1 J.T.Baker CYCLE-TAINER Solvent Delivery System Plumbing and Piping guide Phillipsburg, NJ 9001:2008 & 14001:2004 Paris, KY 9001:2008 Mexico City, Mexico 9001:2008 Deventer, the Netherlands 9001:2008, 14001:2004 & 13485:2003 Gliwice, Poland 9001:2008 & 17025:2005 Selangor, Malaysia 9001:2008 Dehradun, India 9001:2008, 14001:2004 & 13485:2003 Mumbai, India 9001:2008 & 17025:2005 Avantor Performance Materials Avantor Performance Materials manufactures and markets high-performance chemistries and materials around the world under several respected brand names, including the J.T.Baker, Macron Fine Chemicals, Rankem, BeneSphera and POCH brands. Avantor products are used in a wide range of industries. Our biomedical and life science solutions are used in academic, industry and quality control laboratories for research, pharmaceutical production and medical lab testing, while our electronics solutions are used in the manufacturing of semiconductors. For additional information please visit or follow Ordering Information and Assistance Customer Service tel: AVANTOR ( ) fax: info@avantormaterials.com ASK Avantor Our Web site features ASK Avantor, which includes live chat capabilities with customer service representatives. Corporate Headquarters Avantor Performance Materials, Inc Corporate Parkway Suite #200 Center Valley, PA USA Worldwide Locations China Malaysia North America India Mexico Poland Korea The Netherlands Taiwan For contact information at these locations, visit Lit # 9144 V Avantor Performance Materials, Inc. All rights reserved. Trademarks are owned by Avantor Performance Materials, Inc. or its affiliates unless otherwise noted.
2 Contents Warnings and Cautions...2 Introduction...3 Typical Parts used in CYCLE-TAINER System Installations...4 System Start-up Considerations...5 Engineering Drawings for CYCLE-TAINER System Installations...6 Installation Showing Remote Container Storage and Multiple Points of Use...6 Direct Feed to Small Process or Analytical Instrument...7 References...8 1
3 Warnings and Cautions Please read carefully and observe the information and/or directives in these statements. See below for an explanation of these statements. CAUTION Statements will indicate potentially hazardous operating procedures. WARNING Statements will highlight regulatory requirements. CAUTION: Do not pressurize the container with compressed air or oxygen. Failure to observe this caution could result in an explosive situation, which can cause severe injuries to personnel. CAUTION: Check the weight restrictions for your forklift or hand-operated fork truck before moving the CYCLE-TAINER system. Most lifting equipment is designed to lift up to a designated weight. WARNING: Local regulatory agencies, building codes, and safety policies may require that you attach the container to vent lines during operation. The vent lines attach to the Pressure Relief Valve (PRV) and the Pressure Rupture Disk (PRDA) (if applicable). CAUTION: When direct feeding to instrumentation and when applicable, the setup should have its main solvent supply valve closed to prevent unintentional solvent surges or down-line releases when the CYCLE-TAINER system is pressurized. CAUTION: All metal supply and distribution lines should be electrically earth grounded. Storage areas must provide electrical earth ground connections for all containers while in use. CAUTION: Ensure your gas supply is routed through a high quality stainless steel pressure regulator. The regulator output pressure must not exceed 40 psig for ASME-certified containers; 15 psig for non-asme certified containers; 5 psig for 1250 L containers manufactured prior to October 1998; 19 psig for 1250 L containers manufactured after October These pressures represent maximum working pressures of the CYCLE-TAINER systems. CAUTION: To avoid possible ignition or explosion to toxic/ flammable vapors, we recommend the pressure relief output be directed to a hood or other proper venting location. If an external vent line is used, ensure it does not restrict gas flow from the pressure relief device or create a vacuum against the pressure relief device. Introduction After selecting a solvent dispensing method using the CYCLE-TAINER Solvent Delivery System Dispensing Guide, the next step is to consider the location of the CYCLE-TAINER system within your facility. This document will provide guidance on components to complete the CYCLE-TAINER system installation. Your company safety officer is responsible for ensuring compliance with local fire and building codes and National Fire Protection Association (NFPA) codes, particularly NFPA 301 and NFPA 452. Some key considerations for installation include: Maximum container size allowable by local regulations, building codes, and company policies. Allowable proximity of the CYCLE-TAINER system to the point of solvent use according to local regulations, building codes, and company policies. Requirements for storage area of full and empty CYCLE-TAINER system containers according to local regulations, building codes, and company policies. Other factors to consider include: CYCLE-TAINER systems can be located next to a fume hood or analytical instrument and connected with flexible tubing. Installations using rigid, mounted tubing can enable distribution of solvent throughout your facility to multiple points of use. Page 4 describes some of the common parts needed for CYCLE-TAINER system installations. Page 6 and 7 are engineering schematics for two common CYCLE-TAINER system installations. Page 6 illustrates a remote container storage scenario with multiple dispense points. Page 7 depicts a system for a direct feed to a small process or analytical instrument. 1 National Fire Protection Agency, NFPA 30: Flammable and Combustible Liquids Code; 2012 Edition 2 National Fire Protection Agency, NFPA 45: Standard of Fire Protection for Laboratories Using Chemicals; 2011 Edition CAUTION: EXPLOSION HAZARD- You must ground the CYCLE-TAINER system during operation. CAUTION: Ensure that CYCLE-TAINER systems are secure during handling to prevent accidental loss of control of the container. This may result in injury to personnel and/or damage to the container. CAUTION: Never mount or store a container horizontally. Do not stack containers on top of each other. CAUTION: DO NOT DROP CONTAINER. This may damage the container or burst the rupture disk, rendering the container inoperable. CAUTION: When direct feeding to instrumentation, DO NOT OVERPRESSURIZE the input line to the instrument as damage to the instrument may occur. Consult the instrument manufacturer operation manual or a technical service representative for the proper feed pressure. CAUTION: Initially turn on the toggle valve slowly to release gas trapped inside the hose. When you release the lever, solvent flow will stop. WARNING: WHEN USING THE CYCLE-TAP SAMPLER, NEVER DEPRESS THE PLUNGER WHEN THE SYRINGE IS ATTACHED TO THE SAMPLER. THIS MAY INTRODUCE CONTMINANTS INTO THE CYCLE-TAINER SYSTEM. CAUTION: Do not exceed operating pressure of the CYCLE-TAINER system. WARNING: If you know or suspect that foreign substances were introduced into the container, quarantine the container and call Customer Service at AVANTOR for assistance. Do not return the container without first contacting Avantor to avoid violations of Federal and/or State laws. WARNING: Never tamper with the container components. Promptly report any container malfunctions to Customer Service at AVANTOR. ASME-certified CYCLE-TAINER system containers should be used if plumbing from distance or if higher flow rates are required. The use of dedicated hoses and tubing for each chemical product to maintain purity and quality. 2 3
4 Typical Parts used in CYCLE-TAINER System Installations Part Material of Construction Other Considerations Suggested Vendor Solvent Tubing PTFE and flexible stainless steel Minimum inner diameter of 1/2" is recommended. Consider system operating pressures when selecting tubing. Vendor Product Line or Part Number Convoluted 316L SS Core Stainless Braid Hose Convoluted PTFE Core Hose System Start-up Considerations All valves, pipes, and fittings should be degreased prior to installation. Purge all air and contamination from the piping system using solvent before first use. Test material from point of use to ensure it meets specifications before first use. Additional technical information and support for our CYCLE-TAINER System may be obtained at by using the keyword CT. Gas and Solvent Tubing PTFE Consider system operating pressures when selecting tubing. Saint Gobain Plastics 1/2 O.D., 3/8 I.D.- P/N AXH /4 O.D., 1/8 I.D.- P/N AXJ /4 O.D., 3/16 I.D.- P/N AXJ /8 O.D., 1/16 I.D.- P/N AXJ00002 Fittings Stainless steel - Gaugeable Tube Fittings and Adaper Fittings Stainless Steel Quick-Connects Tube Fittings Stainless steel - Avantor Performance Materials J.T.Baker 9809 series or consult Gaugeable Tube Fittings and Adapter Fittings catalog Quick-Connects Stainless Steel Solvent Quick-Connect bodies are keyed for specific solvents. Avantor Performance Materials J.T.Baker 9802 series (solvent) and (gas) or SS-QT2-B-4PMK series (solvent) and SS-QT2-B-4PM (gas) Solvent Valves Stainless steel and PTFE High quality diaphragm valves with PTFE stem inserts are recommended DL & DS Series High-purity, High-Pressure Diaphragm Valves Gas Supply Valves and Regulators Stainless steel with inert seals Standard industrial gas regulators and valves are not suitable for high purity solvent applications Matheson Tri-Gas High Purity Regulators and Valves 3430 Series or similar Other Parts Stainless Steel and/or PTFE Components may be dependent on end user needs. N/A N/A Thread Sealants PTFE - A.W. Chesterton Co Goldend Tape 1/2 x P/N /2 x P/N /2 x P/N
5 Engineering Drawings for CYCLE-TAINER System Installations Direct Feed to Small Process or Analytical Instrument Installation Showing Remote Container Storage and Multiple Points of Use Facility Solvent Distribution Lines 6 7
6 NOTES NOTES 8 9
COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.
Page 1 of 5 COMPRESSED GASES A compressed gas is defined as any mixture of gases in a container with a pressure exceeding 40 psi. at 70 o F, or 104 psi. at 130 o F; or any flammable liquid with an absolute
More informationCompressed Gas Cylinder Program
Department of Environmental Health & Safety Procedures Compressed Gas Cylinder Program March 2010 Compressed Gas Cylinder Program Page 1 of 8 Table of Contents I. Introduction II. III. IV. Policy Scope
More information3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:
3M Water Filtration Products Installation and Instruction Manual For: CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings Installer: Please leave this manual with owner/operator. Owner/Operator:
More informationPressure Vessels (Air Compressors) and LPG Tanks
Pressure Vessels (Air Compressors) and LPG Tanks 1. Identification of Workplace Hazard Any container, tank or vessel that contains pressurized material is a potential hazard to employees due to the force
More informationAUTOMATIC CHANGEOVER MANIFOLD Series 915
AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm
More informationNFPA31FuelOilPiping 1 Revised 3-1-11
NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from
More informationFull Technical Catalog For Closed-loop Sampling System
Full Technical Catalog For Closed-loop Sampling System Full Technical Catalog For Closed-loop Sampling System FITOK Group FITOK GmbH (Headquarter) Sprendlinger Landstr. 115, 63069 Offenbach am Main, Germany
More informationNITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
More informationMorrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
More informationROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
More informationProduct Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
More informationCompressed Gas Cylinder Storage and Handling Guide
Overview Compressed gas cylinders are used in many workplaces to store gases that vary from extremely flammable (acetylene) to extremely inert (helium). Many compressed gas cylinders are stored at extremely
More informationSAFE TRANSFER OF POWDERS INTO FLAMMABLE LIQUIDS David E. Kaelin Sr., Senior Process Safety Specialist
Hazards Control & Assess- SAFE TRANSFER OF POWDERS INTO FLAMMABLE LIQUIDS SAFE TRANSFER OF POWDERS INTO FLAMMABLE LIQUIDS David E. Kaelin Sr., Senior Process Safety Specialist A major consideration in
More informationLCT 1025 (08/08) Copyright 2008 Harleysville Mutual Insurance Company Page 1 of 5 All rights reserved
Bonding and Grounding of Flammable Liquid Containers Provided by Harleysville s Risk Control Department 800-523-6344 ext 8100 www.harleysvillegroup.com/riskcontrol Summary The movement of volatile liquids,
More informationType HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications
Instruction Manual Form 5753 Type HSR February 014 Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications P154 TYPE HSR ANGLE BODY P175 TYPE HSR STRAIGHT Figure 1.
More informationCompressed Gas Cylinder Safety
Compressed Gas Cylinder Safety I. Background. Due to the nature of gas cylinders, special storage and handling precautions are necessary. The hazards associated with compressed gases include oxygen displacement,
More informationSingle- and Two- Stage Regulators
Single- and Two- Stage Regulators English Français Español Safety and Operating Instructions Revision: D Issue Date: May 14, 2008 Form No.: 0056-1625 We appreciate your business! Congratulations on your
More informationPREPIPED LIQUID FUEL MANIFOLDS PLPM
PREPIPED LIQUID FUEL MANIFOLDS PLPM INSTRUCTIONS WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components,
More informationOxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:
I. Competencies Oxy-Fuel Gas Welding Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to: A. Identify the major parts of the oxy-fuel gas unit. B. Pass
More informationUniversity of Tennessee Safety Guidelines
University of Tennessee Safety Guidelines Guideline Subject: Compressed Gases and Cryogenics Safety Guidelines Approval Date: 10/1/15 (Rev. 1) Next Scheduled Review: 10/1/19 Date Effective: 1/01/09 Contact
More informationType 119 Control Valve
Instruction Manual Form 5204 Type 119 December 2009 Type 119 Control Valve Introduction Scope of the Manual This instruction manual provides installation, spring adjustment, maintenance, and parts information
More informationWHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
More informationUser s Guide CARBON DIOXIDE CYLINDERS AND REGULATORS
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-6234 Telephone (800) 238-3600 Facsimile (612) 422-3246 User s Guide CARBON DIOXIDE CYLINDERS AND REGULATORS Part No. 316704000 June, 1974 Revised:
More informationNotes. Material 1. Appropriate Flammable Liquids
29 CFR 1910.106 Flammable Materials Flammable Liquids Preparation 1. Read Applicable Background information and related Company Policy Chapter. 2. Make Copies of this Lesson Plan for Personnel 3. Make
More informationNitrogen Blanketing for Methanol Storage and Transportation
Nitrogen Blanketing for Methanol Storage and Transportation Overview Air is the enemy of many materials. Not only can oxygen cause safety concerns and product degradation, but moisture, dirt, hydrocarbons
More informationA practical guide to restrictive flow orifices
Safetygram 46 A practical guide to restrictive flow orifices Restrictive flow orifices (RFOs) installed in cylinder valve outlets provide a significant safety benefit for users of hazardous gases, especially
More informationWhat to Expect From the Examination. How to Study the Plumbing Codes
Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.
More informationHydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
More informationAIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
More informationKNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
More informationIndex 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
More information289 Series Spring-Loaded Relief Valves
October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The
More informationIn This Section. In This Section Safety Containers & Cabinets. Choosing a Safety Cabinet. Choosing a Safety Can
In This Section Safety ontainers & abinets hoosing a Safety abinet We ve made choosing Safety abinets and ans easy. Simply look over the categories below and choose the best option for your workplace.
More informationIllinois Manufacturers Best Practices January 2016 Webinar
Illinois Manufacturers Best Practices January 2016 Webinar Combustible Dust Housekeeping: Stay Safe & Compliant January 28, 2016 Combustible Dust Housekeeping: Stay Safe & Compliant Andrew Luessenhop,
More informationSMALL GAS OPERATOR OPERATION AND MAINTENANCE PLAN
SMALL GAS OPERATOR OPERATION AND MAINTENANCE PLAN Facility Name: Address: QUALIFIED PERSONNEL All tasks shall be completed by a person that is qualified to that task (see operators qualification of individuals
More information240-3118 AIR CUT OFF KIT INSTALLATION INSTRUCTIONS
OPERATION MANUAL GLOBAL ELECTRONIC MIX SOLUTIONS PLURAL COMPONT MIXING SYSTEM 240-3118 AIR CUT OFF KIT INSTALLATION INSTRUCTIONS 77-3087-R1.0 (8/2015) 1 / 5 In this part sheet, the words WARNING, CAUTION
More informationPIPE SUPPORT & ALIGNMENT SYSTEM CATALOG
PIPE SUPPORT & ALIGNMENT SYSTEM CATALOG Catalog 611 The Fastest and Most Economical Method to Postion and Support Plumbing Chase Piping. The Sumner Pipe Support System is designed to eliminate the problems
More informationInstallation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
More informationFACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
More informationFLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes
FLAMMABLE AND COMBUSTIBLE LIQUIDS OSHA Changes Introduction This module covers the two primary hazards associated with flammable and combustible liquids: explosion and fire. In order to prevent these hazards,
More informationTHE INSTRUCTIONS PRESENTED HERE ARE ORIENTED TO USERS OF CNG CYLINDERS AS WELL AS TO TECHNICIANS IN CHARGE OF THEIR INSTALLATION
FOREWORD THE INSTRUCTIONS PRESENTED HERE ARE ORIENTED TO USERS OF CNG CYLINDERS AS WELL AS TO TECHNICIANS IN CHARGE OF THEIR INSTALLATION CAUTION! READ THIS BEFORE This guide only has the objective of
More informationStatic Spark Ignites Flammable Liquid during Portable Tank Filling Operation
Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation No. 2008-02-I-IA (September 2008) Key Lessons for Safe Handling and Storage of Flammables Ensure that equipment, such as fill
More informationBPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap
1263050/6 IM-P126-07 ST Issue 6 BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation
More informationADMINISTRATIVE SERVICES MANUAL
Purpose Responsibilities Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and injuries. To minimize risk to life and properly, the requirements of
More informationPBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
More informationUCLA - Compressed Gas Cylinder Storage and Handling
UCLA - Compressed Gas Cylinder Storage and Handling Purpose UCLA is committed to provide safety guidelines concerning the handling and use of portable compressed gas cylinders. Compressed gases represent
More informationCombustible Dust Ensuring Safety and Compliance. Brian Edwards, PE Conversion Technology Inc. ENVIRONMENTAL & SAFETY CONSULTING ENGINEERS
Combustible Dust Ensuring Safety and Compliance Prepared for: REGION IV VPPPA Presented by: Brian Edwards, PE Conversion Technology Inc. ENVIRONMENTAL & SAFETY CONSULTING ENGINEERS 1 Scope of Discussion
More informationGraymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions
795 08690 GM 12 00 Graymills Air Operated Double Diaphragm Pumps Operations and Maintenance Instructions /S Read all these SAFETY INSTRUCTIONS BEFORE installing or using this equipment. Keep this manual
More informationIn accordance with NFPA 30, these containers are not to store Class I flammable liquids.
In accordance with NFPA 30, these containers are not to store Class I flammable liquids. Zurich recommends storing these containers in dedicated liquid storage rooms, detached buildings, or in listed dispensing
More informationProduct Safety Data Sheet (PSDS)
Product Safety Data Sheet (PSDS) SECTION 1: IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Product Name: DURACELL LITHIUM MANGANESE DIOXIDE COIN CELLS Representative Product
More informationOREGON FIRE CODE Interpretations and Technical Advisories
OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application
More informationMANI-FLEX AutoSwitch
ADI 3059-B Certified ISO 9000 MANI-FLEX AutoSwitch Automatic and Semi-Automatic Switchover Systems INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions
More informationPRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller
BLZPTS-1 NOVEMBER 19, 2013 TS350 TS752 BLPS PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller DESCRIPTION The BLPS, TS350
More informationGuidance for Those Who Use and Store Gas Cylinders
King s Gate Tel 6320 www.safety.ncl.ac.uk Safety Office February 2012 Guidance for Those Who Use and Store Gas Cylinders Version 3 Newcastle University 2012 This guide is designed to help staff manage
More informationMicro GC Fusion Pre-Installation Checklist
Site Preparation Proper site preparation prior to installing is very important. Contact INFICON (www.inficon.com) with any questions regarding site preparation. NOTE: Checkboxes ( ) identify hardware that
More information580-6001 INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES
ADI 3205-A Certified ISO 9001 580-6001 Micron Filter Assembly INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES Before Installing or Operating, Read and Comply with These
More informationOWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
More informationNewloc Acetal. Plastic Push-to-Connect Fittings. Fluid Transfer Specialists
Newloc Acetal Plastic Push-to-Connect Fittings Fluid Transfer Specialists Newloc Acetal Extremely easy to install no tools necessary Certified by the National Sanitation Foundation (NSF-1 and NSF-1) Instant
More informationfor ALL your Rupture Disk needs...
for ALL your Rupture Disk needs... Holders s Burst Sensors Alarm Monitoring Systems Transportation Disks Sanitary Disks Explosion Vent Panels Extruder Barrels Special Applications Service Personnel are
More informationSELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
More informationPlumbing Code in Commercial Kitchens
Plumbing Code in Commercial Kitchens City of Concord Code Administration 225-8580 Dan Clark Plumbing Inspector Tedd Evans, Chief Building Inspector Code References from the 2009 edition of the International
More informationMODEL J SERIES CONVERTER
3030 S Susan Street, MODEL J SERIES CONVERTER REPAIR KIT INSTRUCTIONS Important: Any maintenance, service or repair should be performed by trained and experienced service technicians. Proper tools and
More informationBURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
More informationSelect the Right Relief Valve - Part 1 Saeid Rahimi
Select the Right Relief Valve - Part 1 Saeid Rahimi 8-Apr-01 Introduction Selecting a proper type of relief valve is an essential part of an overpressure protection system design. The selection process
More informationStandard Operating Procedure: Flammable Liquids
Standard Operating Procedure: Flammable Liquids Standard operating procedures (SOP) are intended to provide you with general guidance on how to safely work with a specific class of chemical or hazard.
More informationPRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
More informationNewson Gale. Is it ever Safe to use Plastic Drums and Containers in Hazardous areas? White Paper. Author Details:
White Paper Is it ever Safe to use Plastic Drums Author Details: Mike O Brien, Head of Product Marketing for If you have any questions relating to the topics discussed in this article, you can contact
More informationSERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR 032-044-000 032-045-000 WARNING 12-32 VDC
SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR 032-044-000 032-045-000 } 12-32 VDC Specifications 032-044-000 and 032-045-000 WARNING Hazardous voltage. This Leak Detector is an electrical device.
More informationVe-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:
Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees
More informationFluid Regulator. Instructions Parts List 306563L LOW PRESSURE
Instructions Parts List LOW PRESSURE Fluid Regulator 306563L For accurate, positive control of fluid pressure to one spray gun, dispensing valve, or atomizing head. For professional use only. 250 psi (18
More informationASME B31.3 Process Piping. Scope of B31.3 Course
ASME B31.3 Process Piping Charles Becht IV, PhD, PE Don Frikken, PE Instructors BECHT ENGINEERING COMPANY, INC. Introduction -1 Scope of B31.3 Course This course covers piping as typically used in process
More informationOP300S / OP350 2:1 RATIO TRANSFER PUMP
OP300S / OP350 2:1 RATIO TRANSFER PUMP OPERATING MANUAL WITH PARTS IDENTIFICATION Copyright 2013 International Pump Manufacturing, Inc. This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Read and
More informationKOBOLD VKP FLOWMETER/SWITCH. User Instructions
KOBOLD VKP FLOWMETER/SWITCH User Instructions USA 1801 Parkway View Drive Pittsburgh, PA 15205 PH 412-788-2830 Canada 9A Aviation Point Claire, QC H9R 4Z2 PH 514-428-8090 www.koboldusa.com Manual_VKP_11-2014
More informationLIQUEFIED PETROLEUM GASES
CHAPTER 38 LIQUEFIED PETROLEUM GASES SECTION 3801 GENERAL 3801.1 Scope. Storage, handling and transportation of liquefied petroleum gas (LP-gas) and the installation of LP-gas equipment pertinent to systems
More informationDC400 Dispensing Cutoff System
DC400 Dispensing Cutoff System DC404 and DC406 Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com
More informationMaryland Containment System Testing Protocol. The individual performing the inspection and testing as outlined in this protocol must be either:
MARYLAND DEPARTMENT OF THE ENVIRONMENT Oil Control Program, Suite 620, 1800 Washington Blvd., Baltimore MD 21230-1719 4 410-537-3442 410-537-3092 (fax) 1-800-633-6101 http://www.mde.state.md.us Maryland
More informationAmerican Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems
American Fireglass Outdoor Fire pit kit information General instructions/warnings for outdoor gas pan and burner systems We strongly recommend that our burner products be installed by a licensed and certified
More informationScott Batcheller Manager Research & Development. Milwaukee, WI
Transferring Air-Sensitive Reagents Scott Batcheller Manager Research & Development Aldrich Chemistry Milwaukee, WI Background August 3, 2009, Vol. 87, Issue 3 Users of these materials should be technically
More informationDip Tanks. RS 1030 (9/13) 2013 Nationwide Mutual Insurance Company Page 1 of 9 All Rights Reserved
This Data Sheet discusses the fire and explosion hazards associated with dip tanks as well as several fire prevention tactics. EPA information is included as an added benefit only. The information from
More informationNational- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
More informationExceptional Accuracy and Durability for Tough Industrial Environments INDUSTRIAL FLOOR SCALES. VERTEX Industrial Floor Scales Heavy-Duty Design
VERTEX Industrial Floor Scales Heavy-Duty Design LOCATE HI-RES Exceptional Accuracy and Durability for Tough Industrial Environments INDUSTRIAL FLOOR SCALES METTLER TOLEDO VERTEX Floor Scales Heavy-Duty
More informationSection 14. Forklift Safety Contents 14.1 Operator Safety
Section 14. Forklift Safety Contents 14.1 Operator Safety... 14-1 14.2 Inspection and Maintenance... 14-2 14.3 Handling the Load... 14-3 14.4 Fueling Liquefied Petroleum (LP) Gas Forklifts... 14-3 14.5
More informationALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
More informationInstallation, Maintenance, & Repair Series 4000B/LF4000B
Installation, Maintenance, & Repair Series 4000B/LF4000B Reduced Pressure Zone Assemblies Sizes: 1 2" 2" (15 50mm) RP/IS-A-4000B 4000B/LF4000B Size: 3 /4"! WARNING Testing Read this Manual BEFORE using
More informationFACILITY SAFETY SIGNAGE GUIDE: 10 SIGNS TO SPOT DURING A PLANT WALKTHROUGH
FACILITY SAFETY SIGNAGE GUIDE: 10 SIGNS TO SPOT DURING A PLANT WALKTHROUGH Safety signs are the primary way to communicate important warnings and messages to your employees, on-site contractors and other
More informationPROCEDURES PREVENTION OF ACCIDENTAL IGNITION
Page No: 1 of 7 6.0 PURPOSE (192.751) All possible precautions shall be exercised to prevent the accidental escape and ignition of gas. Whenever possible, potential sources of ignition should be eliminated
More informationCOMPRESSED GAS SAFETY
COMPRESSED GAS SAFETY COMPRESSED GAS SAFETY I. Summary Compressed gas cylinders can present a variety of hazards due to their pressure and /or contents. All compressed gases used at UGA must be ordered
More informationSample Collection Procedures for Insulating Fluid Samples
Sample Collection Procedures for Insulating Fluid Samples GENERAL Sampling electrical insulating oil for laboratory analysis requires care to ensure that the sample is representative of the product being
More informationSubmersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
More informationSample Written Program. For. Flammable Liquids
Sample Written Program For Flammable Liquids 1 Flammable Liquids. (YOUR COMPANY NAME) Purpose Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and
More informationRGC-IR Remote Gas Calibrator for IR400
Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by
More informationWWW.IMEX-SOLUTIONS.NL
Safer technology for drum storage and dispensing. That is more than a Justrite commitment it s a reality. Justrite s drum faucets are safeguarded with an internal flame arrester and drum vents offer pressure
More informationCompressed Gas Cylinder Safety
ISC Compressed Gas Cylinder Safety Training page 1 Compressed Gas Cylinder Safety This training program is adapted from the online OSHA training program on the Oklahoma State University OSHA training web
More informationRecommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic
More information55-Gallon Dispenser Package
INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon ispenser Package 08666 Rev. C INSTRUCTIONS This manual contains important warnings and information. REA AN KEEP FOR REFERENCE. 100 psi (6.9 bar) Maximum Air
More informationMATERIAL SAFETY DATA SHEET - Air-Compressed
1. PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: CHEMICAL NAME: CHEMICAL FAMILY: SYNONYMS: CHEMICAL FORMULA: USE: NAME AND ADDRESS: Air, compressed Air Nonflammable gas Medical Air, Breathing Air, Compressed
More informationSPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY
SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY Construction Criteria The unit costs for (Wet) space types are based on the construction quality and design features in the following table. This
More informationInstallation Instructions for Contractors. Connection Sets. Solar Twin Tube. Inox 1/2" Inox 3/4" 6 720 646 309 (2011/02) US/CA
Installation Instructions for Contractors Connection Sets Solar Twin Tube Inox 1/2" Inox 3/4" 6 720 646 309 (2011/02) US/CA Contents Contents 1 Explanation of symbols and safety information 3 1.1 Explanation
More informationHazardous Waste Determination and Management Plan
Hazardous Waste Determination and Management Plan Prepared By: Triumvirate Environmental Developed: November 2014 Updated: Program Approval Associate Vice President of Public Safety & Administrative Services
More informationFDA STAFF MANUAL GUIDES, VOLUME I - ORGANIZATIONS AND FUNCTIONS FOOD AND DRUG ADMINISTRATION OFFICE OF GLOBAL AND REGULATORY OPERATIONS AND POLICY
SMG 1312.4 FDA STAFF MANUAL GUIDES, VOLUME I - ORGANIZATIONS AND FUNCTIONS FOOD AND DRUG ADMINISTRATION OFFICE OF GLOBAL AND REGULATORY OPERATIONS AND POLICY OFFICE OF REGULATORY AFFAIRS OFFICE OF OPERATIONS
More information