1 ADVANCED BOILER DESIGN Flemming Skovgaard Nielsen Carsten Søgaard October 2014

2 TABLE OF CONTENTS 1 Abstract Introduction Tower Type or Two Pass Type Advantages & Disadvantages Ultra Super Critical Pressure Part Material Selection Feed Water System Return of investment Double Reheat Once Trough Design Benson Minimum Minimum Boiler Load Load Jump & Load Change Rate Advanced Combustion System Air Staging NO x Performance CO Corrosion Protection Tangential Firing or Opposed Firing Fuel Flexibility Co-combustion Multi Fuel Concept Case: Avedøre Unit 2 (Denmark) Case: Hazira Unit 1 & 2 (India) Single Train or Double Train Advantages & Disadvantages Availability Single Train Design Selective Catalytic Reduction Split Economizer... 22

3 12 Controlled Safety Pressure Relief Systems (CSPRS) CSPRS or Traditional Safety Valve Operational Modes Pipe Layout APH Sealing System Sealing Systems Future Advanced Boiler Design Conclusion (BAT)... 27

4 1 ABSTRACT Introducing advanced boiler concepts in the design of thermal power stations is nowadays becoming mandatory. Not only from an economic point of view, but also as a proactive step towards reduction of emissions, the enhancement of efficiency becomes inevitable. The increase in the cycle efficiency in modern power stations is mainly achieved by increasing the steam parameters. The technological steps in advanced boiler design therefore imply shifting steam parameters from sub critical to super critical to ultra super critical. In addition to elevated steam parameters other measures like double reheat and increased boiler efficiency are key players in achieving the desired maximization. Such performance achievements comes only through a 360 approach involving design features like: Fuel Flexibility Tangential Firing System Full Air Fuel Ratio Control (Individual Burner Control) Reduced Air Excess Safe Evaporator Design Easy SCR Implementation Effective Air PreHeater Design Single Flue Gas Train Compact Design (Short Routing) Danish power plants are in this sense design and performance wise understood to define the elite. These plants are designed and supplied by Burmeister & Wain Energy (BWE) which over decades has build knowledge and experience to design boilers with unmatched efficiency and reliability. This paper outlines the expertise in achieving the goal of high boiler and cyclic efficiencies. Benefits of the Tower Type Boiler design in comparison with Two Pass Type Boiler design are analyzed and described. Operational flexibility of modern power stations is achieved by the Benson technology in combination with sliding pressure, a well proven, reliable and effective operational mode. The material selection in a modern boiler, as the key player of supercritical and ultra supercritical design, is described and showing good results on long term basis. The controlled safety valve concept is analyzed in comparison with the spring load type. Finally knowledge and experience within multi fuel concepts as well as co-combustion of biomass in ultra supercritical boiler are summarized. BWE has been a member of the European COMTES700 initiative on advanced USC technology. The highlights are touched in view to see synergistic possibilities with the similar Indian program.

5 2 INTRODUCTION The objective of this paper is to describe the main features of advanced utility boilers reflecting the state of the art clean coal technology adopted and developed. It is an update of a paper issued in January It has been updated with information about latest development and experience from design and operation of commissioned boilers, and highlights the advantages and limitations of once through tower type boiler with advanced steam parameters and the more well known two pass drum boilers with moderate steam parameters. 3 TOWER TYPE OR TWO PASS TYPE Since the mid 19 th century two pass boilers have been the preferred boiler design in Europe. During this period mainly two pass boilers has been supplied to the Danish utilities in the range from 80 MWe to 640 MWe. Since the oil crisis in the 1970 s, utility boilers have all been pulverized fuel (PF) fired based on imported coal, typically bituminous coals, from Poland. In the 1980 s the market required more flexible and effective boilers with high focus on boiler efficiency, load change rate and fuel flexibility. It was decided to introduce the tower type design for utility boilers. In 1984 a 150 MWe front fired tower type boiler for Volkswagen in Germany and following this in 1988 a 400 Figure 1: Fyn Unit 7, 400 MWe, Denmark. Two Pass Boiler. MWe tangential fired tower type boiler for Walsum as Unit 9 in Germany were supplied. Since then the main part of the 400 MWe class boilers in Denmark have been of the tower type design and supplied.

6 3.1 ADVANTAGES & DISADVANTAGES Advanced Boiler Design 2014 The tower type design has in comparison with the two pass design a number of advantages such as the reduced foot print, reduced weight of boiler pressure part, easy installation of selective catalyst reactor (SCR), fully drainable pressure part, no intermediate extraction of fly ash and uniform flue gas temperature profile over furnace cross section FOOT PRINT The foot print of the tower type boiler will be smaller than the one of the two pass boiler. The tower type design also enables a very compact design of the boiler, SCR and APH (air pre heater). The reduced foot print subsequently leads to a reduced boiler steel structure even though the total height is increased HEATERS Since the heating surfaces of a tower type boiler are affected by a flue gas flow perpendicular to the banks, the heating surface will be fully effective in contrast to the hanging super heaters of the two pass boiler where the heat absorption are less defined and the efficiency reduced. Subsequently the weight of the pressure part of a tower type boiler will be reduced compared to a two pass boiler. All heating surfaces are arranged horizontally resulting in a fully drainable pressure part. Especially during start up condensate can leave the system, pipes heated up and steam temperature increased faster. For short overhauls dry preservation can easily be used. Figure 2: Nordjylland Unit 3 (NJV3) 415 MWe, Denmark. USC Tower Type Boiler Steam side oxidation and increased formation of magnetite (Fe 3 O 4 ) layers inside super heater tubes is critical in USC boilers. The risk of blocking the super heaters by exfoliated magnetite is considerably reduced in tower type boilers with horizontally arranged super heaters.

7 3.1.3 FLUE GAS PATH The arrangement of boiler and APH makes it intuitive and easy to install SCR. Ammonia injection will be installed after the boiler outlet, followed by a static mixer ensuring a uniform flue gas distribution at the SCR reactor inlet. With a flue gas path arrangement from the boiler top and down through the SCR and APH no additional or intermediate fly ash extraction is needed. This would be the case for a two pass boiler design as the flue gas flow changes from downward to upward below the ECO. When leaving the APH, the flue gas proceeds horizontally, allowing the hoppers below the APH to be designed only for APH washing water collection and not for fly ash extraction. All the fly ash will end up in the filter. The tower type design in combination with tangential firing results in a very uniform flue gas temperature profile entering the first super heater. Temperature peaks in the flue gas profile are thus avoided resulting in less temperature imbalances in the super heaters. This is highly important for materials operating at their limit within the creep range ERECTION The dominating advantage of the two pass boiler is it s lower height and easier erection of the boiler top including headers, heating surfaces and boiler ceiling. However the design of the boiler top of a two pass boiler is often quite complicated. The boiler ceiling of the tower type on the other hand is uncooled and the boiler suspension is simple and does not require penthouse. In light of a better performance over a life time of more than 35 years a few extra months for construction of the tower type boiler should easily be accepted DESIGN FEATURES The two pass boiler has a number of design limitations which are difficult to avoid. Temperature difference between first pass and vestibule / second pass membrane wall will often lead to cracks after some years of operation. The tower type boiler has a very simple design of membrane walls and a smooth increase in temperature. When the flue gas leaves the first pass and enters into the second pass another problem arises. Particles within the flue gas concentrates in proximity of the rear wall of the second pass and evoke erosion of the super heater banks. For high ash coal this is a challenge that normally calls for erosion shields. The two pass boiler has some geometrical limitations which makes it difficult to optimize the boiler pressure part design. The pitch of the first hanging super heater bank SH-1 requires a mutual distance ( mm) to avoid blocking of slag. In the tower type boiler the first super heater bank SH-1, which is typically arranged just above the final reheater, can be designed with

8 smaller pitch ( mm). The number of parallel tubes can thus be higher and subsequently the pressure loss will be smaller. Boiler Type Comparison Tower Type Uniform flue gas profile. Reduced temperature peak in pressure part Excellent RH temperature characteristic Effective heating surfaces. No ineffective (dead) zones. Reduced footprint & Increased height. Low pressure loss due to high number of parallel tubes in super heater banks Easy SCR installation Smooth membrane wall temperature increase No extraction of fly ash Fully drainable super heaters. Fast start up. Simple boiler suspension. Penthouse not required Figure 3 Comparison of Tower Type and Two Pass boiler design. Two Pass Type Uneven flue gas flow profile. High ash concentration on 2. pass rear wall Cold built in conditions for final RH Partly ineffective heating surfaces Enlarged footprint & Reduced height. Higher pressure loss due to limitation in heating surface design Complicated installation of SCR and increased duct work Thermo stress and cracks in membrane wall between first pass and vestibule - second pass Extraction of fly ash below ECO Risk of blocking the hanging super heaters by exfoliated magnetite. Complicated boiler suspension. 4 ULTRA SUPER CRITICAL The USC boiler operates at high efficiency resulting in lower fuel consumption for electricity generation. The combustion in the USC boilers will therefore lead to a reduced CO2 emission compared with other type of boilers. Plant Reference Table Plant Year Size Type Country ReHeat FW Temp HP Pres HP/RH temp. Efficiency [-] [-] [MWe] [-] [-] [-] [ C] [bar] [ C] [%] Asnæs Unit Two Pass Denmark Single / Walsum Unit Tower Germany Single / Fyn Unit Two Pass Denmark Single / Staudinger² Tower Germany Single / Skærbæk Unit Tower Denmark Double /580/580 49¹ Nordjylland Unit Tower Denmark Double /580/ Avedøre Unit Tower Denmark Single /600 49¹ Porto Tolle Unit 2, 3 & 4 Design 3x660 Tower Italy Single / ¹ Avedøreværket Unit 2 & Skærbækværket Unit 3 are designed for coal, but are operating on BIO & NG. Calculated plant efficiency for Avedøreværket on coal is >48 %. ² Scope partly by BWE and partly by Deutche Babcock Figure 4 Plant Reference Table of SUBC, SC and USC. BWE has designed a number of 400 MW USC boilers which have been in operation since The data from actual operation shows a very high plant efficiency and high availability, please refer to Figure 16. The boilers are operated with steam parameters of bar and

9 Stress [N/mm²] x 10E0 Advanced Boiler Design 2014 C. New USC boilers like Porto Tolle 3x660 MWe have been designed using steam temperatures of C. 4.1 PRESSURE PART MATERIAL SELECTION SUPER & REHEATERS The elevated steam parameters require higher grade pressure part materials. Final HP superheater banks and final RH banks are made in austenitic steel. In order to reduce steam side oxidation, fine grain austenitic materials are selected. Relevant materials are TP347HFG (ASME Code case 2159) and TP304CuCbN (ASME code case 2328) 310N/HR3C and Sanicro25. The two latter with 25% Cr and subsequently high raw material cost. TP304-CuCbN calls for inner shot peening in order to obtain sufficient fine grain structure. An enhanced version of TP304 is the Super304H material Allowable Stress Nation: Denmark, Material Code: EN12592 & ASME Dimensions: Ø33.7x4.5 X10CrMoVNb9-1 (P91) X10CrWMoVNb9-2 (P92) Super304H TP347HFG Temperature [ C] For main steam and hot reheat steam lines at C the traditional material P91 is no longer sufficient. On the 400 MW USC Figure 5 Allowable Stress Chart: T91, T92, TP347HFG & Super304H. boiler at Avedøre Unit 2 (AVV2) the outlet headers and the steam lines are made fully in P92. P92 is a 9% Cr martensitic steel like P91 however with improved creep range data due to W alloy MEMBRANE WALL When ultra super critical boilers operate the materials after the evaporator are mostly in the creep range. Due to the elevated steam temperature, the materials operate in the creep range on the edge of what is possible. A small increase in temperature will result in a tremendous reduction of allowable stress. It is therefore essential to reduce the temperature imbalances in the boiler by correct boiler design. This is possible by a number of well proven measures as uniform flue gas profile as result of Tangential Firing, intermediate outlet headers, crossover of steam from left to right boiler side and extraction of main steam via four outlet headers instead of only two. I has to some extent become the perception that T22 (2,25Cr-1Mo) and T12 (13CrMo4-5) do not have sufficient creep strength to be used in membrane water walls of ultra super critical boilers. Contrary to this perception BWE design has proven that T12 material for up to 300 bar is highly reliable. Also the upper pass with vertical membrane wall is often made in T12 material with

10 Stress [N/mm²] x 10E0 Advanced Boiler Design 2014 design temperatures up to 500 C. Today 15 years of successful experience with several USC boilers operating with membrane walls made in T12 are obtained. A membrane wall design using T12 is however only possible through a detailed and careful design with focus on reduction of temperature imbalances and stress concentrations. This requires and integral investigation of every individual tube performance in the membrane wall and subsequent design corrections. Actual operation has shown that chemical cleaning of the evaporator after hours is needed. Figure 6 Heat flux distribution resulting from Tangential Firing. An important precondition for a proper evaporator design is a combustion system resulting in well distributed heat absorption. On the tangential fired boilers the spiral helical rotation is opposite to the combustion vortex resulting in minimum temperature imbalances at spiral transition outlet. Figure 6 shows a membrane wall study with a even heat flux distribution as a result of a proper designed evaporator and combustion system EXTENDED MATERIAL SELECTION It is possible to increase the steam parameters even further by using T23 material (ASME Code case 2199). The T23 material has good creep resistance up to 550 C and was developed in order to avoid PWHT. T23 is an extension of T22 modified by adding mainly W and reducing Mo and C content Allowable Stress Nation: Denmark, Material Code: EN12592 & ASME Dimensions: Ø33.7x4.5 Severe problems with cracks in Membrane Wall weldings of T24 have been observed on German boilers. However T23 is very sensitive to deviation in welding parameters. Also some investigations concerning secondary hardening of steels containing vanadium show, that non-tempered welded joints undergo a significant increase in hardness during exposure at operating temperature CrMoVTiB10-10 (T24) 7CrWVMoNb9-6 (T23) 10CrMo9-10 (T22) 13CrMo4-5 (T12) Temperature [ C] Figure 7 Allowable Stress Chart: T12, T22, T23 & T23.

11 Stress [N/mm²] x 10E0 Advanced Boiler Design 2014 PWHT is therefore unavoidable for larger dimensions but might still be avoided for smaller dimensions. In 2009 a small Benson boiler of 350 MWt heat input using T23 as membrane wall material was successfully commissioned. In order to avoid PWHT concern has been directed to the design of T24 (7CrMoVTiB7-7). T24 is a further development of T23 and modified by adding Ti, increasing Mo and removing W. T24 however has not fulfilled the design intention and does as T23 require PWHT. Cracks in T24 membrane wall welds without PWHT have been reported in some European power plants. In some cases severe to an extent requiring replacement of the entire membrane wall. 4.2 FEED WATER SYSTEM Studies of the cycle calculations including a number of preheaters have indicated that there is an optimum plant efficiency using FW temperatures at approximately 320 C. Using the traditional material SA-106 C for the FW system and inter connecting piping down to the evaporator inlet results in high wall thicknesses. When introducing USC technology with design pressure above 250 bar, it should be considered to use alternative materials Allowable Stress Nation: Denmark, Material Code: EN12592 & ASME Dimensions: Ø33.7x4.5 15NiCuMoNb5-6-4 (Wb36) SA-106 C In Europe it has been a common practice for more than 20 years to use the material 15NiCuMoNb5-6-4 also known under the trade name Wb36 (ASME Code Case 2353). Wb36 is a weldable high temperature copper-nickel-molybdenum steel alloyed used up to 371 C (450 C acc. EN Code). Using Wb36 the wall thickness can be reduced by 25 % resulting in cost savings on material, welding, induction bending, hangers, support structures and resulting in a more flexible pipe system. Valve manufacturers have today included the material in their standard program. 4.3 RETURN OF INVESTMENT Temperature [ C] Figure 8 Allowable Stress for SA-106 Gr.C & Wb36 (ASME Code Case 2353). When the total amount of materials for the boiler pressure part is evaluated, it is clear that the extra cost of applying USC steam parameters is very limited compared to the total amount of materials for boiler pressure parts (additional cost 6-8%). When the remaining part of the boiler or the plant is taken into consideration the extra cost for an USC boiler is negligible.

12 Advanced USC boilers will have a plant efficiency above 45 %. It now becomes obvious that the investment will be returned in relatively short time. The coal fired 400 MW USC boiler Nordjylland in Denmark designed with double reheat cycle was supplied and has been in operation since 1998 with a proven plant efficiency of 47 %. 5 DOUBLE REHEAT One of the obvious initiatives to increase cyclic efficiency is to introduce the double reheat cycle. This will increase the plant efficiency by approximately 1 %. Two of the 400 MW USC boilers supplied are designed with double reheat cycle. When boilers are designed with double reheat it is important to make accurate boiler calculations and to balance the heat absorption between the two RH parts. Even with increased cost for the turbine, for additional pipe work and for valve arrangement it is commercially attractive to design with double reheat cycle in countries with high electricity costs and emission taxation. Double reheat is a natural and well proven technology to be used in the effort towards the 50 % efficiency (LHV). 6 ONCE TROUGH DESIGN Since 1852 steam generating plants for industry and power stations has been supplied. It is thus one of the oldest still existing manufacturers of steam boilers in the world. In 1955 BWE acquired a license for the Benson once-through boiler design and has since then been one of the leading companies for advanced boiler designs. The tendency in Europe is that all new boilers from 300 MWe and upwards are of the once through design. However drum type boilers are still in the portfolio, since small scale boilers and specially grate fired biomass boilers with heat input MW are still of the drum type design. The advantages of a once through boiler design is described below in detail. First of all once through boilers are not limited in pressure as the drum boilers where circulation is linked to the difference in water and steam density. Thus the plant cycle can be increased by increase of steam parameters above the critical point. The limitation on once through boilers is mainly linked to the selected materials for pressure part and turbine design. Furthermore when a drum boiler is designed to operate close to the critical pressure, the split between the evaporator and the super heater becomes a challenge. If no special designs are introduced, the evaporator part of the boiler often becomes too large since the membrane walls of the first pass all are designed as evaporator.

13 When the boiler has to be designed for a variation of coal types available on the market and is to operate according, the sizing of the evaporator becomes critical. The different coals result in different heat absorptions and for drum boilers the evaporator is fixed. Once through boilers are more flexible with respect to heat absorption since the evaporation fully takes place in the furnace and superheating starts already in the membrane wall. 6.1 BENSON MINIMUM Below a certain load called the Benson minimum load it is necessary to maintain sufficient flow through the evaporator by forced circulation. The forced circulation is established by a circulation system working either via dedicated boiler circulation pump (BCP) or via circulation through Feedwater Tank, Deaerator and FW Pump. The Benson Minimum load is normally at 35 % boiler load depending on the design of furnace membrane wall. A proper boiler design includes correct decision on number of parallel tubes, pitch and inner diameter of membrane wall tubes. In circulation mode (< 35 %) the water and steam leaving the evaporator is separated in the cyclone separators and the water is lead to the level vessel. From the level vessel the water goes to the circulation system. 6.2 MINIMUM BOILER LOAD Recently utilities have required boilers capable of operating at low load condition and ready to follow the electricity demand quickly. Subsequently it has therefore become essential to keep the boiler in operation during night and weekends at low load condition. Minimum Boiler Load on coal without support firing is typically possible down to 25% boiler load depending on coal composition and mill design. 6.3 LOAD JUMP & LOAD CHANGE RATE The drum type boiler has a certain amount of energy accumulated in the large portion of water in the evaporator and drum. Load jumps can therefore be performed by reducing pressure and release more steam to the turbine. The amount of water in the once through boiler is very limited however load jumps can easily be made by known and proven methods. Load jumps can e.g. be executed via bypass of HP preheaters, LP preheaters or condensate stop depending on the cycle arrangement. Planned load jumps can also be executed via prethrottling of either HP or IP turbine valves by operating the boiler in modified sliding pressure mode as described below.

14 The once through boiler with a BWE designed combustion system can firmly follow a load change rate of 5 %/min in the range from % boiler load. 7 ADVANCED COMBUSTION SYSTEM The combustion system consists of Low NOx Burners, Over Burner Air (OBA) and Over Fire Air (OFA). The combination is well proven and since 1990 more than 500 of burners handling a variety of fuels have been commissioned worldwide. In addition a tangential firing technique has been developed using circular burners with air staging. By inclusion of OFA this system supports in-furnace air staging resulting in further reduced NO x formation. The complete combustion system is used in the most recent USC boilers in Denmark and with a fuel range including Coal, HFO, NG and Wood Dust. For Fuel Flexibility please refer to Section AIR STAGING Air Staging is a key feature in Low NOx burner design. It builds upon a principle of sequential combustion which basically means applying enough air in each stratum to make the combustion stable, but not enough to allow nitrogen to be oxidized to NO or NO2. The main parameters governing NOx formation is local gas temperature and composition which are kept under control through Air Staging. In Low NOx burner designs the combustion air is controlled to form a stratified mixing of fuel and air. The result is stretched flames and combustion zones where simultaneous high temperature and high Air Fuel Ratio (AFR) are avoided. Figure 9 BWE Combustion System with Low NO x Burners, OBA & OFA. OFA affects an increase in excess air to λ = 1,15 1,17 at ECO outlet. Low NOx Burners with air staging involves individual control of the SA and TA air for NG Combustion and in addition to that a certain control of the PA air for Coal Combustion. The split between SA and TA air is also controlled. For optimal operation SA and TA can be added swirl using the SA & TA turbulators which can either be positioned manually or electrical actuated. The required air staging and swirl depends on a number of factors such as load, fuel composition and burner level. Figure 10 Two 69 MWt BWE Low NO x Burners with OBA in a Tangential fired boiler.

15 The purpose of the swirl is to control and ensure a homogeneous and optimal air-fuel mixture in the stratum. It also serves to control the penetration of the flame into the furnace. A high swirl leads to a short flame and an internal recirculation zone. This implies a flue gas recirculation at each combustion zone which together with the air split control supports Low NOx formation. It is important to stress that Low NOx Burners in Wind Box applications requires special techniques at commissioning for determination of various burner settings. BWE uses an in-house developed algorithm during commissioning to obtain optimized Low NOx operation. 7.2 NO X PERFORMANCE The combustion systems five air flows can be summarized as below, and of which the first three are located concentrically within the burner. 1. Primary Air (PA) 2. Secondary Air (SA) 3. Tertiary Air (TA) 4. Over Burner Air (OBA, Above each burner) 5. Over Fire Air (OFA, Air nozzles above the burner zone) By implementing Low NO x Burners the NO x level can as a single entry be reduced by % compared to traditional coal burners. With air staging the overall Air Fuel Ratio in the burner zone is reduced to just above stoichiometry ( 1.05) which results in an enhanced NO x performance. By extending the air staging to the furnace by use of OBA and OFA the NO x level is reduced by % compared to a high NO x combustion installation. 7.3 CO CORROSION PROTECTION In contrast to traditional jet burners in similar tangentially fired systems, the circular burner provides an annular airside protection against CO corrosion of the furnace membrane wall. This protection is enhanced by the use of the OBA which maintain a boundary layer at the membrane wall with higher stoichiometry. Figure 11 BWE Low NO x corner burner with central gas lance, oil lance and three concentrically air flows: Primary (PA), Secondary (SA) & Tertiary (TA). Burner design suitable for Multi Fuel Combustion.

16 8 TANGENTIAL FIRING OR OPPOSED FIRING Advanced Boiler Design 2014 When the Tangential Fired furnace is considered in a cross section, it is clear that there are no dead corners. It is also clear that front and opposed fired boilers will have dead corners near the burners close to the side walls. On this basis it is possible to operate a T-fired boiler with lower air excess without the risk of CO corrosion at the membrane walls than a front or opposed fired boiler. T-firing system for coal combustion with air excess down to 1,15 at ECO outlet are desigen. The combustion system for T-firing will have over burner air (OBA) injected just above each burner. The OBA is part of the air staging and contributes to a reduction of NOx formation. Furthermore the OBA ensures sufficient oxygen content Figure 12 CFD calculation of a 660 MWe tangentially fired USC boiler. along the membrane wall and in this way protecting the membrane walls against CO corrosion. No CO related corrosion is reported on T-fired boilers with such combustion system installed. The T-firing concept results in a very uniform flue gas temperature profile at the outlet of the furnace. The temperature imbalance in the first heating surfaces caused by the flue gas profile is therefore reduced significantly. In USC boiler design this is essential since the materials operates in the creep range where the allowable stress is dropping fast when the temperature is increased. Front, opposed or even worst box type boilers will have high temperature peaks in the flue gas temperature profile at the furnace outlet resulting in temperature peaks in the superheater banks. By T-firing it is possible to operate with longer flames and without swirl in tertiary air sectors of the burner. Front and especially opposed fired boilers are very sensitive to variation in the coal composition and the related shape of the flame. Often it is required with heavy swirl in order to reduce the flame length. In opposed fired boilers the flames will meet at the middle of the furnace and generate NOx.

17 9 FUEL FLEXIBILITY 9.1 CO-COMBUSTION Co-combustion of biomass and coal in utility boilers is today a proven technology. A heat input of % on biomass and possibly more is possible while maintaining the possibility of using the fly ash for cement production. The biomass can be straw, wood chips or wood pellets. Co-combustion of biomass can be conveyed through the PF coal piping or dedicated wood dust piping by installing a centre lance in the burner injecting pulverized biomass to the furnace. As for biomass, RDF (Refused Derived Fuel) can be injected into the furnace via an inner tube in the centre of the PF burner. 9.2 MULTI FUEL CONCEPT The combustion system and burners are designed for a multi fuel concept. The standard PF burner as presented in the Section 0 can be designed with an inner gas lance simultaneously with an inner HFO/LFO lance. The combustion system can be designed for 100 % coal, 100 % wood, 100 % gas and 100 % oil firing. In this way the fuels can be changed quickly and it is also possible to operate with different fuels on different burner levels. 9.3 CASE: AVEDØRE UNIT 2 (DENMARK) The 400 MWe multi fuel USC boiler Avedøre Unit 2 has 4 burner levels of each 4 burners each originally designed for coal, oil and gas. Shortly after commissioning the unit was converted to operate on 80 % wood dust and 20 % Natural Gas. In this case the coal pulverizes were rebuild for biomass grinding and conveyed via the existing PF piping to the burner. The retrofitted pulverizers work well but do not reduce the wood pellets particulate composition or particle size distribution significantly beyond its base. Operating with relatively coarse base composition in such design does however not pose a threat to combustion quality, when implemented on a tangentially fired boiler. As the particle trajectory is controlled by the furnace swirl and the travel thus much longer compared to opposed or front fired arrangements. The increased particle velocity and interaction facilitates particle burn out. The fuel concept on AVV2 up till today is a heat input of approximately 640 MWt of wood dust corresponding to 130 ton/h with an addition of 160 MWt of Natural Gas. Just recently AVV2 has been converted to 100 % wood dust firing.

18 9.4 CASE: HAZIRA UNIT 1 & 2 (INDIA) The 2x150 MWe multi fuel SUBC drum boilers Hazira Unit 1 & 2 has opposed burner arrangement in 3 levels with a total of 20 burners each. The multi fuel concept is composed to handle various waste fuels from a steel plant in Hazira. Burners and fuel systems are adequately designed to handle Coal, Corex Gas, HFO, LDO & Coal Dust that is emitted from the steel production. The Multi Fuel concept is a major advantage of the steel manufacturer as it uses the waste streams from the steel production as fuel. This is one of the strongest pay back cases. As the fuel primarily is waste from steel production, its cost is already incorporated in the steel unit price. Industries like the steel industry is demanding new boilers designed with a multi fuel firing Advanced Boiler Design 2014 Figure 13 Hazira 2x150 MWe Multi Fuel (Coal, Corex Gas, HFO, LFO) fired drum boilers for a steel plant in India. concept capable of utilizing the waste fuels from the steel production in order to improve the plant profitability and to avoid loss of energy. 10 SINGLE TRAIN OR DOUBLE TRAIN Single or Double Train Systems are often chosen by clients based on a matter of preference and tradition. The choice is to some extent value based, but there are a number of perspectives that can be applied to assess which might in fact be the more advantageous, economic and reliable. In Germany and Denmark there is a strong tendency to design new utility boilers with single train flue gas path and mono components and for several years boilers have been designed with only one Air PreHeater. Based on operational experience the availability of these plants is very high. All critical components like bearings can be designed for a high life time e.g. APH bearing typically for h.

19 9.5 ADVANTAGES & DISADVANTAGES For the Double Train solution the duct system and related equipment and are arranged as two parallels. This design therefore demands two ID Fans, FD Fans, PA Fans, APHs, SCRs etc. and in addition to that as large number of dampers. The components are normally arranged in ways that allows to run the boiler at 60 % load with one FD Fan out of operation. Advanced Boiler Design 2014 Train Design Comparison Single Train Double Train FD Fan 1 2 PA Fan 1 2 ID Fan 1¹ 2 APH 1² 2 Dampers 0 16³ Duct Work Reduced Extended Pressure Loss Low High SCR 1 x 100 % 2 x 60 % NH3 Injection 1 2 ¹ To avoid high starting current, two fans can be installed in a Single Train Design. ² With two drives for redundancy. ³ Including sealing air. Figure 14 Single & Double Train Comparison For the Single Train solution the duct system and related equipment are arranged as a single and simplified path. This design therefore demands one ID Fan, FD Fan, PA Fan, APH, SCR etc. and with no dampers exposed to the flue gas. This Train Design Comparison is consolidated in Figure 14. Looking at the APH and analyzing the effect of single and double train it becomes clear that performance is vastly improved by single train while the total weight is slightly reduced. APH Design Comparison Single Train Double Train Quantity [-] 1 2 Type [-] Quad Sector Tri Sector Rotor Diameter [m] 23,44 16,11 Total Air Leakage [kg/s] 29,2 38,7 Total Weight [ton] Figure 15 APH Design for Single respectively Double Train on a 660 MWe boiler. APH is equipped with two 100 % drives. The two drives can be in operation simultaneously. In case one drive fails, the other will take over. From the comparison tables the main advantages of the single train design can be extracted: Lower Cost & Complexity (reduced number of components) Lower APH Leakage Rate (reduced from 8 % to 6 %)

20 Less Power Consumption SCR Design 100 % (not 2 x 60%) No Temperature Imbalances No Flow Imbalances No Dampers The disadvantages are not quite as obvious, however the following becomes true: Higher Load on Single Steel Columns (APH & SCR) Higher Starting Current (FD & PA Fan) The Single Train & Mono Component concept is referenced on plants up to 800 MWe and is strongly recommended for advanced boiler design. 9.6 AVAILABILITY The single train and mono component concept has been used for a number of boilers for more than 20 Years. The 400 MWe USC boiler at Nordjylland (NJV) Denmark has been in operation since 1998 with a very high availability, see Figure 16. When calculating the availability factor of Availability Overview Year Availability Cause ,7% Sootblowing Damage ,7% Thermo Well Failure ,0% Turbine Failure ,5% Membrane Wall Tube Leaking ,6% Turbine Failure % ,2% Membrane Wall Tube Leaking % % ,9% Welding Failure Figure 16 Availability of Nordjylland 415 MW USC. The availability is calculated exclusive of planned maintenance. single train mono component configuration, it can be proven that the total availability plant is higher than for double train and redundant systems, since the risk of failure is reduced significantly. For the Double Train configuration the quantity of components that actually can experience failure and affecting the load is simply superseding the quantity in the single train system. From a pure statistically point of view it is therefore more likely that a double train system will suffer failure that causes load reduction or trip.

21 9.7 SINGLE TRAIN DESIGN Beside being simpler the single train and mono component layout is also more compact. The SCR and APH are layout wise arranged in a tower like design. The single APH is typically arranged at elevation A single centre column is positioned at the boiler centre line supporting the APH main rotor bearing. Due to the large diameter (Ø23,5 m) of the APH rotor, the APH casing is supported by beams exceeding the footprint of the boiler itself. When mono component design is applied care must be taken to the electrical system in order to meet the required electrical loads. For a 660 MWe plant the typical electrical installation for FD and PA would be: Figure 17 Plant layout of Porto Tolle MWe USC Single Train. FD Fan Motor: RPM PA Fan Motor: RPM 10 SELECTIVE CATALYTIC REDUCTION The installation of an SCR has become mandatory in many countries. The operational requirements of the boiler influence the SCR design as it must be functional in the entire load range from 25 % to 103 % boiler load. The operational requirements for the SCR on the other hand also influence the boiler design. The acceptable flue gas temperature window for proper SCR operation is from 315 to 400 C. Short time operation of 2-3 hours below the 315 C is acceptable preconditioned that the temperature is increased above 350 C afterwards.

22 Previously boilers have been designed with SCR bypass used during start up. The Zero SCR Bypass concept is based on a full flow through the SCR during start up. All reference plants and recently built coal fired plants in Germany are designed without SCR bypass. 11 SPLIT ECONOMIZER The split of the economizer heating surface is necessary to ensure the best possible operating conditions for the SCR over the entire operating range of the boiler. The acceptable flue gas temperature window for proper SCR operation is from 315 to 400 C. The tower type design makes it easy to arrange a split economizer. The economizer is simply divided into two separate heating surfaces located before and after the SCR plant in the flue gas stream. The feed water is first lead to the economizer located after the SCR and from here it is led to the economizer at the boiler top. The total heating surface of the two economizers is sized to maintain the same heat absorption as for the basic design with a single economizer. The split ECO will lead to a reduction of the boiler steel structure and a reduction of the membrane wall height by about 1,5 m. Figure 18 Section view of Porto Tolle MWe arrangement of split ECO. 12 CONTROLLED SAFETY PRESSURE RELIEF SYSTEMS (CSPRS) 12.1 CSPRS OR TRADITIONAL SAFETY VALVE Preferably hydraulically operated safety valves are used in Advanced Boiler Design to protect the pressure part in power stations. In comparison to the use of spring loaded safety valves, the number of installed components can be reduced drastically by the use of combined bypass and safety Safety Valve Comparison Controlled Pressure Relief 100 % HP Combined Bypass Units with Safety Function Hydraulic Spring Loaded (two valves) 116 % RH Safety Valve Hydraulic Spring Loaded (two valves) Traditional Safety Valve 80 % HP Bypass Valves (two valves) 23 % HP Vent Valves (two valves) Shut Off Valves in Front of HP Bypass (two valves) 103 % HP Spring Loaded Safety Valves (two valves) 100 % RH Spring Loaded Safety Valves (two valves) 40 % RH Vent Valves (two valves) Figure 19 Comparison of CSPRS and Traditional Safety Valve System.

23 valves. Advanced boilers are typically equipped with following valves: 100 % HP Hydraulic Spring Loaded Bypass with Safety Function (two valves) 100 % +16,5 % RH Hydraulic Spring Loaded Safety Valve (two valves) The arrangement is shown schematic on in Figure 20. This arrangement secures that sufficient flow through the reheater will be available. The RH safety valves will be designed for 100 % flow from the HP part plus a spray water flow of e.g. 16,5%. The span between normal operation pressure at MCR 103% and the set pressure of the safety valves can be used for overload operation. By having combined HP bypass and HP safety salves, the whole span can be used. It is normally foreseen that the LP bypass valves at the turbine will have a capacity of 60-70%. At turbine trip the RH safety valves will open and the boiler load will be reduced down to % load. When the RH safety valves close the full RH flow will pass through the LP bypass valves OPERATIONAL MODES The controlled HP bypass and the RH safety valves can be designed and programmed for three types of operation: Safety Relief (opening time < 2 s) Quick Opening (opening & closing time 5 s) Control Operation (opening & closing time s) Figure 20 Schematic arrangement of HP Bypass & RH Safety Valves. The Safety Relief control unit will open the valves at the set pressure as if they were simple spring loaded safety valves. The hydraulic relief system is in line with EN The Quick Opening function relieves the pressure at low load and part load when the sliding pressure is exceeded by a certain margin. In this way the quick opening function avoids stagnation in the steam flow in the superheaters and reheaters which is essential for the sufficient cooling.

24 The Control Operation mode is used for pressure and flow control during start up conditions. By continuous boiler operation after a turbine trip, the HP bypass valves are used to control the boiler pressure and follows the sliding pressure curve. The safety valve design described is in line with the references of BWE and in line with the design of USC Boilers in Northern Europe PIPE LAYOUT As a consequence of CSPRS the pipe layout will be simplified due to a reduced number of safety, bypass and vent valves. The amount of piping on a 660 MWe unit will thus be reduced by approximately 50 tons of P92 material and in addition 6 large tee pieces. The HP bypass valves are connected closely to the main steam line and in this way kept at sufficient temperature. The two HP bypass valves will always operate in parallel avoiding temperature imbalances between the left and the right side of the boiler outlet. The RH safety valves will be equipped with exhaust pipes and silencers. Only the RH safety valves require a small bore heating line. Figure 21 Layout HP piping Porto Tolle MWe. 13 APH SEALING SYSTEM The introduction of a SCR plant increases the overall pressure drop and hence increases the pressure difference between the air side and flue gas side. This will entail a larger air leakage and as a consequence reduce the plant efficiency and net production. Today requirements for quick load changes and frequent start and stop have increased the benefits of having flexible and automatic systems which ensures optimum leakage conditions under all loads SEALING SYSTEMS Reduced APH leakage is thus vital for a proper and efficient operation of the boiler. A first step is to choose the single train and mono component concept in new designs as described in Section 9.5 and Figure 15. Another and just as important step is to install Advanced Sealing Systems.

25 The Advanced Sealing System can be divided into the following main groups: Sealing systems between the air and flue gas sides. These systems are the radial sealing system and the axial sealing system. The bypass sealing. The circumferential sealing system prevents the air and flue gases from bypassing the rotor on the outside. Sealing to the outside. The shaft sealing system, i.e. rotor drive seals and soot blower seals, prevents flue gas and air from leaking to the atmosphere. As direct leakage is proportional to the square root of the pressure difference between air and flue gas sides doubling the number radial walls makes possible to obtain a 30% reduction of the leakage ACTIVE LEAKAGE CONTROL SYSTEM The primary sealing system is the radial sealing system that is formed by labyrinth seals between the radial sealing plates and the rotor. The sealing system prevents leakage from the air sides to the flue gas side. Radial sealing plates are installed at the top between the rotor and the top sector beam and at the bottom between the rotor and the bottom sector beam. Figure 22 Principle for APH Sealing System with Active Leakage Control System at top and bottom (Left Cold, Right Hot). For small to medium size APH the radial sealing plates are typically kept as one section. For larger size APH the radial sealing plates are divided into more sections to ensure an optimum adaptation to the thermal deflection of the rotor along the entire rotor diameter. Because of the temperature difference from top to bottom, the rotor will deflect due to the enhanced thermal expansion of the upper parts. With Active Leakage Control System it is ensured that the radial seal plates follow the thermal deflection and thereby reduces the leakage to minimum independent on the boiler load. The displacement of the radial seal plates is controlled by an Active Leakage Control System which keeps the radial seal plates at a constant distance

26 Figure 22 shows a cross sectional of the APH and the function of the Active Leakage Control System at both top and bottom. Left side shows the rotor and sealing system in cold condition and right side shows the rotor and sealing system in normal operating position SEAL GAP SENSOR The gap between the radial seal plate and the APH rotor is measured by a Seal Gap Sensor. Action is taken to correct any deviation from the desired distance and each radial seal is controlled individually. BWE has developed a reliable Seal Gap Sensor that is temperature resistant continuously up to 420 C and can be installed in hot flue gas condition without external cooling. The Active Leakage Control System and Seal Gap Sensors are installed in APH and GGH at new power plants and retrofitted into a number of existing boilers including. Below a few operational plants. APH & GGH References Place Name Country Type Kind Year Maja India APH NEW 2015 Hazira India APH NEW 2012 Enna Italy 2012 APH NEW 2012 Staudinger Unit 5 Germany APH REHAB 2012 Brindisi South Unit 4 Italy APH REHAB 2012 Fusina Unit 3 Italy APH REHAB 2010 Torrevaldaliga North Italy APH REHAB 2010 Amager Unit 3 Denmark APH NEW 2008 Fyn Unit 7 Denmark APH REHAB 2007 Litoral de Almeira Spain GGH NEW 2015 Puk-Pyeong Sourth Korea GGH NEW 2015 Taean Sourth Korea GGH NEW 2015 Dangjin Sourth Korea GGH NEW 2014 Gumi Sourth Korea GGH NEW 2012 Jorf Lasfar Marocco GGH NEW 2012 Honam Sourth Korea GGH NEW 2012 Figure 23 BWE Seal Gab Sensor for APH Active Leakage Control System. Figure 24 APH & GGH Operational Plant

27 14 FUTURE ADVANCED BOILER DESIGN The next step in advanced boiler design is to increase steam parameter further. Studies performed in the late 1990 s proved that an increase of steam temperatures to 650 C is not possible with the martensitic steel P91 & P92. Instead the use of nickel alloy materials as alloy 174, 263, 617 and 740 is required. Since these materials are not limited by creep below 650 C, it seems natural to take a large step up to 700 C steam temperature. Some of the relevant materials were tested under the COMTES700 program. Test results of the manufacturing and operational test showed that machining, bending and welding of high nickel alloy materials were highly challenging. Also cracks appeared in welding of thick walled components and internally in valves, like excessive corrosion were observed on the certain superheater sections. Figure 25 Effect of Steam Conditions on Cycle Efficiency (Single Reheat). Source: Advanced Power Plant Using High Efficiency Boiler/Turbine, 2006 The COMTES700 project concluded that there are still many technical challenges to overcome before a 700 C boiler can be operated reliably. Technically a 700 C boiler design is therefore presently not realistic. Commercially it seems more attractive to improve the present known USC design based on the 600/610 C boiler concept. On short term aiming at 50 % plant efficiency by use of low mass flux vertical evaporator tubing, double reheat and flue gas heat transfer system (condensate and feed water heating by further flue gas cooling) seems more feasible. 15 CONCLUSION (BAT) The use of BAT (Best Available Technology) is becoming a political demand. BAT conclusions stating the achievable emission limits and efficiency will become benchmark for the power industry. With BWE technology it is proven that USC Boilers can be operated with steam

Modern boiler design. by Flemming Skovgaard Nielsen, BWE Paolo Danesi, BWE M.V.Radhakrishnan, BWE Energy India

Modern boiler design. by Flemming Skovgaard Nielsen, BWE Paolo Danesi, BWE M.V.Radhakrishnan, BWE Energy India Modern boiler design by Flemming Skovgaard Nielsen, BWE Paolo Danesi, BWE M.V.Radhakrishnan, BWE Energy India January 2012 Contents Modern boiler design 2012 1. Abstract... 3 2. Introduction... 4 3. Tower

More information

912 MW Supercritical Boiler for the next Coal Fired Plant Generation

912 MW Supercritical Boiler for the next Coal Fired Plant Generation 912 MW Supercritical Boiler for the next Coal Fired Plant Generation Konrad Ebert, Dr. Michael Kübel (1) Heinz Lorey, Wolfgang Michele (2) (1) EnBW Kraftwerke AG, Stuttgart/Germany (2) ALSTOM Boiler Deutschland

More information

Efficiency on a large scale CFB Steam Boilers

Efficiency on a large scale CFB Steam Boilers Efficiency on a large scale CFB Steam Boilers Circulating Fluidized Bed Steam Boiler The Circulating Fluidized Bed Steam Boiler is an offering from Bosch Thermotechnology a member of the worldwide Bosch

More information

A Review on Power Generation in Thermal Power Plant for Maximum Efficiency

A Review on Power Generation in Thermal Power Plant for Maximum Efficiency International Journal of Advanced Mechanical Engineering. ISSN 2250-3234 Volume 4, Number 1 (2014), pp. 1-8 Research India Publications http://www.ripublication.com/ijame.htm A Review on Power Generation

More information

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district PLANT TORINO NORD Iren Energia is the company in the Iren Group whose core businesses are the production and distribution of electricity, the production and distribution of thermal energy for district

More information

OROT RABIN POWER STATION UNITS 1-4. 4 x 350 MW

OROT RABIN POWER STATION UNITS 1-4. 4 x 350 MW ISRAEL ELECTRIC OROT RABIN POWER STATION UNITS 1-4 4 x 350 MW COAL BOILER CONVERSION TO LOW NO X NATURAL GAS AND COAL FIRING BY PRIMARY AND SECONDARY MEASURES INSTALLATION Replacing the Burner Management

More information

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2 WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials

More information

Committed to make a better world

Committed to make a better world Committed to make a better world 1. Higher Availability & Reliability 2. Highest Plant efficiency 3. Lower Heat Rate 4. Minimum Auxiliary Power Consumption 5. Minimum Emission of Pollutants Committed to

More information

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin Drying of Woody Biomass BioPro Expo & Marketplace / Atlanta, GA / March 14-16, 2011 Drying of Woody Biomass Conventional Direct Fired Dryer Technology Proprietary work of the Copyright Owner Issues with

More information

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace Content 1. Technical overview cogeneration plant and heating network 2. Investment of the facility 3. Experiences

More information

Best Choice BENSON BOILER. Excellent performance features make the Benson boiler the most widely used type of once-through boiler

Best Choice BENSON BOILER. Excellent performance features make the Benson boiler the most widely used type of once-through boiler BENSON BOILER Best Choice Excellent performance features make the Benson boiler the most widely used type of once-through boiler by JOACHIM FRANKE and RUDOLF KRAL Power for generations BENSON BOILER Best

More information

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 8, Issue 6 (Sep. - Oct. 2013), PP 25-29 Performance of the Boiler and To Improving the Boiler Efficiency

More information

NAWTEC18-3541 CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY

NAWTEC18-3541 CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY Proceedings of the 18th Annual North American Waste-to-Energy Conference NAWTEC18 May 11-13, 2010, Orlando, Florida, USA NAWTEC18-3541 CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED

More information

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla Helsinki University of Technology Department of Mechanical Engineering Energy Engineering and Environmental Protection Publications Steam Boiler Technology ebook Espoo 2002 Boiler Calculations Sebastian

More information

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain

More information

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley. Sample Questions REVISED FIRST CLASS PARTS A1, A2, AND A3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations. They are not intended as study

More information

RELIABLE AND EFFICIENT STEAM GENERATION SYSTEMS FOR MODERN UTILITY SERVICE

RELIABLE AND EFFICIENT STEAM GENERATION SYSTEMS FOR MODERN UTILITY SERVICE RELIABLE AND EFFICIENT STEAM GENERATION SYSTEMS FOR MODERN UTILITY SERVICE The safe, reliable and efficient generation of steam has challenged boiler designers since steam was first harnessed for power.

More information

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design BRYAN FLEXIBLE WATER TUBE AB SERIES STEAM AND WATER BOILER 900,000 TO 3,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler AB120-W-FDGO Steam Boiler AB250-S-150-FDG Originators of the Flexible

More information

Design and Operating Experience of the Latest 1,000-MW Coal-Fired Boiler

Design and Operating Experience of the Latest 1,000-MW Coal-Fired Boiler Hitachi Review Vol. 47 (1998), No. 5 183 Design and Operating Experience of the Latest 1,000-MW Coal-Fired Boiler Kazuhito Sakai Shigeki Morita Tsutomu Yamamoto Toshikazu Tsumura ABSTRACT: The Matsuura

More information

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler [N.2.1.1] R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler (Environment-Friendly, High-Efficiency Boiler Group) Takashi Murakawa, Yasuhiro Kotani, Kazuhiro Kamijo, Koichi Tsujimoto, Hiroshi

More information

5.2. Vaporizers - Types and Usage

5.2. Vaporizers - Types and Usage 5.2. Vaporizers - Types and Usage 5.2.1. General Vaporizers are constructed in numerous designs and operated in many modes. Depending upon the service application the design, construction, inspection,

More information

Pulverized Coal Pipe Testing and Balancing

Pulverized Coal Pipe Testing and Balancing Pulverized Coal Pipe Testing and Balancing By Richard F. (Dick) Storm, PE The first step in optimizing combustion system performance is balancing the air and fuel flowing through each of the plant's coal

More information

The soot and scale problems

The soot and scale problems Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications

More information

Natural Gas Conversions of Existing Coal-Fired Boilers

Natural Gas Conversions of Existing Coal-Fired Boilers White Paper MS-14 Natural Gas Conversions of Existing Coal-Fired s Authors: F.J. Binkiewicz Jr., P.E. R.J. Kleisley B.E. McMahon J.E. Monacelli D.A. Roth D.K. Wong Babcock & Wilcox Power Generation Group,

More information

Progress on High Efficiency Coal Power Plants

Progress on High Efficiency Coal Power Plants CoalFleet for Tomorrow Progress on High Efficiency Coal Power Plants Dr. Jeff Phillips Sr. Program Manager, Generation McIlvaine Webcast March 1, 2012 CoalFleet for Tomorrow is a registered service mark

More information

SIMPLIFIED BOILER START UP METHOD FOR FLUIDISED BED COMBUSTION BOILERS

SIMPLIFIED BOILER START UP METHOD FOR FLUIDISED BED COMBUSTION BOILERS SIMPLIFIED BOILER START UP METHOD FOR FLUIDISED BED COMBUSTION BOILERS 1.0 SYNOPSIS The start up of fluidised bed combustion boilers has always been a subject of the most difficult operation. Many boiler

More information

Skoda Supercritical Steam Turbine 660 MW

Skoda Supercritical Steam Turbine 660 MW Skoda Supercritical Steam Turbine 660 MW Jiri Fiala Head of Engineering Dept. Skoda Power s.r.o. 27th of October 2010 Vrnjacka Banja - Serbia ŠKODA History Establishment of the company in 1859 Mr. Emil

More information

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours: Current state of plant Functioning as a peak and emergency centre Statistics Accumulated operating hours: D1-2-3-6-7: 43000 to 48000 hrs D4-5: 53000 to 57000 hrs D8: 33000 hrs Layout of the plant Index:

More information

Enhanced power and heat generation from biomass and municipal waste. Torsten Strand. Siemens Power Generation Industrial Applications

Enhanced power and heat generation from biomass and municipal waste. Torsten Strand. Siemens Power Generation Industrial Applications Enhanced power and heat generation from biomass and municipal waste Torsten Strand Siemens Power Generation Industrial Applications Enhanced power and heat generation from biomass and municipal waste Torsten

More information

Operational Flexibility Enhancements of Combined Cycle Power Plants. Dr. Norbert Henkel, Erich Schmid and Edwin Gobrecht

Operational Flexibility Enhancements of Combined Cycle Power Plants. Dr. Norbert Henkel, Erich Schmid and Edwin Gobrecht Operational Flexibility Enhancements of Combined Cycle Power Plants Dr. Norbert Henkel, Erich Schmid and Edwin Gobrecht Siemens AG, Energy Sector Germany POWER-GEN Asia 2008 Kuala Lumpur, Malaysia October

More information

Stora Enso Fors Ltd Sweden

Stora Enso Fors Ltd Sweden THE ANALYSIS REPORT OF PLANT NO. 3 Cofiring of biomass - evaluation of fuel procurement and handling in selected existing plants and exchange of information (COFIRING) - Part 2 Stora Enso Fors Ltd Sweden

More information

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal. 413 POWER PLANT ENGINEERING PART-A 1. Define Power. Power is the rate at which energy is used (or) Energy/time. 2. What are the types of fuels? Solid fuel Liquid fuel Gaseous fuel (Any one among the above

More information

Continuous flow direct water heating for potable hot water

Continuous flow direct water heating for potable hot water Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial

More information

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3 HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- BY MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3 SYNOPSIS JP Steel Plantech Co. has developed Hybrid system for EAF off-gas heat recovery, with EAF

More information

INTEC Engineering GmbH Heating Solutions for the Marine Industry

INTEC Engineering GmbH Heating Solutions for the Marine Industry INTEC Engineering GmbH Heating Solutions for the Marine Industry Thermal Oil Heaters Heating Solutions for the Marine Industry Compared to conventional plants using hot water or steam, thermal oil as a

More information

Chapter 3.5: Fans and Blowers

Chapter 3.5: Fans and Blowers Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist

More information

SRS: THE STANDARDIZED REPOWERING SOLUTION FOR 300MW STEAM POWER PLANTS IN RUSSIA. Matthias Fränkle Siemens Power Generation (PG), Germany

SRS: THE STANDARDIZED REPOWERING SOLUTION FOR 300MW STEAM POWER PLANTS IN RUSSIA. Matthias Fränkle Siemens Power Generation (PG), Germany SRS: THE STANDARDIZED REPOWERING SOLUTION FOR 300MW STEAM POWER PLANTS IN RUSSIA Matthias Fränkle Siemens Power Generation (PG), Germany Page 1 of 11 1 Introduction Deregulation and competition are further

More information

Marine after-treatment from STT Emtec AB

Marine after-treatment from STT Emtec AB Marine after-treatment from STT Emtec AB For Your Vessel and the Environment 6 7 8 1 11 1 10 9 1. Pick up. Flow direction valve. Filters. Cooler. Condensate trap 6. Flow meter 7. EGR-valve 8. Secondary

More information

1 DESCRIPTION OF THE APPLIANCE

1 DESCRIPTION OF THE APPLIANCE 1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers

More information

By K.K.Parthiban / Boiler specialist / Venus Energy Audit System

By K.K.Parthiban / Boiler specialist / Venus Energy Audit System FINE TUNING EXPERIENCE OF A CFBC BOILER By K.K.Parthiban / Boiler specialist / Venus Energy Audit System Introduction The Industrial boilers have been seeing a growth in capacity in the recent years. Current

More information

2nd IEA Oxyfuel Combustion Conference

2nd IEA Oxyfuel Combustion Conference 2nd IEA Oxyfuel Combustion Conference Oxyfuel Combustion with Hitachi's DST - Burner at Vattenfall's 30Wth Pilot Plant at Schwarze Pumpe S. Rehfeldt, F.-P. Schiffer, P. Weckes, C. Bergins, K.-D. Tigges

More information

BIOPOWER 5 CEX. 1 Wärtsilä 10 January 2012 Presentation name / Author

BIOPOWER 5 CEX. 1 Wärtsilä 10 January 2012 Presentation name / Author BIOPOWER 5 CEX 1 Wärtsilä 10 January 2012 Presentation name / Author GENERAL INFORMATION ELECTRICAL OUTPUT 4.3 5.5 MWe HEAT OUTPUT Up to 10 MWth (16 t/h steam 1,3 bara) FUEL TYPE Wood chips, bark, saw

More information

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY Biomass Boiler House Best Practices Irene Coyle & Fernando Preto CanmetENERGY Growing the Margins London, Ontario March 2010 The Biomass & Renewables Group of Industrial Innovation Group (IIG) of CanmetENERGY

More information

Development and Operating Results of Low SO2 to SO3 Conversion Rate Catalyst for DeNOx Application

Development and Operating Results of Low SO2 to SO3 Conversion Rate Catalyst for DeNOx Application Development and Operating Results of Low SO2 to SO3 Conversion Rate Catalyst for DeNOx Application By Isato Morita Yoshinori Nagai Dr. Yasuyoshi Kato Babcock-Hitachi K.K., Japan Dr.Howard N. Franklin Hitachi

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Waste Incineration Plants

Waste Incineration Plants Waste Incineration Plants Modern Technology for a better Environmental Welcome at Hafner! We Manufacture Systems for Energy Recovery from Wastes and Biomass as well as for Treatment of Hazardous Wastes.

More information

North American Stainless

North American Stainless Introduction: North American Stainless Flat Products Stainless Steel Grade Sheet 309S (S30908)/ EN1.4833 SS309 is a highly alloyed austenitic stainless steel used for its excellent oxidation resistance,

More information

Energy Efficient Operations and Maintenance Strategies for Boilers

Energy Efficient Operations and Maintenance Strategies for Boilers Energy Efficient Operations and Maintenance Strategies for Boilers Large, complex and widely used, industrial boilers are major consumers of fuel. Proper operations and maintenance (O&M) procedures must

More information

Experience with co-combustion of biomass and waste in coal-fired power plants

Experience with co-combustion of biomass and waste in coal-fired power plants Experience with co-combustion of biomass and waste in coal-fired power plants Topsøe Catalysis Forum August 2009 Bo Sander, DONG Energy Power, Denmark GENERATION - HCASA DONG Energy Power in Europe Power

More information

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS Dr. Abhay Kumar Sahay, AGM(CC OS) Bijay Manjul, AGM( Operation) Kahalgaon Boiler has three inputs Steam generator 1. WATER 2. COAL 3. AIR Burner Air preheater

More information

North American Stainless

North American Stainless North American Stainless Flat Products Stainless Steel Grade Sheet 310S (S31008)/ EN 1.4845 Introduction: SS310 is a highly alloyed austenitic stainless steel designed for elevated-temperature service.

More information

ANCILLARY SERVICES SUPPLIED TO THE GRID: THE CASE OF THISVI CCGT POWER PLANT (GREECE)

ANCILLARY SERVICES SUPPLIED TO THE GRID: THE CASE OF THISVI CCGT POWER PLANT (GREECE) Claudio Cavandoli, Alessandro Crippa EDISON S.p.A., Engineering Department ANCILLARY SERVICES SUPPLIED TO THE GRID: THE CASE OF THISVI CCGT POWER PLANT (GREECE) 1 ANCILLARY SERVICES SUPPLIED TO THE GRID:

More information

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance

More information

GAS COOLING SYSTEMS FOR STEAM REFORMING PLANTS

GAS COOLING SYSTEMS FOR STEAM REFORMING PLANTS GAS COOLING SYSTEMS FOR STEAM REFORMING PLANTS 1 1.1 INTRODUCTION is a leading and highly regarded supplier of components and systems for the petrochemical, chemical, refining & metallurgical industries.

More information

1.3 Properties of Coal

1.3 Properties of Coal 1.3 Properties of Classification is classified into three major types namely anthracite, bituminous, and lignite. However there is no clear demarcation between them and coal is also further classified

More information

EFFICIENT ENERGY SUPPLY (ELECTRICITY AND DISTRICT HEAT) FOR THE CITY OF LINZ

EFFICIENT ENERGY SUPPLY (ELECTRICITY AND DISTRICT HEAT) FOR THE CITY OF LINZ Parallel session Producing more with less: Efficiency in Power Generation EFFICIENT ENERGY SUPPLY (ELECTRICITY AND DISTRICT HEAT) FOR THE CITY OF LINZ Johann Gimmelsberger Linz Strom GmbH EFFICIENT ENERGY

More information

ENERGY EFFICIENCY IN POWER PLANTS

ENERGY EFFICIENCY IN POWER PLANTS Plenary session Producing more with less: Efficiency in Power Generation ENERGY EFFICIENCY IN POWER PLANTS Frans van Aart, Wim Kok, Pierre Ploumen KEMA Power Generation & Sustainables ENERGY EFFICIENCY

More information

Cofiring of biomass in coal-fired power plants European experience Dr Colin Henderson IEA Clean Coal Centre

Cofiring of biomass in coal-fired power plants European experience Dr Colin Henderson IEA Clean Coal Centre Cofiring of biomass in coal-fired power plants European experience Dr Colin Henderson IEA Clean Coal Centre Presentation at FCO/IEA CCC workshops on policy and investment frameworks to introduce CCT in

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 24 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia S TABLE OF CONTENT SCOPE 2 DEFINITIONS

More information

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation Steam Generator Boilers Compact Steam Boilers Rapid Start-Up Safe in Operation AB&CO TT BOILERS The boiler maker AB&CO TT BOILERS LTD. have since the middle sixties produced industrial boilers and heaters

More information

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50

More information

Webpage: www.ijaret.org Volume 3, Issue IV, April 2015 ISSN 2320-6802

Webpage: www.ijaret.org Volume 3, Issue IV, April 2015 ISSN 2320-6802 Efficiency Assessment and Improvement of at Super Thermal Power Station Vikram Singh Meena 1, Dr. M.P Singh 2 1 M.Tech in Production Engineering, Jagannath University, Jaipur, Rajasthan, India Vikrammeena134@gmail.com

More information

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International Presentation Overview Water Heater Piping Strategies How to size a water heater?

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Latest Low-NOx Combustion Technology for Pulverized-coal-fired Boilers

Latest Low-NOx Combustion Technology for Pulverized-coal-fired Boilers Hitachi Review Vol. 58 (29), No.5 187 Latest Low- Combustion Technology for Pulverized-coal-fired Boilers Kenichi Ochi Kenji Kiyama Hidehisa Yoshizako, Dr. Eng. Hirofumi Okazaki Masayuki Taniguchi, Dr.

More information

IMPROVING BOILER EFFICIENCY BY USING AIR PREHEATER

IMPROVING BOILER EFFICIENCY BY USING AIR PREHEATER V. Mallikarjuna* N. Jashuva** International Journal of Advanced Research in IMPROVING BOILER EFFICIENCY BY USING AIR PREHEATER B. Rama Bhupal Reddy*** Abstract: Air pre-heater is a heat transfer surface

More information

Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance

Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance The Boiler MACT, 40 CFR 63, Subpart DDDDD, was vacated in 2007 by the U.S Court of Appeals and the 2004 rule

More information

Completion of SCR System for Ninghai Power Plant Unit 4 in China

Completion of SCR System for Ninghai Power Plant Unit 4 in China Hitachi Review Vol. 57 (2008), No. 6 293 Completion of SCR System for Ninghai Power Plant 4 in China Yoshiro Inatsune Yoshiyuki Takeuchi Masafumi Ishizaki OVERVIEW: The SCR system installed on Ninghai

More information

Alstom Development of Oxyfuel PC and CFB Power Plants

Alstom Development of Oxyfuel PC and CFB Power Plants Alstom Development of Oxyfuel PC and CFB Power Plants Frank Kluger & John Marion 3 rd Oxy-Combustion Workshop Yokohama, Japan March 06, 2008 Improvement Measures for Fossil Power Plants Regarding CO2 Mitigation

More information

OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS

OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS CONFERENCE PROCEEDINGS OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS by Edward K. Levy, Nenad Sarunac, and Carlos Romero Energy

More information

Marine after-treatment from STT Emtec AB

Marine after-treatment from STT Emtec AB Marine after-treatment from STT Emtec AB For Your Vessel and the Environment SCR Technology How it works The selective catalytic reduction of nitrous oxides (NOx) by nitrogen compounds such as urea solutions

More information

Boiler Preparation, Start-Up and Shutdown

Boiler Preparation, Start-Up and Shutdown Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.

More information

Session 2: Hot Water Supply

Session 2: Hot Water Supply MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

Vogt Power Emission Control Solutions

Vogt Power Emission Control Solutions ONE SOURCE ONE PURPOSE MANY SOLUTIONS Vogt Power Emission Control Solutions Kelly Flannery Kristen Cooper Andrew Heid Chief Thermal Engineer Simple Cycle Design Lead Emission Catalyst Design Lead Presented

More information

VAD Variable Area Desuperheaters

VAD Variable Area Desuperheaters Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Thermodynamical aspects of the passage to hybrid nuclear power plants

Thermodynamical aspects of the passage to hybrid nuclear power plants Energy Production and Management in the 21st Century, Vol. 1 273 Thermodynamical aspects of the passage to hybrid nuclear power plants A. Zaryankin, A. Rogalev & I. Komarov Moscow Power Engineering Institute,

More information

Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers

Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers 192 Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers Masayuki Hirano Yasuyoshi Kato

More information

Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology

Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology Combustion Technology INNOVATIVE SOLUTIONS FOR COMBUSTION AND EMISSIONS CHALLENGES Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems Callidus Technologies by Honeywell - Experie

More information

Advanced Steam Parameters in a Large Scale CFB Application Operating on REF and Biofuels background and experiences

Advanced Steam Parameters in a Large Scale CFB Application Operating on REF and Biofuels background and experiences Advanced Steam Parameters in a Large Scale CFB Application Operating on REF and Biofuels background and experiences Matts Strömberg Soderenergi AB, Sweden Presented at Power Gen Europe 2011 Milan, Italy

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

IMPROVING ENERGY EFFICIENCY IN CEMENT PLANTS

IMPROVING ENERGY EFFICIENCY IN CEMENT PLANTS IMPROVING ENERGY EFFICIENCY IN CEMENT PLANTS USING COMPUTATIONAL FLUID DYNAMICS (CFD) For Bureau of Energy Efficiency Best Practices in Energy Efficiency in Cement Sector" Date : 23 rd June 2015 Jodhpur,

More information

GENERAL PROPERTIES //////////////////////////////////////////////////////

GENERAL PROPERTIES ////////////////////////////////////////////////////// ALLOY 625 DATA SHEET //// Alloy 625 (UNS designation N06625) is a nickel-chromium-molybdenum alloy possessing excellent resistance to oxidation and corrosion over a broad range of corrosive conditions,

More information

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine.

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine. EXPERIMENT NO. 3 Aim: To study the construction and working of 4- stroke petrol / diesel engine. Theory: A machine or device which derives heat from the combustion of fuel and converts part of this energy

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Boiler efficiency measurement. Department of Energy Engineering

Boiler efficiency measurement. Department of Energy Engineering Boiler efficiency measurement Department of Energy Engineering Contents Heat balance on boilers Efficiency determination Loss categories Fluegas condensation principals Seasonal efficiency Emission evaluation

More information

Tutkimuksen merkitys menestyvässä liiketoiminnassa- Innovaatiosta tuotteeksi

Tutkimuksen merkitys menestyvässä liiketoiminnassa- Innovaatiosta tuotteeksi Tutkimuksen merkitys menestyvässä liiketoiminnassa- Innovaatiosta tuotteeksi Matti Rautanen Manager, External Networks, Power-wide R&D Tutkimuksella tulevaisuuteen- seminaari Kaukolämpöpäivät, Kuopio 29.8.2013

More information

I. STEAM GENERATION, BOILER TYPES

I. STEAM GENERATION, BOILER TYPES I. STEAM GENERATION, BOILER TYPES and BOILER PLANT SYSTEMS 1 Steam Generation Water s Unique Properties: High Thermal Capacity (Specific Heat) High Critical Temperature Ideal Medium for Heat Delivery High

More information

Optimal Power Plant Integration of Post-Combustion CO 2 Capture. Dr. Tobias Jockenhövel Dr. Rüdiger Schneider Michael Sandell Lars Schlüter

Optimal Power Plant Integration of Post-Combustion CO 2 Capture. Dr. Tobias Jockenhövel Dr. Rüdiger Schneider Michael Sandell Lars Schlüter Optimal Power Plant Integration of Post-Combustion CO 2 Capture Dr. Tobias Jockenhövel Dr. Rüdiger Schneider Michael Sandell Lars Schlüter Siemens AG, Energy Sector Germany POWER-GEN Europe 2009 Cologne,

More information

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN Application 1 The first step in selecting an industrial oven is defining the required heat application that your oven will be used for. Heat processing is extensively

More information

Online Infrared Flue Gas Analyzer Gasboard 3000

Online Infrared Flue Gas Analyzer Gasboard 3000 Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume

More information

Heat Exchangers in Boilers

Heat Exchangers in Boilers Helsinki University of Technology Department of Mechanical Engineering Energy Engineering and Environmental Protection Publications Steam Boiler Technology ebook Espoo 2002 Heat Exchangers in Boilers Sebastian

More information

VAD. Variable Area Desuperheaters

VAD. Variable Area Desuperheaters Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated

More information

THE OPTIMISATION OF BIOMASS COMBUSTION IN SMALL BOILERS

THE OPTIMISATION OF BIOMASS COMBUSTION IN SMALL BOILERS The optimisation of biomass INFRASTRUKTURA I EKOLOGIA TERENÓW WIEJSKICH INFRASTRUCTURE AND ECOLOGY OF RURAL AREAS Nr 6/28, POLSKA AKADEMIA NAUK, Oddział w Krakowie, s. 63 69 Komisja Technicznej Infrastruktury

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

University of Iowa Power Plant

University of Iowa Power Plant University of Iowa Power Plant Contents Purpose... 2 History... 3 Cogeneration... 6 Boilers... 7 Environmental Impact... 10 Steam Turbine Generators... 12 Modernization... 14 Biomass Fuel Initiative...

More information

AE BIO SOLAR AE BIO SOLAR HYBRID PLANT SOLAR/BIOMASS ADESSO ENERGIA SRL HYBRID PLANT SOLAR/BIOMASS THE BEGINNING OF A NEW ENERGY PRESENTATION

AE BIO SOLAR AE BIO SOLAR HYBRID PLANT SOLAR/BIOMASS ADESSO ENERGIA SRL HYBRID PLANT SOLAR/BIOMASS THE BEGINNING OF A NEW ENERGY PRESENTATION ADESSO ENERGIA SRL AE BIO SOLAR THE BEGINNING OF A NEW ENERGY PRESENTATION Tel.0918887364 14.05.2014 fax 0917480735 Pagina 1 INTRODUCTION Adesso Energia is an innovative startup based in Palermo created

More information

IMPROVING COAL PLANT EFFICIENCY

IMPROVING COAL PLANT EFFICIENCY IMPROVING COAL PLANT EFFICIENCY Some ideas to consider for existing coal units to Work Toward Compliance with the EPA Clean Power Plan, Rule 111d Coal Plant Efficiency Improvements Presentation by: Dick

More information