1 Red Hat Ceph Storage Hardware Guide Hardware recommendations for Red Hat Ceph Storage v Red Hat Customer Content Services
2
3 Red Hat Ceph Storage Hardware Guide Hardware recommendations for Red Hat Ceph Storage v1.2.3.
4 Legal Notice Copyright 2015 Red Hat, Inc. The text of and illustrations in this document are licensed by Red Hat under a Creative Commons Attribution Share Alike 3.0 Unported license ("CC-BY-SA"). An explanation of CC-BY-SA is available at In accordance with CC-BY-SA, if you distribute this document or an adaptation of it, you must provide the URL for the original version. Red Hat, as the licensor of this document, waives the right to enforce, and agrees not to assert, Section 4d of CC-BY-SA to the fullest extent permitted by applicable law. Red Hat, Red Hat Enterprise Linux, the Shadowman logo, JBoss, MetaMatrix, Fedora, the Infinity Logo, and RHCE are trademarks of Red Hat, Inc., registered in the United States and other countries. Linux is the registered trademark of Linus Torvalds in the United States and other countries. Java is a registered trademark of Oracle and/or its affiliates. XFS is a trademark of Silicon Graphics International Corp. or its subsidiaries in the United States and/or other countries. MySQL is a registered trademark of MySQL AB in the United States, the European Union and other countries. Node.js is an official trademark of Joyent. Red Hat Software Collections is not formally related to or endorsed by the official Joyent Node.js open source or commercial project. The OpenStack Word Mark and OpenStack Logo are either registered trademarks/service marks or trademarks/service marks of the OpenStack Foundation, in the United States and other countries and are used with the OpenStack Foundation's permission. We are not affiliated with, endorsed or sponsored by the OpenStack Foundation, or the OpenStack community. All other trademarks are the property of their respective owners. Abstract This document provides high level guidance on selecting hardware for use with Red Hat Ceph Storage.
5 Table of Contents Table of Contents. PREFACE PART..... I.. HOST RECOMMENDATIONS CHAPTER CPU CHAPTER RAM CHAPTER DATA..... STORAGE IDENTICAL CONFIGURATIONS JOURNALING HARD DISK DRIVES AVOID RAID SOLID STATE DRIVES CONTROLLERS ADDITIONAL CONSIDERATIONS 9. PART..... II... NETWORKING RECOMMENDATIONS CHAPTER GBPS CHAPTER USE.... A.. CLUSTER/BACKSIDE NETWORK CHAPTER MULTI-RACK CONSIDERATIONS CHAPTER MULTIPLE DATACENTERS CHAPTER IPV CHAPTER PORTS CHAPTER USE.... NTP CHAPTER IPMI PART..... III... MINIMUM HARDWARE RECOMMENDATIONS CHAPTER PRODUCTION CLUSTERS CALAMARI MONITORS OSDS 21 1
6 Red Hat Ceph Storage Hardware Guide 2
7 PREFACE PREFACE Ceph was designed to run on commodity hardware, which makes building and maintaining petabyteto-exabyte scale data clusters economically feasible. When planning out your cluster hardware, you will need to balance a number of considerations, including failure domains and potential performance issues. Hardware planning should include distributing Ceph daemons and other processes that use Ceph across many hosts. 3
8 Red Hat Ceph Storage Hardware Guide PART I. HOST RECOMMENDATIONS Generally, we recommend running Ceph daemons of a specific type on a host configured for that type of daemon. We recommend using other hosts for processes that utilize your data cluster (e.g., OpenStack, CloudStack, etc). How you select and configure a Ceph OSD host has a lot to do with how you intend to use the OSDs on it (e.g., for OpenStack volumes and images, for an S3 gateway, for a fast SSD pool or cache tier, etc.). See the Ceph s Storage Stragegies Guide for details about defining storage strategies for your Ceph use case(s) and use these recommendations to help define your host requirements. 4
9 CHAPTER 1. CPU CHAPTER 1. CPU Ceph OSDs run the storage cluster service, calculate data placement with CRUSH, replicate data, and maintain their own copy of the cluster map. Ceph OSDs that host erasure-coded pools will use more CPU than Ceph OSDs that host replicated pools. Therefore, OSDs should have a reasonable amount of processing power and should consider the storage strategy(ies) you intend to use. Monitors simply maintain a master copy of the cluster map, so they are not CPU intensive. You must also consider whether the host machine will run CPU-intensive processes in addition to Ceph daemons. For example, if your hosts will run computing VMs (e.g., OpenStack Nova), you will need to ensure that these other processes leave sufficient processing power for Ceph daemons. We recommend running additional CPU-intensive processes on separate hosts. 5
10 Red Hat Ceph Storage Hardware Guide CHAPTER 2. RAM Ceph monitors must be capable of serving their data quickly, so they should have plenty of RAM (e.g., 1GB of RAM per daemon instance). OSDs do not require as much RAM for regular operations (e.g., 500MB of RAM per daemon instance); however, during recovery they need significantly more RAM (e.g., ~1GB for 1TB of storage per daemon or more). Generally, more RAM is better (e.g., page caching). 6
11 CHAPTER 3. DATA STORAGE CHAPTER 3. DATA STORAGE Plan your data storage configuration carefully. There are significant cost and performance tradeoffs to consider when planning for data storage. Simultaneous OS operations and simultaneous requests for read and write operations from multiple daemons against a single drive can slow performance considerably. Ceph can operate with heterogeneous systems. CRUSH supports weighting for different sized drives (e.g., 1TB, 3TB, etc), and primary affinity (the likeliness an OSD would be used as a primary) to address the performance issues introduced by dissimilar hardware in the same pool. However, using homogeneous configurations for the OSDs assigned to a pool is recommended IDENTICAL CONFIGURATIONS We recommend creating pools and defining CRUSH hierarchies such that the OSD hardware within the pool is identical. That is: Same controller Same drive size Same RPMs Same seek times Same I/O Same network throughput Same journal configuration Using the same hardware within a pool provides a consistent performance profile, simplifies provisioning and streamlines troubleshooting JOURNALING There are also file system limitations to consider: btrfs is not quite stable enough for production, but it has the ability to journal and write data simultaneously, whereas XFS and ext4 do not. Important Since Ceph has to write all data to the journal before it can send an ACK (for XFS and EXT4 at least), having the journal and OSD performance in balance is really important! 3.3. HARD DISK DRIVES OSDs should have plenty of hard disk drive space for object data. We recommend a minimum hard disk drive size of 1 terabyte. Consider the cost-per-gigabyte advantage of larger disks. We recommend dividing the price of the hard disk drive by the number of gigabytes to arrive at a cost per gigabyte, because larger drives may have a significant impact on the cost-per-gigabyte. For example, a 1 terabyte hard disk priced at $75.00 has a cost of $0.07 per gigabyte (i.e., $75 / 1024 = ). By contrast, a 3 terabyte hard disk priced at $ has a cost of $0.05 per gigabyte (i.e., $150 / 3072 = ). In the foregoing example, using the 1 terabyte disks would generally 7
12 Red Hat Ceph Storage Hardware Guide increase the cost per gigabyte by 40%--rendering your cluster substantially less cost efficient. Also, the larger the storage drive capacity, the more memory per Ceph OSD Daemon you will need, especially during rebalancing, backfilling and recovery. A general rule of thumb is ~1GB of RAM for 1TB of storage space. Tip Running multiple OSDs on a single disk irrespective of partitions is NOT a good idea. Tip Running an OSD and a monitor on a single disk irrespective of partitions is NOT a good idea. Storage drives are subject to limitations on seek time, access time, read and write times, as well as total throughput. These physical limitations affect overall system performance especially during recovery. We recommend using a dedicated drive for the operating system and software, and one drive for each Ceph OSD Daemon you run on the host. Most "slow OSD" issues arise due to running an operating system, multiple OSDs, and/or multiple journals on the same drive. Since the cost of troubleshooting performance issues on a small cluster likely exceeds the cost of the extra disk drives, you can accelerate your cluster design planning by avoiding the temptation to overtax the OSD storage drives. You may run multiple Ceph OSD Daemons per hard disk drive, but this will likely lead to resource contention and diminish the overall throughput. You may store a journal and object data on the same drive, but this may increase the time it takes to journal a write and ACK to the client. Ceph must write to the journal before it can ACK the write. The btrfs filesystem can write journal data and object data simultaneously, whereas XFS and ext4 cannot. Ceph best practices dictate that you should run operating systems, OSD data and OSD journals on separate drives. SSDs for operating system drives are preferred AVOID RAID Ceph replicates or erasure codes objects. RAID is redundant and reduces available capacity, and therefore an unnecessary expense. A degraded RAID will have a negative impact on performance. If you have systems with RAID controllers, configure them for RAID 0 (JBOD) SOLID STATE DRIVES One opportunity for performance improvement is to use solid-state drives (SSDs) to reduce random access time and read latency while accelerating throughput. SSDs often cost more than 10x as much per gigabyte when compared to a hard disk drive, but SSDs often exhibit access times that are at least 100x faster than a hard disk drive. SSDs do not have moving mechanical parts so they aren t necessarily subject to the same types of limitations as hard disk drives. SSDs do have significant limitations though. When evaluating SSDs, it is important to consider the performance of sequential reads and writes. An SSD that has 400MB/s sequential write throughput may have much better performance than an SSD with 120MB/s of sequential write throughput when storing multiple journals for multiple OSDs. 8
13 CHAPTER 3. DATA STORAGE Important We recommend exploring the use of SSDs to improve performance. However, before making a significant investment in SSDs, we strongly recommend both reviewing the performance metrics of an SSD and testing the SSD in a test configuration to gauge performance. Since SSDs have no moving mechanical parts, it makes sense to use them in the areas of Ceph that do not use a lot of storage space (e.g., journals or cache-tiers). Relatively inexpensive SSDs may appeal to your sense of economy. Use caution. Acceptable IOPS are not enough when selecting an SSD for use with Ceph. There are a few important performance considerations for journals and SSDs: Write-intensive semantics: Journaling involves write-intensive semantics, so you should ensure that the SSD you choose to deploy will perform equal to or better than a hard disk drive when writing data. Inexpensive SSDs may introduce write latency even as they accelerate access time, because sometimes high performance hard drives can write as fast or faster than some of the more economical SSDs available on the market! Sequential Writes: When you store multiple journals on an SSD you must consider the sequential write limitations of the SSD too, since they may be handling requests to write to multiple OSD journals simultaneously. Partition Alignment: A common problem with SSD performance is that people like to partition drives as a best practice, but they often overlook proper partition alignment with SSDs, which can cause SSDs to transfer data much more slowly. Ensure that SSD partitions are properly aligned. While SSDs are cost prohibitive for object storage, OSDs may see a significant performance improvement by storing an OSD s journal on an SSD and the OSD s object data on a separate hard disk drive. The osd journal configuration setting defaults to /var/lib/ceph/osd/$cluster- $id/journal. You can mount this path to an SSD or to an SSD partition so that it is not merely a file on the same drive as the object data CONTROLLERS Disk controllers also have a significant impact on write throughput. Carefully, consider your selection of disk controllers to ensure that they do not create a performance bottleneck ADDITIONAL CONSIDERATIONS You may run multiple OSDs per host, but you should ensure that the sum of the total throughput of your OSD hard disks doesn t exceed the network bandwidth required to service a client s need to read or write data. You should also consider what percentage of the overall data the cluster stores on each host. If the percentage on a particular host is large and the host fails, it can lead to problems such as exceeding the full ratio, which causes Ceph to halt operations as a safety precaution that prevents data loss. 9
14 Red Hat Ceph Storage Hardware Guide PART II. NETWORKING RECOMMENDATIONS Carefully consider bandwidth requirements for your cluster network, be mindful of network link oversubscription, and segregate the intra-cluster traffic from the client-to-cluster traffic. 10
15 CHAPTER 4. 10GBPS CHAPTER 4. 10GBPS On smaller clusters, 1Gbps networks may be suitable for normal operating conditions, but not for heavy loads or failure recovery scenarios. In the case of a drive failure, replicating 1TB of data across a 1Gbps network takes 3 hours, and 3TBs (a typical drive configuration) takes 9 hours. By contrast, with a 10Gbps network, the replication times would be 20 minutes and 1 hour respectively. Remember that when an OSD fails, the cluster will recover by replicating the data it contained to other OSDs within the pool. failed OSD(s) total OSDs The failure of a larger domain such as a rack means that your cluster will utilize considerably more bandwidth. Administrators usually prefer that a cluster recovers as quickly as possible. At a minimum, a single 10Gbps Ethernet link should be used for storage hardware. If your Ceph nodes have many drives each, add additional 10Gbps Ethernet links for connectivity and throughput. 11
16 Red Hat Ceph Storage Hardware Guide CHAPTER 5. USE A CLUSTER/BACKSIDE NETWORK Ceph supports a public (front-side) network and a cluster (back-side) network. The public network handles client traffic and communication with Ceph monitors. The cluster (back-side) network handles OSD heartbeats, replication, backfilling and recovery traffic. We recommend allocating bandwidth to the cluster (back-side) network such that it is a multiple of the front-side network using osd pool default size as the basis for your multiple. We also recommend running the public and cluster networks on separate NICs. 12
17 CHAPTER 6. MULTI-RACK CONSIDERATIONS CHAPTER 6. MULTI-RACK CONSIDERATIONS If you are building a cluster consisting of multiple racks (common for large clusters), consider utilizing as much network bandwidth between switches in a "fat tree" design for optimal performance. A typical 10Gbps Ethernet switch has 48 10Gbps ports and four 40Gbps ports. If you only use one one 40Gbps port for connectivity, you can only connect 4 servers at full speed (i.e., 10gbps x 4). Use your 40Gbps ports for maximum throughput. If you have unused 10G ports, you can aggregate them (with QSFP+ to 4x SFP+ cables) into more 40G ports to connect to other racks and to spine routers. For network optimization, we recommend a jumbo frame for a better CPU/bandwidth ratio. We also recommend a non-blocking network switch back-plane. 13
18 Red Hat Ceph Storage Hardware Guide CHAPTER 7. MULTIPLE DATACENTERS You may deploy a Ceph cluster across geographic regions; however, this is NOT RECOMMENDED UNLESS you use a dedicated network connection between datacenters. Ceph prefers consistency and acknowledges writes synchronously. Using the internet (packet-switched with many hops) between geographically separate datacenters will introduce significant write latency. You may specify multiple IP addresses and subnets for your public and cluster networks in your Ceph configuration file. For example: public network {ip-address}/{netmask} [, {ip-address}/{netmask}] cluster network {ip-address}/{netmask} [, {ip-address}/{netmask}] Ensure that the IP addresses/subnets within the public network can reach each other, and the IP addresses/subnets within the cluster network can reach each other. We recommend keeping the cluster network separate from the public network and not connected to the internet to prevent DDOS attacks from crippling heartbeats, replication, backfilling and recovery. 14
19 CHAPTER 8. IPV6 CHAPTER 8. IPV6 You may use IPv6 addresses; however, you must enable daemons to bind to them first. For example, you may enable IPv6 in your Ceph configuration file: ms bind ipv6 = true 15
20 Red Hat Ceph Storage Hardware Guide CHAPTER 9. PORTS Monitors use port 6789 by default. Ensure you have the port open for each monitor host. Each Ceph OSD Daemon on a Ceph Node may use up to three ports, beginning at port 6800: 1. One for talking to clients and monitors. 2. One for sending data to other OSDs (replication, backfill and recovery). 3. One for heartbeating. You need to open at least three ports per OSD beginning at port 6800 on a Ceph node to ensure that the OSDs can peer. The port for talking to monitors and clients must be open on the public (frontside) network. The ports for sending data to other OSDs and heartbeating must be open on the cluster (back-side) network. If you want to use a different port range than 6800:7100 for Ceph daemons, you must adjust the following settings in your Ceph configuration file: ms bind port min = {min-port-num} ms bind port max = {max-port-num} Ceph monitors bind on port 6789 by default. If you want to use a different port number than 6789, you may specify the the IP address and port in your Ceph configuration. For example: [mon.monname] host = {hostname} mon addr = {ip-address}:{port} 16
21 CHAPTER 10. USE NTP CHAPTER 10. USE NTP We further recommend installing NTP on your Ceph nodes especially Ceph monitor nodes. Without clock synchronization, clock drift may prevent monitors from agreeing on the state of the cluster, which means that clients lose access to data until the quorum is re-established and the monitors agree on the state of the cluster. 17
22 Red Hat Ceph Storage Hardware Guide CHAPTER 11. IPMI As a best practice, we also recommend a 1GbE copper interface for an IPMI network. 18
23 PART III. MINIMUM HARDWARE RECOMMENDATIONS PART III. MINIMUM HARDWARE RECOMMENDATIONS Ceph can run on commodity hardware. Small production clusters and development clusters can run successfully with modest hardware. Process Criteria Minimum Recommended calamari Processor 1x 64-bit x86-64 quad-core RAM 4 GB minimum per instance Disk Space 10 GB per instance Network 2x 1GB Ethernet NICs ceph-osd Processor 1x 64-bit x86-64 RAM ~1GB for 1TB of storage per daemon Volume Storage 1x storage drive per daemon Journal 1x SSD partition per daemon (optional) Network 2x 1GB Ethernet NICs ceph-mon Processor 1x 64-bit x86-64 RAM 1 GB per daemon Disk Space 10 GB per daemon Network 2x 1GB Ethernet NICs 19
24 Red Hat Ceph Storage Hardware Guide Tip If you are running an OSD with a single disk, create a partition for your volume storage that is separate from the partition containing the OS. Generally, we recommend separate disks for the OS and the volume storage. 20
25 CHAPTER 12. PRODUCTION CLUSTERS CHAPTER 12. PRODUCTION CLUSTERS Production clusters for petabyte scale data storage may also use commodity hardware, but should have considerably more memory, processing power and data storage to account for heavy traffic loads CALAMARI The administration server hardware requirements vary with the size of your cluster. A minimum recommended hardware configuration for a Calamari server includes at least 4GB of RAM, a dual core CPU on x86_64 architecture and enough network throughput to handle communication with Ceph hosts. The hardware requirements scale linearly with the number of Ceph servers, so if you intend to run a fairly large cluster, ensure that you have enough RAM, processing power and network throughput for your administration node MONITORS While it is tempting to run monitors on a single node, you SHOULD NOT do this in production. Monitors are relatively lightweight, but their purpose is to ensure high availability. Monitors are also fsync intensive. Consider using a high performance SSD for monitor data. You SHOULD NOT commingle monitor daemons and OSD daemons in production systems. It is also a good idea to ensure that monitors have back-up power. In the event that monitor power fails, and the monitor cluster cannot achieve a quorum, you will lose access to data until the monitors are back up and achieve a quorum. Remember, monitors are light weight, but they are mission critical to ensure high availability OSDS Ensure that your network interface, controllers and drive throughput don t leave bottlenecks e.g., fast drives, but networks too slow to accommodate them. SSDs are typically used for journals and fast pools. Where the use of SSDs is write intensive (e.g., journals), make sure you select high performance SSDs. When using Ceph as a backend for OpenStack volumes and images, we recommend a host bus adapter with SAS drives (10-15k rpms) and enterprise-grade SSDs using the same controller for journals. 21
Deploying Ceph with High Performance Networks, Architectures and benchmarks for Block Storage Solutions
WHITE PAPER May 2014 Deploying Ceph with High Performance Networks, Architectures and benchmarks for Block Storage Solutions Contents Executive Summary...2 Background...2 Network Configuration...3 Test
Red Hat JBoss Core Services Apache HTTP Server 2.4 Apache HTTP Server Installation Guide
Red Hat JBoss Core Services Apache HTTP Server 2.4 Apache HTTP Server Installation Guide For use with Red Hat JBoss middleware products. Red Hat Customer Content Services Red Hat JBoss Core Services Apache
Red Hat Enterprise Linux OpenStack Platform 7 OpenStack Data Processing
Red Hat Enterprise Linux OpenStack Platform 7 OpenStack Data Processing Manually provisioning and scaling Hadoop clusters in Red Hat OpenStack OpenStack Documentation Team Red Hat Enterprise Linux OpenStack
Red Hat Enterprise Linux OpenStack Platform 7 Back Up and Restore Red Hat Enterprise Linux OpenStack Platform
Red Hat Enterprise Linux OpenStack Platform 7 Back Up and Restore Red Hat Enterprise Linux OpenStack Platform Backup and Restore the Director undercloud OpenStack Team Red Hat Enterprise Linux OpenStack
Parallels Cloud Storage
Parallels Cloud Storage White Paper Best Practices for Configuring a Parallels Cloud Storage Cluster www.parallels.com Table of Contents Introduction... 3 How Parallels Cloud Storage Works... 3 Deploying
Red Hat Subscription Management All Subscription Docs Quick Registration for RHEL
Red Hat Subscription Management All Subscription Docs Quick Registration for RHEL quickly register and subscribe Red Hat Enterprise Linux systems Edition 4 John Ha Deon Ballard Red Hat Subscription Management
Red Hat Enterprise linux 5 Continuous Availability
Red Hat Enterprise linux 5 Continuous Availability Businesses continuity needs to be at the heart of any enterprise IT deployment. Even a modest disruption in service is costly in terms of lost revenue
PARALLELS CLOUD STORAGE
PARALLELS CLOUD STORAGE Performance Benchmark Results 1 Table of Contents Executive Summary... Error! Bookmark not defined. Architecture Overview... 3 Key Features... 5 No Special Hardware Requirements...
Deployment Guide. How to prepare your environment for an OnApp Cloud deployment.
Deployment Guide How to prepare your environment for an OnApp Cloud deployment. Document version 1.07 Document release date 28 th November 2011 document revisions 1 Contents 1. Overview... 3 2. Network
Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array
Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array Evaluation report prepared under contract with Lenovo Executive Summary Even with the price of flash
Agenda. Enterprise Application Performance Factors. Current form of Enterprise Applications. Factors to Application Performance.
Agenda Enterprise Performance Factors Overall Enterprise Performance Factors Best Practice for generic Enterprise Best Practice for 3-tiers Enterprise Hardware Load Balancer Basic Unix Tuning Performance
ZCP 7.0 (build 41322) Zarafa Collaboration Platform. Zarafa Archiver Deployment Guide
ZCP 7.0 (build 41322) Zarafa Collaboration Platform Zarafa Archiver Deployment Guide Zarafa Collaboration Platform ZCP 7.0 (build 41322) Zarafa Collaboration Platform Zarafa Archiver Deployment Guide Edition
3 Red Hat Enterprise Linux 6 Consolidation
Whitepaper Consolidation EXECUTIVE SUMMARY At this time of massive and disruptive technological changes where applications must be nimbly deployed on physical, virtual, and cloud infrastructure, Red Hat
Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays
Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays Database Solutions Engineering By Murali Krishnan.K Dell Product Group October 2009
Flying Circus RCA report #13271 2014-03-17. FOCAL POINT! Reduced storage performance causing outages in customer applications!
Christian Theune Root Cause Analysis FOCAL POINT Reduced storage performance causing outages in customer applications WHEN from Tuesday, 2014-03-04 16:16 until Thursday, 2014-03-06 17:50 while replacing
Cloud Storage. Parallels. Performance Benchmark Results. White Paper. www.parallels.com
Parallels Cloud Storage White Paper Performance Benchmark Results www.parallels.com Table of Contents Executive Summary... 3 Architecture Overview... 3 Key Features... 4 No Special Hardware Requirements...
SAN Conceptual and Design Basics
TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer
Solving I/O Bottlenecks to Enable Superior Cloud Efficiency
WHITE PAPER Solving I/O Bottlenecks to Enable Superior Cloud Efficiency Overview...1 Mellanox I/O Virtualization Features and Benefits...2 Summary...6 Overview We already have 8 or even 16 cores on one
Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays. Red Hat Performance Engineering
Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays Red Hat Performance Engineering Version 1.0 August 2013 1801 Varsity Drive Raleigh NC
VIDEO SURVEILLANCE WITH SURVEILLUS VMS AND EMC ISILON STORAGE ARRAYS
VIDEO SURVEILLANCE WITH SURVEILLUS VMS AND EMC ISILON STORAGE ARRAYS Successfully configure all solution components Use VMS at the required bandwidth for NAS storage Meet the bandwidth demands of a 2,200
Red Hat Enterprise Linux 7 High Availability Add-On Administration. Configuring and Managing the High Availability Add-On
Red Hat Enterprise Linux 7 High Availability Add-On Administration Configuring and Managing the High Availability Add-On Red Hat Enterprise Linux 7 High Availability Add-On Administration Configuring
JBoss Developer Studio 6.0
JBoss Developer Studio 6.0 OpenShift Tools Reference Guide 1 JBoss Developer Studio 6.0 OpenShift Tools Reference Guide Provides information about the use of the JBoss Developer Studio with the Red Hat
Quantum StorNext. Product Brief: Distributed LAN Client
Quantum StorNext Product Brief: Distributed LAN Client NOTICE This product brief may contain proprietary information protected by copyright. Information in this product brief is subject to change without
VDI Appliances Accelerate and Simplify Virtual Desktop Deployment
VDI Appliances Accelerate and Simplify Virtual Desktop Deployment Introduction Early desktop virtualization adopters quickly learned that success or failure of a VDI implementation very often hinged on
All-Flash Arrays Weren t Built for Dynamic Environments. Here s Why... This whitepaper is based on content originally posted at www.frankdenneman.
WHITE PAPER All-Flash Arrays Weren t Built for Dynamic Environments. Here s Why... This whitepaper is based on content originally posted at www.frankdenneman.nl 1 Monolithic shared storage architectures
Dell Virtual Remote Desktop Reference Architecture. Technical White Paper Version 1.0
Dell Virtual Remote Desktop Reference Architecture Technical White Paper Version 1.0 July 2010 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES.
Symantec Endpoint Protection 11.0 Architecture, Sizing, and Performance Recommendations
Symantec Endpoint Protection 11.0 Architecture, Sizing, and Performance Recommendations Technical Product Management Team Endpoint Security Copyright 2007 All Rights Reserved Revision 6 Introduction This
A virtual SAN for distributed multi-site environments
Data sheet A virtual SAN for distributed multi-site environments What is StorMagic SvSAN? StorMagic SvSAN is a software storage solution that enables enterprises to eliminate downtime of business critical
Moving Virtual Storage to the Cloud
Moving Virtual Storage to the Cloud White Paper Guidelines for Hosters Who Want to Enhance Their Cloud Offerings with Cloud Storage www.parallels.com Table of Contents Overview... 3 Understanding the Storage
Deep Dive on SimpliVity s OmniStack A Technical Whitepaper
Deep Dive on SimpliVity s OmniStack A Technical Whitepaper By Hans De Leenheer and Stephen Foskett August 2013 1 Introduction This paper is an in-depth look at OmniStack, the technology that powers SimpliVity
Nutanix Tech Note. Configuration Best Practices for Nutanix Storage with VMware vsphere
Nutanix Tech Note Configuration Best Practices for Nutanix Storage with VMware vsphere Nutanix Virtual Computing Platform is engineered from the ground up to provide enterprise-grade availability for critical
Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study
White Paper Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study 2012 Cisco and/or its affiliates. All rights reserved. This
MaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products
MaxDeploy Ready Hyper- Converged Virtualization Solution With SanDisk Fusion iomemory products MaxDeploy Ready products are configured and tested for support with Maxta software- defined storage and with
On- Prem MongoDB- as- a- Service Powered by the CumuLogic DBaaS Platform
On- Prem MongoDB- as- a- Service Powered by the CumuLogic DBaaS Platform Page 1 of 16 Table of Contents Table of Contents... 2 Introduction... 3 NoSQL Databases... 3 CumuLogic NoSQL Database Service...
PARALLELS SERVER BARE METAL 5.0 README
PARALLELS SERVER BARE METAL 5.0 README 1999-2011 Parallels Holdings, Ltd. and its affiliates. All rights reserved. This document provides the first-priority information on the Parallels Server Bare Metal
Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices
Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices A Dell Technical White Paper Dell Symantec THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND
Pivot3 Reference Architecture for VMware View Version 1.03
Pivot3 Reference Architecture for VMware View Version 1.03 January 2012 Table of Contents Test and Document History... 2 Test Goals... 3 Reference Architecture Design... 4 Design Overview... 4 The Pivot3
Red Hat CloudForms 3.2 NetApp Storage Integration Guide
Red Hat CloudForms 3.2 NetApp Storage Integration Guide Technology preview feature that enables you to collect NetApp Storage data using CloudForms Management Engine Red Hat CloudForms Documentation Team
OPTIMIZING SERVER VIRTUALIZATION
OPTIMIZING SERVER VIRTUALIZATION HP MULTI-PORT SERVER ADAPTERS BASED ON INTEL ETHERNET TECHNOLOGY As enterprise-class server infrastructures adopt virtualization to improve total cost of ownership (TCO)
An Oracle White Paper December 2011. Oracle Virtual Desktop Infrastructure: A Design Proposal for Hosted Virtual Desktops
An Oracle White Paper December 2011 Oracle Virtual Desktop Infrastructure: A Design Proposal for Hosted Virtual Desktops Introduction... 2! Design Goals... 3! Architectural Overview... 5! Logical Architecture...
Red Hat Cloud Infrastructure 5 Release Notes
Red Hat Cloud Infrastructure 5 Release Notes Release Notes for Red Hat Cloud Infrastructure 5.0 Red Hat Cloud Infrastructure Documentation Team Red Hat Cloud Infrastructure 5 Release Notes Release Notes
Qsan Document - White Paper. Performance Monitor Case Studies
Qsan Document - White Paper Performance Monitor Case Studies Version 1.0 November 2014 Copyright Copyright@2004~2014, Qsan Technology, Inc. All rights reserved. No part of this document may be reproduced
Microsoft Private Cloud Fast Track Reference Architecture
Microsoft Private Cloud Fast Track Reference Architecture Microsoft Private Cloud Fast Track is a reference architecture designed to help build private clouds by combining Microsoft software with NEC s
Windows Server Performance Monitoring
Spot server problems before they are noticed The system s really slow today! How often have you heard that? Finding the solution isn t so easy. The obvious questions to ask are why is it running slowly
InterWorx Clustering Guide. by InterWorx LLC
InterWorx Clustering Guide by InterWorx LLC Contents 1 What Is Clustering? 3 1.1 What Does Clustering Do? What Doesn t It Do?............................ 3 1.2 Why Cluster?...............................................
Parallels Cloud Server 6.0
Parallels Cloud Server 6.0 Parallels Cloud Storage I/O Benchmarking Guide September 05, 2014 Copyright 1999-2014 Parallels IP Holdings GmbH and its affiliates. All rights reserved. Parallels IP Holdings
Traditional v/s CONVRGD
Traditional v/s CONVRGD Traditional Virtualization Stack Converged Virtualization Infrastructure with HCE/HSE Data protection software applications PDU Backup Servers + Virtualization Storage Switch HA
Preparation Guide. How to prepare your environment for an OnApp Cloud v3.0 (beta) deployment.
Preparation Guide v3.0 BETA How to prepare your environment for an OnApp Cloud v3.0 (beta) deployment. Document version 1.0 Document release date 25 th September 2012 document revisions 1 Contents 1. Overview...
Reference Design: Scalable Object Storage with Seagate Kinetic, Supermicro, and SwiftStack
Reference Design: Scalable Object Storage with Seagate Kinetic, Supermicro, and SwiftStack May 2015 Copyright 2015 SwiftStack, Inc. swiftstack.com Page 1 of 19 Table of Contents INTRODUCTION... 3 OpenStack
Oracle Database Scalability in VMware ESX VMware ESX 3.5
Performance Study Oracle Database Scalability in VMware ESX VMware ESX 3.5 Database applications running on individual physical servers represent a large consolidation opportunity. However enterprises
IOmark- VDI. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC- 150427- b Test Report Date: 27, April 2015. www.iomark.
IOmark- VDI HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC- 150427- b Test Copyright 2010-2014 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VM, VDI- IOmark, and IOmark
Cloud Server. Parallels. Key Features and Benefits. White Paper. www.parallels.com
Parallels Cloud Server White Paper Key Features and Benefits www.parallels.com Table of Contents Introduction... 3 Key Features... 3 Distributed Cloud Storage (Containers and Hypervisors)... 3 Rebootless
Apache Hadoop Cluster Configuration Guide
Community Driven Apache Hadoop Apache Hadoop Cluster Configuration Guide April 2013 2013 Hortonworks Inc. http://www.hortonworks.com Introduction Sizing a Hadoop cluster is important, as the right resources
The functionality and advantages of a high-availability file server system
The functionality and advantages of a high-availability file server system This paper discusses the benefits of deploying a JMR SHARE High-Availability File Server System. Hardware and performance considerations
Recommended hardware system configurations for ANSYS users
Recommended hardware system configurations for ANSYS users The purpose of this document is to recommend system configurations that will deliver high performance for ANSYS users across the entire range
Brocade Solution for EMC VSPEX Server Virtualization
Reference Architecture Brocade Solution Blueprint Brocade Solution for EMC VSPEX Server Virtualization Microsoft Hyper-V for 50 & 100 Virtual Machines Enabled by Microsoft Hyper-V, Brocade ICX series switch,
Achieving Real-Time Business Solutions Using Graph Database Technology and High Performance Networks
WHITE PAPER July 2014 Achieving Real-Time Business Solutions Using Graph Database Technology and High Performance Networks Contents Executive Summary...2 Background...3 InfiniteGraph...3 High Performance
SLIDE 1 www.bitmicro.com. Previous Next Exit
SLIDE 1 MAXio All Flash Storage Array Popular Applications MAXio N1A6 SLIDE 2 MAXio All Flash Storage Array Use Cases High speed centralized storage for IO intensive applications email, OLTP, databases
EMC Virtual Infrastructure for Microsoft Applications Data Center Solution
EMC Virtual Infrastructure for Microsoft Applications Data Center Solution Enabled by EMC Symmetrix V-Max and Reference Architecture EMC Global Solutions Copyright and Trademark Information Copyright 2009
W H I T E P A P E R : T E C H N I C A L. Understanding and Configuring Symantec Endpoint Protection Group Update Providers
W H I T E P A P E R : T E C H N I C A L Understanding and Configuring Symantec Endpoint Protection Group Update Providers Martial Richard, Technical Field Enablement Manager Table of Contents Content Introduction...
Red Hat OpenStack Platform 8 DNS-as-a-Service Guide
Red Hat OpenStack Platform 8 DNS-as-a-Service Guide Integrate DNS Management with Red Hat OpenStack Platform OpenStack Team Red Hat OpenStack Platform 8 DNS-as-a-Service Guide Integrate DNS Management
An Oracle White Paper July 2011. Oracle Primavera Contract Management, Business Intelligence Publisher Edition-Sizing Guide
Oracle Primavera Contract Management, Business Intelligence Publisher Edition-Sizing Guide An Oracle White Paper July 2011 1 Disclaimer The following is intended to outline our general product direction.
Cloud.com CloudStack Community Edition 2.1 Beta Installation Guide
Cloud.com CloudStack Community Edition 2.1 Beta Installation Guide July 2010 1 Specifications are subject to change without notice. The Cloud.com logo, Cloud.com, Hypervisor Attached Storage, HAS, Hypervisor
EMC Unified Storage for Microsoft SQL Server 2008
EMC Unified Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON and EMC FAST Cache Reference Copyright 2010 EMC Corporation. All rights reserved. Published October, 2010 EMC believes the information
DELL TM PowerEdge TM T610 500 Mailbox Resiliency Exchange 2010 Storage Solution
DELL TM PowerEdge TM T610 500 Mailbox Resiliency Exchange 2010 Storage Solution Tested with: ESRP Storage Version 3.0 Tested Date: Content DELL TM PowerEdge TM T610... 1 500 Mailbox Resiliency
DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION
DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION A DIABLO WHITE PAPER AUGUST 2014 Ricky Trigalo Director of Business Development Virtualization, Diablo Technologies
IP SAN BEST PRACTICES
IP SAN BEST PRACTICES PowerVault MD3000i Storage Array www.dell.com/md3000i TABLE OF CONTENTS Table of Contents INTRODUCTION... 3 OVERVIEW ISCSI... 3 IP SAN DESIGN... 4 BEST PRACTICE - IMPLEMENTATION...
HGST Virident Solutions 2.0
Brochure HGST Virident Solutions 2.0 Software Modules HGST Virident Share: Shared access from multiple servers HGST Virident HA: Synchronous replication between servers HGST Virident ClusterCache: Clustered
FOR SERVERS 2.2: FEATURE matrix
RED hat ENTERPRISE VIRTUALIZATION FOR SERVERS 2.2: FEATURE matrix Red hat enterprise virtualization for servers Server virtualization offers tremendous benefits for enterprise IT organizations server consolidation,
Post-production Video Editing Solution Guide with Quantum StorNext File System AssuredSAN 4000
Post-production Video Editing Solution Guide with Quantum StorNext File System AssuredSAN 4000 Dot Hill Systems introduction 1 INTRODUCTION Dot Hill Systems offers high performance network storage products
SUN ORACLE DATABASE MACHINE
SUN ORACLE DATABASE MACHINE FEATURES AND FACTS FEATURES From 2 to 8 database servers From 3 to 14 Sun Oracle Exadata Storage Servers Up to 5.3 TB of Exadata QDR (40 Gb/second) InfiniBand Switches Uncompressed
Data Sheet FUJITSU Storage ETERNUS CD10000
Data Sheet FUJITSU Storage ETERNUS CD10000 Data Sheet FUJITSU Storage ETERNUS CD10000 The ultimate hyperscale storage system for large enterprises ETERNUS CD10000 The ETERNUS CD10000 provides unlimited,
Best Practices for Optimizing Your Linux VPS and Cloud Server Infrastructure
Best Practices for Optimizing Your Linux VPS and Cloud Server Infrastructure Q1 2012 Maximizing Revenue per Server with Parallels Containers for Linux www.parallels.com Table of Contents Overview... 3
Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4
Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4 Solutions for Large Environments Virtualization Solutions Engineering Ryan Weldon and Tom Harrington THIS WHITE PAPER IS FOR
Windows Server 2012 R2 Hyper-V: Designing for the Real World
Windows Server 2012 R2 Hyper-V: Designing for the Real World Steve Evans @scevans www.loudsteve.com Nick Hawkins @nhawkins www.nickahawkins.com Is Hyper-V for real? Microsoft Fan Boys Reality VMware Hyper-V
Building a Flash Fabric
Introduction Storage Area Networks dominate today s enterprise data centers. These specialized networks use fibre channel switches and Host Bus Adapters (HBAs) to connect to storage arrays. With software,
High-Availability Fault Tolerant Computing for Remote and Branch Offices HA/FT solutions for Cisco UCS E-Series servers and VMware vsphere
Table of Contents UCS E-Series Availability and Fault Tolerance... 3 Solid hardware... 3 Consistent management... 3 VMware vsphere HA and FT... 3 Storage High Availability and Fault Tolerance... 4 Quick-start
Virtual SAN Design and Deployment Guide
Virtual SAN Design and Deployment Guide TECHNICAL MARKETING DOCUMENTATION VERSION 1.3 - November 2014 Copyright 2014 DataCore Software All Rights Reserved Table of Contents INTRODUCTION... 3 1.1 DataCore
Microsoft Exchange Server 2003 Deployment Considerations
Microsoft Exchange Server 3 Deployment Considerations for Small and Medium Businesses A Dell PowerEdge server can provide an effective platform for Microsoft Exchange Server 3. A team of Dell engineers
Scientific Computing Data Management Visions
Scientific Computing Data Management Visions ELI-Tango Workshop Szeged, 24-25 February 2015 Péter Szász Group Leader Scientific Computing Group ELI-ALPS Scientific Computing Group Responsibilities Data
Installing Hadoop over Ceph, Using High Performance Networking
WHITE PAPER March 2014 Installing Hadoop over Ceph, Using High Performance Networking Contents Background...2 Hadoop...2 Hadoop Distributed File System (HDFS)...2 Ceph...2 Ceph File System (CephFS)...3
IP SAN Best Practices
IP SAN Best Practices A Dell Technical White Paper PowerVault MD3200i Storage Arrays THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES.
Zadara Storage Cloud A whitepaper. @ZadaraStorage
Zadara Storage Cloud A whitepaper @ZadaraStorage Zadara delivers two solutions to its customers: On- premises storage arrays Storage as a service from 31 locations globally (and counting) Some Zadara customers
HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN
HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN Table of contents Executive summary... 2 Introduction... 2 Solution criteria... 3 Hyper-V guest machine configurations...
MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220
MESOS CB220 Cluster-in-a-Box Network Storage Appliance A Simple and Smart Way to Converged Storage with QCT MESOS CB220 MESOS CB220 A Simple and Smart Way to Converged Storage Tailored for SMB storage
The IntelliMagic White Paper: Storage Performance Analysis for an IBM Storwize V7000
The IntelliMagic White Paper: Storage Performance Analysis for an IBM Storwize V7000 Summary: This document describes how to analyze performance on an IBM Storwize V7000. IntelliMagic 2012 Page 1 This
Distribution One Server Requirements
Distribution One Server Requirements Introduction Welcome to the Hardware Configuration Guide. The goal of this guide is to provide a practical approach to sizing your Distribution One application and
Parallels Cloud Server 6.0 Readme
Parallels Cloud Server 6.0 Readme Copyright 1999-2012 Parallels IP Holdings GmbH and its affiliates. All rights reserved. Contents About This Document... 3 About Parallels Cloud Server 6.0... 3 What's
VMware Virtual SAN Design and Sizing Guide for Horizon View Virtual Desktop Infrastructures TECHNICAL MARKETING DOCUMENTATION REV A /JULY 2014
VMware Virtual SAN Design and Sizing Guide for Horizon View Virtual Desktop Infrastructures TECHNICAL MARKETING DOCUMENTATION REV A /JULY 2014 Table of Contents Introduction.... 3 VMware Virtual SAN....
Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1
Performance Study Performance Characteristics of and RDM VMware ESX Server 3.0.1 VMware ESX Server offers three choices for managing disk access in a virtual machine VMware Virtual Machine File System
PCIe Over Cable Provides Greater Performance for Less Cost for High Performance Computing (HPC) Clusters. from One Stop Systems (OSS)
PCIe Over Cable Provides Greater Performance for Less Cost for High Performance Computing (HPC) Clusters from One Stop Systems (OSS) PCIe Over Cable PCIe provides greater performance 8 7 6 5 GBytes/s 4
Part 1 - What s New in Hyper-V 2012 R2. [email protected] Datacenter Specialist
Part 1 - What s New in Hyper-V 2012 R2 [email protected] Datacenter Specialist Microsoft Cloud OS Vision Public Cloud Azure Virtual Machines Windows Azure Pack 1 Consistent Platform Windows Azure
Performance Evaluation of VMXNET3 Virtual Network Device VMware vsphere 4 build 164009
Performance Study Performance Evaluation of VMXNET3 Virtual Network Device VMware vsphere 4 build 164009 Introduction With more and more mission critical networking intensive workloads being virtualized
Converged storage architecture for Oracle RAC based on NVMe SSDs and standard x86 servers
Converged storage architecture for Oracle RAC based on NVMe SSDs and standard x86 servers White Paper rev. 2015-11-27 2015 FlashGrid Inc. 1 www.flashgrid.io Abstract Oracle Real Application Clusters (RAC)
Moving Virtual Storage to the Cloud. Guidelines for Hosters Who Want to Enhance Their Cloud Offerings with Cloud Storage
Moving Virtual Storage to the Cloud Guidelines for Hosters Who Want to Enhance Their Cloud Offerings with Cloud Storage Table of Contents Overview... 1 Understanding the Storage Problem... 1 What Makes
N5 NETWORKING BEST PRACTICES
N5 NETWORKING BEST PRACTICES Table of Contents Nexgen N5 Networking... 2 Overview of Storage Networking Best Practices... 2 Recommended Switch features for an iscsi Network... 2 Setting up the iscsi Network
Parallels Cloud Server 6.0
Parallels Cloud Server 6.0 Readme September 25, 2013 Copyright 1999-2013 Parallels IP Holdings GmbH and its affiliates. All rights reserved. Contents About This Document... 3 About Parallels Cloud Server
http://support.oracle.com/
Oracle Primavera Contract Management 14.0 Sizing Guide October 2012 Legal Notices Oracle Primavera Oracle Primavera Contract Management 14.0 Sizing Guide Copyright 1997, 2012, Oracle and/or its affiliates.