CapSmart-IPS Caprari Inteligent Pressure System
|
|
|
- Griffin Walters
- 9 years ago
- Views:
Transcription
1 CapSmart-IPS Caprari Inteligent Pressure System Owner s manual 240 V~ 50 Hz 240V, 10 Amps Rel. 1.1
2 2 CAUTION: READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE INSTALLING OR USING THE PRODUCT The manufacturer guarantees this product for a period of 24 months as of the date of sale; the device must be returned together with this instruction manual, with the date of installation and programmed parameters noted in the last page of this document. The guarantee will be rendered null and void if the device is tampered with, disassembled, or damaged due to causes attributable to incorrect use and/or improper installation, if it is used for purposes other than as specified, if it is installed in unsuitable environmental conditions or if it is connected to an electrical installation that does not comply with current standards. The manufacturer declines all liability in the event of damage to objects and/or physical injury caused by failure to install the necessary electrical safety devices upline of the device, or due to an unprofessional installation. Installation and maintenance of this device must be performed by specialist personnel, who is able to fully understand the contents of this instruction manual. All operations performed with the device cover removed must be performed with the power mains disconnected. As there are no concrete reasons for removal of the electronic board, take into account that some of the board parts remain live for a few minutes also after disconnecting the device from the mains. The manufacturer declines all liability in the event of damage to objects and/or physical injury caused by failure of an internal protection device, with the exception of the refund of the device, if still covered by the guarantee. This device complies with the directive ROHS 2002/95/EC. The crossed-out wheelie bin symbol shown above indicates that, in respect of the environment, the device must not be disposed of as public waste at the end of its lifetime. Dispose of the device and packaging material in compliance with local legislation.
3 3 INDEX LAYOUT-DIMENSION- IDENTIFICATION DESCRIPTION.. 5 TECHNICAL DATA....6 FUNCTIONS PROTECTIONS....6 INSTALLATION HYDRAULIC CONNECTION..7 ELECTRICAL CONNECTION START-UP...11 PROGRAMMING INTERFACE DESCRIPTION.. 12 KEYDESCRIPTION.. 12 DESCRIPTION OF PARAMETERS AND SCREENS..12 ALARMS.. 16 TROUBLESHOOTING MAINTENANCE.18
4 LAYOUT - DIMENSIONS - IDENTIFICATION 4
5 5 DESCRIPTION CapSmart-IPS (Short for Inteligent Prerssure System) is an electronic control device for single phase electric pumps which enables automatic start-up and shutdown of the pump, protecting it in the event of adverse operating conditions (failure of water supply, motor overload, risk of ice). CapSmart-IPS can operate on various systems: - with a single electric pump, - in a twin pump system in which the two alternate automatically - in conjunction with a variable speed device (CapSmart-VFD) for the set-up of constant pressure pumping units. CapSmart-IPS is programmable to operate on the basis of two different principles: - mode P+F (pressure + flow) = in this mode, the pump is started up following a fall in pressure, when the minimum set threshold is reached (Pmin); the pump operates until the water supply runs out and there is zero flow through the device. In this condition the resulting pressure in the system will correspond to the maximum pump head. - mode P+P (pressure + pressure) = in this mode the pump operating mode is controlled within two pressure levels (Pmin e Pmax); when the lower pressure threshold is reached (Pmin) the pump is started up, while it is stopped when the upper pressure threshold (Pmax) is reached. In this configuration, the use of an expansion vessel is essential, sized according to the system requirements and type of pump. In both operating modes, the device protects the pump from dry running in the absence of water on intake, by means of a combined control on flow and pressure. Operation of twin pumping units is admissible only in "P+P" mode.
6 6 TECHNICAL DATA Mains power: single phase 240Vac +5, -15% - 50/60Hz Motor output:... single phase 240V~ Maximum motor power W 3Hp Maximum motor phase current: 10 Amps Maximum admissible pressure: KPa (10 bar) Maximum liquid temperature.. 30 C Max. Ambient temperature...55 C Pressure drop: 0.7 Bar at 100 l/min Hydraulic connection 1 BSP M-M Protection rating: IP 65 Weight 0.7 Kg Dimensions.225x150x115 mm Type of action...1 (according to EN ) FUNCTIONS Automatic start-up and shutdown of the pump. Operation with twin units operating alternately. Easy and precise control of working pressures via the display. Protection against dry running with automatic reset Installable in both horizontal and vertical positions Digital indicator of pressure and absorbed current on display Operating status indicator leds (mains, error, pump running) Digital input for float or remote control connection Configurable relay output Removable electrical terminals to facilitate wiring. Alarm log PROTECTIONS Dry-running Motor current control protection Overpressure cut-out Anti-freeze protection Prevention of mechanical pump part seizure
7 7 INSTALLATION HYDRAULIC CONNECTION: CapSmart-IPS must be installed on the pump delivery in a horizontal or vertical position, in observance of the flow direction indicated by the arrow on the cover. The water on the pump outlet passes through the device for subsequent distribution to the various utilities. The water entering the CapSmart-IPS must be free of impurities and/or other substances that could prevent movement of the check valve on the interior. To minimise this problem special filters should be fitted on the pump intake. Install a small expansion vessel (1-2 litres) downline of CapSmart-IPS, to limit restarts caused by small leaks, the presence of which is normal on most systems. The pre-load valve of the expansion vessel must be suitable for the set pressure values. This provision also helps to improve constant performance levels in the event of low water demands by the system (e.g. washing machines, WC flushes, etc.). It is essential that no check valve is installed between CapSmart-IPS and the electric pump or between the device itself and the utilities, as this may cause device malfunctions. However, a check valve may be fitted in the electric pump intake line to avoid drainage at the time of shutdown. The device should not be installed in pits or watertight enclosures where there is a strong risk of condensation. CAUTION: when the pump stops the pipes might be still under pressure; therefore, before any intervention, it is advisable to discharge the system by opening a tap. CAUTION: this device is not to be considered a mechanical pressure reducer and therefore all system parts must be sized according to the maximum supply pressure of the pump. H EXAMPLE OF INSTALLATION ON SINGLE ELECTRIC PUMP: CapSmart-IPS can be fitted on submerged or surface pumps. Pressure settings must take into account the water column (H) on outlet from the device, considering 0.1 Bar pressure per metre of water column. EXAMPLE OF INSTALLATION IN TWIN BOOSTER SETS Connect the intake lines of the pumps to a common manifold and install one CapSmart-IPS on the delivery line of each electric pump. The device outlet couplings must be connected to a single delivery manifold, which must be connected to the expansion vessel.
8 8 ELECTRICAL CONNECTION: Insert the electric wires in the cable clamps, observing the correct order of assembly for all components Tighten down the threaded nuts to avoid traction and rotation of the cables from the exterior. The central cable clamps for the auxiliary contact is blank; if you wish to insert a wire for remote control (or electric float), pierce the plastic nut by means of a screwdriver after removing the nut from the unit. For electrical connections use the terminals supplied with the device CAUTION: insert the terminals, positioning them so that the cable tightening screws are not adjacent! CORRECT WRONG MOTOR 10 A max. N L LINE 240V 50Hz N L
9 9 LINE CONNECTION The device power supply is single phase at 240 Volt 50 Hz. The electrical system to which the device is connected must comply with current standards and must therefore be fitted with: - automatic thermal magnetic circuit breaker with high breaking power and trip current in proportion to the power of the pump installed - earthing connection with total resistance in conformity with local standards and in any event no more than 100Ω. If the device is used in swimming pools, fountains, or garden ponds, a residual current circuit breaker type "A" must be installed, with I n=30ma If the device is not equipped with a power cable and plug, install another device that ensures omnipolar disconnection from the mains with a contact opening gap of at least 3 mm. If the terminals supplied are not used, the faston terminals must be crimped by specialist personnel using special pliers. The recommended cable section is 1.5mm 2, compatible with electric pumps up to 16A. The type of electric cable must correspond to the conditions of use (use in domestic rooms, dry or wet, for installation indoors or outdoors). ELECTRIC PUMP CONNECTION CapSmart-IPS can be installed on single phase pumps with 240Vac power supply, already fitted with capacitor. Therefore at the time of electrical connections, ensure that the terminals in the electrical compartment of the motor are connected according to the instructions of the electric pump manufacturer. The figure alongside shows a typical example of connection. If the terminals supplied are not used, the faston terminals must be crimped by specialist personnel using special pliers. The recommended cable section is 1.5mm2. The type of electric cable must correspond to the conditions of use (use in domestic rooms, dry or wet, for installation indoors or outdoors). Also observe the installation limits as declared by the manufacturer of the electric pump connected to CapSmart-IPS. CAUTION: - all electrical connections must be made by specialised personnel - incorrect connections of the electric motor can cause damage to the device or the pump motor itself. - failure to observe the instructions in this section can cause serious damage and/or physical injury and releases the manufacturer from all liability. - in the event of damage to the power cable or the cable between CapSmart-IPS and the electric pump, it must be replaced exclusively by the device manufacturer or assigned and suitably qualified personnel, to prevent risks to objects and persons.
10 10 AUXILIARY CONNECTOR CONNECTION CapSmart-IPS is equipped with a connector to make auxiliary contacts available for additional functions, interfacing the device with other external equipment. The functions of each terminal depend on the settings of the parameter Aux. Con. According to the diagram below. Functions 1 and 4 are available only if the operating mode is set to P+P (pressure+pressure). * Further information regarding the set-up of twin booster sets can be found at the end of this manual, in appendices A and B. AUXILIARY CONNECTOR Setting Mode admitted Associated function: Aux. Con. 0 P+F / P+P None, inputs and outputs disabled 1 P+P Combination of two CapSmart-IPS units in a twin pumping system with automatic alternation. 2 P+F / P+P Availability of an input to enable operation (for example of an external float) and a relay output for alarm status signals. 3 P+F / P+P Availability of an input to enable operation (for example of an external float) and a relay output for motor operation signals. 4 P+P Combination of one CapSmart-IPS with an inverter CapSmart- VFD for the set-up of a constant pressure twin pumping system with a reserve pump. DESCRIPTION OF FUNCTIONS OF AUXILIARY CONTACTS: Parameter "Aux. Con. = 0 In this mode, all functions of the auxiliary contact are disabled. Parameter "Aux. Con. = 1 Operation in twin set mode with two CapSmart-IPS In this mode two devices can be connected to operate in an alternating twin booster set. If pressure falls, the "master" pump is started up first, followed by the "slave" pump (when required); shutdown of the pumps is simultaneous when the maximum operating pressure is reached (Pmax). Terminals 1 to 4 are used for the connection of two devices while terminals 5 and 6 provide a relay output that is activated in the event of an alarm. The parameter "Aux. Con. can only be set to 1 if the current operating mode is P+P (pressure+pressure). ALARM OUTPUT ALARM OUTPUT
11 11 Parameter "Aux. Con. = 2 External enable and alarm signal. ALARM OUTPUT In this mode, an external electrical device (e.g. float, timer, switch, etc.) can be connected between terminals 1 and 3, to enable remote operation of the pump. In this mode the motor is only started up if the external contact between terminals 1 and 3 is closed. Terminals 5 and 6 provide a relay output that is activated in the event of an alarm. Jumpers must be wired onto terminals 2 and 4. EXTERNAL CONTACT Parameter "Aux. Con. = 3 External enable and pump operation signal. In this mode, an external electrical device (e.g. float, timer, switch, etc.) can be connected between terminals 1 and 3, to enable remote operation of the pump. In this mode the motor is only started up if the external contact between terminals 1 and 3 is closed. Terminals 5 and 6 provide a relay output that is activated when the pump is running; this signal enables the control of external devices that have to operated in conjunction with the electric pump (for example a batching system for chlorine, fertilizer, detergents etc.). Jumpers must be wired onto terminals 2 and 4. PUMP OPERATION OUTPUT EXTERNAL CONTACT Parameter "Aux. Con. = 4 Combination with inverter device Sirio ALARM OUTPUT When the parameter "Aux. Aus. is set to 4 CapSmart- IPS can be interfaced with an inverter in the range CapSmart-VFD to produce a hybrid pressurisation unit, i.e. a variable speed pump and a fixed speed pump that intervenes as a backup to the main pump only in the event of increased water demands by the system. During routine operation, the system demands are normally met by the pump with the CapSmart-VFD inverter, which is always started up first. When the demand for water increases to such a point that the first pump is no longer sufficient, the fixed speed pump, installed together with CapSmart-IPS is then started up. Terminals 1 to 4 are used for the connection of two devices while terminals 5 and 6 provide a relay output that is activated in the event of an alarm. The parameter "Aux. Con. can only be set to 4 if the current operating mode is P+P (pressure+pressure). CAUTION: incorrect connections of the auxiliary contact could cause irreparable damage to the device! Take great care when making the connection.
12 12 START-UP CAUTION: on initial start-up, fill the pump intake line before powering up the system! After making all the electrical connections and ensuring the correct condition of all components, close the unit cover and power up the system. CapSmart-IPS starts up the pump automatically to enable circuit filling. If the pump does not start, or anomalous vibrations are detected, ensure correct connection of the pump and relative capacitor. To facilitate the filling of the electric pump, press and hold the + key on the main screen to override pump operation without intervention of the dry-running protection ( Manual mode). After setting all data in the device, note them on the relative form found at the end of this manual for future reference and to maintain the guarantee. PROGRAMMING: 1 INTERFACE DESCRIPTION 1. Display with digital pressure indicator, error display, configuration menus. 2. Programming keys 4 3. Green mains power ON indicator light (LINE) 5 4. Red error indicator light (FAILURE) 3 5. Yellow "pump running" indicator light (PUMP ON) 2 KEY DESCRIPTION Arrow/reset: scrolls forward through menus and performs unit reset in the event of alarms and/or errors + key: increments the parameter value currently on display; enables device operation override (starts pump as an override command and temporarily disables the dry-running protection to facilitate loading on initial start-up). - key: decreases the parameter value currently on display; shows the absorbed current (optional) DESCRIPTION OF PARAMETERS AND SCREENS The menu is divided into two levels: the user level and the installer level. The user level is usually visible during normal operation and enables the user to control the system operating status, reset any errors and modify the language. To access the installer level, where the various operating parameters can be set, press keys + and - simultaneously for 5 seconds.
13 13 USER PARAMETERS: These parameters are normally accessible when the device is powered. Main screen: during normal operation of CapSmart-IPS, the display shows the device status. The top line displays the pressure measured in the system, while the bottom line shows the motor current absorption. In this screen, press and hold the key + to override pump operation also when there is no water, temporarily disabling the dry-running protection to enable the pump to be filled. When the device is configured to operate as part of an alternating twin pumping unit, the bottom line shows the "master" or "slave" status by means of the letter "m" or "s". Language: the language of the menus and alarm messages can be personalised as required. Use keys + and to modify the parameter value. INSTALLER PARAMETERS: These parameters are located in concealed screens and are normally only modified during the installation phase. To access these pages, press and hold + and - simultaneously for 5 seconds. After accessing the concealed menu, use the arrow key >> to scroll through the screens and keys + and - to modify the parameters. To return to the main screen, press and hold keys + and - simultaneously for 5 seconds. Operating mode: this parameter enables the user to set the operating mode implemented by CapSmart-IPS to control pump start-up and shutdown. In mode P+F (pressure+flow) the pump is started up when the pressure falls below the value set in Pmin (start-up pressure) and is stopped when the water flow through the device is virtually zero. In this condition the resulting pressure in the system will correspond to the maximum head of the pump installed. In mode P+P (pressure+ pressure) the pump is started up at the value set in Pmin and is then stopped when the system pressure reaches the value Pmax (stop pressure). In this mode, the installation of an expansion vessel is essential, sized according to the system specifications. In both operating modes, the dry-running protection is enabled, and trips when the water flow is zero and the system pressure is below the value Pmin. Operation within twin booster sets is only admissible in mode P+P and consequently, the settings of the parameters Aux. Con., Pmax and Pmin2 depend on the pre-set operating mode. Pmin : this parameter represents the minimum pressure at which the pump is started. The parameter can be set from 0.5 to 8.0 Bar. The factory setting is 1.5 bar. Use keys + and - to modify the set value.
14 14 Pmax : this parameter is only available when the operating mode is set to P+P (pressure+pressure) and represents the electric pump stop pressure. The parameter can be set from 1.0 to 9.0 Bar and in any event at least 0.3 Bar higher than the set value of Pmin. Use keys + and - to modify the set value. Pmin2 : this parameter is only available when the operating mode is set to P+P and the parameter Aux. Con. is set to 1 to enable operation of twin booster sets. This parameter defines the secondary (slave) pump start-up pressure when the primary (master) pump can no longer meet the system demands. The parameter can be set from a minimum of 0.5 Bar to a maximum value equal to the pressure Pmin-0.2 Bar. The factory setting is 1.2 bar. Use keys + and - to modify the set value. Auto-reset interval: during operation of the pump, if water supply on intake fails temporarily, CapSmart-IPS shuts off the power supply to the motor to avoid any damage. This screen enables the user to set after how many minutes the device should auto-reset to check renewed availability of water on intake. If the attempt is successful, CapSmart-IPS exits automatically from the error condition and system returns to operative status; otherwise another attempt is made after the same time interval. The maximum settable interval is 180 minutes (recommended interval: 60 min.). Use keys + and to modify the parameter value. N auto-reset tests: this parameter defines the number of attempts made by CapSmart-IPS to try and resolve a shutdown caused by dry running conditions. When this limit is exceeded, the system shuts down and user intervention is required. The auto-reset is disabled if this value is set to zero. The maximum admissible number of attempts is 10. Use keys + and to modify the parameter value. Delay on stop: this parameter enables the user to define after how many seconds the electric pump is stopped following closure of all utilities in mode P+F. At low flow rates, if frequent pump start-ups and shutdowns occur, increase the shutdown delay to render operation more uniform. An increase to this parameter may also be useful to eliminate excessively frequent activation of the dry-running protection, especially in the case of submerged pumps or on those with self-priming problems. The factory setting is 10 seconds, and may be increased to a maximum of 120 seconds. Use keys + and - to modify the stop delay. 24H anti-seizure protection this parameter enables the activation of a function that automatically starts up the pump after 24 hours of disuse. If this function is activated, and the pump is not started up for 24 hours, CapSmart-IPS overrides to a cycle of 15 seconds to prevent system disuse from leading to mechanical seizure of parts (e.g. the seal), maintaining system efficiency. 4 C ice protection: this parameter enables activation of a function that may help prevent damage due to lowering of ambient temperatures and the risk of ice formation. In particular, if the ambient temperature falls below 4 C, CapSmart-IPS starts up the pump every 30 minutes for a duration of 15 seconds, to avoid, when possible, the rapid freezing of the water inside the pump. CAUTION: although this function can reduce the risk of damage caused by ice, it is good practice not to use CapSmart-IPS and the electric pump in environments where temperatures can fall below 4 C. The activation of this function is not sufficient to guarantee operation and protection of the system if temperatures are close to or below 0 C!!
15 15 Imax : this optional parameter enables entry of the maximum current absorbed by the electric pump in routine conditions, to enable shutdown of the motor in the event of excessive absorption. The motor is also shut down event if the current read during operation is below 0.5 A following interruption of the connection between the motor and CapSmart-IPS. The trip time of the current overload safety device is inversely proportional to the entity of the overload in progress; therefore a slight overload will lead to a more delayed trip time while a more significant overload will accelerate the trip time. The parameter is settable from 0.5 to 16 A by means of the keys + and -. To deactivate the current control protection of the motor, press the key - until the text OFF appears on display. CAUTION: the factory setting is OFF and therefore a maximum current value must be set to activate the protection. Auxiliary Contact: this parameter enables the user to assign a specific function to the auxiliary contacts available on CapSmart-IPS according to the scheme below: Aux. Con. Description 0 No function activated for auxiliary contacts 1 Enables communication between two CapSmart-IPS units within a twin booster set with automatic alternation of pumps 2 Sets up the auxiliary contact for an external enable signal (e.g. float, timer, irrigation controller) and enables the relay output (terminals 5 and 6 on the terminal board) for any error signals. The relay contact closes in the event of an alarm. 3 Sets up the auxiliary contact for an external enable signal (e.g. float, timer, irrigation controller) and enables the relay output (terminals 5 and 6 on the terminal board) for pump operation signals. The relay contact closes while the pump is running. 4 Enables communication between a CapSmart-IPS unit and an inverter CapSmart-VFD within a twin booster set. Limit pressure: this parameter defines a pressure threshold over which the overpressure protection is activated. The factory setting is OFF, to indicate that the protection is disabled. To set a limit pressure, use keys + and -. To disable the function, press the "+" key until the text OFF is displayed. Deactivation threshold: when CapSmart-IPS is configured to operate in conjunction with an inverter device Sirio (mode set to P+P and Aux. Con. set to 4 ), this parameter can be set to define the secondary pump deactivation threshold. The secondary pump where the CapSmart-IPS is installed, is started up, on request of the inverter controlling the primary pump, when the pressure falls below Pmin. The secondary pump is shut down when the required flow falls below a limit set in this parameter. The factory setting is 20 and the parameter can be set from 10 to 50. The setting of this threshold depends on the type of pumps used, considering that a higher value of this parameter corresponds to a quicker shutdown of the auxiliary pump, while a lower threshold value maintains the auxiliary pump in operation even when the flow rate falls to low values.
16 16 Alarm log 1 : in this screen the user can read the number of alarms that have tripped due to activation of the dry-running protection (DR) and the pressure overload device (OP). These data can be checked in the event of a malfunction. Alarm log 2 : in this screen the user can read the number of alarms that have tripped due to activation of the current overload protection (OL) and the ice protection (IP). These data can be checked in the event of a malfunction. Hour counter: this screen displays the total operating hours of CapSmart- IPS (in terms of the time for which the device has been connected to the electric power supply). If the key + is pressed on this page, the number of pump operating hours is displayed. ALARMS Dry running: this message appears when the system is shut down following absence of water on pump intake. If the auto-reset function is enabled, Brio Top CapSmart-IPS automatically attempts to restart and check for renewed availability of water. To remove the error message from the display immediately, simply press the central key reset. Current Overload: this alarm is displayed when electric pump absorption exceeds the maximum set current as entered in the parameter Imax; this may occur following intensive use of the electric pump, continuous restarts at close intervals, problems with the motor windings, seizure of the pump rotor or following problems with the electrical connection between the motor and CapSmart-PS. If this alarm trips frequently, arrange for the system to be checked by the installer. To remove the error message from the display immediately, simply press the central key reset. Overpressure: when this alarm trips, this means that CapSmart-IPS has detected a system pressure value over the value set in the parameter Plimit. This may occur in applications with the pump under load conditions, i.e. when the pump pressure is added to the filling pressure on inlet. If the error occurs frequently, try to increase the parameter Plimit or contact the installer for assistance. To remove the error message from the display immediately, simply press the central key reset.
17 17 TROUBLESHOOTING When one of the system valves is opened the pump does not start or starts only after a few seconds. The set Pmin value is too low, or a check valve has been fitted downline of the device. Check the setting of the parameter Pmin. If the parameter Aux. Con. is set to 2 or 3 and an electric float is used, check to ensure correct operation. If no electric float is used, check that the jumper is wired on the relative terminals. Ensure correct connection between CapSmart-IPS and the electric pump The pump does not stop The check valve inside CapSmart-IPS may be blocked in the open position; ensure correct valve movement and remove any foreign bodies by means of compressed air if necessary. The sensor reading the valve position is faulty; arrange for the device to be checked by the manufacturer. On closure of the valves, the pump stops but restarts after a few seconds without any leaks from the system. The difference between the values Pmin and Pmax is too small, and the pressure drop that occurs on pump shutdown is sufficient to enable restart. Increase the value Pmax or reduce the value Pmin. Increase the size of the expansion vessel installed. The pump starts and stops continuously. There are leaks from the system. Check the various hydraulic connections. Check on display if there are any pressure drops when the valves are closed. Check for the possible presence of dirt in the check valve of CapSmart-IPS preventing total closure, and if necessary clean by means of a compressed air jet. Install a small expansion vessel on outlet from CapSmart-IPS. The device frequently signals dry running conditions. The pump intake hose, during periods of system disuse, drains preventing pump filling and subsequent restart. Check sealing efficiency of the base valve (if fitted). With very low water flow rates, pump operation is irregular. The water flow rate is too low, and is thus not detected by the device, with consequent pump shutdown. Install a small expansion vessel (1-2 litres) to enhance system flexibility and reduce the number of restarts. The system pressure has risen above the set value in Pmax. If the ice protection or mechanical seizure protection devices have triggered, pressure may increase over the set values as the pump is operated in override for 15 seconds, regardless of the values set in Pmax and Pmin.
18 18 The device does not turn on The electronic board may be damaged; arrange for the device to be checked by the manufacturer. MAINTENANCE: Your CapSmart-IPS has been designed to reduce maintenance requirements to a minimum. Always observe the following instructions to ensure prolonged efficiency of the device: - never allow the device to reach temperatures below 4 C; if this is not possible, ensure that all the water in the circuit is drained to prevent damage to the plastic housing of the device if ice forms; - if the pump is equipped with filters on intake, check their condition periodically; - always ensure that the cover is closed properly to avoid the ingress of water from outside; - disconnect the power and drain water from the system when the system is not to be used for a prolonged period; - before using the device with liquids other than water, contact the manufacturer for further information; - never perform work with the device open; - before removing the device cover, wait for 3 minutes to enable discharge of the capacitors. CAUTION: the device does not contain components that may be repaired or replaced by the final user. Therefore do not remove the protection cover of the electronic board to avoid rendering the guarantee null and void. Date of installation././. Installer Client Pump brand-model Serial N CapSmart-PS FACTORY SETTINGS ON INSTALLATION Mode Pmin Bar Pmin2 Bar Pmax Bar Reset Minutes Reset Test Prot.24H Prot.4 C Stop delay Seconds Imax A Plimit Bar Aux. Con. Deact. thresh. Notes
19 19 Installation and connection of twin booster sets CONNECTION TERMINAL INSTALLATION: install each CapSmart-IPS on the delivery line of the respective electric pump. Connect the outlet connector of each device to the delivery manifold without inserting any type of check valve. Connect the intake lines of the pumps to the common suction manifold, inserting a check valve for each pump to prevent drainage when stopped. CapSmart-IPS can be mounted vertically or horizontally. CONNECTION: the connection between the two Brio Top devices is by means of an unshielded cable (4x0.5 mm 2) as shown in the diagram alongside. the maximum length of the cable is 100 cm including stripped sections. A pre-assembled connection cable is available, with terminals and numbered wires (code no. SR-CBL4X05-100). The operating mode must be set to P+P and the parameter Aux. Con. to 1. MASTER STATUS: when the device is MASTER it is sensitive to variations in system pressure, and is therefore able to start and stop the electric pump according to system demands. SLAVE STATUS: when the device is SLAVE the letter s appears on the bottom line of the display; in this condition, the pump is only started if the pressure falls below the value set in the parameter Pmin2. OPERATION: when switched on, the first device that manages to assume priority is assigned the status of MASTER while the other becomes SLAVE. On opening of the utilities, the MASTER device starts up the pump first; if the water demand is such that operation of one pump only is not sufficient, the second pump (SLAVE device) is started up. On progressive closure of utilities, the rise in system pressure leads to simultaneous shutdown of the two pumps at the value set in Pmax.. After shutdown the status of MASTER is transferred to the other device, to ensure that there is continuous alternation of which pump is started up first. In the event of a fault or error on one of the two CapSmart-IPS devices, the other is automatically assigned the status of Master and starts to operate independently. If the current MASTER device shuts down due to a power failure, or blocks due to a fault, system control is transferred to the SLAVE device, which then immediately becomes the new MASTER. The programmed values of Pmin, Pmin2 and Pmax must be the same on both devices.
20 20 Installation and connection of twin booster sets with CapSmart-VFD inverter CONNECTION TERMINAL INSTALLATION: install the CapSmart-IPS on the delivery line of the secondary pump and the CapSmart-VFD inverter on the main variable speed pump. Connect the outlet connector of each device to the delivery manifold without inserting any type of check valve. Connect the intake lines of the pumps to the common suction manifold, inserting a check valve for each pump to prevent drainage when stopped. CapSmart- IPS and CapSmart-VFD can be mounted vertically or horizontally. ALARM OUTPUT CONNECTION: the connection between the CapSmart-IPS and CapSmart-VFD devices is by means of an unshielded cable (4x0.5 mm 2) as shown in the diagram alongside. The maximum length of the cable is 100 cm including stripped sections. A pre-assembled connection cable is available, with terminals and numbered wires) code no. SR- CBL4X05-100). For CapSmart-IPS the operating mode must be set to P+P and the parameter Aux. Con. to 4. In the case of CapSmart-VFD it is sufficient to set the parameter Aux. Con. to 1. OPERATION: when switched on, the CapSmart-VFD device always sets to MASTER status and is assigned the role of main controller. On opening of the utilities, CapSmart-VFD starts up the pump first; if the water demand is such that operation of one pump only is not sufficient, the second pump with CapSmart-IPS (SLAVE device) is started up. On progressive closure of the utilities, the reduction in the system flow rate leads first to the shutdown of the secondary pump on which the CapSmart-IPS is installed, later followed by the variable speed pump on which CapSmart-VFD is installed. The flow rate level at which the secondary pump is shut down depends on the value set in the parameter Deactivation threshold of the CapSmart-IPS; a higher value in this parameter leads to a quicker deactivation of the second pump, while a lower value maintains the SLAVE pump in operation even at lower flow rates. If the CapSmart-VFD, i.e. the current MASTER device, shuts down due to a power failure, or blocks due to a fault, system control is transferred to the CapSmart-IPS device, which then immediately becomes the new MASTER to enable the system to continue operation. However, in this case operation at constant pressure is no longer guaranteed, as there is no variable speed device. It is recommended to install an expansion vessel of at least 5-8 litres, to prevent, in the event of a fault on the CapSmart-VFD and device, CapSmart-IPS from activating excessively frequent start-ups. The programmed values of Pmin and Pmax must be the same on both devices.
21 21 CE DECLARATION OF CONFORMITY It is hereby declared that the machine specified herein, according to the specific design, type of construction and version released onto the market, complies with the essential health and safety requirements of EC directives. In the event of modifications to the machine without prior authorisation, this declaration will be rendered null and void. MODEL: CapSmart-PS TYPE: BT-XX-X-XX-XXX DIRECTIVE: WITH REFERENCE TO: MARKING YEAR: 2006/95/EC EN : LVD 2004/108/EC EMC EN :2007 EN : Month, 10 Feb 2011 Made for :- Caprari Pumps Australia Pty Ld. 3 Jeanes St BEVERLEY South Australia 5009 Declaration :- Mr. Demetrio Bertazzo Italtecnica srl Viale Europa Tribano (PD) Italy
22 22 Caprari Pumps Australia, 3 Jeanes St Beverley South Australia Tel Fax
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Water Tec of Tucson Water Systems
Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com
SMM. Installation Operation Maintenance
SMM Configuration SMM Module for Scroll Units, H Generation Installation Operation Maintenance 1 0 L80 IM 022 GB SMM Configuration SMM Module for Scroll Units, H generation Foreword These installation,
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR
CAUTION! Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR NOTE: read the manual prior to commencement of use. For safety reasons, the pump can only be operated by
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
PANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: [email protected] Website: www.centrair.ca
MODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual
Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector
Thermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
REGTRONIC OPERATING INSTRUCTIONS
REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:
Maxi Pressurisation Units (Maxi, Maxi Plus & HP)
Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5
SELECTION, APPLICATION & MAINTENANCE
DIESEL PROTECTION SYSTEMS TPZ Engine Air Intake Shut Down Valves (Combined Automatic Overspeed and Air Pressure Operated Shut Down Bendix Types) SELECTION, APPLICATION & MAINTENANCE Valve Numbers TPZ-101
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
Wilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions
Wilo SP Series Submersible Sump Pumps ECS ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
Automatic start of a generator
Automatic start of a generator General description This application note will help you to set your Xtender for an automatic start of a generator as per different parameters such as the output power, the
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
PC1130 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
Submersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps Troubleshooting Submersible Pumps Fuse overload or circuit breaker trips when motor is started 1. Incorrect line voltage. Check the line
series 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N
Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM ISO 9 No. CLEFFI / GB replaces / GB Function Pressure reducing valves are devices which, when installed
Application Engineering
Application Engineering February 2011 Electronic Unit Controller Table of Contents 1. Introduction and Features... 2 1.1 Technical Specifi cations... 3 1.2 Pressure Probe Error Bypass... 3 1.3 Bump Start...
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Operating Instructions
Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.
PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Operational Overview and Controls Guide
DOCUMENT: ECSEQ2-1 EFFECTIVE: 02/14/07 SUPERSEDES: 02/26/03 Operational Overview and Controls Guide Standard Two or Three Pump Type VFD Booster Controls 6700 Best Friend Road. Norcross, GA 30071. (770)
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps
HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps Operation and Maintenance Manual Model: 71028004 Applies to: Single Circuit Water-to-Water Twin Circuit Units Without DDC Controls MAMM WHSP
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Communication bridge Xcom-MS User Manual
Communication bridge User Manual Copyright 2011 Studer Innotec SA - V1.0.1 Communication bridge : User Manual V1.0.1 Copyright 2011 Studer Innotec SA About the software This document applies to the software
Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS
1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding with the installation,
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
GREISINGER electronic GmbH
T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: [email protected]
Electric Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
EC DECLARATION OF CONFORMITY FOR MACHINES
EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) Manufacturer: Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 770 mod. operator is built to be integrated
4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No
6. 6.1 and info (Menu 4) NB are shown in the event of unit faults or irregular operation Check the Current list (Menu 4) for alarm messages and refer to the list of alarms given at the end of these instructions.
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +44 (0)1527 406800 Fax:
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Operation Manual. Trash Water Pump - ARTIKEL 50788. Read and follow the operating instructions and safety information before using for the first time.
Operation Manual Trash Water Pump - ARTIKEL 50788 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments,
LC/LCD ranges level controllers
GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice
Water Priming Mode Purge air from plumbing system. How do I solve ER-3 WATER PRIME: TIPS ON FILLING SPA IMPORTANT NOTE WARNING
Water Priming Mode Purge air from plumbing system TIPS ON FILLING SPA Before filling remove spa skirt and be sure that all valves in the plumbing system are fully open to maximise the amount of air that
PC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
FLEXIT S4 R S6 R S7 R
94111E-05 2005-10 FLEXIT S4 R S6 R S7 R User Manual Air Handling Unit Cabinet Models with Heat Recovery - Rotor Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 2.1 Heating
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS D-Series Engine Automatic Overspeed Shut Down Valves (Spindle Types with Air Pressure and Manual Shut Down Options) SELECTION, APPLICATION AND MAINTENANCE Valve Numbers D92-AP
MIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
DUCT TYPE AIR CONDITIONER
OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES AIR CONDITIONER DUCT TYPE English Deutsch
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184
EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49
Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
Leak Detection System
Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input