnasium Floor Covers ( ) - 4
5 c. Fabric Core: Single layer, woven polyester. d. Weave Count: 19 by 19. e. Coating: PVC, knife/spread-coating process. f. Weight: 1) Outer Vinyl Wear Coating, Top and Bottom: ounces per square yard on each side. 2) Inner Fabric Core: 5.30 ounces per square yard. 3) Total Cover: 26 ounces per square yard. g. Can be used with either side up. 2. Mechanical Properties: a. Slip-Resistant Surface, Coefficient of Friction, ASTM D 1894: ADA compliant. b. Tensile Strength, Fed. Std : 440 pounds. c. Tear Strength, Fed. Std : 120 pounds. d. Adhesion, ASTM D 751: 35 pounds per inch. e. Hydrostatic Resistance, ASTM D 751: 430 pounds per inch. 3. Fire Resistance Compliance: a. UL 214. b. NFPA 701, large-scale test. c. California Fire Marshall. d. Connecticut Fire Marshall: Class 1 rating. e. State of New York: Class A rating. 4. Construction: a. Section Length: Match length of floor. b. Section Width: 10 feet. c. Seams: Thermally welded. d. Lap Weld: Minimum 1 inch. 5. Colors: Specifier Notes: Specify the color for each side of the protective gymnasium floor covers. The following are the three standard, dual-color combinations. Delete colors not required. a. Dual-Color Combinations: [Desert sand on 1 side, royal blue on other side] [Desert sand on 1 side, dark grey on other side] [Desert sand on 1 side, hunter green on other side]. Specifier Notes: The following are optional colors for single-color and dual-color combinations. These optional colors are subject to minimum quantities. In addition to these colors, a custom-color matching service to coordinate colors with any decor is available. Consult Covermaster Inc. for more information. b. Single-Color and Dual-Color Combinations: [Single color both sides] [Dual-color combination, 1 color each side]; [burgundy] [dark grey] [deep red] [hunter green] [kelly green] [light grey] [navy blue] [orange] [royal blue] [yellow]. C. Protective Gymnasium Floor Covers: Ultima Material Properties: a. Surface Finish: Safety, slip-resistant, holographic-cube pattern. b. Surface Treatment: Cover-Guard treated to resist odors and germs. Rot and mildew resistant. c. Fabric Core: Single layer, woven polyester. d. Weave Count: 18 by 18. Protective Gymnasium Floor Covers ( ) - 5
6 e. Coating: PVC, knife/spread-coating process. f. Weight: 1) Outer Vinyl Wear Coating, Top and Bottom: 8.5 ounces per square yard on each side. 2) Inner Fabric Core: 4.0 ounces per square yard. 3) Total Cover: 21 ounces per square yard. g. Can be used with either side up. 2. Mechanical Properties: a. Slip-Resistant Surface, Coefficient of Friction, ASTM D 1894: ADA compliant. b. Tensile Strength, Fed. Std : 375 pounds. c. Tear Strength, Fed. Std : 90 pounds. d. Adhesion, ASTM D 751: 35 pounds per inch. e. Hydrostatic Resistance, ASTM D 751: 430 pounds per inch. 3. Fire Resistance Compliance: a. UL 214. b. NFPA 701, large-scale test. c. California Fire Marshall. d. Connecticut Fire Marshall: Class 1 rating. e. State of New York: Class A rating. 4. Construction: a. Section Length: Match length of floor. b. Section Width: 10 feet. c. Seams: Thermally welded. d. Lap Weld: Minimum 1 inch. 5. Dual-Color Combination: Twilight gold on 1 side, midnight blue on other side. 2.3 COVER HANDLING SYSTEM Specifier Notes: Consult Covermaster Inc. for custom-designed cover handling system. A. Cover Handling System: Ultima Series Covermate II. 1. Size: a. Width: 1) Outriggers Retracted: 34 inches. 2) Outriggers Extended: 57-1/2 inches. b. Length: Specifier Notes: Specify height of six-, eight-, or 10-roller model of cover handling system. c. Height: 1) Six-Roller Model: ) Eight-Roller Model: ) Ten-Roller Model: Frame: 1-1/2-inch and 2-inch rectangular-tubular frame. 3. Frame Finish: a. Powder coat. b. Color: Silver. 4. Outriggers: a. Provides stability against tipping. b. Retractable. Protective Gymnasium Floor Covers ( ) - 6
7 c. Two adjustable, swivel casters on each outrigger. d. Locking pins secure outriggers in extended or retracted positions. e. Color: Safety orange. 5. Pressure Floor Locks: a. Two floor-locking brakes, 1 at each end of unit. b. Foot operated. c. Bolted to frame. d. Locks cover handling system to floor. 6. Casters: a. Six Colson ball-bearing casters. b. Non-marking Santoprene SofTreads treads. c. One of 3 casters at each end is offset to spread load over larger area and to better protect floor. d. Diameter: 6 inches. e. Tread Width: 2 inches. f. Tread Thickness: 3/4 inch. 7. Roller Collars: a. On each end of each roller. b. Holds roller captive. c. No exposed pins. Prevents sideways movement of roller. d. Eliminates finger pinch points. e. Color: Bright yellow. 8. Roller-Bearing Brackets: a. Polycarbonate brackets with Delrin roller bearings. b. Mounted with 1/8-inch-thick shock-absorbing rubber pads. c. Safety bolt on each roller-bearing bracket holds roller captive to prevent roller popups. 9. Rollers: a. Flo-Coat galvanized steel with clear topcoat. b. Diameter: 2-1/2 inches. 10. Fastening Clips: a. Four push-on clips for each roller. b. Extruded, flexible plastic. c. Color: Orange. 11. Loading Covers on Rollers: Two 1-piece Lexan polycarbonate hand cranks. 12. Certified Load Capacity: 5,400 pounds. 13. Assembly: Field assembled. Include instruction manual. 2.4 ACCESSORIES Specifier Notes: Specify optional accessories required. Delete accessories not required. Consult Covermaster Inc. for more information. A. Power Winder: Powermate. 1. Noise Rating, Emission at Workplace: 83 db. 2. Motor: Specifier Notes: Specify 110 V or 220 V. a. [110 V] [220 V], 1200 W, 50 to 60 Hz. Protective Gymnasium Floor Covers ( ) - 7
8 b. Forward/reverse switch. c. Thermal overload protection. d. Automatic disconnect with reset button. 3. Gear Head: Automatic infinitely variable rotation 35 to 27 rpm. 4. Gear: Plastic-coated aluminum. 5. Storage: Storage/carrying case. 6. Housing: a. Glass-fiber reinforced. b. Color: Bright yellow. B. Dual-Brush System: Ultima Series Coverclean. 1. Mounting: a. Quick connect/disconnect. b. 1-5/8-inch, 14-gauge drawn channel. c. Mounts on both sides of system. 2. Brush Angle: Brush mounted at 35-degree angle to match path of cover travel at each roller height. 3. Brush Heads: Dual-opposing heads sweep debris and dust from both sides of cover during wind-up. 4. Bristles: a. Two rows of 3-inch bristles. b. Black, Styrene-Fiber Bristle Row: Fine sweeping. c. Red, Polystyrene-Fiber Bristle Row: Heavy debris. C. Walk-Behind Tape Dispenser: Tapemate. 1. Material: Enameled steel. 2. Front Wheel: Applies tape to cover as you walk it along. 3. Handle: Adjusts to operator s height. 4. Tape Support: Drop-in place. 5. Tape Size: Accommodates 3-inch wide tape. D. Seaming Tape: Covertape. 1. Temporarily covers overlap seams. 2. Transparent. 3. Easy to remove. 4. Leaves no messy glue residue behind. 5. Width: 3 inches. 6. Length per Roll: 36 yards. E. Protective Gymnasium Floor Cover Cleaner: Cleanmate. 1. Concentrated, anti-static cleaning solution. 2. Cleans and conditions protective gymnasium floor covers. F. Storage Cover: Covermate Storage Cover. 1. Covers and protects protective gymnasium floor covers stored on cover handling system. PART 3 EXECUTION 3.1 ASSEMBLY A. Cover Handling System: Protective Gymnasium Floor Covers ( ) - 8
9 1. Field assemble cover handling system in accordance with manufacturer s instructions. Specifier Notes: Include the following sentence when a manufacturer-approved assembly service will field assemble the cover handling system. 2. Field assemble cover handling system by manufacturer-approved assembly service. 3. Ensure casters and rollers operate smoothly without binding. B. Dual-Brush System: Mount dual-brush system on cover handling system in accordance with manufacturer s instructions. 3.2 PROTECTION A. Protect protective gymnasium floor covers and cover handling system from damage during construction. B. Do not use protective gymnasium floor covers or cover handling system to protect gymnasium floors during construction. END OF SECTION Protective Gymnasium Floor Covers ( ) - 9
Product Guide Specification
Reef Industries, Inc. 9209 Almeda Genoa Rd. Houston, Texas 77075 Toll Free (800) 231-6074 Phone (713) 507-4251 Fax (713) 507-4295 Web Site www.reefindustries.com E-Mail [email protected] Product Guide
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF)
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) PART 1-GENERAL 1.01 RELATED WORK SPECIFIED IN OTHER SECTIONS A. Electrical connections see electrical specifications. 1.02 SUBMITTALS A.
A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.
13310 FABRIC SHADE STRUCTURES FOR PLAYGROUND AREAS ************************************************************************************************************************ SPECIFIER: CSI Master Format
POP-UP TENTS 5 X 5 (STEEL ONLY) 8 X 8 (STEEL ONLY) EPS-DOUBLET.COM [email protected] 800 227 0337 1
POP-UP TENTS Pop-up tents by EPS-Doublet are fast up, fast down and otherwise hassle free, making them ideally suited for multiple venue set ups, trade show booths and traveling product demos and sampling.
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
Product Guide Specification
Stabilit America, Inc., dba Glasteel June 2005 285 Industrial Drive Moscow, Tennessee 38057 Toll Free (800) 238-5546 Phone (901) 877-3010 Fax (901) 877-1388 Web Site www.glasteel.com Product Guide Specification
SECTION 32 1816 PLAYGROUND SURFACING TILES
SECTION 32 1816 PLAYGROUND SURFACING TILES PART 1 GENERAL 1.01 SECTION INCLUDES A. Resilient playground safety surfacing tiles. B. Coordinate with work shown in other sections so the work is installed
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
MODEL HSR-007 Direct Drive Rolling Steel
MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: [email protected] Model HSR-007
ENTRANCE MATS & GRIDS
152 Rollins Avenue #102 Rockville, MD 20852 800-762-9010 240-780-3309 (f) http://www.americanfloormats.com ENTRANCE MATS & GRIDS PART I - GENERAL 1.01 Summary A. This section includes the following types
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1
FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1 Issue Date: 3/3/2009 Each furniture item scheduled in this specification manual is assigned a "key" code; each key code is crossreferenced
Here are trade show displays I'm sure will meet your goals. I can also find items priced within your expected budget.
Here are trade show displays I'm sure will meet your goals. I can also find items priced within your expected budget. Please review the items and let me know which ones you are interested in. You can also
1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.
CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Special Conditions and Division 1 Specifications
glass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB
SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB PRODUCT DESCRIPTION: BOON EDAM TOMSED MODEL TUT-65TMB STAINLESS STEEL BARCODE SCANNING ELECTRONIC REGISTERING TURNSTILE SCOPE OF OPERATION: A. The TUT-65TMB
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
SECTION 07 42 13 METAL WALL PANELS
Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: [email protected] www.alpolic-northamerica.com This MANU-SPEC utilizes
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.
CHANNEL LETTERING INDOOR & OUTDOOR TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS
CHANNEL LETTERING INDOOR & OUTDOOR SIGNAGE TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS [email protected] www.muizgraphics.com Tel: 905-362-0268
CUSTOMER FLOW MANAGEMENT
Reduce the length of queues and ensure fair service: With Turn-O-Matic customer flow management from METO your customers are served in turn. Studies show that customers who take a number from the system
SECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
Recommended Forklift Free System Features for Proper Safety and Ergonomic Operation
When re-designing material handling flow to address restricted use of forklifts (Forklift Free), equipment ergonomics and safety play a key role. Following is a list of equipment and corresponding features
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps
BAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 -
BAGGAGE HANDLING SYSTEMS Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 - TECHNICAL SPECIFICS INDEX Check-in with one conveyor 4 Scales 6 Belt Conveyors 8 Take away 9 Feeder and Belt
Fish Grader User Manual
Fish Grader User Manual 1400 Fish Grader Contents Basic Parts... 2 Set up... 3 Control board needs to be setup... 3 Adjustable legs... 3 Adjustable Inlet cute... 3 Motor... 3 Control-board... 4 Remote
Corrugated Plastic Signs
Thank You for your interest in Beiler Printing. This catalog contains sample pricing, please call or visit us for a firm quote on your next project. Corrugated Plastic Signs Corrugated plastic signs make
Preface nivtec.com 3
nivtec.com Preface nivtec.com 3 nivtec 4 nivtec.com Planning with an Eye for Details nivtec.com 5 prolight+sound 2012 6 nivtec.com Meeting Point Fair Booth nivtec.com 7 Our Preparations 8 nivtec.com Enable
FLOOR TREATMENT 09610
14805 E. Moncrieff Place Aurora, CO 80011 Phone: (800) 872-5515 Phone: (303) 371-1411 Fax: (303) 371-6958 E-mail: [email protected] www.bonakemi.com This MANU-SPEC utilizes the Construction Specifications
SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex
(Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying cold-formed metal deck framing products and execution. The specifier needs to edit the guide
Division 9. SignaFlor Pad and Pour Flooring System
Division 9 SignaFlor Pad and Pour Flooring System SPECIFICATIONS Page 1. General... 2 1.1 Description 2 1.2 Quality Assurance 2 1.3 Submittals 2 1.4 Delivery and Storage 3 1.5 Warranty 3 1.6 Working Conditions
DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION
SECTION 230713- ALUMAGUARD ENGINEER SPECIFICATION DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
Bafl-Sorb Sound Absorbing Ceiling Baffles
Bafl-Sorb Sound Absorbing Ceiling Baffles INC offers a complete line of Sound Absorbing Ceiling Baffles to compliment any environment. Our ceiling baffles are among the most cost-effective method of adding
Banner Stands & Displays
Banner Stands & Displays LEARN MORE ABOUT WHAT WE CAN DO! Looking for a trade show banner stand and display? Showcase your banner anywhere with these high-quality stands and pop-up display systems. If
Service Manual SSCI. The Care and Maintenance of Casters. Wheeling, IL (800) 323 7366. Form No. 702755 11/06
Service Manual The Care and Maintenance of Casters SSCI Wheeling, IL (800) 323 7366 Form No. 702755 11/06 Service Manual Table of Contents General Information... 3 Introduction... 3 About this Manual...
CLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
ACOUSTIC PRIVACY SCREENS
ACOUSTIC PRIVACY SCREENS INDEX ACOUSTIC PRIVACY SCREENS Afford-A-Wall Folding Mobile Room Divider (Fabric)... 1 Afford-A-Wall Folding Room Divider (P olycarbonate)... 5 Afford-A-Wall Sliding Mobile Room
Reflective Safety Products. Home Automotive Commercial
Reflective Safety Products Home Automotive Commercial Driveway Markers 2673 2689 2707 2706 2708 2661 2662 2690 12" Foot Spike 36" 46" 2673 12 Mini-Marker 6-Pack 2689, 2707 36 Driveway Marker 2706, 2708
Display & Exhibit Systems
Display & Exhibit Systems 2016 Catalog NEW - Ripple Expandable Banner Stand System - page 4 EXPO Ready Retractable Banner Stand Our flagship banner stand - quality construction, great features and a fantastic
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS
3M Dual Lock Reclosable Fastener
3 Dual Lock Reclosable Fasteners SJ3550CF (Type 250) SJ3551CF(Type 400) SJ3552CF(Type 170) Dual Lock Reclosable Fastener Black with a clear acrylic adhesive Product Information February, 2007 Product Description
Thomas and Betts Corporation Product Guide Specification
Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described
A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
STANDARD FOR NON-FIRE RATED ROLLING DOORS
ANSI/DASMA 203-2004 AMERICAN NATIONAL STANDARD STANDARD FOR NON-FIRE RATED ROLLING DOORS Door & Access Systems Manufacturers Association, International Sponsor: 1300 Sumner Ave Cleveland, Ohio 44115-2851
FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING 21 11 00
211100_flexheadin_01_MS_0409 5/22/09 PTC 56 Lowland Street Holliston, MA 01746 Phone: (800) 829-6975 Phone: (508) 893-9596 Fax: (508) 893-6020 E-mail: [email protected] www.flexhead.com This MANU-SPEC
Fabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1" 1.5" x 1.
Features: Will not rust. Corrosion resistant. Non-sparking. Fire retardant. Non-conductive. Maintenance free. Molded-in color. Light weight. Easy to install. Impact resistant. Quality appearance. Fabcograte
SECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
SECTION 08330. FireGard ROLLING FIRE DOORS / SMOKESHIELD FIRE DOORS
SECTION 08330 FireGard ROLLING FIRE DOS / SMOKESHIELD FIRE DOS GENERAL NOTES TO SPECIFIER: THIS SPECIFICATION SECTION HAS BEEN PREPARED TO ASSIST DESIGN PROFESSIONALS IN THE PREPARATION OF PROJECT OFFICE
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
Specifications, Product Testing and Terminology
Specifications, Product Testing and Terminology The following synopsis provides a review of various material and final product testing, which is performed on our products, as well as, many of our competitors.
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 (See Supplemental Instructions for trailers with heavy duty round footplates and/or Power Leveling Systems) PHONE SUPPORT
SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS
PART 1 GENERAL SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear dual reflective, neutral sputtered and aluminum metallized polyester film for solar control. 1.2 RELATED
Fire Barrier Duct Wrap 15A
3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies
ATI Evaluation Service A Division of Architectural Testing Certification Services
ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 09/01/2016 Issued: 09/04/2015 Visit www.ati-es.com for current status Page 1 of 17 UFP Ventures II,
Dock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR
COMMERCIAL ITEM DESCRIPTION CLOTH AND STRIP, LAMINATED OR COATED, VINYL NYLON OR POLYESTER, HIGH STRENGTH, FLEXIBLE
INCH-POUND A-A-55308 May 13, 1997 COMMERCIAL ITEM DESCRIPTION CLOTH AND STRIP, LAMINATED OR COATED, VINYL NYLON OR POLYESTER, HIGH STRENGTH, FLEXIBLE The General Services Administration has authorized
SECTION 33 12 19 FIRE HYDRANTS
SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.
Table of Contents PRODUCTS. DYE SUB POP UP CANOPIES P. 3-4 Dye Sublimated Canopy... Attract Customers, Increase Brand Awareness & Say it in Color!
PRODUCTCATALOG Table of Contents PRODUCTS DYE SUB POP UP CANOPIES P. 3-4 Dye Sublimated Canopy... Attract Customers, Increase Brand Awareness & Say it in Color! TEARDROP BANNERS P. 9-10 Ideal for both
FRICTION MATERIALS & BONDING SERVICES
FRICTION MATERIALS & BONDING SERVICES World Class Friction Materials & Bonding Services The Industry Leader Midwest Brake has been a leading supplier of non asbestos industrial friction material and bonding
- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
CLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
rousseau MODULAR DRAWER SYSTEMS
rousseau MODULAR DRAWER SYSTEMS The rousseau Modular Drawer With a new design and improved performance, the Rousseau Modular Drawer is the best in its category. It permits faster inventory and ensures
PaLLe t trucks Lifting carts t r g in t if L 2435 6815 6836 6856 6842
l i f t i n g c a r t s Lifting carts The prograe for lifting, transporting and storage From the classical forklift trolley to the machine lifter, from furniture dollies to a chassis with 24 tons load
ITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING
DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings
Introduction: Consumables - Part of the Identification System
Consumables - The Basics A presentation from: Introduction: Consumables - Part of the Identification System You have spent many hours researching, selecting, and getting approval for your new data collection
2016 DISPLAYS & GRAPHIC SUPPLIES 801.973.8929 STORE.VISIONDOESIT.COM LOOK GOOD. BE SEEN.
LOOK GOOD. BE SEEN. 2016 DISPLAYS & GRAPHIC SUPPLIES 801.973.8929 STORE.VISIONDOESIT.COM RETRACTABLE BANNERS FLAGS TENSION DISPLAYS TABLE THROWS A-FRAMES CONTENTS 2-9 SINGLE-SIDED RETRACTABLE BANNER STANDS
Linkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
SECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
multi-axis system ROBOTRAX cable 3D cable carrier system carrier
3D cable multi-ais 3D cable carrier system carrier system Key Features: Perfect for 3D multi-ais movement applications. Maintains a pre-determined minimum bend radius Open-style design allows for easy
BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.
BOQ SPECIFICATIONS VERTICAL BLINDS Vertical Blinds made of glass fibre fabrics in width 5 (or 4 ). Minimum overlapping of ¾ in fabric. Top aluminium anodized rail of 1.4 mm thickness. 2 inch wide channel
In-Track Repair of Concrete Ties. Deland Humpherys, Director Track Mtce
In-Track Repair of Concrete Ties Deland Humpherys, Director Track Mtce Concrete tie repairs: Shoulder repair process Normally the result of a derailment Lag removal and replacement process Broken lags
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
1000-LB. TRAILER JACK OWNER S MANUAL
1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
Operating Instructions
566DG Ortho-Biotic Clinical Care Drop Arm Recliner Operating Instructions 566DG-INS-LAB Graham-Field Health Products 2005 IMPORTANT: READ THIS MANUAL BEFORE OPERATING YOUR ORTHO-BIOTIC CLINICAL CARE DROP
1.02 SYSTEM DESCRIPTION
1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall
Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023
Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural
EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction
Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to
Choosing the Right Floor Protectors
Choosing the Right Floor Protectors You ve made the investment in new flooring for your home. So what can you do to help ensure your flooring stays looking like new? One of the biggest flooring maintenance
SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.
SECTION 08333 ADVANCED UPCOILING SECURITY GRILLE MODEL 600 ADV Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Advanced Upcoiling Security Grilles,
1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
Phoenix-3W Series One-Way Security Revolving Doors
Phoenix-3W Series One-Way Security Revolving Doors ONE-WAY SECURITY REVOLVING DOOR SPECIFICATIONS ARCHITECTURAL SPECIFICATIONS Phoenix-3W Series One-Way Security Revolving Door Division 8 Doors and Windows
TABLE OF CONTENTS INTERIOR BANNER DISPLAYS 2-4 LIGHT BOX DISPLAYS 5 EXTERIOR SIGN DISPLAYS 6 HARDWARE 7-9
DISPLAY CATALOG TABLE OF CONTENTS 2-4 LIGHT BOX DISPLAYS 5 EXTERIOR SIGN DISPLAYS 6 7-9 Whether you need a small yard sign or an oversized banner display, look to Signs and Graphics by FedEx Office to
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic
Operating Instructions
566G Clinical Care Recliner Operating Instructions 566G-INS-LAB Graham-Field Health Products 2005 IMPORTANT: READ THIS MANUAL BEFORE OPERATING YOUR CLINICAL CARE RECLINER WARNINGS Warning: Read entire
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
REQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $
REQUEST FOR QUOTE Specifications- Knightdale Station Park Naming Rights Exterior Signage General Conditions 1. Delivery of signs to be within 6 weeks of order confirmation. 2. Shop drawings are required
A. Shop Drawing submittals shall include, but not be limited to, the following:
SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical
127 PCS. Art. NO. 712701 Art. NO. 712702 Art. NO. 712703. www.sonic-equipment.com
7 PCS Art. NO. 770 Art. NO. 770 Art. NO. 770 8 drawers with ball bearing slides drawers completely filled with 7-pcs tools drawer blocking system, as protection against tipping over abs topblade can holder
AirBlock Data Center Doors
Data Center Doors AirBlock Data Center Doors What makes AirBlock the best? Works with your existing hot aisle/cold aisle isolation system. Doors accommodate different racks within the same data center;
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H Soil Drainage Mat with Built-In Protection Layer POLYGUARD DRAINAGE MATS are three-part prefabricated geocomposite drain consisting of a
